Cooperation Marketing And Textiles Department Tender

Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.

Cooperation Marketing And Textiles Department Tender

Works
Civil And Construction
Eprocure
Opening Date30 Mar 2022
Closing Date4 May 2022
Tender AmountRefer Documents 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Dressing of side shoulder / Scrapping the road side shoulder by Mechanical means ( By JCB /DOUZER) including excavation of raised side shoulders upto 15cm depth including remooving /cutting bushes,grass and dressing shoulder to desired camber and disposing of excavated stuff up to road boundary etc complete. ( S.S.R. 2021 - 2022 , Page no. 97 Item no. 8.23, Additional Additional Specification :- - as directed by Engineer In Charge.)

775

-

-

... More
Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5 m.) (S.S.R. 2021 - 2022, Page no.197 Item no. 21.02, Additional Specification- Bd.A.1 Page No. 259)

197.94

-

-

... More
Excavation for foundation in earth, soils of all types, sand, gravel and soft murum, including removing the excavated material upto a distance of 50 m. beyond the building area and stacking or spreading as directed, preparing the bed for the foundation and necessary back filling, ramming, watering, including shoring and strutting as necessary complete. (Lift from 1.5 m to 3.00 mt.) (S.S.R. 2021 - 2022, Page no.197 Item no. 21.04, Additional Specification- Bd.A.1 Page No. 259)

8.73

-

-

... More
Excavation for foundation in hard murum including removing the excavated material upto distance of 50 metres beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.50 m) By Mechanical Means. (S.S.R. 2021 - 2022,Page no.197 Item no. 21.06,Additional Specification - Bd.A.2 Page No. 259)

151.96

-

-

... More
Excavation for foundation in Hard murum and boulders including removing the excavated material upto a distance of 50 metres, beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5 m.) (S.S.R. 2021 - 2022,Page no.197 Item no. 21.10,Additional Specification- Bd.A.3 Page No. 259)

141.38

-

-

... More
Excavation for foundation in Hard murum and boulders including removing the excavated material upto a distance of 50 metres, beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift 1.5 to 3.00 mt) (S.S.R. 2021 - 2022,Page no.197 Item no. 21.12,Additional Specification- Bd.A.3 Page No. 259)

9.86

-

-

... More
Excavation for foundation in Soft rock and old cement or lime masonry foundations including removing the excavated material upto a distance of 50 metres beyond the building area and stacking as directed, including dewatering, preparing the bed for the foundation and necessary back filling with available earth /murum, ramming, watering including shoring and strutting etc. complete (lift upto 1.5m) By Mechanical Means Spec.No. : Bd.A.4, Page No. 259.. (S. S. R. I. No. 21.14 & P. No. 188)

6.76

-

-

... More
Providing preconstructional antitermite treatment (S.S.R. 2021 - 2022,Page no. 40 Item no 2-9-4 as per I.S. 6313 (Part-II) by treating the bottom surface and sides of excavation at the rate of 5 litres of emulsion concentrate of 1.0 percent of chlorophyrifos per square meter of surface area covering 10 years guarantee on bond paper. (S.S.R. 2021 - 2022,Page no.199 Item no. 21.22,Additional Specification- As directed by Engineer in charge.)

421.01

-

-

... More
Providing preconstructional antitermite treatment (S.S.R. 2021 - 2022,Page no. 40 Item no 2-9-4 as per I.S. 6313 (Part-II) by treating the top surface of plinth filling at the rate of 5 litres of emulsion concentrate at 1.0 percent of clorophyrifos per square metre of surface area covering ten years guarantee on bond paper . (S.S.R. 2021 - 2022,Page no.199 Item no. 21.24,Additional Specification- As directed by Engineer in charge.)

767.57

-

-

... More
Filling in plinthe and floors with approved excavated material in 15cm to 20cm including watering and compacting etc. complete. (S.S.R. 2021 - 2022,Page no.201 Item no. 21.36,Additional Specification- Bd.A.10 Page No.262)

351.92

-

-

... More
Filling in plinth and floors with contractors material/brought from outside and approved by Engineer incharge in layers of 15 cm to 20 cm including watering and compaction etc complete. (S.S.R. 2021 - 2022,Page no.201 Item no. 21.37,Additional Specification- Bd.A.11 Page No.263)

2363.06

-

-

... More
Conveying materials obtained from road cutting including all lifts, laying in layers of 20cm to 30cm. breaking clods, dressing to the required lines, curves, grades and section, watering and compacting to not less than 97% of standard Proctor density for a lead of over 50 m. to 300 m. inclusive from the site of excavation to the site of deposition as directed. (S.S.R. 2021 - 2022,Page no.28 Item no. 2.25,Additional Specification- MORTH 305)

295.34

-

-

... More
Disposing of dismantling materials of R.C.C. stone/ brick masonry / derbies, excavated material etc from work site beyond the 5 km Spec. No.:As directed by Engineer in charge etc. complete. ( D.S.R, Page No. 125, Sr. No. 486 )

171.37

-

-

... More
Providing soling using 80 mm size trap metal in 15 cm. layer including filling voids with Crushed sand/grit, ramming, watering etc. complete. (S.S.R. 2021 - 2022, Page no.201 Item no. 21.40,Additional Specification- As directed by Engineer in charge.)

185.47

-

-

... More
Providing and laying Cast in situ/Ready Mix cement concrete in M-10 of trap / granite / quartzite / gneiss metal for foundation and bedding including bailing out water, Steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing if required and curing complete, with fully automatic micro processor based PLC with SCADA enabled reversibleDrum Type mixer/concrete Batch mix plant ( Pan mixer ) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) ) Spec. No. Bd. E. 1 Page No287 (S. S. R. I. No. 24.01 & P. No. 217)

28.88

-

-

... More
Providing and laying Cast in situ/Ready Mix cement concrete in M-15 of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including bailing out water, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing if required and curing complete, with fully automaticn micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc complete. With natural sand/V.S.I. quality Artificial Sand .(S.S.R. 2021 - 2022,Page no.227 Item no. 24.08,Additional Specification Bd.E.4 Page No.289 and B-7, pageno.38.)

128.4

-

-

... More
Providing and laying in situ/Ready Mix cement concrete M-20 of trap / granite /quartzite/ gneiss metal for R.C.C. work in foundations like raft, strip foundations, grillage and footings of R.C.C. columns and steel stanchions etc. including bailing out water, formwork, laying/pumping cover blocks, compaction and curing roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based PLC withnSCADA enabled reversible Drum Type mixer/ concrete Batchn mix plant (Pan mixer) etc. complete. With natural sand/V.S.I.quality Artificial Sand. (S.S.R. 2021 - 2022,Page no.230 Item no. 25.11, Additional Specification- Bd.F.3 Page No. 298 and B.7, PageNo.38)

24.38

-

-

... More
Providing and laying Cast in situ/Ready Mix cement concrete M- 20 of trap / granite /quartzite/ gneiss metal for R.C.C. columns (S.S.R. 2021 - 2022,Page no. 40 Item no 2-9-4 as per detailed designs and drawing or as directed including centering, formwork, cover blocks, laying/pumping,compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With natural sand/V.S.I. quality Artificial Sand . (S.S.R. 2021 - 2022, Page no.232 Item no. 25.31,Additional Specification-Bd.F.5 Page No.300 and B.7,Page.No. 38)

47.98

-

-

... More
Providing and laying Cast in situ/Ready Mix cement concrete M- 20 of trap / granite /quartzite/ gneiss metal for R.C.C. beams and lintels (S.S.R. 2021 - 2022,Page no. 40 Item no 2-9-4 as per detailed designs and drawings or as directed including centering, formwork, cover blocks, laying/pumping,compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With natural sand/V.S.I. quality Artificial Sand. (S.S.R. 2021 - 2022,Page no.234 Item no. 25.50,Additional Specification- Bd.F.6 Page No. 300 and B.7, Page No.38)

91.3

-

-

... More
Providing and laying Cast in situ/Ready Mix cement concrete M-20 of trap/ granite/ quartzite/ gneiss metal for R.C.C. chajja / Canopy (S.S.R. 2021 - 2022,Page no. 40 Item no 2-9-4 as per detailed design and drawings including steel centering, formwork, cover blocks compacting , curing , finishing and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc). (S.S.R. 2021 - 2022,Page no.239 Item no. 26.05,Additional Specification- Bd.F.9 Page No. 303 and B.7, Page No.38)

4.19

-

-

... More
Providing and laying Cast in situ/Ready Mix cement concrete in M-20 of trap/ granite/ quartzite/ gneiss metal for R.C.C. pardi of required thickness including steel centering, formwork, cover blocks, laying/pumping, ompacting , curing , finishing and rougheningthem if special finish is to be provided and curing complete.(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) . (S.S.R. 2021 - 2022,Page no.240 Item no. 26.17, Additional Specification- Bd.F.11 Page No.304 and B.7, Page No. 38)

2.25

-

-

... More
Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap / granite /quartzite/ gneiss metal for R.C.C. work in foundations like raft, strip foundations, grillage and footings of R.C.C. columns and steel stanchions etc. including bailing out water, Steel centering, formwork ,cover blocks, laying/pumping, compaction and curing roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc). Spec. No. Bd. F.3 Page No. 298 and B.7, Page No. 38 (S. S. R. I. No. 25.13 & P. No. 222)

31.48

-

-

... More
Providing and casting in situ cement concrete of M25 of trap / granite /quartzite/ gneiss metal for R.C.C. columns as per detailed design and drawings or as directed, including steel centering, plywood/steel formwork, compaction, finishing uneven and honeycombed surface with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing etc. complete. Including use of plastisizer wherever necessary as directed by Engineer (Excluding reinforcement, including cover block). The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed)

0.8

-

-

... More
Providing and casting in situ cement concrete of M25 grade of trap / granite /quartzite /gneiss metal for R.C.C. beams and lintels as per detailed design and drawings or as directed,including steel centering, plywood/steel formwork steel props, compaction, finishing uneven and honeycombed surface with C.M.1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete. Including use of plastisizer wherever necessary as directed by Engineer-In-charge (Excluding reinforcement, including cover block). The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed)

4.5

-

-

... More
Providing and casting in situ cement concrete of M25 of trap / granite /quartzite /gneiss metal for R.C.C Chajja as per detailed design and drawings including steel centering, plywood /steel formwork, steel props, compaction, finishing uneven and honeycombed surface with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided with fan hook box of 2 mm thick M.S.Sheet rectangular size 180 mm x 100 mm with required depth, with holes or notches, as required, bottom and top lids of 1.6 mm thick M.S.Sheet

0.04

-

-

... More
Providing and laying Cast in situ/ReadyMix cement concrete in M-25 of trap/granite/quartzite/gneiss metal for R.C.C. pardi of required thickness including steel centering, formwork, cover blocks, laying/pumping, compacting and roughening them if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel). with fully automatic microprocessor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand/Crushed sand VSI Grade finely washed etc) Spec. No. Bd.F.11 Page No. 304 and B.7, Page No. 38 (S. S. R. I. No. 26.19 & P. No. 240)

37.2

-

-

... More
Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap/ granite / quartzite/ gneiss metal for R.C.C. slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks, compaction, finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete.(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete.With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) Spec. No. Bd.F.8 Page No. 302 and B.7, Page No.38 (S. S. R. I. No. 25.72 & P. No. 227)

24.19

-

-

... More
Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations,slabs, beams columns, canopies, staircase, newels, chajjas,lintels pardis, copings, fins, arches etc. (S.S.R. 2021 - 2022,Page no. 40 Item no 2-9-4 as per detailed designs,drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete. (S.S.R. 2021 - 2022,Page no.245 Item no. 26.33,Additional Specification- Bd.F.17, Page No.306)

27.25

-

-

... More
Providing and fabricating structural steel work in rolled sections like joists, channels, angles, tees etc. (S.S.R. 2021 - 2022,Page no. 40 Item no 2-9-4 as per detailed design and drawings or as directed including cutting, fabricating, hoisting, erecting, fixing in position making riveted / bolted /welded connections without connecting plates, braces etc. and including one coat of anticorrosive paint and over it two coats of oil painting of approved quality and shade etc. complete. (S.S.R. 2021 - 2022, , Page no.223 Item no. 23.01,Additional Specification- Bd.C.2 Page No.275)

16.8

-

-

... More
Providing second class Burnt Brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in foundations and plinth of inner walls/ in plinth external walls including bailing out water manually , striking joints on unexposed faces, raking out joints on exposed faces and watering etc. Complete. (S.S.R. 2021 - 2022,Page no. 254 Item no. 27.01,Additional Specification- Bd.G. 1 Page No.313)

85.31

-

-

... More
Providing fly ash brick masonry with conventional / I.S. type fly ash bricks in C.M. 1:6 in foundation and plinth including bailing out water manually striking joints, racking out joints watering and scaffolding etc. complete.(S.S.R. 2021 - 2022,Page no.144 Item no. 27.12)

0.75

-

-

... More
Providing fly ash brick masonry with conventional / I.S. type fly ash bricks in C.M. 1:6 in superstructure including bailing out water manually striking joints, racking out joints watering and scaffolding etc. complete.(S.S.R. 2021 - 2022,Page no.144 Item no. 27.13)

9.67

-

-

... More
Providing second class Burnt Brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in superstructure including striking joints, raking out joints, watering and scaffolding etc. Complete. ( S.S.R. 2021 - 2022, Page no. 254 Item no. 39.24,Additional Specification- Bd.G.5 Page No.315)

183.31

-

-

... More
Providing and constructing Brick Masonry Inspection Chamber 60cm x 45cm x 90cm including 1:4:8 cement concrete foundation 1:2:4 cement concrete channels half round G.S.W. pipes, Brick Masonry, plastering from inside and with frame fixed in cement concrete with R.C.C. Cover medium duty 140 kg with frame etc complete. Spec. No. Bd.V.43 Page No.574. (S. S. R. I. No. 42.17 & Page No. 353 )

15

-

-

... More
Providing and fixing rolling shutter fabricated from steel laths of minimum thickness 0.9 mm with lock plate of 3.15 mm thickness reinforced with 35 x 35 x 5 mm angle section fitted with sliding bolts and handles for both sides, deep M.S. channel section of depth and thickness not less than 65 mm and 3.15 mm respectively with hold fast arrangements, M.S. Bracket plate 300 x 300 x 3.15 mm minimum size and shape with square bar, suspension shaft of minimum 32 mm diameter, hood cover of M.S. sheet not less than 0.9 mm thickness and of any size at top and safety devices including mechanical gear operation arrangement consisting of worm gear wheels and worms of high grade cast iron or mild steel and one coat of red lead primer etc complete. (I.S. 62481979) (Without mechanical gear. (S.S.R. 2021 - 2022,Page no. 318 Item no. 27.05,Additional Specification- BD-T-55 Page No.510)

27

-

-

... More
Providing and fixing chicken mesh of 22 gauge, with about 30 cm.width at the junction of R.C.C members and brick work, of approved quality including fixing mesh in position by necessary drilling in concrete /B.B.masonry and or tying by binding wire etc. complete. (S.S.R. 2021 - 2022,Page no. 270 Item no. 32.26,Additional Specification- As directed by Engineer in Charge)

393.41

-

-

... More
Providing and fixing mild steel grill work for windows, ventilators, etc. 15 kg/sqm as per drawing including fixtures necessary welding and painting with one coat of anticorrosive paint and two coats of oil painting complete.(S.S.R. 2021 - 2022,Page no. 192 Item no. 40.02)

0.56

-

-

... More
Providing internal cement plaster 12mm thick in single coat in cement mortar 1:4 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc complete. (S.S.R. 2021 - 2022,Page no. 153 Item no 32.04,Additional Specification- Bd. L.2 Page No.368)

1426.36

-

-

... More
Providing internal cement plaster 12 mm thick in a single coat in cement mortar 1:5 without neeru finish to concrete or brick surface in all positions including scaffolding and curing complete. Providing groove at joint of B.B. Masonry and concrete members complete (S.S.R. 2021 - 2022,Page no. 153 Item no 32.03,Additional Specification- Bd. L.2 Page No.368

73.51

-

-

... More
Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 mm thick in cement mortar 1:4 using waterproofing compound at 1 kg per cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 mm thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc.complete. (S.S.R. 2021 - 2022,Page no. 269 Item no 32.11,Additional Specification- Bd.L.7 Page No.369)

1391.25

-

-

... More
Providing fine cement finish 1.5 mm thick over green plaster surface including scaffolding curing etc. complete.Spec. As directed by Engineer in charge. (S. S. R. I. No. 32.21 & Page No. 269)

330

-

-

... More
Providing and fixing colour coated Zinc alume (R) AZ150 (min 150 gms/sq.mt .total one ach side) profiled sheets for roofing. The feed materialis manufacture doutof nominal 0.45mm Base Metal Thickness (BMT) (0.5mmTCT),Hi-strength steel with min. 550M Payield strength, meta llichot dipcoated with Aluminium-Zincalloy (55% aluminium 43.4% zinc 1.6% silicon) with COLORBOND (R) steel quality super durable polyester paint coa (within organic pigment).The paint shall have a total coating thickness of nominal 35 um, comprising of nominal 25 umexterior coaton top surface and nominal 10 um reverse coaton back surface .Profilesheet shall have nom.950-1050mm effective cover width and nominal 25-30mm deep ribs with subtle square fluting in the five pan at nominal 180-250 mm center-to-center.The end rib shall be designed foranti-capillary groove.and returnleg.Thefeedmaterialshouldhavecoilmanufacturersproductdetailsmarkedaregularinterval.Includingfastenerswithmin.fastenedwithmin.25umZinc-Tinalloycoated,Hexhead,self-drillingscrewetc.complete.(weightofprofile4.52kg/sqm)

710.43

-

-

... More
Providing and applying two coats of exterior acraylic emulsion paint confirming to orresponding I.S. of approved manufacture and of approved colour to the plastered surfaces including cleaning ,preparing the plaster surface, applying primer coat ,scaffolding if necessary , and watering the surface for two days etc complete. (S.S.R. 2021 - 2022,Page no. 288 Item no. 35.25,Additional Specification-As directed by Engineer in charge.)

1251.7

-

-

... More
Providing and applying washable oil-bound distemper of approved colour and shade to old and new surfaces in two coats including scaffolding, preparing the surfaces. (excluding the primer coat.) etc. complete. (S.S.R. 2021 - 2022,Page no. 291 Item no. 36.11,Additional Specification- Bd.P.5 Page No.413)

1089.93

-

-

... More
Providing and applying priming coat on concrete/ masonary/ Asbestos Cement plastered surfaces including scaffolding if necessary, preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter and sand papering as required etc. complete. (S.S.R. 2021 - 2022, page no. 288 Item no. 35.21,Additional Specification- As directed by Engineer in charge.)

1065.72

-

-

... More
Providing and applying two coats of synthetic enamel paint of approved colour to new /old structural steel work and wood work in buildings, including scaffolding if necessary, cleaning and preparing the surface (excluding primer coat) etc. complete. (S.S.R. 2021 - 2022,Page no. 286 Item no. 35.07,Additional Specification-Bd.O.5 Page No.405)

36

-

-

... More
Providing and fixing welded mesh of 11 gauge wires having mesh size 50 mm x 25 mm including M.S Angle frame of size 35 mm x 35 mm x5 mm in position with oil painting 3 coats etc. complete. ( S.S.R. 2021 - 2022,page no. 333 Item no. 39.79,Additional SpecificationAs directed by Engineer in charge.)

36

-

-

... More
Providing and applying two coats of exterior weather shield paint of approved manufacture and of approved colour to the plastered surfaces including cleaning ,preparing the plaster surface ,applying primer coat ,scaffolding if necessary, and watering the surface for two days etc complete.

54.7

-

-

... More
Providing and laying 125 micron Low Density Polyethylene (LDPE) sheet confirming to IS 3395 : 1997 below concrete pavement including all materials and labour complete. ( S.S.R. 2021 - 2022,Page no. 51 Item no. 5.19,Additional SpecificationRD)

670

-

-

... More
Providing and laying in situ cement concrete M-20 with tremix treatment for 100 mm thickness for flooring with groove cutting of 4 mm wide and 20 mm deep with necessary refilling with bitumen etc. complete. (S.S.R. 2021 - 2022,Page no. 227 Item no. 33.30 ,Additional SpecificationAs directed by Engineer in charge)

670

-

-

... More
Painting letters upto 20 cm height complete brushes, coir brushers, dusting, cleaning, including cost of paint etc. complete. ( S.S.R. 2021 - 2022,page no. 54 Item no. 6.05, Additional SpecificationMORTH 801)

240

-

-

... More
Providing and fixing P.V.C. Rain water pipes of 110mm outer diameter and having wall thickness of 2.2 to 2.7 mm confirming to I.S. 13592 1992 including proper rainwater receiving recess with P.V.C. plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25mm to 40mm from face of wall a fixing with clips of approved quality and number ,filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on C.C. or masonry blocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All the P.V.C. fittings and additional 2 piece socket clips shall be got approved from engineer in charge etc. complete. (S.S.R. 2021 - 2022,Page no. 363 Item no. 42.87, Additional SpecificationAs directed by Engineer Incharge.)

79

-

-

... More
Providing water proofing treatment (S.S.R. 2021 - 2022,Page no. 40 Item no 2-9-4 as per IS : 1346-1966 to generally inaccessible sloping Reinforced Cement Concrete Terrace slab with bitumen felts in all positions in five course, consisting of applying cold bitumen primer coat at the rate of 2.5 litre per 10 Sqm., hot bitumen layer at the rate of 14.50 kg per 10 Sqm. and over the same layer of bitumen felt of type III grade (I) (S.S.R. 2021 - 2022,Page no. 40 Item no 2-9-4 as per IS: 1332-1965 across the slope with 10 cm overlap commencing at lowest level and again applying hot bitumen course at the rate of 14.50 kg per 10 Sqm. and finally spreading over it grit at the rate of 14.50 kg per 10 Sqm. including all lifts, leads and scaffolding whenever necessary complete as directed with four years' guarantee on requisite stamp paper etc. complete. (S.S.R. 2021 - 2022,Page no. 259 Item no31.17,Additional SpecificationAs directed by Engineer Incharge.)

60.45

-

-

... More
p & F Turbo Ventilator page no. 516 , Item no. 42

10

-

-

... More
Providing and laying concrete pipes of I.S. NP. class of 150mm diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete.. Spec. No. Bd.V.41, Page No. 573 (S. S. R. I. No. 42.07 & Page No. 351)

30

-

-

... More
Providing and fixing P.V.C. Rain water pipes of 160mm outer diameter and having wall thickness of 2.2 to 2.7 mm confirming to I.S. 13592-1992 including proper rainwater receiving recess with P.V.C. plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25mm to 40mm from face of wall a fixing with clips of approved quality and number ,filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on C.C. or masonry blocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All the P.V.C. fittings and additional 2 piece socket clips shall be got approved from engineer in charge etc. complete. (S. S. R. I. No. 42.85 & Page No. 355)

80

-

-

... More
Providing and fixing P.V.C. Rain water pipes of 110mm outer diameter and having wall thickness of 2.2 to 2.7 mm confirming to I.S. 13592-1992 including proper rainwater receiving recess with P.V.C. plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25mm to 40mm from face of wall a fixing with clips of approved quality and number ,filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on C.C. or masonry blocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All the P.V.C. fittings and additional 2 piece socket clips shall be got approved from engineer in charge etc. complete. (S. S. R. I. No. 42.87 & Page No. 355)

70

-

-

... More
RWH - Recharge Pit Providing and constructing recharge pit of 2.0m deep and 1.0m dia of pre-cast RCC rings with 6.5"diax25m deep bore well at the floor of recharge pit including installation of combination of solid/perforated PVC casing pipe wrappe d around with netlon mesh including 300mm thick side filling around out side of RCC rings (annular space)with 40 mm size boulders including filling of recharge pit up to 0.5m depth with 25-75mm clean washed gravels from bottom up followed by 0.5m depth of 10-25mm of clean washed stones followed by 0.5m of washed river fineaggregate (naturalsand/crushedsandVSIgradefinelywashed etc.) including netlon mesh between each gravel /fineaggregate (naturalsand/crushedsandVSIgradefinelywashed etc.) medialayer including covering with RCC slab, manhole frame & cover, PVC rungs, PVC end-caps, fittings etc. including arrangement forinlet & outlet pipe excavation & back filling as shown in the drawing. The rate shall be inclusive of all labour, material, wastage,scaffolding,transportation,taxes, including all leads, lifts at all levels. All material should be of approved make. All works complete as per the drawing ,technical specification and direction of the Engineer in charge. (S. S. R. I. No. 48.47 & Page No. 405)

1

-

-

... More
Boring/drilling bore well of 300mm dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machinery required for the job, all complete as per direction of Engineer in charge, upto 90m depth below ground level. (S. S. R. I. No. 48.48 & Page No. )

63.25

-

-

... More
Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well-casing pipe of 150mm dia, conforming to IS:12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per the direction of Engineer in charge. (S. S. R. I. No. 48.49 & Page No. )

65

-

-

... More
Providing and laying concrete pipes of I.S. NP. class of 150mm diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete.. Spec. No. Bd.V.41, Page No. 573 (S. S. R. I. No. 42.07 & Page No. 351)

24.2

-

-

... More
RWH - Shallow Percolation Pit providing, constructing 2.0m deep shallow depth percolation pit comprising of 1.0m dia pre-cast RCC rings, 300mm thick side filling around outside of RCC rings (annular space) with 40mm size boulders including filling of percolation pit up to 0.5m depth (from bottom up) with 25-75mm clean washed gravels followed by 0.5m depth of 10-25mm of clean washed stones followed by 0.5m of washed river fine aggregate (natural sand/crushed sand VSI grade finely washed etc.) including netlon mesh between each gravel/fine aggregate (natural sand/crushed sand VSI grade finely washed etc.) media layer including covering with RCC slab, manhole frame & cover, PVC rungs etc. including arrangement for inlet & outlet pipe, excavation & backfilling as shown in the drawing. The rate shall be inclusive of all labour, material, wastage, scaffolding, transportation, taxes, including all leads, lifts at all levels. All material should be of approved make. All works complete as per the drawing, technical specification and direction of the Engineer in charge (S. S. R. I. No. 48.46 & Page No. 405)

3

-

-

... More
Garden soils :- Supplying one side fresh garden soil well sieved 90% to pass through IS sieve of 10 mm size free from stone rubbish like dried grass root & other such materials the soil should be fresh from quarry. The colour of the soil generally be red. The soil will be measured by measuring box. (Item include Royalty charges. Corporation types transporting loading Unloading etc. complete. Horticulture DSR 1/2

3.75

-

-

... More
Suplying & laying well quality of manuar required for small, large tress including mixing with soil , watering, transportation at site etc. completed Horticulture DSR 2/2

3.75

-

-

... More
Saplings of flowering/shadytrces Gulmohar, Raintree, Peltophorum etc (one year old) Horticulture DSR 8/3

25

-

-

... More
Saplings of Small & medium Ornamental flowering plants , Thuja,Cupresus plants ornamental Ficus, Mussanda etc. Horticulture DSR 9/3

60

-

-

... More
Rose Plant :- Excavating pit with size 0.3x0.3x0.3 meter removing & conveying unwanted stuff of a required distance as directed filling the fresh garden soil in minor in 3:1 proportion to a required height of 0.3 meter mixing the soil & minor levelling, watering on previous night. Planting 40 to 50 cm height healthy plant of required rose verity mainaining till well established by watering weeding, sturring,prunning, replacing the casualities etc. complete. Horticulture DSR 9/5

20

-

-

... More
Mogra Plant/Creepers/Climbers:- Excavating pit with size 0.3x0.3x0.3 meter removing & conveying unwanted stuff of a required distance as directed filling the pit upto excavated material upto a height 15 cm. & ramming height of 15 cm. with fresh garden soil in minor in 3:1 proportion mixing the soil & minor levelling, watering on previous night. Planting (one year old) healthy plant as per specification mainaining till well established by watering weeding, sturring,prunning, replacing the casualities etc. complete. Horticulture DSR 10/6

20

-

-

... More
Planting large flowering/shady trees:- Digging pit with size 0.9 x 0.9 x 0.9 meter. Removing & conveying unwanted stuff of a required distance as directed filling the pit upto excavated material upto a height 30 cm. & ramming height of 60 cm. with fresh garden soil in minor in 3:1 proportion mixing the soil & minor levelling, watering on previous night. Planting (one year old) healthy trees sapling as per specification mainaining till well established by watering weeding, sturring of soil replacing of casualities etc. complete. Horticulture DSR 12/6

20

-

-

... More
Planting small & medium size ornamental flowering plant:-Digging pit with size 0.6 x 0.6 x 0.6 meter. Removing & conveying unwanted stuff of a required distance as directed filling the pit with fresh garden soil & farm yard minor upto a height of 0.6 meter in 3:1 proportion mixing the soil & minor levelling, watering on previous night. Planting (one year or two year old) healthy plant sapling as per specification mainaining till well established by watering, weeding, sturring of soil replacing of casualities etc. complete. Horticulture DSR 11/6

20

-

-

... More
Preparing instant Lawn :- Excavating the ground to a required depth of 20 cm. removing & conveying unwanted stuff to a required distance as directed filling fresh garden soil in minor in 3:1 proportion to a height of 20 cm. mixing soil & minor throughly well levelling with required slope light watering on previous night, rolling on surface. Fixed readymade lawn truf rolls or slab of reqired verity as directed. ramming on it for proper fixing & mainaining till well establish by watering, weeding, clipping or moving etc. complete. Horticulture DSR 3/4

6.25

-

-

... More
Preparing Edging or border:- Excavating the ground to a required depth of 20 cm. removing & conveying unwanted stuff to a required distance as directed filling fresh garden soil in minor in 3:1 proportion to a required height of 20 cm. mixing , levelling , watering the same planting suitable verity of edging plants & rooted cutting at distance of 15 cm. between plants to plants and row to row watering & maintaining till well grown to te stage of prunning Horticulture DSR 4/4

15

-

-

... More
Preparing Shrubbery:- Excavating the ground to a required depth of 30 cm. removing & conveying unwanted stuff to a required distance as directed. Providing and filling fresh garden required distance as directed. Providing and filling fresh garden soil and manure in excavated area in 3:1 proportion to a required height of 30 cm. Mixing , levelling , watering on previous night. Planting well rooted shrubs 0.5 mtrs. apart as directed and maintaining till well established by watering, weeding, strring replacing of casualties etc. complete. Horticulture DSR 8/5

7.5

-

-

... More
Dustbin 240 Litre , WB-240 Dimensions : 725 x 580 x 1075 mm ( 107x72x58cm ) Heavy Duty Sunproof Waste Garbage Bins Wheeled Bins Easy to maintain & Use Envirnoment Friendly Long Lasting Capacity : 240 Litre (Non SSR)

5

-

-

... More
Providing waterproofing in W.C. and bath including brickbat coba in all position including providing and laying 12mm bedding in cement mortor 1:3 on vergin concrete slab with waterproofing compound @1kg/per bag of cement laying brickbat coba of required thickness in cm1:5with waterproofing compound1kg/bag of cement grouting and finishing the top layer with 20mm thick brick bedding in cm mortor 1:3 with waterproofing compound1kg/per bag of cement and testing the treated portion for 48 hours by pond test and covering ten years' guarantee on requisite stamppaper including curing etc. complete.

0.95

-

-

... More
Providing cement based waterproofing treatment to terraces(Indian waterproofing or alike)with brickbats laid in required slope to drain the water for any span after cleaning the base surface.Applying a coat of cement slurry admixed with approved waterproofing compound and laying the brickbats on bottom layer in C.M.1:5admixed with approved waterproofing compound filling upto half depth of brickbats,curing this layer for3days,applying cement slurry over this layer joint so fbrickbats with C.M.1:3 admixed with approvedwaterproofingcompoundandfinallytopfinishing with average 20mm.thick layers of same mortar added with jute fiber at 1Kg per bag including finishing the surface smooth with cement slurry admixed with approved waterproofing compound. Marking finished surface with false squares of 300mmx300mm. making the junctions at the parapet rounded and tapered top for required height,with drip mould at the junction of plaster and parapet and curing and covering 10 years Guarantee against leakproofness on Court fee stamppaper ofRs. 500/- including ponding test etc. complete.

8.83

-

-

... More
Providing and applying Two coats of wall care Putty on plastered surface and Ceiling and Walls to prepare surface even and smooth of approved make, etc complete.

13.68

-

-

... More
Providing and laying chequered tiles ofapproved qualityof size 30cmx30cm, confirming to corresponding I.S.forflooring in required position laid on a bed of1:4 cement mortar including cement float,filling joint with cement slurry cleaning curing etc. compl

8

-

-

... More
Providing and laying Antiskid Ceramic tile sof approved quality of size 30cmx30cma nd confirming toI S15622-2006(Group-BIIA) for antiskid flooring in required positionlaidonabedof1:4 cement mortar including cement float,filling joint with cement slurry cleaning curing etc. complete.

13.86

-

-

... More
Providing and laying vitrified mirror/glossy finish tile s having size 590mmto605mmx590mm to 605mm of 8to10mm thickness and confirming to IS.15622-2006 (groupBla) of approved make,shade and pattern fordadoandskirting inrequired position fixed in 1:4 cemen

22.37

-

-

... More
Providing and fixing in position powder coated aluminium louvered windows / ventilator of various sizes with powder coating as per detailed drawing and specifications including aluminium rames 80 x 38 mm x 1.22 mm box type, 5 mm thick sheet glass louvers, of approved quality etc. complete.

0.56

-

-

... More
Providing and fixing green marble of 18 to 20 mm thick for doorframe/ dado/ window boxing etc. On C.M. 1:6 including filling joints with polymer base filler nosing / moulding the sharp edges wherever necessary, curing, etc. complete.

1.86

-

-

... More
Providing and Fixing 30MM thick BOTH SIDE PRELAMINATED SOLID PANEL PVC DOOR SHUTTER consisting of frame made out of M.S tubes of 19 guage thickness and, size19x19mm for styles and15x15mm for the top and bottom rails, M.S frames hall have acoatofmetelprimer of approved make and manufacture. M.S frame shall be covered withheatmouledPVC'C'channelmadefrom 5mm (+/0.25)thick prelaminated sheet of density 600kg/cbm, ofsize30mm thickness 70mm widthout of which 50mm shall be flat and 20mm shall be tapered in 45? angle on either side for mingstiles;and 5mm thick,95 mm wide PVCsheet out of which 75mm shall be faltand 20mm shall be tapered in 45 on the inner side to form top and bottom railand 115mm wide PVC sheet out of which 75mm shall be faltand 20mm shall be tapered on both sides toform lockrail.Top, bottom and lockrailshall be provide deithersideofthepanel.Anadditional5mm(+/0.25)thickPVCstripof20mmwidthistobestuckonthebottomsideofthe'c'channelprelaminatedpanelingof5mm(+/0.25)thickPVCsheettobefittedinsidetheM.S.framewelded/sealedtothestylesandrailswith5mm(+/0.25)x30mmPVCsheetbeadingoneithersideandjoinedtogetherwithsolventcementadhesiveetc,10mmthickness(5mm(+/0.25)x2nos)20mmwidecrossPVCsheetasgapinsertfortherailandbottomrail.Doortobefixedtoframeswith3nosM.S.powdercoatedbuthingesofsize100mmx25MMx2mmusing32mmlongsteelscrewsdrilledsuitabletopassthroughboththewallsoftheM.Stube.Otherhardwaresshouldbefixedwith19x6mmsizesteelscrewsincludingfixturefasting.Complete as per direction of engineer in charge.

1.58

-

-

... More
Providing and fixing 450mmx550mm size superior type Belgium mirror with 16mm dia. nickel plated towel rod etc. complete.

1

-

-

... More
Providing and fixing 900mm high S.S.304 Grade Stainless steel railing with 40mm diameter and 1.5mm thick at top, 40mm diameter and 1.5mm thick vertical supports spacedat 1.5 mcenter to center and 8mm thick toughened glass including fabricating, fixtures, errecting, necessary welding, grinding ,finishing,buffing to stainless steelpipeetc. complete

18

-

-

... More
Plumbing

-

-

-

... More
Providing and fixing coloured glazed earthenware wash hand basin of 63 cm x 45 cm Size including cold water pillar tap / cold and hot water pillar tap brackets, rubber plugs and brass chain, stop tap and necessary pipe connection including P.V.C. waste pipe and trap up to the outside face of the wall.. Spec. No. Bd.V.30 Page No.565

1

-

-

... More
Providing and fixing C.P. pillar cock long neck with aerator of approed make including necessary sockets/union nut etc. complete. Spec. No. As Directed By Engineer In Charge.

1

-

-

... More
Providing and fixing C.P. Angular stop clock with wall flange of approved make continental including necessary sockets / union nut etc. complete. Spec. No. As Directed By Engineer In Charge.

1

-

-

... More
Providing and fixing C.P. BIB cock with wall flange of approved make including necessary sockets/ union nut etc. complete. Spec. No. As directed by Engineer in charge

1

-

-

... More
Providing and fixing H.D.P container Syntex or alike one piece moulded water tank made out of low density polythyler and built corrugation including of delivery upto destination hoisting and fixing of accessories such as inlet, outlet over flow of all tanks capacity above 1000 to 20,000 litres Spec. No. As directed by engineer incharge.

2000

-

-

... More
Providing and fixing on Walls / Ceiling / Floor 25 mm Dia. CPVC Pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Spec. No. BD.V 5 page 551 and as directed by Engineer in charge

4

-

-

... More
Providing and fixing on Walls / Ceiling / Floor 32 mm Dia. CPVC Pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Spec. No. BD.V 5 page 551 and as directed by Engineer in charge

2

-

-

... More
Providing and fixing on Walls / Ceiling / Floor 40 mm Dia. CPVC Pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Spec. No. BD.V 5 page 551 and as directed by Engineer in charge

2

-

-

... More
Providing and fixing on Walls / Ceiling / Floor 50 mm Dia. CPVC Pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Spec. No. BD.V 5 page 551 and as directed by Engineer in charge

8

-

-

... More
Providing and fixing on Walls / Ceiling / Floor 15 mm Dia. CPVC Pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Spec. No. BD.V 5 page 551 and as directed by Engineer in charge

15

-

-

... More
Providing and fixing 15 mm. dia Ball cock medium type with PVC float including sockets and necessary fittings and tested as per municipal requirements etc. complete. Spec. No. As Directed By Engineer In Charge.

15

-

-

... More
Providing and fixing 40 mm. dia Ball cock medium type with PVC float including sockets and necessary fittings and tested as per municipal requirements etc. complete. Spec. No. As Directed By Engineer In Charge.

1

-

-

... More
Providing and fixing European type wall-hung white water closet of approved make with push valve concealed type with cover plate 32mm size of approved make including soil pipe, vent pipe up to outside face of wall ,100mm dia. G.I. plug bend inlet pipe all fittings, cuttingand making good walls, floors etc. complete (

1

-

-

... More
Providing and constructing Brick Masonry Inspection Chamber 90cm x 45cm x 90cm including 1:4:8 cement concrete foundation 1:2:4 cement concrete chanels half round G.S.W.pipes, Brick Masonry, plastering from inside and C.I. lid cover of 75 kg with lid and frame fixed in cement concrete

1

-

-

... More
Providing , laying and fixing ,jointing Eco- drain 200 mm SN 4 Nu-Drain Upvc pipes or of equivalent make, manufacture as per EN 13476 or equivalent as per I.S.15328 with fittings such a bends, tees tees, coupler etc, jointing with rubber lubricant including necessary excavation, trench refilling with selective excavated materialetc.complete.

10

-

-

... More
Covid-19 Health and safety: Providing and making necessary arrangements of various essential materials and items of recommended quality and make as per guidelines of the health department required for prevention of COVID-19 pandemic in consideration of health and safety management of man power at construction site 1. Hand Sanitizer.: 50 liters 2. Disinfectant. : 30 Liters 3. Sodium Hypochlorite. : 30 KG 4. Fogging machine and Liquid for sanitization.: 1 Number 5. 3 Ply Face Mask of good quality. : 500 Numbers 6. Surgical / Latex Gloves of good quality.: 200 Pairs 7. Rubber Gloves of good quality.: 100 Pairs 8. Empty Spray Bottles 100 ml (Plastic).: 20 Numbers 9. Empty Spray Bottles 1000 ml (Plastic).: 5 Numbers 10. PPE kits. : 10 Numbers 10. Temperature Guns. : 3 Numbers 11. Face shield : 30 Numbers

1

-

-

... More
Electromaechanical work

-

-

-

... More
INSULATED PANEL Supply and Erection as per General Technical Specifications , for walls-80 mm thick PIR panels,Density: 40 ±2kg /m3 0.5 mm thick Precoated G.S. Sheet (min. 180 GSM) on both sides with polyester coating (thickness: 20~25 micron)

385

-

-

... More
INSULATED PANEL Supply and Erection as per General Technical Specifications , for walls-100 mm thick PIR panels,Density: 40 ±2kg /m3 0.5 mm thick Precoated G.S. Sheet (min. 180 GSM) on both sides with polyester coating (thickness: 20~25 micron)

421

-

-

... More
INSULATED PANEL Supply and Erection as per General Technical Specifications, for ceiling-60 mm thick PIR panels, Density: 40 ±2kg /m3 0.5 mm thick Precoated G.S. Sheet (min. 180 GSM) on both sides with polyester coating (thickness: 20~25 micron) Ceiling support system including supports for hanging/fixing ceiling structure from the roof/slab level to be included. This structure shall be ensured to be with complete thermal break and should avoid metal connection between inside and outside.

182

-

-

... More
INSULATED PANEL Supply and Erection as per General Technical Specifications, for ceiling-100 mm thick PIR panels, Density: 40 ±2kg /m3 , 0.5 mm thick Precoated G.S. Sheet (min. 180 GSM) on both sides with polyester coating (thickness: 20~25 micron) Ceiling support system including supports for hanging/fixing ceiling structure from the roof/slab level to be included. This structure shall be ensured to be with complete thermal break and should avoid metal connection between inside and outside. Additional PIR filled hat section of minimum 50 mm thicnkess beyond any metal member of the support should be considered if only metal 'T' is being considered for ceiling panel support.

475

-

-

... More
INSULATED FLOOR Supply and Erection as per General Technical Specifications Floor 100 mm XPS , min 30 kg/cu.m density. Rate for floor insulation to include supply and erection of all ancilliaries including polythene vapour barrier & two ply tarfelt as per specifications and bituminous primer, bitumin / bituminous cold compound for proper adhesion to surfaces.

505

-

-

... More
Supply & Fixing of 6~9 mm thick EPDM / Nitrile rubber on RCC slab / brick walls with suitable CPRX compound adhesive over which the insulated panels shall be fixed tightly with Nylon / FRP / Steel reinforced Nylon bolts.The bolt heads on the panels shall be covered with hat runners filled with PUF insulation as per standard practice.

80

-

-

... More
Supply & fixing of of Al foil min. 50 micron on RCC slab / brick walls with suitable CPRX compound adhesive / bitumen

85

-

-

... More
Ancillary Materials and Services - Flashings for Internal and external wall-ceiling joints and wall-wall joints as applicable or as may be required for doors or other openings. The layout showing the chamber dimensions and height is enclosed for ready reference. The flashings should be atleast 50mm x 50 mm or larger sizes with adequate overlap over any given panel-panel joint (Precoated G.S. Sheet, minimum 0.5 mm thick)

1

-

-

... More
Ancillary Materials and Services - Silicon / Polyeurathene sealant for sealing the gaps between panels and the external / internal face of the insulation panels and any other location as may be deemed suitable for proper insulation panel erection system as applicable.

1

-

-

... More
Ancillary Materials and Services - PUF/PIR chemical, adhesives,/ tapes / plastic caps etc reqd for onsite application, as may be necessary for a complete and foolproof insulation job.

1

-

-

... More
Ancillary Materials and Services -SITC of Pressure relief ports suitable for mounting on insulated panels of various thicknesses (60 mm to 100 mm) with internal heaters for room temperatures ranging from 25 deg C to (-) 10 deg C. (Fermond Soupape 2220 -Valve /Equivalent)- 2 no for each cold storage chamber.

4

-

-

... More
Ancillary Materials and Services - Making & finishing of cut outs for doors, pipes, cables, pressure ports etc as per requirement at site. Finishing would include filling with PUF/PIR & PUF/PIR foam of required density and covering with pre - coated G.I.sheet from both side of the panels to give aesthetically neat joint acceptable to Consultants / Owners. This should also include any additional Silicon sealent or any other material as required.

1

-

-

... More
Cold room 1,2 Manual Sliding type 1500 mm x 2600 mm ht x 100 mm thick PIR , manual type Providing & fixing of Insulated sliding doors (suitable for fitting on panel structure) of clear opening size & insulation thicknesses as mentioned and specifications as per General technical specifications (GTS). The doors shall be manual single leaf sliding with 0.6 mm thick SS-304 sheet or pre-coated extruded Aluminium of required thickness main frame. The door leaf shall have 0.5 mm thick PCGI sheet with min 180 GSM galvanising / S.S sheet cladding on both sides with PIR foam filled In-situ and with a density 40 ± 2 Kg/m3 (insulation thicknesses as mentioned).0.60mm thick PCGI sheet flashing to protect and reinforce the cut out opening in panel wall to be included in the cost. The sliding mechanism should be sturdy and smooth in operation complete with rail, runners, sill on the bottom etc. Rail shall be made of heavy duty aluminium alloy / SS with 45º drop & with polyethylene roller / special grade nylon arrangement runner system. The rail shall be provided with canopy / cover of 1.2 mm thick PCGI / Extruded Aluminium of required thickness. The doors shall have easily replaceable EPDM gaskets to ensure perfect hermetic sealing .

4

-

-

... More
SITC of strip curtains made of 3 mm thick transparent PVC sheet strips with 40 / 50 mm overlapping and supporting clamps. The strips shall have free swinging motion. The strip material shall be suitable for the specified low temperature application to ensure that it remains soft even at the lowest operating temperature

-

-

-

... More
cold room 1,2 Suitable for Clear opening Size: 1500mm X 2600mm ht

4

-

-

... More
Air Curtains for Pre-Cooling Chamber, staging cold room Supply & fixing of industrial type air curtains suitable for door clear opening size as mentioned and specifications given below. The Air Curtains shall incorporate centrifugal blowers made of SS / Aluminium with sealed ball bearings. The blowers shall be statistically and dynamically balanced. The motor shall be of standard make suitable for operation on single phase or three phase AC supply. The casing shall have a sturdy construction in SS304 finish. Adjustable louvers shall be provided for streamlining the air delivery.Air velocity to be in the range of 12 to 15 m/s. Proximity sensor with controller switch (limit switch) to be provided to ensure that the air curtain operates only when the door is open. Necessary fixing arrangement including sturdy brackets or base frame to bring the air curtain to the required level for proper air flow shall also be included in the cost. Necessary cabling in casing-capping / conduits as required by architects/owners from the switch points provided near the door shall also be included in the costing. Suitable for Clear opening size: 1500 mm x 2600 mm ht

2

-

-

... More
AIR COOLED CONDENSING UNITS For staging cold room 1 (General details as per PART – II - REFRIGERATION SYSTEM of GTS) Complete with Reputed approved make semi hermatic reciprocating compressor working on R449A / R448 A or other approved HFO, Air cooled condenser, Liquid receiver,Oil separator with check valve in discharge line, Base frame for mounting, H.P. / L.P.switches, Suction accumulator Vibration eliminator, Oil pr switch and pressure gauges , Sturdy MS Stand with two coats of primer and two coats of oil paint of approved colour etc. as required. Condenser coil to be designed for 10 deg C TD between ambient temperature and condensing temperature. Other Technical specifications as per General Technical specifications as mentioned in the tender. The capacity and other details shall be as follows : For staging cold room 1 Capacity: 20 KW DesignTemperature: (-)4 deg. C evap. and +48 deg.C cond. Temp Maximum ambient Temperature: 42 deg C ambient Minimum fin spacing: 2 mm Condensing unit inlet air pre-cooling system: to be included

2

-

-

... More
AIR COOLED CONDENSING UNITS For staging cold room 2 (General details as per PART – II - REFRIGERATION SYSTEM of GTS) Complete with Reputed approved make semi hermatic reciprocating compressor working on R449A / R448 A or other approved HFO, Air cooled condenser, Liquid receiver,Oil separator with check valve in discharge line, Base frame for mounting, H.P. / L.P.switches, Suction accumulator Vibration eliminator, Oil pr switch and pressure gauges , Sturdy MS Stand with two coats of primer and two coats of oil paint of approved colour etc. as required. Condenser coil to be designed for 10 deg C TD between ambient temperature and condensing temperature. Other Technical specifications as per General Technical specifications as mentioned in the tender. The capacity and other details shall be as follows : For staging cold room 2 Capacity: 23.5 KW DesignTemperature: (-)4 deg. C evap. and +48 deg.C cond. Temp Maximum ambient Temperature: 42 deg C ambient Minimum fin spacing: 2 mm Condensing unit inlet air pre-cooling system: to be included

2

-

-

... More
AIR COOLING UNITS - Air Cooling Units for cold room 1 (General details as per PART – II - REFRIGERATION SYSTEM of GTS) Technical specifications as per General Technical Specifications as mentioned in the tender. The capacity and other details shall be as follows : Make: Star coolers / GEA / Alfa Laval / Guentner / LU-VE / Thermofin / Eqvt, Model: To be Mentioned Type of Unit -Single / Twin: Single coil type Type of Refrigerant feed: HFO - DX Capacity - kW: 20 Evap. Temp. & TD ‘C’: (-)4 °C / 4 °C Coil / Fin MOC: Cu / Al Fin spacing -mm: 6 mm Fin type: Plate Finned coil length -m: To be Mentioned Total fan capacity of each unit– CMH: 23000 External sp. Wg, mm: 7 No of Fans/Unit: 2/3 Fan Motor -kW each: To be Mentioned Air throw -m: 15 m Drain pan insulation: Required Drain pan heating: Not required Type of Defrosting: Electrical Fan peripheral heating: Not required Suitable Supporting structure from primary support at roof level or mounting stand (if supporting from floor level) to be considered in the costing as well.

2

-

-

... More
AIR COOLING UNITS - Air Cooling Units for cold room 2 (General details as per PART – II - REFRIGERATION SYSTEM of GTS) Technical specifications as per General Technical Specifications as mentioned in the tender. The capacity and other details shall be as follows : Make: Star coolers / GEA / Alfa Laval / Guentner / LU-VE / Thermofin / Eqvt, Model: To be Mentioned Type of Unit -Single / Twin: Single coil type Type of Refrigerant feed: HFO - DX Capacity - kW: 23.5 Evap. Temp. & TD ‘C’: (-)4 °C / 4 °C Coil / Fin MOC: Cu / Al Fin spacing -mm: 6 mm Fin type: Plate Finned coil length -m: To be Mentioned Total fan capacity of each unit– CMH: 27000 External sp. Wg, mm: 8 No of Fans/Unit: 2/3 Fan Motor -kW each: To be Mentioned Air throw -m: 18 m Drain pan insulation: Required Drain pan heating: Not required Type of Defrosting: Electrical Fan peripheral heating: Not required Suitable Supporting structure from primary support at roof level or mounting stand (if supporting from floor level) to be considered in the costing as well.

2

-

-

... More
Refrigeration Piping, Fittings & Valves (General details as per PART – II- REFRIGERATION SYSTEM of GTS) The piping shall be of refrigeration quality The piping shall be of refrigeration quality seamless copper tubes and the valves shall be brassomatic / Henry or equivalent make. The piping shall be included accessories such as filter, drier, sight glass, heat exchanger, suction lineaccumulator etc. as per P & I diagram approved by Consultant. Adequate number of supports shall be included. The piping shall be supported at distances of maximum 1.5 m from each other with suitably placed GS threaded rods of minimum 6 mm thickness when outside the chamber and piping shall be run on cable trays of size suitable to fit the pipes including insulation. Common cable trays can be considered depending on the suitability at site, however the same shall be acceptable to the consultant / owner. Overall, the piping execution shall ensure proper workmanship and a neat and tidy work is expected with straight horizontal and vertical lines and proper supporting. Under no circumstances shall any additional charges be demanded by the contractor for ensuring the same. The suction and discharge lines shall be designed for a maximum pressure drop corresponding to 1.1 deg. C drop in saturated evaporating and condensing temperatures. The liquid line shall be designed for maximum pressure drop corresponding to a drop 0.5 to 1 deg. C in saturation temperature. The piping shall be designed with proper slope in the direction of Refrigerant flow and to ensure proper oil return to the compressor and should be installed with adequate supports to avoid undue vibration. The piping should be thoroughly cleaned as per standard practice prior to installation. Refrigeration piping,fittings,valves,interconnecting condensing & evaporator unit complete with standard controls & accessories, supports as may be required shall be included in cost.layout drawing showing proposed location of condesing units is atttached for your reference.

1

-

-

... More
Suction line insulation (General details as per PART – II- REFRIGERATION SYSTEM of GTS) Suction line insulation with EPDM/ XLPE/Equivalent insulation with minimum 28G Aluminium foil Clading in the covered areas and Weatherproof Clading in areas exposed to sunlight and is uncovered ; e.g. Woven glass cloth with epoxy coating or Armacheck GC/equivalent Clading with suitable fittings and Adhesives.Alternatively,Fevicol Weather protect coat applied as per manufacturers recommendation may be used for entire insulton protection. Thickness - 25mm Insulation supports shall be half round or full round heavy duty PVC pipe sections of relevant size which shall be atleast 150 mm in length and shall be placed below every support. This is essentially ensuring that the insulation compression at the support is at the minimum.

1

-

-

... More
Drain piping with rigid U-PVC pipe from A.C. units to to suitable drain point complete with 'U' Traps for each cold room and supports.Drain lines (inside the chambers) to have 10 mm EPDM / Eqvt. insulation with factory backed Aluminium foil.Individiual Drain outlet line from ACU pipe size shall be same as the drain outlet of ACU and further the header shall be at least one size higher than the drain outlet connection size. Further, higher sizes may be considered as per the consultants/owner's recommendation

1

-

-

... More
Controls and Instruments (a) Thermostatic expansion valves for each ACUs (b) Digital temperature indicator cum controllers (0 to 50 deg. C range) (c) Liquid line solenoid valves, DANFOSS / SPORLAN /EQVT make (d) Digital temperature indicator (minus 20 to 50 deg. C range), for A.C. units to be placed outside the each cold rooms in ante-room area. (e) Digital RH indicator (0 to 100 % range) for A.C. units to be placed outside the each cold rooms in ante-room area. Only for pre-cooling ,staging cold room ACUs

1

-

-

... More
First charge refrigeration gas and oil etc. as required upto commissioning and final handling over of plant.

1

-

-

... More
Painting of equipment/piping / piping supports etc. as per standard colour codes with initial coat of red oxide primer and two coats of synthetic enamel paint .

1

-

-

... More
Humidification system for pre-cooling chambers complete with Industrial type Ultrasonic Humidifier, U-PVC water piping from the tanks to humidifier unit, fitting ,valves, atomizer nozzles (if requird), solenoid valves with strainers and humidistats etc. as may be required to maintain the relative humidity in the design range for Pre-Cooling Chambers. Also consider heavy duty PVC piping for air delivery into the cooling area for a release of humidified air into the main air stream, at atleast 1 m distance from the partition panel Humidifier Capacity: 12 Lit/hr.

2

-

-

... More
Electrical work for Refrigeration System (General details as per PART – II A- REFRIGERATION SYSTEM of GTS) Electrical control panel shall be manufactured as per specifications menioned in GTS and approved GA drawings. The Panel shall be comprising of following: a) Suitable Incomer of ACB / MCCB / MCB / RCBO of required rating and as per enclosed specification and approval. b) All Suitable rating MCB's, MPCB's, RCBO's, starters, relays, etc for various motors as used in the equipments shall be selected as per type 2 co ordination chart provided by the manufacturer. c) MCBs for control circuit d) Each starter shall be provided with facility for remote Start/Stop operation. This panel shall be located in the plant room (on terrace level) and shal have weather proof enclosure with suitable MCB's/RCCB's/RCBO's near the condensing unit. Job includes Electrical Power cabling (armoured) to all the outgoing feeders along with PVC medium duty Conduit/ pregalvanised Cable tray's, etc as per requirement and power cabling shall be as per specifications given in GTS. Control wiring with PVC insulated copper conductor with conduits as required for the refrigeration and other systems as defined here. Local Protection through MCB's/RCCB's/RCBO's for A.C. units, fan motors and other remotely located motors shall be part of the job.The Job shall also include earthing for control panel and various motors etc. using required sizes earthing conductors using GI/Cu earthing strips or Cu Conductors, all as per IS.The control panel shall have provision for interlocking of various equipment as per standard practice.

1

-

-

... More
Miscellaneous Items a) Vibration isolators for condensing units, supporting rods / Frame for A.C. Units with insulation, steel structure for mouting condensing units etc. as may be required b) Minor structural openings in walls / panels etc for piping, cabling etc. and finishing. c) 2000 lit water tank along with water pump as necessary for lifting water to the tank or lifting water from the tank depending on tank location ,UPVC piping, fittings,valves etc as may be required for condenser inlet air-precooling system. Condenser air pre-cooling system shall have automatic operation with water line sonenoid valves for each individual condensing unit and there shall be an interlock with the conensing unit start/stop as well as the ambiend air temperature wherein the air precooling system starts only after the ambient air temperature crosses 33 deg C and switches off when ambient goes beloe 33 deg C.

1

-

-

... More
Charges for Installation, Testing and Commissioning Installation, testing and commissioning of all above equipment / material as per the system requirement. All tools and tackles, welding machines, welding rods and gases etc. required for fabrication, erection, testing and commissioning shall be arranged by the contractor at his cost. The plant shall be erected, tested, commissioned as per Consultant's approved drawings / specifications and instructions to his and Employer's satisfaction. The refrigeration system shall be pressure tested and evacuated as per standard practice before charging the refrigerant. The water lines shall also be pressure tested as per standard practice. The plant shall be run for a period of three days after commoissioning by the contractor, to assess the plant performance. The contractor shall provide 3 hard copies of operation & maintenance for the plant along with as built drawings. The contractor shall also arrange the training of the operating staff for proper operation & maintenance of the plant (included in above rates)

1

-

-

... More
Supply, Installation, Testing & Commissioning of 3 C x 95 sq.mm. 11 KV XLPE insulated, round armoured, aluminium conductor cable, through provided RCC pipe.

10

-

-

... More
Supply & Installation of heat shrink type 11 KV H.T. termination kits for 3 C x 95 sq.mm. XLPE ( Indoor type ).

1

-

-

... More
Supply & Installation of heat shrink type 11 KV H.T. termination kits for 3 C x 95 sq.mm. XLPE ( Outdoor type ).

1

-

-

... More
Supply, Installation, Testing & Commissioning of earthing station using pipe in pipe earthing electrode with complete system as per specs. Including boring, civil work, chamber etc. Earthing shall be carried out as described in IS-3043-1960 code. Pipe in pipe earthing electrode system shall be as per enclosed technical specifications. The entire earthing system should be executed as per system supplier’s instructions. The Earthing Chamber with all the necessary material required for earthing shall be in Contractors scope. Testing of the Earthing system shall be as per specification & results shall be submitted to Engineer-in-Charge duly signed by contractor and authorized representative. 2 meters Length Earthing Electrode

5

-

-

... More
Same as above but electrode length shall be 3 mts.

3

-

-

... More
Supply & Installation of 32 x 6 mm Galvanized Iron earthing strip & Conductor shall be of High Conductivity. All Necessary Accessories required for installation of Earthing Strips such as Porcelain Insulators, Clamps, Saddles, Hardware, etc will be included in the rate. The Earthing strips connections shall be used as per the provided earthing schedule.

123.62

-

-

... More
Same as above with Earthing strip of 25 x 3 mm Copper.

60

-

-

... More
Supply & Installation of 6" dia RCC half round pipe for covering HT/LT cables. Rate shall be inclusive of excavation, back filling and civil work for chambers.

1

-

-

... More
Supply & Installation of 6" dia RCC round pipe for HT/LT XLPE cables laid for Road Crossing. Rate shall be inclusive of excavation, back filling and civil work for chambers.

1

-

-

... More
Supply & Installation of 146/150MM dia round HDPE Pipe for LT cables. Rate shall be inclusive of excavation, back filling and civil work for chambers.

1

-

-

... More
Supply & Installation of 50MM dia round HDPE Pipe for LT cables. Rate shall be inclusive of excavation, back filling and civil work for chambers.

1

-

-

... More
Liaisoning Work with Electricity board & Electrical inspector or any other government authority for change of sanction & Contract load as per new requirement of electrical load. Job involves preparation of necessary documents with drawings, as required for load application, submission of document files with necessary officials / departments, follow-up with all concerned departments for getting required load sanctioned. Obtaining work completion report from Electrical inspector & board officials. Client (Owner) will make all official payments as per the requirement of Electricity board.

1

-

-

... More
Supply & Installation of printed Danger Board/instruction chart for treating persons suffering from electric shock, printed in English & Marathi and duly laminated complete.

6

-

-

... More
Providing Round bottom fire bucket of 9 Litres capacity as per IS : 2546 made out of 24 gauge G.I. sheet with extra handle at bottom duly painted white inside and red outside with FIRE Mark, on provided stand/ wall hook complete

6

-

-

... More
Providing Floor mounting stand for keeping 4 Nos. of FIRE buckets 1500mm in length, 900mm in height frame made out of 30x30x4 mm angle iron with cross supports for legs, welded with 4 hooks and duly painted with one coat of red lead and two coats of silver paint complete.

1

-

-

... More
Supplying and erecting wall hook 225mm projection for keeping fire buckets made out of 15 mm dia. M.S. Rod grouted in wall to a depth of minimum 15cms complete.

2

-

-

... More
Providing pair of duly tested rubber hand gloves as per IS :47705 suitable for working upto 22 kV supply complete.

2

-

-

... More
Supplying standard first aid box with necessary antiseptic cream, medicine for use on wounds due burn, crepe bandage, gauge bandage, medicated ready to use bandage (Band-Aid) adhesive tape for medicinal use, scissors, anti-septic solution, etc. (All above contents shall be of standard makes)

2

-

-

... More
Supplying and fixing PVC synthetic elastomer electrically insulating mat with class A insulation conforming to IS: 15652 – 2006 & CPRI tested having 2 mm thickness upto 3.3 kV

5

-

-

... More
Supplying and erecting D.C.P. type fire extinguisher 6 kg capacity cartridge type with gun metal cap 150 gram CO2 gas cartridge, powder and brackets conforming to IS 2171-1985/ IS 15683 and complete erected with necessary clamps made from 50x6 mm M.S. flat with nuts & bolts grouted in wall complete.

5

-

-

... More
Supplying and erecting ABC powder type fire extinguisher as per IS : 13849 /15683 of 6 kg capacity with necessary clamp for erection on wall.

5

-

-

... More
Supply, Installation, Testing & Commissioning of outdoor type MCCB panel to be installed near transformer & comprising of following:- 500 Amp. 4 pole 36 KA MCCB with Microprocessor based LSIG protection, with rotary door handle, spreader links, phase barrier etc - 1 No. 96 sq.mm. 0-500 V digital voltmeter with built-in selector switch. - 1 No. 96 sq.mm. 0-500 Amp. digital ammeter with built-in selector switch & CTs. - 1 No. Indicating lamps LED type - 1 Lot. Control MCB - 1 Lot. Neutral Link - 1 Lot. Space heater with thermostat & MCB for protection - 1 No. 2 KVAr Fixed type APP/Gas capacitor banks - 1 No. having 6 Amp. TP 10 KA MCB, capacitor duty contactor suitable for 2 KVAr bank - 1 No., 3 KVAr Fixed type APP/Gas capacitor banks - 1 No. having 10 Amp. TP 10 KA MCB, capacitor duty contactor suitable for 3 KVAr bank - 1 No. 1 pole two way selector switch for capacitor Start/Stop action - 2 Nos, electronic timer, ON/OFF indication. This bank will remain on as long as EB supply is available. Ventilation Lovers with powder coated MS filters to be provided in panel. Notes: Panel shall be suitable for outdoor installation & having double door in the front side. Breaker operating parts & meters shall be accessible after opening of front door only. Front door will have a Acrylic window cutout, so that the Meters & Indications are visible. Panel shall be provided with angle frame of 500 mm height made from 50x5 M.S. angle and matching covers from three sides. Aluminium busbar of 500 Amp. @ 0.8 Amp / mm Current Density & 50 degree C ambient temperature.. Cable entry at bottom & shall be suitable for cable as mentioned in SLD.

1

-

-

... More
Supply, Installation, Testing & Commissioning of Main PCC made as per specifications and comprising of following:- Incoming:- 500 Amp. 4 pole 36 KA MCCB with Microprocessor based LSIG protection, with rotary door handle, spreader links, phase barrier etc - 2 Nos., 125 Amp. 4 pole 36 KA MCCB with Microprocessor based LSIG protection, with rotary door handle, spreader links, phase barrier etc - 1 No, 1 No., 96 sq.mm. 0-500 V digital voltmeter with built-in selector switch. 3Nos., 96 sq.mm. 0-500 Amp. digital ammeter with built-in selector switch & CTS. 2Nos., 96 sq.mm. 0-125 Amp. digital ammeter with built-in selector switch & CTS. 1No., 500 Amp. 4 pole Automatic Transfer Switch with NO/NC Contcts, Multi function energy meter 1.0 class with RS 485 communication port & CT's. 3 Nos., 500/5 Amp. class 1.0 CT for APFC relay input. 1 No., Phase indicating lamps. 1 Lot., MCCB ON/OFF/Trip indication. 1 Lot., Control fuses. 1 Lot., Neutral Link. 1 Lot., Emergency Stop Push Button. 1 Lot., 6 Amp. 4 pole 10 KA MCB. 2 Nos., 6 Amp. 2 pole 10 KA MCB. 3 Nos, Outgoing:- 320 Amp. 4 pole 36 KA MCCB with adjustable thermal, fix magnetic release, with rotary door handle, spreader links, phase barrier etc. 1 No., 200 Amp. 4 pole 36 KA MCCB with adjustable thermal, fix magnetic release, with rotary door handle, spreader links, phase barrier etc. 1 No.,125 Amp. 4 pole 36 KA MCCB with adjustable thermal, fix magnetic release, with rotary door handle, spreader links, phase barrier etc. 2 Nos., 63 Amp. 4 pole 36 KA MCCB with adjustable thermal, fix magnetic release, with rotary door handle, spreader links, phase barrier etc. 1 No., 63 Amp. 4 pole 10 KA MCB. 1 No., 40 Amp. 4 pole 10 KA MCB. 1 No., 32 Amp. 4 pole 10 KA MCB. 1 No., 25 Amp. 2 pole 10 KA MCB. 3 Nos., Electronic Energy meter 1.0 class with RS 485 communication port & CT's. 5 Nos., Space heater with thermostat & MCB for protection. (In each section) Ventilation fans with filters & MCB for protection. (In each section). APFC Section:- 50 KVAr bank. 3 Nos., 25 KVAr bank. 1 Nos., 12.5 KVAr bank. 2 Nos. 10 KVAr bank. 2 Nos., 5 KVAr bank. 2 Nos. Notes:- Provision for RYB Indications of EB & DG, shall be given in terminal blocks. Solar feeder & APFC section shall be ON as long as EB supply is available. Selection of MCCB shall be as per approved makes given along with this enquiry. Please refer SLD & ensure that all releases are as per specifications. Feeders having MCB's as outgoing will have double door & front doors will have a Acrylic window cutout. Each bank to have MCCB with adjustable thermal, fix magnetic release, spreader links, phase barrier etc. all MCCB ratings shall be as shown in SLD, Capacitor Duty Contactor , APP or gas filled capacitor, Start/Stop Push Buttons, On/Off indication, Auto/Manual Selector Switch, Electronic Timer. 12 point intelligent type APFC relay will ensure switching of appropriate bank to maintain P.F. at 0.999 or unity. Aluminium busbar of 500 Amp. @ 0.8 Amp / mm Current Density & 50 degree C ambient temperature. Panel shall be front access only with cable entry at top. Panel will have uniform depth throughout the length of the panel. Proper shrouding shall be provided on all live terminals. Maximum height of panel shall be 2375 mm including base frame of 75 mm.

1

-

-

... More
Supply, Installation, Testing & Commissioning of 3.5 C x 300 sq.mm, 1.1 KV grade, Stranded aluminium conductor, XLPE insulated, armoured, PVC outer sheathed cables conforming to IS:7098 ( Part-I ). The rates shall be inclusive of laying of cable in provided Trench/Pipe/Cable Tray. Termination of cables using double compression gland, crimping type lugs, etc. Each termination shall include supply of all necessary components, accessories, including double compression cable gland, cable lugs (crimping type) and consumables to make a complete termination in such a way that no live parts of the terminal and connecting lugs are exposed. While making termination, all other protection arrangement shall also be ensured. The cable tagging with proper ferrules shall be supplied & installed by the Contractor as part of cable termination work. Testing of the cables shall be as per specification & results shall be submitted to Engineer-in-Charge duly signed by contractor and authorized representative. Before Commissioning of cables Contractor need to check for physical damages & proper connection of all the terminals.

60

-

-

... More
Same as above but with 3.5 C x 185 sq. mm. Stranded Aluminium Conductor.

50

-

-

... More
Same as above but with 3.5 C x 50 sq. mm. Stranded Aluminium Conductor.

1

-

-

... More
Same as above but with 4.0 C x 6 sq. mm. Copper multi stranded.

30

-

-

... More
Same as above but with 4.0 C x 4 sq. mm. Copper multi stranded.

1

-

-

... More
Same as above but with 3.0 C x 6 sq. mm. Copper multi stranded.

1

-

-

... More
Same as above but with 3.0 C x 2.5 sq. mm. Copper multi stranded.

50

-

-

... More
Same as above but with 2.0 C x 2.5 sq. mm. Copper multi stranded.

1

-

-

... More
Supply & Installation of 4.0 C x 6 sq. mm 1.1 KV grade, Multi Stranded Copper conductor, PVC insulated, PVC outer sheathed cables conforming to IS:694 (1990). The rates shall be inclusive of laying of cable in provided Trench/Pipe/Conduit/Cable Tray. Testing of the cables shall be as per specification & results shall be submitted to Engineer-in-Charge duly signed by contractor and authorized representative. Before Commissioning of cables Contractor need to check for physical damages & proper connection of all the terminals.

1

-

-

... More
Same as above but with 4.0 C x 4.0 sq. mm. Copper multi stranded.

1

-

-

... More
Same as above but with 3.0 C x 2.5 sq. mm. Copper multi stranded.

75

-

-

... More
Termination of 4.0 C x 6 sq. mm, LT copper flexible cables using PVC cable gland of IP65, crimping type Copper lugs, etc. Each termination shall include supply of all necessary components, accessories, including PVC cable gland, cable lugs (crimping type) and consumables to make a complete termination in such a way that no live parts of the terminal and connecting lugs are exposed. While making termination, all other protection arrangement shall also be ensured. The cable tagging with proper ferrules shall be supplied & installed by the Contractor as part of cable termination work.

1

-

-

... More
Same as above but with 4.0 C x 4.0 sq. mm. Copper multi stranded.

1

-

-

... More
Same as above but with 3.0 C x 2.5 sq. mm. Copper multi stranded.

4

-

-

... More
Supply & Installation of 300 x 75 mm, Perforated type cable trays made out of 16 G CRCA sheet & Hot Dipped galvanized, with support at every 1.5 mt. interval using M.S. angle of size 40x40x5 mm Or Using Suspension GI rods. M.S. Support shall be painted with two coats of red oxide primer & two coats of silver paint. All necessary accessories required for installation of cable trays such as Cable Tray Supports, Clamps, Flat Strips, Joints, Hardware, etc shall be included in Installation rate.

1

-

-

... More
Same as above but of size 200 x 75 mm.

30

-

-

... More
Supply & Installation of 300 x 20 mm, cable tray cover made out of 18 G CRCA sheet & Hot Dipped galvanized, with all necessary accessories required for installation of cable tray covers such as Clamps, Flat Strips, Joints, Hardware, etc shall be included in Installation rate.

1

-

-

... More
Same as above but of size 200 x 40/50 mm.

10

-

-

... More
Supply, Installation, Testing & Commissioning of conventional spike type air termination suitable to carry lightning stroke made up of heavy gauge 40 mm dia copper pipe of standard length with 5 Nos. copper spikes fixed on copper ball as air terminals duly threaded in copper pipe erected on 5 meters height, The Lightning protection includes the Lightning counter comprising of digital display in an IP 67 enclosure with the minimum sensitivity of 1500A & maximum capacity of 220 KA counter & it should be tested as per IS/IEC, The Job also includes supporting mast using Galvanized Iron pipe of 3 meter length plus 2 meter pipe of FRP complete with base plate, Guy rope wires, Insulator, Clamps, Fasteners, Fan Hooks, hardware, etc.

2

-

-

... More
Supply, Installation, Testing & Commissioning of Primary light point wiring with 1.5 sq.mm. PVC insulated FRLS multistranded copper conductor wires, through PVC conduit concealed or surface mounted on ceiling/wall, point shall be controlled by 6 A modular type switch, with concealed/surface box, modular surface plate, ceiling rose/holder etc.

24

-

-

... More
Supply, Installation, Testing & Commissioning of Secondary light point wiring with 1.5 sq.mm. PVC insulated FRLS multistranded copper conductor wires, through PVC conduit concealed or surface mounted on ceiling/wall, point shall be controlled by 6 A modular type switch, with concealed/surface box, modular surface plate, ceiling rose/holder etc.

16

-

-

... More
Same as above but control shall be two way.

1

-

-

... More
Supply, Installation, Testing & Commissioning of fan point wiring with 1.5 sq.mm. PVC insulated copper conductor FRLS wires, through PVC conduit, concealed or surface mounted on ceiling/wall, point shall be controlled by 6 A modular type switch & step type electronic fan regulator with concealed/surface box, modular surface plate etc.

1

-

-

... More
Same as above but on lighting switch board ( Half Pt.).

5

-

-

... More
Supply, Installation, Testing & Commissioning of 6 Amp. socket point wiring with 2x1.5+1x1.0 sq.mm.PVC insulated copper conductor FRLS wires, through PVC conduit, concealed or surface mounted on the ceiling/wall, with modular type 6 Amp. switch & 5 pin socket, concealed/surface box, modular surface plate etc.

1

-

-

... More
Supply, Installation, Testing & Commissioning of 6 A sockets with modular type switches, concealed/surface box, modular surface plate etc., without any wiring & conduit ( wiring & conduit will be measured in mains ).

1

-

-

... More
Supply, Installation, Testing & Commissioning of 6/16 A socket point wiring with 2x2.5+1x1.5 sq.mm.PVC insulated copper conductor FRLS wires, through PVC conduit, concealed/surface mounted on the ceiling/wall, with modular type 16 Amp. switch & 6/16 A socket, concealed/surface box, modular surface plate etc.

1

-

-

... More
Supply, Installation, Testing & Commissioning of 6/16 A socket point with modular type switches, concealed/surface box, modular surface plate etc., without any wiring & conduit (wiring & conduit will be measured in mains ).

4

-

-

... More
Supply, Installation, Testing & Commissioning of Bell point wiring with 1.5 sq.mm, Bell push button, Bell buzzer all modular typr, PVC insulated copper conductor FRLS wires, through PVC conduit, concealed/surface mounted on the ceiling/wall, with modular type bell push and reset type bell with indicator.

1

-

-

... More
Supply, Installation, Testing & Commissioning of telephone point wiring with 2 pair telephone wire, through provided PVC conduit, concealed/surface mounted on the ceiling/wall with modular type RJ11 telephone socket, concealed/surface box, modular surface box etc. ( Telephone wire & PVC conduit will be measured separately ).

1

-

-

... More
Supply, Installation, Testing & Commissioning of TV point wiring with RG 6 co-axial cable, through provided PVC conduit, concealed/surface mounted on the ceiling/wall, with modular type TV socket, concealed/ surface box, modular surface plate etc. (RG 6 cable & PVC conduit will be measured separately ).

1

-

-

... More
Supply, Installation, Testing & Commissioning of data outlet sockets with CAT 6 UTP cable, through provided PVC conduit, concealed/surface mounted on the ceiling/wall, with modular type RJ 45 data outlet socket, concealed/surface box, modular surface plate and connection at both ends. ( CAT 6 UTP cable & PVC conduit will be measured separately ).

1

-

-

... More
Supply & Installation of 25mm medium duty PVC conduit with standard accessories and to be used for concealed / surface mounted on the ceiling/wall.

100

-

-

... More
Same as above but with 32 mm

1

-

-

... More
Supply & Installation of 25 mm wire reinforced type flexible PVC conduit with PVC glands on both sides to be used for flexible copper wires / cables.

20

-

-

... More
Same as above but with 32 mm

1

-

-

... More
Supply, Installation, Testing & Commissioning of mains / sub-main wiring using FRLS type wires of 2x2.5 sq.mm. + 1x1.5 sq.mm. PVC insulated, multistranded copper conductor through existing PVC conduit. ( Measurement of conduit & wires shall be separate ).

100

-

-

... More
Same as above but with 2x4.0 sq.mm. + 1x2.5 sq.mm.

1

-

-

... More
Same as above but with 6.0 sq.mm

50

-

-

... More
Same as above but with 4.0 sq.mm

1

-

-

... More
Same as above but with 2.5 sq.mm

1

-

-

... More
Supply, Installation, Testing & Commissioning of telephone wires of 2 pair with 0.5 mm dia. through existing PVC conduit.

1

-

-

... More
Supply, Installation, Testing & Commissioning of Jelly filled armoured telephone cable of 10 pair with 0.5mm dia liad through existing HDPE pipes

1

-

-

... More
Supply & Installation of 10 pair krone type telephone junction box.

1

-

-

... More
Supply, Installation, Testing & Commissioning of Co-axial cable low voltage grade RG-11 through existing PVC conduit.

1

-

-

... More
Supply, Installation, Testing & Commissioning of CAT 6 UTP data cable through existing PVC conduit.

1

-

-

... More
Supply & Installation of 100x50 mm PVC plastic trunking with flexible cover, base joint, aluminium clip on partition, end caps, internal angle, clips etc.

1

-

-

... More
Supply & Installation of 'B' grade GI pipe down rod duly painted for fan complete erected with PVC three core flexible cable of 1 sqmm copper PVC wire.

1

-

-

... More
Supply, Installation, Testing & Commissioning of 4 way PPI MCB DB with double door, comprising of following: Incoming : 25 A 4 pole MCB 10 KA 1 No. 25 A DP RCCB 30 mA Hpi type. 3 Nos. Outgoing : 10 A 1 pole MCB. 10 KA. 6 Nos.

1

-

-

... More
Supply, installation, testing & commissioning of 8 way SPN MCB DB with double door, comprising of following: Incoming : 25 A DP RCBO 30 mA Hpi type. 1 No. Outgoing : 10 A 1 pole 10 KA MCB. 4 Nos.

1

-

-

... More
Supply, installation, testing & commissioning of 8 way SPN MCB DB with double door, comprising of 25/32 A FP MCB 10 KA 2 Nos.

1

-

-

... More
Supply, Installation, Testing & Commissioning of MCB & socket boxes of IP 65 annd having 16 Amp. DP MCB 10 KA with 16 Amp. 1 Ph. 3 pin Socket & 32 Amp. FP MCB 10 KA with 32 Amp. 3 Ph. 4 wire with E socket. PVC Box shall be combine for both the sockets.

1

-

-

... More
Supply, Installation, Testing & Commissioning of MCB & socket boxes of IP 65 and having 16 Amp. DP MCB 10 KA with 16 Amp. 1 Ph. 3 pin Socket & 16 Amp. FP MCB 10 KA with 16 Amp. 3 Ph. 4 wire with E socket. PVC Box shall be combine for both the sockets.

2

-

-

... More
Supply, Installation, Testing & Commissioning of 6 to 32 A DP MCB with MS box.

1

-

-

... More
Supply, Installation, Testing & Commissioning of IP 65, PVC Junction box with 4way connectors & earthing terminal inside.

1

-

-

... More
Supply, Installation, Testing & Commissioning of IP 65, PVC Junction box with 2way connectors & earthing terminal inside.

4

-

-

... More
Supply, Installation, Testing & Commissioning of 39/40 Watt LED Capsule type IP 65 protection, suitable for surface mounting. System Efficacy 90, Colour Temp 6500K, CRI Value minimum 80, Operating Temperature is 0 Deg. Driver having voltage range of 120 - 300 Volts, THD less than 10%, P.F. greater than 0.95, surge protection =2.5 KV, inbuilt over voltage & under voltage protection. Complete with mounting bracket suitable for Surface mounting, wiring etc.

6

-

-

... More
Supply, Installation, Testing & Commissioning of 20 Watt LED Capsule type IP 65 protection, suitable for surface mounting. System Efficacy 90, Colour Temp 6500K, CRI Value minimum 80, Operating Temperature is 0 Deg. Driver having voltage range of 120 - 300 Volts, THD less than 10%, P.F. greater than 0.95, surge protection =2.5 KV, inbuilt over voltage & under voltage protection. Complete with mounting bracket suitable for Surface mounting, wiring etc.

32

-

-

... More
Supply, Installation, Testing & Commissioning of 15W LED Recess mounted Round Downlighter, 6500K, IP20, System Efficacy 90, CRI Value minimum 80, Driver having voltage range of 140 - 280 Volts, THD less than 10%, P.F. greater than 0.95, surge protection =2.5 KV, inbuilt over voltage & under voltage protection.

1

-

-

... More
Supply, Installation, Testing & Commissioning of 6W LED Surface mounted Round Downlighter, 6500K, IP20, System Efficacy 90, CRI Value minimum 80, Driver having voltage range of 140 - 280 Volts, THD less than 10%, P.F. greater than 0.95, surge protection =2.5 KV, inbuilt over voltage & under voltage protection.

1

-

-

... More
Supply, Installation, Testing & Commissioning of 7 watt (Colour Temp 5700/6000K)direct fitting LED bulbs.

1

-

-

... More
Supply, Installation, Testing & Commissioning of wall mounted 70 watt LED Street Light, IP65 protection, luminaire with ADC housing & clear cover, Wall mounting bracket and accessory suitable for outdoor installation. System Efficacy 100, Colour Temp 6500K, CRI Value minimum 80, Driver having voltage range of 110 - 290 Volts, THD less than 10%, P.F. greater than 0.95, surge protection = 4 KV, inbuilt over voltage & under voltage protection. Mounting height of the fitting will be around 9.0 meters.

2

-

-

... More
Supply, Installation, Testing & Commissioning of 1200 mm sweep 5 star rated ceiling fan with double bearing complete with wiring etc.

1

-

-

... More
Supply, Installation, Testing & Commissioning of 225 mm sweep fresh air cum exhaust fan with bird screen.- cfm for ventilation fans is 425 (±10%)

1

-

-

... More
Supply, Installation, Testing & Commissioning of 375/380 mm sweep heavy duty exhaust fan with bird screen.- cfm for ventilation fans is 1470 (±10%)

1

-

-

... More
Supply, Installation, Testing & Commissioning of 450 mm sweep heavy duty exhaust fan with bird screen.- cfm for ventilation fans is 2650 (±10%)

1

-

-

... More
Supply, Installation, Testing & Commissioning of audio, visual alarm system for cold storage rooms. Job involves solid state Annunciator with hooter & enclosure,30 mins power backup, installed in occupied area, stay-put type push button station in each cold rooms / pre cooling rooms, cabling from cold rooms / pre cooling rooms to Annunciator. Job involves following items. 4 points Annunciator - 1 No Stay-put type push buttons. - 2 Nos. 2Cx0.75 sq. mm.Copper Flexible multi stranded cable. - 60 Mtrs Medium duty PVC conduit of 25 mm size with standard accessories. - 50 Mtrs

1

-

-

... More
Pallets Dimensions: 1000mm X 1200mm X 150 mm approx. ht Colour: as approved by client Pallet type: four side fork opening Weight carrying capacity: 1500 Kg Suitable to use with all kind of material handling equipments including hand pallet trucks etc. Working Temperature range: (-) 25 deg C to (+) 10 deg C heavy duty type, Top Deck : Perforated MOC Shall be food grade plastic/HDPE and shall have excellent impact strength and high compression resistance.

100

-

-

... More
Overhauling of Machineries for 1 precooling chamber, 4 cold rooms ,ante-room , transformer, DG sets, HT/LT/APFC panels and other electrical system, dock,grading sorting line and overall any activity not mentioned but needed to carry out utilizing the equipment in effective manner. It is recommended that bidder shall visit the site and get the idea of quantom of work before quoting.

1

-

-

... More
The details of the exisiting machinery is as follows, • PRE-COOLING CHAMBER:1 no, CDU (2 nos), Air Handling Unit 43 kW capacity, water pump: 1 x 3 Kw, 1 no • Cold Storage 1,2,3,4: CDU: air cooled condensing unit 1 no for each room., Air Cooling Unit: 13.5 KW each unit • Ante-room: Air cooled condesing nuit and indoor unit 1 nos • Evaporative air cooling units: Qty-2 nos • Air curtains, QTY: 13 Nos. • Grading Sorting Lines • Transformer: 200 KVA • DG set: 200 KVA • 11 KV Outdoor type MCCB panel • Main PCC panel • APFC panel:microcontroller based. • Lighting fixtures: internal as well as external street lighting of different wattage

-

-

-

... More
Scope of Work for Refrigeration System: • Checking of operational log readings recorded by operators during the previous month.& Discussion operational problems, if any, with maintenance/operation staff. • Checking the actual performance of the machines and Checking & correcting the set parameters, if required. • Carrying out minor repairs. Replace minor parts ,if required. • Making recommendations to client for smooth & trouble free operation of the machines. • Cleaning & combing of ACU’s fins, suction filters, driers, pump ,strainers etc. •ACU fan & motor- routine & preventive maintenance • To check oil level in the compressor, if less then oil to be charged in to the compressor. • Check liquid sight glass to determine the shortage of refrigerant if any / to check moisture contained in the system. Top up if required. • Inspect system for visible signs of leaks. If found, attend the leaks. If any brazing work involved should be carried out by the contractor at his cost • Inspect & adjust, if required, all safety controls. • carrying out calibration of gauges, temperature , RH sensors etc, wherever caliberation time frame has exceeded • Inspect the condition of refrigerant and drain pipe insulation (drain pipe insulation wherever applicable).To be replaced if found not in good condition. • Condenser inlet air pre-cooling system - to be cleaned, pump repaired (if required), pipig cleaned and other routine and preventive maintenance.

-

-

-

... More
Scope of Work for Insulated Sandwich Panels: • Insulated Panel Structure: Filling of silicon sealant as & where required to stop air leakages if any. • Floor Insulation – checking for gaps created between civil floor and wall insulation and sealing the same with silicon sealant / PUF filling depending on the size of the gap, if created during regular wear and tear or minor damage. • PUF foaming in case condensation due to leakage etc found. Scope of Work for Insulated Doors, Strip and Air curtains, Dock shelters: • Cleaning and oiling of rollers of doors • Gasket checking for leakage. Alignment of gasket if leakage is observed. • Replacement of gasket if gasket is damaged or found in improper condition. • P.V.C. strip Curtains: Replacement of PVC strips if any. • Air Curtains – check the overall condition. Replacement of blower/full unit, if required. • Dock shelter- check for any damage, leackage etc. appropriate action to be taken to so as to make them fully funcational. • Dock leveller: cleaning, lubricating the parts with proper lubracants, All necessary components are adjusted properly to make sure equipment works smoothly and consistently.check fluid level in hydraulic cylinders, top-up/ replace the fluid as may be necessary.

-

-

-

... More
Scope of work for Electrical System: • Transformer: oil condition checking, leakages to be attended, testing of oil for various parameters as per standard practice, Filtration or replacement / top up of oil as per condition of oil, Insulation resistance of the transformer should be checked, Bushings should be cleaned and inspected for any cracks, checking of any loose connections of the terminations of HV & LV side, breather examination. Dehydration of Silica gel if necessary. Explosion-vent diaphragm examination. Conservator to be cleaned from inside. Cleanliness in the Substation yard with all nets, vines, shrubs removed. • DG set: Routine & preventive maintenance of DG sets with AMF panels including maintenance of controlling/protective accessories, battery check. Replace/charge as required. DG set general servicing as per manufacturers recommendation. replacement of filters etc. as required. •HT / LT panels: Check for loose connection of all terminals in the panels, Clean gently the dust by air pressure in side the panels, Check the mounting of CTs for its position, ensure that does not make contact with body, Check for loose connections for all power / neutral cable connections, Check for all the fuses, Check for loose connections of all power cables & control cables of panel, Check for loose connections of cables of meters / contractors, Check the outgoing & incoming phase, neutral connection of circuit breaker, Check the thermal trip of circuit breaker, Check mountings of circuit breaker & tightness of power cables. If anything mentioned above found not normal, same shall be rectified • APFC panel: Cleaning should done by using blower. Microcontroller not working condition to be replaced. Current of each capacitor should be measured and recorded once in month to know healthiness of each capacitor bank. Current should be measured by using clamp tester. If the value of current is less than 50% of the rated value. Capacitor should be replaced with new one. Connections should be checked for any loose connections. • Routine, preventive maintenance of Lighting & Power Distribution Systems. • Routine, preventive maintenance of HT, LT cables & Wirings. • Earth resistance measurement of all the Earth electrodes • Checking, fitting cleaning and fault rectification of the lighting fixtures

-

-

-

... More
Scope of Work for Grading Sorting Line: • Motor - checking of alignment of motors • Bearing at various locations to be checked and oiled / greased wherever necessary • Lubrication to be carried out for all the rollers as necessary to avoid any squeaking noises. • Belt alignment • Pulley conditon checking • Heaters operation check and routine & preventive maintenance for dryer and hot water treatment units. • Washer Unit: water spray nozzels, brushes etc checking and routine maintenance. • Electronic weight sizer: routine & preventive maintenance. • Electrical control panel: routine & preventive maintenance. • Painting of parts wherever necessary to prevent parts from being rusted. Overall the grading sorting machineries are to be cleaned and made ready for use considering that they may be used for export oriented purpose. Parts that are coming in contact with the product during operation should be ensured to be of allowable SS or other food grade material. If any part like motor etc. needs replacement, then the cost of the motor / major part would be borne by the end-user / MSAMB / user but the installation and commissioning of the part shall have to be done as part of this contract and the labour costs and minor accessories for the same to be considered. For this, a site visit for seeing the condition of the equipment is extremely critical.

-

-

-

... More
Evaporative air cooling units: • Remove the filer pads and clean them thoroughly with a pressurized water jet • Water Sump cleaning • Water pump routine & preventive maintenance • Fan and Belts- check condition, preventive and routine maintenace • Air leaks in ducting and Water Leaks- check and attend if any • Electircal & contro System- checking, preventive and routine maintenace

-

-

-

... More
System for converting cold store to Precooling

-

-

-

... More
AIR COOLED CONDENSING UNITS For Pre-Cooling chamber 1,2 (General details as per PART – II - REFRIGERATION SYSTEM of GTS) Complete with Reputed approved make semi hermatic reciprocating compressor working on R449A / R448 A or other approved HFO, Air cooled condenser, Liquid receiver,Oil separator with check valve in discharge line, Base frame for mounting, H.P. / L.P.switches, Suction accumulator Vibration eliminator, Oil pr switch and pressure gauges , Sturdy MS Stand with two coats of primer and two coats of oil paint of approved colour etc. as required. Condenser coil to be designed for 10 deg C TD between ambient temperature and condensing temperature. Other Technical specifications as per General Technical specifications as mentioned in the tender. The capacity and other details shall be as follows : For Pre-Cooling chamber 1,2 ( 2 nos for each ACU): Capacity: 26 KW DesignTemperature: (-)4 deg. C evap. and +48 deg.C cond. Temp Maximum ambient Temperature: 42 deg C ambient Minimum fin spacing: 2 mm Condensing unit inlet air pre-cooling system: to be included There shall be provision to run each condensing unit separately especially in cases where product qty is low. Related controls (PLC if needed), cabling, control panel, etc shall be included in the cost. This shoud be possible in Automode as well as manual mode.

4

-

-

... More
AIR COOLING UNITS - Air Cooling Units for Pre-cooling chamber 1,2 (General details as per PART – II - REFRIGERATION SYSTEM of GTS) Technical specifications as per General Technical Specifications as mentioned in the tender. The capacity and other details shall be as follows : Make: Star coolers / GEA / Alfa Laval / Guentner / LU-VE / Thermofin / Eqvt, Model: To be Mentioned Type of Unit -Single / Twin: Twin coil type,Type of Refrigerant feed: HFO - DX Capacity - kW: 51, Evap. Temp. & TD ‘C’: (-)4 °C / 4 °C Coil / Fin MOC: Cu / Al, Fin spacing -mm: 6 mm Fin type: Plate, Finned coil length -m: To be Mentioned Total fan capacity of each unit– CMH: 52500, External sp. Wg, mm: 25 No of Fans/Unit: 3/4, Fan Motor -kW each: To be Mentioned Air throw -m: 8 m, Drain pan insulation: Required Drain pan heating: Not required Type of Defrosting: Electrical Fan peripheral heating: Not required Suitable Supporting structure from primary support at roof level or mounting stand (if supporting from floor level) to be considered in the costing as well. Product Covering Flap - Suitable product covering flap made of PVC sheet / EQVT sturdy material to be mounted on the unit above the fan(s) to ensure proper air flow through the produce. There shall be suitable reinforcement inside the flap as well as at the ends for supporting the Flap. Costing for the same also shall be included. It must be noted that this scheme is considered as a part of a combined pre-cooling system which will have an airtight plenum created between the wall panel and the area around the ACU as defined above. So while the insulated panel will be billed as per the the insulation panel rates, the cutting for the panel, the flashings, etc as needed for the pre-cooling unit arrangement should be considered while quoting the cost of panels.

2

-

-

... More
DISMANTLING OF EXISITNG EQUIPMENTS / ITEMS & THEIR RELOCATION: dismantling of exisitng Dock leveller, Dock door & dock shelter keeping protected the peripheral infrastructure against damage and re-installation,testing & commissioning of the same at the new dispatch dock location. Overhauling of these equipments and routine & preventive maintenance shall also be considedered in the costing.

2

-

-

... More
DISMANTLING OF EXISITNG EQUIPMENTS / ITEMS & THEIR RELOCATION: Dismantling of existing equiment/items keeping protected the peripheral infrastructure against damage & and re-installation,testing & commissioning of the same at the new location as instructed by client. 2 nos Air cooling units of cold rooms, their piping, cabling etc. Required additonal Refrigerant Cu piping running on cable trays, suction line insulation, UPVC drain piping, Controls,instruments (including Thermostatic expansion valves for each ACUs, Digital temperature indicator (0 to 50 deg. C range), Liquid line solenoid valves, DANFOSS / SPORLAN /EQVT make), painting,electrical power & control cabling, supporting structure for AC units etc as may be required to be considered in the costing. distance of new location of ACU is 30m from the condesing unit location

2

-

-

... More
Supply, Installation, Testing & Commissioning of New CT's & PT's inside 11 KV H.T. metering cubical (Compact Type) approved by MSEDCL/Licensee. all as per electricity board specifications and as per the revised load sanction, Job includes removal of old CT's & PT's and replacing it with new ones. All necessary accessories required for installation such as Cables, Clamps, Connectors, Lugs, Hardware, etc shall be included in Installation rate.

1

-

-

... More
Augmentation of 11 KV/0.433 KV, 200 KVA plinth transformer with 11 KV/0.433 KV, 315 KVA transformer. Job includes making necessary changes in foundation so as to install the new transformer. Supplying, installing, testing & commissioning 3 phase, 11/0.433 kV, 50 Hz., 315 kVA with OLTC (On Load Tap Changer), oil immersed and naturally cooled outdoor type, copper wound transformer, delta/star connected with additional neutral brought out on load side, temperature rise should not exceed 40oC by thermometer in oil and 45oC by the resistance in winding at full load rating, with HV tapping (with on load tap changer) on load +5 to -15 in steps of 2.5%, with standard accessories complete with test certificate with losses below 1025 Watts at 50% load, 3100 Watts at 100% load as per IS:1180 - 2014 energy efficiency level II, with necessary permissions of Electrical Inspector, Removal and take away existing 11 KV/0.433 KV, 200 KVA transformers. Dismantalling of Old HT Cable of 3C x 95 sqmm & LT Cable of 3.5C x 95 sqmm of old Transformer and reterminating above cables to new transformer or Panel. (200 KVA transformer price benifit should be passed on to Client)

1

-

-

... More
Export Facility Centre, Kalvan, Tal: Kalvan, Dist: Nashik

-

-

-

... More
PART A : Work Portion

-

-

-

... More
Civil Work

-

-

-

... More
Dressing of side shoulder / Scrapping the road side shoulder by Mechanical means ( By JCB /DOUZER) including excavation of raised side shoulders upto 15cm depth including remooving /cutting bushes,grass and dressing shoulder to desired camber and disposing of excavated stuff up to road boundary etc complete. ( S.S.R. 2021 -2022 , Page no. 59 Item no. 8.23, Additional Additional Specification :- - as directed by Engineer In Charge.)

1665

-

-

... More
Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5 m.) (S.S.R. 2021 -2022, Page no.115 Item no. 21.02, Additional Specification- Bd.A.1 Page No. 259)

323.56

-

-

... More
Excavation for foundation in hard murum including removing the excavated material upto distance of 50 metres beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.50 m) By Mechanical Means. (S.S.R. 2021 -2022,Page no.1115 Item no. 21.06,Additional Specification - Bd.A.2 Page No. 259)

222.29

-

-

... More
Excavation for foundation in Hard murum and boulders including removing the excavated material upto a distance of 50 metres, beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift from 1.5 m to 3.0 m.) (S.S.R. 2021 -2022,Page no.115 Item no. 21.10,Additional Specification- Bd.A.3 Page No. 259)

203.07

-

-

... More
Excavation for foundation in hard murum and boulders including removing the excavated material up to a distance 50 metres, beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5m.) By Mechanical Means. Spec.No. : Bd.A.3, Page No. 259. (S. S. R. I. No. 21.10 & P. No. 188)

9.86

-

-

... More
Excavation for foundation in Soft rock and old cement or lime masonry foundations including removing the excavated material upto a distance of 50 metres beyond the building area and stacking as directed, including dewatering, preparing the bed for the foundation and necessary back filling with available earth /murum, ramming, watering including shoring and strutting etc. complete (lift upto 1.5m) By Mechanical Means Spec.No. : Bd.A.4, Page No. 259.. (S. S. R. I. No. 21.14 & P. No. 188)

5.76

-

-

... More
Excavation for foundation in earth, soils of all types, sand, gravel and soft murum, including removing the excavated material upto a distance of 50 m. beyond the building area and stacking or spreading as directed, preparing the bed for the foundation and necessary back filling, ramming, watering, including shoring and strutting as necessary complete. (S.S.R.2021-22 Page no.-115 Item no.-21.04)

8.73

-

-

... More
Providing preconstructional antitermite treatment (S.S.R. 2021 -2022,Page no. 40 Item no 2-9-4 as per I.S. 6313 (Part-II) by treating the bottom surface and sides of excavation at the rate of 5 litres of emulsion concentrate of 1.0 percent of chlorophyrifos per square meter of surface area covering 10 years guarantee on bond paper. (S.S.R. 2021 -2022,Page no.116 Item no. 21.22,Additional Specification- As directed by Engineer in charge.)

252.41

-

-

... More
Providing preconstructional antitermite treatment (S.S.R. 2021 -2022,Page no. 40 Item no 2-9-4 as per I.S. 6313 (Part-II) by treating the top surface of plinth filling at the rate of 5 litres of emulsion concentrate at 1.0 percent of clorophyrifos per square metre of surface area covering ten years guarantee on bond paper . (S.S.R. 2021 -2022,Page no.117 Item no. 21.24,Additional Specification- As directed by Engineer in charge.)

1655.22

-

-

... More
Providing and laying Cast in situ/Ready Mix cement concrete in M-15 of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including bailing out water, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing if required and curing complete, with fully automaticn micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc complete. With natural sand/V.S.I. quality Artificial Sand . (S.S.R. 2021 -2022,Page no.131 Item no. 24.08,Additional Specification Bd.E.4 Page No.289 and B-7, pageno.38.)

311.91

-

-

... More
Providing and laying in situ/Ready Mix cement concrete M-25 of trap / granite /quartzite/ gneiss metal for R.C.C. work in foundations like raft, strip foundations, grillage and footings of R.C.C. columns and steel stanchions etc. including bailing out water, formwork, laying/pumping cover blocks, compaction and curing roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based PLC withnSCADA enabled reversible Drum Type mixer/ concrete Batchn mix plant (Pan mixer) etc. complete. With natural sand/V.S.I.quality Artificial Sand. (S.S.R. 2021 -2022,Page no.133 Item no. 25.11, Additional Specification- Bd.F.3 Page No. 298 and B.7, PageNo.38)

86.01

-

-

... More
Providing and laying Cast in situ/Ready Mix cement concrete M- 25 of trap / granite /quartzite/ gneiss metal for R.C.C. columns (S.S.R. 2021 -2022,Page no. 40 Item no 2-9-4 as per detailed designs and drawing or as directed including centering, formwork, cover blocks, laying/pumping,compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With natural sand/V.S.I. quality Artificial Sand . (S.S.R. 2021 -2022, Page no.134 Item no. 25.31,Additional Specification-Bd.F.5 Page No.300 and B.7,Page.No. 38)

76.03

-

-

... More
Providing and laying Cast in situ/Ready Mix cement concrete M- 25 of trap / granite /quartzite/ gneiss metal for R.C.C. beams and lintels (S.S.R. 2021 -2022,Page no. 40 Item no 2-9-4 as per detailed designs and drawings or as directed including centering, formwork, cover blocks, laying/pumping,compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With natural sand/V.S.I. quality Artificial Sand. (S.S.R. 2021 -2022,Page no.135 Item no. 25.50,Additional Specification- Bd.F.6 Page No. 300 and B.7, Page No.38)

121.19

-

-

... More
Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap/ granite/ quartzite/ gneiss metal for R.C.C. chajja / Canopy (S.S.R. 2021 -2022,Page no. 40 Item no 2-9-4 as per detailed design and drawings including steel centering, formwork, cover blocks compacting , curing , finishing and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc). (S.S.R. 2021 -2022,Page no.137 Item no. 26.05,Additional Specification- Bd.F.9 Page No. 303 and B.7, Page No.38)

8.14

-

-

... More
Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap/ granite/ quartzite/ gneiss metal for R.C.C. pardi of required thickness including steel centering, formwork, cover blocks, laying/pumping, ompacting , curing , finishing and rougheningthem if special finish is to be provided and curing complete.(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) . (S.S.R. 2021 -2022,Page no.137 Item no. 26.17, Additional Specification- Bd.F.11 Page No.304 and B.7, Page No. 38)

28.16

-

-

... More
Providing and laying Cast in situ/Ready Mix cement concrete in M-10 of trap / granite / quartzite / gneiss metal for foundation and bedding including bailing out water, Steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing if required and curing complete, with fully automatic micro processor based PLC with SCADA enabled reversibleDrum Type mixer/concrete Batch mix plant ( Pan mixer ) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) ) Spec. No. Bd. E. 1 Page No287 (S. S. R. I. No. 24.01 & P. No. 131)

18.98

-

-

... More
Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap/ granite / quartzite/ gneiss metal for R.C.C. slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks, compaction, finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete.(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete.With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) Spec. No. Bd.F.8 Page No. 302 and B.7, Page No.38 (S. S. R. I. No. 25.72 & P. No. 136)

16.76

-

-

... More
Providing and laying Cast in situ/Ready Mix cement concrete in M-15 of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including bailing out water, Steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing if required and curing complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand V (S.S.R.2021-22 Page no.-226 Item no.-24.04)

1.35

-

-

... More
Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations,slabs, beams columns, canopies, staircase, newels, chajjas,lintels pardis, copings, fins, arches etc. (S.S.R. 2021 -2022,Page no. 40 Item no 2-9-4 as per detailed designs,drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete. (S.S.R. 2021 -2022,Page no.139 Item no. 26.33,Additional Specification- Bd.F.17, Page No.306)

36.3

-

-

... More
Providing and fabricating structural steel work in rolled sections like joists, channels, angles, tees etc. (S.S.R. 2021 -2022,Page no. 40 Item no 2-9-4 as per detailed design and drawings or as directed including cutting, fabricating, hoisting, erecting, fixing in position making riveted / bolted /welded connections without connecting plates, braces etc. and including one coat of anticorrosive paint and over it two coats of oil painting of approved quality and shade etc. complete. (S.S.R. 2021 -2022, , Page no.129 Item no. 23.01,Additional Specification- Bd.C.2 Page No.275)

16.23

-

-

... More
Providing soling using 80 mm size trap metal in 15 cm. layer including filling voids with Crushed sand/grit, ramming, watering etc. complete. (S.S.R. 2021 -2022, Page no.118 Item no. 21.40,Additional Specification- As directed by Engineer in charge.)

428.99

-

-

... More
Filling in plinthe and floors with approved excavated material in 15cm to 20cm including watering and compacting etc. complete. (S.S.R. 2021 -2022,Page no.117 Item no. 21.36,Additional Specification- Bd.A.10 Page No.262)

594.17

-

-

... More
Filling in plinth and floors with contractors material/brought from outside and approved by Engineer incharge in layers of 15 cm to 20 cm including watering and compaction etc complete. (S.S.R. 2021 -2022,Page no.117 Item no. 21.37,Additional Specification- Bd.A.11 Page No.263)

731.72

-

-

... More
Conveying materials obtained from road cutting including all lifts, laying in layers of 20cm to 30cm. breaking clods, dressing to the required lines, curves, grades and section, watering and compacting to not less than 97% of standard Proctor density for a lead of over 50 m. to 300 m. inclusive from the site of excavation to the site of deposition as directed. (S.S.R. 2021 -2022,Page no.24 Item no. 2.25,Additional Specification- MORTH 305)

479.04

-

-

... More
Providing second class Burnt Brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in foundations and plinth of inner walls/ in plinth external walls including bailing out water manually , striking joints on unexposed faces, raking out joints on exposed faces and watering etc. Complete. (S.S.R. 2021 -2022,Page no. 144 Item no. 27.01,Additional Specification- Bd.G. 1 Page No.313)

11.13

-

-

... More
Providing second class Burnt Brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in superstructure including striking joints, raking out joints, watering and scaffolding etc. Complete. ( S.S.R. 2021 -2022, Page no. 144 Item no. 39.24,Additional Specification- Bd.G.5 Page No.315)

121.55

-

-

... More
Providing and fixing rolling shutter fabricated from steel laths of minimum thickness 0.9 mm with lock plate of 3.15 mm thickness reinforced with 35 x 35 x 5 mm angle section fitted with sliding bolts and handles for both sides, deep M.S. channel section of depth and thickness not less than 65 mm and 3.15 mm respectively with hold fast arrangements, M.S. Bracket plate 300 x 300 x 3.15 mm minimum size and shape with square bar, suspension shaft of minimum 32 mm diameter, hood cover of M.S. sheet not less than 0.9 mm thickness and of any size at top and safety devices including mechanical gear operation arrangement consisting of worm gear wheels and worms of high grade cast iron or mild steel and one coat of red lead primer etc complete. (I.S. 62481979) (Without mechanical gear. (S.S.R. 2021 -2022,Page no. 181 Item no. 27.05,Additional Specification- BD-T-55 Page No.510)

18

-

-

... More
Providing and fixing chicken mesh of 22 gauge, with about 30 cm.width at the junction of R.C.C members and brick work, of approved quality including fixing mesh in position by necessary drilling in concrete /B.B.masonry and or tying by binding wire etc. complete. (S.S.R. 2021 -2022,Page no. 154 Item no. 32.26,Additional Specification- As directed by Engineer in Charge)

556

-

-

... More
Providing internal cement plaster 12mm thick in single coat in cement mortar 1:4 with neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc complete. (S.S.R. 2021 -2022,Page no. 153 Item no 32.04,Additional Specification- Bd. L.2 Page No.368)

742.76

-

-

... More
Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 mm thick in cement mortar 1:4 using waterproofing compound at 1 kg per cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 mm thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc.complete. (S.S.R. 2021 -2022,Page no. 153 Item no 32.11,Additional Specification- Bd.L.7 Page No.369)

819.55

-

-

... More
Providing and fixing self supporting steel roofing system (Proflex) for a Godown or alike made up of structural grade steel sheet of 912 millimeter width ( tolerance + / - 2 millimeter ), moulded at site using mechanical press dies to the desired curve and shape to form 605 millimeter wide interlocking panels . The interlocking panels shall be pressed to close the seam forming water tight joints for a span of 21.30 meter having arch rise as 4.26 meter, arch length 25.13 meter.The base material made up of imported galvalume steel complying to ASTM A792 having base metal thickness of 1.00 millimeter ( tolerace + / - 0.02 millimeter ) with alloy coating AZ 150 and paint coating of regular modified polyster , top coat 25 micron and bottom coat 12 micron (S.S.R. 2021 -2022,Page no. 175 Item no 2-9-4 as per approved colour , including fixing hangers , clamps etc.as may be necessary of Proflex standard, including fixing sky light of 2 millimeter thick polycarbonate sheet of size 2' x 14' and turbo ventilator of 24'' diameter to be installed at every 30 feet along the length of roof including finishing , testing and cleaning etc. complete. (S.S.R. 2021 -2022,Page no. 299 Item no 38.42,Additional Specification- As directed by Engineer in charge.)

1208.7

-

-

... More
Providing and fixing colour coated Zinc alume (R) AZ150 (min 150 gms/sq.mt .total one ach side) profiled sheets for roofing. The feed materialis manufacture doutof nominal 0.45mm Base Metal Thickness (BMT) (0.5mmTCT),Hi-strength steel with min. 550M Payield strength, meta llichot dipcoated with Aluminium-Zincalloy (55% aluminium 43.4% zinc 1.6% silicon) with COLORBOND (R) steel quality super durable polyester paint coa (within organic pigment).The paint shall have a total coating thickness of nominal 35 um, comprising of nominal 25 umexterior coaton top surface and nominal 10 um reverse coaton back surface .Profilesheet shall have nom.950-1050mm effective cover width and nominal 25-30mm deep ribs with subtle square fluting in the five pan at nominal 180-250 mm center-to-center.The end rib shall be designed foranti-capillary groove.and returnleg.Thefeedmaterialshouldhavecoilmanufacturersproductdetailsmarkedaregularinterval.Includingfastenerswithmin.fastenedwithmin.25umZinc-Tinalloycoated,Hexhead,self-drillingscrewetc.complete.(weightofprofile4.52kg/sqm) (S.S.R. 2021 -2022,Page no. 173 Item no. 38.34 )

337.5

-

-

... More
Providing and applying washable oil-bound distemper of approved colour and shade to old and new surfaces in two coats including scaffolding, preparing the surfaces. (excluding the primer coat.) etc. complete. (S.S.R. 2021 -2022,Page no. 167 Item no. 36.11,Additional Specification- Bd.P.5 Page No.413)

308.61

-

-

... More
Providing and applying priming coat on concrete/ masonary/ Asbestos Cement plastered surfaces including scaffolding if necessary, preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter and sand papering as required etc. complete. (S.S.R. 2021 -2022, page no. 165 Item no. 35.21,Additional Specification- As directed by Engineer in charge.)

308.61

-

-

... More
Providing and applying two coats of exterior acraylic emulsion paint confirming to orresponding I.S. of approved manufacture and of approved colour to the plastered surfaces including cleaning ,preparing the plaster surface, applying primer coat ,scaffolding if necessary , and watering the surface for two days etc complete. (S.S.R. 2021 -2022,Page no. 165 Item no. 35.25,Additional Specification-As directed by Engineer in charge.)

680

-

-

... More
Providing and applying two coats of synthetic enamel paint of approved colour to new /old structural steel work and wood work in buildings, including scaffolding if necessary, cleaning and preparing the surface (excluding primer coat) etc. complete. (S.S.R. 2021 -2022,Page no. 164 Item no. 35.07,Additional Specification-Bd.O.5 Page No.405)

18

-

-

... More
Providing and fixing welded mesh of 11 gauge wires having mesh size 50 mm x 25 mm including M.S Angle frame of size 35 mm x 35 mm x5 mm in position with oil painting 3 coats etc. complete. ( S.S.R. 2021 -2022,page no. 190 Item no. 39.79,Additional SpecificationAs directed by Engineer in charge.)

18

-

-

... More
Providing and laying 125 micron Low Density Polyethylene (LDPE) sheet confirming to IS 3395 : 1997 below concrete pavement including all materials and labour complete. ( S.S.R. 2021 -2022,Page no. 37 Item no. 5.19,Additional SpecificationRD)

1911

-

-

... More
Providing and laying in situ cement concrete M-20 with tremix treatment for 100 mm thickness for flooring with groove cutting of 4 mm wide and 20 mm deep with necessary refilling with bitumen etc. complete. (S.S.R. 2021 -2022,Page no. 158 Item no. 33.30 ,Additional SpecificationAs directed by Engineer in charge)

1911

-

-

... More
Painting letters upto 20 cm height complete brushes, coir brushers, dusting, cleaning, including cost of paint etc. complete. ( S.S.R. 2021 -2022,page no. 39 Item no. 6.05, Additional SpecificationMORTH 801)

120

-

-

... More
Providing and fixing P.V.C. Rain water pipes of 110mm outer diameter and having wall thickness of 2.2 to 2.7 mm confirming to I.S. 13592 1992 including proper rainwater receiving recess with P.V.C. plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25mm to 40mm from face of wall a fixing with clips of approved quality and number ,filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on C.C. or masonry blocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All the P.V.C. fittings and additional 2 piece socket clips shall be got approved from engineer in charge etc. complete. (S.S.R. 2021 -2022,Page no. 207 Item no. 42.87, Additional SpecificationAs directed by Engineer Incharge.)

33

-

-

... More
Providing water proofing treatment (S.S.R. 2021 -2022,Page no. 40 Item no 2-9-4 as per IS : 1346-1966 to generally inaccessible sloping Reinforced Cement Concrete Terrace slab with bitumen felts in all positions in five course, consisting of applying cold bitumen primer coat at the rate of 2.5 litre per 10 Sqm., hot bitumen layer at the rate of 14.50 kg per 10 Sqm. and over the same layer of bitumen felt of type III grade (I) (S.S.R. 2021 -2022,Page no. 40 Item no 2-9-4 as per IS: 1332-1965 across the slope with 10 cm overlap commencing at lowest level and again applying hot bitumen course at the rate of 14.50 kg per 10 Sqm. and finally spreading over it grit at the rate of 14.50 kg per 10 Sqm. including all lifts, leads and scaffolding whenever necessary complete as directed with four years' guarantee on requisite stamp paper etc. complete. (S.S.R. 2021 -2022,Page no. 152 Item no31.17,Additional SpecificationAs directed by Engineer Incharge.)

117

-

-

... More
Dismantling brick masonry in lime or cement mortar and stacking the materils as directed with all leads, lifts etc. (S.S.R.2021-2022. Page no.-215 Item no.-46.09

20.03

-

-

... More
Removing doors and windows with frames and stacking the materials as directed with all leads, lifts etc. complete.(S.S.R.2021-2022. Page no.-215 Item no.-46.15)

4

-

-

... More
Dismantling the R.C.C. Work 1:2:4 and sorting out the materials such as steel etc. as directed and stacking them within the specified lead as directed etc. complete.(S.S.R.2021-2022. Page no.-216 Item no.-46.29)

128

-

-

... More
Removing cement tiles, or marble or polished shahabad floor or dado without bed concrete including stacking the materials as directed with all leads, lifts etc. complete (S.S.R.2021-2022. Page no.-216 Item no.-46.19)

256

-

-

... More
P/L cast in situ cement concrete M 20 for R.C.C.foundation (S.S.R.2021-2022. Page no.-132 Item no.-25.11)

51.2

-

-

... More
Disposing of dismantling materials of R.C.C. stone/ brick masonry / derbies, excavated material etc from work site beyond the 5 km Spec. No.:As directed by Engineer in charge etc. complete. (5km... )

125.23

-

-

... More
Providing fine cement finish 1.5 mm thick over green plaster surface including scaffolding curing etc. complete.Spec. As directed by Engineer in charge. (S. S. R. I. No. 32.21 & Page No. 154)

330

-

-

... More
Providing and constructing Brick Masonry Inspection Chamber 60cm x 45cm x 90cm including 1:4:8 cement concrete foundation 1:2:4 cement concrete channels half round G.S.W. pipes, Brick Masonry, plastering from inside and with frame fixed in cement concrete with R.C.C. Cover medium duty 140 kg with frame etc complete. Spec. No. Bd.V.43 Page No.574. (S. S. R. I. No. 42.17 & Page No. 201 )

8

-

-

... More
Providing and laying concrete pipes of I.S. NP. class of 150mm diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete.. Spec. No. Bd.V.41, Page No. 573 (S. S. R. I. No. 42.07 & Page No. 200)

24.2

-

-

... More
RWH - Shallow Percolation Pit providing, constructing 2.0m deep shallow depth percolation pit comprising of 1.0m dia pre-cast RCC rings, 300mm thick side filling around outside of RCC rings (annular space) with 40mm size boulders including filling of percolation pit up to 0.5m depth (from bottom up) with 25-75mm clean washed gravels followed by 0.5m depth of 10-25mm of clean washed stones followed by 0.5m of washed river fine aggregate (natural sand/crushed sand VSI grade finely washed etc.) including netlon mesh between each gravel/fine aggregate (natural sand/crushed sand VSI grade finely washed etc.) media layer including covering with RCC slab, manhole frame & cover, PVC rungs etc. including arrangement for inlet & outlet pipe, excavation & backfilling as shown in the drawing. The rate shall be inclusive of all labour, material, wastage, scaffolding, transportation, taxes, including all leads, lifts at all levels. All material should be of approved make. All works complete as per the drawing, technical specification and direction of the Engineer in charge (S. S. R. I. No. 48.46 & Page No. 229)

3

-

-

... More
Garden soils :- Supplying one side fresh garden soil well sieved 90% to pass through IS sieve of 10 mm size free from stone rubbish like dried grass root & other such materials the soil should be fresh from quarry. The colour of the soil generally be red. The soil will be measured by measuring box. (Item include Royalty charges. Corporation types transporting loading Unloading etc. complete. Horticulture DSR 1/2

3.75

-

-

... More
Suplying & laying well quality of manuar required for small, large tress including mixing with soil , watering, transportation at site etc. completed Horticulture DSR 2/2

3.75

-

-

... More
Saplings of flowering/shadytrces Gulmohar, Raintree, Peltophorum etc (one year old) Horticulture DSR 8/3

25

-

-

... More
Saplings of Small & medium Ornamental flowering plants , Thuja,Cupresus plants ornamental Ficus, Mussanda etc. Horticulture DSR 9/3

60

-

-

... More
Rose Plant :- Excavating pit with size 0.3x0.3x0.3 meter removing & conveying unwanted stuff of a required distance as directed filling the fresh garden soil in minor in 3:1 proportion to a required height of 0.3 meter mixing the soil & minor levelling, watering on previous night. Planting 40 to 50 cm height healthy plant of required rose verity mainaining till well established by watering weeding, sturring,prunning, replacing the casualities etc. complete. Horticulture DSR 9/5

20

-

-

... More
Mogra Plant/Creepers/Climbers:- Excavating pit with size 0.3x0.3x0.3 meter removing & conveying unwanted stuff of a required distance as directed filling the pit upto excavated material upto a height 15 cm. & ramming height of 15 cm. with fresh garden soil in minor in 3:1 proportion mixing the soil & minor levelling, watering on previous night. Planting (one year old) healthy plant as per specification mainaining till well established by watering weeding, sturring,prunning, replacing the casualities etc. complete. Horticulture DSR 10/6

20

-

-

... More
Planting large flowering/shady trees:- Digging pit with size 0.9 x 0.9 x 0.9 meter. Removing & conveying unwanted stuff of a required distance as directed filling the pit upto excavated material upto a height 30 cm. & ramming height of 60 cm. with fresh garden soil in minor in 3:1 proportion mixing the soil & minor levelling, watering on previous night. Planting (one year old) healthy trees sapling as per specification mainaining till well established by watering weeding, sturring of soil replacing of casualities etc. complete. Horticulture DSR 12/6

20

-

-

... More
Planting small & medium size ornamental flowering plant:-Digging pit with size 0.6 x 0.6 x 0.6 meter. Removing & conveying unwanted stuff of a required distance as directed filling the pit with fresh garden soil & farm yard minor upto a height of 0.6 meter in 3:1 proportion mixing the soil & minor levelling, watering on previous night. Planting (one year or two year old) healthy plant sapling as per specification mainaining till well established by watering, weeding, sturring of soil replacing of casualities etc. complete. Horticulture DSR 11/6

20

-

-

... More
Preparing instant Lawn :- Excavating the ground to a required depth of 20 cm. removing & conveying unwanted stuff to a required distance as directed filling fresh garden soil in minor in 3:1 proportion to a height of 20 cm. mixing soil & minor throughly well levelling with required slope light watering on previous night, rolling on surface. Fixed readymade lawn truf rolls or slab of reqired verity as directed. ramming on it for proper fixing & mainaining till well establish by watering, weeding, clipping or moving etc. complete. Horticulture DSR 3/4

6.25

-

-

... More
Preparing Edging or border:- Excavating the ground to a required depth of 20 cm. removing & conveying unwanted stuff to a required distance as directed filling fresh garden soil in minor in 3:1 proportion to a required height of 20 cm. mixing , levelling , watering the same planting suitable verity of edging plants & rooted cutting at distance of 15 cm. between plants to plants and row to row watering & maintaining till well grown to te stage of prunning Horticulture DSR 4/4

15

-

-

... More
Preparing Shrubbery:- Excavating the ground to a required depth of 30 cm. removing & conveying unwanted stuff to a required distance as directed. Providing and filling fresh garden required distance as directed. Providing and filling fresh garden soil and manure in excavated area in 3:1 proportion to a required height of 30 cm. Mixing , levelling , watering on previous night. Planting well rooted shrubs 0.5 mtrs. apart as directed and maintaining till well established by watering, weeding, strring replacing of casualties etc. complete. Horticulture DSR 8/5

7.5

-

-

... More
Dustbin 240 Litre Blue WB-240 Dimensions : 725 x 580 x 1075 mm ( 107x72x58cm ) Heavy Duty Sunproof Waste Garbage Bins Wheeled Bins Easy to maintain & Use Envirnoment Friendly Long Lasting Capacity : 240 Litre (Non SSR)

5

-

-

... More
Disposing of dismantling materials of R.C.C. stone/ brick masonry / derbies, excavated material etc from work site beyond the 5 km Spec. No.:As directed by Engineer in charge etc. complete. (Beed District D.S.R, Page No. 125, Sr. No. 486)

14.2

-

-

... More
Providing and applying washable oil bound distemper of approved colour and shade to old and new surfaces in two coats including scaffolding, preparing the surfaces (excluding the primer coat) complete.(S.S.R.2021-22 Page no.-1033 Item no.-36.11)

24.21

-

-

... More
Providing and applying two coats of exterior weather shield paint of approved manufacture and of approved colour to the plastered surfaces including cleaning ,preparing the plaster surface ,applying primer coat ,scaffolding if necessary, and watering the surface for two days etc complete. (S.S.R.2021-22 Page no.-1076 Item no.-35.26)

54.7

-

-

... More
Providing and fixing mild steel grill work for windows, ventilators, etc. 15 kg/sqm as per drawing including fixtures necessary welding and painting with one coat of anticorrosive paint and two coats of oil painting complete. (S.S.R.2021-22 Page no.- Item no.-40.02)

0.56

-

-

... More
Providing and fixing P.V.C. Rain water pipes of 110mm outer diameter and having wall thickness of 2.2 to 2.7 mm confirming to I.S. 13592-1992 including proper rainwater receiving recess with P.V.C. plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25mm to 40mm from face of wall a fixing with clips of approved quality and number ,filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on C.C. or masonry blocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All the P.V.C. fittings and additional 2 piece socket clips shall be got approved from engineer in charge etc. complete. (S.S.R.2021-22 Page no.- Item no.-42.87)

7

-

-

... More
Providing and fixing chicken mesh of 22 gauge, with about 30 cm. width at the junction of R.C.C members and brick work, of approved quality including fixing mesh in position by necessary drilling in concrete /B.B.masonry and or tying by binding wire etc. complete. (S.S.R.2018-19 Item No 32.26 additional spec no. As directed by Engineer in Charge: (S.S.R.2021-22 Page no.- Item no.-19.35)

25.41

-

-

... More
Providing waterproofing in W.C. and bath including brickbat coba in all position including providing and laying 12mm bedding in cement mortor 1:3 on vergin concrete slab with waterproofing compound @1kg/per bag of cement laying brickbat coba of required thickness in cm1:5with waterproofing compound1kg/bag of cement grouting and finishing the top layer with 20mm thick brick bedding in cm mortor 1:3 with waterproofing compound1kg/per bag of cement and testing the treated portion for 48 hours by pond test and covering ten years' guarantee on requisite stamppaper including curing etc. complete. (S.S.R.2021-22 Page no.- Item no.-31.26)

0.95

-

-

... More
Providing cement based waterproofing treatment to terraces(Indian waterproofing or alike)with brickbats laid in required slope to drain the water for any span after cleaning the base surface.Applying a coat of cement slurry admixed with approved waterproofing compound and laying the brickbats on bottom layer in C.M.1:5admixed with approved waterproofing compound filling upto half depth of brickbats,curing this layer for3days,applying cement slurry over this layer joint so fbrickbats with C.M.1:3 admixed with approvedwaterproofingcompoundandfinallytopfinishing with average 20mm.thick layers of same mortar added with jute fiber at 1Kg per bag including finishing the surface smooth with cement slurry admixed with approved waterproofing compound. Marking finished surface with false squares of 300mmx300mm. making the junctions at the parapet rounded and tapered top for required height,with drip mould at the junction of plaster and parapet and curing and covering 10 years Guarantee against leakproofness on Court fee stamppaper ofRs. 500/- including ponding test etc. complete.(S.S.R.2021-22 Page no.- Item no.-31.04)

8.82

-

-

... More
Providing and applying Two coats of wall care Putty on plastered surface and Ceiling and Walls to prepare surface even and smooth of approved make, etc complete.(S.S.R.2021-22 Page no.- Item no.-32.15)

13.68

-

-

... More
Providing and laying chequered tiles ofapproved qualityof size 30cmx30cm, confirming to corresponding I.S.forflooring in required position laid on a bed of1:4 cement mortar including cement float,filling joint with cement slurry cleaning curing etc. compl

8

-

-

... More
Providing and laying Antiskid Ceramic tile sof approved quality of size 30cmx30cma nd confirming toI S15622-2006(Group-BIIA) for antiskid flooring in required positionlaidonabedof1:4 cement mortar including cement float,filling joint with cement slurry cleaning curing etc. complete.

13.86

-

-

... More
Providing and laying vitrified mirror/glossy finish tile s having size 590mmto605mmx590mm to 605mm of 8to10mm thickness and confirming to IS.15622-2006 (groupBla) of approved make,shade and pattern fordadoandskirting inrequired position fixed in 1:4 cemen

22.37

-

-

... More
Providing and fixing in position powder coated aluminium louvered windows / ventilator of various sizes with powder coating as per detailed drawing and specifications including aluminium rames 80 x 38 mm x 1.22 mm box type, 5 mm thick sheet glass louvers, of approved quality etc. complete.(S.S.R.2021-22 Page no.-331 Item no.-39.68)

0.56

-

-

... More
Providing and fixing green marble of 18 to 20 mm thick for doorframe/ dado/ window boxing etc. On C.M. 1:6 including filling joints with polymer base filler nosing / moulding the sharp edges wherever necessary, curing, etc. complete.(S.S.R.2021-22 Page no.-280 Item no.-33.48)

1.86

-

-

... More
Providing and Fixing 30MM thick BOTH SIDE PRELAMINATED SOLID PANEL PVC DOOR SHUTTER consisting of frame made out of M.S tubes of 19 guage thickness and, size19x19mm for styles and15x15mm for the top and bottom rails, M.S frames hall have acoatofmetelprimer of approved make and manufacture. M.S frame shall be covered withheatmouledPVC'C'channelmadefrom 5mm (+/0.25)thick prelaminated sheet of density 600kg/cbm, ofsize30mm thickness 70mm widthout of which 50mm shall be flat and 20mm shall be tapered in 45? angle on either side for mingstiles;and 5mm thick,95 mm wide PVCsheet out of which 75mm shall be faltand 20mm shall be tapered in 45 on the inner side to form top and bottom railand 115mm wide PVC sheet out of which 75mm shall be faltand 20mm shall be tapered on both sides toform lockrail.Top, bottom and lockrailshall be provide deithersideofthepanel.Anadditional5mm(+/0.25)thickPVCstripof20mmwidthistobestuckonthebottomsideofthe'c'channelprelaminatedpanelingof5mm(+/0.25)thickPVCsheettobefittedinsidetheM.S.framewelded/sealedtothestylesandrailswith5mm(+/0.25)x30mmPVCsheetbeadingoneithersideandjoinedtogetherwithsolventcementadhesiveetc,10mmthickness(5mm(+/0.25)x2nos)20mmwidecrossPVCsheetasgapinsertfortherailandbottomrail.Doortobefixedtoframeswith3nosM.S.powdercoatedbuthingesofsize100mmx25MMx2mmusing32mmlongsteelscrewsdrilledsuitabletopassthroughboththewallsoftheM.Stube.Otherhardwaresshouldbefixedwith19x6mmsizesteelscrewsincludingfixturefasting.Complete as per direction of engineer in charge. (S.S.R.2021-22 Page no.- Item no.-40.04)

1.58

-

-

... More
Providing and fixing 450mmx550mm size superior type Belgium mirror with 16mm dia. nickel plated towel rod etc. complete.

1

-

-

... More
Providing and fixing 900mm high S.S.304 Grade Stainless steel railing with 40mm diameter and 1.5mm thick at top, 40mm diameter and 1.5mm thick vertical supports spacedat 1.5 mcenter to center and 8mm thick toughened glass including fabricating, fixtures, errecting, necessary welding, grinding ,finishing,buffing to stainless steelpipeetc. complete

18

-

-

... More
Providing and fixing coloured glazed earthenware wash hand basin of 63 cm x 45 cm Size including cold water pillar tap / cold and hot water pillar tap brackets, rubber plugs and brass chain, stop tap and necessary pipe connection including P.V.C. waste pipe and trap up to the outside face of the wall.. (S.S.R.2021-22 Page no.-369 Item no.-41.47)

1

-

-

... More
Providing and fixing C.P. pillar cock long neck with aerator of approed make including necessary sockets/union nut etc. complete. Spec. No. As Directed By Engineer In Charge.(S.S.R.2021-22 Page no.-316 Item no.-42.82)

1

-

-

... More
Providing and fixing C.P. Angular stop clock with wall flange of approved make continental including necessary sockets / union nut etc. complete. Spec. No. As Directed By Engineer In Charge. (S.S.R.2021-22 Page no.-361 Item no.-42.79)

1

-

-

... More
Providing and fixing C.P. BIB cock with wall flange of approved make including necessary sockets/ union nut etc. complete. Spec. No. As directed by Engineer in charge (S.S.R.2021-22 Page no.-361 Item no.-42.83)

1

-

-

... More
Providing and fixing H.D.P container Syntex or alike one piece moulded water tank made out of low density polythyler and built corrugation including of delivery upto destination hoisting and fixing of accessories such as inlet, outlet over flow of all tanks capacity above 1000 to 20,000 litres Spec. No. As directed by engineer incharge. (S.S.R.2021-22 Page no.-358 Item no.-42.54)

2000

-

-

... More
Providing and fixing on Walls / Ceiling / Floor 25 mm Dia. CPVC Pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Spec. No. BD.V 5 page 551 and as directed by Engineer in charge (S.S.R.2021-22 Page no.-359 Item no.-42.57)

4

-

-

... More
Providing and fixing on Walls / Ceiling / Floor 32 mm Dia. CPVC Pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Spec. No. BD.V 5 page 551 and as directed by Engineer in charge (S.S.R.2021-22 Page no.-359 Item no.-42.58)

2

-

-

... More
Providing and fixing on Walls / Ceiling / Floor 40 mm Dia. CPVC Pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Spec. No. BD.V 5 page 551 and as directed by Engineer in charge (S.S.R.2021-22 Page no.-359 Item no.-42.59)

2

-

-

... More
Providing and fixing on Walls / Ceiling / Floor 50 mm Dia. CPVC Pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Spec. No. BD.V 5 page 551 and as directed by Engineer in charge (S.S.R.2021-22 Page no.-359 Item no.-42.60)

8

-

-

... More
Providing and fixing on Walls / Ceiling / Floor 15 mm Dia. CPVC Pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Spec. No. BD.V 5 page 551 and as directed by Engineer in charge (S.S.R.2021-22 Page no.-358 Item no.-42.55)

15

-

-

... More
Providing and fixing 15 mm. dia Ball cock medium type with PVC float including sockets and necessary fittings and tested as per municipal requirements etc. complete. Spec. No. As Directed By Engineer In Charge. (S.S.R.2021-22 Page no.-355 Item no.-42.37)

15

-

-

... More
Providing and fixing 40 mm. dia Ball cock medium type with PVC float including sockets and necessary fittings and tested as per municipal requirements etc. complete. Spec. No. As Directed By Engineer In Charge. (S.S.R.2021-22 Page no.-355 Item no.-42.36)

1

-

-

... More
Providing and fixing European type wall-hung white water closet of approved make with push valve concealed type with cover plate 32mm size of approved make including soil pipe, vent pipe up to outside face of wall ,100mm dia. G.I. plug bend inlet pipe all fittings, cuttingand making good walls, floors etc. complete (S.S.R.2021-22 Page no.-362 Item no.-42.86)

1

-

-

... More
Providing and constructing Brick Masonry Inspection Chamber 90cm x 45cm x 90cm including 1:4:8 cement concrete foundation 1:2:4 cement concrete chanels half round G.S.W.pipes, Brick Masonry, plastering from inside and C.I. lid cover of 75 kg with lid and frame fixed in cement concrete (S.S.R.2021-22 Page no.-352 Item no.-42.11)

1

-

-

... More
Providing , laying and fixing ,jointing Eco- drain 200 mm SN 4 Nu-Drain Upvc pipes or of equivalent make, manufacture as per EN 13476 or equivalent as per I.S.15328 with fittings such a bends, tees tees, coupler etc, jointing with rubber lubricant including necessary excavation, trench refilling with selective excavated materialetc.complete.(S.S.R.2021-22 Page no.-371 Item no.-42.32)

10

-

-

... More
Covid-19 Health and safety: Providing and making necessary arrangements of various essential materials and items of recommended quality and make as per guidelines of the health department required for prevention of COVID-19 pandemic in consideration of health and safety management of man power at construction site 1. Hand Sanitizer.: 50 liters 2. Disinfectant. : 30 Liters 3. Sodium Hypochlorite. : 30 KG 4. Fogging machine and Liquid for sanitization.: 1 Number 5. 3 Ply Face Mask of good quality. : 500 Numbers 6. Surgical / Latex Gloves of good quality.: 200 Pairs 7. Rubber Gloves of good quality.: 100 Pairs 8. Empty Spray Bottles 100 ml (Plastic).: 20 Numbers 9. Empty Spray Bottles 1000 ml (Plastic).: 5 Numbers 10. PPE kits. : 10 Numbers 10. Temperature Guns. : 3 Numbers 11. Face shield : 30 Numbers

1

-

-

... More
Electromechanical work

-

-

-

... More
PART-1: Refrigeration P&M Works

-

-

-

... More
INSULATED PANEL Supply and Erection as per General Technical Specifications , for walls-80 mm thick PIR panels,Density: 40 ±2kg /m3 0.5 mm thick Precoated G.S. Sheet (min. 180 GSM) on both sides with polyester coating (thickness: 20~25 micron)

45

-

-

... More
INSULATED PANEL Supply and Erection as per General Technical Specifications , for walls-100 mm thick PIR panels,Density: 40 ±2kg /m3 0.5 mm thick Precoated G.S. Sheet (min. 180 GSM) on both sides with polyester coating (thickness: 20~25 micron)

481

-

-

... More
INSULATED PANEL Supply and Erection as per General Technical Specifications, for ceiling-60 mm thick PIR panels, Density: 40 ±2kg /m3 0.5 mm thick Precoated G.S. Sheet (min. 180 GSM) on both sides with polyester coating (thickness: 20~25 micron) Ceiling support system including supports for hanging/fixing ceiling structure from the roof/slab level to be included. This structure shall be ensured to be with complete thermal break and should avoid metal connection between inside and outside.

10

-

-

... More
INSULATED PANEL Supply and Erection as per General Technical Specifications, for ceiling-100 mm thick PIR panels, Density: 40 ±2kg /m3 , 0.5 mm thick Precoated G.S. Sheet (min. 180 GSM) on both sides with polyester coating (thickness: 20~25 micron) Ceiling support system including supports for hanging/fixing ceiling structure from the roof/slab level to be included. This structure shall be ensured to be with complete thermal break and should avoid metal connection between inside and outside. Additional PIR filled hat section of minimum 50 mm thicnkess beyond any metal member of the support should be considered if only metal 'T' is being considered for ceiling panel support.

260

-

-

... More
INSULATED FLOOR Supply and Erection as per General Technical Specifications Floor 100 mm XPS , min 30 kg/cu.m density. Rate for floor insulation to include supply and erection of all ancilliaries including polythene vapour barrier & two ply tarfelt as per specifications and bituminous primer, bitumin / bituminous cold compound for proper adhesion to surfaces.

255

-

-

... More
Supply & Fixing of 6~9 mm thick EPDM / Nitrile rubber on RCC slab / brick walls with suitable CPRX compound adhesive over which the insulated panels shall be fixed tightly with Nylon / FRP / Steel reinforced Nylon bolts.The bolt heads on the panels shall be covered with hat runners filled with PUF insulation as per standard practice.

85

-

-

... More
Supply & fixing of of Al foil min. 50 micron on RCC slab / brick walls with suitable CPRX compound adhesive / bitumen

90

-

-

... More
Ancillary Materials and Services - Flashings for Internal and external wall-ceiling joints and wall-wall joints as applicable or as may be required for doors or other openings. The layout showing the chamber dimensions and height is enclosed for ready reference. The flashings should be atleast 50mm x 50 mm or larger sizes with adequate overlap over any given panel-panel joint (Precoated G.S. Sheet, minimum 0.5 mm thick)

1

-

-

... More
Ancillary Materials and Services - Silicon / Polyeurathene sealant for sealing the gaps between panels and the external / internal face of the insulation panels and any other location as may be deemed suitable for proper insulation panel erection system as applicable.

1

-

-

... More
Ancillary Materials and Services - PUF/PIR chemical, adhesives,/ tapes / plastic caps etc reqd for onsite application, as may be necessary for a complete and foolproof insulation job.

1

-

-

... More
Ancillary Materials and Services -SITC of Pressure relief ports suitable for mounting on insulated panels of various thicknesses (60 mm to 100 mm) with internal heaters for room temperatures ranging from 25 deg C to (-) 10 deg C. (Fermond Soupape 2220 -Valve /Equivalent)- 1 no for each cold storage chamber.

4

-

-

... More
Ancillary Materials and Services - Making & finishing of cut outs for doors, pipes, cables, pressure ports etc as per requirement at site. Finishing would include filling with PUF/PIR & PUF/PIR foam of required density and covering with pre - coated G.I.sheet from both side of the panels to give aesthetically neat joint acceptable to Consultants / Owners. This should also include any additional Silicon sealent or any other material as required.

1

-

-

... More
Precooling Chamber1 Staging cold room 1,2 Manual Sliding type 1500 mm x 2600 mm ht x 100 mm thick PIR , manual type Providing & fixing of Insulated sliding doors (suitable for fitting on panel structure) of clear opening size & insulation thicknesses as mentioned and specifications as per General technical specifications (GTS). The doors shall be manual single leaf sliding with 0.6 mm thick SS-304 sheet or pre-coated extruded Aluminium of required thickness main frame. The door leaf shall have 0.5 mm thick PCGI sheet with min 180 GSM galvanising / S.S sheet cladding on both sides with PIR foam filled In-situ and with a density 40 ± 2 Kg/m3 (insulation thicknesses as mentioned).0.60mm thick PCGI sheet flashing to protect and reinforce the cut out opening in panel wall to be included in the cost. The sliding mechanism should be sturdy and smooth in operation complete with rail, runners, sill on the bottom etc. Rail shall be made of heavy duty aluminium alloy / SS with 45º drop & with polyethylene roller / special grade nylon arrangement runner system. The rail shall be provided with canopy / cover of 1.2 mm thick PCGI / Extruded Aluminium of required thickness. The doors shall have easily replaceable EPDM gaskets to ensure perfect hermetic sealing .

3

-

-

... More
SITC of strip curtains made of 3 mm thick transparent PVC sheet strips with 40 / 50 mm overlapping and supporting clamps. The strips shall have free swinging motion. The strip material shall be suitable for the specified low temperature application to ensure that it remains soft even at the lowest operating temperature

-

-

-

... More
Precooling Chamber 1, Staging cold room 1,2 Suitable for Clear opening Size: 1500mm X 2600mm ht

3

-

-

... More
Air Curtains for Pre-Cooling Chamber, staging cold room Supply & fixing of industrial type air curtains suitable for door clear opening size as mentioned and specifications given below. The Air Curtains shall incorporate centrifugal blowers made of SS / Aluminium with sealed ball bearings. The blowers shall be statistically and dynamically balanced. The motor shall be of standard make suitable for operation on single phase or three phase AC supply. The casing shall have a sturdy construction in SS304 finish. Adjustable louvers shall be provided for streamlining the air delivery.Air velocity to be in the range of 12 to 15 m/s. Proximity sensor with controller switch (limit switch) to be provided to ensure that the air curtain operates only when the door is open. Necessary fixing arrangement including sturdy brackets or base frame to bring the air curtain to the required level for proper air flow shall also be included in the cost. Necessary cabling in casing-capping / conduits as required by architects/owners from the switch points provided near the door shall also be included in the costing. Suitable for Clear opening size: 1500 mm x 2600 mm ht

3

-

-

... More
AIR COOLED CONDENSING UNITS For Pre-Cooling chamber 1,2 (General details as per PART – II - REFRIGERATION SYSTEM of GTS) Complete with Reputed approved make semi hermatic reciprocating compressor working on R449A / R448 A or other approved HFO, Air cooled condenser, Liquid receiver,Oil separator with check valve in discharge line, Base frame for mounting, H.P. / L.P.switches, Suction accumulator Vibration eliminator, Oil pr switch and pressure gauges , Sturdy MS Stand with two coats of primer and two coats of oil paint of approved colour etc. as required. Condenser coil to be designed for 10 deg C TD between ambient temperature and condensing temperature. Other Technical specifications as per General Technical specifications as mentioned in the tender. The capacity and other details shall be as follows : For Pre-Cooling chamber 1,2 ( 2 nos for each ACU): Capacity: 26 KW DesignTemperature: (-)4 deg. C evap. and +48 deg.C cond. Temp Maximum ambient Temperature: 42 deg C ambient Minimum fin spacing: 2 mm Condensing unit inlet air pre-cooling system: to be included There shall be provision to run each condensing unit separately especially in cases where product qty is low. Related controls (PLC if needed), cabling, control panel, etc shall be included in the cost. This shoud be possible in Automode as well as manual mode.

4

-

-

... More
AIR COOLED CONDENSING UNITS For staging cold room 1,2 (General details as per PART – II - REFRIGERATION SYSTEM of GTS) Complete with Reputed approved make semi hermatic reciprocating compressor working on R449A / R448 A or other approved HFO, Air cooled condenser, Liquid receiver,Oil separator with check valve in discharge line, Base frame for mounting, H.P. / L.P.switches, Suction accumulator Vibration eliminator, Oil pr switch and pressure gauges , Sturdy MS Stand with two coats of primer and two coats of oil paint of approved colour etc. as required. Condenser coil to be designed for 10 deg C TD between ambient temperature and condensing temperature. Other Technical specifications as per General Technical specifications as mentioned in the tender. The capacity and other details shall be as follows : For cold room 1 Capacity: 23.5 KW DesignTemperature: (-)4 deg. C evap. and +48 deg.C cond. Temp Maximum ambient Temperature: 42 deg C ambient Minimum fin spacing: 2 mm Condensing unit inlet air pre-cooling system: to be included

2

-

-

... More
AIR COOLING UNITS - Air Cooling Units for Pre-cooling chamber 1,2 (General details as per PART – II - REFRIGERATION SYSTEM of GTS) Technical specifications as per General Technical Specifications as mentioned in the tender. The capacity and other details shall be as follows : Make: Star coolers / GEA / Alfa Laval / Guentner / LU-VE / Thermofin / Eqvt, Model: To be Mentioned Type of Unit -Single / Twin: Twin coil type,Type of Refrigerant feed: HFO - DX Capacity - kW: 51, Evap. Temp. & TD ‘C’: (-)4 °C / 4 °C Coil / Fin MOC: Cu / Al, Fin spacing -mm: 6 mm Fin type: Plate, Finned coil length -m: To be Mentioned Total fan capacity of each unit– CMH: 52500, External sp. Wg, mm: 25 No of Fans/Unit: 3/4, Fan Motor -kW each: To be Mentioned Air throw -m: 8 m, Drain pan insulation: Required Drain pan heating: Not required Type of Defrosting: Electrical Fan peripheral heating: Not required Suitable Supporting structure from primary support at roof level or mounting stand (if supporting from floor level) to be considered in the costing as well. Product Covering Flap - Suitable product covering flap made of PVC sheet / EQVT sturdy material to be mounted on the unit above the fan(s) to ensure proper air flow through the produce. There shall be suitable reinforcement inside the flap as well as at the ends for supporting the Flap. Costing for the same also shall be included. It must be noted that this scheme is considered as a part of a combined pre-cooling system which will have an airtight plenum created between the wall panel and the area around the ACU as defined above. So while the insulated panel will be billed as per the the insulation panel rates, the cutting for the panel, the flashings, etc as needed for the pre-cooling unit arrangement should be considered while quoting the cost of panels.

2

-

-

... More
AIR COOLING UNITS - Air Cooling Units for Staging cold room 1,2 (General details as per PART – II - REFRIGERATION SYSTEM of GTS) Technical specifications as per General Technical Specifications as mentioned in the tender. The capacity and other details shall be as follows : Make: Star coolers / GEA / Alfa Laval / Guentner / LU-VE / Thermofin / Eqvt, Model: To be Mentioned Type of Unit -Single / Twin: Single coil type Type of Refrigerant feed: HFO - DX Capacity - kW: 23.5 Evap. Temp. & TD ‘C’: (-)4°C / 4 °C Coil / Fin MOC: Cu / Al Fin spacing -mm: 6 mm Fin type: Plate Finned coil length -m: To be Mentioned Total fan capacity of each unit– CMH: 27000 External sp. Wg, mm: 5 No of Fans/Unit: 2/3 Fan Motor -kW each: To be Mentioned Air throw -m: 9 m Drain pan insulation: Required Drain pan heating: Not required Type of Defrosting: Electrical Fan peripheral heating: Not required Suitable Supporting structure from primary support at roof level or mounting stand (if supporting from floor level) to be considered in the costing as well.

2

-

-

... More
Refrigeration Piping, Fittings & Valves (General details as per PART – II- REFRIGERATION SYSTEM of GTS) The piping shall be of refrigeration quality The piping shall be of refrigeration quality seamless copper tubes and the valves shall be brassomatic / Henry or equivalent make. The piping shall be included accessories such as filter, drier, sight glass, heat exchanger, suction lineaccumulator etc. as per P & I diagram approved by Consultant. Adequate number of supports shall be included. The piping shall be supported at distances of maximum 1.5 m from each other with suitably placed GS threaded rods of minimum 6 mm thickness when outside the chamber and piping shall be run on cable trays of size suitable to fit the pipes including insulation. Common cable trays can be considered depending on the suitability at site, however the same shall be acceptable to the consultant / owner. Overall, the piping execution shall ensure proper workmanship and a neat and tidy work is expected with straight horizontal and vertical lines and proper supporting. Under no circumstances shall any additional charges be demanded by the contractor for ensuring the same. The suction and discharge lines shall be designed for a maximum pressure drop corresponding to 1.1 deg. C drop in saturated evaporating and condensing temperatures. The liquid line shall be designed for maximum pressure drop corresponding to a drop 0.5 to 1 deg. C in saturation temperature. The piping shall be designed with proper slope in the direction of Refrigerant flow and to ensure proper oil return to the compressor and should be installed with adequate supports to avoid undue vibration. The piping should be thoroughly cleaned as per standard practice prior to installation. Refrigeration piping,fittings,valves,interconnecting condensing & evaporator unit complete with standard controls & accessories, supports as may be required shall be included in cost.layout drawing showing proposed location of condesing units is atttached for your reference.

1

-

-

... More
Suction line insulation (General details as per PART – II- REFRIGERATION SYSTEM of GTS) Suction line insulation with EPDM/ XLPE/Equivalent insulation with minimum 28G Aluminium foil Clading in the covered areas and Weatherproof Clading in areas exposed to sunlight and is uncovered ; e.g. Woven glass cloth with epoxy coating or Armacheck GC+weatherproof coating/equivalent Clading with suitable fittings and Adhesives.Alternatively,Fevicol Weather protect coat applied as per manufacturers recommendation may be used for entire insulton protection. Thickness - 25mm Insulation supports shall be half round or full round heavy duty PVC pipe sections of relevant size which shall be atleast 150 mm in length and shall be placed below every support. This is essentially ensuring that the insulation compression at the support is at the minimum.

1

-

-

... More
Drain piping with rigid U-PVC pipe from A.C. units to to suitable drain point complete with 'U' Traps for each cold room and supports.Drain lines (inside the chambers) to have 10 mm EPDM / Eqvt. insulation with factory backed Aluminium foil.Individiual Drain outlet line from ACU pipe size shall be same as the drain outlet of ACU and further the header shall be at least one size higher than the drain outlet connection size. Further, higher sizes may be considered as per the consultants/owner's recommendation

1

-

-

... More
Controls and Instruments (a) Thermostatic expansion valves for each ACUs (b) Digital temperature indicator cum controllers (0 to 50 deg. C range) (c) Liquid line solenoid valves, DANFOSS / SPORLAN /EQVT make (d) Digital temperature indicator (minus 20 to 50 deg. C range), for A.C. units to be placed outside the each cold rooms in ante-room area. (e) Digital RH indicator (0 to 100 % range) for A.C. units to be placed outside the each cold rooms in ante-room area. Only for pre-cooling ,cold room ACUs

1

-

-

... More
First charge refrigeration gas and oil etc. as required upto commissioning and final handling over of plant.

1

-

-

... More
Painting of equipment/piping / piping supports etc. as per standard colour codes with initial coat of red oxide primer and two coats of synthetic enamel paint .

1

-

-

... More
Humidification system for pre-cooling chambers complete with Industrial type Ultrasonic Humidifier, U-PVC water piping from the tanks to humidifier unit, fitting ,valves, atomizer nozzles (if requird), solenoid valves with strainers and humidistats etc. as may be required to maintain the relative humidity in the design range for Pre-Cooling Chambers. Also consider heavy duty PVC piping for air delivery into the cooling area for a release of humidified air into the main air stream, at atleast 1 m distance from the partition panel Humidifier Capacity: 12 Lit/hr.

2

-

-

... More
Electrical work for Refrigeration System (General details as per PART – II A- REFRIGERATION SYSTEM of GTS) Electrical control panel shall be manufactured as per specifications menioned in GTS and approved GA drawings. The Panel shall be comprising of following: a) Suitable Incomer of ACB / MCCB / MCB / RCBO of required rating and as per enclosed specification and approval. b) All Suitable rating MCB's, MPCB's, RCBO's, starters, relays, etc for various motors as used in the equipments shall be selected as per type 2 co ordination chart provided by the manufacturer. c) MCBs for control circuit d) Each starter shall be provided with facility for remote Start/Stop operation. Outgoing feeders for other equipments / items as give below also shall be provided. 10 A MPCB 4 pole suitable for protection of 3 HP motor x 1 nos 32 A 4 pole 10 KA MCB. - 2 NOS 32 A 2 pole 10 KA MCB. - 4 NOS for lighting system This panel shall be located in the plant room and shall have weather proof enclosure with suitable MCB's/RCCB's/RCBO's near the condensing unit. Job includes Electrical Power cabling (armoured) to all the outgoing feeders along with PVC medium duty Conduit/ pregalvanised Cable tray's, etc as per requirement and power cabling shall be as per specifications given in GTS. Control wiring with PVC insulated copper conductor with conduits as required for the refrigeration and other systems as defined here. Local Protection through MCB's/RCCB's/RCBO's for A.C. units, fan motors and other remotely located motors shall be part of the job.The Job shall also include earthing for control panel and various motors etc. using required sizes earthing conductors using GI/Cu earthing strips or Cu Conductors, all as per IS.The control panel shall have provision for interlocking of various equipment as per standard practice.

1

-

-

... More
Miscellaneous Items a) Vibration isolators for condensing units, supporting rods / Frame for A.C. Units with insulation, steel structure for mouting condensing units etc. as may be required b) Minor structural openings in walls / panels etc for piping, cabling etc. and finishing. c) 2000 lit water tank along with water pump as necessary for lifting water to the tank or lifting water from the tank depending on tank location ,UPVC piping, fittings,valves etc as may be required for condenser inlet air-precooling system. Condenser air pre-cooling system shall have automatic operation with water line sonenoid valves for each individual condensing unit and there shall be an interlock with the conensing unit start/stop as well as the ambiend air temperature wherein the air precooling system starts only after the ambient air temperature crosses 33 deg C and switches off when ambient goes beloe 33 deg C.

1

-

-

... More
Charges for Installation, Testing and Commissioning Installation, testing and commissioning of all above equipment / material as per the system requirement. All tools and tackles, welding machines, welding rods and gases etc. required for fabrication, erection, testing and commissioning shall be arranged by the contractor at his cost. The plant shall be erected, tested, commissioned as per Consultant's approved drawings / specifications and instructions to his and Employer's satisfaction. The refrigeration system shall be pressure tested and evacuated as per standard practice before charging the refrigerant. The water lines shall also be pressure tested as per standard practice. The plant shall be run for a period of three days after commoissioning by the contractor, to assess the plant performance. The contractor shall provide 3 hard copies of operation & maintenance for the plant along with as built drawings. The contractor shall also arrange the training of the operating staff for proper operation & maintenance of the plant (included in above rates)

1

-

-

... More
Part-2: Electrical work

-

-

-

... More
Supply, Installation, Testing & Commissioning of earthing station using pipe in pipe earthing electrode with complete system as per specs. Including boring, civil work, chamber etc. Earthing shall be carried out as described in IS-3043-1960 code. Pipe in pipe earthing electrode system shall be as per enclosed technical specifications. The entire earthing system should be executed as per system supplier’s instructions. The Earthing Chamber with all the necessary material required for earthing shall be in Contractors scope. Testing of the Earthing system shall be as per specification & results shall be submitted to Engineer-in-Charge duly signed by contractor and authorized representative. 2 meters Length Earthing Electrode

2

-

-

... More
Same as above but electrode length shall be 3 mts.

1

-

-

... More
Supply & Installation of 32 x 6 mm Galvanized Iron earthing strip & Conductor shall be of High Conductivity. All Necessary Accessories required for installation of Earthing Strips such as Porcelain Insulators, Clamps, Saddles, Hardware, etc will be included in the rate. The Earthing strips connections shall be used as per the provided earthing schedule.

50

-

-

... More
Same as above with Earthing strip of 25 x 3 mm Copper.

2

-

-

... More
Liaisoning Work with Electricity board & Electrical inspector or any other government authority for change of sanction & Contract load as per new requirement of electrical load. Job involves preparation of necessary documents with drawings, as required for load application, submission of document files with necessary officials / departments, follow-up with all concerned departments for getting required load sanctioned. Obtaining work completion report from Electrical inspector & board officials. Client (Owner) will make all official payments as per the requirement of Electricity board.

1

-

-

... More
Supply & Installation of printed Danger Board/instruction chart for treating persons suffering from electric shock, printed in English & Marathi and duly laminated complete.

2

-

-

... More
Providing Round bottom fire bucket of 9 Litres capacity as per IS : 2546 made out of 24 gauge G.I. sheet with extra handle at bottom duly painted white inside and red outside with FIRE Mark, on provided stand/ wall hook complete

6

-

-

... More
Providing Floor mounting stand for keeping 4 Nos. of FIRE buckets 1500mm in length, 900mm in height frame made out of 30x30x4 mm angle iron with cross supports for legs, welded with 4 hooks and duly painted with one coat of red lead and two coats of silver paint complete.

1

-

-

... More
Supplying and erecting wall hook 225mm projection for keeping fire buckets made out of 15 mm dia. M.S. Rod grouted in wall to a depth of minimum 15cms complete.

2

-

-

... More
Providing pair of duly tested rubber hand gloves as per IS :47705 suitable for working upto 22 kV supply complete.

1

-

-

... More
Supplying standard first aid box with necessary antiseptic cream, medicine for use on wounds due burn, crepe bandage, gauge bandage, medicated ready to use bandage (Band-Aid) adhesive tape for medicinal use, scissors, anti-septic solution, etc. (All above contents shall be of standard makes)

1

-

-

... More
Supplying and fixing PVC synthetic elastomer electrically insulating mat with class A insulation conforming to IS: 15652 – 2006 & CPRI tested having 2 mm thickness upto 3.3 kV

3

-

-

... More
Supplying and erecting D.C.P. type fire extinguisher 6 kg capacity cartridge type with gun metal cap 150 gram CO2 gas cartridge, powder and brackets conforming to IS 2171-1985/ IS 15683 and complete erected with necessary clamps made from 50x6 mm M.S. flat with nuts & bolts grouted in wall complete.

1

-

-

... More
Supplying and erecting ABC powder type fire extinguisher as per IS : 13849 /15683 of 6 kg capacity with necessary clamp for erection on wall.

1

-

-

... More
Supply, Installation, Testing & Commissioning of 3.5 C x 95 sq.mm, 1.1 KV grade, Stranded aluminium conductor, XLPE insulated, armoured, PVC outer sheathed cables conforming to IS:7098 ( Part-I ). The rates shall be inclusive of laying of cable in provided Trench/Pipe/Cable Tray. Termination of cables using double compression gland, crimping type lugs, etc. Each termination shall include supply of all necessary components, accessories, including double compression cable gland, cable lugs (crimping type) and consumables to make a complete termination in such a way that no live parts of the terminal and connecting lugs are exposed. While making termination, all other protection arrangement shall also be ensured. The cable tagging with proper ferrules shall be supplied & installed by the Contractor as part of cable termination work. Testing of the cables shall be as per specification & results shall be submitted to Engineer-in-Charge duly signed by contractor and authorized representative. Before Commissioning of cables Contractor need to check for physical damages & proper connection of all the terminals.

20

-

-

... More
Same as above but with 4.0 C x 6 sq. mm. Copper multi stranded.

10

-

-

... More
Same as above but with 4.0 C x 4 sq. mm. Copper multi stranded.

1

-

-

... More
Same as above but with 3.0 C x 6 sq. mm. Copper multi stranded.

1

-

-

... More
Same as above but with 3.0 C x 2.5 sq. mm. Copper multi stranded.

1

-

-

... More
Same as above but with 2.0 C x 2.5 sq. mm. Copper multi stranded.

1

-

-

... More
Supply, Installation, Testing & Commissioning of Primary light point wiring with 1.5 sq.mm. PVC insulated FRLS multistranded copper conductor wires, through PVC conduit concealed or surface mounted on ceiling/wall, point shall be controlled by 6 A modular type switch, with concealed/surface box, modular surface plate, ceiling rose/holder etc.

9

-

-

... More
Supply, Installation, Testing & Commissioning of Secondary light point wiring with 1.5 sq.mm. PVC insulated FRLS multistranded copper conductor wires, through PVC conduit concealed or surface mounted on ceiling/wall, point shall be controlled by 6 A modular type switch, with concealed/surface box, modular surface plate, ceiling rose/holder etc.

1

-

-

... More
Same as above but control shall be two way.

1

-

-

... More
Supply, Installation, Testing & Commissioning of fan point wiring with 1.5 sq.mm. PVC insulated copper conductor FRLS wires, through PVC conduit, concealed or surface mounted on ceiling/wall, point shall be controlled by 6 A modular type switch & step type electronic fan regulator with concealed/surface box, modular surface plate etc.

1

-

-

... More
Same as above but on lighting switch board ( Half Pt.).

3

-

-

... More
Supply, Installation, Testing & Commissioning of 6 Amp. socket point wiring with 2x1.5+1x1.0 sq.mm.PVC insulated copper conductor FRLS wires, through PVC conduit, concealed or surface mounted on the ceiling/wall, with modular type 6 Amp. switch & 5 pin socket, concealed/surface box, modular surface plate etc.

1

-

-

... More
Supply, Installation, Testing & Commissioning of 6 A sockets with modular type switches, concealed/surface box, modular surface plate etc., without any wiring & conduit ( wiring & conduit will be measured in mains ).

1

-

-

... More
Supply, Installation, Testing & Commissioning of 6/16 A socket point wiring with 2x2.5+1x1.5 sq.mm.PVC insulated copper conductor FRLS wires, through PVC conduit, concealed/surface mounted on the ceiling/wall, with modular type 16 Amp. switch & 6/16 A socket, concealed/surface box, modular surface plate etc.

1

-

-

... More
Supply, Installation, Testing & Commissioning of 6/16 A socket point with modular type switches, concealed/surface box, modular surface plate etc., without any wiring & conduit (wiring & conduit will be measured in mains ).

4

-

-

... More
Supply & Installation of 25mm medium duty PVC conduit with standard accessories and to be used for concealed / surface mounted on the ceiling/wall.

100

-

-

... More
Same as above but with 32 mm

1

-

-

... More
Supply & Installation of 25 mm wire reinforced type flexible PVC conduit with PVC glands on both sides to be used for flexible copper wires / cables.

5

-

-

... More
Same as above but with 32 mm

1

-

-

... More
Supply, Installation, Testing & Commissioning of mains / sub-main wiring using FRLS type wires of 2x2.5 sq.mm. + 1x1.5 sq.mm. PVC insulated, multistranded copper conductor through existing PVC conduit. ( Measurement of conduit & wires shall be separate ).

100

-

-

... More
Same as above but with 2x4.0 sq.mm. + 1x2.5 sq.mm.

1

-

-

... More
Same as above but with 6.0 sq.mm

30

-

-

... More
Same as above but with 4.0 sq.mm

1

-

-

... More
Same as above but with 2.5 sq.mm

1

-

-

... More
Supply, installation, testing & commissioning of 8 way SPN MCB DB with double door, comprising of following: Incoming : 25 A DP RCBO 30 mA Hpi type. 1 No. Outgoing : 10 A 1 pole 10 KA MCB. 4 Nos.

1

-

-

... More
Supply, Installation, Testing & Commissioning of 6 to 32 A DP MCB with MS box.

1

-

-

... More
Supply, Installation, Testing & Commissioning of IP 65, PVC Junction box with 2way connectors & earthing terminal inside.

2

-

-

... More
Supply, Installation, Testing & Commissioning of 39/40 Watt LED Capsule type IP 65 protection, suitable for surface mounting. System Efficacy 90, Colour Temp 6500K, CRI Value minimum 80, Operating Temperature is 0 Deg. Driver having voltage range of 120 - 300 Volts, THD less than 10%, P.F. greater than 0.95, surge protection =2.5 KV, inbuilt over voltage & under voltage protection. Complete with mounting bracket suitable for Surface mounting, wiring etc.

1

-

-

... More
Supply, Installation, Testing & Commissioning of 20 Watt LED Capsule type IP 65 protection, suitable for surface mounting. System Efficacy 90, Colour Temp 6500K, CRI Value minimum 80, Operating Temperature is 0 Deg. Driver having voltage range of 120 - 300 Volts, THD less than 10%, P.F. greater than 0.95, surge protection =2.5 KV, inbuilt over voltage & under voltage protection. Complete with mounting bracket suitable for Surface mounting, wiring etc.

9

-

-

... More
Supply, Installation, Testing & Commissioning of 225 mm sweep fresh air cum exhaust fan with bird screen.- cfm for ventilation fans is 425 (±10%)

1

-

-

... More
Supply, Installation, Testing & Commissioning of 375/380 mm sweep heavy duty exhaust fan with bird screen.- cfm for ventilation fans is 1470 (±10%)

1

-

-

... More
Supply, Installation, Testing & Commissioning of 450 mm sweep heavy duty exhaust fan with bird screen.- cfm for ventilation fans is 2650 (±10%)

1

-

-

... More
Supply, Installation, Testing & Commissioning of audio, visual alarm system for cold storage rooms. Job involves solid state Annunciator with hooter & enclosure,along with 30 min power back up, installed in occupied area, stay-put type push button station in each cold rooms / pre cooling rooms, cabling from cold rooms / pre cooling rooms to Annunciator. Job involves following items. 4 points Annunciator - 1 No Stay-put type push buttons. - 2 Nos. 2Cx0.75 sq. mm.Copper Flexible multi stranded cable. - 50 Mtrs Medium duty PVC conduit of 25 mm size with standard accessories. - 50 Mtrs

1

-

-

... More
PART-3: Grading sorting Equipments

-

-

-

... More
SITC of 3 LAYER CONVEYOR SYSTEM for grapes with Top belt for punnet, middle boxes conveyor & bottom empty crates conveyor. estimated length:25 m Acceptable make: Locus systems / Kailash Engg. / Fruit technologies / eqvt apporved The conveyor shall be complete with Side Member [“C” Channel] Is In M.S. [4mm Thick Sheet] , S.S. 304 [1.2 Mm Thick] Conveyor Top Plate [Below The Belt], Belt Thcknes Is - 3 Mm [Food Grade] 500 Mm Width Make- Ntb /eqvt approved, Motor & Gear Box Are Bonfigulily / eqvt approved make (1hp), All M.S Material used shall be CNC Punching & Bending & shall be Powder Coated. VFD Or Drive to be Provided For Conveyor Speed [Delta / eqvt approved Make] Bottom Pvc Rollers For Belt Support – 2 Rollers Per 2mtr [Dia 45 X 550 Mm] Conveyor Drum, H/W & Its Mouting Brackets to be Plated. 20 Single Sockets Point For Weighing Scale & Its Wiring [with Fire Proof Cables]

1

-

-

... More
SITC of PVC ROLLER CONVEYOR FOR CRATES estimated length: 20m, Acceptable make: Locus systems / Kailash Engg. / Fruit technologies / eqvt apporved Side Member [“C” Angle] Is In S.S. [2mm Thick Sheet] All Ms Material shall be with Punching & Bending & powder coated PVC Pipe with 4 mm Thickness Make Dutron / eqvt apporved Pictch Between Two Roller to be 150 mm Roller Size: 45 Mm X 500 Mm Internal MS Plated Shaft :12 Mm Dia Conveyor H/W : MS Plated 304

2

-

-

... More
SITC of LABLE APPLICATOR, Acceptable make: Locus systems / eqvt apporved Dispensing speed 230 sticker/min. [depends upon label size] Label height upto 4 inch All head components are made in S.S 304 & stand is made in MS pipe structured. The unit shall have Low maintenance. 4 inch HMI for User Friendliness shall be provided. Automatic speed synchronization by integration using Rotary Encoder.

1

-

-

... More
PART-4: Miscellaneous Items

-

-

-

... More
Pallets Dimensions: 1000mm X 1200mm X 150 mm approx. ht Colour: as approved by client Pallet type: four side fork opening Weight carrying capacity: 1500 Kg Suitable to use with all kind of material handling equipments including hand pallet trucks etc. Working Temperature range: (-) 25 deg C to (+) 10 deg C heavy duty type, Top Deck : Perforated MOC Shall be food grade plastic/HDPE and shall have excellent impact strength and high compression resistance.

100

-

-

... More
Hydraulically Operated Hand Pallet Truck Type : Hydraulically operated Hand Pallet Truck Load Capacity in kgs: 1500 kg Fork Length in mm (Suitable for liifting pallet of size of 1000 mm X1200 mm X154 mm ) Wheel MOC : Nylon / Polyurethane Suitable for heavy duty operation and long life,

2

-

-

... More
WEIGHING TABLES (1800mm x 600mm x 800mm ht) SS top plate 1.5 mm thick [SS304] MS square pipe size 32 x 32 mm x 2mm All fabricated structure shall be powder coated & level pads shall be provided

20

-

-

... More
Overhauling of Machineries for 1 precooling chamber, 4 cold rooms ,ante-room , transformer, DG sets, HT/LT/APFC panels and other electrical system, dock,grading sorting line and overall any activity not mentioned but needed to carry out utilizing the equipment in effective manner. It is recommended that bidder shall visit the site and get the idea of quantom of work before quoting.

1

-

-

... More
The details of the exisiting machinery is as follows, • PRE-COOLING CHAMBER:1 no, CDU (2 nos), Air Handling Unit 43 kW capacity, water pump: 1 x 3 Kw, 1 no • Cold Storage 1,2,3,4: CDU: air cooled condensing unit 1 no for each room., Air Cooling Unit: 13.5 KW each unit • Ante-room: Air cooled condesing nuit and indoor unit 1 nos • Evaporative air cooling units: Qty-2 nos • Air curtains, QTY: 13 Nos. • Grading Sorting Lines • Transformer: 200 KVA • DG set: 200 KVA • 11 KV Outdoor type MCCB panel • Main PCC panel • APFC panel:microcontroller based. • Lighting fixtures: internal as well as external street lighting of different wattage

-

-

-

... More
Scope of Work for Refrigeration System: • Checking of operational log readings recorded by operators during the previous month.& Discussion operational problems, if any, with maintenance/operation staff. • Checking the actual performance of the machines and Checking & correcting the set parameters, if required. • Carrying out minor repairs. Replace minor parts ,if required. • Making recommendations to client for smooth & trouble free operation of the machines. • Cleaning & combing of ACU’s fins, suction filters, driers, pump ,strainers etc. •ACU fan & motor- routine & preventive maintenance • To check oil level in the compressor, if less then oil to be charged in to the compressor. • Check liquid sight glass to determine the shortage of refrigerant if any / to check moisture contained in the system. Top up if required. • Inspect system for visible signs of leaks. If found, attend the leaks. If any brazing work involved should be carried out by the contractor at his cost • Inspect & adjust, if required, all safety controls. • carrying out calibration of gauges, temperature , RH sensors etc, wherever caliberation time frame has exceeded • Inspect the condition of refrigerant and drain pipe insulation (drain pipe insulation wherever applicable).To be replaced if found not in good condition. • Condenser inlet air pre-cooling system - to be cleaned, pump repaired (if required), pipig cleaned and other routine and preventive maintenance.

-

-

-

... More
Scope of Work for Insulated Sandwich Panels: • Insulated Panel Structure: Filling of silicon sealant as & where required to stop air leakages if any. • Floor Insulation – checking for gaps created between civil floor and wall insulation and sealing the same with silicon sealant / PUF filling depending on the size of the gap, if created during regular wear and tear or minor damage. • PUF foaming in case condensation due to leakage etc found. Scope of Work for Insulated Doors, Strip and Air curtains, Dock shelters: • Cleaning and oiling of rollers of doors • Gasket checking for leakage. Alignment of gasket if leakage is observed. • Replacement of gasket if gasket is damaged or found in improper condition. • P.V.C. strip Curtains: Replacement of PVC strips if any. • Air Curtains – check the overall condition. Replacement of blower/full unit, if required. • Dock shelter- check for any damage, leackage etc. appropriate action to be taken to so as to make them fully funcational. • Dock leveller: cleaning, lubricating the parts with proper lubracants, All necessary components are adjusted properly to make sure equipment works smoothly and consistently.check fluid level in hydraulic cylinders, top-up/ replace the fluid as may be necessary.

-

-

-

... More
Scope of work for Electrical System: • Transformer: oil condition checking, leakages to be attended, testing of oil for various parameters as per standard practice, Filtration or replacement / top up of oil as per condition of oil, Insulation resistance of the transformer should be checked, Bushings should be cleaned and inspected for any cracks, checking of any loose connections of the terminations of HV & LV side, breather examination. Dehydration of Silica gel if necessary. Explosion-vent diaphragm examination. Conservator to be cleaned from inside. Cleanliness in the Substation yard with all nets, vines, shrubs removed. • DG set: Routine & preventive maintenance of DG sets with AMF panels including maintenance of controlling/protective accessories, battery check. Replace/charge as required. DG set general servicing as per manufacturers recommendation. replacement of filters etc. as required. •HT / LT panels: Check for loose connection of all terminals in the panels, Clean gently the dust by air pressure in side the panels, Check the mounting of CTs for its position, ensure that does not make contact with body, Check for loose connections for all power / neutral cable connections, Check for all the fuses, Check for loose connections of all power cables & control cables of panel, Check for loose connections of cables of meters / contractors, Check the outgoing & incoming phase, neutral connection of circuit breaker, Check the thermal trip of circuit breaker, Check mountings of circuit breaker & tightness of power cables. If anything mentioned above found not normal, same shall be rectified • APFC panel: Cleaning should done by using blower. Microcontroller not working condition to be replaced. Current of each capacitor should be measured and recorded once in month to know healthiness of each capacitor bank. Current should be measured by using clamp tester. If the value of current is less than 50% of the rated value. Capacitor should be replaced with new one. Connections should be checked for any loose connections. • Routine, preventive maintenance of Lighting & Power Distribution Systems. • Routine, preventive maintenance of HT, LT cables & Wirings. • Earth resistance measurement of all the Earth electrodes • Checking, fitting cleaning and fault rectification of the lighting fixtures

-

-

-

... More
Scope of Work for Grading Sorting Line: • Motor - checking of alignment of motors • Bearing at various locations to be checked and oiled / greased wherever necessary • Lubrication to be carried out for all the rollers as necessary to avoid any squeaking noises. • Belt alignment • Pulley conditon checking • Heaters operation check and routine & preventive maintenance for dryer and hot water treatment units. • Washer Unit: water spray nozzels, brushes etc checking and routine maintenance. • Electronic weight sizer: routine & preventive maintenance. • Electrical control panel: routine & preventive maintenance. • Painting of parts wherever necessary to prevent parts from being rusted. Overall the grading sorting machineries are to be cleaned and made ready for use considering that they may be used for export oriented purpose. Parts that are coming in contact with the product during operation should be ensured to be of allowable SS or other food grade material. If any part like motor etc. needs replacement, then the cost of the motor / major part would be borne by the end-user / MSAMB / user but the installation and commissioning of the part shall have to be done as part of this contract and the labour costs and minor accessories for the same to be considered. For this, a site visit for seeing the condition of the equipment is extremely critical.

-

-

-

... More
Evaporative air cooling units: • Remove the filer pads and clean them thoroughly with a pressurized water jet • Water Sump cleaning • Water pump routine & preventive maintenance • Fan and Belts- check condition, preventive and routine maintenace • Air leaks in ducting and Water Leaks- check and attend if any • Electircal & contro System- checking, preventive and routine maintenace

-

-

-

... More
Export Facility Centre, Chandwad , Tal: Chandwad , Dist: Nashik

-

-

-

... More
PART A : Work Portion

-

-

-

... More
Civil Work

-

-

-

... More
Dressing of side shoulder / Scrapping the road side shoulder by Mechanical means ( By JCB /DOUZER) including excavation of raised side shoulders upto 15cm depth including remooving /cutting bushes,grass and dressing shoulder to desired camber and disposing of excavated stuff up to road boundary etc complete. ( S.S.R. 2021 - 2022 , Page no. 59 Item no. 8.23, Additional Additional Specification :- - as directed by Engineer In Charge.)

322.93

-

-

... More
Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5 m.) (S.S.R. 2021 - 2022, Page no.115 Item no. 21.02, Additional Specification- Bd.A.1 Page No. 259)

266.19

-

-

... More
Excavation for foundation in hard murum including removing the excavated material upto distance of 50 metres beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.50 m) By Mechanical Means. (S.S.R. 2021 - 2022,Page no.115 Item no. 21.06,Additional Specification - Bd.A.2 Page No. 259)

189.78

-

-

... More
Excavation for foundation in Hard murum and boulders including removing the excavated material upto a distance of 50 metres, beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift from 1.5 m to 3.0 m.) (S.S.R. 2021 - 2022,Page no.149 Item no. 21.10,Additional Specification- Bd.A.3 Page No. 259)

178.8

-

-

... More
Excavation for foundation in earth, soils of all types, sand, gravel and soft murum, including removing the excavated material upto a distance of 50 m. beyond the building area and stacking or spreading as directed, preparing the bed for the foundation and necessary back filling, ramming, watering, including shoring and strutting as necessary complete. (SSR 201-22 Item No. 21.04 Page No. 115)

8.73

-

-

... More
Excavation for foundation in hard murum including removing the excavated material upto distance of 50 meteRs. beyond the building area and stacking or spreading as directed, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete.(SSR 201-22 Item No. 21.12 Page No. 116)

6.48

-

-

... More
Excavation for foundation in Soft rock and old cement or lime masonry foundations including removing the excavated material upto a distance of 50 metres beyond the building area and stacking as directed, including dewatering, preparing the bed for the foundation and necessary back filling with available earth /murum, ramming, watering including shoring and strutting etc. complete (lift upto 1.5m) By Mechanical Means Spec.No. : Bd.A.4, Page No. 259.. (S. S. R. I. No. 21.14 & P. No. 188)

6.76

-

-

... More
Providing preconstructional antitermite treatment (S.S.R. 2021 - 2022,Page no. 40 Item no 2-9-4 as per I.S. 6313 (Part-II) by treating the bottom surface and sides of excavation at the rate of 5 litres of emulsion concentrate of 1.0 percent of chlorophyrifos per square meter of surface area covering 10 years guarantee on bond paper. (S.S.R. 2021 - 2022,Page no.116 Item no. 21.22,Additional Specification- As directed by Engineer in charge.)

376.63

-

-

... More
Providing preconstructional antitermite treatment (S.S.R. 2021 - 2022,Page no. 40 Item no 2-9-4 as per I.S. 6313 (Part-II) by treating the top surface of plinth filling at the rate of 5 litres of emulsion concentrate at 1.0 percent of clorophyrifos per square metre of surface area covering ten years guarantee on bond paper . (S.S.R. 2021 - 2022,Page no.117 Item no. 21.24,Additional Specification- As directed by Engineer in charge.)

319.4

-

-

... More
Providing and laying Cast in situ/Ready Mix cement concrete in M-10 of trap / granite / quartzite / gneiss metal for foundation and bedding including bailing out water, Steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing if required and curing complete, with fully automatic micro processor based PLC with SCADA enabled reversibleDrum Type mixer/concrete Batch mix plant ( Pan mixer ) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) ) (S. S. R. I. No. 24.01 & P. No. 131)

18.98

-

-

... More
Providing and laying Cast in situ/Ready Mix cement concrete in M-15 of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including bailing out water, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing if required and curing complete, with fully automaticn micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc complete. With natural sand/V.S.I. quality Artificial Sand . (S.S.R. 2021 - 2022,Page no.131 Item no. 24.08,Additional Specification Bd.E.4 Page No.289 and B-7, pageno.38.)

17.82

-

-

... More
Providing and laying in situ/Ready Mix cement concrete M-20 of trap / granite /quartzite/ gneiss metal for R.C.C. work in foundations like raft, strip foundations, grillage and footings of R.C.C. columns and steel stanchions etc. including bailing out water, formwork, laying/pumping cover blocks, compaction and curing roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based PLC withnSCADA enabled reversible Drum Type mixer/ concrete Batchn mix plant (Pan mixer) etc. complete. With natural sand/V.S.I.quality Artificial Sand. (S.S.R. 2021 - 2022,Page no.133 Item no. 25.11, Additional Specification- Bd.F.3 Page No. 298 and B.7, PageNo.38)

90.33

-

-

... More
Providing and laying Cast in situ/Ready Mix cement concrete M- 20 of trap / granite /quartzite/ gneiss metal for R.C.C. columns (S.S.R. 2021 - 2022,Page no. 40 Item no 2-9-4 as per detailed designs and drawing or as directed including centering, formwork, cover blocks, laying/pumping,compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With natural sand/V.S.I. quality Artificial Sand . (S.S.R. 2021 - 2022, Page no.134 Item no. 25.31,Additional Specification-Bd.F.5 Page No.300 and B.7,Page.No. 38)

56.73

-

-

... More
Providing and laying Cast in situ/Ready Mix cement concrete M- 20 of trap / granite /quartzite/ gneiss metal for R.C.C. beams and lintels (S.S.R. 2021 - 2022,Page no. 40 Item no 2-9-4 as per detailed designs and drawings or as directed including centering, formwork, cover blocks, laying/pumping,compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With natural sand/V.S.I. quality Artificial Sand. (S.S.R. 2021 - 2022,Page no.135 Item no. 25.50,Additional Specification- Bd.F.6 Page No. 300 and B.7, Page No.38)

66.31

-

-

... More
Providing and laying Cast in situ/Ready Mix cement concrete M-20 of trap/ granite/ quartzite/ gneiss metal for R.C.C. chajja / Canopy (S.S.R. 2021 - 2022,Page no. 40 Item no 2-9-4 as per detailed design and drawings including steel centering, formwork, cover blocks compacting , curing , finishing and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc). (S.S.R. 2021 - 2022,Page no.137 Item no. 26.05,Additional Specification- Bd.F.9 Page No. 303 and B.7, Page No.38)

9.24

-

-

... More
Providing and laying Cast in situ/Ready Mix cement concrete in M-20 of trap/ granite/ quartzite/ gneiss metal for R.C.C. pardi of required thickness including steel centering, formwork, cover blocks, laying/pumping, ompacting , curing , finishing and rougheningthem if special finish is to be provided and curing complete.(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) . (S.S.R. 2021 - 2022,Page no.137 Item no. 26.17, Additional Specification- Bd.F.11 Page No.304 and B.7, Page No. 38)

4.78

-

-

... More
Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap / granite /quartzite/ gneiss metal for R.C.C. work in foundations like raft, strip foundations, grillage and footings of R.C.C. columns and steel stanchions etc. including bailing out water, Steel centering, formwork ,cover blocks, laying/pumping, compaction and curing roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc). Spec. No. Bd. F.3 Page No. 298 and B.7, Page No. 38 (S. S. R. I. No. 25.13 & P. No. 133)

31.48

-

-

... More
Providing and casting in situ cement concrete of M25 of trap / granite /quartzite/ gneiss metal for R.C.C. columns as per detailed design and drawings or as directed, including steel centering, plywood/steel formwork, compaction, finishing uneven and honeycombed surface with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing etc. complete. Including use of plastisizer wherever necessary as directed by Engineer (Excluding reinforcement, including cover block). The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed)(SSR 201-22 Item No.25.33 Page No. 230)

0.8

-

-

... More
Providing and casting in situ cement concrete of M25 grade of trap / granite /quartzite /gneiss metal for R.C.C. beams and lintels as per detailed design and drawings or as directed,including steel centering, plywood/steel formwork steel props, compaction, finishing uneven and honeycombed surface with C.M.1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete. Including use of plastisizer wherever necessary as directed by Engineer-In-charge (Excluding reinforcement, including cover block). The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed) (SSR 201-22 Item No.25.52 Page No.235 )

4.5

-

-

... More
Providing and casting in situ cement concrete of M25 of trap / granite /quartzite /gneiss metal for R.C.C Chajja as per detailed design and drawings including steel centering, plywood /steel formwork, steel props, compaction, finishing uneven and honeycombed surface with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided with fan hook box of 2 mm thick M.S.Sheet rectangular size 180 mm x 100 mm with required depth, with holes or notches, as required, bottom and top lids of 1.6 mm thick M.S.Sheet (SSR 201-22 Item No. 26.07 Page No. 782)

0.04

-

-

... More
Providing and laying Cast in situ/ReadyMix cement concrete in M-25 of trap/granite/quartzite/gneiss metal for R.C.C. pardi of required thickness including steel centering, formwork, cover blocks, laying/pumping, compacting and roughening them if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel). with fully automatic microprocessor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand/Crushed sand VSI Grade finely washed etc) Spec. No. Bd.F.11 Page No. 304 and B.7, Page No. 38 (S. S. R. I. No. 26.19 & P. No. 137)

37.2

-

-

... More
Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap/ granite / quartzite/ gneiss metal for R.C.C. slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks, compaction, finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete.(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete.With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) Spec. No. Bd.F.8 Page No. 302 and B.7, Page No.38 (S. S. R. I. No. 25.72 & P. No. 227)

24.19

-

-

... More
Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations,slabs, beams columns, canopies, staircase, newels, chajjas,lintels pardis, copings, fins, arches etc. (S.S.R. 2021 - 2022,Page no. 40 Item no 2-9-4 as per detailed designs,drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete. (S.S.R. 2021 - 2022,Page no.139 Item no. 26.33,Additional Specification- Bd.F.17, Page No.306)

32.75

-

-

... More
Providing and fabricating structural steel work in rolled sections like joists, channels, angles, tees etc. (S.S.R. 2021 - 2022,Page no. 40 Item no 2-9-4 as per detailed design and drawings or as directed including cutting, fabricating, hoisting, erecting, fixing in position making riveted / bolted /welded connections without connecting plates, braces etc. and including one coat of anticorrosive paint and over it two coats of oil painting of approved quality and shade etc. complete. (S.S.R. 2021 - 2022, , Page no.129 Item no. 23.01,Additional Specification- Bd.C.2 Page No.275)

0.67

-

-

... More
Providing soling using 80 mm size trap metal in 15 cm. layer including filling voids with Crushed sand/grit, ramming, watering etc. complete. (S.S.R. 2021 - 2022, Page no.118 Item no. 21.40,Additional Specification- As directed by Engineer in charge.)

104.18

-

-

... More
Filling in plinthe and floors with approved excavated material in 15cm to 20cm including watering and compacting etc. complete. (S.S.R. 2021 - 2022,Page no.117 Item no. 21.36,Additional Specification- Bd.A.10 Page No.262)

409.61

-

-

... More
Filling in plinth and floors with contractors material/brought from outside and approved by Engineer incharge in layers of 15 cm to 20 cm including watering and compaction etc complete. (S.S.R. 2021 - 2022,Page no.117 Item no. 21.37,Additional Specification- Bd.A.11 Page No.263)

153.47

-

-

... More
Conveying materials obtained from road cutting including all lifts, laying in layers of 20cm to 30cm. breaking clods, dressing to the required lines, curves, grades and section, watering and compacting to not less than 97% of standard Proctor density for a lead of over 50 m. to 300 m. inclusive from the site of excavation to the site of deposition as directed. (S.S.R. 2021 - 2022,Page no.24 Item no. 2.25,Additional Specification- MORTH 305)

82.37

-

-

... More
Providing second class Burnt Brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in foundations and plinth of inner walls/ in plinth external walls including bailing out water manually , striking joints on unexposed faces, raking out joints on exposed faces and watering etc. Complete. (S.S.R. 2021 - 2022,Page no. 144 Item no. 27.01,Additional Specification- Bd.G. 1 Page No.313)

11.19

-

-

... More
Providing second class Burnt Brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in superstructure including striking joints, raking out joints, watering and scaffolding etc. Complete. ( S.S.R. 2021 - 2022, Page no. 144 Item no. 39.24,Additional Specification- Bd.G.5 Page No.315)

184.38

-

-

... More
Providing and fixing rolling shutter fabricated from steel laths of minimum thickness 0.9 mm with lock plate of 3.15 mm thickness reinforced with 35 x 35 x 5 mm angle section fitted with sliding bolts and handles for both sides, deep M.S. channel section of depth and thickness not less than 65 mm and 3.15 mm respectively with hold fast arrangements, M.S. Bracket plate 300 x 300 x 3.15 mm minimum size and shape with square bar, suspension shaft of minimum 32 mm diameter, hood cover of M.S. sheet not less than 0.9 mm thickness and of any size at top and safety devices including mechanical gear operation arrangement consisting of worm gear wheels and worms of high grade cast iron or mild steel and one coat of red lead primer etc complete. (I.S. 62481979) (Without mechanical gear. (S.S.R. 2021 - 2022,Page no. 181 Item no. 27.05,Additional Specification- BD-T-55 Page No.510)

18

-

-

... More
Providing and fixing chicken mesh of 22 gauge, with about 30 cm.width at the junction of R.C.C members and brick work, of approved quality including fixing mesh in position by necessary drilling in concrete /B.B.masonry and or tying by binding wire etc. complete. (S.S.R. 2021 - 2022,Page no. 154 Item no. 32.26,Additional Specification- As directed by Engineer in Charge)

341.66

-

-

... More
Providing internal cement plaster 12mm thick in single coat in cement mortar 1:4 with neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc complete. (S.S.R. 2021 - 2022,Page no. 153 Item no 32.04,Additional Specification- Bd. L.2 Page No.368)

1482.89

-

-

... More
Providing fine cement finish 1.5 mm thick over green plaster surface including scaffolding curing etc. complete.Spec. As directed by Engineer in charge. (S. S. R. I. No. 32.21 & Page No. 154)

330

-

-

... More
Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 mm thick in cement mortar 1:4 using waterproofing compound at 1 kg per cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 mm thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc.complete. (S.S.R. 2021 - 2022,Page no. 153 Item no 32.11,Additional Specification- Bd.L.7 Page No.369)

1329.91

-

-

... More
Providing and fixing self supporting steel roofing system (Proflex) for a Godown or alike made up of structural grade steel sheet of 912 millimeter width ( tolerance + / - 2 millimeter ), moulded at site using mechanical press dies to the desired curve and shape to form 605 millimeter wide interlocking panels . The interlocking panels shall be pressed to close the seam forming water tight joints for a span of 21.30 meter having arch rise as 4.26 meter, arch length 25.13 meter.The base material made up of imported galvalume steel complying to ASTM A792 having base metal thickness of 1.00 millimeter ( tolerace + / - 0.02 millimeter ) with alloy coating AZ 150 and paint coating of regular modified polyster , top coat 25 micron and bottom coat 12 micron (S.S.R. 2021 - 2022,Page no. 307 Item no 2-9-4 as per approved colour , including fixing hangers , clamps etc.as may be necessary of Proflex standard, including fixing sky light of 2 millimeter thick polycarbonate sheet of size 2' x 14' and turbo ventilator of 24'' diameter to be installed at every 30 feet along the length of roof including finishing , testing and cleaning etc. complete. (S.S.R. 2021 - 2022,Page no. 175 Item no 38.42,Additional Specification- As directed by Engineer in charge.)

967.84

-

-

... More
Providing and applying washable oil-bound distemper of approved colour and shade to old and new surfaces in two coats including scaffolding, preparing the surfaces. (excluding the primer coat.) etc. complete. (S.S.R. 2021 - 2022,Page no. 167 Item no. 36.11,Additional Specification- Bd.P.5 Page No.413)

1072.95

-

-

... More
Providing and applying priming coat on concrete/ masonary/ Asbestos Cement plastered surfaces including scaffolding if necessary, preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter and sand papering as required etc. complete. (S.S.R. 2021 - 2022, page no. 165 Item no. 35.21,Additional Specification- As directed by Engineer in charge.)

1048.74

-

-

... More
Providing and applying two coats of exterior acraylic emulsion paint confirming to orresponding I.S. of approved manufacture and of approved colour to the plastered surfaces including cleaning ,preparing the plaster surface, applying primer coat ,scaffolding if necessary , and watering the surface for two days etc complete. (S.S.R. 2021 - 2022,Page no. 165 Item no. 35.25,Additional Specification-As directed by Engineer in charge.)

1190.37

-

-

... More
Providing and applying two coats of exterior weather shield paint of approved manufacture and of approved colour to the plastered surfaces including cleaning ,preparing the plaster surface ,applying primer coat ,scaffolding if necessary, and watering the surface for two days etc complete. (SSR 201-22 Item No. 35.26 Page No. 1076)

54.7

-

-

... More
Providing and applying two coats of synthetic enamel paint of approved colour to new /old structural steel work and wood work in buildings, including scaffolding if necessary, cleaning and preparing the surface (excluding primer coat) etc. complete. (S.S.R. 2021 - 2022,Page no. 164 Item no. 35.07,Additional Specification-Bd.O.5 Page No.405)

18

-

-

... More
Providing and fixing welded mesh of 11 gauge wires having mesh size 50 mm x 25 mm including M.S Angle frame of size 35 mm x 35 mm x5 mm in position with oil painting 3 coats etc. complete. ( S.S.R. 2021 - 2022,page no. 190 Item no. 39.79,Additional SpecificationAs directed by Engineer in charge.)

18

-

-

... More
Painting letters upto 20 cm height complete brushes, coir brushers, dusting, cleaning, including cost of paint etc. complete. ( S.S.R. 2021 - 2022,page no. 39 Item no. 6.05, Additional SpecificationMORTH 801)

120

-

-

... More
Providing and fixing P.V.C. Rain water pipes of 110mm outer diameter and having wall thickness of 2.2 to 2.7 mm confirming to I.S. 13592 1992 including proper rainwater receiving recess with P.V.C. plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25mm to 40mm from face of wall a fixing with clips of approved quality and number ,filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on C.C. or masonry blocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All the P.V.C. fittings and additional 2 piece socket clips shall be got approved from engineer in charge etc. complete. (S.S.R. 2021 - 2022,Page no. 207 Item no. 42.87, Additional SpecificationAs directed by Engineer Incharge.)

33.5

-

-

... More
Providing water proofing treatment (S.S.R. 2021 - 2022,Page no. 40 Item no 2-9-4 as per IS : 1346-1966 to generally inaccessible sloping Reinforced Cement Concrete Terrace slab with bitumen felts in all positions in five course, consisting of applying cold bitumen primer coat at the rate of 2.5 litre per 10 Sqm., hot bitumen layer at the rate of 14.50 kg per 10 Sqm. and over the same layer of bitumen felt of type III grade (I) (S.S.R. 2021 - 2022,Page no. 40 Item no 2-9-4 as per IS: 1332-1965 across the slope with 10 cm overlap commencing at lowest level and again applying hot bitumen course at the rate of 14.50 kg per 10 Sqm. and finally spreading over it grit at the rate of 14.50 kg per 10 Sqm. including all lifts, leads and scaffolding whenever necessary complete as directed with four years' guarantee on requisite stamp paper etc. complete. (S.S.R. 2021 - 2022,Page no. 152 Item no31.17,Additional SpecificationAs directed by Engineer Incharge.)

133.42

-

-

... More
Providing and fixing in position,Double shuttered aluminium extruded powder coated openable door of specified size with aluminium doorframe of powder coated section101.60x44.75m,3.18mmthik and shutter comprising of powder coated section having bottom and lock railofsize150mmx44.5mmx3.00mmthicktoprails47.62x44.45mmx.00mmthick,verticalstyle47.62x44.45mm,3.00mmthickandforshutterplainglasspanes5mmthickfortoppanelsand12mmthickbothsidelaminatedphenolbondedparticleboardpanelsforbottopanelsetc.,I.S.I.mark,heavyduty,Hydraulicfloorspringof150kgcapacity,havingheavydutyconcealedlock,necessarybeading,glazingclips,PVCgaskets,250mmlengthaluminiumtowerbolts,150mmdia.padhandle,etc.asperdetaileddesignanddrawingorasdirectedbyengineerinchargeincludingallmaterials,labours,and equipment etc.complete

27.45

-

-

... More
Providing and fixing factory made solid core flush door shutters in double leaves 35mm thick,decorative type of exterior grade, as per detailed drawings, conforming to I.S.: 2202 – 1966 (Revised) including approved face veneers on both sides, without glazing and venetians including mat finish stainless steel fixtures and fastening, stoppers and finishing with french polishing etc. (Excluding door frame)(Sample to be got approved from Ex. Engineer before use) Commercial Hard Wood shutter

7.2

-

-

... More
Providing and fixing in position (as per 1868 / 1982) Aluminium sliding window of three tracks with rectangular pipe 95 x 38.10 x 0.90 mm at weight 0.637 kg/Rmt. with window frame bottom track section 92 x 31.75 x 1.30 mm at weight 1.070 kg/Rmt.. Top and side track section 92 x 31.75 x 1.30 mm at weight 0.933 kg/Rmt. The shutter should be of bearing bottom 40 x 18 x 1.25 mm at weight 0.417 kg/Rmt. Inter locking section 40 x 18 x 1.10 mm at weight 0.469 kg/Rmt. and handle and top section 40 x 18 x 1.25 mm at weight o.417 kg/Rmt. As per detailed drawings and as directed by Engineerincharge with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 mm thick plain glass and aluminium mosquito net shutter with stainless steel jail with all required screws and nuts etc, complete. With powder coating with box

4.5

-

-

... More
Providngandfixinginpositionanodisedextrudedaluminumpartitions,partlyglazedandpartlylaminatedhavingframemadeoutofextrudedtubularsectionofsize40mmx60mmwith12mmthickthreelayeredflatpressedteakwoodparticleboardbondedwithBWPtypeexteriorgradephenolformaldehydesyntheticresinconformingtoIS128231990,laminatedonbothsides,Novateakorequivalentand5mmthickselectedqualityplain/floatglasspanelsfixedwithaluminumglassclips12mmx12mmandrubbercushioningbeadingto glass partitions as per approved drawing etc. compete

89.76

-

-

... More
Medium Height Partition @ 1800/1200HTTILEBASEDPARTITIONSYSTEM:-TilebasedAluminumpartitionsystemof1800/1200mmht.madeof60mmthkaluminumframeshavingtwoseparateracewaysforlayingelectrical&computerwiring.Thewiremanagementshallbethroughtotheracewaytobefittedatbottomofpartitionandotherimmediatelybelowofworktopwithhookontyperacewaycoverforeasyaccessofwires.FramestobejoinedbyaluminumconnectorswithM6x16pan-headmachinscrewandwasherwithaluminumpostcover.Postcoverofsnaponfashiontobeconnectedonaluminumconnectors.Allvisiblealuminiumtobeinanodizedfinish.Thetop/exposedsidesoftheframeandpostsshouldbecoveredwithhorizontal/VerticaltrimandcapsmadeofAluminuminanodizedfinishinordertoenhanceitslook.UppertilesofpartitiontobeinSoftBoardorMarkertileof9mm.thk.,andprelaminatedparticalboardlowertilesinlaminatefinishof9mm.thk.on both the sides.

18

-

-

... More
Multiple Compartment Lockers @ 1140Lx 457D x 1830 mm. Ht.Providing and fixing Multiple Compartment Lockers @1140Lx457Dx1830mm. Ht.with12 Compartments ,Completebody & shutter made of CRCA Sheet with powder coated finish as per approved color.

2

-

-

... More
Inspection kit

1

-

-

... More
Providing & Fixing of TABLE @ 1800Lx900Dx 750HT:- TOP to be made of 25 mm thick Prelaminated particle board with PVC edge band, GABLE END to be made of 25 mm thick Prelaminated particle board with PVC edge band,MODESTY PANEL to be made of 25 mm thick Prelaminated particle board with PVC edge band, Access FLAP (1NOS.)

4

-

-

... More
Providing &Arrangemnt of MIdBack,Normal Syncro Mechanism,FixedArmrest,Gas lift for Seat height adjustment,Standard5-prong/Nylon Base with Leather Upholstery

8

-

-

... More
Foot operated sink units with sope dispensor single person use Size: 400x380x845mm + 2% Material: SS 304 Bowl Shape: Round Feature: Without Faucet No. of holes: One Thkness: Minimum 1.0 mm Splash Back Height: 45 mm + 10% Surface Treatment: Brushed Sink Style: Single Bowl Finish: Mirror Polished

2

-

-

... More
Hand Sanitizer Dispensor (Automatic/Hands Free) -Easy touchless operation with on and off button -Chrome and black with clear liquid chamber that stores up to 16.5 ounces of liquid content including soap or hand sanitizer -Amount of liquid dispensed can be adjusted -Touchless dispenser should sit on the countertop or mount to the wall -AA batteries operated for operating touchless dispenser

4

-

-

... More
Hand dryer -Material: ABS Plastic -Power: 2200 watts -Water Splash Proof: IP X 1 -Voltage: 220 V -Frequency: 50Hz-60Hz -Air Speed: 16M/S -7-12s fast drying hands

3

-

-

... More
Supplying standard first aid box with necessary antiseptic cream, medicine for use on wounds due burn, crepe bandage, gauge bandage, medicated ready to use bandage (Band-aid) adhesive tape for medicinal use, scissors, anti-septic solution (Savlon or similar) etc. (All above contents shall be of standard makes). 10-2-27

2

-

-

... More
Providing printed instruction chart

15

-

-

... More
Provided pair of duly tested rubber hand gloves as per IS :340715 suitable for working on 22kV supply. 10-2-23

4

-

-

... More
Inspection Tables with tubelights - M.O.C.: S.S. 304 - Length X Width: 1.2m X 0.76m x 0.76m - Support Str.: S.S. 304 -Thickness: minimum 2 mm; -Buffing: Mirror Finish - LED Tubelight 22 W to be fitted with SS structure -No. of legs: 6 made of 30 x 30 x 1.6 mm square tubes with rubber packing.

2

-

-

... More
Laboratory Equipments for pack house: A. EQUIPMENTS 1. Illuminated magnifier (Magnoscope) 20 X 2No* (Indian make) 2. Stereo binocular microscope with cold light source with 3MP camera 1No (Indian Make) 3. Inspection Table clear white top (steel make 2.5’X6’) 2 No* 4. Desktop Computer with internet 1No 5. Printer (24 Pin dot matrix) 1No 6. UPS for computer with sufficient power back up 1No B. INSPECTION KIT 1. Kit bag 1No.; 2. Knife (pointed) 2 No.; 3. Magnifier glass- 20 X with provision of light 2No.; 4. Camel brush 2No.; 5. Scissor 2No.; B146+B15. Torch with cell 2No.; 7. Forceps 2No.; 8. Marker pen- (Red & Black) 2No.; 9. Pencil &Sharpener 2No.; 10. Stapler With pin 1No.; 11. Cello tape- 1No.; 12. Rexene sheet- 1No.; 13. Marking slip- 50 No.; 14. Specimen vials - 20 No.; 15. Poly bags- 20No.; 16. Needle- 1No.; 17. Calculator- 1No.; 18. Hand Gloves- 30 pairs; 19. White enameled Tray (solid type) 4 Nos; 20. Apron 30 No.

1

-

-

... More
Weigh Balance (digital), 150 kg; ISI Marked Electronic Weighing Scale (Platform Scale) 1. Capacity: 150 kg 2. Accuracy: 20 g 3. Platter Size: 550 mm x 650 mm (Tolerance+/- 10 %), stainless steel made. 4. The body of the scale should be sturdy. 5. The Weighing Scale should have adequate Body Base Dimensions to maintain secure balance at the time of weighing. The Electronic weighing Scale (Platform Scale) should incorporate following features for user-friendly convenience: 1. Display: LED display with 5 digit, Size: Minimum height 14 mm 2. TARE function 3. The scale should have LED indications for A.C. On, Nett/Gross Weight, Zero, Battery, Battery Low. 4. The scale should have Memory Accumulation feature. 5. The Scale should have inbuilt rechargeable battery back up for minimum of 8 hrs. 6. Display Intensity should be adjustable, through keyboard, while operating on Battery for longer Battery back up. Make: Essae / Avery / Equivalent

3

-

-

... More
Weigh Balance (digital), 60 kg; ISI Marked Electronic Weighing Scale (Platform Scale) 1. Capacity: 60 kg 2. Accuracy: 2 g 3. Platter Size: 360 mm x 276 mm (Tolerance+/- 10 %), stainless steel made. 4. The body of the scale should be sturdy. 5. The Weighing Scale should have adequate Body Base Dimensions to maintain secure balance at the time of weighing. The Electronic weighing Scale (Platform Scale) should incorporate following features for user-friendly convenience: 1. Display: LED display with 5 digit, Size: Minimum height 14 mm 2. TARE function 3. The scale should have LED indications for A.C. On, Nett/Gross Weight, Zero, Battery, Battery Low. 4. The scale should have Memory Accumulation feature. 5. The Scale should have inbuilt rechargeable battery back up for minimum of 8 hrs. 6. Display Intensity should be adjustable, through keyboard, while operating on Battery for longer Battery back up. Make: Essae / Avery / Equivalent

3

-

-

... More
Weigh Balance (digital), 6 kg; ISI Marked Electronic Weighing Scale (Table Top) 1. Capacity: 6 kg 2. Accuracy: 1 g 3. Platter Size: 205 mm x 250 mm (Tolerance+/- 10 %), stainless steel made. 4. The body of the scale should be sturdy. 5. The Weighing Scale should have adequate Body Base Dimensions to maintain secure balance at the time of weighing. The Electronic weighing Scale (Table-Top) should incorporate following features for user-friendly convenience: 1. Display: LED display with 5 digit, Size: Minimum height 14 mm 2. TARE function 3. The scale should have LED indications for A.C. On, Nett/Gross Weight, Zero, Battery, Battery Low. 4. The scale should have Memory Accumulation feature. 5. The Scale should have inbuilt rechargeable battery back up for minimum of 8 hrs. 6. Display Intensity should be adjustable, through keyboard, while operating on Battery for longer Battery back up. Make: Essae / Avery / Equivalent

3

-

-

... More
Disposing of dismantling materials of R.C.C. stone/ brick masonry / derbies, excavated material etc from work site beyond the 5 km Spec. No.:As directed by Engineer in charge etc. complete. ( Beed District D.S.R, Page No. 125, Sr. No. 486 )

157.39

-

-

... More
Providing and laying Cast in situ/Ready Mix cement concrete in M-10 of trap / granite / quartzite / gneiss metal for foundation and bedding including bailing out water, Steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing if required and curing complete, with fully automatic micro processor based PLC with SCADA enabled reversibleDrum Type mixer/concrete Batch mix plant ( Pan mixer ) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) ) Spec. No. Bd. E. 1 Page No287 (S. S. R. I. No. 24.01 & P. No. 131)

9.9

-

-

... More
Providing and constructing Brick Masonry Inspection Chamber 60cm x 45cm x 90cm including 1:4:8 cement concrete foundation 1:2:4 cement concrete channels half round G.S.W. pipes, Brick Masonry, plastering from inside and with frame fixed in cement concrete with R.C.C. Cover medium duty 140 kg with frame etc complete. Spec. No. Bd.V.43 Page No.574. (S. S. R. I. No. 42.17 & Page No. 353 )

16

-

-

... More
Providing and laying concrete pipes of I.S. NP. class of 150mm diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete.. Spec. No. Bd.V.41, Page No. 573 (S. S. R. I. No. 42.07 & Page No. 351)

55.2

-

-

... More
Providing and fixing P.V.C. Rain water pipes of 160mm outer diameter and having wall thickness of 2.2 to 2.7 mm confirming to I.S. 13592-1992 including proper rainwater receiving recess with P.V.C. plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25mm to 40mm from face of wall a fixing with clips of approved quality and number ,filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on C.C. or masonry blocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All the P.V.C. fittings and additional 2 piece socket clips shall be got approved from engineer in charge etc. complete. (S. S. R. I. No. 42.85 & Page No. 355)

90

-

-

... More
Providing and fixing P.V.C. Rain water pipes of 110mm outer diameter and having wall thickness of 2.2 to 2.7 mm confirming to I.S. 13592-1992 including proper rainwater receiving recess with P.V.C. plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25mm to 40mm from face of wall a fixing with clips of approved quality and number ,filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on C.C. or masonry blocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All the P.V.C. fittings and additional 2 piece socket clips shall be got approved from engineer in charge etc. complete. (S. S. R. I. No. 42.87 & Page No. 355)

90

-

-

... More
RWH - Recharge Pit Providing and constructing recharge pit of 2.0m deep and 1.0m dia of pre-cast RCC rings with 6.5"diax25m deep bore well at the floor of recharge pit including installation of combination of solid/perforated PVC casing pipe wrappe d around with netlon mesh including 300mm thick side filling around out side of RCC rings (annular space)with 40 mm size boulders including filling of recharge pit up to 0.5m depth with 25-75mm clean washed gravels from bottom up followed by 0.5m depth of 10-25mm of clean washed stones followed by 0.5m of washed river fineaggregate naturalsand/crushedsandVSIgradefinelywashed etc.) including netlon mesh between each gravel /fineaggregate (naturalsand/crushedsandVSIgradefinelywashed etc.) medialayer including covering with RCC slab, manhole frame & cover, PVC rungs, PVC end-caps, fittings etc. including arrangement forinlet & outlet pipe excavation & back filling as shown in the drawing. The rate shall be inclusive of all labour, material, wastage,scaffolding,transportation,taxes, including all leads, lifts at all levels. All material should be of approved make. All works complete as per the drawing ,technical specification and direction of the Engineer in charge. (S. S. R. I. No. 48.47 & Page No. 405)

1

-

-

... More
Boring/drilling bore well of 300mm dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machinery required for the job, all complete as per direction of Engineer in charge, upto 90m depth below ground level. (S. S. R. I. No. 48.48 & Page No. )

75

-

-

... More
Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well-casing pipe of 150mm dia, conforming to IS:12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per the direction of Engineer in charge. (S. S. R. I. No. 48.49 & Page No. )

75

-

-

... More
RWH - Shallow Percolation Pit providing, constructing 2.0m deep shallow depth percolation pit comprising of 1.0m dia pre-cast RCC rings, 300mm thick side filling around outside of RCC rings (annular space) with 40mm size boulders including filling of percolation pit up to 0.5m depth (from bottom up) with 25-75mm clean washed gravels followed by 0.5m depth of 10-25mm of clean washed stones followed by 0.5m of washed river fine aggregate (natural sand/crushed sand VSI grade finely washed etc.) including netlon mesh between each gravel/fine aggregate (natural sand/crushed sand VSI grade finely washed etc.) media layer including covering with RCC slab, manhole frame & cover, PVC rungs etc. including arrangement for inlet & outlet pipe, excavation & backfilling as shown in the drawing. The rate shall be inclusive of all labour, material, wastage, scaffolding, transportation, taxes, including all leads, lifts at all levels. All material should be of approved make. All works complete as per the drawing, technical specification and direction of the Engineer in charge (S. S. R. I. No. 48.46 & Page No. 229)

3

-

-

... More
Providing and fixing mild steel grill work for windows, ventilators, etc. 15 kg/sqm as per drawing including fixtures necessary welding and painting with one coat of anticorrosive paint and two coats of oil painting complete.(SSR 201-22 Item No.39.31 Page No. )

0.56

-

-

... More
Providing and fixing P.V.C. Rain water pipes of 110mm outer diameter and having wall thickness of 2.2 to 2.7 mm confirming to I.S. 13592-1992 including proper rainwater receiving recess with P.V.C. plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25mm to 40mm from face of wall a fixing with clips of approved quality and number ,filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on C.C. or masonry blocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All the P.V.C. fittings and additional 2 piece socket clips shall be got approved from engineer in charge etc. complete.

7

-

-

... More
Providing and fixing chicken mesh of 22 gauge, with about 30 cm. width at the junction of R.C.C members and brick work, of approved quality including fixing mesh in position by necessary drilling in concrete /B.B.masonry and or tying by binding wire etc. complete. (S.S.R.2018-19 Item No 32.26 additional spec no. As directed by Engineer in Charge:(SSR 201-22 Item No.32.26 Page No.270)

25.41

-

-

... More
Providing waterproofing in W.C. and bath including brickbat coba in all position including providing and laying 12mm bedding in cement mortor 1:3 on vergin concrete slab with waterproofing compound @1kg/per bag of cement laying brickbat coba of required thickness in cm1:5with waterproofing compound1kg/bag of cement grouting and finishing the top layer with 20mm thick brick bedding in cm mortor 1:3 with waterproofing compound1kg/per bag of cement and testing the treated portion for 48 hours by pond test and covering ten years' guarantee on requisite stamppaper including curing etc. complete.(SSR 201-22 Item No.31.26 Page No. 267)

0.95

-

-

... More
Providing cement based waterproofing treatment to terraces(Indian waterproofing or alike)with brickbats laid in required slope to drain the water for any span after cleaning the base surface.Applying a coat of cement slurry admixed with approved waterproofing compound and laying the brickbats on bottom layer in C.M.1:5admixed with approved waterproofing compound filling upto half depth of brickbats,curing this layer for3days,applying cement slurry over this layer joint so fbrickbats with C.M.1:3 admixed with approvedwaterproofingcompoundandfinallytopfinishing with average 20mm.thick layers of same mortar added with jute fiber at 1Kg per bag including finishing the surface smooth with cement slurry admixed with approved waterproofing compound. Marking finished surface with false squares of 300mmx300mm. making the junctions at the parapet rounded and tapered top for required height,with drip mould at the junction of plaster and parapet and curing and covering 10 years Guarantee against leakproofness on Court fee stamppaper ofRs. 500/- including ponding test etc. complete.(SSR 201-22 Item No. 31.04 Page No. 263)

8.82

-

-

... More
Providing and applying Two coats of wall care Putty on plastered surface and Ceiling and Walls to prepare surface even and smooth of approved make, etc complete.(SSR 201-22 Item No.32.34 Page No.272 )

13.68

-

-

... More
Providing and laying chequered tiles ofapproved qualityof size 30cmx30cm, confirming to corresponding I.S.forflooring in required position laid on a bed of1:4 cement mortar including cement float,filling joint with cement slurry cleaning curing etc. compl

8

-

-

... More
Providing and laying Antiskid Ceramic tile sof approved quality of size 30cmx30cma nd confirming toI S15622-2006(Group-BIIA) for antiskid flooring in required positionlaidonabedof1:4 cement mortar including cement float,filling joint with cement slurry cleaning curing etc. complete.

13.86

-

-

... More
Providing and laying vitrified mirror/glossy finish tile s having size 590mmto605mmx590mm to 605mm of 8to10mm thickness and confirming to IS.15622-2006 (groupBla) of approved make,shade and pattern fordadoandskirting inrequired position fixed in 1:4 cemen

22.37

-

-

... More
Providing and fixing in position powder coated aluminium louvered windows / ventilator of various sizes with powder coating as per detailed drawing and specifications including aluminium rames 80 x 38 mm x 1.22 mm box type, 5 mm thick sheet glass louvers, of approved quality etc. complete.(SSR 201-22 Item No. 39.68 Page No.331 )

0.56

-

-

... More
Providing and fixing green marble of 18 to 20 mm thick for doorframe/ dado/ window boxing etc. On C.M. 1:6 including filling joints with polymer base filler nosing / moulding the sharp edges wherever necessary, curing, etc. complete.(SSR 201-22 Item No. 33.48 Page No.280 )

1.86

-

-

... More
Providing and Fixing 30MM thick BOTH SIDE PRELAMINATED SOLID PANEL PVC DOOR SHUTTER consisting of frame made out of M.S tubes of 19 guage thickness and, size19x19mm for styles and15x15mm for the top and bottom rails, M.S frames hall have acoatofmetelprimer of approved make and manufacture. M.S frame shall be covered withheatmouledPVC'C'channelmadefrom 5mm (+/0.25)thick prelaminated sheet of density 600kg/cbm, ofsize30mm thickness 70mm widthout of which 50mm shall be flat and 20mm shall be tapered in 45? angle on either side for mingstiles;and 5mm thick,95 mm wide PVCsheet out of which 75mm shall be faltand 20mm shall be tapered in 45 on the inner side to form top and bottom railand 115mm wide PVC sheet out of which 75mm shall be faltand 20mm shall be tapered on both sides toform lockrail.Top, bottom and lockrailshall be provide deithersideofthepanel.Anadditional5mm(+/0.25)thickPVCstripof20mmwidthistobestuckonthebottomsideofthe'c'channelprelaminatedpanelingof5mm(+/0.25)thickPVCsheettobefittedinsidetheM.S.framewelded/sealedtothestylesandrailswith5mm(+/0.25)x30mmPVCsheetbeadingoneithersideandjoinedtogetherwithsolventcementadhesiveetc,10mmthickness(5mm(+/0.25)x2nos)20mmwidecrossPVCsheetasgapinsertfortherailandbottomrail.Doortobefixedtoframeswith3nosM.S.powdercoatedbuthingesofsize100mmx25MMx2mmusing32mmlongsteelscrewsdrilledsuitabletopassthroughboththewallsoftheM.Stube.Otherhardwaresshouldbefixedwith19x6mmsizesteelscrewsincludingfixturefasting.Complete as per direction of engineer in charge.

1.58

-

-

... More
Providing and fixing 450mmx550mm size superior type Belgium mirror with 16mm dia. nickel plated towel rod etc. complete.

1

-

-

... More
Providing and fixing 900mm high S.S.304 Grade Stainless steel railing with 40mm diameter and 1.5mm thick at top, 40mm diameter and 1.5mm thick vertical supports spacedat 1.5 mcenter to center and 8mm thick toughened glass including fabricating, fixtures, errecting, necessary welding, grinding ,finishing,buffing to stainless steelpipeetc. complete

18

-

-

... More
Plumbing

-

-

-

... More
Providing and fixing coloured glazed earthenware wash hand basin of 63 cm x 45 cm Size including cold water pillar tap / cold and hot water pillar tap brackets, rubber plugs and brass chain, stop tap and necessary pipe connection including P.V.C. waste pipe and trap up to the outside face of the wall.. (SSR 201-22 Item No. 41.74 Page No. 349)

1

-

-

... More
Providing and fixing C.P. pillar cock long neck with aerator of approed make including necessary sockets/union nut etc. complete. (SSR 201-22 Item No.42.82 Page No. 361)

1

-

-

... More
Providing and fixing C.P. Angular stop clock with wall flange of approved make continental including necessary sockets / union nut etc. complete.(SSR 201-22 Item No.42.79 Page No. 361)

1

-

-

... More
Providing and fixing C.P. BIB cock with wall flange of approved make including necessary sockets/ union nut etc. complete. (SSR 201-22 Item No.42.83 Page No. 361)

1

-

-

... More
Providing and fixing H.D.P container Syntex or alike one piece moulded water tank made out of low density polythyler and built corrugation including of delivery upto destination hoisting and fixing of accessories such as inlet, outlet over flow of all tanks capacity above 1000 to 20,000 litres Spec. No. As directed by engineer incharge. (SSR 201-22 Item No. 42.58 Page No. 358)

2000

-

-

... More
Providing and fixing on Walls / Ceiling / Floor 25 mm Dia. CPVC Pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Spec. No. BD.V 5 page 551 and as directed by Engineer in charge (SSR 201-22 Item No.42.57 Page No.359 )

4

-

-

... More
Providing and fixing on Walls / Ceiling / Floor 32 mm Dia. CPVC Pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Spec. No. BD.V 5 page 551 and as directed by Engineer in charge (SSR 201-22 Item No. 42.58 Page No. 359)

2

-

-

... More
Providing and fixing on Walls / Ceiling / Floor 40 mm Dia. CPVC Pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Spec. No. BD.V 5 page 551 and as directed by Engineer in charge (SSR 201-22 Item No. 42.59 Page No. 359)

2

-

-

... More
Providing and fixing on Walls / Ceiling / Floor 50 mm Dia. CPVC Pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Spec. No. BD.V 5 page 551 and as directed by Engineer in charge (SSR 201-22 Item No.42.60 Page No.359)

8

-

-

... More
Providing and fixing on Walls / Ceiling / Floor 15 mm Dia. CPVC Pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Spec. No. BD.V 5 page 551 and as directed by Engineer in charge (SSR 201-22 Item No.42.55 Page No. 358)

15

-

-

... More
Providing and fixing 15 mm. dia Ball cock medium type with PVC float including sockets and necessary fittings and tested as per municipal requirements etc. complete. Spec. No. As Directed By Engineer In Charge. (SSR 201-22 Item No. 42.37 Page No.355 )

15

-

-

... More
Providing and fixing 40 mm. dia Ball cock medium type with PVC float including sockets and necessary fittings and tested as per municipal requirements etc. complete. Spec. No. As Directed By Engineer In Charge. (SSR 201-22 Item No. 42.36 Page No. 355)

1

-

-

... More
Providing and fixing European type wall-hung white water closet of approved make with push valve concealed type with cover plate 32mm size of approved make including soil pipe, vent pipe up to outside face of wall ,100mm dia. G.I. plug bend inlet pipe all fittings, cuttingand making good walls, floors etc. complete ((SSR 201-22 Item No. 42.86 Page No.362 )

1

-

-

... More
Providing and constructing Brick Masonry Inspection Chamber 90cm x 45cm x 90cm including 1:4:8 cement concrete foundation 1:2:4 cement concrete chanels half round G.S.W.pipes, Brick Masonry, plastering from inside and C.I. lid cover of 75 kg with lid and frame fixed in cement concrete (SSR 201-22 Item No. 42.11 Page No.352 )

1

-

-

... More
Providing , laying and fixing ,jointing Eco- drain 200 mm SN 4 Nu-Drain Upvc pipes or of equivalent make, manufacture as per EN 13476 or equivalent as per I.S.15328 with fittings such a bends, tees tees, coupler etc, jointing with rubber lubricant including necessary excavation, trench refilling with selective excavated materialetc.complete.(SSR 201-22 Item No. 43.32 Page No.371 )

10

-

-

... More
Garden soils :- Supplying one side fresh garden soil well sieved 90% to pass through IS sieve of 10 mm size free from stone rubbish like dried grass root & other such materials the soil should be fresh from quarry. The colour of the soil generally be red. The soil will be measured by measuring box. (Item include Royalty charges. Corporation types transporting loading Unloading etc. complete. Horticulture DSR 1/2

3.75

-

-

... More
Suplying & laying well quality of manuar required for small, large tress including mixing with soil , watering, transportation at site etc. completed Horticulture DSR 2/2

3.75

-

-

... More
Saplings of flowering/shadytrces Gulmohar, Raintree, Peltophorum etc (one year old) Horticulture DSR 8/3

25

-

-

... More
Saplings of Small & medium Ornamental flowering plants , Thuja,Cupresus plants ornamental Ficus, Mussanda etc. Horticulture DSR 9/3

60

-

-

... More
Rose Plant :- Excavating pit with size 0.3x0.3x0.3 meter removing & conveying unwanted stuff of a required distance as directed filling the fresh garden soil in minor in 3:1 proportion to a required height of 0.3 meter mixing the soil & minor levelling, watering on previous night. Planting 40 to 50 cm height healthy plant of required rose verity mainaining till well established by watering weeding, sturring,prunning, replacing the casualities etc. complete. Horticulture DSR 9/5

20

-

-

... More
Mogra Plant/Creepers/Climbers:- Excavating pit with size 0.3x0.3x0.3 meter removing & conveying unwanted stuff of a required distance as directed filling the pit upto excavated material upto a height 15 cm. & ramming height of 15 cm. with fresh garden soil in minor in 3:1 proportion mixing the soil & minor levelling, watering on previous night. Planting (one year old) healthy plant as per specification mainaining till well established by watering weeding, sturring,prunning, replacing the casualities etc. complete. Horticulture DSR 10/6

20

-

-

... More
Planting large flowering/shady trees:- Digging pit with size 0.9 x 0.9 x 0.9 meter. Removing & conveying unwanted stuff of a required distance as directed filling the pit upto excavated material upto a height 30 cm. & ramming height of 60 cm. with fresh garden soil in minor in 3:1 proportion mixing the soil & minor levelling, watering on previous night. Planting (one year old) healthy trees sapling as per specification mainaining till well established by watering weeding, sturring of soil replacing of casualities etc. complete. Horticulture DSR 12/6

20

-

-

... More
Planting small & medium size ornamental flowering plant:-Digging pit with size 0.6 x 0.6 x 0.6 meter. Removing & conveying unwanted stuff of a required distance as directed filling the pit with fresh garden soil & farm yard minor upto a height of 0.6 meter in 3:1 proportion mixing the soil & minor levelling, watering on previous night. Planting (one year or two year old) healthy plant sapling as per specification mainaining till well established by watering, weeding, sturring of soil replacing of casualities etc. complete. Horticulture DSR 11/6

20

-

-

... More
Preparing instant Lawn :- Excavating the ground to a required depth of 20 cm. removing & conveying unwanted stuff to a required distance as directed filling fresh garden soil in minor in 3:1 proportion to a height of 20 cm. mixing soil & minor throughly well levelling with required slope light watering on previous night, rolling on surface. Fixed readymade lawn truf rolls or slab of reqired verity as directed. ramming on it for proper fixing & mainaining till well establish by watering, weeding, clipping or moving etc. complete. Horticulture DSR 3/4

6.25

-

-

... More
Preparing Edging or border:- Excavating the ground to a required depth of 20 cm. removing & conveying unwanted stuff to a required distance as directed filling fresh garden soil in minor in 3:1 proportion to a required height of 20 cm. mixing , levelling , watering the same planting suitable verity of edging plants & rooted cutting at distance of 15 cm. between plants to plants and row to row watering & maintaining till well grown to te stage of prunning Horticulture DSR 4/4

15

-

-

... More
Preparing Shrubbery:- Excavating the ground to a required depth of 30 cm. removing & conveying unwanted stuff to a required distance as directed. Providing and filling fresh garden required distance as directed. Providing and filling fresh garden soil and manure in excavated area in 3:1 proportion to a required height of 30 cm. Mixing , levelling , watering on previous night. Planting well rooted shrubs 0.5 mtrs. apart as directed and maintaining till well established by watering, weeding, strring replacing of casualties etc. complete. Horticulture DSR 8/5

7.5

-

-

... More
Dustbin 240 Litre Blue WB-240 Dimensions : 725 x 580 x 1075 mm ( 107x72x58cm ) Heavy Duty Sunproof Waste Garbage Bins Wheeled Bins Easy to maintain & Use Envirnoment Friendly Long Lasting Capacity : 240 Litre (Non SSR)

5

-

-

... More
Disposing of dismantling materials of R.C.C. stone/ brick masonry / derbies, excavated material etc from work site beyond the 5 km Spec. No.:As directed by Engineer in charge etc. complete. (Beed District D.S.R, Page No. 125, Sr. No. 486)

14.2

-

-

... More
Covid-19 Health and safety: Providing and making necessary arrangements of various essential materials and items of recommended quality and make as per guidelines of the health department required for prevention of COVID-19 pandemic in consideration of health and safety management of man power at construction site 1. Hand Sanitizer.: 50 liters 2. Disinfectant. : 30 Liters 3. Sodium Hypochlorite. : 30 KG 4. Fogging machine and Liquid for sanitization.: 1 Number 5. 3 Ply Face Mask of good quality. : 500 Numbers 6. Surgical / Latex Gloves of good quality.: 200 Pairs 7. Rubber Gloves of good quality.: 100 Pairs 8. Empty Spray Bottles 100 ml (Plastic).: 20 Numbers 9. Empty Spray Bottles 1000 ml (Plastic).: 5 Numbers 10. PPE kits. : 10 Numbers 10. Temperature Guns. : 3 Numbers 11. Face shield : 30 Numbers

1

-

-

... More
Electromechanical work

-

-

-

... More
Pallets Dimensions: 1000mm X 1200mm X 150 mm approx. ht Colour: as approved by client Pallet type: four side fork opening Weight carrying capacity: 1500 Kg Suitable to use with all kind of material handling equipments including hand pallet trucks etc. Working Temperature range: (-) 25 deg C to (+) 10 deg C heavy duty type, Top Deck : Perforated MOC Shall be food grade plastic/HDPE and shall have excellent impact strength and high compression resistance.

100

-

-

... More
Overhauling of Machineries for 1 precooling chamber, 4 cold rooms ,ante-room , transformer, DG sets, HT/LT/APFC panels and other electrical system, dock,grading sorting line and overall any activity not mentioned but needed to carry out utilizing the equipment in effective manner. It is recommended that bidder shall visit the site and get the idea of quantom of work before quoting.

1

-

-

... More
The details of the exisiting machinery is as follows, • PRE-COOLING CHAMBER:1 no, CDU (2 nos), Air Handling Unit 43 kW capacity, water pump: 1 x 3 Kw, 1 no • Cold Storage 1,2,3,4: CDU: air cooled condensing unit 1 no for each room., Air Cooling Unit: 13.5 KW each unit • Ante-room: Air cooled condesing nuit and indoor unit 1 nos • Evaporative air cooling units: Qty-2 nos • Air curtains, QTY: 13 Nos. • Grading Sorting Lines • Transformer: 200 KVA • DG set: 200 KVA • 11 KV Outdoor type MCCB panel • Main PCC panel • APFC panel:microcontroller based. • Lighting fixtures: internal as well as external street lighting of different wattage

-

-

-

... More
Scope of Work for Refrigeration System: • Checking of operational log readings recorded by operators during the previous month.& Discussion operational problems, if any, with maintenance/operation staff. • Checking the actual performance of the machines and Checking & correcting the set parameters, if required. • Carrying out minor repairs. Replace minor parts ,if required. • Making recommendations to client for smooth & trouble free operation of the machines. • Cleaning & combing of ACU’s fins, suction filters, driers, pump ,strainers etc. •ACU fan & motor- routine & preventive maintenance • To check oil level in the compressor, if less then oil to be charged in to the compressor. • Check liquid sight glass to determine the shortage of refrigerant if any / to check moisture contained in the system. Top up if required. • Inspect system for visible signs of leaks. If found, attend the leaks. If any brazing work involved should be carried out by the contractor at his cost • Inspect & adjust, if required, all safety controls. • carrying out calibration of gauges, temperature , RH sensors etc, wherever caliberation time frame has exceeded • Inspect the condition of refrigerant and drain pipe insulation (drain pipe insulation wherever applicable).To be replaced if found not in good condition. • Condenser inlet air pre-cooling system - to be cleaned, pump repaired (if required), pipig cleaned and other routine and preventive maintenance.

-

-

-

... More
Scope of Work for Insulated Sandwich Panels: • Insulated Panel Structure: Filling of silicon sealant as & where required to stop air leakages if any. • Floor Insulation – checking for gaps created between civil floor and wall insulation and sealing the same with silicon sealant / PUF filling depending on the size of the gap, if created during regular wear and tear or minor damage. • PUF foaming in case condensation due to leakage etc found. Scope of Work for Insulated Doors, Strip and Air curtains, Dock shelters: • Cleaning and oiling of rollers of doors • Gasket checking for leakage. Alignment of gasket if leakage is observed. • Replacement of gasket if gasket is damaged or found in improper condition. • P.V.C. strip Curtains: Replacement of PVC strips if any. • Air Curtains – check the overall condition. Replacement of blower/full unit, if required. • Dock shelter- check for any damage, leackage etc. appropriate action to be taken to so as to make them fully funcational. • Dock leveller: cleaning, lubricating the parts with proper lubracants, All necessary components are adjusted properly to make sure equipment works smoothly and consistently.check fluid level in hydraulic cylinders, top-up/ replace the fluid as may be necessary.

-

-

-

... More
Scope of work for Electrical System: • Transformer: oil condition checking, leakages to be attended, testing of oil for various parameters as per standard practice, Filtration or replacement / top up of oil as per condition of oil, Insulation resistance of the transformer should be checked, Bushings should be cleaned and inspected for any cracks, checking of any loose connections of the terminations of HV & LV side, breather examination. Dehydration of Silica gel if necessary. Explosion-vent diaphragm examination. Conservator to be cleaned from inside. Cleanliness in the Substation yard with all nets, vines, shrubs removed. • DG set: Routine & preventive maintenance of DG sets with AMF panels including maintenance of controlling/protective accessories, battery check. Replace/charge as required. DG set general servicing as per manufacturers recommendation. replacement of filters etc. as required. •HT / LT panels: Check for loose connection of all terminals in the panels, Clean gently the dust by air pressure in side the panels, Check the mounting of CTs for its position, ensure that does not make contact with body, Check for loose connections for all power / neutral cable connections, Check for all the fuses, Check for loose connections of all power cables & control cables of panel, Check for loose connections of cables of meters / contractors, Check the outgoing & incoming phase, neutral connection of circuit breaker, Check the thermal trip of circuit breaker, Check mountings of circuit breaker & tightness of power cables. If anything mentioned above found not normal, same shall be rectified • APFC panel: Cleaning should done by using blower. Microcontroller not working condition to be replaced. Current of each capacitor should be measured and recorded once in month to know healthiness of each capacitor bank. Current should be measured by using clamp tester. If the value of current is less than 50% of the rated value. Capacitor should be replaced with new one. Connections should be checked for any loose connections. • Routine, preventive maintenance of Lighting & Power Distribution Systems. • Routine, preventive maintenance of HT, LT cables & Wirings. • Earth resistance measurement of all the Earth electrodes • Checking, fitting cleaning and fault rectification of the lighting fixtures

-

-

-

... More
Scope of Work for Grading Sorting Line: • Motor - checking of alignment of motors • Bearing at various locations to be checked and oiled / greased wherever necessary • Lubrication to be carried out for all the rollers as necessary to avoid any squeaking noises. • Belt alignment • Pulley conditon checking • Heaters operation check and routine & preventive maintenance for dryer and hot water treatment units. • Washer Unit: water spray nozzels, brushes etc checking and routine maintenance. • Electronic weight sizer: routine & preventive maintenance. • Electrical control panel: routine & preventive maintenance. • Painting of parts wherever necessary to prevent parts from being rusted. Overall the grading sorting machineries are to be cleaned and made ready for use considering that they may be used for export oriented purpose. Parts that are coming in contact with the product during operation should be ensured to be of allowable SS or other food grade material. If any part like motor etc. needs replacement, then the cost of the motor / major part would be borne by the end-user / MSAMB / user but the installation and commissioning of the part shall have to be done as part of this contract and the labour costs and minor accessories for the same to be considered. For this, a site visit for seeing the condition of the equipment is extremely critical.

-

-

-

... More
Evaporative air cooling units: • Remove the filer pads and clean them thoroughly with a pressurized water jet • Water Sump cleaning • Water pump routine & preventive maintenance • Fan and Belts- check condition, preventive and routine maintenace • Air leaks in ducting and Water Leaks- check and attend if any • Electircal & contro System- checking, preventive and routine maintenace

-

-

-

... More
Export Facility Center, Savda, Taluka Raver, District Jalgaon

-

-

-

... More
PART A : Work Portion

-

-

-

... More
Civil Work

-

-

-

... More
Clearing grass and removal of rubbish up to a distance of 50 metre outside the periphery of the area S.S.R.2021-22 Item No. 2.07 .

716.98

-

-

... More
Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 m beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting, dewatering etc. complete. (Lift upto 1.5 m.) by Mechanical Means. S.S.R.2021-22 Item No. 21.02

633.62

-

-

... More
Excavation for foundation in hard murum including removing the excavated material upto distance of 50 metres beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting, dewatering etc. complete. (Lift upto 1.50 m) by Mechanical Means.. S.S.R.2021-22 Item No. 21.06

167.42

-

-

... More
Excavation for foundation in Hard murum and boulders including removing the excavated material upto a distance of 50 metres, beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting, dewatering etc. complete. (Lift from 1.5 m to 3.0 m) by Mechanical Means. S.S.R.2021-22 Item No. 21.12

115.68

-

-

... More
Providing preconstructional antitermite treatment as per I.S. 6313 (Part-II) by treating the bottom surface and sides of excavation at the rate of 5 litres of emulsion concentrate of 1.0 percent of chlorophyrifos per square meter of surface area covering 10 years guarantee on bond paper. S.S.R.2021-22 Item No. 21.22

1100.88

-

-

... More
Providing preconstructional antitermite treatment as per I.S. 6313 (Part-II) by treating the top surface of plinth filling at the rate of 5 litres of emulsion concentrate at 1.0 percent of clorophyrifos per square metre of surface area covering ten years guarantee on bond paper. S.S.R.2021-22 Item No. 21.24

1099.74

-

-

... More
Filling in plinth and floors with contractors soil. Sand or murum materials in 15 cm to 20 cm layers including watering & compaction complete. S.S.R.2021-22 Item No. 21.37

929.98

-

-

... More
Providing soling using 80mm size trap metal in 15 cm. layer including filling voids with crushed sand /grit ramming, watering complete. S.S.R.2021-22 Item No. 21.40

249.89

-

-

... More
Providing and laying Cast in situ/ Ready Mix cement concrete M-15 of trap/ granite/ quartzite/ gneiss metal for coping to plinth or parapet, moulded or chamfered as per drawing or as directed including steel centering, plywood/ steel formwork compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed). With fine aggregate (Crushed sand V.S.I. Grade). S.S.R.2021-22 Item No. 24.16

5.93

-

-

... More
First Floor

1.92

-

-

... More
Providing and laying Cast in situ/ Ready Mix cement concrete in Mix-15 of trap/ granite/ quartzite/ gneiss metal for bed blocks, foundation blocks and such other items including bailing out water, plywood/ steel formwork, laying/ pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.), with fully automatic micro processor based Programmable Logic Controller with Superwisery Control and Data Acquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand V.S.I. Grade). S.S.R.2021-22 Item No. 24.08

236.22

-

-

... More
Providing and laying in situ/ Ready Mix cement concrete M-25 of trap/ granite/quartzite/ gneiss metal for R.C.C. work in foundations like raft, strip foundations, grillage and footings of R.C.C. columns and steel stanchions etc. including bailing out water, formwork, laying/ pumping cover blocks, compaction and curing roughening the surface if special finish is to be provided, (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based PLC with SCADA enabled Reversible Drum Type mixer/ concrete Batch Mix plant (Pan mixer) etc. complete, with fine aggregate (Crushed sand V.S.I. Grade). S.S.R.2021-22 Item No. 25.13

156.63

-

-

... More
Providing and laying cast in situ/ Ready Mix cement concrete M-25 of trap/ granite/ quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawing or as directed including centering, formwork, cover blocks, laying/ pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete, (Excluding reinforcement and structural steel) with fully automatic micro processor based PLC with SCADA enabled Reversible Drum Type mixer/ concrete Batch Mix plant (Pan mixer) etc. complete with fine aggregate (Crushed sand V.S.I. Grade). S.S.R.2021-22 Item No. 25.33

92.4

-

-

... More
First Floor

21.41

-

-

... More
Second Floor

1.13

-

-

... More
Providing and laying Cast in situ/ Ready Mix cement concrete M-25 of trap/ granite/quartzite/ gneiss metal for R.C.C. Beams and Lintels as per detailed designs and drawings or as directed including centering, formwork, cover blocks, laying/ pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel), with fully automatic micro processor based PLC with SCADA enabled Reversible Drum Type mixer/ concrete Batch Mix plant (Pan mixer) etc. complete with fine aggregate (Crushed sand V.S.I. Grade). S.S.R.2021-22 Item No. 25.52

150.51

-

-

... More
First Floor

35.52

-

-

... More
Second Floor

2.32

-

-

... More
Providing and laying Cast in situ/ Ready Mix cement concrete M-25 of trap/ granite/ quartzite/ gneiss metal for R.C.C. Chajja as per detailed design and drawings including centering, formwork, cover blocks compacting , curing , finishing and roughening the surface if special finish is to be provided and curing complete (Excluding reinforcement and structural steel), with fully automatic micro processor based PLC with SCADA enabled Reversible Drum Type mixer/ concrete Batch Mix plant (Pan mixer) etc. complete, with fine aggregate (Crushed sand V.S.I. Grade). S.S.R.2021-22 Item No. 26.07

19.98

-

-

... More
First Floor

1.98

-

-

... More
Providing and laying Cast in situ/ Ready Mix cement concrete Mix-25 of trap/ granite/ quartzite/ gneiss metal for Reinforced Cement Concrete Slabs and Landings as per detailed designs and drawings including centering, formwork, cover blocks, laying/ pumping, compactionfinishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete, (Excluding reinforcement and structural steel) with fully automatic micro processor based Programmable Logic Controller with Superwisery Control and Data Acquisitionenabled Reversible Drum Type mixer/ concrete Batch Mix plant (Pan mixer) etc. complete, with fine aggregate (Crushed sand V.S.I. Grade). S.S.R.2021-22 Item No. 25.72

103.6

-

-

... More
First Floor

54.53

-

-

... More
Second Floor

2.76

-

-

... More
Providing and fixing in position TMT FE -500 bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules, including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete. S.S.R.2021-22 Item No. 26.33

62.88

-

-

... More
First Floor

12.22

-

-

... More
Providing and fixing solid core flush door shutter in single leaf 32 mm thick decorative type of exterior grade as per detailed drawings approved face veneers 3 mm thick on both faces or as directed, all necessary beads, mouldings and lipping, wrought iron hold fasts, chromium plated fixtures and fastenings, with brass mortise lock, chromium plated handles on both sides, and finishing with French Polish etc. complete. S.S.R.2021-22 Item No. 39.09

21

-

-

... More
First Floor

15.75

-

-

... More
Providing and fixing rolling shutter fabricated from steel laths of minimum thickness 0.9 mm. with lock plate of 3.15 mm. thickness reinforced with 35 x 35 x 5 mm. angle section fitted with sliding bolts and handles for both sides, deep M.S. channel section of depth and thickness not less than 65 mm. and 3.15 mm. respectively with hold fast arrangements, M.S. Bracket plate 300 x 300 x 3.15 mm. minimum size and shape with square bar, suspension shaft of minimum 32 mm. diameter, hood cover of M.S. sheet not less than 0.9 mm. thickness and of any size at top and safety devices including mechanical gear operation arrangement consisting of worm gear wheels and worms of high grade cast iron or mild steel and one coat of red lead primer etc. complete. (I.S. 6248-1979) (Without mechanical gear). S.S.R.2021-22 Item No. 39.24

18

-

-

... More
Providing and fixing in position (as per 1868:1982) Aluminium sliding window of three tracks with rectangular pipe 95 x 38.10 x 0.90 mm. at weight 0.637 kg/Rmt. with window frame bottom track section 92 x 31.75 x 1.30 mm. at weight 1.070 kg/Rmt. Top and side track section 92 x 31.75 x 1.30 mm. at weight 0.933 kg/Rmt. The shutter should be of bearing bottom 40 x 18 x 1.25 mm. at weight 0.417 kg/Rmt. Inter locking section 40 x 18 x 1.10 mm at weight 0.469 kg/Rmt. and handle and top section 40 x 18 x 1.25 mm. at weight o.417 kg/Rmt. As per detailed drawings and as directed by Engineer-in-charge with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 mm. thick plain glass and aluminium mosquito net shutter with stainless steel jail with all required screws and nuts etc. complete with powder coating with box. S.S.R.2021-22 Item No. 39.43

45.3

-

-

... More
First Floor

23.4

-

-

... More
Providing and fixing mild steel grill work for windows, ventilators 20 kilogram per square metre as per drawing including fixtures, necessary welding and painting with one coats of anticorrosive paint and two coats of oil painting complete. S.S.R.2021-22 Item No. 40.01

44.96

-

-

... More
First Floor

28.2

-

-

... More
Providing fly ash brick masonary with conventional / I.S. type fly ash bricks in cement mortar 1:6 in foundation and plinth including bailing out water manually, striking joints, racking out joints, watering and scaffolding complete. S.S.R.2021-22 Item No. 27.12

82.51

-

-

... More
Providing fly ash brick masonary with conventional / I.S. type fly ash brick in cement mortar 1:6 for superstructure including striking joints, racking out joints, watering and scaffolding complete. S.S.R.2021-22 Item No. 27.13

146.32

-

-

... More
First Floor

102.4

-

-

... More
Second Floor

25.14

-

-

... More
Providing and laying Polished Kota stone flooring with Hand-Cut Polished Kota Stones 25 mm. to 30 mm. thick and required width in plain/ diamond pattern on bed of 1:6 cement mortar including cement float, filling joints with neat cement slurry, curing, cleaning and Mirror Polishing etc. complete. Note- Water absorption for Kota stone should not exceed 0.05%.( Item to be used with prior permission of Superintending Engineer ) S.S.R.2021-22 Item No. 33.75

512.2

-

-

... More
First Floor

327.98

-

-

... More
Providing sills of Granite 20 mm. to 25 mm. thick, on a bed of 1:4 cement mortar including cement float, filling joints with neat cement slurry, curing, polishing, rounding edges and cleaning complete. S.S.R.2021-22 Item No. 33.22

28.45

-

-

... More
First Floor

20.56

-

-

... More
Providing and laying polished machine cut machine polished Kotah stone slabs 20 to 25 mm thick for treads and risers of steps and staircases, with rounded nosing for the treads on a bed of 1:4 cement mortar including cement float, filling joints with neat cement slurry, curing, polishing and cleaning complete. S.S.R.2021-22 Item No. 33.18

14.35

-

-

... More
First Floor

16.56

-

-

... More
Providing internal cement plaster 12 mm. thick in single coat in cement mortar 1:5 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete. S.S.R.2021-22 Item No. 32.03

457.98

-

-

... More
First Floor

500.24

-

-

... More
Second Foor

38.89

-

-

... More
Providing internal cement plaster 6 mm. thick in a single coat in cement mortar 1:3 without neeru finish to concrete surface in all positions including scaffolding and curing etc. complete. S.S.R.2021-22 Item No. 32.02

488.88

-

-

... More
First Floor

373.65

-

-

... More
Second Floor

14.4

-

-

... More
Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 mm. thick in cement mortar 1:4 using waterproofing compound at 1 kg per cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 mm. thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc.complete. S.S.R.2021-22 Item No. 32.11

2438.79

-

-

... More
First Floor

464.97

-

-

... More
Second Floor

44.07

-

-

... More
Providing and applying priming coat over concrete/Masonry/Asbestos cement plastered surfaces including scaffolding if necessary, preparing the surface by thoroughly cleaning oil, greese, dirt and other foreign matter and sand papering as required etc. complete. S.S.R.2021-22 Item No. 35.21

801.35

-

-

... More
First Floor

873.89

-

-

... More
Second Floor

53.29

-

-

... More
Providing and applying plastic emulsion paint of approved quality, colour and shade to old/ new surfaces in two coats including scaffolding, preparing the surface. (excluding the primer coat) complete. S.S.R.2021-22 Item No. 36.12

1331.54

-

-

... More
First Floor

873.89

-

-

... More
Second Floor

53.29

-

-

... More
Providing and applying two coats of exterior acraylic emulsion paint conforming to corresponding I.S.of approved manufacture and of approved colour to the plastered surfaces including cleaning, preparing the plaster surface, applying primer coat, scaffolding if necessary and watering the surface for two days etc. complete. S.S.R.2021-22 Item No. 35.25

2640.14

-

-

... More
First Floor

464.97

-

-

... More
Second Floor

44.07

-

-

... More
Providing and applying two coats of synthetic enamel paint of approved colour to new/ old structural steel work and wood work in buildings, including scaffolding if necessary, cleaning and preparing the surface (excluding primer coat) etc. complete. S.S.R.2021-22 Item No. 35.07

36

-

-

... More
Providing and applying water proofing treatment using acrylic polymer modified cement based water proofing coating with fibre glass mesh mixing at the rate of powder to liquid (2:1) by weight covering 9 to 10 sqm /kg with two coats using Dr. Fixit or alike of chemicals for masonry and concrete surface by brush covering 7 years guarantee on Stamp Papers etc. complete. S.S.R.2021-22 Item No. 31.09

504.1

-

-

... More
First Floor

423.31

-

-

... More
Providing and laying Cast in situ/ Ready Mix cement concrete in M-25 of trap / quartzite /granite /gneiss metal for R.C.C. Waist Slab, and steps of staircases as per detailed design and drawings or as directed including steel centering, plywood/ steel formwork, steel props, laying/ pumping, compaction, finishing uneven and honeycombed surface with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing etc. complete, with fully automatic micro processor based PLC with SCADA enabled Reversible Drum Type mixer/ concrete Batch Mix plant (Pan mixer) etc. complete, with fine aggregate (Crushed sand V.S.I. Grade). (Excluding einforcement, including cover block).(Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin ). S.S.R.2021-22 Item No. 26.26

-

-

-

... More
First Floor

2.59

-

-

... More
Providing structural steel work in trusses, other similar trussed purlins and members with all bracing, gusset plates etc. as per detailed designs and drawings or as directed including cutting, fabricating, hoisting, erecting fixing in position, Making riveted/bolted/welded connection and one coat of anticorrosive paint and over it 2 coats of oil painting approved quality and shade etc. complete.

-

-

-

... More
First Floor

4.17

-

-

... More
Providing and fixing colour coated Zincalume ( R ) AZ150 ( min 150 gms/sq.mt. total on each side ) profiled sheets for roofing. The feed material is manufactured out of nominal 0.45 mm Base Metal Thickness ( BMT ) (0.5 mm TCT ), Hi-strength steel with min.550 MPa yield strength, metallic hot dip coated with Aluminium-Zinc alloy (55% aluminium 43.4% zinc 1.6% silicon) with COLORBOND ( R ) steel quality super durable polyester paint coat ( with inorganic pigment). The paint shall have a total coating thickness of nominal 35 um, comprising of nominal 25 um exterior coat on top surface and nominal 10 um reverse coat on back surface. Profile sheet shall have nom. 950-1050 mm effective cover width and nominal 25-30 mm deep ribs with subtle square fluting in the five pan at nominal 180-250 mm center-to-center. The end rib shall be designed for anti-capillary groove. and return leg. The feed material should have coil manufacturers product details marked a regular interval. Including fasteners with min. fastened with min. 25 um Zinc-Tin alloy coated, Hex head, self-drilling screw etc. complete. (weight of profile 4.52 kg/sqm) S.S.R.2021-22 Item No. 38.34

-

-

-

... More
First Floor

263.9

-

-

... More
Providing and fixing fibre glass reinforced polyster door shutter 30 mm. thick as per IS 14856 (2000) (Reaffirmed 2006) without ventilator including chromium plated fixtures and fastening with chromium plated handles on both sides, etc. complete. S.S.R.2021-22 Item No. 39.58

7.14

-

-

... More
First Floor

6.3

-

-

... More
Providing and Fixing Rollar Blinds AMI Make or approved make & shade of 38mm round Aluminium channel with Blackout fabric & telting with chain (Ball) system with all necessary fixtures and fitting etc. complete. (Sample to be final by Engineer In-charge prior execution of work) S.S.R.2021-22 Item No. 51.19

-

-

-

... More
First Floor

23.4

-

-

... More
Providing and fixing in position powder coated aluminium louvered windows/ ventilator of various sizes with powder coating as per detailed drawing and specifications including aluminium frames 80 x 38 mm x 1.22 mm box type, 5 mm thick sheet glass louvers, of approved quality etc. complete. S.S.R.2021-22 Item No. 39.68

1.76

-

-

... More
First Floor

1.2

-

-

... More
Providing Second class fly ash brick masonry with conventional / I.S. type bricks in cement mortar 1:4 in half brick thick wall including mild steel longitudinal reinforcement of two bars of 6 mm diameter/ two hoop iron strips 25 mm x 1.60 mm at every third course, properly bent and bounded at ends scaffolding raking joints and watering etc. complete. S.S.R.2021-22 Item No. 27.14

-

-

-

... More
First Floor

33.5

-

-

... More
Providing and laying Antiskid Ceramic tiles of approved quality of size 30 cm. x 30 cm. and conforming to I.S.15622-2006 (Group-B IIA) for antiskid flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with cement slurry cleaning curing etc. complete. S.S.R.2021-22 Item No. 33.67

24.06

-

-

... More
First Floor

21.48

-

-

... More
Providing and laying ceramic tiles having size 30 cm. x 30 cm. for dado and skirting in required position with readymade adhesive mortar of approved quality on plaster of 1:2 cement mortar including joint filling with white/ colour cement slurry cleaning curing etc. complete. S.S.R.2021-22 Item No. 33.25

45.78

-

-

... More
First Floor

101.64

-

-

... More
Providing and fixing in position Gypsum board false ceiling with 12.5 milimetre thick Gypsum boards, screwed/ fixed to the under structure of suspended galvanised iron Grid constructed and suspended from the main ceiling consisting of ceiling sections of size 25 x 50 milimetre maximum center to center distance of 600 milimetre perimeter channel and intermediate channels at maximum center to center distance 1200 milimetre galvanized grid should be fixed to reinforced cement concrete slab. The gypsum board should be fixed to galvanized iron grid with necessary screws. The boards should be taped and filled from underside to give smooth, seamless ceiling. The rate should include necessary additional ceiling sections and intermediate channels. Additional intermediate channels should be fixed to strap hangers for additional support to prevent strapping at every 1200 milimetre item to be completed in all respect including necessary sleeves for ducts finishing of joints cut outs, painting including labour, material, lifts etc. all complete. S.S.R.2021-22 Item No. 38.51

-

-

-

... More
First Floor

279.15

-

-

... More
Providing water proof bedding for flooring of Bath and WC 25 mm thick in C.M. 1:3 including using approved water proofing compound in specified proportion as per manufacturers specifications for per bag of cement including leveling, curing and covering 10 years guarantee on court fee stamp paper of Rs.500/- including ponding test etc. complete. S.S.R.2021-22 Item No. 31.05

-

-

-

... More
First Floor

21.48

-

-

... More
Providing and fixing on walls /ceiling /floor 40 milimetre diameter CPVC pipe with necessary fittings, remaking good the demolished portion.Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. S.S.R.2021-22 Item No. 42.59

27

-

-

... More
First Floor

250

-

-

... More
Providing and fixing on walls /ceiling /floor 15 milimetre diameter CPVC pipe with necessary fittings, remaking good the demolished portion. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed complete. S.S.R.2021-22 Item No. 42.55

55

-

-

... More
First Floor

300

-

-

... More
Providing and fixing 15 mm diameter screw down bib/stop tap of brass including necessary socket union nut complete. S.S.R.2021-22 Item No. 41.40

4

-

-

... More
First Floor

2

-

-

... More
Providing and fixing screw down for 40 mm diameter wheeled stop tap of brass including necessary sockets/union nut complete. S.S.R.2021-22 Item No. 41.47

4

-

-

... More
First Floor

2

-

-

... More
Providing and fixing C.P. BIB cock with wall flange of approved make including necessary sockets/union nut etc. complete. S.S.R.2021-22 Item No. 42.83

-

-

-

... More
First Floor

4

-

-

... More
Providing and fixing European type wall-hung white water closet of approved make with push valve concealed type with cover plate 32mm size of approved make including soil pipe, vent pipe up to outside face of wall, 100 mm diameter G.I. plug bend inlet pipe all fittings, cutting and making good walls, floors etc. complete. S.S.R.2021-22 Item No. 42.86

3

-

-

... More
First Floor

4

-

-

... More
Providing & fixing 15 mm diameter PVC Aqua kraft type of approved make super jet spray with flange 2 in 1 faucet 1.50 metre long including all accessories etc. complete. S.S.R.2021-22 Item No. 43.39

3

-

-

... More
First Floor

4

-

-

... More
Providing and fixing coloured glazed earthenware Wash Hand Basin of 55 cm x 40 cm including cold water piller tap/cold and hot water piller tap brackets, rubber plugs and brass chain, stop tap and necessary pipe connection including P.V.C. waste pipe and trap up to the outside face of the wall. S.S.R.2021-22 Item No. 41.66

3

-

-

... More
First Floor

4

-

-

... More
Providing and fixing 10centimetre cast iron Nahani Trap includingcast iron grating ,bend and piece of cast iron pipe upto the outside face of the wall complete. S.S.R.2021-22 Item No. 41.80

-

-

-

... More
First Floor

6

-

-

... More
Providing and fixing 15 cm x 10 m salt glazed stoneware gully trap in cement concrete 1:4:8 out side the building including cast iron grating in the sink, connecting glazed stonewre pipe brick masonry chamber with cast iron lid and cast iron grating for the gully trap. S.S.R.2021-22 Item No. 42.02

-

-

-

... More
First Floor

2

-

-

... More
Providing & constructing Brick Masonry Inspection Chamber 60 cm x 45 cm with R.C.C. raft in B.C. soil area including cost of reinforcement, 1:2:4 cement concrete channels half round Glazed Stone Ware pipes, Brick Masonry, plastering from inside and airtight 75 mm thick R.C.C. cover medium duty 100 kilogram etc. complete. S.S.R.2021-22 Item No. 42.16

-

-

-

... More
First Floor

2

-

-

... More
Providing, laying & fixing P.V.C. pipe of 110 mm. diameter with fittings such as bends, tees, reducers, clamps etc. including necessary excavation, trench filling etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. S.S.R.2021-22 Item No. 42.28

79

-

-

... More
First Floor

200

-

-

... More
Providing and fixing H.D.P container Syntex or alike one piece moulded water tank made out of high density polythyler and built corrugated inclusive of delivery up to destination hoisting and fixing of accessories such as inlet, outlet overflow pipe inclusive of all tanks capacity between 1000 to 20000 liters. S.S.R.2021-22 Item No. 42.54

6000

-

-

... More
First Floor

4000

-

-

... More
Excavation for foundation in hard murum and boulders including removing the excavated material up to a distance 50 metres, beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting, dewatering etc. complete. (Lift upto 1.5 m) by Mechanical Means. S.S.R.2021-22 Item No. 21.10

104.28

-

-

... More
Providing and laying in situ cement concrete M-20 with tremix treatment for 100 mm. thickness for flooring with groove cutting of 4 mm. wide and 20 mm. deep with necessary refilling with bitumen etc. complete. S.S.R.2021-22 Item No. 33.30

702

-

-

... More
Providing and applying water proofing treatment using acrylic polymer modified cement based water proofing coating with fibre glass mesh mixing at the rate of powder to liquid (2:1) by weight covering 9 to 10 sqm /kg with two coats using Dr. Fixit or alike of chemicals for masonry and concrete surface by brush covering 7 years guarantee on Stamp Papers etc. complete. S.S.R.2021-22 Item No. 31.09

125.82

-

-

... More
Providing fine cement finish 1.5 mm. thick over green plaster surface including scaffolding curing etc. complete.

447

-

-

... More
Providing and fixing self supporting steel roofing system (Proflex) for a Godown or alike made up of structural grade steel sheet of 912 milimetre width ( tolerance + / - 2 milimetre ), moulded at site using mechanical press dies to the desired curve and shape to form 605 milimetre wide interlocking panels . The interlocking panels shall be pressed to close the seam forming water tight joints for a span of 21.30 metre having arch rise as 4.26 metre, arch length 25.13 metre.The base material made up of imported galvalume steel complying to ASTM A792 having base metal thickness of 1.00 milimetre ( tolerace + / - 0.02 milimetre ) with alloy coating AZ 150 and paint coating of regular modified polyster, top coat 25 micron and bottom coat 12 micron as per approved colour, including fixing hangers, clamps etc.as may be necessary of Proflex standard, including fixing sky light of 2 milimetre thick polycarbonate sheet of size 2 feet x 14 feet and turbo ventilator of 24 inch diametre to be installed at every 30 feet along the length of roof including finishing, testing and cleaning etc. complete. S.S.R.2021-22 Item No. 38.42

824.85

-

-

... More
Dismantling the R.C.C. work 1:2:4 and sorting out the materials such as steel etc. as directed and stacking them within the specified lead as directed. S.S.R.2021-22 Item No. 46.29

94.03

-

-

... More
Removing doors and windows with frames and stacking the materials as directed with all leads, lifts, complete. S.S.R.2021-22 Item No. 46.15

18

-

-

... More
Removing ventilators and small windows with frame and stacking the materials with all leads lifts, complete. S.S.R.2021-22 Item No. 46.16

4

-

-

... More
Removing cement tiles, or marble or polished shahabad floor or dado without bed concrete including stacking the materials as directed with all leads, lifts, complete. S.S.R.2021-22 Item No. 46.19

168.88

-

-

... More
Removing Water Closet Pan including disconnecting the sanitary and water supply connections, removing and breaking flooring and bed concrete around pan removing the same carefully and stacking the serviceable materials as and where directed including throwing the unserviceable materials out side etc. complete. S.S.R.2021-22 Item No. 46.41

2

-

-

... More
Providing and laying Vitrified MATT finish having decorative type of size 1000 millimeter x 1000 millimeter of 8 to 10 millimeter thickness (on a existing flooring) with bonding chemical and confirming to I.S. 15622-2006 (Group Bla) of approved make shade and pattern for flooring in required position laid on a bed of bonding chemical filling joints curing and cleaning etc. complete. S.S.R.2021-22 Item No. 33.61

88.55

-

-

... More
Providing and laying vitrified matt finish tiles for Skirting having size 590 mm. to 605 mm. x to 605 mm. of 8 to 10 mm thickness and confirming I.S. 15622-2006 (Group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and cleaning etc. complete. S.S.R.2021-22 Item No. 33.43

15.58

-

-

... More
Providing and laying Cast in situ/ Ready Mix cement concrete in M-25 of trap/ granite/ quartzite/ gneiss metal for R.C.C. Pardi of required thickness including centering, formwork, cover blocks, laying/ pumping, compacting, curing, finishing and rougheningthem if special finish is to be provided and curing complete, (Excluding reinforcement and structural steel) with fully automatic micro processor based PLC with SCADA enabled Reversible Drum Type mixer/ concrete Batch Mix plant (Pan mixer) etc. complete, with fine aggregate (Crushed sand V.S.I. Grade) S.S.R.2021-22 Item No. 26.19.

115.86

-

-

... More
Providing and fixing black kadappa stone as shelves 25 mm. thick machine polished, extending the polish upto 20 cm. width on lowerside, rounding corners, laying in position jointing with bedding cement mortar 1:4 proportion curing etc. complete. S.S.R.2021-22 Item No. 33.23

1.8

-

-

... More
Providing earth work in embankment with approved materials obtained from other sources upto lead of 50 metre including all lifts, laying in layers of 20 centimetre to 30 centimetre thickness breaking clods, dressing to the required lines, curves, grades and section, watering and compaction with vibratory roller with V-Sat attachment to achieve not less than 97% of standard proctor density etc. complete (Material obtained from Other sources). S.S.R.2021-22 Item No. 2.28

1428

-

-

... More
Providing and errecting chain link fencing 1.6 metre height with galvanised iron chain link of size 50 x 50 milimetre 8 guage thick and fixed 75 milimetre above Ground level on vertical Mild Steel Angle of 40x40x6 milimetre size including excavating pits for foundation and embeded in cement concrete block of 1:4:8 mix of size 450x450x670 milimetre at 1.75 metre center to center with iron bar 16 milimetre diameter as hold fast including welding link with angle frame at 30 cm. c/c nuts and bolts and horizontal Mild Steel Angles at top and bottom of 25x25x5 metre size and vertical Mild Steel flat 35 x 5 metre and 25 x 5 metre horizontal including cross support of 40x40x6 metre Angles both sides at every corner or bends embeded in concrete blocks of 1:4:8 of size 450x450x670 milimetre including 3 coats of oil painting etc. complete. S.S.R.2021-22 Item No. 46.39

85

-

-

... More
Providing and laying Weep Holes of 100 mm diameter AC/ PVC pipes as per drawing for abutment returns, return walls etc. Complete. S.S.R.2021-22 Item No. 17.37

70.83

-

-

... More
Carting of excavated earth from site up to 2 km distance as directed by Architect S.S.R.2021-22 Item No. 2.28

1428

-

-

... More
Excavation for foundation in Hard murum including removing the excavated material upto a distance of 50 metres beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting, dewatering etc. complete. (Lift from 1.5 to 3.0 m.) by Mechanical Means. S.S.R.2021-22 Item No. 21.08

850

-

-

... More
Filling in plinth and floors with approved excavated material in 15cm.to 20cm. layers including watering and compacting etc. complete. Spec. No Bd.A.10 Page No. 262 (S. S. R. I. No. 21.36 & P. No. 191)

179.24

-

-

... More
Providing and laying Cast in situ/Ready Mix cement concrete in M-10 of trap / granite / quartzite / gneiss metal for foundation and bedding including bailing out water, Steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing if required and curing complete, with fully automatic micro processor based PLC with SCADA enabled reversibleDrum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) ) Spec. No. Bd. E. 1 Page No287, (S. S. R. I. No. 24.01 & P. No. 226)

28.88

-

-

... More
Providing Internal Cement Plaster 12mm Thick In Single Coat In Cement Mortar 1:4 Without Neeru Finish to concrete or brick surfaces, in all position including scaffolding and curing etc. complet. Spec. No. Bd.L. 2 Page No. 368 (S. S. R. I. No. 32.04 & Page No. 268)

360.64

-

-

... More
Providing and constructing Brick Masonry Inspection Chamber 60cm x 45cm x 90cm including 1:4:8 cement concrete foundation 1:2:4 cement concrete channels half round G.S.W. pipes, Brick Masonry, plastering from inside and with frame fixed in cement concrete with R.C.C. Cover medium duty 140 kg with frame etc complete. Spec. No. Bd.V.43 Page No.574. (S. S. R. I. No. 42.17 & Page No. 353 )

15

-

-

... More
Providing and fabricating structural steel work in rolled sections like joists, channels, angles, tees etc. as per detailed design and drawings or as directed including cutting, fabricating, hoisting, erecting, fixing in position making riveted / bolted /welded connections without connecting plates, braces etc. and including one coat of anticorrosive paint and over it two coats of oil painting of approved quality and shade etc. complete. Spec. No. Bd.C.2 Page No. 275 , (S. S. R. I. No. 23.01 & Page No. 223 )

0.67

-

-

... More
Providing and laying concrete pipes of I.S. NP. class of 150mm diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete.. Spec. No. Bd.V.41, Page No. 573 (S. S. R. I. No. 42.07 & Page No. 351)

54.2

-

-

... More
RWH - Shallow Percolation Pit providing, constructing 2.0m deep shallow depth percolation pit comprising of 1.0m dia pre-cast RCC rings, 300mm thick side filling around outside of RCC rings (annular space) with 40mm size boulders including filling of percolation pit up to 0.5m depth (from bottom up) with 25-75mm clean washed gravels followed by 0.5m depth of 10-25mm of clean washed stones followed by 0.5m of washed river fine aggregate (natural sand/crushed sand VSI grade finely washed etc.) including netlon mesh between each gravel/fine aggregate (natural sand/crushed sand VSI grade finely washed etc.) media layer including covering with RCC slab, manhole frame & cover, PVC rungs etc. including arrangement for inlet & outlet pipe, excavation & backfilling as shown in the drawing. The rate shall be inclusive of all labour, material, wastage, scaffolding, transportation, taxes, including all leads, lifts at all levels. All material should be of approved make. All works complete as per the drawing, technical specification and direction of the Engineer in charge (S. S. R. I. No. 48.46 & Page No. 405)

3

-

-

... More
Providing and fixing P.V.C. Rain water pipes of 160mm outer diameter and having wall thickness of 2.2 to 2.7 mm confirming to I.S. 13592-1992 including proper rainwater receiving recess with P.V.C. plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25mm to 40mm from face of wall a fixing with clips of approved quality and number ,filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on C.C. or masonry blocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All the P.V.C. fittings and additional 2 piece socket clips shall be got approved from engineer in charge etc. complete. (S. S. R. I. No. 42.85 & Page No. 355)

80

-

-

... More
Providing and fixing P.V.C. Rain water pipes of 110mm outer diameter and having wall thickness of 2.2 to 2.7 mm confirming to I.S. 13592-1992 including proper rainwater receiving recess with P.V.C. plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25mm to 40mm from face of wall a fixing with clips of approved quality and number ,filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on C.C. or masonry blocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All the P.V.C. fittings and additional 2 piece socket clips shall be got approved from engineer in charge etc. complete. (S. S. R. I. No. 42.87 & Page No. 355)

77

-

-

... More
RWH - Recharge Pit Providing and constructing recharge pit of 2.0m deep and 1.0m dia of pre-cast RCC rings with 6.5"diax25m deep bore well at the floor of recharge pit including installation of combination of solid/perforated PVC casing pipe wrappe d around with netlon mesh including 300mm thick side filling around out side of RCC rings (annular space)with 40 mm size boulders including filling of recharge pit up to 0.5m depth with 25-75mm clean washed gravels from bottom up followed by 0.5m depth of 10-25mm of clean washed stones followed by 0.5m of washed river fineaggregate (naturalsand/crushedsandVSIgradefinelywashed etc.) including netlon mesh between each gravel /fineaggregate (naturalsand/crushedsandVSIgradefinelywashed etc.) medialayer including covering with RCC slab, manhole frame & cover, PVC rungs, PVC end-caps, fittings etc. including arrangement forinlet & outlet pipe excavation & back filling as shown in the drawing. The rate shall be inclusive of all labour, material, wastage,scaffolding,transportation,taxes, including all leads, lifts at all levels. All material should be of approved make. All works complete as per the drawing ,technical specification and direction of the Engineer in charge.

1

-

-

... More
Boring/drilling bore well of 300mm dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machinery required for the job, all complete as per direction of Engineer in charge, upto 90m depth below ground level.

63.25

-

-

... More
Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well-casing pipe of 150mm dia, conforming to IS:12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per the direction of Engineer in charge. (S. S. R. I. No. 48.49 & Page No. )

65

-

-

... More
Excavation for foundation in earth, soils of all types, sand, gravel and soft murum, including removing the excavated material upto a distance of 50 m. beyond the building area and stacking or spreading as directed, preparing the bed for the foundation and necessary back filling, ramming, watering, including shoring and strutting as necessary complete. Lift 1.5 M to 3.0 M depth

8.73

-

-

... More
Providing and laying Cast in situ/Ready Mix cement concrete in M-15 of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including bailing out water, Steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing if required and curing complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand V

1.35

-

-

... More
Providing and applying washable oil bound distemper of approved colour and shade to old and new surfaces in two coats including scaffolding, preparing the surfaces (excluding the primer coat) complete.

24.21

-

-

... More
Providing and fixing chicken mesh of 22 gauge, with about 30 cm. width at the junction of R.C.C members and brick work, of approved quality including fixing mesh in position by necessary drilling in concrete /B.B.masonry and or tying by binding wire etc. complete. (S.S.R.2018-19 Item No 32.26 additional spec no. As directed by Engineer in Charge:

23.29

-

-

... More
Providing and applying Two coats of wall care Putty on plastered surface and Ceiling and Walls to prepare surface even and smooth of approved make, etc complete.

13.68

-

-

... More
Providing and laying chequered tiles ofapproved qualityof size 30cmx30cm, confirming to corresponding I.S.forflooring in required position laid on a bed of1:4 cement mortar including cement float,filling joint with cement slurry cleaning curing etc. compl

8

-

-

... More
Providing and laying vitrified mirror/glossy finish tile s having size 590mmto605mmx590mm to 605mm of 8to10mm thickness and confirming to IS.15622-2006 (groupBla) of approved make,shade and pattern fordadoandskirting inrequired position fixed in 1:4 cemen

22.36

-

-

... More
Providing and fixing green marble of 18 to 20 mm thick for doorframe/ dado/ window boxing etc. On C.M. 1:6 including filling joints with polymer base filler nosing / moulding the sharp edges wherever necessary, curing, etc. complete.

1.86

-

-

... More
Providing and Fixing 30MM thick BOTH SIDE PRELAMINATED SOLID PANEL PVC DOOR SHUTTER consisting of frame made out of M.S tubes of 19 guage thickness and, size19x19mm for styles and15x15mm for the top and bottom rails, M.S frames hall have acoatofmetelprimer of approved make and manufacture. M.S frame shall be covered withheatmouledPVC'C'channelmadefrom 5mm (+/0.25)thick prelaminated sheet of density 600kg/cbm, ofsize30mm thickness 70mm widthout of which 50mm shall be flat and 20mm shall be tapered in 45? angle on either side for mingstiles;and 5mm thick,95 mm wide PVCsheet out of which 75mm shall be faltand 20mm shall be tapered in 45 on the inner side to form top and bottom railand 115mm wide PVC sheet out of which 75mm shall be faltand 20mm shall be tapered on both sides toform lockrail.Top, bottom and lockrailshall be provide deithersideofthepanel.Anadditional5mm(+/0.25)thickPVCstripof20mmwidthistobestuckonthebottomsideofthe'c'channelprelaminatedpanelingof5mm(+/0.25)thickPVCsheettobefittedinsidetheM.S.framewelded/sealedtothestylesandrailswith5mm(+/0.25)x30mmPVCsheetbeadingoneithersideandjoinedtogetherwithsolventcementadhesiveetc,10mmthickness(5mm(+/0.25)x2nos)20mmwidecrossPVCsheetasgapinsertfortherailandbottomrail.Doortobefixedtoframeswith3nosM.S.powdercoatedbuthingesofsize100mmx25MMx2mmusing32mmlongsteelscrewsdrilledsuitabletopassthroughboththewallsoftheM.Stube.Otherhardwaresshouldbefixedwith19x6mmsizesteelscrewsincludingfixturefasting.Complete as per direction of engineer in charge.

1.58

-

-

... More
Providing and fixing 450mmx550mm size superior type Belgium mirror with 16mm dia. nickel plated towel rod etc. complete.

1

-

-

... More
Providing and fixing 900mm high S.S.304 Grade Stainless steel railing with 40mm diameter and 1.5mm thick at top, 40mm diameter and 1.5mm thick vertical supports spacedat 1.5 mcenter to center and 8mm thick toughened glass including fabricating, fixtures, errecting, necessary welding, grinding ,finishing,buffing to stainless steelpipeetc. complete

18

-

-

... More
Providing and fixing C.P. Angular stop clock with wall flange of approved make continental including necessary sockets / union nut etc. complete. Spec. No. As Directed By Engineer In Charge.

1

-

-

... More
Providing and fixing on Walls / Ceiling / Floor 25 mm Dia. CPVC Pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Spec. No. BD.V 5 page 551 and as directed by Engineer in charge

4

-

-

... More
Providing and fixing on Walls / Ceiling / Floor 32 mm Dia. CPVC Pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Spec. No. BD.V 5 page 551 and as directed by Engineer in charge

2

-

-

... More
Providing and fixing on Walls / Ceiling / Floor 50 mm Dia. CPVC Pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Spec. No. BD.V 5 page 551 and as directed by Engineer in charge

8

-

-

... More
Providing and fixing 15 mm. dia Ball cock medium type with PVC float including sockets and necessary fittings and tested as per municipal requirements etc. complete. Spec. No. As Directed By Engineer In Charge.

15

-

-

... More
Providing and fixing 40 mm. dia Ball cock medium type with PVC float including sockets and necessary fittings and tested as per municipal requirements etc. complete. Spec. No. As Directed By Engineer In Charge.

1

-

-

... More
Providing and constructing Brick Masonry Inspection Chamber 90cm x 45cm x 90cm including 1:4:8 cement concrete foundation 1:2:4 cement concrete chanels half round G.S.W.pipes, Brick Masonry, plastering from inside and C.I. lid cover of 75 kg with lid and frame fixed in cement concrete

1

-

-

... More
Providing , laying and fixing ,jointing Eco- drain 200 mm SN 4 Nu-Drain Upvc pipes or of equivalent make, manufacture as per EN 13476 or equivalent as per I.S.15328 with fittings such a bends, tees tees, coupler etc, jointing with rubber lubricant including necessary excavation, trench refilling with selective excavated materialetc.complete.

10

-

-

... More
Executive's Table @ 1800Lx900Dx750HT Providing & Fixing of Table @1800Lx900Dx750HT-TOP & GABLE END to be made of Membrane finish with softwater fall edges & curved panel & Decorated Anodized section MODESTY PANEL to be made of 18 mm thick Prelaminated particle board with PVC edge band as per drawing P. No.301 Item No. 51.21

5

-

-

... More
Providing & Arrangemnt of High Back Chair tilt mechanism with multilocking, high density cusion on seat composite leather with metallic silver finish base and arms with P.U. castors gaslift for height adjustment., P. No.305 Item No. 51.41

1

-

-

... More
Providing & Arrangemnt of Mid Back chair, ECOCTS Mechanism, Fixed Armrest, Gaslift for Seat height adjustment, Standard 5-prongP/Nylon Base with Fabric Upholstery., P. No.305 Item No. 51.43

100

-

-

... More
Providing & Fixing Curviliner Workstation @1500/1500Lx600/600Dx750HT, Curvilinear Table Top @1500/1500Lx600/600D:-TOP to be made of 25mm thick Prelaminated particle board with PVC edge band, GABLEEND tobe made of 25mm thick Prelaminated particle board with PVC edgeband, KEYBOARD TRAY (WITH OUT MOUSE TRAY):-Metal Powder Coated-Black Color, CPU TROLLEY:- Metal Powder Coated-Black Color, along with 3 DRAWER PEDESTAL UNIT having overall size 392Lx450Dx680Ht.mm. with central lock and key. 3 Drawers and body are complete metal with powder coat finish, facia in 18mm prelaminated particle board. P. No.303 Item No. 51.30

2

-

-

... More
Free Standing Table @ 1500Lx600Dx750HT Providing and fixing Table of Size 1500x600x750mm. Top:made from 25mm Prelaminated Particle board. All edges are covered by 2mm. Thk. PVC edge bands glued by hotmelt glue applied by auto edge banding machine. Legs: C Shape made from CRCA Sheet with Powder Coat finish. Modesty panel: Made from 18mm both side prelaminated particle boards. All edges are covered by 0.8mm PVC edge bands glued by hotmelt glue applied by auto edge banding machine. KEYBOARD TRAY (WITH OUT MOUSE TRAY):-Metal Powder Coated-Black Color,CPU TROLLEY:- Metal Powder Coated-Black Color, 3 DRAWER PEDESTAL UNIT having overall size 392Lx450Dx680Ht. mm. with central lock and key. Drawers and body are complete metal with powder coat finish, facia in 18 mm prelaminated particle board, P. No.302 Item No. 51.26

1

-

-

... More
Conference Table @ 1800 x 900 x 750 mm Ht. Providing & Fixing of MainTable @1800Lx900Dx750HT- made up of 18+18mm Thick MDF top with PVC Membrane finish and water fall edge profile. Aluminium Anodizied finish beeding of 4mm thick is running all over the table top edge. Gable ends is Aerofoiled Shape with front edges in PVC Membrane finish and rest in Prelaminated MDF with batton structure. Gable ends should be hollow from in side for the provision of passing electrical and Datawiring., MODESTY PANEL:- to be made of 18mm thick Prelaminated particle board with PVC edge band. Access Flap:- For Wire manager 1 Nos. P. No.304 Item No. 51.32

1

-

-

... More
Medium Height Steel Storage @ 750Lx450Dx1200HT Providing and fixing Openable Steel Storage of 750x450x1200Ht, with 2 adjustable shelves, Complete body & shutter made in 0.8mm thick & Top in 2mm thick CRCA, 2 Shutter to be mounted with the help of cup hinges, and 4 adjustable levelers, enitre storage in powder coated finish with 60 to 80 microns. with 25 mm. thk. as per drawing. P. No.304 Item No. 51.36

1

-

-

... More
Garden soils :- Supplying one side fresh garden soil well sieved 90% to pass through IS sieve of 10 mm size free from stone rubbish like dried grass root & other such materials the soil should be fresh from quarry. The colour of the soil generally be red. The soil will be measured by measuring box. (Item include Royalty charges. Corporation types transporting loading Unloading etc. complete. Horticulture DSR 1/2

3.75

-

-

... More
Suplying & laying well quality of manuar required for small, large tress including mixing with soil , watering, transportation at site etc. completed Horticulture DSR 2/2

3.75

-

-

... More
Saplings of flowering/shadytrces Gulmohar, Raintree, Peltophorum etc (one year old) Horticulture DSR 8/3

25

-

-

... More
Saplings of Small & medium Ornamental flowering plants , Thuja,Cupresus plants ornamental Ficus, Mussanda etc. Horticulture DSR 9/3

60

-

-

... More
Rose Plant :- Excavating pit with size 0.3x0.3x0.3 meter removing & conveying unwanted stuff of a required distance as directed filling the fresh garden soil in minor in 3:1 proportion to a required height of 0.3 meter mixing the soil & minor levelling, watering on previous night. Planting 40 to 50 cm height healthy plant of required rose verity mainaining till well established by watering weeding, sturring,prunning, replacing the casualities etc. complete. Horticulture DSR 9/5

20

-

-

... More
Mogra Plant/Creepers/Climbers:- Excavating pit with size 0.3x0.3x0.3 meter removing & conveying unwanted stuff of a required distance as directed filling the pit upto excavated material upto a height 15 cm. & ramming height of 15 cm. with fresh garden soil in minor in 3:1 proportion mixing the soil & minor levelling, watering on previous night. Planting (one year old) healthy plant as per specification mainaining till well established by watering weeding, sturring,prunning, replacing the casualities etc. complete. Horticulture DSR 10/6

20

-

-

... More
Planting large flowering/shady trees:- Digging pit with size 0.9 x 0.9 x 0.9 meter. Removing & conveying unwanted stuff of a required distance as directed filling the pit upto excavated material upto a height 30 cm. & ramming height of 60 cm. with fresh garden soil in minor in 3:1 proportion mixing the soil & minor levelling, watering on previous night. Planting (one year old) healthy trees sapling as per specification mainaining till well established by watering weeding, sturring of soil replacing of casualities etc. complete. Horticulture DSR 12/6

20

-

-

... More
Planting small & medium size ornamental flowering plant:-Digging pit with size 0.6 x 0.6 x 0.6 meter. Removing & conveying unwanted stuff of a required distance as directed filling the pit with fresh garden soil & farm yard minor upto a height of 0.6 meter in 3:1 proportion mixing the soil & minor levelling, watering on previous night. Planting (one year or two year old) healthy plant sapling as per specification mainaining till well established by watering, weeding, sturring of soil replacing of casualities etc. complete. Horticulture DSR 11/6

20

-

-

... More
Preparing instant Lawn :- Excavating the ground to a required depth of 20 cm. removing & conveying unwanted stuff to a required distance as directed filling fresh garden soil in minor in 3:1 proportion to a height of 20 cm. mixing soil & minor throughly well levelling with required slope light watering on previous night, rolling on surface. Fixed readymade lawn truf rolls or slab of reqired verity as directed. ramming on it for proper fixing & mainaining till well establish by watering, weeding, clipping or moving etc. complete. Horticulture DSR 3/4

6.25

-

-

... More
Preparing Edging or border:- Excavating the ground to a required depth of 20 cm. removing & conveying unwanted stuff to a required distance as directed filling fresh garden soil in minor in 3:1 proportion to a required height of 20 cm. mixing , levelling , watering the same planting suitable verity of edging plants & rooted cutting at distance of 15 cm. between plants to plants and row to row watering & maintaining till well grown to te stage of prunning Horticulture DSR 4/4

15

-

-

... More
Preparing Shrubbery:- Excavating the ground to a required depth of 30 cm. removing & conveying unwanted stuff to a required distance as directed. Providing and filling fresh garden required distance as directed. Providing and filling fresh garden soil and manure in excavated area in 3:1 proportion to a required height of 30 cm. Mixing , levelling , watering on previous night. Planting well rooted shrubs 0.5 mtrs. apart as directed and maintaining till well established by watering, weeding, strring replacing of casualties etc. complete. Horticulture DSR 8/5

7.5

-

-

... More
Dustbin 240 Litre Blue WB-240 Dimensions : 725 x 580 x 1075 mm ( 107x72x58cm ) Heavy Duty Sunproof Waste Garbage Bins Wheeled Bins Easy to maintain & Use Envirnoment Friendly Long Lasting Capacity : 240 Litre (Non SSR)

5

-

-

... More
Excavation for foundation in Soft rock and old cement or lime masonry foundations including removing the excavated material upto a distance of 50 metres beyond the building area and stacking as directed, including dewatering, preparing the bed for the foundation and necessary back filling with available earth /murum, ramming, watering including shoring and strutting etc. complete (lift upto 1.5m) By Mechanical Means, S. S. R. I. No. 21.14 & P. No. 188

6.76

-

-

... More
Disposing of dismantling materials of R.C.C. stone/ brick masonry / derbies, excavated material etc from work site beyond the 5 km Spec. No.:As directed by Engineer in charge etc. complete. (Beed District D.S.R, Page No. 125, Sr. No. 486)

171.37

-

-

... More
Providing and fixing in position,Double shuttered aluminium extruded powder coated openable door of specified size with aluminium doorframe of powder coated section101.60x44.75m,3.18mmthik and shutter comprising of powder coated section having bottom and lock railofsize150mmx44.5mmx3.00mmthicktoprails47.62x44.45mmx.00mmthick,verticalstyle47.62x44.45mm,3.00mmthickandforshutterplainglasspanes5mmthickfortoppanelsand12mmthickbothsidelaminatedphenolbondedparticleboardpanelsforbottopanelsetc.,I.S.I.mark,heavyduty,Hydraulicfloorspringof150kgcapacity,havingheavydutyconcealedlock,necessarybeading,glazingclips,PVCgaskets,250mmlengthaluminiumtowerbolts,150mmdia.padhandle,etc.asperdetaileddesignanddrawingorasdirectedbyengineerinchargeincludingallmaterials,labours,and equipment etc.complete

27.45

-

-

... More
Providing and fixing factory made solid core flush door shutters in double leaves 35mm thick,decorative type of exterior grade, as per detailed drawings, conforming to I.S.: 2202 – 1966 (Revised) including approved face veneers on both sides, without glazing and venetians including mat finish stainless steel fixtures and fastening, stoppers and finishing with french polishing etc. (Excluding door frame)(Sample to be got approved from Ex. Engineer before use) Commercial Hard Wood shutter

7.2

-

-

... More
Providngandfixinginpositionanodisedextrudedaluminumpartitions,partlyglazedandpartlylaminatedhavingframemadeoutofextrudedtubularsectionofsize40mmx60mmwith12mmthickthreelayeredflatpressedteakwoodparticleboardbondedwithBWPtypeexteriorgradephenolformaldehydesyntheticresinconformingtoIS128231990,laminatedonbothsides,Novateakorequivalentand5mmthickselectedqualityplain/floatglasspanelsfixedwithaluminumglassclips12mmx12mmandrubbercushioningbeadingto glass partitions as per approved drawing etc. compete

89.76

-

-

... More
Medium Height Partition @ 1800/1200HTTILEBASEDPARTITIONSYSTEM:-TilebasedAluminumpartitionsystemof1800/1200mmht.madeof60mmthkaluminumframeshavingtwoseparateracewaysforlayingelectrical&computerwiring.Thewiremanagementshallbethroughtotheracewaytobefittedatbottomofpartitionandotherimmediatelybelowofworktopwithhookontyperacewaycoverforeasyaccessofwires.FramestobejoinedbyaluminumconnectorswithM6x16pan-headmachinscrewandwasherwithaluminumpostcover.Postcoverofsnaponfashiontobeconnectedonaluminumconnectors.Allvisiblealuminiumtobeinanodizedfinish.Thetop/exposedsidesoftheframeandpostsshouldbecoveredwithhorizontal/VerticaltrimandcapsmadeofAluminuminanodizedfinishinordertoenhanceitslook.UppertilesofpartitiontobeinSoftBoardorMarkertileof9mm.thk.,andprelaminatedparticalboardlowertilesinlaminatefinishof9mm.thk.on both the sides.

18

-

-

... More
Multiple Compartment Lockers @ 1140Lx 457D x 1830 mm. Ht.Providing and fixing Multiple Compartment Lockers @1140Lx457Dx1830mm. Ht.with12 Compartments ,Completebody & shutter made of CRCA Sheet with powder coated finish as per approved color.

2

-

-

... More
Inspection kit

1

-

-

... More
Providing &Arrangemnt of MIdBack,Normal Syncro Mechanism,FixedArmrest,Gas lift for Seat height adjustment,Standard5-prong/Nylon Base with Leather Upholstery

8

-

-

... More
Foot operated sink units with sope dispensor single person use Size: 400x380x845mm + 2% Material: SS 304 Bowl Shape: Round Feature: Without Faucet No. of holes: One Thkness: Minimum 1.0 mm Splash Back Height: 45 mm + 10% Surface Treatment: Brushed Sink Style: Single Bowl Finish: Mirror Polished

2

-

-

... More
Hand Sanitizer Dispensor (Automatic/Hands Free) -Easy touchless operation with on and off button -Chrome and black with clear liquid chamber that stores up to 16.5 ounces of liquid content including soap or hand sanitizer -Amount of liquid dispensed can be adjusted -Touchless dispenser should sit on the countertop or mount to the wall -AA batteries operated for operating touchless dispenser

4

-

-

... More
Hand dryer -Material: ABS Plastic -Power: 2200 watts -Water Splash Proof: IP X 1 -Voltage: 220 V -Frequency: 50Hz-60Hz -Air Speed: 16M/S -7-12s fast drying hands

3

-

-

... More
Supplying standard first aid box with necessary antiseptic cream, medicine for use on wounds due burn, crepe bandage, gauge bandage, medicated ready to use bandage (Band-aid) adhesive tape for medicinal use, scissors, anti-septic solution (Savlon or similar) etc. (All above contents shall be of standard makes). 10-2-27

2

-

-

... More
Providing printed instruction chart

15

-

-

... More
Provided pair of duly tested rubber hand gloves as per IS :340715 suitable for working on 22kV supply. 10-2-23

4

-

-

... More
Inspection Tables with tubelights - M.O.C.: S.S. 304 - Length X Width: 1.2m X 0.76m x 0.76m - Support Str.: S.S. 304 -Thickness: minimum 2 mm; -Buffing: Mirror Finish - LED Tubelight 22 W to be fitted with SS structure -No. of legs: 6 made of 30 x 30 x 1.6 mm square tubes with rubber packing.

2

-

-

... More
Laboratory Equipments for pack house: A. EQUIPMENTS 1. Illuminated magnifier (Magnoscope) 20 X 2No* (Indian make) 2. Stereo binocular microscope with cold light source with 3MP camera 1No (Indian Make) 3. Inspection Table clear white top (steel make 2.5’X6’) 2 No* 4. Desktop Computer with internet 1No 5. Printer (24 Pin dot matrix) 1No 6. UPS for computer with sufficient power back up 1No B. INSPECTION KIT 1. Kit bag 1No.; 2. Knife (pointed) 2 No.; 3. Magnifier glass- 20 X with provision of light 2No.; 4. Camel brush 2No.; 5. Scissor 2No.; B146+B15. Torch with cell 2No.; 7. Forceps 2No.; 8. Marker pen- (Red & Black) 2No.; 9. Pencil &Sharpener 2No.; 10. Stapler With pin 1No.; 11. Cello tape- 1No.; 12. Rexene sheet- 1No.; 13. Marking slip- 50 No.; 14. Specimen vials - 20 No.; 15. Poly bags- 20No.; 16. Needle- 1No.; 17. Calculator- 1No.; 18. Hand Gloves- 30 pairs; 19. White enameled Tray (solid type) 4 Nos; 20. Apron 30 No.

1

-

-

... More
Weigh Balance (digital), 150 kg; ISI Marked Electronic Weighing Scale (Platform Scale) 1. Capacity: 150 kg 2. Accuracy: 20 g 3. Platter Size: 550 mm x 650 mm (Tolerance+/- 10 %), stainless steel made. 4. The body of the scale should be sturdy. 5. The Weighing Scale should have adequate Body Base Dimensions to maintain secure balance at the time of weighing. The Electronic weighing Scale (Platform Scale) should incorporate following features for user-friendly convenience: 1. Display: LED display with 5 digit, Size: Minimum height 14 mm 2. TARE function 3. The scale should have LED indications for A.C. On, Nett/Gross Weight, Zero, Battery, Battery Low. 4. The scale should have Memory Accumulation feature. 5. The Scale should have inbuilt rechargeable battery back up for minimum of 8 hrs. 6. Display Intensity should be adjustable, through keyboard, while operating on Battery for longer Battery back up. Make: Essae / Avery / Equivalent

3

-

-

... More
Weigh Balance (digital), 60 kg; ISI Marked Electronic Weighing Scale (Platform Scale) 1. Capacity: 60 kg 2. Accuracy: 2 g 3. Platter Size: 360 mm x 276 mm (Tolerance+/- 10 %), stainless steel made. 4. The body of the scale should be sturdy. 5. The Weighing Scale should have adequate Body Base Dimensions to maintain secure balance at the time of weighing. The Electronic weighing Scale (Platform Scale) should incorporate following features for user-friendly convenience: 1. Display: LED display with 5 digit, Size: Minimum height 14 mm 2. TARE function 3. The scale should have LED indications for A.C. On, Nett/Gross Weight, Zero, Battery, Battery Low. 4. The scale should have Memory Accumulation feature. 5. The Scale should have inbuilt rechargeable battery back up for minimum of 8 hrs. 6. Display Intensity should be adjustable, through keyboard, while operating on Battery for longer Battery back up. Make: Essae / Avery / Equivalent

3

-

-

... More
Weigh Balance (digital), 6 kg; ISI Marked Electronic Weighing Scale (Table Top) 1. Capacity: 6 kg 2. Accuracy: 1 g 3. Platter Size: 205 mm x 250 mm (Tolerance+/- 10 %), stainless steel made. 4. The body of the scale should be sturdy. 5. The Weighing Scale should have adequate Body Base Dimensions to maintain secure balance at the time of weighing. The Electronic weighing Scale (Table-Top) should incorporate following features for user-friendly convenience: 1. Display: LED display with 5 digit, Size: Minimum height 14 mm 2. TARE function 3. The scale should have LED indications for A.C. On, Nett/Gross Weight, Zero, Battery, Battery Low. 4. The scale should have Memory Accumulation feature. 5. The Scale should have inbuilt rechargeable battery back up for minimum of 8 hrs. 6. Display Intensity should be adjustable, through keyboard, while operating on Battery for longer Battery back up. Make: Essae / Avery / Equivalent

3

-

-

... More
Covid-19 Health and safety: Providing and making necessary arrangements of various essential materials and items of recommended quality and make as per guidelines of the health department required for prevention of COVID-19 pandemic in consideration of health and safety management of man power at construction site 1. Hand Sanitizer.: 50 liters 2. Disinfectant. : 30 Liters 3. Sodium Hypochlorite. : 30 KG 4. Fogging machine and Liquid for sanitization.: 1 Number 5. 3 Ply Face Mask of good quality. : 500 Numbers 6. Surgical / Latex Gloves of good quality.: 200 Pairs 7. Rubber Gloves of good quality.: 100 Pairs 8. Empty Spray Bottles 100 ml (Plastic).: 20 Numbers 9. Empty Spray Bottles 1000 ml (Plastic).: 5 Numbers 10. PPE kits. : 10 Numbers 10. Temperature Guns. : 3 Numbers 11. Face shield : 30 Numbers

1

-

-

... More
Electromechanical work

-

-

-

... More
PART-1: THERMAL INSULATION WORK

-

-

-

... More
INSULATED PANEL Supply and Erection as per General Technical Specifications , for walls-80 mm thick PIR panels,Density: 40 ±2kg /m3 0.5 mm thick Precoated G.S. Sheet (min. 180 GSM) on both sides with polyester coating (thickness: 20~25 micron)

30

-

-

... More
INSULATED PANEL Supply and Erection as per General Technical Specifications , for walls-100 mm thick PIR panels,Density: 40 ±2kg /m3 0.5 mm thick Precoated G.S. Sheet (min. 180 GSM) on both sides with polyester coating (thickness: 20~25 micron)

357

-

-

... More
INSULATED PANEL Supply and Erection as per General Technical Specifications, for ceiling-60 mm thick PIR panels, Density: 40 ±2kg /m3 0.5 mm thick Precoated G.S. Sheet (min. 180 GSM) on both sides with polyester coating (thickness: 20~25 micron) Ceiling support system including supports for hanging/fixing ceiling structure from the roof/slab level to be included. This structure shall be ensured to be with complete thermal break and should avoid metal connection between inside and outside.

76

-

-

... More
INSULATED PANEL Supply and Erection as per General Technical Specifications, for ceiling-100 mm thick PIR panels, Density: 40 ±2kg /m3 , 0.5 mm thick Precoated G.S. Sheet (min. 180 GSM) on both sides with polyester coating (thickness: 20~25 micron) Ceiling support system including supports for hanging/fixing ceiling structure from the roof/slab level to be included. This structure shall be ensured to be with complete thermal break and should avoid metal connection between inside and outside. Additional PIR filled hat section of minimum 50 mm thicnkess beyond any metal member of the support should be considered if only metal 'T' is being considered for ceiling panel support.

237

-

-

... More
INSULATED FLOOR Supply and Erection as per General Technical Specifications Floor 100 mm XPS , min 30 kg/cu.m density. Rate for floor insulation to include supply and erection of all ancilliaries including polythene vapour barrier & two ply tarfelt as per specifications and bituminous primer, bitumin / bituminous cold compound for proper adhesion to surfaces.

230

-

-

... More
Supply & Fixing of 6~9 mm thick EPDM / Nitrile rubber on RCC slab / brick walls with suitable CPRX compound adhesive over which the insulated panels shall be fixed tightly with Nylon / FRP / Steel reinforced Nylon bolts.The bolt heads on the panels shall be covered with hat runners filled with PUF insulation as per standard practice.

85

-

-

... More
Supply & fixing of of Al foil min. 50 micron on RCC slab / brick walls with suitable CPRX compound adhesive / bitumen

90

-

-

... More
Ancillary Materials and Services - Flashings for Internal and external wall-ceiling joints and wall-wall joints as applicable or as may be required for doors or other openings. The layout showing the chamber dimensions and height is enclosed for ready reference. The flashings should be atleast 50mm x 50 mm or larger sizes with adequate overlap over any given panel-panel joint (Precoated G.S. Sheet, minimum 0.5 mm thick)

1

-

-

... More
Ancillary Materials and Services - Silicon / Polyeurathene sealant for sealing the gaps between panels and the external / internal face of the insulation panels and any other location as may be deemed suitable for proper insulation panel erection system as applicable.

1

-

-

... More
Ancillary Materials and Services - PUF/PIR chemical, adhesives,/ tapes / plastic caps etc reqd for onsite application, as may be necessary for a complete and foolproof insulation job.

1

-

-

... More
Ancillary Materials and Services -SITC of Pressure relief ports suitable for mounting on insulated panels of various thicknesses (60 mm to 100 mm) with internal heaters for room temperatures ranging from 25 deg C to (-) 10 deg C. (Fermond Soupape 2220 -Valve /Equivalent)- 1 no for each cold storage chamber.

2

-

-

... More
Ancillary Materials and Services - Making & finishing of cut outs for doors, pipes, cables, pressure ports etc as per requirement at site. Finishing would include filling with PUF/PIR & PUF/PIR foam of required density and covering with pre - coated G.I.sheet from both side of the panels to give aesthetically neat joint acceptable to Consultants / Owners. This should also include any additional Silicon sealent or any other material as required.

1

-

-

... More
Precooling Chamber1,2, Staging cold room 1,2 Manual Sliding type 1500 mm x 2600 mm ht x 100 mm thick PIR , manual type Providing & fixing of Insulated sliding doors (suitable for fitting on panel structure) of clear opening size & insulation thicknesses as mentioned and specifications as per General technical specifications (GTS). The doors shall be manual single leaf sliding with 0.6 mm thick SS-304 sheet or pre-coated extruded Aluminium of required thickness main frame. The door leaf shall have 0.5 mm thick PCGI sheet with min 180 GSM galvanising / S.S sheet cladding on both sides with PIR foam filled In-situ and with a density 40 ± 2 Kg/m3 (insulation thicknesses as mentioned).0.60mm thick PCGI sheet flashing to protect and reinforce the cut out opening in panel wall to be included in the cost. The sliding mechanism should be sturdy and smooth in operation complete with rail, runners, sill on the bottom etc. Rail shall be made of heavy duty aluminium alloy / SS with 45º drop & with polyethylene roller / special grade nylon arrangement runner system. The rail shall be provided with canopy / cover of 1.2 mm thick PCGI / Extruded Aluminium of required thickness. The doors shall have easily replaceable EPDM gaskets to ensure perfect hermetic sealing .

4

-

-

... More
For Paaasage Area Insulated Doors -Swing type with double shutter 2000 mm x 2600 mm ht x 60 mm thick PIR Providing & fixing of Insulated doors (suitable for fitting on panel /brick wall structure) mounting of clear opening size & insulation thicknesses as mentioned and specifications as per General technical specifications (GTS). The doors shall be manually operated double leaf swing type with 1.25 mm thick SS-304 sheet or pre-coated extruded Aluminium of required thickness main frame.Any other material for door frame may be considered on case to case basis. The door leaf shall have 0.6 mm thick PCGI sheet with min 180 GSM galvanising / S.S sheet cladding on both sides with PIR foam filled In-situ and with a density 42 ± 2 Kg/m3 (insulation thicknesses as mentioned).Viewing window on each door leaf shall be provided. The rate shall include all minor accessories not specifically mentioned in the technical specification, but essential for the completeness of the work.

1

-

-

... More
DOCK DOOR & SHELTER Dock door shall be vertically moving with motorized movement. The shutter shall have PUF core with aluminum external / internal facing with white paint (RAL9003E/Eqvt). The vertical moving track shall be U shaped made of 2.5 mm G.S. Sheets. Full perimeters doors seal with PUF verticals, Vinyl lintel seal & rubber seal of bottom shall be provided. acceptable makes: Gandhi Automation/ Metaflex/Infraca/eqvt (a) Dock door motorised type (b) Dock door motorized complete with control control button, manual lock release & cabling. DOCK DOOR: Type:motorised type Door opening Size : 2400 width x 2700 mm height Insulation : 40 mm PUF Door Movement : upwards, then curving into the ceiling Facing : External : Aluminium painted white Internal : Paint for higher impactability Operator : Normal Viewing Window: 1 no DOCK SHELTER : Retractable type suitable for heavy duty operations for door opening size as above. Dock seal to have adjustable top vertical member so as to adjust for container height variations

1

-

-

... More
DOCK LEVELER Designed for Hydraulic operation as per General technical specification ,Acceptable makes: Gandhi Automation/ Metaflex/Infraca/eqvt Size : 2000mm width and 2500mm deep, lift height min 300 mm from centre level, upwards & downwards., main cylinders-2 nos, All controls, control panels, controllers, power and control cabling etc as required for full operation to be included

1

-

-

... More
SITC of strip curtains made of 3 mm thick transparent PVC sheet strips with 40 / 50 mm overlapping and supporting clamps. The strips shall have free swinging motion. The strip material shall be suitable for the specified low temperature application to ensure that it remains soft even at the lowest operating temperature

-

-

-

... More
Precooling Chamber 1,2, Staging cold room 1,2 Suitable for Clear opening Size: 1500mm X 2600mm ht

4

-

-

... More
For Passage Area Suitable for Clear opening Size: 2000mm X 2600mm ht

1

-

-

... More
For Ante-Room Area Suitable for Clear opening size: 2000 mm x 2100 mm ht

1

-

-

... More
PART-3: Refrigeration System for Pre-cooling chamber, Staging cold rooms, ante-room and Dock Area

-

-

-

... More
AIR COOLED CONDENSING UNITS For Pre-Cooling chamber 1,2 (General details as per PART – II - REFRIGERATION SYSTEM of GTS) Complete with Reputed approved make semi hermatic reciprocating compressor working on R449A / R448 A or other approved HFO, Air cooled condenser, Liquid receiver,Oil separator with check valve in discharge line, Base frame for mounting, H.P. / L.P.switches, Suction accumulator Vibration eliminator, Oil pr switch and pressure gauges , Sturdy MS Stand with two coats of primer and two coats of oil paint of approved colour etc. as required. Condenser coil to be designed for 10 deg C TD between ambient temperature and condensing temperature. Other Technical specifications as per General Technical specifications as mentioned in the tender. The capacity and other details shall be as follows : For Pre-Cooling chamber 1,2 ( 2 nos for each ACU): Capacity: 26 KW DesignTemperature: (-)4 deg. C evap. and +48 deg.C cond. Temp Maximum ambient Temperature: 42 deg C ambient Minimum fin spacing: 2 mm Condensing unit inlet air pre-cooling system: to be included There shall be provision to run each condensing unit separately especially in cases where product qty is low. Related controls (PLC if needed), cabling, control panel, etc shall be included in the cost. This shoud be possible in Automode as well as manual mode.

4

-

-

... More
AIR COOLED CONDENSING UNITS For staging cold room 1,2 (General details as per PART – II - REFRIGERATION SYSTEM of GTS) Complete with Reputed approved make semi hermatic reciprocating compressor working on R449A / R448 A or other approved HFO, Air cooled condenser, Liquid receiver,Oil separator with check valve in discharge line, Base frame for mounting, H.P. / L.P.switches, Suction accumulator Vibration eliminator, Oil pr switch and pressure gauges Condenser coil to be designed for 10 deg C TD between ambient temperature and condensing temperature. Other Technical specifications as per General Technical specifications as mentioned in the tender. The capacity and other details shall be as follows : For staging cold room 1,2 Capacity: 13 KW DesignTemperature: (-)4 deg. C evap. and +48 deg.C cond. Temp Maximum ambient Temperature: 42 deg C ambient Minimum fin spacing: 2 mm Condensing unit inlet air pre-cooling system: to be included

2

-

-

... More
AIR COOLED CONDENSING UNITS For Passage Area (General details as per PART – II - REFRIGERATION SYSTEM of GTS) Complete with Reputed approved make semi hermatic reciprocating compressor working on R513A / R450A or other approved HFO, Air cooled condenser, Liquid receiver, Base frame for mounting, H.P. / L.P. cut outs and pressure gauges etc. Sturdy MS Stand with two coats of primer and two coats of oil paint of approved colour etc. as required. Condenser coil to be designed for 10 deg C TD between ambient temperature and condensing temperature. Other Technical specifications as per General Technical specifications as mentioned in the tender. The capacity and other details shall be as follows : For Dock Area Capacity: 12.5 KW DesignTemperature: 10 deg. C evap. and +48 deg.C cond. Temp Maximum ambient Temperature: 42 deg C ambient Minimum fin spacing: 2 mm Condensing unit inlet air pre-cooling system: to be included

1

-

-

... More
AIR COOLING UNITS - Air Cooling Units for Pre-cooling chamber 1,2 (General details as per PART – II - REFRIGERATION SYSTEM of GTS) Technical specifications as per General Technical Specifications as mentioned in the tender. The capacity and other details shall be as follows : Make: Star coolers / GEA / Alfa Laval / Guentner / LU-VE / Thermofin / Eqvt, Model: To be Mentioned Type of Unit -Single / Twin: Twin coil type,Type of Refrigerant feed: HFO - DX Capacity - kW: 51, Evap. Temp. & TD ‘C’: (-)4 °C / 4 °C Coil / Fin MOC: Cu / Al, Fin spacing -mm: 6 mm Fin type: Plate, Finned coil length -m: To be Mentioned Total fan capacity of each unit– CMH: 52500, External sp. Wg, mm: 25 No of Fans/Unit: 3/4, Fan Motor -kW each: To be Mentioned Air throw -m: 8 m, Drain pan insulation: Required Drain pan heating: Not required Type of Defrosting: off cycle (provision to be kept for adding electrical defrost at later stage) Fan peripheral heating: Not required Suitable Supporting structure from primary support at roof level or mounting stand (if supporting from floor level) to be considered in the costing as well. Product Covering Flap - Suitable product covering flap made of PVC sheet / EQVT sturdy material to be mounted on the unit above the fan(s) to ensure proper air flow through the produce. There shall be suitable reinforcement inside the flap as well as at the ends for supporting the Flap. Costing for the same also shall be included. It must be noted that this scheme is considered as a part of a combined pre-cooling system which will have an airtight plenum created between the wall panel and the area around the ACU as defined above. So while the insulated panel will be billed as per the the insulation panel rates, the cutting for the panel, the flashings, etc as needed for the pre-cooling unit arrangement should be considered while quoting the cost of panels.

2

-

-

... More
AIR COOLING UNITS - Air Cooling Units for Staging cold room 1,2 (General details as per PART – II - REFRIGERATION SYSTEM of GTS) Technical specifications as per General Technical Specifications as mentioned in the tender. The capacity and other details shall be as follows : Make: Star coolers / GEA / Alfa Laval / Guentner / LU-VE / Thermofin / Eqvt, Model: To be Mentioned Type of Unit -Single / Twin: Single coil type Type of Refrigerant feed: HFO - DX Capacity - kW: 13 Evap. Temp. & TD ‘C’: (-)4 °C / 4 °C Coil / Fin MOC: Cu / Al Fin spacing -mm: 6 mm Fin type: Plate Finned coil length -m: To be Mentioned Total fan capacity of each unit– CMH: 15000 External sp. Wg, mm: 5 No of Fans/Unit: 2/3 Fan Motor -kW each: To be Mentioned Air throw -m: 8 m Drain pan insulation: Required Drain pan heating: Not required Type of Defrosting: Electrical Fan peripheral heating: Not required Suitable Supporting structure from primary support at roof level or mounting stand (if supporting from floor level) to be considered in the costing as well.

2

-

-

... More
AIR COOLING UNITS - Air Cooling Units for For Dock Area (General details as per PART – II - REFRIGERATION SYSTEM of GTS) Technical specifications as per General Technical Specifications as mentioned in the tender. The capacity and other details shall be as follows : Make: Star coolers / GEA / Alfa Laval / Guentner / LU-VE / Thermofin / Eqvt, Model: To be Mentioned Type of Unit -Single / Twin: Single coil type Type of Refrigerant feed: HFO - DX Capacity - kW: 12.5 Evap. Temp. & TD ‘C’: 10 °C / 10 °C Coil / Fin MOC: Cu / Al Fin spacing -mm: 4 mm Fin type: Plate Finned coil length -m: To be Mentioned Total fan capacity of each unit– CMH: 6600 External sp. Wg, mm: 7 No of Fans/Unit: 2/3 Fan Motor -kW each: To be Mentioned Air throw -m: 20 m Drain pan insulation: Required Drain pan heating: Not required Type of Defrosting: offcycle Fan peripheral heating: Not required Suitable Supporting structure from primary support at roof level to be considered in the costing as well.

1

-

-

... More
Refrigeration Piping, Fittings & Valves (General details as per PART – II- REFRIGERATION SYSTEM of GTS) The piping shall be of refrigeration quality The piping shall be of refrigeration quality seamless copper tubes and the valves shall be brassomatic / Henry or equivalent make. The piping shall be included accessories such as filter, drier, sight glass, heat exchanger, suction lineaccumulator etc. as per P & I diagram approved by Consultant. Adequate number of supports shall be included. The piping shall be supported at distances of maximum 1.5 m from each other with suitably placed GS threaded rods of minimum 6 mm thickness when outside the chamber and piping shall be run on cable trays of size suitable to fit the pipes including insulation. Common cable trays can be considered depending on the suitability at site, however the same shall be acceptable to the consultant / owner. Overall, the piping execution shall ensure proper workmanship and a neat and tidy work is expected with straight horizontal and vertical lines and proper supporting. Under no circumstances shall any additional charges be demanded by the contractor for ensuring the same. The suction and discharge lines shall be designed for a maximum pressure drop corresponding to 1.1 deg. C drop in saturated evaporating and condensing temperatures. The liquid line shall be designed for maximum pressure drop corresponding to a drop 0.5 to 1 deg. C in saturation temperature. The piping shall be designed with proper slope in the direction of Refrigerant flow and to ensure proper oil return to the compressor and should be installed with adequate supports to avoid undue vibration. The piping should be thoroughly cleaned as per standard practice prior to installation. Refrigeration piping,fittings,valves,interconnecting condensing & evaporator unit complete with standard controls & accessories, supports as may be required shall be included in cost.layout drawing showing proposed location of condesing units is atttached for your reference.

1

-

-

... More
Suction line insulation (General details as per PART – II- REFRIGERATION SYSTEM of GTS) Suction line insulation with EPDM/ XLPE/Equivalent insulation with minimum 28G Aluminium foil Clading in the covered areas and Weatherproof Clading in areas exposed to sunlight and is uncovered ; e.g. Woven glass cloth with epoxy coating or Armacheck GC+weatherproof coating/equivalent Clading with suitable fittings and Adhesives.Alternatively,Fevicol Weather protect coat applied as per manufacturers recommendation may be used for entire insulton protection. Thickness - 25mm Insulation supports shall be half round or full round heavy duty PVC pipe sections of relevant size which shall be atleast 150 mm in length and shall be placed below every support. This is essentially ensuring that the insulation compression at the support is at the minimum.

1

-

-

... More
Drain piping with rigid U-PVC pipe from A.C. units to to suitable drain point complete with 'U' Traps for each cold room and supports.Drain lines (inside the chambers) to have 10 mm EPDM / Eqvt. insulation with factory backed Aluminium foil.Individiual Drain outlet line from ACU pipe size shall be same as the drain outlet of ACU and further the header shall be at least one size higher than the drain outlet connection size. Further, higher sizes may be considered as per the consultants/owner's recommendation

1

-

-

... More
Controls and Instruments (a) Thermostatic expansion valves for each ACUs (b) Digital temperature indicator cum controllers (0 to 50 deg. C range) (c) Liquid line solenoid valves, DANFOSS / SPORLAN /EQVT make (d) Digital temperature indicator (minus 20 to 50 deg. C range), for A.C. units to be placed outside the each cold rooms in ante-room area. (e) Digital RH indicator (0 to 100 % range) for A.C. units to be placed outside the each cold rooms in ante-room area. Only for pre-cooling ,staging cold room ACUs

1

-

-

... More
First charge refrigeration gas and oil etc. as required upto commissioning and final handling over of plant.

1

-

-

... More
Painting of equipment/piping / piping supports etc. as per standard colour codes with initial coat of red oxide primer and two coats of synthetic enamel paint .

1

-

-

... More
Humidification system for pre-cooling chambers complete with Industrial type Ultrasonic Humidifier, U-PVC water piping from the tanks to humidifier unit, fitting ,valves, atomizer nozzles (if requird), solenoid valves with strainers and humidistats etc. as may be required to maintain the relative humidity in the design range for Pre-Cooling Chambers. Also consider heavy duty PVC piping for air delivery into the cooling area for a release of humidified air into the main air stream, at atleast 1 m distance from the partition panel Humidifier Capacity: 12 Lit/hr.

2

-

-

... More
Electrical work for Refrigeration System (General details as per PART – II A- REFRIGERATION SYSTEM of GTS) Electrical control panel shall be manufactured as per specifications menioned in GTS and approved GA drawings. The Panel shall be comprising of following: a) Suitable Incomer of ACB / MCCB / MCB / RCBO of required rating and as per enclosed specification and approval. b) All Suitable rating MCB's, MPCB's, RCBO's, starters, relays, etc for various motors as used in the equipments shall be selected as per type 2 co ordination chart provided by the manufacturer. c) MCBs for control circuit d) Each starter shall be provided with facility for remote Start/Stop operation. This panel shall be located in the plant room (on terrace level) and shal have weather proof enclosure with suitable MCB's/RCCB's/RCBO's near the condensing unit. Job includes Electrical Power cabling (armoured) to all the outgoing feeders along with PVC medium duty Conduit/ pregalvanised Cable tray's, etc as per requirement and power cabling shall be as per specifications given in GTS. Control wiring with PVC insulated copper conductor with conduits as required for the refrigeration and other systems as defined here. Local Protection through MCB's/RCCB's/RCBO's for A.C. units, fan motors and other remotely located motors shall be part of the job.The Job shall also include earthing for control panel and various motors etc. using required sizes earthing conductors using GI/Cu earthing strips or Cu Conductors, all as per IS.The control panel shall have provision for interlocking of various equipment as per standard practice.

1

-

-

... More
Miscellaneous Items a) Vibration isolators for condensing units, supporting rods / Frame for A.C. Units with insulation, steel structure for mouting condensing units etc. as may be required b) Minor structural openings in walls / panels etc for piping, cabling etc. and finishing. c) 2000 lit water tank along with water pump as necessary for lifting water to the tank or lifting water from the tank depending on tank location ,UPVC piping, fittings,valves etc as may be required for condenser inlet air-precooling system. Condenser air pre-cooling system shall have automatic operation with water line sonenoid valves for each individual condensing unit and there shall be an interlock with the conensing unit start/stop as well as the ambiend air temperature wherein the air precooling system starts only after the ambient air temperature crosses 33 deg C and switches off when ambient goes beloe 33 deg C.

1

-

-

... More
Charges for Installation, Testing and Commissioning Installation, testing and commissioning of all above equipment / material as per the system requirement. All tools and tackles, welding machines, welding rods and gases etc. required for fabrication, erection, testing and commissioning shall be arranged by the contractor at his cost. The plant shall be erected, tested, commissioned as per Consultant's approved drawings / specifications and instructions to his and Employer's satisfaction. The refrigeration system shall be pressure tested and evacuated as per standard practice before charging the refrigerant. The water lines shall also be pressure tested as per standard practice. The plant shall be run for a period of three days after commoissioning by the contractor, to assess the plant performance. The contractor shall provide 3 hard copies of operation & maintenance for the plant along with as built drawings. The contractor shall also arrange the training of the operating staff for proper operation & maintenance of the plant (included in above rates)

1

-

-

... More
PART-4:Electrification work

-

-

-

... More
Supply, Installation, Testing & Commissioning of earthing station using pipe in pipe earthing electrode with complete system as per specs. Including boring, civil work, chamber etc. Earthing shall be carried out as described in IS-3043-1960 code. Pipe in pipe earthing electrode system shall be as per enclosed technical specifications. The entire earthing system should be executed as per system supplier’s instructions. The Earthing Chamber with all the necessary material required for earthing shall be in Contractors scope. Testing of the Earthing system shall be as per specification & results shall be submitted to Engineer-in-Charge duly signed by contractor and authorized representative. 2 meters Length Earthing Electrode

2

-

-

... More
Same as above but electrode length shall be 3 mts.

2

-

-

... More
Supply & Installation of 32 x 6 mm Galvanized Iron earthing strip & Conductor shall be of High Conductivity. All Necessary Accessories required for installation of Earthing Strips such as Porcelain Insulators, Clamps, Saddles, Hardware, etc will be included in the rate. The Earthing strips connections shall be used as per the provided earthing schedule.

50

-

-

... More
Same as above with Earthing strip of 25 x 3 mm Copper.

60

-

-

... More
Supply & Installation of 6" dia RCC half round pipe for covering HT/LT cables. Rate shall be inclusive of excavation, back filling and civil work for chambers.

1

-

-

... More
Supply & Installation of 6" dia RCC round pipe for HT/LT XLPE cables laid for Road Crossing. Rate shall be inclusive of excavation, back filling and civil work for chambers.

1

-

-

... More
Supply & Installation of 146/150MM dia round HDPE Pipe for LT cables. Rate shall be inclusive of excavation, back filling and civil work for chambers.

1

-

-

... More
Supply & Installation of 50MM dia round HDPE Pipe for LT cables. Rate shall be inclusive of excavation, back filling and civil work for chambers.

1

-

-

... More
Liaisoning Work with Electricity board & Electrical inspector or any other government authority for change of sanction & Contract load as per new requirement of electrical load. Job involves preparation of necessary documents with drawings, as required for load application, submission of document files with necessary officials / departments, follow-up with all concerned departments for getting required load sanctioned. Obtaining work completion report from Electrical inspector & board officials. Client (Owner) will make all official payments as per the requirement of Electricity board.

1

-

-

... More
Supply & Installation of printed Danger Board/instruction chart for treating persons suffering from electric shock, printed in English & Marathi and duly laminated complete.

6

-

-

... More
Providing Round bottom fire bucket of 9 Litres capacity as per IS : 2546 made out of 24 gauge G.I. sheet with extra handle at bottom duly painted white inside and red outside with FIRE Mark, on provided stand/ wall hook complete

6

-

-

... More
Providing Floor mounting stand for keeping 4 Nos. of FIRE buckets 1500mm in length, 900mm in height frame made out of 30x30x4 mm angle iron with cross supports for legs, welded with 4 hooks and duly painted with one coat of red lead and two coats of silver paint complete.

1

-

-

... More
Supplying and erecting wall hook 225mm projection for keeping fire buckets made out of 15 mm dia. M.S. Rod grouted in wall to a depth of minimum 15cms complete.

2

-

-

... More
Providing pair of duly tested rubber hand gloves as per IS :47705 suitable for working upto 22 kV supply complete.

2

-

-

... More
Supplying standard first aid box with necessary antiseptic cream, medicine for use on wounds due burn, crepe bandage, gauge bandage, medicated ready to use bandage (Band-Aid) adhesive tape for medicinal use, scissors, anti-septic solution, etc. (All above contents shall be of standard makes)

2

-

-

... More
Supplying and fixing PVC synthetic elastomer electrically insulating mat with class A insulation conforming to IS: 15652 – 2006 & CPRI tested having 2 mm thickness upto 3.3 kV

5

-

-

... More
Supplying and erecting D.C.P. type fire extinguisher 6 kg capacity cartridge type with gun metal cap 150 gram CO2 gas cartridge, powder and brackets conforming to IS 2171-1985/ IS 15683 and complete erected with necessary clamps made from 50x6 mm M.S. flat with nuts & bolts grouted in wall complete.

5

-

-

... More
Supplying and erecting ABC powder type fire extinguisher as per IS : 13849 /15683 of 6 kg capacity with necessary clamp for erection on wall.

5

-

-

... More
Supply, Installation, Testing & Commissioning of outdoor type MCCB panel to be installed near transformer & comprising of following:- 315 Amp. 4 pole 36 KA MCCB with Microprocessor based LSIG protection, with rotary door handle, spreader links, phase barrier etc - 1 No. 96 sq.mm. 0-500 V digital voltmeter with built-in selector switch. - 1 No. 96 sq.mm. 0-300 Amp. digital ammeter with built-in selector switch & CTs. - 1 No. Indicating lamps LED type - 1 Lot. Control MCB - 1 Lot. Neutral Link - 1 Lot. Space heater with thermostat & MCB for protection - 1 No. 2 KVAr Fixed type APP/Gas capacitor banks - 1 No. having 6 Amp. TP 10 KA MCB, capacitor duty contactor suitable for 2 KVAr bank - 1 No., 1 KVAr Fixed type APP/Gas capacitor banks - 1 No. having 6 Amp. TP 10 KA MCB, capacitor duty contactor suitable for 1 KVAr bank - 1 No. 1 pole two way selector switch for capacitor Start/Stop action - 2 Nos, electronic timer, ON/OFF indication. This bank will remain on as long as EB supply is available. Ventilation Lovers with powder coated MS filters to be provided in panel. Notes: Panel shall be suitable for outdoor installation & having double door in the front side. Breaker operating parts & meters shall be accessible after opening of front door only. Front door will have a Acrylic window cutout, so that the Meters & Indications are visible. Panel shall be provided with angle frame of 500 mm height made from 50x5 M.S. angle and matching covers from three sides. Aluminium busbar of 300 Amp. @ 0.8 Amp / mm Current Density & 50 degree C ambient temperature.. Cable entry at bottom & shall be suitable for cable as mentioned in SLD.

1

-

-

... More
Supply, Installation, Testing & Commissioning of Main PCC made as per specifications and comprising of following:- Incoming:- 315 Amp. 4 pole 36 KA MCCB with Microprocessor based LSIG protection, with rotary door handle, spreader links, phase barrier etc - 2 Nos., 125 Amp. 4 pole 36 KA MCCB with Microprocessor based LSIG protection, with rotary door handle, spreader links, phase barrier etc - 1 No, 1 No., 96 sq.mm. 0-500 V digital voltmeter with built-in selector switch. 3Nos., 96 sq.mm. 0-300 Amp. digital ammeter with built-in selector switch & CTS. 2Nos., 96 sq.mm. 0-125 Amp. digital ammeter with built-in selector switch & CTS. 1No., 315 Amp. 4 pole Automatic Transfer Switch with NO/NC Contcts, Multi function energy meter 1.0 class with RS 485 communication port & CT's. 3 Nos., 300/5 Amp. class 1.0 CT for APFC relay input. 1 No., Phase indicating lamps. 1 Lot., MCCB ON/OFF/Trip indication. 1 Lot., Control fuses. 1 Lot., Neutral Link. 1 Lot., Emergency Stop Push Button. 1 Lot., 6 Amp. 4 pole 10 KA MCB. 2 Nos., 6 Amp. 2 pole 10 KA MCB. 3 Nos, Outgoing:- 250 Amp. 4 pole 36 KA MCCB with adjustable thermal, fix magnetic release, with rotary door handle, spreader links, phase barrier etc. 1 No.,125 Amp. 4 pole 36 KA MCCB with adjustable thermal, fix magnetic release, with rotary door handle, spreader links, phase barrier etc. 4 Nos., 63 Amp. 4 pole 36 KA MCCB with adjustable thermal, fix magnetic release, with rotary door handle, spreader links, phase barrier etc. 1 No., 63 Amp. 4 pole 10 KA MCB. 1 No., 40 Amp. 4 pole 10 KA MCB. 1 No., 32 Amp. 4 pole 10 KA MCB. 1 No., 25 Amp. 2 pole 10 KA MCB. 3 Nos., Electronic Energy meter 1.0 class with RS 485 communication port & CT's. 6 Nos., Space heater with thermostat & MCB for protection. (In each section) Ventilation fans with filters & MCB for protection. (In each section). APFC Section:- 25 KVAr bank. 3 Nos., 12.5 KVAr bank. 2 Nos. 10 KVAr bank. 2 Nos., 5 KVAr bank. 1 No. Notes:- Provision for RYB Indications of EB & DG, shall be given in terminal blocks. Solar feeder & APFC section shall be ON as long as EB supply is available. Selection of MCCB shall be as per approved makes given along with this enquiry. Please refer SLD & ensure that all releases are as per specifications. Feeders having MCB's as outgoing will have double door & front doors will have a Acrylic window cutout. Each bank to have MCCB with adjustable thermal, fix magnetic release, spreader links, phase barrier etc. all MCCB ratings shall be as shown in SLD, Capacitor Duty Contactor , APP or gas filled capacitor, Start/Stop Push Buttons, On/Off indication, Auto/Manual Selector Switch, Electronic Timer. 8 point intelligent type APFC relay will ensure switching of appropriate bank to maintain P.F. at 0.999 or unity. Aluminium busbar of 300 Amp. @ 0.8 Amp / mm Current Density & 50 degree C ambient temperature. Panel shall be front access only with cable entry at top. Panel will have uniform depth throughout the length of the panel. Proper shrouding shall be provided on all live terminals. Maximum height of panel shall be 2375 mm including base frame of 75 mm.

1

-

-

... More
Supply, Installation, Testing & Commissioning of 3.5 C x 300 sq.mm, 1.1 KV grade, Stranded aluminium conductor, XLPE insulated, armoured, PVC outer sheathed cables conforming to IS:7098 ( Part-I ). The rates shall be inclusive of laying of cable in provided Trench/Pipe/Cable Tray. Termination of cables using double compression gland, crimping type lugs, etc. Each termination shall include supply of all necessary components, accessories, including double compression cable gland, cable lugs (crimping type) and consumables to make a complete termination in such a way that no live parts of the terminal and connecting lugs are exposed. While making termination, all other protection arrangement shall also be ensured. The cable tagging with proper ferrules shall be supplied & installed by the Contractor as part of cable termination work. Testing of the cables shall be as per specification & results shall be submitted to Engineer-in-Charge duly signed by contractor and authorized representative. Before Commissioning of cables Contractor need to check for physical damages & proper connection of all the terminals.

70

-

-

... More
Same as above but with 3.5 C x 185 sq. mm. Stranded Aluminium Conductor.

50

-

-

... More
Same as above but with 3.5 C x 50 sq. mm. Stranded Aluminium Conductor.

50

-

-

... More
Same as above but with 4.0 C x 6 sq. mm. Copper multi stranded.

150

-

-

... More
Same as above but with 4.0 C x 4 sq. mm. Copper multi stranded.

50

-

-

... More
Same as above but with 3.0 C x 6 sq. mm. Copper multi stranded.

150

-

-

... More
Same as above but with 3.0 C x 2.5 sq. mm. Copper multi stranded.

75

-

-

... More
Same as above but with 2.0 C x 2.5 sq. mm. Copper multi stranded.

1

-

-

... More
Supply & Installation of 4.0 C x 6 sq. mm 1.1 KV grade, Multi Stranded Copper conductor, PVC insulated, PVC outer sheathed cables conforming to IS:694 (1990). The rates shall be inclusive of laying of cable in provided Trench/Pipe/Conduit/Cable Tray. Testing of the cables shall be as per specification & results shall be submitted to Engineer-in-Charge duly signed by contractor and authorized representative. Before Commissioning of cables Contractor need to check for physical damages & proper connection of all the terminals.

20

-

-

... More
Same as above but with 4.0 C x 4.0 sq. mm. Copper multi stranded.

1

-

-

... More
Same as above but with 3.0 C x 2.5 sq. mm. Copper multi stranded.

250

-

-

... More
Termination of 4.0 C x 6 sq. mm, LT copper flexible cables using PVC cable gland of IP65, crimping type Copper lugs, etc. Each termination shall include supply of all necessary components, accessories, including PVC cable gland, cable lugs (crimping type) and consumables to make a complete termination in such a way that no live parts of the terminal and connecting lugs are exposed. While making termination, all other protection arrangement shall also be ensured. The cable tagging with proper ferrules shall be supplied & installed by the Contractor as part of cable termination work.

2

-

-

... More
Same as above but with 4.0 C x 4.0 sq. mm. Copper multi stranded.

1

-

-

... More
Same as above but with 3.0 C x 2.5 sq. mm. Copper multi stranded.

12

-

-

... More
Supply & Installation of 300 x 75 mm, Perforated type cable trays made out of 16 G CRCA sheet & Hot Dipped galvanized, with support at every 1.5 mt. interval using M.S. angle of size 40x40x5 mm Or Using Suspension GI rods. M.S. Support shall be painted with two coats of red oxide primer & two coats of silver paint. All necessary accessories required for installation of cable trays such as Cable Tray Supports, Clamps, Flat Strips, Joints, Hardware, etc shall be included in Installation rate.

30

-

-

... More
Same as above but of size 200 x 75 mm.

30

-

-

... More
Supply & Installation of 300 x 20 mm, cable tray cover made out of 18 G CRCA sheet & Hot Dipped galvanized, with all necessary accessories required for installation of cable tray covers such as Clamps, Flat Strips, Joints, Hardware, etc shall be included in Installation rate.

15

-

-

... More
Same as above but of size 200 x 40/50 mm.

15

-

-

... More
Supply, Installation, Testing & Commissioning of conventional spike type air termination suitable to carry lightning stroke made up of heavy gauge 40 mm dia copper pipe of standard length with 5 Nos. copper spikes fixed on copper ball as air terminals duly threaded in copper pipe erected on 5 meters height, The Lightning protection includes the Lightning counter comprising of digital display in an IP 67 enclosure with the minimum sensitivity of 1500A & maximum capacity of 220 KA counter & it should be tested as per IS/IEC, The Job also includes supporting mast using Galvanized Iron pipe of 3 meter length plus 2 meter pipe of FRP complete with base plate, Guy rope wires, Insulator, Clamps, Fasteners, Fan Hooks, hardware, etc.

6

-

-

... More
Supply, Installation, Testing & Commissioning of Primary light point wiring with 1.5 sq.mm. PVC insulated FRLS multistranded copper conductor wires, through PVC conduit concealed or surface mounted on ceiling/wall, point shall be controlled by 6 A modular type switch, with concealed/surface box, modular surface plate, ceiling rose/holder etc.

58

-

-

... More
Supply, Installation, Testing & Commissioning of Secondary light point wiring with 1.5 sq.mm. PVC insulated FRLS multistranded copper conductor wires, through PVC conduit concealed or surface mounted on ceiling/wall, point shall be controlled by 6 A modular type switch, with concealed/surface box, modular surface plate, ceiling rose/holder etc.

67

-

-

... More
Same as above but control shall be two way.

1

-

-

... More
Supply, Installation, Testing & Commissioning of fan point wiring with 1.5 sq.mm. PVC insulated copper conductor FRLS wires, through PVC conduit, concealed or surface mounted on ceiling/wall, point shall be controlled by 6 A modular type switch & step type electronic fan regulator with concealed/surface box, modular surface plate etc.

15

-

-

... More
Same as above but on lighting switch board ( Half Pt.).

20

-

-

... More
Supply, Installation, Testing & Commissioning of 6 Amp. socket point wiring with 2x1.5+1x1.0 sq.mm.PVC insulated copper conductor FRLS wires, through PVC conduit, concealed or surface mounted on the ceiling/wall, with modular type 6 Amp. switch & 5 pin socket, concealed/surface box, modular surface plate etc.

1

-

-

... More
Supply, Installation, Testing & Commissioning of 6 A sockets with modular type switches, concealed/surface box, modular surface plate etc., without any wiring & conduit ( wiring & conduit will be measured in mains ).

30

-

-

... More
Supply, Installation, Testing & Commissioning of 6/16 A socket point wiring with 2x2.5+1x1.5 sq.mm.PVC insulated copper conductor FRLS wires, through PVC conduit, concealed/surface mounted on the ceiling/wall, with modular type 16 Amp. switch & 6/16 A socket, concealed/surface box, modular surface plate etc.

1

-

-

... More
Supply, Installation, Testing & Commissioning of 6/16 A socket point with modular type switches, concealed/surface box, modular surface plate etc., without any wiring & conduit (wiring & conduit will be measured in mains ).

24

-

-

... More
Supply, Installation, Testing & Commissioning of Bell point wiring with 1.5 sq.mm, Bell push button, Bell buzzer all modular typr, PVC insulated copper conductor FRLS wires, through PVC conduit, concealed/surface mounted on the ceiling/wall, with modular type bell push and reset type bell with indicator.

1

-

-

... More
Supply, Installation, Testing & Commissioning of telephone point wiring with 2 pair telephone wire, through provided PVC conduit, concealed/surface mounted on the ceiling/wall with modular type RJ11 telephone socket, concealed/surface box, modular surface box etc. ( Telephone wire & PVC conduit will be measured separately ).

4

-

-

... More
Supply, Installation, Testing & Commissioning of TV point wiring with RG 6 co-axial cable, through provided PVC conduit, concealed/surface mounted on the ceiling/wall, with modular type TV socket, concealed/ surface box, modular surface plate etc. (RG 6 cable & PVC conduit will be measured separately ).

1

-

-

... More
Supply, Installation, Testing & Commissioning of data outlet sockets with CAT 6 UTP cable, through provided PVC conduit, concealed/surface mounted on the ceiling/wall, with modular type RJ 45 data outlet socket, concealed/surface box, modular surface plate and connection at both ends. ( CAT 6 UTP cable & PVC conduit will be measured separately ).

4

-

-

... More
Supply & Installation of 25mm medium duty PVC conduit with standard accessories and to be used for concealed / surface mounted on the ceiling/wall.

300

-

-

... More
Same as above but with 32 mm

1

-

-

... More
Supply & Installation of 25 mm wire reinforced type flexible PVC conduit with PVC glands on both sides to be used for flexible copper wires / cables.

50

-

-

... More
Same as above but with 32 mm

1

-

-

... More
Supply, Installation, Testing & Commissioning of mains / sub-main wiring using FRLS type wires of 2x2.5 sq.mm. + 1x1.5 sq.mm. PVC insulated, multistranded copper conductor through existing PVC conduit. ( Measurement of conduit & wires shall be separate ).

450

-

-

... More
Same as above but with 2x4.0 sq.mm. + 1x2.5 sq.mm.

60

-

-

... More
Same as above but with 6.0 sq.mm

50

-

-

... More
Same as above but with 4.0 sq.mm

50

-

-

... More
Same as above but with 2.5 sq.mm

1

-

-

... More
Supply, Installation, Testing & Commissioning of telephone wires of 2 pair with 0.5 mm dia. through existing PVC conduit.

80

-

-

... More
Supply, Installation, Testing & Commissioning of Jelly filled armoured telephone cable of 10 pair with 0.5mm dia liad through existing HDPE pipes

50

-

-

... More
Supply & Installation of 10 pair krone type telephone junction box.

1

-

-

... More
Supply, Installation, Testing & Commissioning of Co-axial cable low voltage grade RG-11 through existing PVC conduit.

30

-

-

... More
Supply, Installation, Testing & Commissioning of CAT 6 UTP data cable through existing PVC conduit.

120

-

-

... More
Supply & Installation of 100x50 mm PVC plastic trunking with flexible cover, base joint, aluminium clip on partition, end caps, internal angle, clips etc.

1

-

-

... More
Supply & Installation of 'B' grade GI pipe down rod duly painted for fan complete erected with PVC three core flexible cable of 1 sqmm copper PVC wire.

30

-

-

... More
Supply, installation, testing & commissioning of IP54/55 Street Light Control Box, comprising of following: Incoming 10 Amp. 4 Pole MCB 10 KA as incomer 1 No., 6 Amp. 4 pole MCB 10 KA 2 nos., 6 Amp. 2 pole MCB 10 KA 1 no. as outgoing. Timer based system: Allows one to set the ON and OFF time, through Programmable Astronomical Time Switch with automatically adjusts the set time along with seasonal variation to control ON / OFF for lighting on purpose of realizing that light is turned ON when sun sets & turned OFF when sun rises. Selector switch for Auto/ Manual operation. ON/OFF push buttons, indicator lamps, control wiring, metering device, etc for automatic operation & overcurrent, short circuit, earth fault protection of street lights. Wall mounted. Enclosure with CRCA Sheet Steel duly phosphatized and powder coated with 7 tank process. Pre-wired. Louvers provided on both sides for proper heat dissipation.

1

-

-

... More
Supply, Installation, Testing & Commissioning of 4 way VTPN MCB DB with double door, comprising of following: Incoming : 63 A 4 pole MCB 10 KA 1 No. Outgoing : 32 A 3 pole MCB. 10 KA. 3 Nos. 16 A 1 pole MCB. 10 KA. 3 Nos.

1

-

-

... More
Supply, Installation, Testing & Commissioning of 6 way PPI MCB DB with double door, comprising of following: Incoming : 25 A 4 pole MCB 10 KA 1 No. 25 A DP RCCB 30 mA Hpi type. 3 Nos. Outgoing : 10 A 1 pole MCB. 10 KA. 12 Nos.

1

-

-

... More
Supply, Installation, Testing & Commissioning of 4 way PPI MCB DB with double door, comprising of following: Incoming : 25 A 4 pole MCB 10 KA 1 No. 25 A DP RCCB 30 mA Hpi type. 3 Nos. Outgoing : 10 A 1 pole MCB. 10 KA. 6 Nos.

2

-

-

... More
Supply, installation, testing & commissioning of 8 way SPN MCB DB with double door, comprising of following: Incoming : 25 A DP RCBO 30 mA Hpi type. 1 No. Outgoing : 10 A 1 pole 10 KA MCB. 4 Nos.

3

-

-

... More
Supply, installation, testing & commissioning of 8 way SPN MCB DB with double door, comprising of 25/32 A FP MCB 10 KA 2 Nos.

1

-

-

... More
Supply, Installation, Testing & Commissioning of MCB & socket boxes of IP 65 annd having 16 Amp. DP MCB 10 KA with 16 Amp. 1 Ph. 3 pin Socket & 32 Amp. FP MCB 10 KA with 32 Amp. 3 Ph. 4 wire with E socket. PVC Box shall be combine for both the sockets.

2

-

-

... More
Supply, Installation, Testing & Commissioning of MCB & socket boxes of IP 65 and having 16 Amp. DP MCB 10 KA with 16 Amp. 1 Ph. 3 pin Socket & 16 Amp. FP MCB 10 KA with 16 Amp. 3 Ph. 4 wire with E socket. PVC Box shall be combine for both the sockets.

2

-

-

... More
Supply, Installation, Testing & Commissioning of 6 to 32 A DP MCB with MS box.

1

-

-

... More
Supply, Installation, Testing & Commissioning of IP 65, PVC Junction box with 4way connectors & earthing terminal inside.

1

-

-

... More
Supply, Installation, Testing & Commissioning of IP 65, PVC Junction box with 2way connectors & earthing terminal inside.

10

-

-

... More
Supply, Installation, Testing & Commissioning of 20 Watt LED Capsule type IP 65 protection, suitable for surface mounting. System Efficacy 90, Colour Temp 6500K, CRI Value minimum 80, Operating Temperature is 0 Deg. Driver having voltage range of 120 - 300 Volts, THD less than 10%, P.F. greater than 0.95, surge protection =2.5 KV, inbuilt over voltage & under voltage protection. Complete with mounting bracket suitable for Surface mounting, wiring etc.

22

-

-

... More
Supply, Installation, Testing & Commissioning of 15W LED Recess mounted Round Downlighter, 6500K, IP20, System Efficacy 90, CRI Value minimum 80, Driver having voltage range of 140 - 280 Volts, THD less than 10%, P.F. greater than 0.95, surge protection =2.5 KV, inbuilt over voltage & under voltage protection.

2

-

-

... More
Supply, Installation, Testing & Commissioning of 6W LED Surface mounted Round Downlighter, 6500K, IP20, System Efficacy 90, CRI Value minimum 80, Driver having voltage range of 140 - 280 Volts, THD less than 10%, P.F. greater than 0.95, surge protection =2.5 KV, inbuilt over voltage & under voltage protection.

1

-

-

... More
Supply, Installation, Testing & Commissioning of 7 watt (Colour Temp 5700/6000K)direct fitting LED bulbs.

6

-

-

... More
Supply, Installation, Testing & Commissioning of wall mounted 70 watt LED Street Light, IP65 protection, luminaire with ADC housing & clear cover, Wall mounting bracket and accessory suitable for outdoor installation. System Efficacy 100, Colour Temp 6500K, CRI Value minimum 80, Driver having voltage range of 110 - 290 Volts, THD less than 10%, P.F. greater than 0.95, surge protection = 4 KV, inbuilt over voltage & under voltage protection. Mounting height of the fitting will be around 9.0 meters.

1

-

-

... More
Supply, Installation, Testing & Commissioning of Integral LED post top 40 watt fitting, complete with wiring etc.

2

-

-

... More
Supply, Installation, Testing & Commissioning of 1200 mm sweep 5 star rated ceiling fan with double bearing complete with wiring etc.

15

-

-

... More
Supply, Installation, Testing & Commissioning of 225 mm sweep fresh air cum exhaust fan with bird screen.- cfm for ventilation fans is 425 (±10%)

4

-

-

... More
Supply, Installation, Testing & Commissioning of 375/380 mm sweep heavy duty exhaust fan with bird screen.- cfm for ventilation fans is 1470 (±10%)

4

-

-

... More
Supply, Installation, Testing & Commissioning of 450 mm sweep heavy duty exhaust fan with bird screen.- cfm for ventilation fans is 2650 (±10%)

1

-

-

... More
Supply, Installation, Testing & Commissioning of audio, visual alarm system for cold storage rooms. Job involves solid state Annunciator with hooter & enclosure, installed in occupied area, stay-put type push button station in each cold rooms / pre cooling rooms, cabling from cold rooms / pre cooling rooms to Annunciator. Job involves following items. 4 points Annunciator - 1 No Stay-put type push buttons. - 4 Nos. 2Cx0.75 sq. mm.Copper Flexible multi stranded cable. - 150 Mtrs Medium duty PVC conduit of 25 mm size with standard accessories. - 100 Mtrs

1

-

-

... More
PART-5: Miscellaneous Items

-

-

-

... More
Pallets Dimensions: 1000mm X 1200mm X 150 mm approx. ht Colour: as approved by client Pallet type: four side fork opening Weight carrying capacity: 1500 Kg Suitable to use with all kind of material handling equipments including hand pallet trucks etc. Working Temperature range: (-) 25 deg C to (+) 10 deg C heavy duty type, Top Deck : Perforated MOC Shall be food grade plastic/HDPE and shall have excellent impact strength and high compression resistance. Acceptable makes: Nilkamal/Supreme / Eqvt

200

-

-

... More
Hydraulically Operated Hand Pallet Truck Type : Hydraulically operated Hand Pallet Truck Manufacturer : Godrej / Toyota / Linde / Jungheinrich / Nilkamal / Josts / Eqvt. Model No. : to be mentioned Load Capacity in kgs: 1500 kg Fork Length in mm (Suitable for liifting pallet of size of 1000 mm X1200 mm X154 mm ) Wheel MOC : Nylon / Polyurethane Suitable for heavy duty operation and long life,

2

-

-

... More
Overhauling of Machineries for 1 precooling chamber, 4 cold rooms ,ante-room , transformer, DG sets, HT/LT/APFC panels and other electrical system, dock,grading sorting line and overall any activity not mentioned but needed to carry out utilizing the equipment in effective manner. It is recommended that bidder shall visit the site and get the idea of quantom of work before quoting.

1

-

-

... More
The details of the exisiting machinery is as follows, • PRE-COOLING CHAMBER:1 no, CDU (2 nos), Air Handling Unit 43 kW capacity, water pump: 1 x 3 Kw, 1 no • Cold Storage 1,2,3,4: CDU: air cooled condensing unit 1 no for each room., Air Cooling Unit: 13.5 KW each unit • Ante-room: Air cooled condesing nuit and indoor unit 1 nos • Evaporative air cooling units: Qty-2 nos • Air curtains, QTY: 13 Nos. • Grading Sorting Lines • Transformer: 200 KVA • DG set: 200 KVA • 11 KV Outdoor type MCCB panel • Main PCC panel • APFC panel:microcontroller based. • Lighting fixtures: internal as well as external street lighting of different wattage

-

-

-

... More
Scope of Work for Refrigeration System: • Checking of operational log readings recorded by operators during the previous month.& Discussion operational problems, if any, with maintenance/operation staff. • Checking the actual performance of the machines and Checking & correcting the set parameters, if required. • Carrying out minor repairs. Replace minor parts ,if required. • Making recommendations to client for smooth & trouble free operation of the machines. • Cleaning & combing of ACU’s fins, suction filters, driers, pump ,strainers etc. •ACU fan & motor- routine & preventive maintenance • To check oil level in the compressor, if less then oil to be charged in to the compressor. • Check liquid sight glass to determine the shortage of refrigerant if any / to check moisture contained in the system. Top up if required. • Inspect system for visible signs of leaks. If found, attend the leaks. If any brazing work involved should be carried out by the contractor at his cost • Inspect & adjust, if required, all safety controls. • carrying out calibration of gauges, temperature , RH sensors etc, wherever caliberation time frame has exceeded • Inspect the condition of refrigerant and drain pipe insulation (drain pipe insulation wherever applicable).To be replaced if found not in good condition. • Condenser inlet air pre-cooling system - to be cleaned, pump repaired (if required), pipig cleaned and other routine and preventive maintenance.

-

-

-

... More
Scope of Work for Insulated Sandwich Panels: • Insulated Panel Structure: Filling of silicon sealant as & where required to stop air leakages if any. • Floor Insulation – checking for gaps created between civil floor and wall insulation and sealing the same with silicon sealant / PUF filling depending on the size of the gap, if created during regular wear and tear or minor damage. • PUF foaming in case condensation due to leakage etc found. Scope of Work for Insulated Doors, Strip and Air curtains, Dock shelters: • Cleaning and oiling of rollers of doors • Gasket checking for leakage. Alignment of gasket if leakage is observed. • Replacement of gasket if gasket is damaged or found in improper condition. • P.V.C. strip Curtains: Replacement of PVC strips if any. • Air Curtains – check the overall condition. Replacement of blower/full unit, if required. • Dock shelter- check for any damage, leackage etc. appropriate action to be taken to so as to make them fully funcational. • Dock leveller: cleaning, lubricating the parts with proper lubracants, All necessary components are adjusted properly to make sure equipment works smoothly and consistently.check fluid level in hydraulic cylinders, top-up/ replace the fluid as may be necessary.

-

-

-

... More
Scope of work for Electrical System: • Transformer: oil condition checking, leakages to be attended, testing of oil for various parameters as per standard practice, Filtration or replacement / top up of oil as per condition of oil, Insulation resistance of the transformer should be checked, Bushings should be cleaned and inspected for any cracks, checking of any loose connections of the terminations of HV & LV side, breather examination. Dehydration of Silica gel if necessary. Explosion-vent diaphragm examination. Conservator to be cleaned from inside. Cleanliness in the Substation yard with all nets, vines, shrubs removed. • DG set: Routine & preventive maintenance of DG sets with AMF panels including maintenance of controlling/protective accessories, battery check. Replace/charge as required. DG set general servicing as per manufacturers recommendation. replacement of filters etc. as required. •HT / LT panels: Check for loose connection of all terminals in the panels, Clean gently the dust by air pressure in side the panels, Check the mounting of CTs for its position, ensure that does not make contact with body, Check for loose connections for all power / neutral cable connections, Check for all the fuses, Check for loose connections of all power cables & control cables of panel, Check for loose connections of cables of meters / contractors, Check the outgoing & incoming phase, neutral connection of circuit breaker, Check the thermal trip of circuit breaker, Check mountings of circuit breaker & tightness of power cables. If anything mentioned above found not normal, same shall be rectified • APFC panel: Cleaning should done by using blower. Microcontroller not working condition to be replaced. Current of each capacitor should be measured and recorded once in month to know healthiness of each capacitor bank. Current should be measured by using clamp tester. If the value of current is less than 50% of the rated value. Capacitor should be replaced with new one. Connections should be checked for any loose connections. • Routine, preventive maintenance of Lighting & Power Distribution Systems. • Routine, preventive maintenance of HT, LT cables & Wirings. • Earth resistance measurement of all the Earth electrodes • Checking, fitting cleaning and fault rectification of the lighting fixtures

-

-

-

... More
Scope of Work for Conveyor Line: • Motor - checking of alignment of motors • Bearing at various locations to be checked and oiled / greased wherever necessary • Lubrication to be carried out for all the rollers as necessary to avoid any squeaking noises. • Belt alignment • Pulley conditon checking • Heaters operation check and routine & preventive maintenance for dryer and hot water treatment units. • Washer Unit: water spray nozzels, brushes etc checking and routine maintenance. • Electronic weight sizer: routine & preventive maintenance. • Electrical control panel: routine & preventive maintenance. • Painting of parts wherever necessary to prevent parts from being rusted. Overall the grading sorting machineries are to be cleaned and made ready for use considering that they may be used for export oriented purpose. Parts that are coming in contact with the product during operation should be ensured to be of allowable SS or other food grade material. If any part like motor etc. needs replacement, then the cost of the motor / major part would be borne by the end-user / MSAMB / user but the installation and commissioning of the part shall have to be done as part of this contract and the labour costs and minor accessories for the same to be considered. For this, a site visit for seeing the condition of the equipment is extremely critical.

-

-

-

... More
Evaporative air cooling units: • Remove the filer pads and clean them thoroughly with a pressurized water jet • Water Sump cleaning • Water pump routine & preventive maintenance • Fan and Belts- check condition, preventive and routine maintenace • Air leaks in ducting and Water Leaks- check and attend if any • Electircal & contro System- checking, preventive and routine maintenace

-

-

-

... More
Training Hall Electrical Works

-

-

-

... More
Projector for Training Hall

-

-

-

... More
Supplying, installing, testing & comissioning of PROJECTOR - 3LCD, Brightness 5000 lumens , Contrast 5000:1 Resolution 1920 x 1200, Lamp Life 8000 Eco / 5000 Normal, , Full HD

1

-

-

... More
Supplying, installing, testing & comissioning of HDMI cable Platinum 20/15 mtr 4K compability

1

-

-

... More
MOT. SCREEN - Motorised imported screen (100" diagonal) with black border and tubular motor driving device with less noise and smooth fuctioning. Actual viewing area shall be 60" H X 80" W. (Imported High Contrast Silver Fabric 4k Full HD)

1

-

-

... More
Supplying, installing, testing & comissioning of MOT. LIFT -Motorised projector Lift with Heavy duty, all metal construction with rack and tubular motor, mechanism should have quiet operation. The lift shall close at max 14 inches , including the projectorand shall be able to move down unto 42 inches for projection.

1

-

-

... More
Audio/ Sound system for Training Hall

-

-

-

... More
Supplying, installing, testing & comissioning of Wall mounting speakers with power of 30 watts, size-6.9", sensitivity upto 93db, frequency rate 60 Hz – 18kHz (-10 dB). White colour complete with wiring and required acessories etc

6

-

-

... More
Supplying, installing, testing & comissioning of Premium In-Wall Two-Way Loudspeaker with 6-1/2" (165 mm) Woofer. Polymer-Coated Aluminum-Cone Woofer With Pure Butyl Rubber Surround, Low-Diffraction Swivel Aimable Titanium Tweeter. High-Slope Crossover Network, Paintable, 98 mm ( 3-7/8 in) Depth (For Wallboard Plus Stud). 88 dB Sensitivity, 100 Watts (50W RMS/200W Peak), 38 Hz to 20 kHz Frequency Response. ( Subwoofer 02no.) (1Pair) complete with wiring and required acessories etc

2

-

-

... More
Supplying, installing, testing & comissioning of Multi Channel amplifier with 8 channels of 50W each Channels may be bridged in pairs for combined power, Terminals for remote control of channel levels/muting, Balanced line-level inputs on plug-in barrier strips, complete with wiring and required acessories etc

1

-

-

... More
Supplying, installing, testing & comissioning of Lapel or Hand Microphone complete with wiring and required acessories etc

2

-

-

... More
Supplying, installing, testing & comissioning of Table embedded microphones with high sensitivity guarantees a constant output level even from long distance sources. These microphones are designed for applications such as tele/video conferencing or recording. Frequency response -60 - 20,000 Hz Impedance 200 ohms complete with wiring and required acessories etc

1

-

-

... More
Supplying, installing, testing & comissioning of A combination of 2 relays and 1 I/O to be used for each of the above switch, to activate/deactivate a microphone and to enable " look at me" feature complete with wiring and required acessories etc

1

-

-

... More
Supplying, installing, testing & comissioning of Digital Sound processor with tele hybrid. NEXIA TC is a digital signal processor with 8 wide-band AEC mic/line inputs, 2 standard mic/line inputs, 4 mic/line outputs, and a telephone interface.(No need to have additional audio conf. unit) complete with wiring and required acessories etc

1

-

-

... More
Video Conference system for Training Hall

-

-

-

... More
Supplying, installing, testing & comissioning of Video Conference -R ealPresence Group 500-720p: Group 500 HD codec, EagleEyeIV-12x camera, mic array, univ. remote, NTSC/PAL. Cables: 2 HDMI 1.8m, 1 CAT 5E LAN 3.6m, 1 HDCI analog 3m, Power: UK-Type G, BS 1363. Maintenance Contract Required complete with wiring and required acessories etc

1

-

-

... More
Supplying, installing, testing & comissioning of Partner Premier (Group Series) -Polycom Advantage, 3 Year, RealPresence Group 500-720p: Group 500 HD codec, EagleEyeIV-12x camera complete with wiring and required acessories etc

1

-

-

... More
Supplying, installing, testing & comissioning of Group Series Multipoint License - 6-way on Group 500 or 8-way on Group 700. Both support 4-way HD continuous presence. NOTE- CALA and China include Maintenance in price. ROW require purchase of separate service Product ID complete with wiring and required acessories etc

1

-

-

... More
Supplying, installing, testing & comissioning of Display 42" Full HD 1080 with Inbuild Wi-Fi & 3 HDMI Port / 2 HDMI Port complete with wiring and required acessories etc

1

-

-

... More
Point wiring for light/fan/bell concealed type in min 20 mm ISI marked HMS PVC conduit with 1.5 sq.mm. (2+1E) FR grade copper wires, moduler type switch, earthing and required accessaries as per specification No: WG-PW/CW 1.9.9

149

-

-

... More
Supplying and erecting modular type 3 pin 6A multi socket with safety shutter ISI mark approved make duly erected on provided plate and box with wiring connections complete. 1.8.10

16

-

-

... More
Supplying and erecting modular type 3 pin 6 / 16A multi socket with safety shutter ISI mark approved make duly erected on provided plate and box with wiring connections complete. 1.8.11

10

-

-

... More
Supplying and erecting modular type electronic step regulator for fan two module ISI mark approved make duly erected on provided plate and box with wiring connections complete. Note: Add Rs 57/- provision of additional two modules for box and double plate 1.8.23

14

-

-

... More
Supplying and erecting regular/ standard model Ceiling fan of 1400mm. sweep complete erected in position as per specifcation no. FGFN/CF 2.12.3

14

-

-

... More
Supplying and erecting Exhaust fan heavy duty 230 V A.C. 50 cycles 450 mm. 1400 RPM complete erected in position as per specifcation no. FG-FN/EXF 2.12.18

10

-

-

... More
Supplying and erecting Exhaust fan heavy duty 230 V A.C. 50 cycles 375/380 mm. 1400 RPM complete erected in position as perspecifcation no. FG-FN/EXF 2.12.17

4

-

-

... More
Supplying and erecting LED square / circular 16 to 20W downlighter having pressure diecast aluminimum housing, opal translucent cover, mounting arrangement with board for surface type or spring loaded mounting clips for flush type complete. 2.1.5

72

-

-

... More
Supplying and erecting LED square / circular 13 to 15W downlighter having pressure diecast aluminum housing, opal translucent cover, mounting arrangement with board for surface type or spring loaded mounting clips for flush type complete. 2.1.4

4

-

-

... More
Supplying and erecting Ding Dong / electronic musical type call bell with heavy duty coil suitable to operate on 230V A.C. supply erected on polished double wooden block/sunmica block of suitable size 2.4.13

1

-

-

... More
Supplying and erecting LED Street light fitting suitable for 60w lamp, including lamp, with PF 0.95 class IP 65 and above Housing of pressure die cast alluminium alloy and heat sink extruded alluminium complete per specification No . FG-ODF/FLS2. 2-5-5

4

-

-

... More
Supplying and erecting street light Wall bracket made from 40 mm.dia ‘B’class G.I. pipe 1.2 m in total length complete as per specificationno. FG-BKT/WB 2.9.4

4

-

-

... More
Supplying, installing, testing and commissioning split type variable speed Inverter technology room Air conditioning unit 2 TR capacity having ISEER minimum 3.50 to maximum 3.99 suitable to operate on 250V, 50 cycles, A.C. supply having 1 no. of air handling unit hi-wall/ floor mounting type complete with Refrigerants R410 A/R32 and copper condenser at position. specification no. AP-AC/SAC 3.2.6

12

-

-

... More
Supplying & erecting original 1.25 mm CRCA sheet metal enclosures with 20A. 2 pin plug & earth socket and 20A. 3 pin plug top with 20A/30A single pole MCB complete erected on angle iron/ G.I. frame.. 5.4.20

12

-

-

... More
Supplying, erecting & marking SPMCB 6A to 32A, C-series (for motor/power) in provided distribution board as per specification No. SWSWR/ MCB 5.3.2

18

-

-

... More
Supplying, erecting & marking TPMCB 6A to 32A in provided distribution board as per specification No. SW-SWR/MCB 5.3.14

2

-

-

... More
Supplying and erecting Bus bar chamber triple pole with neutral with four aluminium bars, 500V, 100A complete as per specification no. CP-BB 6.2.1

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.