Maharashtra State Infrastructure Development Corporation Tender

Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.

Maharashtra State Infrastructure Development Corporation - MSIDC Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date2 Aug 2024
Closing Date23 Aug 2024
Tender Amount₹ 2,34,73,73,378 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Excavation for foundation in Soft rock and old cement or lime masonry foundations including removing the excavated material upto a distance of 50 metres beyond the building area and stacking as directed, including dewatering, preparing the bed for the foundation and necessary back filling with available earth/murum, ramming ,watering including shoring and strutting etc. complete. (Lift from 1.5m To 3.0 m.) By Mechanical Means

2940

-

-

... More
Excavation for foundation in Soft rock and old cement or lime masonry foundations including removing the excavated material upto a distance of 50 metres beyond the building area and stacking as directed, including dewatering, preparing the bed for the foundation and necessary back filling with available earth/murum, ramming ,watering including shoring and strutting etc. complete. (Lift from 3.0m to 4.5 m.) By Mechanical Means.

2940

-

-

... More
Excavation for foundation in Soft rock and old cement or lime masonry foundations including removing the excavated material upto a distance of 50 metres beyond the building area and stacking as directed, including dewatering, preparing the bed for the foundation and necessary back filling with available earth/murum, ramming ,watering including shoring and strutting etc. complete. (Lift from 4.5m to 6.0m.) By Mechanical Means.

2100

-

-

... More
Filling in plinth and floors with approved excavated material in 15cm. to 20cm. Layers including watering and compacting etc. complete.

25254

-

-

... More
Providing and filling in the foundation with sand of approved quality including watering, compacting etc. complete. (To be executed with prior approval of Superintending Engineer)

3255

-

-

... More
Providing selected hard murum filling including laying in layers of 15 to 20 cm with watering and compacting etc. complete.

59259

-

-

... More
Providing preconstructional antitermite treatment as per I.S. 6313 (Part-II) by treating the bottom surface and sides of excavation at the rate of 5 litres of emulsion concentrate of 1.0 percent of chlorophyrifos per square meter of surface area covering 10 years guarantee on bond paper.

27887

-

-

... More
Providing preconstructional antitermite treatment as per I.S. 6313 (Part-II) by treating the top surface of plinth filling at the rate of 5 litres of emulsion concentrate at 1.0 percent of clorophyrifos per One Square Metre of surface area covering ten years guarantee on bond paper.

33629

-

-

... More
Providing preconstructional antitermite treatment as per I.S. 6313 (Part-I) to the soil along the external face of building by punching holes of 1.2 of 1.5 C.M. diametre about 30 -60 cm deep at 15 cm c/c as close to the wall as possible and to inject 0.5 percent of aldrin or clorophyrifos at the rate of 7.5 litres per hole and sealing the same with proper filling and covering 10 years guarantee on bond paper.

5140

-

-

... More
Providing and laying Cast in situ/Ready Mix cement concrete in M-10 of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including bailing out water, Steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing if required and curing complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)

2233

-

-

... More
Providing and laying Cast in situ/ Ready Mix cement concrete M-15 of trap/ granite/ quartzite/ gneiss metal for coping to plinth or parapet, moulded or chamfered as per drawing or as directed including steel centering, plywood/ steel formwork compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.) With fine aggregate (Crushed sand VSI Grade)Basement Floor/ Under Ground Tank

89

-

-

... More
Ground / Stilt Floor

3146

-

-

... More
First/ Mezzanne/ Podium Floor

90

-

-

... More
Second Floor

65

-

-

... More
Third Floor

22

-

-

... More
Fourth Floor/ Terrace Floor/ Mumty

12

-

-

... More
Providing & filling the broken light weight Autoclaved Aerated Concrete (AAC) blocks in sunken area including filling the voids with small pieces with 551-650 Kgs. per cum conforming to IS: 2185 (Part:3) for all levels, floors & heights.

588

-

-

... More
Providing and laying Cast in situ/ Ready Mix cement concrete M-25 of trap / granite/quartzite/ gneiss metal for R.C.C. work in foundations like raft, strip foundations, grillage and footings of R.C.C. columns and steel stanchions etc. including bailing out water, Steel centering, formwork ,cover blocks, laying/pumping, compaction and curing roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)

10815

-

-

... More
Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap / granite /quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)Basement Floor/ Under Ground Tank

8

-

-

... More
Ground / Stilt Floor

1768

-

-

... More
First/ Mezzanne/ Podium Floor

1154

-

-

... More
Second Floor

900

-

-

... More
Third Floor

340

-

-

... More
Fourth Floor/ Terrace Floor/ Mumty

265

-

-

... More
Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap/ granite/ quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)Basement Floor/ Under Ground Tank

32

-

-

... More
Ground / Stilt Floor

2300

-

-

... More
First/ Mezzanne/ Podium Floor

1611

-

-

... More
Second Floor

1076

-

-

... More
Third Floor

389

-

-

... More
Fourth Floor/ Terrace Floor/ Mumty

273

-

-

... More
Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap/ granite / quartzite/ gneiss metal for R.C.C. slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)Basement Floor/ Under Ground Tank

229

-

-

... More
Ground / Stilt Floor

3065

-

-

... More
First/ Mezzanne/ Podium Floor

2116

-

-

... More
Second Floor

1492

-

-

... More
Third Floor

650

-

-

... More
Fourth Floor/ Terrace Floor/ Mumty

419

-

-

... More
Providing and laying Cast in situ/Ready Mixcement concrete M-25 of trap/ granite/ quartzite/ gneiss metal for R.C.C. chajja as per detailed design and drawings including steel centering, formwork, cover blocks, laying/pumping, compacting and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)Basement Floor/ Under Ground Tank

2

-

-

... More
Ground / Stilt Floor

94

-

-

... More
First/ Mezzanne/ Podium Floor

69

-

-

... More
Second Floor

53

-

-

... More
Third Floor

26

-

-

... More
Fourth Floor/ Terrace Floor/ Mumty

12

-

-

... More
Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap / quartzite/granite /gneiss metal for R.C.C. Waist slab, and steps of staircases as per detailed design and drawings or as directed including steel centering, plywood/ steel formwork, steel props, laying/pumping, compaction, finishing uneven and honeycombed surface with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing etc. complete. (Excluding einforcement, including cover block).(Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc.) with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)Basement Floor/ Under Ground Tank

10

-

-

... More
Ground / Stilt Floor

153

-

-

... More
First/ Mezzanne/ Podium Floor

120

-

-

... More
Second Floor

102

-

-

... More
Third Floor

54

-

-

... More
Fourth Floor/ Terrace Floor/ Mumty

32

-

-

... More
Providing and laying Cast in situ/Ready Mix cement concrete in M-20 of trap/ granite/ quartzite/ gneiss metal for R.C.C.coping to plinth or parapet and sill of doors and windows moulded as per detailed drawings or chamfered as approved by the Engineer including steel centering, formwork, cover blocks, laying/pumping, compacting , curing , finishing and roughening them if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)Ground / Stilt Floor

44

-

-

... More
First/ Mezzanne/ Podium Floor

25

-

-

... More
Second Floor

26

-

-

... More
Third Floor

8

-

-

... More
Fourth Floor/ Terrace Floor/ Mumty

7

-

-

... More
Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete.Basement Floor/ Under Ground Tank

148

-

-

... More
Ground / Stilt Floor

1990

-

-

... More
First/ Mezzanne/ Podium Floor

827

-

-

... More
Second Floor

620

-

-

... More
Third Floor

194

-

-

... More
Fourth Floor/ Terrace Floor/ Mumty

163

-

-

... More
Providing and mixing integral crystalline admixture for water proofing treatment to RCC structures like basement raft, retaining walls, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc. at the time of transporting of concrete into the drum of the ready-mix truck , using integral crystalline admixture @0.80% (minimum) to the weight of cement content per cubic meter of concrete) or higher as recommended by the manufacturer's specification in reinforced cement concrete at site of work. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e. by reducing permeability of concrete by more than 90%, compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure. The crystalline admixture shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the Engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage.

5339

-

-

... More
Providing expansion joints in reinforced cement concrete framed structure (interior columns) with plain premoulded filler with confirming to IS 1838,1961, 25 mm thick with 75 mm wide and 1 mm thick stainless steel plate finishing etc. complete as directed

35

-

-

... More
Providing expansion joints in R.C.C. framed structure (exterior column) with plain premoulded filler 25 mm thick with 75 mm wide and 1 mm thick stainless steel plate and finishing etc. complete.

352

-

-

... More
Providing expansion joints in R.C.C. framed structure (at floor level) with plain premoulded filler 25 mm thick with 75 mm wide and 1 mm thick stainless steel plat and finishing etc. complete.

110

-

-

... More
Providing expansion joints in R.C.C. framed structure (at Terrace level) with premoulded filler 25 mm thick with 40 mm wide and 1 mm thick stainless steel plate as required, bitumen poured filler and finishing etc. complete as directed.

43

-

-

... More
Providing second class Burnt Brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in foundations and plinth of inner walls/ in plinth external walls including bailing out water manually, striking joints on unexposed faces, raking out joints on exposed faces and watering etc. Complete.Basement Floor

854

-

-

... More
Ground / Stilt Floor

2712

-

-

... More
Providing fly ash brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in superstructure including striking joints, raking out joints, watering and scaffolding etc. Complete.Ground / Stilt Floor

6947

-

-

... More
First/ Mezzanne/ Podium Floor

4040

-

-

... More
Second Floor

3008

-

-

... More
Third Floor

1218

-

-

... More
Fourth Floor/ Terrace Floor/ Mumty

904

-

-

... More
Providing Second class fly ash brick masonry with conventional / I.S. type bricks in cement mortar 1:4 in half brick thick wall including mild steel longitudinal reinforcement of two bars of 6 mm diameter / two hoop iron strips 25 mm x 1.60 mm at every third course, properly bent and bounded at ends scaffolding raking out joints and watering etc. complete.Ground / Stilt Floor

3299

-

-

... More
First/ Mezzanne/ Podium Floor

2525

-

-

... More
Second Floor

2666

-

-

... More
Third Floor

1261

-

-

... More
Fourth Floor/ Terrace Floor/ Mumty

809

-

-

... More
Providing and fixing frame with / without ventilator of size as specified with Country cut teak wood for doors and windows including chamfering, rounding, rebating, iron holdfast of size 300mm x 40mm x 5mm with oil painting, etc. completeGround / Stilt Floor

33

-

-

... More
First/ Mezzanne/ Podium Floor

28

-

-

... More
Second Floor

22

-

-

... More
Third Floor

10

-

-

... More
Fourth Floor/ Terrace Floor/ Mumty

5

-

-

... More
Solid Core Flush door Single leafProviding and fixing factory made solid core flush door in single leaf 35 mm thick, decorative types, of exterior grade, as per detailed drawings, conforming to I.S.:2202 - 1962 (Revised) with approved face veneers on both faces with/without glazing and venetians in the positions shown on the drawings or as directed, all necessary beads, moulding and lipping, holdfasts, mat finish stainless steel fixtures fastenings , finishing with french-polish/ waxing complete. (without door frame).(Sample to be got approved from Ex.Engineer before use) Commercial Hard Wood shutterGround / Stilt Floor

967

-

-

... More
First/ Mezzanne/ Podium Floor

769

-

-

... More
Second Floor

583

-

-

... More
Third Floor

223

-

-

... More
Fourth Floor/ Terrace Floor/ Mumty

102

-

-

... More
Providing and fixing in position powder coated extruded aluminium fixed window fully glazed of any size as per detailed drawing and as directed by Engineer in charge with all necessary alluminium sections including necessary fixtures and fastening such as 5 mm thick clear float glass etc. complete. Note While arriving at the rate of item of item weight at 6.90 Kilogram/ One Square Metre is considered.Ground / Stilt Floor

952

-

-

... More
First/ Mezzanne/ Podium Floor

936

-

-

... More
Second Floor

411

-

-

... More
Third Floor

145

-

-

... More
Fourth Floor/ Terrace Floor/ Mumty

35

-

-

... More
Providing and fixing in position (as per 1868 / 1982) Aluminium sliding window of three tracks with rectangular pipe 95 x 38.10 x 0.90 mm at weight 0.637 Kilogram/One Running Metre. with window frame bottom track section 92 x 31.75 x 1.30 mm at weight 1.070 Kilogram/One Running Metre.. Top and side track section 92 x 31.75 x 1.30 mm at weight 0.933 Kilogram/Running metre. The shutter should be of bearing bottom 40 x 18 x 1.25 mm at weight 0.417 Kilogram/One Running Metre. Inter locking section 40 x 18 x 1.10 mm at weight 0.469 Kilogram/Running metre. and handle and top section 40 x 18 x 1.25 mm at weight 0.417 Kilogram/Running metre. As per detailed drawings and as directed by Engineerincharge with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 mm thick plain glass and aluminium mosquito net shutter with stainless steel jail with all required screws and nuts etc, complete. With colour Anodising without boxGround / Stilt Floor

1149

-

-

... More
First/ Mezzanne/ Podium Floor

879

-

-

... More
Second Floor

587

-

-

... More
Third Floor

209

-

-

... More
Fourth Floor/ Terrace Floor/ Mumty

58

-

-

... More
Providing and Fixing mat finish stainless steel (of 302 grade ) railing with top pipe of 50 mm dia. and vertical pipe of 38 mm dia at 0.60 m c/c or as required and horizontal pipes of 25 mm dia in three rows, all pipes of 2 mm thick including buffing,fabricating fixtures and fastening including pipe base of appropriate diameter and ball base of 75 mm dia above newel post of 75 mm diameter etc. complete (Prior approval of sample and brand by Ex.Engineer is necessary before use)Ground / Stilt Floor

726

-

-

... More
First/ Mezzanne/ Podium Floor

590

-

-

... More
Second Floor

506

-

-

... More
Third Floor

176

-

-

... More
Fourth Floor/ Terrace Floor/ Mumty

77

-

-

... More
Providing and fixing mild steel grill railing 15 Kilogram/sq.m with Ghana teak wood hand rail of size 75mm x 60 mm and sill of 75mm.x 25mm and newel posts for staircases, including fabricating, fixtures, erecting, painting the grill work with one coat of anticorrosive paint and two coats of oil painting with approved colours and polishing the sill, hand rail and the newel post with french polish.Basement Floor/ Under Ground Tank

31

-

-

... More
Ground / Stilt Floor

38

-

-

... More
Providing and fixing in position, Double shuttered aluminium extruded powder coated openable door of specified size with aluminium door frame of powder coated section 101.60 x 44.75mm , 3.18 mm thick and shutter comprising of powder coated section having bottom and lock rail of size 150 mm x 44.5 mm x 3.00 mm thick top rails 47.62 x 44.45 mm x 3.00 mm thick , vertical style 47.62 x 44.45 mm, 3.00 mm thick and for shutter plain glass panes 5 mm thick for top panels and 12mm thick both side laminated phenol bonded particle board panels for bottom panels etc. , I.S.I. mark , heavy duty, Hydraulic floor spring of 150Kilogramcapacity , having heavy duty concealed lock, necessary beading, glazing clips, PVC gaskets, 250mm length aluminium tower bolts, 150mm dia. pad handle, etc. as per detailed design and drawing or as directed by engineer in charge including all materials , labours, and equipment etc.completeGround / Stilt Floor

183

-

-

... More
First/ Mezzanne/ Podium Floor

142

-

-

... More
Second Floor

108

-

-

... More
Third Floor

21

-

-

... More
Fourth Floor/ Terrace Floor/ Mumty

11

-

-

... More
Providing and fixing in position, Single shuttered aluminium extruded powder coated openable door of overall size 0.90 m x 2.40 m with aluminium door frame of powder coated section 101.60 x 44.75mm , 3.18 mm thick and shutter comprising of powder coated section having bottom and lock rail of size 150 mm x 44.5 mm x 3.00 mm thick top rails 47.62 x 44.45 mm x 3.00 mm thick , vertical style 47.62 x 44.45 mm, 3.00 mm thick and for shutter plain glass panes 5 mm thick for top panels and 12mm thick both side laminated phenol bonded particle board panels for bottom panels etc. , I.S.I. mark , heavy duty, Hydraulic floor spring of 150Kilogramcapacity , having heavy duty concealed lock, necessary beading, glazing clips, PVC gaskets, 250mm length tower bolts, 150mm diam. pad handle, etc. as per detailed design and drawing or as directed by engineer in charge including all materials , labours, and equipment etc.CompleteGround / Stilt Floor

93

-

-

... More
First/ Mezzanne/ Podium Floor

17

-

-

... More
Second Floor

17

-

-

... More
Third Floor

5

-

-

... More
Providing & Fixing in position Acoustical Doors along with 150 x 150 mm teak wood frame, doors made from 50mm Teak wood frame 600 x600 c to c filled with 1000 Gsm synthetic wool 50mm thick and 3mm Tecsound from both sides, 12mm waterproof ply & veneer from both sides , including 150mm heavy duty SS hinges (Geze / Dorma or eq.) 4 no each leaf, with Door-closer (Dorma / Geze or eq.) including cost of required Cut-Outs, decorative mouldings / finishing-items / melamine polish & Scaffolding as per Architectural & Acoustical Design & Instructions & Complete in all aspects .including all materials labour,finishing etc complete.Ground / Stilt Floor

88

-

-

... More
Fire Door 55mm 2 HR FRL (120/120) 3 Criteria- INTEGRITY/ INSULATION/ STABILITY WOODEN DOOR - Fire Door Tested in accordance to IS: 3614 Part 2. Providing of 120 min Fire rated doors system duly tested for 3 criteria- Integrity, Insulation and Stability Criteria as per the IS: 3614 Part 2 and BS: 476 part 22 at National Test House, Govt. of India laboratory and/ or with Central Building Research Institute, Govt. of India undertaking with standard heating conditions as specified in IS: 3614 Part II 1992 and BS: 476 part 20 & 22 1987 to achieve the required integrity, insulation and stability (i.e. to restrict the heat radiation, temperature rise on the non fire side to the maximum of 140° C above the ambient temperature on the exposed surface of the shutter. The fire doors are tested with NCBN technology ("Non Combustible by Nature").Door Frame: Supplying & fixing frames for Fire resistant door shutters 1st class Malaysian Hardwood Frame densified (810 Kgs./cum)and pressure treated with fire retardant chemicals in vacuum impregnation vessel under 160psi pressure as per IS: 401 and kiln seasoned to moisture below 15% as per IS: 1141 of section 120 x 70mm spray quoted with two coats of intumescent paint of minimum 200 micron, with single row of Brush-Type ASTROFLAME intumescent strip of size 10mm x 4mm affixed in the slit of the frame for fire and smoke sealing, etc. complete.Ground / Stilt Floor

66

-

-

... More
First/ Mezzanne/ Podium Floor

54

-

-

... More
Second Floor

66

-

-

... More
Third Floor

66

-

-

... More
Fourth Floor/ Terrace Floor/ Mumty

56

-

-

... More
Door Shutter: Supplying & Fixing of 55mm thick asbestos free criteria checked-fire, heat and smoke resistant composite Fire check Door Shutter complying with fire performance- FD 120 as per IS: 3614 (Part-II)comprising of 2x8mm Calcium Silicate boards over Chemically treated (with Fire retardant chemicals in vaccum pressure impregnation vessels under 160psi pressure as per IS:401 and kiln seasoned to moisture below 15% as per IS:1141)internal timber (Malaysian Hard Wood, densified to 810 Kilogram/ cum)frame work of 100x32mm with 32mm thick infill of ceramic fiber (density 128 Kilogram/ cum), vermaculite mix faced with 3mm Fire retardant High Density fibre board, internally lipped with hardwood beading and pasted in Hydraulic Press under 25MPa, spray quoted with 2 coats of intumescent paint of minimum 300 micron, and with single row of Brush-Type intumescent strip of size 10mm x 4mm affixed on periphery for fire and smoke sealing in the slit on all edges of shutter except bottom, without any external lipping.Ground / Stilt Floor

35

-

-

... More
First/ Mezzanne/ Podium Floor

28

-

-

... More
Second Floor

35

-

-

... More
Third Floor

35

-

-

... More
Fourth Floor/ Terrace Floor/ Mumty

31

-

-

... More
Vision Panel: 2 HR rated E Class clear high stress fire rated glass is prefabricated strategically inside the shutter structure with 10 mm inside the shutter on all sides with U-glazing. An additional insulated powder coated 'Z' channel of 16 swg MS sheet to be fixed for reinforcement of the joints. With clear fire resistant glass panes 11mm thick having minimum 120 minutes fire rating.Ground / Stilt Floor

3

-

-

... More
First/ Mezzanne/ Podium Floor

2

-

-

... More
Second Floor

2

-

-

... More
Third Floor

2

-

-

... More
Fourth Floor/ Terrace Floor/ Mumty

2

-

-

... More
Providing structural steel work in trusses, other similar trussed purlins and members with all bracing, gusset plates etc. as per detailed designs and drawings or as directed including cutting, fabricating, hoisting, erecting fixing in position, Making riveted/ bolted/ welded connection and one coat of anticorrosive paint and over it 2 coats of oil painting approved quality and shade etc. complete.Ground / Stilt Floor

33

-

-

... More
First/ Mezzanne/ Podium Floor

36

-

-

... More
Providing structural steel work in hollow section of various thickness and sizes in square, rectanular and round shape from 25mm to 450mm section as per IS 4923 YST 310 Grade produced from iron ore and blast furnace route etc. as per detailed designs and drawing or as directed including cutting, fabricating, hoisting, erecting, fixing in position, making riveted/bolted/ welded connections and painting complete.Ground / Stilt Floor

86

-

-

... More
Second Floor

96

-

-

... More
Fourth Floor/ Terrace Floor/ Mumty

24

-

-

... More
Providing and fixing colour coated Zincalume (R) AZ150 (min 150 gms/sq.mt. total on each side) profiled sheets for roofing. The feed material is manufactured out of nominal 0.45 mm Base Metal Thickness (BMT) (0.5 mm TCT), Hi-strength steel with min.550 MPa yield strength, metallic hot dip coated with Aluminium-Zinc alloy (55% aluminium 43.4% zinc 1.6% silicon) with COLORBOND (R) steel quality super durable polyester paint coat (with inorganic pigment). The paint shall have a total coating thickness of nominal 35 um, comprising of nominal 25 um exterior coat on top surface and nominal 10 um reverse coat on back surface. Profile sheet shall have nom. 950-1050 mm effective cover width and nominal 25-30 mm deep ribs with subtle square fluting in the five pan at nominal 180-250 mm center- to-center. The end rib shall be designed for anti-capillary groove. and return leg. The feed material should have coil manufacturers product details marked a regular interval. Including fasteners with min. fastened with min. 25 um Zinc-Tin alloy coated, Hex head, self-drilling screw etc. complete. (weight of profile 4.52 Kilogram/ One Square Metre)Ground / Stilt Floor

1989

-

-

... More
First/ Mezzanne/ Podium Floor

940

-

-

... More
Providing & Fixing in position, Under Deck insulation for metal deck using 1000 Gsm synthetic wool with fixed to deck using adhesive and chicken mesh.First/ Mezzanne/ Podium Floor

780

-

-

... More
Providing and supplying aluminium extruded tubular and other aluminium sections as per the architectural drawings and approved shop drawings , the aluminium quality as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. ( The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account). The weight of aluminium extruded section shall be taken for purpose of payment.

20623

-

-

... More
Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels, including:(a) Structural analysis & design and preparation of shop drawings for the specified design loads conforming to IS 875 part III (the system must passed the proof test at 1.5 times design wind pressure without any failure), including functional design of the aluminum sections for fixing glazing panels of various thicknesses, aluminium cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc., structural and weather silicone sealants, flashings, fire stop (barrier)-cum-smoke seals, microwave cured EPDM gaskets for water tightness, pressure equalisation & drainage and protection against fire hazard including:(b) Fabricating and supplying serrated M.S. hot dip galvanised / Aluminium alloy of 6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3 Dimentional movement for achieving perfect verticality and fixing structural glazing system rigidly to the RCC/ masonry/structural steel framework of building structure using stainless steel anchor fasteners/ bolts, nylon seperator to prevent bimetallic contacts with nuts and washers etc. of stainless steel grade 316, of the required capacity and in required numbers.(c) Providing and filling, two part pump filled, structural silicone sealant and one part weather silicone sealant compatible with the structural silicone sealant of required bite size in a clean and controlled factory / work shop environment, including double sided spacer tape, setting blocks and backer rod, all of approved grade, brand and manufacture, as per the approved sealant design, within and all around the perimeter for holding glass.(d) Providing and fixing in position flashings of solid aluminium sheet 1 mm thick and of sizes, shapes and profiles, as required as per the site conditions, to seal the gap between the building structure and all its interfaces with curtain glazing to make it watertight.(e) Making provision for drainage of moisture/ water that enters the curtain glazing system to make it watertight, by incorporating principles of pressure equalization, providing suitable gutter profiles at bottom (if required), making necessary holes of required sizes and of required numbers etc. complete. This item includes cost of all inputs of designing, labour for fabricating and installation of aluminium grid, installation of glazed units, T&P, scaffolding and other incidental charges including wastages etc., enabling temporary structures and services, cranes or cradles etc. as described above and as specified. The item includes the cost of getting all the structural and functional design including shop drawings checked by a structural designer, dully approved by Engineer-in-charge. The item also includes the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working structural glazing as specified, cleaning and protection till the handing over of the building for occupation. In the end, the Contractor shall provide a water tight structural glazing having all the performance characteristics etc. all complete as required, as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer- in-Charge.Note:- 1. The cost of providing extruded aluminium frames, shadow boxes, extruded aluminium section capping for fixing in the grooves of the curtain glazing and vermin proof stainless steel wire mesh shall be paid for separately under relevant items under this sub- head. However, for the purpose of payment, only the actual area of structural glazing (including width of grooves) on the external face shall be measured in sqm. up to two decimal places.Note:-2. The following performance test are to be conducted on structural glazing system if area of structural glazing exceeds 2500 Sqm from the certified laboratories accreditated by NABL(National Accreditation Board for Testing and Calibration Laboratories), Department of Science & Technologies, India. Cost of testing is payable separately.1. Performance Laboratory Test for Air Leakage Test (-50pa to - 300pa) & (+50pa to +300pa) as per ASTM E-283-04 testing method for a range of testing limit 1 to 200 mVhr2. Static Water Penetration Test. (50pa to 1500pa) as per ASTME- 331-09 testing method for a range up to 2000 ml.3. Dynamic Water Penetration (50pa to 1500pa) as per AAMA 501.01- 05 testing method for a range upto 2000 ml4. Structural Performance Deflection and deformation by static air pressure test (1.5 times design wind pressure without any failure) as per ASTME-330-10 testing method for a range upto 50 mm5. Seismic Movement Test (upto 30 mm) as per AAMA 501.4-09 testing method for Qualitative test, Tests to be conducted on site.6. Onsite Test for Water Leakage for a pressure range 50 kpa to 240 kpa (35psi) upto 2000 ml

1686

-

-

... More
Providing, assembling and supplying vision glass panels (IGUs) comprising of hermetically-sealed 6-12- 6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick, of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade, an inner Heat strengthned clear float glass 6mm thick, spacer tube 12mm wide, dessicants, including primary seal and secondary seal (structural silicone sealant) etc. all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in-Charge. The IGUs shall be assembled in the factory/ workshop of the glass processor.(Payment for fixing of IGU Panels in the curtain glazing is included in cost of item No.25.2)For payment, only the actual area of glass on face # 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in sqm.(i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face # 2, + 12mm Airgap + 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25- 0.28) and U value of 3.0 to 3.3 W/m2 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement.

1359

-

-

... More
Extra for openable side / top hung vision glass panels (IGUs) including providing and supplying at site all accessories and hardwares for the openable panels as specified and of the approved make such as heavy duty stainless steel friction hinges, min 4 -point cremone locking sets with stainless steel plates, handles, buffers etc. including necessary stainless steel screws/ fasteners, nuts, bolts, washers etc. all complete as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer- in-Charge.

463

-

-

... More
Providing, fabricating and supplying shadow box of required size and shape, for fixing in the spandrel portion of the structural glazing, in linear as well as curvilinear portions of the building by providing semi -rigid, inorganic, non-combustible fibre glass wool insulation 50 mm thick, conforming to IS: 8183 and BS: 3958 Part 5. The insulation layer shall have facing (factory bonded on surface # 1 of the fibre glass insulation layer), of black non-woven fibre glass tissue of nominal thickness 0.5 mm and nominal mass not less than 60 gm /sqm, made of randomly oriented glass fibres distributed in a binder by a wet-lay process including fixing 1.5 mm thick solid aluminum sheet backing using, 6 mm thick cement board including SS rivets, nuts, bolts, washers etc complete.

326

-

-

... More
Providing and supplying Spandrel Glass Panels comprising of 6 mm thick heat strengthened monolithic float glass of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade so as to match the colour and shade of the IGUs in the vision panels etc. ,all complete for the required performances as specified, as per the Architectural drawings, as per the approved shop drawings, as specified, and as directed by the Engineer- in- Charge.For payment, only the actual area of glass on face # 1 of the glass panels (but excluding the area of grooves and weather silicone sealant) provided and fixed in position, shall be measured in sqm. (Payment for fixing of Spandrel Glass Panels in the curtain glazing is included in cost of relevent Item*).“(i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face # 2, having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25- 0.28) and U value of 3.0 to 3.3 W/m2 K etc. . The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement.

24

-

-

... More
Supplying and fixing of 6mm thick Exterior Compact Laminate or High Pressure Laminate of approved colour by approving authority with UV resistant Decorative colour paper on both side typically made out of multiple layers of craft papers and then impregnated with thermosetting phenolic resins, on top of it melamine treated barrier paper and decorative paper and wear layer on both the sides saturated with melamine resins and then covered with UV resistant acrylic resin layer which makes it extremely durable and weather resistant compressed together on extremely high pressure and hardened with electron beam curing to get the total desired thickness of 6mm matching European standard specification as per EN 438 -part 6, protected with 60 Micron protective peel-off film on both side which in no case leave any adhesive mark over the panel surface after it is peeled off. Fixing of the same to be done on a supporting frame of 50 mm X 5 mm X 3 mm powder coated aluminium box section to be spaced horizontally and vertically in 600mm X 600mm grid and fixed to building structure as per design through 50mmX50mmX mm 5 mm MS angle bracket prefixed to masonry slab or columns with Hilti make anchor fastener along with all related hardware and fixtures. The panel should then be fixed on the Aluminium section with the help of pure polyester exterior grade colour coating rivets as per architectural drawings or as directed by Engineer-in-charge. Each panel should be riveted on substructure maintaining a gap of 6mm on all the sides between each Panel for Air circulation and expansion and contraction as per installation specifications provided by the manufacturer. The cost shall include all expenses related to storage, material handling, lifting, freight, labour, scaffolding etc as directed by Engineer-in-charge.Ground / Stilt Floor

236

-

-

... More
First/ Mezzanne/ Podium Floor

296

-

-

... More
Second Floor

337

-

-

... More
Third Floor

101

-

-

... More
Fourth Floor/ Terrace Floor/ Mumty

101

-

-

... More
Supply, fixing and installation of 4mm thick Aluminium Composite Panel (ACP) of approved colour for external cladding in combination of solid and metallic colours, including all necessary Framework, support and complete weather sealing as per architectural drawing. The Aluminium Composite Panel (ACP) should be made out of thermoplastic core of low-density polyethylene LDPE (100% virgin mix), sandwiched between two aluminium sheets of ALLOY GRADE- 5000 series, each not less than 0.50 mm thick, total thickness of aluminium composite panels not to be less than 4 mm, the exposed surface thereof shall have Stove lacquered finishing coat not less than (26 + - 2) micron (containing minimum 70% kynar 500 based PVDF) of colour and shade as per architectural design. The inside surface (facing the building exterior surface)shall have polyster based powder coating not less than 25 Micron with protective peel-off foil on the exterior face (peel off film will in no case leave any adhesive mark over the composite panel surface after it is peeled off). The supporting framework shall be made out of 50 mm X25mm X 3mm thick Aluminium section to be spaced horizontally and vertically for fixing of panel of size 900 mm X 1200 mm and fixed to the building structure as per design through 50mm X50mm X5 mm MS angle clamps prefixed to masonry or slab, columns with Hilti make anchor fastener screws. The fixing of panel to be done with the help of VHB tapes and screws and all the sealing of joints to be done with weather sealent Silicon as directed by Engineer-in-charge.Ground / Stilt Floor

915

-

-

... More
Second Floor

1972

-

-

... More
Providing and fixing Glass Reinforced Concrete (G.R.C.) Screens in approved size, pattern, design, shade, colour and thickness of 50mm on frame and design element in 30mm thick having weight approximately between 3.5 – 4 Kg. per Sq.ft. (The above weight and thickness is considering dimensions of screens up to 2133mm in height and 1219mm in width and having at least 50% void space.) The screens should be made from ‘53 grade’ White Portland Cement, Quartz, Fine Silica Sand, Alkali Resistant Glass Fiber manufactured by ‘N.E.G JAPAN’ or equivalent, Super Plasticizers manufactured by ‘ZPXRC’ or equivalent, Polymers manufactured by ‘Dow Chemicals’ or equivalent and U.V resistant Synthetic inorganic pigments should be used for pigmentation manufactured by ‘BAYFERROX / LANXESS (Germany)’ or equivalent. The material casting should take place in FRP moulds. The fixing of Screens should be ‘Dry fixing’ i.e. to be done with M. S. galvanized clamps, fixtures and fasteners of Hilti / Fischer. The work shall be carried out as per specifications, drawing and as per directions of Engineer-in-charge.

152

-

-

... More
Providing and laying machine cut machine Polished Kota stone flooring 25mm to 30mm thick and required width in plain/ diamond pattern on bed of 1:6 C. M. including cement float, filling joints with neat cement slurry, curing, polishing and cleaning etc. complete.Basement Floor/ Under Ground Tank

402

-

-

... More
Ground / Stilt Floor

8619

-

-

... More
First/ Mezzanne/ Podium Floor

4248

-

-

... More
Second Floor

2724

-

-

... More
Third Floor

842

-

-

... More
Providing and fixing in required position skirting or dado of polished Kotah Stone slab 25 mm to 30 mm thick fixed on base on plaster of cement mortar 1:4 including cement float, filling joints with cement slurry, curing rubbing, polishing and cleaning complete.Basement Floor/ Under Ground Tank

16

-

-

... More
Ground / Stilt Floor

689

-

-

... More
First/ Mezzanne/ Podium Floor

453

-

-

... More
Second Floor

347

-

-

... More
Third Floor

109

-

-

... More
Providing and laying machine cut machine polished machine cut Kota stone slabs 20 to 25 mm thick for treads and risers of steps and staircases, with rounded nosing for the treads on a bed of 1:4 cement mortar including cement float, filling joints with neat cement slurry, curing, polishing and cleaning etc. complete.Basement Floor/ Under Ground Tank

60

-

-

... More
Ground / Stilt Floor

718

-

-

... More
First/ Mezzanne/ Podium Floor

490

-

-

... More
Second Floor

355

-

-

... More
Third Floor

143

-

-

... More
Providing Mirror polishing to Kota Stone including using all necessary stones and equipments cleaning, washing etc. complete. For FlooringBasement Floor/ Under Ground Tank

402

-

-

... More
Ground / Stilt Floor

8619

-

-

... More
First/ Mezzanne/ Podium Floor

4248

-

-

... More
Second Floor

2724

-

-

... More
Third Floor

842

-

-

... More
Providing Mirror polishing to Kota Stone including using all necessary stones and equipments cleaning, washing etc. complete. For SkirtingBasement Floor/ Under Ground Tank

292

-

-

... More
Ground / Stilt Floor

7923

-

-

... More
First/ Mezzanne/ Podium Floor

4923

-

-

... More
Second Floor

4043

-

-

... More
Third Floor

1343

-

-

... More
Providing and laying vitrified matt fininsh tiles having size 590 mm to 605 mm x to 605 mm of 8 to 10 mm thickness and confirming IS. 15622-2006 (Group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement morar including neat cement float, filling joints, curing and cleaning etc. complete.Ground / Stilt Floor

9188

-

-

... More
First/ Mezzanne/ Podium Floor

8458

-

-

... More
Second Floor

6334

-

-

... More
Third Floor

2283

-

-

... More
Fourth Floor/ Terrace Floor/ Mumty

1364

-

-

... More
Providing and laying vitrified matt finish tiles having size 590 mm to 605 mm x to 605 mm of 8 to 10 mm thickness and confirming IS. 15622-2006 (Group Bla) of approved make, shade and pattern for dado and skirting in required position fixed in 1:4 cement mortar including neat cement float, filling joints, curing and cleaning etc. complete.Ground / Stilt Floor

6163

-

-

... More
First/ Mezzanne/ Podium Floor

4493

-

-

... More
Second Floor

3195

-

-

... More
Third Floor

937

-

-

... More
Fourth Floor/ Terrace Floor/ Mumty

331

-

-

... More
Providing and laying 18 to 20mm thick Udaipur Green/ jaiselmer Marble of approved quality and colour with machine polished surface, on a bed of cement mortar 1:4 for flooring, sills, riser, dado, window boxing including cement float, filling joints with neat cement slurry to match the colour of the slabs, curing, polishing, nosing/ moulding the sharp edges, cleaning etc. complete.Basement Floor/ Under Ground Tank

23

-

-

... More
Ground / Stilt Floor

541

-

-

... More
First/ Mezzanne/ Podium Floor

245

-

-

... More
Second Floor

114

-

-

... More
Third Floor

32

-

-

... More
Providing and laying 20mm to 25mm thick White marble of approved quality and colour with machine polished surface, on a bed of cement mortar 1:4 for flooring, sills, riser, dado, window boxing including cement float, filling joints with neat cement slurry to match the colour of the slabs, curing, polishing, rounding edges, cleaning etc. complete.Basement Floor/ Under Ground Tank

23

-

-

... More
Ground / Stilt Floor

541

-

-

... More
First/ Mezzanne/ Podium Floor

245

-

-

... More
Second Floor

114

-

-

... More
Third Floor

32

-

-

... More
Providing and laying in position flooring of telephone black / Amba White / Cat bary brown / Ruby red / Ocean Brown granite stone of approved shade and size 18 mm to 20 mm thick on bed 1:6 cement mortar including cement floats striking joints, pointing in C.M. 1:3 curing and cleaning etc. complete.Ground / Stilt Floor

2420

-

-

... More
First/ Mezzanne/ Podium Floor

1079

-

-

... More
Second Floor

646

-

-

... More
Third Floor

178

-

-

... More
Fourth Floor/ Terrace Floor/ Mumty

152

-

-

... More
Providing and fixing machine cut machine polished 18 mm to 20 mm thick telephone black / Amba White / Cat bary brown / RBI red / Ocean Brown granite stone for skirting, treads and risers of steps and staircases of approved colour and shade with full moulding and three grooved line for the treads on bed of 1:4 Cement mortar including float filling joints with neat cement slurry curing polishing and cleaning etc. complete.Ground / Stilt Floor

3885

-

-

... More
First/ Mezzanne/ Podium Floor

603

-

-

... More
Second Floor

423

-

-

... More
Third Floor

148

-

-

... More
Fourth Floor/ Terrace Floor/ Mumty

85

-

-

... More
Providing and laying 18 mm thick Sand ballasted/ Flamed/ Lapatto/ Leather finish Granite stone machine cut in required size, approved shade, color and texture for flooring in required design and patterns, in linear as well as curvilinear portions of the building, treads, landings laid using white cement slurry over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and mirror polishing etc. all complete as specified and as directed by the Engineer-in-Charge.Ground / Stilt Floor

2434

-

-

... More
First/ Mezzanne/ Podium Floor

2079

-

-

... More
Second Floor

242

-

-

... More
Third Floor

139

-

-

... More
Fourth Floor/ Terrace Floor/ Mumty

116

-

-

... More
Providing & laying in position 18 to 20 mm thick mirror polished, machine cut granite stone slabs for kitchen/ pantry/ Lab/ vanity counters & fascias and similar locations of required size of approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement :4 coarse sand) with joints treated with white cement, mixed with matching pigment, epoxy touch ups, including nosing / moulding on free edges and curing etc. complete at all levels.Ground / Stilt Floor

216

-

-

... More
First/ Mezzanne/ Podium Floor

216

-

-

... More
Second Floor

216

-

-

... More
Providing and laying matt finish ceramic tiles of having size 30 cm x 30 cm confirming to I.S.15622/2006 (group D II-A) and 7 to 8 mm thick for flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with white/colour cement slurry cleaning curing etc. complete.Basement Floor/ Under Ground Tank

586

-

-

... More
Providing and laying ceramic tiles having size 30 cm. x 45 cm. confirming to corresponding I.S. for dado and skirting in required position with readymade adhesive mortar of approved quality on plaster of 1:2 cement mortar including joint filling with white/ colour cement slurry cleaning curing etc. complete.Basement Floor/ Under Ground Tank

1869

-

-

... More
Providing and laying cement concrete flooring 50mm thick with M20 cement concrete laid to proper level and slope in alternate bays including compaction, filling joints, marking lines to give the appearance of tiles of 30cm x 30cm or other size laid diagonally/ square etc. finishing smooth (with extra cement) in any colour as directed and curing etc. complete.with Crushed sand VSI GradeGround / Stilt Floor

673

-

-

... More
Providing & fixing in position Stage flooring Made from 18mm plywood 1200 x 2400 & 18mm Teakwood planks 100 x 800 having tongue & grove on Sal-wood frame of 50 x 100 at 600mm c to c on stage surface including cost of required Cut-Outs, decorative mouldings / finishing-items / polish etc., as per Architectural & Acoustical Design & Instructions & Complete in all aspects. .including all materials labour,finishing etc completeGround / Stilt Floor

321

-

-

... More
Stone work (machine cut edges) for wall lining etc. (veneer work) upto 10 metre height, backing filled with a grout of average 12 mm thick cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade : (To be secured to the backing and the sides by means of cramps and pins which shall be paid for separately) :Red sand stone - exposed face fine dressed with rough backing.30 mm thick

900

-

-

... More
Providing and fixing stainless steel cramps of required size and shape for anchoring stone wall lining to the backing or securing adjacent stones in stone wall lining in cement mortar 1:2 (1 cement : 2 coarse sand), including making the necessary chases in stone and holes in walls wherever required.

900

-

-

... More
Providing and fixing copper pins 7.5 cm long 6 mm diameter for securing adjacent stones in stone wall lining in cement mortar 1:2 (1 cement : 2 coarse sand), including making the necessary chases.

1800

-

-

... More
Providing internal cement plaster 12mm to 15mm thick in single coat in cement mortar 1:4 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete.Basement Floor/ Under Ground Tank

370

-

-

... More
Ground / Stilt Floor

45626

-

-

... More
First/ Mezzanne/ Podium Floor

33320

-

-

... More
Second Floor

23072

-

-

... More
Third Floor

9209

-

-

... More
Fourth Floor/ Terrace Floor/ Mumty

4274

-

-

... More
Providing internal cement plaster 6 mm thick in a single coat in cement mortar 1:3 without neeru finish to concrete surface in all positions including scaffolding and curing etc. complete.Basement Floor/ Under Ground Tank

1032

-

-

... More
Ground / Stilt Floor

19161

-

-

... More
First/ Mezzanne/ Podium Floor

15549

-

-

... More
Second Floor

9621

-

-

... More
Third Floor

3920

-

-

... More
Fourth Floor/ Terrace Floor/ Mumty

2290

-

-

... More
Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 mm thick in cement mortar 1:4 using waterproofing compound at 1Kilogramper cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 mm thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc.complete.Basement Floor/ Under Ground Tank

882

-

-

... More
Ground / Stilt Floor

27592

-

-

... More
First/ Mezzanne/ Podium Floor

16843

-

-

... More
Second Floor

9481

-

-

... More
Third Floor

2886

-

-

... More
Fourth Floor/ Terrace Floor/ Mumty

2051

-

-

... More
Providing and fixing chicken mesh of 22 gauge, with about 30 cm. width at the junction of R.C.C members and brick work, of approved quality including fixing mesh in position by necessary drilling in concrete /B.B.masonry and or tying by binding wire etc. complete.Basement Floor/ Under Ground Tank

186

-

-

... More
Ground / Stilt Floor

22816

-

-

... More
First/ Mezzanne/ Podium Floor

16664

-

-

... More
Second Floor

11538

-

-

... More
Third Floor

3517

-

-

... More
Fourth Floor/ Terrace Floor/ Mumty

2138

-

-

... More
Providing and applying Two coats of wall care Putty on plastered surface and Ceiling and Walls to prepare surface even and smooth of approved make, etc complete.Basement Floor/ Under Ground Tank

370

-

-

... More
Ground / Stilt Floor

46321

-

-

... More
First/ Mezzanne/ Podium Floor

36447

-

-

... More
Second Floor

23072

-

-

... More
Third Floor

9209

-

-

... More
Fourth Floor/ Terrace Floor/ Mumty

4274

-

-

... More
Providing and applying priming coat on concrete/ masonary/ Asbestos Cement plastered surfaces including scaffolding if necessary, preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter and sand papering as required etc. complete.Basement Floor/ Under Ground Tank

1402

-

-

... More
Ground / Stilt Floor

64913

-

-

... More
First/ Mezzanne/ Podium Floor

48836

-

-

... More
Second Floor

32690

-

-

... More
Third Floor

13127

-

-

... More
Fourth Floor/ Terrace Floor/ Mumty

6564

-

-

... More
Providing and applying 2 Coats of high quality acrylic copolymer matt approved low VOC emulsion paint of approved shadethat gives smooth, flat and washable and durable finishing of approved make. Paint should have good flow levelling property with good colour retention and incan antibacterial property. Paint has to be applied on smooth and uniform surface prepared by an acrylic copolymer low VOC & Odour putty. This surface should be primed with water based low VOC acrylic copolymer based primer sealer that has incan antibacterial property. The work activity should cover all aspects of applying paints from surface preparation, filling to erecting and dismantling of scaffolding, finishing the surface etc as directed by Engineer in charge.Basement Floor/ Under Ground Tank

1402

-

-

... More
Ground / Stilt Floor

65397

-

-

... More
First/ Mezzanne/ Podium Floor

49320

-

-

... More
Second Floor

33174

-

-

... More
Third Floor

13126

-

-

... More
Fourth Floor/ Terrace Floor/ Mumty

6564

-

-

... More
Providing and applying two coats of exterior acraylic emulsion paint confirming to corresponding I.S. of approved manufacture and of approved colour to the plastered surfaces including cleaning ,preparing the plaster surface, applying primer coat ,scaffolding if necessary , and watering the surface for two days etc complete.Basement Floor/ Under Ground Tank

882

-

-

... More
Providing and applying two coats of exterior weather shield paint of approved manufacture and of approved colour to the plastered surfaces including cleaning ,preparing the plaster surface ,applying primer coat ,scaffolding if necessary, and watering the surface for two days etc complete.Ground / Stilt Floor

27592

-

-

... More
First/ Mezzanne/ Podium Floor

16843

-

-

... More
Second Floor

9481

-

-

... More
Third Floor

2886

-

-

... More
Fourth Floor/ Terrace Floor/ Mumty

2051

-

-

... More
Providing & Fixing in position, Acoustical Ceiling made from perforated gypsum board on approved heavy duty G.I. frame, ceiling channels at 300 c to c, & intermediate channels not more than 1200 c to c, suspended with Hangers from Roof, in front of 1000 Gsm synthetic wool 50 mm thick, with Paint, including cost of required Cut-Outs, decorative mouldings / finishing-items & Scaffolding, as per Architectural & Acoustical Design & Instructions & Complete in all aspects including all materials labour,finishing etc complete.Ground / Stilt Floor

1047

-

-

... More
First/ Mezzanne/ Podium Floor

276

-

-

... More
Providing & Fixing in position, Acoustical Ceiling made from Gypsum Plain Panels on approved heavy duty G.I. frame ceiling channels at 450 c to c, & intermediate channels not more than 1200 c to c, along with ply wood forms suspended with Hangers from Roof, in front of 1000 Gsm synthetic wool 50 mm thick, with Paint, including cost of required Cut-Outs, decorative mouldings / finishing-items & Scaffolding, as per Architectural & Acoustical Design & Instructions & Complete in all aspects.including all materials labour,finishing etc complete.Ground / Stilt Floor

427

-

-

... More
First/ Mezzanne/ Podium Floor

69

-

-

... More
ACOUSTICAL WOODWOOL FALSE CEILING: Providing & fixing of 100% Natural Material- Magnesite (Hygroscopic & biologically sound binding agent) bonded woodwool Heradesign planks of 600Mm*1200Mm *25Mm thickness made out of wood wool fiber of width 1Mm Fiber thickness mixed with Natural water & Magnesite (No-Cement) with open & smooth surface texture, Weight of panel to be 11.3 Kg/m2. A Completely harmless Environment & Human Friendly & also a disposable or recyclable Material & can last for more than 80 Years in building interiors As it has long lifespan & suitable for Indoor conditions with relative air humidity of upto 90%. Magnesite protects the wood cells against ageing & fungal attack. To achieve upto NRC=1.00 it should be a clear gap of 200Mm from wall slab along with the backing of Mineral wool of 50mm thick with 64 kg/m3 density. Ecologically Sound Material with high mechanical strength with Crash test of 90Km/H with Ball Impact Test DIN18032 & EN13964 with flying colors & A sustainable material (PEFC & FSC Certified) along with EPD Certified Acc. to EN ISO 14025 (AUB-Environmental Product declaration). Manufacturing tolerance for nominal size: Length, Width & Thickness ± 1 mm, & In a Standard Climate of 23° C and 50% rel. humidity. FIXING & SUBSTRUCTURE: Impact Resistant According to DIN-18023 or EN13964 to be Fixed on CD Sections Profile framework with Screw 9Pc/Panel & Centre Distance Support of 300Mm & Centre distance of Cross Profile would be at 600Mm & Main Profile at 900Mm CD Profile is made out of GI( Sections Profile 60/27/0.6Mm-0.6MmThick x 60Mm Width x 0.27Mm height). The Main Profile is in the length of 3000mm & to form a section of 600mm x 1200mm. The CD Profile is to be suspended from soffit with the help of nonius hanger at a center distance of 900mm. UD Profile 28/27/0.6mm to be fixed on wall at the perimeter of the wall. If the main CD profile needs to extended, it needs to be connected with CD profile connector 60/27. The CD profiles to be connected to each other at the intersection by CD cross connector. Heradesign Superfine panels to be fixed to the ceiling with a minimum of 200mm void or gap with Galvanized screws of length 50Mm & Dia 4.5Mm with a backing of Mineral Wool of density 64kg/m3 density (50mm thick). Colour pf Panels : NATURAL BEIGE, Can be Painted to the desired colour (Any- RAL, NCS or StoColor Shades) using water based color by Spray method prior to installation. FIRE CLASS as per EN 13501-1:B –s1, d0. Test Certificates to be submitted. Ground / Stilt Floor

300

-

-

... More
Providing and fixing false ceiling with eco-friendly light-weight calcium silicate tiles of spintone surface texture aerolite make or equivalent of size 595mm x 595mm having 15mm thick densified micro look edge and 100% humidity resistance incombustible as per BS 46part IV and thermal conductivity 0.043 w/m 0 KC and NRC 0.50 placed in true horizontal level suspended grid of size 600x600mm made from hot dipped G.I. steel sections ion silhouette profile, rotary stitched double webbed white with 6mm reveal profile (white/black), wherein, main T runner of size 42mmx14mm between main tee 600mm center-tocenter and secondary cross T of size 33x14x0.43mm thick of length 600mm long spaced inter-locked at middle of the first crossed T in each panel to form grid of 1200mmx600mm resting on periphery wall Profile wall section 19mm (7+7) x 19mmx0.40thicknesses and laying false ceiling for services like diffusers grills including cutting, making opening for light fittings, fixtures, , smoke detectors etc., wherever required. Main T runners suspended from ceiling with using G.I. soffit cleats of size 25x35x1.6 mm of required length fixed to the ceiling with 6mm dia and 50mm long dash fastener, 4mm dia G.I. adjustable rods with powder- coated/good quality G.I. level adjustment clips of 35x35x0.8mm spaced @1200, center-to- center along main T all complete at all heights as per the specifications, drawings complete.Ground / Stilt Floor

531

-

-

... More
First/ Mezzanne/ Podium Floor

388

-

-

... More
Second Floor

388

-

-

... More
Providing and fixing in position Gypsum board false ceiling with 12.5 mm thick Gypsum boards, screwed/fixed to the under structure of suspended G.I. Grid constructed and suspended from the main ceiling consisting of ceiling sections of size 25 x 50 mm maximum center to center distance of 600 milimetre perimeter channel and intermediate channels at maximum center to center distance 1200 milimetre galvanized grid should be fixed to reinforced cement concrete slab. The gypsum board should be fixed to galvanized iron grid with necessary screws. The boards should be taped and filled from underside to give smooth, seamless ceiling. The rate should include necessary additional ceiling sections and intermediate channels. Additional intermediate channels should be fixed to strap hangers for additional support to prevent strapping at every 1200 milimetre item to be completed in all respect including necessary sleeves for ducts finishing of joints cut outs, painting including labour, material, lifts etc. all complete.Ground / Stilt Floor

455

-

-

... More
First/ Mezzanne/ Podium Floor

98

-

-

... More
Second Floor

98

-

-

... More
ACOUSTICAL WALL PANELLING – FABRIC WRAPPED OF SIZE: 600X600/1200X25MMProviding and Fixing of Acoustical Wall Panel with square edges made of fibre glass substrate 25mm thick, wrapped on the front side with an acoustically transparent fabric as per the approved shade (Husk, Copper, Sangria, Sesame, Coffee, Charcoal, Titanium, Flame, Peanut and Shell). The panel shall be classified for Fire Class A, as per ASTM E-84. The Acoustical Wall Panel shall be of sizes 600x600mm (Nominal) or 600x1200mm (Nominal) and shall achieve an NRC of 0.85 (Average value of Absorption Co-efficient readings taken at 250 Hz, 500 Hz, 1000 Hz and 2000 Hz) with 50mm airgap as per ASTM C423 to be fixed to wall on a framework of wooden battens and using Wall panel Impalers (supplied by the manufacturer) or by using construction adhesives (as per the instructions laid down by the manufacturer). The fibre glass substrate shall have a recycle content of 85%. Installation:An appropriate vapour barrier (by others) shall be applied/installed on the vertical surface before the installation to properly seal against entry of any moisture. Vapour barrier (by others) shall be installed as per Manufacturer’s recommendation. Install wooden batten grid (provided by others) of section 50x50mm or as approved by the Architect on the solid wall/partition to provide level and plumb surface. The Impalers shall be fixed to the battens using self-tapping screws, 3 nos. in case of 600x600mm and 4 nos. in case of 600x1200mm. Silica based construction adhesive (by others) to be dabbed on to the projecting elements (spikes) of the Impalers. Wall Panels shall be pierced through the spikes of the Impalers ensuring the line and level of the panels are maintained.Ground / Stilt Floor

620

-

-

... More
First/ Mezzanne/ Podium Floor

216

-

-

... More
CHANNELLED WALL PANELLING OF SIZE: 192X2400X15MMProviding and Fixing Channelled perforated panels of width 192mm, thickness of 15mm and length 2400 mm, made of a Moisture resistant fibre board substrate with a laminated facing as per the approved shade (Portland Maple, Sea Beech, Siam Wood & Mystique Walnut, Interior White, Alumina Pearl) and a melamine balancing layer on the reverse side. The boards shall have a special perforation pattern where the reverse surface has a “Helmholtz” fluted perforation with consecutive 3mm wide groove followed by 13mm or 21mm of visible pane (G-13/ G-21). The edges of the panel shall be “tongue-and-grooved” to fix special clips for installation and seamless visual. The back of the perforated panel shall have sound absorbing non-woven Soundtex acoustical fleece hot pressed to achieve NRC of 0.5. for G-21 and 0.6 for G-13. (Average value of Absorption Co-efficient readings taken at 250 Hz, 500 Hz, 1000 Hz and 2000 Hz) as per ASTM C423 and Humidity Resistance (RH) of 70% with camber limit less than 1mm/1000mm and bow less than 1mm/300mOne Metric Tonnehe panels shall be mounted on special aluminium splines (keel) using inside clips provided by Manufacturer and approved by the Architect/ Engineer-in-Charge.Installation: An appropriate vapour barrier (by others) shall be applied/installed on the vertical surface before the installation to properly seal against entry of any moisture. Vapour barrier (by others) shall be installed as per Manufacturer’s recommendation. Install wooden batten grid (provided by others) of section 50x50mm or as approved by the Architect on the solid wall/partition to provide level and plumb surface for fixing Keel. Install Keel vertically using screws and plugs at spacing of not more than 600mm centre-to-centre. The first and last keel should not be more than 150mm from the ends. Trim the tongue of the first bottom panel and install using headless nail with groove side upward. Subsequent panels are installed with tongue side downward by engaging with each other using tongue and groove mechanism and secured by inside clip. Continue this process until required height is achieved. Shorter butt edges need to be joined using industrial/wood glue. The keel shall also be used for transition of the butt end of adjacent panel at every 7.2m. Install the Skirting (provided by others) of width 50mm or more as required by the Architect/ Engineer-in-Charge. Finish off the edges using wooden moulding of matching colour (by others). Installation should be carried out as per Manufacturer recommended procedure. Ground / Stilt Floor

335

-

-

... More
First/ Mezzanne/ Podium Floor

158

-

-

... More
ACOUSTICAL WOODWOOL WALL PANELLING: Providing & fixing of 100% Natural Material- Magnesite (Hygroscopic & biologically sound binding agent) bonded woodwool Heradesign planks of 600Mm*1200Mm *25Mm thickness made out of wood wool fibre of width 1Mm Fiber thickness mixed with Natural water & Magnesite (No-Cement) with open & smooth surface texture, Weight of panel to be 11.3 Kg/m2. A Completly harmless Envirenment & Human Friendly & also a disposable or recyclable Material & can last for more than 80 Years in building interiors As it has long lifespan & suitable for Indoor conditions with relative air humidity of upto 90%. Magnesite protects the wood cells against ageing & fungal attack. To achive upto NRC=1.00 it should be a clear gap of 200Mm from wall slab along with the backing of Mineral wool of 50mm thick with 64 kg/m3 density. Ecologically Sound Material with high mechanical strength with Crash test of 90Km/H with Ball Impact Test DIN18032 & EN13964 with flying colors & A sustainable material (PEFC & FSC Certified) along with EPD Certified Acc. to EN ISO 14025 (AUB-Envirenmental Product declaration). Manufacturing tolerance for nominal size: Length, Width & Thickness ± 1 mm, & In a Standard Climate of 23° C and 50% rel. humidity. FIXING & SUBSTRUCTURE: Impact Resitant According to DIN-18023 or EN13964 to be Fixed on CD Sections Profile framework with Screw 9Pc/Panel & Centre Distance Support of 300Mm & Centre distance of Cross Profile would be at 600Mm & Main Profile at 900Mm CD Profile is made out of GI( Sections Profile 60/27/0.6Mm-0.6MmThick x 60Mm Width x 0.27Mm height). The Main Profile is in the legth of 3000Mm & to form a section of 600mm x 1200mm. Heradesign Superfine panels to be fixed on the wall with a minimum of 200Mm void or gap with Galvanized screws of length 50Mm & Dia 4.5Mm with a backing of Mineral Wool of density 64kg/m3 density (50mm thick).Colour Of Panels : NATURAL BEIGE, Can be Painted to the desired colour (Any- RAL, NCS or StoColor Shades) using water based color by Spray method prior to installation. FIRE CLASS as per EN 13501-1:B –s1, d0. Test Certificates to be submitted. Ground / Stilt Floor

305

-

-

... More
Providing & Fixing in position, Acoustical panelling made from perforated gypsum board on 50 x 50 mm Sal-wood frame of 600 x 600 c to c having wooden supports from wall of required length, in front of 1000 Gsm synthetic wool 50 mm thick with chicken mesh on wall side, including cost of required Cut-Outs, decorative mouldings / finishing-items / paint & Scaffolding, as per Architectural & Acoustical Design & Instructions & Complete in all aspects. including all materials labour, finishing etc complete. Ground / Stilt Floor

755

-

-

... More
First/ Mezzanne/ Podium Floor

216

-

-

... More
Providing & Fixing in position, Acoustical Panelling made from Gypsum plain 12mm panels on, 50 x 50 mm Sal-wood frame of 600 x 600 c to c having wooden supports from wall of required length, in front of 1000 Gsm synthetic wool 50 mm thick with chicken mesh on wall side, including cost of required Cut-Outs, decorative mouldings / finishing-items / paint & Scaffolding, as per Architectural & Acoustical Design & Instructions & Complete in all aspects. including all materials labour,finishing etc complete. Ground / Stilt Floor

277

-

-

... More
First/ Mezzanne/ Podium Floor

108

-

-

... More
Construction of granular sub-base by providing close graded Material, mixing in a mechanical mix plant at OMC, carriage of mixed Material to work site, spreading in uniform layers with motor grader / Paver on prepared surface and compacting with vibratory roller to achieve the desired density, complete as per clause 401 -- Plant Mix Method and Grading - II Material

4728

-

-

... More
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing to proper grade and camber, applying and brooming requisite type of screening/ binding Materials to fill up the interstices of coarse aggregate, watering and compacting with Vibratory roller. to the required density. By Mechanical Means - Grading I (Using Screening Type A (13.2) mm Aggregate)

4301

-

-

... More
Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate ( natural sand/ VSI grade finely washed crushed sand) conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, , cement content not to be less than 150 kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant/ Weigh batch mixer, transported to site with all leads and lifts, laid with a paver with electronic sensor /by suitable means as approved by Engineer-in-charge , compacting with vibratory roller, finishing, curing and including preparation of sub-grade surface if required etc. complete. with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete.

5418

-

-

... More
Providing and laying in situ cement concrete M -30 with tremix treatment for 200 mm thickness for Concrete Road is including laying plastic sheet for 125 micron thickness with groove cutting of 4 mm wide and 20 mm deep with necessary refilling with polysuphide sealent (Pouring grade) confirming to BS : 5212 - 1989 into sawed groove widened at top for sealent reservoir of specified size and shape as per detailed drawing including fixing Polyethylene foam backer rod of required diameter ( excluding reinforcement) with coarsen and fine aggregate Using V.S.I.Quality Artifitial Sand etc. complete with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete.

2843

-

-

... More
Providing and applying Cold plastic paint two component rolled on surfacing material solvent free,high build two pack seamless,tough,skid resistant,material with has property of attaining 2.00mm thickness in single coat application white(or as required colour )based on glass and colour retaining acralic cross linking resin system for coloured road surfacing including surface cleaning and cost of all material etc. complete. (All inclusive on bitumen or concrete surface) work shall carried out as per IRC 35-2015 clause 2.2)

711

-

-

... More
Prime coat - Providing and applying primer coat with bitumen emulsion on prepared surface of granular Base including cleaning of road surface and spraying, primer at the rate of 0.60 kg/sqm using mechanical means.

1782

-

-

... More
Providing and applying tack coat on the prepared surface heating by fames in Boiler and spraying bitumen with sprayer on Dry / Hungry B.T. surface 3 kg/10 sqm. (VG-30 bulk bitumen rates are considered to arrive at rates)

1782

-

-

... More
BITUMINOUS CONCRETE:--Providing and laying bituminous concrete using crushed aggregate of grading 1, premixed with bituminous binder @5.40% by weight of total mix and filler, transported at site with VTS, laid over a previously prepared surface, finished to the required grade ,level, alignment, and rolling to achieve the desired density for 50mm compacted thickness with drum mix plant with SCADA, Sensor paver and Vibratory roller excluding prime/Tack coat etc. complete --Bitumen of specified grade with stone dust filler. (VG-30 bulk bitumen rates are considered to arrive at rates)

133

-

-

... More
Providing and casting in situ or precast tapering R.C.C. M-20 Barrier type Kerb with gutter ( as per IRC 86 1983) embedded 125mm below ground level over M-10 PCC finished neatly with C.M. 1:2, setting the same in C.M. 1:2, including the required excavation in any strata and removing the excavated stuff any where in city and redoing the surface as specified and directed by Engineering In-charge. Using Concrete Batching and Mixing Plant

9989

-

-

... More
Providing and Laying factory made coloured chamfered edge Cement concrete grass paver blocks of required strength,thickness & size/shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of fine fine aggregate (natural sand/crushed sand VSI grade finely washed etc.), compacting and proper embedding/laying of inter locking paver blocks into the fine aggregate (natural sand/crushed sand VSI grade finely washed etc.) bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine aggregate (natural sand/crushed sand VSI grade finely washed etc.) and cutting of paver blocks as per required size and pattern, finishing and sweeping extra fine aggregate (natural sand/crushed sand VSI grade finely washed etc.) and complete as per manufacturer spsecifications & direction of Engineer-in-Charge. 60mm thick CC paver block of M-35 grade concrete with approved colour and design & pattern.

1020

-

-

... More
WATERPROOFING FOR RAFT: Supplying and installing 1.5 mm composite thick fully bonded weldable HDPE membrane conforming to IS 16471:2017 requirements of UG waterproofing structures, requirements to provide Type A fully bonded protection of UG waterproofing structures. The membrane shall exhibit 25 years of service life tested and complied in accordance with EN 13251:2016 durability certification. The membrane should be minimum 2.4 m wide comprising of an HDPE layer and a pressure sensitive adhesive layer which is covered by a weatherproof protective layer with lap Joint Strength at overlaps 15000 N/m ASTM D 6392:2012. The membrane shall have minimum of 100 mm side and end laps which shall be thermofused with leister machines at all the joints for assuring watertightness and achieving monolithic membrane. End laps and side laps should be a minimum of 100 mm with the weld size of minimum 60 mm in case of a single weld system. In case of a double weld system, comprising of two parallel welds of 20 mm wide each with a 20 mm air channel gap in between the two weld lines.The size of the membrane should not be less than 2.4 Mtr. x 20 Mtr. to minimize the joints. This membrane shall be continued over the vertical surface but terminated minimum 100mm below the top edge of the raft slab/footings and fixed, etc all complete as per specifications & instructions of Engineer in Charge.

1130

-

-

... More
Providing and fixing Swellable water stop 20 X 10mm at construction joint at junction of raft and retaining wall. Providing and applying water swellable bar at starter & all construction joints, of size of minimum 20mm X 5mm, it shall have resistance to deterioration from salt water, volumetric expansion 200%, Elongation 400%, Shore A Hardness 35, Tensile strength 2 Mpa, Temperature resistance : (-) 20 to +75 deg C, Water head resistance 50 m. It shall be fixed to the concrete using a gun grade hydrophilic adhesive / or mechanically fixed by binding wire with steel reinforcement, as recommended by manufacturer. Later post construction, groove cutting of the construction joints 25mm X 25mm size internally / externally, cleaning with compressed air and thereafter filling with Polymer modified cementitious mortar, all as per manufacturers recommendations etc all complete as per specifications & instructions of Engineer in Charge.

1473

-

-

... More
WATERPROOFING FOR RETAINING WALL: Providing and laying 1.5 mm thick SBS based self-adhesive waterproofing membrane topped with HDPE cross laminated valeron film with the following technical properties-Softening point of 105 (oC) as per ASTM D36 ,Tensile Strength (L/T)- 3.5 N/sq.mm as per ASTM D412,Elongation (L/T) L- 180 % ,T -180% as per ASTM D 412, Puncture Resistance- 200 N as per ASTM E 154, Hydrostatic pressure 60 m (6BAR) No leakage as per DIN 1048, including cleaning the surface and removal of flaky materials ,grouting the porous areas with cementitious grout, proper coving(50 mmx 50mm)at sharp edges of concrete and priming the surface with cold applied bituminous primer @150 gm /sq.mtr. The SBS membrane should be sealed properly at joints and maintaining 75 mm overlap between the membrane selvedge & 100 mm overlap on the end joints of the membrane over the slab etc. complete . Termination: The membrane shall be terminated at 300 mm above the Finished floor level by applying aluminum strip flashing with fasteners at the top and sealing the joints with PU sealant. etc all complete as per specifications & instructions of Engineer in Charge.

885

-

-

... More
Providing & Fixing of protection board 8MM HDPE Dimple board spot bonded on retaining wall before backfilling etc all complete as per specifications & instructions of Engineer in Charge. .

885

-

-

... More
Providing aluminum flashing, wherever required for termination of self dhesive membranes at all locations. Item shall include rates for membrane termination on the Vertical retaining wall at height 300mm above the ground level for termination of the membrane and finally sealing the strip using Polysulphide sealant etc all complete as per specifications & instructions of Engineer in Charge.

220

-

-

... More
Base preparation of cleaning, brushing and removal of any loose/flacky materials, in case of pot holes/cracks, the same shall be repaired with polymer modified cement mortar using SBR Latex.Supplying and applying 10 mm thick, two components instant setting spray applied polyurethane Waterproofing system,polymeric closed cell PU Foam with a core density of 45-50kg/cu.mt as per ASTM D1622. The cured foam should behaving closed cell apparent of 96%-98% by volume as perASTM D-2856, thermal conductivity of 0.029W/MK as per ASTM C-518/91 and having fire resistance properties conforming to class B2 as per DIN4102 as per the manufacturer's recommendations.Supplying and apply single component cold applied polyurethane elastomeric coating having solid content 90% as per ASTM C836,elongation at break 400% ASTM D-612, hardness 75 shoreA, as per ASTM D2240 @1 kg/m2, brush applied waterproofing coating, on top of cured PU foam systemSpreading120 gsm Geotextile (non woven polyester).Supplying and applying slope making and protection to the waterproofing treatment with 75mm avg. thick M20 grade screed (Screed should be paid in separate in DSR item no 22.14.1 (S.No. 40) All around on the roof, at the parapet wall junction, an angular fillet of 50 mm X 50 mm shall be made in cement-sand mortar in 1:3 proportion. The concrete shall be exposed by cutting grooves of size 6mm(W) x35mm(D) by saw cutting into panels of size 3 x 4mtrs,the grooves formed by exposing the concrete shall be filled with polysulphide sealant. (Terrace waterproofing)

21976

-

-

... More
Providing water proof bedding for flooring of Bath and W.C. 25 mm thick in C.M. 1:3 including using approved water proofing compound in specified proportion as per manufacturers specifications for per bag of cement including leveling, curing and covering 10 years guarantee on court fee stamp paper of Rs.500/- including ponding test etc. complete. (As directed by Engineer in charge) First/ Mezzanne/ Podium Floor

2346

-

-

... More
Second Floor

1718

-

-

... More
Third Floor

592

-

-

... More
Fourth Floor/ Terrace Floor/ Mumty

317

-

-

... More
Providing and applying two component polymer based cementitious waterproofing system in following sequence;Cleaning the internal surface areas thoroughly so that they are free of all contaminants like dirt and laitance & to remove all the loose materials by various mechanical means.Removal of all surface imperfections, protrusions,loose concrete & filling of cracks using SBR latex Modified Mortar in the ratio Cement: Sand (1:4) and 5% by weight of cement.Providing & grouting at construction joints cementitious grout into each nozzles( 1 mtr c/c) at regular intervals as per the requirements.Providing and making fillets at the junction of the walls and the slabs using cement mortar of 1:4 mix admixed with 5 % of SBR latex by weight of cement.Applying 3 coats of 2 component, prepacked,polymer modified cementitious coating of tensile strength of 1.0 N/Sq.mm as per ASTM D 412,elongation of 120% as per ASTM D 412 ,crack bridging of 2mm as per ASTM C836,applied @ 3kg/sq.mtr all over the slab including the angular fillets and extendable over the vertical walls .Finally sprinkling sand over the third coat for better adhesion with plaster. The interval between each coat of coating application is 6-8 hrs.Providing & laying a protection layer of 20 mm thick cement mortar (1 cement :4 Coarse sand) admixed with integral waterproofing compound as per IS 2645Providing & applying two coats of antibacterial antifungal food grade epoxy coating at a consumption of 3 Sq.mtr/kg as per CFTRI 21 CFR 175 - 300 of US - FDA , Water absorption nil as per ASTMC 870:90, adhesion strength of 2.5 N/mm2 as per ASTM D4541:02 applied with an interval of 6-8 hrs between each coat over the cured plastered surface as per manufacturer’s instruction. (UGWT & OHT )

2705

-

-

... More
Trenching in ordinary soil up to a depth of 60 cm including removal and stacking of serviceable materials and then disposing of surplus soil, by spreading and neatly leveling within a lead of 50 m and making up the trenched area to proper levels by filling with earth or earth mixed with sludge or / and manure before and after flooding trench with water (excluding cost of imported earth, sludge or manure).

100

-

-

... More
Supplying and stacking of good earth at site including royalty and carriage upto 5 km complete (earth measured in stacks will be reduced by 20% for payment).

100

-

-

... More
Supplying and stacking at site dump manure from approved source, including carriage upto 5 km complete (manure measured in stacks will be reduced by 8% for payment) :Screened through sieve of I.S. designation 4.75 mm

5625

-

-

... More
Rough dressing the trenched ground including breaking clods

75000

-

-

... More
Spreading of sludge, dump manure and/or good earth in required thickness as per direction of officer-in-charge (cost of sludge, dump manure and/ or good earth to be paid separately).

5625

-

-

... More
Plantation of Trees, Shrubs, and Hedge at site i/c watering and removal of unserveiceable material’s as per direction of officer in charge.

500

-

-

... More
Flooding the ground with water including making kiaries and dismantling the same.

75000

-

-

... More
Providing & laying Selection no. 1 grass turf with earth 50mm to 60mm thickness on existing ground prepared with proper level and ramming with required tools wooden and than rolling the surface with light roller make the surface smoothen and light watering the same, as per direction of officer in charge

75000

-

-

... More
Stone work (machine cut edges) for wall lining etc. (veneer work) for all height in required design and patterns in linear as well as curvilinear portions of the building, all complete as per the architectural drawings, backing filled with a grout of average 12 mm thick cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade.Delhi quartzite stone 75mm thick hand cut

2315

-

-

... More
Extra for providing bush hammered/ leather finish/ shot blasted finish to granite stone in required design and patterns, bands in linear as well as curvilinear portions of the building, all complete as per the architectural drawings

503

-

-

... More
40 mm thick rubbed stone flooring over 20 mm (average) thick base of cement mortar 1:5 (1 cement : 5 coarse sand) with joints 3 mm thick, side buttered with cement mortar 1:2 (1 cement : 2 stone dust) admixed with pigment to match the shade of stone and pointing with same mortar.Red sand stone

957

-

-

... More
Providing and fixing factory made Hydraulically pressed Mechanically vibrated and compacted precast inter locking cement concrete paving blocks 80MM thick in M-40 grade of approved size and shape for City streets, small /medium market roads,low volume roads, utility cuts on arterial roads etc. as specified and as per IS 15658:2006 including cost of all materials, manufacturing, curing, transportation of blocks to work site including loading, unloading and stacking as directed, laying paving blocks in position over prepared bed of natural sand / crushed sand of 50 mm thickness including necessary excavation in all stratas, spreading blindge of fine sand over the prepared bed, compacting blocks by plate vibrator etc. complete.

9180

-

-

... More
Providing and fixing 10x10x7.50 cm Granite stone block hand cut and chisel dressed on top, for paving in floors, drains etc. laid over 20mm thick base mortar 1:4 (1 cement : 4 coarse sand) with joints 10mm wide filled with same mortar including ruled pointing etc. complete as per direction of engineer-in-charge.

12799

-

-

... More
Providing & laying 8 layer Acrylic cushion system consisting of 1st layer of primer to improve bonding of acrylic paint with subfloor, 2nd layer Acrylic Re-surfacer 367-30 for filling and smoothing subfloor followed by Triple layer of Uni-rubber cushion, 6th & 7th layer 100% acrylic latex based textured tennis base colour coat & 8th finished top colour coat to protect flooring against UV rays including cost of overline marking with Acrylic paint complete in all respect as per specification of manufacturer.

1782

-

-

... More
Providing and Fixing vitreous china floor mounted (European Type) water closet with 'P" or "S" trap, C.P. bolts, nuts with solid plastic seat & lid, C.P brass hinged rubber buffers with dual flush 3/6 litre capacity cistern with flush pipe, clamp and rubber adapter joint C.P.brass screws and washers complete including cutting and making good the walls and floors wherever required etc. complete in all respect as per direction of Engineer-in-charge.(Make- Euronics: Model No.C001-WC)(Make- Jaquar: Model No.LYS-WHT-38751S250UFSM)(Make- Hindware: Cat. No.: 92597)

72

-

-

... More
Providing & fixing white vitreous china wall hung type European type water closet and internal fittings with C.P. bolts, nuts, C.I. chair or other hanging arrangement, with white solid plastic seat and cover with lid, C.P. brass hinge rubber buffers, with accessories,C.I/M.S. brackets painted with two or three coats of enamel paint of approved shade over a coat of primer. C.P. brass screws and wooden cleats, including cutting and making good the wall and floors wherever required ((Make- Euronics: Model No.C003-WC)(Make- Jaquar: Model No.ARS-WHT-39953BIUFSM)(Make- Hindware:Cat. No.: 92610)

519

-

-

... More
Providing and Fixing Concealed Flushing Cistern with dual flush Actuator, flush-stop function, noise less float valve and fast filling action with all component parts of high quality With Flash Plate complete including fixing frame and set. ((Make- Geberit: Model No.109.011.00.1)((Plate Make- Geberit: Model No.115.045.11.3)(Make- Jaquar: Model No.JCS-WHT-2431)(Make- Hindware: Cat. No. 518236)

591

-

-

... More
Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm sand cast Iron P or S trap, 6 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required etc. complete in all respect as per direction of Engineer-in-charge.White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests

10

-

-

... More
Providing and Fixing White vitreous china Under counter wash basin with C.I. brackets painted white, 15 mm CP Brass auto closing pillar cock, 32mm dia. C.P. waste, C.P chain and rubber plug, C.P. connecting pipe to wall and C.P wall flange and rubber adapter for waste connection complete including cutting and making good the walls wherever required etc. complete in all respect as per direction of Engineer-in-charge.((Make- WB Euronics: Model No.C016-WB)((MakeSelf Closing Tab- Euronics: Model No.EPT04B-CP)

257

-

-

... More
Providing and Fixing White vitreous china over the counter wash basin with C.I. brackets painted white, 15 mm CP Brass auto closing pillar cock, 32mm dia. C.P. waste, C.P chain and rubber plug, C.P. connecting pipe to wall and C.P wall flange and rubber adapter for waste connection complete including cutting and making good the walls wherever required etc. complete in all respect as per direction of Engineer-in-charge.(Make- WB Euronics: Model No.C005-WB) ((Make Basin Pillar Cock- Euronics: Model No.RIV-1014R)

334

-

-

... More
Providing and fixing vitreous china urinal with electrical/ battery operated concealed automatic flushing system CP Brass body with C.I. hangers, 15mm dia inlet to built in spreaders with inbuilt waste with C.P flange for urinal complete including cutting and making good the walls and floors wherever required etc. complete in all respect as per direction of Engineer-in-charge. (Make- Euronics: Model No.C020-UR,Sensor Model-EU44BE)

93

-

-

... More
Providing and fixing kitchen sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P. brass waste complete, including painting the fittings and brackets, cutting and making good the walls wherever required:Stainless Steel sink of size 600x450x 250mm

58

-

-

... More
Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required :Size 600x450x200 mm

12

-

-

... More
Providing and fixing 15mm nominal bore C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms.(Make- Euronics: Model No-RIV-1010R)

42

-

-

... More
Providing and Fixing C.P. brass towel ring "Round" fixed to PVC cleats with C.P. brass screws including cutting and making good the walls wherever required etc. complete in all respect as per direction of Engineer-in-charge.(Make- Euronics: Model No-ACC03)

220

-

-

... More
Providing and fixing SS liquid soap dispenser with push lever assembly with soap refill fixed in wall with Screws complete in all respect as per direction of the engineer-in-charge.(Make- Euronics: Model No-ES05)

174

-

-

... More
Providing and fixing CP Brass Bottle Trap of approved quality & make etc. complete in all respect as per direction of Engineer-in-charge. 32 mm dia (Make- Euronics: Model No-EBT32-CP)

777

-

-

... More
Providing and fixing C.P. brass angle valve for basin and geyser points of approved quality conforming to IS:8931 15mm nominal bore. (Make- Euronics: Model No-RIV-1003R)

2662

-

-

... More
Providing and fixing C.P. Brass Toilet paper holder, including cutting and making good the walls wherever required etc. complete in all respect as per direction of the Engineer-in-charge. (Make- Euronics: Model No-RIV-ACC08)

591

-

-

... More
Providing and fixing Health faucet with 1 metre long Flexible Tube and CP wall hook with PVC & SS Screws wherever required complete as directed by the Engineer-in-charge. (Make- Euronics: Model No-EHF01)

588

-

-

... More
Providing and fixing two way bib cock complete, including cutting and making good the walls wherever required etc. complete in all respect as per direction of Engineer-in-charge. (Make- Euronics: Model No-RIV-1004R)

594

-

-

... More
Providing and Fixing Handicapped set including white vitreous china floor mounted European type water closet including exposed cistern , Flat Back wash basin with one pair of mounting brackets , complete with fittings, seat cover, two no hinged rail 76 cms and five nos of grab bar 60 cms including 15 mm dia autoclosing pillar cock for Handicaped Toilet complete in all respest as per direction of the engineer-in-charge.

12

-

-

... More
Providing and Fixing CP auto push cock with CP Wall flange for drinking water purpose complete as per direction of the engineer-in-charge. (Make- Euronics: Model No-EPT05 )

36

-

-

... More
Providing and Fixing wall mounted CP brass sink mixer with Swinging casted spout of required size with 450 mm long copper pipe with nuts and rubber washer including cutting and making good the walls wherever required (Make- Euronics: Model No-RIV-1020R )

62

-

-

... More
Providing & fixing C.P. brass single lever basin mixer without pop up waste system with 450mm long Copper Pipes with nuts and rubber washer including cutting and making good the walls wherever required (Make- Euronics: Model No-RIV-1021R )

594

-

-

... More
Providing and Fixing C.P cast brass double coat hook fixed to PVC cleats with C.P. brass screws including cutting and making good the walls wherever required (Make- Euronics: Model No-RIV-EC02)

594

-

-

... More
Providing and Fixing complete system of Bath and Shower with concealed DivertorSingle lever concealed divertor With Exposed finish plate for Bath and Shower (Make- Euronics: Model No-RIV-AL005D,RIV-1017R)

303

-

-

... More
Overhead shower round with Arm shape single flow (Brass body) with shower Arm casted.(Make- Euronics: Model No-RIV-AL005D,RIV-1AL021),

303

-

-

... More
CP Bath Spout with wall flange 225 mm long (Make- Euronics: Model No-RIV-1008R

303

-

-

... More
Providing and Fixing CP Soap dish with PVC plugs with screws and making good the walls wherever required (Make- Euronics: Model No-ACC01

232

-

-

... More
Providing and Fixing 600 mm long Hand rail (Grab bar) for Handicap Toilets with Stainless Steel Screws on wooden cleats complete as per instructions of the engineer-in-charge (Make- Euronics: Model No-EGR01(600MM)

12

-

-

... More
Providing and Fixing C.P. Sliding Rail with stainless steel screws on plastic cleants complete in all respects as per the Engineer- In -charge (Make- Euronics: Model No-EGR01(600MM)

12

-

-

... More
Providing, Supplying & Fixing in position storage type Hot Water electrical horizontal heaters with copper container, insulation, and stove enameled M.S. jacket, thermostatically controlled immersion heater, with pilot lamp, 15/20mm dia inlet with non return valve and 15/20mm dia outlet including making connections complete in all respects.GEYSER 15 LITER

59

-

-

... More
Providing, Supplying & Fixing in position storage type Hot Water electrical horizontal heaters with copper container, insulation, and stove enameled M.S. jacket, thermostatically controlled immersion heater, with pilot lamp, 15/20mm dia inlet with non return valve and 15/20mm dia outlet including making connections complete in all respects.GEYSER 25 LITER

449

-

-

... More
SOIL, WASTE AND VENT PIPES:Supplying installation testing and commissoning of Hubless centrifugally cast iron pipes as per ISI 15905 equivalent to NECO inclusive of all necessary special fitting like bends, tees, and caps, 'Y' bends for cleaning offsets, junctions, cowls, etc. lad under floor/fixed on walls and in pipe shafts etc. complete. The quoted rate should include lead and liftingcharges to all levels, necessary scaffolding and supports like hanger supports grip bolts and CV sheet 304 grade clamps etc. with prior approval of concerned Superitending Engineer100mm dia

11460

-

-

... More
150 mm dia

1010

-

-

... More
Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors :For 100mm inlet and 100mm outlet.

658

-

-

... More
Providing and fixing C Class G.I. pipes complete with G.I. fittings and clamps,including cutting and making good the walls etc32 mm nominal bore

2665

-

-

... More
40 mm nominal bore

670

-

-

... More
50 mm nominal bore

1165

-

-

... More
Painting of G.I. pipes with two coats of bitumastic paint wrapping polythene tape and applying the final coat of bitumastic paint. 32mm nominal bore

2665

-

-

... More
40 mm nominal bore

670

-

-

... More
50 mm nominal bore

1165

-

-

... More
Providing and Fixing Floor drain by fixing G.I. Reducing elbow of 100 x 50 mm in cement concrete 1:2:4 at all levels (excluding cost of grating) for connection to floor traps in sunken portions, complete as per required slope as per drawings and as per approval of the engineer-in-charge.

531

-

-

... More
Providing and fixing G.I. inlet fitting with one or more inlets fabricated from 100mm dia G.I. pipe and welded G.I. sockets and fixed to C.I. trap by lead joint as per standard detail.

657

-

-

... More
Providing and fixing cast brass Floor Clean out with suitable insert keys for opening, male threaded joint with G.I. socket lead caulked to soil pipe / waste pipe of C.I. and C.I.(LA) pipe as required complete as shown in the Sketch.100mm dia

104

-

-

... More
Providing and fixing 125mm dia round bronze C.P frame and grating with connecting stainless steel screws, complete as per requirements.

1188

-

-

... More
Providing and making Khurras 45x45 cm with average minimum thickness of 5cm Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 mm nominal size) over PVC sheet 1 m x 1 mx 400 microns, finished with 12mm Cement Plaster 1:3 (1 Cement : 3 Coarse Sand) and a coat of neat cement, rounding the edges and making & finishing the outlet complete.

202

-

-

... More
WATER SUPPLY SYSTEM FOR (INTERNAL)Providing and laying in walls/ceilings/floors 20 mm dia. medium grade having embossed as ISI Mark galvanised iron pipes of 1.63 Kilogram/metre necessary fitting remaking good the demolished portion with filling trenches and with primer of anti-corrosive oil paint, 2 coats complete. Including necessary scaffolding and removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc.complete

1905

-

-

... More
Providing and laying in walls/ceilings/floors 25 mm dia. medium grade having embossed as ISI Mark galvanised iron pipes of 2.49 Kilogram/metre necessary fitting remaking good the demolished portion with filling trenches and with primer of anti-corrosive oil paint , 2 coats complete. Including necessary scaffolding and removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc.complete

2955

-

-

... More
Providing and laying in walls/ceilings/floors 32 mm dia. medium grade having embossed as ISI Mark galvanised iron pipes of 3.20 Kilogram/metre necessary fitting remaking good the demolished portion with filling trenches and with primer of anti-corrosive oil paint , 2 coats complete. Including necessary scaffolding and removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc.complete

4485

-

-

... More
Providing and laying in walls/ ceilings/floors 40 mm dia. medium grade having embossed as ISI Mark galvanised iron pipes of 3.68 Kilogram/metre necessary fitting remaking good the demolished portion with filling trenches and with primer of anti-corrosive oil paint , 2 coats complete. Including necessary scaffolding and removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc.complete.

3900

-

-

... More
Providing and laying in walls/ceilings/floors 50 mm dia. medium grade having embossed as ISI Mark galvanised iron pipes of 5.17 Kilogram/metre necessary fitting remaking good the demolished portion with filling trenches and with primer of anti-corrosive oil paint , 2 coats complete. Including necessary scaffolding and removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc.complete

3485

-

-

... More
Providing and laying in walls/ceilings/floors 65 mm dia. medium grade having embossed as ISI Mark galvanised iron pipes of 5.17 Kilogram/metre necessary fitting remaking good the demolished portion with filling trenches and with primer of anti-corrosive oil paint , 2 coats complete. Including necessary scaffolding and removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc.complete

1360

-

-

... More
Providing and laying in walls/ceilings/floors 80 mm dia. medium grade having embossed as ISI Mark galvanised iron pipes of 8.57 Kilogram/metre necessary fitting remaking good the demolished portion with filling trenches and with primer of anti-corrosive oil paint , 2 coats complete. Including necessary scaffolding and removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc.complete

440

-

-

... More
Providing and laying in walls/ceilings/floors 100 mm dia. medium grade having embossed as ISI Mark galvanised iron pipes of 12.43 Kilogram/metre necessary fitting remaking good the demolished portion with filling trenches and with primer of anti-corrosive oil paint , 2 coats complete. Including necessary scaffolding and removing existing pipe lineif necessary and conveying and stacking the same in PWD chowky or as directed etc.complete

210

-

-

... More
Providing and fixing on walls/ ceiling/ floor 15 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.

7135

-

-

... More
Providing and fixing on walls/ceiling/floor 20 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directedtc. complete

7068

-

-

... More
Providing and fixing on walls/ ceiling/ floor 25 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directedetc. complete.

3165

-

-

... More
Providing and fixing on walls/ ceiling/ floor 32 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.

335

-

-

... More
Providing and fixing on walls/ ceiling/ floor 40 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.

75

-

-

... More
Providing and fixing Stainless Steel 316 L pipes confirming to EN 10312 complete with Press Type fittings with SC-Contur in accordance with DVGW regulation W534 such as sockets, bends, elbows, tees, reducers, unions, Flanges, clamps/structural steel supports, hangers etc. necessary adapters for GI to copper and copper to CP fittings, jointing, sundries, cutting holes in walls/floors/slabs & making good including wraping with polythene sheet tape etc. complete. 22 mm OD

960

-

-

... More
28 mm OD

700

-

-

... More
40 mm OD

410

-

-

... More
Providing and fixing forged brass lever operated ball valve of full flow with forged brass ball (Machined to mirror smooth finish with hard chrome plated) and spindle with setting and gland of superior quality having minimum working pressure of 16 kg/cm2 etc. complete in all respect.20 mm dia

647

-

-

... More
25 mm dia

767

-

-

... More
32 mm dia

299

-

-

... More
40 mm dia

286

-

-

... More
50 mm dia

141

-

-

... More
Providing, fixing, testing & commissioning of C.I. butterfly valve, wafer end type class PN 1.6 as per I.S:13095 or BS:5155, including necessary nuts, bolts, washers, gaskets etc., complete of following size: (flanges to be paid separately)65 mm dia

103

-

-

... More
80 mm dia

61

-

-

... More
100 mm dia

18

-

-

... More
Providing and fixing thermal insulation over hot water pipes in chase having Red Oxide Primer Coat with 6mm thick 'Kaiflex' /Careflex or approved equivalent thermal insulation tubing, a elastomeric flexible material having hermetic blister closed cell structure of expanded synthetic rubber having density of 60-90 Kg/m3 over pipes of following sizes including all required accessories complete as per Manufactuer's specifications and finishing it as per site requirement with Cement Plaster of 1:3 (1 Cement: 3 Coarse sand).15mm dia

1735

-

-

... More
20mm dia

2634

-

-

... More
25mm dia

995

-

-

... More
32mm dia

100

-

-

... More
Providing ,fixing , testing and commissioning of IP 67 ( Weather Proof /Aluminium casing with positoner to indicate the valve position with key type manual overdrive) Motorized Butterfly valve for filling of over head water tank complete with high and low level float type sensors to control the valve .The sensors shall be installed in over head tanks.The sensors will close the valve when water level is high in over head tank and open the valve when over head water tank level is low . The system should be complete in all respects with control panel indicating the position of valve i.e open /closed with accessories like wiring /conduting /flanges , nut bolts etc complete as per approved type and specifications as per instructions of the engineer - in - charge.25 mm Dia.

9

-

-

... More
32 mm Dia.

18

-

-

... More
40 mm Dia.

16

-

-

... More
50 mm Dia.

3

-

-

... More
EXTERNAL WATER SUPPLY SYSTEM (DOMESTIC, FLUSHING,GARDEN HYDRANT) Excavation for foundation in earth, soil of all types, sand, gravel and soft murum,including removing the excavated material up to a distance of 50 m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 0.00 to 1.50 m.) By Manual Means

8230

-

-

... More
Providing and fixing on walls/ ceiling/ floors, 25 mm dia. heavy grade having embossed as ISI Mark galvanised iron pipes weight of 3.01 Kilogram/meter with necessary fittings . remaking good the demolished portion and applying primer of anti-corrosive oil paint 2 coats Including necessary scaffolding and removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.

480

-

-

... More
Providing and fixing on walls/ ceiling/ floors, 32 mm dia. heavy grade having embossed as ISI Mark galvanised iron pipes weight of 3.89 Kilogram/meter with necessary fittings . remaking good the demolished portion and applying primer of anti-corrosive oil paint 2 coats Including necessary scaffolding and removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.

710

-

-

... More
Providing and fixing on walls/ ceiling/ floors, 40 mm dia. heavy grade having embossed as ISI Mark galvanised iron pipes weight of 4.49 Kilogram/meter with necessary fittings and remaking good the demolished portion and applying primer of anti-corrosive oil paint 2 coats Including necessary scaffolding and removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete

750

-

-

... More
Providing and fixing on walls/ ceiling/ floors, 50 mm dia heavy grade having embossed as ISI Mark galvanised iron pipes weight of 6.33 Kilogram/meter with necessary fittings.and remaking good the demolished portion and primer of anti corrossive oil paint 2 coats Including necessary scaffolding and removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.

290

-

-

... More
Providing and fixing on walls/ ceiling/ floors, 65 mm dia heavy grade having embossed as ISI Mark galvanised iron pipes weight of 6.33 Kilogram/meter with necessary fittings.and remaking good the demolished portion and primer of anti corrossive oil paint 2 coats Including necessary scaffolding and removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.

2200

-

-

... More
Providing and making flanged connection for the 80mm diameter cast iron pipe line including painting rubber insertion, nuts and bolts etc. complete.

3000

-

-

... More
Providing and making flanged connection for the 100mm diameter cast iron pipe line including painting rubber insertion, nuts and bolts etc. complete.

600

-

-

... More
Providing and making flanged connection for the 150mm diameter cast iron pipe line including painting rubber insertion, nuts and bolts etc. complete.

200

-

-

... More
Providing and fixing screw down for 25 mm dia. wheeled stop tap of brass including necessary sockets/union nut complete

215

-

-

... More
Providing and fixing screw down for 32 mm dia. wheeled stop tap of brassincluding necessary sockets/union nut complete

167

-

-

... More
Providing and fixing screw down for 40 mm dia. wheeled stop tap of brassincluding necessary sockets/union nut complete

131

-

-

... More
Providing and fixing screw down for 50 mm dia. wheeled stop tap of brass including necessary sockets/ union nut complete.

63

-

-

... More
Providing and fixing screw down for 65 mm dia. wheeled stop tap of brass including necessary sockets/union nut complete.

50

-

-

... More
Providing and fixing screw down for 80 mm. dia. wheeled stop tap of brass including necessary sockets/union nut complete.

30

-

-

... More
Providing and constructing Brick Masonry Inspection Chamber 60cm x 45cm x90cm including 1:4:8 cement concrete foundation 1:2:4 cement concrete channels half round G.S.W. pipes, Brick Masonry, plastering from inside and airtight C. I. cover of 75Kilogramwith lid and frame fixed in cement concrete.

72

-

-

... More
Providing and constructing Brick Masonry Inspection Chamber 60cm x 45cm x 90cm including 1:4:8 cement concrete foundation 1:2:4 cement concrete channelshalf round G.S.W. pipes, Brick Masonry, plastering from inside and airtight C. I. cover of 75Kilogramwith lid and frame fixed in cement concrete.

61

-

-

... More
Providing, laying and fixing P.V.C. pipe of 25mm dia. with fittings such as bends, tees, reducers, clamps, etc. including necessary excavation, trench filling etc. complete.Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.

650

-

-

... More
Providing, laying and fixing P.V.C. pipe of 25mm dia. with fittings such as bends, tees, reducers, clamps, etc. including necessary excavation, trench filling etc. complete.Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.

250

-

-

... More
Providing, laying and fixing P.V.C. pipe of 40mm dia. with fittings such as bends, tees, reducers, clamps, etc. including necessary excavation, trench filling etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.

300

-

-

... More
Providing, laying and fixing P.V.C. pipe of 50mm dia. with fittings such as bends,tees, reducers, clamps, etc. including necessary excavation, trench filling etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.

1200

-

-

... More
Providing, laying and fixing P.V.C. pipe of 75mm dia. with fittings such as bends, tees, reducers, clamps, etc. including necessary excavation, trench filling etc. complete.Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.

450

-

-

... More
Providing, laying and fixing P.V.C. pipe of 110 mm. dia. with fittings such as bends, tees, reducers, clamps, etc. including necessary excavation, trench filling etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.

3300

-

-

... More
EXTERNAL SEWERAGE & DRAINAGE SYSTEM Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring andstrutting etc. complete. (Lift upto 0.00 to 1.50 m.) By Manual Means

4720

-

-

... More
Excavation for foundation in earth, soils of all types, sand,gravel and soft murum,including removing the excavated material upto a distance of 50 metres beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift from 1.5m to 3.0m) By Mechanical Means

3800

-

-

... More
Providing , laying and fixing ,jointing Eco- drain 160 mm SN 4 Nu- Drain Upvc pipes or of equivalent make, manufacture as per EN 13476 with fittings such a bends, tees , coupler, etc, jointing with rubber lubricant including necessary excavation, trench refilling with selective excavated materialetc. complete.

630

-

-

... More
Providing , laying and fixing ,jointing Eco- drain 200 mm SN 4 Nu- Drain Upvc pipes or of equivalent make, manufacture as per EN 13476 with fittings such a bends, tees tees, coupler etc, jointing with rubber lubricant including necessary excavation, trench refilling with selective excavated materialetc. complete.

5500

-

-

... More
Providing , laying and fixing ,jointing Eco- drain 250 mm SN 4 Nu- Drain Upvc pipes or of equivalent make, manufacture as per EN 13476 with fittings such a bends, tees tees, coupler etc, jointing with rubber lubricant including necessary excavation, trench refilling with selective excavated materialetc. complete.

5100

-

-

... More
Providing, Laying and fixing, jointing Eco Drain 315 mm SN-04 Nu-Drain Upvc pipe or of equivalent make, manufacture as per EN 13476 with fittings such a bends, tees, coupler, etc. jointing with rubber lubricant, including necessary excavation, trench refilling with selective excavated material etc.

400

-

-

... More
Providing , Laying and fixing, jointing Eco Drain 400 mm SN-04 Nu-Drain Upvc pipe or of equivalent make, manufacture as per EN 13476 with fittings such a bends, tees, coupler, etc. jointing with rubber lubricant, including necessary excavation, trench refilling with selective excavated material etc.

1200

-

-

... More
Providing and laying cement concrete pipe of IS 458:2003 NP-2 class of 450mm diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2and curing etc. complete.

50

-

-

... More
Providing and laying cement concrete pipe of IS 458:2003 NP-2 class of 600mm diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete

800

-

-

... More
Providing and laying cement concrete pipe of IS 458:2003 NP-2 class of 800mm diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete.

650

-

-

... More
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round for sewerage pipes including bed concrete as per standard design :200 mm dia

5500

-

-

... More
250 mm dia

5830

-

-

... More
300 mm dia

400

-

-

... More
400 mm dia

1200

-

-

... More
450 mm dia

50

-

-

... More
600 mm dia

800

-

-

... More
800 mm dia

650

-

-

... More
Constructing brick masonry manhole in cement mortar 1:4 (1 cement : 4 coarse sand) with RCC Top slab with 1:2:4 mix (1 cement : 2 coarse sand: 4 graded stone aggregate 20mm nominal size) foundation concrete 1:4:8 mix ( 1 cement :4 coarse sand: 8 graded stone aggregate 40 nominal size), inside plastering 12mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand), finished with a floating coat of neat cement and making channels in cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement complete as per standard design . Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (Heavy duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) .(Excavation and 15mm thick cement plaster at the external surface is included in the item) : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5

196

-

-

... More
Extra depth of manholes Size 90x80cms

50

-

-

... More
Constructing brick masonry manhole in cement mortar 1:4 (1 cement : 4 coarse sand) with RCC Top slab with 1:2:4 mix (1 cement : 2 coarse sand: 4 graded stone aggregate 20mm nominal size) foundation concrete 1:4:8 mix ( 1 cement :4 coarse sand: 8 graded stone aggregate 40 nominal size), inside plastering 12mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand), finished with a floating coat of neat cement and making channels in cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement complete as per standard design . Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (heavy duty) 560 mm internal diameter, total weight of cover and frame to be not less than 116 kg (weight of cover 58 kg and weight of frame 58 kg) .(Excavation and 15mm thick cement plaster at the external surface is included in the item):With common burnt clay F.P.S. (non modular) bricks of class designation 7.5

49

-

-

... More
Extra depth of manholes Size 120x90cms

21

-

-

... More
Constructing Brick Masonry circular type manhole 0.91 m internal dia at bottom and 0.56m dia at top in cement mortar 1:4 (1 cement : 4 Coarse sand), inside cement plaster 12mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand) finished with a floating coat of neat cement, foundation concrete 1:3:6 mix ( 1 cement : 3 coarse sand : 6 graded stone aggregate 40mm nominal size) and making necessary channel in Cement Concrete 1:2:4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stone aggregate 20mm nominal size) finished with a floating coat of neat cement all complete as per standard design. External surface shall be finished with 15mm thick cement plaster 1:6 (1cement : 6 Coarse sand) as per side conditions.0.91 m deep with hinged DI cover and frame (heavy duty weight of cover & frame to be not less than 80 kg,) 560 mm internal diameter, fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including centering, shuttering all complete.(Excavation and 15mm thick cement plaster at the external surface is included in the item) :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5

125

-

-

... More
Extra depth for circular type Manhole 0.91 internal dia , depth beyond 0.91 m to 1.67 m

2

-

-

... More
Constructing brick masonry circular manhole 1.22 m internal dia at bottom and 0.56 m dia at top in cement mortar 1:4 (1 cement :4 coarse sand) inside cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement foundation concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement, all complete as per standard design :1.68 m deep with SFRC Cover and frame (heavy duty HD-20 grade designation) 560 mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182 kg. fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including centering, shuttering all complete. (Excavation, foot rests and 12 mm thick cement plaster at the external surface shall be paid for separately) :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5

100

-

-

... More
Extra depth for Circular type Manhole 1.22 m internal dia (at Bottom) With common burnt clay F.P.S. (non modular) bricks of class designation 7.5, Depth beyond 1.68 to 2.29 m

2

-

-

... More
Constructing brick masonry circular manhole 1.52 m internal dia at bottom and 0.56 m dia at top in cement mortar 1:4 (1 cement : 4 coarse sand) inside cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement, foundation concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement, all complete as per standard design :2.30 m deep with SFRC Cover and frame (heavy duty HD-20 grade designation) 560 mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182 kg. fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including centering, shuttering all complete.(Excavation, foot rests and 12 mm thick cement plaster at the external surface shall be paid for separately) :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5

70

-

-

... More
Extra depth for circular type manhole 1.52 m internal dia (at bottom) beyond 2.30 m :

2

-

-

... More
Constructing brick masonry catch basin with 75 class designation bricks in cement mortar 1:5 (1 cement: 5 coarse sand), 150mm thick foundation concrete 1:5:10 (1 cement: 5 coarse sand: 10 graded stone aggregate 40mm nominal size) inside and outside plaster in cement mortar 1:3 (1 cement: 3 coarse sand). inside finished with floating coat of neat cement, making haunches and channel in cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 20mm nominal size) neatly finished, complete as per standard design including excavation, refilling and disposal of surplus earth.Size 450X450X450mm inside with precast S.F.R.C. grating of approved design and sample fixed in Plain Cement Concrete 1:2:4 mix (1 cement: 2 coarse sand: 4 graded stone aggregate 20mm nominal size) including centering, shuttering all complete as per site conditions.

339

-

-

... More
Size 600X600X600mm inside with precast S.F.R.C. grating of approved design and sample fixed in Plain Cement Concrete 1:2:4 mix (1 cement: 2 coarse sand: 4 graded stone aggregate 20mm nominal size) including centering, shuttering all complete as per site conditions.

107

-

-

... More
Size 750x750x750mm inside with precast S.F.R.C. grating rectangular of approved design and sample fixed in Plain Cement Concrete 1:2:4 mix (1 cement: 2 coarse sand: 4 graded stone aggregate 20mm nominal size) including centering, shuttering all complete as per site conditions.

62

-

-

... More
Size 900x900x900mm inside with precast S.F.R.C. grating rectangular of approved design and sample fixed in Plain Cement Concrete 1:2:4 mix (1 cement: 2 coarse sand: 4 graded stone aggregate 20mm nominal size) including centering, shuttering all complete as per site conditions.

20

-

-

... More
Extra for depth of Catchbasin exceeding 45cm.

32

-

-

... More
Extra for depth of Catchbasin exceeding 60cm.

27

-

-

... More
Extra for depth of Catchbasin exceeding 75cm.

8

-

-

... More
Extra for depth of Catchbasin exceeding 90cm.

2

-

-

... More
Providing and fixing 15cm x 10cm salt glazed stoneware gully trap in cement concrete 1:4:8 outside the building including cast iron grating in the sink, connecting glazed stoneware pipe, brick masonry chamber with cast iron lid and cast iron grating for the gully trap.

178

-

-

... More
Providing & fixing orange colour safety foot rest of minimum 6mm thick plastic encapsulated as per I.S:10910 on 12 mm dia steel bar conforming to I.S:1786 having minimum cross section as 23mm x 25mm and over all minimum length 263mm and width as 165mm with minimum 165 mm space between protruded legs having 2mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacturer's permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15cm cement concrete block 1:3:6 (1 cement: 3 coarse sand: 6 graded stone aggregate 20mm nominal size) complete as per design.

1670

-

-

... More
Providing and installation Supervision,including all civil work of -Grease separator EasyClean ground Standard Model/ Article No.: NS 10_ 93010/120B , 740-1175 mm, class A/BThe separator for greasy wastewater is suitable for installation in the ground and comes without metallic components in the tank. The collecting tank made of permanently resistant polymer (PE) is equipped with an integrated sludge trap and has a rounded base for fast and clean disposal. Access for cleaning and maintenance work is possible via one or several service access covers.Manual disposal is carried out with the tank open.for 1200 to 1700 Meals/Day ( Breakfast + lunch+ Dinner)20 year polyethylene warranty.Installation situation: underground installationType of disposal: manual with suction hoseDisposal variant: StandardRefill inlet in accordance with DIN 1988: noNominal size (NS): 10Note on installation depth: Installation in the ground, frost-free depth 1200 mmMaterial: PEStandard: EN 1825: 2004, DIN 4040-100Max. length: 3,062 mmRequired access area, length: 2,910 mm ; width: 1,200 mmInlet nominal size (OD): 160 mm ; Outlet nominal size (OD): 160 mmDistance pipe bottom inlet to tank bottom: 1,100 mm ; Distance pipe bottom outlet to tank bottom: 1,030 mmInstallation depth: 740 - 1,175 mmGroundwater resistant from lower edge of base section: 1,320 mmClear width of entry (LW): 600 mmLoad class: B 125 (EN 124)Height: 95 mmTightness: odour-tight and surface water resistantSeparator contents: 1,600 lTotal volume: 2,600 l ; Contents of sludge trap: 1,000 l ; Storage quantity of grease: 400 l MAKE-KESSEL

3

-

-

... More
RAIN WATER HARVESTING WELLConstruction of rain water harvesting well of 4.5 metre dia and 4.5 metre effective depth with the operation of earth work in excavation and drilling with RC/DC/Calyx rig having 400/450mm dia bore size in all kind of starta except rock, back filling alround harvesting well with available excavated earth, with necessary compaction and shifting of surplus earth outside by mechanical means as directed by the Engineer-In-Charge, PCC 1:5:10 , 200mm thick foundation concrete, brick work in cement mortar 1:4 (1 cement : 4 coarse sand), PVC coated safety steel foot rest of 12mm dia MS bars grouted rigidly in cement concrete 1:2:4 @300mm c/c, 200mm thick RCC tank cover slab in cement concrete M20 i/c providing and placing necessary steel raft, bars and to keep the provision of removable slab of approx. 1mx1m size, filling 300mm, 300mm & 300mm thick of 40-65mm nominal size graded loose boulders, Gravel 5-10 mm size and sand layer respectively, CI vent pipe, (100mm dia), 250mm dia uPVC slotted pipes 6Kg./sq cm working pressure, filling around the slotted pipes and packing 3mm to 6mm sized graded and screened rounded Pea Gravel duly washed fabricating and placing grating at the mouth of pipes, placing 560mm dia SFRC manhole cover with frame etc. i/e all necessary materials and equipments required for all relevant operations as shown in the drawing.

40

-

-

... More
Providing and construction of brick masonry desilting chamber of size 200x100x50cm (effective depth) before rainy well with 75 class designation bricks in cement mortar 1:4 (1 cement : 4 coarse sand), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand; 8 graded stone aggregate 40mm nominal size), inside and outside plastering 12mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement inside and rough plaster on outside, including fixing of grating, neatly finished complete in all respects including 2nos of 560mm dia SFRC manhole with neccessary excavation in all kinds of soils, refilling and disposal of surplus earth, complete. (Shop drawing to be got approved).

40

-

-

... More
PUMPS & EQUIPMENTSName of Work: Designing, Preparation of Shop Drawings, Supplying, Erection, Testing, Commissioning, handing over, operation & maintenance up to succesfull commisioning , including purchase and usage of chemical / consumables for operation and maintenance of all Mechanical, Electrical, and other components , for Water Treatment Plant of capacity 340 KLD complete in all respects on a Turnkey Basis, as per Tender Document comprising Technical Conditions, Technical Specifications, Data, Drawings etc and any other documents attached with this Tender.Turnkey Cost for Designing, Supply, Installation, testing & Commissioning handing over, operation & maintenance upto successful commissioning, including purchase and usage of chemical / consumables for operation and maintenance of all Mechanical & Electrical Equipment, Piping, Valves & Accessories for the Complete Turnkey water Treatment Plant of 340 kld capacity (physical and secondary treatment ) as per approved Hydraulic Calculations, Design and Shop Drawings, as per details given in (but not restricted to) tender documents. ELECTROMECHANICAL EQUIPMENTSCollection Tank Submersible Pumps: The pump sets shall be supplied with required accessories, valves, fittings, cables etc. & as per specification. Min (2w+1s). Air Blower: Air Blowers of twin-lobe type (air cooled) for continuous service with construction in cast iron casing, supply complete with testing and commissioning etc.as specified and as required. Min (1w+1s). Air Diffusers: Membrane diffusers in High Grade Silicon material (Coarse & Fine Bubble as per requirements) with connections to air piping by threaded means, of tube/disc type as required as per process requirements complete with testing and commissioning etc.as specified and as required consisting of Disc Type for coarse bubbles with approx 5 m3 / hr Minimum Air capacity / throughput per Diffuser and Tube Type for fine bubbles with 9 m3 / hr Minimum Air capacity / throughput per Diffuser Sludge Return / Relift Pump at Tube settler: Centrifugal Sludge Return / Re-lift pumps for the transfer of sludge from tubesettler to anoxic complete in all respects and as per specifications. Dosing System: Providing and fixing chemical dozing system at coagulation and floculation tank with dosing tank and agitator of approved make with all standard accessories & structural arrangement including suitable foundation bolts & other accessories etc. complete as required and as specified. Agitator/Hydraulic Mixture for coagulation and floculation tank complete as per specifications Sludge Handling Mechanism (Centrifuge): Providing and fixing of sludge handling arrangement (Centrifuge basket type) complete with testing & commissioning as required and as specified. Sludge Trolley: Fabrication and supply of sludge trolley for transport of sludge complete as per requirements as specified. (Size 1.5m x2m x 1m) Bio media for MBBR tank and Tubesettler complete as per specificationsPIPING AND VALVES ACCESSORIESG.I. Pipe: Provding and fixing heavy duty G.I. pipe confiming to IS. 1239 upto 150 mm and IS 3589 for dia 200 mm and above complete as required & as per specifications. uPVC Threaded Water Pipes: Providing and fixing uPVC threaded water pipes (I.S:4985-2000) Class - 5 (Min. 10 Kg/cm2) complete as required & as per specifications. Butterfly Valves: Providing & fixing butterfly valve of rating PN 16 wafer type, in cast iron body with Ductile Iron disc, EPDM seal, SS single piece shaft, conforming to IS-13095, complete as required and as specified. Ball Valves: Providing and fixing forged brass ball valve having stainless steel / brass ball tested to 25 kg/cm2 complete as required and as specified. Puddle flanges: Providing & fixing GI hot dipped puddle flanges for the tank complete as per the specifications. Non-Return Valves: Providing & fixing non return valve Dual Plate type, conforming to API-594 or IS 3512, complete as required and as specified. Flow meter: Providing & fixing flow meter at the inlet and outlet, complete as required and as specified.CONSUMABLES FOR OPERATION AND MAINTENANCESupply & Consumption of Consumables, solutions, chemicals, etc. for operation and maintenance upto successful commissioning.ELECTRICAL SYSTEM Design, manufacture, supply, installation, testing and commissioning of the panel complete as required and as specified. Aluminium Conductor: Supply of sizes of 1.1KV grade XLPE insulated and PVC sheathed aluminium conductor armoured stranded power cables conforming to IS 7098 Part-1 as ammended upto date and as specified. Supplying and making of cable end termination with brass single compression gland and Al. lug for PVC insulated and sheathed armoured cables of 1.1 K.V. aluminum conductor as required. Laying and fixing of one number XLPE /PVC insulated and PVC sheathed power of 1.1 KV grade of following sizes on surface or existing cable tray complete as required. Earthing: Earthing with GI earth plate of 600mm x 600mm x 6mm thick, including accessories and providing masonary enclosure including MS cover plate having locking arrangement and watering pipe etc. with charcoal and salt complete as required & as specified. G.I. Strip: Providing and Fixing 25 mm x 5 mm G.I. Strip in 40 mm dia. G.I. pipe from earth electrode complete as required. G.I. Strip on Surface: Providing and Fixing 25 mm x 5 mm G.I. Strip on surface or in recess for earth connection as per specifications complete as required. G.I. Wire: Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. Cable Tray: Fabrication and installation of perforated MS cable tray including horizontal and vertical bends, reducers, tees, cross-members and other accessories as required duly suspended from the ceiling with MS Suspenders and including painting with black synthetic paint as required. Rubber Mat: Providing electric insulated rubber mat non-skid type with grooved top 90 cm wide & 12 mm thk as per IS : 5424 as required suitable for 1100 volts

1

-

-

... More
Filter Feed pumpSupply, Installation, Testing and Comissoning In-line vertical multistage centrifugal pump set (for clear water) SS-304 casing, SS-304 impeller, SS-316 shaft, CI base with coating, complete directly coupled with TEFC induction motor of class "F" insulation & efficiency class IE-5, 2900 RPM, suitable for operation on 415 volts ±10%, 3 phase, 50 Hz, A.C. supply, mechanical seal, pressure gauges with gunmetal isolation cocks, vibration elimination pads etc. mounted on a MS base frame bolted to cement concrete foundation etc. complete in all respects and as per technical speicification for following capacities: No. of Pumps : 3(2W + 1S)Capacity : (21 m3/hr) of Each Pump Head : 25 mNote:-1 set consists of 2 nos. of pumps (2 Working + 1Standby)

1

-

-

... More
Multi grade Filter Supply, Installation, Testing and Commissioning of vertical Multi grade Filter (comprising of minimum 750mm media in four graded layer and minimum Height on Straight 1500mm) fabricated from high performance M.S plate of minimum 10mm thick for shell &12mm thick for dished ends,(Quality of Steel as per IS:2062 Grade B),Tested to 5.0 Kg/m2 , internally treated with coal-tar epoxy, air scouring, collection system initial charge of media, M.S face piping with necessary flanges, gaskets, isolating valves, accessories, nuts & bolts, external painting with 2 coats of red oxide primer and enamel paint etc. with suitable foundation bolts & other accessories, mounting frame, complete as required & as per technical specifications of the following capacities: Discharge : 42 m3/Hour Each Filtration Rate : 17500 lit./m2/h Dia. : 1.8 m I.D.

1

-

-

... More
Activated carbon Filter Supply, Installation, Testing and Commissioning of vertical activated carbon Filter (comprising of minimum 750mm media in four graded layer including carbon and anthra cite and minimum Height on Straight 1500mm) fabricated from high performance M.S plate of minimum 10mm thick for shell & 12mm thick for dished ends,(Quality of Steel as per IS:2062 Grade B),Tested to 5.0 Kg/m2 , internally treated with coal-tar epoxy, air scouring, collection system initial charge of media, M.S face piping with necessary flanges, gaskets, isolating valves, accessories, nuts & bolts, external painting with 2 coats of red oxide primer and enamel paint etc. with suitable foundation bolts & other accessories, mounting frame, complete as required & as per technical specifications of the following capacities: Discharge : 42 m3/Hour Each Filtration Rate : 17500 lit./m2/h Dia. : 1.8 m I.D.

1

-

-

... More
Chlorinator for academic zoneSupply, Installation, Testing and Commissioning chemical dozing system consisting of 2 nos. electronic dosing pumps (1W+1S) with all accessories, suitable to doze chemical solution upto 1 ppm doze of Sodium Hypo-chloride solution to a filtered water flow of 42000 LPH against a pressure of 1.5 kg/cm2 complete with FRP moulded solution holding tank of min. 200 litre with all standard accessories & structural arrangement including suitable foundation bolts & other accessories etc. complete as per technical specifications as required.Note:1 set consists of 2 nos. of pumps(1W+1S)

1

-

-

... More
(Hydropneumatic Pumping System With Variable Frequency Drive)Supply, Installation, Testing and Commissioning of compact packaged type skid mounted, self contained variable frequency drive hydropneumatic system complete as per the technical specification complete as required:-(i) In- line vertical multistage centrifugal water pump set (for clear water) with SS-304 casing, SS-304 impeller with SS-316 shaft ,CI base with coating complete directly coupled with TEFC induction motor of class "F" insulation & efficiency class IE-5, 2900rpm, suitable for opertion on 415 Volts ±10%, 3 phase, 50 Hz A.C. supply. The entire system shall be mounted on a common base frame i/c common suction and common delivery of G.I heavy class pipe headers with flanges, interconnecting piping with all required Conrol Valves, Non-return valves, pressure guage with isolation cock etc. complete as required.(ii) Pressure vessel of non corrosive FRP composite construction lined with NSF and/or FDA listed material, like high density polyethylene with fully replaceable polyurethane. Air cell burst pressure of minimum of 3 times the vessel operating pressure and prototype cycle tested for 80,000 cycles with charging connections to dischage pipe line with necessary flanges, gaskets, isolating valve, nuts/ bolts etc. with suitable foundation boits etc complete as required.(iii) Microprocessor based multi pump contoller/panel with graphical display and variable frequency drive (VFD) mounted inside a panel complete with pressure sensor transmitter. The graphical display capable to show number of pumps running & also communicate with other controllers following with open protocol through RS485 port. System should be capable to compensate for frictional losses at lower flows. All alarms should be displayed in the controller. The panel should also have provision for manual / automatic alternate (cyclic) operation of pumps, ON/OFF switch complete as required.(v) Necessary foundationing bolts, vibration elimination pads etc complete as required.Domestic Water Supply Pumps for Academic zone OHT fillingDuty of each pump suitable for:-No. of Pumps : 2 nos. (1 W + 1 S)Capacity : 9 m3/hr of Each PumpHead : 70 MetersAir Vessel : 100 Ltr tankNote:-1 set consists of 2 nos. of pumps (1 Working + 1Standby)

1

-

-

... More
Domestic Water Supply Pumps for residential and hostel zone OHT fillingDuty of each pump suitable for:-No. of Pumps : 2 nos. (1 W + 1 S)Capacity : 12 m3/hr of Each PumpHead : 70 MetersAir Vessel : 100 Ltr tankNote:-1 set consists of 2 nos. of pumps (1 Working + 1Standby)

1

-

-

... More
Water Supply Pumps for transferring water to resintial zone under ground tanks, and the irrigation tank at STP of both zone Duty of each pump suitable for:-No. of Pumps : 2 nos. (1 W + 1 S)Capacity : 12 m3/hr of Each PumpHead : 50 MetersAir Vessel : 100 Ltr tankNote:-1 set consists of 2 nos. of pumps (1 Working + 1Standby)

1

-

-

... More
Drainage Sump Pump for Plant room & Basement drainageSupply, installation, testing and commissioning compact monoblock dry motor sump pumps of suitable rating, with non-clog free flow open impeller, solid handling capacity at least 28mm suitable for operation on 415 volts +10% , 3 Phase, 50Hz, A.C supply, speed 2900 RPM including oil chamber, guide wire for lifting & lowering of pump, G.I. galvanized lifting chain, complete.The above pump sets must be supplied complete with following accessories. GI Piping of 80mm dia for individual pump delivery line and 100mm dia for common delivery line, to be terminated outside the sump. 80mm dia Butterfly valve.--3 Nos 80 mm dia reflux valve.-- 3 Nos Electrical switch panel with DOL starter having all necessary accessories & safety devices of standard specifications. Automatic built-up water level controller with necessary length of cable upto control panel. No. of Pumps/set : 3nos. (2 W + 1 S)Discharge - 250 LPM Each Head - 15 Meters

1

-

-

... More
Supply, installation, testing and commissioning reinforced neoprene rubber vibration eliminators/expansion joints (to provide relief from stresses at pipe flanges) suitable for upto 20 kg/cm2 pressure,complete as per specifications as required.80mm dia

4

-

-

... More
100mm dia

4

-

-

... More
150 mm dia

4

-

-

... More
Supply, installation, testing and commissioning of 750 mm long hot dipped G.I. Puddle flanges for water tanks as per I.S. 1239 (Class C) with 6mm thick M.S. Plate of suitable size and welded alround the pipe fixed in walls, beams and top slab of R.C.C tanks, complete with all details in all respects and as per drawing and specifications. 50 mm dia

10

-

-

... More
65 mm dia

10

-

-

... More
80mm dia

5

-

-

... More
100mm dia

20

-

-

... More
150mm dia

10

-

-

... More
200 mm dia

5

-

-

... More
250mm dia

5

-

-

... More
Supply, installation, testing and commissioning of double flanged Water Flow Meter complete with digital display provision & including Pulse generator and Remote Totalizer complete in all respect as per the technical specifications & and should be compatible with BMS.50 mm dia

4

-

-

... More
65mm dia

4

-

-

... More
80 mm dia

4

-

-

... More
100 mm dia

4

-

-

... More
Supply, installation, testing and commissioning of insect-proof coupling,to vent pipes of water tank with threaded or flanged joints, including G.I. flanges, nuts, bolts, 3mm thick rubber insertions complete as per technical specifications.80 mm dia

6

-

-

... More
100 mm dia

6

-

-

... More
Providing & fixing M.S. structural work fabricated from standard section e.g. M.S Flat Strips, Round Bars, angles, channels, plates etc. including cutting to size, drilling, welding, fixing either by welding to insert plates in RCC structural members including cutting and making good the walls, ceilings and floors or by dash fasteners. (As per the Instructions of the Engineer-in-Charge)

1500

-

-

... More
Providing and Fixiing extra heavy duty, water tight double sealed Ductile iron Circular Manhole cover and frames specially casted for placing over the UG Water tanks with lifting and locking arrangements as per approved sample, complete in all respect including fixing in PCC as per site Requirement .

1000

-

-

... More
Electrical panel Design, manufacture, supply, installation, testing and commissioning of the Plumbing panel, front operated, cubicle construction, Floor mounted type, fabricated out of 16 swg thick CRCA Sheet, Compartmentalized with hinged lockable doors, dust and vermin proof, Powder coated of approved shade, Cable alley, inter-connections, having Switch gear and accessories mounting, internal wiring, earth terminals, Top/ Bottom cable entry, numberings etc. suitable for operation of 415 volts, 3 phase, 50 Hz, AC Supply with enclosure protection class IP 54 complete as required and as specified with the following:INCOMER - Each Incomer shall consit of :100 Amps,Four pole, 11 KA MCCB with rotary handle on door. Voltmeter (0-500 Volts) with selector Switch & protected by MCB's.Ammeter (0-300 Amps) with selector Switch &CT's etc.Set of (R,Y,B) LED phase and ON & OFF indication Lamps.BUSBAR1 Set 11KV, 150 Amps Three Phase busbars of aluminium with Rear cable termination.OUT GOING FOR :-Filter feed pumps set for Ph-1 ( 3 Nos. Pump - 1 set)Pump feeder shall consit of :Suitable rating MPCB with DOL Starter for outgoing feeder of 3 HP. Each Compartment shall contain Auto/Manual Selector Switch and Indicating Lamp for ON/TRIP Status of Motor---2 NosAmmeter (0-100 Amps) with selector Switch & CT's etc.Set of ON / OFF LED indication Lamps protected by MCB.Domestic Water Supply hydropneumatic pumps set (1 w+1s) pumps40 Amps. TP with nuetral link MCCB ( Motor Duty) 1.1 KA with rotary handle on door suitable for 7.5 HP and for Connection to Built up Hydro Panel.---1No.Chlorine dosing system Each pump set feeder shall consit of : 6 Amps. DP, 10 KA "C" curve MCB with DOL Starter suitable for single phase 240 V, 50 Hz AC supply. Inter locking with filter feed pump treated water pump suitable for 0.5 HP ---2Nos.Set of ON / OFF indication Lamps protected by MCB. For Drainage Sump Pumps Plant Room area - 3 Nos.(2W +1S) Pump feeder shall consit of : 32 Amps. TP MCCB 25 KA with rotary handle on door suitable for Connection to Built up Panel.--1NoNOTE:-1. All MCCB shall have 100% Ics =Icu 2.Panel shall be provided with NO-NC Potential free contact for BMS compliance.

1

-

-

... More
Pump motor controller cum water level indicating panel Supply, installation, testing and commissioning of Centralised PLC control panel front operated, cubicle construction, wall mounted type, fabricated out of 1.6 mm thick CRCA Sheet, with hinged lockable doors, dust and vermin proof, powder coated of approved shade, inter-connections, having, internal wiring, earth terminals, Top / Bottom control cable entry, numberings etc.comprises of touch-screen display board (Min.Diag. size 8") along with all accessories for complete Programmable logical controls & indications,having necessary interlocks, Inputs/Outputs, required number of repeater amplifiers, all audio-visual alarms as per the requirements listed below i/c emergency stop push button on the panel etc. The panel shall have BMS compatible Modbus protocol complete as required and as specified.Water level indicators and controllers : The hydrostatic pressure sensor (Water level indicator) is working on hydrostatic pressure measurement principle made of Stainless Steel for installation in storage tanks, and capable of providnig 4 to 20 mA analog signal compatible with PLC signal inputs and all control outputs to MCC panel (Plumbing/Water supply),complete as per working requirements for equipment detailed below. Fire Static Underground tanks- 1 No.Real-Time water level indication monitoring Low Level audio-visual alarm at less than 30% total capacity. Raw Water Underground tanks- 1 No.Real-Time water level indication monitoringLow Level audio-visual alarm at less than 30% total capacity.High Level audio-visual alarm at more than 100% total capacity.Auto cut-out of raw water pumps at 95 % capacity of domestic tankAuto cut-in of raw water pumps at 25 % capacity of domestic tankAuto cut-out of raw water pumps at 10% capacity of raw water tank Domestic Water Underground tanks- 1 No.Real-Time water level indication monitoringLow Level audio-visual alarm at less than 30% total capacity.High Level audio-visual alarm at more than 100% total capacity.

1

-

-

... More
Providing of ISI Marked multicore PVC insulated and PVC sheathed copper conductor armoured control cable of 1.1 KV grade confirming to IS 1554 (Part-1) as ammended upto date and as specified of following sizes. including necessary support clamps at ceiling level and connection legs complete in all respects as per directions of the engineer-in-charge. 2 core 1.5 Sq.mm

500

-

-

... More
Providing of following sizes of 1.1KV grade XLPE insulated and PVC sheathed copper conductor armoured stranded power cables conforming to IS 1554 (Part-1) & (7098 Part-1) as ammended upto date and as specified, including necessary support clamps at ceiling level, connection lugs and double compression glands, complete in all respects as per directions of the engineer-in-charge.3 core 2.5 Sq.mm

100

-

-

... More
3 core 4 Sq.mm

150

-

-

... More
3 core 6 Sq.mm

100

-

-

... More
3 core 10 Sq.mm

100

-

-

... More
3 core 16 Sq.mm

150

-

-

... More
Providing & Fixing of electric insulated rubber mat non-skid type with grooved top size 1m x 2m and 12 mm thick as per IS : 5424 as required suitable for 1100 volts complete as per directions of the engineer-in-charge.

2

-

-

... More
Providing, fixing and commissioning suitable complete composite hydropneumatic system consisting of horizontal /vertical multistage centrifugal pump having stainless steel (SS 304) impellers, shaft and housing, with single mechanical seal and pressurised tank of 50 liters capacity, complete with all standard accessories including pressure switch, pressure gauges, non-return & isolating valves on suction and delivery side with nuts, bolts & washer including mild steel flanges, where ever required with 3 mm thick rubber insertion, with necessary protection and operational devices i.e alternate pumping operation and shut-off during dry running conditions etc. with suitable electrical motor to be operated on 210/220 or 400/440 volt 50 cycle AC supply, suitable for following duty and with total no. of pumps - 2 nos.(1 working+1standby) complete with Control Unit Panel, manifolds & chassis, as per the approval of Project-in-charge complete with base frame, nuts, bolts and washer, necessary RCC foundation as per requirement.No. of Pumps/Set : 2 ( 1 Working + 1 Stand by ) , Capacity : app. 150 lpm per pumpHead : app. 25 m

15

-

-

... More
Providing, laying, testing & commissioning of 'C' class heavy duty G.I. pipe conforming to IS 1239 including welding, fittings like elbows, tees, flanges, tapers, nuts,bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :50 mm dia

50

-

-

... More
65 mm dia

50

-

-

... More
80mm dia

75

-

-

... More
100mm dia

100

-

-

... More
150mm dia

100

-

-

... More
Providing, installation, testing and commissioning of Cast Iron Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange.80 mm dia

4

-

-

... More
100mm dia

6

-

-

... More
150mm dia

6

-

-

... More
Supplying, fixing, testing and commissioning of butterfly valve of PN 16 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required :65mm dia

10

-

-

... More
80mm dia

10

-

-

... More
100mm dia

20

-

-

... More
150mm dia

10

-

-

... More
Providing and fixing 50 mm dia gun metal gate valve with C.I. wheel of approved quality (screwed end) :

10

-

-

... More
Providing, installation, testing and commissioning of non-return valve of following sizes confirming to API 594 or as per IS 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :65mm dia

6

-

-

... More
80mm dia

6

-

-

... More
100mm dia

6

-

-

... More
Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910 on 12mm dia steel bar conforming to IS : 1786 having minimum cross section as 23 mmx25mm and over all minimum length 263 mm and width as 165mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture's permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design.

100

-

-

... More
Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc. as required.100 mm width X 50 mm depth X 1.6 mm thickness

100

-

-

... More
150 mm width X 50 mm depth X 1.6 mm thickness

100

-

-

... More
200 mm width X 50 mm depth X 1.6 mm thickness

150

-

-

... More
300 mm width X 50 mm depth X 1.6 mm thickness

50

-

-

... More
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. Upto 35 sq. mm (clamped with 1mm thick saddle)

1100

-

-

... More
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.

2

-

-

... More
Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.

150

-

-

... More
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.

200

-

-

... More
R.O. DRINKING WATER GENERATION SYSTEM CENTRALIZED DRINKING WATER SYSTEM FOR 500 LPH AS PER FOLLOWING SPECIFICATIONSupply, installation, testing and commissioning of R.O. Plant capacity of 500 LPH (Complete system to be compact type, skid-mounted / cabinet enclosed, as per detailed shop drawings to be approved) consisting of (but not limited to) the following main components:- Output water hardness: 100 ppm, Output water TDS: less than 75ppm, Output water Suspended solid: NIL, Output water PH: 6-7 & Output water turbidity: NILRaw Water pumps of horizontal, centrifugal type suitable for a flow rate of 1000 LPH at 25m head. The Pump construction shall be of SS-316 & impeller shall be also SS-316. The motor shall be TEFC suitable for a supply of 415V/3-phase/50Hz supply. The pump shall be supplied complete with base channel coupling foundations, bolts, pressure gauge at inlet and outlet of each pump. -- 2 Nos. Special Antiscalant Dosing System consisting of one HDPE tank of 100 litre capacity with a positive displacement diaphragm dosing pump having variable flowrate of 0-6 LPH. The motor shall be suitable for operation at 240V/single phase/50Hz supply. the pump shall be supplied complete with necessary polypropylene piping, valves, strainers & injection fittings, -- 1 Set.Activated Carbon Filter suitable for a flow rate of 1000 LPH. The material of construction shall be composite FRP. The unit shall be supplied complete with inlet and outlet branches removal caps of replacement of elements inlet and outlet pressure indicators. -- 1 SetMicron cartridge filter suitable for a flowrate of 1000 LPH to achieve particle filtration of less than 5 microns. The unit shall be supplied complete with inlet and outlet branches removal cap for replacement of element, inlet and outlet pressure indicators. (One for the pressure treatment & other for CIP system) -- 2 setsR.O High Pressure feed pumps of vertical, multistage centrifugal type suitable for a flowrate of 1000 LPH at pressure as per design criteria. The pump construction shall be of SS-316 & impeller shall be also SS-316. The motor shall be of TEFC suitable for a supply of 415V/3 phase/50 Hz supply. the pump shall be supplied complete with base channel coupling foundation, bolt, pressure gauge at inlet and outlet of each pump.- 2 Nos.R.O. modules made out of Spiral Wound Thin Film composite suitable to withstand pressure of 20kg/sq.cm. Suitable BSPT/NPT connections shall be used for connecting feed & reject ends. the modules shall be supplied complete with all necessary instrumentation, valves for sampling, drain, reject & permeate, epoxy-coated structural steel bases and supports, as per following system capacity requirements: (i) Total net treated water output of system = 500 LPH (ii) System recovery = 60 - 66 % ( min)(iii) Filtration area per membrane = 85 sq.ft. (iv) Number of membranes = Min. 1 nos. (The total number of membranes required may be increased as per requirements, supported by calculations from the vendor. Clean in place pump of horizontal end suction suitable for a flow rate of 1000LPH at 25 m head. The pump construction shall be of stainless steel SS-316. The motor shall be TEFC suitable for a supply of 415V/3 phase/50Hz supply. The pump shall be supplied complete with base channel, coupling, foundation bolts, pressure gauge at inlet & outlet of each pump. -- 1 SetCentralised PLC control panel along with touch-screen digitial display board along with all digital sensors for TDS & Flow, made out of CRCA sheet min. 2mm thick having main contactors for all pumps (listed above) including SPP, 3 phase thermal overload relay. The control panel for monitoring and control of P.O. system shall include all required signal lamps, HRC fuses, Annunciation box with Hooter. All control and power cabling along with double earthing between the panel shall be included in the scope of supply of the contractor. An emergency stop push button shall be provided in the panel. The MCC panel shall have the following interlocks:-High Pressure Pump unit trip in case of Low suction pressure.High Pressure Pump unit trip in case of High discharge pressure.Special anti-scalant dosing pump trips in case high pressure pump trips and vice versa.High Pressure pump trip in case of high conductivity in permeate.SHC dosing pump trips incase high pressure pump trips and vice versa.In all above cases Annuciator box indicates nature of malfunctioning.The System should display the TDS of Raw Water & R.O. Water, Flow Rate of Inlet, Outlet & Reject Water simultaneously. Instrumentation mounted in R.O. system/panel as follows:-Digital Flow meters to measure and control the flow of feed/product/reject stream. -- 3 Nos.Pressure Gauges made out of SS316 (glycerine filled) of pricol/equivalent make. -- 5 Nos.Digital Conductivity probes for conductivity display -- 2 Nos.Pressure Switches to control pressure and given High/Low pressure trip. -- 4 Nos.Level switches to control water level in the output storage tank. -- 2 Nos. ORP with dump valve. -- 1 SetFirst fill of all chemicals and lubricants to commission and operate the plants. --1 LotAll interconnecting piping work with valves:-Low Pressure Side till R.O. feed water pump. Piping shall be of extra strong PVC and all valves shall be of extra strong PVC and all valves shall be PVC ball valves. -- 1 LotHigh Pressure side piping from the R.O. high pressure pumps to the reject stream control valves shall be of SS - 304 using all SS fittings ball valves of suitable pressure rating shall be used till 25 mm size, above 25 mm, flanged globe/ wafer butterfly valves in SS construction shall be used. Rejects pressure control valves shall be globe valve and feed flow control valve shall be of SS-304. -- LotComplete Stainless Steel treated water storage tank (ribbede Wall ) of capacity 1000 Litres including all inlet/outlet connections, accessories, valves, double seal manhole covers, insulation etc. The Stainless steel tank must be ozone resistant and to be used as ozone contact tank. Fabrication to be done as per approved shop drawing.

15

-

-

... More
Water cooler for drinking water systemSupply installation, testing and commissioning of self contained Drinking water cooler confirming to IS : 1475 with ammendment no. 1 to 7, suitable for operation on 230 volts ± 10% ,50 Hz,single phase A.C. supply. The tank and body casing of the water cooler shall be made out of stainless steel . The water cooler will be of following capacities with two numbers faucets / stop cocks for hot and cold water outlet: Nominal Storage Capacity -80 Ltrs. Nominal cooling Capacity -50 Ltrs/ hrs.

50

-

-

... More
SEWERAGE TREATMENT PLANT 35 KLD FOR ACADEMIC ZONEName of Work: Designing, Preparation of Shop Drawings, Supplying, Erection, Testing, Commissioning, handing over, operation & maintenance up to succesfull commisioning , including purchase and usage of chemical / consumables for operation and maintenance of all Mechanical, Electrical, and other components including getting approval of successful test results from approved Government pollution & environmental authorities, for Sewage Treatment Plant of 35 kld capacity based on MBBR technology with ultrafiltration system complete in all respects on a Turnkey Basis, as per Tender Document comprising Technical Conditions, Technical Specifications, Data, Drawings etc and any other documents attached with this Tender. (Any item not specifically mentioned in these sections but required for the successful completion including handing over, extended DLP, Operation & Maintenance of the STP shall be included in the Quote by the Contractor.)Turnkey Cost for Designing, Supply, Installation, testing & Commissioning handing over, operation & maintenance upto successful commissioning, including purchase and usage of chemical / consumables for operation and maintenance of all Mechanical & Electrical Equipment, Piping, Valves & Accessories for the Complete Turnkey Sewage Treatment Plant as per approved Hydraulic Calculations, Design and Shop Drawings, as per details given in (but not restricted to) tender documents. ELECTROMECHANICAL EQUIPMENTSEqualization Tank Sewage Pumps: The pump sets shall be supplied with required accessories, valves, fittings, cables etc. & as per specification. Air Blower: Air Blowers of twin-lobe type (air cooled) for continuous service with construction in cast iron casing, supply complete with testing and commissioning etc.as specified and as required.Air Diffusers: Membrane diffusers in High Grade Silicon material (Coarse & Fine Bubble as per requirements) with connections to air piping by threaded means, of tube/disc type as required as per process requirements complete with testing and commissioning etc.as specified and as required consisting of Disc Type for coarse bubbles with approx 5 m3 / hr Minimum Air capacity / throughput per Diffuser and Tube Type for fine bubbles with 9 m3 / hr Minimum Air capacity / throughput per DiffuserSludge Return / Relift Pump at Tube settler: Centrifugal Sludge Return / Re-lift pumps for the transfer of sludge from tubesettler to anoxic complete in all respects and as per specifications.Sludge recirculation pump at MBBR tank: Submersible type sludge recycle pump for nitrate recycle from MBBR to Anoxic complete in all respects and as per specifications.Sludge Loading/Disposal Pump: Screw Type Sludge loading / Disposal pump, complete in all respects and as per specifications. Filter Feed Pumps: In-line vertical multistage centrifugal clear water pump set of approved make, complete in all respects and as per specifications.Hydropneumatic Pumping System With Variable Frequency Drive: Supply, Installation, Testing and Commissioning of compact packaged type skid mounted, self contained variable frequency drive hydropneumatic system complete as required & as per specifications.(i) Flushing Water Supply Pumps(ii) Horticulture water supply pumpsDual media Filter: Providing and fixing vertical Dual Media Pressure Filter with suitable foundation boits & other accessories, mounting frame, complete with testing and commissioning etc.as required & as specified.Activated Carbon Filter: Providing and Fixing of Activated carbon filter as per Manufacturer's standard and testing & commissioning complete.Dosing System: Providing and fixing chemical dozing system at Anoxic tank and for centrifuge of approved make with all standard accessories & structural arrangement including suitable foundation bolts & other accessories etc. complete as required and as specified.Ultrafiltration system skid mounted type with feed pump, Cartidge filter, backwash pump, CIP system, Dosing system, UF membrane, PLC panel, Air compressor, intruments and piping, valves etcOzonation system at the clarified water tank complete as per specificationsAgitator/Hydraulic Mixture for Anoxic tank complete as per specificationsDrainage Sump Pumps: Providing and fixing compact dry motor submersible pumps of suitable rating. The pump sets shall be supplied with required accessories & as per specifications with all accessories and control system.Sludge Handling Mechanism (Centrifuge): Providing and fixing of sludge handling arrangement (Centrifuge bowl type) complete with testing & commissioning as required and as specified.UV for Supply to Flushing, Garden water outlet Line: Providing and installation of Online UV system complete with testing & commissioning as required and as specified.Sludge Trolley: Fabrication and supply of sludge trolley for transport of sludge complete as per requirements as specified.Bio media for MBBR tank and Tubesettler complete as per specificationsBar Screens: Providing and fixing manually cleaned Bar Screens, to remove coarse and fine material in the water made up of FRP complete as required and as specified, consisting of coarse screen & fine screen.PIPING AND VALVES ACCESSORIESG.I. Pipe: Provding and fixing heavy duty G.I. pipe confiming to IS. 1239 upto 150 mm and IS 3589 for dia 200 mm and above complete as required & as per specifications.uPVC Threaded Water Pipes: Providing and fixing uPVC threaded water pipes (I.S:4985-2000) Class - 5 (Min. 10 Kg/cm2) complete as required & as per specifications.Butterfly Valves: Providing & fixing butterfly valve of rating PN 16 wafer type, in cast iron body with Ductile Iron disc, EPDM seal, SS single piece shaft, conforming to IS-13095, complete as required and as specified.Ball Valves: Providing and fixing forged brass ball valve having stainless steel / brass ball tested to 25 kg/cm2 complete as required and as specified.Puddle flanges: Providing & fixing GI hot dipped puddle flanges for the tank complete as per the specificationsNon-Return Valves: Providing & fixing non return valve Dual Plate type, conforming to API-594 or IS 3512, complete as required and as specified.CONSUMABLES FOR OPERATION AND MAINTENANCESupply & Consumption of Consumables, solutions, chemicals, etc. for STP operation and maintenance upto successful commissioning of STPELECTRICAL SYSTEM STP Panel: Design, manufacture, supply, installation, testing and commissioning of the STP panel complete as required and as specified.Aluminium Conductor: Supply of sizes of 1.1KV grade XLPE insulated and PVC sheathed aluminium conductor armoured stranded power cables conforming to IS 7098 Part-1 as ammended upto date and as specified.Supplying and making of cable end termination with brass single compression gland and Al. lug for PVC insulated and sheathed armoured cables of 1.1 K.V. aluminum conductor as required.Laying and fixing of one number XLPE /PVC insulated and PVC sheathed power of 1.1 KV grade of following sizes on surface or existing cable tray complete as required.Earthing: Earthing with GI earth plate of 600mm x 600mm x 6mm thick, including accessories and providing masonary enclosure including MS cover plate having locking arrangement and watering pipe etc. with charcoal and salt complete as required & as specified. G.I. Strip: Providing and Fixing 25 mm x 5 mm G.I. Strip in 40 mm dia. G.I. pipe from earth electrode complete as required. G.I. Strip on Surface: Providing and Fixing 25 mm x 5 mm G.I. Strip on surface or in recess for earth connection as per specifications complete as required. G.I. Wire: Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. Cable Tray: Fabrication and installation of perforated MS cable tray including horizontal and vertical bends, reducers, tees, cross-members and other accessories as required duly suspended from the ceiling with MS Suspenders and including painting with black synthetic paint as required.Rubber Mat: Providing electric insulated rubber mat non-skid type with grooved top 90 cm wide & 12 mm thk as per IS : 5424 as required suitable for 1100 volts.INSTRUMENTATION EQUIPMENTS & INSTRUMENTATION DETAILFlow Meter: Electro Magnetic Type (5nos) compatible with BMS Online monitoring system for PH, BOD, COD and TSS.Energy Meter: -1No. Pressure Gauges:-1Lot Level Sensor-1Lot Level Gauges:-1Lot TDS Meter (Digital, Microprocessor based): Hand-held -1 No. Ultrasonic Level Transmitter: Range 10 m, mounting: Integral (Tank Top)

1

-

-

... More
SEWERAGE TREATMENT PLANT 100 KLD FOR RESIDENTIAL AND HOSTEL ZONEName of Work: Designing, Preparation of Shop Drawings, Supplying, Erection, Testing, Commissioning, handing over, operation & maintenance up to succesfull commisioning , including purchase and usage of chemical / consumables for operation and maintenance of all Mechanical, Electrical, and other components including getting approval of successful test results from approved Government pollution & environmental authorities, for Sewage Treatment Plant of 100 kld capacity based on MBBR technology with ultrafiltration system complete in all respects on a Turnkey Basis, as per Tender Document comprising Technical Conditions, Technical Specifications, Data, Drawings etc and any other documents attached with this Tender. (Any item not specifically mentioned in these sections but required for the successful completion including handing over, extended DLP, Operation & Maintenance of the STP shall be included in the Quote by the Contractor.) Turnkey Cost for Designing, Supply, Installation, testing & Commissioning handing over, operation & maintenance upto successful commissioning, including purchase and usage of chemical / consumables for operation and maintenance of all Mechanical & Electrical Equipment, Piping, Valves & Accessories for the Complete Turnkey Sewage Treatment Plant as per approved Hydraulic Calculations, Design and Shop Drawings, as per details given in (but not restricted to) tender documents. ELECTROMECHANICAL EQUIPMENTSEqualization Tank Sewage Pumps: The pump sets shall be supplied with required accessories, valves, fittings, cables etc. & as per specification. Air Blower: Air Blowers of twin-lobe type (air cooled) for continuous service with construction in cast iron casing, supply complete with testing and commissioning etc.as specified and as required.Air Diffusers: Membrane diffusers in High Grade Silicon material (Coarse & Fine Bubble as per requirements) with connections to air piping by threaded means, of tube/disc type as required as per process requirements complete with testing and commissioning etc.as specified and as required consisting of Disc Type for coarse bubbles with approx 5 m3 / hr Minimum Air capacity / throughput per Diffuser and Tube Type for fine bubbles with 9 m3 / hr Minimum Air capacity / throughput per DiffuserSludge Return / Relift Pump at Tube settler: Centrifugal Sludge Return / Re-lift pumps for the transfer of sludge from tubesettler to anoxic complete in all respects and as per specifications.Sludge recirculation pump at MBBR tank: Submersible type sludge recycle pump for nitrate recycle from MBBR to Anoxic complete in all respects and as per specifications.Sludge Loading/Disposal Pump: Screw Type Sludge loading / Disposal pump, complete in all respects and as per specifications. Filter Feed Pumps: In-line vertical multistage centrifugal clear water pump set of approved make, complete in all respects and as per specifications.Hydropneumatic Pumping System With Variable Frequency Drive: Supply, Installation, Testing and Commissioning of compact packaged type skid mounted, self contained variable frequency drive hydropneumatic system complete as required & as per specifications.(i) Flushing Water Supply Pumps(ii) Horticulture water supply pumpsDual media Filter: Providing and fixing vertical Dual Media Pressure Filter with suitable foundation boits & other accessories, mounting frame, complete with testing and commissioning etc.as required & as specified.Activated Carbon Filter: Providing and Fixing of Activated carbon filter as per Manufacturer's standard and testing & commissioning complete.Dosing System: Providing and fixing chemical dozing system at Anoxic tank and for centrifuge of approved make with all standard accessories & structural arrangement including suitable foundation bolts & other accessories etc. complete as required and as specified.Ultrafiltration system skid mounted type with feed pump, Cartidge filter, backwash pump, CIP system, Dosing system, UF membrane, PLC panel, Air compressor, intruments and piping, valves etcOzonation system at the clarified water tank complete as per specificationsAgitator/Hydraulic Mixture for Anoxic tank complete as per specificationsDrainage Sump Pumps: Providing and fixing compact dry motor submersible pumps of suitable rating. The pump sets shall be supplied with required accessories & as per specifications with all accessories and control system.Sludge Handling Mechanism (Centrifuge): Providing and fixing of sludge handling arrangement (Centrifuge bowl type) complete with testing & commissioning as required and as specified.UV for Supply to Flushing, Garden water outlet Line: Providing and installation of Online UV system complete with testing & commissioning as required and as specified.Sludge Trolley: Fabrication and supply of sludge trolley for transport of sludge complete as per requirements as specified.Bio media for MBBR tank and Tubesettler complete as per specificationsBar Screens: Providing and fixing manually cleaned Bar Screens, to remove coarse and fine material in the water made up of FRP complete as required and as specified, consisting of coarse screen & fine screen.PIPING AND VALVES ACCESSORIESG.I. Pipe: Provding and fixing heavy duty G.I. pipe confiming to IS. 1239 upto 150 mm and IS 3589 for dia 200 mm and above complete as required & as per specifications.uPVC Threaded Water Pipes: Providing and fixing uPVC threaded water pipes (I.S:4985-2000) Class - 5 (Min. 10 Kg/cm2) complete as required & as per specifications.Butterfly Valves: Providing & fixing butterfly valve of rating PN 16 wafer type, in cast iron body with Ductile Iron disc, EPDM seal, SS single piece shaft, conforming to IS-13095, complete as required and as specified.Ball Valves: Providing and fixing forged brass ball valve having stainless steel / brass ball tested to 25 kg/cm2 complete as required and as specified.Puddle flanges: Providing & fixing GI hot dipped puddle flanges for the tank complete as per the specificationsNon-Return Valves: Providing & fixing non return valve Dual Plate type, conforming to API-594 or IS 3512, complete as required and as specified.CONSUMABLES FOR OPERATION AND MAINTENANCESupply & Consumption of Consumables, solutions, chemicals, etc. for STP operation and maintenance upto successful commissioning of STPELECTRICAL SYSTEMSTP Panel: Design, manufacture, supply, installation, testing and commissioning of the STP panel complete as required and as specified.Aluminium Conductor: Supply of sizes of 1.1KV grade XLPE insulated and PVC sheathed aluminium conductor armoured stranded power cables conforming to IS 7098 Part-1 as ammended upto date and as specified.Supplying and making of cable end termination with brass single compression gland and Al. lug for PVC insulated and sheathed armoured cables of 1.1 K.V. aluminum conductor as required.Laying and fixing of one number XLPE /PVC insulated and PVC sheathed power of 1.1 KV grade of following sizes on surface or existing cable tray complete as required.Earthing: Earthing with GI earth plate of 600mm x 600mm x 6mm thick, including accessories and providing masonary enclosure including MS cover plate having locking arrangement and watering pipe etc. with charcoal and salt complete as required & as specified. G.I. Strip: Providing and Fixing 25 mm x 5 mm G.I. Strip in 40 mm dia. G.I. pipe from earth electrode complete as required. G.I. Strip on Surface: Providing and Fixing 25 mm x 5 mm G.I. Strip on surface or in recess for earth connection as per specifications complete as required. G.I. Wire: Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. Cable Tray: Fabrication and installation of perforated MS cable tray including horizontal and vertical bends, reducers, tees, cross-members and other accessories as required duly suspended from the ceiling with MS Suspenders and including painting with black synthetic paint as required.Rubber Mat: Providing electric insulated rubber mat non-skid type with grooved top 90 cm wide & 12 mm thk as per IS : 5424 as required suitable for 1100 volts.INSTRUMENTATION EQUIPMENTS & INSTRUMENTATION DETAILFlow Meter: Electro Magnetic Type (5nos) compatible with BMSOnline monitoring system for PH, BOD, COD and TSS.Energy Meter: -1No.Pressure Gauges:-1LotLevel Sensor-1LotLevel Gauges:-1LotTDS Meter (Digital, Microprocessor based): Hand-held -1 No.Ultrasonic Level Transmitter: Range 10 m, mounting: Integral (Tank Top)

1

-

-

... More
Raw Wate Gravity Main From Canal Intake To Sump - 350 mm dia. D.I K-7 - 2000 MProviding D.I. pipes (push on joints pressure pipes of D. I. of following class and diameters confirming to the I. S. specification inclusive cost of jointing materials (Rubber gasket of EPDM Quality ) excluding GST levied by GOI & GOM in all respect including Third party inspection charges of TPI Agency approved by MJP including Transit insurance, Railway Freight, Unloading from railway wagon,Loading into Truck, Transportation to departmental store, unloading,stacking etc. completed as directed by Engineer in charges (IS 1536/2001 for pipes and IS 158/1969 and IS 12820/1989 or latest edition/ revision with amendments for Rubber Gaskets.350 MM DIA D.I K-7

2000

-

-

... More
Providing & supplying D.I / C.I/M.S specials ( 5 % of cost of pipe shall be considered percent of specials for estimate purpose.)

1

-

-

... More
Providing double flange sluice valve confirming for IS-14846 including worn gear arrangements as per test pressure,stainless steel spindle, caps, including inspection charges, transportation upto departmental store, unloading, stacking excluding GST levied by GOI & GOM in all respect etc. complete.For Isolating valve 350 mm dia sluice valve

1

-

-

... More
80 mm dia sluice valve ( As isolating valvefor Air Valve)

5

-

-

... More
For Scour Valve 150 mm dia sluice valve

1

-

-

... More
Providing and supplying at site ductile iron / Spheroidal Graphite (S.G.) iron single / Double chamber tamper proof air valve without isolating sluice valve. Valves in accordance with BSEN 1074-4 of PN 10/16 rated,with body and bonnet of ductile iron confirming to EN 1563/IS 1865 Gr. 500/7 or Gr.400/15 floats, float guide,seat ring of stainless steel 1.4436/1.4306, seat ring gasket of WRAS approved EPDM rubber (suitable for drinking water), internal fasteners of stainless steel A2. Body & Bonnet coated inside & outside with electrostatically applied epoxy powder coated blue colour (suitable for drinking water) as per DIN 30677-2 & GSK guidelines with a coating thickness of min. 250 microns. Flange connections as per IS 1538 raised face & pressure testing at manufactures works shall be done as per IS 14845. including transportation charges excluding GST levied by GOI & GOM in all respect etc. complete. (For PN 10 & 16)80 mm dia Double Ball Air Valve

5

-

-

... More
Excavation for foundation / Pipe Trenches in earth soil of all types, sand, gravel and soft murum including removing the excavated material upto a distance of 50mtrs. And lift as below stacking and spreading as directed, manual dewatering, preparing the bed for foundation and excluding back filling etc. complete.Lift 0 to 1.50 M

300

-

-

... More
Excavation for foundation / pipe trenches in hard murum and boulders, W.B.M. road including removing the excavated material upto a distance of 50 M beyond the area and lifts as below, stacking and spreading as directed by Engineer-in-charge, normal dewatreing, preparing the bed for foundation and excluding backfilling, etc. complete.Lift 0 to 1.50 M

300

-

-

... More
Excavation for foundation / pipe trenches in soft rock and old cement and lime masonry foundation asphalt road including removing the excavated material upto a distance of 50 M beyond the area and lifts as below, stacking as directed by Engineer-incharge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (Bd-A-4/259)Lift 0 to 1.50 M

1000

-

-

... More
Excavation for foundation / pipe trenches in hard rock and concrete road by chiselling, wedging, line drilling, by mechanical means or by all means other than blasting including trimming and levelling the bed, removing the excavated material upto a distance of 50 metres beyond the area and lifts as below, stacking as directed by Engineer-in-charge, normal dewatering, excluding backfilling, etc. complete by all means. Lift 0 to 1.50 M

1400

-

-

... More
Filling in plinth and floors murum bedding in trenches with approved murum from excavated materials from foundation 15 cm to 20cm layers including watering and compaction complete.Lift 0 to 1.50 M

300

-

-

... More
Lowering laying and jointing with SBR ruber gaskets C.I. S/S pipes of various classes with CI / MS specials of following diameter in proper position, grade and alignment as directed by Engineer-in-charge including conveyance of material from stores to site of work, including cost of jointing materials and rubber rings labour, etc. complete. 350 MM DIA D.I K-7

2000

-

-

... More
Hydraulic testing of C.I./D.I. pipe line to specified pressure including cost of all materials and labour and water for testing for specified length including cutting, placing end cap making arrangement for filling safe water using reciprocating type pumps which should be able to provide specified test pressure gauges and other necessary equipments, labour, operation charges, etc. required for testing. The rate under this item shall also include cost of retesting, if necessary and reinstating to original position using water supplied by the contractor.350 MM DIA D.I K-7

2

-

-

... More
Lowering, laying and jointing in position following C.I.D/F Reflex valves, Butterfly valves and Sluice valves including cost of all labour jointing material, including nut bolts and giving satisfactory hydraulic testing etc. complete. (Rate for all class of valves.)Providing double flange sluice valve confirming for IS-14846 including worn gear arrangements as per test pressure,stainless steel spindle, caps, including inspection charges, transportation upto departmental store, unloading, stacking excluding GST levied by GOI & GOM in all respect etc. complete.For Isolating valve 350 mm dia sluice valve

1

-

-

... More
80 mm dia sluice valve ( As isolating valvefor Air Valve)

5

-

-

... More
For Scour Valve 150 mm dia sluice valve

1

-

-

... More
Providing and laying in situ following grades of Plain Cement concrete of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including normal dewatering, form work, compaction and curing, etc, complete. Use of L & T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) P.C.C M150

96.53

-

-

... More
Providing and laying in situ Cement concrete of trap/granite/quartzite/ gneiss metal for RCC work in foundation like raft, grillage, strip foundation and footing of RCC columns and steel stanchions including normal dewatering, form work, compaction, finishing and curing, etc, complete. (By weigh batching and mix design for M-250 and M-300 only. Use of L & T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) R.C.C M200

14.63

-

-

... More
Providing and fixing in position steel bar reinforcement of various diameters for RCC pipes, caps, footings, foundation, slabs, beams, columns, canopies, staircases. newels, chajjas, lintels, pardies, copings, fins, arches, etc. as per detailed designs, drawings and schedules; including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required, etc. complete. (including cost of binding wire)

0.51

-

-

... More
Providing and fixing in position air valve shaft including providing and fixing GI Medium class or 6mm thick M.S, PIPE shaft 2.70m long over branch flange of air valve tee providing PCCblock of M- 150concrete 150mm thick around the air valve tee including encasing of vertical shaft in PCC M-150 as shown in type design together with providing and making flanged ionts wherver required and fixing of air valve over the shaft excluding cost of air vavle and branch flanged air valve tee, etc. complete as per type desihn and as per directed by Engineer - in -charge for following diameters of pipe line 200 mm to 400 mm dia. Pipe line

5

-

-

... More
Providing and fixing in position M.S. Air valve boxes fabricated with 2 mm thick M.S. plate, 30 x 30 x3 mm size M.S. angle frame, concre- ting in M-150 for fixing the box in position,applying two coats of oil paint, painting chainage, locking arrangement, etc. complete as directed by Engineer-in-charge.For Double ball air valve

5

-

-

... More
Providing & costructing B.B masonry valve chamber with 15 cm thick 1: 3 :6 proportion PCC bedding ,excluding excavation ,B.B masonry in C.M 1:5 proportion precast RCC frame and cover etc. complete as directed by Engineer-in-chargeChamber size 90X90 cm

1

-

-

... More
Chamber size 120X120 cm

1

-

-

... More
Refilling the trenches with available excavated stuff with soft material first over pipeline and then hard murum material in 15cm layers with all leads and lifts including consolidation, surcharging etc. complete.

2364.4

-

-

... More
Provision for permission of road crossing / Along Road etcCharges paid To PWD for Along Road Pipe Line

1500

-

-

... More
Charges paid To PWD for Road Crossing Pipe Line

65

-

-

... More
Manufacturing, providing and supplying spirally welded /ERW/ SAW /fabricated M. S. pipes (Commercial Quality) including procurements of plates, gas cutting to required size rolling, tack welding ssembling in suitable lengths to form pipes, welding on automatic welding machine and forming ‘V’ edge on both ends of pipes including railway freight, insurance, unloading from railway wagon, loading into truck, transport to stores, unloading, tacking,excluding GST levied by GOI & GOM in all respect etc.complete as per IS - 3589 and IS-5504 as applicable as per specifications (No negative tolerance in thickness is permissible).700 mm dia. (I.D.) 10 mm thick

65

-

-

... More
Pushing of M.S. Pipe of following dia for road crossing and railway crossing by push through method in all types of stratta by using hydraulic jack and drilling machine of required diameter , below 3.0 m depth including lowering , laying , jointing of M.S. casing pipe including cost of labour , fuel and material , required welding machinery , tripod , chain pully block , crane blower etc transportation and dewatering etc complete as directed by Engineer in charge but excluding cost of M.S. pipe 500 mm dia to 1000 mm dia pipe

65

-

-

... More
Blast cleaning the surface of the old or new pipeline externally to remove all rust including providing sand machinery etc complete as directed by Engineer-in-charge.

146.95

-

-

... More
Providing and applying of elastomeric (450% elongation),thermoplastic, fire retardant, coating skin tencile strength 18 to 21 kg/cm2, antifungal, antibacterial anticorrosive, graft co-polymer coating on external pipe lines in un laid/laid condition after proper cleaning. 50 micron DFT of self bonding grade with metal surface, 50 Micron DFT of self bonding grade with metal surface, 50 Micron DFT inner coat and 50 Micron DFT of top coat.

146.95

-

-

... More
CONSTRUCTION OF SWITCH ROOM 3.40 X3.75 M SIZE and 3.40 Mx 3.75 M x 2.55 M water tank and Canal Gate. Excavation for foundation / pipe trenches in earth, soils of all types, sand, gravel and soft murum, including removing the excavated material upto a distance of 50 metres and lifts as below, stacking and spreading as directed, normal dewatering, preparing the bed or foundation and excluding backfilling, etc. complete. (Bd-A1/259)Lift 0.00 to 1.50 m.

17.15

-

-

... More
Excavation for foundation / pipe trenches in hard murum including removing the excavated material upto a distance of 50 M and lifts as below, stacking and spreading as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete.(Bd-A-2/259)

11.11

-

-

... More
Excavation for foundation / pipe trenches in hard murum and boulders, W.B.M. road including removing the excavated material upto a distance of 50 M beyond the area and lifts as below, stacking and spreading as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete.(Bd-A-3/259) Lift 1.50 to 3.00

16.66

-

-

... More
Excavation for foundation / pipe trenches in soft rock and old cement and lime masonry foundation asphalt road including removing the excavated material upto a distance of 50 M beyond the area and lifts as below, stacking as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (Bd-A4/259) Lift 1.50 to 3.00 M

5.56

-

-

... More
Excavation for foundation / pipe trenches in hard rock by controlled blasting, including trimming and levelling the bed by chiselling where necessary and removing the excavated material and stacking it in measurable heaps within a distance of 50 metres from the area and lifts as below, normal dewatering, excluding backfilling, etc.complete.(Bd-A-5/259)

5.56

-

-

... More
Providing and laying in situ Cement Concrete of trap/ granite / quartzite / gneiss metal for RCC work in foundation like raft, grillage, strip foundation and footing of RCC columns and steel stanchions including normal dewatering, form work, compaction, finishing and curing, etc. complete. (By weigh batching and mix design for M250 and M-300 only. Use of L&T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) (Excluding M.S. or Tor reinforcement)

3.01

-

-

... More
Providing and casting in situ C.C. of trap / granite/ quartzite / gneiss metal of approved quality for RCC works as per detailed drawings and designs or as directed by Engineer-in-charge including normal dewatering, centering, form work, compaction, finishing the formed surfaces with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface wherever necessary or roughening if special finish is to be provided and curing, etc. complete. (By weigh batching and mix design for M-250 and M-300 only. Use of L&T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) (Excluding M.S. or Tor reinforcement)

2.98

-

-

... More
1) Column M200

2.33

-

-

... More
2) Beam &Lintel in M200

2.52

-

-

... More
3) Chajja in M200

0.14

-

-

... More
4) slab in M200

3.88

-

-

... More
5) Pardi

8.49

-

-

... More
Providing and fixing in position steel bar reinforcement of various diameters for RCC piles, caps, footings, foundations, slabs, beams, columns, canopies, staircases, newels, chajjas, lintels, pardies, copings, fins, arches, etc. as per detailed designs, drawings and schedules; including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required, etc. complete (including cost of binding wire). (Bd-F- 17/306)

2.03

-

-

... More
Refilling the trenches with available excavated stuff with soft material first over pipeline and then hard material in 15 cm layers with all leads and lifts including consolidation, surcharging, etc. complete.

14.9

-

-

... More
Providing dry trap/ granite/ quartzite/ gneiss, rubble stone soling in 15 cm to 20 cm thick layers including hand packing and compacting, etc. complete. (Bd-A-12/264)

1.91

-

-

... More
Filling in plinth and floors / trenches with contractor's murum for bedding in 15 cm to 20 cm layers including watering and compaction, etc. complete. (Bd-A-11/263)

1.94

-

-

... More
Providing internal & External Electrification of Swith room including cost of all material & labour shown in rate analysis etc. complete.

1

-

-

... More
Providing second class Burnt Brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in foundations and plinth of inner walls/ in plinth external walls including bailing out water manually , striking joints on unexposed faces, raking out joints on exposed faces and watering etc. Complete.In Foundation & Plinth

0.71

-

-

... More
In Supper Structure

8.05

-

-

... More
Providing and fixing steel window of various sizes as per detailed drawing without hot dip zinc coating, without ventilators, including fabricating / glazing with plain / obscured glass panels of approved type and quality, iron oxidised fixtures and fastenings, finishing with oil painting two coats complete (with guard bars 12 mm square at 10 cm c/c.)

1.08

-

-

... More
Providing and fixing steel frame door of angle 50 x 50 x 6 mm with mild steel bars 16 mm dia. horizontally at 10mm c/c for ventilator portion including iron hold fast boxes for fixing shutters including welding, finishing, painting etc. complete.

1.89

-

-

... More
Providing internal cement plaster 12mm thick in single coat in cement mortar 1:4 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete.

90.53

-

-

... More
Providing neeru finish to plastered surfaces in all positions including scaffolding and curing etc. complete.

54.06

-

-

... More
Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 mm thick in cement mortar 1:4 using waterproofing compound at 1Kilogramper cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 mm thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc.complete.

54.65

-

-

... More
Providing and applying three coats of water proof cement paint of approved manufacture and of approved colour to new plastered surfaces including scaffolding if necessary, cleaning and preparing the surface, watering for two days etc. complete.

54.65

-

-

... More
Providing and applying washable oil-bound distemper of approved colour and shade to old and new surfaces in two coats including scaffolding, preparing the surfaces. (excluding the primer coat.) etc. complete

90.53

-

-

... More
Providing and laying Rough Shahabad Stone Flooring 25mm to 30mm thick and of required width in plain/ diamond pattern on a bed of 1:6 C.M. including cement float, striking joints, pointing in cement mortar 1:3 curing and cleaning etc. complete.

12.75

-

-

... More
As above of 90 x 60 cm internal size and depth upto 1.2MwithprecastR.C.Cslabcover

1

-

-

... More
Providing and supplying Canal gate construction and other work regarding gate completed. Job work

1

-

-

... More
Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 0.00 to 1.50 m.) By Manual Means

1670

-

-

... More
Providing, fixing, testing and commissioning G.I. pipe ‘C’ class ERW Heavy grade piping as per IS: 1239. The pipes being suspended from ceilings by using hi-tech supports complete with necessary specials such as tees, bends, flanges, reducers, orifice plates etc. Rate quoted shall include for painting of pipe with two coat of primer and two coats of synthetic enamel paint of approved colour/ make for above ground piping as per the NBC / IS standards and local fire service department requirement complete including supply and installation of anchor fasteners, clamps and Fabricated M.S. Structural supports . (Note : Pipes upto and 50 mm dia shall be threaded joints, above 50mm shall be welded joints.)200mm dia

30

-

-

... More
Providing, fixing, testing and commissioning G.I. pipe ‘C’ class ERW Heavy grade piping as per IS: 1239. The pipes being suspended from ceilings by using hi-tech supports complete with necessary specials such as tees, bends, flanges, reducers, orifice plates etc. Rate quoted shall include for painting of pipe with two coat of primer and two coats of synthetic enamel paint of approved colour/ make for above ground piping as per the NBC / IS standards and local fire service department requirement complete including supply and installation of anchor fasteners, clamps and Fabricated M.S. Structural supports . (Note : Pipes upto and 50 mm dia shall be threaded joints, above 50mm shall be welded joints.)150mm dia

3190

-

-

... More
Providing, fixing, testing and commissioning G.I. pipe ‘C’ class ERW Heavy grade piping as per IS: 1239. The pipes being suspended from ceilings by using hi-tech supports complete with necessary specials such as tees, bends, flanges, reducers, orifice plates etc. Rate quoted shall include for painting of pipe with two coat of primer and two coats of synthetic enamel paint of approved colour/ make for above ground piping as per the NBC / IS standards and local fire service department requirement complete including supply and installation of anchor fasteners, clamps and Fabricated M.S. Structural supports . (Note : Pipes upto and 50 mm dia shall be threaded joints, above 50mm shall be welded joints.)100mm dia

1360

-

-

... More
Providing, fixing, testing and commissioning G.I. pipe ‘C’ class ERW Heavy grade piping as per IS: 1239. The pipes being suspended from ceilings by using hi-tech supports complete with necessary specials such as tees, bends, flanges, reducers, orifice plates etc. Rate quoted shall include for painting of pipe with two coat of primer and two coats of synthetic enamel paint of approved colour/ make for above ground piping as per the NBC / IS standards and local fire service department requirement complete including supply and installation of anchor fasteners, clamps and Fabricated M.S. Structural supports . (Note : Pipes upto and 50 mm dia shall be threaded joints, above 50mm shall be welded joints.)80mm dia

715

-

-

... More
Providing, fixing, testing and commissioning G.I. pipe ‘C’ class ERW Heavy grade piping as per IS: 1239. The pipes being suspended from ceilings by using hi-tech supports complete with necessary specials such as tees, bends, flanges, reducers, orifice plates etc. Rate quoted shall include for painting of pipe with two coat of primer and two coats of synthetic enamel paint of approved colour/ make for above ground piping as per the NBC / IS standards and local fire service department requirement complete including supply and installation of anchor fasteners, clamps and Fabricated M.S. Structural supports . (Note : Pipes upto and 50 mm dia shall be threaded joints, above 50mm shall be welded joints.)65mm dia

630

-

-

... More
Providing, fixing, testing and commissioning G.I. pipe ‘C’ class ERW Heavy grade piping as per IS: 1239. The pipes being suspended from ceilings by using hi-tech supports complete with necessary specials such as tees, bends, flanges, reducers, orifice plates etc. Rate quoted shall include for painting of pipe with two coat of primer and two coats of synthetic enamel paint of approved colour/ make for above ground piping as per the NBC / IS standards and local fire service department requirement complete including supply and installation of anchor fasteners, clamps and Fabricated M.S. Structural supports . (Note : Pipes upto and 50 mm dia shall be threaded joints, above 50mm shall be welded joints.) 50mm dia

1130

-

-

... More
Providing, fixing, testing and commissioning G.I. pipe ‘C’ class ERW Heavy grade piping as per IS: 1239. The pipes being suspended from ceilings by using hi-tech supports complete with necessary specials such as tees, bends, flanges, reducers, orifice plates etc. Rate quoted shall include for painting of pipe with two coat of primer and two coats of synthetic enamel paint of approved colour/ make for above ground piping as per the NBC / IS standards and local fire service department requirement complete including supply and installation of anchor fasteners, clamps and Fabricated M.S. Structural supports . (Note : Pipes upto and 50 mm dia shall be threaded joints, above 50mm shall be welded joints.) 40mm dia

650

-

-

... More
Providing, fixing, testing and commissioning G.I. pipe ‘C’ class ERW Heavy grade piping as per IS: 1239. The pipes being suspended from ceilings by using hi-tech supports complete with necessary specials such as tees, bends, flanges, reducers, orifice plates etc. Rate quoted shall include for painting of pipe with two coat of primer and two coats of synthetic enamel paint of approved colour/ make for above ground piping as per the NBC / IS standards and local fire service department requirement complete including supply and installation of anchor fasteners, clamps and Fabricated M.S. Structural supports . (Note : Pipes upto and 50 mm dia shall be threaded joints, above 50mm shall be welded joints.) 32mm dia

710

-

-

... More
Providing, fixing, testing and commissioning G.I. pipe ‘C’ class ERW Heavy grade piping as per IS: 1239. The pipes being suspended from ceilings by using hi-tech supports complete with necessary specials such as tees, bends, flanges, reducers, orifice plates etc. Rate quoted shall include for painting of pipe with two coat of primer and two coats of synthetic enamel paint of approved colour/ make for above ground piping as per the NBC / IS standards and local fire service department requirement complete including supply and installation of anchor fasteners, clamps and Fabricated M.S. Structural supports . (Note : Pipes upto and 50 mm dia shall be threaded joints, above 50mm shall be welded joints.) 25mm dia

2860

-

-

... More
Providing coating of bitumen paint & 4mm thick wrapping for underground 100 mm ring main of fire fighting system.

490

-

-

... More
Providing coating of bitumen paint & 4mm thick wrapping for underground 150 mm ring main of fire fighting system.

2550

-

-

... More
Providing, fixing, testing & commissioning of Butterfly valve (double flanged) with C.I. body & disc, stainless steel/carbon steel shaft, Hand lever operated, PN 1.6 rating, conforming to IS:13095 / BS:5155 complete with nuts, bolts, washers, gaskets complete.150mm dia

35

-

-

... More
Providing, fixing, testing & commissioning of Butterfly valve (double flanged) with C.I. body & disc, stainless steel/carbon steel shaft, Hand lever operated, PN 1.6 rating, conforming to IS:13095 / BS:5155 complete with nuts, bolts, washers, gaskets complete.100mm dia

33

-

-

... More
Providing, fixing, testing & commissioning of Butterfly valve (double flanged) with C.I. body & disc, stainless steel/carbon steel shaft, Hand lever operated, PN 1.6 rating, conforming to IS:13095 / BS:5155 complete with nuts, bolts, washers, gaskets complete.80mm dia

41

-

-

... More
Providing and fixing forged brass lever operated Gate valve of full flow with forged brass ball (Machined to mirror smooth finish with hard chrome plated) and spindle with setting and gland of superior quality having minimum working pressure of 12 kg/cm2 etc. complete in all respect.25mm dia

125

-

-

... More
Providing and fixing forged brass lever operated Gate valve of full flow with forged brass ball (Machined to mirror smooth finish with hard chrome plated) and spindle with setting and gland of superior quality having minimum working pressure of 12 kg/cm2 etc. complete in all respect.50mm dia

33

-

-

... More
Providing and fixing cast iron double flange sluice valve complete with PN16 pressure rating, as per specification no. FF-VL/SV200 mm dia

4

-

-

... More
Providing and fixing cast iron double flange sluice valve complete with PN16 pressure rating, as per specification no. FF-VL/SV150 mm dia

4

-

-

... More
Providing and fixing cast iron double flange sluice valve complete with PN16 pressure rating, as per specification no. FF-VL/SV100mm dia

4

-

-

... More
Providing and fixing cast iron double flange sluice valve complete with PN16 pressure rating, as per specification no. FF-VL/SV80mm dia

4

-

-

... More
Providing and fixing flanged flexible connectors in SS 304 braiding, of rating PN 1.6 or equivalent, to provide stress relief for suction/delivery of pumps, complete with standard flanges, nuts, bolts etc.150mm dia (min. 150 mm length)

4

-

-

... More
Providing and fixing flanged flexible connectors in SS 304 braiding, of rating PN 1.6 or equivalent, to provide stress relief for suction/delivery of pumps, complete with standard flanges, nuts, bolts etc.100mm dia (min. 150 mm length)

28

-

-

... More
Providing and fixing flanged flexible connectors in SS 304 braiding, of rating PN 1.6 or equivalent, to provide stress relief for suction/delivery of pumps, complete with standard flanges, nuts, bolts etc.80mm dia (min. 150 mm length)

4

-

-

... More
Providing and fixing flanged flexible connectors in SS 304 braiding, of rating PN 1.6 or equivalent, to provide stress relief for suction/delivery of pumps, complete with standard flanges, nuts, bolts etc.65mm dia (min. 150 mm length)

2

-

-

... More
Providing & fixing C.I horizontal/ vertical type non return valve (dual plate) conforming to IS:5312 with C.I. body, SS Disc, SS stem, EPDM seal, complete with companion flanges, bolts, nuts, washers & inserted rubber gasket complete as required to I.S:5312, Part-I, dual plate type, class PN 2.0200 mm dia

1

-

-

... More
Providing & fixing C.I horizontal/ vertical type non return valve (dual plate) conforming to IS:5312 with C.I. body, SS Disc, SS stem, EPDM seal, complete with companion flanges, bolts, nuts, washers & inserted rubber gasket complete as required to I.S:5312, Part-I, dual plate type, class PN 2.0150 mm dia

25

-

-

... More
Providing & fixing C.I horizontal/ vertical type non return valve (dual plate) conforming to IS:5312 with C.I. body, SS Disc, SS stem, EPDM seal, complete with companion flanges, bolts, nuts, washers & inserted rubber gasket complete as required to I.S:5312, Part-I, dual plate type, class PN 2.0100mm dia

32

-

-

... More
Providing & fixing C.I horizontal/ vertical type non return valve (dual plate) conforming to IS:5312 with C.I. body, SS Disc, SS stem, EPDM seal, complete with companion flanges, bolts, nuts, washers & inserted rubber gasket complete as required to I.S:5312, Part-I, dual plate type, class PN 2.080mm dia

4

-

-

... More
Providing and Fixing Copper Alloy Air release valve, having threaded connection including the cost of 25 mm dia Gunmetal Gate valve with required fittings as per standard design.

31

-

-

... More
FIRE FIGHTING EQUIPMENTS & ACCESSORIES FOR EXTERNAL & INTERNAL HYDRANT SYSTEMProviding and fixing Stainless steel landing valve hydrants to type ‘A’ of I.S: 5290-1977 with 63mm dia. instantaneous type single headed outlet, M.S. pipe bend and flange of required size with blank caps and chain, 1.6mm thick compressed asbestos gasket of approved specifications and make, complete with instantaneous spring lock type G.M. female coupling of 63mm dia. for connecting hose pipe, complete in all respect.

123

-

-

... More
Providing and fixing standard short size Stainless steel branch pipe with hand operated gunmetal 20mm nominal bore outlet with standard instantaneous type 63mm dia coupling as per IS: 903.

123

-

-

... More
Providing and fixing first aid fire hose reel (with wall mounting swinging-type drum complying to IS:884), fitted with Thermo Plastic Synthetic Reinforced Fire Hoses conforming to IS:12585-1988 (or EN 694:2001, of Type -2 class, 20 mm bore, with standard size outlet and shut off valve, brackets, complete in all respects.

125

-

-

... More
Providing and fixing 63mm dia 15m fire hose, including Stainless steel male and female instantaneous type coupling approved by fire authority, machine wound with copper wire complete in all respects hose to IS:636 and coupling to IS: 903 with ISI certification.

246

-

-

... More
Providing and fixing standard fire mans axe with heavy duty insulated rubber handle as per IS: 926 with clamps.

123

-

-

... More
Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required:2 way-150 mm dia

17

-

-

... More
Supplying and fixing M.S./CRCA cabinet for housing single hydrant valve of size ( 400 x 400 x 400)mm or hose pipe box of size ( 600 x 600 x 200)mm made from min. 1.5 mm thick CRCA sheet with angle iron work of min. of size (25 x 25 x 4) mm having front doors with viewing glass of size (200x150) mm and locking arrangement with necessary fixing material such as rubber bidding etc. duly painted in post box red colour( Code 538 of IS 5)

35

-

-

... More
Supplying and fixing M.S./CRCA cabinet for housing Floor Hydrant valve, hose pipe, hose reel and branch pipe (size 1000 x 736 x 736 mm.) made from 16 SWG sheet and angle iron 25 x 25 x 4 mm. having front doors with viewing glass (8"x6") and locking arrangement with necessary fixing material such as rubber bidding etc. duly painted in post box red colour( Code 538 of IS 5)

108

-

-

... More
AUTOMATIC SPRINKLER SYSTEMProviding, fixing, and testing of 15mm dia. Chrome finished sprinkler head with standard response 5mm quartz bulb and to operate at 68°C (of K-Factor 5.6) complete as per given specifications.(UL Listed/FM Approved)a) Pendant/Upright Sprinklers (Standard Spray)

2800

-

-

... More
Providing,fixing and testing of 150mm dia alarm check valve (FxF) with ACV trim set to water motor alarm/gong, retard chamber, UL Listed/FM approved, complete with drain cock arrangement and with all accessories, welded or screwed as required including cutting holes and chased in brick or RCC walls and making good complete as per approved model.

2

-

-

... More
Providing and fixing inspecting, testing and drain assembly for installation on Sprinkler System, in brass body consisting of steel single lever CP ball valve for multiple test and drain functions, including inlet connection of specified size, sight glass, connections to the main header and line drain complete as per requirements to be done. Product shall suitable for min. 10 kg/cm2 working pressure and shall be UL Listed / FM Approved.50mm Drain size and 15mm (5.6K) Testing Orifice

14

-

-

... More
Providing and fixing electrically operated flow indicating switches/water flow detectors with threaded connection for indicating water flow in sprinkler branch line consisting of NEMA 4 rated enclosure for vertical/horizontal mounting, to be installed as per manufacturer specifications in an accessible location as per site, complete including wiring to monitor modules as per instructions of the engineer-in-charge, for the below pipe sizes.100 mm to 150 Dia.

14

-

-

... More
Providing and fixing electrical Monitor Modules to monitor the waterflow devices/flowswitches with built-in identification system indicating switches/waterflow detectors of 15-32v DC operating voltage to be installed as per manufacturer specifications in an accessible location as per site, complete, excluding wiring to Annunciation Panel, with UL/CE/LPCB approval.

14

-

-

... More
Providing and fixing of 2 Zones Microprocessor based conventional fire alarm control panel (FACP) with standard accessories , 16x2 Character LCD Display, provision for zone wise contact and beep sound alarm, suitable to operate on 120-220 V AC, 0 - 49 Deg C, 93 ± 2 Percentage RH (non- condensing) at 32 ± 2 Deg C complete as per specification no. FF-FAAS/FACP

1

-

-

... More
FIRE PUMPS, MECHANICAL & ELECTRICAL ACCESSORIESTERRACE FIRE PUMPSSupplying, installation, testing and commissioning of booster fire pump [BP] suitable for water discharge of 450 LPM at 35 m head driven by electric motor 415 volts, 3 phase 50 Hz, AC supply of 5.5 kW or of suitable kW capacity for manual/automatic operation and consisting of following :(a) Horizontal/vertical type, single/multi stage, centrifugal casing pump of cast iron body & bronze/CI impeller with stainless steel shaft (SS410 grade), mechanical seal conforming to IS 1520. (b) Squirrel cage induction motor, TEFC, synchronous speed 3000 RPM, suitable for operation with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325.(c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required.(d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete, as per specification no. FF-MFP/BP

2

-

-

... More
TERRACE FIRE PUMPSSupplying, installation, testing and commissioning of booster fire pump [BP] suitable for water discharge of 900 LPM at 35 m head driven by electric motor 415 volts, 3 phase 50 Hz, AC supply of 7.5 kW or of suitable kW capacity for manual/automatic operation and consisting of following : (a) Horizontal/vertical type, single/multi stage, centrifugal casing pump of cast iron body & bronze/CI impeller with stainless steel shaft (SS410 grade), mechanical seal conforming to IS 1520. (b) Squirrel cage induction motor, TEFC, synchronous speed 3000 RPM, suitable for operation on with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325. (c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required. (d)Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete, as per specification no. FF-MFP/BP

16

-

-

... More
Supplying, installation, testing and commissioning of main fire pump(MFP / EP) suitable for water discharge of 2280 to 2850 LPM at 120 to 90 m head driven by electric motor 415 volts, 3 phase 50 Hz, AC supply of 75kW or of suitable kW capacity for manual/automatic operation and consisting of following : (a) Horizontal type, single stage, centrifugal/split casing pump of cast iron body & bronze impeller with stainless steel shaft(SS410 grade), mechanical seal conforming to IS 1520. (b) Squirrel cage induction motor, TEFC, synchronous speed 3000 RPM, suitable for operation with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325. (c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete, as per specification no. FF-MFP/SSC/EP

2

-

-

... More
Supplying, installation, testing and commissioning of jockey fire pump (JP) suitable for water discharge of 180 to 240 LPM at 140 to 110 m head driven by electric motor 415 volts, 3 phase 50 Hz, AC supply of 15 kW or of suitable kW capacity for manual/automatic operation and consisting of following : (a) Horizontal/vertical type, multi stage, centrifugal casing pump of cast iron body & bronze impeller with stainless steel shaft(SS410 grade), mechanical seal conforming to IS 1520. (b) Suitable kW Squirrel cage induction motor, TEFC, synchronous speed 3000 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325. (c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003)complete, as per specification no. FF-MFP/JP

2

-

-

... More
Supplying, installation, testing and commissioning ofDiesel Engine Driven (MFP/DP) suitable for water discharge of 2280 to 2850 LPM at 120 to 90 m head driven by 110 HP or suitable HP capacity diesel engine at required working speed suitable for automatic operation and consisting of following : (a) Horizontal type, single stage, centrifugal casing pump of cast iron body & bronze impeller with stainless steel shaft(SS410 grade), mechanical seal conforming to IS 1520. (b) Water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12/24 volts DC electric starting equipment with battery of required AH capacity with necessary charger suitable to work on 230v, 50Hz AC supply, diesel tank of minimum 150ltr capacity with first filling of diesel up to 100% level with necessary piping with valves up to engine , exhaust pipe extended up to 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications etc. as required. (c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with engine assembly and accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete, as per specification no. FF-MFP/SSC/DP

2

-

-

... More
Supplying, erecting, testing & commissioning of fire pump control panel (FCP) of cubical construction, floor mounted type, fabricated from minimum 2 mm thick CRCA sheet, compartmentalised with hinged lockable doors, with enclosure protection class IP54, duly powder coated or painted with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003), cable alley, interconnection with suitable size solid copper busbar strip of adequate size for all power connections having switchgears and accessories, mountings and internal wiring with adequate size copper conductor cable, earth terminals, numbering etc. complete in all respect, suitable for satisfactory operation of main fire pump and jockey (pressurisation) pumps (1working+1standby) with necessary accessories, wiring & cabling along with allied accessories with following incoming and outgoings, suitable for automatic & manual operation on 415V, 3 phase, 50Hz ac supply as per specifications the capacity of electric motor driven pump are as follows a. Main fire pump(MFP) having capacity of 22kW 1no (1 working) b. Jockey pump(JP) capacity of suitable capacity 2 nos(1 working +1 standby, alternate run per start in auto mode) comprises of the following features & switchgears: 1. Main incomer FP SFU having rotary handle with HRC fuses of suitable rating. 2. Electrolytic grade copper strips for busbar of suitable sizes for main incomer and branches to motor SFU's, starters & outgoing terminals with necessary accessories like stainless steel nut bolts with spring washers for connections, mounted on required no of epoxy or porcelain support insulators of suitable ratings etc. 3. Individual pump TPN SFU having rotary handle with HRC fuses of suitable rating. 4. Digital voltmeter & ammeter & RYB indicating lamps & push buttons & SPP, O/L & phase reversal protection with emergency stop switch. 5. TPN SPD 100kA Type 1 +2 tested. 6. Required pressure transducer with pressure indication on panel with cabling required for monitoring & automatic operation of fire pumps. 7. System controller to control operation of main electric fire pump, jockey (pressurization) pumps in sequence with interlocking for operation of pumps as per specification with automatic/manual operation with selector switch & alternate run of standby Pumps consisting of relays, timers. sensors, annunciation window for fault indication, complete as per specification. 8.Suitable capacity electric motor starters for all individual pumps with necessary push buttons & indications. 9. Siren of required capacity to be activated when main pump starts & allied accessories as per requirements of local CFO or as directed by engineer in charge. 10. Danger board as per IS. 11. Spare HRC fuses minimum 2nos of each individual rating with required bakelite fuse holder for main & jockey fire pumps MFP=(1working), JP = (1working+1standby, alternate run per start in auto mode) complete panel, as per specification no. FF-MFP/ECP

1

-

-

... More
For addition of standby main diesel engine driven fire pump (1 standby), add as follows in the basic cost of Item no 13-5-1 towards required 12/24 v battery charger and diesel engine starter along with necessary accessories, indicators etc. with necessary interlocking and updation of control logic with interlocking for operation of pumps MFP for main (1working+1standby mode) & jockey fire pumps (1working+1standby, alternate run per start in auto mode) , add Rs....... The control for diesel engine comprises of automatic/manual selector switch & 3 attempts starting device, timers and relays as required, push buttons, start/stop in manual mode indicating lamp for high/ low Lub. oil pressure, high water temp and engine on indication battery charger suitable for 12V/24 V DC with boost and trickle selector switch, 0-30 V DC voltmeter, and 0-20 A DC ammeter with all standard relays and accessories required for automatic operation of diesel engine with interlocking for operation of main fire pumps.

1

-

-

... More
Pressure Vessel for Fire PumpSupply, Installation, Testing & Commissioning double flanged vertical air vessel fabricated from 10mm M.S. plate with dished ends from 8mm M.S. plate, outside with one coat of primer and two coats of synthetic enamel paint of approved shade, complete with approved quality and sufficient number of pressure switches, air release valve, tripod type stand, pressure gauge with ball valve, drain ball valve of 50mm dia with 2.0 meter long GI (Heavy Duty ) piping complete as required and all other required accessories to operate commonly main fire pump, diesel fire pump and Jockey pump at drop of pressure, automatically at required pressure setting (Pressure switch assembly to be fabricated at site);Recommended dia. : 250 mmHeight of shell : 1200 mmWorking pressure : 18 Kg/cm2

19

-

-

... More
Providing & erecting hot dipped galvanised ladder type cable tray manufactured from 16 SWG (1.6 mm thick) GI sheet of 150 mm width & 100 mm height comprising all required standard accessories.

200

-

-

... More
Providing & erecting hot dipped galvanised ladder type cable tray manufactured from 16 SWG (1.6 mm thick) GI sheet of 200 mm width & 100 mm height comprising all required standard accessories.

200

-

-

... More
Providing and fixing C.I double flanged "Y" type strainer with S.S. mesh, including nuts, bolts and 3 mm thick gasket complete as required200 mm dia

2

-

-

... More
150 mm dia

17

-

-

... More
Providing and fixing Pressure gauge (0-14 Kg/Cm2) with necessary flanges and fittings such as tees, elbows and painting and supports etc. complete.100mm dia

48

-

-

... More
Providing and fixing pressure switch (for operation at 0-15 Kg./sqcm) with required fittings and accessories complete.

21

-

-

... More
PORTABLE FIRE EXTINGUISHERSProviding and fixing "ABC" stored pressure type Dry Chemical Powder (Mono-Ammonium Phosphate ) fire extinguisher with fixing hangers, hose, brackets, screws to required size etc., complete as per IS: 15683:20066 Kg. Capacity

130

-

-

... More
Providing and fixing CO2 type cylindrical shape fire extinguisher with fixing hangers, hose, brackets, screws to required size etc.,complete as per IS:15683:2006 - wall mounted type.4.5 Kg. Capacity

130

-

-

... More
CIVIL WORKS FOR FIRE PROTECTION SYSTEM Steel work welded in built up sections/ framed work, including cutting,hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In stringers, treads, landings etc. of stair cases, including use of chequered plate wherever required, all complete

10200

-

-

... More
11 KV SWITCHGEAR PANELDesign, Manufacture, Supply, delivery, Installation, Testing and commissioning of following panel totally enclosed with CRCA sheet steel clad floor, mounting, epoxy based powder coating vermin proof, fully interlocked horizontal isolation, and extensible, horizontal draw out, air insulated /gas insulated, metal clad switch board having single/double isolation features, Type Tested as per latest code, complete with circuits as detailed below. The switch board would be complete with necessary insulation – silicon based Raychem or equivalent insulated copper bursars, Wiring, labels, cable eyes, cable termination to receive XLPE cables, foundation bolts and suitable for operation on 11 KV 3 phase, 50 cycle, earthed system with a rupturing capacity of 350 MVA (fault protection level18.37 KA) at 11 KV for 3 seconds.Single Panel board (11 KV) Location near 11 KV HT MeterOne Incoming/Outgoing panel equipped with the followings.1- Air insulated metal clad housing1- Set of 3 phase, insulated copper bus bars 800 Amps rating6- Single pole cluster type isolating contacts i.e. plug and switches.1- Triple pole draw out truck/cassette mounted 11 KV 350 MVA, 800 amps Vacuum circuit breaker fitted with arc control devices.1 – Trip free 240 V AC, motor charged spring release closing mechanism complete with necessary auxiliary switches, emergency hand trip device and mechanical ‘OFF’ & ‘ON’ indicators.NO/NC contacts for remote ON/OFF/TRIP status for remote switching OFF.1 – 24 Volt DC shunt trip and closing coil.1 –24 V DC Power pack with suitable backup.3 – Dual core dual ratio cast resin current transformers of ratio 100/50/5+5 Class 5P10 and Class 1.0, 15 VA burden for protection & metering.1-3 Phase cast resin horizontal draw out bus potential transformer ratio 11 KV / √3 : 110 / √3 Volt, class 1.0, 100 VA, connected star/star with H.V and L.V. connections, H.V. fuses and LV MCB of adequate rating to withstand fault level in P.T circuit, isolating plugs for H.V. and L.V. connection.1 – Strip heater to prevent absorption of moistureThe instrument and relay panel fitted with1 – Digital voltmeter scaled 0 – 15 KV with selection switch.1 – Digital Ammeter (0-150) amps with selection switch.1 no. energy analyzer of 0.5 accuracy to measure voltage, current, power factor, frequency, KW / KVA, KWH, KVArh, KVAh, Real time, date.1 – no. circuit breaker control switch for electrical (T/N/C)1 – Triple pole numerical I.D.M.T. over current & earth fault relay with two outer elements connected for over current protection and the middle element for earth fault protection over current setting 50% - 200% Earth fault setting 20% - 80% (51 and 51N)1 – Master trip relay (86)1 – Anti pumping relay (94)1 – Trip Circuit Supervision Relay - TCSR(95)1 – Set of red / green indicating lamps for close and open position with MCB.1 – Amber indicting lamp for auto trip with MCB1 – Clear indicating lamp for trip circuit healthy with MCB1 – Set of white indicating lamps one per phase with MCB1 – Blue indicating lamp for spring charged. With MCB.1 – Push button on front door for emergency trip. 1 – Push button for Test Lamp ON 1 – Surge Arrestor1- Earthing Switch6- No NO/NC Contact for OTI, WTI & Buchholz protection 1- 8 Window annunciation panel1 – Cable end box suitable for cable termination to receive Incoming and Outgoing of 3 core 240 sq.mm 11 KV XLPE cable.The switchboard shall be complete with all interconnections, label wiring, etc. as required and as per direction.

1

-

-

... More
Three Panel board (11 KV ) (Location : Substation-1)One Incoming & Two Outgoing panel equipped with the followings.Incoming1- Air insulated metal clad housing1- Set of 3 phase, insulated copper bus bars 800 Amps rating6- Single pole cluster type isolating contacts i.e. plug and switches.1- Triple pole draw out truck/cassette mounted 11 KV 350 MVA, 800 amps Vacuum circuit breaker fitted with arc control devices.1 – Trip free 240 V AC, motor charged spring release closing mechanism complete with necessary auxiliary switches, emergency hand trip device and mechanical ‘OFF’ & ‘ON’ indicators.NO/NC contacts for remote ON/OFF/TRIP status for remote switching OFF.1 – 24 Volt DC shunt trip and closing coil.1 –24 V DC Power pack with suitable backup.3 – Dual core dual ratio cast resin current transformers of ratio 150/75/5+5 Class 5P10 and Class 1.0, 15 VA burden for protection & metering.1-3 Phase cast resin horizontal draw out bus potential transformer ratio 11 KV / √3 : 110 / √3 Volt, class 1.0, 100 VA, connected star/star with H.V and L.V. connections, H.V. fuses and LV MCB of adequate rating to withstand fault level in P.T circuit, isolating plugs for H.V. and L.V. connection.1 – Strip heater to prevent absorption of moistureThe instrument and relay panel fitted with1 – Digital voltmeter scaled 0 – 15 KV with selection switch.1 – Digital Ammeter (0-150) amps with selection switch.1 no. energy analyzer of 0.5 accuracy to measure voltage, current, power factor, frequency, KW / KVA, KWH, KVArh, KVAh, Real time, date.1 – no. circuit breaker control switch for electrical (T/N/C)1 – Triple pole numerical I.D.M.T. over current & earth fault relay with two outer elements connected for over current protection and the middle element for earth fault protection over current setting 50% - 200% Earth fault setting 20% - 80% (51 and 51N)1 – Master trip relay (86)1 – Anti pumping relay (94)1- Over voltage relay.(59)1 – Trip Circuit Supervision Relay - TCSR(95)1 – Set of red / green indicating lamps for close and open position with MCB.1 – Amber indicting lamp for auto trip with MCB1 – Clear indicating lamp for trip circuit healthy with MCB1 – Set of white indicating lamps one per phase with MCB1 – Blue indicating lamp for spring charged. With MCB.1 – Push button on front door for emergency trip. 1 – Push button for Test Lamp ON 1 – Surge Arrestor1- Earthing Switch6- No NO/NC Contact for OTI, WTI & Buchholz protection 1- 8 Window annunciation panel1 – Cable end box suitable for cable termination to receive Incoming and Outgoing of 3 core 240 sq.mm 11 KV XLPE cable.ONE No. OUTGOING TRANSFORMER FEEDER EACH EQUIPPED WITH1- Air insulated metal clad housing1- Set of 3 phase, insulated copper bus bars 800 Amps rating6- Single pole cluster type isolating contacts i.e. plug and switches.1- Triple pole draw out truck/cassette mounted 11 KV 350 MVA, 800 amps Vacuum circuit breaker fitted with arc control devices.1 – Trip free 240 V AC, motor charged spring release closing mechanism complete with necessary auxiliary switches, emergency hand trip device and mechanical ‘OFF’ & ‘ON’ indicators.NO/NC contacts for remote ON/OFF/TRIP status for remote switching OFF.1 – 24 Volt DC shunt trip and closing coil.1 –24 V DC Power pack with suitable backup.3 – Dual core dual ratio cast resin current transformers of required CT ratio Class 5P10 and Class 1.0, 15 VA burden for protection & metering.1-3 Phase cast resin horizontal draw out bus potential transformer ratio 11 KV / √3 : 110 / √3 Volt, class 1.0, 100 VA, connected star/star with H.V and L.V. connections, H.V. fuses and LV MCB of adequate rating to withstand fault level in P.T circuit, isolating plugs for H.V. and L.V. connection.1 – Strip heater to prevent absorption of moistureThe instrument and relay panel fitted with1 – Digital voltmeter scaled 0 – 15 KV with selection switch.1 – Digital Ammeter (0-125) amps with selection switch.1 no. energy analyzer of 0.5 accuracy to measure voltage, current, power factor, frequency, KW / KVA, KWH, KVArh, KVAh, Real time, date.1 – no. circuit breaker control switch for electrical (T/N/C)1- Triple pole numerical I.D.M.T. over current and earth fault relay, with two outer elements connected for over current and the middle element for earth fault protection over current setting 50% - 200% Earth fault setting 20% -80% and with instantaneous element on all 3 pole settings 500-2000% on over current and 200-800% on earth fault (50, 50 N & 51, 51 N)1 – Master trip relay (86)1 – Anti pumping relay (94)1 – Trip Circuit Supervision Relay - TCSR(95)1 – Set of red / green indicating lamps for close and open position with MCB.1 – Amber indicting lamp for auto trip with MCB1 – Clear indicating lamp for trip circuit healthy with MCB1 – Set of white indicating lamps one per phase with MCB1 – Blue indicating lamp for spring charged. With MCB.1 – Push button on front door for emergency trip. 1 – Push button for Test Lamp ON 1 – Surge Arrestor1- Earthing Switch6- No NO/NC Contact for OTI, WTI & Buchholz protection 1- 8 Window annunciation panel1 – Cable end box suitable for cable termination to receive Incoming and Outgoing of 3 core 240 sq.mm 11 KV XLPE cable.The switchboard shall be complete with all interconnections, label wiring, etc. as required and as per direction. ONE No. OUTGOING TRANSFORMER FEEDER EACH EQUIPPED WITH1- Air insulated metal clad housing1- Set of 3 phase, insulated copper bus bars 800 Amps rating6- Single pole cluster type isolating contacts i.e. plug and switches.1- Triple pole draw out truck/cassette mounted 11 KV 350 MVA, 800 amps Vacuum circuit breaker fitted with arc control devices.1 – Trip free 240 V AC, motor charged spring release closing mechanism complete with necessary auxiliary switches, emergency hand trip device and mechanical ‘OFF’ & ‘ON’ indicators.NO/NC contacts for remote ON/OFF/TRIP status for remote switching OFF.1 – 24 Volt DC shunt trip and closing coil.1 –24 V DC Power pack with suitable backup.3 – Dual core dual ratio cast resin current transformers of required CT ratio Class 5P10 and Class 1.0, 15 VA burden for protection & metering.1-3 Phase cast resin horizontal draw out bus potential transformer ratio 11 KV / √3 : 110 / √3 Volt, class 1.0, 100 VA, connected star/star with H.V and L.V. connections, H.V. fuses and LV MCB of adequate rating to withstand fault level in P.T circuit, isolating plugs for H.V. and L.V. connection.1 – Strip heater to prevent absorption of moistureThe instrument and relay panel fitted with1 – Digital voltmeter scaled 0 – 15 KV with selection switch.1 – Digital Ammeter (0-30) amps with selection switch.1 no. energy analyzer of 0.5 accuracy to measure voltage, current, power factor, frequency, KW / KVA, KWH, KVArh, KVAh, Real time, date.1 – no. circuit breaker control switch for electrical (T/N/C)1- Triple pole numerical I.D.M.T. over current and earth fault relay, with two outer elements connected for over current and the middle element for earth fault protection over current setting 50% - 200% Earth fault setting 20% -80% and with instantaneous element on all 3 pole settings 500-2000% on over current and 200-800% on earth fault (50, 50 N & 51, 51 N)1 – Master trip relay (86)1 – Anti pumping relay (94)1 – Trip Circuit Supervision Relay - TCSR(95)1 – Set of red / green indicating lamps for close and open position with MCB.1 – Amber indicting lamp for auto trip with MCB1 – Clear indicating lamp for trip circuit healthy with MCB1 – Set of white indicating lamps one per phase with MCB1 – Blue indicating lamp for spring charged. With MCB.1 – Push button on front door for emergency trip. 1 – Push button for Test Lamp ON 1 – Surge Arrestor1- Earthing Switch6- No NO/NC Contact for OTI, WTI & Buchholz protection 1- 8 Window annunciation panel1 – Cable end box suitable for cable termination to receive Incoming and Outgoing of 3 core 240 sq.mm 11 KV XLPE cable.The switchboard shall be complete with all interconnections, label wiring, etc. as required and as per direction. 11KV switch Board as described above & as per specificationNote: For HT Panel, necessary coordination shall be done by the Panel Manufacturer with the vendor of Gas flooding system for fire protection, for making suitable provision in the panel at the design stage, manufacturing stage, stage of testing at works & stage of commissioning at site.

1

-

-

... More
TRANSFORMERSupplying, installation, testing and commissioning at site of 11 KV/415V, 3 phase, 50 Hz, Dyn11 step down, Delta/Star, oil cooled following Level-II transformer with On Load tap changer with +10% and -10% tappings in step of 1.25% bi-directional roller, diagram, rating plate, winding temperature indicator (WTI & OTI), Buchholz relay, silica gel breather marshalling box, lifting lugs and weather proof HT cable box, LT cable termination box etc. complete as per specification and as per IS standard. (The transformer shall comply to the latest IS & shall be subject to all test specified in specification and test certificates shall be produced on requirement). Transformer shall have trip & warning contacts, epoxy coating on transformer body, silica gel breather drain/filter valve and all necessary elements Include the first oil fill as part of the transformer.Space provision to be provided to mount the neutral CT for REF protection. CT to be provided by panel manufacturerNote transformer manufacturer has to depute his engineers at the time of installation of transformer for supervision. Note: transformer manufacturer has to depute his engineers at the time of installation of transformer for supervision. Transformer Oil shall be transported in drum & first oil fill shall be as part of the transformer1250 KVA

2

-

-

... More
Compact SubstationSupply, receiving, storing, inspection, handling, assembling, installation in correct aligned position, effecting proper connections, testing and commissioning of Outdoor type package type substation with continuous rating 1000 KVA, Step Down, 11/0.433 kV oil filled On load tap changer, transformer with 4 mm thick base and 2 mm thick wall of each compartment with compartment, with IP 54 for HT & LT compartment and IP 23 for transformer compartment, with naturally cooled type canopy (Hot Galvanized Steel), required capacity power pack and the following specifications confirming to IS: 2026 & ECBC. PSS shall have sufficient space on top of canopy to dissipate heat generated from transformer.Package substation will have the following equipment but not limited to -RMU-Extensible 2 WAY, 11 KV (1 Isolators, 1 SF6 circuit breaker),TYPE:- Free standing, Metal Clad, SF6 insulated Ringmaster with 1Nos 630A load breaking, Fault Breaking Switches and 630A T off SF6 Circuit Breaker.Self-Powered Relay : Type IDMTRing switches and T OFF SF6 circuit breaker with Integrated Earthing SwitchesLive Cable Indicator for Ring Switches- ProvidedPadlocking Facility-ProvidedShunt trip coil rating- 230V AC. Padlocking facilityAll civil works such as PCC/RCC foundation, Platform, Fencing, Filling trench and pedestals etc. will remain in civil scope.11KV/433V, hermetically sealed 1000 kVA (Level -II as per IS & its latest ammendment) three phase, Dyn11, ON load tap changer with +10% to -10% in steps of 1.25% on HT side, CU winding, Oil type, Transformer with standard accessories. LV Compartment :-Outgoing:-1No. 4 Pole, 1600A, 50KA microprocessor base MDO ACB with O/C,S/C & E/F Protection1000 KVA Package Type Substation as described above:-

1

-

-

... More
DISTRIBUTIONS PANELS MAIN LT PANEL SUBSTATION-1 LT PANELSDesign, Manufacturing, testing at works supply and delivery of floor mounting, free standing, totally enclosed indoor cubical, extensible compartmentalized front operational, vertical panel fabricated out of 2 mm thick CRCA sheet steel provided with hinged detachable lockable, front and back openable individual chamber doors including strengthening with angle iron frame work complete as required. The panel shall be powder coated and suitable for the following mountings: Note : The following provisions shall be required to be made in the switchboard detailed below:The switchboard shall be have provision for entry of all cables / bus duct from the top / bottom as required.All live accessible parts shall be shrounded and all equipment shall be finger touch proof. The busbar insulation shall be with heat shrinkable sleeves. SMC/DMC shrounds and bus bar supports shall be used.Suitable tinned copper extension links for incoming/outgoing cables shall be provided wherever required.Control circuits includes breaker control switch, auto manual selector switch, anti plumbing relay, spring charging trip indication Timer, control wiring, Auxiliary contactors MCB's as required at site.All the incomers breakers shall be interlocked to avoid parallel operation.All transformer's incomers having microprocessor breakers, shall have neutral CT and shall be compatible to MODBUS/RS-485 communication ports required.All ACB, fault level breaking capacity indicates Ics value at 415 volts. (Ics = Icu = Icw = 100%) for 1 sec.All MCCB upto 250 Amp shall have adjustable tharmal & fixed magnatic setting if not specified in BOQ. Above 250 Amp tharmal & magnatic both setting should be adjustable. For all MCCB Isc =100% IcuMCCB's in the MAIN LT Panel shall be with inbuilt Microprocessor based overload and short circuit & Earth fault release as per BOQ .All MCCB's shall have thermal magnetic release. All ACB upto 2500Amp shall have same frame size & should not derate upto 50 degree Celsius. All ACB's shall have all standard accessories such as CT's Arc Chute, Safety shutters etc.Link and drops from ACB/MCCB shall be designed for full rated current of ACB/MCCB rating at same amount of current density as of main bus bar.Space heater/light/air filter shall be provided for each vertical compartment. All CT's shall have same fault level rating as their respective circuit breaker. Bus bar size/rating, type of insulator, size of insulator, support for insulator, spacing of busbar support shall be as per CPRI approved design. ACB Shall have OEM provided extended link for Bus bar connectionMain LT Panel - Substation-1DG INCOMING-1 & 4 (500 KVA)Two (2) No. 500 KVA DG incomer each consisting of 800A, FP EDO type ACB (50 KA) with microprocessor based O/L, S/C and E/F releases. Metering Indication & Protection. Microprocessor release having inbuilt overload protection with time delay, short circuit protection with time delay, instantaneous alongwith earthfault protection. 3 nos Cast resin current transformers of 800/5 ratio Class 1.0 for metering. Square flush mounting 0-800amp analog ammeter with 3 way and OFF selector switch. Square flush mounting 0-500V analog Voltmeter with selector switch. 1 no.Multi function Meter (MFM) with RS 485 port of 1.0 accuracy to measure voltage, current, power factor, frequency, KW , KVA, KWH, KVAh. 6 nos NO/NC contacts for remote opening & closing. ON/OFF/TRIP indicating lamps1 set of three White phase indicating lamps (RYB). Under voltage relay. Over Voltage Relay. Terminals to receive XLPE CablesDG INCOMING-2 &3 (750 KVA)Two (2) No. 750 KVA DG incomer each consisting of 1250A, FP EDO type ACB (50 KA) with microprocessor based O/L, S/C and E/F releases. Metering Indication & Protection. Microprocessor release having inbuilt overload protection with time delay, short circuit protection with time delay, instantaneous alongwith earthfault protection. 3 nos Cast resin current transformers of 1250/5 ratio Class 1.0 for metering. Square flush mounting 0-1250amp analog ammeter with 3 way and OFF selector switch. Square flush mounting 0-500V analog Voltmeter with selector switch. 1 no.Multi function Meter (MFM) with RS 485 port of 1.0 accuracy to measure voltage, current, power factor, frequency, KW , KVA, KWH, KVAh. 6 nos NO/NC contacts for remote opening & closing. ON/OFF/TRIP indicating lamps. 1 set of three White phase indicating lamps (RYB). Under voltage relay. Over Voltage Relay. Terminals to receive XLPE CablesDG INCOMING-5 (125 KVA) with 1 no. 200 Amps, 690 volt 25 KA, 4 pole MCCB each complete with microprocessor base overcurrent, earth fault releases with 400A 4P, AC-III duty Contactor. The MCCB shall be provided with microprocessor based release having variable range of over current, short circuit and earth fault protection with time lag facility for each of the fault for achieving discrimination.The Indicating panel of each incomer MCCB shall be provided with the following : 1 no.Multi function Meter (MFM) with RS 485 port of 1.0 accuracy to measure voltage, current, power factor, frequency, KW , KVA, KWH, KVAh. 6 nos NO/NC contacts for remote opening & closing 3 Nos. phase indicating lamps backed up with MCB. ON/OFF/Trip indicating lamps. Under voltage relay, Over Voltage RelayTerminals to receive XLPE CablesINCOMING -6 & 7 (1250 KVA Transformer)Transformer Incomer : Two (2) No. 1250 KVA Transformer incomer each consisting of : 2000A, FP EDO type ACB (50 KA) with microprocessor based O/L, S/C and E/F releases. Metering, Indication & Protection: (1 Set)1 No. Multifunction digital meter (consisting of Voltage, Current, Frequency, PF, kWh, kVA THD parameter) analyser with RS-485 Port.1 No. of 2000/5A, CL-1, 10VA measuring CTs.1 No. of phase indicating lamps with MCB.1 No. of ON/OFF/Trip/Trip circuit healthy/ready to close lamps. 1 No. 2000/5A, CL-1, 10VA CT for APFCR.1 No. of restricted earth fault relay with 2000/5A, CL-PS, CTs (3 Nos. to be mounted in panel and 1 No. to be supplied loose).1 No. of Voltage Transformer 415/110V AC, 100VA with control MCBs.Under voltage relay (27), Over voltage relay(59), Trip circuit supervision relay(TCSR), Master trip lockout relay(86), Surge Arrestor complete in all respect as required.BUSBAR"Electrolytic high conductivity aluminium three phase and neutral busbars having a maximum current density of 1 amp per sq mm suitable to with stand symmetrical fault level of 50 kA at 415 volts. The neutral busbar is to be of 50% capacity. Busbar-2500 AMP"BUS COUPLER-1800A, FP EDO type ACB (50 KA) with microprocessor based O/L, S/C and E/F releases.6 nos NO/NC contacts Red/Green/amber ON/OFF/spring charge indicating lampsBUS COUPLER-22000A, FP EDO type ACB (50 KA) with microprocessor based O/L, S/C and E/F releases.6 nos NO/NC contacts Red/Green/amber ON/OFF/spring charge indicating lampsBUS COUPLER-32000A, FP EDO type ACB (50 KA) with microprocessor based O/L, S/C and E/F releases.6 nos NO/NC contacts Red/Green/amber ON/OFF/spring charge indicating lampsBUS COUPLER-41 no. 200 Amps, 690 volt 25 KA, 4 pole MCCB each complete with microprocessor base overcurrent, earth fault releases with 400A 4P, AC-III duty Contactor 6 nos NO/NC contacts ON/OFF charge indicating lampsOUTGOINGNote : Each outgoing feeder shall have following 1 set of ON/OFF indicating lamps3 nos Cast resin type Class 1.0, 15 VA Burden CT's for metering. CT Ratio as per breaker ratingDigital electronic ammeter2 nos 800 amps 690 volt 50 kA FP MCCB with Microprocessor based overload and short circuit & Earth fault release4 nos 630 amps 690 volt 50 kA FP MCCB with Microprocessor based overload and short circuit & Earth fault release10 nos 400 amps 690 volt 50 kA FP MCCB with Microprocessor based overload and short circuit & Earth fault release2 nos 300 amps 690 volt 50 kA FP MCCB with Microprocessor based overload and short circuit & Earth fault release2 nos 100 amps 690 volt 50 kA FP MCCB with Microprocessor based overload and short circuit & Earth fault releaseLoad management & AMF operation of 2x750KVA, 2x500KVA & 125 KVA DG SetMannual mode8 Sets of 3 indication lamps “Load on set” “load on mains” “Set fails start”Emergency stop push button for each DG set & transformer Engin start stop push button for each DG SetPLC/Mannual selector switch8 Window announcitor for each DG set faultsPLC shall be provided for each DG stet1no. common hooterEngin Start/StopAutomatic start of the DG set during failure of power supply. Automatic stopping after restoration of power supply.Indication for “Load on set” “Load on Mains” “Set fails starts” Low oil pressure” “High water Temp” “Overspeed” “Low fuel”The PLC shall provide auto mains failure, auto changeover, auto load management for 5No DG sets (2x750KVA, 2x500KVA & 125 KVA) DG sets, 2 No. transformer incomer, 4No. buscouplers by automatic closing & opening of the mains, alternator & bus section circuit breaker. (PLC should be extensible to accomodate additional logic for +1 DG Set)Main processor unitDigital input modules as required Digital output modules as required EEPROMAux. contactor & relays as requiredSuitable size of UPS for proper funtionality of the panel with minimum 50 % additional capacity.INTERLOCKINGThe Bus Couplers and Incoming ACB's/ Contactors shall be mechanically & electrically interlocked such that the Transformers cannot be paralleled with DG Sets. In addition to the above a micro PLC shall be provided for controlling the operation of Incoming breaker & buscoupler with 60 minute power backupThe Switchboard shall be complete with all interconnections, risers, internal wiring, labels etc complete as required

1

-

-

... More
CAPACITOR SWITCHBOARDS-350 kVARINCOMINGDirect cable connection to the Busbars, 3 nos Cast resin current transformers of 800/5 ratio Class 1.0 for metering, Digital electronic ammeter 800 amps, 1 set of three White phase indicating lamps, Terminals to receive XLPE cables, 16 step automatic power factor correction relay to sense and monitor the system power factor and provide impulses for operation of 14 capacitor circuits as below.BUSBARSElectrolytic high conductivity aluminium three phase busbars rated at 800 amps having a maximum current density of 1 amp per sq mm suitable to with stand symmetrical fault level of 35 KA at 415 volts.OUTGOINGS5No. - 160 amp 50 KA TP MCCB complete each with the following:- 3 pole capacitor grade contactor suitable for automatic switching of 50 kVAR capacitor bank with 14% detuned reactors, On/Off Indicating lamp, On/Off Push Button, Manual/auto changeover switch, 50 kVAr hermetically sealed metallized polypropylene capacitor units complete with fuse protection, discharge resistors, interconnections etc complete as required. 3 No. - 63 amp 25 KA TP MCCB complete each with the following:- 3 pole capacitor grade contactor suitable for automatic switching of 25 kVAR capacitor bank with 14% detuned reactors, On/Off Indicating lamp On/Off Push Button, Manual/auto changeover switch, 25 kVAr hermetically sealed metallized polypropylene capacitor units complete with fuse protection, discharge resistors, interconnections etc complete as required. 1No- 40 amp 25 KA TP MCCB complete each with the following:- 3 pole capacitor grade contactor suitable for automatic switching of 15 kVAR capacitor bank with 14% detuned reactors, On/Off Indicating lamp, On/Off Push Button, Manual/auto changeover switch, 15 kVAr hermetically sealed metallized polypropylene capacitor units complete with fuse protection, discharge resistors, interconnections etc complete as required. 2No. - 25 amp 25 KA TP MCCB complete each with the following:- 3 pole capacitor grade contactor suitable for automatic switching of 10 kVAR capacitor bank with 14% detuned reactors, On/Off Indicating lamp, On/Off Push Button, Manual/auto changeover switch, 5 kVAr hermetically sealed metallized polypropylene capacitor units complete with fuse protection, discharge resistors, interconnections etc complete as required. The Switchboard shall be complete with all interconnections, risers, internal wiring, labels etc. complete as required

2

-

-

... More
Main LT Panel - Substation-2DG INCOMING-1 & 2 (500 KVA)Tow (2) No. 500 KVA DG incomer each consisting of 800A, FP EDO type ACB (50 KA) with microprocessor based O/L, S/C and E/F releases. Metering Indication & Protection, Microprocessor release having inbuilt overload protection with time delay, short circuit protection with time delay, instantaneous along with earth fault protection., 3 nos Cast resin current transformers of 800/5 ratio Class 1.0 for metering, Square flush mounting 0-800amp analog ammeter with 3 way and OFF selector switch, Square flush mounting 0-500V analog Voltmeter with selector switch, 1 no.Multi function Meter (MFM) with RS 485 port of 1.0 accuracy to measure voltage, current, power factor, frequency, KW , KVA, KWH, KVAh. 6 nos NO/NC contacts for remote opening & closing, ON/OFF/TRIP indicating lamps, 1 set of three White phase indicating lamps (RYB), Under voltage relay, Over Voltage Relay, Terminals to receive XLPE CablesDG INCOMING-3 (125 KVA) with 1 no. 200 Amps, 690 volt 25 KA, 4 pole MCCB each complete with microprocessor base overcurrent, earth fault releases with 400A 4P, AC-III duty Contactor, The MCCB shall be provided with microprocessor based release having variable range of over current, short circuit and earth fault protection with time lag facility for each of the fault for achieving discrimination. The Indicating panel of each incomer MCCB shall be provided with the following : 1 no.Multi function Meter (MFM) with RS 485 port of 1.0 accuracy to measure voltage, current, power factor, frequency, KW , KVA, KWH, KVAh. 6 nos NO/NC contacts for remote opening & closing, 3 Nos. phase indicating lamps backed up with MCB. ON/OFF/Trip indicating lamps. Under voltage relay, Over Voltage Relay, Terminals to receive XLPE Cables, 1 No. of phase indicating lamps with MCB. TRANSFORMER INCOMING -4 (1000 KVA Transformer)Transformer Incomer : One (1) No. 1000 KVA Transformer incomer each consisting of :1600A, FP EDO type ACB (50 KA) with microprocessor based O/L, S/C and E/F releases.Metering, Indication & Protection: (1 Set)1 No. Multifunction digital meter (consisting of Voltage, Current, Frequency, PF, kWh, kVA THD parameter) analyser with RS-485 Port.1 No. of 1600/5A, CL-1, 10VA measuring CTs.1 No. of phase indicating lamps with MCB.1 No. of ON/OFF/Trip/Trip circuit healthy/ready to close lamps. 1 No. 1600/5A, CL-1, 10VA CT for APFCR.1 No. of restricted earth fault relay with 1600/5A, CL-PS, CTs (3 Nos. to be mounted in panel and 1 No. to be supplied loose).1 No. of Voltage Transformer 415/110V AC, 100VA with control MCBs.Under voltage relay (27)Over voltage relay(59)Trip circuit supervision relay(TCSR)Master trip lockout relay(86)Surge Arrestor complete in all respect as required.BUSBAR"Electrolytic high conductivity aluminium three phase and neutral busbars having a maximum current density of 1 amp per sq mm suitable to with stand symmetrical fault level of 50 kA at 415 volts. The neutral busbar is to be of 50% capacity. Busbar-1600 AMP"BUS COUPLER-1800A, FP EDO type ACB (50 KA) with microprocessor based O/L, S/C and E/F releases.6 nos NO/NC contacts Red/Green/amber ON/OFF/spring charge indicating lampsBUS COUPLER-21 no. 200 Amps, 690 volt 25 KA, 4 pole MCCB each complete with microprocessor base overcurrent, earth fault releases with 400A 4P, AC-III duty Contactor 6 nos NO/NC contacts ON/OFF charge indicating lampsOUTGOINGNote : Each outgoing feeder shall have following:- 1 set of ON/OFF indicating lamps, 3 nos Cast resin Class 1.0, 15 VA Burden required rating CT's for metering, Digital electronic ammeter2 no. 630 amps 690 volt 25 kA FP MCCB with Microprocessor based overload and short circuit & Earth fault release1 no. 400 amps 690 volt 25 kA FP MCCB with Microprocessor based overload and short circuit & Earth fault release5 nos 300 amps 690 volt 25 kA FP MCCB with Microprocessor based overload and short circuit & Earth fault release2 nos 250 amps 690 volt 25 kA FP MCCB with Microprocessor based overload and short circuit & Earth fault release3 nos 160 amps 690 volt 25 kA FP MCCB with Microprocessor based overload and short circuit & Earth fault release5 nos 125 amps 690 volt 25 kA FP MCCB with Microprocessor based overload and short circuit & Earth fault release4 nos 100 amps 690 volt 25 kA FP MCCB with Microprocessor based overload and short circuit & Earth fault release4 nos 63 amps 690 volt 25 kA FP MCCB with Microprocessor based overload and short circuit & Earth fault release4 nos 40 amps 690 volt 25 kA FP MCCB with Microprocessor based overload and short circuit & Earth fault releaseLoad management & AMF operation of 2No. 500KVA & 125KVA DG SetManual mode8 Sets of 3 indication lamps “Load on set” “load on mains” “Set fails start”Emergency stop push button for each DG set & transformer Engine start stop push button for each DG SetPLC/Manual selector switch8 Window annunciator for each DG set faultsPLC shall be provided for each DG stet1no. common hooterEngine Start/StopAutomatic start of the DG set during failure of power supply. Automatic stopping after restoration of power supply.Indication for “Load on set” “Load on Mains” “Set fails starts” Low oil pressure” “High water Temp” “Overspeed” “Low fuel”The PLC shall provide auto mains failure, auto changeover, auto load management for 3No DG sets (2No 500KVA & 125KVA) DG sets, 1 No. transformer incomer, 1No. bus couplers by automatic closing & opening of the mains, alternator & bus section circuit breaker. (PLC should be extensible to accommodate additional logic for +1 DG Set)Main processor unit, Digital input modules as required, Digital output modules as required EEPROMAux. contactor & relays as required. Suitable size of UPS for proper functionality of the panel with minimum 50 % additional capacity.INTERLOCKINGThe Bus Couplers and Incoming ACB's/ Contactors shall be mechanically & electrically interlocked such that the Transformers cannot be paralleled with DG Sets. In addition to the above a micro PLC shall be provided for controlling the operation of Incoming breaker & bus coupler with 60 minute power backup. The Switchboard shall be complete with all interconnections, risers, internal wiring, labels etc complete as required

1

-

-

... More
CAPACITOR SWITCHBOARDS-300kVARINCOMINGDirect cable connection to the Busbars3 nos Cast resin current transformers of 600/5 ratio Class 1.0 for meteringDigital electronic ammeter 500 amps 1 set of three White phase indicating lamps Terminals to receive XLPE cables 8 step automatic power factor correction relay to sense and monitor the system power factor and provide impulses for operation of 14 capacitor circuits as below.BUSBARSElectrolytic high conductivity aluminium three phase busbars rated at 500 amps having a maximum current density of 1 amp per sq mm suitable to with stand symmetrical fault level of 35 KA at 415 volts. OUTGOINGS5No. - 160 amp 50 KA TP MCCB complete each with the following3 pole capacitor grade contactor suitable for automatic switching of 50 kVAR capacitor bank with 14% detuned reactorsOn/Off Indicating lampOn/Off Push ButtonManual/auto changeover switch50 kVAr hermetically sealed metallized polypropylene capacitor units complete with fuse protection, discharge resistors, interconnections etc complete as required.1No. - 63 amp 25 KA TP MCCB complete each with the following3 pole capacitor grade contactor suitable for automatic switching of 25 kVAR capacitor bank with 14% detuned reactorsOn/Off Indicating lampOn/Off Push ButtonManual/auto changeover switch25 kVAr hermetically sealed metallized polypropylene capacitor units complete with fuse protection, discharge resistors, interconnections etc complete as required.1No- 40 amp 25 KA TP MCCB complete each with the following3 pole capacitor grade contactor suitable for automatic switching of 15 kVAR capacitor bank with 14% detuned reactorsOn/Off Indicating lampOn/Off Push ButtonManual/auto changeover switch15 kVAr hermetically sealed metallized polypropylene capacitor units complete with fuse protection, discharge resistors, interconnections etc complete as required.1No. - 32 amp 25 KA TP MCCB complete each with the following3 pole capacitor grade contactor suitable for automatic switching of 10 kVAR capacitor bank with 14% detuned reactorsOn/Off Indicating lampOn/Off Push ButtonManual/auto changeover switch10 kVAr hermetically sealed metallized polypropylene capacitor units complete with fuse protection, discharge resistors, interconnections etc complete as required.The Switchboard shall be complete with all interconnections, risers, internal wiring, labels etc. complete as required

1

-

-

... More
SDB-for Dean Residence (Outdoor Type)Incoming:One (1) No. 125A, 4P MCCB (25kA) with thermal magnetic releases and ON/OFF/Trip indicating lamps.Metering & Indication:Combined Ammeter/Voltmeter with Selector Switch and 125/5A, CL-1, 10VA CTs and 2A control MCB.Sets of phase indicating lamp with 2A control MCBs.Bus Bar:Electrolytic high conductivity aluminium three pole and neutral busbars rated at 300 amps(after deration) having a maximum current density of 0.8 amp per sq mm insulated with heat shrinkable PVC sleeves.Outgoing:6 No. 40 Amp TPN MCB, 25 KA.Two (2) No. 25 Amp DP MCB, 10 KA.Panel described as above

3

-

-

... More
Common Service Panel (SS-1)Incoming:One (1) No. 300A, 4P MCCB (35kA) with thermal magnetic releases and ON/OFF/Trip indicating lamps.Metering & Indication:Combined Ammeter/Voltmeter with Selector Switch and 300/5A, CL-1, 10VA CTs and 2A control MCB.Sets of phase indicating lamp with 2A control MCBs.Bus Bar:Electrolytic high conductivity aluminium three pole and neutral busbars rated at 300 amps(after deration) having a maximum current density of 0.8 amp per sq mm insulated with heat shrinkable PVC sleeves.Outgoing:1 No. 160 Amp TPN MCCB, 25 KA.10 No. 63 Amp TPN MCCB, 25 KA.6 No. 40 Amp TPN MCB, 25 KA.Two (2) No. 25 Amp DP MCB, 10 KA.Panel described as above

1

-

-

... More
Common Service Panel (SS-2)Incoming:One (1) No. 250A, 4P MCCB (35kA) with thermal magnetic releases and ON/OFF/Trip indicating lamps.Metering & Indication:Combined Ammeter/Voltmeter with Selector Switch and 300/5A, CL-1, 10VA CTs and 2A control MCB.Sets of phase indicating lamp with 2A control MCBs.Bus Bar:Electrolytic high conductivity aluminium three pole and neutral busbars rated at 300 amps(after deration) having a maximum current density of 0.8 amp per sq mm insulated with heat shrinkable PVC sleeves.Outgoing:1 No. 125 Amp TPN MCCB, 25 KA.5 No. 63 Amp TPN MCB, 10 KA.5 No. 40 Amp TPN MCB, 25 KA.Two (2) No. 25 Amp DP MCB, 10 KA.Panel described as above

1

-

-

... More
FEEDER PILLARSupply installation, testing and commissioning of outdoor, double door type, front operated, front access, totally enclosed, free standing, dust and vermin proof feeder pillars with double door, IP-56 ingress protection, fabricated from 2/1.6 mm thick CRCA sheets, with hinged, gasketted and lockable doors including the cost of interconnections, copper crimping lugs, brass glands, bonding to earth and painting, suitable for use at 415 volts, 3phase 4 wire 50Hz system with 15MVA rupturing capacity at 415 volts complete as per specifications and as below.All live accessible parts shall be shrouded and all equipment shall be finger touch proof. The busbar insulation shall be with heat shrinkable sleeves. SMC/DMC shrouds and busbar supports shall be used. Padlocking facility and suitable MS frame with front cover sheet shall be provided.FEEDER PILLAR (Type-1)INCOMING1 no. 63 Amps TPN MCBBUS BARElectrolytic high conductivity aluminium three phase and neutral busbars rated at 100 amps having a maximum current density of 1 amp per sq mm suitable to with stand symmetrical fault level of 10 KA at 415 volts. The neutral busbar is to be of 100% capacity.INDICATING PANELThe incomers shall have the following indicating panel 3 nos Cast resin current transformers of 100/5 ratio Class 1.0 for metering1 no ammeter of 96 mm sq scaled 0-100 amps with 3 way and OFF selector switch1 no voltmeter of 96 mm sq scaled 0- 500 volts with 3 way & OFF selector switch1 set of indicating lamps (ON. OFF) 1 set of phase indicating lampsOUTGOINGS 4 nos. 20 Amps 10 KA FP MCB 4 nos. 20 Amps 10 KA DP MCB 3 nos 32 amp 10 kA DP MCB with thermal magnetic protective releases each with 32 DP amp Contactor each with Dual setting 24 hour calibrated time switch for automatic operation of the supply, each with 8 nos per circuit 10 amp SP 10 kA MCB's as outgoing.The Feeder Pillar shall be complete with all interconnections, busbars etc. complete as per design to be approved by the Architects.

2

-

-

... More
FEEDER PILLAR (Type-2)INCOMING1 no. 100 Amps TPN MCCBBUS BARElectrolytic high conductivity aluminium three phase and neutral busbars rated at 100 amps having a maximum current density of 1 amp per sq mm suitable to with stand symmetrical fault level of 10 KA at 415 volts. The neutral busbar is to be of 100% capacity.INDICATING PANELThe incomers shall have the following indicating panel 3 nos Cast resin current transformers of 100/5 ratio Class 1.0 for metering1 no ammeter of 96 mm sq scaled 0-100 amps with 3 way and OFF selector switch1 no voltmeter of 96 mm sq scaled 0- 500 volts with 3 way & OFF selector switch1 set of indicating lamps (ON. OFF) 1 set of phase indicating lampsOUTGOINGS 2 nos. 40 Amps 10 KA FP MCB 2 nos. 20 Amps 10 KA FP MCB 3 nos 40 amp 10 kA DP MCB with thermal magnetic protective releases each with 32 DP amp Contactor each with Dual setting 24 hour calibrated time switch for automatic operation of the supply, each with 8 nos per circuit 10 amp SP 10 kA MCB's as outgoing. The Feeder Pillar shall be complete with all interconnections, busbars etc. complete as per design to be approved by the Architects.

2

-

-

... More
Fire SuppressionAutomatic Fire Extinguisher for Electrical Panel - Automatic Direct Low Pressure Fire Suppression. Extinguisher and Valve for fowing Electrical Panel with Clean Agent NOVEC-1230 type fire extinguisher of 2 Kgs with End of Line Adaptor with Pressure Gauge to monitor Pressure in the tube, Tube Attachment for UL Listed Fire Detection Tube, UL Listed Fire Detection Tube for automatic fire suppression system, Pressure Switch shall be given with Cylinder and it shall be connected to Master Control Unit with A/V Alarm for indication while activation of system, Mounting Brackets and Triangle type Auto Glow fire extinguisher sign board etc.complete confirming to IS Standards and as per technical specification with all mounting accessories complete as required. Fire extinguisher and required connectors and associated Tube of required Length. UL Listed Fire Detection Tube and accessories connection from cylinder to the inside of the panel.Main LT Panel (Approx Dimensions 9Mx1.5Mx2.4M)

1

-

-

... More
Main LT Panel (Approx Dimensions 6Mx1.5Mx2.4M)

1

-

-

... More
Capacitor Panel (Approx Dimensions 2.5Mx1.5Mx2.4M)

2

-

-

... More
Capacitor Panel (Approx Dimensions 1.5Mx1.5Mx2.4M)

1

-

-

... More
MDB/SDBs (Approx Dimensions 2.5Mx0.6Mx2.1M)

18

-

-

... More
Supply of Rubber hand gloves suitable for 11KV.

4

-

-

... More
Supply & fixing of glass framed shock treatment chart both in Hindi & English for treating person suffering due to electric shock mounted on wall hooks.

4

-

-

... More
Providing and fixing H.T. danger notice plate of 250 mm x 200mm, made of mild steel at least 2mm thick and vitreous enamelled white on both sides and with inscription in single red colour on front side as required.

4

-

-

... More
Providing and fixing M.V. danger notice plate of 200 mm x 150mm, made of mild steel at least 2mm thick and vitreous enamelled white on both sides and with inscription in single red colour on front side as required.

40

-

-

... More
Providing & fixing of Carbon dioxide (CO2) type fire extinguishers conforming to IS 2878-1976 and cylinder fully charged of 4.5 Kg capacity hanged on wall with bracket component as required..

20

-

-

... More
Supply and fixing safety instruction chart in word duly framed with 5mm thick glass required. (Approx. Front area 1.20 sq.mt.)

20

-

-

... More
Providing of set of 4 Nos. 9.5 Litre capacity GI bucket painted in post office red colour with prior coat of red - oxide paint and written with white paint 'Fire' and mounted on MS angle iron frame with bracket of appropriate size and capacity including filling sand etc.

4

-

-

... More
First Aid box as approved by St. John Ambulance Brigade / Indian red Cross conforming to IS 2217 -1963

20

-

-

... More
Supply & fixing of fire retardant / extinguishing Electrical insulated synthetic mat of 2.0 mm thick +/- 10% confirming to BIS: DOC NO. ET-02 (5440) meeting requirements of IS: 15652 :2006 (with upto date amendment), suitable for all voltages not exceeding 3.3 KV and having minimum width of 1000 mm +/-20mm and including supply of required quantity of adhesive/ compound and fixing the same at size as per site requirements.

200

-

-

... More
Supply & fixing of fire retardant / extinguishing Electrical insulated synthetic mat of minimum 3.0 mm thick +/- 10% confirming to BIS: DOC NO. ET-02 (5440) meeting requirements of IS: 15652 :2006 (with upto date amendment),, suitable for all voltages not exceeding 33 KV and having minimum width of 1000 mm +/- 20mm and including supply of required quantity of adhesive/ compound and fixing the same at size as per site requirements.

20

-

-

... More
8 Watt Up Lighters, polyester coated aluminium, suitable for housed in ground/ bushlight.(Make- Wipro, Model No. :Gardenia LF05-600-036-27-XX or equivalent in Crompton/ Havells)

400

-

-

... More
7 Watt COB Spike Light, suitable for outdoor application(Make- Wipro, Model No. : Garnet D930727 or equivalent in Crompton/ Havells)

350

-

-

... More
Step Light - 7 Watt IP 65 LED Compact, robust and non-corrosive aluminium body with high lumen output LEDs that enhances the safety and architectural design of step and entrance areas.(Make- Wipro, Model No. :LT51-750-XXX-57-XX, Crompton LSL-6-CDL or equivalent in Havells)

100

-

-

... More
450 Watt LED flood light IP66 luminaire with aluminum die-cast housing, toughened glass, and unique lens system, for enhanced illumination with inbuilt complete assembly LED driver having high efficacy(Make- Wipro, Model No. : LF20-622-060-57-G3)

65

-

-

... More
Supplying and erecting 12.5 m (clear height) motorized high-mast (Top -150mm, Bottom- 360mm) hot dipped galvanized material with average minimum thickness 65 micron, made from high tensile structure grade steel as per BSEN - 10025 S 355/E350 & 3mm thickness, with base plate 25 mm thick x OD 520 mm grade as per IS-2062, pole made in single section & submerge arc welded, with lowering & raising motorized unit, wire rope stainless steel 316 grade 2 nos., 7x19 construction 5mm, SG-DG U clamps, double drum with assembly 250 kg, 5x2.5 Sq.mm. flexible copper cable with lantern carriage assembly suitable for max. 12 nos. luminaires and its control gear box, lightning arrestor, arrangement for fixingaviation light, high-mast with serial number, factory inspection report/test report of high-mast should be provided as per specifications on provided foundation J type stud/bolts with necessary accessories complete as per specification no. OHPL/HM (excluding luminaries)

20

-

-

... More
Supplying and erecting 25 m (clear height) motorized high-mast (Top-200mm, Bottom- 560 mm) hot dipped galvanized material with average minimum thickness 65 micron, made from high tensile structure grade steel as per BSEN -10025 S 355/E350 & 3+4+5 mm thickness, with base plate 25 mm thick x OD 730 mm grade as per IS-2062, pole made in single section & submerge arc welded, with lowering & raising motorized unit, wire rope stainless steel - 316 grade 2 nos., 7x19 construction 6 mm, SG-DG U clamps, double drum winch assembly 600 kg, 5x2.5 sq.mm flexible copper cable with lantern carriage assembly suitable for max. 16 nos. luminaires and its control gear box, lightning arrestor, arrangement for fixing aviation light, high-mast with serial number, factory inspection report/test report of high-mast should be provided as per specifications on provided foundation J type stud/bolts with necessary accessories complete. specification no. OH-PL/HM (excluding luminaries)

4

-

-

... More
Supply and erecting 9m (clear height) Fixed type high-mast (Top-100mm, Bottom- 200mm) with hexagonal /round bracket and foundation bolts suitable for max. 4 nos. flood light fixtures on provided foundation as per specification no. OH-PL/OPL (excluding luminaires).

20

-

-

... More
Providing & erecting 3 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 130 mm A/F, top 70 mm A/F on provided foundation as per specification no. OH-PL/OPL

20

-

-

... More
Providing & erecting 6 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 130 mm A/F, top 70 mm A/F on provided foundation as per specification no. OH-PL/OPL

235

-

-

... More
Providing & erecting 9 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 130 mm A/F, top 70 mm A/F on provided foundation as per specification no. OH-PL/OPL

20

-

-

... More
Providing and erecting galvanised 1000mm single arm sword type bracket with FRP dome and ball as per specification no. OH-PL/PBKT

225

-

-

... More
Providing and erecting galvanised 1000mm double arm sword type bracket with FRP dome and ball as per specification no. OH-PL/PBKT

50

-

-

... More
Supplying and erecting outdoor stand mounted feeder pillar for high-mast of the same manufacturer with 32A TPN MCB incomer, 24hr astronomical time switch with minimum 5 years battery backup, IP 54 and IK10 protection, 25 A TP contactor for automatic switching of luminaires, 2 no. 9A contactors and raise/lower push button, and provision for termination of adequate size of incoming and outgoing cables complete erected in min. 14 SWG CRCA sheet box with supporting angles, self lock, gasket and slanting top erected on CC foundation complete

20

-

-

... More
Supplying and erecting outdoor stand mounted feeder pillar for high-mast of the same manufacturer with 63A TPN MCB incomer, 24hr astronomical time switch with minimum 5 years battery backup, IP 54 and IK10 protection, 45 A TP contactor for automatic switching of luminaires, 2 no. 9A contactors and raise/lower push button, and provision for termination of adequate size of incoming and outgoing cables complete erected in min. 14 SWG CRCA sheet box with supporting angles, self lock, gasket and slanting top erected on CC foundation complete

4

-

-

... More
Supplying and erecting integrated LED street light fitting 40 to 50W IP65 & IK08 class having single piece pressure die-cast aluminium housing, having system lumens output of Min. 4400 Lumens, min. efficacy of 110 lumen/W, CRI70, CCT upto 6500K,THD10%, p.f. 0.95, operating range of 140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, including driver complete with 3 Years warranty as per specification No FG-ODF/FLS2.

235

-

-

... More
Supplying and erecting integrated LED street light fitting 100-110W IP65 & IK08 class having single piece pressure die-cast aluminium housing, having system lumens output of Min. 11000 Lumens, min. efficacy of 110 lumen/W, CRI70, CCT upto 6500K, THD10%, p.f. 0.95, operating range of 140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, including driver complete with 3 Years warranty as per specification No FG-ODF/FLS2.

20

-

-

... More
Supplying and erecting integrated LED flood light fitting Max. 50W IP65 & IK07 class having pressure die-cast aluminium housing, having system lumens output of Min. 5000 Lumens, min. efficacy of 100 lumen/W, CRI70, CCT upto 6500K, THD10%, p.f. 0.90, operating range of 140-270V, inbuilt surge protection of 4 kV, Life class of 50,000 Hrs. at L70B50, including driver with U shaped bracket with 3 Years warranty as per specification No FG-ODF/FLS2.

100

-

-

... More
Supplying and erecting integrated LED flood light fitting Max. 70W IP65 & IK07 class having pressure die-cast aluminium housing, having system lumens output of Min. 8400 Lumens, min. efficacy of 120 lumen/W, CRI70, CCT upto 6500K, THD10%, p.f. 0.90, operating range of 140-270V, inbuilt surge protection of 4 kV, Life class of 50,000 Hrs. at L70B50, including driver with U shaped bracket with 3 Years warranty as per specification No FG-ODF/FLS2.

50

-

-

... More
Supplying and erecting integrated LED flood light fitting Max. 100W IP65 & IK07 class having pressure die-cast aluminium housing, having system lumens output of Min. 12000 Lumens, min. efficacy of 120 lumen/W, CRI70, CCT upto 6500K, THD10%, p.f. 0.90, operating range of 140-270V, inbuilt surge protection of 4 kV, Life class of 50,000 Hrs. at L70B50, including driver with U shaped bracket with 3 Years warranty as per specification No FG-ODF/FLS2.

10

-

-

... More
Supplying and erecting integrated LED flood light fitting Max. 195W IP65 & IK07 class having pressure die-cast aluminium housing, having system lumens output of Min. 23400 Lumens, min. efficacy of 120 lumen/W, CRI70, CCT upto 6500K, THD10%, p.f. 0.90, operating range of 140-270V, inbuilt surge protection of 4 kV, Life class of 50,000 Hrs. at L70B50, including driver with U shaped bracket with 3 Years warranty as per specification No FG-ODF/FLS2.

50

-

-

... More
Supplying and erecting integrated LED Bollard Cylindrical/Cubical shaped 500mm 8W IP65 & IK10 class having extrusion aluminium housing with polycarbonate diffuser, having system lumens output of Min. 800 Lumens, min. efficacy of 100 lumen/W, CRI80, CCT upto 6500K, THD10%, p.f. 0.90, operating range of 140-240V, inbuilt surge protection of 2 kV, Life class of 25,000 Hrs. at L50B50, including driver complete with 2 Year warranty as per specification No FG-ODF/FLS2.

300

-

-

... More
Supplying and erecting integrated LED Post Top 45W IP65 & IK10 class having die cast aluminium housing with UV protected polycarbonate diffuser, having system lumens output of Min.4500 Lumens, min. efficacy of 100 lumen/W, CRI80, CCT upto 6500K, THD10%, p.f. 0.90, operating range of 140-240V, inbuilt surge protection of 2 kV, Life class of 30,000 Hrs. at L50B50 , including driver complete with 2 Year warranty as per specification No FGODF/FLS2

150

-

-

... More
Supplying, erecting, testing and commissioning of diesel generating set with alternator of 125 kVA output continuous rating, 3 Phase, 415 V, 50c/s 0.8 p. f. A.C supply, a totally enclosed air cooled / liquid cooled multi-cylinder diesel engine developing suitable BHP at 1500 rpm with 10% overload for 1 hour in 12 hours, along with standard accessories, self-excited, self-regulated, screen protected alternator with static excitation system running at 1500 RPM as per IS 4722-2001 with voltage regulation +/- 5 %, with performance class G2 and maximum fuel consumption 34.40 Ltr/hr @75% loading. Both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on anti-vibrating pads with standard control panel comprising meters, switchgears, indicators connected with suitable wires/cables, the complete set enclosed in composite Acoustic enclosure as fully assembled integral unit made of 16 SWG CRCA Sheet, sound absorbing material to restrict sound level up to 75 dB(A) at 1.0 m, provided with first filling of oil, diesel not less than 300 Ltr etc. on provided M20 Grade CC Foundation as per specification no. GEN-DG

2

-

-

... More
Supplying, erecting, testing and commissioning of diesel generating set with alternator of 380/400 kVA output continuous rating, 3 Phase, 415 V, 50c/s 0.8 p. f. A.C supply, a totally enclosed air cooled / liquid cooled multi-cylinder diesel engine developing suitable BHP at 1500 rpm with 10% overload for 1 hour in 12 hours, along with standard accessories, self-excited, self-regulated, screen protected alternator with static excitation system running at 1500 RPM as per IS 4722-2001 with voltage regulation +/- 5 %, with performance class G2 and maximum fuel consumption 65.5 Ltr/hr @75% loading. Both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on anti-vibrating pads with standard control panel comprising meters, switchgears, indicators connected with suitable wires/cables, the complete set enclosed in composite Acoustic enclosure as fully assembled integral unit made of 16 SWG CRCA Sheet, sound absorbing material to restrict sound level up to 75 dB at 1.0 m, provided with first filling of oil, diesel not less than 450 Ltr etc. on provided M20 Grade CC Foundation and obtaining necessary approval from Electrical Inspector as per specification no. GEN-DG

1

-

-

... More
Supplying, erecting, testing and commissioning of diesel generating set with alternator of 500 kVA output continuous rating, 3 Phase, 415 V, 50c/s 0.8 p. f. A.C supply, a totally enclosed air cooled / liquid cooled multi-cylinder diesel engine developing suitable BHP at 1500 rpm with 10% overload for 1 hour in 12 hours, along with standard accessories, self-excited, self-regulated, screen protected alternator with static excitation system running at 1500 RPM as per IS 4722-2001 with voltage regulation +/- 5 %, with performance class G2 and maximum fuel consumption 81.90 Ltr/hr @75% loading. Both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on anti-vibrating pads with standard control panel comprising meters, switchgears, indicators connected with suitable wires/cables, the complete set enclosed in composite Acoustic enclosure as fully assembled integral unit made of 16 SWG CRCA Sheet, sound absorbing material to restrict sound level up to 75 dB at 1.0 m, provided with first filling of oil, diesel not less than 690 Ltr etc. on provided M20 Grade CC Foundation and obtaining necessary approval from Electrical Inspector as per specification no. GEN-DG

3

-

-

... More
Supplying, erecting, testing and commissioning of diesel generating set with alternator of 750 kVA output continuous rating, 3 Phase, 415 V, 50c/s 0.8 p. f. A.C supply, a totally enclosed air cooled / liquid cooled multi-cylinder diesel engine developing suitable BHP at 1500 rpm with 10% overload for 1 hour in 12 hours, along with standard accessories, self-excited, self-regulated, screen protected alternator with static excitation system running at 1500 RPM as per IS 4722-2001 with voltage regulation +/- 5 %, with performance class G2 and maximum fuel consumption 126.4 Ltr/hr @75% loading. Both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on anti-vibrating pads with standard control panel comprising meters, switchgears, indicators connected with suitable wires/cables, the complete set enclosed in composite acoustic enclosure as fully assembled integral unit made of 16 SWG CRCA sheet, sound absorbing material to restrict sound level up to 75 dB at 1.0 m, provided with first filling of oil, diesel not less than 990 Ltr etc. on provided M20 Grade CC Foundation and obtaining necessary approval from Electrical Inspector as per specification no. GEN-DG

2

-

-

... More
D.G Exhaust pipingSupply, laying and fixing of following sizes of MS Piping ("B" class) for Exhaust system as per IS: Including supply and providing of fittings, support channels, angles, plates, clams nut bolts, fastener, MS bends etc. cutting and shaping of shafts (if required) All the supports should be given as per the guidelines of the original manufacturer. complete in all respect and as directed by the Engineer-in-Charge. Exhaust system as per IS: 3589 and 1239 (Part-I) amended and revised to date including bends, structural supports, M.S. Channel, fasteners, Insert plate and all accessories as required at site & as per drawings. (The contractor shall submit back- pressure calculations in support of exhaust pipe size for each DG Set)125mm dia MS Pipe 4.85mm thickness

30

-

-

... More
150 mm dia MS pipe 4.85 mm thickness

45

-

-

... More
250 mm dia MS pipe 4.85mm thickness

30

-

-

... More
Providing and fixing following sizes (internal dia) externally pressurized expansion bellows rated for Min. 2 bar pressure or as required by the piping system and -20 to 550 Deg C Temperature. Bellows shall be made of SS 321 and flanges shall be made of Mild steel as per ASA# 150lbs. The expansion bellows shall provide axial movement upto 50 mm due to pipe expansion at Horizontal direction. Expansion bellows shall be provided with control rods/ guides and integrated lining to reduce turbulence and ensure proper internal alignment.125 mm dia

2

-

-

... More
150 mm dia

3

-

-

... More
250 mm dia

2

-

-

... More
Supply and fixing of DG Exhaust pipe insulation with 50mm thick LRB Rockwool (of 100 kgs. Per cubic meter density) over the exhaust pipes of including cladding with aluminium sheet of 26 SWG and covering from outside complete as required suitable for DG exhaust pipe temp. upto 450 deg C. (Surface temperature of exhaust pipe shall be maximum ambient + 15 deg C but not exceeding more than 60 deg C) as per specifications (for Vertical & horizontal run of pipes).

35

-

-

... More
Oil Piping for DG sets:- Providing & Fixing MS "C" class interconnecting fuel piping between the tanks, main piping from outside for tanks filling complete with bends and shut off valves as required from day oil tank to engines, with all standard accessories, and fuel piping between fuel tank and diesel engine with PVC braided pipes of suitable dia: 25mm dia pipe MS ERW

100

-

-

... More
25mm dia Gate valve flanged type

10

-

-

... More
Manual fuel filling arrangement including Hand operated Gear pump, barrel, suitable flexible pipe etc shall be provided .

2

-

-

... More
Fuel TankDaily service fuel tank built in the acoustic enclosure of 990 liters capacity fabricated out of 3 mm thick M.S. sheet complete with all standard accessories shall include 450 mm ID manhole cover, level indicator with duly calibrated scale and flanged connection for inlet, outlet, overflow drain and probe provision for level controller & breather as required as per specifications.

6

-

-

... More
EARTHING (EA) - FOR SUBSTATIONSupplying, installation and testing of maintenance free earthing comprising of Electrode of 17.2 mm diameter Low Carbon Steel with 250 micron molecular copper bonded earthing rod of Length 3m along with 25 kg Carbon based environment friendly back fill ground enhancing compound required to fill up the excavated earth with required quantity complete, and recording the results Specification no. EA-MOBI

38

-

-

... More
Providing earthing with copper earth plate size 60 x 60 x 0.315 cm with funnel with a wire mesh for watering and brick masonry block C.l. cover with minimum 25 kg Carbon based environment friendly back fill Ground Enhancing compound complete with all materials, testing & recording the results as per specification no ESE -LA

22

-

-

... More
Supplying and erecting GI wire of high purity of required sizes used for earthing or any other purposes on wall with necessary G. I. Clamps fixed on wall/cable/ conduit with screws complete.

200

-

-

... More
Supplying and erecting copper strip of required size used for earthing on wall and/or any other purpose with necessary copper clamps fixed on wall painted with insulating and non-corrosive bond with required joints As per specification no. EA-EP.

400

-

-

... More
Supplying and erecting GI strip of required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with insulating and non-corrosive bond with required joints As per specification no. EA-EP.

1000

-

-

... More
Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint with joints required. As per specification no EA-EP.

50

-

-

... More
Supplying and erecting GI wire of high purity of required sizes used for earthing or any other purposes on wall with necessary G. I. Clamps fixed on wall/cable/conduit with screws complete.

1000

-

-

... More
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 2 core 10 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL

9000

-

-

... More
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 10 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL

2500

-

-

... More
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 16 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL

2000

-

-

... More
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 25 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL

300

-

-

... More
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 35 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL

100

-

-

... More
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 50 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL

100

-

-

... More
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 70 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL

350

-

-

... More
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 95 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL

100

-

-

... More
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 120 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL

100

-

-

... More
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 150 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL

800

-

-

... More
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 185 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL

500

-

-

... More
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 240 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL

300

-

-

... More
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 300 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL

8760

-

-

... More
Supplying, erecting & terminating XLPE insulated unarmoured cable 1100 V. 1 core 25 sq. mm. copper conductor complete erected with provided lugs, laid in provided control panel /distribution boards / pipe as per specification no. CBLT/CU

100

-

-

... More
Supplying, erecting & terminating XLPE insulated unarmoured cable 1100 V. 1 core 35 sq. mm. copper conductor complete erected with provided lugs, laid in provided control panel /distribution boards / pipe as per specification no. CBLT/CU

100

-

-

... More
Supplying, erecting & terminating XLPE insulated unarmoured cable 1100 V. 1 core 50 sq. mm. copper conductor complete erected with provided lugs, laid in provided control panel /distribution boards / pipe as per specification no. CBLT/CU

100

-

-

... More
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3 core 2.5 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU

1000

-

-

... More
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3 core 4 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU

500

-

-

... More
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3 core 10 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU

100

-

-

... More
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 6 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU

100

-

-

... More
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 10 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU

100

-

-

... More
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 16 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU

100

-

-

... More
Supplying , erecting & terminating XLPE insulated, galvanised steel formed wire armoured (strip) cable 11 kV(E), 3 x 240 sq. mm. aluminium conductor laid in provided trench / pipe as per specification no. CB-HT

700

-

-

... More
Providing & erecting epoxy outdoor / indoor end termination kit for LT XLPE armoured cable 2.5 to 16 sq mm., with necessary material as per specification No. CB-JT/LT

10

-

-

... More
Providing & erecting epoxy outdoor / indoor end termination kit for LT XLPE armoured cable 25 to 50 sq mm, with necessary material as per specification No. CB-JT/LT

10

-

-

... More
Providing & erecting epoxy outdoor / indoor end termination kit for LT XLPE armoured cable 70 to 120 sq mm, with necessary material as per specification No. CB-JT/LT

10

-

-

... More
Providing & erecting epoxy outdoor / indoor end termination kit for LT XLPE armoured cable 150 to 185 sq mm, with necessary material as per specification No. CB-JT/LT

10

-

-

... More
Providing & erecting epoxy outdoor / indoor end termination kit for LT XLPE armoured cable 240 to 300 sq mm, with necessary material as per specification No. CB-JT/LT

10

-

-

... More
Cable Joints & End Termination Kits (HT Cables) (CB-JT/HT)Providing and erecting Heat shrinkable indoor termination kit for 11 kV ( E ) XLPE HT cable 3x240 to 300 sq. mm. with necessary material as per specification no. CB-JT/HT

10

-

-

... More
Supplying & laying (including excavation) reinforced cement concrete pipe of IS 458:2003 NP-2 class of 150 mm internal diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete.

250

-

-

... More
Supplying & laying (including excavation) reinforced cement concrete pipe of IS 458:2003 NP-2 class of 250 mm internal diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete.

100

-

-

... More
Supplying and laying (including excavation of suitable width & depth up to 90 cm) 75 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete.

100

-

-

... More
Supplying and laying (including excavation of suitable width & depth up to 90 cm) 160 mm outside dia, double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete.

100

-

-

... More
Supplying, laying, tesing & commissioning of following 1100 volt grade XLPE insulated PVC sheathed Aluminium/Copper conductor armoured/Unarmored cables as per specification in cable trays / ducts clamped to wall with suitable clamps including, saddles fixing bolts, connecting testing and commissioning complete in all respect as required as per site conditions.12 core 2.5 sq.mm shielded Cu. Cable

100

-

-

... More
4 core 2.5 sq.mm Cu arm. Cable

150

-

-

... More
2 core 4 sq.mm Cu arm. Cable

50

-

-

... More
12 core 1.5 sq.mm shielded Cu. Cable

100

-

-

... More
Supplying and making Cable end termination of the following XLPE insulated PVC sheathed copper conductor armoured cables of 1100 volt grade including supplying and fixing of Copper crimping lugs, double compression glands with earthing testing and commissioning complete in all respect as required as per site conditions.4 core 2.5 sq.mm Cu arm.

20

-

-

... More
12 core 2.5 sq.mm Cu arm.

8

-

-

... More
2 core 4 sq.mm Cu arm.

10

-

-

... More
Providing & erecting hot dipped galvanised ladder type cable tray manufactured from 16 SWG (1.6 mm thick) GI sheet of 150 mm width & 75 mm height complete with necessary coupler plates & hardware.

100

-

-

... More
Providing & erecting hot dipped galvanised ladder type cable tray manufactured from 16 SWG (1.6 mm thick) GI sheet of 300 mm width & 75 mm height complete with necessary coupler plates & hardware.

100

-

-

... More
Providing & erecting hot dipped galvanised ladder type cable tray manufactured from 16 SWG (1.6 mm thick) GI sheet of 500 mm width & 75 mm height complete with necessary coupler plates & hardware.

50

-

-

... More
Providing & erecting hot dipped galvanised cover suitable for perforated type Cable tray manufactured from 18 SWG (1.2 mm thick) GI sheet of 150 mm width & 20 mm height complete with necessary hardware.

300

-

-

... More
Providing & erecting hot dipped galvanised cover suitable for perforated type Cable tray manufactured from 18 SWG (1.2 mm thick) GI sheet of 300 mm width & 20 mm height complete with necessary hardware.

200

-

-

... More
Providing & erecting hot dipped galvanised cover suitable for perforated type Cable tray manufactured from 18 SWG (1.2 mm thick) GI sheet of 500 mm width & 20 mm height complete with necessary hardware.

100

-

-

... More
SWITCHGEARS (SW) (For High Side)Supplying, erecting & marking SPMCB 6A to 32A, C-series with rated short -circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB

78

-

-

... More
Supplying, erecting & marking DPMCB 40A to 63A, C-series with rated short -circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB

10

-

-

... More
Supplying, erecting & marking TPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB

360

-

-

... More
Supplying, erecting & marking FPMCB 40A to 63A, with rated short-circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB

50

-

-

... More
Supplying & erecting triple pole and neutral distribution board (TPNDB), SPMCB of 4 ways/phase (12 poles), with door, 1.2mm thickness, surface/flush mounted, IP 43 protection on iron/GI frame (horizontal busbar type) as per specification no. SW-SWR/MCBDB

1

-

-

... More
Supplying & erecting triple pole and neutral distribution board (TPNDB), SPMCB of 8 ways / phase (24 poles), with door, 1.2mm thickness surface/flush mounted, IP 43 Protection on iron/GI frame (horizontal busbar type) as per specification no. SW-SWR/MCBDB

1

-

-

... More
Supplying & erecting triple pole and neutral distribution board (TPNDB), SPMCB of 12 ways /phase (36 poles), with door, 1.2mm thickness surface/flush mounted, IP 43 Protection on iron/GI frame (horizontal busbar type) as per specification no. SW-SWR/MCBDB

1

-

-

... More
Supplying and erecting single pole and neutral distribution board (SPNDB), with 2 ways for incoming and 10 ways (10 poles) for outgoing SP MCBs, with door, 1.2mm thickness surface / flush mounted, IP 43 Protection on iron /GI frame as per specification no. SW-SWR/MCBDB

1

-

-

... More
Supplying, erecting & commissioning 2 pole RCCB 40A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB capacity of 40A complete as per specification no. SW RCCB/ RCCB

10

-

-

... More
Supplying & erecting triple pole and neutral distribution board (TPNDB), 3 pole/ 4 pole MCCB as incomer & outgoing SP MCB (12 poles) or TP MCB of 4 ways (12 poles), with door, 1.2mm thickness, surface/flush mounted, on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB1

20

-

-

... More
Supplying & erecting triple pole and neutral distribution board (TPNDB), 3 pole/4 pole MCCB as incomer & outgoing SP MCB (24 poles) or TP MCB of 8 ways (24 poles), with door, 1.2mm thickness, surface/flush mounted, on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB1

20

-

-

... More
Supplying & erecting triple pole and neutral distribution board (TPNDB), 3 pole/4 pole MCCB as incomer & outgoing SP MCB (36 poles) or TP MCB of 12 ways (36 poles), with door, 1.2mm thickness, surface/flush mounted, on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB1

10

-

-

... More
ROOFTOP ON GRID SOLAR SYSTEMS (ESD-RT-ONG)Supplying, installing, testing and commissioning of 25 kWp ON-GRID Solar PV System / Plant consisting Solar PV Poly Crystalline Panel (335 Wp X 75 Nos.) and Solar ON-GRID Inverter of similar capacity (THD3%) with interconnecting wires / cables up to solar ON GRID inverter, proper base plate, canopy box to house Inverter and necessary accessories i.e. ACDB/ DCDB , MCB etc. wiring up to solar Inverter in casing and capping, display board, sign board, two distinct earthing, lightning arrester, liaisoning charges, remote monitoring system with maintaining card / chip for 5 years including net charges for RMS System, complete up to net meter installation and export to the grid with 5 year ON-SITE warranty and fully comprehensive maintenance contract as per Specification no. ESD-RT-ONG.

6

-

-

... More
Supplying and erecting HMS PVC conduit FRLS grade 20 mm dia. With necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC.

2680

-

-

... More
Supplying and laying HMS PVC conduit FRLS grade 20 mm dia. With necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC.

7590

-

-

... More
Supplying and erecting HMS PVC conduit FRLS grade 25 mm dia. With necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC.

22150

-

-

... More
Supplying and laying HMS PVC conduit FRLS grade 25 mm dia with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC.

39283

-

-

... More
Supplying and erecting HMS PVC conduit FRLS grade 32 mm dia. With necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC.

6670

-

-

... More
Supplying and laying HMS PVC conduit FRLS grade 32mm dia. With necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC.

25930

-

-

... More
Supplying and erecting mains with 3x4 sq.mm FRLSH copper PVC insulatedwire laid in provided conduit/trunking/inside pole/Bus bars or any other placesas per specification No: WG-MA/BW

48225

-

-

... More
Supplying and erecting mains with 3x6 sq.mm FRLSH copper PVC insulatedwire laid in provided conduit/trunking/inside pole/Bus bars or any other placesas per specification No: WG-MA/BW

19119

-

-

... More
Supplying and erecting mains with 3x10 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW

10326

-

-

... More
Supplying and erecting mains with 3x16 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW

3400

-

-

... More
Supplying and erecting modular type 3 pin 6A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete.

3728

-

-

... More
Supplying and erecting modular type 3 pin 6 / 16A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete.

2376

-

-

... More
Supplying and erecting modular type T.V. socket single outlet, duly erected on provided plate and box with wiring connections complete.

75

-

-

... More
Supplying and erecting modular type telephone socket one gang with safety shutter, duly erected on provided plate and box with wiring connections complete.

527

-

-

... More
Supplying and erecting modular type computer Jack RJ45 with safety shutter, duly erected on provided plate and box with wiring connections complete.

568

-

-

... More
Supplying and erecting modular type blanking plate one module, duly erected on provided plate & box.

550

-

-

... More
Point wiring for light/bell concealed type in min 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WGPW/CW

6103

-

-

... More
Secondary point wiring for additional light/ bell point, concealed type in min 20 mm FRLS grade PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires with required accessories as per specification No: WG-PW/CW

3843

-

-

... More
Point wiring for ceiling fan in 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm (2+1E) FRLSH grade copper wire, modular type switch, earthing and required accessories as per specification No: WG-PW/SW

2377

-

-

... More
Point wiring for independent plug, concealed type in min 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No WG-PW/SW

1922

-

-

... More
Wiring for plug on board with Switch socket surface/concealed type, copper wiring and earthing and with modular accessories as per specification No: WGPW/CW

1808

-

-

... More
Supplying & erecting 2 pair telephone copper cable 0.5 mm dia. with high density polyethylene insulation, polyester taped, Nylon Rip Cord & grey colour sheathed with FR PVC, conforming to ITD specification S/WS 113C laid in provided PVC casing capping/conduit as per specification No. WG-TW

25460

-

-

... More
Supplying & erecting 20 pair, 0.5mm dia, jelly filled unarmoured telephone copper cable with poly-al laminate moisture barrier, laid in provided PVC casing capping/conduit as per specification No. WG-TW

1200

-

-

... More
Supplying & erecting 10 pair, 0.5mm dia, jelly filled unarmoured telephone copper cable with poly-al laminate moisture barrier, laid in provided PVC casing capping/conduit as per specification No. WG-TW

700

-

-

... More
Supplying & erecting 50 pair, 0.5mm dia, jelly filled unarmoured telephone copper cable with poly-al laminate moisture barrier, laid in provided PVC casing capping/conduit as per specification No. WG-TW

1110

-

-

... More
Supplying & erecting co-axial copper cable low voltage grade tri-shielded RG 6 as per specification No. WG-TW

3750

-

-

... More
Supplying and installing enhanced cat-6 LSZH cable with 4-connector channel Performance test report as per ANSI/TIA-568.2-D suitable for networking complete as per specification.

55110

-

-

... More
Supplying, erecting & commissioning 50 pairs FR junction box with moulded plastic enclosure as per specification no. WG-TW

34

-

-

... More
Supplying, erecting & commissioning 20 pairs FR junction box with moulded plastic enclosure as per specification no. WG-TW

18

-

-

... More
Supplying, erecting & commissioning 10 pairs FR junction box with moulded plastic enclosure as per specification no. WG-TW

7

-

-

... More
Supplying, fixing, and configuring 8-ports managed gigabit, Layer-2 switch, 10/100/1000 base-T, POE smart switch plus 2 SFP erected in provided rack complete.

2

-

-

... More
Supplying, fixing, and configuring 24 ports, POE switch in provided rack as per specification No. WG-NWC/ENS

102

-

-

... More
Supplying and fixing 12U wall mount rack (Dimension-DxWxH – 500x600x635 mm) as per specification No. WG-NAS/RAK

51

-

-

... More
Supplying and fixing 6U wall mount rack (Dimension-DxWxH – 500x600x367 mm) as per specification No. WG-NAS/RAK

1

-

-

... More
Supplying and erecting LED Panel Light(600mm X 600mm) Max. 30 W having CRCA powder coated housing, polystyrene diffuser having system lumens output of Min. 3600 Lumens, min. efficacy of 120 lumen/W, CRI80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD10%, p.f. 0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50 including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty.

3152

-

-

... More
Supplying and erecting LED square / circular Max. 18 W down lighter/ Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 2000 Lumens, min. efficacy of 110 lumen/W, CRI80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD10%, p.f. 0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty.

2693

-

-

... More
Supplying and erecting LED square / circular Max. 11 W down lighter/Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 1200 Lumens, min. efficacy of 110 lumen/W, CRI80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD10%, p.f. 0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty.

374

-

-

... More
Supplying and erecting bulk head LED fitting max. 10W with high transitivity diffuser with system lumens output of min. 1100 lumens, min. efficacy of 110 lumen/W, CRI80, CCT upto 6500K, Beam Angle of 120 deg., THD10%, p.f. 0.95, operating range of 140-260V, in built surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, IP66, IK09 rated on provided PVC Block / wooden board with 3 years warranty.

203

-

-

... More
Supplying and erecting anodized aluminium corridor / passage / mirror light LED fitting (2 feet) Max. 12W with high transitivity diffuser with min. system lumens output of 1200 lumens, min. efficacy of 100 lumen/W, CRI80, CCT upto 6000K, Beam Angle of 110 deg., Ripple5%, THD10%, p.f. 0.95, operating range of 200-270V, surge protection of 2 kV, Life class of 50,000 Hrs. at L70B50, including driver with end caps on provided PVC Block / wooden board with 3 years warranty.

757

-

-

... More
Supplying and erecting anodized aluminium corridor / passage light LED fitting (4 feet) Max. 22W with high transitivity diffuser with system lumens output of Min.2200 lumens , min. efficacy of 100 lumen/W, CRI80, CCT upto 6000K, Beam Angle of 110 deg., Ripple5%, THD10%, p.f. 0.95, operating range of 200-270V, surge protection of 2 kV, Life class of 50,000 Hrs. at L70B50, including driver, with end caps on provided PVC Block / wooden board with 3 years warranty.

1532

-

-

... More
Supplying and erecting Energy Saving BLDC Ceiling fan 230 V A.C. 50 cycles 1200 mm, max. energy consumption of 28W having service ratio (CMM/W) of Min. 8 , PF0.9, THD10% with IR remote control/compatible speed regulator, Temperature Rise of Max. 40 deg. C, having external mounted control PCB completely erected in position as per specification no. FG-FN/CF

2450

-

-

... More
Supplying and erecting fresh air cum exhaust fan of light duty 250 V A.C. 50 cycles 300mm. 1400 RPM rust proof body & blades, wire mesh, duly erected, complete.

362

-

-

... More
Supplying and erecting regular/ standard model ceiling fan of 600mm. Sweep complete erected in position as per specification no. FG-FN/CF

24

-

-

... More
SUPPLY & INSTALLATION OF LIGHT FIXTURES40 W ceiling suspended Unidirectional LED Linear lighting solution with extruded aluminium housing and high transmissivity HET/UGR diffuser suitable for indoor application.(Make- Wipro: LM34-501-XXX57WG2L or equivalent in Crompton/ Havells)

91

-

-

... More
30 W ceiling suspended Unidirectional LED Linear lighting solution with extruded aluminium housing and high transmissivity HET/UGR diffuser suitable for indoor application.(Make- Wipro: Stylus MPO | LM43 or equivalent in Crompton/ Havells)

91

-

-

... More
20W LED recessed COB light (size 110mm DIA) 4000k (Make- Wipro, Model: Gimball- LD56-251-060-40-XX or equivalent in Crompton/ Havells)

303

-

-

... More
20W LED recessed COB light (size 120x120mm) 4000k (Make- Wipro, Model: Gimball- LD58-251-24-57-WG1 or equivalent in Crompton/ Havells)

219

-

-

... More
40W LED recessed COB light (size 230x120mm) 4000k (Make- Wipro, Model: Gimball- LD58-521-060-40 or equivalent in Crompton/ Havells)

137

-

-

... More
12 Watt Downlight fixture having low glare illumination, suitable for indoor application(Make- Wipro, Model No. :Fokus Surface (Square) LD34-151-xxx-40-SM or equivalent in Crompton/ Havells)

137

-

-

... More
18 Watt Downlight fixture having low glare illumination, suitable for indoor application(Make- Wipro, Model No. :Fokus Surface (Square) LD34-251-xxx-40-SM or equivalent in Crompton/ Havells)

140

-

-

... More
Recess mounted adjustable LED COB downlighter (track light) with high efficacy. Housing made of extruded aluminium Track Light(Make- Wipro, Model No. LD54-251-60-57-WG1 or equivalent in Crompton/ Havells)

197

-

-

... More
1 Mtr. length Single phase track suitable to mount track light

31

-

-

... More
2 Mtr. length Single phase track suitable to mount track light

31

-

-

... More
Ceiling suspended/surface mounted, unique, tapered profile product; high on aesthetics and performance.Housing with micro-texture powder coating(Make- Wipro, Model No. LD99-281-XXX57SMWH or equivalent in Crompton/ Havells)

58

-

-

... More
20 W surface mounted 4 feet LED light Fixture (6500K) with aluminium base suitable for indoor application.(Make- Wipro: LL24R-251-XX-57-XX, Crompton: LCTL -18-CDL, Havells: LUMILINEBS18W LED865SPCWH or equivalent in Crompton)

73

-

-

... More
8 Watt Up Lighters, polyester coated aluminium, suitable for housed in ground/ bushlight.(Make- Wipro, Model No. :Gardenia LF05-600-036-27-XX or equivalent in Crompton/ Havells)

124

-

-

... More
Ceiling suspended/surface mounted, unique, tapered profile product; high on aesthetics and performance.Housing with micro-texture powder coating(Make- Wipro, Model No. LD99-151-XXX57SMWH or equivalent in Crompton/ Havells)

46

-

-

... More
Supply and erection of 60W Decorative wall bracket light fixtre .(Make- Decon, Model No. :05AAM or equivalent in Crompton/ Havells)

96

-

-

... More
Online Uninterruptible Power Supply (UPS) (AP-UPS)Supplying, erecting, testing and commissioning of 20kVA capacity online pure sine wave, with backup time of 0.5 hrs. PWM & IGBT based UPS with 0.9 to unity output pf, 3 phase input and 3 phase output complete with all protections as per specification no. AP-UPS

20

-

-

... More
Supplying, installing, testing and commissioning of single phase, 230V, 50 Hz,2500 VA digital pure sine wave inverter with backup time of 2 hrs. based on Insulated Gate Bipolar Transistor (IGBT) technology complete as per specification no. AP-INV

13

-

-

... More
LT - MCBs/ MCB Change Over Switch (SW-MCB)Supplying, erecting & marking SPMCB 6A to 32A, C-series with rated short -circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB

8336

-

-

... More
Supplying, erecting & marking DPMCB 6A to 32A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB

52

-

-

... More
Supplying, erecting & marking TPMCB 6A to 32A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB

6

-

-

... More
Supplying, erecting & marking FPMCB 6A to 32A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB

196

-

-

... More
Supplying, erecting & marking FPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB

186

-

-

... More
Providing & erecting 3 Pole MCCB, 415 V, 100A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB

1

-

-

... More
Supplying & erecting triple pole and neutral distribution board (TPNDB), SPMCB of 8 ways / phase (24 poles), with door, 1.2mm thickness surface/flush mounted, IP 43 Protection on iron/GI frame (horizontal busbar type) as per specification no. SW-SWR/MCBDB

289

-

-

... More
Supplying & erecting triple pole and neutral distribution board (TPNDB), SPMCB of 12 ways /phase (36 poles), with door, 1.2mm thickness surface/flush mounted, IP 43 Protection on iron/GI frame (horizontal busbar type) as per specification no. SW-SWR/MCBDB

137

-

-

... More
Supplying and erecting single pole and neutral distribution board (SPNDB), with 2 ways for incoming and 6 ways (6 poles) for outgoing SP MCBs, with door, 1.2mm thickness surface / flush mounted, IP 43 Protection on iron / GI frame as per specification no. SW-SWR/MCBDB

1

-

-

... More
Supplying and erecting single pole and neutral distribution board (SPNDB), with 2 ways for incoming and 10 ways (10 poles) for outgoing SP MCBs, with door, 1.2mm thickness surface / flush mounted, IP 43 Protection on iron / GI frame as per specification no. SW-SWR/MCBDB

77

-

-

... More
Supplying, erecting & commissioning 2 pole RCCB 16/25A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB

573

-

-

... More
Supplying, erecting & commissioning 2 pole RCCB 40A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB

364

-

-

... More
Supplying, erecting & commissioning 2 pole RCCB 63A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB

111

-

-

... More
Supplying & erecting triple pole and neutral distribution board (TPNDB), 3 pole/ 4 pole MCCB as incomer & outgoing SP MCB (12 poles) or TP MCB of 4 ways (12 poles), with door, 1.2mm thickness, surface/flush mounted, on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB1

9

-

-

... More
Supplying & erecting triple pole and neutral distribution board (TPNDB), 3 pole/4 pole MCCB as incomer & outgoing SP MCB (24 poles) or TP MCB of 8 ways (24 poles), with door, 1.2mm thickness, surface/flush mounted, on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB1

14

-

-

... More
Supplying & erecting triple pole and neutral distribution board (TPNDB), 3 pole/4 pole MCCB as incomer & outgoing SP MCB (36 poles) or TP MCB of 12 ways (36 poles), with door, 1.2mm thickness, surface/flush mounted, on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB1

4

-

-

... More
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 16 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL

2500

-

-

... More
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 25 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL

1500

-

-

... More
Supplying, erecting & terminating XLPE insulated unarmoured cable 1100 V. 1 core 25 sq. mm. copper conductor complete erected with provided lugs, laid in provided control panel /distribution boards / pipe as per specification no. CBLT/CU

600

-

-

... More
FIRE FIGHTING & FIRE ALARM SYSTEM Supplying, installation, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the 4 loop capacity and capable of supporting upto 250 devices and detectors per loop, with on-board LCD display with min 16 lines of text, operating at 230 V 50 HZ - AC with inbuilt Battery Backup of a minimum 24 hours in normal condition and 30 min in alarm condition, suitable provision for network connectivity, interfacing with third party equipment via a MODBUS/ OPC/ L-ON interface etc. conforming to IS 15908:2021, ,IS 2189: 2008, EN 54 & VDS / FM/ UL 864 (10th edition) with 3 years replacement warranty FF-AFAS/CP.

11

-

-

... More
Supplying, installing, testing and commissioning of addressable optical smoke detector, single/twin LED’s with 360 degree view, suitable for low voltage 15 to 32 V DC two wires supply, in-built locking mechanism to check the removal and pilferage of the detector, in built isolation mode, start up current 300µA and alarm condition current shall be maximum 6.5 mA, operating temperature 0°C to 50°C, humidity 0-95% RH, IP 41, conforming to IS 2189: 2008, 11360_1985_Reff 2020 EN 54 or UL Approved with 3 years equipment replacement warranty FF AFAS/SD

1620

-

-

... More
Supplying, installing, testing and commissioning of intelligent addressable thermal/heat detector with rate of rise cum fixed temperature thermistor complete with base as required, suitable for temperature variations from -20°C to 38°C for fixed-heat and rate-of-rise type detectors and 0°C to 66°C for high heat type detectors, in built isolation mode, suitable for offices/ceiling cable trenches/less ventilation area's etc. with 3 years equipment replacement warranty IS : 2175 - 1988 reaffirmed 2000, IS 15908:2021 standards FF-AFAS/SD.

60

-

-

... More
Supplying, installing, testing and commissioning of addressable manual call points ( break glass type/pull station type), made of addressable break glass plastic square in shape surface/flush mounted with "Break Glass" massage embedded on the glass, complete erected with mounting base and required accessories conforming to EN 54 or UL listed with 3 years equipment replacement warranty FF-AFAS/MCP

198

-

-

... More
Supplying, installing, testing and commissioning of addressable fire control/relay module complete as required, with 3 years equipment replacement warranty conforming to IS 5051Part 2 (Sec 1 to 3) : 1982 reed relays, EN 54 or UL Listed FF-AFAS/CRM

210

-

-

... More
Supplying, installing, testing and commissioning of addressable fire monitor module complete as required. EN 54 or UL Listed with 3 years equipment replacement warranty conforming to IS 5051Part 2 (Sec 1 to 3) : 1982 Reed relays FF-AFAS/MM

90

-

-

... More
Supplying, installing, testing and commissioning of addressable fire isolator module complete as required. EN 54 /FM or UL Listed with 3 years equipment replacement warranty conforming to IS 5051 Part 2 (Sec 1 to 3) : 1982 Reed relays FF-AFAS/ISM

160

-

-

... More
Supplying, installing, testing and commissioning of addressable horn cum strobe sound/ hooter, output frequency 500 to 1000 Hz with dB as per Chart given in IS 15908:2021, with flashing at 1 Hz over the strobe’s entire operating voltage range EN 54, conforming to IS 2189: 2008, IS 15908:2021 standards with 3 years equipment replacement warranty FF-AFAS/SSH.

230

-

-

... More
Supplying, installing, testing and commissioning FR, XLPE armoured cable 2 core 1.5 sq.mm. copper conductor complete erected on wall/ ceiling complete as per specification no. CB-LT/CU

28170

-

-

... More
PA System (FF-PAS)Supplying, erecting, testing and commissioning 120 W amplifier suitable to operate on 230 Volts A.C. / 12 Volts D.C. supply complete as per specification no. FF-PA/AFR

32

-

-

... More
Supplying, erecting, testing and commissioning 15 to 30 Watts sound column or ceiling mounted complete as per specification no. FF-PA/SOC

144

-

-

... More
Supplying, erecting, testing and commissioning of 1.0 sq. mm speaker wire complete.

29000

-

-

... More
Supplying, installing, testing and commissioning of 2 Zones Microprocessor based conventional fire alarm control panel (FACP) with standard accessories , 16x2 Character LCD Display, provision for zone wise contact and beep sound alarm, suitable to operate on 120-220 V AC, 0 - 49 Deg C, 93 ± 2 Percentage RH (non- condensing) at 32 ± 2 Deg C complete as per specification no. FF-FAAS/FACP

9

-

-

... More
Supplying, erecting testing and commissioning optical type smoke detector on suitable back box with necessary connections complete as per specification no. FF-FAS/SD

55

-

-

... More
Supplying, erecting testing and commissioning manual call point (Pill box) with break glass, push button (resettable type) in metal enclosure complete as per specification no. FF-FAAS/MCP

51

-

-

... More
Supplying, erecting testing and commissioning multi sensor heat detector with smoke and heat combination (RoR + fix temperature) with base on back box, necessary connections complete as per specification no. FF-FAS/HD

3

-

-

... More
Supplying, erecting, testing and commissioning hooters having high (100dB @ 1m) and low (94dB @ 1m) volume setting, group addressing facility allowing multiple sounders to be activated with CRCA enclosure complete as per specification no. FF-FAAS/HTR

51

-

-

... More
Supplying, installing, testing and commissioning FR, XLPE armoured cable 2 core 1.5 sq.mm. copper conductor complete erected on wall/ ceiling complete as per specification no. CB-LT/CU

1900

-

-

... More
PA SystemSupply,Installation,Testing & Commissioning of 2W Multi-Tap (0.25W; 0.5W; 1W; 2W), Ceiling Mount Speakers. The speakers shall be of same make as that of the Control Panel & Amplifiers. They shall be compatible with supplied Amplifiers and shall work on 70.7Vrms. UL Listed

456

-

-

... More
Supplying and drawing recessed/surface MS conduiting system including cost of providing G.I, saddles etc for surface conduiting and/or cost of cutting and filling chases for recessed conduiting complete with all accessories as per specifications, as required and as below.20 mm

1600

-

-

... More
25 mm

2400

-

-

... More
32 mm

800

-

-

... More
Supplying, installation and testing of maintenance free earthing comprising of Electrode of 17.2 mm diameter Low Carbon Steel with 250 micron molecular copper bonded earthing rod of Length 3m along with 25 kg Carbon based environment friendly back fill ground enhancing compound required to fill up the excavated earth with required quantity complete, and recording the results Specification no. EA-MOBI

112

-

-

... More
Supplying and erecting GI wire of high purity of required sizes used for earthing or any other purposes on wall with necessary G. I. Clamps fixed on wall/cable/ conduit with screws complete.

548

-

-

... More
Supply, installation, testing & commissioning of 1/3" CMOS IP IR Outdoor Bullet Cameras, up to 4 Megapixel Resolution (1280 x 1024), Focal (Zoom Ratio) 2.8 ~ 12mm (4.3x) varifocal, 25 FPS, IR viewable length: -20 Meters, Power over Ethernet (POE), 25fps @ all resolutions (H.264), Color: 0.04 Lux @ F1.4 (Color), 0 Lux @ F1.4 (B/W: IR LED on), DWDR, AGC, BLC, digital zoom, motion detection, tempering, IP 66, IK10, ONVIF, UL Listed.

22

-

-

... More
Supply, installation, testing & commissioning of 1/3" CMOS IP IR Indoor Varifocal Dome Cameras, up to 3 Megapixel Resolution), Auto Focus Varifocal 2.8-12 mm Megapixel Lens, 25 FPS, IR viewable length 15m, Power over Ethernet (POE), Color: 0.04 Lux (1/30sec, F1.4), 0.001 Lux (2sec, F1.4), B/W: 0 Lux (IR LED on) DWDR, AGC, BLC, digital zoom, motion detection, tempering, IP 66, IK 10 ONVIF, UL Listed.

633

-

-

... More
Supply, installation, testing & Commissioning of Open Platform NVR Networkable / Standalone (24 IP licenses), 8/ 12 bay ( with or without extension modules), with fully loaded 12 TB storage and free Client (Client Software), (RAID 0,1, 5 ), ONVIF Platform, 320 mbps(minimum), motion based recording, Intelligent Search, ONVIF complied, Including 24 camera license and 1 HDMI / 1 VGA output for connecting Monitors and USB mouse.

23

-

-

... More
Supply, installation, testing & Commissioning of Open Platform NVR Networkable / Standalone (65 IP licenses), 8/ 12 bay ( with or without extension modules), with fully loaded 24 TB storage and free Client (Client Software), (RAID 0,1, 5 ), ONVIF Platform, 320 mbps(minimum), motion based recording, Intelligent Search, ONVIF complied, Including 24 camera license and 1 HDMI / 1 VGA output for connecting Monitors and USB mouse.

3

-

-

... More
MAIN DISTRIBUTION BOARDSSupply, installation, testing and commissioning of Main Distribution Board with cubicle type totally enclosed free standing type, duly compartmentalised, dust free, damp and vermin proof fabricated From 2mm thick CRCA sheet steel duly powder coated painted, internally wired, interconnection with aluminium links, busbar chamber and having following incoming & outgoing moulded case circuit breakers, ammeters, voltmeters, selector switch, indicating lamps and termination of incoming & outgoing cable complete as per specifications and drawings.MDB-LIVE STOCKINCOMER1Nos.500Amp FP moulded case circuit breaker (35KA Ics value) with microprocessor release for O/L,S/C & EF Protection.INSTRUMENTS1 No. 0 to 500 Volt voltmeter with selector switch.1 No. 0 to 400Amp ammeter with selector switch and CT’s.1 Set of phase indicating lamps (RYB) with protection MCB.Electronic type Digital Multifunction Meter having 30 day memory and parameters of voltage, current, active power (kW), reactive power (KWAr), apparent power (KVA), power factor, phase angle, frequency, power demand, active energy (kWH), reactive energy (KVArh), apparent energy (KVAh), voltage & current harmonic etc compatible with PC through RS 485 communication BUSBARS500 Amp TPN aluminium busbars.OUTGOING5 Nos. 160Amp triple pole moulded case circuit breaker with neutral link (35 KA Ics value) with Thermal Magnetic release for O/L & S/C protection.2 Nos. 125 Amp triple pole moulded case circuit breaker with neutral link (35 KA Ics value) with Thermal Magnetic release for O/L & S/C protection.4 No. 63 Amp triple pole moulded case circuit breaker with neutral link (35 KA Ics value) with Thermal Magnetic release for O/L & S/C protection.

1

-

-

... More
MDB-VETERINARY ANATOMYINCOMER1Nos.630Amp FP moulded case circuit breaker (35KA Ics value) with microprocessor release for O/L,S/C & EF Protection.INSTRUMENTS1 No. 0 to 500 Volt voltmeter with selector switch.1 No. 0 to 630Amp ammeter with selector switch and CT’s.1 Set of phase indicating lamps (RYB) with protection MCB.Electronic type Digital Multifunction Meter having 30 day memory and parameters of voltage, current, active power (kW), reactive power (KWAr), apparent power (KVA), power factor, phase angle, frequency, power demand, active energy (kWH), reactive energy (KVArh), apparent energy (KVAh), voltage & current harmonic etc compatible with PC through RS 485 communicationBUSBARS500 Amp TPN aluminium busbars.OUTGOING5 Nos. 200Amp triple pole moulded case circuit breaker with neutral link (35 KA Ics value) with Thermal Magnetic release for O/L & S/C protection.2 Nos. 160 Amp triple pole moulded case circuit breaker with neutral link (35 KA Ics value) with Thermal Magnetic release for O/L & S/C protection.4 No. 63 Amp triple pole moulded case circuit breaker with neutral link (35 KA Ics value) with Thermal Magnetic release for O/L & S/C protection.

1

-

-

... More
MDB-VETERINARY PATHOLOGYINCOMER1 Nos.630Amp FP moulded case circuit breaker (35KA Ics value) with microprocessor release for O/L,S/C & EF Protection.INSTRUMENTS1 No. 0 to 500 Volt voltmeter with selector switch.1 No. 0 to 630Amp ammeter with selector switch and CT’s.1 Set of phase indicating lamps (RYB) with protection MCB.Electronic type Digital Multifunction Meter having 30 day memory and parameters of voltage, current, active power (kW), reactive power (KWAr), apparent power (KVA), power factor, phase angle, frequency, power demand, active energy (kWH), reactive energy (KVArh), apparent energy (KVAh), voltage & current harmonic etc compatible with PC through RS 485 communication BUSBARS500 Amp TPN aluminium busbars.OUTGOING5 Nos. 200Amp triple pole moulded case circuit breaker with neutral link (35 KA Ics value) with Thermal Magnetic release for O/L & S/C protection.2 Nos. 125Amp triple pole moulded case circuit breaker with neutral link (35 KA Ics value) with Thermal Magnetic release for O/L & S/C protection.4 No. 63 Amp triple pole moulded case circuit breaker with neutral link (35 KA Ics value) with Thermal Magnetic release for O/L & S/C protection.

1

-

-

... More
MDB-VETERINARY SURGERY & RADIOLOGYINCOMER1 Nos.630Amp FP moulded case circuit breaker (35KA Ics value) with microprocessor release for O/L,S/C & EF Protection.INSTRUMENTS1 No. 0 to 500 Volt voltmeter with selector switch.1 No. 0 to 630Amp ammeter with selector switch and CT’s.1 Set of phase indicating lamps (RYB) with protection MCB.Electronic type Digital Multifunction Meter having 30 day memory and parameters of voltage, current, active power (kW), reactive power (KWAr), apparent power (KVA), power factor, phase angle, frequency, power demand, active energy (kWH), reactive energy (KVArh), apparent energy (KVAh), voltage & current harmonic etc compatible with PC through RS 485 communication BUSBARS500 Amp TPN aluminium busbars.OUTGOING5 Nos. 200Amp triple pole moulded case circuit breaker with neutral link (35 KA Ics value) with Thermal Magnetic release for O/L & S/C protection.2 Nos. 125Amp triple pole moulded case circuit breaker with neutral link (35 KA Ics value) with Thermal Magnetic release for O/L & S/C protection. 2 Nos. 100 Amp triple pole moulded case circuit breaker with neutral link (35 KA Ics value) with Thermal Magnetic release for O/L & S/C protection.4 Nos. 63 Amp triple pole moulded case circuit breaker with neutral link (35 KA Ics value) with Thermal Magnetic release for O/L & S/C protection.

1

-

-

... More
MDB-(DEPTT OF FARMER) (4E)INCOMER1 Nos.400Amp FP moulded case circuit breaker (35KA Ics value) with microprocessor release for O/L,S/C & EF Protection.INSTRUMENTS1 No. 0 to 500 Volt voltmeter with selector switch.1 No. 0 to 400Amp ammeter with selector switch and CT’s.1 Set of phase indicating lamps (RYB) with protection MCB.Electronic type Digital Multifunction Meter having 30 day memory and parameters of voltage, current, active power (kW), reactive power (KWAr), apparent power (KVA), power factor, phase angle, frequency, power demand, active energy (kWH), reactive energy (KVArh), apparent energy (KVAh), voltage & current harmonic etc compatible with PC through RS 485 communication BUSBARS500 Amp TPN aluminium busbars.OUTGOING6 Nos. 125Amp triple pole moulded case circuit breaker with neutral link (25 KA Ics value) with Thermal Magnetic release for O/L & S/C protection.4 Nos. 63 Amp triple pole moulded case circuit breaker with neutral link (25 KA Ics value) with Thermal Magnetic release for O/L & S/C protection.

1

-

-

... More
MDB-HOSPITAL BLOCKINCOMER1 Nos.500Amp FP moulded case circuit breaker (35KA Ics value) with microprocessor release for O/L,S/C & EF Protection.INSTRUMENTS1 No. 0 to 500 Volt voltmeter with selector switch.1 No. 0 to 500Amp ammeter with selector switch and CT’s.1 Set of phase indicating lamps (RYB) with protection MCB.Electronic type Digital Multifunction Meter having 30 day memory and parameters of voltage, current, active power (kW), reactive power (KWAr), apparent power (KVA), power factor, phase angle, frequency, power demand, active energy (kWH), reactive energy (KVArh), apparent energy (KVAh), voltage & current harmonic etc compatible with PC through RS 485 communication BUSBARS600 Amp TPN aluminium busbars.OUTGOING6 Nos. 160Amp triple pole moulded case circuit breaker with neutral link (35 KA Ics value) with Thermal Magnetic release for O/L & S/C protection.3 Nos. 125Amp triple pole moulded case circuit breaker with neutral link (35 KA Ics value) with Thermal Magnetic release for O/L & S/C protection.4 Nos. 63 Amp triple pole moulded case circuit breaker with neutral link (35 KA Ics value) with Thermal Magnetic release for O/L & S/C protection.

1

-

-

... More
MDB-LIBRARYINCOMER1Nos. 400Amp FP moulded case circuit breaker (25KA Ics value) with microprocessor release for O/L,S/C & EF Protection.INSTRUMENTS1 No. 0 to 500 Volt voltmeter with selector switch.1 No. 0 to 400 Amp ammeter with selector switch and CT’s.1 Set of phase indicating lamps (RYB) with protection MCB.Electronic type Digital Multifunction Meter having 30 day memory and parameters of voltage, current, active power (kW), reactive power (KWAr), apparent power (KVA), power factor, phase angle, frequency, power demand, active energy (kWH), reactive energy (KVArh), apparent energy (KVAh), voltage & current harmonic etc compatible with PC through RS 485 communication BUSBARS500 Amp TPN aluminium busbars.OUTGOING4Nos. 125Amp triple pole moulded case circuit breaker with neutral link (25 KA Ics value) with Thermal Magnetic release for O/L & S/C protection.10 Nos 40-63 FP Miniature Circuit Breaker (10KA)

1

-

-

... More
MDB-LECTURE HALLINCOMER1Nos.200Amp FP moulded case circuit breaker (35KA Ics value) with microprocessor release for O/L,S/C & EF Protection.INSTRUMENTS1 No. 0 to 500 Volt voltmeter with selector switch.1 No. 0 to 200Amp ammeter with selector switch and CT’s.1 Set of phase indicating lamps (RYB) with protection MCB.Electronic type Digital Multifunction Meter having 30 day memory and parameters of voltage, current, active power (kW), reactive power (KWAr), apparent power (KVA), power factor, phase angle, frequency, power demand, active energy (kWH), reactive energy (KVArh), apparent energy (KVAh), voltage & current harmonic etc compatible with PC through RS 485 communication BUSBARS300 Amp TPN aluminium busbars.OUTGOING6 Nos. 40-100Amp triple pole moulded case circuit breaker with neutral link (35 KA Ics value) with Thermal Magnetic release for O/L & S/C protection.

1

-

-

... More
MDB-HOSTELINCOMER1Nos.200Amp FP moulded case circuit breaker (35KA Ics value) with microprocessor release for O/L,S/C & EF Protection.INSTRUMENTS1 No. 0 to 500 Volt voltmeter with selector switch.1 No. 0 to 200Amp ammeter with selector switch and CT’s.1 Set of phase indicating lamps (RYB) with protection MCB.Electronic type Digital Multifunction Meter having 30 day memory and parameters of voltage, current, active power (kW), reactive power (KWAr), apparent power (KVA), power factor, phase angle, frequency, power demand, active energy (kWH), reactive energy (KVArh), apparent energy (KVAh), voltage & current harmonic etc compatible with PC through RS 485 communication BUSBARS300 Amp TPN aluminium busbars.OUTGOING10 Nos. 40-100Amp triple pole moulded case circuit breaker with neutral link (35 KA Ics value) with Thermal Magnetic release for O/L & S/C protection.

1

-

-

... More
MDB-DINING (DINING)INCOMER1Nos.160 Amp FP moulded case circuit breaker (35KA Ics value) with microprocessor release for O/L,S/C & EF Protection.INSTRUMENTS1 No. 0 to 500 Volt voltmeter with selector switch.1 No. 0 to 160Amp ammeter with selector switch and CT’s.1 Set of phase indicating lamps (RYB) with protection MCB.Electronic type Digital Multifunction Meter having 30 day memory and parameters of voltage, current, active power (kW), reactive power (KWAr), apparent power (KVA), power factor, phase angle, frequency, power demand, active energy (kWH), reactive energy (KVArh), apparent energy (KVAh), voltage & current harmonic etc compatible with PC through RS 485 communication BUSBARS200 Amp TPN aluminium busbars.OUTGOING6 Nos. 40-100Amp triple pole moulded case circuit breaker with neutral link (35 KA Ics value) with Thermal Magnetic release for O/L & S/C protection.

1

-

-

... More
MDB-GUEST HOUSEINCOMER1Nos.250Amp FP moulded case circuit breaker (35KA Ics value) with microprocessor release for O/L,S/C & EF Protection.INSTRUMENTS1 No. 0 to 500 Volt voltmeter with selector switch.1 No. 0 to 250Amp ammeter with selector switch and CT’s.1 Set of phase indicating lamps (RYB) with protection MCB.Electronic type Digital Multifunction Meter having 30 day memory and parameters of voltage, current, active power (kW), reactive power (KWAr), apparent power (KVA), power factor, phase angle, frequency, power demand, active energy (kWH), reactive energy (KVArh), apparent energy (KVAh), voltage & current harmonic etc compatible with PC through RS 485 communication BUSBARS300 Amp TPN aluminium busbars.OUTGOING8 Nos. 100Amp triple pole moulded case circuit breaker with neutral link (35 KA Ics value) with Thermal Magnetic release for O/L & S/C protection.2No. 63 Amp triple pole moulded case circuit breaker with neutral link (35 KA Ics value) with Thermal Magnetic release for O/L & S/C protection.

1

-

-

... More
MDB-FARMER HOSTELINCOMER1Nos.160Amp FP moulded case circuit breaker (35KA Ics value) with microprocessor release for O/L,S/C & EF Protection.INSTRUMENTS1 No. 0 to 500 Volt voltmeter with selector switch.1 No. 0 to 160Amp ammeter with selector switch and CT’s.1 Set of phase indicating lamps (RYB) with protection MCB.Electronic type Digital Multifunction Meter having 30 day memory and parameters of voltage, current, active power (kW), reactive power (KWAr), apparent power (KVA), power factor, phase angle, frequency, power demand, active energy (kWH), reactive energy (KVArh), apparent energy (KVAh), voltage & current harmonic etc compatible with PC through RS 485 communication BUSBARS200 Amp TPN aluminium busbars.OUTGOING8 Nos. 40-100Amp triple pole moulded case circuit breaker with neutral link (35 KA Ics value) with Thermal Magnetic release for O/L & S/C protection.

1

-

-

... More
MDB-GIRL'S HOSTELINCOMER1Nos. 250Amp FP moulded case circuit breaker (25KA Ics value) with microprocessor release for O/L,S/C & EF Protection.INSTRUMENTS1 No. 0 to 500 Volt voltmeter with selector switch.1 No. 0 to 250Amp ammeter with selector switch and CT’s.1 Set of phase indicating lamps (RYB) with protection MCB.Electronic type Digital Multifunction Meter having 30 day memory and parameters of voltage, current, active power (kW), reactive power (KWAr), apparent power (KVA), power factor, phase angle, frequency, power demand, active energy (kWH), reactive energy (KVArh), apparent energy (KVAh), voltage & current harmonic etc compatible with PC through RS 485 communication BUSBARS300 Amp TPN aluminium busbars.OUTGOING5Nos. 125Amp triple pole moulded case circuit breaker with neutral link (25 KA Ics value) with Thermal Magnetic release for O/L & S/C protection.2 No. 63 Amp triple pole moulded case circuit breaker with neutral link (25 KA Ics value) with Thermal Magnetic release for O/L & S/C protection.

1

-

-

... More
MDB-BOYS HOSTELINCOMER1Nos. 250Amp FP moulded case circuit breaker (25KA Ics value) with microprocessor release for O/L,S/C & EF Protection.INSTRUMENTS1 No. 0 to 500 Volt voltmeter with selector switch.1 No. 0 to 250Amp ammeter with selector switch and CT’s.1 Set of phase indicating lamps (RYB) with protection MCB.Electronic type Digital Multifunction Meter having 30 day memory and parameters of voltage, current, active power (kW), reactive power (KWAr), apparent power (KVA), power factor, phase angle, frequency, power demand, active energy (kWH), reactive energy (KVArh), apparent energy (KVAh), voltage & current harmonic etc compatible with PC through RS 485 communication BUSBARS300 Amp TPN aluminium busbars.OUTGOING4Nos. 125Amp triple pole moulded case circuit breaker with neutral link (25 KA Ics value) with Thermal Magnetic release for O/L & S/C protection.2 No. 63 Amp triple pole moulded case circuit breaker with neutral link (25 KA Ics value) with Thermal Magnetic release for O/L & S/C protection.

1

-

-

... More
MDB-AUDITORIUMINCOMER1Nos.200Amp FP moulded case circuit breaker (35KA Ics value) with microprocessor release for O/L,S/C & EF Protection.INSTRUMENTS1 No. 0 to 500 Volt voltmeter with selector switch.1 No. 0 to 200Amp ammeter with selector switch and CT’s.1 Set of phase indicating lamps (RYB) with protection MCB.Electronic type Digital Multifunction Meter having 30 day memory and parameters of voltage, current, active power (kW), reactive power (KWAr), apparent power (KVA), power factor, phase angle, frequency, power demand, active energy (kWH), reactive energy (KVArh), apparent energy (KVAh), voltage & current harmonic etc compatible with PC through RS 485 communication BUSBARS300 Amp TPN aluminium busbars.OUTGOING6 Nos. 40-100Amp triple pole moulded case circuit breaker with neutral link (35 KA Ics value) with Thermal Magnetic release for O/L & S/C protection.

1

-

-

... More
SDB-GF (LIVE STOCK) TYPICAL FOR SDB-FF(LIVE STOCK) SDB-SF(LIVE STOCK) & SDB-TF(LIVE STOCK)INCOMER1Nos.160 Amp FP moulded case circuit breaker (35KA Ics value) with microprocessor release for O/L,S/C & EF Protection.INSTRUMENTS1 No. 0 to 500 Volt voltmeter with selector switch.1 No. 0 to 160Amp ammeter with selector switch and CT’s.1 Set of phase indicating lamps (RYB) with protection MCB.Electronic type Digital Multifunction Meter having 30 day memory and parameters of voltage, current, active power (kW), reactive power (KWAr), apparent power (KVA), power factor, phase angle, frequency, power demand, active energy (kWH), reactive energy (KVArh), apparent energy (KVAh), voltage & current harmonic etc compatible with PC through RS 485 communication BUSBARS200 Amp TPN aluminium busbars.OUTGOING6 Nos. 40-63Amp triple pole moulded case circuit breaker with neutral link (35 KA Ics value) with Thermal Magnetic release for O/L & S/C protection.6 Nos 40-63 FP Miniature Circuit Breaker (10KA)

4

-

-

... More
SDB-GF (VETERINARY ANATOMY) TYPICAL FOR SDB-FF(VETERINARY ANATOMY),SDB-SF(VETERINARY ANATOMY)INCOMER1Nos.200 Amp FP moulded case circuit breaker (35KA Ics value) with microprocessor release for O/L,S/C & EF Protection.INSTRUMENTS1 No. 0 to 500 Volt voltmeter with selector switch.1 No. 0 to 200Amp ammeter with selector switch and CT’s.1 Set of phase indicating lamps (RYB) with protection MCB.Electronic type Digital Multifunction Meter having 30 day memory and parameters of voltage, current, active power (kW), reactive power (KWAr), apparent power (KVA), power factor, phase angle, frequency, power demand, active energy (kWH), reactive energy (KVArh), apparent energy (KVAh), voltage & current harmonic etc compatible with PC through RS 485 communication BUSBARS300 Amp TPN aluminium busbars.OUTGOING6 Nos. 40-63Amp triple pole moulded case circuit breaker with neutral link (35 KA Ics value) with Thermal Magnetic release for O/L & S/C protection.6 Nos 40-63 FP Miniature Circuit Breaker (10KA)

3

-

-

... More
SDB-GF (VETERINARY PATHOLOGY) TYPICAL FOR SDB-FF(VETERINARY PATHOLOGY) & SDB-SF (VETERINARY PATHOLOGY),INCOMER1Nos.200 Amp FP moulded case circuit breaker (35KA Ics value) with microprocessor release for O/L,S/C & EF Protection.INSTRUMENTS1 No. 0 to 500 Volt voltmeter with selector switch.1 No. 0 to 200Amp ammeter with selector switch and CT’s.1 Set of phase indicating lamps (RYB) with protection MCB.Electronic type Digital Multifunction Meter having 30 day memory and parameters of voltage, current, active power (kW), reactive power (KWAr), apparent power (KVA), power factor, phase angle, frequency, power demand, active energy (kWH), reactive energy (KVArh), apparent energy (KVAh), voltage & current harmonic etc compatible with PC through RS 485 communication BUSBARS300 Amp TPN aluminium busbars.OUTGOING6 Nos. 40-63Amp triple pole moulded case circuit breaker with neutral link (35 KA Ics value) with Thermal Magnetic release for O/L & S/C protection.6 Nos 40-63 FP Miniature Circuit Breaker (10KA)

3

-

-

... More
SDB-GF (VETERINARY SURGERY & RADIOLOGY) TYPICAL FOR SDB-FF, SDB-SF INCOMER1Nos.200 Amp FP moulded case circuit breaker (35KA Ics value) with microprocessor release for O/L,S/C & EF Protection.INSTRUMENTS1 No. 0 to 500 Volt voltmeter with selector switch.1 No. 0 to 200Amp ammeter with selector switch and CT’s.1 Set of phase indicating lamps (RYB) with protection MCB.Electronic type Digital Multifunction Meter having 30 day memory and parameters of voltage, current, active power (kW), reactive power (KWAr), apparent power (KVA), power factor, phase angle, frequency, power demand, active energy (kWH), reactive energy (KVArh), apparent energy (KVAh), voltage & current harmonic etc compatible with PC through RS 485 communication BUSBARS300 Amp TPN aluminium busbars.OUTGOING6 Nos. 40-63Amp triple pole moulded case circuit breaker with neutral link (35 KA Ics value) with Thermal Magnetic release for O/L & S/C protection.6 Nos 40-63 FP Miniature Circuit Breaker (10KA)

3

-

-

... More
SDB-GF/FF/SF/TF (DEPTT OF FARMER) (4E)INCOMER1Nos.125 Amp FP moulded case circuit breaker (35KA Ics value) with microprocessor release for O/L,S/C & EF Protection.INSTRUMENTS1 No. 0 to 500 Volt voltmeter with selector switch.1 No. 0 to 200Amp ammeter with selector switch and CT’s.1 Set of phase indicating lamps (RYB) with protection MCB.Electronic type Digital Multifunction Meter having 30 day memory and parameters of voltage, current, active power (kW), reactive power (KWAr), apparent power (KVA), power factor, phase angle, frequency, power demand, active energy (kWH), reactive energy (KVArh), apparent energy (KVAh), voltage & current harmonic etc compatible with PC through RS 485 communication BUSBARS300 Amp TPN aluminium busbars.OUTGOING6 Nos 40-63 FP Miniature Circuit Breaker (10KA)

4

-

-

... More
SDB-GF-1 (HOSPITAL) TYPICAL FOR SDB-GF-2 (HOSPITAL) TYPIACL FOR SDB-FF-1 AND SDB-FF-2INCOMER1Nos.160 Amp FP moulded case circuit breaker (35KA Ics value) with microprocessor release for O/L,S/C & EF Protection.INSTRUMENTS1 No. 0 to 500 Volt voltmeter with selector switch.1 No. 0 to 200Amp ammeter with selector switch and CT’s.1 Set of phase indicating lamps (RYB) with protection MCB.Electronic type Digital Multifunction Meter having 30 day memory and parameters of voltage, current, active power (kW), reactive power (KWAr), apparent power (KVA), power factor, phase angle, frequency, power demand, active energy (kWH), reactive energy (KVArh), apparent energy (KVAh), voltage & current harmonic etc compatible with PC through RS 485 communication BUSBARS300 Amp TPN aluminium busbars.OUTGOING6 Nos. 40-63Amp triple pole moulded case circuit breaker with neutral link (35 KA Ics value) with Thermal Magnetic release for O/L & S/C protection.6 Nos 40-63 FP Miniature Circuit Breaker (10KA)

4

-

-

... More
SDB-GF-1 (GH) TYPICAL FOR SDB-FF-1 (GH),SDB-SF-1,INCOMER1Nos.100 Amp FP moulded case circuit breaker (35KA Ics value) with microprocessor release for O/L,S/C & EF Protection.INSTRUMENTS1 No. 0 to 500 Volt voltmeter with selector switch.1 No. 0 to 100Amp ammeter with selector switch and CT’s.1 Set of phase indicating lamps (RYB) with protection MCB.Electronic type Digital Multifunction Meter having 30 day memory and parameters of voltage, current, active power (kW), reactive power (KWAr), apparent power (KVA), power factor, phase angle, frequency, power demand, active energy (kWH), reactive energy (KVArh), apparent energy (KVAh), voltage & current harmonic etc compatible with PC through RS 485 communication BUSBARS200 Amp TPN aluminium busbars.OUTGOING6 Nos. 40-63Amp triple pole moulded case circuit breaker with neutral link (35 KA Ics value) with Thermal Magnetic release for O/L & S/C protection.

3

-

-

... More
SDB-GF/FF/SF/TF (GIRL'S HOSTEL) INCOMER1Nos.125 Amp FP moulded case circuit breaker (35KA Ics value) with microprocessor release for O/L,S/C & EF Protection.INSTRUMENTS1 No. 0 to 500 Volt voltmeter with selector switch.1 No. 0 to 200Amp ammeter with selector switch and CT’s.1 Set of phase indicating lamps (RYB) with protection MCB.Electronic type Digital Multifunction Meter with Voltage & current metering alongwith required CTs.BUSBARS300 Amp TPN aluminium busbars.OUTGOING6 Nos 40-63 FP Miniature Circuit Breaker (10KA)

4

-

-

... More
SDB-GF/FF/SF/TF (BOYS HOSTEL) INCOMER1Nos.125 Amp FP moulded case circuit breaker (35KA Ics value) with microprocessor release for O/L,S/C & EF Protection.INSTRUMENTS1 No. 0 to 500 Volt voltmeter with selector switch.1 No. 0 to 200Amp ammeter with selector switch and CT’s.1 Set of phase indicating lamps (RYB) with protection MCB.Electronic type Digital Multifunction Meter with Voltage & current metering along with required CTs.BUSBARS300 Amp TPN aluminium busbars.OUTGOING6 Nos 40-63 FP Miniature Circuit Breaker (10KA)

3

-

-

... More
MAIN PANEL-UPS-1 (LIVE STOCK)INCOMER1Nos.125 Amp FP moulded case circuit breaker (35KA Ics value) with microprocessor release for O/L,S/C & EF Protection.INSTRUMENTS1 No. 0 to 500 Volt voltmeter with selector switch.1 No. 0 to 125Amp ammeter with selector switch and CT’s.1 Set of phase indicating lamps (RYB) with protection MCB.BUSBARS200 Amp TPN aluminium busbars.OUTGOING2Nos.100 Amp FP moulded case circuit breaker (35KA Ics value) with microprocessor release for O/L,S/C & EF Protection.

1

-

-

... More
MAIN PANEL-UPS-2 (LIVE STOCK)INCOMER2Nos.100 Amp FP moulded case circuit breaker (35KA Ics value) with microprocessor release for O/L,S/C & EF Protection.INSTRUMENTS1 No. 0 to 500 Volt voltmeter with selector switch.1 No. 0 to 160Amp ammeter with selector switch and CT’s.1 Set of phase indicating lamps (RYB) with protection MCB.BUSBARS200 Amp TPN aluminium busbars.OUTGOING1 Nos. 125Amp triple pole moulded case circuit breaker with neutral link (35 KA Ics value) with Thermal Magnetic release for O/L & S/C protection.

1

-

-

... More
MDB-UPS (LIVE STOCK)INCOMER1Nos.125 Amp FP moulded case circuit breaker (35KA Ics value) with microprocessor release for O/L,S/C & EF Protection.INSTRUMENTS1 No. 0 to 500 Volt voltmeter with selector switch.1 No. 0 to 100Amp ammeter with selector switch and CT’s.1 Set of phase indicating lamps (RYB) with protection MCB.Electronic type Digital Multifunction Meter having 30 day memory and parameters of voltage, current, active power (kW), reactive power (KWAr), apparent power (KVA), power factor, phase angle, frequency, power demand, active energy (kWH), reactive energy (KVArh), apparent energy (KVAh), voltage & current harmonic etc compatible with PC through RS 485 communication BUSBARS200 Amp TPN aluminium busbars.OUTGOING6 Nos. 40-63Amp triple pole moulded case circuit breaker with neutral link (35 KA Ics value) with Thermal Magnetic release for O/L & S/C protection.

1

-

-

... More
SDB-UPS (GF) (LIVE STOCK) TYPICAL FOR SDB-UPS(FF), SDB-UPS(SF),SDB-UPS(TF)INCOMER1Nos.63 Amp FP moulded case circuit breaker (35KA Ics value) with microprocessor release for O/L,S/C & EF Protection.INSTRUMENTS1 No. 0 to 500 Volt voltmeter with selector switch.1 No. 0 to 63Amp ammeter with selector switch and CT’s.1 Set of phase indicating lamps (RYB) with protection MCB.Electronic type Digital Multifunction Meter having 30 day memory and parameters of voltage, current, active power (kW), reactive power (KWAr), apparent power (KVA), power factor, phase angle, frequency, power demand, active energy (kWH), reactive energy (KVArh), apparent energy (KVAh), voltage & current harmonic etc compatible with PC through RS 485 communication BUSBARS150Amp TPN aluminium busbars.OUTGOING6 Nos 32-40 FP Miniature Circuit Breaker (10KA)

4

-

-

... More
MAIN PANEL-UPS-1 (VETERINARY ANATOMY)INCOMER1Nos.160 Amp FP moulded case circuit breaker (35KA Ics value) with microprocessor release for O/L,S/C & EF Protection.INSTRUMENTS1 No. 0 to 500 Volt voltmeter with selector switch.1 No. 0 to 160Amp ammeter with selector switch and CT’s.1 Set of phase indicating lamps (RYB) with protection MCB.BUSBARS200 Amp TPN aluminium busbars.OUTGOING3Nos.100 Amp FP moulded case circuit breaker (35KA Ics value) with microprocessor release for O/L,S/C & EF Protection.

1

-

-

... More
MAIN PANEL-UPS-2 (VETERINARY ANATOMY)INCOMER3Nos.100 Amp FP moulded case circuit breaker (35KA Ics value) with microprocessor release for O/L,S/C & EF Protection.INSTRUMENTS1 No. 0 to 500 Volt voltmeter with selector switch.1 No. 0 to 160Amp ammeter with selector switch and CT’s.1 Set of phase indicating lamps (RYB) with protection MCB.BUSBARS200 Amp TPN aluminium busbars.OUTGOING1 Nos. 160Amp triple pole moulded case circuit breaker with neutral link (35 KA Ics value) with Thermal Magnetic release for O/L & S/C protection.

1

-

-

... More
MDB-UPS (VETERINARY ANATOMY)INCOMER1Nos.160 Amp FP moulded case circuit breaker (35KA Ics value) with microprocessor release for O/L,S/C & EF Protection.INSTRUMENTS1 No. 0 to 500 Volt voltmeter with selector switch.1 No. 0 to 160Amp ammeter with selector switch and CT’s.1 Set of phase indicating lamps (RYB) with protection MCB.Electronic type Digital Multifunction Meter having 30 day memory and parameters of voltage, current, active power (kW), reactive power (KWAr), apparent power (KVA), power factor, phase angle, frequency, power demand, active energy (kWH), reactive energy (KVArh), apparent energy (KVAh), voltage & current harmonic etc compatible with PC through RS 485 communication BUSBARS200 Amp TPN aluminium busbars.OUTGOING6 Nos. 40-100Amp triple pole moulded case circuit breaker with neutral link (35 KA Ics value) with Thermal Magnetic release for O/L & S/C protection.

1

-

-

... More
SDB-UPS (GF) (VETERINARY ANATOMY) TYPICAL FOR SDB-UPS(FF) (VETERINARY ANATOMY), SDB-UPS(SF) (VETERINARY ANATOMY),INCOMER1Nos.63-100 Amp FP moulded case circuit breaker (35KA Ics value) with microprocessor release for O/L,S/C & EF Protection.INSTRUMENTS1 No. 0 to 500 Volt voltmeter with selector switch.1 No. 0 to 100Amp ammeter with selector switch and CT’s.1 Set of phase indicating lamps (RYB) with protection MCB.Electronic type Digital Multifunction Meter having 30 day memory and parameters of voltage, current, active power (kW), reactive power (KWAr), apparent power (KVA), power factor, phase angle, frequency, power demand, active energy (kWH), reactive energy (KVArh), apparent energy (KVAh), voltage & current harmonic etc compatible with PC through RS 485 communication BUSBARS150Amp TPN aluminium busbars.OUTGOING6 Nos 32-40 FP Miniature Circuit Breaker (10KA)

3

-

-

... More
MAIN PANEL-UPS-1 (VETERINARY PATHOLOGY)INCOMER1Nos.125 Amp FP moulded case circuit breaker (35KA Ics value) with microprocessor release for O/L,S/C & EF Protection.INSTRUMENTS1 No. 0 to 500 Volt voltmeter with selector switch.1 No. 0 to 125Amp ammeter with selector switch and CT’s.1 Set of phase indicating lamps (RYB) with protection MCB.BUSBARS200 Amp TPN aluminium busbars.OUTGOING2Nos.100 Amp FP moulded case circuit breaker (35KA Ics value) with microprocessor release for O/L,S/C & EF Protection.

1

-

-

... More
MAIN PANEL-UPS-2 (VETERINARY PATHOLOGY)INCOMER2Nos.100 Amp FP moulded case circuit breaker (35KA Ics value) with microprocessor release for O/L,S/C & EF Protection.INSTRUMENTS1 No. 0 to 500 Volt voltmeter with selector switch.1 No. 0 to 160Amp ammeter with selector switch and CT’s.1 Set of phase indicating lamps (RYB) with protection MCB.BUSBARS200 Amp TPN aluminium busbars.OUTGOING1 Nos. 125Amp triple pole moulded case circuit breaker with neutral link (35 KA Ics value) with Thermal Magnetic release for O/L & S/C protection.

1

-

-

... More
MDB-UPS (VETERINARY ANATOMY)INCOMER1Nos.125 Amp FP moulded case circuit breaker (35KA Ics value) with microprocessor release for O/L,S/C & EF Protection.INSTRUMENTS1 No. 0 to 500 Volt voltmeter with selector switch.1 No. 0 to 160Amp ammeter with selector switch and CT’s.1 Set of phase indicating lamps (RYB) with protection MCB.Electronic type Digital Multifunction Meter having 30 day memory and parameters of voltage, current, active power (kW), reactive power (KWAr), apparent power (KVA), power factor, phase angle, frequency, power demand, active energy (kWH), reactive energy (KVArh), apparent energy (KVAh), voltage & current harmonic etc compatible with PC through RS 485 communication BUSBARS200 Amp TPN aluminium busbars.OUTGOING6 Nos. 40-100Amp triple pole moulded case circuit breaker with neutral link (35 KA Ics value) with Thermal Magnetic release for O/L & S/C protection.

1

-

-

... More
SDB-UPS (GF) (VETERINARY PATHOLOGY) TYPICAL FOR SDB-UPS(FF) (VETERINARY PATHOLOGY) & SDB-UPS (SF) (VETERINARY PATHOLOGY) INCOMER1Nos.63-100 Amp FP moulded case circuit breaker (35KA Ics value) with microprocessor release for O/L,S/C & EF Protection.INSTRUMENTS1 No. 0 to 500 Volt voltmeter with selector switch.1 No. 0 to 100Amp ammeter with selector switch and CT’s.1 Set of phase indicating lamps (RYB) with protection MCB.Electronic type Digital Multifunction Meter having 30 day memory and parameters of voltage, current, active power (kW), reactive power (KWAr), apparent power (KVA), power factor, phase angle, frequency, power demand, active energy (kWH), reactive energy (KVArh), apparent energy (KVAh), voltage & current harmonic etc compatible with PC through RS 485 communication BUSBARS150Amp TPN aluminium busbars.OUTGOING6 Nos 32-40 FP Miniature Circuit Breaker (10KA)

3

-

-

... More
MAIN PANEL-UPS-1 (VETERINARY SURGERY & RADIOLOGY)INCOMER1Nos.125 Amp FP moulded case circuit breaker (35KA Ics value) with microprocessor release for O/L,S/C & EF Protection.INSTRUMENTS1 No. 0 to 500 Volt voltmeter with selector switch.1 No. 0 to 125Amp ammeter with selector switch and CT’s.1 Set of phase indicating lamps (RYB) with protection MCB.BUSBARS200 Amp TPN aluminium busbars.OUTGOING2Nos.100 Amp FP moulded case circuit breaker (35KA Ics value) with microprocessor release for O/L,S/C & EF Protection.

1

-

-

... More
MAIN PANEL-UPS-2 (VETERINARY SURGERY & RADIOLOGY)INCOMER2Nos.100 Amp FP moulded case circuit breaker (35KA Ics value) with microprocessor release for O/L,S/C & EF Protection.INSTRUMENTS1 No. 0 to 500 Volt voltmeter with selector switch.1 No. 0 to 160Amp ammeter with selector switch and CT’s.1 Set of phase indicating lamps (RYB) with protection MCB.BUSBARS200 Amp TPN aluminium busbars.OUTGOING1 Nos. 125Amp triple pole moulded case circuit breaker with neutral link (35 KA Ics value) with Thermal Magnetic release for O/L & S/C protection.

1

-

-

... More
MDB-UPS (VETERINARY SURGERY & RADIOLOGY)INCOMER1Nos.125 Amp FP moulded case circuit breaker (35KA Ics value) with microprocessor release for O/L,S/C & EF Protection.INSTRUMENTS1 No. 0 to 500 Volt voltmeter with selector switch.1 No. 0 to 125Amp ammeter with selector switch and CT’s.1 Set of phase indicating lamps (RYB) with protection MCB.Electronic type Digital Multifunction Meter having 30 day memory and parameters of voltage, current, active power (kW), reactive power (KWAr), apparent power (KVA), power factor, phase angle, frequency, power demand, active energy (kWH), reactive energy (KVArh), apparent energy (KVAh), voltage & current harmonic etc compatible with PC through RS 485 communication BUSBARS200 Amp TPN aluminium busbars.OUTGOING6 Nos. 40-100Amp triple pole moulded case circuit breaker with neutral link (35 KA Ics value) with Thermal Magnetic release for O/L & S/C protection.

1

-

-

... More
SDB-UPS (GF) (VETERINARY ANATOMY) TYPICAL FOR SDB-UPS(FF), SDB-UPS(SF)INCOMER1Nos.63-100 Amp FP moulded case circuit breaker (35KA Ics value) with microprocessor release for O/L,S/C & EF Protection.INSTRUMENTS1 No. 0 to 500 Volt voltmeter with selector switch.1 No. 0 to 100Amp ammeter with selector switch and CT’s.1 Set of phase indicating lamps (RYB) with protection MCB.Electronic type Digital Multifunction Meter having 30 day memory and parameters of voltage, current, active power (kW), reactive power (KWAr), apparent power (KVA), power factor, phase angle, frequency, power demand, active energy (kWH), reactive energy (KVArh), apparent energy (KVAh), voltage & current harmonic etc compatible with PC through RS 485 communication BUSBARS150Amp TPN aluminium busbars.OUTGOING6 Nos 32-40 FP Miniature Circuit Breaker (10KA)

3

-

-

... More
MAIN PANEL-UPS (DEPTT OF FARM LAND)INCOMER1Nos. 125 Amp FP moulded case circuit breaker (35KA Ics value) with microprocessor release for O/L,S/C & EF Protection.INSTRUMENTS1 No. 0 to 500 Volt voltmeter with selector switch.1 No. 0 to 125Amp ammeter with selector switch and CT’s.1 Set of phase indicating lamps (RYB) with protection MCB.BUSBARS200 Amp TPN aluminium busbars.OUTGOING6 Nos 32-40 FP Miniature Circuit Breaker (10KA)

1

-

-

... More
MAIN PANEL-UPS-1(HOSPITAL)INCOMER1Nos.125 Amp FP moulded case circuit breaker (35KA Ics value) with microprocessor release for O/L,S/C & EF Protection.INSTRUMENTS1 No. 0 to 500 Volt voltmeter with selector switch.1 No. 0 to 125Amp ammeter with selector switch and CT’s.1 Set of phase indicating lamps (RYB) with protection MCB.BUSBARS200 Amp TPN aluminium busbars.OUTGOING2Nos.100 Amp FP moulded case circuit breaker (35KA Ics value) with microprocessor release for O/L,S/C & EF Protection.

1

-

-

... More
MAIN PANEL-UPS-2 (HOSPITAL)INCOMER2Nos.100 Amp FP moulded case circuit breaker (35KA Ics value) with microprocessor release for O/L,S/C & EF Protection.INSTRUMENTS1 No. 0 to 500 Volt voltmeter with selector switch.1 No. 0 to 160Amp ammeter with selector switch and CT’s.1 Set of phase indicating lamps (RYB) with protection MCB.BUSBARS200 Amp TPN aluminium busbars.OUTGOING1 Nos. 125Amp triple pole moulded case circuit breaker with neutral link (35 KA Ics value) with Thermal Magnetic release for O/L & S/C protection.

1

-

-

... More
MDB-UPS (HOSPITAL)INCOMER1Nos.125 Amp FP moulded case circuit breaker (35KA Ics value) with microprocessor release for O/L,S/C & EF Protection.INSTRUMENTS1 No. 0 to 500 Volt voltmeter with selector switch.1 No. 0 to 125Amp ammeter with selector switch and CT’s.1 Set of phase indicating lamps (RYB) with protection MCB.Electronic type Digital Multifunction Meter having 30 day memory and parameters of voltage, current, active power (kW), reactive power (KWAr), apparent power (KVA), power factor, phase angle, frequency, power demand, active energy (kWH), reactive energy (KVArh), apparent energy (KVAh), voltage & current harmonic etc compatible with PC through RS 485 communication BUSBARS200 Amp TPN aluminium busbars.OUTGOING5 Nos. 40-100Amp triple pole moulded case circuit breaker with neutral link (35 KA Ics value) with Thermal Magnetic release for O/L & S/C protection.

2

-

-

... More
SDB-UPS (GF)-1& 2 (HOSPITAL) TYPICAL FOR SDB-UPS(FF1) & SDB-UPS(FF) 2 INCOMER1Nos.63-100 Amp FP moulded case circuit breaker (35KA Ics value) with microprocessor release for O/L,S/C & EF Protection.INSTRUMENTS1 No. 0 to 500 Volt voltmeter with selector switch.1 No. 0 to 100Amp ammeter with selector switch and CT’s.1 Set of phase indicating lamps (RYB) with protection MCB.Electronic type Digital Multifunction Meter having 30 day memory and parameters of voltage, current, active power (kW), reactive power (KWAr), apparent power (KVA), power factor, phase angle, frequency, power demand, active energy (kWH), reactive energy (KVArh), apparent energy (KVAh), voltage & current harmonic etc compatible with PC through RS 485 communication BUSBARS150Amp TPN aluminium busbars.OUTGOING6 Nos 32-40 FP Miniature Circuit Breaker (10KA)

4

-

-

... More
SDB-UPS (LIBRARY) INCOMER2Nos.125 Amp FP moulded case circuit breaker (35KA Ics value) with microprocessor release for O/L,S/C & EF Protection.INSTRUMENTS1 No. 0 to 500 Volt voltmeter with selector switch.1 No. 0 to 125Amp ammeter with selector switch and CT’s.1 Set of phase indicating lamps (RYB) with protection MCB.Electronic type Digital Multifunction Meter with Voltage & current metering along with required CTs.BUSBARS300 Amp TPN aluminium busbars.OUTGOING6 Nos 40-63 FP Miniature Circuit Breaker (10KA)

2

-

-

... More
MDB-UPS (LECTURE HALL) INCOMER1Nos.100 Amp FP moulded case circuit breaker (35KA Ics value) with microprocessor release for O/L,S/C & EF Protection.INSTRUMENTS1 No. 0 to 500 Volt voltmeter with selector switch.1 No. 0 to 100Amp ammeter with selector switch and CT’s.1 Set of phase indicating lamps (RYB) with protection MCB.Electronic type Digital Multifunction Meter having 30 day memory and parameters of voltage, current, active power (kW), reactive power (KWAr), apparent power (KVA), power factor, phase angle, frequency, power demand, active energy (kWH), reactive energy (KVArh), apparent energy (KVAh), voltage & current harmonic etc compatible with PC through RS 485 communication BUSBARS150 Amp TPN aluminium busbars.OUTGOING6 Nos 32-40 FP Miniature Circuit Breaker (10KA)

1

-

-

... More
MDB-UPS (HOSTEL & DINING)INCOMER1Nos.100 Amp FP moulded case circuit breaker (35KA Ics value) with microprocessor release for O/L,S/C & EF Protection.INSTRUMENTS1 No. 0 to 500 Volt voltmeter with selector switch.1 No. 0 to 100Amp ammeter with selector switch and CT’s.1 Set of phase indicating lamps (RYB) with protection MCB.Electronic type Digital Multifunction Meter having 30 day memory and parameters of voltage, current, active power (kW), reactive power (KWAr), apparent power (KVA), power factor, phase angle, frequency, power demand, active energy (kWH), reactive energy (KVArh), apparent energy (KVAh), voltage & current harmonic etc compatible with PC through RS 485 communication BUSBARS200 Amp TPN aluminium busbars.OUTGOING6 Nos. 32Amp DP Miniature Circuit Breaker (10KA)

1

-

-

... More
MDB-UPS (GH)INCOMER1Nos.100 Amp FP moulded case circuit breaker (35KA Ics value) with microprocessor release for O/L,S/C & EF Protection.INSTRUMENTS1 No. 0 to 500 Volt voltmeter with selector switch.1 No. 0 to 100Amp ammeter with selector switch and CT’s.1 Set of phase indicating lamps (RYB) with protection MCB.Electronic type Digital Multifunction Meter having 30 day memory and parameters of voltage, current, active power (kW), reactive power (KWAr), apparent power (KVA), power factor, phase angle, frequency, power demand, active energy (kWH), reactive energy (KVArh), apparent energy (KVAh), voltage & current harmonic etc compatible with PC through RS 485 communication BUSBARS200 Amp TPN aluminium busbars.OUTGOING9 Nos. 32-40Amp Double pole Miniature Circuit Breaker(10KA)

1

-

-

... More
MDB-UPS (FARMER HOSTEL)INCOMER1Nos.63 Amp FP moulded case circuit breaker (35KA Ics value) with microprocessor release for O/L,S/C & EF Protection.INSTRUMENTS1 No. 0 to 500 Volt voltmeter with selector switch.1 No. 0 to 63Amp ammeter with selector switch and CT’s.1 Set of phase indicating lamps (RYB) with protection MCB.Electronic type Digital Multifunction Meter having 30 day memory and parameters of voltage, current, active power (kW), reactive power (KWAr), apparent power (KVA), power factor, phase angle, frequency, power demand, active energy (kWH), reactive energy (KVArh), apparent energy (KVAh), voltage & current harmonic etc compatible with PC through RS 485 communication BUSBARS200 Amp TPN aluminium busbars.OUTGOING8 Nos. 32-40Amp Double pole Miniature Circuit Breaker(10KA)

1

-

-

... More
MDB-UPS (AUDITORIUM) INCOMER1Nos.100 Amp FP moulded case circuit breaker (35KA Ics value) with microprocessor release for O/L,S/C & EF Protection.INSTRUMENTS1 No. 0 to 500 Volt voltmeter with selector switch.1 No. 0 to 100Amp ammeter with selector switch and CT’s.1 Set of phase indicating lamps (RYB) with protection MCB.Electronic type Digital Multifunction Meter having 30 day memory and parameters of voltage, current, active power (kW), reactive power (KWAr), apparent power (KVA), power factor, phase angle, frequency, power demand, active energy (kWH), reactive energy (KVArh), apparent energy (KVAh), voltage & current harmonic etc compatible with PC through RS 485 communication BUSBARS150 Amp TPN aluminium busbars.OUTGOING6 Nos 32-40 FP Miniature Circuit Breaker (10KA)

1

-

-

... More
METER BOARD -AMENITYSupply, installation, testing & commissioning of cubicle totally enclosed free standing type / wall Mounted type moisture, dust and vermin proof Meter Board made out of 1.63 mm CRCA sheet steel complete with following switchgears & instruments, including ammeter, ammeter selector switch, voltmeter, voltmeter selector switch, indicating lamps, CT's, internal wiring with suitable size wires/ cable, interconnection, painting etc. as required. (TOTAL OF A TO C)INCOMING1 No.160Amp Four Pole Moulded Case Circuit Breaker of 25 KA (Ics Value) with Thermal Magnetic release for O/L & S/C Protection.1 Set of phase indicating lamps with single pole MCB.1 Set of Breaker 'ON' & 'OFF' indicating lamps.1 Set of multifunction meter with basic parameters like frequency, KW, KVA, KVAR, Power Factor, harmonics analyser etc. shall be suitable for BMS function with RS485 port for communication, MODBUS output protocolBUSBARSTPN Copper busbars of minimum of 200 Amps capacity with heat shrinkable coloured sleeves and i/c DMC / SMC busbars supports at required.OUTGOING8 Nos. meter chamber each of size 300mm x 400mm having 6mm thick bakelite sheet and each meter chamber consisting of following :-Providing & fixing of 1 No. 0-30Amp. Single Phase Dual Source Energy Meter (Electronics type).1 No.32Amp Double Pole Miniature Circuit Breaker (10KA).3Nos. meter chamber each of size 300mm x 400mm having 6mm thick bakelite sheet and each meter chamber consisting of following :-Providing & fixing of 1 No. 0-40Amp. Three Phase Dual Source Energy Meter (Electronics type).1 No.40Amp Double Pole Miniature Circuit Breaker (10KA).

1

-

-

... More
METER BOARD -STAFF QTRS. 1 (3BHK)Supply, installation, testing & commissioning of cubicle totally enclosed free standing type / wall Mounted type moisture, dust and vermin proof Meter Board made out of 1.63 mm CRCA sheet steel complete with following switchgears & instruments, including ammeter, ammeter selector switch, voltmeter, voltmeter selector switch, indicating lamps, CT's, internal wiring with suitable size wires/ cable, interconnection, painting etc. as required. (TOTAL OF A TO C)INCOMING1 No.160Amp Four Pole Moulded Case Circuit Breaker of 25 KA (Ics Value) with Thermal Magnetic release for O/L & S/C Protection.1 Set of phase indicating lamps with single pole MCB.1 Set of Breaker 'ON' & 'OFF' indicating lamps.1 Set of multifunction meter with basic parameters like frequency, KW, KVA, KVAR, Power Factor, harmonics analyser etc. shall be suitable for BMS function with RS485 port for communication, MODBUS output protocolBUSBARSTPN Copper busbars of minimum of 200 Amps capacity with heat shrinkable coloured sleeves and i/c DMC / SMC busbars supports at required.OUTGOING8 Nos. meter chamber each of size 300mm x 400mm having 6mm thick bakelite sheet and each meter chamber consisting of following :-Providing & fixing of 1 No. 0-40Amp. Three Phase Dual Source Energy Meter (Electronics type).1 No.40Amp Four Pole Miniature Circuit Breaker (10KA).

1

-

-

... More
METER BOARD -STAFF QTRS. 2 (2BHK)Supply, installation, testing & commissioning of cubicle totally enclosed free standing type / wall Mounted type moisture, dust and vermin proof Meter Board made out of 1.63 mm CRCA sheet steel complete with following switchgears & instruments, including ammeter, ammeter selector switch, voltmeter, voltmeter selector switch, indicating lamps, CT's, internal wiring with suitable size wires/ cable, interconnection, painting etc. as required. (TOTAL OF A TO C)INCOMING1 No.125Amp Four Pole Moulded Case Circuit Breaker of 25 KA (Ics Value) with Thermal Magnetic release for O/L & S/C Protection.1 Set of phase indicating lamps with single pole MCB.1 Set of Breaker 'ON' & 'OFF' indicating lamps.1 Set of multifunction meter with basic parameters like frequency, KW, KVA, KVAR, Power Factor, harmonics analyser etc. shall be suitable for BMS function with RS485 port for communication, MODBUS output protocolBUSBARSTPN Copper busbars of minimum of 200 Amps capacity with heat shrinkable coloured sleeves and i/c DMC / SMC busbars supports at required.OUTGOING6 Nos. meter chamber each of size 300mm x 400mm having 6mm thick bakelite sheet and each meter chamber consisting of following :-Providing & fixing of 1 No. 0-40Amp. Three Phase Dual Source Energy Meter (Electronics type).1 No.40Amp Four Pole Miniature Circuit Breaker (10KA).

1

-

-

... More
METER BOARD -STAFF QTRS. 3 (1BHK)Supply, installation, testing & commissioning of cubicle totally enclosed free standing type / wall Mounted type moisture, dust and vermin proof Meter Board made out of 1.63 mm CRCA sheet steel complete with following switchgears & instruments, including ammeter, ammeter selector switch, voltmeter, voltmeter selector switch, indicating lamps, CT's, internal wiring with suitable size wires/ cable, interconnection, painting etc. as required. (TOTAL OF A TO C)INCOMING1 No.100Amp Four Pole Moulded Case Circuit Breaker of 25 KA (Ics Value) with Thermal Magnetic release for O/L & S/C Protection.1 Set of phase indicating lamps with single pole MCB.1 Set of Breaker 'ON' & 'OFF' indicating lamps.1 Set of multifunction meter with basic parameters like frequency, KW, KVA, KVAR, Power Factor, harmonics analyser etc. shall be suitable for BMS function with RS485 port for communication, MODBUS output protocolBUSBARSTPN Copper busbars of minimum of 150 Amps capacity with heat shrinkable coloured sleeves and i/c DMC / SMC busbars supports at required.OUTGOING6 Nos. meter chamber each of size 300mm x 400mm having 6mm thick bakelite sheet and each meter chamber consisting of following :-Providing & fixing of 1 No. 0-40Amp. Three Phase Dual Source Energy Meter (Electronics type).1 No.32Amp Four Pole Miniature Circuit Breaker (10KA).

1

-

-

... More
MDB-ADMIN 1 TYPICAL FOR MDB-ADMIN 2INCOMER1Nos.400Amp FP moulded case circuit breaker (35KA Ics value) with microprocessor release for O/L,S/C & EF Protection.INSTRUMENTS1 No. 0 to 500 Volt voltmeter with selector switch.1 No. 0 to 400Amp ammeter with selector switch and CT’s.1 Set of phase indicating lamps (RYB) with protection MCB.Electronic type Digital Multifunction Meter having 30 day memory and parameters of voltage, current, active power (kW), reactive power (KWAr), apparent power (KVA), power factor, phase angle, frequency, power demand, active energy (kWH), reactive energy (KVArh), apparent energy (KVAh), voltage & current harmonic etc compatible with PC through RS 485 communication BUSBARS500 Amp TPN aluminium busbars.OUTGOING6 Nos. 160Amp triple pole moulded case circuit breaker with neutral link (35 KA Ics value) with Thermal Magnetic release for O/L & S/C protection.3 Nos. 125Amp triple pole moulded case circuit breaker with neutral link (35 KA Ics value) with Thermal Magnetic release for O/L & S/C protection.2No. 63 Amp triple pole moulded case circuit breaker with neutral link (35 KA Ics value) with Thermal Magnetic release for O/L & S/C protection.

1

-

-

... More
SDB-GF-1 (ADMIN) TYPICAL FOR SDB-GF-2 (ADMIN)INCOMER1Nos.160 Amp FP moulded case circuit breaker (35KA Ics value) with microprocessor release for O/L,S/C & EF Protection.INSTRUMENTS1 No. 0 to 500 Volt voltmeter with selector switch.1 No. 0 to 200Amp ammeter with selector switch and CT’s.1 Set of phase indicating lamps (RYB) with protection MCB.Electronic type Digital Multifunction Meter having 30 day memory and parameters of voltage, current, active power (kW), reactive power (KWAr), apparent power (KVA), power factor, phase angle, frequency, power demand, active energy (kWH), reactive energy (KVArh), apparent energy (KVAh), voltage & current harmonic etc compatible with PC through RS 485 communication BUSBARS300 Amp TPN aluminium busbars.OUTGOING5 Nos. 40-63Amp triple pole moulded case circuit breaker with neutral link (35 KA Ics value) with Thermal Magnetic release for O/L & S/C protection.3 Nos 40-63 FP Miniature Circuit Breaker (10KA)

2

-

-

... More
SDB-FF-1 (ADMIN) TYPICAL FOR SDB-FF-2 (ADMIN), SDB-SF-1, SDB-SF-2, SDB-TF-1, SDB-TF-2INCOMER1Nos.160 Amp FP moulded case circuit breaker (35KA Ics value) with microprocessor release for O/L,S/C & EF Protection.INSTRUMENTS1 No. 0 to 500 Volt voltmeter with selector switch.1 No. 0 to 160Amp ammeter with selector switch and CT’s.1 Set of phase indicating lamps (RYB) with protection MCB.Electronic type Digital Multifunction Meter having 30 day memory and parameters of voltage, current, active power (kW), reactive power (KWAr), apparent power (KVA), power factor, phase angle, frequency, power demand, active energy (kWH), reactive energy (KVArh), apparent energy (KVAh), voltage & current harmonic etc compatible with PC through RS 485 communication BUSBARS200 Amp TPN aluminium busbars.OUTGOING6 Nos. 40-63Amp triple pole moulded case circuit breaker with neutral link (35 KA Ics value) with Thermal Magnetic release for O/L & S/C protection.5 Nos 40-63 FP Miniature Circuit Breaker (10KA)

6

-

-

... More
MAIN PANEL-UPS-1/ 1& 2 (ADMIN)INCOMER1Nos.125 Amp FP moulded case circuit breaker (35KA Ics value) with microprocessor release for O/L,S/C & EF Protection.INSTRUMENTS1 No. 0 to 500 Volt voltmeter with selector switch.1 No. 0 to 125Amp ammeter with selector switch and CT’s.1 Set of phase indicating lamps (RYB) with protection MCB.BUSBARS200 Amp TPN aluminium busbars.OUTGOING2Nos.100 Amp FP moulded case circuit breaker (35KA Ics value) with microprocessor release for O/L,S/C & EF Protection.

2

-

-

... More
MAIN PANEL-UPS-2/ 1& 2 (ADMIN )INCOMER2Nos.100 Amp FP moulded case circuit breaker (35KA Ics value) with microprocessor release for O/L,S/C & EF Protection.INSTRUMENTS1 No. 0 to 500 Volt voltmeter with selector switch.1 No. 0 to 160Amp ammeter with selector switch and CT’s.1 Set of phase indicating lamps (RYB) with protection MCB.BUSBARS200 Amp TPN aluminium busbars.OUTGOING1 Nos. 125Amp triple pole moulded case circuit breaker with neutral link (35 KA Ics value) with Thermal Magnetic release for O/L & S/C protection.

2

-

-

... More
MDB-UPS (ADMIN) 1 & 2INCOMER1Nos.125 Amp FP moulded case circuit breaker (35KA Ics value) with microprocessor release for O/L,S/C & EF Protection.INSTRUMENTS1 No. 0 to 500 Volt voltmeter with selector switch.1 No. 0 to 125Amp ammeter with selector switch and CT’s.1 Set of phase indicating lamps (RYB) with protection MCB.Electronic type Digital Multifunction Meter having 30 day memory and parameters of voltage, current, active power (kW), reactive power (KWAr), apparent power (KVA), power factor, phase angle, frequency, power demand, active energy (kWH), reactive energy (KVArh), apparent energy (KVAh), voltage & current harmonic etc compatible with PC through RS 485 communication BUSBARS200 Amp TPN aluminium busbars.OUTGOING5 Nos. 40-100Amp triple pole moulded case circuit breaker with neutral link (35 KA Ics value) with Thermal Magnetic release for O/L & S/C protection.

2

-

-

... More
SDB-UPS (GF)-1& 2 (ADMIN) TYPICAL FOR SDB-UPS(FF) 1& 2 & SDB-UPS(SF) 1 & 2 & SDB-UPS(TF) 1 & 2 INCOMER1Nos.63-100 Amp FP moulded case circuit breaker (35KA Ics value) with microprocessor release for O/L,S/C & EF Protection.INSTRUMENTS1 No. 0 to 500 Volt voltmeter with selector switch.1 No. 0 to 100Amp ammeter with selector switch and CT’s.1 Set of phase indicating lamps (RYB) with protection MCB.Electronic type Digital Multifunction Meter having 30 day memory and parameters of voltage, current, active power (kW), reactive power (KWAr), apparent power (KVA), power factor, phase angle, frequency, power demand, active energy (kWH), reactive energy (KVArh), apparent energy (KVAh), voltage & current harmonic etc compatible with PC through RS 485 communication BUSBARS150Amp TPN aluminium busbars.OUTGOING6 Nos 32-40 FP Miniature Circuit Breaker (10KA)

8

-

-

... More
LIGHTENING ARRESTER SYSTEMSupply, installation testing & commissioning of following 8 mm Aluminum Round Conductor complete as specified in drawing, according to (IS/IEC 62305),OBO Type No. RD 8/ALU I (5450086)

10270

-

-

... More
Roof conductor holder for parapet- Polyamide Conductor holder:With M8 female thread or diameter 7mm, M8 Screw to connect the conductor holder.Weather and temperature resistant from -35 to +90 degree Celsius tested. Conductor holder @ 1 meter distanceOBO Type No. 177 30 M8(5207460 )

10230

-

-

... More
Vertical air terminal with accessories:Providing of Air terminals as per IS-IEC -62305 part-3 Nominal size Ø10/16 mm aluminium rod: 2 Mtr Airterminal: semi-hard (E-AlMgSiO5 corresponds to DIN 48801) Suitable for high wind load.OBO Type No. 101 VL2000 ( 5401983)

58

-

-

... More
Providing of expansion piece with connector: For equalising temperature related length changes. Necessary on conductors length over 20 meters. For round conductor Rd 8/ALU. OBO Type No. 172 AR ( 5218 92 6 )

80

-

-

... More
Connector: For T cross and parallel connectors. Quick installation using hexagonal bolt M10X30 high-grade hot dip galvanised. Conforms to the requirements according to DIN VDE 0185-305 (IS-IEC 62305) (2 Nos for expansion piece) OBO Type No. 249 BST ( 5311705 )

80

-

-

... More
DOWN CONDUCTORSupply of 8 mm Aluminum Round Conductor complete as specified in drawing, according to (IS/IEC 62305),OBO Type No. RD 8/ALU I (5450086)

2485

-

-

... More
Supply of Roof conductor holder for parapet- Polyamide Conductor holder: With M8 female thread or diameter 7mm, M8 Screw to connect the conductor holder.Weather and temperature resistant from -35 to +90 degree Celsius tested. Conductor holder @ 1 meter distanceOBO Type No. 177 30 M8(5207460 )

2485

-

-

... More
Supply of Test Joint (Folding Clamp) suitable to connect 8mm round conductor and max by 30x3 mm GI strip as specified in drawing and directed by Engineer.OBO Type No. 271 8-10 ( 5317401 )

134

-

-

... More
Earthing Supply of UL Listed & CPRI Tested maintenance free ,Low carbon copper coated earth rod of 3 metre electrode having diameter of 14.2 mm with copper coating thickness of 250micron tested as per IEC 62561-2.OBO Type No. 14 3000 CCER(5450010)

139

-

-

... More
Universal clamp made of SS to connect rod with flat conductor.OBO Type No. 14 25 RTC(5450066)

139

-

-

... More
Earth conductivity enhancing compound shall be of 25 kg/pit tested as per IEC 62561-7,TCLP tested.OBO Type No. OEC 2 25(5450058)

139

-

-

... More
The above arrangements shall be provided with Heavy duty earth champer of 5000kg load bearing capacity to ensure the safety of earthing system.OBO Type No.UFE(5450030).

139

-

-

... More
Supplying, erecting, testing and commissioning of 30 kW DC Electric Vehicle Charger (suitable for 4 wheeler) having minimum IK08 & IP 54 Protection suitable for three phase, 415V AC, 50Hz incoming supply and 1 nos 30kW output charger interface CCS2 with 200-500VDC supply, Interlocking arrangement with minimum 4 meter charging cable length, 5" LCD Touch Screen for human interface & LED Light for status indication and metering for measurement of consumed energy having metering accuracy +/-1%, One hour battery backup for communication, emergency push stop button. User interface by mobile application/QR Code/RIFD Card/Password Login with payment options and having short circuit, over & under voltage, input phase reversal, surge protection, earth leakage protection and enclosure made of minimum 1.5mm duly RAL7035 coated M.S, erected on iron/GI frame on provided cement concrete foundation complete with one year on site warranty, confirming to IS 17017 Series as per specification

2

-

-

... More
Providing yearly subscription of payment gateway option for AC/DC EV Charger CMS (Charger management software) system for billing and payment gateway along with mobile application /android/IOS base app to facilitate charging, CMS should have ISO/IEC 27001:2003 certification.

1

-

-

... More
Supply, erection,testing & commissioning of 20HP,VRF/VRV air conditioning system outdoor unit(ODU) complies type-IV OEM standards working on HFC refrigerent R410A or other required/suitable green equivalent refrigerent, for minimum cooling capacity as delivering 100% capacity at 47degC, non stop cooling even at 56degC and coefficient of performance (COP) 3.00 to 4.00, modular type vertical hot air discharge suitable for longer piping range upto 1000m operation in cooling mode with inverters/digital VRF/VRV technology microprocessor based control compressor starter/control panel with scroll compressor,air cooled copper condenser coil of suitable shape for increasing maximum heat transfer area, rain protection cover,built in oil separator,accumulator and oil receiver,copper tube aluminium fin air cooled condenser ,condenser fan with motor suitable for 415V+/-10%,50Hz,3Phase power supply(all suitable for high ambient conditions),internal copper refrigerent piping,internal wiring and refrigerent ,etc all housed in powder coated weather proof cabinet complete.

9

-

-

... More
Supply, erection,testing & commissioning of 24HP,VRF/VRV air conditioning system outdoor unit(ODU) complies type-IV OEM standards working on HFC refrigerent R410A or other required/suitable green equivalent refrigerent, for minimum cooling capacity as delivering 100% capacity at 47degC, non stop cooling even at 56degC and coefficient of performance (COP) 3.00 to 4.00, modular type vertical hot air discharge suitable for longer piping range upto 1000m operation in cooling mode with inverters/digital VRF/VRV technology microprocessor based control compressor starter/control panel with scroll compressor,air cooled copper condenser coil of suitable shape for increasing maximum heat transfer area, rain protection cover,built in oil separator,accumulator and oil receiver,copper tube aluminium fin air cooled condenser ,condenser fan with motor suitable for 415V+/-10%,50Hz,3Phase power supply(all suitable for high ambient conditions),internal copper refrigerent piping,internal wiring and refrigerent ,etc all housed in powder coated weather proof cabinet complete.

4

-

-

... More
Supply, erection,testing & commissioning of 26HP,VRF/VRV air conditioning system outdoor unit(ODU) complies type-IV OEM standards working on HFC refrigerent R410A or other required/suitable green equivalent refrigerent, for minimum cooling capacity as delivering 100% capacity at 47degC, non stop cooling even at 56degC and coefficient of performance (COP) 3.00 to 4.00, modular type vertical hot air discharge suitable for longer piping range upto 1000m operation in cooling mode with inverters/digital VRF/VRV technology microprocessor based control compressor starter/control panel with scroll compressor,air cooled copper condenser coil of suitable shape for increasing maximum heat transfer area, rain protection cover,built in oil separator,accumulator and oil receiver,copper tube aluminium fin air cooled condenser ,condenser fan with motor suitable for 415V+/-10%,50Hz,3Phase power supply(all suitable for high ambient conditions),internal copper refrigerent piping,internal wiring and refrigerent ,etc all housed in powder coated weather proof cabinet complete.

4

-

-

... More
Supply, erection,testing & commissioning of 28HP,VRF/VRV air conditioning system outdoor unit(ODU) complies type-IV OEM standards working on HFC refrigerent R410A or other required/suitable green equivalent refrigerent, for minimum cooling capacity as delivering 100% capacity at 47degC, non stop cooling even at 56degC and coefficient of performance (COP) 3.00 to 4.00, modular type vertical hot air discharge suitable for longer piping range upto 1000m operation in cooling mode with inverters/digital VRF/VRV technology microprocessor based control compressor starter/control panel with scroll compressor,air cooled copper condenser coil of suitable shape for increasing maximum heat transfer area, rain protection cover,built in oil separator,accumulator and oil receiver,copper tube aluminium fin air cooled condenser ,condenser fan with motor suitable for 415V+/-10%,50Hz,3Phase power supply(all suitable for high ambient conditions),internal copper refrigerent piping,internal wiring and refrigerent ,etc all housed in powder coated weather proof cabinet complete.

2

-

-

... More
Supply, erection,testing & commissioning of 12HP,VRF/VRV air conditioning system outdoor unit(ODU) complies type-IV OEM standards working on HFC refrigerent R410A or other required/suitable green equivalent refrigerent, for minimum cooling capacity as delivering 100% capacity at 47degC, non stop cooling even at 56degC and coefficient of performance (COP) 3.00 to 4.00, modular type vertical hot air discharge suitable for longer piping range upto 1000m operation in cooling mode with inverters/digital VRF/VRV technology microprocessor based control compressor starter/control panel with scroll compressor,air cooled copper condenser coil of suitable shape for increasing maximum heat transfer area, rain protection cover,built in oil separator,accumulator and oil receiver,copper tube aluminium fin air cooled condenser ,condenser fan with motor suitable for 415V+/-10%,50Hz,3Phase power supply(all suitable for high ambient conditions),internal copper refrigerent piping,internal wiring and refrigerent ,etc all housed in powder coated weather proof cabinet complete.

1

-

-

... More
Supply, erection,testing & commissioning of 10HP,VRF/VRV air conditioning system outdoor unit(ODU) complies type-IV OEM standards working on HFC refrigerent R410A or other required/suitable green equivalent refrigerent, for minimum cooling capacity as delivering 100% capacity at 47degC, non stop cooling even at 56degC and coefficient of performance (COP) 3.00 to 4.00, modular type vertical hot air discharge suitable for longer piping range upto 1000m operation in cooling mode with inverters/digital VRF/VRV technology microprocessor based control compressor starter/control panel with scroll compressor,air cooled copper condenser coil of suitable shape for increasing maximum heat transfer area, rain protection cover,built in oil separator,accumulator and oil receiver,copper tube aluminium fin air cooled condenser ,condenser fan with motor suitable for 415V+/-10%,50Hz,3Phase power supply(all suitable for high ambient conditions),internal copper refrigerent piping,internal wiring and refrigerent ,etc all housed in powder coated weather proof cabinet complete.

1

-

-

... More
Supply, Installation, testing & commissioning of VRF/VRV based ceiling suspended 4Way cassette room/indoor unit (IDU-Compact/standard size) of nominal cooling capacity 3.0TR(1100 cfm) to 3.2TR (1165 cfm) having EER as per BEE standards and specifications, suitable as per site requirement with swing louvers and adjustable blades from sides. IDU with draingae arrangements,fan,refrigerent liquid and refrigerent piping,cordless remote control,and fresh air port etc. IDU shall have anti corrosive coating suitable for coastal area in all the respects suitable to operate on 1-phase,230V,50Hz,AC supply complete. Ths unit consisting with any additional refrigerent and oil charge as per requirement during installation.

40

-

-

... More
Supply, installation, testing and commissioning of VRF/VRV based Hi-wall type indoor unit (IDU) of nominal cooling capacity 1.3TR (421 cfm) to 1.7TR (586 cfm) having EER as per BEE standards and specifications with multiple speed evaporator fan with motor, copper tube aluminium fin evaporator coil, washable air filter, insulated drain tray, expansion device, cordless remote control with necessary controls, with 3-core copper flexible cord of required length and electrical terminal to receive power supply, etc. IDU shall have anticorrosive coating suitable for coastal area. Unit shall be suitable for indoor wall mounting, having an electronic control console, provided with suitable mounting brackets with any additional refrigerant and oil charge as per the requirement during installation, connected to the system complete.

1

-

-

... More
Supplying, installing, testing & commissioning split type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor. room air conditioning unit 1.0TR to 1.2 TR capacity having ISEER minimum 5.0 suitable to operate on 250V, 50 Hz, A.C. supply having 1 no of air handling unit hi-wall/floor mounting type complete with refrigerant R32 having copper condenser, minimum 2.5PM filter, self diagnosis feature, stabilizer free operation & temperature display on indoor unit, noise level maximum 50dBA at position in provided recess with wooden frame complete specification no. AP-AC/WAC

80

-

-

... More
Supplying, installing, testing & commissioning split type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor. room air conditioning unit 1.3TR to 1.6 TR capacity having ISEER minimum 5.0 suitable to operate on 250V, 50 Hz, A.C. supply having 1 no of air handling unit hi-wall/floor mounting type complete with refrigerant R32 having copper condenser, minimum 2.5PM filter, self diagnosis feature, stabilizer free operation & temperature display on indoor unit, noise level maximum 50dBA at position in provided recess with wooden frame complete specification no. AP-AC/WAC

50

-

-

... More
Supplying, installing, testing & commissioning split type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor. room air conditioning unit 1.7TR to 2.0TR capacity having ISEER minimum 5.0 suitable to operate on 250V, 50 Hz, A.C. supply having 1 no of air handling unit hi-wall/floor mounting type complete with refrigerant R32 having copper condenser, minimum 2.5PM filter, self diagnosis feature, stabilizer free operation & temperature display on indoor unit, noise level maximum 50dBA at position in provided recess with wooden frame complete specification no. AP-AC/WAC

20

-

-

... More
Supplying, installing, testing & commissioning cassette type room Air conditioning unit 4TR to 4.4TR capacity with refrigerant R32/410A 415V, 50 Hz, A.C. supply having 1 no of air handling unit (Mega split) mounting type complete with temperature display on indoor unit, minimum dust filter, noise level maximum 50dBA at position as per specification no. APAC/ WAC

22

-

-

... More
Supplying, installing, testing & commissioning cassette type room Air conditioning unit 3.4TR to 3.9TR capacity with refrigerant R32/410A 415V, 50 Hz, A.C. supply having 1 no of air handling unit (Mega split) mounting type complete with temperature display on indoor unit, minimum dust filter, noise level maximum 50dBA at position as per specification no. APAC/ WAC

4

-

-

... More
Supplying, installing, testing & commissioning cassette type room Air conditioning unit 2.8TR to 3.3TR capacity with refrigerant R32/410A 415V, 50 Hz, A.C. supply having 1 no of air handling unit (Mega split) mounting type complete with temperature display on indoor unit, minimum dust filter, noise level maximum 50dBA at position as per specification no. APAC/ WAC

6

-

-

... More
Supplying, installing, testing & commissioning cassette type room Air conditioning unit 2.5TR to 2.7TR capacity with refrigerant R32/410A 415V, 50 Hz, A.C. supply having 1 no of air handling unit (Mega split) mounting type complete with temperature display on indoor unit, minimum dust filter, noise level maximum 50dBA at position as per specification no. APAC/ WAC

4

-

-

... More
AIRHANDLING UNITS Supply, Installation, Testing & Commissioning of factory built floor mounted Horizontal DX coil double skin type AHU complete Aerofoil Plug fan , as detailed below, fire retardent flexible connections, direct drive fan, compatible with DX VRV outdoor condensing unit,Including suitable expansion Kits with corded remote controller,TEFC motor of class 'F' insulation, efficiency class IE-3 motor, suitable for operation on 415 + 10% volts, 3 phase, 50 Hz,including Motor with VFD of IP20 rating,Pre Filters , including all connected accessories, AC supply, thermal break profile, Drain connections, stainless steel drain pan complete with all fittings and accessories, necessary isolation arrangement, floor supports system complete as required & as specified with the following capacities. 15,000 cfm, 50 mmwg S.P, (ODU-2x24HP)

2

-

-

... More
13,000 cfm, 50 mmwg S.P, (ODU-2x20HP)

2

-

-

... More
3500 cfm, 135mmwg S.P, (ODU-1x12HP)

1

-

-

... More
2400 cfm, 135mmwg S.P, (ODU-1x10HP)

1

-

-

... More
Supply and Installation of high pressure grade required size copper connection Y or T-Joints/refnet complete erected on wall/ceiling with supports/raceways,nitrile rubber insulation,painting etc. with brazing and testing for leakages confirming the normal operation of the VRV/VRF air conditioning system.

67

-

-

... More
Supply, erecting , testing & commissioning of centralised programmable remote control panel(HMI) touch manager controls minimum 16 system of 64 ODU's can be controlled and up to 992 IDU's can be individually mounted and controlled indoor units having collour min 200mm size LCD touch panel,yearly schdule,power proportional distribution function,temperature limitation,history function complete erected on wall intergated with provided fire alarm system.

3

-

-

... More
Supplying, laying/fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 41.3mm dia (OD) for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports, hangers, clamps,vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19mm thick elastomeric nitrile rubber along with application of multicoating of VRV/VRF piping for protection against mechanical damages,fungal growth, flame spread, water permeance and ultra violet radiations with OEM standards of VRV/VRF air conditioning system complete.

4

-

-

... More
Supplying, laying/fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 34.9mm dia (OD) for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports, hangers, clamps,vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19mm thick elastomeric nitrile rubber along with application of multicoating of VRV/VRF piping for protection against mechanical damages,fungal growth, flame spread, water permeance and ultra violet radiations with OEM standards of VRV/VRF air conditioning system complete.

91

-

-

... More
Supplying, laying/fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 28.6mm dia (OD) for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports, hangers, clamps,vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19mm thick elastomeric nitrile rubber along with application of multicoating of VRV/VRF piping for protection against mechanical damages,fungal growth, flame spread, water permeance and ultra violet radiations with OEM standards of VRV/VRF air conditioning system complete.

183

-

-

... More
Supplying, laying/fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 22.2mm dia (OD) for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports, hangers, clamps,vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19mm thick elastomeric nitrile rubber along with application of multicoating of VRV/VRF piping for protection against mechanical damages,fungal growth, flame spread, water permeance and ultra violet radiations with OEM standards of VRV/VRF air conditioning system complete.

139

-

-

... More
Supplying, laying/fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 19.1mm dia (OD) for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports, hangers, clamps,vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19mm thick elastomeric nitrile rubber along with application of multicoating of VRV/VRF piping for protection against mechanical damages,fungal growth, flame spread, water permeance and ultra violet radiations with OEM standards of VRV/VRF air conditioning system complete.

61

-

-

... More
Supplying, laying/fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 15.9mm dia (OD) for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports, hangers, clamps,vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19mm thick elastomeric nitrile rubber along with application of multicoating of VRV/VRF piping for protection against mechanical damages,fungal growth, flame spread, water permeance and ultra violet radiations with OEM standards of VRV/VRF air conditioning system complete.

368

-

-

... More
Supplying, laying/fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 12.7mm dia (OD) for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports, hangers, clamps,vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19mm thick elastomeric nitrile rubber along with application of multicoating of VRV/VRF piping for protection against mechanical damages,fungal growth, flame spread, water permeance and ultra violet radiations with OEM standards of VRV/VRF air conditioning system complete.

145

-

-

... More
Supplying, laying/fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 9.5mm dia (OD) for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports, hangers, clamps,vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19mm thick elastomeric nitrile rubber along with application of multicoating of VRV/VRF piping for protection against mechanical damages,fungal growth, flame spread, water permeance and ultra violet radiations with OEM standards of VRV/VRF air conditioning system complete.

340

-

-

... More
Supplying, laying/fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 6.4mm dia (OD) for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports, hangers, clamps,vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19mm thick elastomeric nitrile rubber along with application of multicoating of VRV/VRF piping for protection against mechanical damages,fungal growth, flame spread, water permeance and ultra violet radiations with OEM standards of VRV/VRF air conditioning system complete.

31

-

-

... More
DUCT INSULATIONProviding adhesive thermal insulation for supply return air duct with 19mm nitrile rubber insulation having R-value as per the prevailing provisions in ECBC-201719 mm

900

-

-

... More
G.I. SHEET METAL DUCTING (RECTANGULAR)Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.Thickness 0.63 mm sheet (0 - 750 mm)

550

-

-

... More
Thickness 0.80 mm sheet (751- 1500 mm)

450

-

-

... More
Thickness 1.00 mm sheet (1501- 2250 mm)

76

-

-

... More
Thickness 1.25 mm sheet (Above 2250mm)

90

-

-

... More
Providing and applying of acoustic insulation for air ducts with 25mm thick, 48 kg/cu.m fiber glass faced with RP tissue and covered with 26 SWG perforated aluminium sheets complete.

175

-

-

... More
Supplying & fixing of powder coated extruded aluminium Supply/Return Air Grills with aluminium volume control dampers as per specifications.

23

-

-

... More
Supplying & fixing of powder coated extruded aluminium Return Air Grills with louvers but without volume control dampers complete as required.

9

-

-

... More
Supplying, fixing testing commissioning of supply air diffusers of powder coated aluminium with aluminium volume control dampers with anti smudge ring & removable core.

16

-

-

... More
Supplying, fixing testing commissioning of Return air diffusers of powder coated aluminium without volume control dampers with anti smudge ring & removable core.

16

-

-

... More
Supplying, Fixing, testing and commissioning of fire dampers in supply air duct/ main branch and return air path as and where required of required sizes i/c control wiring, the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal complete as required and as per specifications.Fire Dampers

10

-

-

... More
Actuators

16

-

-

... More
FRESH AIR GRILLESSupply and fixing of Aluminium extruded Fresh/intake/Exhaust air louvers with bird screen and without filter with damper complete as required and as per specification.

5

-

-

... More
VOLUME CONTROL DAMPERSupply, installation, testing and commissioning of manually operated, opposed blade, duct mounted, flanged volume control dampers of required sizes in GI construction with operating mechanism, mounting arrangement, rubber refrigerant kits etc. complete.

5

-

-

... More
WEATHER PROCTECTIVE COATING ON EXPOSED VRV PIPESSupply and applying of Fevicol Weather Protekt Coat or equivalent water based fire retardant coat, flexible, vapour barrier, high solid coat which imparts tough mechanical protection and durable seal against water, moisture & weathering. It is ideal for protecting all types of Insulation material used in Hot and Cold Insulation used in any type of Industrial / HVAC applications.(Exposed VRV pipes only)(TDS shall be submitted after approval only work will be done).

30

-

-

... More
DRAIN PIPINGProviding and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, fixing the pipe with clamps at 1.00 m spacing with necessary supports as per specifications and duly insulated with 9mm thick nitrile rubber insulation asper specification and drawings. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.50 mm dia

80

-

-

... More
40 mm dia

190

-

-

... More
32 mm dia

200

-

-

... More
25 mm dia

295

-

-

... More
DRAIN PIPINGSupplying and erecting HMS PVC conduit FRLS grade 25 mm dia. With necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC.

1630

-

-

... More
Supplying and erecting HMS PVC conduit FRLS grade 32 mm dia. With necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC.

505

-

-

... More
CONTROL & TRANSMISSION WIRINGSupply & fixing control cum transmission wiring of 2 core x 1.5 sqmm copper with PVC conduits as required.

3500

-

-

... More
Supply and installation of XLPE insulated, cores laid up, tape innersheathed, armoured copper cables for various equipments along with cable terminations lugs, metal glands, tagging with all accessories etc. through walls/ceiling with appropriate clamps & fixing arrangement for running on cable tray, as per specifications and drawings.4C-16 sqmm

40

-

-

... More
4C-10 sqmm

100

-

-

... More
4C-6 sqmm

150

-

-

... More
4C-4 sqmm

120

-

-

... More
3C-1.5 sqmm

360

-

-

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 80 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.600 mm width X 62.5 mm depth X 2.0 mm thickness

20

-

-

... More
450 mm width X 62.5 mm depth X 2.0 mm thickness

110

-

-

... More
300 mm width X 62.5 mm depth X 2.0 mm thickness

170

-

-

... More
150 mm width X 50 mm depth X 1.6 mm thickness

140

-

-

... More
Electrical Panel (Library)Design, manufacture, supply, installation, testing and commissioning weather proof panel, front operated, cubicle construction, floor mounted type, fabricated out of 1.6 mm thick CRCA Sheet, Compartmentalized with hinged lockable doors, dust and vermin proof, Powder coated of approved shade, Cable alley, inter-connections, KWH meter along with indication of phase ON, panel have provision of trip in case of earth leakage, limit switch with indoor lighting, metal lock system, proper ventilation louvers & fans having switch gear, voltmeter, ammeter, and accessories mounting, internal wiring, earth terminals, Top cable entry, numberings etc. Rubber mats as per IS requirements. BMS contactors on all outgoings for remote operation. suitable for operation of 415 volts, 3 phase, 4 wire, 50 Hz, AC Supply with enclosure protection class IP 55 complete as per specifications, BMS compatible- Modbus Protocol, requirement, standards and drawings with the following : 1 No.200 Amps INCOMING MCCB, 4P 1 set 250 Amps TPN Aluminium conductor bus bar duly sleeved.2 No.63 Amps TPN MCB-ELCB outgoing for 2 No. 20HP VRV ODU.1 No.40 Amps TPN MCCB outgoing for 1 No.5.5/7.5 KW AHU Motor with VFD (VFD suitable space shall be in panel ) with potential free NO/NC contacts for automatic OFF with fire signal, microprocessor based realesed.1 No.40 Amps TPN MCCB outgoing Spare1 No.63 Amps TPN MCB-ELCB outgoing Spare

2

-

-

... More
Electrical Panel (Auditorium)Design, manufacture, supply, installation, testing and commissioning weather proof panel, front operated, cubicle construction, floor mounted type, fabricated out of 1.6 mm thick CRCA Sheet, Compartmentalized with hinged lockable doors, dust and vermin proof, Powder coated of approved shade, Cable alley, inter-connections, KWH meter along with indication of phase ON, panel have provision of trip in case of earth leakage, limit switch with indoor lighting, metal lock system, proper ventilation louvers & fans having switch gear, voltmeter, ammeter, and accessories mounting, internal wiring, earth terminals, Top cable entry, numberings etc. Rubber mats as per IS requirements. BMS contactors on all outgoings for remote operation. suitable for operation of 415 volts, 3 phase, 4 wire, 50 Hz, AC Supply with enclosure protection class IP 55 complete as per specifications, BMS compatible- Modbus Protocol, requirement, standards and drawings with the following : 1 No.200 Amps INCOMING MCCB, 4P 1 set 250 Amps TPN Aluminium conductor bus bar duly sleeved.2 No.63 Amps TPN MCB-ELCB outgoing for 2 No. 24HP VRV ODU.1 No.40 Amps TPN MCCB outgoing for 1 No.5.5/7.5 KW AHU Motor with VFD (VFD suitable space shall be in panel ) with potential free NO/NC contacts for automatic OFF with fire signal, microprocessor based realesed.1 No.63 Amps TPN MCCB outgoing along with Star delta starter for 1 No.11.0/7.5 KW Axial fan Motor w with potential free NO/NC contacts for automatic ON with fire signal, microprocessor based realesed.1 No.40 Amps TPN MCCB outgoing Spare1 No.63 Amps TPN MCB-ELCB outgoing Spare

2

-

-

... More
EARTHINGProviding and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.

900

-

-

... More
ISOLATORSSupply & fixing of following rating weather proof IP-65 endosure isolators with all accessories as required for following as per specifications, standards & requirement for VRV ODU's.28HP

2

-

-

... More
26HP

4

-

-

... More
20HP

9

-

-

... More
12HP

1

-

-

... More
10HP

1

-

-

... More
Propeller FansSupply, installation, testing and commissioning of industrial type propeller fans with inbuilt gravity louvers,fan shall be directly driven, Motor shall be 230+/-,50Hz,1Ph, AC supply.300 mm dia,1400RPM

40

-

-

... More
200 mm dia,1400RPM

72

-

-

... More
Exhaust Fans - Axial Flow Type : (Fire rated : 250 deg for 2 Hrs. )Providing, fixing, testing and commissioning of AMCA Certified (For Air and Sound Performance) Vane axial flow fan of different capacity as mentioned below in standard M.S.contruction. Entire fan model & AMCA Seal shall appear in techncial submittal of fan. All the fans are synthetic enamelled panited/hot dip galvanized with minimum 220 GSM Zinc Coating and complete with bird screen at inlet. The electric motor coupler shall be squirrel cage induction motor (IE-2 type) confirming to IP - 55 with class `H' insulation. Motor shall be of high temperature resistance "Class H Smoke Spill" 250° C for 2 hrs. Fan efficiency should not be less than 65 %. All fans shall be fire retardent canvass connections & with factory fitted heavy gauge back draft damper. MS structure supports Fans should be as per specification and drawings.30,000 cfm, 40 mmwg S.P.(Audi Smoke Exhaust)

2

-

-

... More
WEATHER PROCTECTIVE COATING ON EXPOSED VRV PIPESSupply and applying of Fevicol Weather Protekt Coat or equivalent water based fire retardant coat, flexible, vapour barrier, high solid coat which imparts tough mechanical protection and durable seal against water, moisture & weathering. It is ideal for protecting all types of Insulation material used in Hot and Cold Insulation used in any type of Industrial / HVAC applications.(Exposed VRV pipes only)(TDS shall be submitted after approval only work will be done).

360

-

-

... More
AHU ROOM ACOUSTIC LININGSupplying, and fixing of acoustic lining on wall and ceiling of AHU rooms with 50mm thick,density 32kg/cu.m resin bonded glass fiber insulation friction fixed in 610mm x 610mm frame work made of 25x50x50x50x25 mm made out of 0.6mm thick GI sheet U shaped channel and covered with reinforced fiber glass tissue and finished with 0.80mm perforated aluminium sheet etc. complete as required and as per specifications.

200

-

-

... More
Supplying & erecting seamless outside & inside, smooth, dry and clean copper pipe with ROHS compliant suitable for refrigerant having 22SWG thickness and inner dia/size 12mm complete.

3500

-

-

... More
Supplying & erecting seamless outside & inside, smooth, dry and clean copper pipe with ROHS compliant suitable for refrigerant having 22SWG thickness and inner dia/size 16mm complete.

700

-

-

... More
Supplying and erecting elastomeric nitrile rubber / foam tube type sleeves for coating and insulating on provided PC / copper pipes having 9 mm thickness and inner diameter / sizes 12 mm for solar water heater/AC system.

3500

-

-

... More
Supplying and erecting elastomeric nitrile rubber / foam tube type sleeves for coating and insulating on provided PC / copper pipes having 9 mm thickness and inner diameter / sizes 16 mm for solar water heater/AC system.

455

-

-

... More
ISOLATORSSupply & fixing of following rating weather proof IP-65 endosure isolators with all accessories as required for following as per specifications, standards & requirement for VRV ODU's.24HP

2

-

-

... More
SITC of Electric Traction Passenger Lift with· Rated capacity :- 8 Passenger/544Kg· Floors :- G+2 floor (3 Stops/3 Landings)· Travel :- 3 to 4.2 mtrs· Location of Lift Machine:- MR/MRL· Rated speed :- 1.0 mps VS· Car/Landing door clear opening of 800 mm wide x 2000 mm high· Clear Car size of ......mm wide x ......mm deep x 2250mm high· Lift shaft available having clear size of 1900 mm wide x 1900 mm deep, ......mm Pit depth, ………mm Overhead.· Doors type :- COPO/TOPO Doors with frame made from SS 304 gradesolid(non-cladded) sheet of 1.5mm thick in hairline finish for car and all landingdoors with SS door architraves/frames The lift doors shall have minimum 1hour fire rating (with submission of necessary valid test certificate issuedby NABL accredited or Independent test laboratory).· Lift car enclosure made from SS 304 grade solid (non-cladded) sheet of1.5mm, thick with hairline finish with frame made from MS girders, bracing ofadequate size with minimum safety factor of 5, with Toe Guard Apron, withnecessary false ceiling with adequate LED lights, blower/fan for ventilation & SSchequered plate flooring, handrails, mirror, emergency light etc. The lift carinterior design shall be done as per the directions of engineer in charge.· COP with SS face plate having metallic push buttons with Braille code &luminous indicator around button with FPI, scrolling UP/DN LED indicator &with / without attendant key switch, OWD with audio-visual alarm, VAS inMarathi, Hindi & English with intercom system with telephone instrument in Liftcar, LMR & FCC/ground floor.· LOP with SS face plate having recess/surface push button box for alllandings with scrolling UP/DN LED indicator having metallic push buttons withBraille code & luminous indicator around button with CPI, Lift car arrival & nexttravel direction audio-visual indication at all landings.· Lift controller based on microprocessor/ PLC with VVVF Drive havingclosed loop control system, with IBMS compatible having necessary port. Thecontroller shall have necessary protections such as overcurrent, overvoltage, overspeed, overheat for all devices including lift motor and travel directionprotection, protection for phase loss at input or output etc. various operationmodes such as maintenance, change direction by attendant, full load bypass, VIPcall operation, self levelling operation, call cancel facility, auto return to homelanding, fireman evacuation operation, earthquake operation, door open/closeoperation from COP etc. The system can record information for minimum 30latest faults, with real-time clock management and handheld keypad with LCDscreen for view and setting of parameters. The control panel duly wired withproper size & strength, copper wire for power & control circuit, with provisionfor addition of floor/control card & allied accessories control panel havingenclosure of 1.5mm CRCA sheet with powder coating with IP54 Protection class.· ARD complete with necessary SMF VRLA batteries.· Fireman controller having fireman switch at fire Landing.· CCTV surveillance system comprises of 2 nos minimum 2.0 MP FHD IP based vandal proof Dome camera in lift car & in LMR/inside lift shaft top aimed on Lift machinery & controller with NVR kept in LMR/FCC with HDR data backup min. 90 days with min. 18” FHD TV monitor, to be kept in FCC/LMR as directed by Engineer In Charge.· Lift Machine of Gearless PMSM of suitable kW with duty cycle of minimum 120 starts/hr (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory), with Traction pulley, OSG, electromagnetic brakes, entire assembly mounted on adequate size girders duly fixed on LMR floor/ shaft walls complete with main/diverter traction sheaves, suspension wire ropes/belts of adequate size & strength.· Other mechanical parts such as 'T' section adequate size guide rails for car & counter weight with brackets fasteners, counter weight frame with necessary blocks, buffers with necessary support arrangement, MS pit ladder etc. erected with necessary steel work.· Minor civil work such as alteration work if any necessary for erection of landing door frames and it's accessories e.g. sill, header, hole pass etc complete with plaster finish, civil work for erection buffers, erection of lift machinery, adequate size core cuts if required & scaffolding for erecting guide rails, providing and fixing steel girders/RCC work having adequate strength for mounting and hoisting lift machine etc. complete as per specification no. LFT.· General: - Job includes entire procedure of obtaining all necessary erection permissions & "License to Work the Lift" from Electrical Inspector(Lifts) with submission to the Engineer In Charge.· The above rate includes Fully Comprehensive AMC for one year from the date of commissioning.

4

-

-

... More
SITC of Electric Traction Passenger Lift with· Rated capacity :- 8 Passenger/544Kg· Floors :- G+3 floor (4 Stops/4 Landings)· Travel :- 3 to 4.2 mtrs· Location of Lift Machine:- MR/MRL· Rated speed :- 1.0 mps VS· Car/Landing door clear opening of 800 mm wide x 2000 mm high· Clear Car size of ......mm wide x ......mm deep x 2250mm high· Lift shaft available having clear size of 1900 mm wide x 1900 mm deep, ......mm Pit depth, ………mm Overhead.· Doors type :- COPO/TOPO Doors with frame made from SS 304 gradesolid(non-cladded) sheet of 1.5mm thick in hairline finish for car and all landingdoors with SS door architraves/frames The lift doors shall have minimum 1hour fire rating (with submission of necessary valid test certificate issuedby NABL accredited or Independent test laboratory).· Lift car enclosure made from SS 304 grade solid (non-cladded) sheet of1.5mm, thick with hairline finish with frame made from MS girders, bracing ofadequate size with minimum safety factor of 5, with Toe Guard Apron, withnecessary false ceiling with adequate LED lights, blower/fan for ventilation & SSchequered plate flooring, handrails, mirror, emergency light etc. The lift carinterior design shall be done as per the directions of engineer in charge.· COP with SS face plate having metallic push buttons with Braille code &luminous indicator around button with FPI, scrolling UP/DN LED indicator &with / without attendant key switch, OWD with audio-visual alarm, VAS inMarathi, Hindi & English with intercom system with telephone instrument in Liftcar, LMR & FCC/ground floor.· LOP with SS face plate having recess/surface push button box for alllandings with scrolling UP/DN LED indicator having metallic push buttons withBraille code & luminous indicator around button with CPI, Lift car arrival & nexttravel direction audio-visual indication at all landings.· Lift controller based on microprocessor/ PLC with VVVF Drive havingclosed loop control system, with IBMS compatible having necessary port. Thecontroller shall have necessary protections such as overcurrent, overvoltage, overspeed, overheat for all devices including lift motor and travel directionprotection, protection for phase loss at input or output etc. various operationmodes such as maintenance, change direction by attendant, full load bypass, VIPcall operation, self levelling operation, call cancel facility, auto return to homelanding, fireman evacuation operation, earthquake operation, door open/closeoperation from COP etc. The system can record information for minimum 30latest faults, with real-time clock management and handheld keypad with LCDscreen for view and setting of parameters. The control panel duly wired withproper size & strength, copper wire for power & control circuit, with provisionfor addition of floor/control card & allied accessories control panel havingenclosure of 1.5mm CRCA sheet with powder coating with IP54 Protection class.· ARD complete with necessary SMF VRLA batteries.· Fireman controller having fireman switch at fire Landing.· CCTV surveillance system comprises of 2 nos minimum 2.0 MP FHD IP based vandal proof Dome camera in lift car & in LMR/inside lift shaft top aimed on Lift machinery & controller with NVR kept in LMR/FCC with HDR data backup min. 90 days with min. 18” FHD TV monitor, to be kept in FCC/LMR as directed by Engineer In Charge.· Lift Machine of Gearless PMSM of suitable kW with duty cycle of minimum 120 starts/hr (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory), with Traction pulley, OSG, electromagnetic brakes, entire assembly mounted on adequate size girders duly fixed on LMR floor/ shaft walls complete with main/diverter traction sheaves, suspension wire ropes/belts of adequate size & strength.· Other mechanical parts such as 'T' section adequate size guide rails for car & counter weight with brackets fasteners, counter weight frame with necessary blocks, buffers with necessary support arrangement, MS pit ladder etc. erected with necessary steel work.· Minor civil work such as alteration work if any necessary for erection of landing door frames and it's accessories e.g. sill, header, hole pass etc complete with plaster finish, civil work for erection buffers, erection of lift machinery, adequate size core cuts if required & scaffolding for erecting guide rails, providing and fixing steel girders/RCC work having adequate strength for mounting and hoisting lift machine etc. complete as per specification no. LFT.· General: - Job includes entire procedure of obtaining all necessary erection permissions & "License to Work the Lift" from Electrical Inspector(Lifts) with submission to the Engineer In Charge.· The above rate includes Fully Comprehensive AMC for one year from the date of commissioning.

1

-

-

... More
SITC of Electric Traction Passenger Lift with · Rated capacity :- 10 Passenger/680Kg· Floors :- G+2 floor (3 Stops/3 Landings)· Travel :- 3 to 4.2 mtrs· Location of Lift Machine:- MR/MRL· Rated speed :- 1.0mps VS· Car/Landing door clear opening of 800 mm wide x 2000 mm high· Clear Car size of 1900 mm wide x 2100 mm deep x 2250mm high· Lift shaft available having clear size of ......mm wide x ......mm deep,......mm Pit depth, ………mm Overhead.· Doors type :- COPO/TOPO Doors with frame made from SS 304 gradesolid(non-cladded) sheet of 1.5mm thick in hairline finish for car and all landingdoors with SS door architraves/frames The lift doors shall have minimum 1hour fire rating (with submission of necessary valid test certificate issuedby NABL accredited or Independent test laboratory).· Lift car enclosure made from SS 304 grade solid (non-cladded) sheet of1.5mm, thick with hairline finish with frame made from MS girders, bracing ofadequate size with minimum safety factor of 5, with Toe Guard Apron, withnecessary false ceiling with adequate LED lights, blower/fan for ventilation & SSchequered plate flooring, handrails, mirror, emergency light etc. The lift carinterior design shall be done as per the directions of engineer in charge.· COP with SS face plate having metallic push buttons with Braille code &luminous indicator around button with FPI, scrolling UP/DN LED indicator &with / without attendant key switch, OWD with audio-visual alarm, VAS inMarathi, Hindi & English with intercom system with telephone instrument in Liftcar, LMR & FCC/ground floor.· LOP with SS face plate having recess/surface push button box for alllandings with scrolling UP/DN LED indicator having metallic push buttons withBraille code & luminous indicator around button with CPI, Lift car arrival & nexttravel direction audio-visual indication at all landings.· Lift controller based on microprocessor/ PLC with VVVF Drive havingclosed loop control system, with IBMS compatible having necessary port. Thecontroller shall have necessary protections such as overcurrent, overvoltage, overspeed, overheat for all devices including lift motor and travel directionprotection, protection for phase loss at input or output etc. various operationmodes such as maintenance, change direction by attendant, full load bypass, VIPcall operation, self levelling operation, call cancel facility, auto return to homelanding, fireman evacuation operation, earthquake operation, door open/closeoperation from COP etc. The system can record information for minimum 30latest faults, with real-time clock management and handheld keypad with LCDscreen for view and setting of parameters. The control panel duly wired withproper size & strength, copper wire for power & control circuit, with provisionfor addition of floor/control card & allied accessories control panel havingenclosure of 1.5mm CRCA sheet with powder coating with IP54 Protection class.· ARD complete with necessary SMF VRLA batteries.· Fireman controller having fireman switch at fire Landing.· CCTV surveillance system comprises of 2 nos minimum 2.0 MP FHD IP based vandal proof Dome camera in lift car & in LMR/inside lift shaft top aimed on Lift machinery & controller with NVR kept in LMR/FCC with HDR data backup min. 90 days with min. 18” FHD TV monitor, to be kept in FCC/LMR as directed by Engineer In Charge.· Lift Machine of Gearless PMSM of suitable kW with duty cycle of minimum 120 starts/hr (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory), with Traction pulley, OSG, electromagnetic brakes, entire assembly mounted on adequate size girders duly fixed on LMR floor/ shaft walls complete with main/diverter traction sheaves, suspension wire ropes/belts of adequate size & strength.· Other mechanical parts such as 'T' section adequate size guide rails for car & counter weight with brackets fasteners, counter weight frame with necessary blocks, buffers with necessary support arrangement, MS pit ladder etc. erected with necessary steel work.· Minor civil work such as alteration work if any necessary for erection of landing door frames and it's accessories e.g. sill, header, hole pass etc complete with plaster finish, civil work for erection buffers, erection of lift machinery, adequate size core cuts if required & scaffolding for erecting guide rails, providing and fixing steel girders/RCC work having adequate strength for mounting and hoisting lift machine etc. complete as per specification no. LFT.· General: - Job includes entire procedure of obtaining all necessary erection permissions & "License to Work the Lift" from Electrical Inspector(Lifts) with submission to the Engineer In Charge.· The above rate includes Fully Comprehensive AMC for one year from the date of commissioning.· Rated capacity :- 10 Passenger/680Kg· Floors :- G+2 floor (3 Stops/3 Landings)· Travel :- 3 to 4.2 mtrs· Location of Lift Machine:- MR/MRL· Rated speed :- 1.0mps VS· Car/Landing door clear opening of 800 mm wide x 2000 mm high· Clear Car size of 1900 mm wide x 2100 mm deep x 2250mm high· Lift shaft available having clear size of ......mm wide x ......mm deep,......mm Pit depth, ………mm Overhead.· Doors type :- COPO/TOPO Doors with frame made from SS 304 gradesolid(non-cladded) sheet of 1.5mm thick in hairline finish for car and all landingdoors with SS door architraves/frames The lift doors shall have minimum 1hour fire rating (with submission of necessary valid test certificate issuedby NABL accredited or Independent test laboratory).· Lift car enclosure made from SS 304 grade solid (non-cladded) sheet of1.5mm, thick with hairline finish with frame made from MS girders, bracing ofadequate size with minimum safety factor of 5, with Toe Guard Apron, withnecessary false ceiling with adequate LED lights, blower/fan for ventilation & SSchequered plate flooring, handrails, mirror, emergency light etc. The lift carinterior design shall be done as per the directions of engineer in charge.· COP with SS face plate having metallic push buttons with Braille code &luminous indicator around button with FPI, scrolling UP/DN LED indicator &with / without attendant key switch, OWD with audio-visual alarm, VAS inMarathi, Hindi & English with intercom system with telephone instrument in Liftcar, LMR & FCC/ground floor.· LOP with SS face plate having recess/surface push button box for alllandings with scrolling UP/DN LED indicator having metallic push buttons withBraille code & luminous indicator around button with CPI, Lift car arrival & nexttravel direction audio-visual indication at all landings.· Lift controller based on microprocessor/ PLC with VVVF Drive havingclosed loop control system, with IBMS compatible having necessary port. Thecontroller shall have necessary protections such as overcurrent, overvoltage, overspeed, overheat for all devices including lift motor and travel directionprotection, protection for phase loss at input or output etc. various operationmodes such as maintenance, change direction by attendant, full load bypass, VIPcall operation, self levelling operation, call cancel facility, auto return to homelanding, fireman evacuation operation, earthquake operation, door open/closeoperation from COP etc. The system can record information for minimum 30latest faults, with real-time clock management and handheld keypad with LCDscreen for view and setting of parameters. The control panel duly wired withproper size & strength, copper wire for power & control circuit, with provisionfor addition of floor/control card & allied accessories control panel havingenclosure of 1.5mm CRCA sheet with powder coating with IP54 Protection class.· ARD complete with necessary SMF VRLA batteries.· Fireman controller having fireman switch at fire Landing.· CCTV surveillance system comprises of 2 nos minimum 2.0 MP FHD IP based vandal proof Dome camera in lift car & in LMR/inside lift shaft top aimed on Lift machinery & controller with NVR kept in LMR/FCC with HDR data backup min. 90 days with min. 18” FHD TV monitor, to be kept in FCC/LMR as directed by Engineer In Charge.· Lift Machine of Gearless PMSM of suitable kW with duty cycle of minimum 120 starts/hr (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory), with Traction pulley, OSG, electromagnetic brakes, entire assembly mounted on adequate size girders duly fixed on LMR floor/ shaft walls complete with main/diverter traction sheaves, suspension wire ropes/belts of adequate size & strength.· Other mechanical parts such as 'T' section adequate size guide rails for car & counter weight with brackets fasteners, counter weight frame with necessary blocks, buffers with necessary support arrangement, MS pit ladder etc. erected with necessary steel work.· Minor civil work such as alteration work if any necessary for erection of landing door frames and it's accessories e.g. sill, header, hole pass etc complete with plaster finish, civil work for erection buffers, erection of lift machinery, adequate size core cuts if required & scaffolding for erecting guide rails, providing and fixing steel girders/RCC work having adequate strength for mounting and hoisting lift machine etc. complete as per specification no. LFT.· General: - Job includes entire procedure of obtaining all necessary erection permissions & "License to Work the Lift" from Electrical Inspector(Lifts) with submission to the Engineer In Charge.· The above rate includes Fully Comprehensive AMC for one year from the date of commissioning.

5

-

-

... More
SITC of Electric Traction Passenger Lift with · Rated capacity :- 10 Passenger/680Kg· Floors :- G+3 floor (4 Stops/4 Landings)· Travel :- 3 to 4.2 mtrs· Location of Lift Machine:- MR/MRL· Rated speed :- 1.0mps VS· Car/Landing door clear opening of 800 mm wide x 2000 mm high· Clear Car size of 1900 mm wide x 2100 mm deep x 2250mm high· Lift shaft available having clear size of ......mm wide x ......mm deep,......mm Pit depth, ………mm Overhead.· Doors type :- COPO/TOPO Doors with frame made from SS 304 gradesolid(non-cladded) sheet of 1.5mm thick in hairline finish for car and all landingdoors with SS door architraves/frames The lift doors shall have minimum 1hour fire rating (with submission of necessary valid test certificate issuedby NABL accredited or Independent test laboratory).· Lift car enclosure made from SS 304 grade solid (non-cladded) sheet of1.5mm, thick with hairline finish with frame made from MS girders, bracing ofadequate size with minimum safety factor of 5, with Toe Guard Apron, withnecessary false ceiling with adequate LED lights, blower/fan for ventilation & SSchequered plate flooring, handrails, mirror, emergency light etc. The lift carinterior design shall be done as per the directions of engineer in charge.· COP with SS face plate having metallic push buttons with Braille code &luminous indicator around button with FPI, scrolling UP/DN LED indicator &with / without attendant key switch, OWD with audio-visual alarm, VAS inMarathi, Hindi & English with intercom system with telephone instrument in Liftcar, LMR & FCC/ground floor.· LOP with SS face plate having recess/surface push button box for alllandings with scrolling UP/DN LED indicator having metallic push buttons withBraille code & luminous indicator around button with CPI, Lift car arrival & nexttravel direction audio-visual indication at all landings.· Lift controller based on microprocessor/ PLC with VVVF Drive havingclosed loop control system, with IBMS compatible having necessary port. Thecontroller shall have necessary protections such as overcurrent, overvoltage, overspeed, overheat for all devices including lift motor and travel directionprotection, protection for phase loss at input or output etc. various operationmodes such as maintenance, change direction by attendant, full load bypass, VIPcall operation, self levelling operation, call cancel facility, auto return to homelanding, fireman evacuation operation, earthquake operation, door open/closeoperation from COP etc. The system can record information for minimum 30latest faults, with real-time clock management and handheld keypad with LCDscreen for view and setting of parameters. The control panel duly wired withproper size & strength, copper wire for power & control circuit, with provisionfor addition of floor/control card & allied accessories control panel havingenclosure of 1.5mm CRCA sheet with powder coating with IP54 Protection class.· ARD complete with necessary SMF VRLA batteries.· Fireman controller having fireman switch at fire Landing.· CCTV surveillance system comprises of 2 nos minimum 2.0 MP FHD IP based vandal proof Dome camera in lift car & in LMR/inside lift shaft top aimed on Lift machinery & controller with NVR kept in LMR/FCC with HDR data backup min. 90 days with min. 18” FHD TV monitor, to be kept in FCC/LMR as directed by Engineer In Charge.· Lift Machine of Gearless PMSM of suitable kW with duty cycle of minimum 120 starts/hr (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory), with Traction pulley, OSG, electromagnetic brakes, entire assembly mounted on adequate size girders duly fixed on LMR floor/ shaft walls complete with main/diverter traction sheaves, suspension wire ropes/belts of adequate size & strength.· Other mechanical parts such as 'T' section adequate size guide rails for car & counter weight with brackets fasteners, counter weight frame with necessary blocks, buffers with necessary support arrangement, MS pit ladder etc. erected with necessary steel work.· Minor civil work such as alteration work if any necessary for erection of landing door frames and it's accessories e.g. sill, header, hole pass etc complete with plaster finish, civil work for erection buffers, erection of lift machinery, adequate size core cuts if required & scaffolding for erecting guide rails, providing and fixing steel girders/RCC work having adequate strength for mounting and hoisting lift machine etc. complete as per specification no. LFT.· General: - Job includes entire procedure of obtaining all necessary erection permissions & "License to Work the Lift" from Electrical Inspector(Lifts) with submission to the Engineer In Charge.· The above rate includes Fully Comprehensive AMC for one year from the date of commissioning.

1

-

-

... More
SITC of Electric Traction Passenger Lift with · Rated capacity :- 13 Passenger/884Kg· Floors :- G+1 floor (2 Stops/2 Landings)· Travel :- 3 to 4.2 mtrs.· Location of Lift Machine:- MR/MRL· Rated speed :- 1.0mps VS· Car/Landing door clear opening of 900/1000 mm wide x 2000 mmhigh· Clear Car size of ......mm wide x ......mm deep x 2250mm high· Lift shaft available having clear size of 1900 mm wide x 2500 mm deep, ......mm Pit depth, ………mm Overhead.Doors type :- COPO/TOPO Doors with frame made from SS 304 gradesolid(non-cladded) sheet of 1.5mm thick in hairline finish for car and all landingdoors with SS door architraves/frames The lift doors shall have minimum 1hour fire rating (with submission of necessary valid test certificate issuedby NABL accredited or Independent test laboratory).· Lift car enclosure made from SS 304 grade solid (non-cladded) sheet of1.5mm, thick with hairline finish with frame made from MS girders, bracing ofadequate size with minimum safety factor of 5, with Toe Guard Apron, withnecessary false ceiling with adequate LED lights, blower/fan for ventilation & SSchequered plate flooring, handrails, mirror, emergency light etc. The lift carinterior design shall be done as per the directions of engineer in charge.· COP with SS face plate having metallic push buttons with Braille code &luminous indicator around button with FPI, scrolling UP/DN LED indicator &with / without attendant key switch, OWD with audio-visual alarm, VAS inMarathi, Hindi & English with intercom system with telephone instrument in Liftcar, LMR & FCC/ground floor.· LOP with SS face plate having recess/surface push button box for alllandings with scrolling UP/DN LED indicator having metallic push buttons withBraille code & luminous indicator around button with CPI, Lift car arrival & nexttravel direction audio-visual indication at all landings.· Lift controller based on microprocessor/ PLC with VVVF Drive havingclosed loop control system, with IBMS compatible having necessary port. Thecontroller shall have necessary protections such as overcurrent, overvoltage, overspeed, overheat for all devices including lift motor and travel directionprotection, protection for phase loss at input or output etc. various operationmodes such as maintenance, change direction by attendant, full load bypass, VIPcall operation, self levelling operation, call cancel facility, auto return to homelanding, fireman evacuation operation, earthquake operation, door open/closeoperation from COP etc. The system can record information for minimum 30latest faults, with real-time clock management and handheld keypad with LCDscreen for view and setting of parameters, The control panel duly wired withproper size & strength, copper wire for power & control circuit, with provisionfor addition of floor/control card & allied accessories control panel havingenclosure of 1.5mm CRCA sheet with powder coating with IP54 Protection class.· ARD complete with necessary SMF VRLA batteries.· Fireman controller having fireman switch at fire Landing.· CCTV surveillance system comprises of 2 nos minimum 2.0MP FHD IPbased vandal proof Dome camera in lift car & in LMR/inside lift shaft top aimedon Lift machinery & controller with NVR kept in LMR/FCC with HDR databackup for min. 90 days with min. 18” FHD TV monitor, to be kept inFCC/LMR as directed by Engineer In Charge.· Lift Machine of Gearless PMSM of suitable kW with duty cycle ofminimum 120 starts/hr (with submission of necessary valid test certificate issuedby NABL accredited or Independent test laboratory), with Traction pulley, OSG,electromagnetic brakes, entire assembly mounted on adequate size girders dulyfixed on LMR floor/ shaft walls complete with main/diverter traction sheaves,suspension wire ropes/belts of adequate size & strength.· Other mechanical parts such as 'T' section adequate size guide rails for car &counter weight with brackets fasteners, counter weight frame with necessaryblocks, buffers with necessary support arrangement, MS pit ladder etc. erectedwith necessary steel work.· Minor civil work such as alteration work if any necessary for erection oflanding door frames and it's accessories e.g. sill, header, hole pass etc completewith plaster finish, civil work for erection buffers, erection of lift machinery,adequate size core cuts if required & scaffolding for erecting guide rails, providingand fixing steel girders/RCC work having adequate strength for mounting andhoisting lift machine etc. complete as per specification no. LFT.· General: - Job includes entire procedure of obtaining all necessary erection permissions & "License to Work the Lift" from Electrical Inspector(Lifts) with submission to the Engineer In Charge.· The above rate includes Fully Comprehensive AMC for one year from the date of commissioning.· Rated capacity :- 13 Passenger/884Kg· Floors :- G+1 floor (2 Stops/2 Landings)· Travel :- 3 to 4.2 mtrs.· Location of Lift Machine:- MR/MRL· Rated speed :- 1.0mps VS· Car/Landing door clear opening of 900/1000 mm wide x 2000 mmhigh· Clear Car size of ......mm wide x ......mm deep x 2250mm high· Lift shaft available having clear size of 1900 mm wide x 2500 mm deep, ......mm Pit depth, ………mm Overhead.Doors type :- COPO/TOPO Doors with frame made from SS 304 gradesolid(non-cladded) sheet of 1.5mm thick in hairline finish for car and all landingdoors with SS door architraves/frames The lift doors shall have minimum 1hour fire rating (with submission of necessary valid test certificate issuedby NABL accredited or Independent test laboratory).· Lift car enclosure made from SS 304 grade solid (non-cladded) sheet of1.5mm, thick with hairline finish with frame made from MS girders, bracing ofadequate size with minimum safety factor of 5, with Toe Guard Apron, withnecessary false ceiling with adequate LED lights, blower/fan for ventilation & SSchequered plate flooring, handrails, mirror, emergency light etc. The lift carinterior design shall be done as per the directions of engineer in charge.· COP with SS face plate having metallic push buttons with Braille code &luminous indicator around button with FPI, scrolling UP/DN LED indicator &with / without attendant key switch, OWD with audio-visual alarm, VAS inMarathi, Hindi & English with intercom system with telephone instrument in Liftcar, LMR & FCC/ground floor.· LOP with SS face plate having recess/surface push button box for alllandings with scrolling UP/DN LED indicator having metallic push buttons withBraille code & luminous indicator around button with CPI, Lift car arrival & nexttravel direction audio-visual indication at all landings.· Lift controller based on microprocessor/ PLC with VVVF Drive havingclosed loop control system, with IBMS compatible having necessary port. Thecontroller shall have necessary protections such as overcurrent, overvoltage, overspeed, overheat for all devices including lift motor and travel directionprotection, protection for phase loss at input or output etc. various operationmodes such as maintenance, change direction by attendant, full load bypass, VIPcall operation, self levelling operation, call cancel facility, auto return to homelanding, fireman evacuation operation, earthquake operation, door open/closeoperation from COP etc. The system can record information for minimum 30latest faults, with real-time clock management and handheld keypad with LCDscreen for view and setting of parameters, The control panel duly wired withproper size & strength, copper wire for power & control circuit, with provisionfor addition of floor/control card & allied accessories control panel havingenclosure of 1.5mm CRCA sheet with powder coating with IP54 Protection class.· ARD complete with necessary SMF VRLA batteries.· Fireman controller having fireman switch at fire Landing.· CCTV surveillance system comprises of 2 nos minimum 2.0MP FHD IPbased vandal proof Dome camera in lift car & in LMR/inside lift shaft top aimedon Lift machinery & controller with NVR kept in LMR/FCC with HDR databackup for min. 90 days with min. 18” FHD TV monitor, to be kept inFCC/LMR as directed by Engineer In Charge.· Lift Machine of Gearless PMSM of suitable kW with duty cycle ofminimum 120 starts/hr (with submission of necessary valid test certificate issuedby NABL accredited or Independent test laboratory), with Traction pulley, OSG,electromagnetic brakes, entire assembly mounted on adequate size girders dulyfixed on LMR floor/ shaft walls complete with main/diverter traction sheaves,suspension wire ropes/belts of adequate size & strength.· Other mechanical parts such as 'T' section adequate size guide rails for car &counter weight with brackets fasteners, counter weight frame with necessaryblocks, buffers with necessary support arrangement, MS pit ladder etc. erectedwith necessary steel work.· Minor civil work such as alteration work if any necessary for erection oflanding door frames and it's accessories e.g. sill, header, hole pass etc completewith plaster finish, civil work for erection buffers, erection of lift machinery,adequate size core cuts if required & scaffolding for erecting guide rails, providingand fixing steel girders/RCC work having adequate strength for mounting andhoisting lift machine etc. complete as per specification no. LFT.· General: - Job includes entire procedure of obtaining all necessary erection permissions & "License to Work the Lift" from Electrical Inspector(Lifts) with submission to the Engineer In Charge.· The above rate includes Fully Comprehensive AMC for one year from the date of commissioning.

1

-

-

... More
SITC of Electric Traction Passenger Lift with · Rated capacity :- 16 Passenger/1088Kg· Floors :- G+2 floor (3 Stops/3 Landings)· Travel :- 3 to 4.2 mtrs.· Location of Lift Machine:- MR/MRL· Rated speed :- 1.0mps VS· Car/Landing door clear opening of 900/1000 mm wide x 2000 mmhigh· Clear Car size of ......mm wide x ......mm deep x 2250mm high· Lift shaft available having clear size of 1900 mm wide x 2500 mm deep, ......mm Pit depth, ………mm Overhead.Doors type :- COPO/TOPO Doors with frame made from SS 304 gradesolid(non-cladded) sheet of 1.5mm thick in hairline finish for car and all landingdoors with SS door architraves/frames The lift doors shall have minimum 1hour fire rating (with submission of necessary valid test certificate issuedby NABL accredited or Independent test laboratory).· Lift car enclosure made from SS 304 grade solid (non-cladded) sheet of1.5mm, thick with hairline finish with frame made from MS girders, bracing ofadequate size with minimum safety factor of 5, with Toe Guard Apron, withnecessary false ceiling with adequate LED lights, blower/fan for ventilation & SSchequered plate flooring, handrails, mirror, emergency light etc. The lift carinterior design shall be done as per the directions of engineer in charge.· COP with SS face plate having metallic push buttons with Braille code &luminous indicator around button with FPI, scrolling UP/DN LED indicator &with / without attendant key switch, OWD with audio-visual alarm, VAS inMarathi, Hindi & English with intercom system with telephone instrument in Liftcar, LMR & FCC/ground floor.· LOP with SS face plate having recess/surface push button box for alllandings with scrolling UP/DN LED indicator having metallic push buttons withBraille code & luminous indicator around button with CPI, Lift car arrival & nexttravel direction audio-visual indication at all landings.· Lift controller based on microprocessor/ PLC with VVVF Drive havingclosed loop control system, with IBMS compatible having necessary port. Thecontroller shall have necessary protections such as overcurrent, overvoltage, overspeed, overheat for all devices including lift motor and travel directionprotection, protection for phase loss at input or output etc. various operationmodes such as maintenance, change direction by attendant, full load bypass, VIPcall operation, self levelling operation, call cancel facility, auto return to homelanding, fireman evacuation operation, earthquake operation, door open/closeoperation from COP etc. The system can record information for minimum 30latest faults, with real-time clock management and handheld keypad with LCDscreen for view and setting of parameters, The control panel duly wired withproper size & strength, copper wire for power & control circuit, with provisionfor addition of floor/control card & allied accessories control panel havingenclosure of 1.5mm CRCA sheet with powder coating with IP54 Protection class.· ARD complete with necessary SMF VRLA batteries.· Fireman controller having fireman switch at fire Landing.· CCTV surveillance system comprises of 2 nos minimum 2.0MP FHD IPbased vandal proof Dome camera in lift car & in LMR/inside lift shaft top aimedon Lift machinery & controller with NVR kept in LMR/FCC with HDR databackup for min. 90 days with min. 18” FHD TV monitor, to be kept inFCC/LMR as directed by Engineer In Charge.· Lift Machine of Gearless PMSM of suitable kW with duty cycle ofminimum 120 starts/hr (with submission of necessary valid test certificate issuedby NABL accredited or Independent test laboratory), with Traction pulley, OSG,electromagnetic brakes, entire assembly mounted on adequate size girders dulyfixed on LMR floor/ shaft walls complete with main/diverter traction sheaves,suspension wire ropes/belts of adequate size & strength.· Other mechanical parts such as 'T' section adequate size guide rails for car &counter weight with brackets fasteners, counter weight frame with necessaryblocks, buffers with necessary support arrangement, MS pit ladder etc. erectedwith necessary steel work.· Minor civil work such as alteration work if any necessary for erection oflanding door frames and it's accessories e.g. sill, header, hole pass etc completewith plaster finish, civil work for erection buffers, erection of lift machinery,adequate size core cuts if required & scaffolding for erecting guide rails, providingand fixing steel girders/RCC work having adequate strength for mounting andhoisting lift machine etc. complete as per specification no. LFT.· General: - Job includes entire procedure of obtaining all necessary erection permissions & "License to Work the Lift" from Electrical Inspector(Lifts) with submission to the Engineer In Charge.· The above rate includes Fully Comprehensive AMC for one year from the date of commissioning.

8

-

-

... More
SITC of Electric Traction Passenger Lift with · Rated capacity :- 16 Passenger/1088Kg· Floors :- G+4 floor (5 Stops/5 Landings)· Travel :- 3 to 4.2 mtrs.· Location of Lift Machine:- MR/MRL· Rated speed :- 1.0mps VS· Car/Landing door clear opening of 900/1000 mm wide x 2000 mmhigh· Clear Car size of ......mm wide x ......mm deep x 2250mm high· Lift shaft available having clear size of 1900 mm wide x 2500 mm deep, ......mm Pit depth, ………mm Overhead.Doors type :- COPO/TOPO Doors with frame made from SS 304 gradesolid(non-cladded) sheet of 1.5mm thick in hairline finish for car and all landingdoors with SS door architraves/frames The lift doors shall have minimum 1hour fire rating (with submission of necessary valid test certificate issuedby NABL accredited or Independent test laboratory).· Lift car enclosure made from SS 304 grade solid (non-cladded) sheet of1.5mm, thick with hairline finish with frame made from MS girders, bracing ofadequate size with minimum safety factor of 5, with Toe Guard Apron, withnecessary false ceiling with adequate LED lights, blower/fan for ventilation & SSchequered plate flooring, handrails, mirror, emergency light etc. The lift carinterior design shall be done as per the directions of engineer in charge.· COP with SS face plate having metallic push buttons with Braille code &luminous indicator around button with FPI, scrolling UP/DN LED indicator &with / without attendant key switch, OWD with audio-visual alarm, VAS inMarathi, Hindi & English with intercom system with telephone instrument in Liftcar, LMR & FCC/ground floor.· LOP with SS face plate having recess/surface push button box for alllandings with scrolling UP/DN LED indicator having metallic push buttons withBraille code & luminous indicator around button with CPI, Lift car arrival & nexttravel direction audio-visual indication at all landings.· Lift controller based on microprocessor/ PLC with VVVF Drive havingclosed loop control system, with IBMS compatible having necessary port. Thecontroller shall have necessary protections such as overcurrent, overvoltage, overspeed, overheat for all devices including lift motor and travel directionprotection, protection for phase loss at input or output etc. various operationmodes such as maintenance, change direction by attendant, full load bypass, VIPcall operation, self levelling operation, call cancel facility, auto return to homelanding, fireman evacuation operation, earthquake operation, door open/closeoperation from COP etc. The system can record information for minimum 30latest faults, with real-time clock management and handheld keypad with LCDscreen for view and setting of parameters, The control panel duly wired withproper size & strength, copper wire for power & control circuit, with provisionfor addition of floor/control card & allied accessories control panel havingenclosure of 1.5mm CRCA sheet with powder coating with IP54 Protection class.· ARD complete with necessary SMF VRLA batteries.· Fireman controller having fireman switch at fire Landing.· CCTV surveillance system comprises of 2 nos minimum 2.0MP FHD IPbased vandal proof Dome camera in lift car & in LMR/inside lift shaft top aimedon Lift machinery & controller with NVR kept in LMR/FCC with HDR databackup for min. 90 days with min. 18” FHD TV monitor, to be kept inFCC/LMR as directed by Engineer In Charge.· Lift Machine of Gearless PMSM of suitable kW with duty cycle ofminimum 120 starts/hr (with submission of necessary valid test certificate issuedby NABL accredited or Independent test laboratory), with Traction pulley, OSG,electromagnetic brakes, entire assembly mounted on adequate size girders dulyfixed on LMR floor/ shaft walls complete with main/diverter traction sheaves,suspension wire ropes/belts of adequate size & strength.· Other mechanical parts such as 'T' section adequate size guide rails for car &counter weight with brackets fasteners, counter weight frame with necessaryblocks, buffers with necessary support arrangement, MS pit ladder etc. erectedwith necessary steel work.· Minor civil work such as alteration work if any necessary for erection oflanding door frames and it's accessories e.g. sill, header, hole pass etc completewith plaster finish, civil work for erection buffers, erection of lift machinery,adequate size core cuts if required & scaffolding for erecting guide rails, providingand fixing steel girders/RCC work having adequate strength for mounting andhoisting lift machine etc. complete as per specification no. LFT.· General: - Job includes entire procedure of obtaining all necessary erection permissions & "License to Work the Lift" from Electrical Inspector(Lifts) with submission to the Engineer In Charge.· The above rate includes Fully Comprehensive AMC for one year from the date of commissioning.

2

-

-

... More
SITC of Electric Traction Passenger Lift with · Rated capacity :- 20 Passenger/1088Kg· Floors :- G+3 floor (4 Stops/4 Landings)· Travel :- 3 to 4.2 mtrs.· Location of Lift Machine:- MR/MRL· Rated speed :- 1.0mps VS· Car/Landing door clear opening of 900/1000 mm wide x 2000 mmhigh· Clear Car size of ......mm wide x ......mm deep x 2250mm high· Lift shaft available having clear size of 1900 mm wide x 2500 mm deep, ......mm Pit depth, ………mm Overhead.Doors type :- COPO/TOPO Doors with frame made from SS 304 gradesolid(non-cladded) sheet of 1.5mm thick in hairline finish for car and all landingdoors with SS door architraves/frames The lift doors shall have minimum 1hour fire rating (with submission of necessary valid test certificate issuedby NABL accredited or Independent test laboratory).· Lift car enclosure made from SS 304 grade solid (non-cladded) sheet of1.5mm, thick with hairline finish with frame made from MS girders, bracing ofadequate size with minimum safety factor of 5, with Toe Guard Apron, withnecessary false ceiling with adequate LED lights, blower/fan for ventilation & SSchequered plate flooring, handrails, mirror, emergency light etc. The lift carinterior design shall be done as per the directions of engineer in charge.· COP with SS face plate having metallic push buttons with Braille code &luminous indicator around button with FPI, scrolling UP/DN LED indicator &with / without attendant key switch, OWD with audio-visual alarm, VAS inMarathi, Hindi & English with intercom system with telephone instrument in Liftcar, LMR & FCC/ground floor.· LOP with SS face plate having recess/surface push button box for alllandings with scrolling UP/DN LED indicator having metallic push buttons withBraille code & luminous indicator around button with CPI, Lift car arrival & nexttravel direction audio-visual indication at all landings.· Lift controller based on microprocessor/ PLC with VVVF Drive havingclosed loop control system, with IBMS compatible having necessary port. Thecontroller shall have necessary protections such as overcurrent, overvoltage, overspeed, overheat for all devices including lift motor and travel directionprotection, protection for phase loss at input or output etc. various operationmodes such as maintenance, change direction by attendant, full load bypass, VIPcall operation, self levelling operation, call cancel facility, auto return to homelanding, fireman evacuation operation, earthquake operation, door open/closeoperation from COP etc. The system can record information for minimum 30latest faults, with real-time clock management and handheld keypad with LCDscreen for view and setting of parameters, The control panel duly wired withproper size & strength, copper wire for power & control circuit, with provisionfor addition of floor/control card & allied accessories control panel havingenclosure of 1.5mm CRCA sheet with powder coating with IP54 Protection class.· ARD complete with necessary SMF VRLA batteries.· Fireman controller having fireman switch at fire Landing.· CCTV surveillance system comprises of 2 nos minimum 2.0MP FHD IPbased vandal proof Dome camera in lift car & in LMR/inside lift shaft top aimedon Lift machinery & controller with NVR kept in LMR/FCC with HDR databackup for min. 90 days with min. 18” FHD TV monitor, to be kept inFCC/LMR as directed by Engineer In Charge.· Lift Machine of Gearless PMSM of suitable kW with duty cycle ofminimum 120 starts/hr (with submission of necessary valid test certificate issuedby NABL accredited or Independent test laboratory), with Traction pulley, OSG,electromagnetic brakes, entire assembly mounted on adequate size girders dulyfixed on LMR floor/ shaft walls complete with main/diverter traction sheaves,suspension wire ropes/belts of adequate size & strength.· Other mechanical parts such as 'T' section adequate size guide rails for car &counter weight with brackets fasteners, counter weight frame with necessaryblocks, buffers with necessary support arrangement, MS pit ladder etc. erectedwith necessary steel work.· Minor civil work such as alteration work if any necessary for erection oflanding door frames and it's accessories e.g. sill, header, hole pass etc completewith plaster finish, civil work for erection buffers, erection of lift machinery,adequate size core cuts if required & scaffolding for erecting guide rails, providingand fixing steel girders/RCC work having adequate strength for mounting andhoisting lift machine etc. complete as per specification no. LFT.· General: - Job includes entire procedure of obtaining all necessary erection permissions & "License to Work the Lift" from Electrical Inspector(Lifts) with submission to the Engineer In Charge.· The above rate includes Fully Comprehensive AMC for one year from the date of commissioning.

4

-

-

... More
For Lift having 800mm wide x 2000mm high clear entrance in 1.5mm thick SS304 grade solid (non-cladded) landing door [Two panel], this includes allnecessary accessories like LOP's with UP/DN buttons-arrows-indicators,extension of guide rails, shaft wiring with trunking, traveling cables, main hoistingropes/belts, & OSG rope landing doors with all accessories etc. necessary for thenormal safe functioning of lift installation complete.

12

-

-

... More
For Lift having 900mm wide x 2000mm high clear entrance in 1.5mm thick SS304 grade solid(non-cladded) landing door [Two panel], this includes all necessary accessories like LOP's with UP/DN buttons-arrows-indicators, extension of guide rails, shaft wiring with trunking, travelling cables, main hoisting ropes/ belts, & OSG rope landing doors with all accessories etc. necessaryfor the normal safe functioning of lift installation complete.

14

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.