Chandrapur Cancer Care Foundation Tender

Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.

Chandrapur Cancer Care Foundation Tender

Works
Healthcare and Medicine
Chemical Products
Eprocure
Opening Date26 Oct 2023
Closing Date29 Nov 2023
Tender Amount₹ 2,99,28,890 
This is an estimated amount, exact amount may vary.
Notes
Download

Costs

Summary

C1_mgps/01-2023

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
OXYGEN SYSTEM Supply, Installation, Testing and Commissioning of fully Automatic Control Panel for secondary supply of Oxygen having a minimum flow output of over 1500 LPM at 4.2 bar pressure (imported certified complying to HTM 02-01 or DIN or NFPA 99C standards). As per Technical specification.

1

-

-

... More
OXYGEN SYSTEM Supply, Installation, Testing and commissioning of Emergency control panel with 2 Nos of High flow regulators (1500 LPM) and isolation valve for Oxygen having a constant flow output of over 1500 LPM at 4.2 bar pressure for emergency bank . (imported certified complying to HTM 02-01 or DIN or NFPA 99C standards). As per Technical specification.

1

-

-

... More
OXYGEN SYSTEM Supply, Installation, Testing and commissioning of Surface mounted front loading Oxygen outlets (Imported - first and second fix assembly) complying to HTM- 02-01 / NFPA 99C/ DIN standard with matching probe in SS 304.

240

-

-

... More
NITROUS OXIDE SYSTEM Supply, Installation, Testing and commissioning of 2 x 2 size manifold (Primary & Secondary supply) complete with middle frame with chain for individual cylinder (D type) along with Non Return Valves (NRV) for every cylinder with 4 nos.copper pig tail pipes. ( Imported ) (as per Technical specification)

1

-

-

... More
NITROUS OXIDE SYSTEM Supply, Installation, Testing and commissioning of 1 x 2 size manifold (Secondary supply) complete with middle frame with chain for individual cylinder (D Type ) along with Non Return Valves (NRV) for every cylinder along with high flow double stage Regulator and quick release and adopt mechanism using N20 with 2 nos. copper pig tail pipes. ( Imported ) (as per Technical specification)

1

-

-

... More
NITROUS OXIDE SYSTEM Supply, Installation, Testing and commissioning of Fully automatic control panel for N2O Having a min. flow output of over 500 LPM at 4.2 bar pressure (imported certified complying to HTM 02-01 or DIN or NFPA 99C standard) (As per Technical Specification)

1

-

-

... More
NITROUS OXIDE SYSTEM Supply, Installation, Testing and commissioning of Surface mounted front loading Nitrous Oxide outlets (first and second fix assembly) complying to HTM- 2022 / NFPA 99C/ DIN standard with matching probe.

18

-

-

... More
CARBON DIOXIDE SYSTEM Supply, Installation, Testing and commissioning of 1 x 2 size manifold (Primary & Secondary supply) complete with middle frame with chain for individual cylinder (VF size) along with Non Return Valves for every cylinder.with regulator (As per Technical Specification) ( Imported )

1

-

-

... More
CARBON DIOXIDE SYSTEM Supply, Installation, Testing and commissioning using a High Flow double stage regulator ( 2Nos) Having a min. flow output of over 500 LPM at 4.2 bar pressure.

1

-

-

... More
CARBON DIOXIDE SYSTEM Supply, Installation, Testing and commissioning of Surface mounted front loading CO2 outlets (first and second fix assembly) complying to HTM- 02-01 / NFPA 99C/ DIN standard with matching probe. As per Technical Specification.

4

-

-

... More
COMPRESSED AIR SYSTEM Supply, Installation, Testing and commissioning of Triplex Air compressor (Imported) with 3 Stage Air Filtration system and reducing station Duplex Air Dryer (Imported) with Tank of 2 x 2000 LTR (Indigenous) As per Technical specification ( Note-complete package with Air Compressors : 03 Nos)

1

-

-

... More
COMPRESSED AIR SYSTEM Supply, Installation, Testing and commissioning of Surface mounted front loading double locked outlets (first and second fix assembly) Complying to HTM- 02-01/ NFPA 99C/DIN standard with probe for MA 4 & SA 7Gas Outlet Points/ Terminal Units (Imported ) (As per Technical Specification) a) Medical Air-4 bar (Imported)

60

-

-

... More
COMPRESSED AIR SYSTEM Supply, Installation, Testing and commissioning of Surface mounted front loading double locked outlets (first and second fix assembly) Complying to HTM- 02-01/ NFPA 99C/DIN standard with probe for MA 4 & SA 7Gas Outlet Points/ Terminal Units (Imported ) (As per Technical Specification) b) Surgical Air-7 bar (Imported)

15

-

-

... More
VACCUM SYSTEM Supply, Installation, Testing and commissioning of Triplex vacuum compressor with Bacteria filter (Imported) Silencer and Tank.of 2 x 2000 LTR (Indigenous) As per technical specification( Note-complete package with Vacuum Pump : 3 Nos )

1

-

-

... More
VACCUM SYSTEM Supply, Installation, Testing and commissioning of Surface mounted front loading FVacuum out lets, (first and second fix assembly)Complying to HTM- 2022/ NFPA 99/ DIN standard with matching probe Gas Outlet Points/ Terminal Units (Imported ) (As per Technical Specification)

240

-

-

... More
Electrical Control Panel Supply, Installation, Testing and commissioning of combined Electrical Control Panel for compressed air system and Vacuum System & complete with plant Room wiring. The panel should have energy and running hours meter. As per technical specification NOTE- MGPS panel should have dual incomer provision with ASCO make automatic transfer switch (ATS) also outgoing feeder for AGSS panel and single phase suitable power provision for MGPS control panel , alarm panel ,dryer etc asper OEM requirement , vendor should submit panel GA dwg along with BOM before production of panel

1

-

-

... More
ANESTHETIC GAS SCAVENGING SYSTEM (AGSS) Supply, Installation, Testing and commissioning of Duplex AGSS System (Imported ) should include required components in order to connect the Anaesthesia workstation of Dragger Make (Model- Fabius XL) to the central AGSS system. (As per Technical Specification).

1

-

-

... More
ANESTHETIC GAS SCAVENGING SYSTEM (AGSS) Supply, Installation, Testing and commissioning of AGSS terminal unit (first and second fix assembly)Complying to HTM- 02-01/ NFPA 99/DIN standard with probe for AGSS

5

-

-

... More
MEDICAL GAS PIPE LINE , PIPELINE DISTRIBUTION SYSTEM: Supply, Installation, Testing and commissioning of Copper Pipe 'Lloyd Certified' for medical gas services. Pipes shall be priced for all necessary supports, standard fittings.MEDICAL GAS PIPE LINE : BS EN: 13348:2001Supply,Instllation and commissioning of Copper Piping as per specification 12 mm OD x 1 mm thick

937

-

-

... More
MEDICAL GAS PIPE LINE , PIPELINE DISTRIBUTION SYSTEM: Supply, Installation, Testing and commissioning of Copper Pipe 'Lloyd Certified' for medical gas services. Pipes shall be priced for all necessary supports, standard fittings.MEDICAL GAS PIPE LINE : BS EN: 13348:2001Supply,Instllation and commissioning of Copper Piping as per specification 15 mm OD x 1mm thick

2962

-

-

... More
MEDICAL GAS PIPE LINE , PIPELINE DISTRIBUTION SYSTEM: Supply, Installation, Testing and commissioning of Copper Pipe 'Lloyd Certified' for medical gas services. Pipes shall be priced for all necessary supports, standard fittings.MEDICAL GAS PIPE LINE : BS EN: 13348:2001Supply,Instllation and commissioning of Copper Piping as per specification 22 mm OD x 1 mm thick

1597

-

-

... More
MEDICAL GAS PIPE LINE , PIPELINE DISTRIBUTION SYSTEM: Supply, Installation, Testing and commissioning of Copper Pipe 'Lloyd Certified' for medical gas services. Pipes shall be priced for all necessary supports, standard fittings.MEDICAL GAS PIPE LINE : BS EN: 13348:2001Supply,Instllation and commissioning of Copper Piping as per specification 28 mm OD x 1 mm thick

988

-

-

... More
MEDICAL GAS PIPE LINE , PIPELINE DISTRIBUTION SYSTEM: Supply, Installation, Testing and commissioning of Copper Pipe 'Lloyd Certified' for medical gas services. Pipes shall be priced for all necessary supports, standard fittings.MEDICAL GAS PIPE LINE : BS EN: 13348:2001Supply,Instllation and commissioning of Copper Piping as per specification 35mm OD X 1.2 mm thick

98

-

-

... More
MEDICAL GAS PIPE LINE , PIPELINE DISTRIBUTION SYSTEM: Supply, Installation, Testing and commissioning of Copper Pipe 'Lloyd Certified' for medical gas services. Pipes shall be priced for all necessary supports, standard fittings.MEDICAL GAS PIPE LINE : BS EN: 13348:2001Supply,Instllation and commissioning of Copper Piping as per specification 42 mm OD x 1.2 mm thick

343

-

-

... More
MEDICAL GAS PIPE LINE , PIPELINE DISTRIBUTION SYSTEM: Supply, Installation, Testing and commissioning of Copper Pipe 'Lloyd Certified' for medical gas services. Pipes shall be priced for all necessary supports, standard fittings.MEDICAL GAS PIPE LINE : BS EN: 13348:2001Supply,Instllation and commissioning of Copper Piping as per specification 54 mm OD x 1.2 mm thick

284

-

-

... More
MEDICAL GAS PIPE LINE , PIPELINE DISTRIBUTION SYSTEM: Supply, Installation, Testing and commissioning of Copper Pipe 'Lloyd Certified' for medical gas services. Pipes shall be priced for all necessary supports, standard fittings.MEDICAL GAS PIPE LINE : BS EN: 13348:2001Supply,Instllation and commissioning of Copper Piping as per specification 76 mm OD x 1.5 mm thick

142

-

-

... More
MEDICAL GAS PIPE LINE , PIPELINE DISTRIBUTION SYSTEM: Supply, Installation, Testing and commissioning of Copper Pipe 'Lloyd Certified' for medical gas services. Pipes shall be priced for all necessary supports, standard fittings.MEDICAL GAS PIPE LINE : BS EN: 13348:2001Supply,Instllation and commissioning of Copper Piping as per specification 108 mm OD x 1.5 mm thick

18

-

-

... More
Isolation Valve /Floor valve (Imported ) as per specification Supply, Installation, Testing and commissioning of Isolation Valve assembly as per HTM/ EN for medical gas services, provision for locking type assembly. All valve should be gas specific. (Imported ) as per specification 15 mm

32

-

-

... More
Isolation Valve /Floor valve (Imported ) as per specification Supply, Installation, Testing and commissioning of Isolation Valve assembly as per HTM/ EN for medical gas services, provision for locking type assembly. All valve should be gas specific. (Imported ) as per specification 22 mm

36

-

-

... More
Isolation Valve /Floor valve (Imported ) as per specification Supply, Installation, Testing and commissioning of Isolation Valve assembly as per HTM/ EN for medical gas services, provision for locking type assembly. All valve should be gas specific. (Imported ) as per specification 28 mm

18

-

-

... More
Isolation Valve /Floor valve (Imported ) as per specification Supply, Installation, Testing and commissioning of Isolation Valve assembly as per HTM/ EN for medical gas services, provision for locking type assembly. All valve should be gas specific. (Imported ) as per specification 35 mm

6

-

-

... More
Isolation Valve /Floor valve (Imported ) as per specification Supply, Installation, Testing and commissioning of Isolation Valve assembly as per HTM/ EN for medical gas services, provision for locking type assembly. All valve should be gas specific. (Imported ) as per specification 42 mm

14

-

-

... More
Isolation Valve /Floor valve (Imported ) as per specification Supply, Installation, Testing and commissioning of Isolation Valve assembly as per HTM/ EN for medical gas services, provision for locking type assembly. All valve should be gas specific. (Imported ) as per specification 54 mm

14

-

-

... More
Isolation Valve /Floor valve (Imported ) as per specification Supply, Installation, Testing and commissioning of Isolation Valve assembly as per HTM/ EN for medical gas services, provision for locking type assembly. All valve should be gas specific. (Imported ) as per specification 76 mm

5

-

-

... More
Isolation Valve /Floor valve (Imported ) as per specification Supply, Installation, Testing and commissioning of Isolation Valve assembly as per HTM/ EN for medical gas services, provision for locking type assembly. All valve should be gas specific. (Imported ) as per specification 108 mm

5

-

-

... More
AREA VALVE SERVICE UNIT (AVSU) (Imported ) (As per Technical Specification) Supply and installation of AVSU box with all its accessories with valve and pressure / vacuum gauges, NIST connectors with lockable arrangement and breakable glass cover. (Imported ) (As per Technical Specification) 2 valve configuration with 15 O2, 28 VAC

13

-

-

... More
AREA VALVE SERVICE UNIT (AVSU) (Imported ) (As per Technical Specification) Supply and installation of AVSU box with all its accessories with valve and pressure / vacuum gauges, NIST connectors with lockable arrangement and breakable glass cover. (Imported ) (As per Technical Specification) 3 valve configuration 15 O2, 15 MA4, 28 VAC

7

-

-

... More
AREA VALVE SERVICE UNIT (AVSU) (Imported ) (As per Technical Specification) Supply and installation of AVSU box with all its accessories with valve and pressure / vacuum gauges, NIST connectors with lockable arrangement and breakable glass cover. (Imported ) (As per Technical Specification) 3 valve configuration 15 O2, 22 MA4, 28 VAC

1

-

-

... More
AREA VALVE SERVICE UNIT (AVSU) (Imported ) (As per Technical Specification) Supply and installation of AVSU box with all its accessories with valve and pressure / vacuum gauges, NIST connectors with lockable arrangement and breakable glass cover. (Imported ) (As per Technical Specification) 4 valve configuration 15 O2, 15 N2O, 15 MA4, 28 VAC

6

-

-

... More
AREA VALVE SERVICE UNIT (AVSU) (Imported ) (As per Technical Specification) Supply and installation of AVSU box with all its accessories with valve and pressure / vacuum gauges, NIST connectors with lockable arrangement and breakable glass cover. (Imported ) (As per Technical Specification) 5 valve configuration 15 O2, 15 N2O, 15 MA4, 15 SA7, 28 VAC

4

-

-

... More
AREA VALVE SERVICE UNIT (AVSU) (Imported ) (As per Technical Specification) Supply and installation of AVSU box with all its accessories with valve and pressure / vacuum gauges, NIST connectors with lockable arrangement and breakable glass cover. (Imported ) (As per Technical Specification) 6 valve configuration 15 O2, 15 N2O, 15 MA4, 15 SA7, 22 VAC, 15 CO2

3

-

-

... More
AREA VALVE SERVICE UNIT (AVSU) (Imported ) (As per Technical Specification) Supply and installation of AVSU box with all its accessories with valve and pressure / vacuum gauges, NIST connectors with lockable arrangement and breakable glass cover. (Imported ) (As per Technical Specification) 2 valve configuration with 15 O2, 15 VAC (for pre, 3rdfloor 2nos isolation room , post procedure )-optional [QRO]

1

-

-

... More
AREA VALVE SERVICE UNIT (AVSU) (Imported ) (As per Technical Specification) Supply and installation of AVSU box with all its accessories with valve and pressure / vacuum gauges, NIST connectors with lockable arrangement and breakable glass cover. (Imported ) (As per Technical Specification) 2 valve configuration with 15 O2, 15 VAC (for pre, 3rdfloor 2nos isolation room ,post procedure ) optional [QRO]

1

-

-

... More
AREA VALVE SERVICE UNIT (AVSU) (Imported ) (As per Technical Specification) Supply and installation of AVSU box with all its accessories with valve and pressure / vacuum gauges, NIST connectors with lockable arrangement and breakable glass cover. (Imported ) (As per Technical Specification) 3 valve configuration with 15 O2, 15 MA4,15 VAC (for post) optional [QRO]

1

-

-

... More
AREA VALVE SERVICE UNIT (AVSU) (Imported ) (As per Technical Specification) Supply and installation of AVSU box with all its accessories with valve and pressure / vacuum gauges, NIST connectors with lockable arrangement and breakable glass cover. (Imported ) (As per Technical Specification) 3 valve configuration 15 O2, 15 MA4, 22 VAC (for recliners bed) optional [QRO]

1

-

-

... More
AREA VALVE SERVICE UNIT (AVSU) (Imported ) (As per Technical Specification) Supply and installation of AVSU box with all its accessories with valve and pressure / vacuum gauges, NIST connectors with lockable arrangement and breakable glass cover. (Imported ) (As per Technical Specification) 3 valve configuration 35 O2, 28 MA4, 42 VAC(for ICU ) optional [QRO]

1

-

-

... More
AREA VALVE SERVICE UNIT (AVSU) (Imported ) (As per Technical Specification) Supply and installation of AVSU box with all its accessories with valve and pressure / vacuum gauges, NIST connectors with lockable arrangement and breakable glass cover. (Imported ) (As per Technical Specification) 4 valve configuration 22 O2, 15 N2O, 15 MA4, 28 VAC (for first floor dental area ) optional [QRO]

1

-

-

... More
AREA VALVE SERVICE UNIT (AVSU) (Imported ) (As per Technical Specification) Supply and installation of AVSU box with all its accessories with valve and pressure / vacuum gauges, NIST connectors with lockable arrangement and breakable glass cover. (Imported ) (As per Technical Specification) 4 valve configuration 15 O2, 15 N2O, 15 MA4, 22 VAC (for RT ) optional [QRO]

1

-

-

... More
AREA VALVE SERVICE UNIT (AVSU) (Imported ) (As per Technical Specification) Supply and installation of AVSU box with all its accessories with valve and pressure / vacuum gauges, NIST connectors with lockable arrangement and breakable glass cover. (Imported ) (As per Technical Specification) 4 valve configuration 15 O2, 15 N2O, 15 MA4, 15 VAC(for minor OT, procedure room) optional [QRO]

1

-

-

... More
MEDICAL GAS AREA ALARM PANEL (Imported ) (As per Technical Specification). ALARM SYSTEM : Providing and fixing alarm system for Medical gas system complete consisting of pressure sensors, panel and the control cabling, all wiring shall be within 1mm sq multi core data cable, PVC pipe for data cable. Panel shall be self-contained low voltage (less than 24 V) (Imported ) (As per Technical Specification). 2 Gas

5

-

-

... More
MEDICAL GAS AREA ALARM PANEL (Imported ) (As per Technical Specification). ALARM SYSTEM : Providing and fixing alarm system for Medical gas system complete consisting of pressure sensors, panel and the control cabling, all wiring shall be within 1mm sq multi core data cable, PVC pipe for data cable. Panel shall be self-contained low voltage (less than 24 V) (Imported ) (As per Technical Specification). 3 Gas

5

-

-

... More
MEDICAL GAS AREA ALARM PANEL (Imported ) (As per Technical Specification). ALARM SYSTEM : Providing and fixing alarm system for Medical gas system complete consisting of pressure sensors, panel and the control cabling, all wiring shall be within 1mm sq multi core data cable, PVC pipe for data cable. Panel shall be self-contained low voltage (less than 24 V) (Imported ) (As per Technical Specification). 4 Gas

5

-

-

... More
MEDICAL GAS AREA ALARM PANEL (Imported ) (As per Technical Specification). ALARM SYSTEM : Providing and fixing alarm system for Medical gas system complete consisting of pressure sensors, panel and the control cabling, all wiring shall be within 1mm sq multi core data cable, PVC pipe for data cable. Panel shall be self-contained low voltage (less than 24 V) (Imported ) (As per Technical Specification). 5 Gas [QRO]

1

-

-

... More
MEDICAL GAS AREA ALARM PANEL (Imported ) (As per Technical Specification). ALARM SYSTEM : Providing and fixing alarm system for Medical gas system complete consisting of pressure sensors, panel and the control cabling, all wiring shall be within 1mm sq multi core data cable, PVC pipe for data cable. Panel shall be self-contained low voltage (less than 24 V) (Imported ) (As per Technical Specification). 6 Gas

3

-

-

... More
Alarm System- Master Alarm Control Panel Supply, Installation and commissioning of master alarms should be capable to monitor followings gases in Manifold and plant Room 1. Liquid oxygen line pressure 2.Oxygen Manifold (Secondary Supply) Bank pressure 3. Emergency O2 Bank pressure 4. N2O (Primary Supply) Bank Pressure 5. N2O Emergency Bank pressure 6. Air 4 Bar line Pressure 7. Air 7 bar line pressure 8. Vacuum line pressure 9. Co2 manifold bank pressure 10. AGSS line pressure 11. All the Control Alarm line pressure. The system should EU CE under class II A category having 4 digit no from notified body / American UL Listed /American EL listed. The Master Alarm should display numeric values of all positive and negative gas pressures along LED Indicator.It should capable to display the pressure of each gas along with fault and pressure High/ Low alarm with indication. It should capable to Intergrade with the Hospital BMS system compatible with BacNet / Modbus.

1

-

-

... More
Bed Head Panel Supply, Installation, Testing and commissioning of Bed head panel.of 1.2 mt. Switch & Socket-3, Nursecall1no Only cutout,Data & Telephone .Cut out for Outlet (2/3 outlet) Nurse cal.as per specification.(indigenous) - Confirming HTM 02-01, NFPA 99C or equivalent.

114

-

-

... More
Supply, Installation, Testing and commissioning of Bed head panel. Bed head panel of 1.8 mt. Switch & Socket-6, Nursecall1no Only cutout,Data & Telephone .Cut out for Outlet (4/5 outlet) Nurse cal.as per specification.(Indigenous) Confirming HTM 02-01, NFPA 99C or equivalent.

31

-

-

... More
ACCESSORIES:- OXYGEN FLOW METER & HUMIDIFIER BOTTLE (Indigenous) : Back Pressure Compensated Flow meter shall be of accurate gas flow measurement and control within a range of 0-15 liters per minute for use in a variety of respiratory therapy gas delivery system. The flow tube and shroud components shall be made of good quality plastic. They shall be supplied with plastic transparent reusable humidifier

171

-

-

... More
ACCESSORIES:- WARD VACUUM UNITS (Indigenous) : The vacuum unit shall include vacuum regulator along with 0-760 mm Hg vacuum gauge of 2 ½ size dial, 600 ml capacity reusable plastic collection bottle with overflow safety trap with plastic slide wall mounted type..as per specification.

131

-

-

... More
ACCESSORIES:- The vacuum unit shall include vacuum regulator along with 0-760 mm of Hg vacuum gauge of 1000 ml capacity reusable plastic collection bottle with overflow safety trap with plastic slide wall mounted type as per specification.

37

-

-

... More
ACCESSORIES:- THEATRE VACUUM UNITI : It shall be trolley mounted. The unit shall include one regular having gauge and mounted on the trolley stand, having two reusable each 2000 ml plastic collection bottles mounted on the base of trolley unit and connected with regulator & low pressure tube inter-connections.(As per Technical Specification).

7

-

-

... More
ACCESSORIES:- Supply installation testing and commissioning of Medical gas hose assemblies Hoses shall be color coded throughout their length as specified in British standards. 50m for O2, 60m Air 100m Vaccum 15m for Co2, 15m for AGSS, 30m N2O.( Imported)

300

-

-

... More
ACCESSORIES:- Double stage Pressure Regulator

20

-

-

... More
ACCESSORIES:- Emergency control panel ( with 2 high flow regulator and 2) isolation valves

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.