Inter University Centre For Astronomy And Astrophysics Tender
... More
Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.
Inter University Centre For Astronomy And Astrophysics - IUCAA Tender
Electrical and Electronics
Eprocure
Opening Date14 Feb 2025
Closing DateCancelled
Tender AmountRefer Documents
Costs
EMD
₹ 34,600Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_IUCAA_849286_1Bid Award Id
ViewTender No
M24-0779Tender Authority
Inter University Centre For Astronomy And Astrophysics ViewPurchaser Address
-Website
http://https://www.iucaa.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
MS structural work structure for condensing units, Powder Coated
20
-
-
... More
Core cutting in wall/slab/Beam for AC piping
150
-
-
... More
Supplying, laying / fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 15.9 mm dia (OD) for liquid line/suction line supply and return piping of 18 gauge (copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19mm thick elastomeric nitrile rubber along with application of multicoating of refrigerant piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations with OEM standards of refrigerant air conditioning system complete.
85
-
-
... More
Supplying, installing, testing & commissioning split type variable speed inverter technology with with DC Rotory Inverter Compressor. room air conditioning unit 2 TR capacity suitable to operate on 220-240 V, 50 Hz, A.C. supply having 1 no of air handling unit hi-wall type complete with refrigerant R32/R410 having copper condenser, minimum 2.5PM filter, self diagnosis feature, stabilizer free operation & temperature display on indoor unit, noise level maximum 47dBA at position. The minimum acceptable value of ISEER Value of the offered Split AC model shall be not less than 5.05 for 2 TR on 100% laod. The ISEER value confirmation should be done by the OEM on their authentic letter head. Condensing unit with reputed make hermetically sealed rotary inverter compressor, air cooled condenser with copper tubes, extended aluminum fins and condenser fan with adequate air flow capacity suitable for operation at ambient temp. of 45 deg C. Indoor unit consisting of 3/4 row-cooling coil blower with motor, filters, drain pan & casing. The evaporator shall be complete with expansion valve & distributor. The outdoor unit shall be factory tested and filled with first charge of refrigerant R-32/R-410A before delivering at site. The units shall be with individual cordless remote.
16
-
-
... More
Supplying, laying / fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 9.5 mm dia (OD) for liquid line/suction line supply and return piping of 18 gauge (copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19mm thick elastomeric nitrile rubber along with application of multicoating of refrigerant piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations with OEM standards of refrigerant air conditioning system complete
32
-
-
... More
Supplying, laying / fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 6.4 mm dia (OD) for liquid line/suction line supply and return piping of 18 gauge (copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19mm thick elastomeric nitrile rubber along with application of multicoating of refrigerant piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations with OEM standards of refrigerant air conditioning system complete.
32
-
-
... More
Supplying, installing, testing & commissioning split type variable speed inverter technology with DC Rotory Inverter Compressor, room air conditioning unit 1.5 TR capacity suitable to operate on 220-240 V, 50 Hz, A.C. supply having 1 no of air handling unit hi-wall type complete with refrigerant R32/R410 having copper condenser, minimum 2.5PM filter, self diagnosis feature, stabilizer free operation & temperature display on indoor unit, noise level maximum 45dBA at position. The minimum acceptable value of ISEER Value of the offered Split AC model shall be not less than 5.12 for 1.5 TR on 100% laod. The ISEER value confirmation should be done by the OEM on their authentic letter head. Condensing unit with reputed make hermetically sealed rotary inverter compressor, air cooled condenser with copper Tubes, extended aluminum fins and condenser fan with adequate air flow capacity suitable for operation at ambient temp. of 45 deg C. Indoor unit consisting of 3/4 row-cooling coil blower with motor, filters, drain pan & casing. The evaporator shall be complete with expansion valve & distributor. The outdoor unit shall be factory tested and filled with first charge of refrigerant R-32/R-410A before delivering at site. The units shall be with individual cordless remote.
4
-
-
... More
Drain piping in UPVC with all fittings, supports and clamps upto 20/25 mm dia. including drilling hole in wall chipping wall etc to conceal and to route drain pipe.
92
-
-