Maharashtra Natural Gas Limited Tender

Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.

Maharashtra Natural Gas Limited - MNGL Tender

Opening Date14 Sep 2024
Closing Date30 Sep 2024
Tender AmountRefer Documents 
Notes
Download

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply & Installation of TLP (Including Material, Manpower & Transport)

-

-

-

... More
SUPPLY AND INSTALLATION OF MTS/TLP of approved MNGL design. as per existing installation including Terminal plates, diagram Plates foundation bolts, termination with lugs & numbering of TS etc., raising the old foundation further up to 1.5 feet around the 4" dia pipe of TLP with 1:2:4 cement concrete in each foundations complete in all respect as per the drawings, specifications and directions of the Engineer-In-Charge. (Type :Normal) Excluding Supply and Laying of Cable

-

-

-

... More
With lower Bend & Foundation

76

-

-

... More
Without Lower Bend & Foundation - Fixing on the existing foundation.

18

-

-

... More
SUPPLY & INSTALLATION OF MTS/TLP suitable to accommodate the polarization cell along with complete terminal plate for cable connections, door, locking arrangement as per approved design , Synthetic Enamel paint and marking of Chainage Nos & etc. on TLPs, raising the old foundation further up to 1.5 feet around the 4" dia pipe of TLP with 1:2:4 cement concrete in each foundations, as per directions of Engineer in Charge. Excluding Supply and Laying of Cable

-

-

-

... More
With lower Bend & Foundation

16

-

-

... More
Without Lower Bend & Foundation - Fixing on the existing foundation.

8

-

-

... More
Shifting of MTS/TLP along with foundation an up to a maximum distance of 25 Meters as per Scope of Work

30

-

-

... More
Repairing of Existing MTS/TLP foundation with supply and replacement of foundation bolts & nuts

10

-

-

... More
Repairing of MTS/TLP including supply and replacement of damaged door, door locks, terminal plate ,diagram plate

30

-

-

... More
Repairing of AJB/ CJB including supply of new locks & latch for the outer enclosure

6

-

-

... More
Pipe To cable connection-(Supply, Installation, Including Material, Manpower & Transport)

-

-

-

... More
Pin Brazing on Charged Pipeline

160

-

-

... More
Thermit Weld on Uncharged Pipeline

40

-

-

... More
Supply and fixing of Neo-preen gasket

40

-

-

... More
Supply of corrosion coupons with mangnetic read switch and reference cell including 1c x 6 sq mm cable for reference cell and 1c x 10 sq mm cable for corrosion coupon,pinbrazing connection encapsulation kit etc. (Supply & installation of AC corrosion coupons with cables. The coupon should have exposed surface area of 1 cm². Of make Mc miller USA .)

36

-

-

... More
Transformer Rectifier Unit (Including Material, Manpower & Transport)

-

-

-

... More
Supply & Replacement of Faulty control cards in TR unit (( Card No. CECO- 103A, CECO- 104C1, CECO- 105D1, CECO-106, CECO- 118B,CECO 107,CECO 118B & CECO118C) etc.)

20

-

-

... More
Supply ,installation, testing and commissioning OF Digital Meters

26

-

-

... More
Supply & replacement of new / Repairing of faulty GPS interrupter with antenna

6

-

-

... More
Supply and installation new contactors/MCBs in CP panel

10

-

-

... More
Supply & Installation of fuses of different ratings in TRU.

40

-

-

... More
Calibration of all meters of TRU (yearly)

20

-

-

... More
Supply and installation of Display Board & Mother Board Type DB1

10

-

-

... More
Supply and installation of Silicon Controlled Rectifier SCR1

4

-

-

... More
Supply and installation of SCR and Diode Module

4

-

-

... More
Supply and Installation of RC Surge Diverter

4

-

-

... More
Supply and Installation of Auxiliary Transformer-TR2(5 Winding)

4

-

-

... More
Supply and installation of Reference Selector, Auto/Manual Mode, Coarse Selector, Fine Selector & Toggle switch

10

-

-

... More
Supply and Installation of Filter circuit and lightening capacitor

8

-

-

... More
Supply and Installation of Transformer Rectifier Unit contactor

10

-

-

... More
Supply and Installation of Anode Ground Bed (Including Material, Manpower & Transport)

-

-

-

... More
Supply of water and coke breeze to anode bed to maintain its resistance minimum Ohm.(Yearly)

20

-

-

... More
Supply & Installation of set of resistors and shunts for AJB of various ratings as per instruction of EIC.

10

-

-

... More
General Maintenance (Including Material, Manpower & Transport)

-

-

-

... More
Supply and installation of pre-packed Magnesium anodes (7.7 Kg)

10

-

-

... More
Supply and installation of pre-packed Zinc Grounding Cell (pack of 11 Kg + 11 Kg)

20

-

-

... More
Supply & laying of AC mitigator for mitigation of ac interference at HT line.

500

-

-

... More
Supply and installation of Zn ribbon anodes

30

-

-

... More
Cable jointing / Repairing of underground Cable of size 4-10 Sq MM

30

-

-

... More
Cable jointing / Repairing of underground Cable of size 25-35 Sq mm

20

-

-

... More
Supply, installation, laying, ferruling/tagging and termination of cables of different sizes as per the attached drawing & requirement

-

-

-

... More
6 Sq.mm(PE/PVC,XLPE)

1000

-

-

... More
10 Sq.mm(PE/PVC,XLPE)

1000

-

-

... More
25 Sq.mm(PE/PVC,XLPE)

500

-

-

... More
35 Sq.mm(PE/PVC,XLPE)

500

-

-

... More
Supply & Installation of CP Accessories (Including Material, Manpower & Transport)

-

-

-

... More
Maintenance of Polarization Cells(Kirk cell 5kA)

20

-

-

... More
Supply and Installation of Polarization, polarization cells (Solid State -Static type), at HT Line Crossings including Supply and installation of Type H Test stations of suitable size to accommodate the Static Type Polarsation Cells / replacement of smaller existing Test station with H Type wherever required for installation of the polarization cell [As per Scope of Work] (Supply and installation of solid state polarization cell at HT line location or as per new ac / dc interference report.)

30

-

-

... More
Supply, Installation, Testing and commissioning of Static type Spark gap arrestors across IJ's

40

-

-

... More
Supply, installation, testing & commissioning of permanent reference cell as per the requirement (Make from approved vendor)

30

-

-

... More
Supply, installation, testing & commissioning of computerized test stations(CTSU)

4

-

-

... More
Repair pipe coating by cold applied tape including material and manpower required

400

-

-

... More
Checking effectiveness of IJ (once in two year)

160

-

-

... More
Inspection of cased crossing (once in two year)

50

-

-

... More
Painting of TLP support structure and Foundation along with naming TLP and chainage No (as per MNGL requirement)

1008

-

-

... More
CIPL Survey along UG Pipeline network

150

-

-

... More
DCVG Survey along UG Pipeline network

75

-

-

... More
AC interference Survey

90

-

-

... More
DC interference Survey

40

-

-

... More
ECDA Survey along UG Pipeline network [As per Scope of Work]

70

-

-

... More
New CP System Supply and Installation, Testing & commissioning. Along with TR unit of rating 25V/25A, Outdoor Type with RMU data logger, Deep well anodbed max 70m Depth, AJB,CJB,reference cell, all CP Cables , Pin Brazing (all items required for CP shall be accommodated in same SOR)

2

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.