Maharashtra State Infrastructure Development Corporation Tender
Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.
Maharashtra State Infrastructure Development Corporation - MSIDC Tender
Civil And Construction
Building Construction
Electrical and Electronics
Water Storage And Supply
Electrical Works
Eprocure
Opening Date19 Aug 2024
Closing DateCancelled
Tender Amount₹ 43,65,07,101
Costs
EMD
₹ 43,65,071Document Cost
₹ 11,800Tender Fee
₹ 500
Summary
Construction Of 24 New Sub-registrar Offices Across Maharashtra State
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MSIDC_1072251_1Tender No
2024_MSIDC_1072251_1Tender Authority
Maharashtra State Infrastructure Development Corporation ViewPurchaser Address
-Website
http://mahatenders.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
ERANDOL -A
-
-
-
MUKTAINAGAR-A
-
-
-
BODWAD-A
-
-
-
BHUSAWAL-A
-
-
-
JAMNER-A
-
-
-
PAAROLA - A
-
-
-
MOHOL - A
-
-
-
PANDHARPUR-01 - A
-
-
-
PANDHARPUR-02 - A
-
-
-
KARMALA-A
-
-
-
KHULDABAD-A
-
-
-
PATODA-A
-
-
-
SHIRURSHKAR-A
-
-
-
NILANGA-A
-
-
-
UDGIR-A
-
-
-
KANDHAR-A
-
-
-
LOHA-A
-
-
-
Construction of 24 3D precast concrete building structures including casting, supplying, providing and installation at site for Sub Registrar offices at different locations across Maharashtra including following items of work as described in detail in Part-I of Technical specifications of the DTP.
► Building civil work 3D Precast
► Internal electrification, main Panel
► Solar Power generation
► Telephone cables, CCTV system
► Architecture items (internal & external)
► HVAC system ► Internal Fire Fighting works ► Underground water tank & Overhead water tank
The quantum of work required to complete the above item of works which are described in detail at Part-I of technical specifications shall be worked out by the contractor based on the type plans attached with the tender document for reference. All items of work (internal & external items) required for construction shall be complete on the lock and key basis. The contractor is required to put the cost of completing all the above items so as to bring the completeness of a building.
6
-
-
Type B building- 6 units each of area 287 sqm.
-
-
-
AARVI-B
-
-
-
KARANJA-B
-
-
-
BABHULGAON-B
-
-
-
VASMAT-B
-
-
-
PURNA - B
-
-
-
HINGOLI -02 - B
-
-
-
Construction of 24 3D precast concrete building structures including casting, supplying, providing and installation at site for Sub Registrar offices at different locations across Maharashtra including following items of work as described in detail in Part-I of Technical specifications of the DTP.
► Building civil work 3D Precast
► Internal electrification, main Panel
► Solar Power generation
► Telephone cables, CCTV system
► Architecture items (internal & external)
► HVAC system ► Internal Fire Fighting works ► Underground water tank & Overhead water tank
The quantum of work required to complete the above item of works which are described in detail at Part-I of technical specifications shall be worked out by the contractor based on the type plans attached with the tender document for reference. All items of work (internal & external items) required for construction shall be complete on the lock and key basis. The contractor is required to put the cost of completing all the above items so as to bring the completeness of a building.
1
-
-
Type C building- 1 units of each area 425 sqm.
-
-
-
HINGOLI -01 - C
-
-
-
EXTERNAL ELECTRICAL WORKS (FOR INDIVIDUAL SITE QUANTITY REFER ANNEXURE - 1)
-
-
-
Supplying and erecting PVC insulated PVC round sheathed 2.5 sq.mm (50 no. x 0.25 mm dia.) 3 core flexible multi stranded copper Industrial cable for voltage grade up to 1.1 kV (for street light pole fixtrue wiring)
2325
-
-
Supplying and erecting integrated LED street light fitting 60W IP65 & IK08 class having single piece pressure die-cast aluminium housing, having system lumens output of Min. 6600 Lumens, min. efficacy of 110 lumen/W, CRI70, CCT upto 6500K, THD10%, p.f. 0.95, operating range of 140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, including driver complete with 3 Years warranty as per specification No FG-ODF/FLS2.
139
-
-
Supplying and erecting integrated LED Bollard Cylindrical / Cubical shaped 800mm 8W IP65 & IK10 class having extrusion aluminium housing with polycarbonate diffuser, having system lumens output of Min. 800 Lumens, min. efficacy of 100 lumen/W, CRI80, CCT upto 6500K, THD10%, p.f. 0.90, operating range of 140-240V, inbuilt surge protection of 2 kV, Life class of 25,000 Hrs. at L50B50, including driver complete with minimum 2 Year warranty as per specification No FG-ODF/BL.
162
-
-
Supplying, erecting & marking SPMCB 6A to 32A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB (Street Light Pole)
234
-
-
Supplying & erecting 415V, 16A porcelain base neutral link complete erected in provided M.S. box.
234
-
-
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 6 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL (street Light pole to connection cable)
17429
-
-
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 25 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/ALL (stret Light panel suply cable)
4647.2
-
-
Supplying and laying (including excavation of suitable width & depth up to 90 cm) 50 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete.
2325
-
-
Providing & erecting 6 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 130 mm A/F, top 70 mm A/F on provided foundation as per specification no. OH-PL/OPL
165
-
-
Providing and erecting galvanised 1000mm single arm sword type bracket with FRP dome and ball as per specification no. OH-PL/PBKT
165
-
-
Providing and erecting galvanised 1000mm double arm sword type bracket with FRP dome and ball as per specification no. OH-PL/PBKT
165
-
-
Providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm with funnel with a wire mesh for watering and brick masonry block C.l. cover complete with all materials, testing & recording the results as per specification no. EA-EP
26
-
-
Providing pipe type earthing with 40mm. dia. G.I. pipe or 20 mm dia. G.I. Rod complete with all materials testing and recording the results as per specification no.
EA-EP
165
-
-
Making M- 20 grade reinforced cement concrete foundation by considering the safe soil bearing capacity at site as 10 T/sq.m at 1.5 m depth including supply of steel, concrete, excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete (for 6m to 8m high octagonal /conical GI pole).
165
-
-
ELECTRCAL EXERNAL WORK (INFRA)
-
-
-
FEEDER PANEL- OUTDOOR TYPE
1812.46
-
-
LT PANEL No-1, =1 Nos QTY
-
-
-
(The outer door of the panel is such that user can work/handle it propery, locking arrangement with key should be provided by bidder. The panel is outdoor and should be manufactured as per IP-65 protection)
-
-
-
Supplying and erecting metal work in CRCA sheet including Iron work for supports with fabrication of boxes, panel boards, etc. including cutting, bending, drilling, welding, riveting, treated with anti-rust treatment and duly powder coated or painted with one coat of red lead paint and 2 coats of enamel paint complete.
-
-
-
Supplying and erecting Iron, sheet metal work consisting of CRCA Sheets, Various sections of iron, Plates, Chequered Plates, Rods, Bars, MS pipes, etc. for panel board or any other purposes complete with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority
884.13
-
-
Supplying and erecting extended rotary handle for MCCB with adjustable telescopic rod suitable for up to 400A MCCB.
88
-
-
Providing & erecting 3 Pole MCCB, 415 V, 100A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/ panel as per specification no. SW-SWR/MCCB
26
-
-
Supplying and erecting of any size electrolyte aluminium patti or bar in bus bar chamber / in panel or any other purpose, 500 V with require capacity 99.9% aluminium purity with E91E Grade as per IS 5082 & Current Density 0.8 A per sq. mm. with fixing arrangement (like lug or bottle type lug) to both the end with high grade polyolefin insulation sleeve complete as per specification no. BCPBB (200Amp Bus bar) (with 2x6.0 sqmm Cu wire wiring for meter and switchgear)
52
-
-
Supplying and erecting self-locking arrangement with keys in duplicate, made of brass of grade 1 compliance to IS 729-1979 duly erected, flush with surface of panel / cupboard
223
-
-
Providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm with funnel with a wire mesh for watering and brick masonry block C.l. cover complete with all materials, testing & recording the results as per specification no. EA-EP (1 No for each feeder Panel).
269
-
-
CABLES FOR ALL FEEDER PANEL
-
-
-
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable, 1100 V 4 core 16 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
4752.17
-
-
Supplying, erecting & terminating FR XLPE insulated, galvanised steel wire armoured (round) cable, 1100 V 4 core 6 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided
trench/ pipe as per specification no. CB-LT/AL
3403.88
-
-
Supplying and laying (including excavation of suitable width & depth up to 90 cm) 200 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete.(From Transformer LT Panel to Main MCCB Panel Cable- Panel Room)
22103.14
-
-
Supplying and laying (including excavation of suitable width & depth up to 90 cm) 120 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete.(From Transformer LT Panel to Main MCCB Panel Cable- Panel Room)
17240.45
-
-
EXTERNAL PLUMBING (FOR INDIVIDUAL SITE QUANTITY REFER ANNEXURE - 1)
-
-
-
Providing , laying and fixing ,jointing Eco- drain 160 mm SN 4 Nu- Drain Upvc pipes or of equivalent make, manufacture as per EN 13476 or equivalent as per I.S.15328 with fittings such a bends, tees , coupler, etc, jointing with rubber lubricant including necessary excavation, trench refilling with selective excavated materialetc. complete.
1017.41
-
-
Providing , laying and fixing ,jointing Eco- drain 200 mm SN 4 Nu- Drain Upvc pipes or of equivalent make, manufacture as per EN 13476 or equivalent as per I.S.15328 with fittings such a bends, tees tees, coupler etc, jointing with rubber lubricant including necessary excavation, trench refilling with selective excavated materialetc. complete.
72.67
-
-
Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design:
26
-
-
150x100 mm size P type With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
-
-
-
Constructing brick masonry road gully chamber 50x45x60 cm with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450 mm pre-cast R.C.C. horizontal grating with frame complete as per standard design :
122
-
-
With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
-
-
-
Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design :
26
-
-
Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg( weight of cover 23 kg and weight of frame 15 kg)
-
-
-
With Sewer bricks conforming to IS : 4885
-
-
-
Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design :
13
-
-
Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg( weight of cover 23 kg and weight of frame 15 kg)
-
-
-
With Sewer bricks conforming to IS : 4885
-
-
-
Extra for depth for manholes :
-
-
-
Size 90x80 cm
-
-
-
With Sewer bricks conforming to IS : 4885
-
-
-
Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS:10910 on 12 mm dia steel bar conforming to IS 1786 having minimum cross section as 23 mm x 25 mm and overall minimum length 263 mm and width as 165 mm with space between protruded legs having 2 mm tread on top surface by ribbing on chequering besides necessary and adequate anchoring projections on tall length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacturer’s permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:2:4 (1 cement:2 coarse sand: 4 graded stone aggregate 20 mm nominal size) complete as per design.
52
-
-
Providing and fixing hume pipe septic tank 900mm diameter with vent pipe and cap including necessary (including excavation and laying)
26
-
-
Providing soak pit of size 120cm x 120cm x 120cm including excavating and filling with brick-bats.
26
-
-
EXTERNAL WATER SUPPLY
-
-
-
Providing and laying in trenches 40mm dai. CPVC pipe including necessary excavation, fittings. Refilling trenches etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
436.03
-
-
Providing and laying in trenches 25 mm dai. CPVC pipe including necessary excavation, fittings. Refilling trenches etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
145.34
-
-
Providing & fixing full way lever operated forged brass ball valve of brass body with forged brass hard chrome plated steel ball tested to a pressure not less than 10 Kg / sqcm with threaded / flanged joints complete with nuts, bolts, gaskets, washers etc.
52
-
-
25 mm dia.
-
-
-
Providing & fixing full way lever operated forged brass ball valve of brass body with forged brass hard chrome plated steel ball tested to a pressure not less than 10 Kg / sqcm with threaded / flanged joints complete with nuts, bolts, gaskets, washers etc.
26
-
-
40 mm dia.
-
-
-
Supply, installation, testing and commissioning of vertical multistage centrifugal pumping set with stainless steel SS-304 stage casing and SS-304 impellers with stainless steel SS-316L shaft as per IEC standards and GJL250 cast iron suction & discharge casing, connected to TEFC ventilated induction motor of 2 pole, 2900 RPM, suitable for 400/440 Volts, 3 phase, 50 Hz A.C. supply with SS pressure gauge and with gunmetal isolation cocks, vibration elimination pads, control/starter panel, cable etc. complete with base and frame, nuts and bolts and necessary RCC foundations (by civil vendor) as per requirement as per instructions and pump shall have following duty:
26
-
-
Overhead Tank Filling pumps :
-
-
-
Capacity/Flow Rate - 2.5 M3/Hr
-
-
-
Head - 25 m
-
-
-
1 Set = 2 Nos. Pumps (1 working+1 standby)
-
-
-
RAIN WATER HARVESTING
-
-
-
RWH - Recharge Pit
Providing and constructing recharge pit of 2.0m deep and 1.0m dia of pre-cast RCC rings with 6.5" dia x 25m deep borewell at the floor of recharge pit including installation of combination of solid/perforated PVC casing pipe wrapped around with netlon mesh including 300mm thick sidefilling around outside of RCC rings (annular space) with 40mm size boulders including filling of recharge pit up to 0.5m depth with 25-75mm clean washed gravels from bottom up followed by 0.5m depth of 10-25mm of clean washed stones followed by 0.5m of washed river fine aggregate (natural sand/crushed sand VSI grade finely washed etc.) including netlon mesh between each gravel/fine aggregate (natural sand/crushed sand VSI grade finely washed etc.) media layer including covering with RCC slab, manhole frame & cover, PVC rungs, PVC end-caps, fittings etc. including arrangement for inlet & outlet pipe excavation & backfilling as shown in the drawing.The rate shall be inclusive of all labour, material, wastage, scaffolding, transportation, taxes, including all leads, lifts at all levels. All material should be of approved make. All works complete as per the drawing, technical specification and direction of the Engineer in charge.
26
-
-
Constructing DESILTING CHAMBER of inside size 1200 x 600 x 600 mm in brick work of class 75 with cement mortar 1:4 (1cement:4 coarse sand), inside plastering 12 mm thick with cement mortar 1:4 with floating coat of neat cement including baffle wall as per detail . RCC top slab 150mm thick with 1:2:4 all complete as per standard design and direction of enginner in charge.
26
-
-
External Road Work (Paver Block Works) (FOR INDIVIDUAL SITE QUANTITY REFER ANNEXURE - 1)
-
-
-
Construction of granular sub-base by providing close graded Material, mixing in a mechanical mix plant at OMC, carriage of mixed Material to work site, spreading in uniform layers with motor grader / Paver on prepared surface and compacting with vibratory roller to achieve the desired density, complete as per clause 401 -- Plant Mix Method and Grading - II Material
591
-
-
Providing and fixing factory made Hydraulically pressed Mechanically vibrated and compacted precast inter locking cement concrete paving blocks 80MM thick in M-40 grade of approved size and shape for City streets, small /medium market roads,low volume roads, utility cuts on arterial roads etc. as specified and as per IS 15658:2006 including cost of all materials, manufacturing, curing, transportation of blocks to work site including loading, unloading and stacking as directed, laying paving blocks in position over prepared bed of natural sand / crushed sand of 50 mm thickness including necessary excavation in all stratas, spreading blindge of fine sand over the prepared bed, compacting blocks by plate vibrator etc. complete.
5815.7
-
-
Horticulture Work (FOR INDIVIDUAL SITE QUANTITY REFER ANNEXURE - 1)
-
-
-
Trenching in ordinary soil up to a depth of 60 cm including removal and stacking of serviceable materials and then disposing of surplus soil, by spreading and neatly leveling within a lead of 50 m and making up the trenched area to proper levels by filling with earth or earth mixed with sludge or / and manure before and after flooding trench with water (excluding cost of imported earth, sludge or manure).
741
-
-
Supplying and stacking of good earth at site including royalty and carriage upto 5 km complete (earth measured in stacks will be reduced by 20% for payment).
448
-
-
Supplying and stacking at site dump manure from approved source, including carriage upto 5 km complete (manure measured in stacks will be reduced by 8% for payment) :
741
-
-
Screened through sieve of I.S. designation 4.75 mm
-
-
-
Rough dressing the trenched ground including breaking clods
1474
-
-
Spreading of sludge, dump manure and/or good earth in required thickness as per direction of officer-in-charge (cost of sludge, dump manure and/ or good earth to be paid separately).
741
-
-
Mixing earth and sludge or manure in the required proportion specified or directed by the Officer-in-charge
741
-
-
Flooding the ground with water including making kiaries and dismantling the same.
1474
-
-
Providing & laying Selection no. 1 grass turf with earth 50mm to 60mm thickness on existing ground prepared with proper level and ramming with required tools wooden and than rolling the surface with light roller make the surface smoothen and light watering the same, as per direction of officer in charge
1474
-
-
Providing and displaying of Aglaonema Butterfly having ht.30 cm 10 to 12 fresh, healthy and attractive colorful leaves, well developed in 25 cm size Earthen pot/Plastic pot & as per direction of the officer-in-charge.
240
-
-
Providing and displaying of Aglaonema Snow-White hybrid (three in one), having ht. 30 cm & above with 6 to 8 leaves, bright colour, well developed, fresh and healthy in 25 cm size of Earthen pot/Plastic pot. (Specimen ) & as per direction of the officer-in-charge.
240
-
-
Providing and displaying of Aglaonema ernesto (three in one), having ht. 45 cm & above with 12 to 15 leaves, well developed, fresh and healthy in 25 cm size of Earthen pot/Plastic pot.& as per direction of the officer-in-charge.
240
-
-
Providing and displaying of Aglaonema modestum having ht. 23 cm to 30 cm with 3 to 4 suckers & 15 to 20 leaves, well developed, fresh and healthy in 25 cm size of Earthen pot/Plastic pot. & as per direction of the officer-in-charge.
240
-
-
Providing and displaying of Aglaonema nitida having ht. 30 cm to 45 cm with 8 to 10 leaves, well developed, fresh and healthy with attractive leaves in 25 cm size of Earthen pot/Plastic pot.& as per direction of the officer-in-charge.
240
-
-
Cutting down trees including trunks and branches with girths above 30cm to 60cm and stacking the materials neatly with all lifts and lead of 1000m. as directed and earth filling in the depression/pit if any.
72
-
-
Cutting down trees including trunks and branches with girths above 60cm to 90cm and stacking the materials neatly with all lifts and lead of 1000m. as directed and earth filling in the depression/pit if any.
72
-
-
Cutting down trees including trunks and branches with girths above 90cm to 180cm and stacking the materials neatly with all lifts and lead of 1000m. as directed and earth filling in the depression/pit if any.
72
-
-
Cutting down trees including trunks and branches with girths above 180cm to 270cm and stacking the materials neatly with all lifts and lead of 1000m. as directed and earth filling in the depression/pit if any.
72
-
-
Cutting down trees including trunks and branches with girths above 270cm to 450cm and stacking the materials neatly with all lifts and lead of 1000m. as directed and earth filling in the depression/pit if any.
72
-
-
Cutting down trees including trunks and branches with girths above 450cm and stacking the materials neatly with all lifts and lead of 1000m. as directed and earth filling in the depression/pit if any.
72
-
-
SITE DEVELOPMENT (FOR INDIVIDUAL SITE QUANTITY REFER ANNEXURE - 1)
-
-
-
Providing and fixing kerbstone with led lighting system as per following specifications: dimensions with vertical mounting legs with 10mm horizontal square shape mild steel reinforcements. Illuminated kerb stone having visible dimensions :-500mm x 150mm x 150mm.(as per irc - 86-1983 ) 80mm legs having ms reinforcements shal be embedded in bt/concrete road surface.the kerb stone should have kerb angle of 45 degree, with rubber plugs at both ends of the kerbstones (2 nos)having load carrying capacity - vertical : 1465kg, horizontal : 2349 (certified by govt. Recoganized bodies)having thermal stability -: -40 to +120 degree celcius (certified by govt. Recoganized bodies. Illuminated kerb stones including : ingrace protection and connector rating ip67, electrical wire -(as per is: 694), led strip (as per lm:80) standard. Including for electrical fixing -frp junction box consisting of - 10amp. Switch module power supply(smps)having input voltage - 230v ac, output voltage 36v dc, 2 pole mcb. Illuminated kerb stones having warranty for 3 years. illuminated kerbstone shall be fixed into cast-in-situ cement concrete of m20 grade at base, back filling and grooves, including dismantling, fixing, removal of dismantled material and cleaning etc. Complete. The colour of kerb stone shall be provided as directed by engineer in charge.
1306.8
-
-
Boundary Wall :- Construction of Boundary Wall of 2.7 Metre Height (3.0 x 2.1x 0.115 m Precast Panel + 600 mm Grill including Concertina Wire ) RCC Column & RCC Foundation 3 Metre C/C or as per Structure Desgin, PCC M10 below Foundation & Plinth Beam
Top Beam & Plinth Beam as per Structure Desgin, Precast Panel Size 3.0 x 2.1 x .115 Metre & Above Precast Panel 600 mm Grill Including Concertina Wire, Including necessary earthwork in excavation in all kinds of soil,disposal of surplus excavated earth with all leads and lifts, returning the earth in layers surrounding the Foundation, All RCC including steel reinforcement (Fe500 D) work in cutting ,hoisting and laying in position. etc Complete as per drawings or as directed by Engineer-In-Charge.
422.5
-
-
Provding and fixing Parking Shed including RCC Work up to plinth level or up to pedastal level (Excavation, Back filling, RCC foundation, PCC, Column, Plinth Beam, Pedastal up to 600 mm height or as per structure design) after that MS Steel Structure Column & Purlin etc with Primer and Synthetic enemal paint above MS Steel Structure with Galvalume Roofing Sheet etc Complete as per drawings or as directed by Engineer-In-Charge..
1059
-
-
Providing and fixing mild steel gate with angle iron frame with iron bars and diagonal flats as per the detailed drawing including hinges, pivot block locking arrangement, welding riveting and oil painting of three coats of approved shade
24
-
-
External Signages L.S
24
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements