Directorate Of Municipal Administration Tender

Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.

Directorate Of Municipal Administration - DMA Tender

Works
Eprocure
Opening Date7 Jul 2020
Closing Date7 Aug 2020
Tender Amount₹ 6,66,28,594 
This is an estimated amount, exact amount may vary.
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Providing and laying in-situ M-30 Grade unreinforced plain cement concrete pavement over a prepared sub base with 43 grade cement, coarse and fine aggregate( natural sand/ VSI grade finely washed crushed sand) conforming to IS 383, using fine and coarse aggregates combined gradation as per Table 600-3 of MORTH Specification 2013, mixed in a batching and mixing plant/ non tilting mixer and Weigh batcher as per approved mix design, admixtures, transporting to site, spreading, laying with approved make paver, compacted and finished in a continuous operation, finishing to lines and grades as directed by Engineer-in-charge and curing by curing compound /by providing cement vata in cement Mortar 1:8 @0.6 metre X 0.6 metre centre to centre, admeasuring 80 mili metre at bottom and 40 mili metre at top with depth of 75 mili metre and maintaining the same throughout curing period by any other method approved by Engineer-in-charge.

512.1

-

6925.37

... More
Cutting transverse contraction joints 3 to 4 mili metre wide and depth 60 mili metre .in concrete slab using concrete cutting machine with diamond studded saw within 48 hours of casting of bay / slab etcetera complete including subsequent widening of the groove 8 to 10 mili metre wide at top having depth of 15 mili metre as directed by Engineer incharge.

948.33

-

71.68

... More
VQCC Testing Charges

-

-

-

... More
Finness Modulas (Sieve Analysis), Silt Content & Clay Content

3

-

1200

... More
Water Absorption, Specific Gravity, Impact Value, Crushing Value

3

-

2300

... More
Sieve Analysis for Metal

3

-

600

... More
Compressive Strength of Cement Concrete Cube (Set of 3 Cubes)

20

-

600

... More
Royalty Charges

819.36

-

141.34

... More
6% Central Goods Services & Tax + 6% State Goods Services & Tax

4218540

-

0.12

... More
2] Constg. C.C. Road & Drain from Kshirsagar to Jadhav House (Mauli Colony), Ward No.24 @ Beed Tq. Beed

-

-

-

... More
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing to proper grade and camber, applying and brooming requisite type of screening/ binding Materials to fill up the interstices of coarse aggregate, watering and compacting with Vibratory roller. to the required density. By Mechanical Means - Grading I (Using Screening Type A (13.2) mili metre Aggregate)

176.25

-

2082.18

... More
Providing and laying 125 micron Low Density Polyethylene (LDPE) sheet Confirming to Indian Standard 3395 : 1997 below concrete pavement including all materials and labour complete.

2350

-

20.78

... More
Providing and laying in-situ M-30 Grade unreinforced plain cement concrete pavement over a prepared sub base with 43 grade cement, coarse and fine aggregate( natural sand/ VSI grade finely washed crushed sand) conforming to IS 383, using fine and coarse aggregates combined gradation as per Table 600-3 of MORTH Specification 2013, mixed in a batching and mixing plant/ non tilting mixer and Weigh batcher as per approved mix design, admixtures, transporting to site, spreading, laying with approved make paver, compacted and finished in a continuous operation, finishing to lines and grades as directed by Engineer-in-charge and curing by curing compound /by providing cement vata in cement Mortar 1:8 @0.6 metre X 0.6 metre centre to centre, admeasuring 80 mili metre at bottom and 40 mili metre at top with depth of 75 mili metre and maintaining the same throughout curing period by any other method approved by Engineer-in-charge.

352.5

-

6925.37

... More
Excavation for catch / side water gutter in all sorts of soils to the specified section including stacking the excavated stuff in a regular bund and disposing of unsuitable or excess stuff as directed all sorts of soils.

363.78

-

75.86

... More
Construction of granular sub-base by providing close graded Material, mixing in a mechanical mix plant at Optimum Moisture Content, carriage of mixed Material to work site, spreading in uniform layers with motor grader/ Paver on prepared surface and compacting with vibratory roller to achieve the desired density, complete as per clause 401 -- Plant Mix Method and Grading - I Material

60.63

-

2048.95

... More
Providing and laying Cast in situ/Ready Mix cement concrete in M-15 of trap/ granite/quartzite/gneiss metal for bed blocks, foundation blocks and such other items including bailing out water, Steel centering, formwork, laying/ pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etcetera complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etcetera (Wooden centering will not be allowed.), with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etcetera complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etcetera)

173.43

-

6093.3

... More
Cutting transverse contraction joints 3 to 4 mili metre wide and depth 60 mili metre .in concrete slab using concrete cutting machine with diamond studded saw within 48 hours of casting of bay / slab etcetera complete including subsequent widening of the groove 8 to 10 mili metre wide at top having depth of 15 mili metre as directed by Engineer incharge.

783.33

-

71.68

... More
VQCC Testing Charges

-

-

-

... More
Finness Modulas (Sieve Analysis), Silt Content & Clay Content

3

-

1200

... More
Water Absorption, Specific Gravity, Impact Value, Crushing Value

3

-

2300

... More
Sieve Analysis for Metal

2

-

600

... More
Compressive Strength of Cement Concrete Cube (Set of 3 Cubes)

20

-

600

... More
Royalty Charges

638.91

-

141.34

... More
6% Central Goods Services & Tax + 6% State Goods Services & Tax

4121742

-

0.12

... More
3] Constg. C.C. Road & Drain from Kaldhone House to Aaglave House, Pardeshi House to Jadhav House (Sahyadri Garage, Ekta Nagar), Ward No.24 @ Beed Tq. Beed

-

-

-

... More
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing to proper grade and camber, applying and brooming requisite type of screening/ binding Materials to fill up the interstices of coarse aggregate, watering and compacting with Vibratory roller. to the required density. By Mechanical Means - Grading I (Using Screening Type A (13.2) mili metre Aggregate)

27

-

2082.18

... More
Providing and laying 125 micron Low Density Polyethylene (LDPE) sheet Confirming to Indian Standard 3395 : 1997 below concrete pavement including all materials and labour complete.

360

-

20.78

... More
Providing and laying in-situ M-30 Grade unreinforced plain cement concrete pavement over a prepared sub base with 43 grade cement, coarse and fine aggregate( natural sand/ VSI grade finely washed crushed sand) conforming to IS 383, using fine and coarse aggregates combined gradation as per Table 600-3 of MORTH Specification 2013, mixed in a batching and mixing plant/ non tilting mixer and Weigh batcher as per approved mix design, admixtures, transporting to site, spreading, laying with approved make paver, compacted and finished in a continuous operation, finishing to lines and grades as directed by Engineer-in-charge and curing by curing compound /by providing cement vata in cement Mortar 1:8 @0.6 metre X 0.6 metre centre to centre, admeasuring 80 mili metre at bottom and 40 mili metre at top with depth of 75 mili metre and maintaining the same throughout curing period by any other method approved by Engineer-in-charge.

54

-

6925.37

... More
Cutting transverse contraction joints 3 to 4 mili metre wide and depth 60 mili metre .in concrete slab using concrete cutting machine with diamond studded saw within 48 hours of casting of bay / slab etcetera complete including subsequent widening of the groove 8 to 10 mili metre wide at top having depth of 15 mili metre as directed by Engineer incharge.

200

-

71.68

... More
Excavation for catch / side water gutter in all sorts of soils to the specified section including stacking the excavated stuff in a regular bund and disposing of unsuitable or excess stuff as directed all sorts of soils.

92.88

-

75.86

... More
Construction of granular sub-base by providing close graded Material, mixing in a mechanical mix plant at Optimum Moisture Content, carriage of mixed Material to work site, spreading in uniform layers with motor grader/ Paver on prepared surface and compacting with vibratory roller to achieve the desired density, complete as per clause 401 -- Plant Mix Method and Grading - I Material

15.48

-

2048.95

... More
Providing and laying Cast in situ/Ready Mix cement concrete in M-15 of trap/ granite/quartzite/gneiss metal for bed blocks, foundation blocks and such other items including bailing out water, Steel centering, formwork, laying/ pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etcetera complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etcetera (Wooden centering will not be allowed.), with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etcetera complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etcetera)

44.28

-

6093.3

... More
VQCC Testing Charges

-

-

-

... More
Finness Modulas (Sieve Analysis), Silt Content & Clay Content

3

-

1200

... More
Water Absorption, Specific Gravity, Impact Value, Crushing Value

3

-

2300

... More
Sieve Analysis for Metal

1

-

600

... More
Compressive Strength of Cement Concrete Cube (Set of 3 Cubes)

20

-

600

... More
Royalty Charges

106.42

-

141.34

... More
6% Central Goods Services & Tax + 6% State Goods Services & Tax

760580

-

0.12

... More
4] Constg. C.C. Road & Drain from Charata Road to Shaikh Atiq House, Ward No.13 @ Beed Tq. Beed

-

-

-

... More
Providing and laying 125 micron Low Density Polyethylene (LDPE) sheet Confirming to Indian Standard 3395 : 1997 below concrete pavement including all materials and labour complete.

400

-

20.78

... More
Providing and laying in-situ M-30 Grade unreinforced plain cement concrete pavement over a prepared sub base with 43 grade cement, coarse and fine aggregate( natural sand/ VSI grade finely washed crushed sand) conforming to IS 383, using fine and coarse aggregates combined gradation as per Table 600-3 of MORTH Specification 2013, mixed in a batching and mixing plant/ non tilting mixer and Weigh batcher as per approved mix design, admixtures, transporting to site, spreading, laying with approved make paver, compacted and finished in a continuous operation, finishing to lines and grades as directed by Engineer-in-charge and curing by curing compound /by providing cement vata in cement Mortar 1:8 @0.6 metre X 0.6 metre centre to centre, admeasuring 80 mili metre at bottom and 40 mili metre at top with depth of 75 mili metre and maintaining the same throughout curing period by any other method approved by Engineer-in-charge.

60

-

6925.37

... More
Cutting transverse contraction joints 3 to 4 mili metre wide and depth 60 mili metre .in concrete slab using concrete cutting machine with diamond studded saw within 48 hours of casting of bay / slab etcetera complete including subsequent widening of the groove 8 to 10 mili metre wide at top having depth of 15 mili metre as directed by Engineer incharge.

133.33

-

71.68

... More
Excavation for catch / side water gutter in all sorts of soils to the specified section including stacking the excavated stuff in a regular bund and disposing of unsuitable or excess stuff as directed all sorts of soils.

61.92

-

75.86

... More
Construction of granular sub-base by providing close graded Material, mixing in a mechanical mix plant at Optimum Moisture Content, carriage of mixed Material to work site, spreading in uniform layers with motor grader/ Paver on prepared surface and compacting with vibratory roller to achieve the desired density, complete as per clause 401 -- Plant Mix Method and Grading - I Material

10.32

-

2048.95

... More
Providing and laying Cast in situ/Ready Mix cement concrete in M-15 of trap/ granite/quartzite/gneiss metal for bed blocks, foundation blocks and such other items including bailing out water, Steel centering, formwork, laying/ pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etcetera complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etcetera (Wooden centering will not be allowed.), with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etcetera complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etcetera)

29.52

-

6093.3

... More
VQCC Testing Charges

-

-

-

... More
Finness Modulas (Sieve Analysis), Silt Content & Clay Content

3

-

1200

... More
Water Absorption, Specific Gravity, Impact Value, Crushing Value

3

-

2300

... More
Compressive Strength of Cement Concrete Cube (Set of 3 Cubes)

20

-

600

... More
Royalty Charges

73.45

-

141.34

... More
6% Central Goods Services & Tax + 6% State Goods Services & Tax

639107

-

0.12

... More
5] Constg. C.C. Road & Drain from Sasane to Survase, Bashed Shaikh to Atik, Ankush Nagar to Shaikh, Pani Taki to Sattar (Pani Taki to Dhanora Road) Raju Nagar, Ward No.13 @ Beed Tq. Beed

-

-

-

... More
Providing and laying 125 micron Low Density Polyethylene (LDPE) sheet Confirming to Indian Standard 3395 : 1997 below concrete pavement including all materials and labour complete.

750

-

20.78

... More
Providing and laying in-situ M-30 Grade unreinforced plain cement concrete pavement over a prepared sub base with 43 grade cement, coarse and fine aggregate( natural sand/ VSI grade finely washed crushed sand) conforming to IS 383, using fine and coarse aggregates combined gradation as per Table 600-3 of MORTH Specification 2013, mixed in a batching and mixing plant/ non tilting mixer and Weigh batcher as per approved mix design, admixtures, transporting to site, spreading, laying with approved make paver, compacted and finished in a continuous operation, finishing to lines and grades as directed by Engineer-in-charge and curing by curing compound /by providing cement vata in cement Mortar 1:8 @0.6 metre X 0.6 metre centre to centre, admeasuring 80 mili metre at bottom and 40 mili metre at top with depth of 75 mili metre and maintaining the same throughout curing period by any other method approved by Engineer-in-charge.

112.5

-

6925.37

... More
Cutting transverse contraction joints 3 to 4 mili metre wide and depth 60 mili metre .in concrete slab using concrete cutting machine with diamond studded saw within 48 hours of casting of bay / slab etcetera complete including subsequent widening of the groove 8 to 10 mili metre wide at top having depth of 15 mili metre as directed by Engineer incharge.

250

-

71.68

... More
Excavation for catch / side water gutter in all sorts of soils to the specified section including stacking the excavated stuff in a regular bund and disposing of unsuitable or excess stuff as directed all sorts of soils.

116.1

-

75.86

... More
Construction of granular sub-base by providing close graded Material, mixing in a mechanical mix plant at Optimum Moisture Content, carriage of mixed Material to work site, spreading in uniform layers with motor grader/ Paver on prepared surface and compacting with vibratory roller to achieve the desired density, complete as per clause 401 -- Plant Mix Method and Grading - I Material

19.35

-

2048.95

... More
Providing and laying Cast in situ/Ready Mix cement concrete in M-15 of trap/ granite/quartzite/gneiss metal for bed blocks, foundation blocks and such other items including bailing out water, Steel centering, formwork, laying/ pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etcetera complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etcetera (Wooden centering will not be allowed.), with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etcetera complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etcetera)

55.35

-

6093.3

... More
VQCC Testing Charges

-

-

-

... More
Finness Modulas (Sieve Analysis), Silt Content & Clay Content

3

-

1200

... More
Water Absorption, Specific Gravity, Impact Value, Crushing Value

3

-

2300

... More
Compressive Strength of Cement Concrete Cube (Set of 3 Cubes)

20

-

600

... More
Royalty Charges

136.66

-

141.34

... More
6% Central Goods Services & Tax + 6% State Goods Services & Tax

1198327

-

0.12

... More
6] Construction of Retaining Wall at Karpara River at Sambhaji Nagar @ Beed Tq. Beed

-

-

-

... More
Excavation for foundation in hard rock by chiselling and wedging or line drilling including shoring and strutting, dewatering as necessary and disposing off excavated stuff as directed etcetera complete. a) Upto 1.50 metre lift Normal Rate

18.72

-

1471.51

... More
Providing and fixing 25 mili metre diameter steel anchor dowel in hard rock including drilling hole of 32 mili metre diametre up to 0.75 Metres depth, placing the dowel in position and effectively grouting the hole with centi mortor 1:1 proportion etcetera complete.

53

-

1255

... More
Providing and laying in situ / ready mix controlled grade of M-25 of trap /granite /quartzite /gneiss metal for Reinforced Cement Concrete works in cut off walls / curtain walls including necessary scaffolding, centering, compacting by vibrator, finishing and curing etcetera complete. (with fully automatic micro processor based PLC with SCADA enabled with reversible drum type mixer/ concrete batch mix plant (pan mixer) with fine aggregates of required specifications (Natural sand / VSI sand finely washed etcetera ), excluding reinforcement)

146.84

-

7039.04

... More
Providing, cutting, bending, hooking, tying and laying in position Thermo Mechanical Treated (TMT) FE 500 steel bars for reinforcement for all Reinforced Cement Concrete works as per detailed drawings etcetera complete.

5.87

-

65592.23

... More
Back filling behind abutment, wing wall and return wall as per drawings and technical specifications etcetera complete. (by granular material)

156

-

1070.4

... More
Providing and laying weep holes of 100 mili metre diametre Polyvenyle Chloride pipes as per drawing for abutment returns, return walls etcetera Complete.

31.2

-

440.62

... More
Providing and laying pitching on slopes laid over prepared filter media including boulder apron laid dry in front of toe of embankment complete as per drawing and technical specifications etcetera complete. (by stone/boulder)

31.2

-

1707

... More
VQCC Testing Charges

-

-

-

... More
Finness Modulas (Sieve Analysis), Silt Content & Clay Content

1

-

1200

... More
Water Absorption, Specific Gravity, Impact Value, Crushing Value

1

-

2300

... More
Sieve Analysis for Metal

1

-

600

... More
Compressive Strength of Cement Concrete Cube (Set of 3 Cubes)

15

-

600

... More
Royalty Charges

374.41

-

141.34

... More
6% Central Goods Services & Tax + 6% State Goods Services & Tax

1746849

-

0.12

... More
7] Construction of B.T. Road from Rest House to Mane Complex @ Beed Tq. Beed

-

-

-

... More
Construction of granular sub-base by providing close graded Material, mixing in a mechanical mix plant at Optimum Moisture Content, carriage of mixed Material to work site, spreading in uniform layers with motor grader / Paver on prepared surface and compacting with vibratory roller to achieve the desired density, complete as per clause 401 -- Plant Mix Method and Grading - II Material

300

-

2420.51

... More
Providing and constructing 75 mili metre thick Modified Penetration Macadam (MPM) road surface including all materials, preparing the existing road surface, spreading 40 mili metre stone metal layers 30% crusher broken metal + 70% Hand broken (by breaking rubble obtained by blasting) heating and spraying the bitumen of specified grade @ 2 Kilogram/Square Metre, spreading 12 mili metre size chips compacting with three wheel static roller having weight 8 to 10 Metric Tonne. to achieve the desired degree of compaction as per Technical Specification Clause 506 etcetera complete. Including picking of existing Water Bound Macadam surface. (VG-30 bulk bitumen rates are considered to arrive at rates)

3000

-

270.95

... More
Providing and constructing 50 mili metre thick Modified Penetration Macadam (MPM) road surface including all materials, preparing the existing road surface, spreading 40 mili metre stone layers metal 30% crusher broken metal + 70% Hand broken metal (By breaking Rubble obtained by blasting), heating and spraying the bitumen of specified grade @ 1.75 Kilogram / Square Metre, spreading 12 mili metre size chips compacting with Static roller having weight 8 to 10 Metric Tonne. to achieve the desired degree of compaction as per Technical Specification Clause 506 etcetera complete, including applying tack coat of bitumen of specified grade at the rate of 0.30 Kilogram Square metre(on existing bitumen surface.)

3000

-

201.59

... More
Open Graded Premix Surfacing- Providing and Laying Open Graded Carpet 20 mili metre thickness composed of 13.2 mili metre to 5.6 mili metre aggregates premixed with bituminous binder transported to site with Vehicle Tracking System (VTS), laid over a previously prepared surface, finished to the required grade, level, alignment, and rolling to achieve the desired compaction but excluding prime / tack and Seal coat. For Bitumen of specified grade--USING drum mix type hot mix plant with SCADA, Paver and Vibratory roller ( Over MPM Surface) (VG-30 bulk bitumen rates are considered to arrive at rates)

3000

-

140.1

... More
Providing bituminous Type A liquid seal coat on bituminous surface including supplying all materials and bitumen of specified grade preparing existing road surface, heating and applying bitumen @ 0.98 Kilogram/Square metre by mechanical means, spreading chips and rolling, by static roller having weight 8 to 10 Metric Tonne. etcetera complete. (VG-30 bulk bitumen rates are considered to arrive at rates)

3000

-

56.45

... More
Providing and applying tack coat on the prepared surface heating by fames in Boiler and spraying bitumen with sprayer on Dry / Hungry Black Topped surface 3 Kilogram/10 Square metre (VG-30 bulk bitumen rates are considered to arrive at rates)

3000

-

14.39

... More
6% Central Goods Services & Tax + 6% State Goods Services & Tax

2776568

-

0.12

... More
8] Constg. of C.C. Road & Drain from Mayur Kirana to Kulkarni House (Bhagwan School to Gujar Colony), Ward No.24 @ Beed Tq. Beed

-

-

-

... More
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing to proper grade and camber, applying and brooming requisite type of screening/ binding Materials to fill up the interstices of coarse aggregate, watering and compacting with Vibratory roller. to the required density. By Mechanical Means - Grading I (Using Screening Type A (13.2) mili metre Aggregate)

225

-

2082.18

... More
Providing and laying 125 micron Low Density Polyethylene (LDPE) sheet Confirming to Indian Standard 3395 : 1997 below concrete pavement including all materials and labour complete.

3000

-

20.78

... More
Providing and laying in-situ M-30 Grade unreinforced plain cement concrete pavement over a prepared sub base with 43 grade cement, coarse and fine aggregate( natural sand/ VSI grade finely washed crushed sand) conforming to IS 383, using fine and coarse aggregates combined gradation as per Table 600-3 of MORTH Specification 2013, mixed in a batching and mixing plant/ non tilting mixer and Weigh batcher as per approved mix design, admixtures, transporting to site, spreading, laying with approved make paver, compacted and finished in a continuous operation, finishing to lines and grades as directed by Engineer-in-charge and curing by curing compound /by providing cement vata in cement Mortar 1:8 @0.6 metre X 0.6 metre centre to centre, admeasuring 80 mili metre at bottom and 40 mili metre at top with depth of 75 mili metre and maintaining the same throughout curing period by any other method approved by Engineer-in-charge.

450

-

6925.37

... More
Cutting transverse contraction joints 3 to 4 mili metre wide and depth 60 mili metre .in concrete slab using concrete cutting machine with diamond studded saw within 48 hours of casting of bay / slab etcetera complete including subsequent widening of the groove 8 to 10 mili metre wide at top having depth of 15 mili metre as directed by Engineer incharge.

625

-

71.68

... More
Excavation for catch / side water gutter in all sorts of soils to the specified section including stacking the excavated stuff in a regular bund and disposing of unsuitable or excess stuff as directed all sorts of soils.

290.25

-

75.86

... More
Construction of granular sub-base by providing close graded Material, mixing in a mechanical mix plant at Optimum Moisture Content, carriage of mixed Material to work site, spreading in uniform layers with motor grader/ Paver on prepared surface and compacting with vibratory roller to achieve the desired density, complete as per clause 401 -- Plant Mix Method and Grading - I Material

48.38

-

2048.95

... More
Providing and laying Cast in situ/Ready Mix cement concrete in M-15 of trap/ granite/quartzite/gneiss metal for bed blocks, foundation blocks and such other items including bailing out water, Steel centering, formwork, laying/ pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etcetera complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etcetera (Wooden centering will not be allowed.), with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etcetera complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etcetera)

138.38

-

6093.3

... More
VQCC Testing Charges

-

-

-

... More
Finness Modulas (Sieve Analysis), Silt Content & Clay Content

3

-

1200

... More
Water Absorption, Specific Gravity, Impact Value, Crushing Value

3

-

2300

... More
Sieve Analysis for Metal

3

-

600

... More
Compressive Strength of Cement Concrete Cube (Set of 3 Cubes)

20

-

600

... More
Royalty Charges

780.01

-

141.34

... More
6% Central Goods Services & Tax + 6% State Goods Services & Tax

4656373

-

0.12

... More
9] Constg. of C.C. Road & Drain from Sudhir Survase to More (Nagad Narayan Colony), Ward No.24 @ Beed Tq. Beed

-

-

-

... More
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing to proper grade and camber, applying and brooming requisite type of screening/ binding Materials to fill up the interstices of coarse aggregate, watering and compacting with Vibratory roller. to the required density. By Mechanical Means - Grading I (Using Screening Type A (13.2) mili metre Aggregate)

27

-

2082.18

... More
Providing and laying 125 micron Low Density Polyethylene (LDPE) sheet Confirming to Indian Standard 3395 : 1997 below concrete pavement including all materials and labour complete.

360

-

20.78

... More
Providing and laying in-situ M-30 Grade unreinforced plain cement concrete pavement over a prepared sub base with 43 grade cement, coarse and fine aggregate( natural sand/ VSI grade finely washed crushed sand) conforming to IS 383, using fine and coarse aggregates combined gradation as per Table 600-3 of MORTH Specification 2013, mixed in a batching and mixing plant/ non tilting mixer and Weigh batcher as per approved mix design, admixtures, transporting to site, spreading, laying with approved make paver, compacted and finished in a continuous operation, finishing to lines and grades as directed by Engineer-in-charge and curing by curing compound /by providing cement vata in cement Mortar 1:8 @0.6 metre X 0.6 metre centre to centre, admeasuring 80 mili metre at bottom and 40 mili metre at top with depth of 75 mili metre and maintaining the same throughout curing period by any other method approved by Engineer-in-charge.

54

-

6925.37

... More
Cutting transverse contraction joints 3 to 4 mili metre wide and depth 60 mili metre .in concrete slab using concrete cutting machine with diamond studded saw within 48 hours of casting of bay / slab etcetera complete including subsequent widening of the groove 8 to 10 mili metre wide at top having depth of 15 mili metre as directed by Engineer incharge.

200

-

71.68

... More
Excavation for catch / side water gutter in all sorts of soils to the specified section including stacking the excavated stuff in a regular bund and disposing of unsuitable or excess stuff as directed all sorts of soils.

92.88

-

75.86

... More
Construction of granular sub-base by providing close graded Material, mixing in a mechanical mix plant at Optimum Moisture Content, carriage of mixed Material to work site, spreading in uniform layers with motor grader/ Paver on prepared surface and compacting with vibratory roller to achieve the desired density, complete as per clause 401 -- Plant Mix Method and Grading - I Material

15.48

-

2048.95

... More
Providing and laying Cast in situ/Ready Mix cement concrete in M-15 of trap/ granite/quartzite/gneiss metal for bed blocks, foundation blocks and such other items including bailing out water, Steel centering, formwork, laying/ pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etcetera complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etcetera (Wooden centering will not be allowed.), with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etcetera complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etcetera)

44.28

-

6093.3

... More
VQCC Testing Charges

-

-

-

... More
Finness Modulas (Sieve Analysis), Silt Content & Clay Content

3

-

1200

... More
Water Absorption, Specific Gravity, Impact Value, Crushing Value

3

-

2300

... More
Sieve Analysis for Metal

1

-

600

... More
Compressive Strength of Cement Concrete Cube (Set of 3 Cubes)

20

-

600

... More
Royalty Charges

106.42

-

141.34

... More
6% Central Goods Services & Tax + 6% State Goods Services & Tax

760580

-

0.12

... More
10] Constg. of C.C. Road & Drain from Khokne House to More House, Ward No.03 @ Beed Tq. Beed

-

-

-

... More
Providing and laying 125 micron Low Density Polyethylene (LDPE) sheet Confirming to Indian Standard 3395 : 1997 below concrete pavement including all materials and labour complete.

500

-

20.78

... More
Providing and laying in-situ M-30 Grade unreinforced plain cement concrete pavement over a prepared sub base with 43 grade cement, coarse and fine aggregate( natural sand/ VSI grade finely washed crushed sand) conforming to IS 383, using fine and coarse aggregates combined gradation as per Table 600-3 of MORTH Specification 2013, mixed in a batching and mixing plant/ non tilting mixer and Weigh batcher as per approved mix design, admixtures, transporting to site, spreading, laying with approved make paver, compacted and finished in a continuous operation, finishing to lines and grades as directed by Engineer-in-charge and curing by curing compound /by providing cement vata in cement Mortar 1:8 @0.6 metre X 0.6 metre centre to centre, admeasuring 80 mili metre at bottom and 40 mili metre at top with depth of 75 mili metre and maintaining the same throughout curing period by any other method approved by Engineer-in-charge.

75

-

6925.37

... More
Cutting transverse contraction joints 3 to 4 mili metre wide and depth 60 mili metre .in concrete slab using concrete cutting machine with diamond studded saw within 48 hours of casting of bay / slab etcetera complete including subsequent widening of the groove 8 to 10 mili metre wide at top having depth of 15 mili metre as directed by Engineer incharge.

166.67

-

71.68

... More
Excavation for catch / side water gutter in all sorts of soils to the specified section including stacking the excavated stuff in a regular bund and disposing of unsuitable or excess stuff as directed all sorts of soils.

77.4

-

75.86

... More
Construction of granular sub-base by providing close graded Material, mixing in a mechanical mix plant at Optimum Moisture Content, carriage of mixed Material to work site, spreading in uniform layers with motor grader/ Paver on prepared surface and compacting with vibratory roller to achieve the desired density, complete as per clause 401 -- Plant Mix Method and Grading - I Material

12.9

-

2048.95

... More
Providing and laying Cast in situ/Ready Mix cement concrete in M-15 of trap/ granite/quartzite/gneiss metal for bed blocks, foundation blocks and such other items including bailing out water, Steel centering, formwork, laying/ pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etcetera complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etcetera (Wooden centering will not be allowed.), with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etcetera complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etcetera)

36.9

-

6093.3

... More
VQCC Testing Charges

-

-

-

... More
Finness Modulas (Sieve Analysis), Silt Content & Clay Content

3

-

1200

... More
Water Absorption, Specific Gravity, Impact Value, Crushing Value

3

-

2300

... More
Compressive Strength of Cement Concrete Cube (Set of 3 Cubes)

20

-

600

... More
Royalty Charges

91.51

-

141.34

... More
6% Central Goods Services & Tax + 6% State Goods Services & Tax

798885

-

0.12

... More
11] Constg. of C.C. Road & Drain from Wasant Kulkarni to Prarkar House, Ward No.03 @ Beed Tq. Beed

-

-

-

... More
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing to proper grade and camber, applying and brooming requisite type of screening/ binding Materials to fill up the interstices of coarse aggregate, watering and compacting with Vibratory roller. to the required density. By Mechanical Means - Grading I (Using Screening Type A (13.2) mili metre Aggregate)

15

-

2082.18

... More
Providing and laying 125 micron Low Density Polyethylene (LDPE) sheet Confirming to Indian Standard 3395 : 1997 below concrete pavement including all materials and labour complete.

200

-

20.78

... More
Providing and laying in-situ M-30 Grade unreinforced plain cement concrete pavement over a prepared sub base with 43 grade cement, coarse and fine aggregate( natural sand/ VSI grade finely washed crushed sand) conforming to IS 383, using fine and coarse aggregates combined gradation as per Table 600-3 of MORTH Specification 2013, mixed in a batching and mixing plant/ non tilting mixer and Weigh batcher as per approved mix design, admixtures, transporting to site, spreading, laying with approved make paver, compacted and finished in a continuous operation, finishing to lines and grades as directed by Engineer-in-charge and curing by curing compound /by providing cement vata in cement Mortar 1:8 @0.6 metre X 0.6 metre centre to centre, admeasuring 80 mili metre at bottom and 40 mili metre at top with depth of 75 mili metre and maintaining the same throughout curing period by any other method approved by Engineer-in-charge.

30

-

6925.37

... More
Excavation for catch / side water gutter in all sorts of soils to the specified section including stacking the excavated stuff in a regular bund and disposing of unsuitable or excess stuff as directed all sorts of soils.

38.7

-

75.86

... More
Construction of granular sub-base by providing close graded Material, mixing in a mechanical mix plant at Optimum Moisture Content, carriage of mixed Material to work site, spreading in uniform layers with motor grader/ Paver on prepared surface and compacting with vibratory roller to achieve the desired density, complete as per clause 401 -- Plant Mix Method and Grading - I Material

6.45

-

2048.95

... More
Providing and laying Cast in situ/Ready Mix cement concrete in M-15 of trap/ granite/quartzite/gneiss metal for bed blocks, foundation blocks and such other items including bailing out water, Steel centering, formwork, laying/ pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etcetera complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etcetera (Wooden centering will not be allowed.), with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etcetera complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etcetera)

18.45

-

6093.3

... More
Cutting transverse contraction joints 3 to 4 mili metre wide and depth 60 mili metre .in concrete slab using concrete cutting machine with diamond studded saw within 48 hours of casting of bay / slab etcetera complete including subsequent widening of the groove 8 to 10 mili metre wide at top having depth of 15 mili metre as directed by Engineer incharge.

83.33

-

71.68

... More
VQCC Testing Charges

-

-

-

... More
Finness Modulas (Sieve Analysis), Silt Content & Clay Content

3

-

1200

... More
Water Absorption, Specific Gravity, Impact Value, Crushing Value

3

-

2300

... More
Sieve Analysis for Metal

1

-

600

... More
Compressive Strength of Cement Concrete Cube (Set of 3 Cubes)

20

-

600

... More
Royalty Charges

57.04

-

141.34

... More
6% Central Goods Services & Tax + 6% State Goods Services & Tax

377696

-

0.12

... More
12] Constg. of C.C. Road & Drain from Ramesh Londhe to Ram Tambe (Ram Tirth), Ward No.03 @ Beed Tq. Beed

-

-

-

... More
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing to proper grade and camber, applying and brooming requisite type of screening/ binding Materials to fill up the interstices of coarse aggregate, watering and compacting with Vibratory roller. to the required density. By Mechanical Means - Grading I (Using Screening Type A (13.2) mili metre Aggregate)

36.75

-

2082.18

... More
Providing and laying 125 micron Low Density Polyethylene (LDPE) sheet Confirming to Indian Standard 3395 : 1997 below concrete pavement including all materials and labour complete.

490

-

20.78

... More
Providing and laying in-situ M-30 Grade unreinforced plain cement concrete pavement over a prepared sub base with 43 grade cement, coarse and fine aggregate( natural sand/ VSI grade finely washed crushed sand) conforming to IS 383, using fine and coarse aggregates combined gradation as per Table 600-3 of MORTH Specification 2013, mixed in a batching and mixing plant/ non tilting mixer and Weigh batcher as per approved mix design, admixtures, transporting to site, spreading, laying with approved make paver, compacted and finished in a continuous operation, finishing to lines and grades as directed by Engineer-in-charge and curing by curing compound /by providing cement vata in cement Mortar 1:8 @0.6 metre X 0.6 metre centre to centre, admeasuring 80 mili metre at bottom and 40 mili metre at top with depth of 75 mili metre and maintaining the same throughout curing period by any other method approved by Engineer-in-charge.

73.5

-

6925.37

... More
Excavation for catch / side water gutter in all sorts of soils to the specified section including stacking the excavated stuff in a regular bund and disposing of unsuitable or excess stuff as directed all sorts of soils.

61.92

-

75.86

... More
Construction of granular sub-base by providing close graded Material, mixing in a mechanical mix plant at Optimum Moisture Content, carriage of mixed Material to work site, spreading in uniform layers with motor grader/ Paver on prepared surface and compacting with vibratory roller to achieve the desired density, complete as per clause 401 -- Plant Mix Method and Grading - I Material

18.06

-

2048.95

... More
Providing and laying Cast in situ/Ready Mix cement concrete in M-15 of trap/ granite/quartzite/gneiss metal for bed blocks, foundation blocks and such other items including bailing out water, Steel centering, formwork, laying/ pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etcetera complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etcetera (Wooden centering will not be allowed.), with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etcetera complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etcetera)

51.66

-

6093.3

... More
Cutting transverse contraction joints 3 to 4 mili metre wide and depth 60 mili metre .in concrete slab using concrete cutting machine with diamond studded saw within 48 hours of casting of bay / slab etcetera complete including subsequent widening of the groove 8 to 10 mili metre wide at top having depth of 15 mili metre as directed by Engineer incharge.

233.33

-

71.68

... More
VQCC Testing Charges

-

-

-

... More
Finness Modulas (Sieve Analysis), Silt Content & Clay Content

3

-

1200

... More
Water Absorption, Specific Gravity, Impact Value, Crushing Value

3

-

2300

... More
Sieve Analysis for Metal

1

-

600

... More
Compressive Strength of Cement Concrete Cube (Set of 3 Cubes)

20

-

600

... More
Royalty Charges

140.76

-

141.34

... More
6% Central Goods Services & Tax + 6% State Goods Services & Tax

968922

-

0.12

... More
13] Constg. of C.C. Road & Drain from Dhondiram Hatagale to Alikalwat, Yogeshwari Beauty Parlour to Tirumala Office, Shyam Asne to Navin Mondha Road (Hanuman Nagar), Ward No.03 @ Beed Tq. Beed

-

-

-

... More
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing to proper grade and camber, applying and brooming requisite type of screening/ binding Materials to fill up the interstices of coarse aggregate, watering and compacting with Vibratory roller. to the required density. By Mechanical Means - Grading I (Using Screening Type A (13.2) mili metre Aggregate)

117

-

2082.18

... More
Providing and laying 125 micron Low Density Polyethylene (LDPE) sheet Confirming to Indian Standard 3395 : 1997 below concrete pavement including all materials and labour complete.

1560

-

20.78

... More
Providing and laying in-situ M-30 Grade unreinforced plain cement concrete pavement over a prepared sub base with 43 grade cement, coarse and fine aggregate( natural sand/ VSI grade finely washed crushed sand) conforming to IS 383, using fine and coarse aggregates combined gradation as per Table 600-3 of MORTH Specification 2013, mixed in a batching and mixing plant/ non tilting mixer and Weigh batcher as per approved mix design, admixtures, transporting to site, spreading, laying with approved make paver, compacted and finished in a continuous operation, finishing to lines and grades as directed by Engineer-in-charge and curing by curing compound /by providing cement vata in cement Mortar 1:8 @0.6 metre X 0.6 metre centre to centre, admeasuring 80 mili metre at bottom and 40 mili metre at top with depth of 75 mili metre and maintaining the same throughout curing period by any other method approved by Engineer-in-charge.

234

-

6925.37

... More
Cutting transverse contraction joints 3 to 4 mili metre wide and depth 60 mili metre .in concrete slab using concrete cutting machine with diamond studded saw within 48 hours of casting of bay / slab etcetera complete including subsequent widening of the groove 8 to 10 mili metre wide at top having depth of 15 mili metre as directed by Engineer incharge.

1933.33

-

71.68

... More
Excavation for catch / side water gutter in all sorts of soils to the specified section including stacking the excavated stuff in a regular bund and disposing of unsuitable or excess stuff as directed all sorts of soils.

402.48

-

75.86

... More
Construction of granular sub-base by providing close graded Material, mixing in a mechanical mix plant at Optimum Moisture Content, carriage of mixed Material to work site, spreading in uniform layers with motor grader/ Paver on prepared surface and compacting with vibratory roller to achieve the desired density, complete as per clause 401 -- Plant Mix Method and Grading - I Material

67.08

-

2048.95

... More
Providing and laying Cast in situ/Ready Mix cement concrete in M-15 of trap/ granite/quartzite/gneiss metal for bed blocks, foundation blocks and such other items including bailing out water, Steel centering, formwork, laying/ pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etcetera complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etcetera (Wooden centering will not be allowed.), with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etcetera complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etcetera)

191.88

-

6093.3

... More
VQCC Testing Charges

-

-

-

... More
Finness Modulas (Sieve Analysis), Silt Content & Clay Content

3

-

1200

... More
Water Absorption, Specific Gravity, Impact Value, Crushing Value

3

-

2300

... More
Sieve Analysis for Metal

2

-

600

... More
Compressive Strength of Cement Concrete Cube (Set of 3 Cubes)

20

-

600

... More
Royalty Charges

457.15

-

141.34

... More
6% Central Goods Services & Tax + 6% State Goods Services & Tax

3372301

-

0.12

... More
14] Constg. of C.C. Road & Drain from Biyani's House to Pool, Mondha @ Beed Tq. Beed

-

-

-

... More
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing to proper grade and camber, applying and brooming requisite type of screening/ binding Materials to fill up the interstices of coarse aggregate, watering and compacting with Vibratory roller. to the required density. By Mechanical Means - Grading I (Using Screening Type A (13.2) mili metre Aggregate)

112.5

-

2082.18

... More
Providing and laying 125 micron Low Density Polyethylene (LDPE) sheet Confirming to Indian Standard 3395 : 1997 below concrete pavement including all materials and labour complete.

1500

-

20.78

... More
Providing and laying in-situ M-30 Grade unreinforced plain cement concrete pavement over a prepared sub base with 43 grade cement, coarse and fine aggregate( natural sand/ VSI grade finely washed crushed sand) conforming to IS 383, using fine and coarse aggregates combined gradation as per Table 600-3 of MORTH Specification 2013, mixed in a batching and mixing plant/ non tilting mixer and Weigh batcher as per approved mix design, admixtures, transporting to site, spreading, laying with approved make paver, compacted and finished in a continuous operation, finishing to lines and grades as directed by Engineer-in-charge and curing by curing compound /by providing cement vata in cement Mortar 1:8 @0.6 metre X 0.6 metre centre to centre, admeasuring 80 mili metre at bottom and 40 mili metre at top with depth of 75 mili metre and maintaining the same throughout curing period by any other method approved by Engineer-in-charge.

225

-

6925.37

... More
Cutting transverse contraction joints 3 to 4 mili metre wide and depth 60 mili metre .in concrete slab using concrete cutting machine with diamond studded saw within 48 hours of casting of bay / slab etcetera complete including subsequent widening of the groove 8 to 10 mili metre wide at top having depth of 15 mili metre as directed by Engineer incharge.

500

-

71.68

... More
Excavation for catch / side water gutter in all sorts of soils to the specified section including stacking the excavated stuff in a regular bund and disposing of unsuitable or excess stuff as directed all sorts of soils.

232.2

-

75.86

... More
Construction of granular sub-base by providing close graded Material, mixing in a mechanical mix plant at Optimum Moisture Content, carriage of mixed Material to work site, spreading in uniform layers with motor grader/ Paver on prepared surface and compacting with vibratory roller to achieve the desired density, complete as per clause 401 -- Plant Mix Method and Grading - I Material

38.7

-

2048.95

... More
Providing and laying Cast in situ/Ready Mix cement concrete in M-15 of trap/ granite/quartzite/gneiss metal for bed blocks, foundation blocks and such other items including bailing out water, Steel centering, formwork, laying/ pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etcetera complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etcetera (Wooden centering will not be allowed.), with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etcetera complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etcetera)

110.7

-

6093.3

... More
VQCC Testing Charges

-

-

-

... More
Finness Modulas (Sieve Analysis), Silt Content & Clay Content

3

-

1200

... More
Water Absorption, Specific Gravity, Impact Value, Crushing Value

3

-

2300

... More
Sieve Analysis for Metal

2

-

600

... More
Compressive Strength of Cement Concrete Cube (Set of 3 Cubes)

20

-

600

... More
Royalty Charges

408.25

-

141.34

... More
6% Central Goods Services & Tax + 6% State Goods Services & Tax

2630899

-

0.12

... More
15] Constg. of C.C. Road & Drain from Dinkar Dahiwal to Masjid, Ward No.04 @ Beed Tq. Beed

-

-

-

... More
Providing and laying 125 micron Low Density Polyethylene (LDPE) sheet Confirming to Indian Standard 3395 : 1997 below concrete pavement including all materials and labour complete.

147

-

20.78

... More
Providing and laying in-situ M-30 Grade unreinforced plain cement concrete pavement over a prepared sub base with 43 grade cement, coarse and fine aggregate( natural sand/ VSI grade finely washed crushed sand) conforming to IS 383, using fine and coarse aggregates combined gradation as per Table 600-3 of MORTH Specification 2013, mixed in a batching and mixing plant/ non tilting mixer and Weigh batcher as per approved mix design, admixtures, transporting to site, spreading, laying with approved make paver, compacted and finished in a continuous operation, finishing to lines and grades as directed by Engineer-in-charge and curing by curing compound /by providing cement vata in cement Mortar 1:8 @0.6 metre X 0.6 metre centre to centre, admeasuring 80 mili metre at bottom and 40 mili metre at top with depth of 75 mili metre and maintaining the same throughout curing period by any other method approved by Engineer-in-charge.

22.05

-

6925.37

... More
Cutting transverse contraction joints 3 to 4 mili metre wide and depth 60 mili metre .in concrete slab using concrete cutting machine with diamond studded saw within 48 hours of casting of bay / slab etcetera complete including subsequent widening of the groove 8 to 10 mili metre wide at top having depth of 15 mili metre as directed by Engineer incharge.

116.67

-

71.68

... More
Excavation for catch / side water gutter in all sorts of soils to the specified section including stacking the excavated stuff in a regular bund and disposing of unsuitable or excess stuff as directed all sorts of soils.

12.6

-

75.86

... More
Construction of granular sub-base by providing close graded Material, mixing in a mechanical mix plant at Optimum Moisture Content, carriage of mixed Material to work site, spreading in uniform layers with motor grader/ Paver on prepared surface and compacting with vibratory roller to achieve the desired density, complete as per clause 401 -- Plant Mix Method and Grading - I Material

3.15

-

2048.95

... More
Providing and laying Cast in situ/Ready Mix cement concrete in M-15 of trap/ granite/quartzite/gneiss metal for bed blocks, foundation blocks and such other items including bailing out water, Steel centering, formwork, laying/ pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etcetera complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etcetera (Wooden centering will not be allowed.), with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etcetera complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etcetera)

16.03

-

6093.3

... More
Providing and laying in situ / ready mix M-20 cement concrete of trap /granite /quartzite /gneiss metal for approach slab / Rigid pavement including compacting, finishing, curing etcetera complete. (excluding reinforcement) (with reversible drum type mixer/ concrete batch mix plant (pan mixer) with SCADA with fine aggregates of required specifications (Natural sand / VSI sand finely washed etcetera ), cement 6.40 bags/Cubic Metre)

1

-

2453.18

... More
Providing and fixing in position Thermo Mechanical Treated (TMT) - FE - 500 bar reinforcement of various diameters for Reinforced Cement Concrete pile caps, footings, foundations, slabs, beams columns, canopies, staIndian Road Congressase, newels, chajjas, lintels pardis, copings, fins, arches etcetera as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete.

3

-

65009.14

... More
VQCC Testing Charges

-

-

-

... More
Finness Modulas (Sieve Analysis), Silt Content & Clay Content

3

-

1200

... More
Water Absorption, Specific Gravity, Impact Value, Crushing Value

3

-

2300

... More
Compressive Strength of Cement Concrete Cube (Set of 3 Cubes)

20

-

600

... More
Royalty Charges

29.95

-

141.34

... More
6% Central Goods Services & Tax + 6% State Goods Services & Tax

466688

-

0.12

... More
16] Constg. of C.C. Road & Drain from Kale to Burande House (Dube Colony) at Ward No.04 @ Beed Tq. Beed

-

-

-

... More
Excavation for roadway in earth, soil of all sorts, sand, gravel or soft murum including dressing section to the required grade, camber and side slopes and conveying the excavated materials with all lifts upto a lead of 50 metre and spreading for embankment or stacking as directed. By Manual Means. (with prior permission of S.E.)

45

-

250.35

... More
Construction of granular sub-base by providing close graded Material, mixing in a mechanical mix plant at Optimum Moisture Content, carriage of mixed Material to work site, spreading in uniform layers with motor grader / Paver on prepared surface and compacting with vibratory roller to achieve the desired density, complete as per clause 401 -- Plant Mix Method and Grading - II Material

30

-

2254.21

... More
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing to proper grade and camber, applying and brooming requisite type of screening/ binding Materials to fill up the interstices of coarse aggregate, watering and compacting with Vibratory roller. to the required density. By Mechanical Means - Grading I (Using Screening Type A (13.2) mili metre Aggregate)

28.13

-

2081.58

... More
Providing and laying 125 micron Low Density Polyethylene (LDPE) sheet Confirming to Indian Standard 3395 : 1997 below concrete pavement including all materials and labour complete.

375

-

20.78

... More
Providing and laying in-situ M-30 Grade unreinforced plain cement concrete pavement over a prepared sub base with 43 grade cement, coarse and fine aggregate( natural sand/ VSI grade finely washed crushed sand) conforming to IS 383, using fine and coarse aggregates combined gradation as per Table 600-3 of MORTH Specification 2013, mixed in a batching and mixing plant/ non tilting mixer and Weigh batcher as per approved mix design, admixtures, transporting to site, spreading, laying with approved make paver, compacted and finished in a continuous operation, finishing to lines and grades as directed by Engineer-in-charge and curing by curing compound /by providing cement vata in cement Mortar 1:8 @0.6 metre X 0.6 metre centre to centre, admeasuring 80 mili metre at bottom and 40 mili metre at top with depth of 75 mili metre and maintaining the same throughout curing period by any other method approved by Engineer-in-charge.

56.25

-

6925.37

... More
Cutting transverse contraction joints 3 to 4 mili metre wide and depth 60 mili metre .in concrete slab using concrete cutting machine with diamond studded saw within 48 hours of casting of bay / slab etcetera complete including subsequent widening of the groove 8 to 10 mili metre wide at top having depth of 15 mili metre as directed by Engineer incharge.

125

-

71.68

... More
Excavation for catch / side water gutter in all sorts of soils to the specified section including stacking the excavated stuff in a regular bund and disposing of unsuitable or excess stuff as directed all sorts of soils.

58.05

-

75.86

... More
Construction of granular sub-base by providing close graded Material, mixing in a mechanical mix plant at Optimum Moisture Content, carriage of mixed Material to work site, spreading in uniform layers with motor grader/ Paver on prepared surface and compacting with vibratory roller to achieve the desired density, complete as per clause 401 -- Plant Mix Method and Grading - I Material

9.68

-

2048.95

... More
Providing and laying Cast in situ/Ready Mix cement concrete in M-15 of trap/ granite/quartzite/gneiss metal for bed blocks, foundation blocks and such other items including bailing out water, Steel centering, formwork, laying/ pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etcetera complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etcetera (Wooden centering will not be allowed.), with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etcetera complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etcetera)

27.68

-

6093.3

... More
VQCC Testing Charges

-

-

-

... More
Finness Modulas (Sieve Analysis), Silt Content & Clay Content

3

-

1200

... More
Water Absorption, Specific Gravity, Impact Value, Crushing Value

3

-

2300

... More
Sieve Analysis for Metal

1

-

600

... More
Compressive Strength of Cement Concrete Cube (Set of 3 Cubes)

20

-

600

... More
Royalty Charges

102.96

-

141.34

... More
6% Central Goods Services & Tax + 6% State Goods Services & Tax

736642

-

0.12

... More
17] Constg. of Gym School, Nagoba Galli at Govt. Chavadi Pr. No.4 @ Beed Tq. Beed

-

-

-

... More
Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 metre beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etcetera complete. (Lift upto 1.5 metre) By Mechanical Means

23.33

-

157

... More
Excavation for foundation in hard murum including removing the excavated material upto distance of 50 Metre beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etcetera complete. (Lift upto 1.50 metre) By Mechanical Means

23.33

-

196

... More
Providing soling using 80 mili metre size trap metal in 15 centi metre layer including filling voids with Crushed sand/grit, ramming, watering etcetera complete.

2.59

-

1633.83

... More
Providing and laying Cast in situ/Ready Mix cement concrete in M-15 of trap/ granite/quartzite/gneiss metal for bed blocks, foundation blocks and such other items including bailing out water, Steel centering, formwork, laying/ pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etcetera complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etcetera (Wooden centering will not be allowed.), with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etcetera complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etcetera)

8.08

-

6107.25

... More
Providing and laying in situ /Ready Mix cement concrete M-20 of trap / granite /quartzite/ gneiss metal for Reinforced Cement Concrete work in foundations like raft, strip foundations, grillage and footings of Reinforced Cement Concrete columns and steel stanchions etcetera including bailing out water, Steel centering formwork, laying/ pumping cover blocks, compaction and curing roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etcetera complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etcetera complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etcetera)

10.8

-

6797.18

... More
Providing and laying Cast in situ/Ready Mix cement concrete M-20 of trap / granite /quartzite/ gneiss metal for Reinforced Cement Concrete columns as per detailed designs and drawing or as directed including steel centering, formwork, cover blocks, laying/ pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etcetera complete,(Excluding reinforcement and structural steel) with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etcetera complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etcetera)

4.97

-

12603.05

... More
Providing and laying Cast in situ/Ready Mix cement concrete M-20 of trap / granite /quartzite/ gneiss metal for Reinforced Cement Concrete beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/ pumping, compactionand roughening the surface if special finish is to be provided and curing etcetera complete. (Excluding reinforcement and structural steel) with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etcetera complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etcetera)

3.46

-

11165.98

... More
Filling in plinth and floors with approved excavated material in 15 centi metre. to 20 centi metre layers including watering and compacting etcetera complete.

95.13

-

96

... More
Providing and laying Cast in situ/Ready Mix cement concrete M-20 of trap/ granite / quartzite/ gneiss metal for Reinforced Cement Concrete slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks, laying/ pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etcetera complete,(Excluding reinforcement and structural steel) with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etcetera complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etcetera)

7.24

-

13378.44

... More
Providing and laying Cast in situ/Ready Mix cement concrete in M-20 of trap / quartzite /granite /gneiss metal for Reinforced Cement Concrete Waist slab, and steps of staIndian Road Congressases as per detailed design and drawings or as directed including steel centering, formwork, steel props, laying/ pumping, compaction, finishing uneven and honeycombed surface with Cement Mortor 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing etcetera complete. (Excluding einforcement, including cover block).(Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etcetera) with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etcetera complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etcetera)

0.85

-

13150.25

... More
Providing and fixing in position Thermo Mechanical Treated (TMT) - FE - 500 bar reinforcement of various diameters for Reinforced Cement Concrete pile caps, footings, foundations, slabs, beams columns, canopies, staIndian Road Congressase, newels, chajjas, lintels pardis, copings, fins, arches etcetera as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete.

2.57

-

62581

... More
Providing second class Burnt Brick masonry with conventional/ Indian Standard type bricks in cement mortar 1:6 in foundations and plinth of inner walls/ in plinth external walls including bailing out water manually, striking joints on unexposed faces, raking out joints on exposed faces and watering etcetera Complete.

7.52

-

6421.54

... More
Providing second class Burnt Brick masonry with conventional/ Indian Standard type bricks in cement mortar 1:6 in superstructure including striking joints, raking out joints, watering and scaffolding etcetera Complete

23.99

-

6612.75

... More
Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 mili metre thick in cement mortar 1:4 using waterproofing compound at 1 Kilogram per cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 mili metre thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etcetera complete.

167.97

-

1079.01

... More
Providing internal cement plaster 20 mili metre thick in two coats in cement mortar 1:5 without neeru finish, to concrete, brick surface, in all positions including scaffolding and curing etcetera complete

93.71

-

465.39

... More
Providing internal cement plaster 12 mili metre thick in single coat in cement mortar 1:3 without neeru finish to concrete or brick surfaces, in all position including scaffolding and curing etcetera complete.

48.92

-

279.37

... More
Providing and laying vitrified matt fininsh tiles having size 590 mili metre to 605 mili metre x to 605 mili metre of 8 to 10 mili metre thickness and confirming Indian Standard 15622-2006 (Group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement morar including neat cement float, filling joints, curing and cleaning etcetera complete. a) Flooring

48.93

-

1840.74

... More
Providing and laying vitrified matt finish tiles having size 590 mili metre to 605 mili metre x to 605 mili metre of 8 to 10 mili metre thickness and confirming Indian Standard 15622-2006 (Group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and cleaning etcetera complete. b) Skirting

2.86

-

2195.11

... More
Providing and laying telephone black / Amba White / Cadburybrown / Ruby red / Ocean Brown granite stone of 18 to 20 mili metre thick for door frame/ dado/ window boxing etcetera On Cement Mortor 1:6 including filling joints with polymer base filler nosing/moulding the sharp edges wherever necessary, curing, etcetera complete.

3

-

4108.65

... More
Providing and applying two coats of exterior acraylic emulsion paint confirming to corresponding Indian Standard of approved manufacture and of approved colour to the plastered surfaces including cleaning ,preparing the plaster surface, applying primer coat ,scaffolding if necessary, and watering the surface for two days etcetera complete.

167.97

-

215

... More
Providing and applying two coats of textured synthetic paint of approved shade and quality and one coat of primer before applying textured paint including scaffolding if necessary preparing surface by thoroughly cleaning oil, grease, dirt and other materials as required, etcetera complete.

142.63

-

137

... More
Providing and laying telephone black / Amba White / Cadburybrown / Ruby red / Ocean Brown granite stone of 18 to 20 mili metre thick for door frame/ dado/ window boxing etcetera On Cement Mortor 1:6 including filling joints with polymer base filler nosing/moulding the sharp edges wherever necessary, curing, etcetera complete.

9.03

-

4110.51

... More
Providing and laying Cast in situ/Ready Mix cement concrete M-15 of trap/ granite/quartzite/gneiss metal for coping to plinth or parapet, moulded or chamfered as per drawing or as directed including steel centering, plywood/ steel formwork compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etcetera complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etcetera (Wooden centering will not be allowed.) With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etcetera)

0.84

-

6260.3

... More
Providing and fixing mild steel grill work for windows, ventilators etcetera 20 Kilogram/Square Metre as per drawing including fixtures, necessary welding and painting with one coats of anticorrosive paint and two coats of oil painting complete.

4.32

-

1528

... More
Providing and fixing in position. (as per Indian Standard 1868 / 1982) Aluminium sliding window of two tracks with rectangular pipe having overall dimension 63.50 x 38.10 x 1.02 mili metre at weight 0.547 Kilogram/Running Metre and window frame bottom track section 61.85 x 31.75 x 1.20 mili metre at weight 0.695 Kilogram/Running Metre Top and side track section 61.85 x 31.75 x 1.30 mili metre at weight 0.659 Kilogram/Running Metre The shutter should be of bearing bottom 40 x 18 x 1.25 mili metre at weight 0.417 Kilogram/Running Metre Inter locking section 40 x 18 x 1.10 mili metre at weight 0.469 Kilogram/Running Metre And handle section 40 x 18 x 1.25 mili metre at weight 0.417 Kilogram/Running Metre and top section 40 x 18 x 1.25 mili metre at weight 0.417 Kilogram/Running Metre As per detailed drawings and as directed by Engineer in charge with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 mili metre thick plain glass with all required screws and nuts etcetera complete. With powder coating with box

4.32

-

5385

... More
Providing and fixing frame with / without ventilator of size as specified with Country cut teak wood for doors and windows including chamfering, rounding, rebating, iron holdfast of size 300 mili metre x 40 mili metre x 5 mili metre with oil painting, etcetera complete

0.05

-

164576

... More
Providing and fixing Country cut teak wood double or single leaf second class fully panelled door shutter with 35 mili metre thick style and rail with 25 mili metre thick panels with openable fan light as per detailed drawings. Excluding the door frame 60 mili metre x 100 mili metre stainless steel fixtures and fastening and finishing the wood work with oil painting 3 coats. (Excluding the door frame)

4.79

-

7828

... More
VQCC Testing Charges

-

-

-

... More
Standard Consistancy Fineness, Specific Gravity, Setting Time (Initial & Final), Compressive Strength, Soundness

1

-

3300

... More
Finness Modulas (Sieve Analysis), Silt Content & Clay Content

1

-

1200

... More
Water Absorption, Specific Gravity, Impact Value, Crushing Value

1

-

2300

... More
Sieve Analysis for Metal

1

-

600

... More
Compressive Strength of Cement Concrete Cube (Set of 3 Cubes)

1

-

600

... More
Royalty Charges

67.31

-

141.34

... More
6% Central Goods Services & Tax + 6% State Goods Services & Tax

1241873

-

0.12

... More
18] Constg. of C.C. Road & Drain from Mahamune's House to Wasant Chandne, Ward No.04 @ Beed Tq. Beed

-

-

-

... More
Providing and laying 125 micron Low Density Polyethylene (LDPE) sheet Confirming to Indian Standard 3395 : 1997 below concrete pavement including all materials and labour complete.

225

-

20.78

... More
Providing and laying in-situ M-30 Grade unreinforced plain cement concrete pavement over a prepared sub base with 43 grade cement, coarse and fine aggregate( natural sand/ VSI grade finely washed crushed sand) conforming to IS 383, using fine and coarse aggregates combined gradation as per Table 600-3 of MORTH Specification 2013, mixed in a batching and mixing plant/ non tilting mixer and Weigh batcher as per approved mix design, admixtures, transporting to site, spreading, laying with approved make paver, compacted and finished in a continuous operation, finishing to lines and grades as directed by Engineer-in-charge and curing by curing compound /by providing cement vata in cement Mortar 1:8 @0.6 metre X 0.6 metre centre to centre, admeasuring 80 mili metre at bottom and 40 mili metre at top with depth of 75 mili metre and maintaining the same throughout curing period by any other method approved by Engineer-in-charge.

33.75

-

6925.37

... More
Cutting transverse contraction joints 3 to 4 mili metre wide and depth 60 mili metre .in concrete slab using concrete cutting machine with diamond studded saw within 48 hours of casting of bay / slab etcetera complete including subsequent widening of the groove 8 to 10 mili metre wide at top having depth of 15 mili metre as directed by Engineer incharge.

125

-

71.68

... More
Excavation for catch / side water gutter in all sorts of soils to the specified section including stacking the excavated stuff in a regular bund and disposing of unsuitable or excess stuff as directed all sorts of soils.

58.05

-

75.86

... More
Construction of granular sub-base by providing close graded Material, mixing in a mechanical mix plant at Optimum Moisture Content, carriage of mixed Material to work site, spreading in uniform layers with motor grader/ Paver on prepared surface and compacting with vibratory roller to achieve the desired density, complete as per clause 401 -- Plant Mix Method and Grading - I Material

9.68

-

2048.95

... More
Providing and laying Cast in situ/Ready Mix cement concrete in M-15 of trap/ granite/quartzite/gneiss metal for bed blocks, foundation blocks and such other items including bailing out water, Steel centering, formwork, laying/ pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etcetera complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etcetera (Wooden centering will not be allowed.), with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etcetera complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etcetera)

27.68

-

6093.3

... More
VQCC Testing Charges

-

-

-

... More
Finness Modulas (Sieve Analysis), Silt Content & Clay Content

3

-

1200

... More
Water Absorption, Specific Gravity, Impact Value, Crushing Value

3

-

2300

... More
Compressive Strength of Cement Concrete Cube (Set of 3 Cubes)

20

-

600

... More
Royalty Charges

46.54

-

141.34

... More
6% Central Goods Services & Tax + 6% State Goods Services & Tax

440257

-

0.12

... More
19] Constg. of C.C. Road & Drain from Nirmal House to Inkar House, Kailas Thokal to Korde House, Saudagar Jadhav to Mote House (Ekta Nagar), Ward No.04 @ Beed Tq. Beed

-

-

-

... More
Excavation for roadway in earth, soil of all sorts, sand, gravel or soft murum including dressing section to the required grade, camber and side slopes and conveying the excavated materials with all lifts upto a lead of 50 metre and spreading for embankment or stacking as directed. By Manual Means. (with prior permission of S.E.)

135

-

250.35

... More
Construction of granular sub-base by providing close graded Material, mixing in a mechanical mix plant at Optimum Moisture Content, carriage of mixed Material to work site, spreading in uniform layers with motor grader / Paver on prepared surface and compacting with vibratory roller to achieve the desired density, complete as per clause 401 -- Plant Mix Method and Grading - II Material

90

-

2254.21

... More
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing to proper grade and camber, applying and brooming requisite type of screening/ binding Materials to fill up the interstices of coarse aggregate, watering and compacting with Vibratory roller. to the required density. By Mechanical Means - Grading I (Using Screening Type A (13.2) mili metre Aggregate)

67.5

-

2081.58

... More
Providing and laying 125 micron Low Density Polyethylene (LDPE) sheet Confirming to Indian Standard 3395 : 1997 below concrete pavement including all materials and labour complete.

900

-

20.78

... More
Providing and laying in-situ M-30 Grade unreinforced plain cement concrete pavement over a prepared sub base with 43 grade cement, coarse and fine aggregate( natural sand/ VSI grade finely washed crushed sand) conforming to IS 383, using fine and coarse aggregates combined gradation as per Table 600-3 of MORTH Specification 2013, mixed in a batching and mixing plant/ non tilting mixer and Weigh batcher as per approved mix design, admixtures, transporting to site, spreading, laying with approved make paver, compacted and finished in a continuous operation, finishing to lines and grades as directed by Engineer-in-charge and curing by curing compound /by providing cement vata in cement Mortar 1:8 @0.6 metre X 0.6 metre centre to centre, admeasuring 80 mili metre at bottom and 40 mili metre at top with depth of 75 mili metre and maintaining the same throughout curing period by any other method approved by Engineer-in-charge.

135

-

6925.37

... More
Cutting transverse contraction joints 3 to 4 mili metre wide and depth 60 mili metre .in concrete slab using concrete cutting machine with diamond studded saw within 48 hours of casting of bay / slab etcetera complete including subsequent widening of the groove 8 to 10 mili metre wide at top having depth of 15 mili metre as directed by Engineer incharge.

600

-

71.68

... More
Excavation for catch / side water gutter in all sorts of soils to the specified section including stacking the excavated stuff in a regular bund and disposing of unsuitable or excess stuff as directed all sorts of soils.

139.32

-

75.86

... More
Construction of granular sub-base by providing close graded Material, mixing in a mechanical mix plant at Optimum Moisture Content, carriage of mixed Material to work site, spreading in uniform layers with motor grader/ Paver on prepared surface and compacting with vibratory roller to achieve the desired density, complete as per clause 401 -- Plant Mix Method and Grading - I Material

23.22

-

2048.95

... More
Providing and laying Cast in situ/Ready Mix cement concrete in M-15 of trap/ granite/quartzite/gneiss metal for bed blocks, foundation blocks and such other items including bailing out water, Steel centering, formwork, laying/ pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etcetera complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etcetera (Wooden centering will not be allowed.), with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etcetera complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etcetera)

66.42

-

6093.3

... More
VQCC Testing Charges

-

-

-

... More
Finness Modulas (Sieve Analysis), Silt Content & Clay Content

3

-

1200

... More
Water Absorption, Specific Gravity, Impact Value, Crushing Value

3

-

2300

... More
Sieve Analysis for Metal

1

-

600

... More
Compressive Strength of Cement Concrete Cube (Set of 3 Cubes)

10

-

600

... More
Royalty Charges

245.43

-

141.34

... More
6% Central Goods Services & Tax + 6% State Goods Services & Tax

1836679

-

0.12

... More
20] Constg. of C.C. Road & Drain from Dhomre's House to Shinde's House @ Beed Tq. Beed

-

-

-

... More
Providing and laying 125 micron Low Density Polyethylene (LDPE) sheet Confirming to Indian Standard 3395 : 1997 below concrete pavement including all materials and labour complete.

625

-

20.78

... More
Providing and laying in-situ M-30 Grade unreinforced plain cement concrete pavement over a prepared sub base with 43 grade cement, coarse and fine aggregate( natural sand/ VSI grade finely washed crushed sand) conforming to IS 383, using fine and coarse aggregates combined gradation as per Table 600-3 of MORTH Specification 2013, mixed in a batching and mixing plant/ non tilting mixer and Weigh batcher as per approved mix design, admixtures, transporting to site, spreading, laying with approved make paver, compacted and finished in a continuous operation, finishing to lines and grades as directed by Engineer-in-charge and curing by curing compound /by providing cement vata in cement Mortar 1:8 @0.6 metre X 0.6 metre centre to centre, admeasuring 80 mili metre at bottom and 40 mili metre at top with depth of 75 mili metre and maintaining the same throughout curing period by any other method approved by Engineer-in-charge.

93.75

-

6925.37

... More
Excavation for catch / side water gutter in all sorts of soils to the specified section including stacking the excavated stuff in a regular bund and disposing of unsuitable or excess stuff as directed all sorts of soils.

96.75

-

75.86

... More
Construction of granular sub-base by providing close graded Material, mixing in a mechanical mix plant at Optimum Moisture Content, carriage of mixed Material to work site, spreading in uniform layers with motor grader/ Paver on prepared surface and compacting with vibratory roller to achieve the desired density, complete as per clause 401 -- Plant Mix Method and Grading - I Material

16.13

-

2048.95

... More
Providing and laying Cast in situ/Ready Mix cement concrete in M-15 of trap/ granite/quartzite/gneiss metal for bed blocks, foundation blocks and such other items including bailing out water, Steel centering, formwork, laying/ pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etcetera complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etcetera (Wooden centering will not be allowed.), with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etcetera complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etcetera)

46.13

-

6093.3

... More
Cutting transverse contraction joints 3 to 4 mili metre wide and depth 60 mili metre .in concrete slab using concrete cutting machine with diamond studded saw within 48 hours of casting of bay / slab etcetera complete including subsequent widening of the groove 8 to 10 mili metre wide at top having depth of 15 mili metre as directed by Engineer incharge.

208.33

-

71.68

... More
VQCC Testing Charges

-

-

-

... More
Finness Modulas (Sieve Analysis), Silt Content & Clay Content

3

-

1200

... More
Water Absorption, Specific Gravity, Impact Value, Crushing Value

3

-

2300

... More
Compressive Strength of Cement Concrete Cube (Set of 3 Cubes)

20

-

600

... More
Royalty Charges

114.08

-

141.34

... More
6% Central Goods Services & Tax + 6% State Goods Services & Tax

998636

-

0.12

... More
21] Constg. of C.C. Road & Drain from Mandve to Kale's House, Upre's House to Jagdale's House, Adarsh Colony @ Beed Tq. Beed

-

-

-

... More
Excavation for roadway in earth, soil of all sorts, sand, gravel or soft murum including dressing section to the required grade, camber and side slopes and conveying the excavated materials with all lifts upto a lead of 50 metre and spreading for embankment or stacking as directed. By Manual Means. (with prior permission of S.E.)

300

-

250.35

... More
Construction of granular sub-base by providing close graded Material, mixing in a mechanical mix plant at Optimum Moisture Content, carriage of mixed Material to work site, spreading in uniform layers with motor grader / Paver on prepared surface and compacting with vibratory roller to achieve the desired density, complete as per clause 401 -- Plant Mix Method and Grading - II Material

200

-

2254.21

... More
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing to proper grade and camber, applying and brooming requisite type of screening/ binding Materials to fill up the interstices of coarse aggregate, watering and compacting with Vibratory roller. to the required density. By Mechanical Means - Grading I (Using Screening Type A (13.2) mili metre Aggregate)

150

-

2081.58

... More
Providing and laying 125 micron Low Density Polyethylene (LDPE) sheet Confirming to Indian Standard 3395 : 1997 below concrete pavement including all materials and labour complete.

2000

-

20.78

... More
Providing and laying in-situ M-30 Grade unreinforced plain cement concrete pavement over a prepared sub base with 43 grade cement, coarse and fine aggregate( natural sand/ VSI grade finely washed crushed sand) conforming to IS 383, using fine and coarse aggregates combined gradation as per Table 600-3 of MORTH Specification 2013, mixed in a batching and mixing plant/ non tilting mixer and Weigh batcher as per approved mix design, admixtures, transporting to site, spreading, laying with approved make paver, compacted and finished in a continuous operation, finishing to lines and grades as directed by Engineer-in-charge and curing by curing compound /by providing cement vata in cement Mortar 1:8 @0.6 metre X 0.6 metre centre to centre, admeasuring 80 mili metre at bottom and 40 mili metre at top with depth of 75 mili metre and maintaining the same throughout curing period by any other method approved by Engineer-in-charge.

300

-

6925.37

... More
Cutting transverse contraction joints 3 to 4 mili metre wide and depth 60 mili metre .in concrete slab using concrete cutting machine with diamond studded saw within 48 hours of casting of bay / slab etcetera complete including subsequent widening of the groove 8 to 10 mili metre wide at top having depth of 15 mili metre as directed by Engineer incharge.

666.67

-

71.68

... More
Excavation for catch / side water gutter in all sorts of soils to the specified section including stacking the excavated stuff in a regular bund and disposing of unsuitable or excess stuff as directed all sorts of soils.

309.6

-

75.86

... More
Construction of granular sub-base by providing close graded Material, mixing in a mechanical mix plant at Optimum Moisture Content, carriage of mixed Material to work site, spreading in uniform layers with motor grader/ Paver on prepared surface and compacting with vibratory roller to achieve the desired density, complete as per clause 401 -- Plant Mix Method and Grading - I Material

51.6

-

2048.95

... More
Providing and laying Cast in situ/Ready Mix cement concrete in M-15 of trap/ granite/quartzite/gneiss metal for bed blocks, foundation blocks and such other items including bailing out water, Steel centering, formwork, laying/ pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etcetera complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etcetera (Wooden centering will not be allowed.), with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etcetera complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etcetera)

147.6

-

6093.3

... More
VQCC Testing Charges

-

-

-

... More
Finness Modulas (Sieve Analysis), Silt Content & Clay Content

3

-

1200

... More
Water Absorption, Specific Gravity, Impact Value, Crushing Value

3

-

2300

... More
Sieve Analysis for Metal

2

-

600

... More
Compressive Strength of Cement Concrete Cube (Set of 3 Cubes)

20

-

600

... More
Royalty Charges

543.93

-

141.34

... More
6% Central Goods Services & Tax + 6% State Goods Services & Tax

4033723

-

0.12

... More
22] Constg. of C.C. Road & Drain from Mule's House to Tangde's House, Krushi Colony @ Beed Tq. Beed

-

-

-

... More
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing to proper grade and camber, applying and brooming requisite type of screening/ binding Materials to fill up the interstices of coarse aggregate, watering and compacting with Vibratory roller. to the required density. By Mechanical Means - Grading I (Using Screening Type A (13.2) mili metre Aggregate)

52.5

-

2082.18

... More
Providing and laying 125 micron Low Density Polyethylene (LDPE) sheet Confirming to Indian Standard 3395 : 1997 below concrete pavement including all materials and labour complete.

700

-

20.78

... More
Providing and laying in-situ M-30 Grade unreinforced plain cement concrete pavement over a prepared sub base with 43 grade cement, coarse and fine aggregate( natural sand/ VSI grade finely washed crushed sand) conforming to IS 383, using fine and coarse aggregates combined gradation as per Table 600-3 of MORTH Specification 2013, mixed in a batching and mixing plant/ non tilting mixer and Weigh batcher as per approved mix design, admixtures, transporting to site, spreading, laying with approved make paver, compacted and finished in a continuous operation, finishing to lines and grades as directed by Engineer-in-charge and curing by curing compound /by providing cement vata in cement Mortar 1:8 @0.6 metre X 0.6 metre centre to centre, admeasuring 80 mili metre at bottom and 40 mili metre at top with depth of 75 mili metre and maintaining the same throughout curing period by any other method approved by Engineer-in-charge.

105

-

6925.37

... More
Excavation for catch / side water gutter in all sorts of soils to the specified section including stacking the excavated stuff in a regular bund and disposing of unsuitable or excess stuff as directed all sorts of soils.

108.36

-

75.86

... More
Construction of granular sub-base by providing close graded Material, mixing in a mechanical mix plant at Optimum Moisture Content, carriage of mixed Material to work site, spreading in uniform layers with motor grader/ Paver on prepared surface and compacting with vibratory roller to achieve the desired density, complete as per clause 401 -- Plant Mix Method and Grading - I Material

18.06

-

2048.95

... More
Providing and laying Cast in situ/Ready Mix cement concrete in M-15 of trap/ granite/quartzite/gneiss metal for bed blocks, foundation blocks and such other items including bailing out water, Steel centering, formwork, laying/ pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etcetera complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etcetera (Wooden centering will not be allowed.), with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etcetera complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etcetera)

51.66

-

6093.3

... More
Cutting transverse contraction joints 3 to 4 mili metre wide and depth 60 mili metre .in concrete slab using concrete cutting machine with diamond studded saw within 48 hours of casting of bay / slab etcetera complete including subsequent widening of the groove 8 to 10 mili metre wide at top having depth of 15 mili metre as directed by Engineer incharge.

233.33

-

71.68

... More
VQCC Testing Charges

-

-

-

... More
Finness Modulas (Sieve Analysis), Silt Content & Clay Content

3

-

1200

... More
Water Absorption, Specific Gravity, Impact Value, Crushing Value

3

-

2300

... More
Sieve Analysis for Metal

1

-

600

... More
Compressive Strength of Cement Concrete Cube (Set of 3 Cubes)

20

-

600

... More
Royalty Charges

191.16

-

141.34

... More
6% Central Goods Services & Tax + 6% State Goods Services & Tax

1227752

-

0.12

... More
23] Constg. of C.C. Road & Drain from Pandit House to Godawari Niwas, Ganesh Seth to Tukaram Tandle, Tukaram Tandle to Gorve, Matoshri Niwas to Murkute House, Savata Nagar Purv @ Beed Tq. Beed

-

-

-

... More
Excavation for roadway in earth, soil of all sorts, sand, gravel or soft murum including dressing section to the required grade, camber and side slopes and conveying the excavated materials with all lifts upto a lead of 50 metre and spreading for embankment or stacking as directed. By Manual Means. (with prior permission of S.E.)

322.5

-

250.35

... More
Construction of granular sub-base by providing close graded Material, mixing in a mechanical mix plant at Optimum Moisture Content, carriage of mixed Material to work site, spreading in uniform layers with motor grader / Paver on prepared surface and compacting with vibratory roller to achieve the desired density, complete as per clause 401 -- Plant Mix Method and Grading - II Material

215

-

2254.21

... More
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing to proper grade and camber, applying and brooming requisite type of screening/ binding Materials to fill up the interstices of coarse aggregate, watering and compacting with Vibratory roller. to the required density. By Mechanical Means - Grading I (Using Screening Type A (13.2) mili metre Aggregate)

161.25

-

2081.58

... More
Providing and laying 125 micron Low Density Polyethylene (LDPE) sheet Confirming to Indian Standard 3395 : 1997 below concrete pavement including all materials and labour complete.

2150

-

20.78

... More
Providing and laying in-situ M-30 Grade unreinforced plain cement concrete pavement over a prepared sub base with 43 grade cement, coarse and fine aggregate( natural sand/ VSI grade finely washed crushed sand) conforming to IS 383, using fine and coarse aggregates combined gradation as per Table 600-3 of MORTH Specification 2013, mixed in a batching and mixing plant/ non tilting mixer and Weigh batcher as per approved mix design, admixtures, transporting to site, spreading, laying with approved make paver, compacted and finished in a continuous operation, finishing to lines and grades as directed by Engineer-in-charge and curing by curing compound /by providing cement vata in cement Mortar 1:8 @0.6 metre X 0.6 metre centre to centre, admeasuring 80 mili metre at bottom and 40 mili metre at top with depth of 75 mili metre and maintaining the same throughout curing period by any other method approved by Engineer-in-charge.

322.5

-

6925.37

... More
Cutting transverse contraction joints 3 to 4 mili metre wide and depth 60 mili metre .in concrete slab using concrete cutting machine with diamond studded saw within 48 hours of casting of bay / slab etcetera complete including subsequent widening of the groove 8 to 10 mili metre wide at top having depth of 15 mili metre as directed by Engineer incharge.

716.67

-

71.68

... More
Excavation for catch / side water gutter in all sorts of soils to the specified section including stacking the excavated stuff in a regular bund and disposing of unsuitable or excess stuff as directed all sorts of soils.

332.82

-

75.86

... More
Construction of granular sub-base by providing close graded Material, mixing in a mechanical mix plant at Optimum Moisture Content, carriage of mixed Material to work site, spreading in uniform layers with motor grader/ Paver on prepared surface and compacting with vibratory roller to achieve the desired density, complete as per clause 401 -- Plant Mix Method and Grading - I Material

55.47

-

2048.95

... More
Providing and laying Cast in situ/Ready Mix cement concrete in M-15 of trap/ granite/quartzite/gneiss metal for bed blocks, foundation blocks and such other items including bailing out water, Steel centering, formwork, laying/ pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etcetera complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etcetera (Wooden centering will not be allowed.), with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etcetera complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etcetera)

158.67

-

6093.3

... More
VQCC Testing Charges

-

-

-

... More
Finness Modulas (Sieve Analysis), Silt Content & Clay Content

3

-

1200

... More
Water Absorption, Specific Gravity, Impact Value, Crushing Value

3

-

2300

... More
Sieve Analysis for Metal

2

-

600

... More
Compressive Strength of Cement Concrete Cube (Set of 3 Cubes)

20

-

600

... More
Royalty Charges

584.63

-

141.34

... More
6% Central Goods Services & Tax + 6% State Goods Services & Tax

4336252

-

0.12

... More
24] Constg. of C.C. Road & Drain from Shinde's House to Shivgare's House, Panchshil Nagar @ Beed Tq. Beed

-

-

-

... More
Providing and laying 125 micron Low Density Polyethylene (LDPE) sheet Confirming to Indian Standard 3395 : 1997 below concrete pavement including all materials and labour complete.

625

-

20.78

... More
Providing and laying in-situ M-30 Grade unreinforced plain cement concrete pavement over a prepared sub base with 43 grade cement, coarse and fine aggregate( natural sand/ VSI grade finely washed crushed sand) conforming to IS 383, using fine and coarse aggregates combined gradation as per Table 600-3 of MORTH Specification 2013, mixed in a batching and mixing plant/ non tilting mixer and Weigh batcher as per approved mix design, admixtures, transporting to site, spreading, laying with approved make paver, compacted and finished in a continuous operation, finishing to lines and grades as directed by Engineer-in-charge and curing by curing compound /by providing cement vata in cement Mortar 1:8 @0.6 metre X 0.6 metre centre to centre, admeasuring 80 mili metre at bottom and 40 mili metre at top with depth of 75 mili metre and maintaining the same throughout curing period by any other method approved by Engineer-in-charge.

93.75

-

6925.37

... More
Excavation for catch / side water gutter in all sorts of soils to the specified section including stacking the excavated stuff in a regular bund and disposing of unsuitable or excess stuff as directed all sorts of soils.

96.75

-

75.86

... More
Construction of granular sub-base by providing close graded Material, mixing in a mechanical mix plant at Optimum Moisture Content, carriage of mixed Material to work site, spreading in uniform layers with motor grader/ Paver on prepared surface and compacting with vibratory roller to achieve the desired density, complete as per clause 401 -- Plant Mix Method and Grading - I Material

16.13

-

2048.95

... More
Providing and laying Cast in situ/Ready Mix cement concrete in M-15 of trap/ granite/quartzite/gneiss metal for bed blocks, foundation blocks and such other items including bailing out water, Steel centering, formwork, laying/ pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etcetera complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etcetera (Wooden centering will not be allowed.), with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etcetera complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etcetera)

46.13

-

6093.3

... More
Cutting transverse contraction joints 3 to 4 mili metre wide and depth 60 mili metre .in concrete slab using concrete cutting machine with diamond studded saw within 48 hours of casting of bay / slab etcetera complete including subsequent widening of the groove 8 to 10 mili metre wide at top having depth of 15 mili metre as directed by Engineer incharge.

208.33

-

71.68

... More
VQCC Testing Charges

-

-

-

... More
Finness Modulas (Sieve Analysis), Silt Content & Clay Content

3

-

1200

... More
Water Absorption, Specific Gravity, Impact Value, Crushing Value

3

-

2300

... More
Compressive Strength of Cement Concrete Cube (Set of 3 Cubes)

20

-

600

... More
Royalty Charges

114.08

-

141.34

... More
6% Central Goods Services & Tax + 6% State Goods Services & Tax

998636

-

0.12

... More
25] Constg. of C.C. Road & Drain from Tuljai Niwas to Gawde Niwas, Krushi Colony Main Road @ Beed Tq. Beed

-

-

-

... More
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing to proper grade and camber, applying and brooming requisite type of screening/ binding Materials to fill up the interstices of coarse aggregate, watering and compacting with Vibratory roller. to the required density. By Mechanical Means - Grading I (Using Screening Type A (13.2) mili metre Aggregate)

52.5

-

2082.18

... More
Providing and laying 125 micron Low Density Polyethylene (LDPE) sheet Confirming to Indian Standard 3395 : 1997 below concrete pavement including all materials and labour complete.

700

-

20.78

... More
Providing and laying in-situ M-30 Grade unreinforced plain cement concrete pavement over a prepared sub base with 43 grade cement, coarse and fine aggregate( natural sand/ VSI grade finely washed crushed sand) conforming to IS 383, using fine and coarse aggregates combined gradation as per Table 600-3 of MORTH Specification 2013, mixed in a batching and mixing plant/ non tilting mixer and Weigh batcher as per approved mix design, admixtures, transporting to site, spreading, laying with approved make paver, compacted and finished in a continuous operation, finishing to lines and grades as directed by Engineer-in-charge and curing by curing compound /by providing cement vata in cement Mortar 1:8 @0.6 metre X 0.6 metre centre to centre, admeasuring 80 mili metre at bottom and 40 mili metre at top with depth of 75 mili metre and maintaining the same throughout curing period by any other method approved by Engineer-in-charge.

105

-

6925.37

... More
Excavation for catch / side water gutter in all sorts of soils to the specified section including stacking the excavated stuff in a regular bund and disposing of unsuitable or excess stuff as directed all sorts of soils.

108.36

-

75.86

... More
Construction of granular sub-base by providing close graded Material, mixing in a mechanical mix plant at Optimum Moisture Content, carriage of mixed Material to work site, spreading in uniform layers with motor grader/ Paver on prepared surface and compacting with vibratory roller to achieve the desired density, complete as per clause 401 -- Plant Mix Method and Grading - I Material

18.06

-

2048.95

... More
Providing and laying Cast in situ/Ready Mix cement concrete in M-15 of trap/ granite/quartzite/gneiss metal for bed blocks, foundation blocks and such other items including bailing out water, Steel centering, formwork, laying/ pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etcetera complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etcetera (Wooden centering will not be allowed.), with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etcetera complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etcetera)

51.66

-

6093.3

... More
Cutting transverse contraction joints 3 to 4 mili metre wide and depth 60 mili metre .in concrete slab using concrete cutting machine with diamond studded saw within 48 hours of casting of bay / slab etcetera complete including subsequent widening of the groove 8 to 10 mili metre wide at top having depth of 15 mili metre as directed by Engineer incharge.

233.33

-

71.68

... More
VQCC Testing Charges

-

-

-

... More
Finness Modulas (Sieve Analysis), Silt Content & Clay Content

3

-

1200

... More
Water Absorption, Specific Gravity, Impact Value, Crushing Value

3

-

2300

... More
Sieve Analysis for Metal

1

-

600

... More
Compressive Strength of Cement Concrete Cube (Set of 3 Cubes)

20

-

600

... More
Royalty Charges

191.16

-

141.34

... More
6% Central Goods Services & Tax + 6% State Goods Services & Tax

1227752

-

0.12

... More
26] Constg. of C.C. Road & Drain from Barshi Road to Court Judge Rest House to Divya Garden @ Beed Tq. Beed

-

-

-

... More
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing to proper grade and camber, applying and brooming requisite type of screening/ binding Materials to fill up the interstices of coarse aggregate, watering and compacting with Vibratory roller. to the required density. By Mechanical Means - Grading I (Using Screening Type A (13.2) mili metre Aggregate)

168.75

-

2065.62

... More
Providing and laying 125 micron Low Density Polyethylene (LDPE) sheet Confirming to Indian Standard 3395 : 1997 below concrete pavement including all materials and labour complete.

1125

-

20.8

... More
Providing and laying in-situ M-30 Grade unreinforced plain cement concrete pavement over a prepared sub base with 43 grade cement, coarse and fine aggregate( natural sand/ VSI grade finely washed crushed sand) conforming to IS 383, using fine and coarse aggregates combined gradation as per Table 600-3 of MORTH Specification 2013, mixed in a batching and mixing plant/ non tilting mixer and Weigh batcher as per approved mix design, admixtures, transporting to site, spreading, laying with approved make paver, compacted and finished in a continuous operation, finishing to lines and grades as directed by Engineer-in-charge and curing by curing compound /by providing cement vata in cement Mortar 1:8 @0.6 metre X 0.6 metre centre to centre, admeasuring 80 mili metre at bottom and 40 mili metre at top with depth of 75 mili metre and maintaining the same throughout curing period by any other method approved by Engineer-in-charge.

168.75

-

6925.37

... More
Cutting transverse contraction joints 3 to 4 mili metre wide and depth 60 mili metre .in concrete slab using concrete cutting machine with diamond studded saw within 48 hours of casting of bay / slab etcetera complete including subsequent widening of the groove 8 to 10 mili metre wide at top having depth of 15 mili metre as directed by Engineer incharge.

375

-

71.76

... More
Excavation for catch / side water gutter in all sorts of soils to the specified section including stacking the excavated stuff in a regular bund and disposing of unsuitable or excess stuff as directed all sorts of soils.

116.1

-

75.86

... More
Construction of granular sub-base by providing close graded Material, mixing in a mechanical mix plant at Optimum Moisture Content, carriage of mixed Material to work site, spreading in uniform layers with motor grader/ Paver on prepared surface and compacting with vibratory roller to achieve the desired density, complete as per clause 401 -- Plant Mix Method and Grading - I Material

19.35

-

2048.95

... More
Providing and laying Cast in situ/Ready Mix cement concrete in M-15 of trap/ granite/quartzite/gneiss metal for bed blocks, foundation blocks and such other items including bailing out water, Steel centering, formwork, laying/ pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etcetera complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etcetera (Wooden centering will not be allowed.), with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etcetera complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etcetera)

55.35

-

6170.02

... More
VQCC Testing Charges

-

-

-

... More
Finness Modulas (Sieve Analysis), Silt Content & Clay Content

1

-

1200

... More
Water Absorption, Specific Gravity, Impact Value, Crushing Value

1

-

2300

... More
Sieve Analysis for Metal

2

-

600

... More
Compressive Strength of Cement Concrete Cube (Set of 3 Cubes)

17

-

600

... More
Royalty Charges

396.82

-

141.34

... More
6% Central Goods Services & Tax + 6% State Goods Services & Tax

1957504

-

0.12

... More
27] Constg. of C.C. Road from Jyanta Rakh to Natyagrah @ Beed Tq. Beed

-

-

-

... More
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing to proper grade and camber, applying and brooming requisite type of screening/ binding Materials to fill up the interstices of coarse aggregate, watering and compacting with Vibratory roller. to the required density. By Mechanical Means - Grading I (Using Screening Type A (13.2) mili metre Aggregate)

45

-

2065.62

... More
Providing and laying 125 micron Low Density Polyethylene (LDPE) sheet Confirming to Indian Standard 3395 : 1997 below concrete pavement including all materials and labour complete.

300

-

20.8

... More
Providing and laying in-situ M-30 Grade unreinforced plain cement concrete pavement over a prepared sub base with 43 grade cement, coarse and fine aggregate( natural sand/ VSI grade finely washed crushed sand) conforming to IS 383, using fine and coarse aggregates combined gradation as per Table 600-3 of MORTH Specification 2013, mixed in a batching and mixing plant/ non tilting mixer and Weigh batcher as per approved mix design, admixtures, transporting to site, spreading, laying with approved make paver, compacted and finished in a continuous operation, finishing to lines and grades as directed by Engineer-in-charge and curing by curing compound /by providing cement vata in cement Mortar 1:8 @0.6 metre X 0.6 metre centre to centre, admeasuring 80 mili metre at bottom and 40 mili metre at top with depth of 75 mili metre and maintaining the same throughout curing period by any other method approved by Engineer-in-charge.

45

-

6925.37

... More
Cutting transverse contraction joints 3 to 4 mili metre wide and depth 60 mili metre .in concrete slab using concrete cutting machine with diamond studded saw within 48 hours of casting of bay / slab etcetera complete including subsequent widening of the groove 8 to 10 mili metre wide at top having depth of 15 mili metre as directed by Engineer incharge.

100

-

71.76

... More
VQCC Testing Charges

-

-

-

... More
Finness Modulas (Sieve Analysis), Silt Content & Clay Content

1

-

1200

... More
Water Absorption, Specific Gravity, Impact Value, Crushing Value

1

-

2300

... More
Sieve Analysis for Metal

1

-

600

... More
Compressive Strength of Cement Concrete Cube (Set of 3 Cubes)

5

-

600

... More
Royalty Charges

99.23

-

141.34

... More
6% Central Goods Services & Tax + 6% State Goods Services & Tax

418010

-

0.12

... More
28] Constg. of C.C. Road from Wanve House to Natyagrah Road (Jayant Rakh Back Side to Natyagrah) @ Beed Tq. Beed

-

-

-

... More
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing to proper grade and camber, applying and brooming requisite type of screening/ binding Materials to fill up the interstices of coarse aggregate, watering and compacting with Vibratory roller. to the required density. By Mechanical Means - Grading I (Using Screening Type A (13.2) mili metre Aggregate)

45

-

2065.62

... More
Providing and laying 125 micron Low Density Polyethylene (LDPE) sheet Confirming to Indian Standard 3395 : 1997 below concrete pavement including all materials and labour complete.

300

-

20.8

... More
Providing and laying in-situ M-30 Grade unreinforced plain cement concrete pavement over a prepared sub base with 43 grade cement, coarse and fine aggregate( natural sand/ VSI grade finely washed crushed sand) conforming to IS 383, using fine and coarse aggregates combined gradation as per Table 600-3 of MORTH Specification 2013, mixed in a batching and mixing plant/ non tilting mixer and Weigh batcher as per approved mix design, admixtures, transporting to site, spreading, laying with approved make paver, compacted and finished in a continuous operation, finishing to lines and grades as directed by Engineer-in-charge and curing by curing compound /by providing cement vata in cement Mortar 1:8 @0.6 metre X 0.6 metre centre to centre, admeasuring 80 mili metre at bottom and 40 mili metre at top with depth of 75 mili metre and maintaining the same throughout curing period by any other method approved by Engineer-in-charge.

45

-

6925.37

... More
Cutting transverse contraction joints 3 to 4 mili metre wide and depth 60 mili metre .in concrete slab using concrete cutting machine with diamond studded saw within 48 hours of casting of bay / slab etcetera complete including subsequent widening of the groove 8 to 10 mili metre wide at top having depth of 15 mili metre as directed by Engineer incharge.

100

-

71.76

... More
VQCC Testing Charges

-

-

-

... More
Finness Modulas (Sieve Analysis), Silt Content & Clay Content

1

-

1200

... More
Water Absorption, Specific Gravity, Impact Value, Crushing Value

1

-

2300

... More
Sieve Analysis for Metal

1

-

600

... More
Compressive Strength of Cement Concrete Cube (Set of 3 Cubes)

5

-

600

... More
Royalty Charges

99.23

-

141.34

... More
6% Central Goods Services & Tax + 6% State Goods Services & Tax

418010

-

0.12

... More
29] Constg. of C.C. Road & Drain from Bahir's House to Bidwe House, Ward No.13 @ Beed Tq. Beed

-

-

-

... More
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing to proper grade and camber, applying and brooming requisite type of screening/ binding Materials to fill up the interstices of coarse aggregate, watering and compacting with Vibratory roller. to the required density. By Mechanical Means - Grading I (Using Screening Type A (13.2) mili metre Aggregate)

37.5

-

2082.18

... More
Providing and laying 125 micron Low Density Polyethylene (LDPE) sheet Confirming to Indian Standard 3395 : 1997 below concrete pavement including all materials and labour complete.

500

-

20.78

... More
Providing and laying in-situ M-30 Grade unreinforced plain cement concrete pavement over a prepared sub base with 43 grade cement, coarse and fine aggregate( natural sand/ VSI grade finely washed crushed sand) conforming to IS 383, using fine and coarse aggregates combined gradation as per Table 600-3 of MORTH Specification 2013, mixed in a batching and mixing plant/ non tilting mixer and Weigh batcher as per approved mix design, admixtures, transporting to site, spreading, laying with approved make paver, compacted and finished in a continuous operation, finishing to lines and grades as directed by Engineer-in-charge and curing by curing compound /by providing cement vata in cement Mortar 1:8 @0.6 metre X 0.6 metre centre to centre, admeasuring 80 mili metre at bottom and 40 mili metre at top with depth of 75 mili metre and maintaining the same throughout curing period by any other method approved by Engineer-in-charge.

75

-

6925.37

... More
Cutting transverse contraction joints 3 to 4 mili metre wide and depth 60 mili metre .in concrete slab using concrete cutting machine with diamond studded saw within 48 hours of casting of bay / slab etcetera complete including subsequent widening of the groove 8 to 10 mili metre wide at top having depth of 15 mili metre as directed by Engineer incharge.

166.67

-

71.68

... More
Excavation for catch / side water gutter in all sorts of soils to the specified section including stacking the excavated stuff in a regular bund and disposing of unsuitable or excess stuff as directed all sorts of soils.

77.4

-

75.86

... More
Construction of granular sub-base by providing close graded Material, mixing in a mechanical mix plant at Optimum Moisture Content, carriage of mixed Material to work site, spreading in uniform layers with motor grader/ Paver on prepared surface and compacting with vibratory roller to achieve the desired density, complete as per clause 401 -- Plant Mix Method and Grading - I Material

12.9

-

2048.95

... More
Providing and laying Cast in situ/Ready Mix cement concrete in M-15 of trap/ granite/quartzite/gneiss metal for bed blocks, foundation blocks and such other items including bailing out water, Steel centering, formwork, laying/ pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etcetera complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etcetera (Wooden centering will not be allowed.), with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etcetera complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etcetera)

36.9

-

6093.3

... More
VQCC Testing Charges

-

-

-

... More
Finness Modulas (Sieve Analysis), Silt Content & Clay Content

3

-

1200

... More
Water Absorption, Specific Gravity, Impact Value, Crushing Value

3

-

2300

... More
Sieve Analysis for Metal

1

-

600

... More
Compressive Strength of Cement Concrete Cube (Set of 3 Cubes)

20

-

600

... More
Royalty Charges

136.88

-

141.34

... More
6% Central Goods Services & Tax + 6% State Goods Services & Tax

876967

-

0.12

... More
30] Constg. of C.C. Road from Sneha Nagar to Bahir Bapu @ Beed Tq. Beed

-

-

-

... More
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing to proper grade and camber, applying and brooming requisite type of screening/ binding Materials to fill up the interstices of coarse aggregate, watering and compacting with Vibratory roller. to the required density. By Mechanical Means - Grading I (Using Screening Type A (13.2) mili metre Aggregate)

27

-

2065.62

... More
Providing and laying 125 micron Low Density Polyethylene (LDPE) sheet Confirming to Indian Standard 3395 : 1997 below concrete pavement including all materials and labour complete.

180

-

20.8

... More
Providing and laying in-situ M-30 Grade unreinforced plain cement concrete pavement over a prepared sub base with 43 grade cement, coarse and fine aggregate( natural sand/ VSI grade finely washed crushed sand) conforming to IS 383, using fine and coarse aggregates combined gradation as per Table 600-3 of MORTH Specification 2013, mixed in a batching and mixing plant/ non tilting mixer and Weigh batcher as per approved mix design, admixtures, transporting to site, spreading, laying with approved make paver, compacted and finished in a continuous operation, finishing to lines and grades as directed by Engineer-in-charge and curing by curing compound /by providing cement vata in cement Mortar 1:8 @0.6 metre X 0.6 metre centre to centre, admeasuring 80 mili metre at bottom and 40 mili metre at top with depth of 75 mili metre and maintaining the same throughout curing period by any other method approved by Engineer-in-charge.

27

-

6925.37

... More
Cutting transverse contraction joints 3 to 4 mili metre wide and depth 60 mili metre .in concrete slab using concrete cutting machine with diamond studded saw within 48 hours of casting of bay / slab etcetera complete including subsequent widening of the groove 8 to 10 mili metre wide at top having depth of 15 mili metre as directed by Engineer incharge.

60

-

71.76

... More
VQCC Testing Charges

-

-

-

... More
Finness Modulas (Sieve Analysis), Silt Content & Clay Content

1

-

1200

... More
Water Absorption, Specific Gravity, Impact Value, Crushing Value

1

-

2300

... More
Sieve Analysis for Metal

1

-

600

... More
Compressive Strength of Cement Concrete Cube (Set of 3 Cubes)

3

-

600

... More
Royalty Charges

59.54

-

141.34

... More
6% Central Goods Services & Tax + 6% State Goods Services & Tax

250807

-

0.12

... More
31] Constg. of C.C. Road & Drain from Akhade to Ghadge @ Beed Tq. Beed

-

-

-

... More
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing to proper grade and camber, applying and brooming requisite type of screening/ binding Materials to fill up the interstices of coarse aggregate, watering and compacting with Vibratory roller. to the required density. By Mechanical Means - Grading I (Using Screening Type A (13.2) mili metre Aggregate)

30

-

2065.62

... More
Providing and laying 125 micron Low Density Polyethylene (LDPE) sheet Confirming to Indian Standard 3395 : 1997 below concrete pavement including all materials and labour complete.

200

-

20.8

... More
Providing and laying in-situ M-30 Grade unreinforced plain cement concrete pavement over a prepared sub base with 43 grade cement, coarse and fine aggregate( natural sand/ VSI grade finely washed crushed sand) conforming to IS 383, using fine and coarse aggregates combined gradation as per Table 600-3 of MORTH Specification 2013, mixed in a batching and mixing plant/ non tilting mixer and Weigh batcher as per approved mix design, admixtures, transporting to site, spreading, laying with approved make paver, compacted and finished in a continuous operation, finishing to lines and grades as directed by Engineer-in-charge and curing by curing compound /by providing cement vata in cement Mortar 1:8 @0.6 metre X 0.6 metre centre to centre, admeasuring 80 mili metre at bottom and 40 mili metre at top with depth of 75 mili metre and maintaining the same throughout curing period by any other method approved by Engineer-in-charge.

30

-

6925.37

... More
Cutting transverse contraction joints 3 to 4 mili metre wide and depth 60 mili metre .in concrete slab using concrete cutting machine with diamond studded saw within 48 hours of casting of bay / slab etcetera complete including subsequent widening of the groove 8 to 10 mili metre wide at top having depth of 15 mili metre as directed by Engineer incharge.

66.67

-

71.76

... More
Excavation for catch / side water gutter in all sorts of soils to the specified section including stacking the excavated stuff in a regular bund and disposing of unsuitable or excess stuff as directed all sorts of soils.

77.4

-

75.86

... More
Construction of granular sub-base by providing close graded Material, mixing in a mechanical mix plant at Optimum Moisture Content, carriage of mixed Material to work site, spreading in uniform layers with motor grader/ Paver on prepared surface and compacting with vibratory roller to achieve the desired density, complete as per clause 401 -- Plant Mix Method and Grading - I Material

12.9

-

2048.95

... More
Providing and laying Cast in situ/Ready Mix cement concrete in M-15 of trap/ granite/quartzite/gneiss metal for bed blocks, foundation blocks and such other items including bailing out water, Steel centering, formwork, laying/ pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etcetera complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etcetera (Wooden centering will not be allowed.), with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etcetera complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etcetera)

36.9

-

6170.02

... More
VQCC Testing Charges

-

-

-

... More
Finness Modulas (Sieve Analysis), Silt Content & Clay Content

1

-

1200

... More
Water Absorption, Specific Gravity, Impact Value, Crushing Value

1

-

2300

... More
Sieve Analysis for Metal

1

-

600

... More
Compressive Strength of Cement Concrete Cube (Set of 3 Cubes)

3

-

600

... More
Royalty Charges

83.03

-

141.34

... More
6% Central Goods Services & Tax + 6% State Goods Services & Tax

538650

-

0.12

... More
32] Constg. of C.C. Road & Drain from Wanve to Shinde @ Beed Tq. Beed

-

-

-

... More
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing to proper grade and camber, applying and brooming requisite type of screening/ binding Materials to fill up the interstices of coarse aggregate, watering and compacting with Vibratory roller. to the required density. By Mechanical Means - Grading I (Using Screening Type A (13.2) mili metre Aggregate)

30

-

2065.62

... More
Providing and laying 125 micron Low Density Polyethylene (LDPE) sheet Confirming to Indian Standard 3395 : 1997 below concrete pavement including all materials and labour complete.

200

-

20.8

... More
Providing and laying in-situ M-30 Grade unreinforced plain cement concrete pavement over a prepared sub base with 43 grade cement, coarse and fine aggregate( natural sand/ VSI grade finely washed crushed sand) conforming to IS 383, using fine and coarse aggregates combined gradation as per Table 600-3 of MORTH Specification 2013, mixed in a batching and mixing plant/ non tilting mixer and Weigh batcher as per approved mix design, admixtures, transporting to site, spreading, laying with approved make paver, compacted and finished in a continuous operation, finishing to lines and grades as directed by Engineer-in-charge and curing by curing compound /by providing cement vata in cement Mortar 1:8 @0.6 metre X 0.6 metre centre to centre, admeasuring 80 mili metre at bottom and 40 mili metre at top with depth of 75 mili metre and maintaining the same throughout curing period by any other method approved by Engineer-in-charge.

30

-

6925.37

... More
Cutting transverse contraction joints 3 to 4 mili metre wide and depth 60 mili metre .in concrete slab using concrete cutting machine with diamond studded saw within 48 hours of casting of bay / slab etcetera complete including subsequent widening of the groove 8 to 10 mili metre wide at top having depth of 15 mili metre as directed by Engineer incharge.

66.67

-

71.76

... More
Excavation for catch / side water gutter in all sorts of soils to the specified section including stacking the excavated stuff in a regular bund and disposing of unsuitable or excess stuff as directed all sorts of soils.

77.4

-

75.86

... More
Construction of granular sub-base by providing close graded Material, mixing in a mechanical mix plant at Optimum Moisture Content, carriage of mixed Material to work site, spreading in uniform layers with motor grader/ Paver on prepared surface and compacting with vibratory roller to achieve the desired density, complete as per clause 401 -- Plant Mix Method and Grading - I Material

12.9

-

2048.95

... More
Providing and laying Cast in situ/Ready Mix cement concrete in M-15 of trap/ granite/quartzite/gneiss metal for bed blocks, foundation blocks and such other items including bailing out water, Steel centering, formwork, laying/ pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etcetera complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etcetera (Wooden centering will not be allowed.), with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etcetera complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etcetera)

36.9

-

6170.02

... More
VQCC Testing Charges

-

-

-

... More
Finness Modulas (Sieve Analysis), Silt Content & Clay Content

1

-

1200

... More
Water Absorption, Specific Gravity, Impact Value, Crushing Value

1

-

2300

... More
Sieve Analysis for Metal

1

-

600

... More
Compressive Strength of Cement Concrete Cube (Set of 3 Cubes)

3

-

600

... More
Royalty Charges

83.03

-

141.34

... More
6% Central Goods Services & Tax + 6% State Goods Services & Tax

538650

-

0.12

... More
33] Constg. of C.C. Road & Drain from Kulkarni to Kshirsagar @ Beed Tq. Beed

-

-

-

... More
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing to proper grade and camber, applying and brooming requisite type of screening/ binding Materials to fill up the interstices of coarse aggregate, watering and compacting with Vibratory roller. to the required density. By Mechanical Means - Grading I (Using Screening Type A (13.2) mili metre Aggregate)

30

-

2065.62

... More
Providing and laying 125 micron Low Density Polyethylene (LDPE) sheet Confirming to Indian Standard 3395 : 1997 below concrete pavement including all materials and labour complete.

200

-

20.8

... More
Providing and laying in-situ M-30 Grade unreinforced plain cement concrete pavement over a prepared sub base with 43 grade cement, coarse and fine aggregate( natural sand/ VSI grade finely washed crushed sand) conforming to IS 383, using fine and coarse aggregates combined gradation as per Table 600-3 of MORTH Specification 2013, mixed in a batching and mixing plant/ non tilting mixer and Weigh batcher as per approved mix design, admixtures, transporting to site, spreading, laying with approved make paver, compacted and finished in a continuous operation, finishing to lines and grades as directed by Engineer-in-charge and curing by curing compound /by providing cement vata in cement Mortar 1:8 @0.6 metre X 0.6 metre centre to centre, admeasuring 80 mili metre at bottom and 40 mili metre at top with depth of 75 mili metre and maintaining the same throughout curing period by any other method approved by Engineer-in-charge.

30

-

6925.37

... More
Cutting transverse contraction joints 3 to 4 mili metre wide and depth 60 mili metre .in concrete slab using concrete cutting machine with diamond studded saw within 48 hours of casting of bay / slab etcetera complete including subsequent widening of the groove 8 to 10 mili metre wide at top having depth of 15 mili metre as directed by Engineer incharge.

66.67

-

71.76

... More
Excavation for catch / side water gutter in all sorts of soils to the specified section including stacking the excavated stuff in a regular bund and disposing of unsuitable or excess stuff as directed all sorts of soils.

77.4

-

75.86

... More
Construction of granular sub-base by providing close graded Material, mixing in a mechanical mix plant at Optimum Moisture Content, carriage of mixed Material to work site, spreading in uniform layers with motor grader/ Paver on prepared surface and compacting with vibratory roller to achieve the desired density, complete as per clause 401 -- Plant Mix Method and Grading - I Material

12.9

-

2048.95

... More
Providing and laying Cast in situ/Ready Mix cement concrete in M-15 of trap/ granite/quartzite/gneiss metal for bed blocks, foundation blocks and such other items including bailing out water, Steel centering, formwork, laying/ pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etcetera complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etcetera (Wooden centering will not be allowed.), with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etcetera complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etcetera)

36.9

-

6170.02

... More
VQCC Testing Charges

-

-

-

... More
Finness Modulas (Sieve Analysis), Silt Content & Clay Content

1

-

1200

... More
Water Absorption, Specific Gravity, Impact Value, Crushing Value

1

-

2300

... More
Sieve Analysis for Metal

1

-

600

... More
Compressive Strength of Cement Concrete Cube (Set of 3 Cubes)

3

-

600

... More
Royalty Charges

83.03

-

141.34

... More
6% Central Goods Services & Tax + 6% State Goods Services & Tax

538650

-

0.12

... More
34] Constg. of C.C. Road from Ghadge to Shinde @ Beed Tq. Beed

-

-

-

... More
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing to proper grade and camber, applying and brooming requisite type of screening/ binding Materials to fill up the interstices of coarse aggregate, watering and compacting with Vibratory roller. to the required density. By Mechanical Means - Grading I (Using Screening Type A (13.2) mili metre Aggregate)

45

-

2065.62

... More
Providing and laying 125 micron Low Density Polyethylene (LDPE) sheet Confirming to Indian Standard 3395 : 1997 below concrete pavement including all materials and labour complete.

300

-

20.8

... More
Providing and laying in-situ M-30 Grade unreinforced plain cement concrete pavement over a prepared sub base with 43 grade cement, coarse and fine aggregate( natural sand/ VSI grade finely washed crushed sand) conforming to IS 383, using fine and coarse aggregates combined gradation as per Table 600-3 of MORTH Specification 2013, mixed in a batching and mixing plant/ non tilting mixer and Weigh batcher as per approved mix design, admixtures, transporting to site, spreading, laying with approved make paver, compacted and finished in a continuous operation, finishing to lines and grades as directed by Engineer-in-charge and curing by curing compound /by providing cement vata in cement Mortar 1:8 @0.6 metre X 0.6 metre centre to centre, admeasuring 80 mili metre at bottom and 40 mili metre at top with depth of 75 mili metre and maintaining the same throughout curing period by any other method approved by Engineer-in-charge.

45

-

6925.37

... More
Cutting transverse contraction joints 3 to 4 mili metre wide and depth 60 mili metre .in concrete slab using concrete cutting machine with diamond studded saw within 48 hours of casting of bay / slab etcetera complete including subsequent widening of the groove 8 to 10 mili metre wide at top having depth of 15 mili metre as directed by Engineer incharge.

100

-

71.76

... More
VQCC Testing Charges

-

-

-

... More
Finness Modulas (Sieve Analysis), Silt Content & Clay Content

1

-

1200

... More
Water Absorption, Specific Gravity, Impact Value, Crushing Value

1

-

2300

... More
Sieve Analysis for Metal

1

-

600

... More
Compressive Strength of Cement Concrete Cube (Set of 3 Cubes)

5

-

600

... More
Royalty Charges

99.23

-

141.34

... More
6% Central Goods Services & Tax + 6% State Goods Services & Tax

418010

-

0.12

... More
35] Constg. of C.C. Drain from Akhade to Bangar @ Beed Tq. Beed

-

-

-

... More
Excavation for catch / side water gutter in all sorts of soils to the specified section including stacking the excavated stuff in a regular bund and disposing of unsuitable or excess stuff as directed all sorts of soils.

139.32

-

75.86

... More
Construction of granular sub-base by providing close graded Material, mixing in a mechanical mix plant at Optimum Moisture Content, carriage of mixed Material to work site, spreading in uniform layers with motor grader/ Paver on prepared surface and compacting with vibratory roller to achieve the desired density, complete as per clause 401 -- Plant Mix Method and Grading - I Material

23.22

-

2048.95

... More
Providing and laying Cast in situ/Ready Mix cement concrete in M-15 of trap/ granite/quartzite/gneiss metal for bed blocks, foundation blocks and such other items including bailing out water, Steel centering, formwork, laying/ pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etcetera complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etcetera (Wooden centering will not be allowed.), with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etcetera complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etcetera)

66.42

-

6170.02

... More
VQCC Testing Charges

-

-

-

... More
Finness Modulas (Sieve Analysis), Silt Content & Clay Content

1

-

1200

... More
Water Absorption, Specific Gravity, Impact Value, Crushing Value

1

-

2300

... More
Royalty Charges

29.43

-

141.34

... More
6% Central Goods Services & Tax + 6% State Goods Services & Tax

467958

-

0.12

... More
36] Constg. of C.C. Road & Drain from Sabunkar to Kavchankar @ Beed Tq. Beed

-

-

-

... More
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing to proper grade and camber, applying and brooming requisite type of screening/ binding Materials to fill up the interstices of coarse aggregate, watering and compacting with Vibratory roller. to the required density. By Mechanical Means - Grading I (Using Screening Type A (13.2) mili metre Aggregate)

45

-

2065.62

... More
Providing and laying 125 micron Low Density Polyethylene (LDPE) sheet Confirming to Indian Standard 3395 : 1997 below concrete pavement including all materials and labour complete.

300

-

20.8

... More
Providing and laying in-situ M-30 Grade unreinforced plain cement concrete pavement over a prepared sub base with 43 grade cement, coarse and fine aggregate( natural sand/ VSI grade finely washed crushed sand) conforming to IS 383, using fine and coarse aggregates combined gradation as per Table 600-3 of MORTH Specification 2013, mixed in a batching and mixing plant/ non tilting mixer and Weigh batcher as per approved mix design, admixtures, transporting to site, spreading, laying with approved make paver, compacted and finished in a continuous operation, finishing to lines and grades as directed by Engineer-in-charge and curing by curing compound /by providing cement vata in cement Mortar 1:8 @0.6 metre X 0.6 metre centre to centre, admeasuring 80 mili metre at bottom and 40 mili metre at top with depth of 75 mili metre and maintaining the same throughout curing period by any other method approved by Engineer-in-charge.

45

-

6925.37

... More
Cutting transverse contraction joints 3 to 4 mili metre wide and depth 60 mili metre .in concrete slab using concrete cutting machine with diamond studded saw within 48 hours of casting of bay / slab etcetera complete including subsequent widening of the groove 8 to 10 mili metre wide at top having depth of 15 mili metre as directed by Engineer incharge.

100

-

71.76

... More
Excavation for catch / side water gutter in all sorts of soils to the specified section including stacking the excavated stuff in a regular bund and disposing of unsuitable or excess stuff as directed all sorts of soils.

77.4

-

75.86

... More
Construction of granular sub-base by providing close graded Material, mixing in a mechanical mix plant at Optimum Moisture Content, carriage of mixed Material to work site, spreading in uniform layers with motor grader/ Paver on prepared surface and compacting with vibratory roller to achieve the desired density, complete as per clause 401 -- Plant Mix Method and Grading - I Material

12.9

-

2048.95

... More
Providing and laying Cast in situ/Ready Mix cement concrete in M-15 of trap/ granite/quartzite/gneiss metal for bed blocks, foundation blocks and such other items including bailing out water, Steel centering, formwork, laying/ pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etcetera complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etcetera (Wooden centering will not be allowed.), with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etcetera complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etcetera)

36.9

-

6170.02

... More
VQCC Testing Charges

-

-

-

... More
Finness Modulas (Sieve Analysis), Silt Content & Clay Content

1

-

1200

... More
Water Absorption, Specific Gravity, Impact Value, Crushing Value

1

-

2300

... More
Sieve Analysis for Metal

1

-

600

... More
Compressive Strength of Cement Concrete Cube (Set of 3 Cubes)

5

-

600

... More
Royalty Charges

116.11

-

141.34

... More
6% Central Goods Services & Tax + 6% State Goods Services & Tax

677987

-

0.12

... More
37] Constg. of C.C. Road from Janabai Thorat to Radhakisan Raut @ Beed Tq. Beed

-

-

-

... More
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing to proper grade and camber, applying and brooming requisite type of screening/ binding Materials to fill up the interstices of coarse aggregate, watering and compacting with Vibratory roller. to the required density. By Mechanical Means - Grading I (Using Screening Type A (13.2) mili metre Aggregate)

20.25

-

2065.62

... More
Providing and laying 125 micron Low Density Polyethylene (LDPE) sheet Confirming to Indian Standard 3395 : 1997 below concrete pavement including all materials and labour complete.

135

-

20.8

... More
Providing and laying in-situ M-30 Grade unreinforced plain cement concrete pavement over a prepared sub base with 43 grade cement, coarse and fine aggregate( natural sand/ VSI grade finely washed crushed sand) conforming to IS 383, using fine and coarse aggregates combined gradation as per Table 600-3 of MORTH Specification 2013, mixed in a batching and mixing plant/ non tilting mixer and Weigh batcher as per approved mix design, admixtures, transporting to site, spreading, laying with approved make paver, compacted and finished in a continuous operation, finishing to lines and grades as directed by Engineer-in-charge and curing by curing compound /by providing cement vata in cement Mortar 1:8 @0.6 metre X 0.6 metre centre to centre, admeasuring 80 mili metre at bottom and 40 mili metre at top with depth of 75 mili metre and maintaining the same throughout curing period by any other method approved by Engineer-in-charge.

27

-

6925.37

... More
Cutting transverse contraction joints 3 to 4 mili metre wide and depth 60 mili metre .in concrete slab using concrete cutting machine with diamond studded saw within 48 hours of casting of bay / slab etcetera complete including subsequent widening of the groove 8 to 10 mili metre wide at top having depth of 15 mili metre as directed by Engineer incharge.

45

-

71.76

... More
VQCC Testing Charges

-

-

-

... More
Finness Modulas (Sieve Analysis), Silt Content & Clay Content

1

-

1200

... More
Water Absorption, Specific Gravity, Impact Value, Crushing Value

1

-

2300

... More
Sieve Analysis for Metal

1

-

600

... More
Compressive Strength of Cement Concrete Cube (Set of 3 Cubes)

3

-

600

... More
Royalty Charges

51.37

-

141.34

... More
6% Central Goods Services & Tax + 6% State Goods Services & Tax

234851

-

0.12

... More
38] Constg. of C.C. Drain from Andhure to Bansode @ Beed Tq. Beed

-

-

-

... More
Excavation for catch / side water gutter in all sorts of soils to the specified section including stacking the excavated stuff in a regular bund and disposing of unsuitable or excess stuff as directed all sorts of soils.

54.18

-

75.86

... More
Construction of granular sub-base by providing close graded Material, mixing in a mechanical mix plant at Optimum Moisture Content, carriage of mixed Material to work site, spreading in uniform layers with motor grader/ Paver on prepared surface and compacting with vibratory roller to achieve the desired density, complete as per clause 401 -- Plant Mix Method and Grading - I Material

9.03

-

2048.95

... More
Providing and laying Cast in situ/Ready Mix cement concrete in M-15 of trap/ granite/quartzite/gneiss metal for bed blocks, foundation blocks and such other items including bailing out water, Steel centering, formwork, laying/ pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etcetera complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etcetera (Wooden centering will not be allowed.), with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etcetera complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etcetera)

25.83

-

6170.02

... More
VQCC Testing Charges

-

-

-

... More
Finness Modulas (Sieve Analysis), Silt Content & Clay Content

1

-

1200

... More
Water Absorption, Specific Gravity, Impact Value, Crushing Value

1

-

2300

... More
Royalty Charges

12.18

-

141.34

... More
6% Central Goods Services & Tax + 6% State Goods Services & Tax

181983

-

0.12

... More
39] Constg. of C.C. Drain from Mane Kirana to Pream Jadhav @ Beed Tq. Beed

-

-

-

... More
Excavation for catch / side water gutter in all sorts of soils to the specified section including stacking the excavated stuff in a regular bund and disposing of unsuitable or excess stuff as directed all sorts of soils.

100.62

-

75.86

... More
Construction of granular sub-base by providing close graded Material, mixing in a mechanical mix plant at Optimum Moisture Content, carriage of mixed Material to work site, spreading in uniform layers with motor grader/ Paver on prepared surface and compacting with vibratory roller to achieve the desired density, complete as per clause 401 -- Plant Mix Method and Grading - I Material

16.77

-

2048.95

... More
Providing and laying Cast in situ/Ready Mix cement concrete in M-15 of trap/ granite/quartzite/gneiss metal for bed blocks, foundation blocks and such other items including bailing out water, Steel centering, formwork, laying/ pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etcetera complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etcetera (Wooden centering will not be allowed.), with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etcetera complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etcetera)

47.97

-

6170.02

... More
VQCC Testing Charges

-

-

-

... More
Finness Modulas (Sieve Analysis), Silt Content & Clay Content

1

-

1200

... More
Water Absorption, Specific Gravity, Impact Value, Crushing Value

1

-

2300

... More
Royalty Charges

21.59

-

141.34

... More
6% Central Goods Services & Tax + 6% State Goods Services & Tax

337970

-

0.12

... More
40] Constg. of C.C. Road & Drain from Gaisamodre House to Paradise Hospital via Taufiq's House, Masarrat Nagar, Ward No.02 @ Beed Tq. Beed

-

-

-

... More
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing to proper grade and camber, applying and brooming requisite type of screening/ binding Materials to fill up the interstices of coarse aggregate, watering and compacting with Vibratory roller. to the required density. By Mechanical Means - Grading I (Using Screening Type A (13.2) mili metre Aggregate)

22.5

-

2082.18

... More
Providing and laying 125 micron Low Density Polyethylene (LDPE) sheet Confirming to Indian Standard 3395 : 1997 below concrete pavement including all materials and labour complete.

750

-

20.78

... More
Providing and laying in-situ M-30 Grade unreinforced plain cement concrete pavement over a prepared sub base with 43 grade cement, coarse and fine aggregate( natural sand/ VSI grade finely washed crushed sand) conforming to IS 383, using fine and coarse aggregates combined gradation as per Table 600-3 of MORTH Specification 2013, mixed in a batching and mixing plant/ non tilting mixer and Weigh batcher as per approved mix design, admixtures, transporting to site, spreading, laying with approved make paver, compacted and finished in a continuous operation, finishing to lines and grades as directed by Engineer-in-charge and curing by curing compound /by providing cement vata in cement Mortar 1:8 @0.6 metre X 0.6 metre centre to centre, admeasuring 80 mili metre at bottom and 40 mili metre at top with depth of 75 mili metre and maintaining the same throughout curing period by any other method approved by Engineer-in-charge.

112.5

-

6925.37

... More
Cutting transverse contraction joints 3 to 4 mili metre wide and depth 60 mili metre .in concrete slab using concrete cutting machine with diamond studded saw within 48 hours of casting of bay / slab etcetera complete including subsequent widening of the groove 8 to 10 mili metre wide at top having depth of 15 mili metre as directed by Engineer incharge.

250

-

71.68

... More
Excavation for catch / side water gutter in all sorts of soils to the specified section including stacking the excavated stuff in a regular bund and disposing of unsuitable or excess stuff as directed all sorts of soils.

116.1

-

75.86

... More
Construction of granular sub-base by providing close graded Material, mixing in a mechanical mix plant at Optimum Moisture Content, carriage of mixed Material to work site, spreading in uniform layers with motor grader/ Paver on prepared surface and compacting with vibratory roller to achieve the desired density, complete as per clause 401 -- Plant Mix Method and Grading - I Material

19.35

-

2048.95

... More
Providing and laying Cast in situ/Ready Mix cement concrete in M-15 of trap/ granite/quartzite/gneiss metal for bed blocks, foundation blocks and such other items including bailing out water, Steel centering, formwork, laying/ pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etcetera complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etcetera (Wooden centering will not be allowed.), with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etcetera complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etcetera)

55.35

-

6093.3

... More
VQCC Testing Charges

-

-

-

... More
Finness Modulas (Sieve Analysis), Silt Content & Clay Content

3

-

1200

... More
Water Absorption, Specific Gravity, Impact Value, Crushing Value

3

-

2300

... More
Sieve Analysis for Metal

1

-

600

... More
Compressive Strength of Cement Concrete Cube (Set of 3 Cubes)

20

-

600

... More
Royalty Charges

163.89

-

141.34

... More
6% Central Goods Services & Tax + 6% State Goods Services & Tax

1245176

-

0.12

... More
41] Constg. of C.C. Road & Drain from Janore's Hospital to Siddiqui's House via Majed's House @ Beed Tq. Beed

-

-

-

... More
Excavation for roadway in earth, soil of all sorts, sand, gravel or soft murum including dressing section to the required grade, camber and side slopes and conveying the excavated materials with all lifts upto a lead of 50 metre and spreading for embankment or stacking as directed. By Manual Means. (with prior permission of S.E.)

56.25

-

250.35

... More
Construction of granular sub-base by providing close graded Material, mixing in a mechanical mix plant at Optimum Moisture Content, carriage of mixed Material to work site, spreading in uniform layers with motor grader / Paver on prepared surface and compacting with vibratory roller to achieve the desired density, complete as per clause 401 -- Plant Mix Method and Grading - II Material

37.5

-

2254.21

... More
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing to proper grade and camber, applying and brooming requisite type of screening/ binding Materials to fill up the interstices of coarse aggregate, watering and compacting with Vibratory roller. to the required density. By Mechanical Means - Grading I (Using Screening Type A (13.2) mili metre Aggregate)

28.13

-

2081.58

... More
Providing and laying 125 micron Low Density Polyethylene (LDPE) sheet Confirming to Indian Standard 3395 : 1997 below concrete pavement including all materials and labour complete.

375

-

20.78

... More
Providing and laying in-situ M-30 Grade unreinforced plain cement concrete pavement over a prepared sub base with 43 grade cement, coarse and fine aggregate( natural sand/ VSI grade finely washed crushed sand) conforming to IS 383, using fine and coarse aggregates combined gradation as per Table 600-3 of MORTH Specification 2013, mixed in a batching and mixing plant/ non tilting mixer and Weigh batcher as per approved mix design, admixtures, transporting to site, spreading, laying with approved make paver, compacted and finished in a continuous operation, finishing to lines and grades as directed by Engineer-in-charge and curing by curing compound /by providing cement vata in cement Mortar 1:8 @0.6 metre X 0.6 metre centre to centre, admeasuring 80 mili metre at bottom and 40 mili metre at top with depth of 75 mili metre and maintaining the same throughout curing period by any other method approved by Engineer-in-charge.

56.25

-

6925.37

... More
Excavation for catch / side water gutter in all sorts of soils to the specified section including stacking the excavated stuff in a regular bund and disposing of unsuitable or excess stuff as directed all sorts of soils.

58.05

-

75.86

... More
Construction of granular sub-base by providing close graded Material, mixing in a mechanical mix plant at Optimum Moisture Content, carriage of mixed Material to work site, spreading in uniform layers with motor grader/ Paver on prepared surface and compacting with vibratory roller to achieve the desired density, complete as per clause 401 -- Plant Mix Method and Grading - I Material

9.68

-

2048.95

... More
Providing and laying Cast in situ/Ready Mix cement concrete in M-15 of trap/ granite/quartzite/gneiss metal for bed blocks, foundation blocks and such other items including bailing out water, Steel centering, formwork, laying/ pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etcetera complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etcetera (Wooden centering will not be allowed.), with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etcetera complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etcetera)

27.68

-

6093.3

... More
Cutting transverse contraction joints 3 to 4 mili metre wide and depth 60 mili metre .in concrete slab using concrete cutting machine with diamond studded saw within 48 hours of casting of bay / slab etcetera complete including subsequent widening of the groove 8 to 10 mili metre wide at top having depth of 15 mili metre as directed by Engineer incharge.

125

-

71.68

... More
VQCC Testing Charges

-

-

-

... More
Finness Modulas (Sieve Analysis), Silt Content & Clay Content

3

-

1200

... More
Water Absorption, Specific Gravity, Impact Value, Crushing Value

3

-

2300

... More
Sieve Analysis for Metal

1

-

600

... More
Compressive Strength of Cement Concrete Cube (Set of 3 Cubes)

20

-

600

... More
Royalty Charges

102.96

-

141.34

... More
6% Central Goods Services & Tax + 6% State Goods Services & Tax

756365

-

0.12

... More
42] Constg. of C.C. Road & Drain from Sasane's House to Ashok Talle's House, Ward No.02 @ Beed Tq. Beed

-

-

-

... More
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing to proper grade and camber, applying and brooming requisite type of screening/ binding Materials to fill up the interstices of coarse aggregate, watering and compacting with Vibratory roller. to the required density. By Mechanical Means - Grading I (Using Screening Type A (13.2) mili metre Aggregate)

56.25

-

2082.18

... More
Providing and laying 125 micron Low Density Polyethylene (LDPE) sheet Confirming to Indian Standard 3395 : 1997 below concrete pavement including all materials and labour complete.

750

-

20.78

... More
Providing and laying in-situ M-30 Grade unreinforced plain cement concrete pavement over a prepared sub base with 43 grade cement, coarse and fine aggregate( natural sand/ VSI grade finely washed crushed sand) conforming to IS 383, using fine and coarse aggregates combined gradation as per Table 600-3 of MORTH Specification 2013, mixed in a batching and mixing plant/ non tilting mixer and Weigh batcher as per approved mix design, admixtures, transporting to site, spreading, laying with approved make paver, compacted and finished in a continuous operation, finishing to lines and grades as directed by Engineer-in-charge and curing by curing compound /by providing cement vata in cement Mortar 1:8 @0.6 metre X 0.6 metre centre to centre, admeasuring 80 mili metre at bottom and 40 mili metre at top with depth of 75 mili metre and maintaining the same throughout curing period by any other method approved by Engineer-in-charge.

112.5

-

6925.37

... More
Excavation for catch / side water gutter in all sorts of soils to the specified section including stacking the excavated stuff in a regular bund and disposing of unsuitable or excess stuff as directed all sorts of soils.

116.1

-

75.86

... More
Construction of granular sub-base by providing close graded Material, mixing in a mechanical mix plant at Optimum Moisture Content, carriage of mixed Material to work site, spreading in uniform layers with motor grader/ Paver on prepared surface and compacting with vibratory roller to achieve the desired density, complete as per clause 401 -- Plant Mix Method and Grading - I Material

19.35

-

2048.95

... More
Providing and laying Cast in situ/Ready Mix cement concrete in M-15 of trap/ granite/quartzite/gneiss metal for bed blocks, foundation blocks and such other items including bailing out water, Steel centering, formwork, laying/ pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etcetera complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etcetera (Wooden centering will not be allowed.), with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etcetera complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etcetera)

55.35

-

6093.3

... More
Cutting transverse contraction joints 3 to 4 mili metre wide and depth 60 mili metre .in concrete slab using concrete cutting machine with diamond studded saw within 48 hours of casting of bay / slab etcetera complete including subsequent widening of the groove 8 to 10 mili metre wide at top having depth of 15 mili metre as directed by Engineer incharge.

250

-

71.68

... More
VQCC Testing Charges

-

-

-

... More
Finness Modulas (Sieve Analysis), Silt Content & Clay Content

3

-

1200

... More
Water Absorption, Specific Gravity, Impact Value, Crushing Value

3

-

2300

... More
Sieve Analysis for Metal

1

-

600

... More
Compressive Strength of Cement Concrete Cube (Set of 3 Cubes)

20

-

600

... More
Royalty Charges

204.72

-

141.34

... More
6% Central Goods Services & Tax + 6% State Goods Services & Tax

1315450

-

0.12

... More
43] Constg. of C.C. Road & Drain from Apna Kirana to Aabeda Masjid via Abdus Salam Seth House, Ward No.02 @ Beed Tq. Beed

-

-

-

... More
Excavation for roadway in earth, soil of all sorts, sand, gravel or soft murum including dressing section to the required grade, camber and side slopes and conveying the excavated materials with all lifts upto a lead of 50 metre and spreading for embankment or stacking as directed. By Manual Means. (with prior permission of S.E.)

45

-

250.35

... More
Construction of granular sub-base by providing close graded Material, mixing in a mechanical mix plant at Optimum Moisture Content, carriage of mixed Material to work site, spreading in uniform layers with motor grader / Paver on prepared surface and compacting with vibratory roller to achieve the desired density, complete as per clause 401 -- Plant Mix Method and Grading - II Material

30

-

2254.21

... More
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing to proper grade and camber, applying and brooming requisite type of screening/ binding Materials to fill up the interstices of coarse aggregate, watering and compacting with Vibratory roller. to the required density. By Mechanical Means - Grading I (Using Screening Type A (13.2) mili metre Aggregate)

22.5

-

2081.58

... More
Providing and laying 125 micron Low Density Polyethylene (LDPE) sheet Confirming to Indian Standard 3395 : 1997 below concrete pavement including all materials and labour complete.

300

-

20.78

... More
Providing and laying in-situ M-30 Grade unreinforced plain cement concrete pavement over a prepared sub base with 43 grade cement, coarse and fine aggregate( natural sand/ VSI grade finely washed crushed sand) conforming to IS 383, using fine and coarse aggregates combined gradation as per Table 600-3 of MORTH Specification 2013, mixed in a batching and mixing plant/ non tilting mixer and Weigh batcher as per approved mix design, admixtures, transporting to site, spreading, laying with approved make paver, compacted and finished in a continuous operation, finishing to lines and grades as directed by Engineer-in-charge and curing by curing compound /by providing cement vata in cement Mortar 1:8 @0.6 metre X 0.6 metre centre to centre, admeasuring 80 mili metre at bottom and 40 mili metre at top with depth of 75 mili metre and maintaining the same throughout curing period by any other method approved by Engineer-in-charge.

45

-

6925.37

... More
Excavation for catch / side water gutter in all sorts of soils to the specified section including stacking the excavated stuff in a regular bund and disposing of unsuitable or excess stuff as directed all sorts of soils.

46.44

-

75.86

... More
Construction of granular sub-base by providing close graded Material, mixing in a mechanical mix plant at Optimum Moisture Content, carriage of mixed Material to work site, spreading in uniform layers with motor grader/ Paver on prepared surface and compacting with vibratory roller to achieve the desired density, complete as per clause 401 -- Plant Mix Method and Grading - I Material

7.74

-

2048.95

... More
Providing and laying Cast in situ/Ready Mix cement concrete in M-15 of trap/ granite/quartzite/gneiss metal for bed blocks, foundation blocks and such other items including bailing out water, Steel centering, formwork, laying/ pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etcetera complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etcetera (Wooden centering will not be allowed.), with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etcetera complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etcetera)

22.14

-

6093.3

... More
Cutting transverse contraction joints 3 to 4 mili metre wide and depth 60 mili metre .in concrete slab using concrete cutting machine with diamond studded saw within 48 hours of casting of bay / slab etcetera complete including subsequent widening of the groove 8 to 10 mili metre wide at top having depth of 15 mili metre as directed by Engineer incharge.

100

-

71.68

... More
VQCC Testing Charges

-

-

-

... More
Finness Modulas (Sieve Analysis), Silt Content & Clay Content

3

-

1200

... More
Water Absorption, Specific Gravity, Impact Value, Crushing Value

3

-

2300

... More
Sieve Analysis for Metal

1

-

600

... More
Compressive Strength of Cement Concrete Cube (Set of 3 Cubes)

20

-

600

... More
Royalty Charges

82.61

-

141.34

... More
6% Central Goods Services & Tax + 6% State Goods Services & Tax

605060

-

0.12

... More
44] Constg. of C.C. Road & Drain from Jadhav's House to Gujrati Colony, Ward No.02 @ Beed Tq. Beed

-

-

-

... More
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing to proper grade and camber, applying and brooming requisite type of screening/ binding Materials to fill up the interstices of coarse aggregate, watering and compacting with Vibratory roller. to the required density. By Mechanical Means - Grading I (Using Screening Type A (13.2) mili metre Aggregate)

11.25

-

2082.18

... More
Providing and laying 125 micron Low Density Polyethylene (LDPE) sheet Confirming to Indian Standard 3395 : 1997 below concrete pavement including all materials and labour complete.

750

-

20.78

... More
Providing and laying in-situ M-30 Grade unreinforced plain cement concrete pavement over a prepared sub base with 43 grade cement, coarse and fine aggregate( natural sand/ VSI grade finely washed crushed sand) conforming to IS 383, using fine and coarse aggregates combined gradation as per Table 600-3 of MORTH Specification 2013, mixed in a batching and mixing plant/ non tilting mixer and Weigh batcher as per approved mix design, admixtures, transporting to site, spreading, laying with approved make paver, compacted and finished in a continuous operation, finishing to lines and grades as directed by Engineer-in-charge and curing by curing compound /by providing cement vata in cement Mortar 1:8 @0.6 metre X 0.6 metre centre to centre, admeasuring 80 mili metre at bottom and 40 mili metre at top with depth of 75 mili metre and maintaining the same throughout curing period by any other method approved by Engineer-in-charge.

112.5

-

6925.37

... More
Cutting transverse contraction joints 3 to 4 mili metre wide and depth 60 mili metre .in concrete slab using concrete cutting machine with diamond studded saw within 48 hours of casting of bay / slab etcetera complete including subsequent widening of the groove 8 to 10 mili metre wide at top having depth of 15 mili metre as directed by Engineer incharge.

250

-

71.68

... More
Excavation for catch / side water gutter in all sorts of soils to the specified section including stacking the excavated stuff in a regular bund and disposing of unsuitable or excess stuff as directed all sorts of soils.

116.1

-

75.86

... More
Construction of granular sub-base by providing close graded Material, mixing in a mechanical mix plant at Optimum Moisture Content, carriage of mixed Material to work site, spreading in uniform layers with motor grader/ Paver on prepared surface and compacting with vibratory roller to achieve the desired density, complete as per clause 401 -- Plant Mix Method and Grading - I Material

19.35

-

2048.95

... More
Providing and laying Cast in situ/Ready Mix cement concrete in M-15 of trap/ granite/quartzite/gneiss metal for bed blocks, foundation blocks and such other items including bailing out water, Steel centering, formwork, laying/ pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etcetera complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etcetera (Wooden centering will not be allowed.), with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etcetera complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etcetera)

55.35

-

6093.3

... More
VQCC Testing Charges

-

-

-

... More
Finness Modulas (Sieve Analysis), Silt Content & Clay Content

3

-

1200

... More
Water Absorption, Specific Gravity, Impact Value, Crushing Value

3

-

2300

... More
Sieve Analysis for Metal

1

-

600

... More
Compressive Strength of Cement Concrete Cube (Set of 3 Cubes)

20

-

600

... More
Royalty Charges

150.27

-

141.34

... More
6% Central Goods Services & Tax + 6% State Goods Services & Tax

1221752

-

0.12



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.