Mumbai Port Trust Tender

... More
Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.

Mumbai Port Trust - MBPT Tender

Goods
GEM
Opening Date28 Mar 2025
Closing Date22 Apr 2025
Tender Amount₹ 32,22,750 
Notes
Download

Costs

Summary

BOQ Title: Renewing Electrical Installations in MBPA Hospital

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Wall socket outlet point, 3 pin and earth, 5A, 250 volts on control board as a half point by using 3 x 1.5 sq. mm 1100 V grade FR-PVC insulated copper conductor single core wire.

100

-

-

... More
Wiring in PVC casing & capping system using rigid PVC casing & capping, 3 X 2.5 sq. mm. (phase, neutral & earth wire), 1100V grade FR-PVC insulated copper conductor single core wires for four nos. socket outlet points on separate board, 5/6 pins, 5/15A, 230V modular type switch & socket, etc. as separate point using heavy duty (2.5mm approx.). Plastic/PVC box/ board with plastic/PVC cover plate, etc. Point wires to be tapped from the nearest M.C.B.D.B.

20

-

-

... More
Wiring in PVC casing & capping system using rigid PVC casing & capping, 3 X 2.5 sq. mm. (phase, neutral & earth wire), 1100V grade FR-PVC insulated copper conductor single core wires to be connected back to back connection to four no. socket outlet points on separate back to back boards, 5/6 pins, 5/15A, 230V modular type socket only by using heavy duty (2.5mm approx.) Plastic/PVC box/board with plastic/PVC cover plate, etc. Point wires to be tapped from the nearest TPN MCB DB as per site condition.

3

-

-

... More
Wiring in PVC casing & capping system using rigid PVC casing & capping, 3 X 2.5 sq. mm. (phase, neutral & earth wire), 1100V grade FR-PVC insulated copper conductor single core wires for three nos. socket outlet points on separate board, 5/6 pins, 5/15A, 230V modular type switch & socket, etc. by using heavy duty (2.5mm approx.) Plastic /PVC box/board with plastic/PVC cover plate, etc. Point wires to be tapped from the nearest TPN MCB DB.

20

-

-

... More
Wiring in PVC casing & capping system using rigid PVC casing & capping, 3 X 2.5 sq. mm. (phase, neutral & earth wire), 1100V grade FR-PVC insulated copper conductor single core wires for two nos. socket outlet points on separate board, 5/6 pins, 5/15A, 230V modular type switch & socket, etc. by using heavy duty (2.5mm approx.) Plastic /PVC box/board with plastic/PVC cover plate, etc. Point wires to be tapped from the nearest TPN MCB DB.

100

-

-

... More
Wiring in PVC casing & capping system using rigid PVC casing & capping, 3 X 4 sq. mm. (phase, neutral & earth wire) 1100V grade FR-PVC insulated copper conductor single core wires for 20A, 230V PVC Modular board comprising of 6/16A, 5 pin heavy duty socket with 20A SP MCB as a single unit in a heavy-duty PVC box for Air condition point.

55

-

-

... More
Wiring in PVC casing & capping system using rigid PVC casing & capping, 3 X 2.5 sq. mm. (phase, neutral & earth wire), 1100V grade FR-PVC insulated copper conductor single core wires for single socket outlet points on separate board, 5/6 pins, 5/15A, 230V modular type switch & socket, etc. by using heavy duty (2.5mm approx.) Plastic/PVC box/board with plastic/PVC cover plate, etc. Point wires to be tapped from the nearest TPN MCB DB.

30

-

-

... More
Wiring in PVC casing & capping system using rigid PVC casing & capping, 3 X 2.5 sq. mm. (phase, neutral & earth wire), 1100V grade FR-PVC insulated copper conductor single core wires for single socket outlet points on separate board, 5 pins, 5/6A, 230V modular type switch & socket, etc. by using heavy duty (1.5mm approx.) Plastic/PVC box/board with plastic/PVC cover plate, etc. Point wires to be tapped from the nearest TPN MCB DB.

25

-

-

... More
Wiring in PVC casing & capping system using rigid PVC casing & capping, 3 X 1.5 sq. mm. (phase, neutral & earth wire), 1100V grade FR-PVC insulated copper conductor single core wires for two nos. socket outlet points on separate board, 5 pins, 5/6A, 230V modular type switch & socket, etc. by using heavy duty (2.5mm approx.) Plastic/PVC box/board with plastic/PVC cover plate, etc. Point wires to be tapped from the nearest TPN MCB DB.

20

-

-

... More
Wiring in PVC casing & capping system using rigid PVC casing & capping, 3 X 1.5 sq. mm. (phase, neutral & earth wire), 1100V grade FR-PVC insulated copper conductor single core wires for three nos. socket outlet points on separate board, 5 pins, 5/6 A, 230V modular type switch & socket, etc. by using heavy duty (2.5mm approx.) Plastic/PVC box/board with plastic/PVC cover plate, etc. Point wires to be tapped from the nearest TPN MCB DB.

15

-

-

... More
Supply and delivery of Distribution board, three pole & neutral in sheet steel enclosure, powder coated, double door, vertical, MCCB as incomer 100A/125A, surface/recess mounting, fitted with pre-wired insulated tinned copper bus-bars, neutral links, DIN channels, earthing terminals/links, etc. suitable for housing SP/DP/TP/TPN MCB units but without MCCB/MCB/ RCCB/Isolator (TP & N incoming & TP & N outgoing).

-

-

-

... More
8 Way (8+24 way) (For D1 ward PDB No.1, 2 & 3).

3

-

-

... More
Installation of above double door sheet steel distribution boards at Sr. Nos. 13 on wall by using suitable required materials in D1 ward.

3

-

-

... More
Supply and delivery of Distribution board, Three pole & neutral, in sheet steel enclosure, powder coated, double door surface mounting, fitted with DIN channel, earthing terminal, etc. suitable for housing FP Isolator of various current carrying capacity units but without MCB/RCCB/ Isolator. (TP & N incoming & SP & N outgoing).

-

-

-

... More
4 Way (8+12 way)

7

-

-

... More
6 Way (8+18way)

5

-

-

... More
Installation of above double door TP&N incoming & single phase and N outgoing sheet steel distribution boards at Sr. Nos. 15 & 16 on wall by using suitable required materials.

12

-

-

... More
Supply and delivery of Distribution board, Three pole & neutral, in sheet steel enclosure, powder coated, single top fixing door, surface mounting, fitted with DIN channel, earthing terminal, etc. suitable for housing FP Isolator of various current rating units but without MCB/RCCB/Isolator .

-

-

-

... More
4 Ways D.B. For housing FP Isolator, TP & N 63A. Required for various distribution boards of Pathology lab.

5

-

-

... More
4 Ways D.B. For housing FP Isolator, TP & N 100A Required for UPS- I/c supply at MOT.

1

-

-

... More
Installation of above Three Pole and Neutral Distribution Boards at Sr. No. 18 & 19 on wall by using suitable required materials.

6

-

-

... More
Supply and delivery of Distribution board, single pole & neutral in sheet steel enclosure, powder coated, single door, surface/recess mounting, fitted with pre-wired insulated tinned copper bus bar, neutral link, DIN channel, earthing terminal, etc. suitable for housing SP/DP MCB units but without MCB/RCCB/Isolator.

-

-

-

... More
6 Way (2 + 4 way)

4

-

-

... More
8 Way (2 + 6 way)

1

-

-

... More
12 Way (2 + 10 way)

10

-

-

... More
16 Way (2 + 14 way)

5

-

-

... More
Installation of above Single Phase and Neutral Distribution Boards at Sr. No. 21, 22, 23 & 24 on wall by using suitable required materials.

20

-

-

... More
(A) Supply and delivery of MCB type Isolators DP / TP / FP of various current ratings for voltage up to 240/415V, AC Motor duty.

-

-

-

... More
FP Isolator 32A

3

-

-

... More
FP Isolator 40A

5

-

-

... More
FP Isolator 63A

8

-

-

... More
FP Isolator 80A

2

-

-

... More
FP Isolator 100A

10

-

-

... More
DP Isolator 32A

2

-

-

... More
DP Isolator 40A

15

-

-

... More
DP Isolator 63A

6

-

-

... More
DP Isolator 80A

2

-

-

... More
(B) Miniature Circuit Breakers (MCB) SP/DP/TP/TPN/FP units, "C" curve, motor duty of various current rating, A.C. supply .

-

-

-

... More
TP MCB 32A

8

-

-

... More
SP MCB 6A

28

-

-

... More
SP MCB 10A

16

-

-

... More
SP MCB 16A

78

-

-

... More
SP MCB 20A

40

-

-

... More
SP MCB 25A

24

-

-

... More
SP MCB 32A

64

-

-

... More
SP MCB 40A

10

-

-

... More
Installation, terminations, testing and commissioning of Sr. Nos. 26 to 42 SP/DP/TP/FP type MCB/Isolators of various current ratings in the above Distribution Boards at Sr. Nos. 13, 15, 16, 18, 19, 21, 22, 23 & 24 by using suitable required materials.

44

-

-

... More
Supply & Delivery of PVC/XLPE insulated armoured PVC sheathed cable of size, 3.5C x 50 sq.mm with Aluminium conductor heavy duty 1100 volts grade confirming to IS 1554/7098 (part-I) of 1988 (From Ground floor East Sw. Chamber to 1st floor Sw. Chamber)

100

-

-

... More
Installation, laying, testing and commissioning of Sr. No. 44 cable on wall by using suitable size of GI saddles & spacers.

100

-

-

... More
Supplying and making two (1 pair) ends of cable termination and connection with single compression type brass glands and copper lugs for the cable size: 3.5C x 50 sq. mm. PVC/XLPE - A-PVC cable with Aluminium conductor, 1100 volts grade as required.

2

-

-

... More
Supply & Delivery of PVC/XLPE insulated armoured PVC sheathed cable of size, 3.5C x 35 sq.mm with Aluminium conductor heavy duty 1100 volts grade confirming to IS 1554/7098 (part-I) of 1988 (From East Sw. Chamber 1st floor to Bus bar unit of Pathology + Emergency ward + D1 Wards, etc.)

300

-

-

... More
Installation, laying, testing and commissioning of Sr. No. 47 cable on wall by using suitable size of GI saddles & spacers.

300

-

-

... More
Supplying and making two (1 pair) ends of cable termination and connection with single compression type brass glands and copper lugs for the cable size: 3.5C x 35 sq. mm. PVC/XLPE - A-PVC cable with Aluminium conductor, 1100 volts grade as required.

6

-

-

... More
Supply & Delivery of PVC/XLPE insulated armoured PVC sheathed cable of size, 4C x 6 sq.mm with Copper conductor heavy duty 1100 volts grade confirming to IS 1554/7098 (part-I) of 1988. (From MOT Sw. Chamber to Emergency Ward+ outside of SOT Room + Nr. Shakti Clinic +MOT Ltg. MCBs)

150

-

-

... More
Installation, laying, testing and commissioning of Sr. No. 50 cable on wall by using suitable size of GI saddles & spacers.

150

-

-

... More
Supplying and making two (1 pair) ends termination and connection with single compression type brass glands and copper lugs for the cable size: 4C x 6 sq.mm. PVC/ XLPE--PVC cable with copper conductor, 1100 volts grade as required.

6

-

-

... More
Supply & Delivery of PVC/XLPE insulated armoured PVC sheathed cable of size, 4C x 10 sq.mm with Al. conductor heavy duty 1100 volts grade confirming to IS 1554/7098 (part-I) of 1988. (From Pathology bus bar chamber unit to Instrument Room TP&N MCB DB)

25

-

-

... More
Installation, laying, testing and commissioning of Sr. No. 53 cable on wall by using suitable size of GI saddles & spacers.

25

-

-

... More
Supplying and making two (1 pair) ends termination and connection with single compression type brass glands and copper lugs for the cable size: 4C x 6 sq.mm. PVC/ XLPE--PVC cable with copper conductor, 1100 volts grade as required.

1

-

-

... More
Supply and delivery of suitable size of MS angle frame (L-shape angle of size 50x50x5mm and MS flats of suitable size) to be grouted on wall and installation of existing Bus-bar unit along with I/C & O/G SFU units on it as per the instructions at Pathology Lab.

1

-

-

... More
Supply & delivery of Switch Fuse Unit in Sheet Steel enclosure, 100 Amps, 415 V, 3 Phase and Neutral, with 3 Nos. 100 Amps. HRC Fuses complete with Spreader Box at incoming end.

2

-

-

... More
Installation, testing & commissioning of above 100A SFU units on M.S. frame/wall by using suitable size of nut-bolts, screws, clamps, etc. and cable terminations as per the instructions.

2

-

-

... More
Supply & delivery of Switch Fuse Unit in Sheet Steel enclosure, 63 Amps, 415 V, 3 Phase and Neutral, with 3 Nos. 63 Amps. HRC Fuses complete with Spreader Box at outgoing end.

10

-

-

... More
Installation, testing & commissioning of above 63 Amp. SFU units on M.S. frame/wall by using suitable size of nut-bolts, screws, clamps, etc. and cable terminations as per instructions (for East Sw. Chamber at Gr & First floor pathology lab).

10

-

-

... More
Supply & delivery of Equal Section tin plated Copper Bus Bar panel. Indoor type fabricated out of 3 mm (approx.) thick sheet steel, 3 phase & neutral, 415 Volts, 50 Hz. A.C. supply having tinned copper bus bars of size 4 x (1000x50x5 mm) for neutral and Earthing terminal. Bus bar to be fixed on epoxy insulator with suitable knock outs for cable entry.

1

-

-

... More
Installation, fixing, testing & commissioning of above Bus Bar panel in the switch room on existing M.S. frame.

1

-

-

... More
Supply & delivery of Switch Fuse Unit in Sheet Steel enclosure, 400 Amps, 415V, 3 Phase and Neutral, with 3Nos. 400Amps. HRC Fuses complete with Spreader Box at incoming and outgoing end.

3

-

-

... More
Installation, testing & commissioning of above 400A SFU units on M.S. frame/wall by using suitable size of nut-bolts, screws, clamps, etc. and cable terminations as per instructions.

3

-

-

... More
Disconnection and reconnection of existing cable termination of size: 3.5Cx 400 sq.mm. PILSTA/ XLPE/PVC cables with Aluminium conductor, 1100 volts grade as required.

3

-

-

... More
Supply & delivery of Switch Fuse Unit in Sheet Steel enclosure, 125 Amps, 415 V, 3 Phase and Neutral, with 3 Nos. 125Amps. HRC Fuses complete with Spreader Box at incoming and outgoing end.

5

-

-

... More
Installation, testing & commissioning of above 125A SFU units on M.S. frame/wall by using suitable size of nut-bolts, screws, clamps, etc. and cable terminations as per instructions.

5

-

-

... More
Disconnection and reconnection of existing cable termination of various sizes of cables with PVC/XLPE cable with Aluminium/Copper conductor, 1100 volts grade as required by using suitable size of single compression glands and lugs.

-

-

-

... More
3.5C x70 sq. mm. Al.

3

-

-

... More
3.5C x 50 sq. mm. Al.

4

-

-

... More
3.5C x 35 sq.mm. Al

2

-

-

... More
4C x 35 sq.mm. Al

4

-

-

... More
4C x 25 sq.mm. Al.

6

-

-

... More
4C x 10 sq.mm. Al.

8

-

-

... More
3C x 6 sq.mm. Cu.

4

-

-

... More
Supply & delivery of LED tube light fitting, commercial power coated CRCA sheet steel box type 1200 mm (approx.) long, ceiling / wall mounting with 2 X 18/20 W LED tube, pre-wired with driver etc. connector, side holders and interconnecting wiring by using 2/3 core X 0.75 sq.mm. PVC/ PVC flexible copper conductor wire, etc. as required

235

-

-

... More
Installation, fixing, testing & commissioning of above LED tube light fittings at Sr. No. 75 by using clamps, nut & bolts including mounting arrangement of standard down rods, ball & sockets arrangement, etc.

235

-

-

... More
Supply & delivery of LED tube light fitting, indoor decorative PVC/Polycarbonate/CRCA housing box type 1200 mm (approx.) long, ceiling / wall mounting with 2 X 18/20 W LED tubes, pre-wired with, driver etc. connector, side holders, Opel acrylic/ Polystyrene diffuser, plastic end caps & interconnecting wiring by using 2/3 core X 0.75 sq.mm. PVC/ PVC flexible copper conductor wire, etc. as required

60

-

-

... More
Installation, fixing, testing & commissioning of above LED tube light fittings at Sr. No. 77 by using clamps, nut & bolts including mounting arrangement, standard down rods, ball & sockets arrangement, etc.

60

-

-

... More
Supply & delivery of Pedestal air circulator, heavy duty oscillation type, 600 mm (24") dia.1400 RPM (approx..) suitable for single phase, 230V, 50Hz, A.C. supply operation complete with sturdy metal body and blades, metal guard, metal adjustable stand with base, interconnecting wiring/cord, etc. as required.

35

-

-

... More
Supply & delivery of BLDC Ceiling fan, 1200 mm sweep, suitable for single phase, 230V, 50Hz, A.C. supply operation complete with accessories such as standard down rod, canopies, inter connecting wiring using 2/ 3 core X 0.75 sq.mm. PVC / PVC flexible copper conductor wire & remote.

180

-

-

... More
Installation, testing & commissioning of above BLDC Ceiling fans at Sr. No. 80 by using suitable clamps, Anchor fasteners, etc. as per requirement.

110

-

-

... More
Installation, testing & commissioning of above BLDC Ceiling fans at Sr. No. 80 by using suitable clamps, Anchor fasteners above fall ceiling, etc. as per requirement.

70

-

-

... More
Supply & delivery of Exhaust Fan domestic type, 300mm (12”) dia. Suitable for single phase, 230 volt, 50 Hz. A.C. supply operation complete with rust proof metal body and blades, louvers, interconnecting wiring/ cord, etc.

20

-

-

... More
Installation, testing & commissioning of above Exhaust fans using suitable GI clamps /GI strips of heavy duty size/ nut- bolts, Screws, anchor fasteners, etc. Closing the exhaust fan opening/ side gaps properly by using heavy duty marine ply after installation of Exhaust fan complete as per instruction.

20

-

-

... More
Supply & delivery of Storage type water Geyser 35 Litre capacity, suitable for single phase 230 volts operation having inner & outer container rust proof body, corrosion resistant inner container, heating element with high pressure cut off. All safety against high temperature & pressure with cut out, thermostat & safety valve devices & standard accessories complete as per requirement.

6

-

-

... More
Installation, testing & commissioning of storage type water Geyser at above at Sr. No. 85 Including incoming and outgoing water supply line connection as per requirement at site complete.

6

-

-

... More
Supply & delivery of Fly Kill lite units single phase 230 volt with two nos. tubes.

2

-

-

... More
Installation, testing & commissioning of above item at Sr. No. 87 on ceiling by using clamps, nut & bolts including mounting arrangement of standard down rods, ball & sockets, etc.

2

-

-

... More
Supply & delivery of LED warm type round light 12 watt fittings with driver, lamp, single phase, 230 volt for wash basin/ mirror light.

16

-

-

... More
Installation, testing & commissioning of above item at Sr. No. 89 on ceiling/wall by using suitable size of clamps, nut & bolts, etc.

16

-

-

... More
Supply & delivery of LED tube light fitting indoor decorative PVC/Polycarbonate box type 300 mm (approx.) long, ceiling / wall mounting with 1 X 9 W or suitable wattage LED tube, pre-wired with, driver etc. connector, side holders, Opel acrylic/Polystyrene diffuser, plastic end caps & interconnecting wiring by using 2/3 core X 0.75 sq.mm. PVC/ PVC flexible copper conductor wire, including mounting arrangement as required.

10

-

-

... More
Installation, testing & commissioning of above item at Sr. No. 91 on wall/ ceiling by using suitable size of clamps, screws, nut & bolts, etc.

10

-

-

... More
Disconnecting and dismantling the existing electrical installations (i.e. Emergency ward, ICU, SOT Room, MOT 2 & 3, D1 Ward, Gynac OPD, Family Planning OPD’s, Pathology Labs & Administrative office, etc.) such as point wiring, cables, DB, switch boards, light fitting, fan wiring between the cut-outs, DP switches, Isolator, MCB units, etc. as required from the site and handing over to the store at EEWA.

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.