Chandrapur Cancer Care Foundation Tender
Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.
Chandrapur Cancer Care Foundation Tender
Electrical Goods and Equipments
Electrical and Electronics
Eprocure
Opening Date13 Feb 2024
Closing Date6 Mar 2024
Tender AmountRefer Documents
Costs
EMD
0Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_CHDPR_1003705_1Bid Award Id
ViewTender No
F2_CCCH/V/Electrical/2024Tender Authority
Chandrapur Cancer Care Foundation ViewPurchaser Address
-Website
http://mahatenders.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
External lighting-Feeder Pilar Outdoor Type IP 65 Design, supply, installation & commissioning of floor/ wall mounting/ free standing, totally enclosed compart-mentalized, cubical, dust, vermin proof external lighting panel fabricated out of 2mm thick cold rolled carbon annealed, sheet steel, internally straightened with 35mm x35mm x6mm angle iron frame work with hinged centre opening type double doors, (fabricated out of 2mm CRCA sheet steel) The fabricated panel with IP-65 as enclosure protection as per specification. Supplying and mounting including making connections/ interconnection with lugs/ glands testing and commissioning of following items inside the panel. Incomer
Aluminium bus strips of high electrolytic conductivity 200A, 3- Phase with neutal, 415V, 50 Hz, (+/- 10%) AC supply -1set. MCCB 4 pole 100 Amps, 25 kA, 415 V, 3 phase, AC supply with in built overload, short circuit & ON/ OFF indication on the front- 1No. LED type phase indicating (R-Y-B) lamps provided with MCB's protections and individual toggle switches having lens and lamp visible from the front -1set. 1 Set of (0-500V) voltmeter with selector switch & Control MCB's. 1 Set of (0-100A) ammeter with selector switch & 100/5A ratio CTs. 1 No. Astronomical timer Outgoings
MCBs 16A/20A, DP, 10kA, C series -12 Nos. on each phase MCBs 25A/40A, 4P, 10kA, C series -5 Nos. Feeder Pillar as described above
3
-
-
Boom Barrier System Supply, installation, testing and commissioning of automatic boom barrier suitable for 5.0m-7.5m road width forintensive applications, high speed with 4.5 second opening time with Straight aluminium boom of minimum size 100mm x 70 mm, builtin blinker indicator etc. complete asrequired as per specifications & at site of work.
2
-
-
Boom Barrier System Supply, installation, testing and commissioning of a set of Entry/ Exit push buttons for manual open and closing of barrier etc.complete as required.
2
-
-
PANEL SUPPRESSION SYSTEM Design, supply, fixing, testing and commissioning of automatic Linear pneumatic Tube Detection based FK-5-1-12 /Novec 1230 Fluid (UL Listed) System for Electrical Panels (Linear Pnuematic Heat Detection Tube Panel Protection System),consisting of following components for Electrical Panel: 4 Kg Novec 1230 Fluid/FK-5-1-12 , DLP Assembly with automatic valve, push in connector for tube, mounting bracket, End of Line adaptor and low pressure switch for monitoring system activation. Linear pneumatic heat Detection Tube with all necessary fittings & supports.
A/V Alarm with battery backup Main LT Panel Dimensions : 14 m (W) x 1.5 m (D) x 2.2 m (H)
1
-
-
PANEL SUPPRESSION SYSTEM Design, supply, fixing, testing and commissioning of automatic Linear pneumatic Tube Detection based FK-5-1-12 /Novec 1230 Fluid (UL Listed) System for Electrical Panels (Linear Pnuematic Heat Detection Tube Panel Protection System),consisting of following components for Electrical Panel: 4 Kg Novec 1230 Fluid/FK-5-1-12 , DLP Assembly with automatic valve, push in connector for tube, mounting bracket, End of Line adaptor and low pressure switch for monitoring system activation. Linear pneumatic heat Detection Tube with all necessary fittings & supports.
A/V Alarm with battery backup HT Panel Dimensions : 3 m (W) x 2 m (D) x 2.2 m (H)
1
-
-
PANEL SUPPRESSION SYSTEM Design, supply, fixing, testing and commissioning of automatic Linear pneumatic Tube Detection based FK-5-1-12 /Novec 1230 Fluid (UL Listed) System for Electrical Panels (Linear Pnuematic Heat Detection Tube Panel Protection System),consisting of following components for Electrical Panel: 4 Kg Novec 1230 Fluid/FK-5-1-12 , DLP Assembly with automatic valve, push in connector for tube, mounting bracket, End of Line adaptor and low pressure switch for monitoring system activation. Linear pneumatic heat Detection Tube with all necessary fittings & supports.
A/V Alarm with battery backup DG Panel Dimensions : 6 m (W) x 1.5 m (D) x 2.2 m (H)
1
-
-
PANEL SUPPRESSION SYSTEM Design, supply, fixing, testing and commissioning of automatic Linear pneumatic Tube Detection based FK-5-1-12 /Novec 1230 Fluid (UL Listed) System for Electrical Panels (Linear Pnuematic Heat Detection Tube Panel Protection System),consisting of following components for Electrical Panel: 4 Kg Novec 1230 Fluid/FK-5-1-12 , DLP Assembly with automatic valve, push in connector for tube, mounting bracket, End of Line adaptor and low pressure switch for monitoring system activation. Linear pneumatic heat Detection Tube with all necessary fittings & supports.
A/V Alarm with battery backup Fire Emergency Panel Dimensions : 5 m (W) x 1.2 m (D) x 1.8 m (H)
1
-
-
PANEL SUPPRESSION SYSTEM Design, supply, fixing, testing and commissioning of automatic Linear pneumatic Tube Detection based FK-5-1-12 /Novec 1230 Fluid (UL Listed) System for Electrical Panels (Linear Pnuematic Heat Detection Tube Panel Protection System),consisting of following components for Electrical Panel: 4 Kg Novec 1230 Fluid/FK-5-1-12 , DLP Assembly with automatic valve, push in connector for tube, mounting bracket, End of Line adaptor and low pressure switch for monitoring system activation. Linear pneumatic heat Detection Tube with all necessary fittings & supports.
A/V Alarm with battery backup Lift Panel-1 Dimensions : 2.5 m (W) x 0.6 m (D) x 1.6 m (H)
1
-
-
PANEL SUPPRESSION SYSTEM Design, supply, fixing, testing and commissioning of automatic Linear pneumatic Tube Detection based FK-5-1-12 /Novec 1230 Fluid (UL Listed) System for Electrical Panels (Linear Pnuematic Heat Detection Tube Panel Protection System),consisting of following components for Electrical Panel: 4 Kg Novec 1230 Fluid/FK-5-1-12 , DLP Assembly with automatic valve, push in connector for tube, mounting bracket, End of Line adaptor and low pressure switch for monitoring system activation. Linear pneumatic heat Detection Tube with all necessary fittings & supports.
A/V Alarm with battery backup Lift Panel-2 & 3 Dimensions : 1.1 m (W) x 0.6 m (D) x 1.6 m (H)
2
-
-
PANEL SUPPRESSION SYSTEM Design, supply, fixing, testing and commissioning of automatic Linear pneumatic Tube Detection based FK-5-1-12 /Novec 1230 Fluid (UL Listed) System for Electrical Panels (Linear Pnuematic Heat Detection Tube Panel Protection System),consisting of following components for Electrical Panel: 4 Kg Novec 1230 Fluid/FK-5-1-12 , DLP Assembly with automatic valve, push in connector for tube, mounting bracket, End of Line adaptor and low pressure switch for monitoring system activation. Linear pneumatic heat Detection Tube with all necessary fittings & supports.
A/V Alarm with battery backup Capacitor Panel - 1 & 2 Dimensions : 2.5 m (W) x 1.5 m (D) x 2.2 m (H)
2
-
-
PANEL SUPPRESSION SYSTEM Design, supply, fixing, testing and commissioning of automatic Linear pneumatic Tube Detection based FK-5-1-12 /Novec 1230 Fluid (UL Listed) System for Electrical Panels (Linear Pnuematic Heat Detection Tube Panel Protection System),consisting of following components for Electrical Panel: 4 Kg Novec 1230 Fluid/FK-5-1-12 , DLP Assembly with automatic valve, push in connector for tube, mounting bracket, End of Line adaptor and low pressure switch for monitoring system activation. Linear pneumatic heat Detection Tube with all necessary fittings & supports.
A/V Alarm with battery backup UPS Panel - 1 & 2 Dimensions : 2.5 m (W) x 0.6 m (D) x 1.6 m (H)
2
-
-
KITCHEN HOOD SUPRESSION SYSTEM Design, supply, fixing, testing and commissioning of automatic Kitchen Hood Suppressions System including the following 9 Liters FireDETEC ® F/K ea stainless steel cylinder, ILP Cylinder/valve assembly, mounting bracket, Flexible Hose, SS Tube fittings, Tube clamps, FireDeTec tube ( Grey) alongwith cross panel fittings , FDT tube clamps , Manual Release Device , with Pressure Switch and T connectors SS Tubing Nozzle 1 hole for kitchen system / R 1/4" / Stainless steel / Class F agent Alarm Box
3
-
-
Gas Shut Off Valve
2
-
-
TOTAL ROOM FLOODING SYSTEM
1x55 Itr completele CCOE approved high pressure seamless BIS 7285 approved Cylinders having 55 ltr capacity, UL/FM/VDS approved FK5-1-12 clean agent gas with UL/FM/VDS listed valve assembly and electric solinoid switch. The system also to be fitted with low pressure supervisory switch for monitoring cylinder pressure gauge with safety burst disc safety cap, elbow and other accessories, mounting bracket, container straps, NRV , Pressure operated control head which shall allow for pressure actuation of gas mounted, manually operated actuator to actuate the gas flooding process with the help of a lever, flexible rubber hose with wire bralded enforcment to route the gas from the storage cyinder to the discharge piping, to be connected to the discharge outlet of gas cylinder valve & to be terminated at the system piping or discharge manifold, Flexible actuation hose complete as required. Discharge nozzle, 180/360 degree. Designated to provide proper flow rate & distribution FK5-1-12 gas to flood the hazard area as per latest NFPA 2001 requrement. Piping ASTM grade A 106 schedule 40 with fittings & supports and Gas Release Panel compatible to Fire Alarm System. (UPS ROOM-1)
1
-
-
TOTAL ROOM FLOODING SYSTEM
1x55 Itr completele CCOE approved high pressure seamless BIS 7285 approved Cylinders having 55 ltr capacity, UL/FM/VDS approved FK5-1-12 clean agent gas with UL/FM/VDS listed valve assembly and electric solinoid switch. The system also to be fitted with low pressure supervisory switch for monitoring cylinder pressure gauge with safety burst disc safety cap, elbow and other accessories, mounting bracket, container straps, NRV , Pressure operated control head which shall allow for pressure actuation of gas mounted, manually operated actuator to actuate the gas flooding process with the help of a lever, flexible rubber hose with wire bralded enforcment to route the gas from the storage cyinder to the discharge piping, to be connected to the discharge outlet of gas cylinder valve & to be terminated at the system piping or discharge manifold, Flexible actuation hose complete as required. Discharge nozzle, 180/360 degree. Designated to provide proper flow rate & distribution FK5-1-12 gas to flood the hazard area as per latest NFPA 2001 requrement. Piping ASTM grade A 106 schedule 40 with fittings & supports and Gas Release Panel compatible to Fire Alarm System. (BATTERY ROOM-1)
1
-
-
TOTAL ROOM FLOODING SYSTEM
1x55 Itr completele CCOE approved high pressure seamless BIS 7285 approved Cylinders having 55 ltr capacity, UL/FM/VDS approved FK5-1-12 clean agent gas with UL/FM/VDS listed valve assembly and electric solinoid switch. The system also to be fitted with low pressure supervisory switch for monitoring cylinder pressure gauge with safety burst disc safety cap, elbow and other accessories, mounting bracket, container straps, NRV , Pressure operated control head which shall allow for pressure actuation of gas mounted, manually operated actuator to actuate the gas flooding process with the help of a lever, flexible rubber hose with wire bralded enforcment to route the gas from the storage cyinder to the discharge piping, to be connected to the discharge outlet of gas cylinder valve & to be terminated at the system piping or discharge manifold, Flexible actuation hose complete as required. Discharge nozzle, 180/360 degree. Designated to provide proper flow rate & distribution FK5-1-12 gas to flood the hazard area as per latest NFPA 2001 requrement. Piping ASTM grade A 106 schedule 40 with fittings & supports and Gas Release Panel compatible to Fire Alarm System. (SERVER ROOM-1)
1
-
-
TOTAL ROOM FLOODING SYSTEM
1x34 Itr completele CCOE approved high pressure seamless BIS 7285 approved Cylinders having 34 ltr capacity, UL/FM/VDS approved FK5-1-12 clean agent gas with UL/FM/VDS listed valve assembly and electric solinoid switch. The system also to be fitted with low pressure supervisory switch for monitoring cylinder pressure gauge with safety burst disc safety cap, elbow and other accessories, mounting bracket, container straps, NRV , Pressure operated control head which shall allow for pressure actuation of gas mounted, manually operated actuator to actuate the gas flooding process with the help of a lever, flexible rubber hose with wire bralded enforcment to route the gas from the storage cyinder to the discharge piping, to be connected to the discharge outlet of gas cylinder valve & to be terminated at the system piping or discharge manifold, Flexible actuation hose complete as required. Discharge nozzle, 180/360 degree. Designated to provide proper flow rate & distribution FK5-1-12 gas to flood the hazard area as per latest NFPA 2001 requrement. Piping ASTM grade A 106 schedule 40 with fittings & supports and Gas Release Panel compatible to Fire Alarm System. (UPS ROOM-2)
1
-
-