Military Engineer Services Tender

... More
The MES has issued a formal invitation for competitive bids for the Military Engineer Services project, for 8229 Repairs To Roof Treatment Roof Covering Chhajja Facia And Structural Repair To Various Buildings In Zone 4 5 In Nd Mb Under Age Br1 Under Ge Nw Kunjali in Mumbai, Maharashtra, with an estimated contract value of Rs. 32,36,935. The bid opening date for this tender is 10-09-2019 and the last date for bid submission is 10-10-2019. Interested bidders for Military Engineer Services tender can download the important documents here to check the scope of work, eligibility criteria and technical requirements.

Military Engineer Services - MES Tender

Opening Date10 Sep 2019
Closing Date10 Oct 2019
Tender Amount₹ 32,36,935 
This is an estimated amount, exact amount may vary.
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
All as per Srl item No. 50 here in here in before but 1000 liter capacity.

3

-

-

... More
Dismantling wrought iron or mild steel works of any description work etc. complete all as specified and as directed.

6

-

-

... More
M & L for TMT mild steel bars,10 mm dia and over, cut to length bent to shape required, including cranking bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality conforming to Fe-410-S or Fe-410-0 complete all as specified and as directed.

230

-

-

... More
All as per item No. 26 above but plain sheets as in ridges / flashing.

20

-

-

... More
Dismantling Single layer Mangalore pattern or similar tiles in roofing complete all as specified and as directed.

160

-

-

... More
Taking down rain water pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-neck,etc. complete all as specified and as directed. (measured over all as fixed along the centre line over fittings and accessories)

120

-

-

... More
M&L for taking down, chipping and removing the loose, spilt, damaged cement concrete, cement mortor surfaces of RCC Columns, beams, walls, chajjah etc and exposing the reinforced cement, wire brushing and cleaning the exposed steel reinforced bar, applying rust remover over the cleaned re-bar surface wash the re-bar with clean water for removing all rusts from the old re-bar surfaces, fixing new reinforcement for strengthen the members as required, applying two coats of epoxy zinc primer on new and old steel surfaces, saturate the substrate with water applying one coat of polymer modified bond coat on affected concrete surfaces and finally providing polymer modified cement and quartz sand mortor in CM 1:3 mix , 40mm thk in two coats, using polymer as per manufacturer's instructions complete all as specified and directed. Make : Dr. Fixit/Sunanda/chemestik/Fosrok Note :- New reinforcement and MS Sections will be measured and paid separately

600

-

-

... More
Supply only polymer SBR Latex or equivalent as approved. Make:- Dr. Fosrok, Sunanda, Dr. Fixit

50

-

-

... More
S&F for mild steel plates of Grade Fe 410-W, (Gde- E-250) quality-A as in connecting pletes, base plate etc. welding etc. complete all as specified and as directed.

200

-

-

... More
M&L for the roof surface thoroughly wire brushed, washed and dried up and cleaned of all foreign matter and dust to receive bituminous primer, apply bituminous based cold applied primer @ 270 to 300 gms/Sqm manufactured by the same agency as that of APP all as per manufacturers instructions. Laying 5 layered, 4 mm thick APP (A tactic poly propylene) modified membrane reinforced with 180 GSM (Gms/Sqm) of non woven polyester mat, applied by thermo fusion using LPG torch on the bottom portion of the membrane with an overlap of 75mm in longitudinal direction. Add Note : Rates quoted shall be including disconnecting & refixing of existing AC outdoor units/lighting conductor/lighting arrester / or any other obstructing material etc if required as per site condition complete all as specified

2000

-

-

... More
M&L for rendering 5 mm thick in CM 1:3 on fair faces of brick work or concrete surfaces in ceiling finishing the surface even and smooth with and including 1mm thick sagol finish complete all as specified and directed.

70

-

-

... More
M&L for plastering in CM 1:4, 20 mm thick in two coats (15 mm under coat plus 5mm finishing coat) with water proofing compound at the rate of 2% by weight of cement and finishing the surface seven and fair complete all as specified and as directed. Note:-WPC will be measured and paid for seperately.

150

-

-

... More
Demolition of plain cement concrete of any description and in any position and remove debris outside from MD land complete all as specified and as directed.

90

-

-

... More
Dismantling wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/ any thickness, including cover fillets complete all as specified and as directed.

70

-

-

... More
S&F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed.

250

-

-

... More
M&L for brick work with sub class 'B' bricks straight or curved on plan exc 6 m mean radius and built in CM (1:6) complete all as specified and as directed.

5

-

-

... More
S&F 3 mm thick Aluminium composite panel cladding plain of approved colour/ shade to beam / column / slab in circular / rectangular shape including cutting, notching, bending to shape as required jointing with silicon gel of approved colour & Aluminum tubular hallow section 25 x 25 mm not exceeding 900 mm c/c on exceeding col/beam/ slab to hold APC cladding etc. complete all as specified and as directed. (Note:- Colour / Pattern of ACP sheet shall be given by GE)

10

-

-

... More
Making the Chajjah tops surface clean, free from dust dirt, grease, oil, followed by applying 2 coats of approved Rubberized / polymer water proofing treatment POLY ALK WP or equivalent of approved make as per the manufacturer’s specifications as specified and directed.

80

-

-

... More
Disconnecting existing tanks, exc. 500 & n exc. 1000 liters capacity, setting aside (or lowering if required) for repair, cleaning, etc and hoisting if required reconnecting and re-fixing in position complete all as specified and as directed.

5

-

-

... More
M&L for preparation of new steel surfaces exc 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed .

60

-

-

... More
M&L for preparation of newly plastered wall surfaces, over 10cm girth, applying two coats of 100% acrylic, weather resistant emlusion over a coat of exterior wall primer complete all as specified and as per manufacturer's instruction.

150

-

-

... More
S&F 6mm thick asbestos cement, corrugated or semi-corrugated sheets fixed with L-type or J-type or cranked hook bolts in roofs, walls complete all as specified and as directed.

100

-

-

... More
All as per Srl item No.50 here in here in before but 2000 liter capacity.

2

-

-

... More
M&L for 1.5 mm thick galvanised steel sheet as in valley gutters fixed with rivets or other suitable arrangements over MS brackets Trapezoidal shape of required profile with desired slope etc. at any height including dismantling of old valley gutters complete all as specified and as directed.

160

-

-

... More
S&F 160mm dia PVC (SWR) grade pipes single socketed in any length with rubber ring joints fixed to walls with and including fixing clips, bends, elbow, shoes bends etc. complete all as specified and as directed. (Note:- Measurment shall be taken along the centre line of the pipes.)

120

-

-

... More
M&L for erection & dismantling of MS tubular double scaffolding (H frame) upto height of 30m & with necessary brazing, provision of necessary safety equipment to the skilled workers to carry out the work and covering with green cloths for carrying out external face work of walls all as dpecified and as directed.

200

-

-

... More
M&L for preparation of newly plastered surfaces of wall & ceiling applying two coats of oil emlusion distemper over a coat wall care putty of 3mm thick and alkali primer complete all as specified and as directed.

170

-

-

... More
Dismantling plain or corrugated steel sheeting any guage, thickness, including Nainatal or similar pattern roof coverings complete all as specified and as directed.

370

-

-

... More
M&L for providing grouting 12 mm dia holes of 75mm deep @0.6 m c/c at junction of beams and columns as co-ordinal points for inserting/pouring mixture of Lw+, high proof chemicals and cement slurry by pressure grouting for column, beams and slabs, includind sealing the holes with CM 1:3, complete all as specified and as directed.

70

-

-

... More
S&F rotational moulded polyethylene water storage tanks of capacity 500ltr (cylindrical vertical with closed top) hoisted and fixed in position including dismantling of existing tanks and remove from site complete all as specified and as directed.

5

-

-

... More
All as per Srl item No. 19 here in before but 40mm dia medium GI Pipe.

20

-

-

... More
Taking down 25 mm bore, GI tubing and connections including cleaning for refixing or removal from site complete all as specified and as directed.

20

-

-

... More
S&F 25 mm dia medium grade galvanized steel tubing with all fittings fixed to walls, ceilings or laid under floors complete all as specified and as directed.

20

-

-

... More
S&F for ridge or hip tiles to suit Mangalore pattern or roofing tiles, bedded and jointed in lime mortar 1:3 or cement mortar 1:6 complete all as specified and as directed.

30

-

-

... More
All as per Srl item No. 42 here in here in before but as in stirrups.

50

-

-

... More
Supply only integral water proofing compound complete all as specified and as directed.

30

-

-

... More
M&L for POP false ceiling using 600X900X12 mm thick plaster of paris with gypsum binder sheet decorative type and necessary provision for concealed type light fittings, fixed on 22 gauge GI channel grid work, main joist of size 50x25 mm spaced at 750 mm centre, secondary joist of size 75x20 mm fixed to main joists spaced at 900mm, suspended to roof members using 25x25x2 mm GI angles and fasteners @ 1.2M C/C, including dismantling old un serviceable false ceiling complete all as specified and directed.

20

-

-

... More
Supply only micro concrete works in repairs of patches like edges, chajjas, lintels and other RCC members etc complete all as specified and as directed.

1

-

-

... More
Demolition of brick work or stone / boulder masonry built in cement mortar, including all quoins, arches, pillars, etc. complete all as specified and as directed.

5

-

-

... More
S&F for roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) of Fe-410-W(Gde-E-250) quality-B including distance pieces, cleats etc. complete all as specified and directed

500

-

-

... More
S&F 2mm thick fibre glass reinforced translucent corrugated sheeting with two corrugation side lap fixed with L-type or J-type or cranked hook bolts in roofs, walls complete all as specified and as directed.

15

-

-

... More
S&F for rolled mild steel sections of Grade Fe 410-W, (Gde- E-250) quqlity-A, as in post, runners, rafters, purlins, steps etc fixed with connecting plates including bending, welding etc. complete all as specified and as directed.

400

-

-

... More
M&L for PCC 1:2:4 type B0 using 12.5 mm graded stone aggregate, as roof kerbs / padding, using Pidiproof LW+ water proofing chemical of Dr. Fixit or equivalent as per manufacturer's instruction etc. complete all as specified and as directed. Note:-Water Proofing Chemical will be measured and paid separately

90

-

-

... More
S&F 6mm thick asbestos cement two piece adjustable plain wing ridge in roofs complete all as specified and as directed.

10

-

-

... More
All as per Srl item No. 58 here in here in before but in ceiling.

100

-

-

... More
All as per Srl item No 2 here in here in before but 40 mm bore GI Pipe.

20

-

-

... More
All as per Srl item No 11 here in before but exc. 1000 & n exc. 2000 liter capacity.

6

-

-

... More
S&F false ceiling with powder coated exposed GI grid suspension system (E-Grid T-2430 or equivalent load carrying capacity with mid span deflection not exc. 1/360 span with hanger spacing of 1200mm c/c) consisting of main runner 3600mm long, cross Tee 1200mm/600mm long and wall angle. The main runners to be placed @ 1200mm, the cross Tee 1200mm will be inserted in the pre cut slots of main runner at a regular interval of 600mm to form a modular grid of 1200mmX600mm. Additional cross Tees of 600mm shall be placed perpendicular to the cross tee 1200mm long to finally form a grid of 600mmX600mm. Grid of modular size 600mmX600mm shall be supported by 4 mm dia G.I. wire from purlins/soffit with and including 4mm thick high pressure steam cured non asbestos fiber cement designer ceiling board (Density1200Kg/Cum) of size 595mmX595mm, confirming IS 14862 & Type B Category III of ISO 8336, tested as per AS 1530 part 3 & BS-476 Part 4, 5, 6, 7 & 8, complete all as per manufacturer's instruction. (Make : Everest or equivalent as approved by GE)

50

-

-

... More
Taking down cement plaster on brick/concrete surfaces built in cement mortar including raking out joints, bading for key scrubbing down with water etc complete all as specified and as directed.

320

-

-

... More
M&L for rendering 15 mm thick in CM 1:6 on fair faces of brick work or concrete surfaces finishing the surface even and smooth with and including 1 mm thick sagol finish complete all complete all as specified and directed.

100

-

-

... More
M&L for preparation of existing surfaces of roof top, RCC Gutter and parapet wall, crack filling with prime seal chemical and cement @ the ratio of 1:4, applying two coats of water proof chemical (Newcoat of dr. fixit or equivalent) and finally applying a coat of SBR latex and silicon powder paste not less than 2 mm thick complete all as specified and as directed.

110

-

-

... More
M&L for cement concrete tiles 25CmX25CmX22 mm thick, machine pressed,(with grey cement & no pigments), set jointed and pointed in neat cement slurry in floors over and including 15 mm thick bedding layers in CM 1:3 complete all as specified and as directed.

400

-

-

... More
S&F welded steel wire fabric, cut to length, fixed to steel members / reinforcement steel, weigh per Sqm not exc. 4 Kg complete all as specified and as directed.

900

-

-

... More
Material & labour for providing and applying jacketing around columns/beams / other RCC members with Micro concrete (Mokith-MC) including all lifts, shuttering, drilling holes and fixing shear anchor/deficient reinforcement as per manufacturer's specification complete all as specified and as directed. Note : Reinforcement shall be measured and paid separately. (Rates quoted shall be including jacketing, formwork and micro concrete). Make :- Dr. Fixit, STP, Fosroc as approved.

3

-

-

... More
M&L for Preparation of old plastered or unplastered decorated surfaces of wall including cornices, pillasters etc and applying one coat of white wash on walls complete all as specified and as directed.

100

-

-

... More
M&L for Preparation of old painted steel surfaces of any description not otherwise over 10 cm in width or girth and applying one coat of synthetic enamel paint complete all as specified.

30

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Related Tenders

Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.