Indian Oil Corporation Limited Tender

... More
Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.

Indian Oil Corporation Limited - IOCL Tender

Works
Software and IT Solutions
Eprocure
Opening Date26 Mar 2024
Closing Date20 Jun 2024
Tender Amount₹ 64,71,98,372 
This is an estimated amount, exact amount may vary.
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
For mounting of Redundant ACS cum photopass management Server along with associated rack mounted monitors, rack mounted keyboard, mouse, 4 port industrial grade KVM switches, power adapters, networking components, MCBs etc as per specification and tender document.

1

6266

-

... More
Supply of 25W weather proof Horn type Speaker and mounting accessories etc complete as per specifications and Tender Document. Type : Pole Mountable, suitable for speech and music reproduction Rated power : 25 W Frequency range : 20 Hz TO 20 KHz Ingress protection : Min. IP 65, Standard : EN 60065

7

168338

-

... More
Supply of Wall mounted/wheel mounted Network Rack-minimum 9U 19" Rack for mounting of Terminal Server/Ethernet switches/LIU/ OFC components along with accessories like power sockets, MCBs, fan, mounting accessories etc complete in all respective at (i) Main Gate Security Room, (ii) Security room near Invoice Room, (iii) TT crew rest room

3

129397

-

... More
At Main Gate Security Room- copper ports of 10/100/1000 MBPS [Control LAN - 2 nos.,CCTV - 2 no.] (Minimum 8 nos. copper ports and 2 nos. optical ports)

4

12503

-

... More
Installation, integration, configuration, testing and commissioning of outdoor weatherproof housing (IP 65 or better) suitable for installing Layer 2 switch, PSU, LIU and adaptor for Ethernet switch/media convertor surge protectors and other accessories of PA Paging System. The scope also includes supply of blinding plugs, LIU, OFC accessories, double compression cable glands etc as per specifications and Tender Document.

7

30677

-

... More
2P x 1.5 sqmm

10330

1755273

-

... More
3C x 4 sqmm

6100

1288442

-

... More
Supply of vapour recovery arm of size 80 mm NB having 3” (80 NB) with poppeted vapour coupler, break away coupler, NRV, flame arrestor, reducers, mounting structures, parking stand with compatible API adaptor, associated accessories, mounting structure etc complete as per specifications and tender document. Application : MS

4

1448284

-

... More
Installation, integration, testing and commissioning of half man height dual lane Uni-directional turnstile (tripod) with controller along with accessories, mounting structure, pressure sensor etc required as per standard design engineering, specification and tender document complete in all respect. (Location : At security entry gate -1 SET., security exit gate - 1 SET)

2

23255

-

... More
Supply of Wall mounted/wheel mounted Network Rack-minimum 9U 19" Rack for mounting of Ethernet switches/LIU/ OFC components along with accessories like power sockets, MCBs, fan, mounting accessories etc complete in all respective at (i) Main Gate Security Room, (ii) Security room near Invoice Room, (ii) Invoice Room, (iv) Control Room for TAS equipments. Supply of required OFC components & accessories like LIU, splice trays, loaded adaptor, blank plates, UTP cables, Fibre patch cords, pigtails, tags, ties, Ethernet cable with RJ45 connector etc complete in all respect for functioning of CCTV camera.

4

172530

-

... More
3C x 2.5 sqmm

27000

3823200

-

... More
MS - 1.6 KL

1

862251

-

... More
Make up water Pump Suction and Discharge end

2

95886

-

... More
Supply of Resistance - Capacitance type Tank Truck grounding unit along with display for resistance, capacitance values and accessories like 3 nos. of heavy duty flexible coiled cables with high quality rugged, heavy duty SS/ brass grounding socket, FLP double compression glands, Ex-Plug, mounting structure etc, complete as per specification and tender documents. (2 nos. of coiled cable with socket for TT earthing relay interlocks and 1 no. for separate earthing of TT)

6

391623

-

... More
For Xtragreen

1

15960

-

... More
Supply of Master Control Station for control room at Console Desk: • Modular design providing individual design and configuration of the device • Telephone set module with a handset, build‐in speaker and microphone for duplex twoway communication • Call station module for duplex and simplex communication • Up to 3 extension modules (42‐126 keys) • Hands‐free communication • Gooseneck microphone with optical «on‐off» indication • Easy maintenance and configuration by control keys and display • Volume Setting • Hot swapping • Color TFT display • Button labeling (transparent buttons) • LED indications for incoming, missed call and line status (busy)

1

262258

-

... More
Installation, Integration, Testing and Commissioning of Microprocessor based Coriolis mass flow meter for white oil (Ethanol) application alongwith display unit and mounting accessories with adjustable screw support, reducer (if required) etc for line size 2" suitable for maximum flowrate of 500 LPM complete as per specifications and tender document for ethanol blending. Note: In case MFM is not having inbuilt ASTM table, vendor has to supply Flow Computers along with accessories as per tender document at no adddtional cost to IOCL .

4

19564

-

... More
48C x 1.5 sqmm

6200

490172

-

... More
4C x 1.5 sqmm

1200

43896

-

... More
Ex-proof and weather proof MCP

30

52179

-

... More
Installation, configuration, integration, testing and commissioning of 4 port Industrial grade layer 2 Managed POE based Ethernet Switch for connecting Cameras with 4 Nos. RJ copper port and 2 Nos. optical fibre ports with inbuilt/external surge protector (Type 1+2) at the input power supply as per specifications and Tender Document.

55

215727

-

... More
16 ports at Control Room

2

570704

-

... More
Supply of redundant TAS Management Server (Rack type mountable in 19" rack ) along with 1 no. rack type (1U) LED monitor of minimum size of 19" suitable for 24x7 operation along with High availability redundancy software working on redundant (Primary and Secondary) hot standby mode , keyboard drawer, optical mouse and combo 4 port KVM switch, OS, Antivirus, SQL, oracle, RDBMS (license copy) etc complete as per specifications and Tender Document. OR Supply of Dual Mode Redundant Grade with built in redundancy TAS Management Server (Rack type mountable in 19" rack ) along with 1 no. rack type (1U) LED monitor of minimum size of 19" suitable for 24x7 operation, keyboard drawer, optical mouse and combo 4 port KVM switch, OS, Antivirus, SQL, oracle, RDBMS (license copy) etc complete as per specifications and Tender Document. TAS Management Servers (TAS-MS) shall have either of the above mentioned configuration meeting the complete specification and tender requirements. In addition, the TAS-MS shall be configured to have Zero Downtime to repair, Full data redundancy shall be provided using proven technology , it shall also provide port level redundancy.The system solution shall be capable of self fault detection and isolation, all necessary hardware/software configuration etc to achieve the same shall be included.

1

1705871

-

... More
License area Entry barrier gates (Near invoice room - 2 no. X2)

4

218257

-

... More
Installation, integration, configuration, testing and commissioning of layer 3 managed gigabit Ethernet switch with minimum 24 ports or as per site requirement whichever is higher along with SFP, copper, fibre modules, accessories complete as per specifications and tender documents for Plant Communication & EPBAX system.

2

49276

-

... More
Installation,integration,testing and commissioning of Auto Tank Gauging (ATG) probe combo with density measurement (Wireless or Wired) including necessary accessories as per Tender specifications.

-

-

-

... More
Installation, configuration, integration, testing and commissioning of HD IP PTZ Camera (2MP) along with power supply unit (POE based) with POE injector (industrial grade),with inbuilt/external surge protection unit and mounting accessories etc complete as per specifications and Tender Document.

49

249493

-

... More
12 M pole with/without cantilever arrangement

1

19335

-

... More
Supply of Mobile Master meter (Master MFM) proving system for line size 50mm consisting of Master Mass flow meter with display unit, Master Temperature Transmitter with RTD with Thermo-well, Mounting accessories suitable for installation on 2" line size, 2 nos. isolation ball valve of 50 mm, Two number swivel joints on ends,hose pipe, trolley mounted Master Meter Skid with suitable wheels, FLP JB, FLP double compression glands, power & signal adapter along with accessories for Master Meter, FRLS Copper Power & Signal Cable (Retractable Type) of minimum 10 m or as per site requirement with compatible FLP plugs for MFM along with integration of Mobile Master MFM with TAS and integration of temperature transmitter with Master MFM, supports for mounting the equipments, pipes, flanges, reducers, gaskets, nuts, SS bolts & studs etc complete as per specification and tender document.

1

1284654

-

... More
1T x 1.5 sqmm

300

45312

-

... More
24 ports - Admin Building (2 Nos)

2

378147

-

... More
For Cone Roof Vertical tanks (Primary and Secondary Radar Gauges )

-

-

-

... More
2C x 1.5 sqmm

8600

791544

-

... More
Installation, configuration, integration, testing and commissioning of Laser printer (Monochrome) for Visitor pass printing having flexibility to print on A4, A5, A6 paper complete as per specification and tender document.

1

2515

-

... More
4C x 4 sqmm

100

4838

-

... More
Installation, integration, testing and commissioning of flameproof cum weather proof, Temperature transmitter along with display unit, RTD, Thermowell for line size 100mm, mounting accessories etc complete as per specifications and tender document.

4

13286

-

... More
19" Rack type at Control Room, form factor - Rack, CPU height - 2U (1 no.)

1

4417

-

... More
SERVICE COMPONENTS

-

-

-

... More
48C x 1.5 sqmm

6200

6957516

-

... More
19" Rack type at Control Room, form factor - Rack, CPU height - 2U

1

416691

-

... More
4P x 1.5 sqmm

9500

358720

-

... More
Open path type Infrared detector (0-90m) along with alignment telescope, configuration & testing kit etc (Tentative location: .) MS tanks covering ROSOVs and outside dyke also - 8 nos

8

6015621

-

... More
8C x 1.5 sqmm

100

25134

-

... More
For mounting of TAS Management Servers along with associated rack mounted monitors, rack mounted keyboard, mouse, 4 port industrial grade KVM switches, power adapters, networking & OFC components, Ethernet switch, GSM modems, MCBs etc as per specification and tender document.

1

6266

-

... More
Supply of rack mounted CCTV Server (s) along with rack type monitor, optical mouse and combo 4 port KVM switch, OS, Antivirus, LIU etc complete as per specifications and Tender Document. Note: In case multiple servers are required to meet the tender requirement, vendor to provide the same at no additional cost to IOCL. In additional to above, Vendor to provide failover server to have redundancy in CCTV server such that failure of one server should not affect the CCTV operation and recording at its full resolution at no additional cost to IOCL.

1

999037

-

... More
IS Detector

5

174185

-

... More
Automatic Fire Detection and Alarm System

-

-

-

... More
HSD - 1.6 KL

1

862251

-

... More
For Secondary Radar Gauges installed on A/G product tanks

1

4624

-

... More
Installation of Wall mounted/wheel mounted Network Rack-minimum 9U 19" Rack for mounting of Ethernet switches/LIU/ OFC components along with accessories like power sockets, MCBs, fan, mounting accessories etc complete in all respective at (i) Main Gate Security Room, (ii) Security room near Invoice Room, (ii) Invoice Room, (iv) Control Room for TAS equipments. Supply of required OFC components & accessories like LIU, splice trays, loaded adaptor, blank plates, UTP cables, Fibre patch cords, pigtails, tags, ties, Ethernet cable with RJ45 connector etc complete in all respect for functioning of CCTV camera.

4

16203

-

25

45430

-

... More
Supply of IP Fixed Bullet cameras with IR MFZ lens (8MP) – 4K resolution along with power supply unit (POE based), with inbuilt/external surge protection unit and mounting accessories etc complete as per specifications and Tender Document.(TT Reporting at TTPA-2+TTEntry/Exit -2+Driver Entry/Exit-2+Helper Entry/Exit-2+Photo Pass issuance:- 2)

10

1102155

-

... More
Supply of FS Armoured Copper Power cable as per tender specifications.

-

-

-

... More
Installation,integration,testing and commissioning of TFMS Workstation with minimum 27" LED colour monitor, keyboard, mouse, KVM Switch, Licensed OS(latest supported by TFMS software), Licensed Antivirus, Licensed latest MS Office professional, TFMS licensed client software from same Radar Gauge OEM etc complete as per specification and tender document. Note:CPU of control room shall be kept in Panel room in 42 U Rack. KVM extender & reciever is to be supplied at no additional cost

-

-

-

... More
150 mm

2500

2339350

-

... More
Supply of IP based Desktop phone 2 Lines monochrome display, 3 audio keys (Mute/Speaker/Headset) with LED, 4 free programmable feature keys with LED, IEEE 802.3af PoE, Class 2, 10/100/1000 Base T.

42

748802

-

... More
Installation,commissioning & integration of video wall along with required controller & complete accecories , cables etc , mounting arrangement from wall/ceiling for fire fighting cum critical Alarm display & annuniciation cum CCTV application complete as per specifications and tender document. In control room:-Windows for all cameras should be available on single screen of 300-400 cm2 for min. 150 no. CCTV camera. Note: Two Number (min. 55” each or meeting size of video wall) for Alarm LED display and Fire fighting display along with one no. of hooter with provision of dual tone sound,ack push button & accessories.

6

54317

-

... More
Installation, integration, testing and commissioning of Biometric fingerprint cum contactless type smart card reader along with accessories, software , programming kit etc required as per standard design engineering, specification and tender document complete in all respect. (Turnstile:- Main gate security entry/exit -Dual Lane-Uni directional : 2x2 nos., Pedestrian Entry/Exit Platform to tank farm area (bi-directional)-4x2 nos., Pedestrian entry/exit platform near TLF entry/exit gate (bi-directional)- 2x2 nos., Flap barrier - 2x2nos., Portable reader for visitor pass issuance in Main gate security room- 2 Nos)

22

97635

-

... More
Installation, commissioning & integration of video wall along with controller & complete accecories , cables etc. for CCTV complete as per specifications and tender document. In location in charge room:-viewing window size should be preferably be between 250-300 cm2 ( in two pages) for CCTV camera.

2

18105

-

... More
24C x 2.5 sqmm

6000

4495800

-

... More
ETHANOL

3

27268

-

... More
100 mm

6000

4304640

-

... More
18 ways JB

45

851883

-

... More
4 ways JB

70

179489

-

... More
For Internal Floating Roof Vertical tanks (Primary and Secondary Radar Gauges - )

-

-

-

... More
Supply of Operator Interface Console Computer (OIC) minimum 24" colour LED monitor,keyboard, mouse, software, SCADA, GUI, OS, Antivirus, MS office professional etc. complete as per specifications and tender document.

-

-

-

... More
Supply of Structural steel (MS) for erection of cable bridge (if required) for laying of above ground cables at road crossing or any other place within the Terminal including painting, Civil foundations, nuts, bolts, washers, cleats, stiffners, gussets, base plate etc

10

1084396

-

... More
1P x 1.5 sqmm

2000

169920

-

... More
Installation, integration, testing and commissioning of LED monitor of minimum 55" along with required hardware and software for interfacing with TAS, lockable enclosure (wall mounted) for mounting the monitor along with accessories, canopy/ sunshade etc at invoice room for displaying the list of TTs whose invoice has been generated and TT is still inside license area complete in all respect as per tender requirement. Kindly note, no additional payment shall be made for any additional hardware/ software/ cable etc required for integration of the monitor with TAS.

1

13066

-

... More
RON Additive

2

12838

-

... More
Control Room equipments

-

-

-

... More
Sludge tank(1 no.)

1

297773

-

... More
3P x 1.5 sqmm

100

27376

-

... More
For U/G Product tanks (MS- 0 no., HSD - 0 nos., SKO - 0 no, Ethanol -3 nos., RON additive-2 Nos)

5

883076

-

... More
Supply of Hand held metal detector along with accessories complete as per specification and tender document.

4

18195

-

... More
Installation of pre-fabricated Metering Skid (MS structure) for mounting of complete metering equipments for metering of the quantity of product unloaded in TT unloading platform. This item also includes installation of (i) Full bore, zero leakage, fire safe ball valves (ii) Strainer cum Air eliminator with differential pressure transmitter across the Strainer along with accessories, SS tubing, needle valves etc complete, spool piece with tapping for installation of PT, RTD with TT- 2 No (iii) Microprocessor based Coriolis mass flow meter for white oil/water application along with display unit and mounting accessories with adjustable screw support etc- 2 No (iv) flameproof cum weather proof, min SIL 2 certified smart pressure transmitter with display unit & keypad, SS manifold, 1 no. SS isolation ball valve etc complete- 2 No (iv) flameproof cum weather proof, temperature transmitter along with display unit, RTD, Thermo well, mounting accessories etc complete- 2 No(v) online proving valves manifold comprising of 1 no. manual operated DBBV without actuator and 2 nos., full bore, zero leakage, fire safe ball valves along with associated piping, Tee connection, gaskets, copper jumpers, fasteners, blind flanges at one end of each ball valves, pipe fittings, WNRF flanges etc- 2 No (vi) Resistance - Capacitance type Tank Truck grounding unit along with display for resistance, capacitance values and accessories like 3 nos. of heavy duty flexible coiled cables with high quality rugged, heavy duty SS/ brass crocodile clamps, FLP double compression glands, Ex-Plug, mounting structure etc, complete - 1 No. (Common for the entire Skid) (vii) Ex-proof field mounted Remote Interaction Terminal (RIT) cum Driver Ack Push Button station along with FLP double compression glands and Ex-Proof-plugs, structural supports etc- 1 No. (Common for the entire Skid) (viii) Exd/FLP ESD push button stations, mushroom head type, with protection cover to avoid accidental activation along with mounting structure complete - 1 No. (Common for the enitre Skid), (ix) Microprocessor based Field mounted dual arm Batch Controller with interface to minimum 2 no. of main product in Flameproof and weather proof enclosure along with accessories like double compression glands, Exd Plugs, hoods, structural supports etc complete, (x) Intrinsically safe / flameproof type proximity card reader along with mounting accessories etc complete - 1 No. (Common for the entire Skid) (xi) Multistage Piston type Digital Control Valve (DCV) with secure locking arrangement of the needle valves to avoid manual throttling of the needle valves after final tuning of the DCV has been done, secure key etc along with accessories complete - 2 No (xii) Air eliminator (capacity shall be designed by the vendor) along with level switches and required accessories as per requirement . (xiii) Pump for unloading the TT suitable for Bio-diesel / Ethanol / NMA etc.(xiv) portable type Density probe for density measurement along with its integration with batch controller / DCS complete with accessories

2

258134

-

... More
- Valve Automation System (ROSOVs, MOVs, DBBV, MCS Interface, SOVs, etc) -Tank Farm Management System ( TFMS Server, Primary & Secondary Radar Gauging, AOPS, Level transmitters, Level Switch, Density probes, MSTW, CIU etc) - MCC, Pump, Borewell, DG Sets, Air compressors - PA paging Interface - HC Detection System Interface -FAS Interface, Fire Fighting System, HVLR, Fire Alarm System Interface, Fire Engines, DG Set, Jockey pumps, Foam pumps, CFFS, Sprinkler & Fixed foam pourer system etc - VRU Package Units -Effluent Treatment plant - CCTV systems - Access Control System - SKO Blue Dye Dosing System - ESD System, Emergency panel, Power ESD, Local ESD, Wailing sirens - Pressure Transmitters - UPS & Power distribution boards etc - Interface with IOCL SAP through firewall - Any other Third Party Interface/ devices as per scope of the work order etc Note: The offered software shall also includes fault detection module and Web Server software for remote viewing over IOCL Intranet across India as detatiled in the tender document.

-

-

-

... More
3.5C x 120 sqmm

800

106672

-

... More
Supply of Ex-proof and weather proof Hooter cum Beacons along with accessories, mounting structure etc complete as per specification and tender document for audio visual alarm at field in case the MOVs installed at tank dyke drain and tank water draw off line is not fully closed. (Tentative location : Each product tank (MS)-3 No., (HSD) - 2 No. (SKO) -2 No., Pump House (TLF and TW) - 2 No.,ETP-1 No.,VRU-1 No.) Location : Near each tank dyke and to be installed outside dyke.

11

279667

-

... More
With minimum 8 elements temperature sensor (for above ground tanks )

-

-

-

... More
License area Exit barrier gates ( Near invoice room - 2 no. X 1)

2

109128

-

... More
Supply of online proving valves manifold comprising of 1no. manual operated DBBV without actuator and 2 nos. of 50 NB, full bore, zero leakage, fire safe ball valves along with associated piping, Tee connection, gaskets, copper jumpers, fasteners, blind flanges at one end of each ball valves, pipe fittings, WNRF flanges etc for each loading point assembly for making arrangement to connect Mobile master meter for proving of TLF MFM complete as per specifications and tender documents.

4

712096

-

... More
Installation, Configuration, Integration, Testing and Commissioning of flameproof cum weather proof to IP 65 or better SIL 2 Smart Differential pressure transmitter with in built display, SS 3 way manifold, SS canopy/sunshade, other erection material etc as per hook up drawing attached else where in tender complete as per specifications and Tender Document. (Transmitter will have IEC/ATEX certified minimum and any other certification as stated else where in tender)

-

-

-

... More
Installation, integration, testing and commissioning of thermal printer for printing of FAN as per specifications and tender document

2

5866

-

... More
Installation, integration, testing and commissioning of public address system along with accessories like speakers, amplifier, mike complete for announcement in TT Parking area as per specifications and tender document.

1

13122

-

... More
Supply of layer 3 managed gigabit Ethernet switch with minimum 24 ports or as per site requirement whichever is higher along with SFP, copper, fibre modules, accessories complete as per specifications and tender documents for Plant Communication & EPBAX system.

2

636041

-

2

16175

-

... More
Ethanol Dosing System

-

-

-

... More
RON Additive

2

709047

-

... More
Installation, commissioning & integration of video wall along with controller & complete accecories , cables etc. for CCTV complete as per specifications and tender document. In security cabin:-viewing window size should be preferably be between min. 150-200 cm2 ( in two pages) for CCTV camera.

2

18105

-

... More
At the inlet of Fire Engine Service tanks

2

4878

-

... More
Installation, configuration, integration, testing and commissioning of HD IP Fixed Dome camera with IR and MFZ lens (2MP) along with power supply unit (POE based), with inbuilt/external surge protection unit and mounting accessories etc complete as per specifications and Tender Document.

11

52335

-

... More
Supply, configuration and testing of Scratch proof, waterproof Smart cards along with messages printed compatible with proximity card reader complete as per specifications and tender document.

1000

566400

-

... More
Installation of pre-fabricated Metering Skid (MS structure) for mounting of complete metering equipments as per BOQ. The metering assembly comprises of : Main product line: Strainer cum Air eliminator, Spool piece with tapping for additive dosing, MFM, Spool piece with tapping for Temperature Transmitter & pressure Transmitter installation with tapping for connecting outlet of TRV, DCV, Online Master Meter proving manifold, Spool Piece with tapping for Ethanol blending, ON-Off valve & TRV installation. Blend Product line: Strainer cum air eliminator, MFM, Spool piece with tapping for Temperature Transmitter & Pressure Transmitter installation, DCV, Online Master Meter proving manifold, NRV, isolation valve and finally connected to Main stream line tap off point after DCV. Additive Dosing System comprises of isolation valve, Additive injection panel/ block, connecting piping, NRV, isolation valve and finally connecting to Main stream tap off point before MFM. Provision to be made in the skid for mounting of Batch Controller, Rack Monitor, Grounding unit, RIT cum Driver's Ack Push button stations (if applicable), card reader, FLP sockets, FLP junctions boxes (Power, Signal and Control), FLP power isolator switch, interconnecting cables from respective equipment to JBs, cable trays with collar height of 50mm with covers, glands, support, MS structure, nuts, bolts, gaskets, Tees, bends, elbows, WNRF flanges, nozzles, plugs, isolators, any other equipment if required as per design Engineering etc complete as per specification and tender document. Note: Stud Bolts, Blind Flanges (if applicable)

24

894600

-

... More
At the inlet of DG set Service tanks

3

94178

-

... More
36C x 1.5 sqmm

1500

95580

-

... More
Supply of HD IP PTZ Camera (2MP) along with power supply unit (POE based) with POE injector (industrial grade),with inbuilt/external surge protection unit and mounting accessories etc complete as per specifications and Tender Document.

49

5106315

-

... More
Fabrication, cutting, laying and connecting of GI strip ( 50mm X 6mm) with Hot dip galvanizing (800 gm/m2 as per IS 4759) along with accessories required for complete Terminal Automation System as per Standard Design Engineering, specification and tender document.

10000

2277400

-

... More
Supply of FRLS Armoured Copper Power cable as per tender specifications.

-

-

-

... More
At Main Gate Security Room- copper ports of 10/100/1000 MBPS [Control LAN - 2 nos.,CCTV - 2 no.] (Minimum 8 nos. copper ports and 2 nos. optical ports)

4

408992

-

... More
10P x 1.5 sqmm

2100

96642

-

... More
20C x 1.5 sqmm

3800

188328

-

... More
4C x 1.5 sqmm

1200

162840

-

... More
Supply of weatherproof Hooter along with accessories, fault isolation module (inbuilt/ External), structural supports etc required as per standard design engineering, specification and tender document complete in all respect.

-

-

-

... More
Supply and configuration of Proximity smart access cards as per the specification and tender document.

500

208860

-

... More
Installation, Integration, Configuration, Testing and Commissioning of Microprocessor based Field mounted dual arm Batch Controller with interface to minimim 2 nos.of main product + 2 nos. of blend product + 4 nos. of additive product in Flameproof and weather proof enclosure alongwith accessories like double compression glands, Exd Plugs, hoods, structural supports etc complete as per specification and tender document.

-

-

-

... More
Design, fabrication and supply of Heavy Duty self supported Hot Dip Galvanized Poles for mounting of CCTV cameras along with civil foundation along with GI foundation bolt, mounting brackets, ladder arrangement (taking into account of safety during climbing) on the pole for installation and maintenance of cameras, SS nut & bolts for fixing camera and other accessories required for complete installation and commissioning of the pole, submission of structural stability certificate based on existing soil bearing capacity and wind speed from Govt. Engineering colleges etc complete as per specifications and Tender Document of below mentioned height of the pole. (Foundation drawing and other details to be submitted prior to installation as per tender document) Note: In case pole do not have ladder arrangment for maintenance purpose, then vendor to arrange for ladder for installation & maintenance purpose throughout the contract period including CAMC period at no additional cost to IOCL.

-

-

-

... More
TLF pumps and TW Pump Discharge end (3 MS, 3 HSD, 2 SKO in TLF and 3 MS, 3 HSD, 2 SKO,2 Ethanol in TW)

18

54501

-

... More
Installation, Integration, Testing and Commissioning of multi point temperature averaging sensor with integrated water interface probe (MSTW) along with mounting accessories etc complete as per specification and tender document.

-

-

-

... More
For MOVs in water draw off line (AG tanks- 7 Nos)

7

18361

-

... More
TLF bays (1 no. Per bay)

6

327386

-

... More
For product line size 100 mm - TLF

12

79083

-

... More
Note: Piping from Additive tank skid upto TLF header line up to meter skid along with isolation valve & return line shall be supplied and installed by IOCL. Integration of additive pumps for remote operation, level measurement shall be in the successful bidder's scope.

-

-

-

... More
License area Exit gate

2

527554

-

... More
For Water Tanks (2 nos.), Sludge tank (1 no.)

3

159586

-

... More
Fire Engine Suction and Discharge end

4

12111

-

... More
Supply of FRLS Armoured Copper Control cable as per tender specifications.

-

-

-

... More
4C x 2.5 sqmm

5500

259600

-

... More
For TLF product loading

6

34493

-

... More
4/6 M pole with Accessories as per specification of Tender

35

467763

-

... More
PLANT COMMUNICATION SYSTEM

-

-

-

... More
19" Rack mounted at Control Room, form factor - Rack , Max. 2U height ( 3 OICs, 1 for fire fighting System)

4

1224476

-

... More
Decantation pump suction and discharge end ( 1 MS, 1 HSD, 1 SKO)

6

287660

-

... More
Supply of Integral Explosion Proof HD IP Fixed Cameras and MFZ lens (2MP) along with power supply unit , with inbuilt/external surge protection unit and mounting accessories etc complete as per specifications and Tender Document.

6

1774028

-

... More
Combination/Multi sensor Detector

285

386072

-

... More
Installation, integration, configuration, testing and commissioning of Outdoor Field Call Station : • Connection to Fast‐Ethernet network, power supply via PoE function • SIP‐connections support • Priority levels setting • Easy maintenance and remote administration • LED indications for incoming, missed call and line status (busy) • Noise reduction/elimination adjustable microphone • 25W amplifier for additional loudspeaker • Identification label • Hot swapping • Protection degree Min. IP65 Installation, integration, configuration, testing and commissioning of Exproof cum Weatherproof (IP65) industrial wall-mounted IP based for two-way communications, with Dial keypad, Handset ,status indication, identification label,25 W amplifier for additional loudspeaker with mounting accessories, Sunshade, Double compression Exd gland & Exd blind plugs complete as per specification and tender documents.

16

446530

-

... More
Point type Infrared detector (Indicative location: Each tank dyke sump pit inside dyke wall MS- 4 nos.,Near ROSOVs of MS - 12 nos., MS & Ethanol pump seal - 9 nos., Sludge Pump Seal - 2 nos., Pump house drain pit (TLF and TW) - 2 no.; Vapour recovery system drain pit - 1 no., OWS/ETP Pit - 1 No.)

31

7086021

-

... More
Supply of Outdoor Field Call Station : • Connection to Fast‐Ethernet network, power supply via PoE function • SIP‐connections support • Priority levels setting • Easy maintenance and remote administration • LED indications for incoming, missed call and line status (busy) • Noise reduction/elimination adjustable microphone • 25W amplifier for additional loudspeaker • Identification label • Hot swapping • Protection degree Min. IP65 Supply of Exproof cum Weatherproof (IP65) industrial wall-mounted IP based for two-way communications, with Dial keypad, Handset ,status indication, identification label,25 W amplifier for additional loudspeaker with mounting accessories, Sunshade, Double compression Exd gland & Exd blind plugs complete as per specification and tender documents.

16

3507904

-

... More
Supply of redundant fault tolerant Integrated Distributed Control System (DCS) along with DCS Panels, Marshalling Panels, Biometric fingerprint cum contactless smart card reader with accessories, limit switches, Input Output modules, Power supply units, Relays with base, barriers, TBs, Redundant host communication ports, Serial Interface Modules, HART modules, other communication modules, HMI , wirings, glands, plugs, other modules/ hardware required for interfacing with all the required field and control room equipments including spare requirements, licenses, tags, GUI, licensed OPC compliant software etc complete as per specification and tender document. Note: Any other hardware, software, OPC server, Historian Server, storage, firewall, functional control key board etc required as per tender specification and design requirements, the same to be provided by the vendor at no additional cost to IOCL.

1

15483365

-

... More
4P x 1.5 sqmm

100

36934

-

... More
Installation, integration, testing and commissioning of heavy duty high speed laser printer and accessories for invoice printing in lock shed room, complete as per specifications and tender document.

2

5866

-

3

1679287

-

150

64251

-

... More
Supply of Multistage Piston type Digital Control Valve (DCV), NRV, isolation valve for line size 50 mm alongwith accessories, with secure locking arrangement of the needle valves to avoid manual throttling of the needle valves after final tuning of the DCV has been done, secure key etc along with accessories complete as per specifications and tender document.

4

1289433

-

... More
Second Year @1.5% of the basic CAPEX cost

1

7067414

-

... More
SKO (for line size of 100 mm )

2

2295387

-

... More
Supply of PVC cards for printing of photo pass as per specification and tender document.

1000

397660

-

... More
Installation, integration, configuration, testing and commissioning of IP based Desktop phone Min 4” Color TFT Display, soft keys with LED, 3 audio keys (Mute/Speaker/Headset) with LED, Bluetooth 2.1 BR/EDR, IEEE 802.3af PoE, Class 2, 10/100/1000 Base T.

1

5328

-

... More
Installation of 42U Rack enclosure cabinet/System cabinet with 19" rack size, along with accessories like limit switches, earthing arrangements, breaker, SPD type 1+2,fuses, LIU, terminal blocks and wiring etc complete as per specification and tender document for mounting of below mentioned equipments. For mounting PA Paging Servers along with associated rack type monitors & keyboard, mouse, 4 port industrial grade KVM switches, power adapters, networking & OFC components, Ethernet switch, GSM modems, MCBs etc. as per specification and tender documents.

1

15341

-

... More
For Internal Floating Roof Vertical tanks (Primary and Secondary Radar Gauges - )

-

-

-

... More
Supply of flameproof cum weather proof to IP 65 or better SIL 2 smart pressure transmitter with in built display, SS manifold, SS isolation valve, SS canopy/sunshade, other erection material etc as per hook up drawing attached else where in tender complete as per specifications and Tender Document. (Transmitter will have IEC/ATEX certified minimum and any other certification as stated else where in tender)

-

-

-

... More
For Cone Roof Vertical tanks (Primary and Secondary Radar Gauges)

-

-

-

... More
SIL verification from approved third party agencies. (For SIFs as per SIL Assessment study report/detail engg). All required documentation as per specs and other documentation mentioned elsewhere in tender scope has to be submitted. Complete as per specification / tender documents.

1

491040

-

... More
Tower type with Monitor :- Mkt. TM room - 1 No.

1

267635

-

... More
Supply of minimum 10 ports ( 8 nos. copper ports and 2 nos. optical ports) Layer 2 Managed Ethernet Switches along with accessories for connecting BCU with TAS, all the hardware/IP telephones/PA system equipments installed in Invoice room, Security room, Terminal Manager room and other TAS equipments as per system architecture and design requirement complete as per specification and tender document. Note: 1. Ethernet switches for BCU communication shall have suitable mounting arrangement to mount inside FLP JBs. 2. The switches are to be configured in Dual Redundant mode. 3. All OICs, Workstations, Servers other than that of CCTV, ACS & TFMS are to be connected to both plant management and control LAN so that all the GUIs can be seen in all the PCs irrespective of its nomenclature like TTES, OIC, EWS, TM PC etc. 4. Printers to be connected to Plant Management LAN and to be configured to all PCs, Workstation, TTES etc so that printout command can be issued from any of the Machine.

-

-

-

... More
Supply of Web Server (Rack type mountable in 19" rack ) , Rack type CPU - 2U Max. , LED monitor of minimum size of 27" suitable for 24x7 operation, keyboard, mouse, KVM Switch, web application software, SCADA, GUI, OS, Antivirus etc located in panel Room complete as per specifications and Tender Document. Note: CPU of control room shall be kept in Panel room in 42 U Rack. KVM extender & reciever is to be supplied at no additional cost

1

631774

-

... More
Raw water sump

1

51881

-

... More
1P x 1.5 sqmm

11000

1272040

-

... More
Laying, glanding, ferruling, termination of FRLS Un-armoured Copper Signal cable as per tender specifications.

-

-

-

... More
Plant ESD Push Button Station ( Each battery of TLF - 1X1 No, TLF Pump house- 1 no, TW Pump House - 1 no., TT unloading Area - 1 No, One no per tank dyke (1*3)- 3 No, Gate from Plant to Wagon Area - 1 no. )

8

103943

-

... More
Third Year @2.5% of the basic CAPEX cost

1

11779023

-

... More
4 ways JB

70

620739

-

... More
Comprehensive Annual Maintenance Contract for a period of Seven years for entire Terminal Automation System after successful completion of SAT as described Technical Bid. Cost of all the required spares, hardwares, software modification, tools and tackles, ladders, labours, Preventive & Breakdown maintenance Service, calibration of instruments, proving & stampings of metering equipments, rectification/ replacement of faulty TAS equipment etc required for running and maintenance of the entire Terminal Automation System to the desired performance level throughout the contract period of CAMC is included in the item rates and the same has to be borne by the Vendor. The scope also includes posting of Resident Engineer (s) during warranty period to take care of running and maintenance of the entire Automation System complete as per the tender document.

-

-

-

... More
Supply of RFID tags for issuance to vehicles to be identified by RFID reader as per specification and tender document.

500

132750

-

... More
Supply of industrial grade redundant Serial to Ethernet converter of 8 port with mounting acessories etc complete in all respect as per specification and tender document. (Ports:- 6 Main + 2 Spare)

-

-

-

... More
24 ways JB

30

655431

-

... More
Supply of UPS Power Distribution Panel along with Biometric fingerprint cum contactless smart card reader for front and rear gate sepearately with accessories for powering DCS Panel, Safety PLC Panel, TAS-MS, OIC, EWS, TFMS System, TTES, printers, Bay Instruments other control room equipments, Tank Farm Instruments, CCTV system, Fire Detection System, Access control system, Bay Queue Display boards, other display boards, ROSOV ESD port, header line instruments and any other TAS equipments where UPS power are required for smooth un-interrupted operation. Miscellaneous Instrumentation comprising of suitable MCCBs for Isolation, MCB etc are to be provided. The panel shall be complete in all respects with necessary indication lamps for powering, necessary control wiring with digital voltmeter & digital ammeter separately for UPS and Auxilliary supply for front and rear seperately etc as per specifications and tender document. Note: Minimum 20% spare power points to be made available for future use.

1

550717

-

... More
For Primary Radar gauges installed on A/G product tanks, under ground product tank, water tank & Sludge tank

1

4624

-

... More
10C x 1.5 sqmm

7400

340548

-

... More
Supply of weather proof and Explosion proof Hooter cum beacons/ flash light along with accessories and structural supports as per specification. ( Tentative location : Each MS product tank dyke-(3 )nos., Near Pump House (TLF and TW) -2 no. & Vapour recovery system-1no., OWS/ETP - 1 no.)

7

177969

-

... More
Push Buttons Outside Dyke Walls

-

-

-

2

1119525

-

... More
Installation, integration, configuration, testing and commissioning of IP based Desktop phone 2 Lines monochrome display, 3 audio keys (Mute/Speaker/Headset) with LED, 4 free programmable feature keys with LED, IEEE 802.3af PoE, Class 2, 10/100/1000 Base T.

42

122710

-

... More
License area Entry gate

2

527554

-

... More
8 M pole with cantilever arrangement for mounting of 1 fixed camera at 6m and LED flood light at 8m of the pole across perimeter as per tender

35

2425962

-

... More
Supply of Wall mounted Network Rack-minimum 12U ,19" Network Rack of suitable sizes for mounting of Ethernet switches along with accessories like power sockets, MCBs, fan, LIU, Patch Panel, OFC components ,mounting accessories etc complete in all respective at various Buildings of IP PABX network. (Admin Building - 2 Nos, Invoice Room- 1 No, Security Room near Invoice Room - 1no, Main gate Security Room- 1 no)

5

316228

-

... More
For Cone Roof Vertical tanks (Primary and Secondary Radar Gauges)

-

-

-

... More
Open path type Infrared detector (0-90m) along with alignment telescope, configuration & testing kit etc (Tentative location: .) MS tanks covering ROSOVs and outside dyke also - 8 nos

8

61756

-

... More
1T x 1.5 sqmm

300

10620

-

... More
Local Area Network (LAN) works

-

-

-

... More
Laying, glanding, ferruling, termination of FS Armoured Copper Control cable as per tender specifications.

-

-

-

... More
Supply of parallel redundant Communication Interface Units (CIU) including all accessories etc for tank farm management system complete as per specification and tender document.

-

-

-

... More
Installation, integration, configuration, testing and commissioning of 25W Explosion & weather proof Horn type Speaker and mounting accessories etc complete as per specifications and Tender Document. Type : Pole Mountable, suitable for speech and music reproduction Rated power : 25 W Frequency range : 20 Hz TO 20 KHz Ingress protection : Min. IP 65, FLP Enclosure Required Standard : EN 60065

16

137729

-

... More
Installation,errection & foundation of Heavy Duty self supported Hot Dip Galvanized Poles for mounting of CCTV cameras along with civil foundation along with GI foundation bolt, mounting brackets, ladder arrangement (taking into account of safety during climbing) on the pole for installation and maintenance of cameras, SS nut & bolts for fixing camera and other accessories required for complete installation and commissioning of the pole, submission of structural stability certificate based on existing soil bearing capacity and wind speed from Govt. Engineering colleges etc complete as per specifications and Tender Document of below mentioned height of the pole. (Foundation drawing and other details to be submitted prior to installation as per tender document) Note: In case pole do not have ladder arrangment for maintenance purpose, then vendor to arrange for ladder for installation & maintenance purpose throughout the contract period including CAMC period at no additional cost to IOCL.

-

-

-

... More
For mounting of Rack mounted CPUs of Control room console workstation (Rack type) , one number 19" rack mounted monitor, rack mounted keyboard, mouse, KVM switches for connection of all CPUs along with power adaptors, MCBs, required accessories etc as per specification and tender document.

2

344290

-

... More
Note: 1. All the equipments, JBs, cable trays, interconnecting cables etc as stated above to be installed and loop tested at factory. Complete assembly to be dispatched at site. The skid to be designed and fabricated by the party taking into consideration of all the equipment sizing, space available for mounting of the skid at the bottom of the gantry etc. The design Engineering along with weight calculation of individual skid excluding equipments to be submitted to IOCL prior to taking up fabrication job for review purpose. Payment shall be made based on theoretical weight calculation of the skid excluding weight of equipments, JBs, cable trays. The rate is also inclusive of surface preparation, powder coating, painting, transportation of the skid to site etc complete in all respect. 2. All unuse nozzle/ tapping/ opening to be blind flanged. 3. For SKO metering SKID, tapping to be provided in the skid for both bottom and top loading as per design Engineering if applicable.

-

-

-

... More
1P x 1.5 sqmm

44000

1557600

-

... More
Supply of face detection cum fingerprint cum contactless type smart card reader with controller along with electromagnetic door lock of 600 lb for single door/double door, 2 nos. of door position magnetic contact with buzzer etc as per specifications and tender document. (Location : control room first floor main entry/exit door - 2 nos., control room first floor secondary entry/exit door - 2 nos., console room to panel room entry/exit 2nos, Panel Room exit door - 1no., PMCC first floor- 1 no, Sample room- 1nos, Invoice room-1 no ) Note : 7 nos. electromagnetic door lock to be provided with this item at no additional cost to IOCL.

7

1209643

-

... More
Installation, Testing and Commissioning of online proving valves manifold comprising of 1no. manual operated DBBV without actuator and 2 nos. of 50 NB, full bore, zero leakage, fire safe ball valves along with associated piping, Tee connection, gaskets, copper jumpers, fasteners, blind flanges at one end of each ball valves, pipe fittings, WNRF flanges etc for each loading point assembly for making arrangement to connect Mobile master meter for proving of TLF MFM complete as per specifications and tender documents.

4

28164

-

... More
Laying, ferruling, termination of Pre fab CAT 6 Ethernet un-armoured cable as per tender specifications and instructions of Engineer in charge.

-

-

-

... More
20C x 1.5 sqmm

3800

1685984

-

... More
Across Strainers in Fire Engine Pump house (Fire Pump - 2 Nos+ Jockey Pump - 2 Nos)

4

17704

-

... More
Installation, integration, testing and commissioning of flameproof cum weather proof temperature transmitter along with display unit, RTD, Thermowell, mounting accessories etc complete as per specifications and tender document. (Mounting at each TLF loading point on main product for line size 100 mm)

12

40469

-

... More
Supply of SKO Blue Dye Dosing Skid comprising of 1 no. SS Blue dye tank of Min. capacity of 500 Ltrs, Blue Dye dosing pumps of minimum capacity of 200 LPH along with Flameproof Motor (2 Nos.) , 1 no. agitator with FLP motor, Mild Steel Skid, NRVs, Flanged SS ball valves, Pressure Relief Valve, pulse dampener, Pressure transmitter with inbuilt display unit and keypad, solenoid valves (4 nos.), Turbine flow meters (2 nos. - for calculating the volume of SKO receipt into blue dye tank and volume of diluted Blue dye dosed into SKO receipt header line), Rotameter, Strainer with DPT, piping, flanges, auxiliary potential free contacts/serial communication for remote operation and feedback of the pumps, starter etc. complete as per specifications, drawing and tender document. Note: Blue dye to be injected in SKO receipt header line during product receipt. Provision to be made for diluting the blue dye with SKO tapped from the main receipt line before dosing as per drawing , Auto flushing of blue dye dosing system complete as per specification and tender document.

1

1244367

-

... More
12P x 1.5 sqmm

2800

138768

-

... More
Across Strainers in Fire Engine Pump house (Fire Pump - 2 Nos+ Jockey Pump - 2 Nos)

4

242773

-

... More
Supply of weather proof LED bay queuing display board (Minimum 15 lines x 100 mm Character height x 25 characters per line) for outdoor installation at TT parking area along with structural steel for mounting of the same, canopy/sunshade etc as per specifications and tender document.

1

674353

-

... More
8 ways JB

50

609057

-

... More
For Cone Roof Vertical tanks (Primary and Secondary Radar Gauges )

-

-

-

... More
Installation, Testing and Commissioning of top loading arm of size 100 mm NB along with 1 no. full bore isolation ball valve (100 mm), associated piping for connecting loading arm with the metering skid & TRV outlet to nozzle before ON-OFF valve, mounting structure etc complete as per specifications and tender document. Application: SKO

2

20041

-

... More
12C x 1.5 sqmm

9800

450996

-

... More
TLF pump and TW Pump Suction end (3 MS, 3 HSD, 2 SKO in TLF and 3 MS, 3 HSD, 2 SKO,2 Ethanol in TW)

18

54501

-

... More
Installation, integration, configuration, testing and commissioning of Digital Rodent Repellent System along with mounting accessories for main controller(s) & transducers etc complete as per specification and tender document (Minimum nos of transducers: Security room near Invoice Room - B - 4 nos)

1

12883

-

... More
Supply of Level switch ( Magnetic Float / displacer type ) for low and high level alarm along with mounting accessories etc as per specifications

-

-

-

... More
Design, Engineering, Set-up, Installation, Configuration, testing & Commissioning of redundandant TAS Management Server (Rack type mountable in 19" rack ) along with 1 no. rack type (1U) LED monitor of minimum size of 19" suitable for 24x7 operation along with High availability redunancy software working on redundant (Primary and Secondary) hot standby mode, keyboard drawer, optical mouse and combo 4 port KVM switch, OS, Antivirus, SQL, oracle, RDBMS (license copy) etc complete as per specifications and Tender Document. OR Design, Engineering, Set-up, Installation, Configuration testing & Commissioning of Dual Mode Redundant Grade with built in redundancy TAS Management Server (Rack type mountable in 19" rack ) along with 1 no. rack type (1U) LED monitor of minimum size of 19" suitable for 24x7 operation, keyboard with drawer, optical mouse and combo 4 port KVM switch, OS, Antivirus, SQL, oracle, RDBMS (license copy) etc complete as per specifications and Tender document. TAS Management Servers (TAS-MS) shall have either of the above mentioned configuration meeting the complete specification and tender requirements. In addition, the TAS-MS shall be configured to have Zero Downtime to repair, Full data redundancy shall be provided using proven technology, it shall also provide port level redundancy. The system solution shall be capable of self fault detection and isolation, all necessary hardware/software configuration etc to achieve the same shall be included.

1

6061

-

... More
18 ways JB

45

182929

-

... More
For Xtragreen

1

1014279

-

... More
TLF bays (1 no. Per bay)

6

26344

-

... More
Installation, configuration, integration, testing and commissioning of rack mounted CCTV Server (s) along with rack type monitor, optical mouse and combo 4 port KVM switch, OS, Antivirus, LIU etc complete as per specifications and Tender Document. Note: In case multiple servers are required to meet the tender requirement, vendor to provide the same at no additional cost to IOCL. In additional to above, Vendor to provide failover server to have redundancy in CCTV server such that failure of one server should not affect the CCTV operation and recording at its full resolution at no additional cost to IOCL.

1

7110

-

... More
8C x 1.5 sqmm

1100

46728

-

... More
Supply of Additive tanks (500 Litres each) and pump module for XTRAPREMIUM /XTRAGREEN comprising of Additive Tank, Additive Pumps (Two per tank) , Mild Steel SKID, flameproof cum weather proof, min SIL 2 certified smart pressure transmitter with display unit & keypad, SS manifold, 1 no. SS isolation ball valve,flameproof cum weather proof to IP 65 or better SIL 2 Smart Differential pressure transmitter with in built display, SS 3 way manifold, Flameproof Motor, NRV 25 mm, Flanged ball valve 25 mm, Pressure Relief Valve, Pressure Gauge with pulse dampener, Strainer 25 mm, interconnecting pipings (25 mm SS), flanges etc. auxiliary potential free contact/serial communication complete as per specification and tender document.

-

-

-

... More
Supply of Colour photo pass printer along with integrated/seperate scanner for photo pass printing as per specification and tender document.

2

359258

-

... More
Supply of additive injection mono block along with accessories for XTRAPREMIUM and XTRAGREEN complete as per specification and tender document. Note - All the wetted parts within Additive injection panel/ block shall be of SS 316 or better.

4

914179

-

... More
MS - 1.6 KL

1

7739

-

... More
Customized Printer Tables of Godrej or equivalent make (2 no. at Main Gate security room for mounting 2 nos. of Photopass printer and 1 visitor pass printer, 2 no. at Invoice room for mouting 2 nos of printer for invoice printing, 2 nos. in control room for two printers, 2nos at security room near Invoice Room for mounting 2 nos of FAN printer ))

8

20107

-

... More
For TLF product loading

6

4120545

-

... More
Supply of Wall mounted/wheel mounted Network Rack-minimum 19U 19" Rack for mounting of Ethernet switches/LIU/ OFC components along with accessories like power sockets, MCBs, fan, mounting accessories etc complete in all respective at (iii) Admin Building - 2nos. for TAS equipments. Supply of required OFC components & accessories like LIU, splice trays, loaded adaptor, blank plates, UTP cables, Fibre patch cords, pigtails, tags, ties, Ethernet cable with RJ45 connector etc complete in all respect for functioning of CCTV camera.

2

188597

-

... More
Weather proof Hooter

25

56669

-

... More
Installation, Integration, Configuration, Testing and Commissioning of Terminal servers (rack mounted) with inbuilt/externally mounted lightening and Surge Protection Device Type (1+2) at all Serial ports, for interfacing and integration of card readers, Bay Queue display units (Indoor & outdoor), LED Display unit for TT reporting & Bay allocation with TAS in case the above listed equipments do not come with open communication protocol compatible to be directly interfaced with DCS Serial / MODBUS TCP IP module complete as per specification and tender document. Note: Terminal Servers to be configured in Dual Redundant mode.

-

-

-

... More
Supply of intrinsically safe / flameproof type proximity card reader along with mounting accessories etc complete as per specifications and tender document for authorisation of TT at

-

-

-

... More
Other Services

-

-

-

... More
12C x 1.5 sqmm

9800

2705976

-

... More
Supply of Necessary hardware Like SS Tubing, reducer, Elbows, equal Tee ,unequal tee, Flanges, Coupling, Ball Valve for Isolation, NRV, 15 mm back pressure regulator on return line etc as required for piping and commissioning of the system complete in all respect.

1

643354

-

40

19871

-

... More
For U/G Product tanks

5

19918

-

... More
3C x 1.5 sqmm

100

3540

-

... More
Laying, glanding, ferruling, termination of FRLS Armoured Aluminium Power cable as per tender specifications.

-

-

-

... More
BLUE DYE DOSING SYSTEM

-

-

-

... More
1P x 1.5 sqmm

44000

4153600

-

... More
Supply of ASTM A106 Gr B Schedule 80 pipe of 25 NB from additive header pipe to additive injection panel at TLF bay and from last additive point to additive skid for both XP and XM dosing complete as per tender document.

100

117292

-

... More
Installation, Integration, Testing and Commissioning of Exd/FLP ESD push button stations, mushroom head type, with protection cover to avoid accidental activation along with mounting structure complete as per specification and tender document. ( For 16 bays)

8

20031

-

... More
Supply of minimum 24 ports Layer 2 Managed Ethernet Switches (10/100/1000 MBPS) along with SFP, copper, fibre modules, accessories for providing IOCL LAN as per specification and tender document. (i) Admin building - 2 Nos, (ii) Main Gate Security room - 1 No, (iii) Security room near Invoice Room- 1 No, (iv) control room - 1 No, (v) Invoice room - 1 No, Note: 1. OFC ports to be provided for connecting interbuilding LANs and the communication is through OFC cable

-

-

-

... More
Foam Daughter Tanks for HVLR

4

17242

-

... More
8 ports - Invoice room (1 No), Control room (1 No), Main Gate Security room(1 No), Security Room near Invoice Room(1 No)

4

563374

-

... More
For A/G Tanks with 3 elements

-

-

-

... More
Security barrier gates (TTPA Entry/Exit gate- 2 no and Entry/Exit Gate of Security Block near Invoice Room - 2no. )

4

17563

-

... More
Supply of solenoid valves (SOV) of 25/32/50/65 NB (as per line size) along with 3 no. of isolation by pass valve with complete pre-fabricated assembly to bypass the SOV with associated piping, mounting accessories etc complete as per specification and tender document. Note: SOV along with bypass arragement need to be supplied factory fitted along with baypass valve with flange end connection.For Ethanol tank HVLRs SOV is not required.

-

-

-

... More
MS, HSD Tanks Sprinkler & Foam Line

20

958868

-

... More
Laying, clamping, ferruling, termination of CAT 6 Ethernet armoured cable as per tender specifications and instructions of Engineer in charge.

10000

401200

-

... More
Installation, integration, configuration, testing and commissioning of Rj I/O with Voice Tag, Face Plate & Back Box (near each phone)

42

28298

-

... More
For MFM and other serial devices integration to DCS -TLF

4

38147

-

... More
Tower Type in Photopass room/Invoice room for TT crew/Contractor etc.

1

2972

-

... More
Supply of minimum SIL 2 certified Non - contact type Radar level gauges with instrument accuracy of +/- 1 mm or better along with mounting accessories etc complete as per specification and tender document. (Transmitter will have IEC/ATEX certified minimum along with any other certification as stated else where in tender)

-

-

-

... More
4C x 4 sqmm

4000

1137520

-

... More
Supply of Auto Tank Gauging (ATG) probe combo with density measurement (Wireless or Wired) including necessary accessories as per Tender specifications.

-

-

-

... More
2P x 1.5 sqmm

10330

377871

-

... More
Installation, integration, configuration, testing and commissioning of Layer 2 Managed Ethernet Switches (10/100/1000 MBPS) along with SFP, copper, fibre modules, accessories for IP PABX network (Non Redundant) complete as per specification and tender document

-

-

-

... More
Laying, glanding, ferruling, termination of FRLS Armoured Copper Power cable as per tender specifications.

-

-

-

... More
48C x 1.5 sqmm

8000

7693600

-

... More
For connecting all MODBUS TCP IP devices ( any other devices) to DCS Ethernet port directly for integration (copper ports of 10/100/1000 MBPS)- to be located in Control Room ( Minimum 8 nos. copper ports and 2 nos. optical ports)

2

6251

-

... More
Supply of Microprocessor based Field mounted dual arm Batch Controller with interface to minimum 2 nos. of main product + 2 nos. of blend product + 4 nos. of additive product in Flameproof and weather proof enclosure along with accessories like double compression glands, Exd Plugs, hoods, structural supports etc complete as per specification and tender document.

-

-

-

2

1119525

-

... More
Across TLF and TW pump Strainers

18

1092479

-

... More
For mounting of Rack mounted Master Control Stations for MOVs & DBBVs along with power adaptors, MCBs, required accessories etc as per specification and tender document.

2

12533

-

... More
12P x 1.5 sqmm

2800

2183944

-

... More
Supply of thermal printer for printing of FAN as per specifications and tender document

2

44875

-

... More
Supply of flameproof cum weather proof to IP 65 or better bi-colour magnetic flap type level gauge (side mounted) along with level transmitter with installed accuracy +/- 6 mm or better along with mounting accessories, complete as per specification and tender document.

-

-

-

... More
Note: Piping from Additive tank skid upto TLF header line along with isolation valve & return line shall be supplied and installed by IOCL. Integration of additive pumps for remote operation, level measurement shall be in the successful bidder's scope.

-

-

-

... More
Supply of Layer 3 Managed Gigabit Ethernet Switch with minimum 24 ports or as per site requirement + 20 % spare whichever is higher along with SFP, copper, fibre modules, accessories complete as per specifications and Tender Document. Note- The switches are required to be configured in dual redundant mode

2

801191

-

... More
Installation, Integration, Configuration, Testing and Commissioning of minimum 10 ports ( 8 nos. copper ports and 2 nos optical ports) Layer 2 Industrial grade Managed Ethernet Switches along with accessories for connecting BCU with TAS, equipments installed in S&D room, Lock room, Security room, Terminal Manager room and other TAS equipments as per system architecture and design requirement complete as per specification and tender document. Note: 1. Ethernet switches for BCU communication shall have suitable mounting arrangement to mount inside FLP JBs. 2. The switches are to be configured in Dual Redundant mode. 3. All OICs, Workstations, Servers other than that of CCTV, ACS & TFMS are to be connected to both plant management and plant control LAN so that all the GUIs can be seen in all the PCs irrespective of its nomenclature like TTES, OIC, EWS, TM PC etc. 4. Printers to be connected to Plant Management LAN and to be configured to all PCs, Workstations, TTES etc so that printout command can be issued from any of the Machine.

-

-

-

... More
SPD (Type 2 / IC category C1,C2,C3,D1) - Serial port of MCS (RJ45/DB-9 type)

30

265464

-

... More
Design, Engineering, Installation, Setup, Configuration, Integration, Testing & Commissioning of redundant fault tolerant Integrated Distributed Control System (DCS) along with DCS Panels, Marshalling Panels, Biometric fingerprint cum contactless smart card reader with accessories, limit switches, Input Output modules, Power supply units, Relays with base, barriers, TBs, Redundant host communication ports, Serial Interface Modules, HART modules, any other communication modules, HMI, wirings, glands, plugs, other modules/ hardware required for interfacing all the required field and control room equipments including spare requirements, licenses, tags, GUI, licensed OPC compliant software etc complete as per specification and tender document. Note: Any other hardware, software, OPC server, Historian Server, storage, firewall, functional control key board etc required as per tender specification and design requirements, the same to be provided by the vendor at no additional cost to IOCL.

1

132032

-

... More
Access Control System

-

-

-

... More
3P x 1.5 sqmm

300

63366

-

... More
IP BASED CCTV SURVEILLANCE SYSTEM

-

-

-

... More
Installation, Configuration, Integration, Testing and Commissioning of flameproof cum weather proof to IP 65 or better bi-colour magnetic flap type level gauge (side mounted) along with level transmitter with installed accuracy +/- 6 mm or better along with mounting accessories, complete as per specification and tender document.

-

-

-

... More
Validation of entire Safety System (SIS) for SIFs (for e.g. AOPS -SIF) shall be carried out from approved third party agency prior to trial period. Automation contractor shall bear the responsibility of its co-ordination and logistics. The third party has to submit a detailed report along with certification for SIS which is to be approved by IOCL along with all other required documentation as per specification and tender documents.

1

384848

-

6

58544

-

... More
Installation, Integration, Testing and Commissioning of Engineering Workstation (EWS) with minimum 27" colour LED monitor, standard keyboard, mouse, PLC & DCS software, HMI software, SCADA, GUI, OS, Antivirus, MS office professional etc. complete as per specifications and tender document. (Locations: 1 no. in CR for both DCS and Safety PLC) Note: CPU shall be kept in Panel room in 42 U Rack. KVM extender & reciever is to be supplied at no additional cost

-

-

-

... More
Supply of one no. of Portable Hydrocarbon vapour detector along with accessories complete as per specification and tender document.

1

352183

-

... More
Supply of outdoor Explosion proof cum weatherproof housing (IP 65 or better) suitable for installing Layer 2 switch, PSU, LIU and adaptor for Ethernet switch/media convertor surge protectors and other accessories of PA Paging. The scope also includes supply of Exd. Blinding plugs, LIU, OFC accessories, Exd. double compression cable glands etc. as per specification & tender documents.

16

492447

-

... More
DG Set Service Tanks

3

243626

-

... More
Resident Engineer support on quarterly basis in case of shift addition during CAMC period

4

1192526

-

... More
6P x 1.5 sqmm

4000

1298000

-

... More
Cabling, JB, Earthing:

-

-

-

... More
Access Control System

-

-

-

... More
Fourth Year @3% of the basic CAPEX cost

1

14134827

-

... More
Supply of IP based Desktop phone Min 4” Color TFT Display, soft keys with LED, 3 audio keys (Mute/Speaker/Headset) with LED, Bluetooth 2.1 BR/EDR, IEEE 802.3af PoE, Class 2, 10/100/1000 Base T.

1

31300

-

... More
Main Gate Entry (For Vehicles other than TT)

1

263777

-

... More
Supply of ESD push button stations (for indoor application), mushroom head type with protection cover to avoid accidental activation along with mounting structure complete as per specification and tender document. (Plant ESD at (i) control room - 1 no., (ii) security room - 1 no., (iii) TM's cabin - 1 no.)

3

38978

-

... More
Supply of addressable type detectors along with accessories, fault isolation module (Inbuilt), structural supports etc required as per standard design engineering, specification and tender document complete in all respect.

-

-

-

... More
TTPA Exit gate

1

19479

-

... More
Installation and fixing of Open desk operator consoles, chairs, printer tables etc complete as per specification and tender document.

-

-

-

... More
Installation, testing and commissioning of Additive tanks (500 Litres each) and pump module for XTRAPREMIUM /XTRAGREEN comprising of Additive Tank, Additive Pumps (Two per tank) , Mild Steel SKID, flameproof cum weather proof, min SIL 2 certified smart pressure transmitter with display unit & keypad, SS manifold, 1 no. isolation ball valve,flameproof cum weather proof to IP 65 or better SIL 2 Smart Differential pressure transmitter with in built display, SS 5 way manifold, Flameproof Motor, NRV 25 mm, Flanged ball valve 25 mm, Pressure Relief Valve, Pressure Gauge with pulse dampener, Strainer 25 mm, interconnecting pipings (25 mm SS), flanges etc. auxiliary potential free contact/serial communication complete as per specification and tender document.

-

-

-

... More
4P x 0.75 sqmm

130

4908

-

... More
License area Exit gate

2

38958

-

... More
SKO-0.6 KL

1

536721

-

... More
3C x 2.5 sqmm

100

15576

-

... More
18P x 1.5 sqmm

6400

407808

-

... More
3P x 1.5 sqmm

300

10974

-

... More
3C x 4 sqmm

100

4366

-

... More
Installation, integration, testing and commissioning of 4 port Industrial grade layer 2 Managed POE based Ethernet Switch for connecting ACS readers with 4 Nos. RJ copper port and 2 Nos. optical fibre ports with inbuilt/external surge protector (Type 1+2) at the input power supply as per specifications and Tender Document.

10

31258

-

... More
16 ports at Control Room

2

6442

-

... More
ESD PUSH BUTTON STATION

-

-

-

... More
Installation, integration, configuration, testing and commissioning of Outdoor Field Call Station : • Connection to Fast‐Ethernet network, power supply via PoE function • SIP‐connections support • Priority levels setting • Easy maintenance and remote administration • LED indications for incoming, missed call and line status (busy) • Noise reduction/elimination adjustable microphone • 25W amplifier for additional loudspeaker • Identification label • Hot swapping • Protection degree Min. IP65 Installation, integration, configuration, testing and commissioning of Weatherproof (IP65) industrial wall-mounted call station IP based for two-way communications, with Dial keypad, Handset ,status indication, identification label,25 W amplifier for additional loudspeaker with mounting accessories, sunshade, Double compression EXD Glands and EXD blind plugs complete as per specification and tender documents.

7

155857

-

... More
Supply of LED monitor of minimum 55" along with required hardware and software for interfacing with TAS, lockable enclosure (wall / ceiling mounted) for mounting the monitor along with accessories at Driver's Rest Room for repeat display of Bay Queue Display board complete as per specification and tender document. Kindly note, no additional payment shall be made for any additional hardware/ software/ cable etc required for integration of the monitor with TAS.

1

293941

-

... More
Installation, configuration, integration, testing and commissioning of Colour photo pass printer along with integrated/seperate scanner for photo pass printing as per specification and tender document.

2

4540

-

... More
Installation, testing and commissioning of 350 W LED flood ONLY light luminaries on Light poles up to 10M height including supply & fixing of clamps, scafolding , temporary fire screen ifrequired, supports, nuts,bolts, earthing , required modification infixing arrangement , Supply and welding of mounting structure as persite condition , painting etc. all complete with labour and materials asper drawings, specifications and directions of the Engineer-in-Charge.

48

268360

-

... More
Installation, Integration, Testing and Commissioning of Multistage Piston type Digital Control Valve (DCV) with secure locking arrangement of the needle valves to avoid manual throttling of the needle valves after final tuning of the DCV has been done, secure key etc along with accessories complete as per specifications and tender document.

-

-

-

... More
Tower mounted type in Invoice room (1 no.)

1

3501

-

... More
Installation, testing and commissioning of industrial grade redundant Serial to Ethernet converter of 8 port with mounting acessories etc complete in all respect as per specification and tender document. (Ports:- 6 Main + 2 Spare)

-

-

-

... More
Supply of Access Control cum photopass management System Software for setup, configuration, operation, events, history and archiving, alarm monitoring, recording, printing, time and attendance etc. complete as per specification and tender document including hardwired interface with TAS for ESD input.

1

526711

-

... More
Supply of 6W weather proof Box type Speaker and mounting accessories etc complete as per specifications and Tender Document. Type : Indoor, Wall Mountable, suitable for speech and music reproduction Rated power : 6W Frequency range : 20 Hz TO 20 KHz Ingress protection : IP 52 Standard : EN 60065

1

5472

-

... More
2C x 1.5 sqmm

3800

134520

-

... More
Design, Fabrication, erection, weld, painting, cutting, drilling, grinding etc of Structural steel (MS) for erection of cable bridge (if required) for laying of above ground cables at road crossing or any other place within the Terminal including painting, Civil foundations, nuts, bolts, washers, cleats, stiffners, gussets, base plate etc

10

359711

-

... More
MS (for line size of 100 mm)

4

21570

-

... More
Installation, configuration, integration, testing and commissioning of Redundant ACS Server for photo pass management & visitor management (19" Rack type at panel Room, form factor - Rack, CPU height - 2U) with minimum 19" colored LED monitor, KVM switch, keyboard, mouse, OS, Antivirus etc located in Control Room complete as per specifications and Tender Document.

1

4895

-

... More
Supply of the NMS System covering Network Devices operational in Terminal Automation System. The Offered Network Management Solution (NMS) solution should support at least the following: • All the proposed NMS Components should be from single vendor. • NMS Software should support Graphical view up to port level for the all the devices. Discovery of Network Elements. • Real time Traffic monitoring of Network Links and Devices with Historical reports for various periods. • Management of SNMPv1, SNMPv2, SNMPv3 & MIB etc. • Configuration of thresholds for Generating alarms. • Configuration of alarm actions (visual, audible, email, sms etc.) for each Network element. • Should be able to provide secured windows based consoles / secured web based consoles for accessibility to NMS. • Should have web browser interface with user name and Password Authentication. • Administrator/ Manager should have privilege to create/modify/delete user. • NMS should have support for SNMPv3 & IPv6, including dual-stack IPv4 & IPv6 to provide flexibility in protocol strategy and implementation.

1

1268468

-

... More
3C x 1.5 sqmm

100

11446

-

... More
36C x 1.5 sqmm

100

86730

-

... More
Supply of Triple Offset Butterfly valve with electrical/electro-hydraulic fail safe actuator for ON-OFF operation along with accessories as per installation drawing etc for line size 100 mm complete as per specifications and tender document.

12

4888570

-

... More
Installation, integration, testing and commissioning of half man height bi-directional turnstile (tripod) with controller along with accessories, mounting structure, pressure sensor etc required as per standard design engineering, specification and tender document complete in all respect. (Location : Pedestrian Entry/Exit Platform to tank farm area - 4+ Pedestrian entry/exit platform near TLF entry/exit gate 2 nos. ; )

6

69766

-

... More
300 mm

1900

3526666

-

... More
Fire Engine Service tanks

2

162417

-

... More
For Vertical Product tanks

7

30215

-

... More
Rack Type - CPU in panel room with KVM sitch; Keyboard, mouse along with monitor etc. to be installed in security room for visitor pass

1

5228

-

... More
Supply of Manual Call Point along with accessories, fault isolation module (Inbuilt/ External) and structural supports etc required as per standard design engineering, specification and tender document complete in all respect.

-

-

-

... More
IS detector

5

6773

-

... More
Tank Farm Management System

-

-

-

... More
Supply of flameproof cum weather proof to IP 65 or better SIL 2 Smart Differential pressure transmitter with in built display, SS 3 way manifold, SS canopy/sunshade, other erection material etc as per hook up drawing attached else where in tender complete as per specifications and Tender Document. (Transmitter will have IEC/ATEX certified minimum and any other certification as stated else where in tender)

-

-

-

... More
Installation, Integration, Configuration, Testing and Commissioning of 24 ports Layer 3 Managed Ethernet Switches (10/100/1000 MBPS) with SFP, copper, fiber modules/ports along with accessories for connecting Plant management LAN equipments like CCTV System, TAS - MS Server/ Redundant OPC server, TFMS Server, TFMS work station, OICs, IOCL intranet for SAP connectivity through fire wall, Network printers, Access Control Server, Web Server Access over IOCL Intranet, connecting to OIC/ work stations etc which needs to be connected to both Plant Management LAN and Plant Control LAN for getting the entire GUIs of Complete Terminal Automation System and any other third party devices which needs OPC for interfacing with DCS etc. Note: 1. Ethernet Switches to be configured in Dual Redundant mode. 2. OFC ports to be provided for connecting interbuilding LANs and any other equipment which are to be connected to above switch and the communication is through OFC cable.

2

6251

-

... More
10P x 1.5 sqmm

2100

1177050

-

... More
RON Additive Pump Suction and Discharge end

4

12111

-

... More
Installation, Testing and Commissioning of online proving valve manifold comprising of 1no. manual operated DBBV and 2 nos. of 100 NB, full bore, zero leakage, fire safe ball valves along with associated piping, Tee connection, gaskets, copper jumpers, fasteners, blind flanges at one end of each ball valves, pipe fittings, WNRF flanges etc for each loading point assembly for making arrangement to connect Mobile master meter for proving of TLF MFM complete as per specifications and tender documents.

12

89689

-

... More
Installation, configuration, integration, testing and commissioning of IP Fixed Box cameras with varifocal lens (8MP) – 4K resolution along with power supply unit (POE based), with inbuilt/external surge protection unit and mounting accessories etc complete as per specifications and Tender Document.

48

244401

-

... More
For mounting of Network equipments along with power adaptors, MCBs, required accessories etc as per specification and tender document.

1

147108

-

... More
For Water Tanks

2

16175

-

... More
Supply of Exd/FLP Local Push button station cum indication lamp out side tank farm dyke wall for remote opening and closing of valves from LPBS, along with FLP double compression gland, TBs, mounting structure, accessories etc complete as per specifications and tender document.

-

-

-

... More
2P x 1.5 sqmm

3200

664576

-

... More
Supply of Exd/FLP Junction Box (Power/Control/Signal JB) with IP 65 as per specification suitable for hazardous area of zone 1, group IIA/IIB, T3 or better having CCOE/CMRI approval. It shall be complete in all respect. Accessories like certified double compression cable glands with PVC shrouds & plugs for excess entries, SS 316 engraved tag plate, mounting clamp & SS 316 fasteners. Complete as per specification / tender documents.

-

-

-

... More
SKO-0.6 KL

1

7445

-

... More
Main Gate Exit (For Vehicles other than TT)

1

19479

-

60

129493

-

... More
19" Rack mounted at Control Room, Form factor - Rack , Max. 2U height

1

4417

-

... More
Near TT Parking Area ( for TT reporting/registration )

2

109128

-

... More
Installation, Integration, Testing and Commissioning of Tank Side indicator along with mounting accessories etc complete as per specification and tender document for displaying respective tanks inventory data. (TSI will have IEC/ATEX certified minimum along with any other certification as stated else where in tender)

-

-

-

... More
Rack type (2 U) (i) without colored LED monitor - Control Room - 1 no. ,

1

6230

-

... More
4C x 6 sqmm

2750

107085

-

... More
6 ways JB

80

833646

-

... More
Installation, Configuration, Integration, Testing and Commissioning of Wailing siren along with controller with a provision to operate locally as well as from control room, mounting accessories etc complete as per specification and tender document.

1

8408

-

... More
Across Strainers in RON additive pump

2

121386

-

... More
3.5C x 120 sqmm

800

479552

-

... More
Supply of flameproof cum weather proof, min SIL 2 certified smart pressure transmitter with display unit & keypad, SS manifold, 1 no. SS isolation ball valve, SS canopy/sunshade with mounting accessories etc on the TLF metering skid complete as per specifications and tender document. (Transmitter will have IEC/ATEX certified minimum along with any other certification as stated else where in tender) (Range 0-15 kg/cm2)

6

287660

-

... More
Installation, Integration, Testing and Commissioning of top mounted minimum SIL2 certified Overfill detector (vibrating fork type) of suitable probe length along with mounting accessories, spool piece of minimum 500mm ( Both for AG and UG Tanks), proof testing equipment etc complete as per specification and tender document

-

-

-

2

16175

-

... More
3C x 4 sqmm

6100

230336

-

... More
For BCU integration at TLF (copper ports of 10/100/1000 MBPS)-( Minimum 8 nos. copper ports and 2 nos. optical ports)

2

204496

-

... More
Supply of Density probe along with accessories etc for density measurement of the product in product tanks complete as per specification and tender document. (Transmitter will have IEC/ATEX certified minimum along with any other certification as stated else where in tender)

-

-

-

... More
Installation, integration, Calibration, Testing, and Commissioning Flameproof cum weather proof (IP 66 or better) min SIL 2 certified Hydrocarbon gas detectors along with calibration kit, accessories and structural supports etc as per specification and tender document.

-

-

-

60

33771

-

... More
Supply of Outdoor Field Call Station : • Connection to Fast‐Ethernet network, power supply via PoE function • SIP‐connections support • Priority levels setting • Easy maintenance and remote administration • LED indications for incoming, missed call and line status (busy) • Noise reduction/elimination adjustable microphone • 25W amplifier for additional loudspeaker • Identification label • Hot swapping • Protection degree Min. IP65 Supply of Weatherproof (IP65) industrial wall-mounted call station IP based for two-way communications, with Dial keypad, Handset ,status indication, identification label,25 W amplifier for additional loudspeaker with mounting accessories, sunshade, Double compression EXD Glands and EXD blind plugs complete as per specification and tender documents.

7

1015203

-

... More
Security Block Exit gate - Near Invoice room

1

19479

-

... More
Supply of minimum 24 ports Layer 2 Managed Ethernet Switches (10/100/1000 MBPS) along with SFP, copper, fibre modules, accessories for connecting equipments installed in Plant Control LAN like TAS- MS Servers, OICs, TTES cum TWES , EWS, OPC Servers, Fire fighting OICs, Alarm Display OIC, DCS, Safety PLC, inter connecting building work stations etc as per system architecture and design requirement complete as per specification and tender document. Note: 1. The switches are to be configured in Dual Redundant mode. 2. OFC ports to be provided for connecting interbuilding LANs, and any other equipment which are to be connected to above switch and the communication is through OFC cable Note: Suitable no. of wireless Access Points to be provided for having wireless connectivity in whole Control Room at no additional cost to IOCL.

2

682235

-

... More
36C x 1.5 sqmm

1500

1035450

-

... More
Supply of FS Armoured Copper Signal cable as per tender specifications.

-

-

-

... More
Supply of Strainer cum Air eliminator with differential pressure transmitter across the Strainer along with accessories, SS tubing, needle valves etc complete as per specifications and tender document.

-

-

-

... More
Installation, integration, configuration, testing and commissioning of Amplifier with mounting accessories for indoor speakers complete in all respect as per technical specification of tender.

2

85321

-

... More
Submission of Final Detailed system design, Engineering, Documentations, as built drawings etc complete as per tender

1

151217

-

... More
Hydrocarbon Detection system

-

-

-

2

10834

-

... More
Installation of 2"size SS 304 guiding rail along with mounting accessories complete as per specification and tender document near turnstile/ tripod/flap barrier etc to prevent un-authorised movement.

100

61006

-

... More
Supply of top mounted minimum SIL2 certified Overfill detector (vibrating fork type) of suitable probe length along with mounting accessories, spool piece of minimum 500mm ( Both for AG and UG Tanks), proof testing equipment, etc complete as per specification and tender document

-

-

-

... More
ETHANOL-0.6 KL

1

7445

-

... More
For Vertical Product tanks - (Primary & Secondary Radar Gauges)

14

744738

-

... More
ETHANOL

3

1063571

-

... More
12C x 2.5 sqmm

3000

130980

-

... More
Supply of IP Fixed Bullet cameras with MFZ lens (8MP) – 4K resolution along with power supply unit (POE based), with inbuilt/external surge protection unit and mounting accessories etc complete as per specifications and Tender Document.

32

3526897

-

... More
Supply of Digital Rodent Repellent System along with mounting accessories for main controller(s) & transducers etc complete as per specification and tender document (Minimum nos of transducers: Main gate Security Room- 4 nos)

1

59521

-

... More
Push Button station for operation of MOVs in OWS line

-

-

-

... More
IP BASED CCTV SURVEILLANCE SYSTEM

-

-

-

... More
Sixth Year @4% of the basic CAPEX cost

1

18846436

-

... More
Across Sludge/Stripping Pumps Strainers---Remote Seal Type

2

121386

-

... More
Installation, Testing and Commissioning of bottom loading arm of size 100 mm NB along with 1 no. full bore isolation ball valve (100 mm), API Coupler, break away coupler, parking stand with compatible API adaptor, Ex-proof/intrinsic safe position sensor for parking stand, TRV with two nos. of isolation valves at inlet and outlet of TRV, associated piping for connecting loading arm with the metering skid & TRV outlet to nozzle before ON-OFF valve, mounting structure etc complete as per specifications and tender document. Application: MS, HSD

10

114979

-

... More
RON Additive

2

496407

-

... More
4P x 1.5 sqmm

9500

2466200

-

... More
U/G Slop Oil

1

489487

-

... More
Local Area Network (LAN) works

-

-

-

... More
For MOVs in OWS line

26

68201

-

... More
Supply of Bulk Air Eliminator as per product line size and flow requirement (Min. capacity 1.6 KL) including mounting structure, foundation etc complete as per specification and tender document.

-

-

-

... More
Installation, testing and commissioning of weather proof and Explosion proof Hooter cum beacons/ flash light along with accessories and structural supports as per specification. ( Tentative location : Each product tank dyke-(3 )nos., Near TLF and TW Pump House -2 no. & Vapour recovery system-1no., OWS/ETP - 1 no.)

7

27167

-

... More
24C x 2.5 sqmm

6000

283200

-

... More
4P x 1.5 sqmm

100

4248

-

... More
Installation, integration, configuration, testing and commissioning of Solenoid valves (SOV) of 25 /32/50/65 NB (as per line size) along with 3 no. of isolation by pass valve with complete pre-fabricated assembly to bypass the SOV with associated piping, mounting accessories etc complete as per specification and tender document. Note: SOV need to be supplied factory fitted along with baypass valve and both side flanged option.

-

-

-

... More
Installation, integration, testing and commissioning of flameproof cum weather proof, min SIL 2 certified smart pressure transmitter with display unit & keypad, SS manifold, 1 no. SS isolation ball valve, SS canopy/sunshade with mounting accessories etc on the TLF metering skid complete as per specifications and tender document. (Transmitter will have IEC/ATEX certified minimum along with any other certification as stated else where in tender) (Range 0-15 kg/cm2)

6

24171

-

... More
Installation, integration, testing and commissioning of Door Frame Metal Detector (Main Gate Security room entry- 1 no, TLF entry from main gate-1 no, TLF entry from TTPA-1 no, License area entry gate-1 no) along with accessories, mounting structure etc complete as per specification and tender document.

2

19250

-

... More
Fire Engine Suction and Discharge end

4

191773

-

... More
19" Rack type at Control Room, form factor - Rack, CPU height - 2U ( 3 OICs, 1 for fire fighting System)

4

20347

-

... More
Installation, integration, configuration, testing and commissioning of Turbine Flow Meter (40/50 MM) with pulse transmitter and field totalizer unit in n Flameproof and Weather Proof (Min. IP 65) enclosure along with two number of SS ball valve, strainer cum aireliminter (50 mm) and associated piping as tender specification and mounting accessories complete as per specification and tender document. Note: For HSD Meaurement to pipeline division.

2

27262

-

... More
Installation, testing and commissioning of SKO Blue Dye Dosing Skid comprising of 1 no. SS Blue dye tank of Min. capacity of 500 Ltrs, Blue Dye dosing pumps of minimum capacity of 200 LPH along with Flameproof Motor (2 Nos.) , 1 no. agitator with FLP motor, Mild Steel Skid, NRVs, Flanged SS ball valves, Pressure Relief Valve, pulse dampener, Pressure transmitter with inbuilt display unit and keypad, solenoid valves (4 nos.), Turbine flow meters (2 nos. - for calculating the volume of SKO receipt into blue dye tank and volume of diluted Blue dye dosed into SKO receipt header line), Rotameter, Strainer with DPT, piping, flanges, auxiliary potential free contacts/serial communication for remote operation and feedback of the pumps, starter etc. complete as per specifications, drawing and tender document. Note: Blue dye to be injected in SKO receipt header line during product receipt. Provision to be made for diluting the blue dye with SKO tapped from the main receipt line before dosing as per drawing , Auto flushing of blue dye dosing system complete as per specification and tender document.

1

20956

-

... More
3C x 2.5 sqmm

27000

955800

-

... More
For mounting of CCTV Servers, Analytics Servers, NAS/SAN along with associated rack mounted monitors, Rack mounted keyboard, mouse, 4 port industrial grade KVM switches, power adapters, layer 3 Ethernet switch, MCBs etc as per specification and tender document.

2

294216

-

... More
Note: 1. All the equipments, JBs, cable trays, interconnecting cables etc as stated above to be installed and loop tested at factory. Complete assembly to be dispatched at site. The skid to be designed and fabricated by the party taking into consideration of all the equipment sizing, space available for mounting of the skid at the bottom of the gantry etc. The design Engineering along with weight calculation of individual skid excluding equipments to be submitted to IOCL prior to taking up fabrication job for review purpose. Payment shall be made based on theoretical weight calculation of the skid excluding weight of equipments, JBs and cable trays. The rate is also inclusive of surface preparation, powder coating, painting, transportation of the skid to site etc complete in all respect. 2. All unuse nozzle/ tapping/ opening to be blind flanged. 3. For SKO metering SKID, tapping to be provided in the skid for both bottom and top loading as per design Engineering. (if applicable)

-

-

-

... More
Supply of 6W weather proof Ring type Speaker and mounting accessories etc complete as per specifications and Tender Document. Type : Indoor, Ceiling Mountable, suitable for speech and music reproduction Rated power : 6W Frequency range : 20 Hz TO 20 KHz Ingress protection : IP 52 Standard : EN 60065

25

161424

-

... More
- Valve Automation (ROSOVs, MOVs, DBBV, MCS Interface, SOVs, etc) '-Tank Farm Management System ( TFMS Server, Primary & Secondary Radar Gauging, AOPS, Level transmitters, Level Switch, Density probes, MSTW, CIU etc) - MCC, Pump, Borewell, DG Sets, Air compressors, VFDs - PA paging Interface - HC Detection System Interface -FAS Interface, Fire Fighting System, HVLR, Fire Alarm System Interface, Fire Engines, DG Sets, Jockey pumps, Foam pumps, CFFS, Sprinkler & Fixed foam pourer system etc - VRU Package Units -Effluent Treatment plant - CCTV systems - Access Control System - SKO Blue Dye Dosing System - ESD System, Emergency panel, Power ESD, Local ESD, Wailing sirens -Pressure Transmitters - UPS & Power distribution boards etc - Interface with IOCL SAP through firewall - Any other Third Party Interface/ devices as per scope of the work order etc Note: The offered software also includes fault detection module and Web Server software for remote viewing over IOCL Intranet across India as detatiled in the tender document.

-

-

-

8500

2597770

-

... More
Supply of FS Armoured Copper Control cable as per tender specifications.

-

-

-

... More
CCTV System

12

147037

-

... More
Hydrogen Detector

7

9482

-

... More
At the inlet of HVLR tanks

4

9756

-

... More
For mounting of Rack mounted Master Control Stations for MOVs & DBBVs along with power adaptors, MCBs, required accessories etc as per specification and tender document.

2

294216

-

... More
32C x 1.5 sqmm

1500

1341660

-

... More
HCD addition (OPD/PTD)

1

135703

-

... More
Supply of anodized Aluminium perforated cable trays (2.5mm Thick and 25mm edge height), tray covers (1.5mm Thick and 10 mm edge height) along with structural steel for mounting of the cable tray. Complete as per specifications / tender documents.

-

-

-

... More
Raw water sump

1

4310

-

... More
8T x 1.5 sqmm

2450

141659

-

... More
At Security Room near Invoice Room - copper ports of 10/100/1000 MBPS [Control LAN- 2 Nos ] (Minimum 8 nos. copper ports and 2 nos. optical ports)

2

6251

-

... More
10C x 1.5 sqmm

3400

818448

-

... More
Installation, Integration, Testing and Commissioning of Multistage Piston type Digital Control Valve (DCV), NRV, isolation valve for line size 50 mm alongwith accessories, with secure locking arrangement of the needle valves to avoid manual throttling of the needle valves after final tuning of the DCV has been done, secure key etc along with accessories complete as per specifications and tender document.

4

19861

-

4

39029

-

... More
Supply of CCTV client work station along with client software & licenses, key board, mouse, hardware & connector for repeat/ Dual display on wall mounted LED screen, OS, Antivirus, etc complete as per specifications and Tender Document. Note: CCTV Work station shall have provision to connect to 2 nos. of UHD LED monitors . Required hardware & software is to be provided for the same. Incase the offered work station do not have such provision, then additional work station to be provided meeting the tender requirement at no additional cost to IOCL.Marketing CPU for control room & security room shall be kept in Panel room in 42 U Rack. KVM extender & reciever for these CPU is to be supplied at no additional cost.

-

-

-

... More
Supply of top loading arm of size 100 mm NB along with 1 no. full bore isolation ball valve (100 mm), associated piping for connecting loading arm with the metering skid & TRV outlet to nozzle before ON-OFF valve, mounting structure etc complete as per specifications and tender document. Application: SKO

2

636331

-

... More
Installation, configuration, integration, testing and commissioning of Access Control cum photopass management System Software for setup, configuration, operation, events, history and archiving, alarm monitoring, recording, printing, time and attendance etc. complete as per specification and tender document including hardwired interface with TAS for ESD input.

1

2299

-

2

10834

-

... More
Supply of 24 ports Layer 3 Managed Ethernet Switches (10/100/1000 MBPS) with SFP, copper, fibre modules/ports along with accessories for connecting Plant management LAN equipments like CCTV System, TAS - MS Server/ Redundant OPC server, TFMS Server, TFMS work station, OICs, IOCL intranet for SAP connectivity through fire wall, Network printers, Access Control Server, Web Server Access over IOCL Intranet, connecting to OIC/ work stations etc which needs to be connected to both Plant Management LAN and Plant Control LAN for getting the entire GUIs of Complete Terminal Automation System and any other third party devices for interfacing with DCS etc. Note: 1. Ethernet Switches to be configured in Dual Redundant mode. 2. OFC ports to be provided for connecting interbuilding LANs and any other equipment which are to be connected to above switch and the communication is through OFC cable.

2

1045652

-

... More
Supply of reduntant server (Rack type) computer with 19" rack mounted Rack type monitor, with keyboard drawer, optical mouse, OS, Antivirus, etc. complete as per specification and tender documents.

1

956136

-

... More
CCTV System

12

295391

-

... More
PLANT COMMUNICATION SYSTEM

-

-

-

... More
Weather proof MCP

25

238153

-

... More
2C x 1.5 sqmm

3800

349752

-

... More
For Cone Roof Vertical tanks (Primary and Secondary Radar Gauges)

-

-

-

... More
RON Additive Pump Suction and Discharge end

4

191773

-

... More
At the inlet of HVLR tanks

4

125570

-

... More
For XtraPremium

1

15960

-

... More
For mounting of CCTV Servers, Analytics Servers, NAS/SAN along with associated rack mounted monitors, Rack mounted keyboard, mouse, 4 port industrial grade KVM switches, power adapters, layer 3 Ethernet switch, MCBs etc as per specification and tender document.

2

12533

-

... More
Type 1+2 SPD

4

36580

-

... More
Supply of 1C x 6 Sq. mm FRLS Flexible copper insulated green wire for earthing instruments and junction boxes etc complete as per specification and tender document

30000

2124000

-

8500

4162450

-

... More
8C x 2.5 sqmm

10500

3209010

-

... More
Supply of Ex-proof field mounted Remote Interaction Terminal (RIT) cum Driver Ack Push Button station along with FLP double compression glands and Ex-Proof-plugs, structural supports etc complete as per specifications and tender documents.

1

15819

-

... More
Supply of 2+1(3) KL combined Stainless Steel Mobile Prover tank along with accessories like flanges, SS ball valves, calibrated sight glass, plunger, hoses, blind flanges, etc mounted on Trailer chassis along with wheels with solid rubber tyres complete as per specifications and tender document. Note: Vendor to arrange for prime mover for calibration of MFM at site during entire commissioning and CAMC period at no additional cost to IOCL.

1

1251179

-

... More
Supply of RFID reader for vehicle identification along with canopy and structure for installation of the reader as per specification and tender document (Main Gate Security room - 1*2 =2)

2

149260

-

... More
Product code change

1

131613

-

... More
Supply of Wall mounted/wheel mounted Network Rack - Minimum 19U 19" Rack for mounting of Terminal Server/Ethernet switches/LIU/ OFC components along with accessories like power sockets, MCBs, fan, mounting accessories etc complete in all respective at (i) Admin Building

1

106692

-

... More
3C x 1.5 sqmm

100

13452

-

... More
For mounting of Network equipments along with power adaptors, MCBs, required accessories etc as per specification and tender document.

1

6421

-

... More
Additive dosing System

-

-

-

... More
Installation, configuration, integration, testing and commissioning of Network Attached Storage ( NAS ) / Storage Attached Network (SAN) for storing recorded video for a minimum period 90 days @ 15 FPS at full resolution & highest Video quality of all cameras (Continuous recording) complete as per specifications and Tender Document.

725

3149951

-

... More
Local ESD Push Button Station ( Each Battery of TLF -1X1 no., TLF pump house - 1 no., TW Pump House - 1 no., Tank Wagon Area - 13 no.)

16

207887

-

... More
Supply of Magentic Flow Meter in water line in outlet of borewell along with two number of SS ball valve and associated piping as tender specification and mounting accessories complete as per specification and tender document.

1

152865

-

... More
18C x 1.5 sqmm

250

12390

-

... More
Supply of Exd/FLP ESD push button stations, mushroom head type, with protection cover to avoid accidental activation along with mounting structure complete as per specification and tender document. ( For 16 bays)

8

42659

-

... More
DISPLAY BOARDS

-

-

-

... More
Conducting Fire and Hydrocarbon vapour Mapping study through reputed agencies having proven track Record of conducting similar studies for oil Installations across the globe, using standard licensed software along with submission of study reports as per specification and tender document. The agency carrying out Dispersion study has to necessarily visit the site before finalizing its report.

1

976313

-

... More
Installation of Wall mounted/wheel mounted Network Rack-minimum 9U 19" Rack for mounting of Terminal Server/Ethernet switches/LIU/ OFC components along with accessories like power sockets, MCBs, fan, mounting accessories etc complete in all respective at (i) Main Gate Security Room, (ii) Security room near Invoice Room,(iii) TT crew rest room

3

13682

-

... More
Supply of Tank Side indicator along with mounting accessories etc complete as per specification and tender document for displaying respective tank inventory data. (TSI will have IEC/ATEX certified minimum along with any other certification as stated else where in tender)

-

-

-

... More
Hydrogen Detector

7

737394

-

... More
Supply of Network Attached Storage ( NAS ) / Storage Attached Network (SAN) for storing recorded video for a minimum period 90 days @ 15 FPS at full resolution & highest Video quality of all cameras (Continuous recording) complete as per specifications and Tender Document.

725

8529335

-

... More
Supply of Engineering Workstation (EWS) with minimum 27" colour LED monitor, keyboard, mouse, KVM Switch, Safety PLC & DCS software, HMI software, SCADA, GUI, OS, Antivirus, MS office professional etc. complete as per specifications and tender document. (Locations: 1 no. in CR for both DCS and Safety PLC) Note: CPU shall be kept in Panel room in 42 U Rack. KVM extender & reciever is to be supplied at no additional cost

-

-

-

... More
For U/G Tanks with 1 elements

-

-

-

... More
6C x 1.5 sqmm

4300

715434

-

4

39029

-

... More
Security barrier gates (TTPA Entry/Exit gate- 2 no and Entry/Exit Gate of Security Block near Invoice Room - 2no. )

4

218257

-

... More
Design, development, modification, configuration, testing and commissioning of existing TAS software, DCS/PLC logic, GUI etc for implementation of following features after SAT (if required) or during CAMC period as stated in tender document. The job includes necessary tro-& fro travel, lodging, boarding, food etc required for implementation at site complete in all respect and as per direction of EIC.

-

-

-

... More
4C x 4 sqmm

100

28556

-

... More
TTPA Entry gate

1

19479

-

... More
Supply of Mobile Master meter (Master MFM) proving system for line size 100mm consisting of Master Mass flow meter with display unit, Master Temperature Transmitter with RTD with Thermo-well, Mounting accessories suitable for installation on 4" line size, 2 nos. isolation ball valve of 100 mm, Two number swivel joints on ends,hose pipe, trolley mounted Master Meter Skid with suitable wheels, FLP JB, FLP double compression glands, power & signal adapter along with accessories for Master Meter, FRLS Copper Power & Signal Cable (Retractable Type) of minimum 10 m or as per site requirement with compatible FLP plugs for MFM along with integration of Mobile Master MFM with TAS and integration of temperature transmitter with Master MFM, supports for mounting the equipments, pipes, flanges, reducers, gaskets, nuts, SS bolts & studs etc complete as per specification and tender document.

1

1571341

-

... More
For XtraPremium

1

1014279

-

... More
Supply of FRLS Un-armoured Copper Signal cable as per tender specifications.

-

-

-

... More
EPABX & TELEPHONE System

-

-

-

... More
Installation, Integration, Testing and Commissioning of Ex-proof field mounted Remote Interaction Terminal (RIT) cum Driver Ack Push Button station along with FLP double compression glands and Ex-Proof-plugs, structural supports etc complete as per specifications and tender documents.

1

2503

-

... More
For Primary Radar gauges installed on A/G product tanks, under ground product tank, water tank & Sludge tank

1

1051564

-

... More
First Year - Warranty

-

-

-

... More
Supply of Intelligent video operation, control, management, recording & processing software (VMS) complete as per specifications and Tender Document with minimum 200 cameras recording, 200 cameras viewing license, 5 LISC licence for remote viewing or as per actual nos. of cameras installed + 20% extra which ever is higher.

1

1408483

-

... More
Supply of Tank Truck Entry System (TTES) Workstation with minimum 27" colour LED monitor, keyboard, mouse,KVM switch, software, SCADA, GUI, OS, Antivirus etc. complete as per specifications and tender document. (Locations: 1 no. in Control room) Note: 1. CPU of control room shall be kept in Panel room in 42 U Rack. KVM extender & reciever is to be supplied at no additional cost 2. TTES Work station at control room shall have provision to connect to 2 nos. of UHD LED monitors . Required hardware & software is to be provided for the same. This is to be provided meeting the tender requirement at no additional cost to IOCL

-

-

-

... More
Open path type Infrared detector (0-150m) along with alignment telescope, configuration & Testing kit etc (Tentative location: TLF Pump House and manifold - 3nos. ,TW pump house and manifold- 3 nos )

6

4661939

-

... More
Supply of Flameproof cum weather proof (IP 66 or better) min SIL 2 certified Hydrocarbon vapour detectors along with test filter,calibration kit, accessories and structural supports, canopy/sunshade etc as per specification and tender document.

-

-

-

... More
Installation of 42 U Rack Enclosure cabinet/System cabinet with 19" rack size, along with accessories like limit switches, earthing arrangements, breaker, SPD type 1+2, fuses, LIU, terminal blocks and wiring etc complete as per specification and tender document for mounting of below mentioned equipments. For mounting of IP PABX equipments along with associated rack type monitor & keyboard, mouse, 4 port industrial grade KVM switches, power adapters, networking & OFC components, Ethernet switch, GSM modems, MCBs etc as per specification and tender documents.

1

17466

-

... More
TANK LORRY FILLING

-

-

-

... More
Supply of 6 core single mode armoured optical fibre cable as per tender specifications and instructions of Engineer in charge.

30000

3150600

-

... More
Installation, integration, configuration, testing and commissioning of industrial type interface module for integration of analogue and IP-devices for IPN systems complete as per specification and tender documents.

1

16764

-

... More
Foam Mother tanks

2

8621

-

3

24263

-

... More
Installation, integration, configuration, testing and commissioning of 25W weather proof Horn type Speaker and mounting accessories etc complete as per specifications and Tender Document. Type : Pole Mountable, suitable for speech and music reproduction Rated power : 25 W Frequency range : 20 Hz TO 20 KHz Ingress protection : Min. IP 65, Standard : EN 60065

7

18808

-

... More
19" Rack mounted at Control Room, Form factor - Rack , Max. 2U height

1

287418

-

... More
Installation, integration, testing and commissioning of parallel redundant UPS of minimum capacity of 60 KVA or as per load calculation (whichever is higher) for entire TAS equipments and third party devices integrated with TAS and powered through TAS UPS with 30% spare capacity for future load connection. The scope also includes supply of parallel battery bank (2x50%) for minimum back up time of ½ hour at full load (rated capacity) along with stand, supports for mounting of the UPS and batteries etc complete as per specification and tender document.

1

21661

-

... More
Supply of flameproof cum weather proof, min SIL 2 certified smart pressure transmitter with display unit & keypad, SS manifold, 1 no. SS isolation ball valve etc on the TLF metering skid complete as per specifications and tender document. (Transmitter will have IEC/ATEX certified minimum along with any other certification as stated else where in tender) (Range 0-15 kg/cm2)

18

862981

-

... More
Treater water Tank + Service water (5)

6

25863

-

... More
RON Additive

2

805456

-

... More
Installation, configuration, integration, testing and commissioning of CCTV client work station along with client software & licenses, key board, mouse, hardware & connector for repeat/ Dual display on wall mounted LED screen, OS, Antivirus, etc complete as per specifications and Tender Document. Note: CCTV Work station shall have provision to connect to 2 nos. of UHD LED monitors . Required hardware & software is to be provided for the same. Incase the offered work station do not have such provision, then additional work station to be provided meeting the tender requirement at no additional cost to IOCL.Marketing CPU for control room & security room shall be kept in Panel room in 42 U Rack. KVM extender & reciever for these CPU is to be supplied at no additional cost.

-

-

-

6

2854245

-

... More
Installation, testing and commissioning of Exd/FLP Emergency Stop push button stations, mushroom head type with protection cover to avoid accidental activation along with mounting structure, accessories etc complete as per specification and tender document.

1

2433

-

... More
Installation, integration, configuration, testing and commissioning of Digital Rodent Repellent System along with mounting accessories for main controller(s) & transducers etc complete as per specification and tender document (Minimum nos of transducers: Invoice room - 4 nos.)

1

12883

-

... More
Installation, Integration, Configuration, Testing and Commissioning of minimum 24 ports Layer 2 Managed Ethernet Switches (10/100/1000 MBPS) along with SFP, copper, fibre modules, accessories for providing IOCL LAN as per specification and tender document. Note: 1. OFC ports to be provided for connecting interbuilding LANs and the communication is through OFC cable

-

-

-

... More
Tower type in Invoice room (1 no.)

1

251105

-

... More
TLF pump and TW Pump Suction end (3 MS, 3 HSD, 2 SKO in TLF and 3 MS, 3 HSD, 2 SKO,2 Ethanol in TW)

18

862981

-

... More
Supply of Door Frame Metal Detector (Main Gate Security room entry- 1 no, License area entry gate-1 no, TLF entry from TTPA-1 no, License area entry from TTPA-1 no) along with accessories, mounting structure etc complete as per specification and tender document.

2

233842

-

... More
Design & Supply of video wall along with controller & complete accecories , cables etc. for CCTV complete as per specifications and tender document. In security cabin:-viewing window size should be preferably be between min. 150-200 cm2 ( in two pages) for CCTV camera.

2

884643

-

... More
Tank farm

10

246159

-

... More
10 M pole with cantilever arrangement for mounting of 1 fixed camera at 6m, 2 PTZ camera at 10 m and LED flood light at 8m of the pole across perimeter as per tender

30

2105592

-

... More
Rack Type - CPU in panel room with KVM sitch; Keyboard, mouse along with monitor etc. to be installed in main gate security room for visitor pass

1

401335

-

... More
Supply of Client workstation of ACS cum Photopass management with minimum 27" coloured monitor,keyboard, mouse,KVM switch (extender/reciver) for Rack CPU, OS, Antivirus, HD coloured video camera (for taking visitors photograph) etc for ID badging & issuing of Visitor pass/Photo pass at security Room & other etc. complete as per specifications.

-

-

-

... More
Installation, Integration, Testing and Commissioning of Manual Call Point along with accessories, fault isolation module (Inbuilt/ External) and structural supports etc required as per standard design engineering, specification and tender document complete in all respect.

-

-

-

... More
Supply of half man height dual lane Uni-directional turnstile (tripod) with controller along with accessories, mounting structure, pressure sensor etc required as per standard design engineering, specification and tender document complete in all respect. (Location : At main gate security entry -1 SET., main gate security exit - 1 SET)

2

403203

-

... More
Open desk operator consoles for mounting of monitor in single tier , key boards, mouse, accesscories e.g. Telephone,VHF sets, Master control station for PA paging,storage for record keeping etc complete as per specification and tender document. Control room - 5 nos, Main Gate security room- 2 nos, Security room near Invoice Room - 1 no, Invoice room- 1 no Note: 1. Provision of installation of four number monitors and its accessories to be provided on console.

9

1506064

-

... More
IP EPABX system 19" Rackable, with 2xS0/8xUPO/E9 only 4 port licensed)/4xanalog (a/b), Integrated IP Gateway x 8 DSP resources, and provision of 10 Port Voicemail with 320 Mailboxes , 02 Channel BRI, 30 Channel PRI, 04 Channel Analog Trunk 100 IP User License. System should be expandable upto 500 IP Extensions. Voicemail License, Auto attendant License, PC base operator console at reception.

1

1356637

-

... More
Installation, integration, testing and commissioning of Triple Offset Butterfly valve with electrical/electro-hydraulic fail safe actuator for ON-OFF operation along with accessories as per installation drawing etc for line size 100 mm complete as per specifications and tender document.

12

57036

-

... More
Laying, glanding, ferruling, termination of FRLS Armoured Copper Signal cable as per tender specifications.

-

-

-

... More
2P x 1.5 sqmm

3200

117056

-

... More
Installation, testing and integration of RON BOOSTER STATIC MIXER

2

20107

-

... More
Security Block Exit gate - Near Invoice room

1

263777

-

... More
Automatic Fire Detection and Alarm System

-

-

-

... More
Installation, Configuration, Integration, Testing and Commissioning of flameproof cum weather proof to IP 65 or better SIL 2 smart pressure transmitter with in built display, SS manifold, SS isolation valve, SS canopy/sunshade, other erection material etc as per hook up drawing attached else where in tender complete as per specifications and Tender Document. (Transmitter will have IEC/ATEX certified minimum and any other certification as stated else where in tender)

-

-

-

... More
For Additive Tanks

2

575903

-

... More
24C x 1.5 sqmm

4100

203196

-

... More
Installation, Integration, Testing and Commissioning of Exd/FLP Local Push button station cum indication lamp out side tank farm dyke wall for remote opening and closing of valves from LPBS along with FLP double compression gland, TBs, mounting structure, accessories etc complete as per specifications and tender document.

-

-

-

... More
Supply of heavy duty high speed laser printer and accessories for invoice printing in invoice room, complete as per specifications and tender document.

2

436951

-

... More
Laying, glanding, ferruling, termination of FS Armoured Copper Signal cable as per tender specifications.

-

-

-

... More
Installation, integration, configuration, testing and commissioning of outdoor Explosion proof cum weatherproof housing (IP 65 or better) suitable for installing Layer 2 switch, PSU, LIU and adaptor for Ethernet switch/media convertor surge protectors and other accessories of PA Paging. The scope also includes supply of Exd. Blinding plugs, LIU, OFC accessories, Exd. double compression cable glands etc. as per specification & tender documents.

16

98308

-

... More
TLF gantry

2

24506

-

... More
19" Rack mounted at Control Room, Form factor - Rack , Max. 2U height

1

443823

-

... More
Supply of industrial type interface module for integration of analogue and IP-devices for IPN systems complete as per specification and tender documents.

1

125491

-

... More
Supply of 42 U Rack Enclosure cabinet/System cabinet with 19" rack size, along with accessories like limit switches, earthing arrangements, breaker, SPD type 1+2, fuses, LIU, terminal blocks and wiring etc complete as per specification and tender document for mounting of below mentioned equipments. For mounting of IP PABX equipments along with associated rack type monitor & keyboard, mouse, 4 port industrial grade KVM switches, power adapters, networking & OFC components, Ethernet switch, GSM modems, MCBs etc as per specification and tender documents.

1

163570

-

... More
Installation, integration, configuration, testing and commissioning of 4 port industrial grade layer 2 Managed POE based Ethernet Switch with 4 Nos. RJ copper port & 2 Nos. optical fiber ports with inbuilt/external surge protector Type (1+2) at the input power supply as per specification and tender documents.

23

139716

-

... More
Product pump addition

1

106410

-

... More
At Invoice room- copper ports of 10/100/1000 MBPS [control LAN - 2 nos. & Management LAN - 2 nos.] ( Minimum 8 nos. copper ports and 2 nos. optical ports)

4

408992

-

... More
Earth Pit

-

-

-

... More
Installation of barrier gate of minimum boom length of 4/5 m along with accessories, controllers etc complete as per specification and tender document for installation at following location. Note: Length of boom barrier mentioned is tentative and boom barrier to be supplied as per length finalized during design Engineering.

-

-

-

... More
4C x 10 sqmm

100

41772

-

... More
24 ways JB

30

132006

-

... More
Installation, integration, configuration, testing and commissioning of 6W weather proof Ring type Speaker and mounting accessories etc complete as per specifications and Tender Document. Type : Indoor, Ceiling Mountable, suitable for speech and music reproduction Rated power : 6W Frequency range : 20 Hz TO 20 KHz Ingress protection : IP 52 Standard : EN 60065

25

46433

-

... More
For Internal Floating Roof Vertical tanks (Primary and Secondary Radar Gauges - )

-

-

-

... More
6C x 1.5 sqmm

1500

60180

-

... More
Control Room equipments

-

-

-

... More
Weather proof Hooter

25

242637

-

... More
Supply of 25W Explosion & weather proof Horn type Speaker and mounting accessories etc complete as per specifications and Tender Document. Type : Pole Mountable, suitable for speech and music reproduction Rated power : 25 W Frequency range : 20 Hz TO 20 KHz Ingress protection : Min. IP 65, FLP Enclosure Required Standard : EN 60065

16

862929

-

... More
Tower mounted type in TM's Cabin (Inbuilt CPU with touchscreen monitor)

1

322674

-

... More
Supply & design of pre-fabricated Metering Skid (MS structure) for mounting of complete metering equipments as per BOQ. The metering assembly comprises of : Main product line: Strainer cum Air eliminator, Spool piece with tapping for additive dosing, MFM, Spool piece with tapping for Temperature Transmitter & pressure Transmitter installation with tapping for connecting outlet of TRV, DCV, Online Master Meter proving manifold, Spool Piece with tapping for Ethanol blending, ON-Off valve & TRV installation. Blend Product line: Strainer cum air eliminator, MFM, Spool piece with tapping for Temperature Transmitter & Pressure Transmitter installation, DCV, Online Master Meter proving manifold, NRV, isolation valve and finally connected to Main stream line tap off point after DCV. Additive Dosing System comprises of isolation valve, Additive injection panel/ block, connecting piping, NRV, isolation valve and finally connecting to Main stream tap off point before MFM. Provision to be made in the skid for mounting of Batch Controller, Rack Monitor, Grounding unit, RIT cum Driver's Ack Push button stations (if applicable), card reader, FLP sockets, FLP junctions boxes (Power, Signal and Control), FLP power isolator switch, interconnecting cables from respective equipment to JBs, cable trays with collar height of 50mm with covers, glands, support, MS structure, nuts, bolts, gaskets, Tees, bends, elbows, WNRF flanges, nozzles, plugs, isolators, any other equipment if required as per design Engineering etc complete as per specification and tender document. Note: Stud Bolts, Blind Flanges (if applicable) Kindly note, irrespective of facility available or not, each metering skid shall have provision for installation of metering assembly of one main product, one blend product and one additive product as detailed in tender document.

24

8388412

-

... More
Supply of Exd/FLP Emergency Stop push button stations, mushroom head type with protection cover to avoid accidental activation along with mounting structure, accessories etc complete as per specification and tender document.

1

7307

-

... More
4C x 6 sqmm

2750

892375

-

... More
Rack type (2 U) (i) with 27" colored LED monitor- Main gate Security Room - 1no.(CPU to be kept in Mkt. panel room),

1

6230

-

... More
Supply of heavy duty SS/brass earthing bolt compatible with offered earthing socket of the grounding unit for mounting on the Tank truck along with accessories like SS nut, lock washer etc complete as per specification and tender document.

1500

1185900

-

... More
At Driver rest room - copper ports of 10/100/1000 MBPS [Management LAN - 2 nos.] (Minimum 4 nos. copper ports and 2 nos. optical ports)

2

6251

-

... More
For Internal Floating Roof Vertical tanks (Primary and Secondary Radar Gauges - )

-

-

-

... More
MS (for line size of 100 mm)

4

4590775

-

... More
Tower Type in Photopass room/Invoice room/Main Gate Security Room for TT crew/Contractor etc.

1

269878

-

... More
18P x 1.5 sqmm

6400

6668416

-

... More
Supply of Operator Interface Console Computer (OIC) minimum 24" colour LED monitor,keyboard, mouse, software, SCADA, GUI, OS, Antivirus, MS office professional etc. complete as per specifications and tender document.

-

-

-

... More
ETHANOL-0.6 KL

1

536721

-

... More
EPABX & TELEPHONE System

-

-

-

... More
At Driver rest room - copper ports of 10/100/1000 MBPS [Management LAN - 2 nos.] (Minimum 4 nos. copper ports and 2 nos. optical ports)

2

204496

-

4

1933184

-

... More
Supply of Terminal servers (rack mounted) with inbuilt/externally mounted lightening and Surge Protection Device Type (1+2) at all Serial ports, for interfacing and integration of field devices (Indoor & outdoor), LED Display unit for TT reporting,at Main Entry gate & Exit gate and TLF Entry gate for Bay allocation with TAS.In case the above listed equipments do not come with open communication protocol compatible to be directly interfaced with DCS Serial / MODBUS TCP IP module complete as per specification and tender document. Note: Terminal Servers to be configured in Dual Redundant mode.

-

-

-

... More
Supply of Open desk operator consoles, chairs, printer tables etc complete as per specification and tender document.

-

-

-

... More
Installation, Configuration, Integration, Testing and Commissioning of Level switch ( Magnetic Float / displacer type ) for low and high level alarm along with mounting accessories etc as per specifications

-

-

-

... More
Installation, Testing and Commissioning of vapour recovery arm of size 80 mm NB having 3” (80 NB) with poppeted vapour coupler, break away coupler, NRV, flame arrestor, reducers, mounting structures, parking stand with compatible API adaptor, associated accessories, mounting structure etc complete as per specifications and tender document. Application : MS

4

36636

-

... More
24 ports - Admin Building (2 Nos)

2

33285

-

... More
Fifth Year @7% of the basic CAPEX cost

1

32981261

-

... More
Supply of Wall mounted/wheel mounted Network Rack-minimum 12U 19" Rack for mounting of Terminal Server/Ethernet switches/LIU/ OFC components along with accessories like power sockets, MCBs, fan, mounting accessories etc complete in all respective at (I) Invoice Room, (ii) Fire Pump house

2

126491

-

... More
Installation, configuration, integration, testing and commissioning of outdoor Explosion proof cum weatherproof housing (IP 65 or better) suitable for installing Layer 2 switch, PSU, LIU and adaptor for Ethernet switch/media convertor, surge protectors and other accessories of CCTV cameras. Supply of required OFC components & accessories like LIU, splice trays, loaded adaptor, blank plates, UTP cables, Fibre patch cords, pigtails, tags, ties, Ethernet cable with RJ45 connector etc complete in all respect for functioning of CCTV camera.The scope also includes supply of Exd. blinding plugs, Exd. double compression cable glands etc as per specifications and Tender Document.

55

244673

-

... More
HSD (for line size of 100 mm )

6

6886163

-

... More
Supply of Complete Terminal Automation Software along with required licences, dongle/keys, GUI, SCADA etc meeting the complete functional and technical requirements of the tender document. Vendor to provide required software, licences, dongle/keys, GUI, SCADA etc for TAS Management Server, Distributed Control System, Operator work stations, fire fighting OIC, Alarm display and annunciation OIC, Engineering Work Stations(for safety PLC & DCS), Web Server, OPC Server, Historian Server / work station, any other devices connected to Control & Management LAN of the integrated Distributed Control System complete as per specification and tender document. TAS software shall be interfaced with following but not limited to major sub-systems / equipments alongwith GUI development for monitoring, logging, reporting, controls & interlocks etc as per specification and tender document. - Safety PLC - TAS- Management Server - TLF Automation System (TT reporting, registration & entry system, TT Queuing, FAN generation, Bay allocation, Additive Dosing system, Ethanol blending System, Interface with TLF equipments like BCU, MFM, Barrier Gates, Bay Queue Display, Bay allocation Display, Invoice generated display, rack monitors, Proximity card readers etc) -Tank Wagon unloading Automation system -Tank Lorry Decantation System - Mobile Application management system - SMS management system - Human/Manpower Tracking Management System

1

3425375

-

... More
Product tank addition

1

123101

-

... More
Supply of 50 mm HDPE pipe of minimum 2.5 mm thick along with accessories as per tender specifications and instructions of Engineer in charge.

500

110330

-

... More
Supply of Tank Truck Entry System (TTES) Workstation with minimum 27" colour LED monitor, keyboard, mouse,KVM switch, software, SCADA, GUI, OS, Antivirus etc. complete as per specifications and tender document. (Locations: 1 no. in Invoice room)

-

-

-

... More
Supply of Retractable Dual Lane Flap barrier with controller along with accessories, mounting structure, pressure sensor etc required as per standard design, engineering, specification and tender document complete in all respect. (Location: Admin building entry/exit )

1

461165

-

... More
Supply of Laser printer (Monochrome) for Visitor pass printing having flexibility to print on A4, A5, A6 paper complete as per specification and tender document. (Location: Main Gate Security Room)

1

44320

-

... More
Supply of Layer 2 Managed Ethernet Switches (10/100/1000 MBPS) along with SFP, copper, fibre modules, accessories for IP PABX network (Non Redundant) complete as per specification and tender document

-

-

-

... More
Design & Supply of video wall along with required controller & complete accecories , cables etc , mounting arrangement from wall/ceiling for fire fighting cum critical Alarm display & annuniciation cum CCTV application complete as per specifications and tender document. In control room:-Windows for all cameras should be available on single screen of 300-400 cm2 for min. 175 nos of CCTV camera. Note: Two Number (min. 55” each or meeting size of video wall) for Alarm LED display and Fire fighting display along with one no. of hooter with provision of dual tone sound,ack push button & accessories.

6

2653930

-

... More
Open path type Infrared detector (0-150m) along with alignment telescope, configuration & Testing kit etc (Tentative location: TLF Pump House and manifold - 3nos. ,TW pump house and manifold- 3 nos )

6

46317

-

... More
Supply of Guided wave RADAR type level gauge with transmitter , instrument accuracy of +/- 3 mm or better, in built digital display, along with mounting accessories etc complete as per specification and tender document. (Transmitter will have IEC/ATEX certified minimum along with any other certification as stated else where in tender) as per specification.

-

-

-

... More
Hydrocarbon Detection system

-

-

-

... More
24C x 1.5 sqmm

100

5546

-

... More
300 mm

1900

1141178

-

... More
Near TT Parking Area ( for TT reporting/registration )

2

8781

-

150

107085

-

... More
Supply of minimum 10 ports ( 8 nos. copper ports of 10/100/1000 MBPS and 2 nos. optical ports) Layer 2 Managed Ethernet Switches along with accessories for connecting the ACS readers installed in Control room,Invoice room as per system architecture and design requirement complete as per specification and tender document. Note: 1. The switches are to be configured in Dual Redundant mode.

2

204496

-

... More
Installation of Wall mounted/wheel mounted Network Rack-minimum 12U 19" Rack for mounting of Terminal Server/Ethernet switches/LIU/ OFC components along with accessories like power sockets, MCBs, fan, mounting accessories etc complete in all respective at (i) Invoice Room, (ii) Fire Pump house

2

9121

-

... More
For product line size 100 mm - TLF

12

1710754

-

... More
For product line size 100 mm - TLF

12

80627

-

... More
For MFM and other serial devices integration to DCS -TLF

4

537164

-

... More
Supply of Digital Rodent Repellent System along with mounting accessories for main controller(s) & transducers etc complete as per specification and tender document (Minimum nos of transducers: Control Room - 12 nos)

1

81083

-

... More
For underground horizontal product tanks

-

-

-

... More
10C x 2.5 sqmm

2650

115699

-

... More
Security Block Entry gate - Near Invoice room

3

58438

-

... More
Across Sludge/Stripping Pumps Strainers---Remote Seal Type

2

8852

-

... More
For U/G horizontal tanks

-

-

-

3

16252

-

... More
Installation, Integration, Testing and Commissioning of parallel redundant Communication Interface Units (CIU) including all accessories etc for tank farm management system complete as per specification and tender document.

-

-

-

... More
Supply of Exd/FLP ESD push button stations, mushroom head type, with protection cover to avoid accidental activation along with mounting structure complete as per specification and tender document.

-

-

-

... More
Pump house

2

49231

-

... More
Jockey Pump Suction and Discharge end

4

191773

-

... More
6C x 1.5 sqmm

4300

172516

-

... More
24C x 1.5 sqmm

4100

2119044

-

... More
Customized Printer Tables of Godrej or equivalent make (2 no. at Main Gate security room for mounting 2 nos. of Photopass printer and 1 visitor pass printer, 2 no. at Invoice room for mouting 2 nos of printer for invoice printing, 2 nos. in control room for two printers, 2nos at security room near Invoice Room for mounting 2 nos of FAN printer ))

8

142695

-

... More
Design, Engineering, Installation, Setup, Configuration, Integration, Testing & Commissioning of Redundant, SIL 3 TUV/ EXIDA certified Safety PLC along with PLC Panels, Marshalling Panels, Biometric fingerprint cum contactless smart card reader with accessories, limit switches, Dual redundant Input Output modules, Power supply units, Relays with base, barriers, TBs, Redundant host communication ports, Serial Interface Modules, any other communication module, HMI, wirings, glands, plugs, other modules/ hardware required for interfacing all the required field and control room equipments including spare requirements, licenses, tags, GUI, licensed OPC compliant software etc complete as per specification and tender document. Note: The offered safety PLC shall be of the same make family of the integrated Distributed Control System.

1

132032

-

... More
Supply of Biometric fingerprint cum contactless type smart card reader along with accessories, software , programming kit etc required as per standard design engineering, specification and tender document complete in all respect. (Turnstile:- Main gate security entry/exit -Dual Lane-Uni directional : 2x2 nos., Pedestrian Entry/Exit Platform to tank farm area (bi-directional)-4x2 nos., Pedestrian entry/exit platform near TLF entry/exit gate (bi-directional)- 2x2 nos., Flap barrier - 2x2nos., Portable reader for visitor pass issuance in Main gate security room- 2 Nos)

22

3262185

-

... More
Installation, Integration, Testing and Commissioning of Density probe along with accessories etc for density measurement of the product complete as per specification and tender document. (Transmitter will have IEC/ATEX certified minimum along with any other certification as stated else where in tender)

-

-

-

... More
For U/G Product tanks (MS- 1 no., HSD - 1 nos., SKO- 1 no., Ethanol -3 nos., RON Additive - 2 nos.)

5

21582

-

... More
Supply of parallel redundant UPS of minimum capacity of 60 KVA or as per load calculation (whichever is higher) for entire TAS equipments and third party devices integrated with TAS and powered through TAS UPS with 30% spare capacity for future load connection. The scope also includes supply of parallel battery bank (2x50%) for minimum back up time of ½ hour at full load (rated capacity) along with stand, supports for mounting of the UPS and batteries etc complete as per specification and tender document.

1

8065906

-

... More
Installation, integration, configuration, testing and commissioning of Standard Table Top Model - Analog Phones with Digital Display

1

875

-

... More
For Additive Tanks

2

10166

-

... More
Design, Installation, Configuration, Testing & Commissioning of Complete Terminal Automation Software along with required licences, dongle/keys, GUI, SCADA etc meeting the complete funtional and technical requirements of the tender document. Vendor to provide required softwares, licences, dongle/keys, GUI, SCADA etc for TAS Management Server, Distributed Control System, Operator work stations, Fire Fighting OIC, Alarm display and annunciation OIC, Engineering Work Stations(for safety PLC & DCS), Web Server, OPC Server, Historian Server / work station, any other devices connected to Control & Management LAN of the integrated Distributed Control System complete as per specification and tender document. TAS software shall be interfaced with following but not limited to major sub-systems / equipments alongwith GUI development for monitoring, logging, reporting, controls & interlocks etc as per specification and tender document. - Safety PLC - TAS Management Server - TLF Automation System (TT reporting, registration & entry system, TT Queuing, FAN generation, Bay allocation, Additive Dosing system, Ethanol blending System, Interface with TLF equipments like BCU, MFM, Barrier Gates, Bay Queue Display, Bay allocation Display, Invoice generated display, rack monitors, Proximity card readers etc) -Tank Wagon unloading Automation system -Tank Lorry Decantation System -Bio Diesel Blending system -Mobile Application Management System -SMS Management System -- Human/Manpower Tracking Management System

1

5748

-

... More
4P x 0.75 sqmm

130

28072

-

... More
At Invoice room- copper ports of 10/100/1000 MBPS [control LAN - 2 nos. & Management LAN - 2 nos.] ( Minimum 8 nos. copper ports and 2 nos. optical ports)

4

12503

-

... More
Installation, integration, testing and commissioning of Monochrome Laser Printer along with accessories for TAS and TFMS report printing in control room (2 nos.) and 2 nos. at security room near Invoice room complete as per specifications and tender document.

4

11733

-

... More
8C x 2.5 sqmm

10500

458430

-

... More
ETHANOL

3

744610

-

50

23128

-

... More
8P x 1.5 sqmm

1400

564984

-

40

57820

-

... More
150 mm

2500

1188850

-

... More
With minimum 8 elements temperature sensor (for above ground tanks - MS, HSD, Ethanol,SKO)

-

-

-

... More
For MOVs in OWS line

26

468146

-

... More
Laying, splicing, ferruling, termination of 6 core single mode armoured optical fibre cable as per tender specifications and instructions of Engineer in charge.

30000

1840800

-

... More
EPABX & TELEPHONE System: Design, detail engineering, supply of equipments/ components of EPABX system along with all necessary accessories.

-

-

-

... More
Push Button station for operation of MOVs in OWS line

-

-

-

... More
Supply of bottom loading arm of size 100 mm NB along with 1 no. full bore isolation ball valve (100 mm), API Coupler, break away coupler, parking stand with compatible API adaptor, Ex-proof/intrinsic safe position sensor for parking stand, TRV with two nos. of isolation valves at inlet and outlet of TRV, associated piping for connecting loading arm with the metering skid & TRV outlet to nozzle before ON-OFF valve, mounting structure etc complete as per specifications and tender document. Application: MS, HSD

10

4185707

-

... More
Installation, integration, testing and commissioning of minimum 10 ports ( 8 nos. copper ports of 10/100/1000 MBPS and 2 nos. optical ports) Layer 2 Managed Ethernet Switches along with accessories for connecting the ACS readers installed in Control room, PMCC, Invoice room, QC lab as per system architecture and design requirement complete as per specification and tender document. Note: 1. The switches are to be configured in Dual Redundant mode.

2

6251

-

... More
3P x 1.5 sqmm

100

4012

-

... More
Installation, Integration, Testing & Commissioning of Ex-proof Rack Monitors for TT overfill protection system along with accessories like 10 pin gantry plug, ATC copper coiled cable of minimum 8m as per API RP1004 including required support for mounting of the Rack Monitor and gantry plug, etc complete as per specifications and tender document. Note: In addition to above, minimum 2 nos. portable Rack Monitor/Tester along with accessories and 2 nos. lockable bypass switch are to be provided against total supply of Rack Monitor.

6

31180

-

... More
Supply of Rj I/O with Voice Tag, Face Plate & Back Box (near each phone)

42

90000

-

... More
Supply of A106 Gr B pipe Dia 25 mm from Blue Dye tank to SKO receipt header line (for dosing purpose) and from SKO receipt header line to Blue dye tank (for dilution & flushing purpose) complete as per specification and tender document. The job includes necessary installation of hardware like reducers, Elbows, equal Tees ,unequal Tees, Flanges, Coupling, Ball Valves for Isolation etc as required complete as per specification and tender document.

1

379709

-

... More
Decantation pump suction and discharge end ( 1 MS, 1 HSD, 1 SKO)

6

18167

-

... More
License area Exit barrier gates ( Near invoice room - 2 no. X 1)

2

8781

-

... More
TLF Header line instruments

-

-

-

... More
Installation, configuration, integration, testing and commissioning of IP Fixed Bullet cameras with MFZ lens (8MP) – 4K resolution along with power supply unit (POE based), with inbuilt/external surge protection unit and mounting accessories etc complete as per specifications and Tender Document.

32

162934

-

... More
Installation, Integration, Testing and Commissioning of additive injection mono block along with accessories for XTRAPREMIUM and XTRAGREEN complete as per specification and tender document. Note - All the wetted parts within Additive injection panel/ block shall be of SS 316 or better.

4

18063

-

... More
Laying ,welding and commissioning of Necessary hardware Like SS Tubing, reducer, Elbows, equal Tee ,unequal tee, Flanges, Coupling, Ball Valve for Isolation, NRV, 15 mm back pressure regulator on return line etc as required for piping and commissioning of the system complete in all respect.

1

61383

-

... More
For Vertical Product tanks

7

1236307

-

25

13216

-

... More
For mounting of Redundant ACS cum photopass management Server along with associated rack mounted monitors, rack mounted keyboard, mouse, 4 port industrial grade KVM switches, power adapters, networking components, MCBs etc as per specification and tender document.

1

147108

-

... More
Installation, testing and commissioning of MCT block for entire Automation cable entry to Control Room, Admin Building, Invoice Room, Security Room, Customer service room, Driver's Rest Room with minimum 30% spare MCT blocks for future cable entry along with frame and mounting accessories complete as per specification and tender document.

1

148022

-

... More
Pump house

2

24506

-

... More
Installation, configuration, testing, integration and Commissioning of Repeater Panel along with software, hardware, mounting accessories etc required as per standard design Engineer, specifications and tender document complete in all respect. (Tentative location : Security Gate - 1 no., Fire Pump House - 1 no.)

2

19920

-

... More
Earth Pit

-

-

-

... More
Laying, glanding, ferruling, termination of FS Armoured Copper Power cable as per tender specifications.

-

-

-

... More
Supply of 42 U Rack Enclosure cabinet/System cabinet with 19" rack size, along with accessories like Biometric fingerprint cum contactless smart card reader for front & back door seperately with accessories, limit switches, earthing arrangements, breaker, fuses, terminal blocks and wiring etc complete as per specification and tender document for mounting of below mentioned equipments.

-

-

-

... More
Sludge/Stripping Pumps suction and discharge end---Remote Seal Type (2 Sludge/Stripping Pumps)

4

191773

-

... More
18C x 1.5 sqmm

7750

420670

-

... More
Supply of Exd/FLP Local Push button station cum indication lamp indicating open, Close, Stop and Ready feebacks near MOVs in OWS line for remote opening and closing of MOVs from LPBS, along with FLP double compression gland, TBs, mounting structure, accessories etc complete as per specifications and tender document.

-

-

-

... More
Supply of Wailing siren along with controller with a provision to operate locally as well as from control room, mounting accessories etc complete as per specification and tender document.

1

75684

-

... More
24C x 1.5 sqmm

100

58764

-

... More
Installation, integration, testing and commissioning of face detection cum fingerprint cum contactless type smart card reader with controller along with electromagnetic door lock of 600 lb for single door/double door, 2 nos. of door position magnetic contact with buzzer etc as per specifications and tender document. (Location : control room first floor main entry/exit door - 2 nos., control room first floor secondary entry/exit door - 2 nos., console room to panel room entry/exit- 2nos, Panel Room exit door - 1no., PMCC first floor- 1 no, Sample room- 1nos, Invoice room-1 no ) Note : 7 nos. electromagnetic door lock to be provided with this item at no additional cost to IOCL.

7

33411

-

... More
TT earthing

4

49012

-

... More
100 mm

6000

2393040

-

... More
Supply of Digital Rodent Repellent System along with mounting accessories for main controller(s) & transducers etc complete as per specification and tender document (Minimum nos of transducers: Invoice room - 4 nos.)

1

59521

-

... More
laying ,welding & commissioning of A106 Gr B pipe Dia 25 mm from Blue Dye tank to SKO receipt header line (for dosing purpose) and from SKO receipt header line to Blue dye tank (for dilution & flushing purpose) complete as per specification and tender document. The job includes necessary installation of hardware like reducers, Elbows, equal Tees ,unequal Tees, Flanges, Coupling, Ball Valves for Isolation etc as required complete as per specification and tender document.

1

50074

-

... More
16C x 1.5 sqmm

18100

5788018

-

... More
For U/G Product tanks (MS- 0 no., HSD - 0 nos., SKO - 0 no, Ethanol -3 nos., RON additive-2 Nos)

5

265977

-

... More
Supply of weather proof two/three line coloured LED display board with scroll and flash effects (Each line of min. 25 mm Character height x 11 characters per line) for outdoor application near Security Gate/ TT parking Area and license area Entry barrier Gate along with mounting structure, canopy/ sunshade, accessories etc complete as per specifications and tender document for displaying the TT Registration no. in bilingual (English + local language) of reported TT whose proximity card has been shown on the PCR adjacent to the display board for TT reporting at security gate/TT parking area, TT status at Security entry gate and the bay no. (Bilingual) etc of the authorised TT reported at license area Entry Gate as per FDR. 2 nos. for TT reporting + 1 no at TTPA Entry+ 1 no at TTPA exit+ 2*2 nos. at License area entry gate+ 2 nos. at License area exit gate+ 2 nos at Security Block Entry/Exit (Near Invoice room) ; Total - 2+1+1+4+2+2=12 Note : 1 line for display in English & 2 lines for displaying in local language

12

2833812

-

... More
8 ways JB

50

144904

-

... More
2C x 1.5 sqmm

8600

304440

-

... More
10 M pole with cantilever arrangement for mounting of 1 fixed camera at 6m, 2 PTZ camera at 10 m and LED flood light at 8m of the pole across perimeter as per tender

30

557089

-

... More
Installation, integration, configuration, testing and commissioning of IP Fixed Bullet cameras with IR MFZ lens (8MP) – 4K resolution along with power supply unit (POE based), with inbuilt/external surge protection unit and mounting accessories etc complete as per specifications and Tender Document.(TT Reporting at TTPA-2+TTEntry -2+Driver Entry-2+Helper Entry-2+TT Exit+ Driver Exit-1+ Driver Exit-2+Photo Pass issuance:- 2)

10

95910

-

... More
Supply of Redundant SIL 3 TUV/ EXIDA certified Safety PLC along with PLC Panels, Marshalling Panels, Biometric fingerprint cum contactless smart card reader with accessories, limit switches, Dual redundant Input Output modules, Power supply units, Relays with base, barriers, TBs, Dual Ethernet ports per processor, Serial Interface Modules, HMI , wirings, glands, plugs, other modules/ hardware required for interfacing all the required field and control room equipments including spare requirements, licenses, tags, GUI, licensed OPC compliant software etc complete as per specification and tender document. Note: The offered safety PLC shall be of the same make family of the integrated Distributed Control System.

1

19889268

-

... More
Supply of ADDITIVE BLOCK ASSEMBLY FOR RON BOOSTER complete as per specification and tender document. Note - All the wetted parts within Additive injection panel/ block shall be of SS 316 or better.

2

686184

-

... More
Main Gate Entry (For Vehicles other than TT)

1

19479

-

... More
For mounting of Rack mounted CPUs of Control room console workstation (Rack type) , one number 19" rack mounted monitor, rack mounted keyboard, mouse, KVM switches for connection of all CPUs along with power adaptors, MCBs, required accessories etc as per specification and tender document.

2

12843

-

... More
Additive dosing System

-

-

-

... More
For Water Tanks

2

595546

-

... More
12C x 1.5 sqmm

3350

1150323

-

... More
Installation of Wall mounted Network Rack-minimum 12U ,19" Network Rack of suitable sizes for mounting of Ethernet switches along with accessories like power sockets, MCBs, fan, LIU, Patch Panel, OFC components ,mounting accessories etc complete in all respective at various Buildings of IP PABX network. (Admin Building - 2 Nos, Control Room -1 No)

5

37081

-

... More
Installation, Integration, Testing and Commissioning of Strainer cum Air eliminator with differential pressure transmitter across the Strainer along with accessories, SS tubing, needle valves etc complete as per specifications and tender document.

-

-

-

... More
Installation, Integration, Testing and Commissioning of Hooter along with accessories, fault isolation module (inbuilt/ External), structural supports etc required as per standard design engineering, specification and tender document complete in all respect.

-

-

-

... More
Rack type (2 U) (i) without colored LED monitor - Control Room - 1 no. ,

1

348266

-

... More
Installation, Integration, Testing and Commissioning of Response Indicator along with accessories, mounting structure etc required as per standard design engineering, specification and tender document complete in all respect. The same to be connected with individual detector installed at places where they are not easily visible e.g. above false ceiling or below false flooring, to give repeat indication of the state of that particular detector.

75

130449

-

50

54162

-

... More
Supply of Standard Table Top Model - Analog Phones with Digital Display

1

2239

-

... More
Installation, integration, configuration, testing and commissioning of IP based Desktop phone Min 3" monochrome display, sensitive soft keys with LED, 3 audio keys (Mute/Speaker/Headset) with LED, 16 free programmable feature keys with LED, IEEE 802.3af PoE, Class 2, 10/100/1000 Base T.

1

3481

-

... More
At Admin Building for TM cabin - copper ports of 10/100/1000 MBPS [control LAN - 2 nos., Management LAN - 2 nos., CCTV - 2 no.] (Minimum 8 nos. copper ports and 2 nos. optical ports) Note: Suitable no. of wireless Access Points to be provided for having wireless connectivity in whole admin building at no additional cost to IOCL..

6

613489

-

... More
Installation, Integration, Testing and Commissioning of Exd/FLP Local Push button station cum indication lamp indicating open, Close, Stop and Ready feebacks near MOVs in OWS line for remote opening and closing of MOVs from LPBS, along with FLP double compression gland, TBs, mounting structure, accessories etc complete as per specifications and tender document.

-

-

-

... More
Installation, Testing and Commissioning of Maintenance Free CPRI approved Earth pit ( Ashlok /Equivalent make ) with 80 mm dia of minimum 3m length safe earthing electrode with Pipe-in-pipe technology consisting of two mild steel pipes one inside the other, hot dip galvanized (80-100 microns), filled with high conductive & corrosion resistance crystalline mixture and backfilling compound around electrode, brick masonry earth pit including plastering in CM 1:4, 600x600 mm C.I. Manhole chamber including providing suitable earth bus for interconnection etc. Equivalent make shall be approved by client / consultants. Procedure recommended by chemical earth supplier and IS code to be finally adopted. Item also includes provision of earth station flags with pit nos. and date of inspection and the next due date of inspection. Job also includes provision of test certificate of earthing station from a class A licensed electrical contractor as per the format of the Corporation. All Instruments, JBs, Equipments in Field and CCR shall be earthed by 6 mm2 PVC insulated copper cable to nearest Insulated copper Earth Bus bar ( minimum size 25 mm x 6 mm ) and this earth bar shall be connected to earth pit by redundant Multi stranded copper cable (Min 25 mm2 ). Signal and Power earth shall be separate as per specification)

-

-

-

... More
Supply of Microprocessor based Coriolis mass flow meter for white oil (Ethanol) application alongwith display unit and mounting accessories with adjustable screw support, reducer (if required) etc for line size 2" suitable for maximum flowrate of 500 LPM complete as per specifications and tender document for ethanol blending. Note: In case MFM is not having inbuilt ASTM table, vendor has to supply Flow Computers along with accessories as per tender document at no adddtional cost to IOCL .

4

2682357

-

... More
Installation, integration, configuration, testing and commissioning of IP System Configuration, Monitoring, Controlling & Reporting Software with client licenses. Scope also include the IP recording system for PA system with licenses with software and accessories.

1

63291

-

... More
TT earthing

4

98463

-

... More
For U/G Tanks with 1 elements

-

-

-

... More
Underground Tanks Discharge Header (1 MS, 1 HSD, 1 SKO, 3 Ethanol)

6

287660

-

... More
12 M pole with cantilever arrangement

1

99279

-

... More
Fire water Sump

1

4310

-

... More
Design & Supply of video wall along with controller & complete accecories , cables etc. for CCTV complete as per specifications and tender document. In location in charge room:-viewing window size should be preferably be between 250-300 cm2 (in two pages) for CCTV camera.

2

884643

-

... More
Make up water Pump Suction and Discharge end

2

6055

-

... More
Local ESD Push Button Station ( Each Battery of TLF -1X1 no., TLF pump house - 1 no., TW Pump House - 1 no., Tank Wagon Area - 13 no.)

16

41970

-

... More
4C x 4 sqmm

4000

151040

-

... More
Providing training to IOCL employee as per schedule/Module for 2 days as per tender document

1

202768

-

... More
1T x 1.5 sqmm

5000

177000

-

... More
Across Strainers in Decantation Pumps ( 1 MS, 1 HSD, 1 SKO)

3

182079

-

... More
32C x 1.5 sqmm

2600

1644448

-

... More
ETHANOL

3

19257

-

... More
The metering assembly comprises of Strainer cum Air eliminator, MFM, Spool piece with tapping for Temperature Transmitter & pressure Transmitter installation, DCV, Online Master Meter proving manifold. Provision to be made in the skid for mounting of Batch Controller,Grounding unit, RIT cum Driver's Ack Push button stations, card reader, FLP sockets, FLP junctions boxes (Power, Signal and Control), FLP power isolator switch, interconnecting cables from respective equipment to JBs, cable trays with collar height of 50mm with covers, glands, support, MS structure, nuts, bolts, gaskets, Tees, bends, elbows, WNRF flanges, nozzles, plugs, isolators, any other equipment if required as per design Engineering etc complete as per specification and tender document. Note: Stud Bolts, Blind Flanges (if applicable)

-

-

-

... More
Installation, Integration, Testing and Commissioning of minimum SIL 2 certified Non - contact type Radar level gauges with instrument accuracy of +/- 1 mm or better along with mounting accessories etc complete as per specification and tender document. (Transmitter will have IEC/ATEX certified minimum along with any other certification as stated else where in tender)

-

-

-

... More
Chairs (Godrej interio Ace Mid back high performance chair)

4

69530

-

... More
Supply of Operator Interface Console Computer (OIC) with 32" colour LED touchscreen monitor, wireless keyboard and mouse for mounting of the same in OIC console, KVM Switch, software, SCADA, GUI, OS, Antivirus, MS office professional etc. complete as per specifications and tender document. CPU shall be kept in Panel room in 42 U Rack. Note: 1. CPU of control room shall be kept in Panel room in 42 U Rack. KVM extender & reciever is to be supplied at no additional cost 2. Connectivity of all the system / CPU to these monitors will be there all the time. At any point of time four system/CPU's display will be available on these monitors. Provision of displaying any system/CPU on any monitors are to be provided to below mentioned CPU/system thru keyboard assign keys or thru seperate hardware . If any seperate hardware is required for the achieving the functionality,same need to be provided at no additioanl cost to IOCL. 3. Panel Mounted System/CPU to be connected to the 4 monitors - 3 nos. OICs , 1 no. Fire fighting OIC , 1 no. TTES , 1 no. TFMS workstation , 1 no. CCTV client ,1 no. EWS ,1 no. Web server etc.

-

-

-

... More
Installation, integration, configuration, testing and commissioning of Ex-proof and weather proof Hooter cum Beacons along with accessories, mounting structure etc complete as per specification and tender document for audio visual alarm at field in case the MOVs installed at tank dyke drain and tank water draw off line is not fully closed. (Tentative location : Each product tank (MS)-3 No., (HSD) - 2 No. (SKO) -2 No., Pump House (TLF and TW) - 2 No.,ETP-1 No.,VRU-1 No.) Location : Near each tank dyke and to be installed outside dyke.

11

42639

-

... More
Installation, integration, configuration, testing and commissioning of Advanced Analytics Software for all fixed cameras (including varifocal, MFZ fixed cameras), Auto tracking video analytics for all PTZ camera along with compatible Redundant Analytics Server with OS, Antivirus etc including analytic license for actual number of camera installed + 20 % spare complete as per specifications and Tender Document.

1

52252

-

... More
Across TLF and TW pump Strainers

18

79671

-

... More
Supply of Multistage Piston type Digital Control Valve (DCV) with secure locking arrangement of the needle valves to avoid manual throttling of the needle valves after final tuning of the DCV has been done, secure key etc along with accessories complete as per specifications and tender document.

-

-

-

... More
Installation, Integration, Testing and Commissioning of Exd/FLP ESD push button stations, mushroom head type, with protection cover to avoid accidental activation along with mounting structure complete as per specification and tender document.

-

-

-

... More
Installation, integration, testing and commissioning of UPS Power Distribution Panel along with Biometric fingerprint cum contactless smart card reader for front and rear gate sepearately with accessories for powering DCS Panel, Safety PLC Panel, TAS-MS, OIC, EWS, TFMS System, TTES, printers, Bay Instruments other control room equipments, Tank Farm Instruments, CCTV system, Fire Detection System, Access control system, Bay Queue Display boards, other display boards, ROSOV ESD port, header line instruments and any other TAS equipments where UPS power are required for smooth un-interrupted operation. Miscellaneous Instrumentation comprising of suitable MCCBs for Isolation, MCB etc are to be provided. The panel shall be complete in all respects with necessary indication lamps for powering, necessary control wiring with digital voltmeter & digital ammeter separately for UPS and Auxilliary supply for front and rear seperately etc as per specifications and tender document. Note: Minimum 20% spare power points to be made available for future use.

1

18386

-

... More
Installation, integration, configuration, testing and commissioning of Layer 3 Managed Gigabit Ethernet Switch with minimum 24 ports or as per site requirement + 20 % spare whichever is higher along with SFP, copper, fibre modules, accessories complete as per specifications and Tender Document. Note- The switches are required to be configured in dual redundant mode

2

6251

-

... More
BLUE DYE DOSING SYSTEM

-

-

-

... More
4C x 2.5 sqmm

1400

247800

-

... More
ETHANOL

3

16252

-

... More
For Secondary Radar Gauges installed on A/G product tanks

1

1051564

-

... More
Ex-proof and weather proof MCP

30

297289

-

... More
For A/G Tanks with 3 elements

-

-

-

... More
Rate of Rise Heat Detector

4

5418

-

... More
Installation, Integration, Configuration, Testing and Commissioning of 24 ports Layer 2 Managed Ethernet Switches (10/100/1000 MBPS) along with SFP, copper, fiber modules, accessories for connecting equipments installed in Plant Control LAN like TAS- MS Servers, OICs, TTES, EWS, OPC Servers, Fire fighting OICs, Alarm Display OIC, DCS, Safety PLC, inter connecting building work stations etc as per system architecture and design requirement complete as per specification and tender document. Note: 1. The switches are to be configured in Dual Redundant mode. 2. OFC ports to be provided for connecting interbuilding LANs, and any other equipment which are to be connected to above switch and the communication is through OFC cable. Note: Suitable no. of wireless Access Points to be provided for having wireless connectivity in whole Control Room at no additional cost to IOCL.

2

6251

-

... More
At the inlet of DG set Service tanks

3

7317

-

... More
Supply of multi point temperature averaging sensor with integrated water interface probe (MSTW) along with mounting accessories etc complete as per specification and tender document.

-

-

-

... More
Supply IP System Configuration, Monitoring, Controlling & Reporting Software with client licenses. Scope also include the IP recording system for PA system with licenses with software and accessories.

1

573626

-

... More
32C x 1.5 sqmm

1500

83190

-

... More
Sludge/Stripping Pumps suction and discharge end---Remote Seal Type (2 Sludge/Stripping Pumps)

4

12111

-

... More
Supply of microprocessor based automatic Fire Alarm Panel along with required Software, and hardware like Control module, monitor module, fault isolation module (in built/ External), mounting structure support etc complete as per standard design engineering, specification and tender document. Location : Control Room

1

649197

-

... More
Supply of IP based Desktop phone Min 3" monochrome display, sensitive soft keys with LED, 3 audio keys (Mute/Speaker/Headset) with LED, 16 free programmable feature keys with LED, IEEE 802.3af PoE, Class 2, 10/100/1000 Base T.

1

25806

-

... More
Supply of 42U Rack enclosure cabinet/System cabinet with 19" rack size, along with accessories like limit switches, earthing arrangements, breaker, SPD type 1+2,fuses, LIU, terminal blocks and wiring etc complete as per specification and tender document for mounting of below mentioned equipments. For mounting PA Paging Servers along with associated rack type monitors & keyboard, mouse, 4 port industrial grade KVM switches, power adapters, networking & OFC components, Ethernet switch, GSM modems, MCBs etc. as per specification and tender documents.

1

155066

-

... More
Tower mounted type in TM's Cabin (Inbuilt CPU with touchscreen monitor)

1

4417

-

... More
For MOVs in water draw off line (AG tanks- 7 Nos)

7

143567

-

... More
License area Entry gate

2

38958

-

... More
Supply of flameproof cum weather proof, temperature transmitter along with display unit, RTD, Thermo well, mounting accessories etc complete as per specifications and tender document. (Mounting at each TLF loading point on main product for line size 100 mm)

12

573734

-

... More
TLF gantry

2

49231

-

... More
4C x 1.5 sqmm

3800

139004

-

... More
Installation, configuration, integration, testing and commissioning of Integral Explosion Proof HD IP Fixed Cameras and MFZ lens (2MP) along with power supply unit , with inbuilt/external surge protection unit and mounting accessories etc complete as per specifications and Tender Document.

6

30550

-

... More
8C x 1.5 sqmm

100

4248

-

... More
8T x 1.5 sqmm

2450

2364838

-

... More
Installation, integration, configuration, testing and commissioning of Digital Rodent Repellent System along with mounting accessories for main controller(s) & transducers etc complete as per specification and tender document (Minimum nos of transducers: Main Gate Security Room - 4 nos)

1

12883

-

... More
For product line size 100 mm - TLF

12

4918645

-

... More
Supply of online proving valves manifold comprising of 1no. manual operated DBBV without actuator and 2 nos. of 100 NB, full bore, zero leakage, fire safe ball valves along with associated piping, Tee connection, gaskets, copper jumpers, fasteners, blind flanges at one end of each ball valves, pipe fittings, WNRF flanges etc for each loading point assembly for making arrangement to connect Mobile master meter for proving of TLF MFM complete as per specifications and tender documents.

12

3373478

-

... More
Installation, integration, configuration, testing and commissioning of Digital Rodent Repellent System along with mounting accessories for main controller(s) & transducers etc complete as per specification and tender document (Minimum nos of transducers: Control Room - 12 nos)

1

12883

-

... More
10C x 1.5 sqmm

3400

144432

-

... More
Laying, glanding, ferruling, termination of 1C x 6 Sq. mm FRLS Flexible copper insulated green wire for earthing instruments and junction boxes etc complete as per specification and tender document

30000

1593000

-

... More
Type 1+2 SPD

4

4111

-

... More
Supply of Strainer cum Air eliminator for line size 50 mm with differential pressure transmitter across the Strainer along with accessories, SS tubing, needle valves etc complete as per specifications and tender document.

4

334657

-

... More
Installation of Exd/FLP Junction Box (Power/Control/Signal JB) with IP 65 as per specification suitable for hazardous area of zone 1, group IIA/IIB, T3 or better having CCOE/CMRI approval. It shall be complete in all respect. Accessories like certified double compression cable glands with PVC shrouds & plugs for excess entries, SS 316 engraved tag plate, mounting clamp & SS 316 fasteners. Complete as per specification / tender documents.

-

-

-

... More
10C x 2.5 sqmm

2650

969370

-

... More
1T x 1.5 sqmm

5000

949900

-

... More
Rate of Rise Heat Detector

4

40167

-

... More
Installation, testing and commissioning of external surge & Lightening protection devices of suitable connector and type along with accessories complete as per specification and tender document at following places.

-

-

-

... More
Supply of Ex-proof Rack Monitors for TT overfill protection system along with accessories like 10 pin gantry plug, ATC copper coiled cable of minimum 8m as per API RP1004 including required support for mounting of the Rack Monitor and gantry plug, etc complete as per specifications and tender document. Note: In addition to above, minimum 2 nos. portable Rack Monitor/Tester along with accessories and 2 nos. lockable bypass switch are to be provided against total supply of Rack Monitor.

6

2692375

-

... More
4C x 1.5 sqmm

3800

596372

-

... More
Supply of 1 no. of Redundant TFMS Server (Form Factor:Rack ,Mountable in 19" rack ) along with 1 no. rack type (1U) ,one no. Min. 19" LED monitor with keyboard & mouse , suitable for 19" mounting & 24x7 operation, Licensed OS (latest supported by TFMS software), Licensed Antivirus, Licensed latest MS Office professional, TFMS licensed software from Radar Gauge OEM etc complete as per specification and tender document.

1

1096509

-

... More
Additive point addition

1

135703

-

... More
Laying, glanding, ferruling, termination of FRLS Armoured Copper Control cable as per tender specifications.

-

-

-

... More
Installation, Integration, Testing and Commissioning of addressable type detectors along with accessories, fault isolation module (Inbuilt), structural supports etc required as per standard design engineering, specification and tender document complete in all respect.

-

-

-

... More
Installation and Commissioning of 42 U Rack Enclosure cabinet/System cabinet with 19" rack size, along with accessories like Biometric fingerprint cum contactless smart card reader for front & back door seperately with accessories, limit switches, earthing arrangements, breaker, fuses, terminal blocks and wiring etc complete as per specification and tender document for mounting of below mentioned equipments.

-

-

-

... More
Installation, integration, testing and commissioning of Retractable Dual Lane Flap barrier with controller along with accessories, mounting structure, pressure sensor etc required as per standard design, engineering, specification and tender document complete in all respect. (Location: Admin building entry/exit )

1

11627

-

... More
Supply of Redundant ACS Server for photo pass management & visitor management (19" Rack type at panel Room, form factor - Rack, CPU height - 2U) with minimum 19" colored LED monitor, KVM switch, keyboard, mouse, OS, Antivirus etc located in Control Room complete as per specifications and Tender Document.

1

680262

-

... More
Laying, glanding,crimping with RJ45 connector, ferruling, termination of LAN cabling for IOCL intranet network inside Control Room,Security room, QC lab, Invoice room, Admin Building etc along with LAN face plate. Cabling to be done from all LAN face plate to respective LAN switches is in scope of vendor. Interbuilding connectivity between switches to be done over OFC cables (OFC cable to be paid seperately) and LAN cabling inside building shall be done using CAT 6 cables inside PVC conduits with proper support above false ceiling, below false flooring etc as per requirement. Control Room,Security room, QC lab, Invoice room, Admin Building etc

15

14283

-

... More
Tower type with Monitor :- Mkt. TM room - 1 No.

1

6230

-

... More
ESD PUSH BUTTON STATION

-

-

-

... More
Foam Daughter Tanks for HVLR

4

309509

-

... More
For Internal Floating Roof Vertical tanks (Primary and Secondary Radar Gauges - )

-

-

-

... More
19" Rack type at Control Room, form factor - Rack, CPU height - 2U

1

4226

-

... More
Installation,integration,testing and commissioning of Guided wave RADAR type level gauge with transmitter , instrument accuracy of +/- 3 mm or better, in built digital display, along with mounting accessories etc complete as per specification and tender document. (Transmitter will have IEC/ATEX certified minimum along with any other certification as stated else where in tender) as per specification.

-

-

-

... More
Rack type (2 U) (ii) with 27" colored LED monitor- Main Gate Security Room - 1no.(CPU to be kept in Mkt. panel room),

1

373303

-

... More
8C x 1.5 sqmm

1100

202488

-

... More
Installation, configuration, testing, integration and Commissioning of microprocessor based automatic Fire Alarm Panel along with required Software, and hardware like Control module, monitor module, fault isolation module ( in built/ External), mounting structure support etc complete as per standard design engineering, specification and tender document. Location : Control Room

1

8005

-

... More
Installation, integration, testing and commissioning of weather proof two/three line coloured LED display board with scroll and flash effects (Each line of min. 25 mm Character height x 11 characters per line) for outdoor application near Security Gate/ TT parking Area and license area Entry barrier Gate along with mounting structure, canopy/ sunshade, accessories etc complete as per specifications and tender document for displaying the TT Registration no. in bilingual (English + local language) of reported TT whose proximity card has been shown on the PCR adjacent to the display board for TT reporting at security gate/TT parking area, TT status at Security entry gate and the bay no. (Bilingual) etc of the authorised TT reported at license area Entry Gate as per FDR. 2 nos. for TT reporting + 1 no at TTPA Entry+ 1 no at TTPA exit+ 2*2 nos. at License area entry gate+ 2 nos. at License area exit gate+ 2 nos at Security Block Entry/Exit (Near Invoice room) ; Total - 2+1+1+4+2+2=10 Note : 1 line for display in English & 2 lines for displaying in local language

12

174748

-

... More
Weather proof MCP

25

43483

-

... More
MS, HSD Tanks Sprinkler & Foam Line

20

60557

-

... More
Note: Laying, glanding, ferruling, termination of cables shall be along with accessories like certified double compression cable glands with PVC shrouds, plugs for excess entries, SS 316 engraved tag plate, mounting clamp, SS 316 fasteners, OFC accessories (like 12/24 port LIU, splice trays, loaded adaptor and blank plates, UTP and optical patch cords, pigtails, media converters etc), LAN face plates, conduits, structural steel for mounting of equipments, making RCC trenches with cover wherever required, hume pipes, Aluminium tags, lugs, ferrules, etc

-

-

-

... More
Treater water Tank + Service water (5)

6

311286

-

... More
Open desk operator consoles for mounting of monitor in single tier , key boards, mouse, accesscories e.g. Telephone,VHF sets, Master control station for PA paging,storage for record keeping etc complete as per specification and tender document. Control room - 5 nos, Main Gate security room- 2 nos, Security room near Invoice Room - 1 no, Invoice room- 1 no Note: 1. Provision of installation of four number monitors and its accessories to be provided on console.

9

47099

-

... More
Seventh Year @7% of the basic CAPEX cost

1

32981261

-

... More
8 ports - Invoice room (1 No), Control room (1 No), PMCC (1 No), Main Gate Security room(1 No), Security Room near Invoice Room(1 No)

5

34987

-

... More
RON Additive

2

10834

-

... More
Supply of external surge & Lightening protection devices of suitable connector and type along with accessories complete as per specification and tender document at following places.

-

-

-

... More
Supply of FRLS Armoured Aluminium Power cable as per tender specifications.

-

-

-

... More
Control room

6

147695

-

... More
4/6 M pole with Accessories as per specification of Tender

35

1450043

-

... More
Miscellaneous

-

-

-

... More
16C x 1.5 sqmm

18100

897036

-

... More
Supply of Pre fab CAT 6 Ethernet un-armoured cable as per tender specifications and instructions of Engineer in charge.

-

-

-

... More
Installation, Configuration, Integration, testing and commissioning of Web Server (Rack type mountable in 19" rack ) along with 1 no. rack type (1U) LED monitor of minimum size of 27" suitable for 24x7 operation, standard keyboard, mouse, web application software, SCADA, GUI, OS, Antivirus etc located in panel Room complete as per specifications and Tender Document. Note: CPU of control room shall be kept in Panel room in 42 U Rack. KVM extender & reciever is to be supplied at no additional cost

1

6421

-

... More
Type 1 SPD

10

130449

-

... More
10C x 1.5 sqmm

7400

2226660

-

... More
Point type Infrared detector (Indicative location: Each tank dyke sump pit inside dyke wall MS- 4 nos.,Near ROSOVs of MS - 12 nos., MS & Ethanol pump seal - 9 nos., Sludge Pump Seal - 2 nos., Pump house drain pit (TLF and TW) - 2 no.; Vapour recovery system drain pit - 1 no., OWS/ETP Pit - 1 No.)

31

183924

-

... More
6C x 1.5 sqmm

1500

297360

-

... More
Installation, integration, testing and commissioning of weather proof LED bay queuing display board (Minimum 15 lines x 100 mm Character height x 25 characters per line) for outdoor installation at TT parking area along with structural steel for mounting of the same, canopy/sunshade etc as per specifications and tender document.

1

16725

-

... More
Installation, integration, configuration, testing and commissioning of 6W weather proof Box type Speaker and mounting accessories etc complete as per specifications and Tender Document. Type : Indoor, Wall Mountable, suitable for speech and music reproduction Rated power : 6W Frequency range : 20 Hz TO 20 KHz Ingress protection : IP 52 Standard : EN 60065

1

1588

-

... More
Tank Farm Management System

-

-

-

... More
Installation, integration, configuration, testing and commissioning of Magnetic flow meter of 65 NB along with two no. SS ball valve with associated piping and mounting accessories etc complete as per specification and tender document.

1

5813

-

... More
RON Additive

2

18179

-

... More
Type 1 SPD

10

10277

-

... More
Installation, Integration, Testing and Commissioning of Resistance - Capacitance type Tank Truck grounding unit along with display for resistance, capacitance values and accessories like 3 nos. of heavy duty flexible coiled cables with high quality rugged, heavy duty SS/ brass grounding socket, FLP double compression glands, Ex-Plug, mounting structure etc, complete as per specification and tender documents. (2 nos. of coiled cable with socket for TT earthing relay interlocks and 1 no. for separate earthing of TT)

6

26875

-

... More
Installation, configuration, integration, testing and commissioning of RFID reader for vehicle identification along with canopy and structure for installation of the reader as per specification and tender document (Main Security gate - 1*2 =2)

2

7481

-

... More
1P x 1.5 sqmm

11000

389400

-

... More
Supply of LED monitor of minimum 55" along with required hardware and software for interfacing with TAS, lockable enclosure (wall mounted) for mounting the monitor along with accessories, canopy/ sunshade etc at invoice room for displaying the list of TTs whose invoice has been generated and TT is still inside license area complete in all respect as per tender requirement. Kindly note, no additional payment shall be made for any additional hardware/ software/ cable etc required for integration of the monitor with TAS.

1

293941

-

... More
Plant ESD Push Button Station ( Each battery of TLF - 1X1 No, TLF Pump house- 1 no, TW Pump House - 1 no., TT unloading Area - 1 No, One no per tank dyke (1*3)- 3 No, Gate from Plant to Wagon Area - 1 no. )

8

20985

-

... More
Supply of FRLS Armoured Copper Signal cable as per tender specifications.

-

-

-

... More
16P x 1.5 sqmm

3000

173460

-

... More
3C x 4 sqmm

100

25724

-

... More
12 ways JB

75

1140853

-

... More
License area Entry barrier gates (Entrance to TLF - 2 no. X2)

4

17563

-

4

1933184

-

... More
Installation, Integration, Testing and Commissioning of Microprocessor based Coriolis mass flow meter for white oil/water application along with display unit and mounting accessories with adjustable screw support etc complete as per specifications and tender document for loading of following main products Note: In case MFM is not having inbuilt ASTM table, vendor has to supply Flow Computers along with accessories as per tender document at no additional cost to IOCL.

-

-

-

... More
12 ways JB

75

242490

-

... More
16P x 1.5 sqmm

3000

2739960

-

... More
DISPLAY BOARDS

-

-

-

... More
For Internal Floating Roof Vertical tanks (Primary and Secondary Radar Gauges - )

-

-

-

... More
For ROSOVs (A/G product tank's inlet, outlet and recirculation line ) ( For MS Tanks- 1 additional line for VRU is also there)

24

492229

-

... More
Foam Mother tanks

2

140158

-

... More
36C x 1.5 sqmm

100

7552

-

... More
12C x 2.5 sqmm

3000

1302720

-

3

764640

-

... More
For mounting of TFMS Server along with associated rack mounted monitors, rack mounted keyboard, mouse, power adapters, networking & OFC components, CIUs MCBs etc as per specification and tender document.

1

147108

-

... More
Main Gate Entry/Exit Gate

2

109128

-

... More
Fire Hydrant lines (Fire Hydrant Header-2+Fire Hydrant line-2+Foam Pump-2)

6

18167

-

... More
Complete LAN cabling for IOCL intranet network inside Control Room,Main Gate Security room, Invoice room, Admin Building, Security room near Invoice Room etc along with LAN face plate. Cabling to be done from all LAN face plate to respective LAN switches is in scope of vendor. Scope also includes supply of Supply of required OFC components & accessories like LIU, splice trays, loaded adaptor, blank plates, UTP cables, Fibre patch cords, pigtails, tags, ties, Ethernet cable with RJ45 connector etc complete in all respects. Interbuilding connectivity between switches to be done over OFC cables (OFC cable to be paid seperately) and LAN cabling inside building shall be done using CAT 6 cables inside PVC conduits with proper support above false ceiling, below false flooring etc as per requirement. Control Room,Main Gate Security room, Invoice room, Admin Building, Security room near Invoice Room etc.

15

188133

-

... More
For U/G horizontal tanks

-

-

-

... More
Installation, Integration, Testing and Commissioning of Tank Truck Entry System (TTES) Workstation with minimum 27" colour LED monitor, keyboard, mouse,KVM switch, software, SCADA, GUI, OS, Antivirus etc. complete as per specifications and tender document. (Locations: 1 no. in Invoice room)

-

-

-

... More
18C x 1.5 sqmm

250

101185

-

... More
Fire Hydrant lines (Fire Hydrant Header-2+Fire Hydrant line-2+Foam Pump-2)

6

287660

-

... More
8 M pole with cantilever arrangement for mounting of 1 fixed camera at 6m and LED flood light at 8m of the pole across perimeter as per tender

35

636515

-

... More
3C x 1.5 sqmm

100

3540

-

... More
Supply of 350 W LED flood ONLY light luminaries on Light poles up to 10M height including supply & fixing of clamps, scafolding , temporary fire screen ifrequired, supports, nuts,bolts, earthing , required modification infixing arrangement , Supply and welding of mounting structure as persite condition , painting etc. all complete with labour and materials asper drawings, specifications and directions of the Engineer-in-Charge.

48

2917356

-

... More
Installation, integration, configuration, testing and commissioning of reduntant server (Rack type) computer with 19" rack mounted Rack type monitor, with keyboard drawer, optical mouse, OS, Antivirus, etc. complete as per specification and tender documents.

1

129128

-

... More
Supply of TFMS Workstation with minimum 27" LED colour monitor, keyboard, mouse, KVM Switch, Licensed OS (latest supported by TFMS software), Licensed Antivirus, Licensed latest MS Office professional, TFMS licensed client software from same Radar Gauge OEM etc complete as per specification and tender document. Note: CPU shall be kept in Panel room in 42 U Rack. KVM extender & reciever is to be supplied at no additional cost.

-

-

-

... More
For mounting of TAS Management Servers along with associated rack mounted monitors, rack mounted keyboard, mouse, 4 port industrial grade KVM switches, power adapters, networking & OFC components, Ethernet switch, GSM modems, MCBs etc as per specification and tender document.

1

147108

-

... More
TTPA Entry gate

1

263777

-

... More
ETHANOL

3

1208184

-

... More
Supply of IP Fixed Box cameras with varifocal lens (8MP) – 4K resolution along with power supply unit (POE based), with inbuilt/external surge protection unit and mounting accessories etc complete as per specifications and Tender Document.

48

4853255

-

... More
Installation, Configuration, Integration, Testing and Commissioning of Operator Interface Console Computer (OIC) with 32" colour LED touchscreen monitor, wireless keyboard and mouse for mounting of the same in OIC console, software, SCADA, GUI, OS, Antivirus, MS office professional etc. complete as per specifications and tender document. Note: 1. CPU of control room shall be kept in Panel room in 42 U Rack. KVM extender & reciever is to be supplied at no additional cost 2. Connectivity of all the system / CPU to these monitors will be there all the time. At any point of time four system/CPU's display will be available on these monitors. Provision of displaying any system/CPU on any monitors are to be provided to below mentioned CPU/system thru keyboard assign keys or thru seperate hardware . If any seperate hardware is required for the achieving the functionality,same need to be provided at no additioanl cost to IOCL. 3. Panel Mounted System/CPU to be connected to the 4 monitors - 3 nos. OICs , 1 no. Fire fighting OIC , 1 no. TTES , 1 no. TFMS workstation , 1 no. CCTV client ,1 no. EWS ,1 no. Web server etc.

-

-

-

... More
Control room

6

73518

-

... More
Sludge tank(1 no.)

1

8087

-

... More
4C x 10 sqmm

100

5074

-

... More
For underground horizontal product tanks

-

-

-

... More
HSD - 1.6 KL

1

7739

-

... More
Supply of flameproof cum weather proof, Temperature transmitter along with display unit, RTD, Thermowell for line size 100 mm, mounting accessories etc complete as per specifications and tender document.

4

175857

-

... More
3C x 2.5 sqmm

100

3540

-

... More
DG Set Service Tanks

3

12931

-

... More
Supply of Microprocessor based Coriolis mass flow meter for white oil/water application along with display unit and mounting accessories with adjustable screw support etc complete as per specifications and tender document for loading of following main products Note: In case MFM is not having inbuilt ASTM table, vendor has to supply Flow Computers along with accessories as per tender document at no additional cost to IOCL.

-

-

-

... More
4C x 2.5 sqmm

5500

3102220

-

... More
Main Gate Entry/Exit Gate

2

8781

-

... More
TTPA Exit gate

1

263777

-

... More
For Vertical Product tanks - (Primary & Secondary Radar Gauges)

14

55771

-

... More
Security Block Entry gate - Near Invoice room

1

263777

-

... More
Laying of 50 mm HDPE pipe of minimum 2.5 mm thick along with accessories as per tender specifications and instructions of Engineer in charge.

500

102660

-

... More
Supply of Monochrome Laser Printer along with accessories for TAS and TFMS report printing in control room (2 nos.) and 2 nos. at FAN printing in security room near Invocie Room complete as per specifications and tender document.

4

393685

-

... More
12C x 1.5 sqmm

3350

154167

-

... More
For BCU integration at TLF (copper ports of 10/100/1000 MBPS)-( Minimum 8 nos. copper ports and 2 nos. optical ports)

2

6251

-

... More
Supply of outdoor Explosion proof cum weatherproof housing (IP 65 or better) suitable for installing Layer 2 switch, PSU, LIU and adaptor for Ethernet switch/media convertor, surge protectors and other accessories of CCTV cameras. Supply of required OFC components & accessories like LIU, splice trays, loaded adaptor, blank plates, UTP cables, Fibre patch cords, pigtails, tags, ties, Ethernet cable with RJ45 connector etc complete in all respect for functioning of CCTV camera.The scope also includes supply of Exd. blinding plugs, Exd. double compression cable glands etc as per specifications and Tender Document.

55

2031499

-

... More
laying ,welding & commissioning of ASTM A106 Gr B Schedule 80 pipe of 25 NB from additive header pipe to additive injection panel at TLF bay complete as per tender document..

100

53808

-

... More
For Cone Roof Vertical tanks (Primary and Secondary Radar Gauges )

-

-

-

... More
At Security Room near Invoice Room - copper ports of 10/100/1000 MBPS [Control LAN- 2 Nos ] (Minimum 8 nos. copper ports and 2 nos. optical ports)

2

204496

-

... More
Supply of RON BOOSTER STATIC MIXER complete as per specification and tender document.

2

372138

-

... More
Supply of flameproof cum weather proof, min SIL 2 certified smart pressure transmitter with display unit & keypad, SS manifold, 1 no. SS isolation ball valve, SS canopy/sunshade with mounting accessories etc on the TLF main header line complete as per specifications and tender document. (Transmitter will have IEC /ATEX certified minimum along with any other certification as stated else where in tender) (Range 0-15 kg/cm2) (TLF HEADER- MS, HSD, Ethanol, SKO,Additive header (XG,XP,RON)- 7 Nos)

7

335603

-

... More
Supply of barrier gate of minimum boom length of 4/5 m along with accessories, controllers etc complete as per specification and tender document for installation at following location. Note: Length of boom barrier mentioned is tentative and boom barrier to be supplied as per length finalized during design Engineering.

-

-

-

... More
8P x 1.5 sqmm

1400

59472

-

... More
Services for Safety Instrumented System testing after installation in presence of safety, operation and engg. Team from user. Demonstration of safety system during pre OISD / OISD & statutory audits & there after periodic testing. Complete as per specifications / tender documents.

1

278741

-

... More
Supply of HD IP Fixed Dome camera with IR and MFZ lens (2MP) along with power supply unit (POE based), with inbuilt/external surge protection unit and mounting accessories etc complete as per specifications and Tender Document.

11

750386

-

... More
Installation, Integration, Testing and Commissioning of intrinsically safe / flameproof type proximity card reader along with mounting accessories etc complete as per specifications for authorisation of TT at

-

-

-

... More
Installation, testing and integration of ADDITIVE BLOCK ASSEMBLY FOR RON BOOSTER complete as per specification and tender document. Note - All the wetted parts within Additive injection panel/ block shall be of SS 316 or better.

2

15134

-

... More
Cabling, JB, Earthing

-

-

-

... More
4C x 2.5 sqmm

1400

54516

-

... More
Installation, Integration, Testing and Commissioning of ESD push button stations (for indoor application), mushroom head type with protection cover to avoid accidental activation along with mounting structure complete as per specification and tender document. (control room - 1 no., security room - 1 no., TM's cabin - 1 no.)

3

7869

-

... More
Installation of Wall mounted/wheel mounted Network Rack-minimum 19U 19" Rack for mounting of Terminal Server/Ethernet switches/LIU/ OFC components along with accessories like power sockets, MCBs, fan, mounting accessories etc complete in all respective at (i) Admin Building

1

4560

-

... More
SIL verification / Validation

-

-

-

... More
Installation of Wall mounted/wheel mounted Network Rack-minimum 19U 19" Rack for mounting of Ethernet switches/LIU/ OFC components along with accessories like power sockets, MCBs, fan, mounting accessories etc complete in all respective at (I) Admin Buidling Supply of required OFC components & accessories like LIU, splice trays, loaded adaptor, blank plates, UTP cables, Fibre patch cords, pigtails, tags, ties, Ethernet cable with RJ45 connector etc complete in all respect for functioning of CCTV camera.

2

5581

-

... More
TANK LORRY FILLING

-

-

-

... More
Tank farm (Product Dykes - 8 Nos (4*2) + Fire water tank - 2 Nos (1*2))

10

122531

-

... More
Chairs (Godrej interio Ace Mid back high performance chair)

4

9746

-

... More
Ethanol Dosing System

-

-

-

... More
Underground Tanks Discharge Header (1 MS, 1 HSD, 1 SKO, 3 Ethanol)

6

18167

-

... More
TLF Header line instruments

-

-

-

... More
Supply of CAT 6 Ethernet armoured cable as per tender specifications and instructions of Engineer in charge.

10000

684400

-

... More
Installation, configuration,integration, testing and commissioning of Client workstation of ACS cum Photopass management with minimum 27" coloured monitor,keyboard, mouse,KVM switch for Rack CPU, OS, Antivirus, HD coloured video camera (for taking visitors photograph) etc for ID badging & issuing of Visitor pass/Photo pass at security Room & other etc. complete as per specifications.

-

-

-

... More
6P x 1.5 sqmm

4000

169920

-

... More
Supply of Repeater Panel along with software, hardware, mounting accessories etc required as per standard design Engineer, specifications and tender document complete in all respect. (Tentative location : Security Gate - 1 no., Fire Pump House - 1 no.)

2

580798

-

... More
At Admin Building for TM cabin - copper ports of 10/100/1000 MBPS [control LAN - 2 nos., Management LAN - 2 nos., CCTV - 2 no.] (Minimum 8 nos. copper ports and 2 nos. optical ports) Note: Suitable no. of wireless Access Points to be provided for having wireless connectivity in whole admin building at no additional cost to IOCL..

6

18754

-

... More
Comphrehensive AMC - PART -III

-

-

-

... More
TLF pumps and TW Pump Discharge end (3 MS, 3 HSD, 2 SKO in TLF and 3 MS, 3 HSD, 2 SKO,2 Ethanol in TW)

18

862981

-

... More
Supply of 4 port industrial grade layer 2 Managed POE based Ethernet Switch with 4 Nos. RJ copper port & 2 Nos. optical fiber ports with inbuilt/external surge protector Type (1+2) at the input power supply as per specification and tender documents.

23

1685258

-

... More
Push Buttons Outside Dyke Walls

-

-

-

... More
Jockey Pump Suction and Discharge end

4

12111

-

... More
Supply of Non-contact type Radar level gauges with instrument accuracy of +/-3 mm or better along with mounting accessories etc complete as per specification and tender document. (Transmitter will have IEC/ATEX certified minimum along with any other certification as stated else where in tender)

-

-

-

... More
Submission of detailed system design, Engineering, Documentations etc as per tender document

1

176749

-

... More
Installation, Testing and Commissioning of Bulk Air Eliminator as per product line size and flow requirement (Min. capacity 1.6 KL) including mounting structure, foundation etc complete as per specification and tender document.

-

-

-

... More
Supply of MCT block for entire Automation cable entry to Control Room, Admin Building, Invoice Room, Security Room, PMCC, Driver's Rest Room with minimum 30% spare MCT blocks for future cable entry along with frame and mounting accessories complete as per specification and tender document.

1

788418

-

... More
Miscellaneous

-

-

-

... More
Supply & design of pre-fabricated Metering Skid (MS structure) along with complete metering equipments for metering of the quantity of product unloaded at TT unloading platform.Metering skid along with its equipment shall be suitable to unload a 20 KL TT in approximately 45 minutes. The typical skid given below is for simultaneous unloading of 2 products (i) Full bore, zero leakage, fire safe ball valves (ii) Strainer cum Air eliminator with differential pressure transmitter across the Strainer along with accessories, SS tubing, needle valves etc complete, spool piece with tapping for installation of PT, RTD with TT- 2 No (iii) Microprocessor based Coriolis mass flow meter for white oil/water application along with display unit and mounting accessories with adjustable screw support etc- 2 No (iv) flameproof cum weather proof, min SIL 2 certified smart pressure transmitter with display unit & keypad, SS manifold, 1 no. SS isolation ball valve etc complete- 2 No (iv) flameproof cum weather proof, temperature transmitter along with display unit, RTD, Thermo well, mounting accessories etc complete- 2 No(v) online proving valves manifold comprising of 1 no. manual operated DBBV without actuator and 2 nos., full bore, zero leakage, fire safe ball valves along with associated piping, Tee connection, gaskets, copper jumpers, fasteners, blind flanges at one end of each ball valves, pipe fittings, WNRF flanges etc- 2 No (vi) Resistance - Capacitance type Tank Truck grounding unit along with display for resistance, capacitance values and accessories like 3 nos. of heavy duty flexible coiled cables with high quality rugged, heavy duty SS/ brass crocodile clamps, FLP double compression glands, Ex-Plug, mounting structure etc, complete - 1 No. (Common for the entire Skid) (vii) Ex-proof field mounted Remote Interaction Terminal (RIT) cum Driver Ack Push Button station along with FLP double compression glands and Ex-Proof-plugs, structural supports etc- 1 No. (Common for the entire Skid) (viii) Exd/FLP ESD push button stations, mushroom head type, with protection cover to avoid accidental activation along with mounting structure complete - 1 No. (Common for the enitre Skid), (ix) Microprocessor based Field mounted dual arm Batch Controller with interface to minimum 2 no. of main product in Flameproof and weather proof enclosure along with accessories like double compression glands, Exd Plugs, hoods, structural supports etc complete, (x) Intrinsically safe / flameproof type proximity card reader along with mounting accessories etc complete - 1 No. (Common for the entire Skid) (xi) Multistage Piston type Digital Control Valve (DCV) with secure locking arrangement of the needle valves to avoid manual throttling of the needle valves after final tuning of the DCV has been done, secure key etc along with accessories complete - 2 No (xii) Air eliminator (capacity shall be designed by the vendor) along with level switches and required accessories as per requirement . (xiii) Pump for unloading the TT suitable for Bio-diesel / Ethanol / NMA etc.(xiv) portable type Density probe for density measurement along with its integration with batch controller / DCS complete with accessories Note: Drawing along with foundation design is in scope of the vendor. Vendor need to provide 3D drawing along with stress calculation of skids.

2

12414780

-

... More
Fire water Sump

1

51881

-

... More
Installation, Integration, and Maintenance & Operation of the NMS System covering Network Devices operational in Terminal Automation System. The Offered Network Management Solution (NMS) solution should support at least the following: • All the proposed NMS Components should be from single vendor. • NMS Software should support Graphical view up to port level for the all the devices. Discovery of Network Elements. • Real time Traffic monitoring of Network Links and Devices with Historical reports for various periods. • Management of SNMPv1, SNMPv2, SNMPv3 & MIB etc. • Configuration of thresholds for Generating alarms. • Configuration of alarm actions (visual, audible, email, sms etc.) for each Network element. • Should be able to provide secured windows based consoles / secured web based consoles for accessibility to NMS. • Should have web browser interface with user name and Password Authentication. • Administrator/ Manager should have privilege to create/modify/delete user. • NMS should have support for SNMPv3 & IPv6, including dual-stack IPv4 & IPv6 to provide flexibility in protocol strategy and implementation.

1

70535

-

... More
Note: Supply of cables shall be along with accessories like certified double compression cable glands with PVC shrouds, plugs for excess entries, SS 316 engraved tag plate, mounting clamp, SS 316 fasteners , OFC accessories (like 12/24 port LIU, splice trays, loaded adaptor and blank plates, UTP and optical patch cords, pigtails, media converters etc), LAN face plates, conduits, structural steel for mounting of equipments, making RCC trenches with cover wherever required, hume pipes, Aluminium tags, lugs, ferrules, etc

-

-

-

... More
Supply of 4 port Industrial grade layer 2 Managed POE based Ethernet Switch for connecting Cameras with 4 Nos. RJ copper port and 2 Nos. optical fibre ports with inbuilt/external surge protector (Type 1+2) at the input power supply as per specifications and Tender Document.

55

4093243

-

... More
Laying of anodized Aluminium perforated cable trays (2.5mm Thick and 25mm edge height), tray covers (1.5mm Thick and 10 mm edge height) along with structural steel for mounting of the cable tray. Complete as per specifications / tender documents.

-

-

-

... More
Supply of Turbine Flow Meter (40/50 MM) with pulse transmitter and field totalizer unit in n Flameproof and Weather Proof (Min. IP 65) enclosure along with two number of SS ball valve,strainer cum aireliminter (50 mm) and associated piping as tender specification and mounting accessories complete as per specification and tender document. Note: For HSD Measurement to pipeline division.

2

378721

-

... More
Across Strainers in RON additive pump

2

8852

-

... More
Supply of 4 port Industrial grade layer 2 Managed POE based Ethernet Switch for connecting ACS readers with 4 Nos. RJ copper port and 2 Nos. optical fibre ports with inbuilt/external surge protector (Type 1+2) at the input power supply as per specifications and Tender Document.

10

744226

-

... More
Supply of Advanced Analytics Software for all fixed cameras (including varifocal, MFZ fixed cameras), Auto tracking video analytics for all PTZ camera along with compatible Redundant Analytics Server with OS, Antivirus etc including analytic license for actual number of camera installed + 20 % spare complete as per specifications and Tender Document.

1

1371158

-

... More
U/G Slop Oil

1

5083

-

... More
Across Strainers in Decantation Pumps ( 1 MS, 1 HSD, 1 SKO)

3

13278

-

... More
Installation, integration, configuration, testing and commissioning of IP EPABX system 19" Rackable, with 2xS0/8xUPO/E9 only 4 port licensed)/4xanalog (a/b), Integrated IP Gateway x 8 DSP resources, and provision of 10 Port Voicemail with 320 Mailboxes , 02 Channel BRI, 30 Channel PRI, 04 Channel Analog Trunk 100 IP User License. System should be expandable upto 500 IP Extensions. Voicemail License, Auto attendant License, PC base operator console at reception.

1

240146

-

... More
Installation, integration, configuration, testing and commissioning of Master Control Station for control room at Console Desk: • Modular design providing individual design and configuration of the device • Telephone set module with a handset, build‐in speaker and microphone for duplex twoway communication • Call station module for duplex and simplex communication • Up to 3 extension modules (42‐126 keys) • Hands‐free communication • Gooseneck microphone with optical «on‐off» indication • Easy maintenance and configuration by control keys and display • Volume Setting • Hot swapping • Color TFT display • Button labeling (transparent buttons) • LED indications for incoming, missed call and line status (busy)

1

29378

-

... More
Supply of 2" size SS 304 guiding rail along with mounting accessories complete as per specification and tender document near turnstile/ tripod/flap barrier etc to prevent un-authorised movement.

100

106082

-

... More
Supply of outdoor weatherproof housing (IP 65 or better) suitable for installing Layer 2 switch, PSU, LIU and adaptor for Ethernet switch/media convertor surge protectors and other accessories of PA Paging System. The scope also includes supply of blinding plugs, LIU, OFC accessories, double compression cable glands etc as per specifications and Tender Document.

7

157427

-

... More
24 ports - Admin Building (2 Nos)

2

378147

-

... More
HSD (for line size of 100 mm )

6

32355

-

... More
600 mm

1100

1047486

-

... More
6 ways JB

80

231846

-

... More
18C x 1.5 sqmm

7750

4106105

-

... More
SKO (for line size of 100 mm )

2

10785

-

... More
Installation, Integration, Testing and Commissioning of flameproof cum weather proof, min SIL 2 certified smart pressure transmitter with display unit & keypad, SS manifold, 1 no. SS isolation ball valve, SS canopy/sunshade with mounting accessories etc on the TLF main header line complete as per specifications and tender document. (Transmitter will have IEC /ATEX certified minimum along with any other certification as stated else where in tender) (Range 0-15 kg/cm2) (TLF HEADER- MS, HSD, Ethanol, SKO,Additive header (XG,XP,RON)- 7 Nos)

7

26208

-

... More
Main Gate Exit (For Vehicles other than TT)

1

263777

-

... More
Supply of half man height bi-directional turnstile (tripod) with controller along with accessories, mounting structure, pressure sensor etc required as per standard design engineering, specification and tender document complete in all respect. (Location : Pedestrian Entry/Exit Platform to tank farm area - 4+ Pedestrian entry/exit platform near TLF entry/exit gate (2*1) =2 nos. )

6

1301403

-

2

509760

-

... More
Supply of Digital Rodent Repellent System along with mounting accessories for main controller(s) & transducers etc complete as per specification and tender document (Minimum nos of transducers: Security room near Invoice Room - 4 nos)

1

59521

-

... More
8 ports - Invoice room (1 No), Control room (1 No), PMCC (1 No), Main Gate Security room(1 No), Security Room near Invoice Room(1 No)

5

704218

-

... More
Combination/Multi-sensor Detector

285

2200410

-

... More
Supply of public address system along with accessories like speakers, amplifier, mike complete for announcement in TT Parking area as per specifications and tender document.

1

125186

-

... More
Supply of Response Indicator along with accessories, mounting structure etc required as per standard design engineering, specification and tender document complete in all respect.

75

79738

-

... More
SPD (Type 2 / IC category C1,C2,C3,D1)

30

30833

-

... More
600 mm

1100

3726558

-

... More
1P x 1.5 sqmm

2000

70800

-

... More
At the inlet of Fire Engine Service tanks

2

62785

-

... More
Installation, integration, configuration, testing and commissioning of Intelligent video operation, control, management, recording & processing software (VMS) complete as per specifications and Tender Document with minimum 125 cameras recording, 125 cameras viewing license, 5 LISC licence for remote viewing or as per actual nos. of cameras installed + 20% extra which ever is higher.

1

57333

-

... More
Installation,integration, testing and commissioning of 1 no. of Redundant TFMS Server (Form Factor:Rack ,Mountable in 19" rack ) along with 1 no. rack type (1U) ,one no. Min. 19" LED monitor with keyboard & mouse ,suitable for 19" mounting & 24x7 operation, Licensed OS (latest supported by TFMS software), Licensed Antivirus, Licensed latest MS Office professional, TFMS licensed software from Radar Gauge OEM etc complete as per specification and tender document.

1

4336

-

... More
For Water Tanks (2 nos.), Sludge tank(1 no.)

3

11951

-

... More
24 ports - Admin Building (2 Nos)

2

5581

-

... More
Supply of Maintenance Free CPRI approved Earth pit ( Ashlok /Equivalent make ) with 80 mm dia of minimum 3m length safe earthing electrode with Pipe-in-pipe technology consisting of two mild steel pipes one inside the other, hot dip galvanized (80-100 microns), filled with high conductive & corrosion resistance crystalline mixture and backfilling compound around electrode, brick masonry earth pit including plastering in CM 1:4, 600x600 mm C.I. Manhole chamber including providing suitable earth bus for interconnection etc. Equivalent make shall be approved by client / consultants. Procedure recommended by chemical earth supplier and IS code to be finally adopted. Item also includes provision of earth station flags with pit nos. and date of inspection and the next due date of inspection. Job also includes provision of test certificate of earthing station from a class A licensed electrical contractor as per the format of the Corporation. All Instruments, JBs, Equipments in Field and CCR shall be earthed by 6 mm2 PVC insulated copper cable to nearest Insulated copper Earth Bus bar ( minimum size 25 mm x 6 mm ) and this earth bar shall be connected to earth pit by redundant Multi stranded copper cable (Min 25 mm2 ). Signal and Power earth shall be separate as per specification)

-

-

-

... More
Installation, Integration, Testing and Commissioning of Tank Truck Entry System (TTES) Workstation with minimum 27" colour LED monitor, standard keyboard, mouse, software, SCADA, GUI, OS, Antivirus etc. complete as per specifications and tender document. 1. TTES Work station shall have provision to connect to 2 nos. of UHD LED monitors . Required hardware & software is to be provided for the same. This is to be provided meeting the tender requirement at no additional cost to IOCL

-

-

-

... More
For mounting of TFMS Server along with associated rack mounted monitors, rack mounted keyboard, mouse, power adapters, networking & OFC components, CIUs MCBs etc as per specification and tender document.

1

6266

-

2

509760

-

... More
48C x 1.5 sqmm

8000

556960

-

... More
Installation, integration, testing and commissioning of 4 nos. hand held metal detector along with accessories, mounting structure etc complete as per specification and tender document.

4

2765

-

... More
Supply of GI strip ( 50mm X 6mm) with Hot dip galvanizing (800 gm/m2 as per IS 4759) along with accessories required for complete Terminal Automation System as per Standard Design Engineering, specification and tender document.

10000

2501600

-

... More
Installation, Integration, Testing and Commissioning of Non- Contact type Radar level gauges with instrument accuracy of +/-3 mm or better along with mounting accessories etc complete as per specification and tender document. (Transmitter will have IEC/ATEX certified minimum along with any other certification as stated else where in tender)

-

-

-

... More
8 ports - Invoice room (1 No), Control room (1 No), Main Gate Security room(1 No), Security Room near Invoice Room(1 No)

4

11162

-

... More
32C x 1.5 sqmm

2600

159536

-

... More
Fire Engine Service tanks

2

8621

-

... More
Installation, integration, testing and commissioning of flameproof cum weather proof, min SIL 2 certified smart pressure transmitter with display unit & keypad, SS manifold, 1 no.SS isolation ball valve etc on the TLF metering skid complete as per specifications and tender document. (Transmitter will have IEC/ATEX certified minimum along with any other certification as stated else where in tender) (Range 0-15 kg/cm2)

18

79416

-

... More
For connecting all MODBUS TCP IP devices ( any other devices) to DCS Ethernet port directly for integration (copper ports of 10/100/1000 MBPS)- to be located in Control Room ( Minimum 8 nos. copper ports and 2 nos. optical ports)

2

204496

-

... More
Installation, Integration, Testing and Commissioning of Strainer cum Air eliminator for line size 50 mm with differential pressure transmitter across the Strainer along with accessories, SS tubing, needle valves etc complete as per specifications and tender document.

4

25148

-

... More
For ROSOVs (A/G product tank's inlet, outlet and recirculation line ) ( For MS Tanks- 1 additional line for VRU is also there)

24

62955

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.