Indian Railways Institute Of Electrical Engineering Tender

Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.

Indian Railways Institute Of Electrical Engineering - IRIEEN Tender

Works
Civil And Construction
Civil Works Others
Excavation
Ireps
Opening Date27 Mar 2024
Closing Date22 Apr 2024
Tender Amount₹ 49,92,766.27 
Notes
Download

Costs

Summary

Provision Of Gymnasium Building At Irieen.

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
5.1) Providing and laying in position specified grade of reinforced cement concrete, excluding the 7 cost of centering, shuttering, finishing and reinforcement - All work up to plinth level: (5.1.2) 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III)derived from natural sources : 3 graded stone aggregate 20 mm nominal size)derived from natural sources

39

8364

251503.13

... More
5.3) Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° 9 landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III)derived from natural sources : 3 graded stone aggregate 20 mm nominal size)derived from natural sources.

60

10391

480706.16

... More
5.22A) Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. (5.22A.6) Thermo-Mechanically Treated bars of grade Fe- 500D or more.

7508

89

518954.09

... More
11.41 A) Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by 12 the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @ 3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only .Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. Glazed vitrified tiles Matt/Antiskid finish of size (11.41A3.2) Size of Tile 600x1200 mm

88

1612

109421.86

... More
11.55) Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm 15 thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge: (11.55.1) Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.

54

2589

107827.9

... More
5.9) Centering and shuttering including strutting, propping etc. and removal of form for: (5.9.1) Foundations, footings, bases of columns, etc. for mass concrete 19 198.00 Sqm 766.55 151776.90 (-) 22.90 117019.99

88

332

22532.32

... More
5.9.6) Columns, Pillars, Piers, Abutments, Posts and Struts

228

804

141377.5

... More
21.1) Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling 22 up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately): (21.1.1) For fixed portion. (21.1.1.2) Powder coated aluminium (minimum thickness of powder coating 50 micron)

210

466

75498.63

... More
21.1.2) For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots 25 and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately). (21.1.2.2) Powder coated aluminium (minimum thickness of powder coating 50 micron)

32

553

13657.19

... More
12.45) Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm 27 dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification andalso including the cost of making openings for light fittings, grills,diffusers, cutouts made with frame of perimeter channels suitablyfixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with: (12.45.2) 12.5 mm thick tapered edge Glass Reinforced Gypsum (GRG) board conforming to IS: 2095- (Part 3) : 1996 (Board with BIS certification marks)

178

1286

176549.83

... More
18.8) Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for29 hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls, etc. (18.8.2) 20 mm nominal outer dia Pipes 31 25.00 Metre 624.70 15617.50 (-) 22.90 12041.09

9

512

3555.54

... More
18.8.3) 25 mm nominal outer dia Pipes

25

624

12041.09

... More
18.53) Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 (18.53.1) 15mm nominal bore

4

500

1543.08

... More
21.3) Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. 34 with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge. (Cost of aluminium snap beading shall be paid in basic item): (21.3.3) With float glass panes of 8 mm thickness (weight not less than 20 kg/sqm)

66

1496

76133.09

... More
21.4) Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and 36 door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge. (21.4.1) With stainless steel cover plate minimum 1.25 mm thickness

3

2448

5664.19

... More
21.18) Providing and fixing 12 mm thick frameless toughened glass door shutter of approved 38 brand and manufacture, including providing and fixing top & bottom pivot & double action hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-incharge (Door handle, lock and stopper etc.to be paid separately).

6

4540

21005.28

... More
10.28) Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the 39 same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners, etc.

55

612

25962.46

... More
17.2) Providing and fixing white vitreous china pedestal type water closet (European type W.C. 40 pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required. (17.2.1) W.C. pan with ISI marked white solid plastic seat and lid.

2

5540

8543.45

... More
18.49) Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931: (18.49.1) 15 mm nominal bore

2

434

669.54

... More
17.7) Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. 44 brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: (17.7.3) White Vitreous China Wash basin size 550x400 mm with a pair of 15 mm C.P. brass pillar taps

4

2040

6293.98

... More
6.13) Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. (6.13.2) Cement mortar 1:4 (1 cement :4 coarse sand)

50

1018

39245.83

... More
6.4) Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in: (6.4.1) Cement mortar 1:4 (1 cement : 4 coarse sand) 51 750.00 Sqm 307.25 230437.50 (-) 22.90 177667.31

38

8512

249387.51

... More
13.4) 12 mm cement plaster of mix: (13.4.1) 1:4 (1 cement: 4 coarse sand

750

307

177667.31

... More
13.7) 12 mm cement plaster finished with a floating coat of neat cement of mix: (13.7.1) 1:3 (1 cement: 3 fine sand)

4.48

374

1292.34

... More
12.41) Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. (12.41.1) 75mm diameter 56 60.00 Metre 319.75 19185.00 (-) 22.90 14791.64

6

213

985.34

... More
12.41.2) 110 mm diameter

60

319

14791.64

... More
12.43) Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC 57 rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. (12.43.2) 110 mm

32

310

7669.29

... More
11.49 A) Providing and laying full body vitified tile in floor of minimum thickness of 15 mmwith water absorption less than 0.06% and confirming to IS 15622 of approved make brand and manufacturer, laid on 59 20mm thick base cement mortar 1:4 (1 cement :4 coarse sand )jointing with grey cement slurry @ 3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The slab must be cut with the zero chipping dimond cutter only. Laying of slab will be done with the help of notch trowel wedge, clips of required thickness. Vacuum cups for lifting, levelling system and rubber mallet for placing the slab gently and easily. Size of tile 800 x 2400 mm of all colour and shades

6

3296

15247.76

... More
18.21) Providing and fixing uplasticised PVC connection pipe with brass unions: (18.21.2) 45cm length (18.21.2.1) 15mm nominal bore 64 67.00 Sqm 4679.35 313516.45 (-) 22.90 241721.18

6

85

393.9

... More
8.2.2) Granite stone slab of colour black, Cherry/Ruby red (8.2.2.1) Area of slab upto 0.50 sqm

67

4679

241721.18

... More
8.2.3) Granite stone slab of all colour and texture except black, Cherry/Ruby red (8.2.3.2) Area of slab over 0.50 sqm

155

3301

394545.76

... More
6.1) Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: (6.1.1) Cement mortar 1:4 (1 cement : 4 coarse sand)

2.2

6882

11673.25

... More
13.26) Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete.

437

214

72203.46

... More
13.48) Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: (13.48.1) Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of Special primer applied @ 0.75 ltr /10 sqm 73 38.00 cum 1937.60 73628.80 (-) 22.90 56767.80

650

158

79657.79

... More
16.3) Supplying and stacking at site. (16.3.1) 90 mm to 45 mm size stone aggregate

38

1937

56767.8

... More
1.10) Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC 1 insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. 1.10.3 Group C

30

1467

32118.5

... More
1.11) Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor 2 single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.

4

1562

4559.79

... More
1.12) Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.

132

334

32175.42

... More
1.14) Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 1.14.2 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire 5 50.00 Metre 334.00 16700.00 (-) 27.02 12187.66

40

275

8027.8

... More
1.14.5) 2 X 10 sq. mm + 1 X 6 sq. mm earth wire

110

570

45758.46

... More
2.4) Supply and Fixing following way , horizontal type three pole and neutral , Sheet steel , MCB 7 distribution Board , 415 Volt, on surface /recess , complete with tinned copper bus bar, neutral Bus bar, Earth bus bar, DIN bar, interconnetion powder painted including earthing, etc. as required (But without MCB /RCCB /Isolator) (2.4.1) 4 way ( 4 + 12 ), double door

1

-

2985.61

... More
2.10) Supplying and fixing 5A to 32 A rating, 240/415 V, 10 kA, "C" curve (or "B" curve), miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connection, testing and commissioning etc.as required. (2.10.3) Double pole 11 1.00 Each 1007.00 1007.00 (-) 27.02 734.91

10

656

4787.49

... More
2.10.4) Triple pole

1

-

734.91

... More
2.5) Suppling and fixing of following ways surface / recesed mounting vertical type 415 TPNMCB 12 distribution board off sheet steel /dust protected duly powder painted inclusive of 200 AMP TIN copper bus bar common neutral link/earth bar/ DIN bar for mounting MCB. but without MCB,s and incomer ( Note - Vertical type MCB TPDB is normally used where three phase out lets are required ) 2.5.1 ( 4+12 ), Double door

1

-

5482.26

... More
2.2) Providing and fixing following rating & breaking capacity and pole MCCB with thermomagntic release and terminal spreaders in existing cubical pannel board including drilling holes in cubical connections, etc. as required 2.2.1 100A, 10 KA, TPMCCB

1

-

2756.45

... More
5.2) Earthing with G.I . Earth pipe 4.5 mtrs Long, 40 mm dia including accessories, and providing masonry encloser with cover plate having locking arrangement and watering pipe, etc. with corcoal / coke and salt as required.

1

-

5002.78

... More
NS-1 A) Supply, fixing ,testing and commissioning of LED light fitting Recess/ surface mounted of 240 V , AC 15 Watt LED Indoor fitting similar to Havells Fazer Neo 3 in 1or as approved by consignee

100

1150

83927

... More
NS-1 B) Supply fixing testing and commissioning of LED light fitting Recess/ surface mounted of 240 V , AC, 24- 40 Watt LED Indoor fitting 2 feet x 2 feet similar to Crompton POLARIS NIO -I or as approved by consignee.

16

4500

52545.6

... More
NS-1) Supply of Copper pipes 3/8" and 3/4",Insulation and Cable and Drain pipe for AC installation (including GST) [Unit for this item is Running ft.]

150

750

111937.5

... More
NS-2) Supply testing and commissioning of Air conditioner Star rated, Make - Voltas, Diakin, Mistubhishi, Blue star or as approved by consignee. [Rates are based on budgetary quotation including GST] (Unit for this item: Tonne)

12

55000

660000



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.