Directorate Of Construction Services And Estate Management Tender

Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.

Directorate Of Construction Services And Estate Management - DCSEM Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date7 Oct 2024
Closing Date4 Nov 2024
Tender Amount₹ 1,47,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
DISTRIBUTION BOARDS:

-

-

-

... More
Supply, installation, testing & commissioning of ready made Distribution Boards fabricated & wired made of MSCRCA sheet with double door meeting with IP-42 degree of protection painted with seven tank metal treatment process, stove enameled, approved colour all as per specifications, standards, drawings & instruction of E.I.C. Note: Following works also includes in agency scope: (1) MCB,s shall be min 10 KA breaking capacity (type C) except 2 A MCBS that may be type D. 2) Blanking plates shall be included in the scope of work. (3) Door frame and door earthing shall be provided. (4) All fabrication and GA drawings shall be got approved by Department.. (5) Lags, feruling, marking of MCB, fixing of denger plates in Top of the service Box etc. . (6) Circuit distribution diagram in laminated sheet shall be fix inside of service box.

-

-

-

... More
Concealed flat TPN DB (6 way out going) consisting of the following :. a) 32 A 4 pole RCBO with 30 mA sensitivity – 1No. b) 6-32A SP MCB --18Nos c) 30 A, 12 Way (brass Neutral link) ---2 Set. d) 12 Way Brass Earthing link .....2 Sets.

6

-

-

... More
Supply, installation, testing & commissioning of 63A FP 300mA sensitivity RCBO with powder coated enclosure, all as per specifications, standards, drawings & instruction of E.I.C.

2

-

-

... More
Supply, installation, testing & commissioning of 6A DP 30mA sensitivity RCBO with powder coated enclosure, all as per specifications, standards, drawings & instruction of E.I.C.

2

-

-

... More
Supply Installation, testing & commissioning of DB accessories in existing DB Enclouser (DB Configuration: 6 way outgoing TPN DB of Legrand make). All as per specifications, standards, drawings & instruction of E.I.C. Note: Following works also includes in agency scope: (1) Supply of DB internal components with readymade interconnection wiring set is included in agency scope. (2) Blanking plates required shall be in included in agency scope. (3) DB door earthing,Lags, feruling, marking of MCB, fixing of Denger plates in Top DB is included in agency scope.. (4) DB circuit distribution diagram in laminated sheet shall be fixed inside DB is included in agency scope.

-

-

-

... More
Concealed flat TPN DB (6 way outgoing) consisting of the following : a) 32 A 4 pole RCBO with 30 mA sensitivity – 1No. b) 2-20A SP MCB - 18Nos. c) 30 A. 12 Way (brass Neutral Link) - 1 Set. d) 12 Way Brass Earthing link -2 Sets.

33

-

-

... More
Installation, testing & commissioning of DB accessories in existing DB enclouser , all as per specifications, standards, drawings & instruction of E.I.C. (DB Configuration: 6 way outgoing TPN DB of Legrand make): 1) To be supplied by Agency in this scope:- a)32 A 4 pole RCBO with 30 mA sensitivity – 1No. 2)Department supply component( Free issue material) :- a)2-20A SP MCB --18Nos. b) 30 A. 12 Way (brass Neutral Link) ---1 Set. c)12 Way Brass Earthing link .....2 Sets. d)Readymade Interconnection wire -1Sets. e) DB enclouser Following works also includes in agency scope: (1) Blanking plates required shall be in included in agency scope. (2) DB door earthing,Lags, feruling, marking of MCB, fixing of Danger plates in Top DB is included in agency scope.. (3) DB circuit distribution diagram in laminated sheet shall be fixed inside DB is included in agency scope.

4

-

-

... More
Installation, testing & commissioning of DB with accessories , all as per specifications, standards, drawings & instruction of E.I.C. (DB Configuration: 6 way outgoing TPN DB of Legrand make): 1) To be supplied by Agency in this scope a)32 A 4 pole RCBO with 30 mA sensitivity – 1No. 2) Department supply components ( Free issue material):- a)DB enclouser with cover.. b)2-20A SP MCB -18Nos. c) 30 A. 12 Way (brass Neutral Link) - 1 Set. d)12 Way Brass Earthing link - 2 Sets. e)Readymade Interconnection wire -1Sets Following works also includes in agency scope: (1) Blanking plates required shall be in included in agency scope. (2) DB door earthing,Lags, feruling, marking of MCB, fixing of Danger plates in Top DB is included in agency scope. (3) DB circuit distribution diagram in laminated sheet shall be fixed inside DB is included in agency scope.

15

-

-

... More
Installation, testing & commissioning of DB with accessories , all as per specifications, standards, drawings & instruction of E.I.C. (DB Configuration: 6 way outgoing TPN DB of Legrand make): 1)To be supplied by Agency in this scope:- a)25A 2 pole RCBO with 30 mA sensitivity –1No. 2)Department supply components ( Free issue material):- a)DB enclouser with cover. b)6-16A SP MCB --10 Nos.. c) 30 A. 12 Way (brass Neutral Link)-1 Set. d)12 Way Brass Earthing link .....1 Sets. e)Readymade Interconnection wire -1Sets Following works also includes in agency scope: (1) Blanking plates required shall be in included in agency scope. (2) DB door earthing,Lags, feruling, marking of MCB, fixing of Danger plates in Top DB is included in agency scope. (3) DB circuit distribution diagram in laminated sheet shall be fixed inside DB is included in agency scope.

3

-

-

... More
Installation, testing & commissioning of DB with accessories , all as per specifications, standards, drawings & instruction of E.I.C. (DB Configuration: 6 way outgoing TPN DB of Legrand make): 1)To be supplied by Agency in this scope:- a)32 A 4 pole RCBO with 30 mA sensitivity – 1No. 2)Department supply components ( Free issue material):- a)DB enclouser with cover. b)2-16A SP MCB --12Nos. c) 30 A. 12 Way (brass Neutral Link) ---2 Set. d)12 Way Brass Earthing link ..................1 Sets. e)Readymade Interconnection wire -1Sets Following works also includes in agency scope: (1) Blanking plates required shall be in included in agency scope. (2) DB door earthing,Lags, feruling, marking of MCB, fixing of Danger plates in Top DB is included in agency scope. (3) DB circuit distribution diagram in laminated sheet shall be fixed inside DB is included in agency scope.

1

-

-

... More
Installation, testing & commissioning of 16/20 A DP MCB ( 10 KA), 230 V, 12 A, AC3 dutycontactor, timer, Auto / manual toggle switch is housed in a MS box enclosure with wire way box made out of 16 SWG thick MS CRCA sheet with removable front cover for security light control.All as per specifications, drawings & instruction of E-I-C. DP MCB with enclousre & wire-way box will be supplied by Department. Note: Following work also includes in agency scope: (1) Required MS Angle/Channel support for enclosure & other accessories are in scope of contractor.

1

-

-

... More
RISING MAINS: Installation, Testing & Commissioning of readymade 415 V, 50Hz triple pole & neutral totally enclosed, IP 54, indoor mounting, 1.6mm GI sheet steel clad, powder coated, sections with compact air insulated type, tinned Cu bus bar rising main section having following configuration requirements: a) Bus bar : 3 Phase + neutral tinned Cu bus bar.Neutral shall have 100% capacity. b) Symmetrical short circuit rating : 25 KA at 415V. c) Provision of two taps/floor/shaft d) Bus bar current rating : 300 A Rising mains with components will be supplied by Department. Note: Following works also includes in agency scope: (1) Necessary installation accessories are the part of agency scope. (2)The rising main shall be complete with necessary support arrangement on each floor including provision for thermal expansion and contraction etc. (3) Fire barrier shall be provided on each floor. (4) Any components/features etc not specifically mentioned but which are required functionally & for safety of system shall be inlcuded in scope of work without extra financial implication. (5)The rising main shall be complete with following components / accessories.

-

-

-

... More
End feed unit with 250A 4 pole MCCB with thermal magnetic release and rotary handle.

2

-

-

... More
300 A, air insulated, 3 phase + neutral copper conductor Straight feeder section Note : Each shaft shall have two feeder sections i.e. 1st upto 9th floor and another from 10th floor to 18th floor.

49

-

-

... More
63A tap off box with 63 A TP MCCB

18

-

-

... More
End Cover

2

-

-

... More
Sub-Main Wiring in existing Conduit for common area DBs & Flat DBs: Supply, installation, testing & commissioning of 650/1100 V grade IS 694 mark multistranded copper conductor FRLS PVC insulated wires in existing heavy duty M.S ERW/ HMS PVC conduit concealed in slab/wall. Termination on both ends with crimping tinned copper sockets Necessary leads to be provided at both ends. All as per drawing, specifications & as per instructions of E-I-C. Note:- Following works also includes in agency scope: (1) Proper size Rubber Grommet shall be used in every junction box/ DB/Switch Board & MS counduits for privent demeged of electrical wire during wire pulling work. (2) Lugs, ferruling for circuit identification shall be includes in agency scope.

-

-

-

... More
4 nos of 10 sq.mm wires in existing 32 mm dia conduit with 2 nos. 6 sq.mm earth wire.

1500

-

-

... More
2 nos. of 2.5 sq.mm wires in existing 25 mm dia conduit with 1 no. of 2.5 sq. mm earth wire.

300

-

-

... More
Point wiring in the existing Concealed/Surface HGERW Conduit System: Supply Installation, testing & commissioning of Point wiring of 3-wire system (Circuit) for light/ceiling fan/Exhaust fan/wall mounted fan /6A/16A/ 6+16 socket outlet /AC/MCB, water heater point, bell pt.with PVC insulated FRLS multistranded copper conductor wires, in existing 25 to 38mm dia. HG ERW conduit concealed/ exposed in slab/wall . Scope also includes, clearing of conduit by pulling fish wire, rubber bushing etc. for pulling of wire as required in existing conduit, brass/bakelite (straight/angular) lamp holders, 3 plate ceiling rose/3 core/twin flexible copper chords, connectors, etc. as per specifications & drawings and as per instructions of Engineer-in-charge & as detailed below: Note:-Switch/socket and Fan Regulator with modular plates will be supplied by department. Note:-Following works also includes in agency scope:- (1) Point wiring means 3-wire system (Circuit) includes from DB to Switch Board and switch board to Light/ceiling fan/Exhaust fan/wall mounted fan /6A/16A/6+16 socket outlet /AC/MCB, water heater point,bell pt. is to be included in point wiring works. (2) Connections shall be done with crimped type tinned copper lugs & washers. (3) Wire marking(ferrule) used each end of point wiring circuits are included in agency scope.

-

-

-

... More
In passage/staicase/stilt/lift loby/ lift machine room/electrical room etc.

-

-

-

... More
Primary light point with 2 Nos of 1.5 sq.mm. wires and 2.5 sq.mm Earth wire , 230 V, 6A switch.

173

-

-

... More
Secondary point looped to above with 2 Nos of 1.5 sq.mm and 2.5 sqmm Earth wires.

58

-

-

... More
6A/16 A combined socket outlet pt with 3 Nos of 2.5 sq.mm wires complete with 16 A switch in one box.

4

-

-

... More
Point wiring for single phase exhaust fan with 3 Nos of 2.5 sq.mm wire with 6A/16 A 230 V, combined socket near exhaust fan & controlling 16 A 230 V SP MCB near entrance/as indicated in drawing housed in 14 SWG CRCA box , 3 mm thick coloured FR sheet cover plate with necessary cut out fixed with chromium plated brass screws & cup washers with earthing stud etc . MCB shall be with 10 KA breaking capacity.

4

-

-

... More
Point wiring with 16 A DP MCB with 3 Nos of 2.5 sq.mm copper wire in 25 mm dia conduit in lift machine room . Supply to be taken from DB in lift machine room.(1 pt per shaft )

2

-

-

... More
In Flats :

-

-

-

... More
Light point with 2 Nos 1.5 sq.mm. wires and 1 Nos of 2.5 sqmm Earth wire , 230 V, 6A switch.

1092

-

-

... More
Socket outlet point with 2Nos of 1.5 sq.mm wires and 2.5 sq.mm Earth wire complete with 6 A 230 V 3pin socket , 6 A 230 V switch in one box (looped to lighting circuit).

520

-

-

... More
6 A /16 A combined socket outlets point with 3 nos of 2.5 sq.mm. wires, & 1 No. 16 A Switch.

312

-

-

... More
Point wiring for single phase exhaust fan with 2 Nos 1.5 sq mm wire & 1 Nos of 2.5 sqmm earth wire complete with 6 A, 230 V , 3 pin socket near exhaust fan & controlling 6 A , 230 V SP switch near entrance/as indicated in drawing.

52

-

-

... More
Ceiling fan points with 2 Nos 1.5 sq mm wire & 1 Nos of 2.5 sqmm earth wire complete with 6A, 230 V,SP switches without regulator.

364

-

-

... More
Supply Installation, testing & commissioning of Electric call bell points wiring with 2 Nos 1.5 sq mm wire & 1 Nos of 2.5 sqmm earth wire complete 6 A 230 V bell push and including supply of approved make electronic buzzer with polycorbonate body etc , in existing 25 to 38mm dia. HG ERW conduit concealed/ exposed in slab/wall, Scope also includes, clearing of conduit by pulling fish wire, rubber bushing etc. for pulling of wire as required in existing conduit,3 plate ceiling rose/3 core/twin flexible copper chords, connectors,connectors etc. as per specifications & drawings and as per instructions of Engineer-in-charge & as detailed below: Note:-Bell Push button with modular plates will be supplied by department. Note:-Following works also includes in agency scope:- (1) Point wiring means 3-wire system (Circuit) includes from DB to Bell push and bell push to electronic buzzer is to be included in point wiring works. (2) Connections shall be done with crimped type tinned copper lugs & washers (3) Wire marking(ferrule) used each end of point wiring circuits are included in agency scope.

52

-

-

... More
Supply Installation, testing & commissioning of Water heater point with 2 nos of 4-sq. mm wire along with 1Nos of 2.5 sq.mm earth wire from DB to Water heater point with 20 A DP MCB in existing readymade powder coted MS enclosure near Door at suitable position and 20A 3 way connector Block mounted in readymade powder coted MS enclosure near water Heater, in existing 25 to 38mm dia. HG ERW conduit concealed/ exposed in slab/wall, Scope also includes, clearing of conduit by pulling fish wire, rubber bushing etc. for pulling of wire as required in existing conduit,3 plate ceiling rose/3 core/twin flexible copper chords, connectors,connectors etc. as per specifications & drawings and as per instructions of Engineer-in-charge & as detailed below: Note:-Following works also includes in agency scope:- (1) Point wiring means 3-wire system (Circuit) includes from DB to DP MCB and MCB to 20A 3 way connector Block is to be included in point wiring works. (2) Connections shall be done with crimped type tinned copper lugs & washers (3) Wire marking(ferrule) used each end of point wiring circuits are included in agency scope.

156

-

-

... More
Supply Installation, testing & commissioning of AC point wiring with 2 nos of 4 sq.mm along with 1 Nos 2.5 sqmm of earth wire from DB to AC point is complete with 20 A 3 pin socket outlet with plug (Industrial Type) for split AC unit & 20A SP MCB in readymade powder coted MS enclosure in existing 25 to 38mm dia. HG ERW conduit concealed/ exposed in slab/wall, Scope also includes, stucessary cutouts, interconnections earthing stud, clearing of conduit by pulling fish wire, rubber bushing etc. for pulling of wire as required in existing conduit,3 plate ceiling rose/3 core/twin flexible copper chords, connectors,connectors etc. as per specifications & drawings and as per instructions of Engineer-in-charge & as detailed below: Note:-Following works also includes in agency scope:- (1) Point wiring means 3-wire system (Circuit) includes from DB to AC point is to be included in point wiring works. (2) Connections shall be done with crimped type tinned copper lugs & washers. (3) Wire marking(ferrule) used each end of point wiring circuits are included in agency scope.

156

-

-

... More
Point wiring in the existing Concealed/Surface HGERW Conduit in Lift shaft:- Supply Installation, testing & commissioning of Point wiring of 3-wire system (Circuit) in lift shaft with PVC insulated FRLS multistranded copper conductor wires, in existing 25 to 38mm dia. HG ERW conduit concealed/ exposed in slab/wall . Scope also includes, 9 Watt LED Bulkhead, clearing of conduit by pulling fish wire, rubber bushing etc. for pulling of wire as required in existing conduit, brass/bakelite (straight/angular) lamp holders, 3 plate ceiling rose/3 core/twin flexible copper chords, connectors, etc. as per specifications & drawings and as per instructions of Engineer-in-charge & as detailed below: Note:-Switch/socket with modular plates will be supplied by department. Note:-Following works also includes in agency scope:- (1) Point wiring means 3-wire system (Circuit) includes from DB to Switch Board and switch board to Light/ceiling fan/Exhaust fan/wall mounted fan /6A/16A/6+16 socket outlet is to be included in point wiring works. (2) Connections shall be done with crimped type tinned copper lugs & washers. (3) Wire marking(ferrule) used each end of point wiring circuits are included in agency scope.

-

-

-

... More
Primary light point with 3 nos of 2.5 sq.mm wire in lift shaft with 6A/ 16 A combined socket outlet and 16 A switch and 9 Watt LED Bulkhead light with a 6 A switch all in one box including earthing. Supply to be taken from lift machine room DP MCB

6

-

-

... More
Secondary light point with 3 Nos of 2.5 sq.mm wire in lift shaft with 6A/16 A combined socket outlet and 16 A switch and 9-Watt LED Bulkhead light with a 6 A switch all in one box including earthing but looped to above primary point.

34

-

-

... More
Replacement / Fixing of MS Modular back Box of crabtree make-(Athena model): Installation of MS moduler back Box as per site conditions. Note:- MS Modular back Box will be supplied by the Department. Following works also includes in agency scope: . (1) Removal of existing MS box from wall, cutting of existing MS conduits (if required) & take away of the dismantled MS box. Suitable rebate for take way of scrape material shall be considered in quoted rate. (2) Concealment of new modular box (concealed type) in the place of removed Ms modular Box by making suitable space as required for installation of new modular Box by breaking the brick wall. cutting the existing conduits if required, Filling the leftover gaps in wall after placing the switchboard with cement mortar, bricks etc. finishing by applying white cement & touch up painting of that area by roller/brush with suitable paint etc.

-

-

-

... More
2 module Modular Box

502

-

-

... More
3 module Modular Box

440

-

-

... More
4 module Modular Box

130

-

-

... More
6 module Modular Box

124

-

-

... More
8 module Modular Box

176

-

-

... More
Acrylic/polycarbonate Cover Plate for Fan Hook Box :Supply & Installation of 2mm thick round Acrylic/polycarbonate cover plate overlapping by 15 mm for fixing on existing fan hook box with screws as per instruction of Engineer-In-charge.

364

-

-

... More
TELEPHONE WIRING IN EXISTING CONDUIT: Supply Installation, testing & commissioning of Point wiring with 2 pair x 0.50 m dia, 230 V grade annealed copper conductor PVC insulated, overall sheathed twisted telephone wires as per DOT specifications in existing 25-38 mm dia. HGERW MS conduit The points wiring also includes installation of RJ -11 connecter, ferrule numbers on both side of the circuits all terminations with ferrule /lugs if required, labelling all as per drawings, standards, specifications & as per instructions of E-I-C. *Telephone socket will be supplied by department. Note:- Following works also includes in agency scope (1) Point wiring means 2 pair X 0.50 mm dia wire from nearest TTB/MDF to assigned point including end termination of both pairs at TTB end and one pair in RJ-11 at other end. Point wiring in lift machine rooms shall be done from 18th floor. (2) G.A drawings & fabrications drawing are to be got approved from E-I.C. (3) Lugs, ferruling for circuit identification shall be included in Contractor’s Scope.

-

-

-

... More
Point wiring in flats

104

-

-

... More
Same as above but in lift machine room.

3

-

-

... More
Supply, installation, testing & commissioning of following Krone connector telephone tag block, readymade box fabricated out of 18/20 SWG MS CRCA sheet with necessary gland plate concealed/surface mounted and grouted on the wall/fixed on the column with anchor fasterners, with adequate space facility to be provided in the TTB, with front operable hinged door, cam type locking arrangement, neoprene rubber/cork gasket for joints, ring type wire bunchin clamps at 4 corners, painting with seven tank metal treatment process & with 2 coats of red oxide primer & 2 coats of approved shade (no.631 of I.S.5) enamel paint, name plate etc. all as per standards, specification, drawing & instructions of E.I.C. Note:- Following works also includes in agency scope: (1) Point distribution diagram shall put in side the TTB with polythene protective cover shall be included in Contractor’s Scope. (2) All fabrication drawings shall be got approved. (3) Final coat of painting shall be done at site after installation if required is included in Contractor’s Scope. (4) Scope also includes supply and installation of 38/50/75 mm dia GI pipe bend to shape for cable entry in ground floor,as required. (5) The connectors shall be disconnection type is included in Contractor’s Scope.

-

-

-

... More
400 pair telephone terminal box set consisting of 1) Disconnection module 2 /10 -- 40 nos. 2) Back mounting frame - 2/11 -- 40 nos ( C.T.box with mounting bracket ) 3) Transparent dust cover -- 1nos. Complete with all accessories 4) Label Holder - 1 nos

1

-

-

... More
20 pair telephone terminal box set consisting of: 1) Disconnection module 2 /10 -- 2 nos. 2) Back mounting frame - 2/11 -- 2 no ( C.T. box with mounting bracket ) 3) Transparent dust cover -- 1 no. complete with all accessories 4) Label Holder - 1 no

18

-

-

... More
Supply, laying, testing and commissioning of 0.5 mm dia 20 pair telephone cable, annealed copper conductor, Polyethyline insulated and PVC sheathed and overall PVC sheathed armoured telephone cables generally confirming to ITD S/WS-11-B and IS 1554 Part I in existing hume pipe/clamped to wall/column etc. with suitable clamps/saddles and fixing bolts and testing and commissioning as required and including making terminal joints, complete as required all as per drawings, standards, specifications and instructions of E-I-C.

650

-

-

... More
End jointing of 0.5 mm dia 20 pair telephone cable with supply of all jointing materials like cable glands, gland earthing insulation tape, wire dressing clamps/button tapes, painted saddles etc. as per the drawings, standards, specifications and as per the instructions of the Engineer-in-charge

36

-

-

... More
Cover of TV MS BOX & shaft MS Box with cover:

-

-

-

... More
Supply & Installation of cover plate of 3mm thick whight colour Acrylic sheet with screws for covring Existing TV Point MS Box (2M) in Flats. The Scope also includes clearing of conduit by pulling fish wire in existing 25-38mm dia HGERW MS conduit from Flats to Telephone shaft as per instructions of E-I-C.

104

-

-

... More
Supply & Installation of Concealed 8 Module MS Box with cover plate of 2 mm thick with screws & on box & cover 2coat red-oxide & 2 coat enamel paint shall be done at Telephone shaft for Inter cannection of coming existing 25-38mm dia HGERW MS conduit from Flats TV MS Box as per instructions of E-I-C.

19

-

-

... More
Fire Alarm System: (ITC): Installation, testing & commissionnig of addressable type fire alarm system as per Standards, drawing, specifications and as directed by E-I-C and consisting of the following: Note :- (1) Fire Alarm System single loop Panel & it's components like MCP, SD & Hooter (Make: Honeywell Esser) will be supplied by Department. (2) The system shall be got approved by municipal fire authority before start of work and after completion. 3) The scope includes liasoning with CFO, Mumbai Fire Brigade office & preparation of documents for obtaining Fire NOC.

-

-

-

... More
Installation, testing & commissionnig One loop addressable main fire control panel of original equipment manufacturer including housing, suitable for wall mounting complete with visual indicators (LCD) with distinct alarm for fire & fault , mains ON indication , test and reset provision,adequate capacity of battery charger as per IS requirement, maintenance free (VRLA) battery of 24 volts of appropriate AH capacity as per IS ,terminal block , wire way box, if required, painting , front openable lockable cover with front glass etc . The panel shall be capable of connection of minimum 127 addressable devices. Note:- (1) The evacuation tone shall be continous (2) If required, necessary M.S battery box with louvers and locking arrangement shall be provided. (3) Maintenance free (VRLA) battery of 24 volts of appropriate AH capacity as per IS shall be supplied & install in the FA Panel by contractor.

1

-

-

... More
Installation, testing & commissionnig Manually operated addressable break glass/pull station (square type/round type suitable for wall mounting surface/concealed) readymade by original equipment manufacturer having painted/engraved/embossed as “IN CASE OF FIRE BREAK GLASS” on it, small hammer fixed with chain, normally on contacts (silver tipped), painting and other accessories as required.

20

-

-

... More
Installation, testing & commissionnig Addressable Smoke detector unit with mounting base consisting of multi sensor detection system technology sensor , indicator (LED) for quick identification of fire location etc.The unit shall be suitable for mounting on ceiling/false ceiling with necessary materials as required.

2

-

-

... More
Installation, testing & commissionnig Addressable Hooter of original equipment manufacturer complete with , M.S mounting brackets, if required, and suitable for giving alert/evacuation alaram.

20

-

-

... More
Supply, installation,testing & commissioning of Transponder / Control Relay Module for integration with PA system / emergency voice evacuation system with surface mounting housing box all as per instruction of EIC.

1

-

-

... More
Supply,Installation, testing & commissionnig of Point Wiring for smoke detector, manual break glass station, hooter, response indicator , fault isolator with 2 core, 1.5 sq mm, copper coductor, shielded cable PVC insulated, flame retardant, test according to IS 694, ISI marked, multistranded, in existing 25 - 38mm dia Heavy Duty M.S. ERW conduit, concealed in slab/wall MS boxes fabricated out of 16 SWG thick CRCA sheet/junction boxes, looping connector block, termination on both ends with crimped tinned copper cable sockets, ferrule numbers, ferrule lugs, label specifications and as per the instructions of Engineer-in-charge.

400

-

-

... More
EMERGENCY VOICE EVACUATION SYSTEM(PA System): Supply, installation, testing & commissioning of public Address system as per relevant standards,as directed by E-I-C and consisting of the following: Note: Following works also includes in agency scope (1) The work shall be carried out by licensed agency complying Maharashtra Fire prevention & Life safety measures Act 2006 with latest amendments. (2) The scope includes liasoning with CFO, Mumbai Fire Brigade office & preparation of documents for obtaining Fire NOC. (3) Scope includes submission of factory test report of controller,amplifire, speakers call station etc. (4)Scope includes interconnection of various PAS components in 19" cabinet. (5)Make of all the components of PAS shall be same. (6) The system shall be suitable for networking using open technologies.

-

-

-

... More
Supply,installation,testing & commissioning of 8 zone digital System Controller complete in 19'' Rack mountable Dual tone, integration with existing Fire alarm system,control for Speech & Music, tone generator & Speech Processor with relays for activating tone & pre-recorded fire alarm messages etc Note: Scope also includes interconnection of existing FA panel( adjacent to proposed PA console ) with PA controller including testing & commissioning of interface of integrated FA-PA system

1

-

-

... More
PA Rack: Supply, installation, testing & commissioning of double section wall mounted pivoting type 19" racks of the 15U height, 600 mm depth rack having safety glass door & with standard accessories, including power supply panel, fans, cable manager, full cable entry plate with brush at top & bottom etc. complete as required & as per instructions of EIC. The scope includes installation / mounting of 19" racks with angle iron frame work etc. without extra cost.

1

-

-

... More
Speakers: Supply ,installation,testing & commissioning of 6W Wall mounted speakers with wall mounted braket & line matching transformers and selectable tap setting etc as specified in the tender specifications and as per instructions of EIC.

31

-

-

... More
Digital Power Amplifier : Supply, installation,testing & commissioning of 19''rack mounted class-D 2X500 W Power amplifier with on board DSP power for local signal processing,Switched mode power supply, Local audio inputs, Mains and battery operation and supervision,complete with following types as specified in the tender specifications and as per instructions of EIC.

1

-

-

... More
Call Station : Basic Call Station with Power 'ON' indication, status/fault indications, priority level of destination is higher than that of the pending announcement indication, Supervision of microphone capsule and with built in On board DSP power for local audio processing. The call station basic can make manual or prerecorded announcements to any pre-assigned zones. The call station shall be provided with 18" gooseneck type microphone. The call station shall be provided with built in numerical keypad. The call station shall be fully supervised and must supports failsafe operation. Even if the network controller fails, the call station shall be able to put through emergency calls.

1

-

-

... More
PA system cabling: Supply, installation, testing & commissioning of 2 core twin twisted 48/0.2 ATC, multi stranded, overall PVC insulated and armoured cable (Blue colour) on surface/ above false ceiling including cost of GI spacers, saddles etc. and including the cost of termination’s as required, complete as per instructions of E-I-C. The cost of mounting base boxes,required wall crossing holes & the cost of providing cable glands etc shall be included in the scope of work.

600

-

-

... More
UPS: Supply, installation, testing & commissioning of 2 kVA double conversion (online) rack mountable UPS with single phase input and single phase output configuration with min. 10 minutes battery backup at 100% load using inbuilt sealed maintenance free batteries, flexible chord with plug in existing network rack as per instructions of EIC.

1

-

-

... More
M.V.CABLES: Supply, installation, testing & commissioning of 1.1KV grade XLPE insulated, inner sheath PVC extruded, extruded outer sheath FRLS grade, anti rodent, anti termite PVC, GI strip/wire armoured, stranded/ solid aluminum conductor power cable confirming to IS :7098 part I with upto date amendments as indicated below, fixed on wall/column/slab or in existing hume pipe/ trench/shaft/pit on 5mm thick M.S flat/GI spacer/angle/support fixed with coach screws/ grouted in wall/anchor fasteners, 2mm thick G.I. fabricated saddle, all fixing accessories, etc. complete including painting of M.S spacers/angles and saddles. specifications, drawings & as per instructions of the Engineer-in-charge & of the following sizes:

-

-

-

... More
3.5 C x240 sq.mm stranded aluminum conductor G.I strip armoured cable on wall/column/in shaft/in hume pipe etc.

200

-

-

... More
3.5 C x185 sq.mm stranded aluminum conductor G.I strip armoured cable on wall/column/in shaft/in hume pipe etc.

50

-

-

... More
4 C x25 sq.mm stranded aluminum conductor G.I strip armoured cable on wall/column/in shaft/in hume pipe etc.

500

-

-

... More
4 C x 6 sq.mm copper conductor G.I wire armoured cable on wall/parapet wall/column/in shaft/in hume pipe

200

-

-

... More
End jointing : End jointing of cable by crimping with supply of all jointing materials like solderless tinned copper cable socket, cable glands, gland earthing, insulation tape, flux, duplicate interconnection between gland earthing strip and to the nearest earthing bus terminals as per the drawings, standards, specifications and as per instructions of E-I-C.

-

-

-

... More
3.5 C x240 sq.mm PVCA Aluminum Cable

4

-

-

... More
3.5 C x185 sq.mm PVCA Aluminum Cable

4

-

-

... More
4 C x25 sq.mm PVCA Aluminum Cable

42

-

-

... More
4 C x 6 sq.mm Copper Cable

4

-

-

... More
Celing Fan: Supply, installation, testing & comissioning BLDC ceiling fan 1200.mm sweep with GI down rod of varying lenghts from min 260 mm to 1000 mm with compatible regulator, double ball bearing, canopies, shackles, blades with safety cable suspension (Secondary support safety cable) white colour with all accessories including continous earthing and final connection with 24/0.2 mm dia copper conductor 2/3 core twisted PVC lexible wire etc as per location & instructions of E-I-C Note: BLDC Fan should be as per technical specifications & testing conforming to IS 374/79 with latest amendments all as per specifications & instructions of E-I-C.

364

-

-

... More
Exhaust Fan: Supply, installation, testing & commissioning of 305 mm dia 900 rpm heavy duty, single phase 230 V, complete with blades, motor exhaust fans. Scope includes supply of 3C copper 2.5sq.mm. flexible chord of suitable length with 6A /16 A ,3 pin plug top, aluminium louvers shutters, rag bolt/Anchor fasterner, if required, 4 corners covered with 2 mm thick MS sheet to form suitable circular opening with necessary fixing arrangement with 40x40x3 mm angle iron frame, painting as per specification, drawing as directed by E-I-C.

4

-

-

... More
Mini instantaneous electric water heater:- Supply, installation, testing & commissioning of mini instantaneous electric water heater relevant ISI marked 3 KW, 1 litre capacity stainless steel outer container, tinned copper inner container with safety devices etc working on 230/230 V single phase supply including M.S supports fabricated out of 25 mm x 5 mm thick M.S flat with 2 coat of red oxide and 2 coats of enamel paint fixed on wall with 3 nos of no.10 nettle fold wood screws in wall with nylon/phil plug and all mounting accessories including connection with suitable lugs. The scope of work includes supply with copper cable between geyser connector box and suitable C.P brass pipe with nut bolts, coupling to the inlet and outlet of the water heater and pipe line and all as per specifications,standards, drawings & instructions of E-I-C.

15

-

-

... More
Installation, testing & commissioning of mini instantaneous electric water heater relevant ISI marked 3 KW, 1 litre capacity stainless steel outer container, tinned copper inner container with safety devices etc working on 230/230 V single phase supply including M.S supports fabricated out of 25 mm x 5 mm thick M.S flat with 2 coat of red oxide and 2 coats of enamel paint fixed on wall with 3 nos of no.10 nettle fold wood screws in wall with nylon/phil plug and all mounting accessories including connection with suitable lugs. The scope of work includes supply with copper cable between geyser connector box and suitable C.P brass pipe with nut bolts, coupling to the inlet and outlet of the water heater and pipe line and all as per specifications,standards, drawings & instructions of E-I-C. Electric water heater will be supplied by Department. Note:- (1) The necessary water heater fixing accessaries shall be included in Contractor’s Scope.

156

-

-

... More
Luminaries :

-

-

-

... More
Supply, installation, testing & commissioning LED surface downlight luminaire having 1000 lumen nominal output similar to M/s. Wipro Cat. No. W LD 80-101- XXX-60-SM-12 W LED panel 6000K or equivalent approved.

20

-

-

... More
Supply, installation, testing & commissioning Surface mounted Bulkhead luminarie similar to M/s. Philips Cat No. WT202W LED 6S CW PSU S2 PC or equivalent approved.

3

-

-

... More
Supply, installation, testing & commissioning Surface mounted LED luminarie similar to M/S.Wipro makes 'Green Perform' Cat No. WLE 10-491-XXX-57-XX 39W XLINE or equivalent approved.

1

-

-

... More
Supply, installation, testing & commissioning Surface/Recess mounted luminaires similar to M/s Wipro make cat no. WLR 02 -781-XX-57-G2 70 W LED STREET or equivalent approved.

1

-

-

... More
Installation, testing & commissioning LED surface downlight luminaire having 1000 lumen nominal output similar to M/s. Wipro Cat. No. W LD 80-101- XXX-60-SM-12 W LED panel 6000K or equivalent approved. Note:- (1)Light fixture will be supplied by Department. (2)The necessary installation accessaries shall be included in Contractor’s Scope.

203

-

-

... More
Installation, testing & commissioning Supply, installation, testing & commissioning Surface mounted LED fixture similar to M/S.Wipro makes 'Green Perform' Cat No. WLE 10-491-XXX-57-XX 39W XLINE or equivalent approved. Note:- (1)Light fixture will be supplied by Department. (2)The necessary installation accessaries shall be included in Contractor’s Scope.

6

-

-

... More
Installation, testing & commissioning Surface/Recess mounted luminaires similar to M/s Wipro make cat no. WLR 02 -781-XX-57-G2 70 W LED STREET or equivalent approved. Note:- (1)Light fixture will be supplied by Department. (2)The necessary installation accessaries shall be included in Contractor’s Scope.

6

-

-

... More
LIGHTNING PROTECTION SYSTEM

-

-

-

... More
Supply, installation, testing & commissioning of test link box consisting of 37 X 6 mm, heavily hot dipped GI test link, 25 X 8mm GI nut bolts & washers, suitable enclosure made of 2mm thick MS CRCA sheet with GI fixing screws/anchor fasteners etc., complete all as per STD drawing CSG/EM/STD -26 , specifications and as per the instructions of Engineer-in-charge.

9

-

-

... More
Supply, installation, testing & commissioning of 25 x 6 mm heavily hot dipped GI earth strip for roof conductors fixed on roof/wall/slab/ column with 5mm thick GI spacers fixed with no. 10 GI wood screws & 2 mm thick GI saddles with GI machine screws, interconnection of earth strip with welded joints and GI nut bolts & washer painting with two coats of metallic paint, etc. instructions of Engineer-in-charge.

300

-

-

... More
Supply, installation, testing & commissioning of 25 x 6 mm heavily hot dipped GI earth strip for down conductors fixed on roof/wall/slab/ column with 5mm.thick GI spacers fixed with no. 10 GI wood screws & 2 mm thick GI saddles with GI machine screws, interconnection of earth strip with welded joints and GI nut bolts & washer painting with two coats of metallic paint, etc. instructions of Engineer-in-charge.

750

-

-

... More
Supply, installation, testing & commissioning 37 X 6mm heavily hot dipped GI earth strip for ground conductors fixed with no.10 GI wood screws & 1-2 mm thick GI saddles with G.I machine screws or in ground at 750mm below including excavation in all types of soil/rock with temporary reinstatement & back filling of trench,interconnection of earth strip with welded joints and GI nut bolts & washers, painting with two coats of metallic Aluminium paint for above ground portion & painting with two coats of black bituminous compound for earth strip in ground etc. all as per drawing, specifications and as per the instructions of the Engineer-in-charge.

300

-

-

... More
MAINTENANCE FREE EARTHING SYSTEM:- Supply, installation,testing & commissioning of maintenance free earthing system & associated works, etc.complete as per specifications & instructions of E-I-C. NOTE: 1) Measurement of Earth resistance must be carried out as per instructions of EIC. 2) All type of excavation shall be measured under this item.

-

-

-

... More
Providing and making earth station comprising of 17 mm dia 3m long earthing electrode of high tensile low carbon steel rod molecularly bonded 250 micron copper coating on the outer surface, UL listed, filling bore with suitable earth enhancement compound as per IEC 62561-7 & manufacturer's standard, surrounding the earth electrode complete with all required materials & instructions of EIC. Note: The agency scope includes: 1) Installation of earth rods including making pit/ drilling rock as per manufacturer's recommendations & design: 2) Exothermic welding of joints between earth electrode & GI / tinned Cu strip and between GI / tinned Cu strips,used for interconnection of earth electrodes: 3) Each earth electrode shall be provided with poly plastic inspection chamber with cover as per OEM standard.

15

-

-

... More
Supply, installation of tinned copper earth wire/strip fixed to wall/side of trench/slab/ column/beam with 5mm thick GI spacers and 2mm thick GI saddles or in ground at 750 mm below including excavation in ground with protective baked bricks, excavation in ground refilling and removal of excess earth within a radius of 500 m, temporary reinstatement and back filling of trench, interconnection of earthstrip/wire with brass nut bolts and washers and solder/brazing jointing, painting with two coats of black bituminous compound for earth wire/stripin ground and green enamel paint for earth wire/strip on surface etc.

-

-

-

... More
8 SWG tinned copper wire

800

-

-

... More
25 x 6 mm tinned copper strip

500

-

-

... More
Installation of HMS PVC conduit concealed / surface with all fixing accessories of following sizes :-of: Note-HMS PVC conduit & Accessories will be supplied will be supplied by Department.

-

-

-

... More
25 mm dia.

2000

-

-

... More
32 mm dia.

500

-

-

... More
Installation of ERW MS conduit concealed / surface with all fixing accessories of following sizes :- of: Note-ERW MS conduit with Accessories will be supplied by Department.

-

-

-

... More
25 mm dia.

1100

-

-

... More
32 mm dia.

280

-

-

... More
PVC trunking System : Supply & installation of following sizes of ISI marked white / Ivory u-PVC mini trunking &white uPVC maxi trunking with its all accessories on surface of slab/wall/column fixed with nylon plug, with counter sunk tinned brass wood screws etc. complete with all accessories like junction boxes, coupler, elbow , Tees, PVC clamps, etc. as required at site & as per instructions of EIC.

-

-

-

... More
25 mm x 16 mm

500

-

-

... More
38 mm x 38 mm

200

-

-

... More
75mm x50mm

500

-

-

... More
CABLE TRAYS AND CABLE MANAGEMENT SYSTEM : Supply & Installation of following sizes of ladder type sheet metal hot dip galvanized cable trays with C profile side channel & C profile rung of spacing 300 mm centre to centre complete with horizontal and vertical bends, reducers, tees, cross members and other accessories as required and duly suspended from the ceiling / wall with supporting arrangement hot dip galvanized MS angle / MS flat / MS channel / hangers / threaded rods etc. as required as per specifications and instructions of E.I.C.

-

-

-

... More
300 mm (width) x 100 mm (height of side channel)x1.5 mm thickness.

60

-

-

... More
Supply, fabrication and installation of MS channel/angle/flat/Ms sheet/plate etc including painting with 2 coats of primer and 2 coats of epoxy paint of approved shade all as per instructions of E-I-C

1000

-

-

... More
Powered Signage: Supply, installation, testing & commissioning of LED power signage complete with accessories on surface of slab/beam by 2 nos (minimum) of 6 mm anchor fasteners or on wall with 2 nos of wood screws, nylon plug etc,suitable supporting frame fixed with rag bolts grouted on the wall/anchor fastener on the beam/on the column & other fixing accessories etc provision & connection with 1.5 sq.mm multistranded copper conductor FRLS PVC wires etc., all as per drawing, specifications & as per the instruction of E.I.C. Notes: (1) Sample luminaire/fittings shall be got approved from Dept. with complete technical data. (2) All luminairess shall be with drivers. (3) Cost of mounting accessories shall be included in luminaires cost. (4) The lumen output indicated is minimum system output of luminaire. (5) No negative tolerance is allowed on minimum system performance parameters indicated in the SOQ and specifications. (6) The CCT of the luminaire shall be decided at time of work execution

-

-

-

... More
LED egress surface/recess, maintained type (single side viewing power signage) in corridor near staircase with 1 hour backup similar to PEL LED E/M of M/s Prolite with all required hardware, egress symbols etc as per instructions of EIC.

30

-

-

... More
LED egress surface/recess, maintained type (Double side viewing power signage) in corridor near staircase with 1 hour backup similar to PEL LED E/M of M/s Prolite with all required hardware, egress symbols etc as per instructions of EIC.

20

-

-

... More
Non Powered Signage:-Supply & fixing of rigid self adhesive photoluminescent AUTOGLO sheet for indoor of different sizes & signage’s as per instruction of EIC.

100

-

-

... More
Supply & installation of pre mixed & ready to use M/s. HILTI make firestop foam FS-One Max in 300ml bottle for sealing openings in electrical shafts, Telephone shaft, raceways & cutouts, hump pipes & where ever required & as per instruction of EIC. Note: The work of foam application should be done through authorised applicator.

40

-

-

... More
Supply & installation of pre mixed & ready to use M/s. HILTI make firestop mortar CP 636 for sealing openings in electrical shafts, Telephone shaft, raceways & cutouts, hump pipes & where ever required & as per instruction of EIC.

600

-

-

... More
Supply and fixing of danger plates made of mild steel 200x150mm atleast 2 mm thick & vitreous enameled white on both sides and with inscriptions "Medium Voltage" in single red colour on front side as required.

5

-

-

... More
Supply and fixing of carbon di-oxide (CO2) type fire extinguishers conforming to IS 15683 and cylinders fully charged of 4.5kg capacity.

4

-

-

... More
Supply and fixing in position of 'A' class ELASTOMER' 'insulating Earth mat for protection to operators for working voltages upto 3.3 KV as per IS 15652 - 2006 of size 1000 mm (W) as per instructions of EIC.

80

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.