Military Engineer Services Tender

... More
The MES has issued a formal invitation for competitive bids for the Military Engineer Services project, for Provision Of Defi Officers Md Accn (ph-ii Of Two Phases) Under Ge (c) Pune in Pune, Maharashtra, with an estimated contract value of Rs. 32,00,00,000. The bid opening date for this tender is 22-10-2026 and the last date for bid submission is 28-11-2026. Interested bidders for Military Engineer Services tender can download the important documents here to check the scope of work, eligibility criteria and technical requirements.

Military Engineer Services - MES Tender - Maha Tender

Opening Date22 Oct 2026
Closing Date28 Nov 2026
Tender Amount₹ 32,00,00,000 
Notes
Download

Costs

Description

Provision Of Defi Officers Md Accn (ph-ii Of Two Phases) Under Ge (c) Pune

AI Insights

Unlock AI Insights for this Tender

Sign in to request AI-powered insights, eligibility criteria and automated analysis for this tender.

Contact

Unlock the Tender details

GEM & Bid Advisory Services

Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

Unlock the Tender details
... More
Total amount of Sch 'A' Part-III (Internal Water Supply)

1

1757313

-

... More
Total amount of Sch 'A' Part-IV (Internal Electric Supply)

1

10443892

-

... More
Total amount of Sch 'A' Part-V (Road, Paths & Culverts )

1

5253604

-

... More
Total amount of Sch 'A' Part-VI (Sewage Disposal)

1

819021

-

... More
Total amount of Sch 'A' Part-VII (Area Drainage)

1

2084501

-

... More
Total amount of Sch 'A' Part-VIII (Fire Fighting)

1

1949653

-

... More
Total amount of Sch 'A' Part-IX (Lightning Protection)

1

504608

-

... More
Total amount of Sch 'A' Part-X (External Water Supply)

1

505187

-

... More
Total amount of Sch 'A' Part-XI (External Electric Supply)

1

3903836

-

... More
Total amount of Sch 'A' Part-XII (Rain Water Harvesting)

1

1113932

-

... More
SCHEDULE 'A' PART-XIII (MISCELLANEOUS B/R AND E/M WORKS)

-

-

-

... More
INTERNAL WATER SUPPLY

-

-

-

... More
S & F Pillar Cock with aerator 16 mm dia. Make- Cera- Victor F1015101 or equivalent in Jaquar, Kohler brand complete all as specified and directed by Engineer-in-Charge (Flow of the fixture must be 3.0 litre per minute or less)

204

-

-

... More
S & F Bib cock with wall flange and aerator, 16 mm dia. Make - Cera-Victor- F1015151 or equivalent in Jaquar, Kohler brand complete all as specified and directed by Engineer-in-Charge (Flow of the fixture must be 3.0 litre per minute or less)

280

-

-

... More
S & F Two way bib cock with side handle, wall flange and aerator 16 mm dia. Make -Cera- Titanium Model No F1003161 or equivalent in Jaquar, Kohler brand complete all as specified and directed by Engineer-in-Charge. (Flow of the fixture must be 3.0 litre per minute or less)

164

-

-

... More
S & F Hand shower (Health faucet) with 1 meter long easy flex tube in chrome finish and wall hook with NRV (Back flow preventer) Make - Cera - F8030104AB or equivalent in Jaquar, Kohler brand complete all as specified and directed by Engineer- in-Charge

164

-

-

... More
S & F Angular Stop Cock 15 mm bore of pipe (16 mm outer dia) with Wall Flange chromium plated Stop valves. Make Cera - F8040204 or equivalent complete all as specified and directed.

768

-

-

... More
S & F Overhead rain shower square, with Shower Arm 180mm with wall flange. Make: Cera - F7010501AB and Cera- F7040101 or equivalent in Jaquar, Kohler brand complete all as specified and directed by Engineer-in-Charge (Flow of the fixture must be 3.0 litre per minute or less

120

-

-

... More
S & F Wall mixer with bend pipe for overhead shower. Make Cera - F1015401 or equivalent in Jaquar, Kohler brand complete all as specified and directed. (Flow of the fixture must be 3.0 litre per minute or less)

120

-

-

... More
INTERNAL ELECTRIC SUPPLY

-

-

-

... More
S & F vertical triple pole and neutral DB, double door, metallic modular distribution board for conforming to IEC 61439-3, suitable for flush / surface mounting with provision for MCCB up to 160 A as incomer and SP/TP MCBs as outgoing, reversible metal door, fully insulated 250 A copper busbar for each phase, two fully insulated & shrouded neutral bars, two earthbars, cable ties for cable management, Prefitted masking sheet, etc. complete all as specified and directed by engineer-in-charge. vertical triple pole & neutral double door DB, 6 way NOTES: [i] FP RCCB / RCBO / Isolator / MCB & SP/TP MCBs shall be measured and paid separately.

2

-

-

... More
S & F moulded case circuit breaker (MCCB), four pole, in single frame size up to 250 A with thermal magnetic trip unit (TMD), compression lug connectors, protection against overloads (Ir adjustable from 0.7- 1 X In), protection against short circuits (Isd adjustable from 1.5- 10 X Ir),earth fault leakage protection, etc. having Ics = 100% Icu as per IEC 60947-2 complete all as specified and directed by engineer-in-charge. 125 A, 415 V, 10 kA, 50 Hz FP MCCB

2

-

-

... More
Supply, installation, testing and commissioning of factory made, CPRI type tested, indoor cubical compartmental type Metering Panel of suitable size, conforming to IEC 61439-1 & 2 and IEC 61641, having both sides openable with hinged single doors and locking arrangement, IP 43 protection made out of 2.0 mm thick mild steel CRCA sheet, supported and fixed on structural frame of angle iron of suitable size, including earthing stud, labelling, painting to all internal & external exposed steel surfaces with powder coating paint (7 tank process), duly fixed in ground with PCC foundation (1:2:4) type B1, with danger notice plate of 1.6 mm thick mild steel vitreous enamelled (white) with letters, figures and conventional skull and bones in signal red colour suitable for 3- Phase, 4 Wire system, 500 V grade with necessary wiring, PVC sheathed stranded copper conductor of appropriate length and size, including fixing lugs, bolts, screws, etc. complete all as specified and directed by engineer-in-charge. The metering panel shall comprise of the following:

4

-

-

... More
Busbar Chamber: [i] 01 Set (3L + N) of copper busbar of rated capacity 200 A, minimum current density 1.3 Amp / Sq. mm, covered with PVC insulated sleeves including insulator, nuts, bolts, etc. with complete connection Incoming: [i] 160 A, 415 V, Ics = 100%Icu, 25 kA, conforming to IS/IEC 60947-2, 50 Hz, 4P MCCB with microprocessor based release, overload protection with inverse time delay, instantaneous protection with fine settings, protection against current unbalance and single phasing, inbuilt earth fault and neutral overload protection, compression lug connectors [ii] Cl 1.0 multi-function meter capable of measuring V, A, F, PF, W/VA, Wh/VAh, Runhrs. Onhrs & interrupts- 01 Nos. [iii] LED phase indicators (Red, Yellow, Blue)- 01 Set Outgoing: [i] 32 A, 415 V, 10 kA, 50 Hz, FP MCB - 10 Nos. (for typical D.U) [ii] Space for three phase energy meter. - 10 Nos.( which is measured at relevant item [iii] LED phase indicators (Red, Yellow, Blue)- 10 Set [iv] Cl 1.0 multi-function meter capable of measuring V, A, F, PF, W/VA, Wh/VAh, Runhrs. Onhrs & interrupts-10 Nos.

-

-

-

... More
S & F 20 W, 230V surface / wall mounted, 4 feet LED batten capable of delivering 2000 lumen, having PC diffuser, luminous efficacy of > 90 lumen/W, CRI > 80, PF > 0.9, CCT 6500K, polycarbonate diffuser, housed in powder coated white extruded aluminium channel housing. white coloured ABS end caps, IP 20 protection, input frequency 50 Hz, including electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the fixture complete all as specified and directed by the engineer-in-charge.

772

-

-

... More
S & F 10 W, 230V surface / wall mounted, 2 feet LED batten capable of delivering 1000 lumen, having PC diffuser, luminous efficacy of > 90 lumen/W, CRI > 80, PF > 0.9, CCT 6500K, polycarbonate diffuser, housed in powder coated white extruded aluminium channel housing. white coloured ABS end caps, IP 20 protection, input frequency 50Hz, including electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the fixture complete all as specified and directed by the engineer-in-charge.

604

-

-

... More
S & F 10 W LED, 1 feet Mirror light suitable for wall mounting & 230 V, 50 Hz mains voltage with built-in LED & driver, luminous efficacy of > 90, power rating ≤ 8 W, including IP 20 protection as well as electrical connection with 3 core 1.0 mm² PVC insulated copper conductor unarmoured cable to the fixture complete all as specified and directed by engineer-in-charge.

160

-

-

... More
S & F 12 W , 230V surface mounted round shape, 7 inch LED downlight capable of delivering 1200 lumen. having minimum luminous efficiency > 100 lumen/W, CCT 6500K, CRI > 80, high quality polycarbonate diffuser, input frequency 50- 60 Hz, including electrical connection complete all as specified and directed by the engineer-in-charge.

92

-

-

... More
S & F 10 W , 230V surface mounted bulkhead LED capable of delivering 700 lumen. having minimum luminous efficiency > 107 lumen/W, CCT 6500K, CRI > 80, high quality polycarbonate diffuser, input frequency 50 Hz, including electrical connection complete all as specified and directed by the engineer-in-charge.

24

-

-

... More
S & F 25 W street light having high efficiency long life LED module with SMD LED package mounted on MCPCB with high LED efficacy of ≥ 2600 lumen/W, having minimum luminous efficiency > 100 lumen/W, integral SMPS based constant current electronic LED driver with THD < 20%, surge voltage protection and other safety tests as per IS: 15885 (Part-2/Sec-13): 2012, IP 66 protection, high efficacy polycarbonate cover with integrated lens housed in pressure die-cast aluminium alloy heat sink for effective thermal management, sturdiness, excellent corrosion resistance, separate optical and control gear compartment & top opening for easy maintenance, suitable for side entry, pole mounting with bracket arm OD 35 mm to 42 mm including necessary electrical connection to the fixture with 3 core flexible Cu conductor cable of appropriate size and 1.5 m long bracket, having 40 mm diameter light grade GI pipe, including GI clamps, nuts, bolts & washers with two coats of synthetic enamel paint over a coat of red oxide primer complete in all respect as specified and directed by engineer-in-charge.

30

-

-

... More
Supply and fix termination Geyser/AC box including 20A MCB C curve 10KA with plug and socket complete all as specified and directed

160

-

-

... More
S& F VTPN DB 6 way (Vertical type) , double door, metallic distribution board, conforming to IEC 61439-3, suitable for flush I surface mounting with provision for FP RCCB I RCBO IMCCB as incomer and SPITPN MCBs as outgoing, reversible metal door, 100 A copper bus bar, fully shrouded neutral bar, earth bar, wire set& cable ties for cable management, pre fitted masking sheet, etc. having IK 09 & IP 43 protection complete all as specified and directed.

2

-

-

... More
S & F SPN DB with sheet metal enclosure 240 volts, 6 way, Single phase, double door with copper bus bar neutral link, Each earth link, earthing studs, without MCBs complete all as specified and directed.

9

-

-

... More
S & F MCCB 125 Amp, 415V, 4 pole, 25 KA complete all as specified and directed.

2

-

-

... More
M & L for Submain wiring alongwith earth wire of size 4x6.0 sq. mm + 2x6.0 sq. mm earth wire lSI marked FRLSH PVC insulated multi stranded copper conductor, single core cable drawn in and including PVC concealed conduit lSI marked, medium grade of adequate size with all conduit accessories medium grade lSI marked as required as specified and directed. Note :- (i) Four run of PVC wire and Two run of earth wire, 1 run of conduit will be measured as one length

50

-

-

... More
M & L for Submain wiring alongwith earth wire of size 4 x10.0 sq. mm + 2x10.0 sq. mm earth wire lSI marked FRLSH PVC insulated multi stranded copper conductor, single core cable drawn in and including PVC concealed conduit lSI marked, medium grade of adequate size with all conduit accessories medium grade lSI marked as required as specified and directed. Note:- (i) Four run of PVC wire and Two run of earth wire, 1 run of conduit will be measured as one length

1100

-

-

... More
Supply, installation, testing and commissioning as per IS IIEC-61439-1 &2, Main L T cum Metering Panel, indoor type CPRI Each Approved IP-43 protection of suitable size to accomodate the following accessories with comprising of the following and complete all as specified and directed. Fabrication Details : main·frame 2 mm thick CRCA sheet, partition sheets I covers I doors of 1.6 mm thick CRCA sheet, gland plates 1.6 mm thick MS sheet (undrilled), base frame of 75 mm MS channel thprovision of incoming and outgoing cable entry at the bottom for installation, seperate chambers for Main Bus Bars, switch Gears and Cable end connections free standing floor mounted with degree of protection /P 54 and with heavy duty Hinges for doors and locking arrangements with A/drops at front and Back complete all as specified and directed. Bus bar details : Material shall be Aluminium bus bar 250 Amp rated, 25kA, 3L +N, sleeving heat shrinkable type, with bus bar sizes for phase of rated capacity and bus bar shall extended type be support of epoxy type insulators for connection ,earthing of 40x6 mm Gl Flat complete all as specified and directed. Painting Detais : Painting shall be 7 tank processed powder coated/ epoxy coated shall be a dry finishing process that uses finely ground particles of pigment and resin based polymer that are electrostatically charged and sprayed onto electrically grounded parts complete all as specified and directed.

4

-

-

... More
Wiring: Pannel wiring shall be of 2.5 sq mm copper standard with 5A MCB wiring for con troll wiring and indication lamps complete all as specified and directed. INCOMING: (i) MCCB 4P of capacity 160 Amps, 415 Volts, 50 Hz, 3 phase breaking capacity 25 KA with thermal magnetic release & /cs=1 00% leu -01 No~ (ii) Digital type AC ameter 0-200 A, 03 No.CTs(Type: CBF-.6-D1 accuracy class-1),3 phase accuracy class 1-01 No (iii) Digital type AC voltmeter: 3 phase ,30- 600 volt range ,accuracy class- .5- 01 No (iv) Modular indicator lamp with integral circuit (2301240 volt) and cluster LED (RED, ORANGE, BLUE) -01 set OUTGOING (a) MCCB 4P of capacity 40 Amps, 415 Volts, 50 Hz, 3 phase breaking capacity 25 KA with thermal magnetic release & lcs=100% leu -12 Nos (01 x Spare) (b) MCB SPN o( capacity 20 Amps, 230 Volts, 50 Hz, Single phase breaking capacity 10 KA, 'C' curve fixed on Din rail-11 Nos. (01 x Spare) (c) Provn for Fixing Smart Meter 3 phase, 10 -60 Amps - 1 0 Nos (smart Meter measured seperately) · (d) Bus Bar Aluminium TPN 40 Amps rating ,4 Nos, 0.15 Mtr -10 Nos (d) Danger notice plate of size25 x 20 em of 1 .6 mm thick mild steel sheet, vitreous enameled white, with letters, figures and conventional skull and bones in signal-red colorand fixed with MS clamp and bolt and nuts of approved size fos L T conforming to /S:2551 complete-02 nos

-

-

-

... More
S&F SPN DB with sheet metal enclosure 240 volts, 4 way, Single phase, double door with copper bus bar neutral link, Each earth link, earthing studs, withoui MCBs complete all as specified and directed.

2

-

-

... More
Supply, installation, testing and commissioning of LED Aviation Obstruction Light for rnultistoried building, Red in colour, 10 Watt, low intensity, 230 Volt AC, 50 Hz, single Phase, Heavy duty die-cast aluminium baby, weather proof, IP 65, clear UV resistance polycarbonate dome, corrosion resistance aviation yellow finish body, complete with all accessories and mounting bracket/base SS hardware, cable gland, earth terminal all as specified and as directed.

2

-

-

... More
Road, Paths & Culverts

-

-

-

... More
M & L for preparing bituminous surfaces of road and marking 2.5mm thick centre lines, stop lines, dashes, arrows etc. and the like on roads pavements with hot applied thermo plastic road marking paint of approved colour confirming to BS 3262-1989 with special applicator machine all as per manufacturers instruction complete all as specified and directed.

81

-

-

... More
Fire Protection System

-

-

-

... More
Supply, installation, testing and commissioning of FM approved or UL listed remote power supply conforming to UL 864 & 1481 and NFPA 72 with integral battery charger capable of charging up to 18 Ah batteries to provide regulated and filtered 24 VDC power to notification appliance circuits, having power-supervision relay, fully regulated and filtered power output, AC trouble report selectable for immediate 2-hour delay, selectable earth fault detection, etc. complete all as specified and directed by engineer-in-charge. Make: Notifier HPF24S6E or equivalent model of JC, Esser

2

-

-

... More
M & L for low smoke zero halogen (LS0H) flame retardant fire alarm cable, conforming to BS 7629-1, BS 6387 & BS EN 50200 and rated for 500 V, having plain annealed stranded copper conductor with primary insulation of glass mica fire resistant tape and secondary insulation of high performance silicone rubber, earth/drain wire of annealed tinned copper, electrostatic screen of aluminium fire barrier and type LTS3 outer sheath conforming to BS 7655, suitable for operating temperature range -30 ˚C to +70 ˚C and minimum bending radius being 6 times the overall cable diameter, RED in colour, including laying, termination and ferruling complete all as specified and directed by engineer-in-charge. Make: RR Kabel, Polycab, Havells

180

-

-

... More
M & L for transparent FR PVC insulated, twin core copper conductor flexible industrial Speaker cable having stranded annealed tinned copper conductor, PVC insulated cores twisted to form pairs, shielded for interference rejection, unarmoured PVC sheathed 1.1 kV grade in conductor size 2 X 1.0 mm2 including laying, termination and ferruling complete all as specified and directed by engineer-in-charge. Make: RR Kabel, Polycab, Havells

250

-

-

... More
Supply, installation, testing and commissioning of UL listed (fire fighter's) addressable Telephone Jack mounted to a single-gang electrical back box with suitable interface module for two way communication with the Central Fire Fighter Telephone Console complete all as specified and directed by engineer-in-charge. Make: Notifier FPJ + FCM-1 or equivalent model of JC, Esser

12

-

-

... More
Supply, installation, testing and commissioning of UL listed Fire Fighter's Telephone Handset for two way communication with the Central Fire Fighter Telephone Console complete all as specified and directed by engineer-in-charge. Make: Notifier FHS or equivalent model of JC, Esser

2

-

-

... More
Supply, installation, testing and commissioning of UL listed all purpose 2 W ceiling speaker having crush and rust resistant design and fully ABS plastic & ABS grille with tap-setting range between 1/4 W and 2 W, rated (RMS) voltage 70.7 V, sound pressure level at 1 W (1 m & 1 kHz) 80 ± 4 dB, frequency response 125 Hz- 16 kHz, (-10 dB with reference to 1 kHz), complete all as specified and directed by engineer-in-charge. Make: Notifier NF-SP100CI/UL or equivalent model of JC, Esser

52

-

-

... More
Supply, installation, testing and commissioning of UL listed Digital Audio Amplifier capable of accessing and processing one of up to eight audio channels on the DVC audio loop, amplifying the signal and distributing it via eight Class B (speaker line) outputs having two wire digital audio ports to connect to wire DAL (digital audio loop) segments, Firefighter telephone riser supporting 7 active firefighter telephones, 300 W total output at 70 V (RMS) complete all as specified and directed by engineer-in-charge. Make: Notifier DS-DB + DS-AMPE or equivalent of JC, Esser

2

-

-

... More
M & L for 1.1 kV grade copper conductor, XLPE insulated armoured cable conforming to IS 7098 (Part 1): 1988, having stranded aluminium compact shaped conductors as per Cl. 2 of IS 8130: 1984, PVC inner sheath, single armouring of galvanised steel strip/wire and PVC Type ST-2 outer sheath conforming to IS 5831: 1984, including necessary clamping / dressing with cable ties and termination complete all as specified and directed by engineer-in-charge. Make: Polycab, Havells, Finolex 4 core 10 sqmm

50

-

-

... More
Supply, installation, testing, and commissioning of Fully automatic Star-Delta starter, suitable for the booster pump, complete with contactors, push button, LED type indicators, auto/manual selector switch, overload protection, current sensing type single phase preventer complete with all accessories and wiring etc. With complete all as specified and directed by the engineer-in-charge.

2

-

-

... More
S & F of PN 1.6 rated 25 mm NB full bore, two piece design, quarter turn, lever operated brass ball valve having nickel-plated forged brass body & end connector, brass chrome plated ball, PTFE body seat ring & packing, H.T. brass stem, nut & gland, rubber 'O' ring, powder coated MS lever and screwed female ends, etc. with accessories complete as specified and directed by the engineer-in-charge. Make: Leader, Sant, Venus

12

-

-

... More
S & F of orifice plate made out of 6 mm thick SS 304 with orifice of required size to be fitted between flange and landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as specified and directed by the engineer-in-charge. Make: Newage, AAAG, Minimax

16

-

-

... More
M & L for FM approved and UL listed 25 mm NB compact 3 position ball valve with drain orifice (test and drain valve) to test and drain water flow through sprinkler systems having OFF-TEST-DRAIN position, integral sight glass, rated pressure 300 psi, orifice size 15 mm and K factor 5.6, conforming to NFPA 13, along with necessary accessories complete as specified and directed by the engineer-in-charge. Make: Tyco, HD, Viking

2

-

-

... More
M & L for low smoke zero halogen (LS0H) fire survival control cable with circuit integrity, conforming to BS 7846 and rated for 600 V, having plain annealed stranded copper conductor with fire-resistant mica tapes covered by an extruded layer of cross-linked polyethylene, extruded layer of thermoplastic low smoke zero halogen (LS0H) compound, single layer of galvanized steel wires and thermoplastic LS0H compound sheath, suitable for operating temperature range -40 ˚C to +90 ˚C and minimum bending radius being 12 times the overall cable diameter, including laying, clamping, termination and ferruling complete as specified and directed by the engineer-in-charge. Make: Polycab, Havells, Finolex 2 core, 1.5 mm² (for instrumentation)

50

-

-

... More
S & F 9 kg capacity dry chemical powder (ABC) type fire extinguisher, conforming to IS 15683: 2006, with initial filling in brand new cylinder with powder coated finish, fitted in gunmetal union, high pressure CO2 gas cartridge, discharge hose, wall mounting bracket / floor trolley mounting accessories along with suitable signage, etc. complete all as specified and directed by the engineer-in-charge. Make: Safex, Agni, Ceasefire

28

-

-

... More
S & F of 3 kg light-weight squeeze grip CO2 type fire extinguisher, conforming to IS 15683: 2006, with CO2 gas filled in brand new seamless cylinder with powder coated finish, made out of Manganese steel with wheel type valve, discharge nozzle, bend & horn, wall mounting bracket / floor trolley mounting accessories along with suitable signage complete all as specified and directed by the engineer-in-charge. Make: Safex, Agni, Ceasefire

28

-

-

... More
S & F of 9 litre mechanical foam type fire extinguisher, conforming to IS 15683: 2006, with initial filling in brand new cylinder with powder coated finish, fitted with gunmetal union, high pressure CO2 gas cartridge, hose and ABS type branch pipe and wall mounting bracket / floor trolley mounting accessories along with suitable signage complete all as specified and directed by the engineer-in-charge. Make: Safex, Agni, Ceasefire

8

-

-

... More
S & F of 9 litre water type fire extinguisher, conforming to IS 15683: 2006, with initial filling in brand new cylinder with powder coated finish, fitted with gunmetal union, high pressure CO2 gas cartridge, hose and ABS type branch pipe and wall mounting bracket / floor trolley mounting accessories along with suitable signage complete all as specified and directed by the engineer-in-charge. Make: Safex, Agni, Ceasefire

20

-

-

... More
S & F of the following type of signages made out of 3 mm thick opaque PVC foam board with computer cut, PVC non-reflective self adhesive vinyl painted foam board, complete with mirror fasteners as specified and directed by the engineer-in-charge:-

-

-

-

... More
(a) Sign of size 250 mm X 300 mm reading 'IN CASE OF FIRE, USE STAIRS UNLESS INSTRUCTED OTHERWISE' in 12.5 mm block letters in red and white background, properly spaced to provide good legibility located directly above the call-button and squarely attached to the wall or partition in a way that the top of the sign is not above 2 m from the finished floor level

24

-

-

... More
(b) Sign of size 150 mm X 600 mm, posted and maintained within each stair enclosure on every floor, indicating the number of the floor in bold type and at 75 mm high numerals in red and white background, securely attached to the stair side of the door in a way that the bottom of the sign is not above 1.5 m from the finished floor level

24

-

-

... More
(c) Sign of size 150 mm X 600 mm, posted and maintained at each lift landing and on the side of the stairway door from which egress is to be made on every floor, indicating the lift / lift bank / stairway by an alphabetical letter in bold type and at 75 mm high letters in red and white background, securely attached to the side of the stairway door from which egress is to be made in a way that the bottom of the sign is not above 1.5 m from the finished floor level

24

-

-

... More
Supply and fixing PVC insulated heavy duty unarmoured shield single run copper conductor of 2.5 sqmm 2 core , Fire resistance, working voltage 11 00 volts coMorming to IS: 1554 part -I, drawn through steel conduit for Note: steel cor1duit with conduit accessories shall be measured & paid separately). omplete all as specified and directed.

900

-

-

... More
S & F rigid metalic ERW steel conduit 25 mm exclusives of boxes bl:lt inc/ all Tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as · couplers, Jock nuts, saddles and pipe hooks etc.(6200 Rm copper cable 2.5 sqmm and +200 RM OFC cable) complete all as specified and directed.

850

-

-

... More
Supplying, Installation, Testing and Commissioning of Addressable Telephone with Jack all as specified and as directed

12

-

-

... More
Supply and Fixing 6 kg capacity dry chemical powder (ABC) type fire extinguisher. conforming to IS 15683: 2006, with initial filling in brand new cylinder with powder coated finish, fitted in gunmetal union, high pressure C02 gas cartridge, discharge hose, wall mounting bracket I floor trolley mounting accessories along with suitable signage, etc. complete all as specified and directed by the e.ngineer-in-charge.

38

-

-

... More
S&F light weight squeeze grip type C02 fire extinguisher of 4.5 Kg capacity LIGHT WEIGHT ALUMINUM BODY as per IS: 15683 complete with delivery hose horn, wheel type release valve, locking arrangement, operation manual and bracket. Operating Temperature:- 30°C to +60°C. all as specified and as directed ·

30

-

-

... More
S & F of 9 Ltr capacity Water type fire extinguisher, conforming to IS 15683: 2006, with intial filling in brand new cylinder with Epoxy powder coated, fittied in gun metal cap, Co2 gas filled cartridge with necessary accessories like discharge hose, watt mounting bracket & suitable signage, etc. complete all as specified and directed by engineer-in-charge.

24

-

-

... More
S&F mechanical foam 'stored pressure type fire extinguisher of 9 litre capacity with AFFF Foam con.firming to IS 4989(Part I) with EPDM Hose & air aspirated nozzle, external pure polyester powder coated (UV Resistant) and internal plastic lining, brass forged Valve with safety pin is of Stainless steel material, sheet metal thickness 2 mm as per IS 15683 and IS Marked, complete all as specified and directed.

10

-

-

... More
Supply and fixing Galvanised Iron Fire bucket 9 ltr Red in colour heavy duty all as specified and as directed

8

-

-

... More
S&F auto-illuminated (glow-in-dark) exit sign board with red colour background with appropriate symbol, made up of acrylic. sheet for fire escape in minimum 10 x 6.5 inch size to be pasted on wall with high quality adhesive or to be hanged with s.s. hook-chain system all as specified.

88

-

-

... More
Supply and fixing rechargeable type ceiling/wall mounted Escape lighting showing exit ·sign in green colour provided with in-built battery suitable to provide minimum 90 min contineous lighting after power cut all as specified ..

92

-

-

... More
Supply, install, testing and comm1ss1onmg of indoor cubical type L T , Each Control Board, factory fabricated CPRI type tested with suitabie neoprene rubber gasket to make it completely dust & vermin .proof & degree of protection not less than IP-43 & general construction confirming to IS13947, front & back openable. The panel shall be provided with ventilation facility in the form of louvers for better heat dissipation & tinned copper bus-bar wrapped with coloured PVC tape/sleeves of rating in conformity to the Incoming MCCB rating. The panel board shall be fabricated out of 2.0 mm thick CRCA sheet duly pre-treated & powder . coated, supporting frame made oufof 50 x 50 x 6 mm angle iron suitable , for 3 Ph, 4 wire system 415/440 volts grade inc! complete internal wiring with not less than 2.5 sqmm copper wire inc! cable glands of suitable sizes incl PCC latform/plinth of suitable size complete all as specified & as directed with & incl the following accessories for'Terrace Pump : BUS-BAR & INTERNAL CONNECTIONS: . The bus-bars shall be made up of 04 Nos tinned copper 40 A rated, duly insulated with 1100 V grade standard colour coded PVC sleeves & rigidly mounted on suitable sized "F" class insulators of non-hygroscopic, noncombu~tible, all internal connections form main bus-bars to switcll gears etc. PROVISION FOR CABLE ENTRY : The provision for cable entry/exit shall be provided in the bottom for both incomming & out-going cables.

2

-

-

... More
INCOMING(i) MCCB FP, 25 Amps rating, lcs=100%1cu, 16 kA breaking capacity, adjustable thermal magnetic release- 01 Nos OUTGOING/INSTRUMENTATION SYSTEM: (i) MCCB FP, 25 Amps rating, lcs=100%1cu, 16 kA breaking capacity, adjustable thermal magnetic release- 02 Nos (01 Spare) (ii) Fully Automatic Panel mounted open execution starter suitable upto 10 HP induction motor for Terrace Pump,900 LPM, 415 volts, including overload relay, auto·timer·& single and reverse phase preventer etc complete -02 Nos (01 Spare) (v) Auto Control System for Start/Stop of Terrace Pump controlled through pressure switch (paid separately) and other switching control cable etc from Fire Control Panel with necessary microproceesor controlled relay etc- 01 Set(vi) Digital voltmeter with inbuilt selector. switch, 3 phase, Accuracy Ciass-1.0, Flush mounting 96 x 96 mm, Input Voltage measurement range 50- 520 Volts AC (P-P)- 01 No. (vii) Digital Ammeter with inbuilt selector switch and CT coil with suitable ratio, 3 phase, Accuracy Class-1.0 ,Flush mounting 96 x 96 mm, 4 digit for 0- 20 Amps - 1 No.· (vii)Indicator lamp with LED (red, yellow & blue), Set of Three 01 Set NOTE: (i) Design I drawing of the Panel Board showing the dimensions shall be obtained from Manufacturer I Supplier & shall be got approved from the Dept before placing final order to the manufacturer. (ii) Anything missed oJt in the technical specifications but technically required for efficient working is deemed to be included in the quoted rates.

-

-

-

... More
Supply and fixing 2 Core x 1.5 Sq mm stranded copper conductor Speaker Cable, 11 QO volt grade, Fire resistant, low smoke and halogen free (FRLSH) suitable for Public address system c:lr:awn into concealed steel conduit 20 mm dia all as .specified and directed.

400

-

-

... More
Lightning Protection

-

-

-

... More
Supply and fix aviation light complete all as specified and directed

2

-

-

... More
External water supply

-

-

-

... More
Supply laying jointing & testing centrifugally cast ductile iron pipe class : K-7 with spigot and socket , suitable for Push on rubber joint, with internal cement mortar lining and external metallic coating with finishing layer of black bituminous coating pipes in any lengths confirming to IS:8329-2000 including Rubber Gasket & joints laid in trenches/Road/Ducts/Footpath/on wall/on floor locations for 100 mm dia pipe complete all as specified and directed.

90

-

-

... More
Supply laying jointing & testing centrifugally cast ductile iron pipe class : K-7 with spigot and socket , suitable for Push on rubber joint, with internal cement mortar lining and external metallic coating with finishing layer of black bituminous coating pipes in any lengths confirming to IS:8329-2000 including Rubber Gasket & joints laid in trenches/Road/Ducts/Footpath/on wall/on floor locations for 150 mm dia pipe complete all as specified and directed.

10

-

-

... More
Supply, laying/jointing Ductile Iron Fittings including rubber joint or gaskets(as per fitting requirement) such as bends (any type, radius and angle), heavy duty for spigot & socketed or flanged pipes, tapers any type, radius and angle like straight, bend, increasing, decreasing or double socket etc. Tee piece, single branch 'Y' junction double branch, collar etc. caps and plugs etc. with internal cement mortar lining , and external zinc and black bitumen coated complete all as specified and directed.

150

-

-

... More
M & L for brick masonry valve chamber of size 1.10m x 1.10m x 0.9m (internal dimension) with 15cm thick foundation using PCC 1:4:8 type D-2 (using 40mm graded stone aggregate) over 15cm thick hardcore, 23cm thick brick wall built in cement and sand mortar (1:4), 10mm thick internal and external plaster including top of floor in cement and sand mortar 1:3 finished even and smooth, without using extra cement, 10mm thick MS sheet cover with, 50mm x 50mm x 6mm MS angle frame embedded in PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) coping having rectangular hinged opening of size with locking arrangements & handle made out of 25cm dia MS round bar, hold fasts etc applying one coat of red oxide primer and two coats of synthetic enamel paint to all steel surface including excavation, refilling and earth work in any type of soil and disposal of surplus soil to a distance n.exc 50m complete all as specified.

8

-

-

... More
M&L for RCC valve chamber of size 1.45X1.45X3 meter (outer dimension) with thickness of 0.15m with complete form work , including provision of MS ladder of 2 meter height with L channel (50X50X5) to be fitted along with RCC chamber by means of fasteners, including foundation of 100mm thick ness with PCC (1:4:8) 20mm aggregate , including MS top cover with hinge and handle arrangement of thickness 5mm with angle channels to be fitted on copping , plastering of chamber 10mm grith of 1:6 ratio cement mortar complete all as specified and directed. Note : the quoted rate shall include the excavation and removal in any type of soil/rock, 10mm reinforcement Fe 410 of span 10 C/C through out the chamber upto 3 meter height with base of same span , ring of 10mm dia reinforcement of span 10 C/C through out the chamber shall be used and binded with annealed wire of 0.9 mm in complete chamber. PCC (1:2:4) 20mm aggregate of nominal mix shall be used for the RCC structure.

1

-

-

... More
Supply install testing, commissioning & calibration of 100 mm Analog water Flow Meter Class B all as per manufacturer design and as directed.

1

-

-

... More
External Electrification

-

-

-

... More
Supply, install, test and commission step down transformer, indoor type, and conforming to IS 1180 Level 1 as per latest amendment 2021, mounted on foundation, HT 11 KV, 3 phase 433 volts, 4 wire, 50 Hz, delta/star connected, vector group DYN -11 copper wound, ONAN, manual type off load tap changing facility on HT side to vary secondary voltage from minus 7.5% to plus 7.5% in steps of 2.5 %, continuous rating of capacity 400 KVA including bushing on HT and LT end. The Transformer shall be complete with all standard fittings and accessories, gauges, first fill of transformer oil IS 335 ISI marked filtered & dehydrated oil etc, complete all as specified and directed by Engineer In charge and comprising of the following accessories :-

1

-

-

... More
Note :- Transformer shall be mounted on foundation as per manufacturer's instruction / specifications. (a) One cable box on primary HV side having cable glands suitable for conductor(consisting of 3 Nos porcelain HT bushings with brass/gun metal bushing rods complete with nuts and washers). (b) One cable box on secondary (LV) side consisting of 4 Nos porcelain bushing with GM bushing rods complete with GM nuts, and washers with one No cable gland suitable for reception of outgoing LT armoured cables of suitable size. (c) Oil conservator tank with filter type, drain valve and oil level gauge. (d) Dehydrating breather with first fill of dehydrating agent. (e) Thermometer pocket on tank cover. (f) One No 100mm dia dial type thermometer vapour pressure type having range 0-120 degree centigrade with temp reading pointer, max temp indicator and resetting with marshalling box. (g) Rating plate with terminal markings. (h) Two earthing terminals on tank/tank cover to facilitate fixing of 32x6m Gl earth strip. (i) Explosion vent. (j) Oil level gauge. (k) Oil drain and filter valves. (l) Oil filler hole with cap/plug with connections all as specified and directed by Engineer In charge. (m) Lifting lugs. (n) Air relief valve plug. (o) Four solid cast steel detachable rollers. (p) First fill of fresh oil conforming to relevant IS and tested upto 50 KV dielectric strength upto maximum indicator level. (q) Extra bushing for neutral outside the LT cable box for providing independent earthing for neutral. (r) Provision of 2 Nos danger boards 250x200mm size made out of 1.6mm thick MS plate, vitreous enamelled white, with letters, figures of voltage and conventional skull and bones in signal red colour, one at HT side and other on LT side. (s) Any other fittings/accessories so as to confirm the whole transformer to IS-1180(Level-l as per amendment 2021).

-

-

-

... More
M & L for chemical earthing Electrode Outer Pipe in Gl and having minimum diameter of 76mm & 3mtr In length Inner pipe to have minimum diameter of 32mm Both ends properly welded to make them airtight GI Terminal size of 100X50X6mm with 2 nos M8 holes for Termination Area in between 2 pipes filled with Dry type chemical powder having high conductivity with no air pockets Electrode must be tested for Short Circuit Test of minimum 40kA at CPRI/NABL, the back fill compound should be carbide based having very high electrical conductivity and high water retaining capacity complete including Earth Pit Cover Square 300X300X240mm to be provided to cover the Earth pit all including boring (120mm dia , 3.5m depth) installation transportation earth work testing soil condition connected to and incl GI strip 32x6mm and GI pipe 40 mm dia light grade for protection to the extent of 7.5 m as earthing lead by means of GI bolts and nuts etc connecting to equipment and including PVC cover incl excavation and earth work in any type of soil and testing on completion etc complete (DG SET-4, Ext Elec-6) NOTE: - The quoted rate shall include supply and fixing PVC syntex box (side open) with clamps including base insulator for mounting of test point terminal block( including) made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed and connecting GI earth strip 32x6mm. Earth strip and protection pipe beyond 7.5m will be measured and paid separately

10

-

-

... More
Supply, installation, testing and commissioning of factory made, CPRI type tested, indoor cubical compartmental type of suitable size,, having both sides openable with hinged single doors and locking arrangement, IP 43 protection made out of 2.0 mm thick mild steel CRCA sheet, supported and fixed on structural frame of angle iron of suitable size, including earthing stud, labelling, painting to all internal & external exposed steel surfaces with powder coating paint (7 tank process), duly fixed in ground with PCC foundation (1:2:4) type B1, with danger notice plate of 1.6 mm thick mild steel vitreous enamelled (white) with letters, figures and conventional skull and bones in signal red colour suitable for 3- Phase, 4 Wire system, 500 V grade with necessary wiring, PVC sheathed stranded copper conductor of appropriate length and size, including fixing lugs, bolts, screws, etc. complete all as specified and directed by engineer-in-charge. The MAIN LT PANEL shall comprise of the following:

1

-

-

... More
Busbar Chamber: [i] 01 Set (3L + N) of copper busbar of rated capacity 1200 A, covered with PVC insulated sleeves with colour code including insulator, nuts, bolts, etc. with complete connection Incoming: [i] 800 A, 415 V, Ics = Icu = 50 kA, 50 Hz, electrical draw-out type FP ACB with microprocessor based ET trip system with thermal memory, zone selective interlocking, fully rated neutral with inbuilt protection, pre-trip alarm & individual fault indicating LEDs and overload, short-circuit, instantaneous & earth- fault protection-01 Nos. [ii] Cl 1.0 multi-function meter capable of measuring V, A, F, PF, W/VA, Wh/VAh, Runhrs. Onhrs & interrupts- 01 Nos. [iii] LED phase indicators (Red, Yellow, Blue)- 01 Set Outgoing: [i] 250 A, 415 V, Ics = Icu = 35 kA, 50 Hz, 4P MCCB with microprocessor based release - 02 Nos( Bldg 1 & 2) [ii] 320 A, 415 V, Ics = Icu = 36 kA, 50 Hz, 4P MCCB with microprocessor based release - 01 Nos (APFC Panel) [iii] 160 A 415V, Ics = Icu = 35 kA, 50 Hz, 4P MCCB with microprocessor based release - 01 Nos (Essential panel) [iii] LED phase indicators (Red, Yellow, Blue)- 5 Set [vi] CL 1.0 multi-function meter capable of measuring V, A, F, PF, W/VA, Wh/VAh, Runhrs. Onhrs & interrupts-5 Nos. [v] Space for 320A 4P MCCB to be provided in panel.

-

-

-

... More
Supply, installation, testing and commissioning of factory made, CPRI type tested, indoor cubical compartmental type of suitable size, having both sides openable with hinged single doors and locking arrangement, IP 43 protection made out of 2.0 mm thick mild steel CRCA sheet, supported and fixed on structural frame of angle iron of suitable size, including earthing stud, labelling, painting to all internal & external exposed steel surfaces with powder coating paint (7 tank process), duly fixed in ground with PCC foundation (1:2:4) type B1, with danger notice plate of 1.6 mm thick mild steel vitreous enamelled (white) with letters, figures and conventional skull and bones in signal red colour suitable for 3- Phase, 4 Wire system, 500 V grade with necessary wiring, PVC sheathed stranded copper conductor of appropriate length and size, including fixing lugs, bolts, screws, etc. complete all as specified and directed by engineer-in-charge. The ESSENTIAL LOAD PANEL shall comprise of the following:

1

-

-

... More
Busbar Chamber: [i] 01 Set (3L + N) of copper busbar of rated capacity 250 A, covered with PVC insulated sleeves( colour code) including insulator, nuts, bolts, etc. with complete connection Incoming: [iii] 160 A 415V, Ics = Icu = 35 kA, 50 Hz, 4P MCCB with microprocessor based release - 01 Nos [ii] CL 1.0 multi-function meter capable of measuring V, A, F, PF, W/VA, Wh/VAh, Runhrs. Onhrs & interrupts- 01 Nos. [iii] LED phase indicators (Red, Yellow, Blue)- 01 Set Outgoing: [iii] 100 A 415V, Ics = Icu = 35 kA, 50 Hz, 4P MCCB with microprocessor based release - 03 Nos ( Bldg 1 & 2 , spare) [iii] 32 A, 230, 10 KA, 50 Hz, FP MCB - 3 Nos.( street light panel, spare) [iii] LED phase indicators (Red, Yellow, Blue)- 3 Set [iv] CL 1.0 multi-function meter capable of measuring V, A, F, PF, W/VA, Wh/VAh, Runhrs. Onhrs & interrupts-3 Nos.

-

-

-

... More
Supply, installation, testing and commissioning of factory made, CPRI type tested, indoor cubical compartmental type of suitable size,, having both sides openable with hinged single doors and locking arrangement, IP 43 protection made out of 2.0 mm thick mild steel CRCA sheet, supported and fixed on structural frame of angle iron of suitable size, including earthing stud, labelling, painting to all internal & external exposed steel surfaces with powder coating paint (7 tank process), duly fixed in ground with PCC foundation (1:2:4) type B1, with danger notice plate of 1.6 mm thick mild steel vitreous enamelled (white) with letters, figures and conventional skull and bones in signal red colour suitable for 3- Phase, 4 Wire system, 500 V grade with necessary wiring, PVC sheathed stranded copper conductor of appropriate length and size, including fixing lugs, bolts, screws, etc. complete all as specified and directed by engineer-in-charge. The OFFICER BUILDING PANEL shall comprise of the following:

2

-

-

... More
[i] 01 Set (3L + N) of copper busbar of rated capacity 400 A, minimum current density, covered with PVC insulated sleeves (colour code) including insulator, nuts, bolts, etc. with complete connection Incoming: [i] 250 A, 415 V, Ics = Icu = 35 kA, 50 Hz, 4P MCCB with microprocessor based release - 01 Nos [ii] CL 1.0 multi-function meter capable of measuring V, A, F, PF, W/VA, Wh/VAh, Runhrs. Onhrs & interrupts- 01 Nos. [iii] LED phase indicators (Red, Yellow, Blue)- 01 Set Outgoing: [iii] 160 A 415V, Ics = Icu = 35 kA, 50 Hz, 4P MCCB with microprocessor based release - 03 Nos( Right wing, left wing, spare) [ii] LED phase indicators (Red, Yellow, Blue)- 3 Set [iii] CL 1.0 multi-function meter capable of measuring V, A, F, PF, W/VA, Wh/VAh, Runhrs. Onhrs & interrupts-4 Nos.

-

-

-

... More
M&L GI Octagonal poles complete with single arm bracket as specified all for 9 mtrs long with 70 mm top dia and 130 mm bottom dia, made of 3 mm thick tensile sheet alongwith base plate of size 225x225 x12 mm thick incl 04 nos. of M24 x750 long J type foundation bolts incl 6A MCB with 4 way heavy duty contactor 32 A , including PVC 3 core wire 2.5 sqmm from MCB to light complete with its foundation all as specified by the pole manufacturer all as specified and directed by E-in-Charge Note the quoted rate shall include the necessary earthwork complete such as excavation, removal, RCC foundation, formwork etc.

20

-

-

... More
Supply and fixing of Security/Street light control panel outdoor type made out of 3.15 mm thick CRCA sheet totally enclosed conforming to relevant IS/IEC, CPRI type tested and suitable bus bar including angle iron frame made out of 40x40x 5 mm angle duly powder coated with 60 cm legs duly grouted with PCC complete all as specified and as directed comprising the following :- (a) MCCB TPN 32 Amps, 415 Volts, AC, 50 Hz, 10 KA rupturing capacity as incoming - 01 No (b) MCB TPN 32 Amps, 415 Volts, AC, 50 Hz, 10 KA rupturing capacity as outgoing - 02 Nos (c) Power contactor 3 Pole, AC, 3 rating, 40 Amps coil voltage 240 Volts - 02 Nos (d) Digital timer for controlling the contactor, single phase, 230 Volts AC (e) MCB SP 06 Amps, 230 Volts, AC, 50 Hz - 03 Nos (f) Switch socket combination multipurpose 2 in 1, 3 pin, 5 and 15 Amp flush type universal complete. 01 Nos (g) Indicator lamps (RYB) - 01 Set (h) Digital multi functional Multimeter for showing Volts/ Amps/PF etc alongwith suitable rating CT coil - 01 Set (i) Control wiring for automatic operation of street lights with by pass arrangement all as specified and as directed. (j) Incoming and outgoing terminals for suitable cable

1

-

-

... More
Rain Water Harvesting

-

-

-

... More
M&L for 200 mm perforated PVC pipe complete all as specified as directed

12.63

-

-

... More
M&L for 250 mm perforated PVC pipe complete all as specified as directed

12.63

-

-

... More
Prepaid energy meter

-

-

-

... More
S&F RF based three phase four wire energy meter complete all as specified and directed with the following specifications :- (i) Smart meter three phase four wire energy meter BIS 16444 2015 (Reaffirmed 2020) marked with transparent encloser having current range 10-60Amps,240 Volts accuracy class 1.0 with inbuilt 865-867 MHz Radio frequency communication facility ,anti temper features ,Microprocessor and LED LCD based circuitry. (ii) Meter should be support sending the following data to the software : 15/30 min instantaneous data for voltage ,current ,PF, percolative energy and frequency ,monthly billing survey for cumulative energy and max demand. (iii) Meter should have connect/disconnect functionally operable from prepaid billing software. (iv) Meter should support open communication protocol DLMS with the software. (v) Make :- Secure,L&T,Schnieder Note :- The smart meter should be capable of running in both prepaid and postpaid mode and the meter should carry five year warranty

40

-

-

... More
S&F RF based single phase two wire energy meter complete all as specified and directed with the following specifications :- (i) Smart meter three phase four wire energy meter BIS 16444 2015 (Reaffirmed 2020) marked with transparent encloser having current range 10-60Amps,240 Volts accuracy class 1.0 with inbuilt 865-867 MHz Radio frequency communication facility ,anti temper features ,Microprocessor and LED LCD based circuitry. (ii) Meter should be support sending the following data to the software : 15/30 min instantaneous data for voltage ,current ,PF, percolative energy and frequency ,monthly billing survey for cumulative energy and max demand. (iii) Meter should have connect/disconnect functionally operable from prepaid billing software. (iv) Meter should support open communication protocol DLMS with the software. (v) Make :- Secure,L&T,Schnieder Note :- The smart meter should be capable of running in both prepaid and postpaid mode and the meter should carry five year warranty

40

-

-

... More
Supply and installation IP-67 Data Concentrator Unit (DCU) compatible for remote Automatic Metering Infrastructure(AMI) solution and capable of communicating with the smart energy meter in the corresponding frequency band with the data server through GPRS/Ethernet , It should have internal memory to store data of atleast 200 modules . It should have internal battery back up IP-67 protection. It should support auto discovery of the meters and self- healing mechanism for the breaks in the risk in the RF network. complete all as specified and directed. Make :- Secure,L&T,Schnieder

1

-

-

... More
Supplying and fixing of RF based smart three phase four wire energy meter with the following specification :-Smart Three Phase four wire energy meter BIS 16444 2015 (Reaffirmed 2020) marked in existing mete( board I floor panels having current range 10-60Amp, 415 Volts accuracy class 1.0 with inbuilt 865-867 MHz Radio frequency communication facility with healing Mesh netwrok with default and on demand display, billing data generation facility, anti tamper features, rcroprocessor and LED/LCD based Circuit complete all as specified and directed. (40 Nos for Offrs Accn and 2 Nos forcommon utility service for 2 Nos offrs DU) Note : -(a) Meter should support sending the following data to the software: 15/30 min instantaneous data for voltage, current, power factor, power cumulative energy and frequency, monthly billing survey for cumlative energy and max demand. (b) Meter should have connect I disconnect functionality operable from prepaid billing software.(c) The Meter should support open cummunication protocol DLMS with the software (c) The Meter should support open cummunication protocol DLMS with the software

80

-

-

... More
Supplying and fixing of RF based smart three phase four wire energy meter with the following specification :-Smart Three Phase four wire energy meter BIS 16444 2015 (Reaffirmed 2020) marked in existing mete( board I floor panels having current range 10-60Amp, 415 Volts accuracy class 1.0 with inbuilt 865-867 MHz Radio frequency communication facility with healing Mesh netwrok with default and on demand display, billing data generation facility, anti tamper features, rcroprocessor and LED/LCD based Circuit complete all as specified and directed. (40 Nos for Offrs Accn and 2 Nos forcommon utility service for 2 Nos offrs DU) Note : -(a) Meter should support sending the following data to the software: 15/30 min instantaneous data for voltage, current, power factor, power cumulative energy and frequency, monthly billing survey for cumlative energy and max demand. (b) Meter should have connect I disconnect functionality operable from prepaid billing software.(c) The Meter should support open cummunication protocol DLMS with the software (c) The Meter should support open cummunication protocol DLMS with the software

80

-

-

... More
TV-TELEPHONE CONDUITE

-

-

-

... More
S & F modular type 1 module RJ 11 telephone socket with shutter complete all as specified and directed. Make: Legrand Arteor Cat-Part No. 5734 26 or techno commercially equivalent model of Anchor Cat-Part No. 20857 or L & T Cat-Part No. CB92101TW11

80

-

-

... More
S & F modular type 1 module TV socket complete all as specified and directed. Make: Legrand Arteor Cat-Part No. 5734 25 or techno commercially equivalent model of Anchor Cat-Part No. 21157 or L & T Cat-Part No. CB92101TW00

80

-

-

... More
S & F Modular type TV socket Co-axial outlet 1 Module in the modular MS I flush metal Gl Box and cover plate excluding concealed 25mm PVC conduit in wall/ceiling/fixed to roof, connections etc complete all as specified and directed

42

-

-

... More
Supply and instalation IP-67 Data Concentratr Unit (DCU) compatible for remote Automatic Metering lnfrastructure(AMI) solution and capable of communicating with the smart energy meter in the corrosponding frequency band wuth the data erver through GPRS/Eithenet, It should have internal memory to tore data of atleast 200 modules . It should have internal battery back up IP-67 protection . It should upportautodiscovery of the meters and self- healing mechanism for the breaks in the risk in the RF network. (v) Make:· Secure,L&T,Schnieder

1

-

-

... More
DG SET

-

-

-

... More
Supply, install, testing and commissioning of Silent Diesel Engine Generating Set, 100 kVA / 80 KW (3-Ph), water cooled, powered with Engine developing minimum 126.5 BHP at 1500 RPM, coupled with 415 V, 50 Hz, 3 phase, 0.8 p.f, suitable alternator, 12V Battery with ARAI approved acoustic enclosure & compliance to CPCB–IV+ norms along with MCCB based AMF logic control panel & SMPS battery charger, tools and spares complete all as specified and directed and comprising of the following:-

1

-

-

... More
(a) Engine : Diesel engine, 4 cylinder engine developing required minimum 126.5 BHP @ 1500 RPM for prime rating of suitable for 100 KVA alternator confirming to BS 5514/1SO 3046 and revised editions as applicable standard Totally enclosed, electric star, compression ignition, 4 stroke. The engine shall consists of following specifications:- 1. Mechanical FIP 2. Mechanical governor 3. Turbocharger, exhaust manifold, stainless steel exhaust flexible connection 4. Radiator Cooled with after cooled 5. Plate type lube oil cooler 6. Filter-fuel, lube oil 7. Dry type replaceable paper element air cleaner 8. Flywheel housing and flywheel to suit single bearing alternator 9. Starting motor – Electric, battery charging alternator 10. First fill lube oil and coolant (b) Alternator: Alternator rated 100KVA , 0.8 PF, 415 V, 3 Phase ,4 Wire ,4 pole , 50HZ with standard design band of voltage regulation +/- 1% from no load to full load and comprising of following specifications:- 1. brushless alternator 2. Self-excited, self-regulated 3. Class ‘H’ insulation 4. Salient pole revolving field 5. Single bearing sealed type 6. Automatic voltage regulator (c) Acoustic enclosure: – Engine alternator assembly mounted on AVM with Silencer and S.S exhaust bellow suitably optimized to meet stringent sound emission standards as laid down by MOEF / CPCB. Base rail with draw-out type fuel tank with capacity 250 Ltr is provided with a drain plug air Vent inlet and outlet connections, level indicator, manhole etc. Sub-base fuel tank with 13 hours capacity at 75% load. 12 V 88AH dry, batteries with connecting leads and terminals complete.

-

-

-

... More
(d) Control panel: Powder coated control panel manufactured with CRCA sheet provides: 1. MCCB of suitable rating with overload and short circuit protection 2. Controller which displays voltage, current, KW, PF, Frequency, KWh. 3. Indicating lamps for “Load On” and “Set Running” 4. Current transformers of suitable ratings 5. Copper cable of suitable capacity with incoming and 6.Outgoing terminations 7. Control fuses duly wired and ferruled (e) Power cables: Unenvying copper conductor cables between Alternator & Control panel inside the canopy (f) Electrical Systems: Alternator Space Heater / Higher Rating Battery / Battery Charger / Copper Bus Bar / Sealable kWh / Earth Fault Relay / Remote Annunciator / Remote monitoring / Type RTD/BTD Temperature Scanner (g) Exhaust Silencer - Hospital / Residential grade, stainless steel, flexible pipe. Fuel System: Flexible Fuel Lines / SS fuel lines / Fuel Pressure Gauge Enclosed Unit: Sound Enclosure – Super silent / External 990 Lt. Fuel Tank. Miscellaneous: Air Cleaner (Heavy Duty)/Air Cleaner Restriction Indicator Digital / Closed crankcase ventilation (h) AMF &Synchronizing System: AMF panel / AMF with Auto-synchronization with all necessary control units, MCCBs/ contactors, MCBs etc complete set ready to operate including necessary cable connections. (j) Generator control: The generator control consists of :- 1. Display parameters : Engine oil pressure, coolant temperature, fuel level indication%, battery voltage, Engine RPM, DG set running hours, Generator volts - Ph to N, Ph to Ph, Current, PF, KWHR, KW 2. Audio visual warning : Low Oil pressure, High coolant temperature, Low battery voltage, Low fuel level 3.Shut down with audio visual annunciation :- Low Oil pressure, High coolant temp, Engine over speed, engine under speed, low fuel, under voltage, over voltage, over and under frequency 4. Other features : Compact and microprocessor based fully configurable control unit with all necessary wirings,MCBs etc , graphic display Note : Quoted rate shall be deemed to include any other technical requirement items & PCC foundation , excavation , removal of soil if any shall be included and quoted in this item only.

-

-

-

... More
MODULAR KITCHEN ITEMS

-

-

-

... More
S&F perforated cutlery basket of size 530x505x100mm fabricated, purpose made with stainless steel of grade 340, not less than 6 to 8 Kg each rack, using square hollow tubes for frame work and solid round bars / 26 gauge thick sheet to make desired pattern, suitable for sliding under kitchen platform on a pair of channels, including fixing with steel screws, fixed in repairs, complete all as specified and as directed by Engineer-in-Charge. Make : Classic or approved equivalent model of make by CWE. NOTE :- Telescopic channels shall be measured and paid separately under respective items of BOQ.

1

-

-

... More
S&F stainless steel cup & saucer 530x505x100mm, fabricated purpose made with each stainless steel of grade 340, not less than 6 to 8 Kg each rack, using square hollow tubes for frame work and solid round bars / 26 gauge thick sheet to make desired pattern, suitable for sliding under kitchen platform on a pair of channels, including fixing with steel screws, fixed in repairs, complete all as specified and directed by Engineer-in-Charge. Make : Classic or approved equivalent model of make by CWE. NOTE :- Telescopic channels shall be measured and paid separately under respective items of BOQ.

1

-

-

... More
S&F perforated thali of size 530x505x200mm fabricated purpose made with each stainless steel of grade 340, not less than 6 to 8 Kg each rack, using square hollow tubes for frame work and solid round bars / 26 gauge thick sheet to make desired pattern, suitable for sliding under kitchen platform on a pair of channels, including fixing with steel screws, fixed in repairs, complete all as specified and as directed by Engineer-in-Charge. Make : Classic or approved equivalent model of make by CWE. NOTE :- Telescopic channels shall be measured and paid separately under respective items of BOQ.

1

-

-

... More
S&F plain basket 710x505x200 mm size fabricated purpose made with stainless steel of grade 340, not less than 6 to 8 Kg each rack, using square hollow tubes for frame work and solid round bars / 26 gauge thick sheet to make desired pattern, suitable for sliding under kitchen platform on a pair of channels, including fixing with steel screws, fixed in repairs, complete all as specified and as directed by Engineer-in-Charge. Make : Classic or approved equivalent model of make by CWE. NOTE :- Telescopic channels shall be measured and paid separately under respective items of BOQ.

1

-

-

... More
S&F fixed pull out 3 shelf, fabricated purpose made with stainless steel of grade 340, not less than 6 to 8 Kg each rack, using square hollow tubes for frame work and solid round bars / 26 gauge thick sheet to make desired pattern, suitable for sliding under kitchen platform on a pair of channels, including fixing with steel screws, fixed in repairs, complete all as specified and as directed by Engineer-in-Charge. Make : Classic or approved equivalent model of make by CWE. NOTE :- Telescopic channels shall be measured and paid separately under respective items of BOQ.

1

-

-

... More
S&F fixed multipurpose double tier 456x170x450 mm fabricated purpose made with stainless steel of grade 340, not less than 6 to 8 Kg each rack, using square hollow tubes for frame work and solid round bars / 26 gauge thick sheet to make desired pattern, suitable for sliding under kitchen platform on a pair of channels, including fixing with steel screws, fixed in repairs, complete all as specified and directed by Engineer-in-Charge. Make : Classic or approved equivalent model of make by CWE. NOTE :- Telescopic channels shall be measured and paid separately under respective items of BOQ.

1

-

-

... More
S&F Telescopic channels soft closing, powder coated with ball bearings, suitable for sliding SS plate racks, 60 cm long, standard width, fixed over second class hard wood rectangular fillet sectional area exc. 3 sq.cm & n.exc. 6 sq.cm, clean swan secured with screws and the fillet fixed on Cuddappa stone with screws, all as specified and as directed.

14

-

-

... More
S&F stainless steel handle oval shape fabricated type anodized 150mm long of approved design, shape and make fixed in repairs with nut screws & washers complete with ISI mark all as specified and as directed.

7

-

-

... More
S&F stainless steel finish soft closing hinges approved design, shape and make fixed in repairs with nut screws & washers complete with ISI mark all as specified and as directed.

12

-

-

... More
S & F of 18mm thk marine plywood as per IS 710 laminated of any colour with high glossy acrylic sheet of 3mm thk grade I of frame & shutter for kitchen cabinets complete all Specified & directed

8.15

-

-

... More
MISCELLANEOUS ITEM S&F retro reflective sign board of size 4' x 3' fixed both sides on stainless steel board made out of aluminium composite panel (ACP) sheet, 3mm thick fixed on SS-304 series hollow tubular section, 38mm dia. The board shall be provided with reflective tape of quality high intensity chequered type blue colour, letter/symbol shall be written in white colour writing of approved shape. The sign board shall be supported on 2 NOs post of 60mm dia stainless steel pipe, 304 series 3mtr long with round moulded design on top duly embedded in ground etc as directed by Engineer-in-Charge.

2

-

-

-

-

-

... More
Supply, install, testing & commissioning of 08 Passengers Lifts (544 Kg) suitable to serve G+5 upper floors with AC variable voltage & variable frequency (VVVF) drive complete with all standard accessories, simplex collective automatic & manual dual controlled operation with/without attendant, automatic centre opening doors with VVVF door drive (electric motor driven mechanism), sliding stainless steel doors, automatic rescue device (ARD) system, Over load device, 3D infra red sensor in full height of door & built in announcing system with hand set (02 Nos), one each in car & near Ground floor landing door and one with hand set in Machine room) complete all as specified below :- MAKE :- OTIS, KONE, THYSSEN KRUPP, SCHINDLER, MITSUBISHI, HITACHI, TOSHIBA

2

-

-

... More
(a) Type of Lifts : 08 Passengers (b) Load capacity : 544 Kg (c) Speed : 1.5 mtr/sec with variable speed motor (d) Power Supply : 415 volts, 3 phase AC, 50 Hz (e)Type of Drive : AC variable voltage & variable frequency drive along with converter unit. (f) Type of Machine : Low inertia gearless permanent magnet Synchronous motor, directly coupled Horizontal traction machine. (g) Car size (Inside) : Not less than 1.43Sqm. (h) Car door & landing door at all floors : Automatic Centre / opening with VVVF door drive, opening size not less than 800 mm x 2000 mm, sliding type, fabricated by stainless steel sheet as per OEM. (i) Car enclosure: (i) Manufactured with stainless steel frame stainless steel sheet as per OEM with hair line finish (N-304) having stainless steel false ceiling with hair line finish, internal lighting arrangement with Four Nos LED light fitting for commercial supply and one No LED for emergency light, internal ventilation system provided with concealed arial flow/cross flow fan with auto cut off system and stainless steel grill/wire mesh for protection. (ii) Provision of standard thickness stainless steel hand rail 40mm dia inside the car cabin. (1 Sides) (j)Terminal buffers : Metal special spring/oil buffers as per manufacturer specification. The buffing stroke should not be less than 200mm. (k) Door opening (Inside) : Protected by centre opening stainless steel doors with hairline finish doors with clear opening size not less than 800 x 2000mm . (l) Car & counter weight Guide : Guide rails of `T' Section Mild steel as per OEM design. Counter weight shall be cast iron as recommended by OEM. (m) Flooring : Granite not less than 18mm thick (o) Signals: (i) Combined luminous hall buttons with LCD/VFD hall position indicators at all floor. (ii) LCD/VFD for car position indicator to be fitted in COP made of stainless steel. (iii) One No car operating panel with luminous buttons in car (stainless steel). (iv) Car direction indicator in car & Landing (v) Battery operated alarm bell & emergency light (rechargeable) along with suitable maintenance free battery. (This system should be separate from ARD batteries). (vi) Overload warning feature in car cabinet(Display & announcing both type). (vii) Fireman’s switch one No per lift to be installed at ground Floor near landing door. (viii) All signal fixture & car operating panel on stainless steel face plate with hair line finish.

-

-

-

... More
(ix) Infra red door sensor safety edge of door for entire height. (x) Built in announcing system with hand set.02 Nos (One for lift car & ground floor landing door & one announcing system with hand set in machine room). (p) Stops & Opening : 6-6 Stop and centre opening at all floors. (q) Safety Device : (i) Automatic rescue device (ARD)/Automatic landing device with maintenance free battery having suitable capacity. The ARD panel must have auto charging facilities for battery. (ii) The ARD actuation should be after failure of power supply and when ARD is operative the car should stop at the nearest floor and then automatically open. (r) Operation: Simplex, full collective automatic operation with/without attendant. (s) Machine Room : Located about the hoist way (details as per Bldg drg) (t) Hoist-Way Constn : Existing at site, details as per Bldg drg (u) Civil Work : Necessary Civil work such as making good disturbed surface, modification to landing space to suits to car size necessary foundation to machine. (v) Control system : shall be enclosed loop type. (w) Door shall have AC-VVVF controlled close loop operated. (x) Face plate shape shall be rectangular and stainless steel with hairline finish. (y) counter weight shall be of cast iron or as recommended by OEM. (z) One number wall mounted type telephone instrument of make Crompton Greaves / Beetel /OEM own make installed inside of car cabin along with fixing arrangement and telephone cable of suitable size from car cabin to machine room run along with trailing cable. The telephone instrument shall be connected in the telephone DB installed in the machine room. (za) One number electrically operated siren, operating voltage 240 volts having audible range of 0.5 Km of Make : KHERAJ Model No SS050 /OEM own make alongwith One Number inverter unit of suitable capacity but not less than 0.5KVA comprising of maintenance free battery connected with charging system including a separate switch/push button inside of car panel and electric wiring circuit upto the machine room. The siren shall be installed over the building at appropriate place and to be operated from inside the car. (zb) 5 W LED light Fixture (5 nos.) (zc) 250 mm sweep Fan (1 nos.) NOTE :- The contractor shall obtain necessary approval from local / state / Central Government Authority and make arrangement for inspection & test required. Contractor shall submit required certificate/license from competent authority before commissioning/ handing over or as directed by Engineer-in-charge

-

-

-

... More
Supply, install, testing & commissioning of 13 Passengers Lifts ( 884 kg) suitable to serve G+5 upper floors with AC variable voltage & variable frequency (VVVF) drive complete with all standard accessories, simplex collective automatic & manual dual controlled operation with/without attendant, automatic centre opening doors with VVVF door drive (electric motor driven mechanism), sliding stainless steel doors, automatic rescue device (ARD) system, Over load device,3D infra red sensor in full height of door & built in announcing system without hand set (02 Nos, one each in car & near Ground floor landing door and one with hand set in Machine room) complete all as specified below :- MAKE :- OTIS, KONE, THYSSEN KRUPP & SCHINDLER, MITSUBISHI, HITACHI, THOSHIBA

2

-

-

... More
(a) Type of Lifts : 13 Passengers (b) Load capacity : 884 kGs (c) Speed : 1.5 mtr/sec with variable speed motor (d) Power Supply : 415 volts, 3 phase AC, 50 Hz (e)Type of Drive : AC variable voltage & variable frequency drive along with converter unit. (f) Type of Machine : Low inertia gearless permanent magnet Synchronous motor, directly coupled Horizontal traction machine. (g) Car size (Inside) : Not less than 2.20 Sqm. (h) Car door & landing door at all floors : Automatic Centre opening with VVVF door drive, opening size not less than 900 mm x 2000 mm, sliding type, fabricated by stainless steel sheet as per OEM. (i) Car enclosure: (i) Manufactured with stainless steel frame stainless steel sheet as per OEM with hair line finish (N-304) having stainless steel false ceiling with hair line finish, internal lighting arrangement with Four Nos LED light fitting for commercial supply and one No LED for emergency light, internal ventilation system provided with concealed arial flow/cross flow fan with auto cut off system and stainless steel grill/wire mesh for protection. (ii) Provision of standard thickness stainless steel hand rail 40mm dia inside the car cabin. (3 Sides) (j)Terminal buffers : Metal special spring/oil buffers as per manufacturer specification. The buffing stroke should not be less than 200mm. (k) Door opening (Inside) : Protected by centre opening stainless steel doors with hairline finish doors with clear opening size not less than 900 mm x 2000 mm . (l) Car & counter weight Guide : Guide rails of `T' Section Mild steel as per OEM design. Counter weight shall be cast iron as recommended by OEM. (m) Flooring : Granite not less than 18mm thick (o) Signals : (i) Combined luminous hall buttons with LCD/VFD hall position indicators at all floor. (ii) LCD/VFD for car position indicator to be fitted in COP made of stainless steel. (iii) One No car operating panel with luminous buttons in car (stainless steel). (iv) Car direction indicator in car & Landing (v) Battery operated alarm bell & emergency light (rechargeable) along with suitable maintenance free battery. (This system should be separate from ARD batteries). (vi) Overload warning feature in car cabinet(Display & announcing both type). (vii) Fireman’s switch one No per lift to be installed at ground Floor near landing door. (viii) All signal fixture & car operating panel on stainless steel face plate with hair line finish.

-

-

-

... More
(ix) Infra red door sensor safety edge of door for entire height. (x) Built in announcing system with hand set.02 Nos (One for lift car & ground floor landing door & one announcing system with hand set in machine room). (p) Stops & Opening : 6-6 Stop and centre opening at all floors. (q) Safety Device : (i) Automatic rescue device (ARD)/Automatic landing device with maintenance free battery having suitable capacity. The ARD panel must have auto charging facilities for battery. (ii) The ARD actuation should be after failure of power supply and when ARD is operative the car should stop at the nearest floor and then automatically open. (r) Operation: Simplex, full collective automatic operation with/without attendant. (s) Machine Room : Located about the hoist way (details as per Bldg drg) (t) Hoist-Way Constn : Existing at site, details as per Bldg drg (u) Civil Work : Necessary Civil work such as making good disturbed surface, modification to landing space to suits to car size necessary foundation to machine. (v) Control system : shall be enclosed loop type. (w) Door shall have AC-VVVF controlled close loop operated. (x) Face plate shape shall be rectangular and stainless steel with hairline finish. (y) counter weight shall be of cast iron or as recommended by OEM. (z) One number wall mounted type telephone instrument of make Crompton Greaves / Beetel /OEM own make installed inside of car cabin along with fixing arrangement and telephone cable of suitable size from car cabin to machine room run along with trailing cable. The telephone instrument shall be connected in the telephone DB installed in the machine room. (za) One number electrically operated siren, operating voltage 240 volts having audible range of 0.5 Km of Make : KHERAJ Model No SS050 /OEM own make alongwith One Number inverter unit of suitable capacity but not less than 0.5KVA comprising of maintenance free battery connected with charging system including a separate switch/push button inside of car panel and electric wiring circuit upto the machine room. The siren shall be installed over the building at appropriate place and to be operated from inside the car. (zb) 5 W LED light Fixture (5 nos.) (zc) 250 mm sweep Fan (1 nos.) NOTE :- The contractor shall obtain necessary approval from local / state / Central Government Authority and make arrangement for inspection & test required. Contractor shall submit required certificate/license from competent authority before commissioning/ handing over or as directed by Engineer-in-charge

-

-

-

... More
SCH 'A' PART- XIV WORK (COMPREHENSIVE MAINTENANCE OF LIFTS AFTER SUCCESSFUL COMPLETION OF DEFECTS LIABILITY PERIOD)

-

-

-

... More
Comprehensive maintenance and repair of Passenger lift (02 numbers) having capacity 08 passengers (544 Kgs) as installed vide BOQ item No. 23.01 complete all as specified and directed.

-

-

-

... More
(i) First Year after expiry of defect liability period (i.e for 3rd year)

12

-

-

... More
(ii) Second Year after expiry of defect liability period (i.e for 4th year)

12

-

-

... More
(iii) Third Year after expiry of defect liability period (i.e for 5th year)

12

-

-

... More
Comprehensive maintenance and repair of Passenger lift (02 numbers) having capacity 13 passengers (884 Kgs) as installed vide BOQ item No. 23.06 complete all as specified and directed.

-

-

-

... More
(i) First Year after expiry of defect liability period (i.e for 3rd year)

12

-

-

... More
(ii) Second Year after expiry of defect liability period (i.e for 4th year)

12

-

-

... More
(iii) Third Year after expiry of defect liability period (i.e for 5th year)

12

-

-

... More
Notes for item Nos 15.01 to 15.08 :- (a) Contractor shall carryout comprehensive maintenance (routine, daily, weekly, monthly, quarterly, half yearly, yearly) as per Proforma Nos. 1 to 6 given in the contract and as per existing rules and regulations given by govt and department and maintain all the lifts in serviceable condition 24 Hrs x 365 days during Comprehensive maintenance period. (b) The Contractor shall carry out the Comprehensive maintenance of the Lifts through OEM only. (c) The Comprehensive maintenance should cover any/all parts of Lifts. If its functions found defective, the same should be repaired or replaced by the contractor through OEM as per the timeline covered under contract conditions. (d) One mechanics shall be deployed by contractor round the clock at lift complaint cell for safe & smooth functioning of all the lifts. Quoted rate shall be inclusive of this component. (e) Rewinding of motor, if required, will be done by the contractor and no extra cost will be given by the department on this account. (f) The lift mechanics deployed by contractor shall report to the Concerned JE at the Lift complaint cell for receiving the complaints round the clock daily including Sunday and holiday.

-

-

-

... More
(g) The lift mechanics deployed by contractor shall sign (their shift wise) in the attendance register kept at lift complaint cell. (h) Cost of minor spare parts/ routine material required during comprehensive maintenance of the lifts is deemed to be included in the quoted rate. No additional cost of spares is admissible to the contractor. Decision of the Accepting Officer shall be final & binding regarding minor spares/ routine material. (j) Monthly schedule for proper maintenance of lift and necessary documentation including all spare parts required to be replaced during the period shall be maintained as directed by Engineer-in-Charge. (k) Contractor shall submit license from Govt. of Maharashtra for maintenance & erection of lifts issued by Chief Electrical Inspector. (l) Appropriate penalty for not carrying out timely maintenance shall be levied as per contract conditions. Any third party damage due to malfunctioning of lifts shall be the sole responsibility of the contractor and the same shall be made good by contractor without any extra cost to the department. (m) Scope of Comprehensive maintenance shall cover the entire lift i.e. cabin, doors, control panel, drives, pulley, chain, battery, LED lights, COP, LOP, cables, main switches, Machine room lighting etc.

-

-

-



Evaluation Notes How It Works ?

Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.