Maharashtra Industrial Development Corporation Tender

... More
Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.

Maharashtra Industrial Development Corporation - MIDC Tender

Works
Civil And Construction
Water Storage And Supply
Eprocure
Opening Date18 Feb 2025
Closing Date4 Mar 2025
Tender Amount₹ 35,81,570 
Notes
Download

Costs

  • EMD

    ₹ 35,900
  • Document Cost

    ₹ 10,030
  • Tender Fee

    ₹ 500

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
item no.03 Providing Power Contactor 3 pole 400A MNX type AC3 Duty 240 V coil AC, 2 NO + 2 NC.

6

-

-

... More
item no.04 Providing Power Contactor 3 pole 300A MNX type AC3 Duty 240 V coil AC, 2 NO + 2 NC.

6

-

-

... More
item no.05 Providing Power Contactor 3 pole 250A MNX type AC3 Duty 240 V coil AC, 2 NO + 2 NC.

1

-

-

... More
item no.06 Providing Power Contactor 3 pole 140A MNX type AC3 Duty 240 V coil AC, 2 NO + 2 NC.

1

-

-

... More
item no.07 Providing Power Contactor 3 pole 70A MNX type AC3 Duty 240 V coil AC, 2 NO + 2 NC.

1

-

-

... More
item no.08 Providing Auxilary MXO-Contactor 22E Duty 240V coil AC 2 NO + 2 NC

21

-

-

... More
item no.09 Providing Motor Protection relay MPR D2, Range:2-5.5A, 230V AC, CTR-400/5A, Setting-3.12A.

11

-

-

... More
item no.10 Providing overload relay for motor starter Range6-10 Sec, Relay Range 20-33A.

11

-

-

... More
item no.11 Providing MN12 (CT operated) Thermal overload relay, Relay Range: 180 – 300A.

6

-

-

... More
item no.12 Providing Electronic timer ST 100, on Relay, Range 0.3 Sec-30 min, 240V AC/DC, Selected Range- 3 Min, Setting-30 sec.

11

-

-

... More
item no.13 Providing Current Sensor (S2CTS 1/5) (up to 3.00 H.P.) (5 Amp.)

6

-

-

... More
item no.14 Providing Add on Block D range contactor Rating 45A-80A, TA1-DN-22 2N0 + 2 NC 240 V Coil AC

11

-

-

... More
item no.15 Providing Push Button Illuminated Actuator, Flush (with BA9S Filament Bulb 130V) 220V AC with series resistor.

8

-

-

... More
item no.16 CSupplying, erecting, testing & commissioning LT current transformer with bar primary 50/5 to 1000/5 ratio with 15 VA burden erected in provided CRCA box duly secured with insulating materials connected to the meter with test certificates.

10

-

-

... More
item no.17 FCMA ELTEC SOFT STARTER Model SS1-150-OE-L1 50KW/ 200 HP / SS -415- 187KW/ 250HP (similar to existing design).

2

-

-

... More
item no.18 Providing & erecting 3 Pole MCCB 415V, 400A, rated short-circuit breaking capacity 36 kA (Ics=100% of Icu), adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/ UV/ trip alarm contact. MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in provided enclosure /panel as per specification no. SW-MCCB

6

-

-

... More
item no.19 Providing & erecting 3 Pole MCCB 415V, 250A, rated short-circuit breaking capacity 36 kA (Ics=100% of Icu) adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-MCCB

1

-

-

... More
item no.20 Providing & erecting 3 Pole MCCB, 415V, 160A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no lineload bias in provided enclosure/panel as per specification no. SW-MCCB

1

-

-

... More
item no. 21 Supplying, erecting & marking TP MCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-MCB

6

-

-

... More
itme no.22 Supplying, erecting & marking SP MCB 6A to 32A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-MCB

10

-

-

... More
item no.23 Supplying and erecting panel mounting type digital voltmeter having three and half digit LED display, calibrated for 0 to 750V AC suitable to operate on 500V having accuracy class of 0.5, AC supply with necessary PVC wire leads and lugs and mounting hardware on provided panel complete with calibration certificate from manufacturer.

6

-

-

... More
item no.24 Supplying and erecting static energy meter with 240V 50 Hz. AC supply 10 to 60 A, accuracy class 1.0 with backlit LCD display, (measuring and display kWh, kVAh, V,I,PF, frequency, kW, kVA, six months history of energy & MD in kW & kVA) with transparent hinge type box complete erected on polished teak wood board duly wired with required size of weatherproof PVC wires duly tested by electric supply company.

6

-

-

... More
item no. 25 Supplying and erecting panel mounting type digital ammeter having three and half digit LED display, external CT operated, calibrated for suitable to operate on 500V, 0 to 1000A having accuracy class of 0.5, AC supply with necessary PVC wire leads and lugs and mounting hardware on provided panel complete with calibration certificate from manufacturer.

6

-

-

... More
item no.26 Providing 315A TPN Switch Fuse Unit (CSSDF315B3N)

1

-

-

... More
item no.27 Providing 160A TPN Switch Fuse Unit (CSSDF160B3N)

1

-

-

... More
item no.28 Providing 125 A TPN Switch Fuse Unit (CSSDF125B3N)

2

-

-

... More
item no.29 Providing 100A TPN Switch Fuse Unit (CSSDF100B3N)

1

-

-

... More
item no.30 Providing 63 A TPN Switch Fuse Unit (CSSDF63B3N)

2

-

-

... More
item no.31 Providing 32 A TPN Switch Fuse Unit (CSSDF32B3N)

1

-

-

... More
item no.32 Providing HRC Fuse Link (DIN Type) 200 A (CSDFL1)

3

-

-

... More
item no.33 Providing HRC Fuse Link (DIN Type) 200 A (CSDFL1)

3

-

-

... More
item no.34 Providing HRC Fuse Link (DIN Type) 100 A (CSDFL00)

6

-

-

... More
item no. 35 Providing HRC Fuse Link (DIN Type) 32 to 63 A(CDFL00 & CSDFL00)

9

-

-

... More
item no. 36 Supplying & erecting LED type indicating pilot lamp with LED colours red / yellow / green, 230 / 250V on provided box / panel with necessary material, wiring & connections etc.

20

-

-

... More
item no.37 Supplying and erecting selector switch suitable for voltmeter/ammeter for 3 phase AC supply 500V, 50Hz, on provided box/panel and duly connecting with necessary PVC wire leads and lugs.

11

-

-

... More
sub estimate: Providing annual maintenance for LT control panels and starters at UDDS Dombivali. item no.01 Providing & erecting 4 Pole MCCB, 415V, 200A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-MCCB (Note:- 1)For use of 4 pole MCCBs in place of 3 pole MCCBs add 20% in rate of 3 pole MCCB.

1

-

-

... More
item no.02 Providing & erecting 4 Pole MCCB, 415V, up to 100A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for nstallation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-MCCB. (Note:1) For use of 4 pole MCCBs in place of 3 pole MCCBs add 20% in rate of 3 pole MCCB.

1

-

-

... More
item no.03 Providing & erecting 3 Pole MCCB, 415V, up to 100A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-MCCB

2

-

-

... More
item no.04 Supplying, erecting & marking TP MCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-MCB

8

-

-

... More
item no.05 Supplying, erecting & marking TP MCB 6A to 32A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-MCB

8

-

-

... More
item no.06 Supplying, erecting & marking SP MCB 6A to 32A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-MCB

4

-

-

... More
item no.07 Supplying, erecting & marking FP MCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-MCB

2

-

-

... More
item no.08 Providing Power Contactor 3 pole 205A, AC3 Duty 240 V coil AC, 1 NO + 1 NC.

4

-

-

... More
item no.09 Providing Power Contactor 3 pole 185A, AC3 Duty 240 V coil AC, 2 NO + 2 NC (LC1FDP185AE)

1

-

-

... More
item no.10 Providing Power Contactor 3 pole 80A, AC3 Duty 240 V coil AC, 1 NO + 1 NC (TC1-D8011)

1

-

-

... More
item no. 11 Providing Power Contactor 3 pole 32A MNX type AC3 Duty 240 V coil AC, 2 NO + 2 NC.

1

-

-

... More
item no.12 Providing Power Contactor 3 pole 25A MNX type AC3 Duty 240 V coil AC, 2 NO + 2 NC.

1

-

-

... More
item no.13 Providing Power Contactor 3 pole 25A MDX type AC3 Duty 240 V coil AC,1 NO

3

-

-

... More
item no.14 Providing overload relay for motor starter Range 6-10 Sec, Relay Range 65-105A (LR1F105)

3

-

-

... More
item no.15 Supplying and replacing thermal overload relay for motor starter 10 HP to 17.5 HP.

1

-

-

... More
item no.16 Providing Motor Protection relay MPR D2, Range:2-5.5A, 230V AC, CTR-200/5A, Setting-3.12A.

3

-

-

... More
item no.17 Supplying, erecting, testing & commisioning LT current transformer with bar primary 50/5 to 1000/5 ratio with 15 VA burden erected in provided CRCA box duly secured with insulating materials connected to the meter with test certificates.

3

-

-

... More
item no.18 Supplying & replacing electronic timer above 30 HP motor starter.

3

-

-

... More
item no.19 Providing timer 800SD-2-230, on Relay, Range 30 to 60 Sec, Change over 50/100ms, 2 C/O, 230V AC,

2

-

-

... More
item no.20 Supplying, installing, testing and commissioning air circuit breaker manual fixed type, non-drawout type, 650V, 630A, rated at 50º C without deration, 12kV Impulse, 4 pole (100% Neutral Protection), 50 kA (Ics=Icu=Icw for 1s), with standard accessories with ready to close, individual fault trip, alarm and trip indications, mechanical and electrical anti pumping, soft/hard rating plug (including hard rating plug CT) with Micro-processer based LCD display release with LSIG and temperature rise protection & with 4 C/O contacts for On-Off-Trip indication, min. 5 event and trip history on breaker display on provided iron frame as per specification no. SW-ACB

2

-

-

... More
item no.21 Providing 200A, 4P Switch Fuse Unit ( CSSDF200B4FN)

2

-

-

... More
item no. 22 Providing 100A, 4P Switch Fuse Unit (CSSDF100B4FN)

1

-

-

... More
item no.23 Providing 63 A TPN Switch Fuse Unit (CSSDF63B3N)

3

-

-

... More
item no.24 Providing 32 A TPN Switch Fuse Unit (CSSDF32B3N)

2

-

-

... More
item no.25 Providing HRC Fuse Link (DIN type) 200 A (CSDFL1)

6

-

-

... More
item no.26 Construction of chamber for 100mm sluices valve

3

-

-

... More
item no.27 Providing HRC Fuse Link (DIN type) 32 to 63 A (CDFL00 & CSDFL00 )

15

-

-

... More
item no.28 Push Button Illuminated Actuator, Flush (with BA9S Filament Bulb 130V) 220V AC with series resistor.

6

-

-

... More
item no.29 Supplying and erecting panel mounting type digital ammeter having three and half digit LED display, external CT operated, calibrated for suitable to operate on 500V, 0 to 1000A having accuracy class of 0.5, AC supply with necessary PVC wire leads and lugs and mounting hardware on provided panel complete with calibration certificate from manufacturer.

3

-

-

... More
item no 30 Supplying and erecting panel mounting type digital voltmeter having three and half digit LED display, calibrated for 0 to 750V AC suitable to operate on 500V having accuracy class of 0.5, AC supply with necessary PVC wire leads and lugs and mounting hardware on provided panel complete with calibration certificate from manufacturer.

3

-

-

... More
item no.31 Supplying and erecting static energy meter with 240V 50 Hz. AC supply 10 to 60 A, accuracy class 1.0 with backlit LCD display, (measuring and display kWh, kVAh, V,I,PF, frequency, kW, kVA, six months history of energy & MD in kW & kVA) with transparent hinge type box complete erected on polished teak wood board duly wired with required size of weatherproof PVC wires duly tested by electric supply company.

3

-

-

... More
item no.32 Supplying and erecting selector switch suitable for voltmeter/ammeter for 3 phase AC supply 500V, 50Hz, on provided box/panel and duly connecting with necessary PVC wire leads and lugs.

12

-

-

... More
item no.33 Supplying, erecting, testing & commisioning 525 V 3 phase, 50 Hz., MPP type capacitor having minimum overcurrent capacity of 1.8 In, peak inrush current capacity 300 In and minimum life 150000 hours kVAr bank of metalised polypropylene condensers (MPP) with the standard capacities of 2, 3, 5, 7, 10, 12.5 and 15 kVAr units of P.F. correction for operation on 3 phase 50 Hz. with externally discharging resistances, earthing terminals and built on angle iron or channel iron frame work and provided with terminal cover box complete erected on provided iron bracket or on floor duly tested by licensee.

70

-

-

... More
item no.34 LT - MCCBs (SW-MCCB) 34.1 Providing & erecting 3 Pole MCCB 415V, 400A, rated short-circuit breaking capacity 36 kA (Ics=100% of Icu), adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/ UV/ trip alarm contact. MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in provided enclosure /panel as per specification no. SW-MCCB

1

-

-

... More
34.2 Providing & erecting 3 Pole MCCB 415V, 250A, rated short-circuit breaking capacity 36 kA (Ics=100% of Icu) adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-MCCB

1

-

-

... More
34.3 Providing & erecting 3 Pole MCCB, 415V, 160A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-MCCB

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.