Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.

Central Railway - CR Tender

Works
Electrical Works
Ireps
Opening Date3 Mar 2025
Closing Soon8 Apr 2025
Tender Amount₹ 57,52,347.4 
Notes
Download

Costs

Summary

Design, Supply, Erection Testing And Commissioning Of 25 Kv, Single Phase, Ac ohe Works, In Connection With Following Works : (1)raver Station- construction/extension Of Track Machine

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Preparation of design & drawing for overhead equipment 5

-

72960

72960

... More
Supply of galvanized steel for structure 6

10

120464

1204640

... More
Erection of galvanized steel for structure 7

7

7690

53830

... More
Manual / with Road Crane Erection of Portal / TTC boom 8

3

10556

31668

... More
Supply of galvanized small parts steel (SPS).

1.5

120832

181248

... More
Erection of galvanized small parts steel (SPS).

1.5

8103

12154.5

... More
Supply of a single bracket/cantilever assembly suitable for Coventional type OHE with bracket and stay porcelain insulators.

15

22021

330315

... More
Erection of a single bracket/cantilever assembly suitable for Coventional type OHE with bracket and stay porcelain insulators.

15

850

12750

... More
Supply of Hard drawn round copper for dropper wire, diameter 5 mm as per IS:282:1982.

20

795

15900

... More
Supply Contact wire Dropper clip (107) with locking wire as per RDSO Drawing no. RE/33/P/1181 Rev. G or latest.

64

100

6400

... More
Supply 65 Sq.mm copper catenary dropper clip assembly consisting of catenary clip SS bolt M-10X30X35mm (10/16), spring washer B-10, Split pin 2.5X20mm, as per RDSO Drg. No. ETI/OHE/P/1192 Mod. C or latest.

100

69

6900

... More
Fabrication & erection of dropper assembly (Conventional OHE) including removal of old droppering. 16

100

74

7400

... More
Manual erection of overhead equipment (Conventional type).

0.2

-

7634.6

... More
Supply of Contact wire splice (toothed type) complete with stainless steel stud bolt M- 12, 25/20, as per RDSO drg. No. ETI/OHE/P/1080-1 Mod-'C' 18

4

1892

7568

... More
Supply of Catenary Splice (65) as per RDSO drg. No. ETI/OHE/O/1090 or latest. 19

4

981

3924

... More
Splicing & extension of anchored over head equipment. 20

4

2134

8536

... More
Supply of OHE termination assembly Conventional type (including insulators) 21

2

8841

17682

... More
Erection of OHE termination assembly Conventional type (including insulators) 22

2

1599

3198

... More
Supply of 3 pulley type ATD assembly for Conventional type OHE. 23

1

76601

76601

... More
Erection of 3 pulley type ATD assembly for Conventional type OHE. 24

1

3475

3475

... More
Supply of OHE termination assembly tramway type (including insulators) 25

1

7772

7772

... More
Erection of OHE termination assembly tramway type (including insulators) 26

1

1413

1413

... More
Supply of 3 pulley type ATD assembly for Tramway type OHE. 27

1

48354

48354

... More
Erection of 3 pulley type ATD assembly for Tramway type OHE. 28

1

2626

2626

... More
Erection of anti creep arrangement (Excluding materials). 29

1

4338

4338

... More
Supply of guy rod assembly 30

2

7729

15458

... More
Erection of guy rod assembly 31

2

507

1014

... More
Supply of single earth electrode 32

5

3684

18420

... More
Erection of single earth electrode

5

901

4505

... More
Supply sectioning insulators & porcelain 9-tonne insulators suitable for conventional type OHEof section insulator assembly along with all fittings including Porcelain

1

46884

46884

... More
Erection of section insulator assembly along with all fittings including Porcelain sectioning insulators & porcelain 9-tonne insulators suitable for conventional type OHE

1

3318

3318

... More
Supply of 25 KV 1600 A single pole isolator assembly with insulators and pad lock (03 keys) 36

1

83905

83905

... More
Supply of Integral lock for Isolator with 02 nos key. 37

1

1735

1735

... More
Erection of 25 KV 1600 A single pole isolator assembly with insulators 38

1

5379

5379

... More
Supply of 25 KV Post Insulator 39

2

5902

11804

... More
Erection of 25 KV Post Insulator

2

885

1770

... More
Supply of Porcelain 9 Tonne Insulator RI-6020-I (Minimum CD 1050 mm) conforming to RDSO Specification no.TI/SPC/OHE/ INS/0070 (04/2007) with A & C Slip no. 1 & 2 or latest for Cut- in insulator/suspension.

2

2885

5770

... More
Supply of Contact Wire Ending Clamp (107) as per ID no. 1110-2 & DRG.No ETI/OHE/1110-2 each set comprising of 01 no contact wire ending clamp body part no. 1118. 01 No contact wire ending clamp wedge part no. 1119 for Cut- in Insulator/ suspension.

4

354

1416

... More
Supply of Catenary Wire Ending Clamp (65 Sq.mm) Part No. 1121, 1092 &1094, with fasteners as per Drg NO.ETI/OHE/P/ 1120 Rev-B or Latest for Cut- in insulator/suspension. 43

4

531

2124

... More
Erection of cut-in insulator assembly. 44

2

671

1342

... More
Supply of Copper jumper wire (160 sq mm) 45

20

1168

23360

... More
Supply of P.G.Clamp (1030-3) complete assembly

8

241

1928

... More
Erection of any type jumper assembly such as "G" jumper, AT jumper, Isolator jumper etc (Excluding material) 47

2

423

846

... More
Supply of various types of Galvanized traction bonds 40x6 mm. 48

200

188

37600

... More
Erection of various types of Galvanized traction bonds 40x6 mm. 49

200

49

9800

... More
Supply of Retro reflective type Location number plates. 50

50

406

20300

... More
Erection of Retro reflective type Location number plates. 51

50

81

4050

... More
Supply of Caution board for 25 KV AC electrified area as per RDSO Drawing. 52

5

372

1860

... More
Erection of Caution board for 25 KV AC electrified area as per RDSO Drawing. 53

5

81

405

... More
Painting of "OHE parameters" on OHE structures as per Drwaing No. - BSL/TD/SK-441

20

56

1120

... More
Painting of "Location Numbers" on backside of OHE structures as per Drawing no. BSL/TD/SK-424

20

46

920

... More
Painting of counter weight of ATD by silver paint & painting of location number on bottom 3 pieces of counter weight with similer colour of enamelled number plate.

5

346

1730

... More
Transfer of equipment from one mast or support to another including old bracket removal.

15

3293

49395

... More
Dismantling of OHE termination assembly 58

-

-

57

... More
Dismantling of any type of ATD 59

2

2377

4754

... More
Dismantling of anti creep arrangement 60

1

1772

1772

... More
Dismantling of guy rod assembly 61

3

507

1521

... More
Dismantling of section insulator assembly 62

1

2996

2996

... More
Dismantling of single pole isolator assembly including SPS 63

1

2996

2996

... More
Dismantling of cut-in insulator assembly.

2

564

1128

... More
Dismantling OHE structures by cutting and transporting to Railway depot including loading and unloading. 65

2

5913

11826

... More
Mannual /with Road crane dismantling of Portal / TTC boom 66

0.5

-

5278

... More
Breaking of foundation

5

4112

20560

... More
100% extra on erection charges for power block work for Erection of galvanised steel for structures 68

7

7690

53830

... More
100% extra on erection charges for power block work for Erection of Portal / TTC boom

3

10556

31668

... More
100% extra on erection charges for power block work for Erection of galvanised small parts steel (SPS).

1.5

8103

12154.5

... More
100% extra on erection charges for power block work for Erection of cantilever assembly (Conventional Type, including insulator)

15

850

12750

... More
100% extra on erection charges for power block work for Fabrication & erection of dropper assembly (Conventional OHE) including removal of old droppering.

100

74

7400

... More
100% extra on erection charges for power block work for Manual erection of overhead equipment (Conventional type).

0.2

-

7634.6

... More
100% extra on erection charges for power block work for Splicing & extention of anchored over head equipment.

4

2134

8536

... More
100% extra on erection charges for power block work for Erection OHE termination assembly Conventional type including porcelain 9-tonne insulators.

2

1599

3198

... More
100% extra on erection charges for power block work for Erection of 3 pulley type ATD for Conventation OHE

1

3475

3475

... More
100% extra on erection charges for power block work for Erection OHE termination assembly Tramway type including porcelain 9-tonne insulators.

1

1413

1413

... More
100% extra on erection charges for power block work for Erection of 3 pulley type ATD for Tramway OHE

1

2626

2626

... More
100% extra on erection charges for power block work for Erection of anticreep arrangement (Excluding materials).

1

4338

4338

... More
100% extra on erection charges for power block work Erection of Section Insulatorassembly for Conventional OHE

1

3318

3318

... More
100% extra on erection charges for power block work Erection of 25 KV 1600 A single pole isolator assembly with insulators

1

5379

5379

... More
100% extra on erection charges for power block work for erection of cut-in insulator assembly.

2

671

1342

... More
100% extra on erection charges for power block work for Erection of any type jumper assembly such as "G" jumper, AT jumper, Isolator jumper etc.

2

423

846

... More
100% extra on erection charges for power block work for Transfer of equipment from one mast or support to another including old bracket removal.

15

3293

49395

... More
100% extra on erection charges for power block work for Dismantling of OHE termination assembly

3

758

2274

... More
100% extra on erection charges for power block work for Dismantling of any type of ATD assembly

2

2377

4754

... More
100% extra on erection charges for power block work for Dismantling of anticreep arrangement (Excluding materials).

1

1772

1772

... More
100% extra on erection charges for power block work for Dismantling of section insulator assembly

1

2996

2996

... More
100% extra on erection charges for power block work for Dismantling of single pole isolator assembly including SPS

1

2996

2996

... More
100% extra on erection charges for power block work for Dismantling of cut-in insulator assembly for contact wire/ catenary wire

2

564

1128

... More
100% extra on erection charges for power block work for Dismantling of Portal/TTC boom

0.5

-

5278

... More
Digging, casting, grouting and muffing of foundation including cost of cement and material in other than hard & rocky soil (Foundation should be M-15 type as per IS-456, i.e ratio 1:2:4).

30

6110

183300

... More
Digging, casting, grouting and muffing of foundation including cost of cement and material in hard & rocky soil (Foundation should be M-15 type as per IS-456, i.e ratio 1:2:4). 3

8

6784

54272

... More
Preparation / raising of muff of OHE foundation 4 4.00 Per Track

10

5467

54670

... More
Preparation of design & drawing for overhead equipment 5

-

72960

72960

... More
Supply of galvanized steel for structure 6

5

120464

602320

... More
Erection of galvanized steel for structure 7

5

7690

38450

... More
Supply of galvanized small parts steel (SPS). 8

1

120832

120832

... More
Erection of galvanized small parts steel (SPS).

1

8103

8103

... More
Supply of a single bracket/cantilever assembly suitable for Coventional type OHE with 1050 mm long Creepage Distance bracket and stay porcelain insulators.

10

22021

220210

... More
Erection of a single bracket/cantilever assembly suitable for Coventional type OHE with 1050 mm long Creepage Distance bracket and stay porcelain insulators.

10

850

8500

... More
Supply of Hard drawn round copper for dropper wire, diameter 5 mm as per IS:282:1982.

30

795

23850

... More
Supply Contact wire Dropper clip (107) with locking wire as per RDSO Drawing no. RE/33/P/1181 Rev. G or latest.

120

64

7680

... More
Supply 65 Sq.mm copper catenary dropper clip assembly consisting of catenary clip SS bolt M-10X30X35mm (10/16), spring washer B-10, Split pin 2.5X20mm, as per RDSO Drg. No. ETI/OHE/P/1192 Mod. C or latest.

120

69

8280

... More
Fabrication & erection of dropper assembly (Conventional OHE) including removal of old droppering. 15

120

74

8880

... More
Manual erection of overhead equipment (Conventional type). 16

0.2

-

7634.6

... More
Supply of OHE termination assembly Conventional type (including insulators) 17

2

8841

17682

... More
Erection of OHE termination assembly Conventional type (including insulators) 18

2

1599

3198

... More
Supply of 3 pulley type ATD assembly for Conventional type OHE. 19

2

76601

153202

... More
Erection of 3 pulley type ATD assembly for Conventional type OHE. 20

2

3475

6950

... More
Supply of guy rod assembly 21

2

7729

15458

... More
Erection of guy rod assembly 22

2

507

1014

... More
Supply of single earth electrode 23

6

3684

22104

... More
Erection of single earth electrode 24

6

901

5406

... More
Supply of Copper jumper wire (160 sq mm) 25

15

1143

17145

... More
Supply of P.G.Clamp (1030-3) complete assembly

16

313

5008

... More
Erection of any type jumper assembly such as "G" jumper, AT jumper, Isolator jumper etc (Excluding material) 27

2

423

846

... More
Supply of various types of Galvanized traction bonds 40x6 mm. 28

200

188

37600

... More
Erection of various types of Galvanized traction bonds 40x6 mm. 29

200

49

9800

... More
Supply of Retro reflective type Location number plates. 30

20

406

8120

... More
Erection of Retro reflective type Location number plates. 31

20

81

1620

... More
Supply of Caution board for 25 KV AC electrified area as per RDSO Drawing. 32

6

372

2232

... More
Erection of Caution board for 25 KV AC electrified area as per RDSO Drawing. 33

6

74

444

... More
Painting of "OHE parameters" on OHE structures as per Drwaing No. - BSL/TD/SK-441

20

56

1120

... More
Painting of "Location Numbers" on backside of OHE structures as per Drawing no. BSL/TD/SK-424

-

-

34

... More
Painting of counter weight of ATD by silver paint & painting of location number on bottom 3 pieces of counter weight with similer colour of enamelled number plate.

2

346

692

... More
Transfer of equipment from one mast or support to another including old bracket removal. 37

10

3293

32930

... More
Dismantling of OHE termination assembly 38

2

758

1516

... More
Dismantling of any type of ATD 39

2

2377

4754

... More
Dismantling of guy rod assembly

2

507

1014

... More
Dismantling OHE structures by cutting and transporting to Railway depot including loading and unloading. 41

4

5913

23652

... More
Breaking of foundation

4

4112

16448

... More
100% extra on erection charges for power block work for Erection of galvanised steel for structures

5

7690

38450

... More
100% extra on erection charges for power block work for Erection of galvanised small parts steel (SPS).

1

8103

8103

... More
100% extra on erection charges for power block work for Erection of cantilever assembly (Conventional Type, including insulator)

10

850

8500

... More
100% extra on erection charges for power block work for Fabrication & erection of dropper assembly (Conventional OHE) including removal of old droppering.

120

74

8880

... More
100% extra on erection charges for power block work for Manual erection of overhead equipment (Conventional type).

0.2

-

7634.6

... More
100% extra on erection charges for power block work for Erection OHE termination assembly Conventional type including porcelain 9-tonne insulators.

2

1599

3198

... More
100% extra on erection charges for power block work for Erection of 3 pulley type ATD for Conventation OHE

2

3475

6950

... More
100% extra on erection charges for power block work for Erection of any type jumper assembly such as "G" jumper, AT jumper, Isolator jumper etc.

2

423

846

... More
100% extra on erection charges for power block work for Transfer of equipment from one mast or support to another including old bracket removal.

10

3293

32930

... More
100% extra on erection charges for power block work for Dismantling of OHE termination assembly

2

758

1516

... More
100% extra on erection charges for power block work for Dismantling of any type of ATD assembly

2

2377

4754

... More
Preparation of design & drawing for overhead equipment

-

8770

8770

... More
Supply of single earth electrode 3

-

-

2

... More
Erection of single earth electrode 4

3

770

2310

... More
Supply of various types of Galvanized traction bonds 50x6 mm. 5

100

175

17500

... More
Erection of various types of Galvanized traction bonds 50x6 mm. 6

100

50

5000

... More
Supply of various types of Galvanized traction bonds 40x6 mm. 7

200

175

35178

... More
Erection of various types of Galvanized traction bonds 40x6 mm.

200

46

9354

... More
Making of cable trench of suitable width & required depth with excavation & back filling of excavated earth. 9

1100

87

96096

... More
Supply of RCC warning cover as per specification. 10

2200

49

107800

... More
Laying of RCC warning cover as per specification. 11

2200

10

22000

... More
Supply of 50 mm dia. (OD) 'A' class GI pipe. 12

50

258

12943

... More
Laying of 50 mm dia. (OD) 'A' class GI pipe. 13

50

47

2373

... More
Supply of 150 mm size RCC hume pipe along with collar / coupler etc. 14

50

400

20000

... More
Laying of 150 mm size RCC hume pipe along with collar / coupler etc. 15

50

73

3650

... More
Supply of cast iron cable marker as per drawing. 16

50

211

10550

... More
Erection of cast iron cable marker as per drawing.

50

33

1650

... More
Laying of 2 X 70 sq. mm. Al. armoured cable in provided trench or through provided pipe on wall / structure. 18

1100

25

28468

... More
Laying of 2 X 70 sq. mm. Al. armoured cable by cleating on wall. 19

100

71

7119

... More
Supply of termination box for CLS cable. 20

1

3332

3332

... More
Erection of termination box for CLS cable.

1

499

499

... More
Supply of junction box with stand, aluminium busbar etc as per Drawing No. - BSL/TD/SK/232

2

2258

4517

... More
Erection of junction box with stand, aluminium busbar etc as per Drawing No. - BSL/TD/SK/232 23

2

279

559

... More
Breaking of foundation.

15

3545

53175



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.