Directorate Of Technical Education Tender

... More
Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.

Directorate Of Technical Education Tender

Goods
Electrical Goods and Equipments
Electrical and Electronics
Eprocure
Opening Date22 Feb 2025
Closing Soon10 Mar 2025
Tender AmountRefer Documents 
Notes
Download

Costs

  • EMD

    ₹ 1,80,000
  • Document Cost

    ₹ 21,240
  • Tender Fee

    ₹ 500

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
30 kVA without isolation transformer UPS and Battery backup Supply installation and commissioning of UPS 3phase input and 3 phase output rating 30 kVA without isolation transformer 2Level IGBT switching high frequency PWM technology,) IGBT Based rectifier and inverter with double conversion UPS System, with input voltage 320~480VL-L @ full Load & 260 – 480 @ 50% Load and out put voltage 400 Vac +/-1% 3-Phase + N + E Unity power factor CommunicationPorts RS232,Modbus and inbuilt Ups efficiency should be Min 94% SNMP Card system to monitor operation- System With inbuilt phase sequence corrector inbuilt , Transient surge voltage surge suppressor include parallel operation up to 6 units , Ups base frame is required for proper wiring support and to avoid direct floor contact ,this system shall include Parallel kit To operate this system inparallel redundancy mode with battery temperature sensor inbuilt in the system, ups should include Emergency power off kit to shut down ups in Emergency condition , protection- IP 20

1

-

-

... More
Battery backup - Battery should be provided or consider at 0.8 load pf on 100% full load 15 min backup - with Min Guranteed VAh - 17120 VAh -Battery should be SMF VRLA 12 volt - make -Exide /Quanta - battery should be use of 42 Ah Accesories - With battery rack made of metal channel to place supportr respective batteries for corriosion resistance asethetically pupose battery rack should be Powder coated , Dc isolator OR Suitable SFu links shuold be reuired , Ups to battery Standard DC cable should be required , battery interlinks should be at contractor scope - UPS warranty - 3 Years / Battery Warranty - 3 years

1

-

-

... More
30 kVA with Inbuilt isolation transformer UPS and Battery backup Supply installation and commissioning of UPS 3phase input and 3 phase output rating 30 kVA with Inbuilt isolation transformer As per given deatail specification 2Level IGBT switching high frequency PWM technology,) IGBT Based rectifier and inverter with double conversion UPS System, with input voltage 320~480VL-L @ full Load & 260 – 480 @ 50% Load and out put voltage 400 Vac +/-1% 3-Phase + N + E Unity power factor CommunicationPorts RS232,Modbus and inbuilt Ups efficiency should be Min 94% SNMP Card system to monitor operation- System With inbuilt phase sequence corrector inbuilt , Transient surge voltage surge suppressor include parallel operation up to 6 units , Ups base frame is required for proper wiring support and to avoid direct floor contact ,this system shall include Parallel kit To operate this system inparallel redundancy mode , ups should include Emergency power off kit to shut down ups in Emergency condition , protection- IP 20

1

-

-

... More
Battery backup - Battery should be provided or consider at 0.8 load pf on 100% full load 60 min backup - with Min Guranteed VAh - 45600 VAh -Battery should be SMF VRLA 12 volt - make -Exide /Quanta - battery should be use of 100 Ah Accesories - With battery rack made of metal channel to place support respective batteries for corriosion resistance asethetically pupose battery rack should be Powder coated , Dc isolator OR Suitable SFu links shuold be reuired , Ups to battery Standard DC cable should be required , battery interlinks should be at contractor scope - UPS warranty - 3 Years / Battery Warranty - 3 years

1

-

-

... More
40 kVA with Inbuilt isolation transformer UPS and Battery backup Supply installation and commissioning of UPS 3phase input and 3 phase output rating 40 kVA with Inbuilt isolation transformer As per given deatail specification 2Level IGBT switching high frequency PWM technology,) IGBT Based rectifier and inverter with double conversion UPS System, with input voltage 320~480VL-L @ full Load & 260 – 480 @ 50% Load and out put voltage 400 Vac +/-1% 3-Phase + N + E Unity power factor CommunicationPorts RS232,Modbus and inbuilt Ups efficiency should be Min 94% SNMP Card system to monitor operation- System With inbuilt phase sequence corrector inbuilt , Transient surge voltage surge suppressor include parallel operation up to 6 units , Ups base frame is required for proper wiring support and to avoid direct floor contact ,this system shall include Parallel kit To operate this system inparallel redundancy mode, ups should include Emergency power off kit to shut down ups in Emergency condition , protection- IP 20

1

-

-

... More
Battery backup - Battery should be provided or consider at 0.9 load pf on 100% full load 60 min backup - with Min Guranteed VAh - 76800 VAh -Battery should be SMF VRLA 12 volt - make -Exide /Quanta - battery should be use of 100 Ah Accesories - With battery rack made of metal channel to place support respective batteries for corriosion resistance asethetically pupose battery rack should be Powder coated , Dc isolator OR Suitable SFu links shuold be reuired , Ups to battery Standard DC cable should be required , battery interlinks should be at contractor scope - UPS warranty - 3 Years / Battery Warranty - 3 years

1

-

-

... More
40 kVA without isolation transformer UPS and Battery backup Supply installation and commissioning of UPS 3phase input and 3 phase output rating 40 kVA without isolation transformer 2Level IGBT switching high frequency PWM technology,) IGBT Based rectifier and inverter with double conversion UPS System, with input voltage 320~480VL-L @ full Load & 260 – 480 @ 50% Load and out put voltage 400 Vac +/-1% 3-Phase + N + E Unity power factor CommunicationPorts RS232,Modbus and inbuilt Ups efficiency should be Min 94% SNMP Card system to monitor operation- System With inbuilt phase sequence corrector inbuilt , Transient surge voltage surge suppressor include parallel operation up to 6 units , Ups base frame is required for proper wiring support and to avoid direct floor contact ,this system shall include Parallel kit To operate this system inparallel redundancy mode, ups should include Emergency power off kit to shut down ups in Emergency condition , protection- IP 20

3

-

-

... More
Battery backup - Battery should be provided or consider at 0.8 load pf on 100% full load 15 min backup - with Min Guranteed VAh - 20160 VAh -Battery should be SMF VRLA 12 volt - make -Exide /Quanta - battery should be use of 42 Ah Accesories - With battery rack made of metal channel to place support respective batteries for corriosion resistance asethetically pupose battery rack should be Powder coated , Dc isolator OR Suitable SFu links shuold be reuired , Ups to battery Standard DC cable should be required , battery interlinks should be at contractor scope - UPS warranty - 3 Years / Battery Warranty - 3 years

3

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.