Jawaharlal Nehru Port Trust Tender

Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.

Jawaharlal Nehru Port Trust - JNPT Tender

Services
Solid Waste Management
Eprocure
Opening Date15 Jan 2020
Closing Date27 Jan 2020
Tender AmountRefer Documents 
Notes
Download

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Dismantling of existing common suction header, Supply, installation of pipe for common suction header, with all fittings, Gaskets, nut bolts,required supports, MOC- CI,Size- 300 mm

1

-

-

... More
Dismantling of existing pipe line from common suction header to suction of each pump, Supply, installation of pipe line from common suction header to suction of each pump, with all fittings, Gaskets, nut bolts,required supports, MOC- CI,Size- 200 mm

1

-

-

... More
Sluice Valves: Location: Between Common suction header and suction of each individual pumps Size: 200 mm MOC: CI Dismantling of Existing valve system, Supplying & Fixing of CI Resilient seated soft sealing sluice valve with body,bonnet of Cast Iron,Wedge fully rubber lined with EPDM & seals of NBR and the valves should be vaccum tight and 100% leak proof with face dimensions as per BS 5163-89/IS 14846-2000/DIN 3202 F4/F5. The rate is inclusive of cost of valve,bolts & nuts and rubber/Gasket insertions.

1

-

-

... More
Dismantling of existing pumping system, supply, installation of Raw water Transfer Pumps cum Filter Feed pumps - 5 Nos. (3W+2S), Each pump having capacity, 120 m3/hr @ 75 m head, Type- Horizontal Centrifugal Pump,

1

-

-

... More
Dismantling of existing discharge pipe line from each pump to common discharge header, Supply, installation of pipe line from common suction header to suction of each pump, with all fittings, Gaskets, nut bolts,required supports, MOC- CI,Size- 200 mm

1

-

-

... More
Dismantling of existing Discharge header, Supply, installation of pipe for common discharge header, with all fittings, Gaskets, nut bolts,required supports, MOC- CI,Size- 300 mm

1

-

-

... More
Dismantling of existing pipeline from common dischage header to filtration system in Pump house only, Supply, installation of pipeline from common dischage header to filtration system in Pump house only, with all fittings, Gaskets, nut bolts,required supports, MOC- CI,Size- 200 mm

1

-

-

... More
Sluice Valves: Location: Between discharge line of each individual pumps to Common discharge header. Size: 200 mm MOC: CI Dismantling of Existing valve system, Supplying & Fixing of CI Resilient seated soft sealing sluice valve with body,bonnet of Cast Iron,Wedge fully rubber lined with EPDM & seals of NBR and the valves should be vaccum tight and 100% leak proof with face dimensions as per BS 5163-89/IS 14846-2000/DIN 3202 F4/F5. The rate is inclusive of cost of valve,bolts & nuts and rubber/Gasket insertions

1

-

-

... More
Sluice Valves: Location: On common Discharge header Size: 300 mm MOC: CI Dismantling of Existing valve system, Supplying & Fixing of CI Resilient seated soft sealing sluice valve with body,bonnet of Cast Iron,Wedge fully rubber lined with EPDM & seals of NBR and the valves should be vaccum tight and 100% leak proof with face dimensions as per BS 5163-89/IS 14846-2000/DIN 3202 F4/F5. The rate is inclusive of cost of valve,bolts & nuts and rubber/Gasket insertions.

1

-

-

... More
Sluice Valves: Location: Between common discharge header to Discharge Line in Pump house. Size: 200 mm MOC: CI Dismantling of Existing valve system, Supplying & Fixing of CI Resilient seated soft sealing sluice valve with body,bonnet of Cast Iron,Wedge fully rubber lined with EPDM & seals of NBR and the valves should be vaccum tight and 100% leak proof with face dimensions as per BS 5163-89/IS 14846-2000/DIN 3202 F4/F5. The rate is inclusive of cost of valve,bolts & nuts and rubber/Gasket insertions.

1

-

-

... More
NRV: Location: Between discharge line of each individual pumps to Common discharge header. Size: 200 mm MOC: CI Dismantling of Existing valve system, Supplying & Fixing of NRV, PN 16. The rate is inclusive of cost of valve,bolts & nuts and rubber/Gasket insertions.

1

-

-

... More
Butter Fly Valves: Location: between Disharge line in pump house to common Inlet pipe header of filttration system- Pressure sand filter . Size: 200 mm MOC: CI Dismantling of Existing valve system, Supplying & Fixing of Butterfly Valves, PN 16. The rate is inclusive of cost of valve,bolts & nuts and rubber/Gasket insertions.

1

-

-

... More
Level meter at GSR, height 2.5 m

1

-

-

... More
Elevated Storage Reservoir

-

-

-

... More
Sluice Valves: Location: On Incoming lines to ESR Size: 300 mm MOC: CI Dismantling of Existing valve system, Supplying & Fixing of CI Resilient seated soft sealing sluice valve with body, bonnet of Cast Iron, Wedge fully rubber lined with EPDM & seals of NBR and the valves should be vaccum tight and 100% leak proof with face dimensions as per BS 5163-89/IS 14846-2000/DIN 3202 F4/F5. The rate is inclusive of cost of valve,bolts & nuts and rubber/Gasket insertions.

1

-

-

... More
Dismantling of existing 30 m pipe, Supply, installation of Horizontal Tail pipe, with all fittings, Gaskets, required supports, nut bolts, MOC- CI,Size- 300 mm

1

-

-

... More
Dismantling of existing oveflow pipe system, Supply, installation of overflow pipe, with all fittings, Gaskets, nut bolts, required supports, MOC- CI,Size- 300 mm

1

-

-

... More
Dismantling of existing vertical tail pipe system, Supply, installation of vertical tail pipe, with all fittings, Gaskets, nut bolts,required supports, MOC- CI,Size- 200 mm

1

-

-

... More
Level meter at ESR, height 6 m

1

-

-

... More
Filtration System

-

-

-

... More
Supply, installation & testing and commissioning of vertical floor mounted mild steel Epoxy pressure type Pressure Sand filter of suitable size for required flow and head, provided with an inlet distributor. The vessel is painted externally and internally with epoxy paint with primer with frontal piping & valves, back wash system & filter media etc. complete with standard fittings like cover, pressure gauge at inlet & outlet, sampling cock, rinse drain valve, air vent valve with piping, bolts, nuts & rubber gaskets. (1 Set) Filtration Rate- Max. 15-17 m3/m2/hr Flow rate =120 M3 / hr Vessel Dia = 3000 mm HOS = Min. 2300 mm Shell / Dish thickness = 12/ 14 mm Working pressure = 5.0 Kg/Sq.cm. Test pressure = 10.5 Kg/Sq.cm.

1

-

-

... More
Dismantling existing Filtration System

-

-

-

... More
Dismantling existing Filtration System with sand media of vertical floor mounted mild steel Epoxy pressure type Pressure Sand filter,charges tranfering the all vessels and waste filtration media to srap yard in vendors scope Vessel MOC = MS Vessel Dia = 3000 mm HOS = Min. 2000 mm

1

-

-

... More
Foundation civil work for Filtration System

-

-

-

... More
Dismantling of existing civil founadtion work of existing Pressure Sand filters and new foundation work for new filtration system of suitable size with out disturbing of working sand filters(as per approved foundation load and drawings), MS Vessels details are as follows Flow rate =150 M3 / hr Vessel Dia = 3000 mm HOS = Min. 2300 mm Shell / Dish thickness = 12/ 14 mm Working pressure = 3.5 Kg/Sq.cm. Test pressure = 5.5 Kg/Sq.cm.

1

-

-

... More
Sodium Hypochlorite dosing system: Dosing Tank- 500 lit. Sintex Dosing Pumps - Metering Type- (1W+1S) MOC - PP, Capacity - 50 lph @ 4 bar, make - milton roy

1

-

-

... More
4 year comprehensive AMC for water filter after defect liability period of 1 year (excluding replacement of pipeline). Including - 1) repairing and maintenance of all valves with replacement if required, 2) repairing and maintenance of all NRV with replacement if required, 3) repairing and maintenance of all Pumps and motors with replacement if required,4) replacement of media 3 times with in 5 years AMC (once in 1.5 years), 5) replacement of all gaskets and GI nut bolt at the time of each servicing(at the time of media replacement), 6) replacement of level indicator, sensors and meters if required. 7) repairing and maintenance of all MCC control panel with replacement of electrical parts if required 8) Regular vendors executive visit once in month for checking of water analysis parameters, performance of filtration system, leakage checking if any.(Total visits 60 Nos)

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.