Mumbai Port Trust Tender

Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.

Mumbai Port Trust - MBPT Tender

Works
Eprocure
Opening Date23 Sep 2020
Closing Date15 Oct 2020
Tender AmountRefer Documents 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Disconnecting and removing the burnt out portions/parts including interconnection bus-bars, meters, wiring, CTs, etc. of 2 Nos. Incomer and Bus-Coupler ACBs,1250 amps and 1 No. outgoing 600 amps ACB from the existing M.V. Panel and closing/covering the exposed portion of bus-bars of the cabins using 5mm thick Bakelite sheet to instruction.

1

-

85000

... More
Disconnecting and removing the existing ammeter, CT, selector switch, wiring, fuses, etc. from the existing circuit breaker’s individual cabin and supplying and providing 1 No. Ammeter 0-400 Amps, single phase, digital, 96 sq.mm, class 0.5 accuracy with Current Transformer, ring type bar primary 400/5A,10VA, class 0.5 accuracy and selector switch, complete with cleaning the operating parts/contacts of the ACB with CTC/contact cleaner, etc. control wiring using 2.5 sq.mm PVC copper conductor wire, suitable insulated connector blocks for connecting control wires, fuse protection and testing and putting the existing circuit breaker in service to instruction as required.

6

-

41500

... More
Providing and fixing tinned copper bus-bars (R, Y, B) of size 60x10 mm (approx..) for phases and 60x5mm (approx..) for neutral to serve as bus coupler in place of burnt out ACB, complete with suitable capacity epoxy insulated supports, heat shrinkable PVC sleeves for bus bars, fixing bolts, nuts and washers, etc. in all respect for coupling the 2 sections of bus-bars as required.

1

-

33500

... More
Carrying out the work of checking and cleaning the male and female contacts of the Isolator with CTC/ contact cleaner, operating mechanism of the unit, cabin, etc. and testing and putting the isolator in service condition to instruction as required ( The item rate shall include the work of removing the existing fuse unit, checking the fuses, cleaning the fuses with contact cleaner and re-fixing the fuses as required).

5

-

25400

... More
PART-B

-

-

-

... More
Disconnecting and removing the old control wiring, indicating lamps, etc. from APF Panel No.2 and providing new control wiring using 2.5 sq.mm S.C. PVC copper wires, new indicating lamps, connector blocks, etc., cleaning the terminals of the capacitor, contactor units, checking the interconnection system and repairing and rectifying the fault if any and testing and re-commissioning the APF panel No.2 to instruction as required.

1

-

105000

... More
Disconnecting and removing the existing defunct battery charger along with incoming & outgoing cables from charger panel at SS12 for providing and accommodating new battery charger under item at Sr.No.9 below and shifting the dismantled battery charger panel to SMRS and handing over the same to MbPT to instruction.

1

-

10800

... More
Manufacture, supply, delivery, installation, testing and commissioning of 110 Volts,160 AH, 25 amps, Float cum Boost battery charger in sheet steel enclosure with IP 42 protection, floor mounting, bottom cable entry with gland plate, complete with all essential components viz. rotary switches, air breaker contactors, fuse bases with fuses, power and control terminals, transformer, rectifier, ammeters, voltmeters, MCB units, indicating lamps, etc. as per manufacturer’s technical specifications, manual, etc. as required(Approved Make: Electronic Systems, Vadodara or any other approved makes).

1

-

296000

... More
Handling, shifting of 9 Nos. 12 Volts,160AH,6EL160 type, Exide make batteries from SMRS, Indira Dock to SS12 and installing the same at SS12 complete with suitable floor mounting, free standing M.S. angle frame work of size 2mx0.6mx0.85m height(approx..) to accommodate 9 Nos. 12 volts batteries, fabricated out of 75x75x5mm (approx.) M.S. angle with 25mm(approx..) thick teak wood plank on top of the stand with fixing arrangement for fixing/installing the batteries in series, interconnecting the( + and - )terminals of batteries by using appropriate size of insulated tinned copper bars/links or using appropriate size of PVC/PVC sheathed or sleeved copper conductor wires with copper lugs, connecting the end terminals of battery bank, testing and commissioning the battery bank to instruction. The M.S. angle stand shall be earthed using G.I. strips of size 25x 3mm (approx.), painted with one coat of red oxide and two coats of grey paint including planing the wooden plank and polishing as required (Note: 9 Nos. new batteries of 12 volts each will be issued by MbPT free of cost from SMRS site.)

1

-

74000

... More
Checking the working of existing float cum boost battery charger, incoming & outgoing supply, control wiring, all electrical& electronic components of the charger and repairing the same by supplying and providing the required components/materials, if any, testing and re-commissioning the charger to instruction as required.

1

-

45000

... More
Supply and delivery at site of 1100 Volts Grade, L.T. power cable of size 4 core x 16 sq.mm with stranded copper conductor, XLPE/PVC insulated with one layer of galvanized round steel wire / strip armoured and PVC outer sheath and cable shall be conforming to IS 1554(Part-I)/ IS: 7098 (Part I) - 1988 (amended up to date) and bearing ISI mark.

25

-

1320

... More
Supply and delivery at site of 650/1100 Volts Grade, L.T. control cable of size 2 core x 2.5 sq.mm with solid/ stranded copper conductor, XLPE/PVC insulated with one layer of galvanized round steel wire / strip armoured and PVC outer sheath and cable shall be conforming to IS 1554(Part-I)/ IS: 7098 (Part I) - 1988 (amended up to date) and bearing ISI mark.

30

-

1100

... More
Laying of 4 core x 16 sq.mm, XLPE-A-PVC cable, 1100 volts grade, heavy duty power cable under item at Sr.No.2.04 above in the built-in-trench from the battery charger to battery bank including supplying and carrying out the work of cable termination and connection of two ends of cable of size 4 core x 16 sq.mm at respective ends by using suitable single compression type cable termination brass glands and crimping type copper lugs as required.

1

-

6500

... More
Laying of 4 core x 16 sq.mm, XLPE-A-PVC cable, 1100 volts grade, heavy duty power cable under item at Sr.No.2.04 above in the built-in-trench from the existing SFU, 32/63 amps 415 volts to battery charger including supplying and carrying out the work of cable termination and connection of two ends of cable of size 4 core x 16 sq.mm at respective ends by using suitable single compression type cable termination brass glands and crimping type copper lugs as required.

1

-

6500

... More
Laying of 2core x 2.5 sq.mm, XLPE-A-PVC cable,650/1100 volts grade, heavy duty control cable under item at Sr.No.2.05 above in the built-in-trench from battery charger to new/old M.V Panel for providing control supply to M.V. Panels in two circuits by laying the cable in parallel, including supplying and carrying out the work of cable termination and connection of four ends of cable respective ends by using suitable single compression type cable termination brass glands and crimping type copper lugs as required.

1

-

8000

... More
Preparing the surface of the existing M.V. Panel by cleaning the sheet steel enclosure using emery/sand paper and cotton cloth and giving one coat of red oxide and two coats of grey paint by brush or spray painting to instruction.

1

-

6500

... More
Preparing the sub-station No.12’s existing earthing stations (2 Nos. for neutral and 2 Nos. for body earthing) by exposing and pouring water and testing the resistance of earthing by using valid earth resistance tester and recording the test results and submitting the test reports to instruction as required.

1

-

13500

... More
Supply, delivery and providing Rubber Insulating Earth Mat of size 2m x 1m, 2.5mm thick (approx.), Class- ‘B’, 11 KV grade, conforming to IS 15652/2006 (amended up to date) for covering the floor of sub-station-12 in front of M.V. & HT Panels to instruction as required.

6

-

2750



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.