Chandrapur Cancer Care Foundation Tender
Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.
Chandrapur Cancer Care Foundation Tender
Electrical Goods and Equipments
Machinery and Tools
Electrical and Electronics
Eprocure
Opening Date13 Feb 2024
Closing Date29 Feb 2024
Tender Amount₹ 93,76,662 This is an estimated amount, exact amount may vary.
Costs
EMD
0Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_CHDPR_1003737_1Bid Award Id
ViewTender No
F4-CCCF/AC/2024Tender Authority
Chandrapur Cancer Care Foundation ViewPurchaser Address
-Website
http://mahatenders.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
AIR COOLED - SPLIT UNITS (Inverter Type)- UPS/SERVER/HUB ROOM
Supply, installation, testing and commissioning of INVERTER ROTARY TYPE / INVERTER SCROLL TYPE Air cooled DX, Split type air conditioning units each comprising of : An Oudoor unit and an Indoor unit can be: High wall type/Ductable, The unit shall be with R32 / R410 refrigerant.The split unit shall be only cooling or (Heat Pump) heating & cooling as mentioned below in the BOQ. The unit shall be with hand held IR remote or corded remote as may be required.The unit shall be with hand held IR remote or corded remote as may be required. Outdoor condensing unit shall comprise of single / multi inverter, rotary / scroll compressor & air cooled condenser with fan & motor. Evaporating unit shall consist of a blower section with dynamically balanced centrifugal blower driven by induction motor, multirows deep copper cooling coil with aluminium fins, thermostatic expansion valve etc. The evaporating unit shall be equipped with synthetic fibre filters, insulated drain pan, safety controls, thermostat all complete in a unit. Ductable units / Fured-in units shall have fire retardant canvass connection at fan outlet. The enclosure shall be factory painted to a smooth finish. The quoted price shall be inclusive of interconnected insulated refrigerant piping, insulated drain piping, vibration isolation pads / vibration isolators and associated electrical cabling & earthing between indoor & outdoor units and MS powder coated base frame work made of angle iron for mounting of outdoor / indoor units. The units shall be suitable for 230V±6%, or 415V±10%, 50 ± 3%,Hz supply & complete with electrical controls & panels, if required.
Hi wall units (Only Cooling) - (Noise Level 32-39 db) Hi wall Type -1.0 TR (470 CFM)(4W+0S) (RO)
1
-
-
AIR COOLED DUCTABLE SPLIT UNITS (High Static) Supply, installation, testing and commissioning of Split type air-conditioning unit, each comprising of an outdoor unit and a single ductable type /floor standing type indoor unit. Outdoor condensing unit shall comprise of single / multi, scroll compressor & air cooled condenser with fan & motor. Evaporating unit shall consist of a blower section with dynamically balanced centrifugal blower driven by induction motor, multirows deep copper cooling coil with aluminium fins, thermostatic expansion valve etc. The evaporating unit shall be equipped with synthetic fibre filters, insulated drain pan, safety controls, thermostat all complete in a unit. Ductable units shall have fire retardant canvass connection at fan outlet. The enclosure shall be factory painted to a smooth finish. The quoted price shall be inclusive of interconnected insulated refrigerant piping, insulated drain piping, vibration isolation pads / vibration isolators and associated electrical cabling & earthing between indoor & outdoor units and MS powder coated base frame work made of angle iron for mounting of outdoor / indoor units. The units shall be suitable for 230V±6%, or 415V±10%, 50 ± 3%,Hz supply & complete with electrical controls & panels.The unit shall be with R32 / R410 refrigerant. The split unit shall be only cooling or (Heat Pump) heating & cooling as mentioned below in the BOQ. The unit shall be with hand held corded remote . The Unit shall be complete with micro-processor based controller & shall be cable of BMS connectivity for operation & control through BMS. Ceiling Suspended Ductable Units(High Static ) - (ONLY COOLING) Ceiling Suspended Type 16.7 TR (5800-6600 CFM) ( 2W+2S )
6
-
-
AIR COOLED DUCTABLE SPLIT UNITS (High Static) Supply, installation, testing and commissioning of Split type air-conditioning unit, each comprising of an outdoor unit and a single ductable type /floor standing type indoor unit. Outdoor condensing unit shall comprise of single / multi, scroll compressor & air cooled condenser with fan & motor. Evaporating unit shall consist of a blower section with dynamically balanced centrifugal blower driven by induction motor, multirows deep copper cooling coil with aluminium fins, thermostatic expansion valve etc. The evaporating unit shall be equipped with synthetic fibre filters, insulated drain pan, safety controls, thermostat all complete in a unit. Ductable units shall have fire retardant canvass connection at fan outlet. The enclosure shall be factory painted to a smooth finish. The quoted price shall be inclusive of interconnected insulated refrigerant piping, insulated drain piping, vibration isolation pads / vibration isolators and associated electrical cabling & earthing between indoor & outdoor units and MS powder coated base frame work made of angle iron for mounting of outdoor / indoor units. The units shall be suitable for 230V±6%, or 415V±10%, 50 ± 3%,Hz supply & complete with electrical controls & panels.The unit shall be with R32 / R410 refrigerant. The split unit shall be only cooling or (Heat Pump) heating & cooling as mentioned below in the BOQ. The unit shall be with hand held corded remote . The Unit shall be complete with micro-processor based controller & shall be cable of BMS connectivity for operation & control through BMS. Ceiling Suspended Ductable Units(High Static ) - (ONLY COOLING) Ceiling Suspended Type 5.5 TR (2045 CFM) (RO)
1
-
-
AIR COOLED DUCTABLE SPLIT UNITS (High Static) Supply, installation, testing and commissioning of Split type air-conditioning unit, each comprising of an outdoor unit and a single ductable type /floor standing type indoor unit. Outdoor condensing unit shall comprise of single / multi, scroll compressor & air cooled condenser with fan & motor. Evaporating unit shall consist of a blower section with dynamically balanced centrifugal blower driven by induction motor, multirows deep copper cooling coil with aluminium fins, thermostatic expansion valve etc. The evaporating unit shall be equipped with synthetic fibre filters, insulated drain pan, safety controls, thermostat all complete in a unit. Ductable units shall have fire retardant canvass connection at fan outlet. The enclosure shall be factory painted to a smooth finish. The quoted price shall be inclusive of interconnected insulated refrigerant piping, insulated drain piping, vibration isolation pads / vibration isolators and associated electrical cabling & earthing between indoor & outdoor units and MS powder coated base frame work made of angle iron for mounting of outdoor / indoor units. The units shall be suitable for 230V±6%, or 415V±10%, 50 ± 3%,Hz supply & complete with electrical controls & panels.The unit shall be with R32 / R410 refrigerant. The split unit shall be only cooling or (Heat Pump) heating & cooling as mentioned below in the BOQ. The unit shall be with hand held corded remote . The Unit shall be complete with micro-processor based controller & shall be cable of BMS connectivity for operation & control through BMS. Ceiling Suspended Ductable Units(High Static ) - (ONLY COOLING) Ceiling Suspended Type 8.5 TR (3400 CFM) ( 1W+1S )(RO)
1
-
-
AIR COOLED DUCTABLE SPLIT UNITS (High Static) Supply, installation, testing and commissioning of Split type air-conditioning unit, each comprising of an outdoor unit and a single ductable type /floor standing type indoor unit. Outdoor condensing unit shall comprise of single / multi, scroll compressor & air cooled condenser with fan & motor. Evaporating unit shall consist of a blower section with dynamically balanced centrifugal blower driven by induction motor, multirows deep copper cooling coil with aluminium fins, thermostatic expansion valve etc. The evaporating unit shall be equipped with synthetic fibre filters, insulated drain pan, safety controls, thermostat all complete in a unit. Ductable units shall have fire retardant canvass connection at fan outlet. The enclosure shall be factory painted to a smooth finish. The quoted price shall be inclusive of interconnected insulated refrigerant piping, insulated drain piping, vibration isolation pads / vibration isolators and associated electrical cabling & earthing between indoor & outdoor units and MS powder coated base frame work made of angle iron for mounting of outdoor / indoor units. The units shall be suitable for 230V±6%, or 415V±10%, 50 ± 3%,Hz supply & complete with electrical controls & panels.The unit shall be with R32 / R410 refrigerant. The split unit shall be only cooling or (Heat Pump) heating & cooling as mentioned below in the BOQ. The unit shall be with hand held corded remote . The Unit shall be complete with micro-processor based controller & shall be cable of BMS connectivity for operation & control through BMS. Ceiling Suspended Ductable Units(High Static ) - (ONLY COOLING) Ceiling Suspended Type 11 TR (3850-4400 CFM) ( RO )
1
-
-
Packaged Floor Mounted Unit (High Static) - ( ONLY COOLING)
Floor Mounted Type Type 16.7 TR (5800-6600 CFM) ( 1W+1S )
Notes:- Hi-walls shall be with cordless remote.Final requirement on type of remotes shall be decided during execution stage. Tenderer to consider this fact in the costing.
2
-
-
Final requirement on type of remotes shall be decided during execution stage. Tenderer to consider this fact in the costing. Cordless Remotes Controller
22
-
-
Final requirement on type of remotes shall be decided during execution stage. Tenderer to consider this fact in the costing. Corded Remotes Controller
6
-
-
SEQUENTIAL CONTROLLER
Supply,installation,testing and commissioning of Sequential Controller for controlling Split Unit's. The controller shall ensure cyclic operation of AC units. It shall also have inbuilt temperature sensor & temperature display. Sequential Controller for (2W+1S) units (RO)
1
-
-
SEQUENTIAL CONTROLLER
Supply,installation,testing and commissioning of Sequential Controller for controlling Split Unit's. The controller shall ensure cyclic operation of AC units. It shall also have inbuilt temperature sensor & temperature display. Sequential Controller for (1W+1S) units
11
-
-
SEQUENTIAL CONTROLLER
Supply,installation,testing and commissioning of Sequential Controller for controlling Split Unit's. The controller shall ensure cyclic operation of AC units. It shall also have inbuilt temperature sensor & temperature display. Sequential Controller for (1W+1S) units (Ductable & Package AC)
3
-
-
ODU Anti Corrosive Coating
Carrying out Anti Corrosive coating through spray painting process on coil, fins, joints & header of each ODU as per paint manufacturer's recommendation including supply of paint:
Product: Promak Coating: Ultra Corr ACX 4000
For 16.7TR Ductable Split (RO)
1
-
-
ODU Anti Corrosive Coating
Carrying out Anti Corrosive coating through spray painting process on coil, fins, joints & header of each ODU as per paint manufacturer's recommendation including supply of paint:
Product: Promak Coating: Ultra Corr ACX 4000
For Hiwall Split Units (RO)
1
-
-
ODU Anti Corrosive Coating
Carrying out Anti Corrosive coating through spray painting process on coil, fins, joints & header of each ODU as per paint manufacturer's recommendation including supply of paint:
Product: Promak Coating: Ultra Corr ACX 4000
For 5.5 TR Ductable split(RO)
1
-
-
ODU Anti Corrosive Coating
Carrying out Anti Corrosive coating through spray painting process on coil, fins, joints & header of each ODU as per paint manufacturer's recommendation including supply of paint:
Product: Promak Coating: Ultra Corr ACX 4000
For 8.5 TR Ductable split(RO)
1
-
-
ODU Anti Corrosive Coating
Carrying out Anti Corrosive coating through spray painting process on coil, fins, joints & header of each ODU as per paint manufacturer's recommendation including supply of paint:
Product: Promak Coating: Ultra Corr ACX 4000
For 11 TR Ductable split(RO)
1
-
-
Refrigerant Piping
Supply, Installation, commisioning of Interconnecting refrigerant pipe work with closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specifications, all piping inside the room shall be properly supported with MS hanger & clamps. Exposed refrigerant copper piping shall be with uv coating. 34.9 mm O.D. (insulation : 13 mm)
160
-
-
Refrigerant Piping
Supply, Installation, commisioning of Interconnecting refrigerant pipe work with closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specifications, all piping inside the room shall be properly supported with MS hanger & clamps. Exposed refrigerant copper piping shall be with uv coating. 28.6 mm O.D. (insulation : 13 mm)
10
-
-
Refrigerant Piping
Supply, Installation, commisioning of Interconnecting refrigerant pipe work with closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specifications, all piping inside the room shall be properly supported with MS hanger & clamps. Exposed refrigerant copper piping shall be with uv coating. 22.2 mm O.D. (insulation : 13 mm)
10
-
-
Refrigerant Piping
Supply, Installation, commisioning of Interconnecting refrigerant pipe work with closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specifications, all piping inside the room shall be properly supported with MS hanger & clamps. Exposed refrigerant copper piping shall be with uv coating. 15.9 mm O.D. (insulation : 9 mm)
180
-
-
Refrigerant Piping
Supply, Installation, commisioning of Interconnecting refrigerant pipe work with closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specifications, all piping inside the room shall be properly supported with MS hanger & clamps. Exposed refrigerant copper piping shall be with uv coating. 12.7 mm O.D. (insulation : 9 mm)
100
-
-
Refrigerant Piping
Supply, Installation, commisioning of Interconnecting refrigerant pipe work with closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specifications, all piping inside the room shall be properly supported with MS hanger & clamps. Exposed refrigerant copper piping shall be with uv coating. 9.5 mm O.D. (insulation : 9 mm)
100
-
-
Refrigerant Piping
Supply, Installation, commisioning of Interconnecting refrigerant pipe work with closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specifications, all piping inside the room shall be properly supported with MS hanger & clamps. Exposed refrigerant copper piping shall be with uv coating. 6.4 mm O.D. (insulation : 9 mm)
120
-
-
CONDENSATE DRAIN PIPING
Supply,installation,testing and commissioning of rigid uPVC piping complete with fittings, supports as per specifications and duly insulated with 6 mm thick closed cell nitrile rubber. Density of uPVC pipe shall not be less than 10 kg / m3
25 mm NB
60
-
-
Supply installation, testing and commissioning of all control and data cables between indoor unit, outdoor unit and central remote controler laid in hard PVC conduit with proper supporting arrangement.
350
-
-
VRV UNITS FOR HUB ROOM - GF / FF /SF
Supply Installation, testing and commissioning of Variable Refrigerant System outdoor units with heat pump, with scroll compressors with all compressors with capacity controlling type compressor, copper tube and alumnium finned aircooled condenser, electrical & microprocessor panel, isolating valves and all the necessary accessories for proper functioning of the units. Refrigerant R-410a - Capacity - 16 HP (8+8)
1
-
-
Supply Installation, testing and commissioning of Variable Refrigerant System Hiwall type indoor units with copper tube and alumnium finned evaporator, and all the necessary accessories for proper functioning of the units. Capacity 2.0 TR
6
-
-
Supply installation , testing and commissioning of all refrigerant Joint Set of suction & liquid line required for the system to connect VRF Condensing Unit to multiple Indoor Units(IDU).
5
-
-
Testing & Commisioning charges alongwith topping-up of refrigerant for VRF system
1
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements