Maharashtra Maritime Board Tender
Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.
Maharashtra Maritime Board - MMB Tender
Aerospace and Defence
Eprocure
Opening Date30 Jul 2024
Closing Date13 Aug 2024
Tender Amount₹ 41,81,64,714
Costs
EMD
₹ 20,91,000Document Cost
₹ 3,540Tender Fee
Refer Documents
Summary
Providing Pontoon For Ro-ro Jetty And Allied Facility At Kashid Tal. Murud Dist. Raigad.3rdcall
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MMB_1060845_1Bid Award Id
ViewTender No
MMB/2024-25/Reg.1/B2/17Tender Authority
Maharashtra Maritime Board ViewPurchaser Address
-Website
http://https://mahammb.maharashtra.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Providing and maintaining temparory platform for erecting boring machined in river bed to the depth of standing water 2 m and above and of size 3.50 x 4.00 M by using 20 Nos. of M.S. empty barrels in M.S. frame made of M.S. angle size 50 x 50 x 5 mm with fabrication and over it a jungle wood planks platform of size 3.50 x 4.00 x 0.03 M size including supplying of nylon rope 24 mm dia. for anchoring platform include passage platform and enganging a labour etc. complete. 2 m and Above.
2
-
-
Shifting boring plant with all its components and reinstalling the same at the directed place including all its charges etc. complete.
10
-
-
Providing tun tappa core boxes of jungle wood of size1.25mx 0.35x 0.15m for preserving core sample with all fixtures and fastening handles including locking arrangment etc . complete.
30
-
-
Carrying of detailed topographic survey by using total station along the existing or new road including taking L-section and cross section at every 30 meter ROW ,taking at least 10 spot levels per cross section, picking up all existing details inside the Row like electric telephone line, encroachments, structures etc. connecting all the primary total station control points by G.I.S.Bench marks level or whichever available with department using auto level and preparing Auto CAD plan by using above data taking out 1 set of black and white printout on 50 micron polyster film sheet A2 size and 2 sets of coloured printout on A2 size submitting soft copy all data on CD. Plain Terrain New Alignment
2.5
-
-
Excavation for foundation in earth, soils of all types, sand, gravel, soft murum including shoring and strutting, dewatering as necessary and disposing off excavated stuff as directed etc. complete. ( By /manaual Means )
182.25
-
-
Providing rubble filling of trap stones for foundations including filling voids with sand/grit and compaction etc complete.
151.88
-
-
Providing and laying Cast in situ/Ready Mix cement concrete in M20 of trap metal for bed blocks, foundation blocks and such other items including bailing out water, Steel centering, formwork, laying/ pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.), with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
18.23
-
-
Providing and laying cast in situ / ready mix M40 RCC for 800 mm diameter bored piles each of load capacity as per design and of specified diameter of as directed, placed through steel shell sunk to the required depth through all strata except rock, excluding provision of reinforcement including placing concrete by tremie arrangement, compaction of concrete and withdrawal of steel shell with fully automatic micro processor based PLC with SCADA enabled with reversible drum type mixer/ concrete batch mix plant (pan mixer) etc. complete.with VSI quality artifical sand (depth 0 to 5 metre)
350
-
-
Providing and laying cast in situ / ready mix M40 RCC for 800 mm diameter bored piles each of load capacity as per design and of specified diameter of as directed, placed through steel shell sunk to the required depth through all strata except rock, excluding provision of reinforcement including placing concrete by tremie arrangement, compaction of concrete and withdrawal of steel shell with fully automatic micro processor based PLC with SCADA enabled with reversible drum type mixer/ concrete batch mix plant (pan mixer) etc. complete.with VSI quality artifical sand for depth 5 to 10 m
350
-
-
Providing and laying cast in situ / ready mix M40 RCC for 800 mm diameter bored piles each of load capacity as per design and of specified diameter of as directed, placed through steel shell sunk to the required depth through all strata except rock, excluding provision of reinforcement including placing concrete by tremie arrangement, compaction of concrete and withdrawal of steel shell with fully automatic micro processor based PLC with SCADA enabled with reversible drum type mixer/ concrete batch mix plant (pan mixer) etc. complete.with VSI quality artifical sand for depth 10 to 15 m
350
-
-
Providing and laying cast in situ / ready mix M40 RCC for 800 mm diameter bored piles each of load capacity as per design and of specified diameter of as directed, placed through steel shell sunk to the required depth through all strata except rock, excluding provision of reinforcement including placing concrete by tremie arrangement, compaction of concrete and withdrawal of steel shell with fully automatic micro processor based PLC with SCADA enabled with reversible drum type mixer/ concrete batch mix plant (pan mixer) etc. complete.with VSI quality artifical sand for depth 15 to 20 m
350
-
-
Providing, placing and driving in position 6mm thick permanent MS liner up to required depth with 12 mm thick MS cutting edge of 0.50 meter length of bottom including fabricating, cutting the MS sheet to required diameter and shape, welding the joints and driving with the help of required machineries, all materials, labour and lift etc. complete.
380.17
-
-
Extra for Chiselling in hard rocks including removing and stacking the loose material and disposing the unserviceable materials as directed etc. complete.
1000 mm dia
520
-
-
Providing and laying in situ / ready mix controlled M-40 cement concrete of of trap metal for reinforced cement concrete caps over piers and abutments including necessary sacffolding plywood/steel formwork, compacting by vibrating, finishing in CM 1:3 and curing etc complete ( Excluding reinforcement) With reversible drum type mixer/ concrete batch mix plant (pan mixer) . with fine agreegates of required specifications ( VSI sand finely washed etc )
123.75
-
-
Providing and laying in situ / ready mix M-40 controlled cement concrete of trap metal for RCC work in main/ cross girders, diaphrams etc. including ramming, vibrating, curing, formwork, centering and finishing in cement plaster excluding reinforcement etc. complete. (with fully automatic micro processor based PLC with SCADA enabled concrete batch mix plant / pan mixer and fine agreegates of required specifications ( VSI sand finely washed etc )
176.11
-
-
Providing, transporting and placing in position M-40 precast pretensioned concrete girders as per drawings and technical specifications etc. complete.
220.79
-
-
Providing and laying in situ / ready mix M-40 controlled cement concrete of trap metal for RCC work in solid/ deck slab etc. including ramming, vibrating, curing, formwork, centering and finishing in cement plaster excluding reinforcement etc. complete. (with fully automatic micro processor based PLC with SCADA enabled concrete batch mix plant / pan mixer and fine agreegates of required specifications ( VSI sand finely washed etc )
805.44
-
-
Providing and fixing in position HCRM / CRS (Corrosion Resistant Steel) bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete. of approved brands (TATA TISCON/SAIL/RINL/ARCELLOR MITTAL/JSW)
789.07
-
-
Providing Reinforced cement concrete crash barrier at the edges of the road, approaches to bridge structures and medians, constructed with R.C.C. M 30 Grade concrete with HYSD reinforcement conforming to IRC:21 and dowel bars 25 mm dia, 450 mm long at expansion joints filled with pre-moulded asphalt filler board, keyed to the structure on which it is built and installed as per design given in the enclosure to MOST circular No. RW/NH - 33022/1/94-DO III dated 24 June 1994 as per dimensions in the approved drawing and at locations directed by the Engineer, all as specified etc. complete. Spec: MORT and H 2013 Cl 811 Page No 360
124
-
-
Providing and casting in situ or precast tapering R.C.C. M-20 Barrier type Kerb without gutter ( as per IRC 86 1983) embedded 125mm below ground level over M-10 PCC finished neatly with C.M. 1:2, setting the same in C.M. 1:2, including the required excavation in any strata and removing the excavated stuff any where in city and redoing the surface as specified and directed by Engineering In-charge. Using Concrete Batching and Mixing Plant
62
-
-
Stamp Concrete of 100mm Thickness - Providing and Laying in-situ M30 Grade unreinforced plain cement stamp concrete of 100mm thickness pavement over a prepared sub base with 43 grade cement, coarse and fine aggregate (natural sand / VSI grade finely washed crushed sand) Confirming to IS 383, as per mixed in a batching and mixing plant / non tilting mixer and weigh batcher as per approved mix design, admixtures, transporting to site in nagpur city with lead upto 20KM (on Inner Ring Road from Avasti nagar to wadi), spreading, laying with approved make pover, compacted and finished in a continous operation, finishing to lines and grades Also Providing, Placing and applying stamp powder which is light fast UV resistant pigment with appropriate chemical compounds of desired colour on base concrete after excess bleed water has evaporated using dry shake method @5kg per sqm. Including texturing, and covering with plastic sheet (min 200 micron thickness) and also applying two coats of UV-stable,30 % solids clear sealer @ 150 to 250 gms per sqm using surface roller and protecting from falling dust,dirt and curring by curring compound / by providing cement vata in cement Mortor 1:8 @ 0.6m x 0.6m center to center, admeasuring 80mm at bottom and 40mm at top with
depth of 75mm and maintaining the same throughout curing period by any other method approved by Engineer-incharge or Landscape architect etc. complete.
93
-
-
Providing and applying tack coat on the prepared surface heating by fames in Boiler and spraying bitumen with sprayer on Dry / Hungry B.T. surface 3 kg/10 sqm. (VG-30 bulk bitumen rates are considered to arrive at rates)
992
-
-
BITUMINOUS CONCRETE:--Providing and laying bituminous concrete using crushed aggregate of grading 1, premixed with bituminous binder @5.40% by weight of total mix and filler, transported at site with VTS, laid over a previously prepared surface, finished to the required grade ,level, alignment, and rolling to achieve the desired density for 50mm compacted thickness with drum mix plant with SCADA, Sensor paver and Vibratory roller excluding prime/Tack coat etc. complete --Bitumen of specified grade with stone dust filler. (VG-30 bulk bitumen rates are considered to arrive at rates)
39.68
-
-
Providing and laying 12 mm thick mastic asphalt wearing course on top of deck slab excluding prime coat with paving grade bitumen meeting the requirements given in table 500-29, prepared by using mastic cooker and laid to required level and slope after cleaning the surface including providing antiskid surface with bitumen precoated fine grained hard stone chipping of 4.75 mm nominal size at the rate of 0.005 cum per 10 One Square Metre and at an approximate spacing of 10 cm center to center in both directions, pressed into surface when the temperature of surfaces not less than 100 deg C, protruding 1 mm to 4mm over mastic surface as per clause 515 etc. complete.
1984
-
-
Providing and Laying hot applied thermoplastic road marking strip on Bituminous Surface of specified shade/ colour of 2.5 mm thick including 1.5 Refractive index reflectorizing glass beads @ 250gm/sqm .Thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC 35:2015. Initial Dry reflectivity RL shall be 250 mcd/sqm/lux measured in the initial 7 days and sustained reflectivity RL of 100 mcd/sqm/ lux and Qd of 100 mcd/sqm/ lux measured at the end of 2 years by means of a Standard Reflectometer of Zehntner, Easylux, Delta make capable of measuring RL & QD both according to IRC 35:2015 clause 15.5. The finished surface to be level, uniform, and free from streaks and holes complete as per direction of Engineer-in-charge and in accordance with applicable specifications.(Refer MORTH Clause 803 for technical Specification and Performance for IRC 35:2015).
288
-
-
Prividing and fixing pressure relief pipes of 100 mm diametre of AC / PVC as per drawing for R.C.C Raft, galaries returns, abutments, wing wall etc complete..
595.2
-
-
Providing and fixing informatory sign boards of size 0.90 x 0.60 m made out of 14 guage Aluminum sheet bonded with IRC Specified colour of retro reflective sheeting of Type IV High Intensity Micro-Prismatic Grade Sheeting (HIP) having pressure sensitive / heat activated adhesive, IRC Specified colour retro reflective cutout border & messages having pressure sensitive adhesive having border & messages in IRC Specified colour background including on frame of with angle iron frame of size 35 x 35 x 5 mm and two M.S. angle iron post of size 65 mm X 65 mm X 6 mm, 3.65 m long, duly painted with flat oil paint having alternate black and white bands of 25 cm width including G.I. fixtures etc; fixing the boards in 1:4:8 concrete block of size 60cm X 60cm X 75cm including transportation etc; complete. Alluminium sheet Type IV High Intensity Micro-Prismatic Grade Sheeting
10
-
-
Providing and fixing 90 cm x 60 cm Marble plate engraving 10 cm. height letter, figures including painting the lefters/figures with approved colour and shade complete
1
-
-
Providing and applying epoxy paint primer with middle coat and top coat to superstructure including scaffolding etc complete.
10853.3
-
-
Providing Temporary Gantry platform using structural steel work in rolled sections like joists, channels, angles, tees etc. as per detailed design and drawings or as directed including cutting, fabricating, hoisting, erecting, fixing in position making riveted / bolted /welded connections with connecting plates, braces etc. and including one coat of anticorrosive paint and over it two coats of oil painting of approved quality and shade etc. complete. The item includes all trasnporation, fabricting all materials, labour,required number of dummy piles for erection of gantry over shore and equipment required for driving and casting of reinforced cement concrete piles including dismanatling platform and dummy piles etc. after completion of work and demobilization from site with all materials and proper cleaning etc complete.
Payment Terms
1. 20% on erection of grantry
2. 40% on completion on 50% of scope (Pile)
3. 30% on another 50% completion of complete scope of piling
4. 10% demolition & demobilization of grantry. Note:- The Contractor Should design the gantry as per site condition & get it proof checked from expert agencies like IIT/VJTI etc. before actual execution. Approval to the design shall be obtained from Maharashtra Maritime Board
1
-
-
Providing and fixing of BITUFLEX CLOSE CELL FOAM of size30mmx30mmin doublelayer in the expansion joints inR.C.C framed structure (at floor level / at terrace level / interior columns) for overlappingof closed cell foamjoints, applying TP-40 PRIMER on both the sides of concrete surface, fillingthe25mmx25mm gap with the POLYDEE-41 highly flexible sealant and covering the joint with Polydee-LM,150 mm width in 2 coats etc. complete.
48
-
-
Providing and laying cast in situ / ready mix M40 RCC for 1000 mm diameter bored piles each of load capacity as per design and of specified diameter of as directed, placed through steel shell sunk to the required depth through all strata except rock, excluding provision of reinforcement including placing concrete by tremie arrangement, compaction of concrete and withdrawal of steel shell with fully automatic micro processor based PLC with SCADA enabled with reversible drum type mixer/ concrete batch mix plant (pan mixer) etc. complete.with VSI quality artifical sand (depth 0 to 5 metre)
200
-
-
Providing and laying cast in situ / ready mix M40 RCC for 1000 mm diameter bored piles each of load capacity as per design and of specified diameter of as directed, placed through steel shell sunk to the required depth through all strata except rock, excluding provision of reinforcement including placing concrete by tremie arrangement, compaction of concrete and withdrawal of steel shell with fully automatic micro processor based PLC with SCADA enabled with reversible drum type mixer/ concrete batch mix plant (pan mixer) etc. complete.with VSI quality artifical sand for depth 5 to 10 m
200
-
-
Providing and laying cast in situ / ready mix M40 RCC for 1000 mm diameter bored piles each of load capacity as per design and of specified diameter of as directed, placed through steel shell sunk to the required depth through all strata except rock, excluding provision of reinforcement including placing concrete by tremie arrangement, compaction of concrete and withdrawal of steel shell with fully automatic micro processor based PLC with SCADA enabled with reversible drum type mixer/ concrete batch mix plant (pan mixer) etc. complete.with VSI quality artifical sand for depth 10 to 15 m
200
-
-
Providing and laying cast in situ / ready mix M40 RCC for 1000 mm diameter bored piles each of load capacity as per design and of specified diameter of as directed, placed through steel shell sunk to the required depth through all strata except rock, excluding provision of reinforcement including placing concrete by tremie arrangement, compaction of concrete and withdrawal of steel shell with fully automatic micro processor based PLC with SCADA enabled with reversible drum type mixer/ concrete batch mix plant (pan mixer) etc. complete.with VSI quality artifical sand for depth 15 to 20 m
200
-
-
Providing and laying cast in situ / ready mix M40 RCC for 1000 mm diameter bored piles each of load capacity as per design and of specified diameter of as directed, placed through steel shell sunk to the required depth through all strata except rock, excluding provision of reinforcement including placing concrete by tremie arrangement, compaction of concrete and withdrawal of steel shell with fully automatic micro processor based PLC with SCADA enabled with reversible drum type mixer/ concrete batch mix plant (pan mixer) etc. complete.with VSI quality artifical sand for depth above 20 m
80
-
-
Providing and fabricating structural steel work in rolled sections like joists, channels, angles, tees etc. as per detailed design and drawings or as directed including cutting, fabricating, hoisting, erecting, fixing in position making riveted / bolted/welded connections without connecting plates, braces etc. and including one coat of anticorrosive paint and over it two coats of oil painting of approved quality and shade etc. complete.
100
-
-
Supply, fabricate, transport, handle and erect in position of structural steel shapes, plates, special plates with through thickness quality and built-up sections in pontoon and linkspan confirming to steel grades (ASTM-A131-DH36) as specified in construction drawings and specifications including profile cutting, assembling, hoisting, fixing in position, welding, inspection as per drawings including cost of all materials, fitting charges, all labour charges, transportation charges and minor tools etc. complete. The cost shall include all fabrication, transportation of the pontoon assembly, minor equipment, installation of pontoon and all labour charges etc. complete. Following clauses apply to the floating pontoon fabrication and installation. i. Structural steel shall comply with Project Specifications Vol-III – Clause 1.5 and the coating system shall comply with the Project Specifications Vol-III Clause 1.9. ii. Plan approval from classification society has been obtained by Employer including payment to Classification society for plan approval. iii. Contractor shall obtain classification society approval for its material, fabrication and installation including payment to certification agency for inspection and survey, surveyors to visit, inspect and approve the materials, fabrication and installation. iv. Contractor shall arrange for the transportation of surveyors and pay for the day charges as per the number of visits required during fabrication and installation. v. All fabrication, welding, cutting, bending of plates on site to be as per BS 5400 Part 6 / AWS D1.1 and relevant classification society (IRS/ABS/BV etc.) rules etc. including surveying/ supervision of fabrication and obtaining certification approval from classification society (IRS/ABS/BV etc.). vi. All tests on materials + Welds (Ultrasonic, dye penetration for welds + Water tightness test).
Note : Contractor shall contact IIT Chennai for detail design, drawing, cross section, etc., for the linkspan, pontoon, mooring, dolphins, guide piles and other accessories. Payment forwords this activities of IIT Chennai shall be paid by contractor. No separate payment shall be paid in this regards.
All the drawings shall be got approved from MMB before actual execution at site.
769
-
-
Supply, fabricate and install Aluminum anodes of 95 kg net weight (GALVALUM III) as per specifications and drawings to the pontoon bottom surface and inside the compartments as per the locations indicated in the drawings using welded connections to protect the surface against corrosion. The anode aracteristics, design and material composition shall be all as per specifications
52
-
-
Supply and provide manpower for surface preparation to SA 2.5 and Painting internal and external surfaces of pontoon & Link span with 4 coats of anti-corrosive epoxy painting system with minimum 750 DFT including tools, equipment, manpower, material etc. all inclusive as per specifications.
10545
-
-
Supply, and provide manpower for Non-skid Painting on the deck surfaces of pontoon & Link span of suitable specification including tools, equipment, manpower, material etc. complete. Antiskid finish shall be inimum 5.5mm Nominal Thickness using Cicol NT Slurry by ROCOL UK (or equivalent approved make) + 5.0mm compatible aggregate on top surface of the pontoon.
914
-
-
Supplying, testing and fixing and installation of cast iron bollards of capacity 20 MT Safe Working Load as per drawings and pecifications including the cost of bollard with all its accessories, all labour charges, transportation charges up to site and minor tools etc., omplete.
4
-
-
Supplying, transporting, fixing and installation of watertight steel manhole covers provided on the deck surfaces of pontoon as shown in drawings including the cost of manhole cover with all its accessories,cover lates,handles,bolts, all labour charges, transportation charges up to site and minor tools etc., complete
20
-
-
Supplying, transporting, fixing and installation of UHMW - PE Rubber Pad as shown in drawings including the cost of Rubber Pad and all other fittings,labour charges, transportation charges up to site and minor tools etc., complete.
6
-
-
Supplying, transporting, storing, fabricating & erecting in position and testing/examining welded and hot dipped galvanised (120 microns) steel works made of pipes, plates, shapes, bars, strips, and rods for base plates, crash barrier, edge protection and miscellaneous works including labour charges, tools, tackle etc. complete.
12
-
-
Supplying, transporting, fixing and installation of Trelleborg RCP1000 Ramp Protector as shown in drawings including the cost of Ramp Protector and all other fittings,labour charges, transportation charges up to site and minor tools etc., complete.
7
-
-
Supplying, Testing, fixing and installation of cast iron bollards of capacity 60 MT safe working load as per drawing and specification including the cost of bollard with its designing and taking approval, also its accessories, all labour charges, transportation charges up to the site and minor tools etc. complete or as direrected bu engineer incharge.
10
-
-
Providing and fixing fenders made from used tyres including fixing by stainless steel chain links of 8mm dia. and anchor bolts of 16 mm diameter etc. complete as per drawing and as directed under tidal range.
38
-
-
D shape Rubber fenders (300x300x200 hollow)
38
-
-
Supplying, Testing, fixing and installation of dual super cone fenders system using SCN 1050 F3.1 fender or its equivalent including cost of fender with all its accessories, steel fender frame, PTFE facia pads (low friction), chains, anchors including all labour charges, transportation charges up to site, installation and fixing of fenders on to the concrete dilphins and minor tools etc. complete. For 5 Nos.
1
-
-
Supplying, erecting & terminating FR XLPE insulated, galvanised steel wire armoured (round) cable 1100 V, 4 core 6 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU (CSR 2023-24, 7-2-32/115)
250
-
-
Providing & erecting 8 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 135 mm A/F, top 70 mm A/F on provided foundation as per specification no. OH-PL/OPL (CSR 2023-24, 8-2-14/130)
8
-
-
Making M-20 grade reinforced cement concrete foundation by considering the safe soil bearing capacity at site as 10 T/sq.m at 1.5m depth including supply of steel, concrete, excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete (for 9m & 10m high octagonal/conical GI pole). (CSR 2023-24, 16-3-10/217)
8
-
-
Supplying, installing and testing earthing with galvanised iron earth plate size 60 x 60 x 0.6 cm complete with all accessories of GI materials & recording the results as per specification No. EA-EP (CSR 2023-24, 9-1-1/140)
3
-
-
Supplying and erecting GI strip of required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint in an approved manner with joints required as per specification no EA-EP. (CSR 2023-24, 9-2-3/140)
3
-
-
Supplying & erecting Carbon Dioxide (CO2) fire extinguisher of 4.5 kg. capacity cartridge type conform to IS 2878 /15683 complete erected with necessary clamp made from 50 x 6 mm. M. S. flat with nut & bolts routed in wall complete. (CSR 2023-24, 13-14-1/203)
3
-
-
Supplying and erecting integrated LED street light fitting 85-90W IP65 & IK08 class having single piece pressure die-cast aluminium housing, having system lumens output of Min. 9300 Lumens, min. efficacy of 110 lumen/W, CRI70, CCT upto 6500K, THD0.95, operating range of 140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs at L70B50 including driver complete with minimum 2 Years warranty as per specification No. FG-ODF/SL. (CSR 2023-24, 2-3-7/20)
16
-
-
Supplying and erecting integrated LED street light fitting 60W IP65 & IK08 class having single piece pressure die-cast aluminium housing, having system lumens output of Min. 6600 Lumens, min. efficacy of 110 lumen/W, CRI70, CCT upto 6500K, THD0.95, operating range of 140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs at L70B50 including driver complete with minimum 2 Years warranty as per specification No. FG-ODF/SL. (CSR 2023-24, 2-3-5/19)
6
-
-
Supplying and erecting integrated LED flood light fitting Max. 195W IP65 & IK07 class having pressure die-cast aluminium housing, having system lumens output of Min. 23400 Lumens, min. efficacy of 120 lumen/W, CRI70, CCT upto 6500K, THD10%, p.f. 0.90, operating range of 140-270V, inbuilt surge protection of 4 kV, Life class of 50,000 Hrs at L70B50 including driver with U shaped bracket with minimum 2 Years warranty as per specification No. FGODF/FL. (CSR 2023-24, 2-3-18/21)
6
-
-
Supplying and erecting 16 m (clear height) motorized high-mast (Top-150mm, Bottom- 360mm) hot dipped galvanized material with average minimum thickness 65 micron, made from high tensile structure grade steel as per BSEN -10025 S355/E350 & 3 mm thickness, with base plate 25 mm thick x OD 520 mm grade as per IS-2062, pole made in single section & submerge arc welded, with lowering & raising motorized unit, wire rope stainless steel 316 grade 2 nos., 7x19 construction 5mm, SG-DG U clamps, double drum winch assembly 350 kg, 5x2.5 sq.mm flexible copper cable with lantern carriage assembly suitable for max. 12 nos luminaries and its control gear box, lightning arrestor, arrangement for fixing aviation light, night glow reflector on pole at suitable height, high-mast with serial number, factory inspection report/test report of high-mast should be provided as per specifications on provided foundation J type stud/bolts with double check nuts & necessary accessories complete. specification no. OHPL/HM (CSR 2023-24, 8-2-2/129)
1
-
-
Providing and erecting galvanised 1000mm single arm sword type bracket with FRP dome and ball as per specification no. OH-PL/BKT (CSR 2023-24, 8-2-19/131)
6
-
-
Supplying & erecting three phase, 415V, street light control panel upto the max load of 12kW, TPN MCB 63A, powder coated CRCA 14 SWG sheet, outdoor type, having IP54, IK10 protection suitable rating contactor, 24 hrs. astronomical time switch with minimum 5 years battery back up, auto/manual selector switch, ON/OFF push buttons, indicator lamps, control wiring, metering device, etc. for automatic operation with overcurrent, short circuit, earth fault protection on provided iron frame / CC foundation as per specification SW-STCP. (CSR 2023-24, 5-2-6/75)
1
-
-
Supplying, erecting, testing and commissioning of diesel generating set with alternator of 62.5 kVA output continuous rating, 3 phase, 415 V, 50 Hz, 0.8 p.f., A.C. supply, a totally enclosed air cooled / liquid cooled multi-cylinder diesel engine developing suitable BHP at 1500 rpm with 10% overload for 1 hour in 12 hours, along with standard accessories, self-excited, self-regulated, screen protected alternator with static excitation system running at 1500 RPM as per IS 4722-2001 with voltage regulation +/- 5 %, with performance class G2/G3 and maximum fuel consumption 11.3 ltr/hr @75% loading. Both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on anti-vibrating pads, with standard control panel comprising meters, switchgears, indicators connected with suitable wires/cables, the complete set enclosed in composite acoustic enclosure as fully assembled integral unit made of 16 SWG CRCA sheet, sound absorbing material to restrict sound level up to 75 dB at 1.0 m, provided with first filling of oil, diesel not less than 150 ltr etc., on provided M20 grade CC foundation as per specification no. GEN-DG (CSR 2023-24, 11-1-10/159)
1
-
-
Item No. 01: Panel Fabrication Supplying, erecting, testing & commisioning GI sheet 1.6 mm (16 SWG) having zinc coating of 350 microns with galvanization process compliance to IS 2629:1985 to be used for fabrication of boxes panel boards etc. including cutting, bending, drilling, welding, riveting etc. and painting with one coat of red lead paint and 2 coats of enamel paint as per specification no. CP/SH/CR (CSR 2023-24, 6-1-6/89)
80
-
-
Item No. 2: 'Iron Work Supplying and erecting iron, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates,rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the site engineer. (CSR 2023-24, 6-1-19/90)
Note:-
1. Quantity of iron/sheet metal work shall be considered and worked out as per steel data table. (New)
2. For manufacturing of panel, CRCA sheet of min 1.6 mm to 1.8 mm thickness shall be used for external enclosure and min 1.2 to 1.4 mm thickness for internal separation and min 2 mm to 2.4 mm thickness shall be used for cable entry / gland plate .(New) 3. For fire retardant plywood increase overall rate by 25% in item no 6-1-14
150
-
-
Providing and erecting galvanised 1000mm single arm sword type bracket with FRP dome and ball as per specification no. OH-PL/BKT (CSR 2023-24, 8-2-20/131)
16
-
-
Item No.9: Supplying, erecting & marking FP MCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-MCB (CSR 2023-24, 5-3-13/76)
1
-
-
Supplying, erecting & marking SP MCB 6A to 32A, B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-MCB (CSR 2023-24, 5-3-3/76)
5
-
-
Supplying, erecting, testing & commisioning 25 kVAr, 3 phase, 50 Hz., APFC Panel with derated power contactor of suitable rating for capacitor switching Application for each step controlled by microprocessor based APFC relay consisting of 1,2,2,5,5,5,5 or suitable steps of MPP /APP type capacitor with 525 V and having minimum overcurrent capacity of 1.8 In, peak inrush current capacity 300 In and minimum life 150000 hours with detuned aluminium wound reactor of 7/ 14% for each step, APFC Panel shall suitable rating MCCB as incomer and each branch/step shall have separate isolation with MCCB/MCB of Suitable rating for protection, compliance to IEC 61439 and power quality IEC 61921 standard as per specification no. CP-ED/APFC.. (CSR 2023-24, 6-9-16/106)
1
-
-
8 MP IR BULLET CAMERA
Image Sensor Type : CMOS
Resolution: 4K HD (3840 X 2160Pixel)
IR illumination Range(mtr): 50
Day/Night Capable : YES
Product id: 5116877-7281564903
5
-
-
IP DOME CAMERA 2 MP
Image Sensor Type :CMOS
Image Sensor Size : 0.357 inch
Resolution : Full HD (1920 x 1080Pixel)
Day/Night Capable : Yes
IR illumination Range(mtr) : 120
Type of Camera Housing : DOME CAMERA
IP Camera :Yes
Product id: 5116877-33299375236
3
-
-
NVR 32 CHANNEL
Type of Recorder: NVR
Total Number of Input Channels : 32
Maximum Recording Resolution supported :12 MP (4000 X 3000)
Recording Speed for all channels(fps) : upto 30
Product id: 5116877-66699160158
15
-
-
SURVEILLANCE TYPE SATA HDD 4TB
Capacity of Drive (GB) : 4000
Type of Drive : SATA HD
Warranty (Years): 1
Product ID : 5116877-88316962586
9
-
-
Supply, Installation, Testing, Intgeration & Commissioning of 49" LCD monitor at Conf. Room for display of total water system (Online)
1
-
-
Supplying, erecting, testing and commissioning of microprocessor based AMF panel suitable for diesel generating set of above 62.5 kVA upto 82.5 kVA capacity 3 phase, 415 V, 50 Hz, A.C. supply with all standard features, safeties etc as per specification no. GEN-AMF. (CSR 2023-24, 11-2-9/164)
1
-
-
Supplying, erecting & terminating 5 m HDMI cord low voltage grade minimum 4k compliant to be laid in provided conduits with male/female 19pin HDMI connectors complete. (CSR 2023-24, 19-1-22/274)
30
-
-
Supplying and installing FR PVC sheathed HDPE insulated copper cat-6 cable with rodent proof and anti termite jacket suitable for networking compliant with ANSI/TIA-568.2-D standards in provided conduit/casing-ncapping as per specification no. WG-ELVC/NC (CSR 2023-24, 19-3-6/277)
240
-
-
Supplying and fixing 3 m 24 AWG multi stranded UTP patch cord with RJ-45 factory crimped connector of cat 6 type compliant ANSI/TIA-568.2-D standards in position as per specification no.WG-ELVC/PC (CSR 2023-24, 19-3-20/278)
100
-
-
Supplying, installing and testing UTP connector (RJ-45) as per specification no. WG-NAS/UTPC. (CSR 2023-24, 19-5-1/280)
10
-
-
Supplying and fixing 9U wall mount rack (Dimension-DxWxH – 500x550x480 mm) as per specification no. WG-NAS/RAK (CSR 2023-24, 19-5-19/281)
1
-
-
Supplying, fixing, and configuring 8-ports managed gigabit, layer-2 switch, 10/100/1000 base-T, PoE smart switch plus 2 SFP erected in provided rack compliant with IEEE 802.3 standards complete. (CSR 2023-24, 19-4-2/278)
1
-
-
Supplying and erecting PVC Surface modular switch box with double mounting plate for 4 module complete. (CSR 2023-24, 1-6-29/9)
4
-
-
Supplying and erecting PVC Surface modular switch box with double mounting plate for 6 module duly erected. (CSR 2023-24, 1-6-30/9)
6
-
-
Supplying, erecting, testing & commisioning GI sheet 0.8 mm (22 SWG) having zinc coating of 275 microns with galvanization process compliance to IS 2629:1985 to be used for fabrication of boxes panel boards etc. including cutting, bending, drilling, welding, riveting etc. and painting with one coat of red lead paint and 2 coats of enamel paint as per specification no. CP/SH/CR (CSR 2023-24, 6-1-3/89)
3
-
-
Supplying and erecting slotted angles, frames etc. for panel board or any other purposes complete with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the site engineer. (CSR 2023-24, 6-1-22/91)
30
-
-
Supplying and erecting LT CT multifunction DLMS compliance energy meter of accuracy of class 0.5, 3x240V, 50 Hz with optical & RS 232 port, backlit LCD, measures & displays trivector energy, load survey, TOD, tamper detection & logging, power ON /OFF events, instantaneous parameters of rating 1/5 A with display in absence of power complete with zero adjustment & test certificate from manufacturer erected on provided M.S. box and connected to CTs. (CSR 2023-24, 6-5-5/99)
1
-
-
Supplying, erecting, testing & commisioning LT current transformer with bar primary 50/5 to 1000/5 ratio with 15 VA burden erected in provided CRCA box duly secured with insulating materials connected to the meter with test certificates. (CSR 2023-24, 6-7-2/103)
3
-
-
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable, 1100 V 3½ core 150 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL (CSR 2023-24, 7-1-21/110)
20
-
-
Supplying , erecting & terminating XLPE insulated, galvanised steel formed wire armoured (strip) cable , 11 kV(E), 3 x 70 sq. mm. aluminium conductor laid in provided trench / pipe as per specification no. CB-HT (CSR 2023-24, 7-3-1/117)
60
-
-
Providing and erecting Heat shrinkable outdoor termination kit for 11 KV (E) XLPE HT cable 3 x up to 95 sq. mm. with necessary material as per specification No. CB-JT/HT (CSR 2023-24, 7-5-5/120)
2
-
-
Supplying & erecting G.I. pipe ‘A’ class 75 mm dia. for enclosing XLPE armoured cable on wall/pole as per specification no. CB-CE (CSR 2023-24, 7-6-4/122)
10
-
-
Supplying & laying (including excavation) reinforced cement concrete pipe of NP-2 class of 150 mm diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete. (CSR 2023-24, 7-6-5/122)
40
-
-
Supplying & erecting end pole D. P. Structure for 11/0.415 kV, 100 kVA Transformer with R.S.J. Pole 2 Nos. of size 100 x 116 mm x 11 Mtr. Long with suitable Distribution Box of C.R.C.A. Sheet 16 SWG with 4 Pole MCCB 200 Amps as incomer & 6 Nos.100 Amps Kitkat / MCCB for out going circuits. Transformer D.P. Structure includes the A. B. Switch 200 Amps, D.O. fuse Set & L.A. Set. 2 Nos.Top channel of size 100 mmx 50 mm for erection of A.B. Switch & 2 Nos. Base channel of size 100 mm x 50 x mm for erecting Transformer. Channel of size 75 x40 mm for erecting D.O. Fuse Set, L.A., A.B. Switch handle etc.Angle of size 50 x 50 x6 mm for erecting Distribution Box , Transformer Belt etc.as per drawing (min. 124 Kg. iron work ) with necessary clamps, Nut-bolts. V cross arm, top clip, insulators etc. complete with caution board & barbed wire. D.P. Structure shall be erected in c.c. foundation complete (CSR 2023-24, 8-3-25/135)
1
-
-
Supplying & erecting aviation obstruction light minimum up to 48 watt consisting of yellow painted die-cast aluminium alloy housing with integral LED aviation light comprising of aluminium housing with polycarbonate enclosure complete as per specification No. FG-AV. (CSR 2023-24, 2-8-1/25)
4
-
-
Kirloskar make Horizontal Centrifugal End Suction Pump KPD 65/13 (80 x 65mm) in Code '78' CF8 Impeller, with 15 KW/25HP/2900RPM TEFC IE-2 Motor with M.S.Fabricated Baseplate with Coupling with Coupling Guard Foundation Bolts. (100M3/HR @ 15Meter Head)
4
-
-
MSEDCL Liasoning Charges
1
-
-
The scope of work inculdes dredging of turning circle and approach channel as shown in the drawing or as directed by engineer incharge to a required dredge depth including an over dredge allowance 1m in all type of soil including sand, silt, clay or loose material and disposing them off at a designated location as shown in drawing with a minimum lead distance 10km or as directed by engineer incharge inclusive all equipments including dredging equipment, traansportation barge or any required equipments if any, fule, labour, machinery ect. all complete to handover the berth pocket ready for bearthing ships. The cost of providing survey equipment, consumables, spares ect and carrying out all survey including any aditional surveys, setting out, ect. and prepration of all records drawings for the purpose of execution of the contract for pre/initial and post/final survey from MMB Hydrographer are deemed to be included in lumpsum price quoted by the contractor. No additional payment will be payble to contractor in this regareds.
68305
-
-
The scope of work inculdes dredging of turning circle and approach channel as shown in the drawing or as directed by engineer incharge to a required dredge depth including an over dredge allowance 1m in all type of sub marine roack and disposing them off at a designated location as shown in drawing with a minimum lead distance 10km or as directed by engineer incharge inclusive all equipments including dredging equipment, traansportation barge or any required equipments if any, fule, labour, machinery ect. all complete to handover the berth pocket ready for bearthing ships. The cost of providing survey equipment, consumables, spares ect and carrying out all survey including any aditional surveys, setting out, ect. and prepration of all records drawings for the purpose of execution of the contract for pre/initial and post/final survey from MMB Hydrographer are deemed to be included in lumpsum price quoted by the contractor. No additional payment will be payble to contractor in this regareds.
3595
-
-
ROYALTY CHARGES AND TESRTING CHARGES.
-
-
-
Carrying out integrity test on piles of various diameters as per standard procedure and submitting reports.
110
-
-
Carrying out Initial Static Pile Load Testupto 2.50 times the design load on 1200mm vertical pile selected by Engineerin- charge as per the procedure and specifications laid down by IS:2911- Part 4 andmaintaining complete record of observations regarding load settlement etc. complete
2
-
-
Carrying out Initial Static Pile Load Testupto 2.50 times the design load on 1200mm vertical pile selected by Engineerin- charge as per the procedure and specifications laid down by IS:2911- Part 4 andmaintaining complete record of observations regarding load settlement etc. complete
5
-
-
Taking laboratory testing of concrete cubes and verious materials used during construction in District Vigilance & Quality Control Laboratory or as per approved Laboratory etc complete
-
-
-
A) Trap Metal/Rubble
-
-
-
i) Crushing Value/Compressive Strength, water
Absorption & Specific Gravity
1
-
-
B) For Concrete work
-
-
-
i) Concrete Mix Design (With all Tests on basic materials)
4
-
-
ii) Compressive Strength of C.C. Cube (Set of 3 Cubes)
146
-
-
C) For BASIC TEST OF CEMENT
-
-
-
Standard Consistancy, Fineness, Specific Gravity, Setting Time ( Initial & Final ), Compressive Strength, Soundness
2
-
-
D) BASIC TEST OF AGGREGATE
-
-
-
i) Water Absorption, Specific Gravity,Impact Value, Crushing Value
2
-
-
ii) Sieve Analysis
2
-
-
iii) Abrasion Value.
2
-
-
iv) Flakiness Index & Elongation Index
2
-
-
v) Soundness.
2
-
-
E) STEEL BAR TESTING
-
-
-
i) i) Upto 16 mm (Set of 3 Bars)
55
-
-
ii) Above 16 mm (Set of 3 Bars) (Tensile strength, %, Elongation, Yield Stress,Weight-Per Meter, Bend / Rebend Test, Proof Stress.)
55
-
-
Royalty Charges for Rubble, Murrum
-
-
-
Royalty Charges of Materials as Rubble Stone, Metal and Murum etc.
151.88
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements