City And Industrial Development Corporation Of Maharashtra Limited Tender
Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.
City And Industrial Development Corporation Of Maharashtra Limited - CIDCO Tender
Eprocure
Opening Date23 Jun 2021
Closing Date5 Jul 2021
Tender AmountRefer Documents
Costs
EMD
Refer DocumentsDocument Cost
₹ 11,800Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2021_CIDCO_698615_1Bid Award Id
ViewTender No
CANo14/CIDCO/CE(NMIA)/SE(CP)22Tender Authority
City And Industrial Development Corporation Of Maharashtra Limited ViewPurchaser Address
-Website
http://mahatenders.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
(B) Dedicated COVID Health Centre in CCI Godown, Kalamboli, Navi Mumbai
-
-
-
Infant, Pediatric and Adult Ventilator: Supply, Installation, Testing and Training of equipment with 1 year manufacturers warranty. Specification: Should be suitable for infant, pediatric and adult range of patients with Invasive / Non Invasive configurations. Should have the following ventilation modes A/C-PC, A/C-VC, CPAP, PSV, S/T, SIMV-PC, SIMV-VC, AVAPS-AE, MPV-PC and MPV-VC. Built-in battery backup of 4 hours or more. Coloured screen of 7 inches or more. Should have comprehensive range of alarms such as aspiratory pressure, tidal volume, minute ventilation, respiratory rate, circuit disconnection, apnea interval, no-trigger etc. Should have additional features such as inspiratory hold and expiratory hold. Tidal volume range for Adult patient type: 50 to 2000 mL and for Paediatric patient type: 50 to 300 mL. Maximum flow 280 L/min. Inspiratory Flow Trigger (inspiratory trigger) Off, 1 to 20 L/min. Inspiratory Pressure Trigger Off, Very Low to Very High. Apnoea Resp. Rate- Adult: 1 to 60 bpm / Paed: 1 to 60 bpm Rate: upto. I:E ratio:1:6 to 6:1 PEEP : upto 50 cmH2O Inspiratory Pressure: upto 60 cmH2O. Alarms- Tidal volume, Respiratory rate, Pressure, High pressure, Disconnection Low pressure, PEEP, breathing circuit, High leak NV Mask Flow sensor not calibrated, Circuit configuration alarms Oxygen, Apnoea, Ventilation stopped, Power, System alarms. Should have data management capabilities and onscreen FiO2. Real-time pressure vs time, volume vs time & flow vs time waveforms. loops for Pressure-flow, Pressure-volume, Flow-volume. display and essential therapy parameters on the large touch screen 10 inches. Should monitor the following parameters- Tidal Volume, Frequency and Minute Volume, Peak, Mean, PEEP and Plateau pressure, Spontaneous Minute Volume, Leakage volume, RSBI, Static and dynamic lung compliance, Inspiration and expiration time. Should be supplied with 1 NO.. air inlet filter, 1 NO.. exhalation valve, 1 NO.. disposable adult and paediatric patient circuit and Non Vented disposable full face mask and 1 NO.. humidifier. Certification from relevant competent authority(s)
5
-
-
Dialysis Machine: Supply, Installation, Testing and Training of equipment with 1 year manufacturers warranty. Specification: should have facility for conventional dialysis. Battery back-up for 20-30 minutes to run complete machine with heater supply. Should Have Na, Bicarbonate And Uf Profiling. Dialysate temperatures selectable between 35°c to 39°c or wider. Variable conductivity setting between 12.5 to 15 ms/cm or wider. Should have variable dialysate flow at least 350-800 ml/min and should have increasing facility in steps. Should have facility to show trends curve of all parameter for 15-20 minutes. Heparin pump with adaptability of various sizes of syringes up to 30 ml with pump flow rate from 1-10ml/hr.( 0.1 ml increments). Ultra filtration 0.1 to 2.5 liters/hr. or more. The in and out fluid circuit must be separated so that there is no chance of contamination in the event of membrane rupture. Treatment parameter should be displayed by graph and digitally both. Should have integrated heat and chemical disinfection facility with both short and long disinfection. Programme with day, night and week schedule. Should have accurate feedback control conductivity mixing technique. Should have drain facility, should have accurate uf control by flow by volume control measurement technique. Should have blood volume sensor. Should have automatic self-test facility. Should have auto ON/OFF Facility. Should have user friendly display system. Blood pump rate at least from 50 – 600 ml/min or wider adaptable to standard A-V bloodlines. Alarm for reverse Ultra filtration and also be able to do sequential dialysis, Audio visual alarms on limit violation of conductivity, blood leak, air leak, trans-membrane pressure, dialysis temperature, hemodialysis Completion, end of disinfection process, bypass and blood pump stop, dialysate empty. Machine should have facility for variable Sodium, Acetate, Bicarbonate, Regulated Ultra Filtration, Sequential Dialysis (Isolated UF). Should have certification from competent authority(s)
10
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements