Military Engineer Services Tender

... More
The MES has issued a formal invitation for competitive bids for the Military Engineer Services project, for Repair And Renovation Of Diat Girinagar Campus Security Peripheral Wall Of Diat, Pune in Pune, Maharashtra, with an estimated contract value of Rs. 28,92,00,000. The bid opening date for this tender is 04-11-2026 and the last date for bid submission is 03-12-2026. Interested bidders for Military Engineer Services tender can download the important documents here to check the scope of work, eligibility criteria and technical requirements.

Military Engineer Services - MES Tender - Maha Tender

Opening Date4 Nov 2026
Closing Date3 Dec 2026
Tender Amount₹ 28,92,00,000 
Notes
Download

Costs

Description

Repair And Renovation Of Diat Girinagar Campus Security Peripheral Wall Of Diat, Pune

Contact

Unlock the Tender details

GEM & Bid Advisory Services

Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
REPAIR AND RENOVATION OF DIAT GIRINAGAR CAMPUS SECURITY PERIPHERAL WALL OF DIAT, PUNE
REPAIR AND RENOVATION OF DIAT GIRINAGAR CAMPUS SECURITY PERIPHERAL WALL OF DIAT, PUNE
REPAIR AND RENOVATION OF DIAT GIRINAGAR CAMPUS SECURITY PERIPHERAL WALL OF DIAT, PUNE
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

Unlock the Tender details
... More
Providing and laying in position ready mixed or site batched design mix cement concrete for plain cement concrete work, all works upto plinth level : concrete of M-10 grade with minimum cement content of 220 kg/cum using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana/Ordinary Portland /PortIand Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering and finishing as per direction of the Engineer-in-Charge; for the following grades of concrete complete all as specified and directed. Note: Extra cement up to10 % of the minimum specified cement content in design mix shall deem to be included in the quoted rate. In case the cement content in design mix is more than 110% of the minimum specified cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.

1338.21

-

-

... More
Coursed rubble masonry (first sort) with hard stone in foundation and plinth with : cement mortar 1:6 (1 cement : 6 coarse sand) complete all as specified and directed.

569.25

-

-

... More
Coursed rubble masonry with hard stone (first or second sort) in superstructure above plinth level and upto floor five level masonry work (first sort), in cement mortar 1:6 (1 cement : 6 coarse sand) complete all as specified and directed.

2549.03

-

-

... More
Pointing on stone work with cement mortar 1:3 (1 cement : 3 fine sand) complete all as specified and directed.

3000

-

-

... More
Providing and fixing up to floor five level precast cement concrete string or lacing courses, copings, bed plates, anchor blocks, plain window sills, shelves, louvers, steps, stair cases, etc., including hoisting and setting in position with cement mortar 1:3 (1 cement : 3 coarse sand), cost of required centering complete 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources: 3 graded stone aggregate 20 mm nominal size derived from natural sources) complete all as specified and directed.

75

-

-

... More
Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm in recharge pit, in the required thickness for all leads & lifts complete all as specified and directed.

2751.38

-

-

... More
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50m and for all lift complete all as specified and directed.

3992.72

-

-

... More
Removal of excavated materials not exceed 50mtr and depositing where directed at a level not exc 1.5m above the starting point complete all as specified and directed.

1286.61

-

-

... More
M&L for supply, laying, spreading and compacting 63 mm to 45 mm size stone aggregate of specified sizes to WBM specifications in uniform thickness, hand picking, rolling with 3 wheeled road / vibratory roller 8-10 tonne capacity in stages to proper grade and camber, applying and brooming requisite type of screening / binding material to fill up interstices of coarse aggregate, watering and compacting to the required density.

2550

-

-

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)

1912.5

-

-

... More
Providing and fixing 1:11/2:3 (1 Cement : 11/2 coarses and (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). at or near ground level precast cement concrete in kerbs, edgings etc. as per approved pattern and setting in position with cement mortar 1:3 (1 Cement : 3 coarse sand), including the cost of required centering, shuttering complete all as specified and directed.

1147.5

-

-

... More
Providing and laying 1 : 1 1/2 : 3 (1 Cement : 1 1/2 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level complete all as specified and directed.

1918.6

-

-

... More
Providing and laying 600 mm dia. R.C.C. pipe non-pressure NP2 class (light duty) R.C.C.pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete all as specified and directed.

22.6

-

-

... More
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 and forall lift complete all as specified and directed.

7.32

-

-

... More
Earthwork in excavation All kinds of soil by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding1.5m in width or 10 sqm on plan),including dressing of sides and ramming of bottoms,for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead of 50 m.

1878

-

-

... More
Providing and laying in position cement concrete of grade 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 40 mm nominal size derived from natural sources) excluding the cost of centering and shuttering- All work up to plinth level complete all as specified and directed.

225

-

-

... More
Brick work with common burnt clay FPS (non modular) bricks of class designation 7.5 in foundation and plinth in cement mortar 1:4 (1 cement : 4 coarse sand) complete all as specified and directed.

517.5

-

-

... More
Providing and laying 1:2:4 (1 Cement:2 coarses and (zone-III) derived from natural sources:4 graded stone aggregate 20mm nominal size derived from natural sources) cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing: complete all as specified and directed.

34.5

-

-

... More
Providing and laying 15 mm cement plaster on rough side of single or half brick wall of mix 1:4 (1 cement: 4 coarse sand) complete all as specified and directed.

1800

-

-

... More
Form work to centering and shuttering including strutting, propping etc. and removal of form for foundations, footings, bases of columns, etc. for mass concrete complete all as specified and directed.

3653.36

-

-

... More
Form work to centering and shuttering including strutting, propping etc. and removal of form for columns, Pillars, Piers, Abutments, Posts and Struts complete all as specified and directed.

12824.779999999999

-

-

... More
Form work to centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers complete all as specified and directed.

8138.55

-

-

... More
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; concrete of M25 grade with minimum cement content of 330 kg/cum . for the All works upto plinth level .using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /PortIand Slag cement, admixtures in recommended proportions as per IS: 9103 toaccelerate/ retard setting of concrete, to improve durability and workability without impairing strength; including pumping ofconcrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the Engineer-in-Charge,

1750.43

-

-

... More
Note: Extra cement up to 10% of the minimum specified cement content in design mix shall deem to be included in the unit rate quoted. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.

-

-

-

... More
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; Concrete of M25 grade with minimum cement content of 330 kg/cum.for the All works above plinth level upto floor V level using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /PortIand Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the Engineer-in-Charge,

1900.64

-

-

... More
Note: Extra cement up to 10% of the minimum specified cement content in design mix shall deem to be included in the unit rate quoted. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.

-

-

-

... More
Steel reinforcement Thermo-Mechanically Treated bars of grade Fe-500D or more for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level complete all as specified and directed.

177056.33

-

-

... More
Steel reinforcement Thermo-Mechanically Treated bars of grade Fe-500D or more for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level complete all as specified and directed.

241269.1

-

-

... More
Providing and fixing up to floor five level precast cement concrete solid block 1:1.5:3 (1 Cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources), including hoisting and setting in position with cement mortar 1:3 (1 cement : 3 coarse sand), including cost of required centering, shuttering complete all as specified and directed.

3558.27

-

-

... More
12 mm cement plaster of mix 1:4 (1 cement: 4 coarse sand) complete all as specified and directed.

27116.510000000002

-

-

... More
15 mm cement plaster on rough side of single or half brick wall of mix 1:4 (1 cement: 4 coarse sand) complete all as specified and directed.

27070.31

-

-

... More
Finishing walls with water proofing cement paint of required shade new work (two or more coats applied @ 3.84 kg/10 sqm) complete all as specified and directed.

54184.31

-

-

... More
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applyinga priming coat of approved steel primer using structural steel etc. as required in gratings, frames, guard bar, ladder, railings, framed brackets (Y horn for the boundary wall), gates and similar works of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, riveting etc., not exceeding 10 kg each brackets, conforming to Fe 290 Gde E-165 complete all as specified and directed.

15270.83

-

-

... More
S&F, galvanised 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacing and straining and fixing to any type of standard rails / post straing bolts, including securing or typing at crossing with and provision of galvanised mild steel wire, staples or steel pins etc (each line of wire to be measured) complete all as specified and directed.

750

-

-

... More
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade. two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture on steel surfaces complete all as specified and directed.

584.76

-

-

... More
Providing and fixing concertina coil fencing with punched tape concertina coil 600mm dia 10m openable length (total length 90m), having 50 Nos rounds per 6m length, upto 3m height of wall with existing angle iron 'Y' shaped placed 2.4m or 3.00m apart and with 5 horizontal RBT reinforced barbed wire, stud tied with GI staples and GI clips to retain horizontal, including necessary bolts or GI barbed wire tied to angle iron, all complete as per direction of Engineer-in-Charge with reinforced barbed tape (RBT) / spring core (2.5mm thick) wire of high tensile strength of 165Kg/sqmm with tape (0.52mm thick) and weight 43.478 gm/metre complete all as specified and directed. Note: The weight of the concertina coil shall be 1.3 Kg/m.

9750

-

-

... More
Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer fixing with 15 x 3mm lugs 10 cm long embedded in cement concrete block 15 x 10 x 10cm of C.C. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete all as specified and directed.

2743.32

-

-

... More
Providing and fixing 25 mm bore G.I. pipes complete with G.I. fittings and clamps, including cutting and making good the walls complete all as specified and directed.

0.6

-

-

... More
Providing and fixing 20 mm bore G.I. pipes complete with G.I. fittings and clamps, including cutting and making good the walls complete all as specified and directed.

24.6

-

-

... More
LED street light fixture 70/72/75 watt, powder coated pressure die cast aluminium body (system lumen efficacy >105 <120 lm/Watt) supplying, installation, testing & commissioning of street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with driver efficiency >85%, input voltage: 140-270 Volt AC, frequency 50/60 hz, operating temp range -5 degree C to 50 degree C, internal surge protection of 5 KV L, N, E as per IEC 61000-4-5, driver efficiency >85%, THD <10% as per IEC 61000-3-2, P.F.>0.95, IP-66, IK-10, CRI>70, under voltage protection, EMIEMC as per CISPR-15, lenses for beam angle as per IESNA type I/II/III as per width of the road and the project requirement, suitable to fit in up to 65mm dia pipe, life time (LED, driver & electrical circuitry) of minimum 50000

300

-

-

... More
burning hours with 70% of initial lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000oK / 4000oK / 5700oK / 6500oK (as per ANSI Bin), SDCM (Standard Deviation Colour Matching) <5, maximum power consumption should not more than the specified rating and fixture shall be of relevant BIS standard complete in all respect including external connections with 1.5 sqmm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing as required with minimum 05 year OEM warranty. System lumen efficacy >105 <120 lm/Watt output. LM79 & LM80 test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90oC).

-

-

-

... More
All as per Sl item No. 41 above but 90 watts.

300

-

-

... More
S&F watch tower search light, high efficiency power LED 02 Nos each 1000W, input voltage AC 220 V, 50-60 Hz IP-65, lamp life not less than 100000 burning hours ,heat resistant toughened glass front cover with silicone rubber gaskets, housed in powder coated cast aluminium body with heat sinks, tripod mounted with beam range over 2000m, nallow beam angle 10 for long distance targeting, min 6000lux at 10m away, 360 degree horizontal rotation and 30 degree vertical tilt operated manually via motorised with a remote control unit complete and all as specified and directed.

8

-

-

... More
S&F, thermoplastic cable junction box of size 205mm x 255mm x 112mm, IP 69, halogen free and weather proof with locking arrangement and necessary mounting arrangement on pole with MS clamp, nut, bolt, washer for outdoor installation complete with connector terminal for connecting cable, knockouts for cable entry up to the size of 25 Sqmm x 4 core, by providing suitable size cable lugs complete all as specified and directed.

300

-

-

... More
S&F, Steel tubular swaged poles ( double arms swan neck / double Shoulder) type (including nut bolt washer) complete with base plate 8mm thick welded with pole, finial taper plug, bolt, nut and screws as specified type 410 SP-31 (9 Mtr long) including one coat of red-oxide zinc chrome primer and two coats of aluminium paint on surfaces exposed to view and making 30cm wide strips with white and black paint alternatively on external surface above PCC benching, numbering with black paint and painting with bituminous paint internally complete and externally for portion embedded in PCC complete all as specified and directed by Engineer-in-Charge.

300

-

-

... More
Note: (i) Design / Drawing / BOM of pole is to be obtained from the Maufacturer / Authorised supplier and the same is to be got approved from Engineer-in-Charge prior to making order to the Manufacturer / Supplier. (ii) Earth work and PCC shall be measured separately.

-

-

-

... More
Excavation in trenches n.exc 1.5 m wide and n.exc 1.5m in depth for erection of poles, laying of cables etc and getting out in hard / dense soil complete all as specified and directed.

250

-

-

... More
Excavation in trenches n.exc 1.5 sqm wide & depth exc 1.5m but n.exc 3m for erection of poles and getting out in hard / dense soil complete all as specified and directed.

177

-

-

... More
Returning, filling in, including spreading levelling, watering and well ramming in layers not exc 25 cm in thick using excavated soil complete all as specified and directed.

377

-

-

... More
Removing excavated material (soil) to a distance n.exc 50 mtrs and depositing where directed at a level n.exc 1.5 mtr above the starting point complete all as specified and directed.

50

-

-

... More
M&L for PCC (1:2:4) type B1, (using 20mm graded stone aggregate) for coping of poles including necessary form work complete all as specified and directed.

28.8

-

-

... More
M&L for providing PCC (1:3:6) type C2, (using 40mm graded stone aggregate) in foundations, filling and mass concrete including necessary form work complete all as specified and directed.

153

-

-

... More
Supply, laying, connecting and testing XLPE cable insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor of size 70 Sq mm 3.5 core (including lugs) in trenches / through GI pipe / fixed along with pole structure with all fixing & connecting accessories complete all as specified and directed.

500

-

-

... More
All as per Sl item No. 52 above but XLPE cable of size 25 Sqmm 4.0 core.

12000

-

-

... More
M&L for DWC pipe heavy duty minimum 63/50 mm dia of required length for protection of cable complete including necessary clamps, nuts, bolts fixed to the wall and ceilling or laid in floors complete all as specified and directed.

10000

-

-

... More
M&L for GI pipe light grade with all fixtures and fittings (ISI Marked), laid in trenches, under road or fixing on wall / pole / crossing drain / nallah etc. of bore 50 mm complete all as specified and directed. Note: Wherever GI protection pipes are to be placed / fitted above earths surface, cost of necessary clamping / fixing arrangements to the entire satisfaction of Engineer-in-Charge is deemed to be included in the unit rate quoted.

400

-

-

... More
M&L for cutting the existing hardstanding / PCC/WBM road at a depth of not less than 60 cm & 30 cm in width for passing of HT cables through GI pipes, returning filling in, complete incl finishing the surfaces by providing cement concrete type B1 (1:2:4) with 20 mm graded aggregate upto 20 cm, finishing to a uniform smooth surface complete all as specified and directed.

200

-

-

... More
Note for Sl item No. 46, 47 & 56: Any damages made to the existing services of MES/WCB/Other Depts like HT/LT UG cables, Water Supply / Sewage pipe lines, OFC/BSNL/Signal communication cables etc. during the excavation / road cuting, progress of the work shall be made good with proper jointing kits etc. as per original to the entire satisfaction of Engineer-in-Charge & GE, the cost of the same is deemed to be included in the unit quoted rates. Decision of the AO shall be final & binding.

-

-

-

... More
M&L for earthing complete with galvanized steel earth plate electrode 600 x 600 x 6.0mm thick buried directly in ground (in vertical position) earth pit not less than 2.25 mtr below normal ground level with the top edge of the earth plate not less than 1.5 mtr (B.G.L.) and connected to galvanized earth lead wire 4.0mm dia by means of bolts, nuts, check nuts, and washers of galvanized iron including PCC pit & cover with suitable handle, including necessary excavation and earth work in any type of soil, 20mm dia medium grade galvanized steel tube for watering with one end fixed with suitable funnel and wire mesh, 25mm bore medium grade galvanized steel tubing for drawing earth lead GI strip protection & common salt, charcoal in alternate layers etc. complete all as shown on FIG F-18 (Clause F-8.9.2(c)) Method of Plate Earthing [Clause 8.4.1.1(ii)] & arrangement as per Fig F-3 (Clause F-3) Earthing of Generator and mains incoming with changeover – reproduction of figure 38 from IS3043:2018 of CPWD specification electrical and mechanical and testing on completion including taking down old unserviceable earthing complete.

30

-

-

... More
M&L for earthing complete with galvanized steel earth plate electrode 600 x 600 x 6.3 mm thick buried directly in ground (in vertical position) earth pit not less than 2.25 mtr below normal ground level with the top edge of the earth plate not less than 1.5 mtr (B.G.L.) and connected to galvanized iron earth strip 32 x 6 mm by means of bolts, nuts, check nuts, and washers of galvanized iron including PCC pit & cover with suitable handle, including necessary excavation and earth work in any type of soil, 20mm dia medium grade galvanized steel tube for watering with one end fixed with suitable funnel and wire mesh, 40mm bore medium grade galvanized steel tubing for drawing earth lead GI strip protection & common salt, charcoal in alternate layers etc. complete all as shown on FIG F-18 (Clause F-8.9.2(c)) Method of Plate Earthing [Clause 8.4.1.1(ii)] & arrangement as per Fig F-3 (Clause F-3) Earthing of Generator and mains incoming with changeover – reproduction of figure 38 from IS3043:2018 of CPWD specification electrical and mechanical and testing on completion including taking down old unserviceable earthing complete.

12

-

-

... More
Supply, install, testing & commissioning of LT control panel board "out-door type" of size 1200 mm (height) x 1200 mm (breadth) x 500 mm (depth) (minimum dimensions), factory fabricated CPRI approved (type-tested) with suitable neoprene rubber gasket to make it completely dust & vermin proof & degree of protection not less than IP-55 & general construction confirming to IS-13947, double door, front & back openable. The panel shall be provided with ventilation facility in the form of louvers for better heat dissipation & high grade aluminum bus-bar wrapped with coloured PVC tape / sleeves of rating in conformity to the Incoming ACB/MCCB rating. The panel board shall be fabricated out of 3.15mm thick (for outer portions) & 2.00mm thick (for inner portions) CRCA sheet duly pre-treated & powder coated, supporting angle iron frame & MC channel base suitable for 3 Phase, 4 wire system 415/440 volts grade including complete

3

-

-

... More
internal wiring with not less than 2.5 Sqmm copper wire including cable glands of suitable sizes with suitable PCC (1:3:6) type C2 foundation, necessary earthwork (if any) including taking down old unserviceable LT panel of any size/type complete all as specified and directed with & including the following accessories :- [ Distribution Panel] BUS-BAR & INTERNAL CONNECTIONS: The bus-bars shall be made up of 04 Nos high grade aluminium 200 A rated, duly insulated with 1100 V grade standard colour coded PVC sleeves & rigidly mounted on suitable sized "F" class insulators of non-hygroscopic, non-combustible, all internal connections from main bus-bars to switch gears etc.

-

-

-

... More
PROVISION FOR CABLE ENTRY: The provision for cable entry/exit shall be provided in the bottom for both incoming & out-going cables with the help of glands matching the existing LT cable sizes. INCOMING: (a) MCCB 4P (Ics = 100% Icu) with thermal magnetic release, adjustable short circuit & adjustable overload setting, suitable for isolation, having breaking capacity 36 KA & of rating 100 to 125 A - 01 No. OUTGOINGS: (a) MCCB 4P (Ics = 100% Icu) with thermal magnetic release, adjustable short circuit & adjustable overload setting, suitable for isolation, having breaking capacity 25 KA & of rating 80 to 100 A - 02 Nos (1W +1S).

-

-

-

... More
(b) MCCB 4P (Ics = 100% Icu) with thermal magnetic release, adjustable short circuit & adjustable overload setting, suitable for isolation, having breaking capacity 25 KA & of rating 63 to 80 A - 01 No. (c) Time switch 415 Volts, 3 Phase of 20 Amps rating with contactor complete. (d) MCB SPN "C" series having breaking capacity 10 KA of rating 40 Amps - 02 Nos. (e) MCB TPN "C" series having breaking capacity 10 KA of rating 06 to 32 Amps - 01 No. INSTRUMENTATION SYSTEM: (a) Digital type multi-function meter with built in selector switch & 03 Nos CTs matching with the I/C breaker, Accuracy Class - 1.0, 3 phase, size 96 x 96mm.

-

-

-

... More
(b) Indicator lamp with integral circuit (230/240V) & cluster LED (Red, Orange, Blue) - 01 Set. (c) Danger notice plate of size 20 x 15 cm of 1.6mm thick mild-steel sheet, vitreous enamelled white, with letters, figures and conventioinal skul and bones in signal-red colour and fixed with MS clamps, bolts and nuts of approved size, for LT conforming to IS-2551 - 02 Nos (Front & Back). (d) Door opening key - 02 Nos. Note: i) Design / drawing / BOM of the Panel Board showing the dimensions alongwith CPRI type-test Cert is to be obtained from the Manufacturer / Supplier & is to be got approved from the Engineer-in-Charge & GE before placing final order to the manufacturer.

-

-

-

... More
ii) Any details missed out in the technical specifications but technically required for efficient working is deemed to be included in the quoted rates. iii) The cost of taking down old unserviceable LT Panel boards of any size / type from existing location & keeping in safe custody for re-use or for taking Schedule of Credit including making good the disturbed surfaces is deemed to be included in the unit quoted rates.

-

-

-

... More
Supply, installation, commissioning & testing of silent built in within an acoustic enclosure diesel engine driven generating set water cooled including customized AMF panel for standby power supply 415 volts, 03 Phase, 4 wire, 50 cycles/sec, 35 KVA at 0.8 power factor perfectly suitable for outdoor mounting (open to air) at an altitude of 1900.0 Mtr above MSL (Mean Sea Level) & suitable for starting at a temperature of - 3 degree C complete with alternator directly coupled to diesel engine, mounted on common base frame & complete with self starter, fuel tank capacity not less than 08 hours fuel requirement & battery as per OEM, battery leads, sound proof canopy, cold starting kit (L3 Kit in case of KOEL) or techno-commercially equivalent etc. & confirming to latest CPCB -IV+ norms

3

-

-

... More
with features for automatic shutdown in the event of a circuit failure condition arising from low lube oil pressure, high engine temperature, over/under speed etc. with & including microprocessor based genset controller with the following undermentioned features complete all as specified and directed: - a) Graphical LCD display. b) Operator interface. c) Suitable to provide a record of most recent fault conditions & fault history. d) Complete alternator data viz, voltage ph - ph, ph - neutral, current, KVA, KW, frequency, PF etc.

-

-

-

... More
e) Complete engine data viz, starting battery voltage, engine temp, engine runnning hours, engine oil pressure etc. f) Battery charging condition, fuel usage, AMF feature etc. g) Control including provision of service adjustment & calibration of DG control functions. GENSET SPECIFICATIONS: NO OF PHASES : 03 POWER FACTOR : 0.8 (LAG) FREQUENCY : 50 HZ VOLTAGE : 415 V, 3 PH ENGINE SPECIFICATIONS: PRIME MOVER RATING: 35 KVA ASPIRATION : TA NO OF CYLINDERS : multi RPM : 1500

-

-

-

... More
ALTERNATOR SPECIFICATIONS: IP PROTECTION : IP 23 INSULATION CLASS : H CLASS CONFORMANCE STANDARDS: IS 4722, IS 1460, ISO 8528, ISO 3046, IS 13018, IS/IEC 60034-1, IS 10002, BS 5514, CPCB -IV +/Latest etc. Make, size & No of Battery: As per OEM. AMF PANEL SPECIFICATIONS (outdoor type): MSEB I/C: MCCB 4P (Ics = 100% Icu) with thermal magnetic release, adjustable short circuit & adjustable overload setting, suitable for isolation, having breaking capacity 25 KA & of rating 63 to 80 A - 01 No. DG I/C: MCCB 4P (Ics = 100% Icu) with thermal magnetic release, adjustable short circuit & adjustable overload setting, suitable for isolation, having breaking capacity 25 KA & of rating 63 to 80 A - 01 No.

-

-

-

... More
AMF MAIN O/G: MCCB 4P (Ics = 100% Icu) with thermal magnetic release, adjustable short circuit & adjustable overload setting, suitable for isolation, having breaking capacity 25 KA & of rating 63 to 80 A - 01 No. The size / rating of all the connected accessories viz. contactors, relays, timers, bus-bars, connecting cables etc. of the AMF panel shall be as per OEM & in conformity with the I/C & O/G MCCBs duly provided with bypass system / arrangement complete. IMPORTANT NOTES: i) Design/drawing/BOM of the AMF panel & DG SET showing the dimensions is to be obtained from DG set / Panel board manufacturer / Auth supplier & is to be got approved from Engineer-in-Charge & GE before placing final order to the manufacturer.

-

-

-

... More
ii) The electrical connection of digital Multi Functional Meter in the AMF panel is to be done from load side so that monitoring of various parameters viz. Voltage, Current, KW, KVA, power factor, frequency etc. can be done for both SEB mains & DG mains. iii) The cost of periodical/routine servicing including minor repairs/replacement such as topping up of coolant, engine/lube oil, diesel as well as lube-oil filters including periodical checking of the complete DG set & AMF panel for the complete defect liability period from the authorized Service Dealer as & when required/due is deemed to be included in the unit quoted rates. iv) The complete installation, commissioning & testing of the DG set & AMF panel is to be got done from the OEM or their auth Rep / Sister Concern / Channel Partners only.

-

-

-

... More
v) Any details missed out in the technical specifications but technically required for efficient working of the DG set & AMF panel is deemed to be included in the quoted rates. vi) Necessary PCC foundation/plinth shall be as per the recommendations of OEM & cost of the same is deemed to be included in the quoted rates. vii) The quoted rate shall be deemed to be inclusive of factory testing and 12 Hrs test run at site as specified in the PS in presence of rep of Accepting Officer, all testing arrangements / equipments, resistive load including POL shall be made available by the contractor.

-

-

-

... More
viii) The approximate distance between the DG set & the AMF panel shall be within 20 Mtrs & the cost of control cabling from DG set to the AMF panel is deemed to be included in the unit quoted rates. ix) The DG set & AMF panel shall be completely suitable for switching ON the DG set whenever EB supply goes OFF & transfer the load to DG & vice-versa in the event of resumption of EB supply.

-

-

-

... More
M&L for earthing complete with copper earth plate electrode 600 x 600 x 3.15mm thick buried directly in ground (in vertical position) earth pit not less than 2.25 mtr below normal ground level with the top edge of the earth plate not less than 1.5 mtr (B.G.L.) and connected to copper earth strip 20 x 3mm by means of bolts, nuts, check nuts, and washers of galvanized iron including PCC pit & cover with suitable handle, including necessary excavation and earth work in any type of soil, 20mm dia med grade galvanized steel tube for watering with one end fixed with suitable funnel and wire mesh, 40 mm bore medium grade galvanized steel tubing for drawing earth lead GI strip protection & common salt, charcoal in alternate layers etc. complete all as shown on FIG F-18 (Clause F-8.9.2(c)) Method of Plate Earthing [Clause 8.4.1.1(ii)] & arrangement as per Fig F-3 (Clause F-3) Earthing of Generator and mains incoming with changeover – reproduction of figure 38 from IS3043:2018 of CPWD specification electrical and mechanicaland testing on completion including taking down old unserviceable earthing complete.

6

-

-

... More
S&F, 20 x 3 mm copper strip as earth continuity conductor including connection complete with the help of chromium plated washers, nuts etc. to Generator Body / Neutral, AMF/DG O/G panel body complete all as specified and directed.

30

-

-

... More
S&F, 32 x 6 mm galvanised iron strip as earth continuity conductor including connection complete with the help of chromium plated washers, nuts complete all as specified and directed.

40

-

-



Evaluation Notes How It Works ?

Related Tenders

Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.