Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.
Municipal Corporation Tender
Other Consultancy Services
Consultancy Services
Eprocure
Opening Date14 Mar 2024
Closing Date29 Apr 2024
Tender Amount₹ 1,78,29,73,611 This is an estimated amount, exact amount may vary.
Costs
EMD
₹ 1,45,11,000Document Cost
₹ 1,77,000Tender Fee
Refer Documents
Summary
Request For Proposal Appointment Of System Integrator For Supply, Installation, Testing, Commissioning Maintenance Of Components
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_PMC_1034729_1Bid Award Id
ViewTender No
PMC/IT/26/2023-24Tender Authority
Municipal Corporation ViewPurchaser Address
-Website
http://mahatenders.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
PTZ Cameras: - H.265, Built-in IR with ~100m coverage, UL, IP True Day/Night Outdoor PTZ Dome Camera, 30x Optical Zoom & 12x Digital Zoom (or better), Color: 0.5 lx at 50 IRE, F1.2, AGC high or better & Black & White : 0.2 lx at 50 IRE, F1.2, AGC high or better, MPEG4/H.264/MJPEG or equivalent, PAL, Multi-streaming (Minimum 4 No. user-defined & configurable - different frame rate, bit rate, resolution, quality, and compression format) support, Electronic Image Stabilisation, AutoPan & Patrol Mode, Masking & WDR, IP 66 or better & vandal-proof.
110
-
-
ANPR Cameras: -2 MP or better ,IP True Day/Night Outdoor Fixed Box Camera, PoE enabled, ONVIF Compliant, low light visibility, clear visibility under rainy/cloudy/lightning conditions also. Immunity against EMI, RFI & lightning, 5-50 mm lens (Varifocal, Motorised Lens) or appropriate to capture minimum 3.5 meters lane width from a minimum height of 7 meters, Minimum 1/3'' progressive scan HD CMOS, Color: 0.5 lx at 50 IRE, F1.2, AGC high or better & Black & White : 0.2 lx at 50 IRE, F1.2, AGC high or better (without IR), Atmospheric Humidity: upto 95% RH at 38 deg C,Camera Housing: IP66, vandal-proof & of Stainless Steel / Aluminium material.,Glass: Heat Resistant Glass with KG3 or better coating, Multi-streaming (Minimum 4 No. User-defined & configurable - different frame rate, bit rate, resolution, quality, and compression format) support. The camera shall support 128 bit AES encryption.
100
-
-
PA Speakers: - Pressure-chamber IP Horn type loudspeaker; mounting bracket included, Suitable for outdoor areas; public announcements in open spaces with high noise levels & high people density; clearly audible (comfort hearing) at a radial distance of 30m at 500 angle (at surrounding noise level of ~80 to 100 db & max. people density of 5 per sq. meter) with sound level differential of minimum 20 to 30 db, Operating temperature shall be 55 deg C,
360
-
-
IR Illuminators: - Wavelength: ≥850 nm(Infrared), Illumination Range: minimum 50 mtrs, Environment Protection: IP66, Wattage – 80 watts per lane, Adjustable angle to appropriately focus at the number plate., Certifications: BIS, CE, IP 66, Connectivity – IP
100
-
-
Floodlights: -6,000 lumens and 50W power., IP65 waterproof and UV resistant., Adjustable Sensor - 'on' time, daylight lux level, and movement sensitivity can all be adjusted., Manual Operation - simple override option disables the sensor to keep lighting on when needed., Dependable - 50,000-hour rating and 3-year warranty., Motion Sensing to be undertaken by connected camera, Floodlight to be managed remotely,
92
-
-
Drones: -60 Minutes (Min.), Upto 1 KM, 100m, 10 to 70 Deg C, 10 m/s, Vertical (Takeoff as well as landing), a-Position Hold Mode,b- Autonomous Waypoint Navigation Mode (AUTO Mode),c- Emergency Return to Launch Mode, Li-Io 22000mAh Minimum, Model Should be DGCA Certified (Type Approval Certificate) ,UIN transferred in the name of purchasing organization ,Battery lifecycle certificate from NABL accredited Lab ,Support to customer in complying with the DGCA operational guidelines.
5
-
-
GPS based VTS Devices: - Hot Start- Maximum 10 seconds, Warm Start- Maximum 35 seconds, Cold Start- Maximum 50 seconds, Position horizontal +/- 10 meters or better, 15 0 deg C to 55 deg C, 8 V to 28 V (to be wired & drawn from vehicle battery) L+B+H should be less than 400 mm, Water resistant plastic metallic, IP 65 66 rated, vandal-proof & lockable
100
-
-
Mobile Surveillance Kits for emergency vehicles: - A modular, self supported, removable kit containing the following for For local and control room viewing with live streaming capability, 1 fixed camera, 1 PTZ camera Rugged NVR (Storage Capacity: 30 Days), Modem (with 5G Sim Card), Battery Pack, Installation rods & brackets, Rugged LED Monitors, Cables & accesories
5
-
-
Control Room
-
-
-
Server System: - Two socket x86-64 architecture, Silver 4310 Processor with 1 populated CPU scalable to 2 CPUs., Minimum 16 GB DDR 4 (in 8GB Modules) expandable to 128GB with minimum 32 DIMM Slots, 7.2K / 10K HDD (1.8TB x 3 numbers with RAID) or (Storage + System requirements + 50% spare space x 3 numbers with RAID) whichever is higher & shall be scalable., Minimum 4 x 1 Gbps NIC, RAID controller should support all HDD slots on the chassis; RAID controller should support RAID 1, 5, 6 HOT Pluggable, 5 USB Ports, 2 VGA, Serial Port , ODD, USB Keyboard, Mouse, Monitor, 2U rack Mounted, Dual redundant hot pluggable SMPS each capable of powering fully populated chassis, Redundant Fans, Internet+Antivirus Security packages, other Softwares as defined in this Tender & also those required to achieve the functional requirements & overall system integration., The server system shall be offered in N+N redundancy / HA mode
80
-
-
Video Storage System: - The system should be on a client-server architecture. The client application should be web based and run on all major operating systems such as windows and mac, The core application and database should be based on a clustered architecture to enable scalability. The cluster should scale to a minimum of 10 nodes., The operating system should be either Linux based operating system or on Windows Server 2019 or above, LDAP and Active Directory (AD) based authentication should also be supported, All standard file metadata should be automatically extracted and stored for easier search, Video-Codecs: XD CAM HD, DV Family, AVC Intra, MPEG2, H.264, H.265,Video Wrappers: MXF, MOV, DV, Mp4, Audio Formats: PCM / LPCM, MPEG Layer 1/2 Audio, AAC, HE-AAC, WMA, AMR, Raw, DV, All administration tasks of the proposed system should be supported on a web-based client,
2500
-
-
VMS: - VMS based on the open architecture which facilitates integration with other IT systems with the help of APIs (distributed free of charge), Windows / Unix / Linux, Event handling, motion detection, The VMS should be built on the open standards and shall be compatible with products from industry leading manufacturers, Recording- Should record audio / video, Continuous recording, by trigger (motion or alarm), by schedule, Distributed, fault tolerant database architecture, Video Search- Should be able to search video based on date / time, camera. Should have advanced / smart / quick search function, Should be able to export searched video to standard video codec (or with video player in case of proprietary format), Simultaneous viewing and recording from various cameras by multiple users, Multi Monitor viewing, Camera sequence mode, Register event, associated video, and alert operator on screen with audio, Show connection status of cameras, alert operator in case of connection failure to any camera
1119
-
-
IVA Software: -VMS based on the open architecture which facilitates integration with other IT systems with the help of APIs (distributed free of charge), Windows / Unix / Linux, Event handling, motion detection, The VMS should be built on the open standards and shall be compatible with products from industry leading manufacturers, Recording- Should record audio / video, Continuous recording, by trigger (motion or alarm), by schedule, Distributed, fault tolerant database architecture, Video Search- Should be able to search video based on date / time, camera. Should have advanced / smart / quick search function, Should be able to export searched video to standard video codec (or with video player in case of proprietary format), Simultaneous viewing and recording from various cameras by multiple users, Multi Monitor viewing, Camera sequence mode, Register event, associated video, and alert operator on screen with audio, Show connection status of cameras, alert operator in case of connection failure to any camera
831
-
-
ANPR & eChallan Software: - The System should automatically detect a vehicle in the camera view using video detection and activate license plate recognition., The System shall automatically detect the license plate in the captured video feed in real-time., The system shall perform OCR (optical character recognition) of the license plate characters (English alpha-numeric characters in standard fonts).,The System shall store JPEG image of vehicle and license plate and enter the license plate number into an SQL database along with date time stamp and site location details., System should be able to detect and recognize the English alpha numeric License plate in standard fonts and formats of all vehicles including cars, HCV, and LCV. In case of a non-standard number plate, the system shall register the image and allow the operator (with a rule based, authenticated and commented exception) to manually enter the number plate details. The system should identify the non-standard number plates automatically to provide an alert and enable an auto generation of challan., The system shall be robust to variation in License Plates in terms of font, size, contrast and color and should work with good accuracy., The system shall work with the same effectiveness in both day and night mode, The system shall detect the color of all vehicles in the camera view during daytime and label them as per the predefined list of configured system colors. The system will store the color information of each vehicle along with the license plate for each transaction in the database., The system shall have options to search historical records for post event analysis by the vehicle color or the vehicle color with license plate and date time combinations., The system should have option to input certain license plates according to the hot listed categories like “Wanted”, “Suspicious”, “Stolen”, etc by authorized personnel., The system shall enable easy and quick retrieval of snapshots, video and other data for post incident analysis and investigations., System should be able to identify the make of the vehicle coming in the field of view of the camera with good accuracy., System should be able to classify the vehicle into LMV, HMV and 2-wheelers. Challan Generation-a) The system should have facility to generate the challan using Challan generation software. The challan format shall be configurable and printable on a standard printer,b) The system shall be able to export all violation data captured including snapshots to the Challan Generation software being used by the state police / transport department, for further processing,c) The challan generation system shall provide standards reports in terms of challans sent based on a period, violations per license plate etc.
1
-
-
VTS Software: - Ability to provide the display of vehicle location on maps, logging of vehicle movements and provide the performance reports of the vehicle in a spreadsheet format.,The application shall allow for easy scalability by addition of new VTS units without any additional License requirements (unlimited license), The movement of vehicles can be played back at any time by choosing date and vehicle IDs. VTS Server sizing to consider this storage space requirement + 40% spare space., Load and calibrate maps of layered type, raster or any other type. incl Google Earth pro, Google maps, etc., Display vehicle on the maps by showing its icon in colour, identity code or alias name or any combination of them, Auto scroll to keep the desired vehicle in view., Zoom in/Out., Find selected vehicle by its ID or Alias name, Unlimited vehicle tracking all licenses & connectivity shall be in bidder’s scope., Alerts to indicate vehicle moving over specified area., Automatic detection of vehicle starting, passing speed limits., Multimodal alarms in the control room during any deviation Reporting of GPS messages in encrypted form to prevent unauthorized interception of messages, The VTS software should be hosted at the data centre,
1
-
-
Command & Control Application: -The system will provide a platform to integrate and manage disparate physical security systems, including but not limited to, video, communication, coordination, alarm management, disaster management, GIS etc. with one common interface.,This system should enable automation of security actions/processes as a part of the incident/disaster response management.,This system will support improved situation awareness and allow the end-user to more efficiently and more proactively report security issues.,Commercially available products that require minimal development to meet all of the requirements shall only be considered.,The C4I Software, VMS & IVA should work in an integrated manner as a single product & should preferably be from the same OEM.,Modular features (alarm, video, voice, etc) that allows users access to only designated modules,Modules are configured by personnel with administrator level access,Addition of "modules" or activity within modules will not obscure other modules,Additional systems can be added without the need to take down or reconfigure the rest of the system,Hardware neutral solution for major components such as servers,Hosting Hardware shall be commercially available with no customized components,Shall support redundant and/or clustered hardware to enable server failover capability. Should be VMware Ready,Supports SNMPv2 and SNMPv3 for network management,Integrates into Active Directory,System will be able to dynamically push alarm queue information using UDP or other connectionless protocol to a specified IP address or Active Directory FQN,Supports multicast connections.,Extensive logging features that report to a central management interface,All logs, alarm events, user actions will be logged to a management database using SQL,Web based or centralized management interface.,Access to logging, programming, administrative features is permissions based (ADS),Access to monitoring features is permissions based.,Permissions have a hierarchical structure.,Permissions in the C4I do not supersede permissions in integrated systems.,SNMP, OPC and ODBC connection options.
1
-
-
Disaster Management Software :-Effective Disaster Management (DM) requires an updated database of various assets within the city. Assets such as Government Offices, Emergency Services, Volunteers, various other governmental agencies external to the city, their physical locations, contact details, etc. are stored in the application. The DM application integrates with Geographical Information System (GIS) to locate the assets in graphical format on a map. The most important component of a DM application is Standard Operating Procedures (SOPs). SOPs can be developed for all kinds of disasters a city is prone to and kept in the database for easy reference. The DM application shall also have a database of disasters and SOPs can be linked to such disasters. So incase of a disaster, the Control Room operator can select the disaster type from the database and the linked SOPs can be fetched from the database for quick reference and action.
1
-
-
Enterprise/ Network Management System: - To ensure all the networked systems are delivered at the performance level envisaged, it is important that an effective monitoring and management system be put in place. It is thus proposed to have a proven Enterprise Management System (EMS) efficient management of the system, reporting, SLA monitoring and resolution of issues.,Various key components of the EMS to be implemented as part of this engagement are:• Server Monitoring System • Helpdesk System.,The solution should provide a unified web based console which allows role based access to the users.,Solution should provide fault & performance management of server side infrastructure and should monitor IP\SNMP enabled devices like Routers, Switches, PA System, Sensors, etc. Proposed Network Management shall also help monitor key KPI metrics like availability to measure SLA’s. Following are key functionalities that are required which will assist administrators to monitor network faults & performance degradations to reduce downtimes, increase availability and take proactive actions to remediate & restore network services.,- Proposed solution must automatically discover manageable elements connected to the infrastructure and map the connectivity between them. Solution should provide centralized monitoring console displaying network topology map.,- Proposed solution should provide customizable reporting interface to create custom reports for collected data.,- System must use advanced root-cause analysis techniques and policy-based condition correlation technology for comprehensive analysis of infrastructure faults.,System should be able to clearly identify configuration changes and administrators should receive an alert in such cases,- Tool should integrate with network performance management system and support operating system monitoring for various platforms supplied as part of this Project.,- Tool must provide information about availability and performance for target server nodes.,Tool should be able to monitor various operating system parameters such as processors, memory, files, processes, file systems, etc. where applicable,- Proposed helpdesk solution must provide flexibility of logging, viewing, updating and closing incident manually via web interface for issues related to surveillance project.,- Helpdesk system should provide incident management, problem management templates along with helpdesk SLA system for tracking SLA’s pertaining to incident resolution time for priority / non-priority incidents.,
2
-
-
Core Switches: - Minimum 12*Ports 10/100/1000 Base-T ports, 12*1 Gbps Single Mode ports and additional minimum 2*10 Gbps SFP+ slots, All ports can auto-negotiate between all allowable speeds, half-duplex or full duplex and flow control for half-duplex ports., 1 *RS232/1*RJ-45 Serial Console port, 1* USB port for loading and taking backup of firmware's, 19” Rack Mountable stackable switch, The switch should have dedicated stacking port separate from uplink ports with 40 Gbps of stacking bandwidth,Jumbo Frame- Should support jumbo frame. (9216 Byte), 1. Should have IPV4 & IPv6 support from day one, 2. Support 802.1D, 802.1S, 802.1w, Rate limiting,
4
-
-
Unified Threat Management Devices: - Firewall appliance should have at least 6 x 10/100/1000 GE interfaces along with 4 x GE SFP slots.,The Firewall should have integrated SSL VPN solution to cater minimum 500 SSL VPN concurrent users. The proposed system should support IPsec VPN The device should support at least one management interfaces to manage the firewall. Firewall should support IPv4 & IPv6 dual stack functionality Firewall should support user/admin authentication Firewall should support Nat66 (IPv6‐to‐IPv6) and Nat46 (IPv4‐to‐IPv6) functionality, NAT66 Firewall should support static, dynamic and multicast routing protocol The device should support redundant power supplies Should support stateful failover of sessions in Active/Standby & Active/Active or clustering mode. Firewall should support creating access polices on the basis of IPv4, IPv6 objects, protocols, ports etc. Web Filtering: Keyword, Block Java applets, cookies, ActiveX, Block malware, phishing, pharming URL. Intrusion Prevention System (IPS): should be able to mitigate attacks like FTP Attack, HTTP Attack, DNS Attack, ICMP Attack, TCP/IP Attack, DOS and DDOS Attack, TelNet Attack.,Signatures, IPS Policies, Automatic real‐time updates, Protocol Anomaly Detection.,The device should be manageable using standard protocols like HTTP, SSL, SSH, SNMP etc..,The device should be able to send the event logs, alarms, etc. to the third‐ party tool.,The device should be hardware based and should be supplied with Indian Standard power cables.,Proposed device should also perform activities like Intrusion prevention, IP Reputation, URL filtering, Antivirus from day one with required Licenses and support for 5 years., UTM Firewall, IPS (with 3 years signature updates) renewable every year by bidder until completion of CAMC (shall be considered by bidder as part of CAMC scope).,To be IEEE compliant.
4
-
-
Routers: - The back‐plane capacity of Router should be minimum 100Gbps & forwarding performance of 80 Mpps packets per sec of 64 bytes packet. The performance is considered with IPv4 & IPv1., Interface Requirement: 16 X 1 Gig Base SFP interface and 4 X 10Gig interface (The optics should be populated from day one) and Chassis should have atleast 3 free main slot (not dauther slots) to scale in future to support additional 8 X 10Gig interface or 60.,X 1 Gig interface in future., The Router should have High Availability Features: Non-Stop Routing, Graceful Restart, In Service Software Upgrade, hitless software upgrade,802.1ag, MC-LAG, BFD for IPv4 and IPv6, VRRP. Protocol: DHCP, IP Multicast, PIM SM, PIM SSM, IGMP, MLD, RP, IS-IS, HQOS, LDP, MPLS, MPLS FRR, L2 VPN, L3 VPN, VPLS, Diff Serv TE, RIP V 2, OSPF, BGP,NAT, Router should have IPv4, IPv6 and QoS Classification. Should have 3M IPv4 and 2M IPv6 routing entries per system., Network Management: SNMP v2 and upgradable to SNMP V3, Console management access, NTP or SNTP, Certification: Router should be NEBS certified and EAL 3/NDPP certified under Common Criteria.,
4
-
-
Smart Rack: -4-6 KW IT load per Rack Integrated DC with minimum 210U available for IT equipments. The total rack space shall be calculated by the bidder based on its proposed equipment offering & sizing. 30% extra redundancy in available slots (U) should be considered. A detailed rack drawing should be provided as a part of the technical proposal, Compliant to Tier 2/3 guidelines for Data Center, N + N redundancy for cooling system , Fire Detection & Suppression, PDU, Electrical DB, Water leakage detection and Monitoring system with Auto door opening, providing high availability of each equipment for set of 2 Rack Integrated DC., DB panel mounted inside cabinet with all internal cabling integrated into the same. Adequate precaution and compliances to be taken care for sizing/ratings of cables and switchgear inside Rack., Interface Requirement: 8 x 10/100/1000 Base-T Copper Ports, 4 x 10 GB 10G SFP ports from day 1 and support for addition of 2 x 40G SFP ports. Dedicated Management and Sync Ports, Rack mount on line double conversion UPS of 10 KVA up to 94% efficiency at full load and 0.8 output power factor. UPS to be provided with External battery bank with SMF batteries for 30 min. backup on 100% IT load with required rack mount accessories. UPS should follow all standards including UL/CE, ISO 9001 and ISO 14001, The cooling system shall be zero U rack based type with horizontal uniform cold air distribution with N+N redundancy.,It shall be highly efficient, closed loop circuit, “front to back” cooling solution up to 7kW per cooling unit with ambient temperature range +10° C to +50° C .,The cold air distribution shall be lateral, uniform from 1U to 42U in front of the 19” equipment for efficient cooling.,There shall be no loss of vertical “U” space inside the 19” Rack while mounting the equipment.,Indoor operating temperature range: +18°C to +29°C.,Indoor Unit Noise Level:49 dBA,Fans: Low noise axial fans with high air flow, high static head with minimum losses, Sturdy frame section construction, All profile edges are radiuses. Removable top & Bottom cover with Cable entry provision. Frames should be bayable, scalable and modular, High density with 42U as standard, complete with shelf, cable manager & blanking panels with PDU. Each Rack frame should be 42 U 19'' mounting type with minimum 2000 mm (Height) x 600 or 800 mm (Width) x 1200 mm (Depth). Rack design should be sturdy frame section; corners stiffened with welded MS die cast. Rack to be provided with all basic accessories like, blanking panels, baying kit, sliding keyboard tray, vertical cable manager as well as horizontal cable manager, earthing copper strip with insulators, PDU 32 amp vertical mounting with IEC type socket with 12 nos of IEC C13 Sockets & 4 nos IEC C19 Socket with 2.5 mtr power chord with 32A MCB. Each rack shall have minimum two such PDU's
2
-
-
Control Room Infrastructure: -Floor finishing with Anti-static, fire resistant laminated solid resilient unbreakable and homogeneous flexible quartz reinforced PVC Vinyl tiles composed of 100% vinyl from face to back with alkaline resisting colour pigments and other plastic compounds in different shades and designs and in different sizes and thickness and shall conform to IS : 3462 or its Equivalent British Standard.,Quantity: Max Approx. 100 Sqm,False Ceiling: The Data Center, Monitoring Room & Conference Area should have False Ceiling confirming to the following specifications: It should be of Armstrong Mineral Fibre board 16mm thick and 600mm x 600mm Dune RH 99 tile with Microlook edge in true horizontal level suspended on locking Armstrong Grid system made of Hot Dip Galvanized steel section powder coated as per manufacturers specification including making opening for electrical & air conditioning fitting complete as required. The tiles are to be installed on Armstrong 15 mm grid system having fire rating of 60 minutes as per BS 476 / 23 of 1987 with following properties : Noise Reduction Co-efficient (NRC) of 0.50, Sound Attenuation of 32 db, Light Reflectance of 83%, Thermal Conductivity K-0.052 - 0.057 ,Weight of 4.0 kg/m2 and Humidity Resistance of RH - 99. Quantity: Maximum 50 Sqm. Make: Armstrong / India Gypsum / AMF/ Equivalent.,Cladded Glass / toughened glass shatter-proof window.,The existing walls & roof shall be painted in plastic/velvet.,Make: Asian Paints / Nerolac / Berger /Equivalent.,Glass walls shall be provided with sun-reflecting opaque films. Make:3M / equivalent.,Partition, wherever required, Quantity: Max. 20 Sqm As-required. Doors with all the hardware to be provided. Type of partition & material specs to be provided.,Internal electrification, data/audio/video cabling jobs like point wiring, internal Lighting, Distribution boards, IOs etc.; As per the relevant IS or British Standards for data center with 100% redundancy,All electrical lighting shall be of the LED type.,
2
-
-
Workstations: - Intel Core I-7 Processor, latest generation, Min. 8GB, DDR-3 or better, Minimum 4 GB onboard video memory, 500 GB or better; SATA @ Min. 7500 RPM – 8MB Cache, Dual Port Gigabit Ethernet, Auto Negotiating Ethernet controller, Windows 8 Professional (64 bit) / Latest Windows OS / Linux, 21” LED, Ultra HD Display, Shall have built-in / external speakers, Antivirus & Internet Security softwares, Industrial Grade Station suitable for 24 x 7 x 365 operation. Optical Disk Drive, All USB Storages shall be password protected for access, keyboard, mouse, other Software as defined in this Tender & also those required to achieve the functional requirements & overall system integration. Ability to extract user specific video & alarm data to external DVD/USB storage devices as MPEG4/AVI formats with a default digital certificate for signing the exported recordings, alarms & audit logs. An additional utility shall be provided to display the exported recording, view the audit log/alarms and verify the digital signatures. A visual indication shall be provided to whether the exported recording and audit log / alarms have been altered/tampered with. MIL-STD-1275 Surge & spike protection. To be free from EMI, RFI, VHF, Mobile disturbances.
20
-
-
Videowall: -Display Controller to control upto 24 panels, with required outputs, in any matrix combination; Capable of taking universal/multiple inputs (10) & outputs for video/data along with necessary wall management software; Dual Gigabit Ethernet Ports with support for additional adapters; 4-DVI-D/HDMI Outputs; Support for Full HD resolution at full frame rate for all panels; Quad Core 64-bit processor with 4GB RAM; 1 TB HDD, Support for Multiclient/console; Software enable user to display, multiple sources up to any size and anywhere on the display wall; auto source detection; Should support for Video, RGB, DVI, Internet Explorer, Desktop Application and Remote Desktop Monitoring Layouts; Built-in auto-layout scheduler; Multiple concurrent client support., Very narrow & black bezel (1mm) CCTV Monitor suitable for continuous (24x7x365) use with MTBF of more than 50,000 Hrs; Contrast Ratio 10000:1; Pixel Density 40 dpi; Luminance 700cd/m2 , Min. 55” LED (2x6 Matrix), 1920x1080 or better, Mounting kits, Brackets & Supports to suit installation requirements., UL, FCC, CE
2
-
-
PTZ Controller: - Fully functional dynamic keyboard controllers with joystick, Controls all pan / tilt and zoom functions, Control up to 255 units from a single keyboard, Many preset options and advanced tour programming, Compatible with DN-PTZ camera,Wired keyboard control operation of PTZ & other functions for weatherproof dome cameras.,Pan / Tilt / Zoom Protocol Languages Supported- Selectable.,Selectable 1200 bps / 2400 bps / 4800 bps / 9600 bps / higher.,Dynamic joystick for smooth camera movements, preset location option for quick access to frequently monitored Areas. All joystick movements shall also be possible using external mouse attached to the decoder Station.
4
-
-
Microphone / PA Controller: - IP Master Control Desk to work as a console or built in control desk with zone selector, announcement station & operator station for receiving the calls made from the help desks; shall be able to do switching & control functions; multifunction, multicolored, user-configurable LED display for indicating operating states; shall be able to extend/cascade via modules with additional functions. Built-in Minimum 128x64 pixel LCD/LED display. Control Desk with Microphone & Speakers & all the features of the Master Control Desk through software interface. All other relevant specs same as that for the Master Control Desk., Dashboard for the IP-based public address system shall also be available.
4
-
-
UPS at Control Room: - The UPS should be of 30 KVA capacity or as required as per the power load calculations of the bidders, whichever is higher. Bidder to provide power load calculations., Technology : IGBT (Insulated Gate Bipolar Transistor) PWM technology True ONLINE. Capable of high frequency application, high switching speed., The bidder shall furnish proposal for UPS systems with parallel redundant configuration as per capacity as indicated, Configuration : Modular; N + 1 Configuration (Total net demanded Capacity with 25% Spare ), Consider the voltage level : Input voltage : 415 V,3phase +/- 10%, Output voltage : 415 V, 3 phase +/- 2%,
2
-
-
Diesel Gen Set: -Auto Starting DG Set mounted on a common base frame with AVM (Anti-Vibration) pads, residential silencer with exhaust piping, complete conforming to ISO 8528 specifications and CPCB certified for emissions, Radiator cooled, multi cylinder, 1500 RPM diesel engine, with electronic/manual governor and electrical starting arrangement complete with battery, conforming.,to BS5514/ ISO 3046/ IS 10002, High Speed Diesel (HSD), Self-exciting, self-regulating type alternator rated at 0.8 PF or better,415 Volts, 3 Phase, 4 wires, 50 cycles/sec, 1500 RPM, conforming to IS 4722/ BS 5000, Windings of 100% Copper, class H insulation,Protection as per IP 23, AMF Panel fitted inside the enclosure, with the following:,It should have the following meters/indicators.,§ Incoming and outgoing voltage.,/ Current in all phases.,§ Frequency, KVA and power factor.,§ Time indication for hours/minutes of operation.,§ Fuel Level in fuel tank, low fuel indication.,§ Emergency Stop button.,§ Auto/Manual/Test selector switch.,§ MCCB/Circuit breaker for short- circuit and overload protection.,§ Control Fuses, Earth Terminal.,Any other switch, instrument, relay etc. essential for Automatic functioning of DG set with AMF panel,It should be sufficient & suitable for containing fuel for minimum 12 hours continuous operation, Complete with level indicator, fuel inlet and outlet, air vent, drain plug, inlet arrangement for direct filling and set of fuel hoses for inlet and return.
2
-
-
Field Elements
-
-
-
Field Industrial Switch: - Layer-2 Managed POE+ Industrial Switch with 8 Port 10/100/1000 Mbps FE Switch with 2 1G Combo ports (IPv6 Compliant). 1U / 2U Rack Mounted. To be IEEE802.3 compliant, 6 Gbps, 4 Mpps, 0˚ C to 75˚ C
389
-
-
Outdoor Junction Box: - Pole and cabinet to be of same Material of construction which shall be Hot dipped Galvanized Steel. Thickness of the material to be designed to withstand the suitable payload., The top of pole and cabinet to be designed to prevent accumulation of rain water and dust, To help prevent injuries, all fabricated material and added components must be made smooth to the touch, Provisions shall be made for adequate cross flow ventilation. The exhaust air opening in pole and external air inlet in cabinet shall be large enough to allow sufficient air exchange. Both openings shall be filtered on the inside and covered with shrouds on the outside. The external shrouds shall be designed to be nonrestrictive to the airflow, louvered on the bottom and extend a minimum of one inch below the opening in the cabinet wall. The air filters must be designed for easy replacement.
390
-
-
LIUs & Networking Accessories: - LIU should be provided for terminating the optic fiber cables. It shall provide minimum bending radius and the splice trays shall function as a splice cover for pigtail splicing. It shall be made of aluminum with powder coating in compliance with latest industry standard. Cable glands shall be provided for secured anchoring of incoming cables. Rubber grommets shall be provided at the cable entry point for tight sealing. The splice tray shall be made of ABS materials. 12/6 Port (All OFC cores to be terminated)
389
-
-
Camera Poles with Arms:- 1. Hot dip galvanized steel pole with minimum 5 mm thickness. Thickness of the material to be designed to withstand the suitable payload. The top of pole and cabinet to be designed to prevent accumulation of rain water and dust.,Pole would be fixed on an adequate and strong pre-cast. 2. foundation to withstand city weather conditions and wind 3.speed of 150 km/hr.,Casting of civil foundation with foundation bolts to ensure 4.vibration free (video feed quality should not be impacted 5.due to wind in different climatic conditions.) Expected. 6.foundation depth of minimum 100 cm or better. M20 concrete shall be used. Guard against corrosion and soil erosion should be taken care of. 7.The pole foundation shall be designed as per industry standard. All civil work necessary for the same shall be in the scope of the vendor. The entire area where foundations are made shall be reinstated to the original condition, without any exception.,Separate hole for cable entry on top of pole for Camera connection to be provided. G.I. Conduit threaded elbow to be provided which shall be pointed downwards to avoid any water seepage inside pole through cable entry.,Cable entry inside the pole to be designed from the bottom of the pole through the base frame and foundation.,All cable/ ducts entries should be from the foundation of the pole. The CAT 6 or power cables from the cabinet to the camera should also be flown from inside the pole. No cable/ duct shall be installed /noticeable on the pole.,Base frame shall be designed to take the load of pole, camera, camera accessories and additional 100 kg. Base frame to be supplied by vendor.,All vents to be sealed to ensure minimum IP55 sealing.,Height of the pole shall be as per requirement of the location varying from 7 m to 10 m.,Gantry construction and height should be such to allow unimpeded access to vehicles as per NHAI guidelines. The gantry specifications shall be as per the pole, with the horizontal section to withstand a span of upto 11 m, without affecting structural integrity.,The foundation and the pole / gantry should be certified by a structural auditor after the installation. Arms length approx. 600-800mm.
488
-
-
Gantries: - Hot dip galvanized steel pole with minimum 5 mm thickness. Thickness of the material to be designed to withstand the suitable payload. The top of pole and cabinet to be designed to prevent accumulation of rain water and dust.,Pole would be fixed on an adequate and strong pre-cast foundation to withstand city weather conditions and wind speed of 150 km/hr.,Casting of civil foundation with foundation bolts to ensure vibration free (video feed quality should not be impacted due to wind in different climatic conditions.) Expected foundation depth of minimum 100 cm or better. M20 concrete shall be used. Guard against corrosion and soil erosion should be taken care of. The pole foundation shall be designed as per industry standard. All civil work necessary for the same shall be in the scope of the vendor. The entire area where foundations are made shall be reinstated to the original condition, without any exception.,Separate hole for cable entry on top of pole for Camera connection to be provided. G.I. Conduit threaded elbow to be provided which shall be pointed downwards to avoid any water seepage inside pole through cable entry.,Cable entry inside the pole to be designed from the bottom of the pole through the base frame and foundation.,All cable/ ducts entries should be from the foundation of the pole. The CAT 6 or power cables from the cabinet to the camera should also be flown from inside the pole. No cable/ duct shall be installed /noticeable on the pole.,Base frame shall be designed to take the load of pole, camera, camera accessories and additional 100 kg. Base frame to be supplied by vendor.,All vents to be sealed to ensure minimum IP55 sealing.,Height of the pole shall be as per requirement of the location varying from 7 m to 10 m.,Gantry construction and height should be such to allow unimpeded access to vehicles as per NHAI guidelines. The gantry specifications shall be as per the pole, with the horizontal section to withstand a span of upto 11 m, without affecting structural integrity.,The foundation and the pole / gantry should be certified by a structural auditor after the installation.
100
-
-
Surveillance Signage: - Stainless steel / Aluminum Sheets, Approximately 600*400 mm with frame and fixtures for pole/wall mounted, Minimum 6mm, All text and logos to be silkscreen printed and then finished with protective quoting.,Content and design to be discussed with selected bidder.,The surveillance signages shall be in 2 languages (Hindi & English). The content shall be decided later.
1000
-
-
Last mile including cable, conduit, trenching, refilling & resurfacing (data and electrical)
-
-
-
1. Cat6 Cable (with Casing/caping/ PVC Conduit):- Cat.6, U/UTP, AWG23 cable. 100 Ohm impedance. Data transmission frequencies of up to 450 MHz; metal-free ; flame-retardant; ISO/IEC 11801 ed. 2.2; IEC 61156-5 2nd ed.; EN 50173-1; EN 50288-6-1; TIA 568-C.2; Fire rating: IEC 60332-1 Compliant. 2.Supply of UTP CAT 6 Cable shall include cabling from Switch to individual outlets in Casing Capping/PVC Cable Duct/ Flame resistant mechanically protective Conduit as per requirement, supply & installation of Information Outlet at the equipment end, factory crimped patch cords of required length at both the patch panel end as well as equipment end, including material, fittings & fixtures, screws etc. Cable lengths & CAT-6 cabling with connections/PoE/extenders to ensure that collision detection mechanism shall work as expected & timeout errors are eliminated. 3.For Outdoor: GI round wire armoured cable shall be used.
75000
-
-
OFC Cable:-24 core, Uni-tube, Armoured, Direct Burial 62.5 μm /125 μm MM FO Cable Four-Fibre, Uni-tube Construction, Gel Filled, Multimode Optical Fibre Cable (OFC) With 4 Nos. 62.5/125 Microns Colour Coded Fibres As Per G.651 Standards, Eccst Armour, Embedded Steel Wire / FRP Strength Members, Water swellable/Water Blocking Tape & Outer UV Resistant And Fire Retardant LSZH Sheath Having Anti-Termite And Anti-Rodent Properties, Suitable For Direct/Duct Burial
12000
-
-
1. Power Cable with Conduiting, DBs & Accessories from Eletrical existing DB to all JBs :-3-Core, 2.5 sq mm, with annealed electrolytic multistranded copper conductor with resistance less than 8.2 7.41 Ohm/Km; Fire retardant, low smoke, low toxic, PVC black outer sheath meeting BS-5308, insulated (min 0.3 mm inner+1.8 mm outer sheath) Rated for 1.1KV, For Outdoor: GI round wire Armoured with galvanized steel wire with 90%+ coverage; IS 694:1990 reaffirmed 1995 or latest compliant. 2.Cable drum lengths shall be adequately considered to minimise joints. 3.Higher Cable sizes (if required) to meet the distance/higher current consumption requirements (from sources upto 500 mtrs away) shall be considered by the bidder instead of the 2.5 sq.mm cables indicated, at no extra cost. 4.Shall prevent moisture ingress even due to outer sheath damage / poorly sealed joints. Cable shall be suitable for direct burial also. 5.Cable shall have its running meter stamped/marked every 1 mtr (to be resistant to damages caused by cable pulling. 6. activities). UV resistant outer insulation of Black colour.
30000
-
-
Trenching:-This will comprise laying (all labour for digging, refilling) of cables in a structured format (using appropriate quality of HDPE Pipe or GI Pipe of 32 mm ID). All the onsite civil, electrical and mechanical works required in terms of the Trenching, refilling, laying, installation and commissioning of the various components at every location will be in the scope of the SI.
30000
-
-
Single Phase energy meter:- Supplying and erecting static energy meter with 240V 50 Hz. AC supply 5 to 30 A, ISI mark, accuracy class 1.0 with backlit LCD display, (measuring and display kWh, kVAh, V,I,PF, frequency, kW, kVA, six months history of Energy & MD in kW & kVA) with transparent hinge type box complete erected on polished teak wood board duly wired with required size of weather proof PVC wires duly tested by electric supply company
300
-
-
Three Phase energy meter:-Supplying and erecting three phase 10 to 60 A net meter DLMS complianceof accuracy class 1.0, 3 x 240V, 50 Hz, with backlit LCD display, optical port and RJ 232 port (measures import kWh, kVAh, export kWh, kVAh, Net kWh, kVAh,V, I, kW, 6 months history of energy) with wiring connections and mounting hardware on provided panels complete with calibration certificate from manufacturer.
100
-
-
Power Cable For Energy meter:-Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 10 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
20000
-
-
MCB:-Supplying and erecting 6 to 32 A, 10kA, SPMCB suitable to fix in 1 module of modular switch in provided box complete & duly concealed with necessary material and connected.
400
-
-
8 module plate: -Supplying and erecting PVC Surface modular double mounting plate 8 module complete duly erected.
400
-
-
Field UPS: - Line Interactive UPS of sufficient power rating (Min. 500VA) to provide uninterrupted & conditioned power supply to field cameras & active networking components, Maintenance-free sealed Lead-Acid battery with suspended electrolyte: leak-proof, 30 minutes with SMF batteries at half-load
371
-
-
Local Monitoring Rooms (Local Police Stations): - It is proposed that 6 local monitoring centers be setup alongwith the infrastructure, bandwidth and required IT infrastructure, for the viewing of local cameras at respective police stations, Control Room Infrastructure for LCR of approx. area 18 sqm. with wall painting, Operator Workstation, chair, Partition, False Ceiling, LED Lighting, Electrical & associated cabling work as per the standard practices.
6
-
-
Installation & Commissioning
1
-
-
Additional Components (As proposed by the Hon., CP, Navi Mumbai)
-
-
-
Facial Recognition System (with additional computeing & storage hardware)
100
-
-
· Speed Detection Cameras: - The system shall have a video-based speed violation detection feature that uses a special camera (minimum specifications of ANPR camera) to capture the license plate and the vehicle speed. The system shall provide the ability to set different speed limits for different categories of vehicles and time periods. The feature shall have the functionality to prove the vehicle speed using a simple on-screen tool. In case of a speed violation, the system shall generate a violation alert and the operator shall be able to review the captured event.,The speed detection software system shall be certified by any government accredited laboratory for speeds from 40 KMPH to 200 KMPH with variation of less than 2% at various speed thresholds. The test shall have been performed on a third-party camera., The system shall have Average Speed detection functionality for a control section / corridor within the city. All vehicles passing through the control section at a speed greater than a determined speed limit shall be detected as a violation. It shall be possible to create multiple points within a long corridor for determining the average speed,IP True Day/Night Outdoor Fixed Box Camera, PoE enabled, ONVIF Compliant, low light visibility, clear visibility under rainy/cloudy/lightning conditions also. Immunity against EMI, RFI & lightning., 5-50 mm lens (Varifocal, Motorised Lens) or appropriate to capture minimum 3.5 meters lane width from a minimum height of 7 meters.
50
-
-
Additional Cameras
-
-
-
Outdoor Fixed Cameras: - CMOS Sensor –progressive scan 5 MP or better, 5 to 50 mm CS mount, Colour : 0.5 lx at 50 IRE, F1.2, AGC high or better, Black & White : 0.2 lx at 50 IRE, F1.2, AGC high or better, Multi-streaming (Minimum 4 Nos user-defined & configurable - different frame rate, bit rate, resolution, quality, and compression format) support, Multi-streaming (Minimum 4 Nos user-defined & configurable - different frame rate, bit rate, resolution, quality, and compression format) support, PAL, MPEG-4, H.265, 0°C to 50°C (Operating)
166
-
-
Panoramic Cameras:- 5x4MP; 30FPS at full Resolution, 180˚ (horizontal) 30˚(vertical) and ~182˚ (diagonal), Fixed 6 mm, DC-Iris, Minimum 5-megapixel progressive scan HD CMOS; Should have minimum 4 lenses/sensors,
16
-
-
PTZ Cameras: - H.265, Built-in IR with ~100m coverage, UL, IP True Day/Night Outdoor PTZ Dome Camera, 30x Optical Zoom & 12x Digital Zoom (or better), Color: 0.5 lx at 50 IRE, F1.2, AGC high or better & Black & White : 0.2 lx at 50 IRE, F1.2, AGC high or better, MPEG4/H.264/MJPEG or equivalent, PAL, Multi-streaming (Minimum 4 No. user-defined & configurable - different frame rate, bit rate, resolution, quality, and compression format) support, Electronic Image Stabilisation, AutoPan & Patrol Mode, Masking & WDR, IP 66 or better & vandal-proof.
22
-
-
ANPR Cameras: -2 MP or better ,IP True Day/Night Outdoor Fixed Box Camera, PoE enabled, ONVIF Compliant, low light visibility, clear visibility under rainy/cloudy/lightning conditions also. Immunity against EMI, RFI & lightning, 5-50 mm lens (Varifocal, Motorised Lens) or appropriate to capture minimum 3.5 meters lane width from a minimum height of 7 meters, Minimum 1/3'' progressive scan HD CMOS, Color: 0.5 lx at 50 IRE, F1.2, AGC high or better & Black & White : 0.2 lx at 50 IRE, F1.2, AGC high or better (without IR), Atmospheric Humidity: upto 95% RH at 38 deg C.,Operating environment Temperature: 0 to 55 deg. C.,Glass: Heat Resistant Glass with KG3 or better coating, Multi-streaming (Minimum 4 No. User-defined & configurable - different frame rate, bit rate, resolution, quality, and compression format) support. The camera shall support 128 bit AES encryption.,Additional Storage & Computing Requirement.,AI Based Analytics.,DC Set-up at CMS
20
-
-
Additional Storage & Computing Requirement
-
-
-
AI Based Analytics
1
-
-
DC Set-up at CMS
1
-
-
Vehicle Counting Cameras: - The Cameras shall be mounted on a gantry & shall be able to intelligently identify & classify objects & vehicles based on various parameters, including size, colour (e.g. two-wheelers, cars, HMV, Containers etc). The system shall also be able to provide a graphical analysis of the traffic & provide alarms against threshold crossing.,IP True Day/Night Outdoor Fixed Box Camera, PoE enabled, ONVIF Compliant, low light visibility, clear visibility under rainy/cloudy/lightning conditions also. Immunity against EMI, RFI & lightning., 5-50 mm lens (Varifocal, Motorised Lens) or appropriate to capture minimum 3.5 meters lane width from a minimum height of 7 meters., Color: 0.5 lx at 50 IRE, F1.2, AGC high or better & Black & White : 0.2 lx at 50 IRE, F1.2, AGC high or better (without IR).,
10
-
-
Mobile Surveillance Kits for emergency vehicles: -A modular, self supported, removable kit containing the following for For local and control room viewing with live streaming capability, 1 fixed camera, 1 PTZ camera Rugged NVR (Storage Capacity: 30 Days), Modem (with 5G Sim Card), Battery Pack, Installation rods & brackets, Rugged LED Monitors, Cables & accesories
5
-
-
CAMC charges
-
-
-
Post warranty CAMC charges for 1st year
1
-
-
Post warranty CAMC charges for 2nd year
1
-
-
Post warranty CAMC charges for 3rdyear
1
-
-