Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.
Food Corporation Of India - FCI Tender
Electrical and Electronics
Eprocure
Opening Date13 Nov 2024
Closing Date25 Nov 2024
Tender Amount₹ 19,58,929
Costs
EMD
₹ 40,000Document Cost
Refer DocumentsTender Fee
Refer Documents
Summary
Sitc Of Silent Type Dg Set Of 125 Kva Capacity At Fsd Wardha. Following Cpcb Norms Iv Plus.
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_FCI_834886_1Tender No
20/EE/2024-25Tender Authority
Food Corporation Of India ViewPurchaser Address
-Website
http://eprocure.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
Alternator: Synchronous alternator,Brushless and single bearing type alternator capable of delivering a minimum 125 KVA (Corresponding to typical site condition ) at 415V 0.8 Power factor 50 Hz, 3 Phase, 1500 RPM The alternator shall be having Screen protected Drip Proof enclosure, brushless, continuous duty, self-excited and self regulated through AVR conforming to IS: 4722/BS 2613 suitable for tropical conditions alongwith suitable size PVC insulated copper conductor interconnection cable in suitable pipe between alternator and AMF control panel
-
-
-
Control panel: Fabricating, Installing, Testing & Commissioing of weather proof outdoor type automatic mains failure control including auto by-pass panel, Suitable for 125 KVA silent type DG set complete with relays, timers, set of CTs for metering & protection and energy analyser to indicate currents, phase and line voltages, frequency, power factor, KWH, KVARH & provision for overload, short circuit resticted, earth fault, under frequency, control cabling from AMF panel to diesel engine and elsewhere if required, all completed and inter locking including the following:
-
-
-
C1) Sutaible No of 4 pole switch Fuse motorised electrically operated draw out with cradle type 3 position ACB with electromagnatic release for O/C & E/F and shunt trip.
-
-
-
C2) Auto off selector switch
-
-
-
C3) 2 Nos over voltage relay, 2Nos reverse power relay and 2 Nos under voltage relay
-
-
-
C4) 3 sets of current transformers 15P 10 accuracy for protection and 15 VA class-I for metering
-
-
-
C5) Energy analyser unit to indicate current volatge frequency power factor and KWH
-
-
-
C6) Indicating lamps for load on mains and load on set
-
-
-
C7) fuse for instruments
-
-
-
C8) Battery charger, complete with transformer/rectifier, DC voltmeter and ammeter, selector switch for tricker, off and boost and current adjustment.
-
-
-
C9) Main supply failure monitor
-
-
-
C10) Supply failure timer
-
-
-
C11) Restoration timer
-
-
-
C12) Control unit with three impulse automatic engine start/stop and failure to start lockout
-
-
-
C13) Impulse counter with locking and reset facility
-
-
-
C14) ON/OFF/Control circuit switch with indicator
-
-
-
C15) Audio/Video annuciation for
-
-
-
i) High water temperature
-
-
-
ii) Low lubricating oil pressure
-
-
-
iii) Engine over speed
-
-
-
iv) Engine fails to start
-
-
-
v) Full load/maximum load warning
-
-
-
ACOUSTIC ENCLOSURE (noise level less than or equal to 75 db at a distance of 1 m from of Acoustic enclosure. )- Weather proof prefabricated factory built, free standing, floor mounting type acoustic encloser of moduler construction suitable for accommodating the 125 KVA Engine Alternator set with standard control/ instrument panel, fuel tank etc with arrangement for fresh air intake for cooling of the engine & alternator, extraction, discharging hot air into the atmosphere as per CPWD specifications.
-
-
-
F.I.T.C.of 125 KVA DG Set -Installation testing and Commissioning of the above 125 KVA DG set with acoustic enclosure and AMF control panel with all equipments, accessories and associated items on the cement concrete floor / foundation (with vibration isolation arrangement) (APCC(1:2:4, M-20 grade) foundation of weight 2.5 times the operating weight of the Genset with enclosure or as recommended by the Genset manufacturer OEM/OEA, whichever is higher. The foundation should be min 300 mm high from the ground level. The length and breath of foundation should be at least 250mm more on all sides than the size of the enclosure)including providing necessary fuel MS piping and conducting Acceptance Testing of the Engine Alternator by arranging necessary consumables like Lube oil,fuel oil ,providing artificial resistive load with cabling ,switching arrangements etc. for Testing. The testing will be done as per the inspection and testing procedure mentioned in the MTF/NIT/Tender documents. The Construction of DG Set's PCC Foundation ( upto depth of 400 mm) and other materials as required for ITC of DG Set shall be in the scope of Seller
-
-
-
Supply of PVC insulated and PVC sheathed XPLE power cable of 1.1 KV grade armoured UG aluminium conductor cable conforming to IS 7098 part 1 with up-to-date amendment of the following size as required.
-
-
-
3.5 x120 sq. mm
40
1690
67600
Supplying and making end termination with brass compression
gland and aluminium lugs for following size of PVC insulated and
PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade
as required
-
-
-
3.5 x 120 sq. mm
2
613
1226
Laying of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of following size directly in ground including excavation ,sand cusioning, protective covering and refillig the trench as required.
-
-
-
Above 95 sqmm and upto 185 sqmm
15
422
6330
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.
-
-
-
Above 95 sqmm and upto 185 sqmm( clamped with 25/40x3 mm MS Flat Clamp)
25
153
3825
EARTHING
-
-
-
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/coke and salt as required.
4
7472
29888
Providing and fixing 25 mm x 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I, nut, bolt, spring, washer excavation and re-filling etc. as required.
20
706
14120
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required
40
244
9760