Indian Institute Of Science Education And Research Tender

... More
Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.

Indian Institute Of Science Education And Research - IISER Tender

Works
Eprocure
Opening Date5 Aug 2021
Closing Date12 Aug 2021
Tender Amount₹ 1,31,00,000 
Notes
Download

Costs

Summary

Restoration Of Electrical Services At Chemistry Block At Iiser

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supplying LT cable having Aluminium conductor XLPE insulated sheathed,galvanised steel tape armoured cable with pvc outer sheathing 1.1 KV ( Confirming to IS 7098 Part-II amended upto date as per the following sizes). Including the cost of all materials, lobour, Handling of materials of equipment and machineries all lead lift, loading and unloading, transportation, if any other incidental charges at all level complete all as per specification and as directed by Engineer-in charge. 3.5 Core x 185 Sqmm Armoured Aluminium (A2XFY) Cable.

100

-

-

... More
Supplying LT cable having Aluminium conductor XLPE insulated sheathed,galvanised steel tape armoured cable with pvc outer sheathing 1.1 KV ( Confirming to IS 7098 Part-II amended upto date as per the following sizes). Including the cost of all materials, lobour, Handling of materials of equipment and machineries all lead lift, loading and unloading, transportation, if any other incidental charges at all level complete all as per specification and as directed by Engineer-in charge. 3.5 Core x 150 Sqmm Armoured Aluminium (A2XFY) Cable.

400

-

-

... More
Supplying LT cable having Aluminium conductor XLPE insulated sheathed,galvanised steel tape armoured cable with pvc outer sheathing 1.1 KV ( Confirming to IS 7098 Part-II amended upto date as per the following sizes). Including the cost of all materials, lobour, Handling of materials of equipment and machineries all lead lift, loading and unloading, transportation, if any other incidental charges at all level complete all as per specification and as directed by Engineer-in charge. 3.5 Core x 70 Sqmm Armoured Aluminium (A2XFY) Cable.

50

-

-

... More
Supplying LT cable having copper conductor XLPE insulated sheathed,galvanised steel tape armoured cable with pvc outer sheathing 1.1 KV ( Confirming to IS 7098 Part-II amended upto date as per the following sizes). Including the cost of all materials, lobour, Handling of materials of equipment and machineries all lead lift, loading and unloading, transportation, if any other incidental charges at all level complete all as per specification and as directed by Engineer-in charge. 4 Core x 10 Sqmm Armoured Copper Cable.

5000

-

-

... More
Supplying LT cable having copper conductor XLPE insulated sheathed,galvanised steel tape armoured cable with pvc outer sheathing 1.1 KV ( Confirming to IS 7098 Part-II amended upto date as per the following sizes). Including the cost of all materials, lobour, Handling of materials of equipment and machineries all lead lift, loading and unloading, transportation, if any other incidental charges at all level complete all as per specification and as directed by Engineer-in charge. 4 Core X 4 YWY ( Fume hood )

450

-

-

... More
Supplying LT cable having copper conductor XLPE insulated sheathed,galvanised steel tape armoured cable with pvc outer sheathing 1.1 KV ( Confirming to IS 7098 Part-II amended upto date as per the following sizes). Including the cost of all materials, lobour, Handling of materials of equipment and machineries all lead lift, loading and unloading, transportation, if any other incidental charges at all level complete all as per specification and as directed by Engineer-in charge. 4 C X 2.5 YWY ( pump motor )

250

-

-

... More
Supplying LT cable having copper conductor XLPE insulated sheathed,galvanised steel tape armoured cable with pvc outer sheathing 1.1 KV ( Confirming to IS 7098 Part-II amended upto date as per the following sizes). Including the cost of all materials, lobour, Handling of materials of equipment and machineries all lead lift, loading and unloading, transportation, if any other incidental charges at all level complete all as per specification and as directed by Engineer-in charge. 2 C X 1.0 YWY ( VAV & Push button)

200

-

-

... More
Supplying LT cable having copper conductor XLPE insulated sheathed, galvanized steel tape unarmoured cable with pvc outer sheathing 1.1 KV class ( Conforming to IS 7098 Part-II amended upto date as per the following sizes). Including the cost of all materials, lobour , Handling of materials of equipment and machineries all lead lift, loading and unloading, transportation, if any other incidental charges at all level complete all as per specification and as directed by Engineer-in charge. 1 Core x 120 Sqmm FRLS Heavy Duty unarmoured Copper (CuYY) Cable.

150

-

-

... More
Supplying LT cable having copper conductor XLPE insulated sheathed, galvanized steel tape unarmoured cable with pvc outer sheathing 1.1 KV class ( Conforming to IS 7098 Part-II amended upto date as per the following sizes). Including the cost of all materials, lobour , Handling of materials of equipment and machineries all lead lift, loading and unloading, transportation, if any other incidental charges at all level complete all as per specification and as directed by Engineer-in charge. 1 Core x 70 Sqmm FRLS Heavy Duty unarmoured Copper (CuYY) Cable.

100

-

-

... More
Laying of 1 no. of above mentioned XLPE cables of 1.1KV grade direct on existing cable tray ,in trench from ASB1 including tying of cables neatly with nylon tape and labeling etc, as required. Including the cost of all materials, lobour, Handling of materials of equipment and machineries all lead lift, loading and unloading, transportation, if any other incidental charges at all level complete all as per specification and as directed by Engineer-in charge. 3.5 Core x 300 Sqmm Armoured Aluminium (A2XFY) Cable.

350

-

-

... More
Laying of 1 no. of above mentioned XLPE cables of 1.1KV grade direct on existing cable tray ,in trench from ASB1 including tying of cables neatly with nylon tape and labeling etc, as required. Including the cost of all materials, lobour, Handling of materials of equipment and machineries all lead lift, loading and unloading, transportation, if any other incidental charges at all level complete all as per specification and as directed by Engineer-in charge. 3.5 Core x 240 Sqmm Armoured Aluminium (A2XFY) Cable.

450

-

-

... More
Laying of 1 no. of above mentioned XLPE cables of 1.1KV grade direct on existing cable tray ,in trench from ASB1 including tying of cables neatly with nylon tape and labeling etc, as required. Including the cost of all materials, lobour, Handling of materials of equipment and machineries all lead lift, loading and unloading, transportation, if any other incidental charges at all level complete all as per specification and as directed by Engineer-in charge. 3.5 Core x 185 Sqmm Armoured Aluminium (A2XFY) Cable.

100

-

-

... More
Laying of 1 no. of above mentioned XLPE cables of 1.1KV grade direct on existing cable tray ,in trench from ASB1 including tying of cables neatly with nylon tape and labeling etc, as required. Including the cost of all materials, lobour, Handling of materials of equipment and machineries all lead lift, loading and unloading, transportation, if any other incidental charges at all level complete all as per specification and as directed by Engineer-in charge. 3.5 Core x 70 Sqmm Armoured Aluminium (A2XFY) Cable.

50

-

-

... More
Laying of 1 no. of above mentioned XLPE cables of 1.1KV grade direct on existing cable tray ,in trench from ASB1 including tying of cables neatly with nylon tape and labeling etc, as required. Including the cost of all materials, lobour, Handling of materials of equipment and machineries all lead lift, loading and unloading, transportation, if any other incidental charges at all level complete all as per specification and as directed by Engineer-in charge. 4 Core x 10 Sqmm Armoured Copper Cable.

5000

-

-

... More
Laying of 1 no. of above mentioned XLPE cables of 1.1KV grade direct on existing cable tray ,in trench from ASB1 including tying of cables neatly with nylon tape and labeling etc, as required. Including the cost of all materials, lobour, Handling of materials of equipment and machineries all lead lift, loading and unloading, transportation, if any other incidental charges at all level complete all as per specification and as directed by Engineer-in charge. 4 Core X 4 YWY ( Fume hood )

450

-

-

... More
Laying of 1 no. of above mentioned XLPE cables of 1.1KV grade direct on existing cable tray ,in trench from ASB1 including tying of cables neatly with nylon tape and labeling etc, as required. Including the cost of all materials, lobour, Handling of materials of equipment and machineries all lead lift, loading and unloading, transportation, if any other incidental charges at all level complete all as per specification and as directed by Engineer-in charge. 4 C X 2.5 YWY ( pump motor )

250

-

-

... More
Laying of 1 no. of above mentioned XLPE cables of 1.1KV grade direct on existing cable tray ,in trench from ASB1 including tying of cables neatly with nylon tape and labeling etc, as required. Including the cost of all materials, lobour, Handling of materials of equipment and machineries all lead lift, loading and unloading, transportation, if any other incidental charges at all level complete all as per specification and as directed by Engineer-in charge. 2 C X 1.0 YWY ( VAV & Push button)

200

-

-

... More
END TERMINATION: Supply and installation of End termination of cables with compression brass cable glands, Al crimping type lugs should be used for Al cables and Cu lugs with soldering and ferrules for the following 1.1kv class Al./Cu. XLPE/PVC insulated using necessary crimping tool and all other accessories as required and Including the cost of all materials, lobour, Handling of Materials of equipment and machineries all lead lift, loading and unloading, transportation, if any other incidental charges at all level complete all as per specification and as directed by Engineer-in charge. 3.5 Core x 400 Sqmm Armoured Aluminium (A2XFY) Cable.

2

-

-

... More
END TERMINATION: Supply and installation of End termination of cables with compression brass cable glands, Al crimping type lugs should be used for Al cables and Cu lugs with soldering and ferrules for the following 1.1kv class Al./Cu. XLPE/PVC insulated using necessary crimping tool and all other accessories as required and Including the cost of all materials, lobour, Handling of Materials of equipment and machineries all lead lift, loading and unloading, transportation, if any other incidental charges at all level complete all as per specification and as directed by Engineer-in charge. 3.5 Core x 300 Sqmm Armoured Aluminium (A2XFY) Cable.

4

-

-

... More
END TERMINATION: Supply and installation of End termination of cables with compression brass cable glands, Al crimping type lugs should be used for Al cables and Cu lugs with soldering and ferrules for the following 1.1kv class Al./Cu. XLPE/PVC insulated using necessary crimping tool and all other accessories as required and Including the cost of all materials, lobour, Handling of Materials of equipment and machineries all lead lift, loading and unloading, transportation, if any other incidental charges at all level complete all as per specification and as directed by Engineer-in charge. 3.5 Core x 240 Sqmm Armoured Aluminium (A2XFY) Cable.

8

-

-

... More
END TERMINATION: Supply and installation of End termination of cables with compression brass cable glands, Al crimping type lugs should be used for Al cables and Cu lugs with soldering and ferrules for the following 1.1kv class Al./Cu. XLPE/PVC insulated using necessary crimping tool and all other accessories as required and Including the cost of all materials, lobour, Handling of Materials of equipment and machineries all lead lift, loading and unloading, transportation, if any other incidental charges at all level complete all as per specification and as directed by Engineer-in charge. 3.5 Core x 185 Sqmm (A2XFY) XLPE AL. AR. Cable.

4

-

-

... More
END TERMINATION: Supply and installation of End termination of cables with compression brass cable glands, Al crimping type lugs should be used for Al cables and Cu lugs with soldering and ferrules for the following 1.1kv class Al./Cu. XLPE/PVC insulated using necessary crimping tool and all other accessories as required and Including the cost of all materials, lobour, Handling of Materials of equipment and machineries all lead lift, loading and unloading, transportation, if any other incidental charges at all level complete all as per specification and as directed by Engineer-in charge. 3.5 Core x 70 Sqmm (A2XFY) XLPE AL. AR. Cable.

2

-

-

... More
END TERMINATION: Supply and installation of End termination of cables with compression brass cable glands, Al crimping type lugs should be used for Al cables and Cu lugs with soldering and ferrules for the following 1.1kv class Al./Cu. XLPE/PVC insulated using necessary crimping tool and all other accessories as required and Including the cost of all materials, lobour, Handling of Materials of equipment and machineries all lead lift, loading and unloading, transportation, if any other incidental charges at all level complete all as per specification and as directed by Engineer-in charge. 4 Core x 10 Sqmm Armoured Copper Cable.

150

-

-

... More
END TERMINATION: Supply and installation of End termination of cables with compression brass cable glands, Al crimping type lugs should be used for Al cables and Cu lugs with soldering and ferrules for the following 1.1kv class Al./Cu. XLPE/PVC insulated using necessary crimping tool and all other accessories as required and Including the cost of all materials, lobour, Handling of Materials of equipment and machineries all lead lift, loading and unloading, transportation, if any other incidental charges at all level complete all as per specification and as directed by Engineer-in charge. 4 Core X 2.5 YWY Cu Armoured Cable ( pump motor )

8

-

-

... More
END TERMINATION: Supply and installation of End termination of cables with compression brass cable glands, Al crimping type lugs should be used for Al cables and Cu lugs with soldering and ferrules for the following 1.1kv class Al./Cu. XLPE/PVC insulated using necessary crimping tool and all other accessories as required and Including the cost of all materials, lobour, Handling of Materials of equipment and machineries all lead lift, loading and unloading, transportation, if any other incidental charges at all level complete all as per specification and as directed by Engineer-in charge. 2 Core X 1.0 YWY Cu Armoured Cable ( VAV & Push Button )

6

-

-

... More
PERFORATED TYPE CABLE TRAYS : Supplying and installing following size of perforated painted with powder coating M.S. cable trays bends with perforation not more than 17.5%,, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.600 mm Width x 50mm depth x 2mm thick.

50

-

-

... More
PERFORATED TYPE CABLE TRAYS : Supplying and installing following size of perforated painted with powder coating M.S. cable trays bends with perforation not more than 17.5%,, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.450 mm Width x 50mm depth x 2mm thick.

70

-

-

... More
PERFORATED TYPE CABLE TRAYS : Supplying and installing following size of perforated painted with powder coating M.S. cable trays bends with perforation not more than 17.5%,, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.300 mm Width x 50mm depth x 1.6mm thick.

90

-

-

... More
PERFORATED TYPE CABLE TRAYS : Supplying and installing following size of perforated painted with powder coating M.S. cable trays bends with perforation not more than 17.5%,, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.150 mm Width x 50mm depth x 1.6mm thick.

170

-

-

... More
FINAL DISTRIBUTION BOARDS. PART - C - DB's & MCB's : Supply, Installation, Testing and Commissioning of all MCB Distribution Boards (10KA) 415V, made out of 16SWG MS sheet steel enclosure hinged MS cover/over flanged cover (double door) with cutouts for operating the MCB knobs and comprising of phase bus bars, neutrals and earth bus with tapped holes, bakelite phase barriers, pvc insulator shoes for incoming wire, etc complete. DB's shall be mounted by grouting in to the wall/angle to brick wall as required. DB's shall be suitable for Three Phase / single phase loads. Or DB's shall be mounted on suitable M.S. angle and supporting flat. DB's shall include termination lugs etc., all complete. (Note: Local fabrication not permitted. Only factory made boxes shall be installed and all MCB's shall be with 10 KA rating)Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required 8 way (4 + 24), Double door for RPDB

6

-

-

... More
FINAL DISTRIBUTION BOARDS. PART - C - DB's & MCB's : Supply, Installation, Testing and Commissioning of all MCB Distribution Boards (10KA) 415V, made out of 16SWG MS sheet steel enclosure hinged MS cover/over flanged cover (double door) with cutouts for operating the MCB knobs and comprising of phase bus bars, neutrals and earth bus with tapped holes, bakelite phase barriers, pvc insulator shoes for incoming wire, etc complete. DB's shall be mounted by grouting in to the wall/angle to brick wall as required. DB's shall be suitable for Three Phase / single phase loads. Or DB's shall be mounted on suitable M.S. angle and supporting flat. DB's shall include termination lugs etc., all complete. (Note: Local fabrication not permitted. Only factory made boxes shall be installed and all MCB's shall be with 10 KA rating)Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required 8 way (4 + 24), Double door for UPS DB

6

-

-

... More
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) * 8 way double door

9

-

-

... More
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) Comman Lighting DB - LDB - 1 Phase 12 Way, suitable to install the following excluding MCB / RCBO, 'Incoming: 1 No. 40A DP RCBO, Outgoings: 8 Nos. 16/20 A SP MCB, 'D' curve.

1

-

-

... More
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) Comman Raw power DB - RPDB - 1 Phase 12 Way, suitable to install the following excluding MCB / RCBO, 'Incoming: 1 No. 40A DP RCBO, Outgoings: 8 Nos. 16/20 A SP MCB, 'D' curve.

2

-

-

... More
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)Comman UPS power DB - UPSDB - 1 Phase 12 Way, suitable to install the following excluding MCB / RCBO, 'Incoming: 1 No. 40A DP RCBO, Outgoings: 8 Nos. 16/20 A SP MCB, 'D' curve.

1

-

-

... More
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)Emergency Lighting DB - ELDB - 1 Phase 8 Way, suitable to install the following excluding MCB / RCBO, 'Incoming: 1 No. 32A DP RCBO, 30mA, Outgoings: 4 Nos. 10 A SP MCB, 'B' curve.

1

-

-

... More
Supplying fixing and wiring Current Operated RCBOs,240V/415V 50Hz with 10KA short circuit with standing capacity 25amps. double pole, 30/100mA, and Including the cost of all materials, lobour, HANDLING OF MATERIALS of equipment and machinery all lead lift, loading etc, complete.RCBO 63 A, 4P, 30mA - - RPDB & UPS DB

12

-

-

... More
Supplying fixing and wiring Current Operated RCBOs,240V/415V 50Hz with 10KA short circuit with standing capacity 25amps. double pole, 30/100mA, and Including the cost of all materials, lobour, HANDLING OF MATERIALS of equipment and machinery all lead lift, loading etc, complete.RCBO 32/40 A 4P, 30mA - - LDB

6

-

-

... More
Supplying fixing and wiring Current Operated RCBOs,240V/415V 50Hz with 10KA short circuit with standing capacity 25amps. double pole, 30/100mA, and Including the cost of all materials, lobour, HANDLING OF MATERIALS of equipment and machinery all lead lift, loading etc, complete.RCBO 32/40A, DP, 30mA - for LDB + ELDB + RPDB

5

-

-

... More
Supplying and fixing, MCB on existing MCB distribution boards using necessary fixing materials and wiring complete as required and Including the cost of all materials, lobour , HANDLING OF MATERIALS of equipment and machineries all lead lift, loading etc, complete32/40 A TPN MCB - for Hood RPDB

21

-

-

... More
Supplying and fixing, MCB on existing MCB distribution boards using necessary fixing materials and wiring complete as required and Including the cost of all materials, lobour , HANDLING OF MATERIALS of equipment and machineries all lead lift, loading etc, complete32 A TP MCB - for RPDB & UPS DB

48

-

-

... More
Supplying and fixing, MCB on existing MCB distribution boards using necessary fixing materials and wiring complete as required and Including the cost of all materials, lobour , HANDLING OF MATERIALS of equipment and machineries all lead lift, loading etc, complete16 / 20A, SP, MCB - 'C' CURVE for RP & UPS DB's

180

-

-

... More
Supplying and fixing, MCB on existing MCB distribution boards using necessary fixing materials and wiring complete as required and Including the cost of all materials, lobour , HANDLING OF MATERIALS of equipment and machineries all lead lift, loading etc, complete10A, SP, MCB - 'B' CURVE- for LDB & ELDB

92

-

-

... More
Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V "C" curve DP MCB complete with connections, testing and commissioning etc. as required.

112

-

-

... More
Supplying and fixing TPN sheet steel enclosure on surface/ recess without MCB complete with connections, testing and commissioning etc. as required.

21

-

-

... More
Supply and fixing MCCB incomer box with 250 A MCB 4P 50kA

4

-

-

... More
PVC RACEWAYS ( Along the wall) DLP U- PVC adaptable trunking : Supply & installation of surface mounted DLP U- PVC adaptable trunking raceways, fabricated out of U-PVC to Off-White or approved shade as per IS 733 of thickness 2.0mm for the base and sides with removable covers, complete with necessary bends, suitable sized junction boxes, internal angle, external angle, flat 90 degree angle , end caps and tees,minor civil works if any etc, Complete. (For every 1mtr distance cable tag has to be provided for each circuit in the raceways - as more that 1C FRLS copper wire is required for 1 Circuit) PVC RACEWAYS ( Along the wall), DLP U- PVC adaptable trunking . Size: 105x 50mm PVC Raceways for Power & Data with above specifications 105x 50mm PVC Raceways

800

-

-

... More
16 AMP SOCKET: Supplying and fixing following Modular socket on the existing raceways & PVC DLP truncking with required accessories to complete jobs. including connections, as required. (All switches and Sockets shall be spark proof type) 6 Pin 15/16 amp socket outlet

238

-

-

... More
13 AMP SOCKET: Supplying and fixing following Modular switch / socket on the existing raceways & PVC DLP truncking with required accessories to complete jobs. including connections, as required including connections, as required. (All switches and Sockets shall be spark proof type) 13 amp socket outlet

160

-

-

... More
16 AMP Switch: Supplying and fixing following Modular switch / socket on the existing raceways & PVC DLP truncking with required accessories to complete jobs. including connections, as requiredincluding connections, as required. (All switches and Sockets shall be spark proof type) 15/16 amp switch

398

-

-

... More
Supplying and fixing following Modular switch / socket on the existing raceways & PVC DLP truncking with required accessories to complete jobs. including connections, as required including connections, as required. (All switches and Sockets shall be spark proof type) 6 Module Box with faceplate & cover

133

-

-

... More
Supplying and fixing following Modular switch / socket on the existing raceways & PVC DLP truncking with required accessories to complete jobs. including connections, as required including connections, as required. (All switches and Sockets shall be spark proof type) 4 Module Box with faceplate & cover

280

-

-

... More
Supplying and fixing following Modular switch / socket on the existing raceways & PVC DLP truncking with required accessories to complete jobs. including connections, as required including connections, as required. (All switches and Sockets shall be spark proof type) 1/2 Module Box with faceplate & cover

140

-

-

... More
INDUSTRIAL POWER SOCKETS on wall : 32Amp, single phase : Supply and fixing 32A, 3 pin, Single phase, Industrial Socket with safety shutters controlled by One no. of 32A, double Pole MCB to be mounted on wall, ( The job includes cutting & chasing on exisiting wall, fixing the box in position as required including rough plastering.) As per IEC 61439-3. suitable for flush mounting and surface mounting. 3P+ P+E Five pole, IP 44, material of plug & socket polyamide 6. Including the cost of all materials, lobour , HOM of equipment and machinerys all lead lift, loading and unloading,transportation, if any other incidental charges at all level complete all as per specification and as directed by Engineer-incharge. MCB/PLUG/BOX -32A . Make:-

12

-

-

... More
INDUSTRIAL POWER SOCKETS on wall : 32Amp, three phase : Supply and fixing 32A, 5 pin, three phase, Industrial Socket with safety shutters controlled by One no. of 32A, three Pole MCB to be mounted on wall, ( As per IEC 61439-3. suitable for flush mounting and surface mounting. 3P+ P+E Five pole, IP 44, material of plug & socket polyamide 6. The job includes cutting & chasing on exisiting wall, fixing the box in position as required including rough plastering.) Including the cost of all materials, lobour , HOM of equipment and machinerys all lead lift, loading and unloading,transportation, if any other incidental charges at all level complete all as per specification and as directed by Engineer-incharge. MCB/PLUG/BOX - 32A

12

-

-

... More
Light Point Wiring : Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group A

20

-

-

... More
Light Point Wiring : Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group B

90

-

-

... More
Light Point Wiring : Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C

126

-

-

... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes ofFRLS PVC insulated copper conductor, single core cable in surface/ recessedmedium class PVC conduit as required 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire

450

-

-

... More
POWER SWITCHES / SOCKETS on walls - G.I. BOX. : Supplying and fixing following size / modules, GI box along with modular base and cover plate for modular switches in recess etc, as required. ( The job includes cutting & chasing existing wall, fixing the box in position as required including rough plastering.) (In all the rooms, vertical drops of conduits and switch boxes shall be concealed in the wall). Boxes should be of same make as that of modular accessories. :6 Module

76

-

-

... More
LIGHT CIRCUIT WIRING : Wiring for circuit / submain wiring in concealed pipe below false ceiling (by chieseling the wall and covering with chicken mesh with rough plastering) / surface mounted. Including ISI mark PVC Conduit with 25mm DIa of 2mm thick with PVC insulated FRLS single core wires with colour code of following: 2 x 2.5 sqmm + 1 x2.5 sqmm earth wire.

960

-

-

... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 4 sq. mm + 1 X 4 sq. mm earth wire For Raw power

2400

-

-

... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 4 sq. mm + 1 X 4 sq. mm earth wire For UPS power

2600

-

-

... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 4 X 4 sq. mm + 2 X 4 sq. mm earth wire For Raw power

700

-

-

... More
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required 25mm dia conduit pipe (2mm) - Raw Power in Floor

500

-

-

... More
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required 32mm dia conduit pipe (2mm) - Power

300

-

-

... More
Supply of Recessed/Surface Mounted 2'X2' , 36 / 40 W LED Luminaire with Intelligent Inner Edge Light with Single piece molded Polycarbonate diffuser, Lighting and electrical parameters are inline with 2'X2' Luminaire. Luminaire should give more volumetric light & higher vertical illumination.Luminaire should be available in different Lumen Packs of 4000 lm with different CCT.. LED Used shall be SMD type and fixture should have minimum efficacy at System level (Not Chip Level) =100 lumens/watt, Life of fixture 50000hrs@L70% Lumen maintenance, CCT up to 6500, CRI 80, PF 0.95 and SDCM 4 for good light quality, an operating Voltage Range of 140 - 270 V.Minimum Internal Surge Protection 2.5KV The fixture should comply with the parameters as per IS10322. The LED driver should comply to IEC61000-3-2 ed.3.2, 2009 for Harmonics, IEC61347 -2 -13, 2006 in Conjunction with IEC61347-1 ed.2.0, 2007 for Electrical Safety, IEC62384 ed.1.1, 2011 for performance and IEC61547 ed.2.0, 2009, CISPR-15 for EMI. Manufacturer shall have inhouse lab approved by NABL or ministry of science of govt of India. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters. Make Wipro / Crompton / Havell / Bajaj

220

-

-

... More
ERECTION for Recessed/Surface Mounted 2'X2' , 36 / 40 W LED Luminaire incluilding ceiling hook, drop wires 3 R x 1.5 sqmm copper flex wire from ceiling point to fitting with full covered flex pipe, stray wire / cable for handing fitting on false ceiling or mouting on ceiling with surface box assembly etc as required and complete. Cutting in metal / false ceiling for required cut out is in scope of agency.

220

-

-

... More
Supply of Recessed/Surface Mounted 12 watt LED Luminaire round/squre dia 165 mm cut out type with Intelligent Inner Edge Light with Single piece molded Polycarbonate diffuser, Lighting and electrical parameters are inline with 1'X1' Luminaire. Luminaire should give more volumetric light & higher vertical illumination.Luminaire should be available in different Lumen Packs of 1200 lm with different CCT.Luminaire should accommodate different color tiles & also accommodate Services like and maximum system wattage of 12 W, LED Used shall be SMD type and fixture should have minimum efficacy at System level (Not Chip Level) =100lumens/watt, Life of fixture 50000hrs@L70% Lumen maintenance, CCT up to 6500, CRI 80, PF 0.95 and SDCM 4 for good light quality, an operating Voltage Range of 140 - 270 V.Minimum Internal Surge Protection 2.5KV The fixture should comply with the parameters as per IS10322. The LED driver should comply to IEC61000-3-2 ed.3.2, 2009 for Harmonics, IEC61347 -2 -13, 2006 in Conjunction with IEC61347-1 ed.2.0, 2007 for Electrical Safety, IEC62384 ed.1.1, 2011 for performance and IEC61547 ed.2.0, 2009, CISPR-15 for EMI. Manufacturer shall have inhouse lab approved by NABL or ministry of science of govt of India. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters Make Wipro / Crompton / Havell / Bajaj

98

-

-

... More
ERECTION for Recessed/Surface Mounted 12 watt LED Luminaire round/squre dia 165 mm cut out type incluilding ceiling hook, drop wires 3 R x 1.5 sqmm copper flex wire from ceiling point to fitting with full covered flex pipe, stray wire / cable for handing fitting on false ceiling or mouting on ceiling with surface box assembly etc as required and complete. Cutting in metal / false ceiling for required cut out is in scope of agency.

98

-

-

... More
Supply surface mounted 20W LED batten type fitting complete with all accessories Including the cost of all materials, labour, HOM of equipment and machinerys all lead, lift, loading and unloading, transportation, if any other incidental charges at all level complete all as per specification and as directed by Engineer-incharge. The fitting shall be green as per ECBC norms. .Make Wipro / Crompton / Havell / Bajaj

20

-

-

... More
ERECTION for surface mounted 20W LED batten type fitting incluilding ceiling hook, drop wires 3 R x 1.5 sqmm copper flex wire from ceiling point to fitting with full covered flex pipe, stray wire / cable for handing fitting on false ceiling or mouting on ceiling with surface box assembly etc as required and complete. Cutting in metal / false ceiling for required cut out is in scope of agency.

20

-

-

... More
Supply of reccess/ surface mounted 9 watt 5" LED Recessed Downlighter with a nominal system lumen output of 600 lumens and a minimum system efficacy of 110 lm/W. The luminaire shall have a rated system lifetime of 50,000 burning hours at L70. The luminaire should have a color temperature of 6500K and CRI80. The luminaire shall meet IP20 rating with THD10% and PF 0.95 and 2.5KV surge protection. The luminaire housing should made of pressure die cast aluminium and the luminaire optics shall have a high efficiency diffuser with more than 85% transmittance. The total power consumption should not exceed 5.5W (including driver).The fixture should comply with the parameters as per IS10322. The LED driver should comply to IEC61000-3-2 ed.3.2, 2009 for Harmonics, IEC61347 -2 -13, 2006 in Conjunction with IEC61347-1 ed.2.0, 2007. Make Wipro / Crompton / Havell / Bajaj

20

-

-

... More
ERECTION for reccess/ surface mounted 9 watt 5" LED Recessed Downlighter incluilding ceiling hook, drop wires 3 R x 1.5 sqmm copper flex wire from ceiling point to fitting with full covered flex pipe, stray wire / cable for handing fitting on false ceiling or mouting on ceiling with surface box assembly etc as required and complete. Cutting in metal / false ceiling for required cut out is in scope of agency.

20

-

-

... More
Supplying and fixing exhaust fan of 1440 RPM of 305 mm (12") sweep with bracket blades complete for light duty of approved make. Louvers are required for each fan with 230V, single phase, 50 Hz. Including the cost of all materials, labour , HOM of equipment and machinerys all lead lift, loading and unloading, transportation, if any other incidental charges at all level complete all as per specification and as directed by Engineer-incharge. Frame for installation will be under civil scope of works.

3

-

-

... More
ERECTION for exhaust fan of 1440 RPM of 305 mm (12") sweep incluilding wall maounting arragement, drop wires 3 R x 1.5 sqmm copper flex wire from ceiling point to fitting with full covered flex pipe, nutbolts / fasners etc with surface box assembly etc as required and complete. Cutting in metal / false ceiling for required cut out is in scope of agency.

3

-

-

... More
50 mm X 5 mm copper earth strip : Providing and fixing earth bus of 50 mm X 5 mm copper strip on surface for connections etc, as required.

50

-

-

... More
25 mm X 5 mm copper earth strip on surface: Providing and fixing 25 mm X 5 mm copper stripfrom earth electrode as required.

30

-

-

... More
25 mm X 5 mm GI earth strip on surface: Providing and fixing 25 mm X 5 mm GI strip from earth electrode as required.

300

-

-

... More
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. 1 run of cable

1000

-

-

... More
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required.2 run of cable

1200

-

-

... More
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. 3 run of cable

2000

-

-

... More
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required ( for Data cable ) 40 MM

280

-

-

... More
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required ( for Data cable ) 25 MM

600

-

-

... More
Supply and making end termination for UTP 4 pair CAT 6 LAN cable with required IO modules which is suitable for modular type base , cover plates and accessories ( At field side ) as required.Quoted rate shall be including material, labour, taxes, duties, lead, lift, loading, transportation, unloading, storing , scaffolding etc, making holes in walls , filling holes with mortar etc complete as per direction of Engineer In‐charge. Nothing extra shall be paid separately.

150

-

-

... More
Supply and making end termination for UTP 4 pair CAT 6 LAN cable with required IO modules which is suitable for modular type base , cover plates and accessories ( At Rackside side ) as required.Quoted rate shall be including material, labour, taxes, duties, lead, lift, loading, transportation, unloading, storing , scaffolding etc, making holes in walls , filling holes with mortar etc complete as per direction of Engineer In‐charge. Nothing extra shall be paid separately.

150

-

-

... More
Supply of 2meter length cat 6 patch cord with Rj 45 terminations on both ends as complete.

280

-

-

... More
Supply and installation of 48 port fully loaded patch panel with IO modules suitable for UTP CAT 6 cable and required mounting accessories for existing network rack.Quoted rate shall be including material, labour, taxes, duties, lead, lift, loading, transportation, unloading, storing , scaffolding etc, making holes in walls , filling holes with mortar etc complete as per direction of Engineer In‐ charge. Nothing extra shall be paid separately.

8

-

-

... More
Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required.

12

-

-

... More
Jointing copper / G.I. tape (with another copper/ G I tape, base of the finial or any other metallic object) by riveting / nut bolting/ sweating and soldering etc as required.

12

-

-

... More
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run)

240

-

-

... More
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run)

40

-

-

... More
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.

4

-

-

... More
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.

6

-

-

... More
Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required.

10

-

-

... More
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 meter below ground as strip earth electrode, including connection/terminating with G.I. nut, bolt, spring, washer etc. as required.(Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)

100

-

-

... More
Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.

20

-

-

... More
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.

500

-

-

... More
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.

25

-

-

... More
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required.

50

-

-

... More
EARTH BUS : Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut,bolt, spring, washer excavation and re-filling etc. as required.

2

-

-

... More
Providing excavation and refilling of existing earthing pit GI / Copper with Charcoal 90 Kg , solt 30 kg each. Works includes cleaning of all GI/ Copper parts of earthing pit, replacement of connecting nutbolts with new SS nutbolts, replacement of water pipe GI having identical specifications with existing one, if required. Reconstruction of earthing chamber with 450 x 450 size CI cover. Earthing test report should be submitted by the agency as per format issued by IISER Pune. Before execution of work, prior approval from engineer in charge, IISER Pune is required. Work shall be executed as good workmenship.

10

-

-

... More
Repairing and reconstruction of earthing chamber with CI 450 x 450 mm cover , as per instructions of Engineer in charge, IISER Pune

40

-

-

... More
Supply, Installation, Testing and Commissioning of 3 Phase, 4 wire, 415 V, 0.8 P.F, 50 Hz panels. The fabrication shall be made with cold rolled cold annealed sheet with Machine pressing. The surface shall be rigorously treated for derusting in 7tank process with dephosphating and with powder coating on both sides of the panel. The panel shall be totally enclosed metal clad type with double gasketting with rubber / resin lining. The panel shall be having control directory pasted inside the panel. The panel shall be mounted on existing trench and shall have cable entry provision from the top and bottom with suitable alley as the case may be. All components shall be from ISO-9001companies and shall have relevant IS/IEC approvals without fail. (Fabrication, drawing and list of components and panel detail shall be got approved by consultants before fabrication). The panel shall include base frame channel support. (The Single Line Diagram shall be closely followed).Note: 1.1. The Panel shall be fully as per the requirement of Engineer-in-charge. 2. Auxiliary contactor to be provided along with auto-manual switch where ever required.3. All Breakers both Incoming & Outgoing shall have LED 'ON / OFF / TRIP' indications without fail.4. CTs shall be with dual ratio and cast resin type only.5. For Capacitors earthing shall be provided.6. Ventilators shall be provided for Panels with 2500A & above rated bus bars.7. Cu bus earthing shall be provided for all panels.8. Circuit Breakers shall confirm IS 13947-2/IEC 947-2 9. All doors to have double rubber gasket with shutter assembly & door seating frame.10. All AC feeders will have time delays of 0-60 Seconds with timers.11. All breakers more than 250A will be microprocessor based only and less than 250A breaker shall be Thermal based releases.12.Any panel if more than 1.5m width should be made in parts each part not exceeding 1.5m13. The current density for ALU bus bars shall be 0.8 only.14. The current density for CU bus bars shall be 1.0 only.15.All UPS outgoing panels shall have neutral bus bars double size of phase.16. TP means three pole17. TPN means 3 pole breaker with neutral link18. 4P means Four Pole breaker with 100% neutral19. Unless specified as 3.5 pole breaker, 4 pole means 4 pole ONLY.20. All breakers to have breaker manufacturer's factory made Separators and Spreaders..21. In any case Aluminium bus bars should not be connected directly to the breaker without spreaders.22. The control wiring has to be in Troughs of appropriate size.23. Irrespective of the Ampacity all breakers shall be connected to the breakers using Bus bars only. Cables of any make will never be accepted.24. All vertical bus bars in bus bar alley shall have bottom supports.25. Panel earthing strip should come out vertically on top of the panel.26. Earthing bus shall be coated to give a look of tin.27. Door earthing shall be provided for all doors.28. Base frame shall be with each panel. The size will be equal to each section.29. Bi-metallic tape/washers to be used where ever Cu. & Al are joined.30. All test certificates must be provided immediately after commissioning.31. SAFETY CERTIFICATE FOR THE PANELS SHALL BE PRODUCED FROM CEIG.32. Panel General Arrangement drawing must be provided for approval before fabrication.33. Makes of material must be provided for approval 34. Cubicle Details : Material of construction - CRCA - 16/14 SWG, IP Protection - IP - 52, Indoor cubicle type free standing & floor mounting, Front/Rear panels - Hinged doors/ Removable type, Gland plates - Undrilled, dust & vermin proofbefore procurement35. Cable entry details : Incoming - All cables are from top / bottom, Outgoings - All outgoings by cables from top (iTEM DESCRIPTION61.0 IS COMMON FOR ITME NO 61TO 67)

-

-

-

... More
HPC UPS incoming RAW PANEL : Supply, installation, testing and commissioning of LT panel as per following specifications. Drawing, SLD, GA, BOM & specifications should be submitted to IISER Pune for approval before manufactureing of panel.Supply, installation, testing and commissioning of 3 phase, 4 wire, 415 KV, 0.8 PF, 50 HZ panels. The fabrication shall be made with 14 SWG cold rolled sheet with M/C pressing, powder coated. The surface shall be rigorously treated for derusting in 7 tank process with dephosphating & paintingwith at least 2 coats of approved paint. The panel shall be totally enclosed metal clad type with double gasketting with rubber/ resin lining. The panel shall be having control directory pasted inside the panel. The panel shall be mounted on existing trench/ floor & shall have cable entry provision from the top & bottom with suitable alley as the case may be. The panel shall be tested for the same KA rating of the relevant highhest rating of MCCB. All components shall be from ISO-9001 companies and shall have relevant IS/IES approvals without fail. The panel shall be fully interlocked as required. The panel shall include baseframe channel support. ( The single line daigram shall be closely followed) 1. The panel shall be design as per norms of CEIG/ PWD/ CPWD/ Maharashtra State Electricity Distribution Company Ltd 2. Auxilliary contractor to be provided along with Auto-manual switch where ever required. 3. Ventilators shall be provided for Panels with rated bus bars.4. Al bus earthing shall be provided for all panels.5. Circuit Breakers shall confirm IS 13947-2IEC 947-26. All doors to have double rubber gasket with shutter assembly & door seating frame.7. The UPS outgoing panels shall have neutral busbars double the size of phase.8. All breaker to have breaker manufacturer's factory made Spreaders.9. In any case Aluminium busbar should not be connected directly to breaker without spreaders.10. The control wiring has to be in appropriate size with MCB protection. 11. Irrespective of the Amp. Capacity all breakers shall be connected to the breakers using busbar only.12. All vertical bus bars in bus bar alley shall have bottem supports.13. All panels shall have top entry only.14. Panel earthing strip should come out vertically on top the panel.15. Earthing bus shall be coated to give a look of tin.16. All indication should be proper colour and with protection of MCB.17. All meters should have protetion of MCB.18. Door earthings shall be provided for all doors.19. Suitable for termination of upto 3 1/2 C x 150 sqmm alrmould cable for each feeder. RAW panel incoming panel : 1 A) Cubicle Details:Material of construction- CRCA-14 SWGIP, Protection- IP-52 as per IS 2147, Indoor cubicle type free standing & floor mounting, front/Rear panels- Hinged doors/ Removeble type , Gland plates-Undriled, dust & vermin proof. Cables entry details:Incoming- All cables are from top Outgoing- All outgoings by cables from top B) Meters: 3 Phase 4 Wire, 440 Volts, Digital meters for Parameters Volt, Amp, Hz, KVA, KW etc, auto scrolling facility, panel mounting on door, suitable for 96 x 96 mm. Range- 0-500V, 10 Amps.DigitalKWH meter with CT's and selector switch. Range-400 Amps.BUS BAR: 800 A, TPN, 415V, 3 Phase, 50 Hz, Aluminium Bus Bar. Bus Bar Supports- FRP. Bus Bar sleeves- Heat shirkable- colour coded.Internal & control wiring- To be with ferrulesHeat resistant type, 1100V grade single core copper flexible. C) Incomer:MCCB: Quantity- 01 No.Rating- 400 amps- 35 KA. (Legrand/ L&T/ Siemense) Type-MDO Operation - manual No. of Poles- 4 P, Release- OC/ SC/ EF/ ST. Indications- RYB/ Off/ ON/ Trip. Other features- All standard. Auxillary Contactors:Quantity- As required.Rating- 6 Amps.CT's- Measurement- 2 sets.Class- 15 VA burden.Type- Cast resin.Ratio- 400/ 5 D) Outgoing: MCCB: Quantity- 03 Nos. Rating- 250 amps- 25 KA. (Legrand/ L&T/ Siemense)Type-ManualNo. of Poles- TPNRelease- OC/ SC/ ST. Indications- On No. of Poles- 3P+N Release- OC/ SC/ ST. Indications- On Quoted rates shall be including all taxes,duties,royalties,lead,lift,transpotation,GST etc complete.Nothing shall be payable separtely. Work shall be executed as per direction of engineer in charge,IISER Pune. Actual installation of MS powder coated encloser with all accessories & provision mentioned above at site shall be measured for payments.

1

-

-

... More
Chemistry wing second floor AHU panel : Supply, installation, testing and commissioning of LT panel as per following specifications. Drawing, SLD, GA, BOM & specifications should be submitted to IISER Pune for approval before manufactureing of panel.Supply, installation, testing and commissioning of 3 phase, 4 wire, 415 KV, 0.8 PF, 50 HZ panels. The fabrication shall be made with 14 SWG cold rolled sheet with M/C pressing, powder coated. The surface shall be rigorously treated for derusting in 7 tank process with dephosphating & paintingwith at least 2 coats of approved paint. The panel shall be totally enclosed metal clad type with double gasketting with rubber/ resin lining. The panel shall be having control directory pasted inside the panel. The panel shall be mounted on existing trench/ floor & shall have cable entry provision from the top & bottom with suitable alley as the case may be. The panel shall be tested for the same KA rating of the relevant highhest rating of MCCB. All components shall be from ISO-9001 companies and shall have relevant IS/IES approvals without fail. The panel shall be fully interlocked as required. The panel shall include baseframe channel support. ( The single line daigram shall be closely followed) 1. The panel shall be design as per norms of CEIG/ PWD/ CPWD/ Maharashtra State Electricity Distribution Company Ltd 2. Auxilliary contractor to be provided along with Auto-manual switch where ever required. 3. Ventilators shall be provided for Panels with rated bus bars.4. Al bus earthing shall be provided for all panels.5. Circuit Breakers shall confirm IS 13947-2IEC 947-26. All doors to have double rubber gasket with shutter assembly & door seating frame.7. The UPS outgoing panels shall have neutral busbars double the size of phase.8. All breaker to have breaker manufacturer's factory made Spreaders.9. In any case Aluminium busbar should not be connected directly to breaker without spreaders.10. The control wiring has to be in appropriate size with MCB protection. 11. Irrespective of the Amp. Capacity all breakers shall be connected to the breakers using busbar only.12. All vertical bus bars in bus bar alley shall have bottem supports.13. All panels shall have top entry only.14. Panel earthing strip should come out vertically on top the panel.15. Earthing bus shall be coated to give a look of tin.16. All indication should be proper colour and with protection of MCB.17. All meters should have protetion of MCB.18. Door earthings shall be provided for all doors.19. Suitable for termination of upto 3 1/2 C x 150 sqmm alrmould cable for each feeder. RAW panel incoming panel : 1 A) Cubicle Details:Material of construction- CRCA-14 SWGIP, Protection- IP-52 as per IS 2147, Indoor cubicle type free standing & floor mounting, front/Rear panels- Hinged doors/ Removeble type , Gland plates-Undriled, dust & vermin proof. Cables entry details:Incoming- All cables are from top Outgoing- All outgoings by cables from top B) Meters: 3 Phase 4 Wire, 440 Volts, Digital meters for Parameters Volt, Amp, Hz, KVA, KW etc, auto scrolling facility, panel mounting on door, suitable for 96 x 96 mm. Range- 0-500V, 10 Amps.DigitalKWH meter with CT's and selector switch. Range-400 Amps.BUS BAR: 800 A, TPN, 415V, 3 Phase, 50 Hz, Aluminium Bus Bar. Bus Bar Supports- FRP. Bus Bar sleeves- Heat shirkable- colour coded.Internal & control wiring- To be with ferrulesHeat resistant type, 1100V grade single core copper flexible. C) Incomer :- 3P, 250A MCCB with Operating Handle, 35 kA. (Legrand/ L&T/ Siemense) Type-MDO Operation - manual No. of Poles- 4 P, Release- OC/ SC/ EF/ ST. Indications- RYB/ Off/ ON/ Trip. Other features- All standard. Auxillary Contactors:Quantity- As required.Rating- 6 Amps.CT's- Measurement- 2 sets.Class- 15 VA burden.Type- Cast resin.Ratio- 400/ 5 D) Outgoing: MCCB: Quantity- 12 Nos. Rating- 32 amps- 25 KA. 3 P. (Legrand/ L&T/ Siemense)Type-ManualNo. of Poles- TPNRelease- OC/ SC/ ST. Indications- On No. of Poles- 3P+N Release- OC/ SC/ ST. Indications- On Quoted rates shall be including all taxes,duties,royalties,lead,lift,transpotation,GST etc complete.Nothing shall be payable separtely. Work shall be executed as per direction of engineer in charge,IISER Pune. Actual installation of MS powder coated encloser with all accessories & provision mentioned above at site shall be measured for payments.

1

-

-

... More
UPS & RAW Floor PANEL : Supply, installation, testing and commissioning of LT panel as per following specifications. Drawing, SLD, GA, BOM & specifications should be submitted to IISER Pune for approval before manufactureing of panel.Supply, installation, testing and commissioning of 3 phase, 4 wire, 415 KV, 0.8 PF, 50 HZ panels. The fabrication shall be made with 14 SWG cold rolled sheet with M/C pressing, powder coated. The surface shall be rigorously treated for derusting in 7 tank process with dephosphating & paintingwith at least 2 coats of approved paint. The panel shall be totally enclosed metal clad type with double gasketting with rubber/ resin lining. The panel shall be having control directory pasted inside the panel. The panel shall be mounted on existing trench/ floor & shall have cable entry provision from the top & bottom with suitable alley as the case may be. The panel shall be tested for the same KA rating of the relevant highhest rating of MCCB. All components shall be from ISO-9001 companies and shall have relevant IS/IES approvals without fail. The panel shall be fully interlocked as required. The panel shall include baseframe channel support. ( The single line daigram shall be closely followed) 1. The panel shall be design as per norms of CEIG/ PWD/ CPWD/ Maharashtra State Electricity Distribution Company Ltd 2. Auxilliary contractor to be provided along with Auto-manual switch where ever required. 3. Ventilators shall be provided for Panels with rated bus bars.4. Al bus earthing shall be provided for all panels.5. Circuit Breakers shall confirm IS 13947-2IEC 947-26. All doors to have double rubber gasket with shutter assembly & door seating frame.7. The UPS outgoing panels shall have neutral busbars double the size of phase.8. All breaker to have breaker manufacturer's factory made Spreaders.9. In any case Aluminium busbar should not be connected directly to breaker without spreaders.10. The control wiring has to be in appropriate size with MCB protection. 11. Irrespective of the Amp. Capacity all breakers shall be connected to the breakers using busbar only.12. All vertical bus bars in bus bar alley shall have bottem supports.13. All panels shall have top entry only.14. Panel earthing strip should come out vertically on top the panel.15. Earthing bus shall be coated to give a look of tin.16. All indication should be proper colour and with protection of MCB.17. All meters should have protetion of MCB.18. Door earthings shall be provided for all doors.19. Suitable for termination of upto 3 1/2 C x 150 sqmm alrmould cable for each feeder. RAW panel incoming panel : 1 A) Cubicle Details:Material of construction- CRCA-14 SWGIP, Protection- IP-52 as per IS 2147, Indoor cubicle type free standing & floor mounting, front/Rear panels- Hinged doors/ Removeble type , Gland plates-Undriled, dust & vermin proof. Cables entry details:Incoming- All cables are from top Outgoing- All outgoings by cables from top B) Meters: 3 Phase 4 Wire, 440 Volts, Digital meters for Parameters Volt, Amp, Hz, KVA, KW etc, auto scrolling facility, panel mounting on door, suitable for 96 x 96 mm. Range- 0-500V, 10 Amps.DigitalKWH meter with CT's and selector switch. Range-400 Amps.BUS BAR: 800 A, TPN, 415V, 3 Phase, 50 Hz, Aluminium Bus Bar. Bus Bar Supports- FRP. Bus Bar sleeves- Heat shirkable- colour coded.Internal & control wiring- To be with ferrulesHeat resistant type, 1100V grade single core copper flexible. C) Incomer:MCCB: Quantity- 01 No.Rating- 250 amps- 35 KA. (Legrand/ L&T/ Siemense) Type-MDO Operation - manual No. of Poles- 4 P, Release- OC/ SC/ EF/ ST. Indications- RYB/ Off/ ON/ Trip. Other features- All standard. Auxillary Contactors:Quantity- As required.Rating- 6 Amps.CT's- Measurement- 2 sets.Class- 15 VA burden.Type- Cast resin.Ratio- 400/ 5 D) Outgoing: ROCB Quantity- 15 Nos. Four pole 100 mA 32 A. E ) Outgoing: ROCB Quantity- 10 Nos. Double pole 100 mA, 32 A. (Legrand/ L&T/ Siemense). Quoted rates shall be including all taxes,duties,royalties,lead,lift,transpotation,GST etc complete.Nothing shall be payable separtely. Work shall be executed as per direction of engineer in charge,IISER Pune. Actual installation of MS powder coated encloser with all accessories & provision mentioned above at site shall be measured for payments.

2

-

-

... More
LDB Floor PANEL : Supply, installation, testing and commissioning of LT panel as per following specifications. Drawing, SLD, GA, BOM & specifications should be submitted to IISER Pune for approval before manufactureing of panel.Supply, installation, testing and commissioning of 3 phase, 4 wire, 415 KV, 0.8 PF, 50 HZ panels. The fabrication shall be made with 14 SWG cold rolled sheet with M/C pressing, powder coated. The surface shall be rigorously treated for derusting in 7 tank process with dephosphating & paintingwith at least 2 coats of approved paint. The panel shall be totally enclosed metal clad type with double gasketting with rubber/ resin lining. The panel shall be having control directory pasted inside the panel. The panel shall be mounted on existing trench/ floor & shall have cable entry provision from the top & bottom with suitable alley as the case may be. The panel shall be tested for the same KA rating of the relevant highhest rating of MCCB. All components shall be from ISO-9001 companies and shall have relevant IS/IES approvals without fail. The panel shall be fully interlocked as required. The panel shall include baseframe channel support. ( The single line daigram shall be closely followed) 1. The panel shall be design as per norms of CEIG/ PWD/ CPWD/ Maharashtra State Electricity Distribution Company Ltd 2. Auxilliary contractor to be provided along with Auto-manual switch where ever required. 3. Ventilators shall be provided for Panels with rated bus bars.4. Al bus earthing shall be provided for all panels.5. Circuit Breakers shall confirm IS 13947-2IEC 947-26. All doors to have double rubber gasket with shutter assembly & door seating frame.7. The UPS outgoing panels shall have neutral busbars double the size of phase.8. All breaker to have breaker manufacturer's factory made Spreaders.9. In any case Aluminium busbar should not be connected directly to breaker without spreaders.10. The control wiring has to be in appropriate size with MCB protection. 11. Irrespective of the Amp. Capacity all breakers shall be connected to the breakers using busbar only.12. All vertical bus bars in bus bar alley shall have bottem supports.13. All panels shall have top entry only.14. Panel earthing strip should come out vertically on top the panel.15. Earthing bus shall be coated to give a look of tin.16. All indication should be proper colour and with protection of MCB.17. All meters should have protetion of MCB.18. Door earthings shall be provided for all doors.19. Suitable for termination of upto 3 1/2 C x 150 sqmm alrmould cable for each feeder. RAW panel incoming panel : 1 A) Cubicle Details:Material of construction- CRCA-14 SWGIP, Protection- IP-52 as per IS 2147, Indoor cubicle type free standing & floor mounting, front/Rear panels- Hinged doors/ Removeble type , Gland plates-Undriled, dust & vermin proof. Cables entry details:Incoming- All cables are from top Outgoing- All outgoings by cables from top B) Meters: 3 Phase 4 Wire, 440 Volts, Digital meters for Parameters Volt, Amp, Hz, KVA, KW etc, auto scrolling facility, panel mounting on door, suitable for 96 x 96 mm. Range- 0-500V, 10 Amps.DigitalKWH meter with CT's and selector switch. Range-400 Amps.BUS BAR: 800 A, TPN, 415V, 3 Phase, 50 Hz, Aluminium Bus Bar. Bus Bar Supports- FRP. Bus Bar sleeves- Heat shirkable- colour coded.Internal & control wiring- To be with ferrulesHeat resistant type, 1100V grade single core copper flexible. C) Incomer:MCCB: Quantity- 01 No.Rating- 250 amps- 35 KA. (Legrand/ L&T/ Siemense) Type-MDO Operation - manual No. of Poles- 4 P, Release- OC/ SC/ EF/ ST. Indications- RYB/ Off/ ON/ Trip. Other features- All standard. Auxillary Contactors:Quantity- As required.Rating- 6 Amps.CT's- Measurement- 2 sets.Class- 15 VA burden.Type- Cast resin.Ratio- 400/ 5 D ) Outgoing: ROCB Quantity- 15 Nos. Double pole 100 mA, 32 A. (Legrand/ L&T/ Siemense). Quoted rates shall be including all taxes,duties,royalties,lead,lift,transpotation,GST etc complete.Nothing shall be payable separtely. Work shall be executed as per direction of engineer in charge,IISER Pune. Actual installation of MS powder coated encloser with all accessories & provision mentioned above at site shall be measured for payments.

1

-

-

... More
2.2 KW VFD panel or fan CFM 4000 : Supply, installation, testing and commissioning of LT panel as per following specifications. Drawing, SLD, GA, BOM & specifications should be submitted to IISER Pune for approval before manufactureing of panel.Supply, installation, testing and commissioning of 3 phase, 4 wire, 415 KV, 0.8 PF, 50 HZ panels. The fabrication shall be made with 14 SWG cold rolled sheet with M/C pressing, powder coated. The surface shall be rigorously treated for derusting in 7 tank process with dephosphating & paintingwith at least 2 coats of approved paint. The panel shall be totally enclosed metal clad type with double gasketting with rubber/ resin lining. The panel shall be having control directory pasted inside the panel. The panel shall be mounted on existing trench/ floor & shall have cable entry provision from the top & bottom with suitable alley as the case may be. The panel shall be tested for the same KA rating of the relevant highhest rating of MCCB. All components shall be from ISO-9001 companies and shall have relevant IS/IES approvals without fail. The panel shall be fully interlocked as required. The panel shall include baseframe channel support. ( The single line daigram shall be closely followed) 1. The panel shall be design as per norms of CEIG/ PWD/ CPWD/ Maharashtra State Electricity Distribution Company Ltd 2. Auxilliary contractor to be provided along with Auto-manual switch where ever required. 3. Ventilators shall be provided for Panels with rated bus bars.4. Al bus earthing shall be provided for all panels.5. Circuit Breakers shall confirm IS 13947-2IEC 947-26. All doors to have double rubber gasket with shutter assembly & door seating frame.7. The UPS outgoing panels shall have neutral busbars double the size of phase.8. All breaker to have breaker manufacturer's factory made Spreaders.9. In any case Aluminium busbar should not be connected directly to breaker without spreaders.10. The control wiring has to be in appropriate size with MCB protection. 11. Irrespective of the Amp. Capacity all breakers shall be connected to the breakers using busbar only.12. All vertical bus bars in bus bar alley shall have bottem supports.13. All panels shall have top entry only.14. Panel earthing strip should come out vertically on top the panel.15. Earthing bus shall be coated to give a look of tin.16. All indication should be proper colour and with protection of MCB.17. All meters should have protetion of MCB.18. Door earthings shall be provided for all doors.19. Suitable for termination of upto 3 1/2 C x 150 sqmm alrmould cable for each feeder. RAW panel incoming panel : 1 A) Cubicle Details:Material of construction- CRCA-14 SWGIP, Protection- IP-52 as per IS 2147, Indoor cubicle type free standing & floor mounting, front/Rear panels- Hinged doors/ Removeble type , Gland plates-Undriled, dust & vermin proof. Cables entry details:Incoming- All cables are from top Outgoing- All outgoings by cables from top B) Meters: 3 Phase 4 Wire, 440 Volts, Digital meters for Parameters Volt, Amp, Hz, KVA, KW etc, auto scrolling facility, panel mounting on door, suitable for 96 x 96 mm. Range- 0-500V, 10 Amps.DigitalKWH meter with CT's and selector switch. , 415V, 3 Phase, 50 Hz, Aluminium Bus Bar. Bus Bar Supports- FRP. Bus Bar sleeves- Heat shirkable- colour coded.Internal & control wiring- To be with ferrulesHeat resistant type, 1100V grade single core copper flexible. On Quoted rates shall be including all taxes,duties,royalties,lead,lift,transpotation,GST etc complete.Nothing shall be payable separtely. Work shall be executed as per direction of engineer in charge,IISER Pune. Actual installation of MS powder coated encloser with all accessories & provision mentioned above at site shall be measured for payments. Details of compenent of panel is as below :

-

-

-

... More
2.2 KW VFD panel or fan CFM 4000 1 MCB 10 A TP 10 Ka C curve, 1 Nos 2 Contactor , 3 pole, coil 240 V Ac, 9 A power NMX 9, 1 no 3 Nos 3 Add on block 2 No+2NC for MNX 9-40 A/MCX 0-12 A 3 Nos 4 Contactor, Auxillary, coil 240 V AC 7.5A, 2 NO+2NC MXO 22 E 1 Nos 5 Add on block 3 NO + 1 NC Mx-A1 31 E 1 Nos 6 Overload replay, 3-5 A , direct mtg 1 Nos 7 Overload relay, direct mtg kit 1 Nos 8 MCB 6 A SP 10 Ka C curve, 4 Nos 9 Indicating lamp, LED 22 mm dia 240 V Red 1 Nos 10 Indicating lamp, LED 22 mm dia 240 V Green 1 Nos 11 Indicating lamp, LED 22 mm dia 240 V Yellow 1 Nos 12 Push button, flush, Red 1 Nos 13 Push button, flush, Green 1 Nos 14 Contact Element 1 NO 1 Nos 15 contact Element 1 NC 1 Nos 16 Voltmeter 0-500 V AC, 96 x96 mm MI, CL.1, analog type flush mtg 1 Nos 17 Ammeter 10 A, MI, CTR 5 A, 96x96 mm CL.1 1 Nos18 CT, moulded case, flame retardant 10 A, CTR 5 A, VA 5 , CL :1 3 Nos 19 Selector switch, 6 A, 2 P, 2 way off rotary 1 Nos 20 Control transformer 230/24 V AV, 50 VA 1 Nos 21 Exhaust cooling fan 4" 230 VAC supply 1 Nos 22 Filter 4 " size 2 Nos 23 2.2 KW VFD 440 VAC for HVAV basic VFD 1 Nos 24 Selector switch , 6 A, 3P, 2 way, with off rotary 1 Nos 25 4 sqmm wire FRLS copper PVC insulalted 10 meter 26 1.5 sqmm wire FRLS copper PVC insulated 30 meter 27 Connectors for wire and cable terminations 12 Nos 28 Speaders for outgoing and incoming MCCB to cable 2 Kg 29 Aluminium busbar size 50 mm x 5 mm 30 Aluminium busbar size 100 mm x 10 mm 31 Aluminium busbar size 30 mm x 5 mm 2 Kg 32 Fabricated panel with 2 mm CRCA sheet , powder coated white shade 2 sqm 33 Mounting fabrication hooks for wall mounting 1 Nos

1

-

-

... More
3.7 KW VFD panel or fan CFM 6000 : Supply, installation, testing and commissioning of LT panel as per following specifications. Drawing, SLD, GA, BOM & specifications should be submitted to IISER Pune for approval before manufactureing of panel.Supply, installation, testing and commissioning of 3 phase, 4 wire, 415 KV, 0.8 PF, 50 HZ panels. The fabrication shall be made with 14 SWG cold rolled sheet with M/C pressing, powder coated. The surface shall be rigorously treated for derusting in 7 tank process with dephosphating & paintingwith at least 2 coats of approved paint. The panel shall be totally enclosed metal clad type with double gasketting with rubber/ resin lining. The panel shall be having control directory pasted inside the panel. The panel shall be mounted on existing trench/ floor & shall have cable entry provision from the top & bottom with suitable alley as the case may be. The panel shall be tested for the same KA rating of the relevant highhest rating of MCCB. All components shall be from ISO-9001 companies and shall have relevant IS/IES approvals without fail. The panel shall be fully interlocked as required. The panel shall include baseframe channel support. ( The single line daigram shall be closely followed) 1. The panel shall be design as per norms of CEIG/ PWD/ CPWD/ Maharashtra State Electricity Distribution Company Ltd 2. Auxilliary contractor to be provided along with Auto-manual switch where ever required. 3. Ventilators shall be provided for Panels with rated bus bars.4. Al bus earthing shall be provided for all panels.5. Circuit Breakers shall confirm IS 13947-2IEC 947-26. All doors to have double rubber gasket with shutter assembly & door seating frame.7. The UPS outgoing panels shall have neutral busbars double the size of phase.8. All breaker to have breaker manufacturer's factory made Spreaders.9. In any case Aluminium busbar should not be connected directly to breaker without spreaders.10. The control wiring has to be in appropriate size with MCB protection. 11. Irrespective of the Amp. Capacity all breakers shall be connected to the breakers using busbar only.12. All vertical bus bars in bus bar alley shall have bottem supports.13. All panels shall have top entry only.14. Panel earthing strip should come out vertically on top the panel.15. Earthing bus shall be coated to give a look of tin.16. All indication should be proper colour and with protection of MCB.17. All meters should have protetion of MCB.18. Door earthings shall be provided for all doors.19. Suitable for termination of upto 3 1/2 C x 150 sqmm alrmould cable for each feeder. RAW panel incoming panel : 1 A) Cubicle Details:Material of construction- CRCA-14 SWGIP, Protection- IP-52 as per IS 2147, Indoor cubicle type free standing & floor mounting, front/Rear panels- Hinged doors/ Removeble type , Gland plates-Undriled, dust & vermin proof. Cables entry details:Incoming- All cables are from top Outgoing- All outgoings by cables from top B) Meters: 3 Phase 4 Wire, 440 Volts, Digital meters for Parameters Volt, Amp, Hz, KVA, KW etc, auto scrolling facility, panel mounting on door, suitable for 96 x 96 mm. Range- 0-500V, 10 Amps.DigitalKWH meter with CT's and selector switch. , 415V, 3 Phase, 50 Hz, Aluminium Bus Bar. Bus Bar Supports- FRP. Bus Bar sleeves- Heat shirkable- colour coded.Internal & control wiring- To be with ferrulesHeat resistant type, 1100V grade single core copper flexible. On Quoted rates shall be including all taxes,duties,royalties,lead,lift,transpotation,GST etc complete.Nothing shall be payable separtely. Work shall be executed as per direction of engineer in charge,IISER Pune. Actual installation of MS powder coated encloser with all accessories & provision mentioned above at site shall be measured for payments. Details of compenent of panel is as below :

-

-

-

... More
3.7 KW VFD panel or fan CFM 6000 : MCB 10 A TP 10 Ka C curve, 1 Nos , Contactor , 3 pole, coil 240 V Ac, 9 A power NMX 9, 1 no 3 Nos ,Add on block 2 No+2NC for MNX 9-40 A/MCX 0-12 A 3 Nos Contactor, Auxillary, coil 240 V AC 7.5A, 2 NO+2NC MXO 22 E 1 Nos, Add on block 3 NO + 1 NC Mx-A1 31 E 1 Nos ,Overload replay, 6-10 A , direct mtg 1 Nos Overload relay, direct mtg kit 1 Nos , MCB 6 A SP 10 Ka C curve, 4 Nos Indicating lamp, LED 22 mm dia 240 V Red 1 Nos , Indicating lamp, LED 22 mm dia 240 V Green 1 Nos ,Indicating lamp, LED 22 mm dia 240 V Yellow 1 Nos Push button, flush, Red 1 Nos ,Push button, flush, Green 1 Nos ,Contact Element 1 NO 1 Nos , contact Element 1 NC 1 Nos ,Voltmeter 0-500 V AC, 96 x96 mm MI, CL.1, analog type flush mtg 1 Nos Ammeter 20 A, MI, CTR 5 A, 96x96 mm CL.1 1 Nos ,CT, moulded case, flame retardant 20 A, CTR 5 A, VA 5 , CL :1 3 Nos , Selector switch, 6 A, 2 P, 2 way off rotary 1 Nos ,Control transformer 230/24 V AV, 50 VA 1 Nos Exhaust cooling fan 4" 230 VAC supply 1 Nos , Filter 4 " size 2 Nos ,3.7 KW VFD 440 VAC for HVAV basic VFD 1 Nos ,Selector switch , 20 A, 3P, 2 way, with off rotary for AMM 1 Nos4 sqmm wire FRLS copper PVC insulalted 10 meter 1.5 sqmm wire FRLS copper PVC insulated 30 meter Connectors for wire and cable terminations 12 Nos Speaders for outgoing and incoming MCCB to cable 2 Kg Aluminium busbar size 50 mm x 5 mm Aluminium busbar size 100 mm x 10 mm Aluminium busbar size 30 mm x 5 mm 2 Kg Fabricated panel with 2 mm CRCA sheet , powder coated white shade 2 sqm Mounting fabrication hooks for wall mounting 1 Nos

4

-

-

... More
11 KW VFD with S/D bypass starter : Supply, installation, testing and commissioning of LT panel as per following specifications. Drawing, SLD, GA, BOM & specifications should be submitted to IISER Pune for approval before manufactureing of panel.Supply, installation, testing and commissioning of 3 phase, 4 wire, 415 KV, 0.8 PF, 50 HZ panels. The fabrication shall be made with 14 SWG cold rolled sheet with M/C pressing, powder coated. The surface shall be rigorously treated for derusting in 7 tank process with dephosphating & paintingwith at least 2 coats of approved paint. The panel shall be totally enclosed metal clad type with double gasketting with rubber/ resin lining. The panel shall be having control directory pasted inside the panel. The panel shall be mounted on existing trench/ floor & shall have cable entry provision from the top & bottom with suitable alley as the case may be. The panel shall be tested for the same KA rating of the relevant highhest rating of MCCB. All components shall be from ISO-9001 companies and shall have relevant IS/IES approvals without fail. The panel shall be fully interlocked as required. The panel shall include baseframe channel support. ( The single line daigram shall be closely followed) 1. The panel shall be design as per norms of CEIG/ PWD/ CPWD/ Maharashtra State Electricity Distribution Company Ltd 2. Auxilliary contractor to be provided along with Auto-manual switch where ever required. 3. Ventilators shall be provided for Panels with rated bus bars.4. Al bus earthing shall be provided for all panels.5. Circuit Breakers shall confirm IS 13947-2IEC 947-26. All doors to have double rubber gasket with shutter assembly & door seating frame.7. The UPS outgoing panels shall have neutral busbars double the size of phase.8. All breaker to have breaker manufacturer's factory made Spreaders.9. In any case Aluminium busbar should not be connected directly to breaker without spreaders.10. The control wiring has to be in appropriate size with MCB protection. 11. Irrespective of the Amp. Capacity all breakers shall be connected to the breakers using busbar only.12. All vertical bus bars in bus bar alley shall have bottem supports.13. All panels shall have top entry only.14. Panel earthing strip should come out vertically on top the panel.15. Earthing bus shall be coated to give a look of tin.16. All indication should be proper colour and with protection of MCB.17. All meters should have protetion of MCB.18. Door earthings shall be provided for all doors.19. Suitable for termination of upto 3 1/2 C x 150 sqmm alrmould cable for each feeder. RAW panel incoming panel : 1 A) Cubicle Details:Material of construction- CRCA-14 SWGIP, Protection- IP-52 as per IS 2147, Indoor cubicle type free standing & floor mounting, front/Rear panels- Hinged doors/ Removeble type , Gland plates-Undriled, dust & vermin proof. Cables entry details:Incoming- All cables are from top Outgoing- All outgoings by cables from top B) Meters: 3 Phase 4 Wire, 440 Volts, Digital meters for Parameters Volt, Amp, Hz, KVA, KW etc, auto scrolling facility, panel mounting on door, suitable for 96 x 96 mm. Range- 0-500V, 10 Amps.DigitalKWH meter with CT's and selector switch. , 415V, 3 Phase, 50 Hz, Aluminium Bus Bar. Bus Bar Supports- FRP. Bus Bar sleeves- Heat shirkable- colour coded.Internal & control wiring- To be with ferrulesHeat resistant type, 1100V grade single core copper flexible. On Quoted rates shall be including all taxes,duties,royalties,lead,lift,transpotation,GST etc complete.Nothing shall be payable separtely. Work shall be executed as per direction of engineer in charge,IISER Pune. Actual installation of MS powder coated encloser with all accessories & provision mentioned above at site shall be measured for payments. Details of compenent of panel is as below :

-

-

-

... More
11 KW VFD with S/D bypass starter 1 MCB 63 A TP 10 Ka C curve, 1 Nos 2 Contactor , 3 pole, coil 240 V Ac, 18 A power NMX 18, 1 no 5 Nos 3 Add on block 2 No+2NC for MNX 9-40 A/MCX 0-12 A 3 Nos 4 Contactor, Auxillary, coil 240 V AC 12 A, 3 Nos 5 Add on block 3 NO + 1 NC Mx-A1 31 E 1 Nos 6 Overload replay,9-15 A , direct mtg 1 Nos 7 Overload relay, direct mtg kit 1 Nos 8 MCB 6 A SP 10 Ka C curve, 4 Nos 9 Indicating lamp, LED 22 mm dia 240 V Red 1 Nos 10 Indicating lamp, LED 22 mm dia 240 V Green 1 Nos 11 Indicating lamp, LED 22 mm dia 240 V Yellow 1 Nos 12 Push button, flush, Red 1 Nos 13 Push button, flush, Green 1 Nos 14 Contact Element 1 NO 1 Nos 15 contact Element 1 NC 1 Nos 16 Voltmeter 0-500 V AC, 96 x96 mm MI, CL.1, analog type flush mtg 1 Nos 17 Ammeter 20 A, MI, CTR 5 A, 96x96 mm CL.1 1 Nos 18 CT, moulded case, flame retardant 20 A, CTR 5 A, VA 5 , CL :1 3 Nos 19 Selector switch, 6 A, 2 P, 2 way off rotary 1 Nos 20 Control transformer 230/24 V AV, 50 VA 1 Nos 21 Exhaust cooling fan 4" 230 VAC supply 1 Nos

-

-

-

... More
22 Timer 6-60 sec star delta 240 V supply 2 Nos 23 3.7 KW VFD 440 VAC for HVAV basic VFD 1 Nos 24 Selector switch , 20 A, 3P, 2 way, with off rotary for AMM 1 Nos 25 16 sqmm wire FRLS copper PVC insulalted 10 meter 26 1.5 sqmm wire FRLS copper PVC insulated 30 meter 27 Connectors for wire and cable terminations 12 Nos 28 Speaders for outgoing and incoming MCCB to cable 2 Kg 29 Aluminium busbar size 50 mm x 5 mm 1 Kg 30 Aluminium busbar size 100 mm x 10 mm 1 Kg 31 Aluminium busbar size 30 mm x 5 mm 2 Kg 32 Fabricated panel with 2 mm CRCA sheet , powder coated white shade 3 sqm 33 Mounting fabrication hooks for wall mounting 1 Nos

2

-

-

... More
15 KW VFD with S/D bypass starter : Supply, installation, testing and commissioning of LT panel as per following specifications. Drawing, SLD, GA, BOM & specifications should be submitted to IISER Pune for approval before manufactureing of panel.Supply, installation, testing and commissioning of 3 phase, 4 wire, 415 KV, 0.8 PF, 50 HZ panels. The fabrication shall be made with 14 SWG cold rolled sheet with M/C pressing, powder coated. The surface shall be rigorously treated for derusting in 7 tank process with dephosphating & paintingwith at least 2 coats of approved paint. The panel shall be totally enclosed metal clad type with double gasketting with rubber/ resin lining. The panel shall be having control directory pasted inside the panel. The panel shall be mounted on existing trench/ floor & shall have cable entry provision from the top & bottom with suitable alley as the case may be. The panel shall be tested for the same KA rating of the relevant highhest rating of MCCB. All components shall be from ISO-9001 companies and shall have relevant IS/IES approvals without fail. The panel shall be fully interlocked as required. The panel shall include baseframe channel support. ( The single line daigram shall be closely followed) 1. The panel shall be design as per norms of CEIG/ PWD/ CPWD/ Maharashtra State Electricity Distribution Company Ltd 2. Auxilliary contractor to be provided along with Auto-manual switch where ever required. 3. Ventilators shall be provided for Panels with rated bus bars.4. Al bus earthing shall be provided for all panels.5. Circuit Breakers shall confirm IS 13947-2IEC 947-26. All doors to have double rubber gasket with shutter assembly & door seating frame.7. The UPS outgoing panels shall have neutral busbars double the size of phase.8. All breaker to have breaker manufacturer's factory made Spreaders.9. In any case Aluminium busbar should not be connected directly to breaker without spreaders.10. The control wiring has to be in appropriate size with MCB protection. 11. Irrespective of the Amp. Capacity all breakers shall be connected to the breakers using busbar only.12. All vertical bus bars in bus bar alley shall have bottem supports.13. All panels shall have top entry only.14. Panel earthing strip should come out vertically on top the panel.15. Earthing bus shall be coated to give a look of tin.16. All indication should be proper colour and with protection of MCB.17. All meters should have protetion of MCB.18. Door earthings shall be provided for all doors.19. Suitable for termination of upto 3 1/2 C x 150 sqmm alrmould cable for each feeder. RAW panel incoming panel : 1 A) Cubicle Details:Material of construction- CRCA-14 SWGIP, Protection- IP-52 as per IS 2147, Indoor cubicle type free standing & floor mounting, front/Rear panels- Hinged doors/ Removeble type , Gland plates-Undriled, dust & vermin proof. Cables entry details:Incoming- All cables are from top Outgoing- All outgoings by cables from top B) Meters: 3 Phase 4 Wire, 440 Volts, Digital meters for Parameters Volt, Amp, Hz, KVA, KW etc, auto scrolling facility, panel mounting on door, suitable for 96 x 96 mm. Range- 0-500V, 10 Amps.DigitalKWH meter with CT's and selector switch. , 415V, 3 Phase, 50 Hz, Aluminium Bus Bar. Bus Bar Supports- FRP. Bus Bar sleeves- Heat shirkable- colour coded.Internal & control wiring- To be with ferrulesHeat resistant type, 1100V grade single core copper flexible. On Quoted rates shall be including all taxes,duties,royalties,lead,lift,transpotation,GST etc complete.Nothing shall be payable separtely. Work shall be executed as per direction of engineer in charge,IISER Pune. Actual installation of MS powder coated encloser with all accessories & provision mentioned above at site shall be measured for payments. Details of compenent of panel is as below :

-

-

-

... More
15 KW VFD with S/D bypass starter 1 MCB 63 A TP 10 Ka C curve, 1 Nosxx , 2 Contactor , 3 pole, coil 240 V Ac, 18 A power NMX 18, 1 no 5 Nos 3 Add on block 2 No+2NC for MNX 9-40 A/MCX 0-12 A 3 Nos , 4 Contactor, Auxillary, coil 240 V AC 12 A, 3 Nos 5 Add on block 3 NO + 1 NC Mx-A1 31 E 1 Nos , 6 Overload replay,14-23 A , direct mtg 1 Nos ,7 Overload relay, direct mtg kit 1 Nos , 8 MCB 6 A SP 10 Ka C curve, 4 Nos ,9 Indicating lamp, LED 22 mm dia 240 V Red 1 Nos , 100 Indicating lamp, LED 22 mm dia 240 V Green 1 Nos 11 Indicating lamp, LED 22 mm dia 240 V Yellow 1 Nos 12 Push button, flush, Red 1 No 13 Push button, flush, Green 1 Nos 14 Contact Element 1 NO 1 Nos 15 contact Element 1 NC 1 Nos 16 Voltmeter 0-500 V AC, 96 x96 mm MI, CL.1, analog type flush mtg 1 Nos 17 Ammeter 20 A, MI, CTR 5 A, 96x96 mm CL.1 1 Nos 18 CT, moulded case, flame retardant 20 A, CTR 5 A, VA 5 , CL :1 3 Nos 19 Selector switch, 6 A, 2 P, 2 way off rotary 1 Nos 20 Control transformer 230/24 V AV, 50 VA 1 Nos 21 Exhaust cooling fan 4" 230 VAC supply 1 Nos 22 Timer 6-60 sec star delta 240 V supply 2 No 23 3.7 KW VFD 440 VAC for HVAV basic VFD 1 Nos 24 Selector switch , 20 A, 3P, 2 way, with off rotary for AMM 1 Nos 25 16 sqmm wire FRLS copper PVC insulalted 10 meter 26 1.5 sqmm wire FRLS copper PVC insulated 30 mete 27 Connectors for wire and cable terminations 12 Nos 28 Speaders for outgoing and incoming MCCB to cable 2 Kg 29 Aluminium busbar size 50 mm x 5 mm 1 Kg 30 Aluminium busbar size 100 mm x 10 mm 1 Kg 31 Aluminium busbar size 30 mm x 5 mm 2 Kg 32 Fabricated panel with 2 mm CRCA sheet , powder coated white shade 3 sqm 33 Mounting fabrication hooks for wall mounting 1 Nos

2

-

-

... More
UPS out / In enclouser box for MCCB : Supply, installation, testing and commissioning of LT panel as per following specifications. Drawing, SLD, GA, BOM & specifications should be submitted to IISER Pune for approval before manufactureing of panel.Supply, installation, testing and commissioning of 3 phase, 4 wire, 415 KV, 0.8 PF, 50 HZ panels. The fabrication shall be made with 14 SWG cold rolled sheet with M/C pressing, powder coated. The surface shall be rigorously treated for derusting in 7 tank process with dephosphating & paintingwith at least 2 coats of approved paint. The panel shall be totally enclosed metal clad type with double gasketting with rubber/ resin lining. The panel shall be having control directory pasted inside the panel. The panel shall be mounted on existing trench/ floor & shall have cable entry provision from the top & bottom with suitable alley as the case may be. The panel shall be tested for the same KA rating of the relevant highhest rating of MCCB. All components shall be from ISO-9001 companies and shall have relevant IS/IES approvals without fail. The panel shall be fully interlocked as required. The panel shall include baseframe channel support. ( The single line daigram shall be closely followed) 1. The panel shall be design as per norms of CEIG/ PWD/ CPWD/ Maharashtra State Electricity Distribution Company Ltd 2. Auxilliary contractor to be provided along with Auto-manual switch where ever required. 3. Ventilators shall be provided for Panels with rated bus bars.4. Al bus earthing shall be provided for all panels.5. Circuit Breakers shall confirm IS 13947-2IEC 947-26. All doors to have double rubber gasket with shutter assembly & door seating frame.7. The UPS outgoing panels shall have neutral busbars double the size of phase.8. All breaker to have breaker manufacturer's factory made Spreaders.9. In any case Aluminium busbar should not be connected directly to breaker without spreaders.10. The control wiring has to be in appropriate size with MCB protection. 11. Irrespective of the Amp. Capacity all breakers shall be connected to the breakers using busbar only.12. All vertical bus bars in bus bar alley shall have bottem supports.13. All panels shall have top entry only.14. Panel earthing strip should come out vertically on top the panel.15. Earthing bus shall be coated to give a look of tin.16. All indication should be proper colour and with protection of MCB.17. All meters should have protetion of MCB.18. Door earthings shall be provided for all doors.19. Suitable for termination of upto 3 1/2 C x 150 sqmm alrmould cable for each feeder. RAW panel incoming panel : 1 A) Cubicle Details:Material of construction- CRCA-14 SWGIP, Protection- IP-52 as per IS 2147, Indoor cubicle type free standing & floor mounting, front/Rear panels- Hinged doors/ Removeble type , Gland plates-Undriled, dust & vermin proof. Cables entry details:Incoming- All cables are from top Outgoing- All outgoings by cables from top B) Meters: 3 Phase 4 Wire, 440 Volts, Digital meters for Parameters Volt, Amp, Hz, KVA, KW etc, auto scrolling facility, panel mounting on door, suitable for 96 x 96 mm. Range- 0-500V, 10 Amps.DigitalKWH meter with CT's and selector switch. Range-400 Amps.BUS BAR: 800 A, TPN, 415V, 3 Phase, 50 Hz, Aluminium Bus Bar. Bus Bar Supports- FRP. Bus Bar sleeves- Heat shirkable- colour coded.Internal & control wiring- To be with ferrulesHeat resistant type, 1100V grade single core copper flexible. C) Incomer:MCCB: Quantity- 01 No.Rating- 250 amps- 50 KA. (Legrand/ L&T/ Siemense) Type-MDO Operation - manual No. of Poles- 4 P, Release- OC/ SC/ EF/ ST. Indications- RYB/ Off/ ON/ Trip. Other features-

4

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.