Mumbai Port Trust Tender
Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.
Mumbai Port Trust - MBPT Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date26 Sep 2023
Closing Date26 Oct 2023
Tender Amount₹ 91,64,800
Costs
EMD
₹ 1,83,296Document Cost
₹ 5,250Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2023_MBPT_773565_1Bid Award Id
ViewTender No
MEED.22/2023Tender Authority
Mumbai Port Trust ViewPurchaser Address
-Website
http://http://www.mumbaiport.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Light point, to be terminated in angle/ pendent holder for LED Lamp 6 Amps, 230 Volts (for living room, Entrance of the flat, Bedroom, Passage, bathroom, & balconies) as per instructions.
340
-
-
Ceiling fan point to be terminated in a 2/3 plate ceiling rose 6 Amps, 230 Volts for ceiling fan (for living room, bed rooms & kitchen) as per instructions.
120
-
-
Wall socket outlet point on Control board, 3 pins, 6/10 Amps, 230 V (for living room, bed room (3 nos.), kitchen, bathroom(3nos.) & passage) as per the instructions.
280
-
-
Two Wall socket outlet point of 3 pins, 6 Amps, 230 V on Separate board. (for living room, Bed rooms & kitchen) as per instructions.
400
-
-
Electric / Electronic Ding dong call bell point to be terminated in a 2/3 plate ceiling rose, 6 Amps, 230 Volts to be operated by 6 Amps, 230 Volts S. P. Bell Push located at the adjacent wall of the Hall & Kitchen of the flat through S. P. switch to the instructions.
20
-
-
Electric Buzzer point to be terminated in a ceiling rose or as required 6 Amps, 230 Volts located in servant room and to be operated by 6 Amps, 230 volts Bell push to be located at five different locations (Hall, Bedroom no. (1, 2 & 3) and Kitchen) to the instructions. (including wiring of bell push switches).
100
-
-
Exhaust fan point to be terminated in a ceiling rose 6 Amps, 230 Volts for kitchen, bathroom no. 1, 2 & 3 for officer quarters as per instructions.
80
-
-
b) (POWER POINTS) By PVC casing and capping wiring system using rigid PVC casing and capping & FR PVC insulated single core copper conductor wires of size 3 x 2.5 Sq. mm. (Phase, Neutral, Earth), 660 / 1100 Volts grade for power socket points in officer’s quarters as per instructions.
-
-
-
For Individual Flat
-
-
-
Single pole MCB Protected Power socket outlet point, 20 Amps, 230 Volts, 3 Pins heavy duty complete with 20 Amps, 230 Volts modular type socket on separate board using heavy duty surface plastic box with plate & base frame etc. for Kitchen, Bed rooms, Living room, Passage and Geyser as per the instructions.(Similar to Havells DBOXX). (Independent circuit is to be tapped from MCB DB units).
220
-
-
c) For Servant's Quarters and Main Switch Rooms
Wiring in PVC casing & capping system using rigid PVC casing & capping and 2 x 1.5 sq. mm. 660 / 1100 V grade FR-PVC insulated copper conductor single core wires with Piano type switches, sockets, heavy duty PVC switch board etc. to be terminated in ceiling rose / batten/ angle holder etc. (For main circuit wiring and socket point wiring 3 C x 2.5 sq.mm. [phase, neutral, earth] FR - PVC insulated copper conductor single core wires shall be used). The circuit to be tapped from MCB DB unit at individual Flat to the instructions.
-
-
-
Light point, to be terminated in a batten/ angle holder 6 Amp, 230 Volts for LED tube light fitting as per the instructions. (for servant quarters).
20
-
-
Ceiling fan point to be terminated in a ceiling rose 6 Amps, 230 Volts for ceiling fan as per instructions. (for Servant Quarters).
20
-
-
Light point, to be terminated in angle/ pendent holder for LED Lamp 6 Amps, 230 Volts (for bathroom) as per instructions.
20
-
-
Wall socket outlet point on Control board, 3 pins, 6 Amps, 230 V piano type switch as per instructions. (for Servant Quarters).
40
-
-
For METER ROOM, PUMP ROOM & LIFT ROOM
-
-
-
Light point, to be terminated in a batten/ angle/ pendent holder 6 Amps, 230 Volts for LED Tube light as per instructions. (for Meter room (East & West), lift room & Pump Room).
10
-
-
Ceiling light point to be terminated in ceiling rose, 6 Amps, 230 V for Bulkhead Light at Lift Room Entrance and pump room. The circuit for lift room entrance point to be tapped from Lift Room and the light to be operated by single pole switch fixed on entrance of the Lift Room to the instruction.
2
-
-
Wall socket outlet point on Control board, 3 pins, 6 Amps, 230 V piano type switch as per instructions. (for Meter room, lift room & Pump Room).
8
-
-
Exhaust fan point to be terminated in a ceiling rose 6 Amps, 230 Volts for lift room as per instructions.
2
-
-
d) For STAIRCASE, PASSAGE, AVIATION LIGHT, BULKHEAD AND ENTRANCE LOBBY.
Partly by PVC-A-PVC/ XLPE armoured Copper cable of size 2 C x 2.5 sq. mm. 650/1100 Volts grade, along with 1 No. 14 SWG bare copper earth wire for main circuits, (Group Control) with necessary G. I. spacers/ saddles/ clamps fixed on wall/ cable with screws in an approved manner FR-PVC insulated copper conductor single core partly by PVC conduit wiring system using rigid PVC conduit FR-PVC insulated single core copper cable of size 2 x 1.5 sq. mm. 650/1100 V grade for points wiring. The individual light point to be connected through 2/3 plate 6A, 230V ceiling rose through 1.6 mm (approx.) thick Sheet Steel water tight junction box of size 150mm x 100mm x 50mm (approx.) with inbuilt brass terminals/ connector & 4 Nos. knock outs for incoming/outgoing cable/ wires to be fixed on each floor and where ever necessary to the instructions. (The circuit to be tapped from MCBDB unit through timer and contactor switch box which is provided in the Switch/Meter room).
-
-
-
Ceiling light point to be terminated in an angle/ batten holder, 6 Amps, 230 V for LED Tube light fitting for Staircase lighting having group control to the instructions.
23
-
-
Ceiling light point to be terminated in an angle/ batten holder, 6 Amps, 230 V for LED Tube light fitting for Entrance, passage of Building having group control to the instructions. The Passage Light point circuit at each Floor to be run through 6 Amps DP MCBDB to the instruction.
39
-
-
Ceiling light point to be terminated in an angle/ batten holder, 6 Amps, 230 V for Bulkhead Light fitting for at Terrace entrance & lift room entrance. The supply to be tapped from Staircase lighting circuit to the instructions.
4
-
-
Light point to be terminated in DMC type cable looping box (all weather& Water proof with IP 65 & above) with in-built brass terminals/ connectors for the Aviation Lights to be fixed at top of the Terrace area of the building. The supply to be tapped from Staircase lighting circuit to the instructions.
1
-
-
Supply & Delivery at site 2 pole MCBDB unit (Phase & N), ‘C’ series, 6 Amps, 230 Volts suitable for A. C. supply operation, housed in sheet steel enclosure (1.5mm thick) with earth terminal.
11
-
-
e) FOR OUTSIDE LIGHTING ARRANGEMENT. (Stilt/Car parking area & Outside wall lights of the building).
Cabling/ wiring by using PVC-A-PVC/ XLPE armoured copper cable, 1100 Volts grade of size 2c x 2.5 sq. mm. to be terminated in clamp type two way 32A, 230V housed in 1.6mm (Approx.) water tight DMC junction box (all weather& Water proof cable looping box with IP 65 & above) of size 150mm x 100mm x 50mm with in-built brass terminals/ connectors & necessary knockouts having group control & partly in PVC conduit system by 2C X 1.5 sq.mm. FR PVC single core copper cable. The circuit to be tapped from MCBDB unit through timer and contactor switch box along with 1 No. 14 SWG bare copper earth wire to be used as earthing with necessary G.I./ S.S. spacers/ saddles/ clamps fixed on wall/ cable/ conduit with screws in an approved manner to the instructions.
-
-
-
Outside light point to be terminated in a DMC type cable looping box (all weather& Water proof with IP 65 & above) with in-built brass terminals/ connectors for outside LED light fitting to be fixed on Periphery/ Outside wall.
12
-
-
Light point for LED tube light fitting to be terminated in a ceiling rose for Stilt/Car Parking area of the building having group control through MCBDB units. Light point to be tapped from 2 nos. DMC cable looping box to the instructions. (The item rate includes the cost of supply & laying/ fixing of cable and interconnecting wiring).
18
-
-
f) Garden poles lighting.(East & West sites Gardens)
-
-
-
Supply, Delivery, Installation and Commissioning of 5 mtrs. Decorative type Cast Aluminum Garden pole with decorative light housing at top along with LED light fittings (20Watts) having in-built looping box / compartment at base with brass terminals and 1 no. SPMCB unit etc. suitable of entry and termination of 2C x 2.5 sqmm of cable and along with required C.C. foundation, Nuts & bolts, appropriate size of earth pipe(1Mtr.) buried near the pole and to be tapped with G.I. earth wire of size 12 SWG etc. as per specifications and to the instructions.
12
-
-
Supply, Delivery of PVC-A-PVC/ XLPE armoured cable of size 2C x 2.5 sq. mm., 1100 volts grade, with copper conductor.
130
-
-
Laying of L.T. PVC-A-PVC/ XLPE cable, 1100 v grade of size as mentioned above, in the trench of 300 mm (approx..) depth from the ground level by excavating suitable trench in any type of soil/asphalt/ concrete including cleaning the cable trenches, drawing the cable, etc., dressing the cable, back filling the cable trenches after protection to the cable by providing soft screened earth/ sand up to a height of 50 mm. below the cable and 50 mm. above the cable and red brick all along the run of the cable and / or through the G.I. pipes (for concrete portion) and removing all surplus excavated earth from site to the satisfaction of MbPA Site Engineer as required and to the instructions. Charges for supply of required length of GI pipe shall be included in this item. The work also includes termination of cable to both ends i.e. pole end & another end to the DP MCBDB installed at Meter room by providing brass glands of appropriate size, lugs, etc. to the instruction.
130
-
-
Part B - Fittings
-
-
-
Supply & Delivery at site LED Tube light fitting 1200 mm. (approx.) long, ceiling / wall mounting with 1 X 18/20 W LED tube, pre- wired, connector, including mounting arrangement etc. above as required.
350
-
-
Installation, Testing & Commissioning of LED Tube light fitting at sr. no. 2.01 above including adopter, mounting arrangement etc. above as required for officer’s, Servant quarters, Staircase, Pump Room, Switch Room Parking area & lift room to the instructions.
350
-
-
Supply & Delivery at site LED lamp 9 watt 230 V and shall be connected to the light point above to the instructions. (for W.C./ bathrooms, Passage and Balconies of officer’s & servant quarters)
340
-
-
Installation Testing & Commissioning of LED lamp 9 watt, 230 V, and shall be connected to the light point to the instructions. (for W.C./ bathrooms, Passage and Balconies of officer’s & servant quarters).
340
-
-
Supply & delivery of 220-240 AC single phase 50Hz, power saver, energy efficient, Brush Less Direct Current(BLDC) motor, low power consumption, 1400 mm sweep Ceiling fans along with remote and accessories such as 15 inch (approx..) standard down rod or suitable length as required, canopies, inter-connecting wiring using 2/3 Core X 0.75/ 1 sq. mm. PVC/ PVC flexible copper conductor wire, etc. and shall be connected to the light point to the instructions. (for living room, bed rooms of officer quarters).
100
-
-
Supply & delivery of 220-240 AC single phase 50Hz, power saver, energy efficient, Brush Less Direct Current(BLDC) motor, low power consumption, 1200 mm sweep Ceiling fans along with remote / regulator and accessories such as 15 inch (approx..) standard down rod or suitable length as required, canopies, inter-connecting wiring using 2/3 Core X 0.75/ 1 sq. mm. PVC/ PVC flexible copper conductor wire, etc. and shall be connected to the light point to the instructions. (for Kitchen and Servant Quarter of officer quarters).
20
-
-
Installation, Testing & Commissioning of Ceiling fan and shall be connected to the light point to the instructions. (for living room, bed rooms & servant quarters).
120
-
-
Supply & Delivery at site Exhaust fan, Domestic type,300 mm (12") dia. 1300 RPM (approx..) suitable for 230 V, 50 Hz, A. C. supply complete with sturdy Metal body and blades, metal louvers/ screen, as required and interconnecting wiring/ cord to the instructions. (for Kitchen of officer quarters).
20
-
-
Installation Testing & Commissioning of Exhaust fan, Domestic type,300 mm (12") dia. suitable for 230 V, 50 Hz, A. C. supply at sr. no. 2.08 as required and interconnecting wiring/ cord to the instructions. (for Kitchen of officer quarters).
20
-
-
Supply & Delivery at site Exhaust fan, Industrial type,300 mm (12") dia. 1300 RPM (approx..) suitable for 230 V, 50 Hz, A. C. supply complete with sturdy, heavy duty Metal body and blades, metal louvers/ screen, as required and interconnecting wiring/ cord to the instructions. (Similar to "Crompton" make) (for Lift Machine Room).
2
-
-
Installation Testing & Commissioning of Exhaust fan, Industrial type,300 mm (12") dia. 1300 RPM (approx..) suitable for 230 V, 50 Hz, A. C. supply above as required and interconnecting wiring/ cord to the instructions (for Lift Machine Room).
2
-
-
Supply & Delivery at site Exhaust fan, Domestic type, 200 mm (8") dia. 1300 RPM (approx.) suitable for 230 V, 50 Hz, A. C. supply complete with sturdy light weight, rust proof Plastic body and blades, louvers/ screen, as required and interconnecting wiring/ cord to the instructions. (Similar to "Crompton" make)
60
-
-
Installation Testing & Commissioning of Exhaust fan, Domestic type, 200 mm (8") dia. 1300 RPM (approx.) complete with sturdy light weight, rust proof Plastic body and blades, louvers/ screen, as required and interconnecting wiring/ cord to the instructions. (for Bathroom & W. C. of officer quarters)
60
-
-
Supply & Delivery at site Electronic Ding Dong bell suitable for operation on 230 Volts, 50 Hz. A. C. supply by using 2 core, PVC/PVC copper conductor, flexible cord of size 0.75/1 sq. mm or its equivalent to be fixed as per instructions. (similar to Anchor Penta model)
20
-
-
Installation Testing & Commissioning Electronic Ding Dong bell to be fixed as per instructions. (for Officers’ quarters)
20
-
-
Supply & Delivery at site Electric Buzzer (Servant’s room) suitable for operation on 230 Volts, 50 Hz A. C. along with four nos. bell push (Hall, Bed 1 & 2 and kitchen) by using 2 core, PVC/PVC copper conductor, flexible cord of size 0.75/1 sq. mm. or its equivalent to be fixed as per instructions. (For servant quarters).
20
-
-
Installation Testing & Commissioning Electric Buzzer (Servant’s room) suitable for operation on 230 Volts, 50 Hz A. C. along with four nos. bell push (Hall, Bed 1, 2 & 3 and kitchen) by using 2 core, PVC/PVC copper conductor, flexible cord of size 0.75/1 sq. mm. or its equivalent to be fixed as per instructions. (For servant quarters).
20
-
-
Supply & Delivery at site instant type Vertical wall mounting Water Geyser, 3000 Watts (approx.) with 3 Litres capacity, thermostatically controlled, vertical mounting, stainless steel inner container, ABS outer body, PUF insulation, tubular type copper heating element, pressure capacity more than 0.65 MPa, suitable for working on single phase, 230V, 50 Hz A.C. supply complete with flush mounted neon indicating lamp & necessary safety devices (Similar to Racold/Hawells) (one No. for each at Bathrooms of officer's quarter). The item rate also includes the cost of providing 3 pin top of rating 25Amps with ON indication.
60
-
-
Installation Testing & Commissioning of instant type Vertical Water Geyser above The same shall be connected to the point to be fixed as per the instructions along with plumbing work in the existing Hot & Cold pipe installations. (for Bathrooms of officer's quarter).
60
-
-
Supply & Delivery at site LED street light fitting (SMD / COB) in die cast aluminum housing with heat sink extruded aluminum, 60 watts, having IP protection IP 65 or above, confirming to LM 79 & LM 80 standard with surge protection 4 KV minimum suitable to operate on 230 V, 50 HZ A. C. supply
12
-
-
Installation Testing & Commissioning LED type street light fitting. Street light fittings are to be installed on G.I bracket to be installed on Periphery/ outside wall of the building with necessary fixing accessories as per specification and to the instructions.
12
-
-
Providing Bracket for street light fitting made out of class 'C' G.I. pipe of suitable dia. having a length of 1500 mm. (approx.) as per the specifications/ drawings along with suitable fixing arrangement made out of 40 X 6 mm G.I. Patti, clamping, earthing complete with nut bolts etc. and to the instructions.
12
-
-
Supply & Delivery at site Twin dome Aviation light fitting, outdoor type with gasket, PDC LM6 alloy aluminum body, heat resistant polycarbonate covers and powder coated wire guard complete with 230 volts, 2 x10W LED Lamp.
1
-
-
Installation Testing & Commissioning Aviation Light Fittings on the highest point of the building / top of the lift machine room with necessary fixing accessories as per specification and to the instructions.
1
-
-
Supply & Delivery at site Bulkhead light fitting, outdoor type with gasket, cast aluminum body, heat resistant glass covers and powder coated wire guard complete with 230 volts, 9W LED Lamp.
5
-
-
Installation Testing & Commissioning of Bulkhead light fitting, 9W LED Lamp at sr. no. above (for entrance of the Lift Machine Room, Terrace Entrance & Pump Rooms to the instruction.
5
-
-
Part C Main Service - cum - meter boards, Sub-mains cables, Switch gears, miscellaneous works, etc.
-
-
-
Supply & Delivery at site of PVC-A-PVC/XLPE cable of size 4C x 10 sq. mm., 1100 Volts grade with copper conductors.
715
-
-
Installation/laying of cable at sr. no. 3.01 above to be run/ laid/ fixed on the FRP Cable Tray/wall/ beam /ceiling by using G.I. clamps, saddles and spacers etc. to serve as Sub-Mains to the flat. Cable to be laid from the Bus-Bar Chamber to Meter board at Meter Room and to the TPN MCBDBs installed in each flat. Cable from Meter room to each flat shall be run/ laid through the Cable tray (having necessary opening on each floor). 1 No. bare copper conductor earth wire of size 14 SWG for each flat to be tapped from the nearest rising earth main available on each floor and to be laid along with sub-mains cable to the instructions. The Existing cable box unit shall be dismantled to remove old cables. (This includes charges for supply of copper earth wire, glands & lugs for both end termination)
715
-
-
Supply, Delivery & installation at site of 450mm wide Perforated FRP Cable tray with tray cover. Installation of cable tray by providing 35 x 35 x 6 mm M.S angle frame at a space of 1000mm along with FRP cover.
15
-
-
Supply, Delivery & installation at site of 300mm wide Perforated FRP Cable tray with tray cover. Installation of cable tray by providing 35 x 35 x 6 mm M.S angle frame at a space of 1000mm along with FRP cover.
65
-
-
Supply, Delivery & installation at site of 50mm wide Perforated FRP Cable tray with tray cover. Installation of cable tray by providing ‘Z’ shaped M.S angle frame at a space of 300mm along with FRP cover.
80
-
-
Supply & Delivery at site of 4 pole MCBDB (R, Y, B & N) unit, ‘C’ series, 63 Amps, 415 Volts suitable for A. C. supply operation, housed in sheet steel enclosure (1.5mm thick) with earth terminal.
27
-
-
Installation, Testing & Commissioning of 4 pole MCBDB unit, at sr. no. 3.04 to be fixed on Meter Board along with copper wire earthing to the instructions for outgoing from Energy Meter to Flats, Temporary supply and Lift MCBDB.
27
-
-
Supply & Delivery at site of Single pole MCBDB unit, ‘C’ series, 63 Amps, 230 Volts suitable for A. C. supply operation, housed in sheet steel enclosure (1.5mm thick) with earth terminal.
84
-
-
Installation, Testing & Commissioning single pole MCBDB unit at sr. no. 3.06, with copper wire earthing. MCBDB to be installed between Bus bar chamber & Energy Meter as incomer (4nos in each feeder) for Flats and Temporary Supply.
84
-
-
Supply & Delivery at site 2 pole MCBDB unit (Phase & N), ‘C’ series, 20 Amps, 230 Volts suitable for A. C. supply operation, housed in sheet steel enclosure (1.5mm thick) with earth terminal.
25
-
-
Installation, Testing & Commissioning 2 pole MCBDB unit, at sr. no. 3.08 to be fixed on Meter Board as main incomer(before Energy Meter) for Staircase & Passage, Outside, parking area Lights, lift Room. For Servant Quarters 2 Pole MCBDB unit shall be installed in individual servant quarter.
25
-
-
Supply & Delivery at site 2 pole MCBDB unit (Phase & N), ‘C’ series, 10 Amps, 230 Volts suitable for A. C. supply operation, housed in sheet steel enclosure (1.5mm thick) with earth terminal.
3
-
-
Installation, Testing & Commissioning of 2 pole MCBDB unit, at sr. no. 3.10 to be fixed on Meter Board for outgoing for Garden Poles of East and West wing, Meter Rooms, Passage & Staircase light of each floor and at Pump room to be fixed on Meter Board to the instruction.
3
-
-
Supply & Delivery at site of Timer Switch box. Timer Switch box fabricated out of 16 SWG (1.6 mm. approx.), size 350 mm x 300 mm x 150 mm thick Sheet Steel in folded/Welded construction with suitable fixing and locking arrangement including, 1 No. 4 pole 415V, with 230V actuating coil, 20A Power contactor, 1 No. 230V quartz control mechanism for Automatic ON/OFF operation with daily dial feature, Timer switch, 1 No. Auto/ Manual switch, 1 No. MCB 20 Amps and 1 No. 4 way Bakelite terminal block. Complete with interconnecting wiring between the items using PVC insulated Copper conductor wire including earthing and to the instructions.
2
-
-
Installation, testing & commissioning of Timer Switch box
(The Timer switch box is to be fixed on Meter board between Energy Meter and single phase Changeover switch at West wing sw. room & between Energy Meter and DP MCBDB at east wing with necessary fixtures to be connected for Staircase, Passage, Stilt area & Outside lights & Garden pole supply to the instruction.
2
-
-
Supply & Delivery at site of TPN, 4Way double door Sheet Steel Main distribution boards (MCB DBs), suitable for mounting TPN, DP MCB units, with slotted lid type complete with appropriate size of tinned copper bus-bar, tinned copper/ brass neutral link, interconnecting wiring using copper wires/ bars, DIN channel with necessary mounting arrangement with knockouts for cables/ wires including earthing lugs, studs, and comprising of the following items:
TPN MCBDB unit consisting the following items: -
i) 4Pole MCB unit 63 Amps, - 1 No.
ii) 4pole RCCB unit, 63 Amps, with 30 mA sensitivity- 1 No.
iii) DP MCB unit 40 Amps. – 05Nos.
iv) DP MCB unit 20Amps - 01No. Similar to Legrand make
20
-
-
Installation, testing & commissioning of TPN double door Sheet Steel Main distribution board (MCB DB) at sr. no. 3.14 above as per instruction. These MCBDBS are to be fixed inside Flats, to the instructions.
20
-
-
Supply & Delivery at site of Sheet Steel distribution boards (MCB DBs)(6 ways)suitable for mounting SP, DP, MCB units, single door with acrylic cover, slotted lid type complete with appropriate size of tinned copper bus-bar, tinned copper/ brass neutral link, interconnecting wiring using copper wires/ bars, DIN channel with necessary mounting arrangement with knockouts for cables/ wires including earthing lugs, studs, and comprising of the following items:
MCBDB unit (6 ways) consisting the following items: -
i) DP MCB unit 40 Amps. –1 No.ii) SP MCB unit 20 Amps. – 4Nos.Similar to HPL make.
100
-
-
Installation, testing & commissioning of Sheet Steel distribution boards (MCB DBs) at sr. no. 3.16 above to the instruction.
The DBs to be installed at Living Room, Bedroom 1,2,3 & Kitchen of each flat and as per site instructions.
100
-
-
Main circuit Wiring by 3R x 4 sq.mm. 660/1100 V grade FR –PVC wire between 4Way TPN DB & 6Way single phase MCBDBs installed at Living room, Bedroom 1,2,3 & kitchen (total 5 locations) & servant quarter in each Flat using rigid PVC casing & capping to the instructions.
20
-
-
Supply & Delivery of Sheet Steel TPN Switch Fuse Unit, 630Amps, 415V along with 3 Nos. 630 Amps HRC fuses with suitable size Sheet Steel Spreader Box of having 250mm or more height suitable for terminating one end of PVC/XLPE armoured aluminum cables of size 4 x 630 sq.mm, 1100 volts grade and other end to Bus-bar Chamber with copper extension busbars of appropriate size with earthing terminals.
6
-
-
Installation, Testing & Commissioning of Sheet Steel 630A TPN Switch Fuse unit and Sheet Steel Spreader Box (at sr. no. 3.19 above) along with copper extension busbars. The work also includes connecting extension busbar to bus bar chamber with brass nut, bolts and bimetallic washers etc 02 nos. SFU along with spreader box shall be installed at Switch room of both wings for incomers & 02 units shall be installed between Busbar chamber & outgoing cables at B.E.S.T switch chamber to the instruction. The work also includes termination of existing cable by providing brass glands of appropriate size, lugs, etc. In BEST switch chamber the new 02 Nos. 630 Amps SFU unit shall be installed with modification if required in Bus Bar chamber after removal of existing 400 Amps SFU unit.
6
-
-
Supply & Delivery of Sheet Steel TPN Switch Fuse Unit, 250Amps, 415V along with 3 Nos. 250 Amps HRC fuses with suitable size Sheet Steel Spreader Box of having 250mm or more height suitable for terminating one end of PVC/XLPE armoured aluminum cables of size 4 x 185 sq.mm, 1100 volts grade and other end to Bus-bar Chamber (at sr. no. 3.20 above) with copper extension busbars of appropriate size with earthing terminals.
1
-
-
Installation, Testing & Commissioning of Sheet Steel 250A TPN Switch Fuse unit and Sheet Steel Spreader Box (at sr. no. 3.19 above) along with copper extension busbars. The work includes connecting extension busbar to bus bar chamber with brass nut, bolts and bimetallic washers. (O/G to Atithi/Retiring Room west wing) to the instruction. The work also includes termination of existing cable by providing brass glands of appropriate size, lugs, etc.
1
-
-
Supply & Delivery of Sheet Steel TPN Switch Fuse Unit, 125Amps, 415V along with 3 Nos. 125Amps HRC fuses with suitable size Sheet Steel Spreader Box of having 250mm or more height suitable for terminating one end of PVC/XLPE armoured aluminum cables of size 4 x120 sq.mm, 1100 volts grade and other end to Bus-bar Chamber (at sr. no. 3.22 above) with copper extension busbars of appropriate size with earthing terminals.
1
-
-
Installation, Testing & Commissioning of Sheet Steel 125A TPN Switch Fuse unit and Sheet Steel Spreader Box (at sr. no. 3.23 above) along with copper extension bus bars. The work also includes connecting extension bus bar to bus bar chamber with brass nut, bolts and bimetallic washers. (for O/G to Dougle House East wing) to the instruction. The work also includes termination of existing cable by providing brass glands of appropriate size, lugs, etc.
1
-
-
Supply & Delivery of Sheet Steel TPN Switch Fuse Unit, 63Amps, 415V along with 3 Nos. 63Amps HRC fuses with suitable size Sheet Steel Spreader Box suitable for terminating one end of PVC/XLPE armoured aluminum cables of size 4C x 25 sq.mm, 1100 volts grade and other end to 3 phase terminal Box with copper extension cable of appropriate size with earthing terminals.
1
-
-
Installation, Testing & Commissioning of Sheet Steel 63A TPN Switch Fuse unit and Sheet Steel Spreader Box (at sr. no.3.25 above) along with. The work also includes the termination of 4c x 25 sq.mm AL. armoured cable and other end to the 3 Phase Terminal Box brass nut, bolts and bimetallic washers. (for alternative supply for fire lift at West wing) to the instruction. The work also includes termination of existing cable by providing brass glands of appropriate size, lugs, etc. (for Incomer supply Lift Emergency, from BEST).
1
-
-
Supply & Delivery of 630 Amps, 415 Volts appropriate size Sheet Steel Bus-Bar Chamber (not less than 1500 x 600 x 250 mm). made out of 12 SWG Sheet Steel having suitable size tinned copper bus-bars for 3 phases and neutral, fitted with suitable epoxy/ DMC insulators, heat shrinkable sleeves with LED indicators on Panel (RYB), with necessary openings/Knockouts for outgoing to MCBDBS & SFUs with earthing terminals at both side. Bus-bar chamber shall be painted with one coat of epoxy primer and two coats of epoxy paint. The nut-bolts used must be of Brass with bimetallic washers.
2
-
-
Installation, Testing & Commissioning of Sheet Steel Bus-Bar Chamber at sr.no.3.27 above. The work includes, fixing of Bus-bar chamber on wooden Switchboard & connection of earth terminals by 14SWG bare copper wire to earth strip with necessary G.I. nuts, bolts, bimetallic washers & accessories.
2
-
-
Supply, Delivery of 3 Phase Electronic Energy Meter in Polycarbonate body with LCD Display class 1.0 accuracy suitable for Three phase(415V), A.C. Supply of capacity 10-60 Amps with ISI mark (Similar to “HPL” make)
24
-
-
Installation, Testing & Commissioning of Energy Meter at Sr. no. 3.29 to be installed on Meter Board inside Meter Room. (20 nos. for Flats & 1 no. for temporary Supply 03 Nos for three Lifts)
24
-
-
Supply & Delivery of Single Phase Electronic Energy Meter in Polycarbonate body with LCD Display class 1.0 accuracy suitable for 1 Phase, 230V, A.C. Supply of capacity 10-20 Amps with ISI mark (Similar to “HPL” make)
2
-
-
Installation, Testing & Commissioning of Single Phase Electronic Energy Meter on meter board at Sr. no.3.31 for Staircase & Outside Light as shown in drawing
2
-
-
Supply and delivery at site of PVC-A-PVC/XLPE Cable heavy duty of size 3½C x 400 sq.mm. with Aluminum conductor 1100 Volts grade size of L.T cable with stranded H2/H4 grade aluminum conductor XLPE insulated, colour coded, laid up, with fillers and / or binder tape, extruded PVC inner sheath, one layer of galvanized round steel wire / strip armoured and PVC outer sheath. Both inner and outer sheath shall be conforming to IS 1554 / 7098 (Part-I) – 1988 (amended up to date) and bearing ISI mark in standard drum length complete with test certificates for type test, routine test and acceptance test.
350
-
-
Excavation of cable trench of 500mm width & 900 mm (approx.) depth from the ground level in soft soil.
10
-
-
Excavation of cable trench of 500mm width & 900 mm (approx.) depth from the ground level in asphalt / hard soil / rocky surface.
50
-
-
Excavation of cable trench of 500mm width & 900 mm (approx.) depth from the ground level in concrete.
30
-
-
Laying of above said cable by cleaning the cable trenches, drawing the cable, dressing the cable, after protection to the cable by providing soft screened earth / sand up to a height of 100 mm below the cable and 150 mm above the cable and placing whole red bricks all along the run of the cable. The brick shall be laid across the run of the cable. Or laying the cable through the R.C.C pipes to be provided & laid.
300
-
-
Laying of above said cable other than in excavated trench (i.e. on wall by providing suitable size G.I "C" type bracket with U type clamp / or laying in existing trench as per the site instruction.
50
-
-
Reinstatement of cable trench by backfilling cable trench and providing concrete of M25 grade up to 300mm thick.
30
-
-
Supply & delivery at site of maintenance free Chemical Copper Earthing set with earth Electrode of Dia. 40mm, length of 3Mtr. Having size of inner conductor 25x6, for earthing with Chemical Powder (Marconite /Bentonite) & copper fixing accessories.
6
-
-
Providing Earthing arrangement by using Chemical Earth Electrode at sr. no. 3.35 above for earthing with Chemical Powder (Marconite/Bentonite) (for Main Service Board in Switch Room and Rising earth main for flats and outside lighting etc.) complete with Chemical Powder (Marconite /Bentonite) and watering arrangement by making 100mm Dia x 3Mtr. long bore. Providing 500 x 500 x 200 mm pit (approx.), cement concrete (1:2:4) chamber/pit with 125 mm. (approx.) wall thickness having R.C.C. cover of 100 mm (approx.) thick. The earthing Rod shall be buried vertically at a depth of 3 meters from ground level. The resistance of the earthing station shall be tested with calibrated Earth Resistance Tester and results to be submit for records to the instructions. The nut-bolts used must be of Brass/G.I. (4 Nos. for main service boards, 02 Nos for Lightning Arrestor (East and West Wings) and Residential units through rising earth main to the instruction. The work includes providing the appropriate size of G.I. Earth strip from Earth pit to the main earth connection in the Meter room with laying in the concrete /ground and termination to the instruction. The work also includes providing interconnection between existing earth pit strip and new earthing pit strip of main service board.
6
-
-
Providing Rising earth main to the building by using G. I. Strip of size 32 x 6 mm (approx.) to be tapped from the earthing terminals at sr. no. 3.36 above and to serve as earth risers for the flats of both the wings through meter boards. The rising main earthing strips shall be fixed on the wall/beam/ceiling using G. I. spacers/ saddles/ clamps/ lugs/ nut-bolts etc. to the instructions.
170
-
-
Saddling of the existing 2 nos. earthing strip laid outside of the building for Lightning Arrestors in both the wings by providing G.I spacers, clamps at space of 400mm with Nut Bolts for strip joints etc. and removal of existing wooden saddles, spacers. The work also includes installation of existing L.A at terrace of building by providing suitable clamps & fixtures.
1
-
-
Supply, Delivery, Installation, Testing and Commissioning of 3phase, 4 pole, 63 Amps powder coated On - load Changeover switch. The work also includes termination of 2 nos. incoming & 1 nos. outgoing cables with appropriate size of Glands & lugs to the instruction. Item includes supply cost of necessary glands and lugs.
1
-
-
Supply, Delivery, Installation, Testing and Commissioning of single phase, 2 pole, 20 Amps powder coated On-Load Changeover switch. The work also includes termination of 2 nos. incoming & 1 nos. outgoing cables with appropriate size of Glands & lugs to the instruction. Item includes supply cost of necessary glands and lugs.
1
-
-
Supply, Delivery, Installation, Testing and Commissioning of 3phase, 4 pole, 63 Amps Metal coated Terminal box with Bus Bars. The work also includes termination of 1 nos. incoming & 2 nos. outgoing cables with appropriate size of Glands & lugs to the instruction.
1
-
-
Part- D Miscellaneous
-
-
-
Repairing/Refurbishing the existing Wooden Meter Boards and Meter Room (East and West Wing). The work includes i) Refurbishing, Varnishing, painting to the existing Meter Boards of both the wings
ii) Fixing and terminating, cables of size 4 C X 10 Sq. mm. XLPE/PVC-A-PVC armoured Copper conductor from Bus bar chamber to Meter Board along with providing suitable size lugs and gland at one end.
iii) The work shall includes providing interconnecting wiring, laying in appropriate size flexible conduit terminating between the SPMCBDB, Energy Meters, Switchgears, TPN MCBDBs, DP MCBDB, Terminal Box, Changeover switches with earthing bare copper conductor wire of size 14 swg. (3.2 sq. mm. approx..), lugs, cable glands, studs / bolts of appropriate size etc. and fixing the conduit using G.I./ S.S. saddle/ clamps/ spacers in proper manner as required and to the instructions and as per drawing.
The item includes providing locking arrangement to the meter rooms (East and West wing) with 02 Nos. 50 mm dia Godrej Navtal Lock to the instruction.
2
-
-
Disconnecting & Dismantling the existing electrical installations such as Point wiring, main, sub main cables, MCBDB, switch boards, light fittings, fans, Energy Meters, Cable M.S. box, all switchgears etc.
1
-
-
Providing RJ 11 type, modular series telephone socket with shutter (1 module) in replacement of existing one complete with surface type plastic box, etc. properly fixing the telephone wire by using PVC casing capping Patti of suitable size and neatly dressing the telephone wire in the flat to the instructions.
20
-
-
Providing TV socket, modular series (1 module) and terminating and connecting the co-axial cable in the socket complete with, surface type plastic box, etc. fixing the TV cable by using PVC casing capping Patti of suitable size to the instructions.
20
-
-
Part- E Civil Works
-
-
-
Cement and sand plaster (1:5) 20 mm thick internally up to floor two level to brick work and concrete surfaces including raking out joints of brick work to a depth of 20 mm and roughening concrete surfaces & finishing plaster smooth with cement or neeru as directed etc. complete. (Page No. 37, It.No. 2 a).
100
-
-
Providing and applying 2 coats of velvet paint/ super acrylic emulsion paint of approved brand, quality and shade including thoroughly scrapping, cleaning, applying putty and primer coat and preparing surface to receive paint etc. complete as directed. (Page No. 47, It. No. 42)
200
-
-
Two coats of oil bound distemper of approved brand/ manufacture and shade over a primer coat of approved brand/ manufacture on new surface to give an even shade including thoroughly scraping cleaning, making even and preparing the surface complete as directed. (Page No. 41, It. No. 3)
200
-
-
Part- F Buyback
-
-
-
Buy Back of old and dismantled materials at sr. no. 4.02 above.
1
-
-
Evaluation Notes How It Works ?
Potential Partner