Military Engineer Services Tender

... More
Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.

Military Engineer Services - MES Tender

Works
Civil And Construction
Eprocure
Opening Date14 Feb 2025
Closing Date5 Mar 2025
Tender Amount₹ 45,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm in any type of soil

80

-

-

... More
Returning, filling including spreading, leveling watering and well ramming in layers n.exc 25cm in hard/dense soil complete all as specified and directed by Engr-in-Charge..

70

-

-

... More
Removing excavated material to a distance n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and directed by Engr-in-Charge.

127

-

-

... More
M & L for plain cement concrete 1:3:6 type C2 as in bed to drain pipe, 300mm bore including packing under and haunching against the sides of pipes after they are laid and tested including necessary shuttering and supports to concrete

10

-

-

... More
M & L for plain cement concrete 1:3:6 type C2 as in bed to drain pipe, 200mm bore including packing under and haunching against the sides of pipes after they are laid and tested including necessary shuttering and supports to concrete

35

-

-

... More
M & L for plain cement concrete 1:3:6 type C2 as in bed to drain pipe, 150mm bore including packing under and haunching against the sides of pipes after they are laid and tested including necessary shuttering and supports to concrete

110

-

-

... More
M&L reinforced concrete pipe class NP 2 laid and jointed complete with collars 300 mm dia

10

-

-

... More
M&L reinforced concrete pipe class NP 2 laid and jointed complete with collars 200 mm dia

30

-

-

... More
M&L reinforced concrete pipe class NP 2 laid and jointed complete with collars 150 mm dia

100

-

-

... More
M&L in Repairs for 200mm internal dia sail glazed stone-ware drain pipe Grade'A' laid in trenches and jointed complete all as specified and directed.

5

-

-

... More
M&L in Repairs for 150mm internal dia sail glazed stone-ware drain pipe Grade'A' laid in trenches and jointed complete all as specified and directed.

10

-

-

... More
Labour for cleaning /clearing of blockage of gully traps, floor traps, vertical and horizontal soils/ waste pipe of different dia and sewage lines( PVC/SGW/ CI/RCC of any dia) except cleaning of manholes including opening inspection eye door of bend/ branch pieces, rodding till smooth flow and refixing of door after cleaning and any other cleaning work as directed by engr-in-charge in the area of the SPDC,NSD MANKHURD, WED MANKHURD under GE (NW) Mankhurd Note: (a) Contractor's labour will report daily at 0845 hrs on all working days at online complain cell centre and attend complaints given by Engr -In- Charge . Complaints needs to be cleared within 24 hrs after receiving the complaints . The contractor will deploy requisite labour and supply all T&P ( mechanical Iron rods, knot ropes , bamboo etc) scaffolding ladders and necessary safety measures such as gas mask, use of safety belt and cell torch etc and any other materials required to clear the blockages at the site without any extra cost . In case any labour does not report to Engineer In Charge for the whole day or found missing more than half an hour on any day, Panel recovery @ RS.860/- per head per day shall be made proportionally from contractor's dues. b) The above item includes conveyance cost of labour with their tools to travel from one area/location to other area/location to attend complaints, plugging of sewer and diverting flow of sewage if necessary to carry out the work and removal of sludge from the site to outside MOD land (The department shall not be liable to provide any kind/form of transportation to the labour). (c) Registers of labour attendance and complaints shall be maintained by contractor at their own cost,which shall be kept in the custody of MES Department(complaint cell) duly signed by contractor's representative ,JE(civil) and Engineer in charge.

166

-

-

... More
Cleaning manhole of size n.exc 1.50 Sqm by taking out sludge in semi liquid/solid stage (incl. all water etc) from inside of manhole of depth not exceeding 1.5 m and removing the sludge to a distance not exceeding 50m depositing in trenches including supply and sprinkling bleaching powder and covering sludge with earth to a thickness not less than 30 cm including all earth work, returning filling, removal of surplus soil & necessary temporary cleaning and necessary safety measures such as gas mask, use of safety belt etc as directed by the Engineer-in-Charge.

15

-

-

... More
Opening cover of manhole/septic tank exc 1.5 m depth, dewatering and pumping out night sludge etc from septic tank by mechanical means and removing sludge outside MD land and cleaning the septic tank as per BMC rules and placing the cover in original position taking all precautionary and safety measures all as directed. Note: All T&P and transportation for carrying sludge shall be provided by the contractor at their own cost.

5

-

-

... More
Demolition of brick work or stone masonary built in cement mortar including all quoins, arches, pillars etc. and M&L for brick work with subclass 'B' bricks straight or curved on plan exceeding 6mtr mean radius built in CM 1:6 complete all as specified.

6

-

-

... More
M & L for brick work with subclass 'B' bricks straight or curved on plan exceeding 6mm mean radius built in CM 1:6 complete all as specified.

4

-

-

... More
Demolition of brick work or stone masonary built in cement mortar including all quoins, arches, pillars etc.

69

-

-

... More
Taking down cement plaster of any description from brick or stone walls including raking out joints, hacking for key , scrubbing down with water etc complete all as specified

50

-

-

... More
M & L for rendering 15 mm thick using polymer modified ready mix cement based plaster on the wall surfaces including finishing the surface of top layer even and smooth complete all as specified and directed make: easyplast from wall plast/readiplast from ultratech. Note: The thickness of plaster specified above is minimum thickness and the quoted rates shall also deemd to be include for the provosion of dubbing of the surface and nothing extra shall be payable on this account. The rate also includes the rate of scaffolding and necessary safety measurements

150

-

-

... More
M&L rendering 15 mm thick on fair faces of brick or concrete surfaces in CM(1:6) finished even and fair.

100

-

-

... More
M&L for rendering 20mm thick in CM 1:4 as stone mansonry surfaces making surfaces fair & even without using extra cement.

332

-

-

... More
M&L for Preparing surfaces plastered or unplastered and applying applying Two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces.

50

-

-

... More
M & L cement concrete type B 1 1:2:4( 20 mm graded aggregate), in lintels upto 1.5 m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates/ blocks, water troughs and the like including weathering, slightly rounded for chamfered angles and throating, complete all as specified and directed

4.2

-

-

... More
M & L for precast reinforced cement concrete M-30 (20mm graded aggregates) Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like all as specified and directed. (Note :- Reinforcement shall be measured and paid separately).

6

-

-

... More
S & F for CRS deformed or twisted bars 10 mm dia and over, cut to length, bent to shape required including mild steel wire (annealed) not less than 0.9mm dia complete all as specified.

300

-

-

... More
M&L for plain cement concrete 1:3:6 (type C2), using 40mm graded stone aggregates mixed with water proofing compound @3% by weight of cement for fixing of nahani or floor traps, bedding in manholes, sunken floor complete all as specified and directed by the Engineer-in-charge Note: Water proofing compound shall be measured and paid separately

3

-

-

... More
M & L for cement concrete 1:3:6 , type C-1 (using 20mm graded stone aggregate) as in coping, bed block and similar works including necessary form work complete all as specified and directed

3

-

-

... More
M & L for cement concrete 1:3:6 , type C-2 (using 40mm graded stone aggregate) as in surface channels and drain complete all as specified and directed

3

-

-

... More
Supply only intergal water proofing compound. (ISI marked).

15

-

-

... More
M&L for 75 mm dia PVC (SWR) floor trap, plain with grating including jointing with solvent cement including removing the old one etc complete all as specified and directed.

50

-

-

... More
S & F PVC (SWR) gully trap in repairs 125/110 mm, setting and jointing with solvent cement complete all as specified.

18

-

-

... More
M & L for walling of random rubble masonary, uncoursed, well bonded, bedded and soildly hearted built in cm1:6 all as specified.

61

-

-

... More
----Ditto --- all as per item No 35.00 above but except stone.

4

-

-

... More
Extra over stone walling for hammer dressing to face stones and dressing of face beds and joints,as specified,of random rubble walling, with maximum depression on face from straight edge 20mm held against the dressed surface.

259

-

-

... More
M&L for flush pointing to random rubble uncoursed or brought up to course built in cement mortar 1:4 all as specified and directed

4

-

-

... More
M&L for raised pointing to random or polygonal rubble,uncoursed or bought upto course or bought upto courses in cement mortar 1:4 complete all as specified and directed

17

-

-

... More
M&L RCC M-30 for Bands, Beams, cantilevelers, bressummers, lintels over 1.5m span complete all as specified and directed

5

-

-

... More
Formwork to edges of concrete flats, breaks in floors, openings in concrete walls, floors & roofs & sides of RCC/PCC bands in walls, horizontal or sloping, & similar work all exceeding 20cm wide and sides of RCC/PCC bands in walls,horizontal or sloping complete all as specified and directed

22

-

-

... More
Demolition of cement concrete in ground floors and paving n.exc 15cm thickness (below or above ground level) and removing debris outside MD land complete all as specified and directed

37.5

-

-

... More
M&L for 75mm thick Cement concrete in C1 type (1:3:6) using 40mm graded stone aggregate as in plinth protection and finished even and smooth with using extra cement as specified and directed

150

-

-

... More
M&L PCC 1:3:6 type C2 (40mm graded aggregate)75mm thick as in sub base/flooring Finishing cement concrete surface even and smooth all as specified and directed

300

-

-

... More
M&L Precast cement concrete cover slabs 75mm thick and Crossectional area exc 0.36 Sqm and n.exc 0.5 Sqm each for drain cover and similar work with plain faces set in cement mortar 1:6 complete all as speicified and directed.

5

-

-

... More
M & L for hardcore with broken stone or boulders of gauge n exc.63mm, deposited, spread & levelled in layers n exc 15cm thick, watered & rammed to a true surface

42.5

-

-

... More
M&L for Machine pressed precast coloured concrete interlocking 60mm thick precast cement grade M-35 with grey cement and pigment having compresive strength 35 N/mm2 laid with over sand cushinig after consolitation set and level the tiles on proper level with interlocking complete all as specified and directed. Note Sand Cushoining will be measured and paid seperately under relevant item

300

-

-

... More
M&L for cement concrete 1:4:8 Type D-2 75 mm thick(Using 40mm Graded Aggregate) as in sub base etc,finishing surface even and rough using broom finish complete all as specified and directed

50

-

-

... More
Dismantling of wrought iron of mild steel work of any description not otherwise poivided

5

-

-

... More
Dismantling fencing wire mesh chain link fencing etc, any type all as specified and directed

265

-

-

... More
Dismantling of posts or struts ( steel ) of any section including taking out embedded portion from natural ground and making good disturbed ground complete.

120

-

-

... More
S&F in repais galvanised ,2 srand steel barbed wire 2.24mm dia barbed with 2mm dia barsbs n exc 150mm spacing and staining rail staining bolts incl, securing or tying at crossing with and provision of galvanised mild steeled wire staples or steel pins etc as directed (each line wire to be measured) all as specifed and directed

7.5

-

-

... More
S&F framed work as in door or gates of angles or other section with gueset plates, rails, braces etc. complete all drilled for fixing of steel sheeting or other covering doors etc.to be prepared for hanging for sliding with hooks and pintel hinges and fasteing commplete all as specified and directed.

100

-

-

... More
M&L Mild steel bars CRS TMT bars 10mm dia & over, cut to length bent to shape required, including cranking, bending spirally for hoping for columns, hooking ends & binding with & including mild steel wire (annealed) not less than 0.9mm dia or securing with clips all as specified and directed.

37.5

-

-

... More
M&L Same as per Item no 54.00 above , but 5mm dia & over upto & including 10cm dia in stirrups, spacers & binders of TMT bars.

60

-

-

... More
S&F M.S post and struts in fencing, joist, channel, angle or tee for posts,truss, support for sheeting ets cutting tops to shape as directed drilling holes notching for wire etc including bolts complete as specified.

400

-

-

... More
M&L for preparing of new steel surfaces of applying two coat of sythetic enemul paint over one coat of red oxide any description over 10cm in width or girth not otherwise described all as specified and directed.

104.5

-

-

... More
ditto - -all as per item No 57.00 above but one coat of synthetic enamel paint on existing steel surface including preparation of surfaces.

10

-

-

... More
S & F barbed razor tape concertina coil SG hot galvanized spring tensile wire to particular here-in-after or other equivalent make as approved by GE of UTS 145 to 150 kg/mm^2 and Dia of coil when unstreched 601mm having minimum number of circles 10/Rm,minimum number of clipes 25/RM and minimum weight of coil 1.625 Kg/Rm,hot dip galvanized razor ribbon tape of size 0.50mm thickness,19 mm width before wrapping on central core wire fixed with GI 1.66 mm clips and special nut bolts to hold two coils together and extra 2 rows parallel wire of 10 gauge tied by binding wire whreever complete all as specified and directed by engineer -in-charge

177.5

-

-

... More
M & L for broken glass coping on top of walls in CM 1:3, 25 mm thick using 10 Kg broken glass per Sqm all as specified.

3

-

-

... More
Framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forget into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 290 Gde E 165

300

-

-

... More
M&L for treating with tar or coal tar black paint on ends of posts area exc 0.10 Sqm but not exc 0.5 Sqm each complete all as specified.

40

-

-

... More
M&L for demolition of reinforced cement concrete in roofs, floors, beams, staircases, landings, chajjas and similar suspended work (reinforcement cut to facilitate demolition) including scaffolding and necessary safety arrangements, all as specified

0.1

-

-

... More
Taking down cement or cement lime plaster on brick or stone walls etc including raking out joints, hacking for keys, scrubbing down with water complete, and material & labour for 15mm thick in two coats (10+5mm) polymer modified ready mix cement based plaster on the wall surfaces complete all as specified and directed make: easyplast from wall plast/readiplast from ultratech including material and labour for preparation for applying two coats of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resisitance as per IS 15489:2004, alkali & fungal rsistance, dirt resistance exterior paint of required shades(Company Depot Tinted) with silicon additives @ 1.43 litre/10sqm over & including priming coat of extreior primer applied @ 0.90 litre/10 sqm including exterior wall care putty over new surfaces Note: The thickness of plaster specified above is minimum thickness and the quoted rates shall also deemd to be include for the provosion of dubbing of the surface and nothing extra shall be payable on this account.and applying all as specified including necessary scaffolding and safety arrangement

300

-

-

... More
Taking down cement or cement lime plaster on brick or stone walls etc including raking out joints, hacking for keys, scrubbing down with water complete, and material & labour for 10mm thick polymer modified ready mix cement based plaster on the wall surfaces complete all as specified and directed make: easyplast from wall plast/readiplast from ultratech including material and labour for preparation of new plastered surfaces on walls, preparation for distempering and applying two coat of oilbound distemper over a coat of primer including stopping of nails holes,cracks etc and 1 mm thick (minimum) white cement based wall care putty on new surfaces of walls etc, finished even and smooth, complete all as specified and directed. Note: The thickness of plaster specified above is minimum thickness and the quoted rates shall also deemd to be include for the provosion of dubbing of the surface and nothing extra shall be payable on this account.and applying all as specified including necessary scaffolding and safety arrangement

250

-

-

... More
Taking down cement or cement lime plaster on concrete surfaces etc including raking out joints, hacking for keys, scrubbing down with water complete, and material & labour for 5mm thick polymer modified ready mix cement based plaster on the ceiling surfaces complete all as specified and directed make: easyplast from wall plast/readiplast from ultratech including material and labour Preparation of new plastered surfaces on ceiling and applying three coat of white wash complete all as specified. and directed. Note: The thickness of plaster specified above is minimum thickness and the quoted rates shall also deemd to be include for the provosion of dubbing of the surface and nothing extra shall be payable on this account.and applying all as specified including necessary scaffolding and safety arrangement

200

-

-

... More
M&L for repairs to walls of Underground Sump/ water tank of any depth of max 4mtrs including scaffolding and safety arrangements completely all as specified and as directed by Engineer in Charge in following steps as mentioned below 1. Surface preparation: Empty the water from water tank followed by removing the old plasters to expose the bare concrete, the damaged concrete to be repaired with polymer modified cement-sand mortar with SBR Latex, filling all cracks with polymer modified mortar using SBR Latex. Cleaning and preparation of surface with the help of wire brush or grinder . 2. Grouting Pipe inserts: Wrapping all pipes inserts with a two way adhesion tape of make Dr. Fixit Bathseal tape and grouting the gaps space with non- shrink grout Dr. Fixit Pidigrout 10M or PMM prepared by polymer modified mortar with Dr. Fixit Pidicrete URP in the ratio of 1:3 by adding polymer 10% by weight of the cement. 3. Injection Treatment: Providing and fixing PVC grouting nozzles of 130mm length & 10mm outer dia, with a stopper at the outer end, shall be fixed on the concrete surface @ 1m C/C or at the particular location of water leakage, by drilling a hole of same dia and inserting up to a depth of 80mm. Cement paste mixed with Dr. Fixit Instant leak Plug shall be used to fix and seal the sides of the nozzle.The Grout shall be prepared with mix of cement & Dr. Fixit Pidicrete AM expansive grouting additive in W/C ratio not morethan 0.45. The grouting shall be done under pressure of 3 kg / cm2 using grouting pump. 4.Angel Fillet: All the old/broken joints needs to be removed and provided with 50 mm X 50 mm angle fillets on the vertical up- stands, parapet wall junction corners, service units and properly dressed by preparing polymer modified mortar with Dr. Fixit Pidicrete URP in the ratio of 1:3 by adding polymer 10% by weight of the cement. 5.Waterproof Coating: Providing & Applying 2 coats of CFTRI approved, waterproof coating with high performance two component pre-packed cementitious waterproofing, Dr. Fixit Fastflex, with a mix ratio of (liquid: Powder), parts by wt. - 1:1.4 @ 0.42 – 0.50 Sq.mt / Kg to achieve 1mm DFT over the floor surface & wall surface upto full height, as per the manufacturer’s specification. All the coats to be applied in right angle to each other with an interval of 4-6 Hrs, including proper surface preparation as per manufacturers' specification, cleaning work, removal of loose concrete and filling cracks with polymer modified mortar using SBR Latex, Dr. Fixit Pidicrete URP. All the honeycombed areas & construction joints shall be identified and injected with cement slurry admixed with expansive additive, Dr. Fixit Pidicrete AM @ 225gms / bag of cement. Provide and lay 45 GSM glass fibre mesh over the angle fillet when the first coat in still wet. Sprinkle the quartz sand / fine sand over the final coat when it is still wet on the vertical wall surface for creating a firm key for plastering to ensure complete waterproofing. Allow the coating to air cure for 5 days before conducting water ponding test for 24 Hrs. The coating shall have Elongation at break 120% as per ASTM D 412, Tensile strength 1 N /mm2 as per ASTM D 412, Adhesion strength : 0.80 N/mm2 as per ASTM D 4541, crack bridging upto 2mm as per ASTM C 836, Water penetration (5 bar pressure) : 1% as per BS EN 12390. 6. Protection Plaster / Screed: Providing & laying 20-25mm THK protective plaster / Screed of C:M in the ratio of 1:4 admixed with integral waterproof compound conforming to IS 2645:2003, Dr. Fixit Pidiproof LW+ @ 200ml per bag of cement, over the waterproofing membrane for vertical & horizontal protection. 7.Hygiene coat: Anti-microbial Coating.:Providing & applying 2 coats of Dr. Fixit Dampguard Classic – two component, water-based epoxy resin having anti-algae, antifungal, Non-toxic, hygiene cum damp-proof coating Certified by CFTRI as per 21 CFR 175 – 300 of US – FDA, having mixing Ratio (Base: Hardener: Water) – 1:1:1 to be applied @ 4 sqm / Kg, as per manufacturer's specification. The coating shall have Specific Gravity: 1.2, Water vapor permeance: 244.48 g/m2/24 hrs, as per IS 7809/Pt 2/1977, Adhesion strength: 2 N/mm2 as per ASTM D 4541: 02, all as per manufacturers' specification, etc, complete. Note :- Complete treatment has to be done by Manufacturers applicator itself, Manufacturers applicator should be submitted before commencement of work and Guarantees Certificate for 5 years should be submitted of Manufacturer.

250

-

-

... More
M&L for repairs to Floors of Underground Sump/ water tank of any depth of max 4mtrs including scaffolding and safety arrangements completely all as specified and as directed by Engineer in Charge in following steps as mentioned below 1. Surface preparation: Empty the water from water tank followed by removing the old plasters to expose the bare concrete, the damaged concrete to be repaired with polymer modified cement-sand mortar with SBR Latex, filling all cracks with polymer modified mortar using SBR Latex. Cleaning and preparation of surface with the help of wire brush or grinder . 2. Grouting Pipe inserts: Wrapping all pipes inserts with a two way adhesion tape of make Dr. Fixit Bathseal tape and grouting the gaps space with non- shrink grout Dr. Fixit Pidigrout 10M or PMM prepared by polymer modified mortar with Dr. Fixit Pidicrete URP in the ratio of 1:3 by adding polymer 10% by weight of the cement. 3. Injection Treatment: Providing and fixing PVC grouting nozzles of 130mm length & 10mm outer dia, with a stopper at the outer end, shall be fixed on the concrete surface @ 1m C/C or at the particular location of water leakage, by drilling a hole of same dia and inserting up to a depth of 80mm. Cement paste mixed with Dr. Fixit Instant leak Plug shall be used to fix and seal the sides of the nozzle.The Grout shall be prepared with mix of cement & Dr. Fixit Pidicrete AM expansive grouting additive in W/C ratio not morethan 0.45. The grouting shall be done under pressure of 3 kg / cm2 using grouting pump. 4.Angel Fillet: All the old/broken joints needs to be removed and provided with 50 mm X 50 mm angle fillets on the vertical up- stands, parapet wall junction corners, service units and properly dressed by preparing polymer modified mortar with Dr. Fixit Pidicrete URP in the ratio of 1:3 by adding polymer 10% by weight of the cement. 5.Waterproof Coating: Providing & Applying 2 coats of CFTRI approved, waterproof coating with high performance two component pre-packed cementitious waterproofing, Dr. Fixit Fastflex, with a mix ratio of (liquid: Powder), parts by wt. - 1:1.4 @ 0.42 – 0.50 Sq.mt / Kg to achieve 1mm DFT over the floor surface & wall surface upto full height, as per the manufacturer’s specification. All the coats to be applied in right angle to each other with an interval of 4-6 Hrs, including proper surface preparation as per manufacturers' specification, cleaning work, removal of loose concrete and filling cracks with polymer modified mortar using SBR Latex, Dr. Fixit Pidicrete URP. All the honeycombed areas & construction joints shall be identified and injected with cement slurry admixed with expansive additive, Dr. Fixit Pidicrete AM @ 225gms / bag of cement. Provide and lay 45 GSM glass fibre mesh over the angle fillet when the first coat in still wet. Sprinkle the quartz sand / fine sand over the final coat when it is still wet on the vertical wall surface for creating a firm key for plastering to ensure complete waterproofing. Allow the coating to air cure for 5 days before conducting water ponding test for 24 Hrs. The coating shall have Elongation at break 120% as per ASTM D 412, Tensile strength 1 N /mm2 as per ASTM D 412, Adhesion strength : 0.80 N/mm2 as per ASTM D 4541, crack bridging upto 2mm as per ASTM C 836, Water penetration (5 bar pressure) : 1% as per BS EN 12390. 6. Horizontal Protection & Slope: Providing & laying 75mm THK protective screed of Cement Concrete of 1:1.5:3 mix admixed with integral compound conforming to IS 2645:2003, Pidiproof LW+ @ 220ml per bag of cement, to provide slope to the horizontal surface towards drain outlet and also to protect the waterproofing, keeping the surface broomed, curing and testing for water tightness for 7 days etc. complete 7. Protection Plaster / Screed: Providing & laying 20-25mm THK protective plaster / Screed of C:M in the ratio of 1:4 admixed with integral waterproof compound conforming to IS 2645:2003, Dr. Fixit Pidiproof LW+ @ 200ml per bag of cement, over the waterproofing membrane for vertical & horizontal protection. 8.Hygiene coat: Anti-microbial Coating.:Providing & applying 2 coats of Dr. Fixit Dampguard Classic – two component, water-based epoxy resin having anti-algae, antifungal, Non-toxic, hygiene cum damp-proof coating Certified by CFTRI as per 21 CFR 175 – 300 of US – FDA, having mixing Ratio (Base: Hardener: Water) – 1:1:1 to be applied @ 4 sqm / Kg, as per manufacturer's specification. The coating shall have Specific Gravity: 1.2, Water vapor permeance: 244.48 g/m2/24 hrs, as per IS 7809/Pt 2/1977, Adhesion strength: 2 N/mm2 as per ASTM D 4541: 02, all as per manufacturers' specification, etc, complete. Note :- Complete treatment has to be done by Manufacturers applicator itself, Manufacturers applicator should be submitted before commencement of work and Guarantees Certificate for 5 years should be submitted of Manufacturer.

100

-

-

... More
M&L for structural repairs to Columns,beams and slabs and chajja at maximum height of 8mtrs including scaffolding and safety arrangements completely all as specified and as directed by Engineer in Charge in following steps as mentioned below 1) Chipping , Removing,Carefullly Loose Concrete work by low impact Hammer/Breakar without damaging the structure & cleaning and disposal of malba out side the premises etc. complete as directed. Hard concrete should not be removed by force. 2) M&L for cleaning existing reinforcement with wire/ rotary wire brush to a shining bright finish, making the surfaces free from loose material, dirt etc complete and applying two coats of alkaline rust converting primer conforming to ASTM-B-117 of make. "Feovert" of "Krishna Conchem" OR "Roff Rust Cleaner' of 'Pidilite' OR 'Shali Rustoff' of 'STP Ltd', on rebars with time interval of 1 hr between the coats, complete all as specified and directed. (Note :- Mode of measurement: superficial area of concrete will be measured.) 3)M&L for Anticorrosive Treatment to Reinforcement using Corroseal - ZR of M/s Krishna Conchem or Epoxy Zinc Primer of M/s. Dr. Fixit by application on exposed reinforcement in two coats with time interval of minimum 4 hours between each coat. The application shall be done by brush after cleaning/wire brushing to the exposed steel surfaces, complete all as specified and directed. 4) M&L for Epoxy bond coat of Make Fosroc (NITOBOND-EP) OR EPOXY BONDING AGENT of Dr. Fixit OR equivalent of M/s. Krishna Conchem as approved by GE over exposed concrete surfaces prior to application of any type of mortar to ensure bond between old concrete & new concrete by brush application, complete all as specified and directed. 5) M&L for building up the profile of structural members by using polymer modified mortar from M/s. Krishna Conchem (Molith-PMM) OR Polymer mortar HB of Dr Fixit upto 40mm thickness including levelling, profiling etc in two layers, each layer not exceeding 20mm, complete all as specified and directed. 6) M&L for 15mm thick in two coats (10+5mm) polymer modified ready mix cement based plaster on the wall surfaces complete all as specified and directed make: easyplast from wall plast/readiplast from ultratech including material and labour for preparation for applying two coats of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resisitance as per IS 15489:2004, alkali & fungal rsistance, dirt resistance exterior paint of required shades(Company Depot Tinted) with silicon additives @ 1.43 litre/10sqm over & including priming coat of extreior primer applied @ 0.90 litre/10 sqm over new surfaces

20

-

-

... More
All as per item 69.00 above but Providing 10mm thick polymer modified ready mix cement based plaster on the wall surfaces complete all as specified and directed make: easyplast from wall plast/readiplast from ultratech including material and labour for preparation of new plastered surfaces on walls, preparation for distempering and applying two coat of oilbound distemper over a coat of primer including stopping of nails holes,cracks etc and 1 mm thick (minimum) white cement based wall care putty on new surfaces of walls etc, finished even and smooth, complete all as specified and directed.

20

-

-

... More
All as per item 69.00 above but providing for 5mm thick polymer modified ready mix cement based plaster on the ceiling surfaces complete all as specified and directed make: easyplast from wall plast/readiplast from ultratech including Preparation of new plastered surfaces and applying three coat of white wash on surfaces complete all as specified.

20

-

-

... More
Providing and fixing additional steel bar in various structural elements like column ,beams and Slab etc. including drilling ,bending and fixing the bars tying with preleft binding wires etc.

50

-

-

... More
S&F in repairs Pre-painted Corrugated galvalume sheet having aluminium zinc coating with hot dip alloy of 55% Aluminium 43.5% Zinc 1.5% Silicon and finished with resin coat on both surfaces @ 150 gm/sqm of coating (total both surfaces) having overall width and laid width as specified GI based corrugated steel sheet 0.5mm thick of any colour having tensile strength of 550 Mpa as in roof covering /cladding to wall, fixed with fixed using hot dip galvanized, self drilling and self tapping screws neoprene and EPDM washers. Penetrations and laps in sheet shall be sealed by using proper sealant profile. HDPE fillers shall be provided wherever required to close voids between sheets, sheet & fasteners including dismatling of old sheet of any type etc. completely all as specified and as directed. upto maximum height of 12 Mtr

100

-

-

... More
S&F in repairs Pre-painted Plain galvalume sheet having aluminium zinc coating with hot dip alloy of 55% Aluminium 43.5% Zinc 1.5% Silicon and finished with resin coat on both surfaces @ 150 gm/sqm of coating (total both surfaces) having overall width and laid width as specified GI based plain steel sheet 0.5mm thick of any colour having tensile strength of 550 Mpa as in roof covering /cladding to wall, fixed with fixed using hot dip galvanized, self drilling and self tapping screws neoprene and EPDM washers. Penetrations and laps in sheet shall be sealed by using proper sealant profile. HDPE fillers shall be provided wherever required to close voids between sheets, sheet & fasteners including dismatling of old sheet of any type etc. completely all as specified and as directed. upto maximum height of 12 Mtr

29

-

-

... More
S & F in repairs Steel work in tubular /Rectangular hollow section in trusses, Posts, Purlins, Rafters etc including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS 1161-1979 grade St.-240

200

-

-

... More
S & F in repairs Steel work Fe 410 F23-W (Gde- E- 250) quality-A in plates or gusset plates to truss all as specified and directed

28

-

-

... More
Taking down rolling shutters area n.exc 10 sqm each and re-fixing to its original position after cleaning all parts, straightening rails, changing damaged strips, bottom rail,guide rail, helical spring worm gear, lock plate, ball bearings, Top sheet, Gear box and locking arrangements etc as required, greasing, oiling, servicing for smooth functioning of all parts complete all as directed including all spare parts and gear box and completely painting with one coat of primer and two coats of sythetic enamel paint complete all as specified and as directed by Engineer in Charge.. Note: No extra Payments against any item will be paid and deemed to be included in Job, and Size of Opening will be considered for shutter size, Scaffolding if required is deemed to be included in Job

8

-

-

... More
Taking down Asbestos Cement gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including removal out of MD land (measured overall as fixed along the centre line over fittings and accessories) at the height of 8 Mtr and M&L for providing 160mm PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls Or Pillars etc including scaffolding if required,

20

-

-

... More
M&L for providing 160mm PVC (SWR) 45 degree Shoe bend with rubber ring joints fixed to walls Or Pillars etc

10

-

-

... More
M&L for Providing waterproofing treatment as specified below and at any height of roof surface including removal of watertank, plumbing line during waterproofing making good if any holes and refixing the same as directed by Accepting officer and Engineer in charge complete 1) Dismantling completely existing roof treatment (excluding cement screed bed ) including loosened cement plaster and exposing the top surface of RCC slab and making good the same in CM 1:4 and removing rubbish, etc outside MD land complete all as specified and directed by the Engineer-in-charge 2) M&L for averaging 50 mm thick PCC 1:2:4, type -B-1, using 20mm graded stone aggregated as in padding concrete of roof mixed with WPC in the proportion as recommanded by the manufacturer(s), including demolition of old concrete complete all as specified and directed, 3) M&L 10 mm thick Screed bed or bedding layer in CM (1:3) with WPC when the concrete is still green complete all as specified and directed. 4) M & L for APP modified roof treatment over existing roof slab etc to be executed through approved authorised applicator of the membrane manufacturer with the following specifications complete all as specified and directed:- (a). The roof surface shall be throughly wire brushed cleaned to eliminate all sharp projection, washed dried upto and cleaned overall foreign material and dust to receive primer. (b). The dry surface shall be primed with Torch shield primer as per manufacturer’s instructions, manufactured by the same agency as that of APP membrane. (c). Providing and laying APP modified polyester reinforced water proofing membrane with minimum weight of 3.5 Kg/Sqm, as specified here-in-before. (d). The APP membrane shall be laid using torch-on butane application with minimum 10 cm side overlap and 15 cm end overlap. The laying of membrane shall be got done through an authorised applicator of manufacturer of the membrane. (e). The APP membrane shall be taken up to minimum 200 mm on vertical surfaces. The edge of the membrane shall be fixed with termination bar and fasteners and end shall be properly sealed with sealant.

220

-

-

... More
Disconnecting existing water storage tanks upto and including 1000 litres, setting aside (or lowering if required) for repairs to roof below, and replacing (or hoisting if required), re-fixing in position and re-connecting on completion of roof work complete all as specified and directed by the Engineer-in-charge for the following capacities:

2

-

-

... More
M&L for Demolition of stone slab and tiles of any size and description or thickness in floors laid bedded and pointed in any mortar including screed bed. and providing Machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete and other similar situations including Screed bed or bedding layer or mortar 20mm thick for laying floor finishes in CM 1:6 complete all as specified and directed.

30

-

-

... More
M&L for Demolition of stone slab and tiles of any size and description or thickness in floors laid bedded and pointed in any mortar including screed bed. and providing coloured 450x300x6mm thick glazed ceramic tiles on vertical surfaces such as skirting,dado etc, set and jointed in neat cement slurry and pointed in white cement mixed with pigment to match with the colour of tiles, over and including 10mm thick cement mortar backing coat in CM 1:4, complete all as specified and directed.

30

-

-

... More
M&L for Demolition of stone slab and tiles of any size and description or thickness in floors laid bedded and pointed in any mortar including screed bed. and providing coloured Non-skid ceramic tiles 7 to 8 mm thick (square/ rectangular) of approved size, area of each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm in floors etc, set and jointed in neat cement slurry and pointed in white cement mixed with pigment to match with nthe colour of tiles, over and including 15mm thick cement mortar screed bed in CM 1:6, complete all as specified and directed.

10

-

-

... More
Taking down chowkats or frames, not exc 4 Sqm each with wooden/ flush/ PVC /aluminium shutters (Without taking off shutters from the frame) including taking down of hold-fasts by cutting/chasing etc from existing surfaces and also taking down of grills (where exists), complete all as specified and directed and S&F standard aluminium section powder coated (minimum thickness of powder coating shall be 50 micron and colour shall be as approved by GE ) as in frame, shutters for doors, window / ventilators, partitions, fixed / openable / sliding or in any pattern, cut to size, jointed with cadmium plated steel screws, including rubber beading or gaskets for fixing glass, provision of hinges, screws, plugs, handle, lock, roller, Nylon ball bearing etc complete all as specified and directed (Aluminium section shall be of make Jindal/Hindalco/ Indalco) Note:- Weight of Aluminium sections as per actual or as per IS or as per manufacturer, whichever is less, shall only be considered for payment. Cost of other items / accessories required for entire completion of the work shall be deemed to be included in the quoted rate. However glass panes and wire cloth shall be measured and paid separately as supply only under respective items.

50

-

-

... More
Taking down chowkats or frames, not exc 2 Sqm each with wooden/ flush/ PVC /aluminium shutters (Without taking off shutters from the frame) including taking down of hold-fasts by cutting/chasing etc from existing surfaces and providing Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 45 x 70 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately). including providing Factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of 30mm size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant.WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In-Charge. Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall beacceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. WPC frame should be matching with shutter and any type of laminate approved by accepting officer is deemed to be included in the qouted rate Size of shutter for each frame will only be considered for mode of measurement.

10

-

-

... More
Taking down chowkats or frames, not exc 4 Sqm each with wooden/ flush/ PVC /aluminium shutters (Without taking off shutters from the frame) including taking down of hold-fasts by cutting/chasing etc from existing surfaces and providing Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 50 x 100 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately). including providing Factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of 30mm size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant.WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In-Charge. Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. WPC frame should be matching with shutter and any type of laminate approved by accepting officer is deemed to be included in the qouted rate Size of shutter for each frame will only be considered for mode of measurement.

10

-

-

... More
S&F in repairs aluminium anodised Grills of approved design for window / Bolcony ventilators and fixing with F/U channel for window, ventilators, balcony openging in architectual or rectangular type in existing building with C.P. brass/ stainless steel screws @ 200 mm centre to centre, , including drilling as required in RCC sections, complete all as specified and directed. Note: The Grills shall be of Model DG-102/DG-104 of Make Deco or equivalent make as approved by the GE.

20

-

-

... More
M&L for 4.8mm thick Sheet glass, ordinary quality and glazing with oil putty/rubber beading in square/rectangular size as required in each pane for Partition/Door/Window/Ventilator and similar works etc.

10

-

-

... More
Supply and fixing in repairs stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples

10

-

-

... More
Supply only stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples

10

-

-

... More
M&Lfor Granite (of any tpe), fixed in repairs 20 mm work (table rubbed and polished) in steps, jambs, pillars, windowcills,cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite

5

-

-

... More
M&L Rounding to edges of stone slabs of Granite or Green Marble of any thickness one edge such as in steps (Bull nosed) or Half round in cooking platform,and other similar situations completely all as specified and as directed by Engineer in Charge.

20

-

-

... More
S&Faluminium alloy, anodised, sliding door bolt with hasp, staple ( bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast- aluminium alloy and fixedd nuts, four on bolt plate and two on staple plate and fixed,300mm complete. fixed in repairs

10

-

-

... More
S&F aluminium, anodised, barrel tower bolts of extruded section and fixed 150 mm fixed in repairs

20

-

-

... More
S&F Stainless butt hinges with brass screws, size 100mm fixed in repairs

30

-

-

... More
S&F extruded aluminium alloy handles, fabricated type., anodised,150 mm fixed in repairs

20

-

-

... More
S&F in repairs vitreous China wash basin white, flat back size 550 x 400mm including 15mm dia fancy type pillar tap of Make ESSCO Model no DLX-507KN or equivalent of make Parko as approved by the GE, , chromium plated CP waste coupling, chain and plug, waste fitting, union and waste pipe 32mm dia of required length and all necessary 450mm long outlet and inlet PVC connections pipes with PTMT check nuts complete.

4

-

-

... More
S&F in repairs vitreous china urinal half stall type (back or corner wall type ), complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2 securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement with discharge pipe etc complete all as specified and as directed by Engineer In Charge.

1

-

-

... More
S&F in repairs vitreous coloured China Europeon water closet (Pedestal Pattern) including 10 ltr capacity low level flushing cistern with necessary PVC connections 15mm size with PTMT nuts of length 450mm long etc complete. Jaquar Essco Model No of EWC - ECS-WHT-551SNPP183LZ or ECS-WHT-551PNPP183LZ

4

-

-

... More
M&L for fixed in repairs 15 mm dia Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified , Cat No 187 of Prayag or equivalent make as approved by the GE complete all as speicified

2

-

-

... More
S&F fixed in repairs Two way Bib cock with flange 15mm dia Model no DLX-512ANKN of ESSCO or equivalent of MarC ,Parko as approved by the GE complete all as specified and directed.

2

-

-

... More
S&F fixed in repairs 15mm bore brass CP Stop Cock, Make ESSCO Model no DLX-526NKN or equivalent of make Parko as approved by the GE, complete all as specified and directed.

5

-

-

... More
S&F fixed in repairs 15mm bore brass CP Bib Tap, Make ESSCO Model no DLX-511KN or equivalent of make parko as approved by the GE, complete all as specified and directed.

5

-

-

... More
S&F in repairs brass chromium plated, shower rose, 125mm size with and including 195mm long 15mm bore brass chromium plated shower arm with bend of 45 degree, complete all as specified and directed.

1

-

-

... More
Supplying and laying in repairs against any dia GI tubing of 16mm Outer dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified, complete all as specified and as directed.

25

-

-

... More
Supplying and laying in repairs against any dia GI tubing of 20mm Outer dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified, complete all as specified and as directed.

25

-

-

... More
Supplying and laying in repairs against any dia GI tubing of 25mm Outer dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified, complete all as specified and as directed.

25

-

-

... More
M&L for PVC (SWR) pipes fixed in repairs single socketed in any length with rubber ring joints laid in trenches or floors 110 dia.

16

-

-

... More
M&L for PVC (SWR) pipes fixed in repairs single socketed in any length with rubber ring joints laid in trenches or floors but 75mm dia

16

-

-

... More
M&L PVC (SWR) pipes fixed in repairs single socketed in any length with rafter joints fixed to wall of 110mm dia

24

-

-

... More
M&L PVC (SWR) pipes fixed in repairs single socketed in any length with rafter joints fixed to wall of 75mm dia

24

-

-

... More
M&L for PVC (SWR) bends fixed in repairs any radius of 110mm dia

8

-

-

... More
M&L for PVC (SWR) bends fixed in repairs any radius of 75mm dia

8

-

-

... More
M&L for PVC (SWR) bends fixed in repairs any radius of 110mm dia provided with or without access door

8

-

-

... More
M&L for PVC (SWR) bends fixed in repairs any radius of 75mm dia provided with or without access door

8

-

-

... More
M&L PVC (SWR) Junction single, fixed in repairs (Single T) equal or unequal of 110mm dia bore provided with or without access door

8

-

-

... More
M&L PVC (SWR) Junction single, fixed in repairs (Single T) equal or unequal of 75mm dia bore provided with or without access door

8

-

-

... More
M&L for PVC (SWR) fixed in repairs vent cowl of 110mm dia

2

-

-

... More
M&L for PVC (SWR) fixed in repairs vent cowl of 75mm dia

2

-

-

... More
Cutting into existing manhole for connecting new drains making good to pipe and rendering cutting out existing benching for and forming channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B1 smooth finished and reforming benching as required internal dia of pipe 150mm maximum

2

-

-

... More
S&F in repairs rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I capacity 1000 Ltr complete fixed to pipe etc all as directed

2

-

-

... More
S&F in repairs ball brass valves high pressure with polyuthene float valve and fly nutcomplete screwed for iron pipe or brass ferrule and fiexed in repairsFloat valve 20mm

2

-

-

... More
S&F in repairs Gun metal globe or gate valve with iron wheel head screwed both ends for iron pipe and fixed in repairs 20mm bore

2

-

-

... More
Demoliton of Brickwork, precast cement concret block masonary ,built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles

10

-

-

... More
M&L Pre-cast cement concrete block masonry with solid blocks, exc. 10 cm in width and setting CM 1:6 in mortar ,Type B1,1:3:6,(20mm graded aggregate) complete all as specified and directed.

10

-

-

... More
M & L for PCC 1:4:8 type D2(using 40mm graded stone aggregate) in foundations, filling and mass concrete complete.

10

-

-

... More
S&F Hand rails, half round or other stock section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embedding in concrete and screwing etc. wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe 410-0 or Fe 310-0 Completely all as specified and as directed by Engineer in Charge

700

-

-

... More
Supply only PVC coated (1mm thick) chain link fencing exc 2.00 but n.exc 3.00 kg per sqm with size of mesh 50 x 50 mm and thickness of wire n.exc 2.83 mm all as specified and as directed.

694

-

-

... More
Fixing only PVC coated chain link fencing including fixing of line wires any mesh, size and any type of standards, rails, straining bolts etc including provision of binding wires complete.(Supply of MS line wire and flat iron bolt & nuts measured and paid seperately)

250

-

-

... More
Supply only 6mm dia wire PVC coated for support/line wire to chain link fencing complete.

80

-

-

... More
Supply only mild steel bolts with hexagonal or square head one end and screwed the other or screwed both ends each screwed end to be fitted with washers and one hexagonal or square nut exc 10 cm long n.exc 15 cm long dia metre of neck exceeding 11 to 15 mm complete.

100

-

-

... More
30mm thick Sand filling under floors including watering and consolidation as an Sand Cushoining under interlocking tiles.

7.5

-

-

... More
M&L for Filleting in any position and to any shape in in cement mortar 1:3 including all mitres, stops, etc.Exc. 25 but n .exc. 50 sq. cm

70

-

-

... More
Preparation of old surfaces on walls (plastered or unplastered or previously white washed) and applying one coat of white wash complete all as specified.

500

-

-

... More
Preparation of old surfaces on walls (plastered or unplastered or previously colour washed) and applying one coat of Colour wash complete all as specified.

500

-

-

... More
Preparation of old surfaces on ceiling (plastered or unplastered or previously white washed) and applying one coat of white wash complete all as specified.

250

-

-

... More
Preparation of old surfaces on ceiling. (plastered or unplastered or previously colour washed) and applying one coat of Colour wash complete all as specified.

60

-

-

... More
M & L for complete removal of existing treatement preparation for applying two coats of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resisitance as per IS 15489:2004, alkali & fungal rsistance, dirt resistance exterior paint of required shades(Company Depot Tinted) with silicon additives @ 1.43 litre/10sqm over & including priming coat of extreior primer applied @ 0.90 litre/10 sqm including exterior wall care putty of minimum 1mm thickness over surfaces

510

-

-

... More
M&L for complete removal of existing treatment by washing, rubbing down and stopping of old decorated surfaces on walls, preparation for distempering and applying two coat of oilbound distemper over a coat of primer including stopping of nails holes,cracks etc and levelling with minimum 1 mm thick white cement based wall care putty for obtaining plain surface complete all as specified and directed.

500

-

-

... More
Preparation of old surfaces on walls (plastered or unplastered or previously distempered ) and applying one coat of Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification. complete all as specified.

300

-

-

... More
M & L for preparation of old wooden surfaces of any description over 10cm width or girth & applying one coat of synthetic enamel paint complete all as specified.

100

-

-

... More
M & L for preparation of old painted steel surfaces of any description and applying one coat of synthetic enamel paint complete all as specified and directed.

100

-

-

... More
M & L for preparation of old surfaces for applying one coat of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resisitance as per IS 15489:2004, alkali & fungal rsistance, dirt resistance exterior paint of required shades(Company Depot Tinted) with silicon additives @ 1.43 litre/10sqm Note : A sum of Rs 55,415.00 towards sch of credit shall be deducted to arrive the contract sum

1565

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.