Mumbai Port Trust Tender
Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.
Mumbai Port Trust - MBPT Tender
Eprocure
Opening Date7 Jul 2018
Closing Date26 May 2020
Tender Amount₹ 14,00,820
Costs
EMD
₹ 28,100Document Cost
₹ 5,250Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2020_MBPT_556645_1Bid Award Id
ViewTender No
MEED.03/2020Tender Authority
Mumbai Port Trust ViewPurchaser Address
-Website
http://http://www.mumbaiport.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Fan point to be terminated in ceiling rose 6 Amp, 250 V for ceiling fan in living room , bedroom, Welfare hall / office & Pump room.
(SOR ( E) page no.53 sr. no.842)
67
-
412.98
Wall socket outlet point , 4 pin and earth, 6A, 250 V on separate board for living room , bedroom , Welfare hall / office & pump room by using 3 x 1.5 sq. mm 660 / 1100 V grade FR-PVC insulated copper conductor single core wire.
(SOR ( E) page no.55 sr. no.850)
66
-
787.11
Wall socket outlet point , 4 pin and earth, 6A, 250 V on control board for living room, bedroom, kitchen, meter room , Community Hall & Pump room by using 3 x 1.5 sq. mm 660 / 1100 V grade FR-PVC insulated copper conductor single core wire.
(SOR ( E) page no.53 sr. no.843)
111
-
206.49
Bell point in kitchen to be terminated in a bell and to be operated from bell push provided near entrance door of the flat.
(SOR ( E) page no.53 sr. no.842)
b) Wiring in PVC casing & capping system using rigid PVC casing & capping and PVC insulated stranded copper conductor wire of size 3C x 4 sq. mm, 660 / 1100 V grade
46
-
412.98
Wiring in PVC casing & capping system using rigid PVC casing & capping, 3 X 4 sq mm (Phase, Neutral, Earth) 660 /1100 V grade FR-PVC insulated copper conductor single core wires for one no. wall socket outlet point, 5 pins, 10/20 A, 230 V piano type switch & socket as separate point using heavy duty (3 mm approx. thick) surface plastic / PVC box / board with acrylic / plastic / PVC cover plate, etc. for kitchen, bathroom, Community Hall & Pump room. (Separate circuit for kitchen, bathroom, Community Hall & Pump room respectively from MCBDB).
(SOR ( E) page no.56 sr. no.856)
(c) Partly by using 2C x 4 sq. mm. PVC/ XLPE-A-PVC insulated, PVC sheathed cable, 1100 Volts grade with copper conductor and partly by rigid PVC conduit system, with PVC insulated stranded, single core copper conductor wire of size 2.5 sq.mm, 1100 V grade.
93
-
1124.6
Wiring partly by PVC / XLPE- A-PVC, 1100 V grade cable for ceiling light point to be terminated in a ceiling rose 6 Amps, 250 volt for LED Tubelight fitting for staircase and passage. The supply is to be tapped from the Timer and contactor unit to be fixed on meter board of the building and installing 1 No. 32 Amp, MCBDP in meter room of the building. The wiring is to be carried out in PVC / XLPE-A-PVC insulated, PVC sheathed cable up to the junction box of each floor and in PVC conduit from the junction box up to the ceiling rose. The PVC / XLPE-A-PVC insulated, PVC sheated cable has to be terminated in the bakelite terminal block clamp type 30 Amps, 250 Volts housed in sheet steel junction box of size 150 x 100 x 50mm (approx) & 1.6 mm thick (approx) duly painted to be fixed at each floor and in the DP switch by using suitable cable termination glands. The junction box shall be of size 200 x 100 x 50mm (approx) and 1.6mm thick (approx) duly painted having 4 way terminal block clamp type 30 Amp, 250Volt for tapping the supply for street light fitting.
(SOR ( E) page no.59 sr. no.867)
37
-
1176.78
Wiring by using PVC / XLPE-A-PVC, 1100 V grade cable for outside light point for 60 watt LED COB Type street light fitting to be terminated in a clamp type two way, 32 A, 230 V bakelite terminal block housed in 1.6 mm (approx.) thick sheet steel water tight box of size 150 X 100 X 50 mm / DMC cable looping box for 60 watt LED street light fitting. The circuit to be tapped from ground floor or first floor sheet steel junction box of staircase lighting to the instructions.
9
-
1595.31
II - FITTINGS
-
-
-
LED tube light fitting for living room, bed room, kitchen, staircase, passage,meter room & Pump room, 1200 mm( approx) long, ceiling / wall mounting with 1 X 18 / 20 W LED tube, pre- wired,connector, side holders and interconnecting wiring by using 2 / 3 core X 0.75 sqmm. PVC / PVC flexible copper conductor wire including mounting arrangement with adaptor etc. as required (similar to "Philips" make) for staircase, passage & meter room.(Rate based on the sanctioned Estimate No.MEED.104/2018-19 item no 12).
153
-
406.25
LED lamp 5 watt, 230 V for bathroom. W.C & Passage in Front of Bathroom & W.C (Rate based on the sanctioned Estimate No.MEED.104/2018-19 item no 11)
139
-
84.82
Night lamp LED,0.5 watt, 230 V in Bedroom (Rate based on the sanctioned Estimate No.MEED.104/2018-19 item no 13)
60
-
39.29
Ceiling fan, 1200 mm sweep, decorative type, suitable for single phase, 230 V, 50Hz, A.C. supply operation complete with accessories such as standard down rod, canopies , electronic step type fan regulator (similar to Anchor Roma), inter-connecting wiring using 2 / 3 core X 0.75 sq.mm. PVC / PVC flexible copper conductor wire, etc. for living room, Bedroom & Community Hall (similar to "Crompton" make model "Aura").
(SOR ( E) page no.17 sr. no.375)
67
-
2556.07
Supply, Delivery & installation of LED (COB type) street light fittting in die cast aluminium housing minimum 60 watts, having IP protection IP 66 (minimum), confirming to LM 79 & LM 80 standard with surge protection 4 KV minimum suitable to operate on 230 V, 50 HZ A.C. supply (similar to Merrylight model No.MSL60MW) These street light fittings are to be installed on building No. 1 & 2 , Pump room. (Rate based on the sanctioned Estimate No.MEED.104/2018-19 item no 15)
9
-
5311.72
Supply, Delivery & Installation of bracket for LED street light fitting mentioned at Sr. No. 15 made out of class 'C' 50 mm dia. G.I. pipe having a length of 2000 mm as per the instructions / drawing to be installed on wall / terrace of the building including interconnecting wiring of suitable size between fitting and backlite terminal block in junction box along with suitable fixing arrangement complete with GI clamps and nut bolts etc.
9
-
1793.19
Electric ding dong sound door call bell, 230V, A.C. supply (similar to "Anchor" City-model) .
(SOR ( E) page no.47 sr. no.605 )
46
-
94.22
III - MAINS, SUBMAINS AND SWITCHGEARS.
-
-
-
a) Supply, Delivery and Laying of PVC / XLPE insulated PVC sheathed armoured heavy duty cable of size 2C X 6 sq. mm., 1100 V grade with copper conductor to be run on wall from MCB DP Switch, in the meter board to the MCBDB under item at Sr. No. 22, in one living room-kitchen unit to serve as submains including termination at both the ends by using appropriate size gland and 1 no copper earth wire of size 12 SWG to be tapped from rising main earth of size 25 X 3 mm of G.I.strip. -Rs.133.32/-per meter.
(SOR (E) page No.2,Sr.No.59)
b) For laying of cable at the rate of 19.65 % per meter - Rs.26.19/-per meter SOR (E),page No.13, Sr No.369
1354
-
135.18
a) Supply, Delivery and Laying of PVC / XLPE insulated PVC sheathed armoured heavy duty cable of size 2C X 10 sq. mm., 1100 V grade with copper conductor to be run on wall from MCB DP Switch, in the meter board to the MCBDB under item at Sr. No. 23, in 2 BHK unit to serve as submains including termination at both the ends by using appropriate size gland and 1 no copper earth wire of size 12 SWG to be tapped from rising main earth of size 25 X 3 mm of G.I.strip.- Rs.202/- (SOR (E) page No.2, Sr.60)
b) For laying of cable at the rate of 19.65% per meter. Rs. 39.693/- (SOR (E) page No.13 ,Sr.369)
165
-
204.82
MCB DP 32 Amp, 415 V for each One R K unit, stair case / passage, Pump room & Street Lighting to be installed on meter board in approved manner.
(SOR (E), page no. 63, sr. no. 936)
40
-
306.16
MCB DP of 40A, 415 V Two BHK each unit & Welfare hall to be installed on meter board in approved manner.
(SOR ( E) page no.63 sr. no.936)
9
-
306.16
2 way, 32 A, 240 V bakelite terminal block (interlocking) clamp type with end plate for individual staircase lighting to be installed on the meter board. (Similar to 'cerco' make).
(SOR ( E) page no. 67 sr. no.1051)
54
-
49.27
Single door sheet steel distribution board single pole and neutral in sheet steel enclosure, consumer unit type powder coated, single door with acrylic window, surface / recess mounting fitted with insulated tinned copper bus bar, neutral link, DIN channel, earthing terminal, etc. suitable for housing SP / DP MCB / RCCB 8 way - Rs.827.99/-.
(SOR ( E) page no.60 sr. no.879)
1) DP Isolator SP & N 32 A, 250 V, C series (motor duty) - 1 No. -Rs.361.27/-
((SOR ( E) page no.63 sr. no.936)
2) DP RCCB unit, 20 Amp, 250 V, 300 mA sensitivity, C series(motor duty) - 1 No. -Rs.1949.41/-
(SOR ( E) page no.63 sr. no.953)
3) SPMCB 16 A, 250 V, C series (motor duty)- 2 No. - Rs.426.74/- (SOR ( E) page no.62 sr. no.913)
4) SPMCB 6 A, 250 V, C series (motor duty) - 2 No. - Rs.426.74/-
(SOR ( E) page no.62 sr. no.913)
to be fixed on M.S. bracket of appropriate size & at suitable location in each unit to the instructions
40
-
3383.18
Single door sheet steel distribution board single pole and neutral in sheet steel enclosure, consumer unit type powder coated, single door with acrylic window, surface / recess mounting fitted with insulated tinned copper bus bar, neutral link, DIN channel, earthing terminal, etc. suitable for housing SP / DP MCB / RCCB 12 way - Rs.914.69/-.
(SOR ( E) page no.60 sr. no.875)
1) DP Isolator SP & N 40 A, 250 V, C series (motor duty) - 1 No. -Rs.361.27/-
(SOR ( E) page no.63 sr. no.936)
2)DP RCCB unit, 25 Amp, 250 V, 300 mA sensitivity, C series (motor duty) - 1 No. -Rs.1949.41/-
(SOR ( E) page no.63 sr. no.953)
3) SPMCB 16 A, 250 V, C series (motor duty)- 4 No. - Rs.853.48/- (SOR ( E) page no.62 sr. no.913)
4) SPMCB 6 A, 250 V, C series (motor duty) - 4 No. - Rs.853.48/-
(SOR ( E) page no.62 sr. no.913)
to be fixed on M.S. bracket of appropriate size & at suitable location in each unit to the instructions
9
-
4179.94
Time switch suitable for operation on single phase, 230 V, 50 HZ, A.C. supply, 16 A rating having quartz control mechanism with daily dial feature for automatic switching ON / OFF operation with one air break contactor unit 16 Amps, 3 pole having actuating coil of 230 V and one 5A, 250 V switch to serve as by pass housed in a common sheet steel box made out of 1.6 mm (approx.) thick sheet steel duly painted with insulated cover plate of 3 mm (approx.) thick including interconnecting wiring. This box should have appropriate size knock outs and is to be installed near meter board of the building.
(SOR ( E) page no.66 sr. no.1032
2
-
1996.08
Providing earthing arrangements for each meter board & at Pump room by using one no. Galvanised cast iron earth plate of size 600 X 600 X 12 mm thick (approx.) and two nos. G. I. strips of size 25 X 5 mm thick (approx.) complete with 10 kg. of charcoal and 10 Kg. of salt and watering arrangement using 20 mm dia 'C' class G.I.pipe, funnel with wire mesh, water inlet pipe, 400 x 400 x 400 mm (approx) cement concrete (1:2:4) chamber with 125 mm (approx) wall thickness and RCC cover of 100 mm (approx) thick. The earthing plate shall be buired vertically at a depth of 2.5 meter from ground level. The resistsnce of earthing station shall be tested with calibrated Earth Resistance Tester and results recorded as requred ( For main service boards etc. having up to 300 Amp rating.)
(SOR ( E) page no.12 sr. no.366)
6
-
6389.83
Rising Earth main of size 25 X 3 mm GI strip from each meter Board on Ground floor to top floor of the building by making necessary holes in slab / wall, painted by black colour in approved manner.
(SOR ( E) page no.12 sr. no.356)
80
-
44.51
Installation charges for fixing / running rising earth main (Sr. No.27) on the even surface wall / beam / ceiling by providing appropriate sizes of G.I. saddles and M.S. /G.I. spacers as per MbPT specifications.
(SOR ( E) page no.13 sr. no.369)
80
-
8.75
IV MISCELLANEOUS WORK
-
-
-
Disconnecting and dismantling the existing electrical installations at Building No. 1 & 2 ,such as point wiring, DB, switch boards, light fitting, fan etc. and switchgears etc. from exisitng meters board installation of new switchgears etc. including varnishing the existing meters board, interconnecting wiring between the new meters, cutouts, DP switches, MCB units, etc. as required. The item includes provision of locking arrangement to metres room/cup-board by 50 mm dia Godrej Navtal Lock . (SOR ( E) page no.72 sr. no.869 and Departmental Rate Analysis )
2
-
5593.22
Strengthening the supply System from Meter room of Building No.2 to Pump room.
-
-
-
Supply & delivery at site a PVC / XLPE-A-PVC cable of size 3 1/2 C x 70 sq. mm. Aluminium Conductor, 1100 Volts grade to be laid between Meter room of Building No.2 & Pump room.
(SOR (E) page no. 3, sr. no. 108)
40
-
209.7
Laying of L.T. PVC / XLPE - A - PVC cable, 1100 volts grade mentioned under item at Sr. No.30 in the trench of 900 mm (approx.) depth from the ground level by excavating suitable trench in any type of soil / asphalt / concrete including cleaning the cable trenches, drawing the cable using rollers, jacks, etc., dressing the cable, back filling the cable trenches after protection to the cable by providing soft screened earth/s and upto a height of 100 mm below the cable and 150 mm above the cable and placing whole red bricks all along the run of the cable and / or through the R.C.C.pipes/built-in-trench/duct and removing all surplus excavated earth from site to the satisfaction of MbPT Site Engineer as requied. (SOR ( E) page no.13 sr. no.367)
40
-
499.58
Termination and connection of both the ends of cable mentioned under item No. 30 above by using appropriate size of crimping type aluminium lugs and suitable size of brass cable glands. The job includes disconnecting and removing the tail ends of exising cables & to be burried the same to the instructions.
(SOR ( E) page no.9 sr. no.315)
1
-
498.37
Switch Fuse Unit , rewirable type, cast iron clad / sheet metal clad,triple pole & neutral (C.I.T.P.& N/S.S.T.P.& N.)of 63 A,current rating suitable for 415 V, suitable for A.C.supply.
(SOR ( E) page no.64 sr.no.981)
2
-
3559.42
R.C.C. pipe of 150mm dia NP2 class with necessary R.C.C. jointing coupler ring and laying the same across roads, culvert drain.
(Rate obtained from CE Dept.SOR, Page No.113, Sr No.9)
8
-
465.25
Reinstatement work affected due to electrical work like mains / sub mains cable for induivual units , meter room of building no.1 & 2 , supply cable from Meter room of bldg.no.2 to pump room etc.
-
-
-
a) Reinstatement work on wall ceiling in rooms affected due to rewiring. (Plaster work 20 mm thick)
(Civil dept.SOR page no.143,Sr no.29 a )
100
-
598
b) Reinstatement work at meter room & pump room (Brick work)
(Civil dept.SOR,page no.23,Sr no.2b2)
10
-
5953
c) Reinstatement work by PCC (Concreting -Ratio 1:2:4)
(Civil dept. SOR page no.13,Sr no.1a2)
8
-
6285
Buyback
-
-
-
Buy Back of old and dismantled materials such as floroscent tubelight fittings, ceiling fan, switch boards, switch gears, point wiring, cables etc. ( One Lot ) (As per departmental rate analysis)
1
-
3666.3