Directorate Of Sports And Youth Services Tender
Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.
Directorate Of Sports And Youth Services - DSYSP Tender
Civil And Construction
Eprocure
Opening Date29 Oct 2021
Closing Date10 Nov 2021
Tender Amount₹ 1,19,70,712 This is an estimated amount, exact amount may vary.
Costs
EMD
₹ 1,30,000Document Cost
₹ 1,000Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2021_DSYSP_733461_1Bid Award Id
ViewTender No
AFC/TENDER/06/2021-22/D-11Tender Authority
Directorate Of Sports And Youth Services ViewPurchaser Address
-Website
http://mahatenders.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 mm thick in cement mortar 1:4 using waterproofing compound at 1Kilogramper cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 mm thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc.complete..
Spec.no.:- Bd.L.7 Page Number 369
696.6
-
-
... More
Providing and applying two coats of exterior weather shield paint of approved manufacture and of approved colour to the plastered surfaces including cleaning ,preparing the plaster surface ,applying primer coat ,scaffolding if necessary, and watering the surface for two days etc complete.
NOTE: prior approval of Superintending Engineer will be necessary.
Spec.no.:- As directed by Engineer in charge.
696.6
-
-
... More
3 Meter Height PVC coated Safety Chainlink Fencing (Sports Fencing)
Design, Supply, Installation & testing the factory powder coated Chainlink fencing of 3 meter height and all other required accessories for fixing including all required structural member, vertical post concrete pedestal etc. all complete around the Playing field as per layout drawings, including necessary civil work as per IS code, structural codes all complete and directed by engineer in charge of the projects. Design must be able to resist the impact of football but at the same time chainlink fencing should be resilient enough not to reflect the football impact.
Min. requirement of Chainlink & Structural member as below,
1)Mesh Requirement:- Mesh Size – 50mm X50mm , Inner wire of min. Dia. 2.5 mm made up of Pre-galvanised min. 40GSM. in addition UV resistance PVC coating of min. 1mm thick. (Total OD of Chainlink min. 3.5mm) (Chainlink fencing Height 2.7meter Above Brickwork Plinth).
2)Vertical post must be Min. 88mm outer dia. & 3.2mm thick or equivalent other type of section with equivalant structural properties like MI, Z as per structual design code with required stiffners, Foundation, Anchor bolts & plates. 3)All horizontal Post must be min.60mm outer dia. & 2mm thick or equivalent other type of section with equivalant structural properties like MI, Z as per structual design code. 4)All Suitable line wires, Tie wires, Clamps , Joineries, Aluminium flats, connectors to ensure tight fixation (welding free fixing) as per standard design code & approved by structural consultant.
5)All Structural member & vertical post Foundation sizes designed as per Standard design of IS codes. (Min Grade of RCC concrete Should be M25)
6)All Structural Member must be factory made powder coated in Green colour as per FIFA requirement & consultant approved.
Note:- a) Bidder to submit Shop Dwg & as build dwg for mentioned layout, design calculations & structural stability certificate. before procurement of material on site(all charges of this items in bidder scope).
b) Periphery brickwork wall plinth of 0.3m ht from GL will paid separately.
445
-
-
... More
6 Meter Height PVC coated Safety Chainlink Fencing (Sports Fencing)
Design, Supply, Installation & testing the factory powder coated Chainlink fencing of 6 meter height and all other required accessories for fixing including all required structural member, vertical post concrete pedestal etc. all complete around the Playing field as per layout drawings, including necessary civil work as per IS code, structural codes all complete and directed by engineer in charge of the projects. Design must be able to resist the impact of football but at the same time chainlink fencing should be resilient enough not to reflect the football impact.
Min. requirement of Chainlink & Structural member as below,
1)Mesh Requirement:- Mesh Size – 50mm X50mm , Inner wire of min. Dia. 2.5 mm made up of Pre-galvanised min. 40GSM. in addition UV resistance PVC coating of min. 1mm thick. (Total OD of Chainlink min. 3.5mm) (Chainlink fencing Height 5.7meter Above Brickwork Plinth).
2)Vertical post must be Min. 88mm outer dia. & 3.2mm thick or equivalent other type of section with equivalant structural properties like MI, Z as per structual design code with required stiffners, Foundation, Anchor bolts & plates. 3)All horizontal Post must be min.60mm outer dia. & 2mm thick or equivalent other type of section with equivalant structural properties like MI, Z as per structual design code. 4)All Suitable line wires, Tie wires, Clamps , Joineries, Aluminium flats, connectors to ensure tight fixation (welding free fixing) as per standard design code & approved by structural consultant.
5)All Structural member & vertical post Foundation sizes designed as per Standard design of IS codes. (Min Grade of RCC concrete Should be M25)
6)All Structural Member must be factory made powder coated in Green colour as per FIFA requirement & consultant approved.
Note:- a) Bidder to submit Shop Dwg & as build dwg for mentioned layout, design calculations & structural stability certificate. before procurement of material on site(all charges of this items in bidder scope).
b) Periphery brickwork wall plinth of 0.3m ht from GL will paid separately.
276
-
-
... More
Single Shutter Gate with Chainlink, Opening Size 1.5 m Wide X 3.0M Height.
Design, Supply, Fixing & testing the factory powder coated Chainlink Single Shutter Gate of opening 1.5 meter wide & 3 meter height and all other required accessories for fixing including vertical pole required civil work, including required Heavy duty Doors hardware , fixtures & accessories etc. all complete as per layout drawings, including necessary civil work as per IS code, structural codes all complete and directed by engineer in charge of the projects. Design must be able to resist the impact of football but at the same time chainlink fencing should be resilient enough not to reflect the football impact.
Min. requirement of Chainlink Gate as below,
1)Mesh Requirement:- Mesh Size – 50mm X50mm , Inner wire of min. Dia. 2.5 mm made up of Pre-galvanised min. 40GSM. in addition UV resistance PVC coating of min. 1mm thick. (Total OD of Chainlink min. 3.5mm).
2)All Structural members are powder coated in Green colour as per FIFA requirement & approved by consultant and Sizes of structural member must be designed as per Structural design codes.
3)All Suitable line wires, Tie wires, Clamps , Joineries, Aluminium flats, connectors to ensure tight fixation as per standard design code & approved by structural consultant.
4)All Structural member & vertical post Foundation sizes designed as per Standard design of IS codes. (Min Grade of RCC concrete Should be M25)
Note:- Bidder to submit Shop Dwg & as build dwg for mentioned layout, design calculations & structural stability certificate. (all charges of this items in bidder scope)
6
-
-
... More
Double Shutter Gate with Chainlink, Opening Size 3.0 M Wide X 3.0M Height.
Design, Supply, Fixing & testing the factory powder coated Chainlink Double Shutter Gate of opening 3 meter wide & 3 meter height and all other required accessories for fixing including vertical pole required civil work, including required Heavy duty Doors hardware , fixtures & accessories etc. all complete as per layout drawings, including necessary civil work as per IS code, structural codes all complete and directed by engineer in charge of the projects. Design must be able to resist the impact of football but at the same time chainlink fencing should be resilient enough not to reflect the football impact.
Min. requirement of Chainlink Gate as below,
1)Mesh Requirement:- Mesh Size – 50mm X50mm , Inner wire of min. Dia. 2.5 mm made up of Pre-galvanised min. 40GSM. in addition UV resistance PVC coating of min. 1mm thick. (Total OD of Chainlink min. 3.5mm).
2)All Structural members are powder coated in Green colour as per FIFA requirement & approved by consultant and Sizes of structural member must be designed as per Structural design codes.
3)All Suitable line wires, Tie wires, Clamps , Joineries, Aluminium flats, connectors to ensure tight fixation as per standard design code & approved by structural consultant.
4)All Structural member & vertical post Foundation sizes designed as per Standard design of IS codes. (Min Grade of RCC concrete Should be M25)
Note:- Bidder to submit Shop Dwg & as build dwg for mentioned layout, design calculations & structural stability certificate. (all charges of this items in bidder scope)
2
-
-
... More
Fixed Seating for Main Stadium Providing and fixing double-wall hollow blow mold bucket type seat having minimum dimensions as 500 mm side length x 440 mm front width x 420 mm rear height in one piece of HDPE having minimum shell thickness of 3 mm on each wall and minimum density of 0.95 gram/cm3, weight of plastic chair should not be less than 2.4 kg, chair should withstand in high temperature not less than 50°C with ultraviolet stabilizer and color fastness, having ergonomic design, with two digit aluminum number plate for seat to be fixed on aluminum floor mount frame by the process of grouting with bolt. The chair should be fixed with Metal Inserts moulded inside seat to connect seat with Galvanized pipes 25 Nominal Bore light running under the chairs. The pipes are resting above Aluminum bracket at c/c distance from 1.5 to 1.7 mtr and all open ends of all pipes are to be closed by PVC cap. Water should not accumulate on chair. Chair should have a warranty of 2 years against significant colour fading and 5 year against breakage due to manufacturing. Make: VIP India, Superior, Freewell)
Chair Plastic Part should have been tested with xenon –Arc exposure Test as per ISO 4892-2:2013 ,Cycle-1.
The Grey Sale Rating should be (GSR) : 4,
Delta Δ E : 3
Valid Test Certificate to be submitted
The seat should pass BSEN 12520:2015 TEST
250
-
-
... More
Labour Rate for removing & refitting existing spectator Chair with necessary required fixtures & hardware, as directed by engineer in charge and etc. all complete.
250
-
-
... More
Providing and fixing stainless steel (Grade 304) railing made of hollow tubes, channels, plates, Flat etc. including welding grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories and stainless steel dash fasteners, stainless steel bolts, etc. of the required size on the top of the floor of the side of waiste slab with suitable arrangement as per approval of engineer in charge and as per Dwg (for payment purpose, only the weight of the stainless steel members shall be considered excluding fixing accessories such as nut bolts, fasteners etc.). top pipe should be 50mm dia. pipe, 1.5mm thickness and weight 1.92Kilogram/ running metre.
Spec.no.:- As directed by Engineer-in- charge
1400
-
-
Evaluation Notes How It Works ?