Mazagon Dock Shipbuilders Limited Tender

Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.

Mazagon Dock Shipbuilders Limited - MDL Tender

Services
Electrical and Electronics
Eprocure
Opening Date12 Sep 2019
Closing Date22 Oct 2019
Tender AmountRefer Documents 
Notes
Download

Costs

Summary

Hvac Services For P17a Ships At Mdl And Grse

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
INST. OF RECT. TRUNK (WIDTH 301TO 150MM)

2500

-

-

... More
INST. OF RECT. TRUNK (WIDTH 451 TO800MM)

1532

-

-

... More
FABRICATION OF RECTANGULAR TRUNKS(WT/GT)

119716

-

-

... More
INST. OF RECT. TRUNK (WIDTH UPTO 150 MM)

1072

-

-

... More
INST. OF RECT. TRUNK (WIDTH 151TO300MM)

1092

-

-

... More
INST. OF RECT. TRUNK (WIDTH 301TO450MM)

816

-

-

... More
INST. OF RECT. TRUNK (WIDTH 451TO800MM)

780

-

-

... More
FABRICATION OF CIRCULAR DUCT (NON-WT)

24252

-

-

... More
INST. OF CIRC. DUCT(OD=80MM)

2860

-

-

... More
INST. OF CIRC. DUCT(OD=100MM)

488

-

-

... More
INST. OF CIRC. DUCT(OD=125MM)

988

-

-

... More
INST. OF CIRC. DUCT(OD=160MM)

1144

-

-

... More
INST. OF CIRC. DUCT(OD=200MM)

856

-

-

... More
INST. OF CIRC. DUCT(OD=250MM)

188

-

-

... More
INST. OF CIRC. DUCT(OD=315MM)

16

-

-

... More
FABRICATION OF CIRCULAR DUCT (WT/GT)

26128

-

-

... More
INST. OF CIRC. DUCT(OD=80MM)

808

-

-

... More
INST. OF CIRC. DUCT(OD=100MM)

76

-

-

... More
INST. OF CIRC. DUCT(OD=125MM)

196

-

-

... More
INST. OF CIRC. DUCT(OD=160MM)

548

-

-

... More
INST. OF CIRC. DUCT(OD=200MM)

212

-

-

... More
INST. OF CIRC. DUCT(OD=250MM)

20

-

-

... More
FABRICATION OF DOUBLE SPIRAL DUCT (PRE-INSULATED)

22000

-

-

... More
INST. OF SPIRAL DUCT(OD=100.2MM)

1380

-

-

... More
INST. OF SPIRAL DUCT(OD=125.6MM)

588

-

-

... More
Inst. of SPIRAL Duct(OD=151MM)

1164

-

-

... More
Inst. of SPIRAL Duct(OD=176.4MM)

1180

-

-

... More
Inst. of SPIRAL Duct(OD=227.2MM)

1140

-

-

... More
INSTALLATION OF DUST FILTER- from 151 to 300mm

4

-

-

... More
INSTALLATION OF DUST FILTER- from 301 to 450 mm

4

-

-

... More
INSTALLATION OF DUST FILTER- from 451mm & above

108

-

-

... More
INSTALLATION OF ODOUR FILTER- from 151 to 300mm

4

-

-

... More
INSTALLATION OF ODOUR FILTER- from 301 to 450 mm

16

-

-

... More
INSTALLATION OF HEPA FILTER- from 451mm & above

4

-

-

... More
INSTALLATION OF FIRE DAMPER- from 151 to 300mm

8

-

-

... More
INSTALLATION OF FIRE DAMPER- from 301 to 450mm

8

-

-

... More
INSTALLATION OF FIRE DAMPER- from 451mm & above

8

-

-

... More
INSTALLATION OF SMOKE DAMPER- from 301 to 450mm

16

-

-

... More
INSTALLATION OF SMOKE DAMPER- from 451mm & above

12

-

-

... More
INSTALLATION OF CONTROL DAMPER- from 151 to 300mm

24

-

-

... More
INSTALLATION OF CONTROL DAMPER- from 301 to 450mm

4

-

-

... More
INSTALLATION OF CONTROL DAMPER- from 451mm & above

8

-

-

... More
INSTALLATION OF NR DAMPER- upto 150mm

16

-

-

... More
INSTALLATION OF NR DAMPER- from 151 to 300mm

48

-

-

... More
INSTALLATION OF NR DAMPER- from 301 to 450mm

48

-

-

... More
INSTALLATION OF NR DAMPER- from 451mm & above

40

-

-

... More
INSTALLATION OF ELECTRIC HEATER- upto 150mm

44

-

-

... More
INSTALLATION OF ELECTRIC HEATER- from 151 to 300mm

56

-

-

... More
INSTALLATION OF ELECTRIC HEATER- from 301 to 450mm

12

-

-

... More
INSTALLATION OF FLAME PROOF GAUGE- from 151 to 300mm

144

-

-

... More
INSTALLATION OF FLAME PROOF GAUGE- from 301 to 450mm

48

-

-

... More
INSTALLATION OF FLAME PROOF GAUGE- from 451mm & above

48

-

-

... More
INSTALLATION OF GOOSE NECK- up to 150mm

52

-

-

... More
INSTALLATION OF GOOSE NECK- from 151 to 300mm

12

-

-

... More
INSTALLATION OF GOOSE NECK- from 301 to 450mm

16

-

-

... More
INSTALLATION OF GOOSE NECK- from 451 & above

32

-

-

... More
INSTALLATION OF HONEYCOMB FILTER- up to 150mm

48

-

-

... More
INSTALLATION OF HONEYCOMB FILTER- from 151 to 300mm

68

-

-

... More
INSTALLATION OF HONEYCOMB FILTER- from 301 to 450mm

8

-

-

... More
INSTALLATION OF HONEYCOMB FILTER- from 451 & above

20

-

-

... More
INSTALLATION OF JALOUSY- from 301 to 450mm

8

-

-

... More
INSTALLATION OF JALOUSY- from 451mm & above

32

-

-

... More
INSTALLATION OF CANVAS BELLOWS FOR ATU (30x2)

240

-

-

... More
INSTALLATION OF CANVAS BELLOWS FOR HE (29x2)

232

-

-

... More
INSTALLATION OF CANVAS BELLOWS FOR AFU (11x2)

88

-

-

... More
INSTALLATION OF CANVAS BELLOWS FOR FAN (71x2)

568

-

-

... More
INSTALLATION OF AIR OPERATED QUICK CLOSING VALVE (AOQCV)- up to 150mm

28

-

-

... More
INSTALLATION OF AIR OPERATED QUICK CLOSING VALVE (AOQCV)- from 151 to 300mm

316

-

-

... More
INSTALLATION OF AIR OPERATED QUICK CLOSING VALVE (AOQCV)- from 301 to 450mm

96

-

-

... More
INSTALLATION OF AIR OPERATED QUICK CLOSING VALVE (AOQCV)- from 451mm & above

72

-

-

... More
INSTALLATION OF WATER TIGHT BUTTERFLY VALVE (WTBV)- up to 150mm

20

-

-

... More
INSTALLATION OF WATER TIGHT BUTTERFLY VALVE (WTBV)- from 151 to 300mm

160

-

-

... More
INSTALLATION OF WATER TIGHT BUTTERFLY VALVE (WTBV)- from 301 to 450mm

100

-

-

... More
INSTALLATION OF WATER TIGHT BUTTERFLY VALVE (WTBV)- from 451mm & above

12

-

-

... More
INSTALLATION OF PUNKHA LOUVERS- up to 150mm

160

-

-

... More
INSTALLATION OF PUNKHA LOUVERS- from 151 to 300mm

208

-

-

... More
INSTALLATION OF MUSHROOM HEAD- up to 150mm

12

-

-

... More
INSTALLATION OF MUSHROOM HEAD- from 151 to 300mm

20

-

-

... More
INSTALLATION OF MUSHROOM HEAD- from 301 to 450mm

24

-

-

... More
INSTALLATION OF MUSHROOM HEAD- 451mm & above

4

-

-

... More
INSTALLATION OF SMOKE COUPLING- from 151 to 300mm

108

-

-

... More
INSTALLATION OF AIR BLEED VALVE (ABV)- up to 150mm

20

-

-

... More
INSTALLATION OF AIR BLEED VALVE (ABV)- from 151 to 300mm

124

-

-

... More
INSTALLATION OF AIR BLEED VALVE (ABV)- from 301 to 450mm

4

-

-

... More
INSTALLATION OF DIFFUSERS (CS)- up to 150mm

1208

-

-

... More
FABRICATION OF MANUAL DAMPER FOR RECT. TRUNK- up to 150mm

640

-

-

... More
INSTALLATION OF MANUAL DAMPER FOR RECT. TRUNK- up to 150mm

640

-

-

... More
FABRICATION OF MANUAL DAMPER FOR RECT. TRUNK- from 151 to 300mm

496

-

-

... More
INSTALLATION OF MANUAL DAMPER FOR RECT. TRUNK- from 151 to 300mm

496

-

-

... More
FABRICATION OF MANUAL DAMPER FOR RECT. TRUNK- from 301 to 450mm

244

-

-

... More
INSTALLATION OF MANUAL DAMPER FOR RECT. TRUNK- from 301 to 450mm

244

-

-

... More
FABRICATION OF MANUAL DAMPER FOR RECT. TRUNK- from 451mm & above

164

-

-

... More
INSTALLATION OF MANUAL DAMPER FOR RECT. TRUNK- from 451mm & above

164

-

-

... More
FABRICATION OF DECK/BHD COAMINGS FOR RECT. TRUNKS- up to 150mm

60

-

-

... More
INSTALLATION OF DECK/BHD COAMINGS FOR RECT. TRUNKS- up to 150mm

60

-

-

... More
FABRICATION OF DECK/BHD COAMINGS FOR RECT. TRUNKS- from 151 to 300mm

480

-

-

... More
INSTALLATION OF DECK/BHD COAMINGS FOR RECT. TRUNKS- from 151 to 300mm

480

-

-

... More
FABRICATION OF DECK/BHD COAMINGS FOR RECT. TRUNKS- from 301 to 450mm

288

-

-

... More
INSTALLATION OF DECK/BHD COAMINGS FOR RECT. TRUNKS- from 301 to 450mm

288

-

-

... More
FABRICATION OF DECK/BHD COAMINGS FOR RECT. TRUNKS- from 451mm & above

192

-

-

... More
INSTALLATION OF DECK/BHD COAMINGS FOR RECT. TRUNKS- from 451mm & above

192

-

-

... More
FABRICATION OF DECK/BHD COAMINGS FOR CIRCULAR DUCTS- OD up to 150mm

312

-

-

... More
INSTALLATION OF DECK/BHD COAMINGS FOR CIRCULAR DUCTS- OD up to 150mm

312

-

-

... More
FABRICATION OF DECK/BHD COAMINGS FOR CIRCULAR DUCTS- OD from 151 to 300mm

1200

-

-

... More
INSTALLATION OF DECK/BHD COAMINGS FOR CIRCULAR DUCTS- OD from 151 to 300mm

1200

-

-

... More
FABRICATION OF MANUAL DAMPER FOR SPIRAL DUCT- OD up to 150mm

936

-

-

... More
INSTALLATION OF MANUAL DAMPER FOR SPIRAL DUCT- OD up to 150mm

936

-

-

... More
FABRICATION OF MANUAL DAMPER FOR SPIRAL DUCT- OD from 151 to 300mm

756

-

-

... More
INSTALLATION OF MANUAL DAMPER FOR SPIRAL DUCT- OD from 151 to 300mm

756

-

-

... More
FABRICATION OF PLAIN HANGER FOR RECT. TRUNK- up to 150mm

1400

-

-

... More
INSTALLATION OF PLAIN HANGER FOR RECT. TRUNK- up to 150mm

1400

-

-

... More
FABRICATION OF PLAIN HANGER FOR RECT. TRUNK- from 151 to 300mm

3600

-

-

... More
INSTALLATION OF PLAIN HANGER FOR RECT. TRUNK- from 151 to 300mm

3600

-

-

... More
FABRICATION OF PLAIN HANGER FOR RECT. TRUNK- from 301 to 450mm

720

-

-

... More
INSTALLATION OF PLAIN HANGER FOR RECT. TRUNK- from 301 to 450mm

720

-

-

... More
FABRICATION OF PLAIN HANGER FOR RECT. TRUNK- from 451mm & above

1000

-

-

... More
INSTALLATION OF PLAIN HANGER FOR RECT. TRUNK- from 451mm & above

1000

-

-

... More
FABRICATION OF PLAIN HANGER FOR SPIRAL DUCT- OD up to 150mm

408

-

-

... More
INSTALLATION OF PLAIN HANGER FOR SPIRAL DUCT- OD up to 150mm

408

-

-

... More
FABRICATION OF PLAIN HANGER FOR SPIRAL DUCT- OD from 151 to 300mm

2864

-

-

... More
INSTALLATION OF PLAIN HANGER FOR SPIRAL DUCT- OD from 151 to 300mm

2864

-

-

... More
FABRICATION OF SPRING HANGERS FOR RECT. TRUNK- up to 150mm

400

-

-

... More
INSTALLATION OF SPRING HANGERS FOR RECT. TRUNK- up to 150mm

400

-

-

... More
FABRICATION OF SPRING HANGERS FOR RECT. TRUNK- from 151 to 300mm

400

-

-

... More
INSTALLATION OF SPRING HANGERS FOR RECT. TRUNK- from 151 to 300mm

400

-

-

... More
FABRICATION OF SPRING HANGERS FOR RECT. TRUNK- from 301 to 450mm

200

-

-

... More
INSTALLATION OF SPRING HANGERS FOR RECT. TRUNK- from 301 to 450mm

200

-

-

... More
FABRICATION OF SPRING HANGERS FOR RECT. TRUNK- from 451mm & above

200

-

-

... More
INSTALLATION OF SPRING HANGERS FOR RECT. TRUNK- from 451mm & above

200

-

-

... More
FABRICATION OF SPRING HANGERS FOR SPIRAL DUCT- OD up to 150mm

188

-

-

... More
INSTALLATION OF SPRING HANGERS FOR SPIRAL DUCT- OD up to 150mm

188

-

-

... More
FABRICATION OF SPRING HANGERS FOR SPIRAL DUCT- OD from 151 to 300mm

1108

-

-

... More
INSTALLATION OF SPRING HANGERS FOR SPIRAL DUCT- OD from 151 to 300mm

1108

-

-

... More
FABRICATION OF WIRE MESH FRAME FOR TRUNKS- up to 150mm

100

-

-

... More
INSTALLATION OF WIRE MESH FRAME FOR TRUNKS- up to 150mm

100

-

-

... More
FABRICATION OF WIRE MESH FRAME FOR TRUNKS- from 151 to 300mm

800

-

-

... More
INSTALLATION OF WIRE MESH FRAME FOR TRUNKS- from 151 to 300mm

800

-

-

... More
FABRICATION OF WIRE MESH FRAME FOR TRUNKS- from 301 to 450mm

600

-

-

... More
INSTALLATION OF WIRE MESH FRAME FOR TRUNKS- from 301 to 450mm

600

-

-

... More
FABRICATION OF WIRE MESH FRAME FOR TRUNKS- from 451mm & above

100

-

-

... More
INSTALLATION OF WIRE MESH FRAME FOR TRUNKS- from 451mm & above

100

-

-

... More
FABRICATION OF WIRE MESH FRAME ON BULKHEADS- up to 150mm

200

-

-

... More
INSTALLATION OF WIRE MESH FRAME ON BULKHEADS- up to 150mm

200

-

-

... More
FABRICATION OF WIRE MESH FRAME ON BULKHEADS- from 151 to 300mm

600

-

-

... More
INSTALLATION OF WIRE MESH FRAME ON BULKHEADS- from 151 to 300mm

600

-

-

... More
INSULATION OF TRUNKING/DUCTING (32mm Elastomeric Nitrile Thermal Insulation + Adhesive + Sealing Tape)

17600

-

-

... More
INSULATION OF TRUNKING/DUCTING FLANGES(9mm/32mm Elastomeric Nitrile Thermal Insulation + Adhesive + Sealing Tape)

1600

-

-

... More
FABRICATION OF FINISHED SPOOL BY SILVER BRAZING-20NB

200

-

-

... More
FABRICATION OF FINISHED SPOOL BY SILVER BRAZING-25NB

1000

-

-

... More
FABRICATION OF FINISHED SPOOL BY SILVER BRAZING-32NB

1000

-

-

... More
FABRICATION OF FINISHED SPOOL BY SILVER BRAZING-40NB

440

-

-

... More
FABRICATION OF FINISHED SPOOL BY TIG WELDING-32NB

400

-

-

... More
FABRICATION OF FINISHED SPOOL BY TIG WELDING-40NB

1760

-

-

... More
FABRIACTION OF FINISHED SPOOL BY TIG WELDING-50NB

800

-

-

... More
FABRICATION OF FINISHED SPOOL BY TIG WELDING-65NB

500

-

-

... More
FABRICATION OF FINISHED SPOOL BY TIG WELDING-80NB

300

-

-

... More
FABRICATION OF FINISHED SPOOL BY TIG WELDING-100NB

600

-

-

... More
FABRICATION OF FINISHED SPOOL BY TIG WELDING-150NB

600

-

-

... More
INSTALLATION OF FINISHED SPOOL-FROM 20NB TO 32NB

2600

-

-

... More
INSTALLATION OF FINISHED SPOOL-From 40NB to 65 NB

3500

-

-

... More
INSTALLATION OF FINISHED SPOOL- 80NB

300

-

-

... More
INSTALLATION OF FINISHED SPOOL- 100NB

600

-

-

... More
INSTALLATION OF FINISHED SPOOL-150NB

600

-

-

... More
SUPPLY AND FITMENT OF 90/10 Cu-Ni LR ELBOW-150NB

560

-

-

... More
SUPPLY AND FITMENT OF 90/10 Cu-Ni LR ELBOW-100NB

360

-

-

... More
SUPPLY AND FITMENT OF 90/10 Cu-Ni LR ELBOW-80NB

160

-

-

... More
SUPPLY AND FITMENT OF 90/10 Cu-Ni LR ELBOW-65NB

360

-

-

... More
SUPPLY AND FITMENT OF 90/10 Cu-Ni LR ELBOW-50NB

960

-

-

... More
SUPPLY AND FITMENT OF 90/10 Cu-Ni LR ELBOW-40NB

880

-

-

... More
SUPPLY AND FITMENT OF Al-Brass ELBOW-32NB

520

-

-

... More
SUPPLY AND FITMENT OF Al-Brass ELBOW-25NB

520

-

-

... More
SUPPLY AND FITMENT OF 90/10 Cu-Ni EQUAL TEE -150NB

140

-

-

... More
SUPPLY AND FITMENT OF 90/10 Cu-Ni EQUAL TEE -50NB

340

-

-

... More
SUPPLY AND FITMENT OF 90/10 Cu-Ni EQUAL TEE -40NB

40

-

-

... More
SUPPLY AND FITMENT OF Al-Brass EQUALTEE -32NB

40

-

-

... More
SUPPLY AND FITMENT OF Al-Brass EQUAL TEE -25NB

80

-

-

... More
SUPPLY AND FITMENT OF 90/10 Cu-Ni UNEQ TEE 50X40X40

40

-

-

... More
SUPPLY AND FITMENT OF Al-Brass UNEQ TEE 40x40x32

80

-

-

... More
SUPPLY AND FITMENT OF Al-Brass UNEQ TEE 40x40x25

80

-

-

... More
SUPPLY AND FITMENT OF Al-Brass UNEQUAL TEE 32x32x25

40

-

-

... More
SUPPLY AND FITMENT OF 90/10 Cu-Ni EQUAL TEE -65NB

160

-

-

... More
SUPPLY AND FITMENT OF Al-Brass REDUCER 40-32

40

-

-

... More
SUPPLY AND FITMENT OF Al-Brass REDUCER 40-25

40

-

-

... More
SUPPLY AND FITMENT OF 90/10 Cu-Ni REDUCER 65-40

80

-

-

... More
SUPPLY AND FITMENT OF 90/10 Cu-Ni REDUCER 100-80

80

-

-

... More
SUPPLY AND FITMENT OF 90/10 Cu-Ni REDUCER 80-65

80

-

-

... More
SUPPLY AND FITMENT OF 90/10 Cu-Ni REDUCER 65-50

80

-

-

... More
SUPPLY AND FITMENT OF 90/10 Cu-Ni REDUCER 50-40

120

-

-

... More
SUPPLY AND FITMENT OF 90/10 Cu-Ni REDUCER 50-32

120

-

-

... More
SUPPLY AND FITMENT OF Al-Brass REDUCER 32-25

40

-

-

... More
SUPPLY AND FITMENT OF Al-Brass Union connectors-40NB

160

-

-

... More
SUPPLY AND FITMENT OF Al-Brass Union connectors-32NB

120

-

-

... More
SUPPLY AND FITMENT OF Al-Brass Union connectors-25NB

160

-

-

... More
SUPPLY AND FITMENT OF FLANGE LESS COUPLING / GRIP COUPLING-20NB

80

-

-

... More
SUPPLY AND FITMENT OF FLANGE LESS COUPLING / GRIP COUPLING-25NB

640

-

-

... More
SUPPLY AND FITMENT OF FLANGE LESS COUPLING / GRIP COUPLING-32NB

600

-

-

... More
SUPPLY AND FITMENT OF FLANGE LESS COUPLING / GRIP COUPLING-40NB

600

-

-

... More
SUPPLY AND FITMENT OF FLANGE LESS COUPLING / GRIP COUPLING-50NB

320

-

-

... More
SUPPLY AND FITMENT OF FLANGE LESS COUPLING / GRIP COUPLING-100NB

80

-

-

... More
SUPPLY AND FITMENT OF FLANGE LESS COUPLING / GRIP COUPLING-150NB

240

-

-

... More
SUPPLY AND FITMENT OF FLANGE LESS COUPLING / GRIP COUPLING-65NB

200

-

-

... More
SUPPLY AND FITMENT OF FLANGE LESS COUPLING / GRIP COUPLING-80NB

120

-

-

... More
SUPPLY OF IMPROVISED DK/BHD SLEEVE TYPE FITTING-20NB

40

-

-

... More
SUPPLY OF IMPROVISED DK/BHD SLEEVE TYPE FITTING-25NB

64

-

-

... More
SUPPLY OF IMPROVISED DK/BHD SLEEVE TYPE FITTING-32NB

48

-

-

... More
SUPPLY OF IMPROVISED DK/BHD SLEEVE TYPE FITTING-40NB

64

-

-

... More
SUPPLY OF IMPROVISED DK/BHD SLEEVE TYPE FITTING-50NB

160

-

-

... More
SUPPLY OF IMPROVISED DK/BHD SLEEVE TYPE FITTING-65NB

68

-

-

... More
SUPPLY OF IMPROVISED DK/BHD SLEEVE TYPE FITTING-80NB

112

-

-

... More
SUPPLY OF IMPROVISED DK/BHD SLEEVE TYPE FITTING-100NB

16

-

-

... More
SUPPLY OF IMPROVISED DK/BHD SLEEVE TYPE FITTING-150NB

16

-

-

... More
SUPPLY OF Deck/Bhd Piece With Improvised Sleeve-25NB

40

-

-

... More
SUPPLYT OF Deck/Bhd Piece With Improvised Sleeve-50NB

80

-

-

... More
SUPPLY OF Deck/Bhd Piece With Improvised Sleeve-80NB

40

-

-

... More
SUPPLY OF Deck/Bhd Piece With Improvised Sleeve-100NB

40

-

-

... More
SUPPLY OF Deck/Bhd Piece With Improvised Sleeve-150NB

120

-

-

... More
SUPPLY AND FITMENT OF Composite Flange-32NB

400

-

-

... More
SUPPLY AND FITMENT OF Composite Flange-40NB

600

-

-

... More
SUPPLY AND FITMENT OF Composite Flange-50NB

280

-

-

... More
SUPPLY AND FITMENT OF Composite Flange-65NB

160

-

-

... More
SUPPLY AND FITMENT OF Composite Flange-80NB

120

-

-

... More
SUPPLY AND FITMENT OF Composite Flange-100NB

200

-

-

... More
SUPPLY AND FITMENT OF Composite Flange-150NB

600

-

-

... More
INSTALLATION OF IMPROVISED DECK/BHD SLEEVE TYPE FITTINGS-From 20NB to 32NB

192

-

-

... More
INSTALLATION OF IMPROVISED DECK/BHD SLEEVE TYPE FITTINGS-From 40NB to 65 NB

372

-

-

... More
INSTALLATION OF IMPROVISED DECK/BHD SLEEVE TYPE FITTINGS-80NB

112

-

-

... More
INSTALLATION OF IMPROVISED DECK/BHD SLEEVE TYPE FITTINGS-100NB

56

-

-

... More
INSTALLATION OF IMPROVISED DECK/BHD SLEEVE TYPE FITTINGS-150NB

136

-

-

... More
INSTALLATION OF VALVE/STRAINERS/FLOW METER- Up to 20NB

120

-

-

... More
INSTALLATION OF VALVE/STRAINERS/FLOW METER- 80NB

32

-

-

... More
INSTALLATION OF VALVE/STRAINERS/FLOW METER- 100NB

40

-

-

... More
INSTALLATION OF VALVE/STRAINERS/FLOW METER- 150NB

48

-

-

... More
INSTALLATION INSPECTION AND PRESSURE TESTING OF PIPES- Up to 50NB

5600

-

-

... More
INSTALLATION INSPECTION AND PRESSURE TESTING OF PIPES- 65NB to 100NB

1400

-

-

... More
INSTALLATION INSPECTION AND PRESSURE TESTING OF PIPES- 150NB

600

-

-

... More
FILLING OF DISTILLED WATER/FRESH WATER

7600

-

-

... More
COLD INSULATION OF CHILLED WATER SYSTEM PIPES- 20NB

200

-

-

... More
COLD INSULATION OF CHILLED WATER SYSTEM PIPES- 25NB

1000

-

-

... More
COLD INSULATION OF CHILLED WATER SYSTEM PIPES- 32NB

1400

-

-

... More
COLD INSULATION OF CHILLED WATER SYSTEM PIPES- 40NB

2200

-

-

... More
COLD INSULATION OF CHILLED WATER SYSTEM PIPES- 50NB

800

-

-

... More
COLD INSULATION OF CHILLED WATER SYSTEM PIPES- 65NB

500

-

-

... More
COLD INSULATION OF CHILLED WATER SYSTEM PIPES- 80NB

300

-

-

... More
COLD INSULATION OF CHILLED WATER SYSTEM PIPES- 100NB

600

-

-

... More
COLD INSULATION OF CHILLED WATER SYSTEM PIPES- 150NB

600

-

-

... More
COLD INSULATION OF FLANGES- 40NB

1600

-

-

... More
COLD INSULATION OF FLANGES- 50NB

600

-

-

... More
COLD INSULATION OF FLANGES- 65NB

360

-

-

... More
COLD INSULATION OF FLANGES- 80NB

240

-

-

... More
COLD INSULATION OF FLANGES- 100NB

400

-

-

... More
COLD INSULATION OF FLANGES- 150NB

400

-

-

... More
Cold Insulation of Chilled water system Valves/Strainers/Flow meter- 80NB

32

-

-

... More
Cold Insulation of Chilled water system Valves/Strainers/Flow meter- 100NB

40

-

-

... More
Cold Insulation of Chilled water system Valves/Strainers/Flow meter- 150NB

48

-

-

... More
Services of technicians for assistance during HVAC trials, commissioning of system, citadel trials and for maintenance of system on board.

2000

-

-

... More
Services of engineers/draftsmen for extraction of 2D production drawings of ducting/trunking at shipyard: A4 Size as per Part-III of SoW

20000

-

-

... More
Services of engineers/draftsmen for extraction of 2D production drawings of ducting/ trunking at shipyard: A3 Size as per Part-III of SoW

1800

-

-

... More
Services of engineers/draftsmen for extraction of 2D production drawings of piping spools at shipyard: A4 Size as per Part-III of SoW

17800

-

-

... More
Services of engineers/draftsmen for extraction of 2D production drawings of piping spools at shipyard: A3 Size as per Part-III of SoW

1400

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.