Mahanagar Telephone Nigam Limited Tender
Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.
Mahanagar Telephone Nigam Limited - MTNL Tender
Civil And Construction
Eprocure
Opening Date22 Nov 2024
Closing Soon2 Dec 2024
Tender Amount₹ 27,59,930
Costs
EMD
₹ 55,200Document Cost
₹ 590Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MTNL_836194_1Tender No
SM(E)Zone1and3/NIT/2024-25/31Tender Authority
Mahanagar Telephone Nigam Limited ViewPurchaser Address
-Website
http://http://mtnl.in/dis.htm
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
Servicing Overhauling and Testing of Eletrical Driven 15 HP Jockey Pump for Hydrant and sprinkler system with replacement of Gland packing & Defective gasket etc complete as required.
2
-
-
Servicing Overhauling and Testing of Eletrical Driven 10 HP Booster Pump Set with replacement of Gland packing & Defective gasket etc complete as required.
2
-
-
Servicing,Overhauling,repairing and testing of Fire Pump Eletrical control panel with replacement of minor defective spare parts i.e. Fuses, Indication lamp, manual push buttons, selector switches, electric voltmerer/ammeter and wiring etc complete as required.
1
-
-
Repairing,Servicing ,Overhauling and Testing of Existing courtyard Hydrant & Pumping System inside the pump room and at terrace including servicing of all Gate Valves,NRV,Hydrant Valve, ALL Fire inlets & Deluge valve with basement sprinkler network etc.(i/e Fault finding in existing hydrant system i/e arranging skilled staff for removing & checking of system testing & commissioning etc) complete as reqd.
1
-
-
Repairing,Servicing ,Overhauling and Testing of existing wet riser System including servicing of all Gate Valves, NRV,Hydrant Valve & Hose reel drum, Automatic Sprinkler network etc.(i/e Fault finding in existing hydrant system i/e arranging skilled staff for removing & checking of system testing & commissioning etc) complete as reqd.
4
-
-
Supplying, installing pressure gauge of 100mm dia,0-21 kg/cm2, fitted with 12/15 mm dia pad cock valve etc. complete as required
12
-
-
Supplying,installing,Testing and commissioning of pressure switch for working pressure of 7 kg/cm2 with 12/15 mm dia GI Nipple etc. complete as required
6
-
-
Supply and Fixing of 12 VDC / 150 AH battery with Conecting cable & terminal for Diesel Engin pump (Make :- Exide)
2
-
-
Supplying and installing 63 mm dia SS 304 Metal single outlet hydrant valves Morris pattern, oblique type confirming to IS:5290, II mark, with blank cap and chain etc complete as required.
6
-
-
Supplying S.S Branch pipe of 63 mm dia fitted with 19mm dia detachable hexagonal nozzle conforming to IS:903 ISI marked etc. complete as required.
44
-
-
Providing and installing in position 15m long and 63mm dia non-percolating RRL Fire Hose (as per IS 636) along with SS couplings, in existing wall mounted metal box etc complete.
88
-
-
Supply and installation of M.S Cabinet with glass and locking arrangement , suitable for 2 lengths of RRL hose and 1 no of Branch pipe, 2 coats of primer paint as per seven tank process and powder coated finally in post office red etc. of size 750mmx600mmx250mm complete as required.
6
-
-
SITC of Air release Valve with control valve
6
-
-
SITC of Existing Hydrant valve Mouth coupling with Lugs
8
-
-
SITC of 20mm diameter 30 meter long high pressure Thermoplastic reel as per IS:12585 tubing (I.S.I.marked) with PVC jet and spray type shutoff nozzle with 5mm diameter orifice suitable for existing hose reel drum complete as required.
30
-
-
Supply, Installation and Testing of Diesel Engine Pump Battery Charger 2 VDC / 10 Ampere Capacity SMPS type.
1
-
-
Providing and applying of two coat PO Red paint for all above ground existing fire hydrant & Sprinkler pipe line & Other accessoreies.
1
-
-
Supply & Fixing of suitable size GI Sheet canopy for Booster pump at tarace level.
2
-
-
Supply, Fabrication & Modification of existing hose reel drum connection from wet riser including nipple, 20 mm dia Brass ball vlave with hose nipple & Fittings
38
-
-
Supply of 25 mm dia GM gate valve with fittings
10
-
-
SITC of First-Aid-Fire Hose reel, wall mounted swinging type, complete with drum, bracket,25mm diameter MS Piping up to riser with 20mm diameter 30 meter long high pressure Thermoplastic reel as per IS:12585 tubing (I.S.I.marked) with PVC jet and spray type shutoff nozzle with 5mm diameter orifice complete as required. (This item is optionally, it will be used if required by department)
8
-
-
Above ground piping SITC of G.I.Pipe 'C' class with necessary fittings like Elbow, Tee, Reducer, Flange, Nipple, bend etc above ground of following sizes conforming to IS:1239 with one coat of red oxide primer and two coats of post office fire red enamel paint etc complete as required
-
-
-
a) 25 mm dia
12
-
-
b) 50 mm dia
12
-
-
c) 80 mm dia
24
-
-
d) 100 mm dia
6
-
-
e) 150 mm dia
240
-
-
Underground Piping SITC of 'C' class ERW G.I pipes with necessary fittings like Elbow, Tee, Reducer, Flange, Nipple,bend etc as per IS:1239-1973 with one coat of hessian and two coats of anti corrosive primer ( Black Japan) to be laid at a depth of 1 mtr. Below ground from pump house to ring main, ring main of wet risers etc. complete as required. ( Excluding of Civil work)
-
-
-
a) 150mm dia
60
-
-
b) 80mm dia
6
-
-
Foot Valve Supplying, installing and testing of C.I. Body Ball type Foot valve with strainer with nuts, bolts, gaskets, washers etc for negative suction etc. complete as required
-
-
-
a) 200mm dia
3
-
-
b) 150mm dia
1
-
-
c) 80 mm dia
2
-
-
SITC of four way fire Brigade Connection Supplying,installing,Testing and commissioning of one set of Siamese 150mm diameter instantaneous four way fire brigade inlet connection conforming to relevant IS , amended up to date, consisting of 63mm stainless steel Quadra plate, male inlet coupling with plug, cap& chain,gaskets,nuts,bolts and washers etc. complete as required
2
-
-
Excavation & refilling of trenches for underground pipeline, removing extra earth etc complete as required ( Soft soil/ earth)
20
-
-
Excavation & refilling of trenches for underground pipeline in RCC/ PCC/ Road/ Hard Morrow etc complete as required
6
-
-
Supplying and fixing M.S.tray / supports to pipes / angle frame for the pump foundation support from MS angles/ flat,channel, fabrication of M.S. priming tank as per requirement including cutting, bending, welding, painting with two coat of red oxide and one coat of enameled paint, grouting, fastening with suitable size of anchor fasteners on wall/ ceiling etc complete as reqd.
500
-
-
Supply & Fixing of 1000 liters 3 layers PVC body out door tank for Fire pump priming system with inlet/Out let fitiings (Make :- Sintex/Simplex /Plasto)
1
-
-
Supply, Installing &replacement of following size C.I ball/ Gate Valves confirming to IS:9890 or IS:778 screwed type of following sizes etc complete as required (This item is optionally, it will be used if required by department)
-
-
-
a) 80 mm dia
1
-
-
b)100 mm dia
1
-
-
c)150 mm dia
1
-
-
Supply, Installing &replacement of following size C.I Wafer type dual plate check valve/ NRV having S.S Hing & Stop Pin, design as per API 594 and comply with API 598 testing standard. With nut bolts, gaskets etc, complete as required.(This item is optionally, it will be used if required by department)
-
-
-
a) 50 mm dia
1
-
-
b) 80 mm dia
1
-
-
c)150 mm dia
1
-
-
Supply, Installing &replacement of following size cast iron wafer style butterfly valve confirming to IS 13095 ISI mark, having cast iron body lining black Nitrile/ Neoprene, disk of G.M/ IS 318, S.S.shaft IS 1570, with nut bolts, gaskets etc complete as required. (This item is optionally, it will be used if required by department)
-
-
-
a) 50 mm dia
1
-
-
b) 80 mm dia
1
-
-
c)100 mm dia
1
-
-
d)150 mm dia
1
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%