Mumbai Port Trust Tender
Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.
Mumbai Port Trust - MBPT Tender
Housekeeping Services
Eprocure
Opening Date9 Nov 2020
Closing Date15 Dec 2020
Tender AmountRefer Documents
Costs
EMD
₹ 5,74,950Document Cost
₹ 5,250Tender Fee
Refer Documents
Summary
Meed 18/2020 - Boundary Wall Lighting
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2020_MBPT_595807_1Bid Award Id
ViewTender No
MEED 18/2020Tender Authority
Mumbai Port Trust ViewPurchaser Address
-Website
http://http://www.mumbaiport.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Installation of street light bracket at Sr. No.2 above on the stone boundary wall with suitable S.S. clamps & S.S. nut bolts of grade 304 & fixing LED street light fitting at Sr. No.1 above with suitable mounting arrangement etc. and to the instructions.
650
-
-
Wiring for the LED luminary at Sr. No.1 through the bracket mentioned at Sr. No.2 from cable looping box provided on the boundary wall by using 48/0.2 mm ( 1.5 sq. mm), 3 core PVC/PVC flexible copper conductor cable including connecting both the ends by using lugs and glands and to the instructions.
650
-
-
Supply and Delivery of outdoor type cable looping box made out of Sheet Moulding Compound (SMC), IP 65. The looping box must be of appropriate size and accommodated with 01 No SP MCB-06 Amp and 4 way connector suitable for 4C x 4mm² copper conductor armoured cable loop In/Out with necessary clearances, with interconnecting wiring for MCB by using PVC insulated PVC sheathed or sleeved copper conductor wires, with provision for 03 or 04 no. glands out of which 1gland for 3cx1.5 mm² cable & 2 or 3 nos. double compression glands for 4Cx4mm²copper conductor armoured cable for looping box with suitable mounting arrangement.
650
-
-
Installation of the cable Looping Box at Sr. No.5 on the stone boundary wall at a height of 3.5 meters approx. from the ground level and to the instructions.
650
-
-
Supply & delivery of XLPE insulated armoured PVC sheathed cable of size 4C x4 sq. mm. with copper conductor heavy duty 1100 volts grade conforming to IS 1554/7098(part-I) of 1988. (approx.)
10000
-
-
Supply and delivery of Hot Dip G. I wire of size 12 SWG for earthing.
10000
-
-
Laying of Cable mentiond at Sr. No. 7 & Hot Dip G. I wire at Sr. No. 8 on the Stone Dock Boundary wall by using adequate No. of spacers/ L-clamps and saddles of suitable size made out of S.S.304 material from Lighting control panel to 1st looping box & 1st looping box to the last looping box of different circuits and to the instructions.
9700
-
-
Supply, Delivery and making of two (1 pair) ends of cable termination and connection both end with double compression type high quality nickel plated brass gland including brass lock nuts, internal gasket and ingress protection IP66 and Copper lugs for item at Sr. No. 7 from looping box to looping box.
625
-
-
Supply and Delivery of hot dip GI pipe of dia. 1½" and each of 3 meter length.
14
-
-
Supply, Delivery and making of two (1 pair) ends of cable termination and connection both end with high quality nickel plated brass gland including brass lock nuts, internal gasket and ingress protection IP66 and Copper lugs for item at Sr. No.7 by using hot dip G.I. pipe at Sr. No.11 for cable protection to be provided on wall for threading the cable from control panel upto the 1st looping box.
30
-
-
Supply & delivery of XLPE insulated armoured PVC sheathed cable of size 4C x10 sq. mm. with copper conductor heavy duty 1100 volts grade conforming to IS 1554/7098(part-I) of 1988. (approx.)
500
-
-
Excavating & backfilling suitable trench as per specifications in any type of soft soil / asphalt / concrete / stone including cleaning the cable trenches for LT Cable at Sr No. 7 & 13 above and removing all surplus excavated earth from site to the satisfaction of MbPT Site Engineer as required.
250
-
-
Laying of LT cable mentioned at Sr. No. 7 & 13 in trench including drawing the cable, dressing the cable, protection to the cable in trench by providing soft screened earth/sand upto a height of 100 mm below the cable and 150 mm above the cable and placing whole red bricks all along the run of the cable and removing all surplus excavated earth from site to the satisfaction of MbPT Engineer as requied.
550
-
-
Laying of Cable mentiond at Sr. No. 13 & Hot Dip G. I wire at Sr. No. 8 on the Stone Dock Boundary wall/ Brick wall/ Beams/Columns/DWC HDPE pipe by using adequate No. of spacers/ L-clamps and saddles of suitable size made out of S.S. 304 material complete from nearest supply source to street light control panel to the instructions.
200
-
-
Supply and Delivery of (DWC) HDPE pipe of size 40 mm dia. of approved quality. (optional)
90
-
-
Laying (DWC) HDPE pipe at Sr. No.17 through the duct from FP-2A (Near DCT) to Boundary wall and as directed but excluding excavation.(optional)
90
-
-
Supply, Delivery and making of two (1 pair) ends of cable termination with one end double compression high quality nickel plated brass gland including brass lock nuts, internal gasket and ingress protection IP66 and Copper lugs and other end with single compression type brass gland and connections with copper lugs for following size of XLPE insulated armoured cable 4Cx10 sq. mm with copper conductor,1100 volts grade by using suitable hot dip G.I. pipe of suitable length for cable protection to be provided on wall and at source of supply for threading the cable from main supply source to street light control panel and to the instructions.
16
-
-
Supply & delivery of boundary wall light control panel made out of S.S. enclosure grade 304, 18 gauge, IP 66, internally embedded gasket with provision for cable entry through glands. The control panel must be of appropriate size to accommodate the following switch gears with interconnecting wiring between the switchgear by using PVC insulated PVC sheathed or sleeved copper conductor wires / busbar. The control panel shall be provided with canopy, necessary locking arrangement and pedastal mounting type on hot dip G.I frame of suitable height and shall comprise of the following items with necessary clearances. 1) Switch Fuse Unit (32 A)- 01 No, 2) Analog Timer 24 Hrs - 01 No, 3) TP Contactor 40A with 230 V operating coil-01 No, 4) Digital Multi Function Meter( Next Gen)- 01 No, 5) FP MCB 20A-04 Nos. 6) Auto/ Manual selector switch 6A-01 No, 7) Connectors: 1 set-4Nos for 4Cx10 mm² (I/C) cable and 4sets each of 04 Nos. for 4Cx 4 mm² (O/G) cables, 8) Provision for Earthing connection to the control panel. 9) Door operated LED Panel light of 5 watt, 230 V. The Manufacturer shall submit a copy of test report for degree of ingress protection as per IEC 60529.
8
-
-
Installation of Boundary wall light control panel at Sr. No.20 as per instructions.The frame shall be grouted in the ground with cement concrete prepared out of cement mortar of M20 grade (1:1.5:3) as per specifications and to the instruction.
8
-
-
Supply & delivery of outdoor type control panel made out of S.S. enclosure, grade 304, 18 gauge, IP 66, internally embedded gasket with provision for cable entry through glands. The control panel must be of appropriate size to accommodate the following switch gears with interconnecting wiring between the switchgear by using PVC insulated PVC sheathed or sleeved copper conductor wires / busbar. The control panel shall be provided with canopy, necessary locking arrangement and wall mounting type on hot dip G.I frame of suitable size and shall comprise of the following items with necessary clearances. 1) FP MCB-20 A- 01 No (I/C), 2) FP MCB-10 A- 02 No (O/G), 3) Analog Timer 24 Hrs - 01 No, 4) TP Contactor 25 A with 230 V operating coil-01 No, 5) Digital Multi Function Meter( Next Gen)- 01 No, 6) Auto/ Manual selector switch 6A-01 No, 7) Connector 1set-4 Nos for 4Cx10 mm² (I/C) and 02 sets each of 4 Nos. for 4Cx 4 mm² (O/G) cables, 8) Provision for Earthing connection to the control panel, 9) Door operated Panel LED light of 5watt, 230 V. Manufacturer shall submit a copy of test report for degree of ingress protection as per IEC 60529.
6
-
-
Installation of Boundary wall light control panel at Sr. No.22 as per instructions.The frame shall be grouted on the wall with cement concrete prepared out of cement mortar of M20 grade (1:1.5:3) as per specifications and to the instruction.
6
-
-
Installation, Testing and Commissioning of Earthing pit by auguring and installation of Copper Coated electrolytically bonded 250 micron GI Earth Rod of 17.2 mm dia. 3 mtr long Earth enhancement compound 25 Kg , connector for testing link complete with inspection chamber made out of brick masonry and cast iron inspection cover duly painted and marked. The resistance of earthing station shall be tested with calibrated Earth Resistance Tester and results recorded as required for High Mast, High Mast Control Panel & Boundary wall Light Control Panel by using 2 Nos. G.I. earthing strips of size 25x3mm (approx.) complete with providing grid earthing between earth electrode to High Mast and High Mast Control Panel, Boundary wall Light control panel.
16
-
-
Supply and delivery of GI Strip of size 25 mm x 3 mm. (approx.)
110
-
-
Installation, connection of GI strip supplied at Sr. No. 25 as strip earth electrode, including connection / terminating with G.I. nut- bolt, S.S. spring/plain washer etc. as required. (approx.)
16
-
-
Dismantling/Removal of existing boundary wall light fittings / fixtures, control gear boxes, M.S. Boxes, light distribution boxes, brackets, clamps, looping boxes, old wiring, cables, accessories and other materials etc.
1
-
-
Lowering down the Lantern Carriage of 40 Meter High Mast located near Domestic Cruise Terminal (between 14VD & DCT), near lock gate & BPX, Disconnecting & removing the existing HPSV light fittings & control gear boxes from the electric supply to the instructions including overhauling of mechanism of High Mast. The cost of gear required if any is deemed to be included in the item rate.
3
-
-
Supply and Delivery of 350 W LED flood Light Fitting for High Mast at Sr. No.28 above as per specifications of LED enclosed at Annexure - I(12 Nos fittings each High Mast Tower).
36
-
-
Wiring for the LED luminary at Sr. No.29 above on the High Mast at Sr. No. 28 by using 48/0.2 mm ( 1.5 sq. mm), 3 core PVC/PVC flexible copper conductor cable including connecting both the ends. The work includes interconnecting wiring between luminaries and junction box/ boxes/ distribution boards etc.
3
-
-
Installation, testing and commissioning of item mentioned at Sr. No.29 by using suitable hot dip GI Clamps & nut bolts.
3
-
-
Lowering down the Lantern Carriage of 20 Meter High Mast located near Orange Gate Princess Dock, Disconnecting & removing following existing items like 1) HPSV light fittings, gear boxes, JB's DB's, 2) Head Frame 3) Lantern carriage, 4) Wire ropes, 5) Trailing cable, 6) Double drum winch etc.
1
-
-
Supply and Delivery of following items for High Mast at Sr. No. 32 above like 1) Suitable Head frame, 2) Suitable size and length of SS-316 wire ropes, 3) Appropriate size EPR insulated PCP sheathed trailing cable with copper conductor, 4) Suitable Double drum winch, 5) Galvanized Lantern carriage suitable for 10 Nos of 250 W LED luminaries, 6) FPMCB 20 Amp, 7) Hardware required for light fittings 8) Double drum winch Motor with starter etc.
1
-
-
Supply and Delivery of 250 W LED flood Light Fitting for 20 Meter High Mast at Sr. No.32 above. Specifications of LED is enclosed at Annexure - I.
10
-
-
Wiring for the LED luminary at Sr. No.34 above on the High Mast at Sr. No.32 by using 48/0.2 mm ( 1.5 sq. mm), 3 core PVC/PVC flexible copper conductor cable including connecting both the ends. The work includes interconnecting wiring between luminaries and junction box/ boxes/ distribution boards etc.
1
-
-
Installation, testing and commissioning of items mentioned at Sr. No.33 & 34 above on the High Mast at Sr. No.32.
1
-
-
Shifting of 01 No. 20 M High Mast from SRF building to Parking space near Gamadia Road.
1
-
-
Supply and Delivery of following items for High Mast to be installed at Parking space Near Gamadia Road like 1) Suitable Head frame, 2) Suitable size and length of SS-316 wire ropes, 3) Appropriate size EPR insulated PCP sheathed trailing cable with copper conductor, 4) Double drum winch, 5) Galvanized Lantern carriage arrangement suitable for 10 Nos of 250 W LED luminaries, 6) FPMCB- 20 Amp, 7) Hardware required for light fittings 8) Double drum winch Motor with starter etc.
1
-
-
Installation of accessories at Sr. No. 38 above on the High Mast at Sr. No. 37 and reconditioning the surface of this High Mast and providing double coat of Metalic Silver Paint of thickness not less than 70 microns.
1
-
-
Shallow foundation with M-25 concrete and re-enforcement of suitable size considering the safe soil bearing capacity of 5T/sq. meter at 1.5-meter depth at site. The cost quoted shall be inclusive of excavation and backfilling of the area as required.
The successful bidder has to prepare the structural design & drawing for construction of foundations for High mast tower (20 mtrs height) through MCGM registered (Licensed) Structural Engineer and submit the foundation drawing for approval. The submitted drawing shall be approved by the Civil Engineering Department, MbPT. The construction of foundation shall be carried out only as per the approved drawing, incorporating changes as suggested by MbPT, if any. ( For high mast at Gamadia Parking space)
1
-
-
Supply of foundation bolts manufactured from steel of suitable size along with nuts & washers (hot dip galvanized), adequate size of anchor plates and templates etc. for providing foundation of high mast at Gamadia Parking space.
1
-
-
Supply and Delivery of 250 W LED flood Light Fitting for 20 Meter High Mast at Sr. No.37. Specifications of LED is enclosed at Annexure - I.
10
-
-
Installation, testing and commissioning of Symmetrical high mast system of 20 mtr height with its accessories mentioned at Sr. No.38 & 42. The mast shall have an integral power tool installed inside the base compartment for its operation. The erection of high mast with the help of suitable tools and plants. Installation and wiring of luminaries with all wiring materials like PVC insulated, PVC sheathed flexible cable of suitable copper conductor cores of suitable size, lugs, MCB’s etc. The work also includes interconnecting wiring between luminaries and junction box/ boxes/ distribution boards by using appropriate size and grade of PVC insulated / armoured copper conductor wires / cables etc.
1
-
-
Supply & delivery of outdoor type High Mast Control panel made out of SS enclosure grade 304, 18 gauge, IP 66, internally embeded gasket with provision for cable entry through glands. The control panel must be of appropriate size to accommodate the following switch gears with interconnecting wiring between the switchgear by using PVC insulated PVC sheathed or sleeved copper conductor wires / busbar. The control panel shall be provided with canopy, necessary locking arrangement and pedestal mounting type on hot dip G.I frame of suitable size and shall comprise of the following items with necessary clearances. 1) Switch Fuse Unit 32 Amp-01 No, 2) FP MCB-20 A- 02 No (O/G), 2) Analog Timer 24 Hrs - 01 No, 3) TP Contactor 40 A with 230 V operating coil-01 No, 4) Digital Multi Function Meter( Next Gen)- 01 No, 5) Auto/ Manual selector switch 6A-01 No, 6) Connector 1 set of 4 Nos. for 4Cx10 mm² (I/C) cable and 02 sets of 04-Nos. for 4Cx4 mm² (O/G) cables, 7) Provision for Earthing connection to the control panel, 8) Door operated LED Panel light of 5watt, 230 V. Manufacturer shall submit a copy of test report for degree of ingress protection as per IEC 60529.
4
-
-
Installation of High Mast control panel at Sr. No. 44 The frame of the control panel shall be grouted in the ground with cement concrete prepared out of cement mortar of M20 grade (1:1.5:3) as per specifications and to the instructions.
2
-
-
Providing rail guard to the high mast tower by using M.S. ‘I’ channel of size 100 mm X 50 mm comprising 04 Nos. vertical members and 04 Nos. horizontal members constructed/joined by nut bolts/ using welding complete as per instructions and grouting by c.c. foundation complete.
4
-
-
Supply of two Nos. LED type aviation obstruction lights.
8
-
-
Installation of aviation obstruction lights at Sr. No.47
8
-
-
Lowering down the Lantern Carriage of 20 Meter High Mast located In- Front of M-Shed (1-South & 1-North) , Disconnecting & removing the existing HPSV light fittings, control gear boxes, Head Frame, Lantern Carriage, EPR trailing cable, Double Drum winch, wire ropes etc. The cost of gear required if any is deemed to be included in the item rate.
2
-
-
Supply and Delivery of following items for High Masts at Sr. No. 49 above like 1) Suitable Head frame, 2) Suitable size and length of SS-316 wire ropes, 3) Appropriate size EPR insulated PCP sheathed trailing cable with copper conductor, 4) Suitable Double drum winch, 5) Galvanized Lantern carriage suitable for 10 Nos of 250 W LED luminaries, 6) FPMCB- 20 Amp, 7) Hardware required for light fittings 8) Double drum winch Motor with starter etc.
2
-
-
Supply and Delivery of 250 W LED flood Light Fitting for High Masts at Sr. No. 49. Specifications of LED is enclosed at Annexure - I.
20
-
-
Wiring for the LED luminary at Sr. No.51 above for the High Mast at Sr. No. 49 by using 48/0.2 mm ( 1.5 sq. mm), 3 core PVC/PVC flexible copper conductor cable including connecting both the ends. The work includes interconnecting wiring between luminaries and junction box/ boxes/ distribution boards etc.
2
-
-
Installation, testing and commissioning of items mentioned at Sr. No.50 &51 above on the High Masts at Sr. No.49.
2
-
-
Lowering down the Lantern Carriage of 20 Meter High Mast located near SRF Building, Disconnecting & removing following existing items like 1) Head Frame 2) Lantern carriage, 3) Wire ropes, 4) Trailing cable, 5) Double drum winch etc. The cost of gear required if any is deemed to be included in the item rate.
1
-
-
Supply and Delivery of following items for High Mast at Sr. No. 54 above like 1) Suitable Head frame, 2) Suitable size and length of SS-316 wire ropes, 3) Appropriate size EPR insulated PCP sheathed trailing cable with copper conductor, 4) Suitable Double drum winch, 5) Galvanized Lantern carriage suitable for 10 Nos of 250 W LED luminaries, 6) FPMCB- 20 Amp, 7) Hardware required for light fittings 8) Double drum winch Motor with starter etc.
1
-
-
Supply and Delivery of 250 W LED flood Light Fitting for 20 Meter High Mast at Sr. No.54 above. Specifications of LED is enclosed at Annexure - I.
10
-
-
Wiring for the LED luminary at Sr. No.56 above on the High Mast at Sr. No.54 by using 48/0.2 mm ( 1.5 sq. mm), 3 core PVC/PVC flexible copper conductor cable including connecting both the ends. The work includes interconnecting wiring between luminaries and junction box/ boxes/ distribution boards etc.
1
-
-
Installation, testing and commissioning of items mentioned at Sr. No.55 &56 above on the High Mast at Sr. No.54.
1
-
-
Removing the existing HPSV flood light fittings and their control gear boxes, existing wiring, JB's, DB's etc.installed on the terraces of buildings viz. P & V sub-station, P & V stone building, Hydraulic Building, Ambedkar Bhavan, Yantra Bhavan, Hamallage Building, SMRS, Princes Dock ware Houses etc.
1
-
-
Supply and Delivery of 300 W LED flood Light Fittings for installing on the terraces of various buildings inside Docks for improving the illumination. Specifications of LED is enclosed at Annexure - I.
65
-
-
Supply & delivery of Terrace Light control panel made out of S.S. enclosure grade 304, 18 gauge, IP 66, internally embedded gasket with provision for cable entry through glands. The control panel must be of appropriate size to accommodate the following switch gears with interconnecting wiring between the switchgear by using PVC insulated PVC sheathed or sleeved copper conductor wires / busbar. The control panel shall be provided with canopy, necessary locking arrangement and wall mounting type on hot dip G.I frame of suitable height and shall comprise of the following items with necessary clearances. 1) FP MCB-20 A- 01 No (I/C), 2) FP MCB-10 A- 02 No (O/G), 3) Analog Timer 24 Hrs - 01 No, 4) TP Contactor 25 A with 230 V operating coil-01 No, 5) Auto/ Manual selector switch 6A-01 No, 6) Connector 3 sets each of 4 Nos for 4Cx4 mm² cable (1No. I/C & 2 No. O/G), 8) Provision for Earthing connection to the control panel. Manufacturer shall submit a copy of test report for degree of ingress protection as per IEC 60529.
7
-
-
Installation of Terrace Light control panel at Sr. No. 61 with suitable mounting arrangement. and to the instructions.
7
-
-
Installation, Testing and commissioning of the LED flood light fittings at Sr. No.60 above on the Parapet Wall of the terraces, on the existing mounting frames of the following buildings viz. P & V sub-station, P & V stone building, Hydraulic Building, Ambedkar Bhavan, Yantra Bhavan, Hamallage Building, SMRS, Princes Dock ware Houses by using XLPE insulated armoured PVC sheathed cable of size 4C x 4 sq. mm. and 3C x 1.5 sq. mm with copper conductor heavy duty 1100 volts grade. The work includes supply of Hardware/mouting accessories of light fittings, junction boxes, distribution boxes/boards, suitable cable glands & inerconnecting wiring between luminaries and junction boxes, Junction boxes to Junction boxes and Junction boxes to distribution boards, tapping the electric supply from the nearest source of supply and connecting both the ends etc. and to the instructions.
65
-
-
Buyback
-
-
-
Buyback of following old removed material like old HPSV fittings, M.S. boxes and cable looping boxes of boundary wall lighting at Sr. No. 27 above and HPSV light fittings, control gear boxes, Head Frames, Lantern Carriages, EPR trailing cables, Double Drum winches, wire ropes etc. of high masts at Sr. No. 28,32,49, 54 above and HPSV flood light fittings and their control gear boxes, existing wiring, JB's, DB's etc.installed on the terraces of various buildings of MbPT.
-
-
-
HPSV flood light fitting (Twin) 2x400W with control gear box (Approx)
85
-
-
HPSV flood light fitting (Single) 400W with control gear box (Approx)
32
-
-
HPSV Street light fittings 125/150W (Approx)
154
-
-
Head Frames, Lantern Carriages, EPR trailing cables, Double Drum winches, wire rope set of High Mast.
5
-
-
M.S. boxes of boundary wall lighting (Approx)
10
-
-
Existing old wiring, JB's, DB's, cable looping boxes etc. of boundary wall lighting and terrace lighting.
1
-
-