Central Railway Tender

... More
Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.

Central Railway - CR Tender

Works
Electrical Goods and Equipments
Machinery and Tools
Ireps
Opening Date15 Apr 2025
Closing Date7 May 2025
Tender Amount₹ 2,96,73,534.56 
Notes
Download

Costs

Summary

Yard Re Modlling For Handling Up Long Haul Trains At Murtizapur Of Bhusawal Division Of Central Railway

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply of PVC Indoor Cable 1x60x0.6mm dia colour coding of insulation of inner core shall be in six colour Viz Blue , Red , Grey ,Green, Brown and Black conforming to IRS 76/89(Amdt 3) or latest. (Inspection by RDSO)

2

275870

551740.12

... More
Supply of PVC Indoor Cable 1x 40x0.6mm dia. Colour coding of insulation of inner core shall be in eight colour viz Blue,Red,Grey,Green,Brown,Black, Yellow & white.conforming to IRS 76/89 (Amdt 3) or latest. (Inspection by RDSO)

2

180977

361954.48

... More
Supply of PVC indoor cable 1 x 24 x 1 mm dia. Colour coding of insulation of inner Conductor shall be in eight colour viz Blue,Red,Grey,Green,Brown,Black, Yellow & white.conforming to IRS 76/89 (Amdt 3) or latest. (Inspection by RDSO)

-

-

6

... More
Supply of Indoor Jumper Wire ATC 1 x 1 mm dia. conforming to IRS 76/89 (Amdt 3) or latest. (Inspection by RDSO)

10

12013

120133.2

... More
Supply of Indoor Jumper Wire of various colour as per Railways standard practice of type ATC 1 x 0.6 mm dia.conforming to IRS 76/89 (Amdt 3) or latest. (Inspection by RDSO)

60

7934

476056.2

... More
Supply of low maintenance Lead Acid Secondary Cells 2V 80 AH. As per specn. IRS 88/2004 with latest amendment. (Inspection by RDSO)

75

1832

137429.25

... More
Supply of Rubber Mat 5 mm thick for use in signalling installation. (Inspection by CONSIGNEE)

50

118

5942

... More
Relay base plate complete with amophanols,code pins fixing screw etc.suitable for 11 Metal to Metal K-50 mini groups/ECRs of Siemens Make of functional equivalent of other makes. Note: Relay Base plates,are to be procured fom Relay manufacturer (OEM) Manufactures Certificate for procurement and guarantee in this regard should be furnished.The payment to be released only after Manufacturers Certificate is submitted. (Inspection by RITES)

250

669

167410

... More
Major Relay Group Base Plates, complete with fedlisters (20 No per base plate), guide 12 rails and other accessories suitable for major group of Siemens make or functional equivalent of other makes. Note: Relay Base plates,are to be procured fom Relay manufacturer (OEM) Manufactures Certificate for procurement and guarantee in this regard should be furnished.The payment to be released only after Manufacturers Certificate is submitted. (Inspection by RITES)

8

12330

98646.48

... More
Supply of Signal Group . 2 Aspect without base plate .siemens make(No.A-RT-RG-A066) ) or functional equivalent and should be suitable for working with LED based signal lighting unit. (Inspection by RDSO)

4

47511

190047.96

... More
Supply of Signal Group . 3 Aspect without base plate .siemens make(No.A-RT-RG-A067) ) or functional equivalent and should be suitable for working with LED based signal lighting unit. (Inspection by RDSO)

6

53021

318131.28

... More
Supply of Shunt Signal Group .Siemens make(No.A-RT-RG-A065) or functional equivalent without base plates. .(Suitable for LED Signal) (Inspection by RDSO)

6

52738

316428.78

... More
Supply of Route Group Siemens Make ( No RSSK 31/0002) or functional equivalent without base plates. (Inspection by RDSO)

8

54155

433244.56

... More
Supply of Point Group PI, Siemens make (No RSSK 31/0001) or functional equivalent without base plates. (Inspection by RDSO)

5

80021

400108.45

... More
Supply of Time Element Relay (Clock work type) AG timer Siemens Make (No RSSK 30/0052). or GIC make or functional equivalent. (Inspection by RDSO)

12

7150

85807.8

... More
Supply of Key Lock Relay with different ward combinations (three extra set of ward plate for Point Machine to be supplied with each relay). Siemens Make working on 60V DC/24 DC or functional equivalent without base plates. RDSO/SPN/219/2016 Version 1.0 d 1. (Inspection by RDSO)

5

8391

41956.95

... More
Supply of Plug In type Relay Metal to Metal type neutral relay mini groups (Non AC 20 Immunised) Siemens make (No. RSSK 30/0011) (Ref. IRS:S46/74 with Amd. 1 & firms specification.).or functional equivalent without base plates.Contact configuration 5F/3B or 6F/2B or 4F/4B to be specified by Engineer incharge. (Inspection by RDSO)

100

6553

655372

... More
Supply of Plug In type Relay Metal to Metal type neutral relay mini groups (AC 21 Immunised-1) Siemens make (No. RSSK 30/0078-1) (Ref. IRS:S46/74 with Amd. 1 & firms specification. ).or functional equivalent without base plates.Contact configuration 5F/3B or 6F/2B or 4F/4B to be specified by Engineer incharge. (Inspection by RDSO)

20

8323

166472

... More
Supply of Plug In type Relay Interlocked Siemens make (No. RSSK 30/0012) or functional equivalent (Ref. IRS:S46/74 with Amd. 1 & firms specification.). Contact configuration 4F/4B. (Inspection by RDSO)

60

6925

415547.4

... More
Supply of Metal -To-Metal universal LED type ECR Siemens make (type A-RT-RG-A064) or functional equivalent without base plate, should be suitable for working with LED based signal lighting unit. IRS:S:46 & STS/E/RELAYS/AC LIT LED SIGNAL/09-2002 Amd. 1 (Inspection by RDSO)

20

6351

127039

... More
Supply of QNA1 AC immunized relay 8F-8B,24VDC along with plug board, retaining clip and connectors conforming to BRS:931A,IRS:S60,IRS:S34 & IRS:S23 . (Inspection by RDSO)

40

3534

141381.2

... More
Supply of QSPA1relay, 24VDC,Slow to pick up, 8F.4B along with plug board, retaining clip and connectors conforming to BRS:933A,IRS:S60,IRS:S34 & IRS:S23. (Inspection by RDSO)

20

4050

81014

... More
Supply of QTA2 AC immunised track relay, 9 Ohm,2F.1B, along with plug board,retaining clip and connectors conforming to BRS:939A, 966, & appendix F2, IRS:S34& IRS:S23 (Inspection by RDSO)

20

3541

70827.6

... More
Supply of QBAT track Relay, AC immunised, 2F-2B contacts, 9 ohms. complete with plug board, retaining clip & connectors as per RDSO / SPN/84 ver 2.0 or latest. (Inspection by RDSO)

8

6058

48471.84

... More
Supply of Fail Safe Electronic Flasher Device 24V DC or 60V DC as per RDSO spec No.RDSO spec No.RDSO/SPN/173/2002 amendment 2 or latest. (Inspection by RDSO)

1

16483

16483.06

... More
Supply of Domino units with cover plate as per approved panel diagram, each of size 54 x 34mm completely wired up similar to Siemens make. Each domino units should have all the 15 contact terminals (Inspection by CONSIGNEE)

120

1485

178311.6

... More
Panel Indication bulbs (Double LED type) working Voltage 24V -Colour- Red/Yellow/Green. (Inspection by CONSIGNEE)

300

40

12297

... More
Supply of INDICATIVE TYPE OF FUSE INSERTS. IRS S:-78-92 With holder 1.6 A (System, Rapid or Mainad Make). (Inspection by CONSIGNEE)

300

73

21999

... More
Supply of INDICATIVE TYPE OF FUSE INSERTS. IRS S:-78-92 With holder 0.6 A (System, Rapid or Mainad Make). (Inspection by CONSIGNEE)

60

70

4249.2

... More
Supply of INDICATIVE TYPE OF FUSE INSERTS. IRS S:-78-92 Without holder 1.6 A (System, Rapid or Malnad Make). (Inspection by CONSIGNEE)

400

21

8448

... More
Supply of INDICATIVE TYPE OF FUSE INSERTS. IRS S:-78-92 Without holder 0.6 A (System, Rapid or Malnad Make (Inspection by CONSIGNEE)

200

21

4224

... More
Supply of INDICATIVE TYPE OF FUSE INSERTS. IRS S:-78-92 Without holder 6A/10A ( D- Type Bharat Linder , L&T or HEVELLS Make (Inspection by CONSIGNEE)

60

87

5268

... More
"Supply of Resisters, condensers, Diodes, LEDs and lugs alongwith bracket and mounting arrangement as per standard Annexure-V of Central Railway. (Inspection by CONSIGNEE) "

1

50956

50956.56

... More
Resin core wire as per specification No. IS:1921-1975 with Alloying element percentage as 63% SN (Tin) and / 37% Pb (Lead) with percentage of various impurities not exceeding the values 37 Sb (Antimony) 0.2% maximum , Cu (Copper) 0.1% maximum, As (Arsenic) 0.05% maximum, Fe (Iron) 0.02% maximum & other impurities mainly Al, Zn & Cd shall be limited. The flux shall be free from corrosive action as per clause 5.2 & flux percentage may be used as per requirement. (Inspection by CONSIGNEE)

5

1149

5746.2

... More
Lacing thread rolls, black, wax coated (100 mtrs) (Inspection by CONSIGNEE)

-

-

38

... More
Fabrication and supply of Board made of White sunmica sheet over 12 mm thick 39 particle/laminated/wooden board covered with 5 mm thick perspex transparent sheet in aluminium/ steel frame and Painting of SWR/Track insulation plan etc (Per SQ Mtr- 1 No. (Inspection by CONSIGNEE)

2

6700

13401.96

... More
Supply of Microprocessor based universal earth resistance sensing unit 12 channel AC/DC. as per RDSO/SPN/256/2002 with latest amendments. (Inspection by RDSO)

2

133612

267224.72

... More
Supply of Main Signal Post 140 mm outer dia 3.6 Mtr Length as per spec No IRS S 6/81 with latest amendments. (Inspection by RITES)

4

6268

25074.24

... More
Supply of Main Signal Post 140 mm outer dia 4.6 Mtr Length as per spec No IRS S 6/81 with latest amendments. (Inspection by RITES)

6

6375

38251.5

... More
Supply of Main Signal Post 140 mm outer dia 5.6 Mtr Length as per spec No IRS S 6/81 with latest amendments. (Inspection by RITES)

2

8471

16943.28

... More
Supply of Shunt Signal Post with Base (GI Pipe of 80 mm Dia of min. 1 meter length.). (Inspection by RITES)

10

2488

24881.2

... More
Supply of Cast Iron Main signal surface base140 mm as per spec No IRS S-10 and Drg 45 No 2011/M with latest amendments, with CLS ladder assembly complete for CLS signal 5.5/4.5/3.5 mtrs long as per R. No SA-23156(Adv),SA 23153(Adv) & SA 23150 (Adv) Alt. 1 respectively with latest Amendment as the case may be for CLS unit & signal back staging as per extant C.Rly practice (Inspection by RITES)

12

8288

99465.72

... More
Supply of Signal No.plates. as per Drg No RST-11393/SK 842 (Inspection by CONSIGNEE)

12

478

5743.8

... More
Supply of OFF set bracket 5-1/2 " to suit 140 mm dia CLS post with two nos. of "U" Bolts with nuts and washer complete as per RDSO Drg No SA-23080 for Signals & Routes (Inspection by RITES)

4

917

3669.04

... More
Supply of A/AG/C/P/G/IB Board as per Drg RST-11444/1(A), RDSO Drg No SA 23460(AG), SA 23461( C) , RST-11445 , SA 23456(P), SA 23477(G) & SA 234476-77(IB) as applicable respectively with latest Amendment (Inspection by CONSIGNEE)

12

515

6184.8

... More
Supply of Stop Board/IB Board as per RST 11791(STOP Board)/ RDSO Drg No 7235/B as per extent C.Rly practice. (Inspection by CONSIGNEE)

4

3064

12258.2

... More
Supply of different warning Boards as per Goods warning board(SK-784) RDSO Drg No. SA 2380 (Adv),SA 2370/M-,Block section limit board RDSO Drg No SA 2373- Paint and retroreflective arrangement as per railway drawing. (Inspection by CONSIGNEE)

2

2983

5967.54

... More
Supply of Hand Cuff Locks/ Godrej navtal lock with three common key (Inspection by CONSIGNEE)

20

262

5251.8

... More
Supply and Fixing of RE Protective Screens of expanded metal 12 SWG of size 12 SWG of size 1200 x 1500 mm on signals as per extant practice & as per instruction of Rly engineer at site.DRG NO-SK-844 (Inspection by CONSIGNEE)

2

4796

9592

... More
Supply of Phenolic 10mm thick sheet, grade P3 in standard size of 1.22X1.22 Mtr as per spec. No IS 2036 of 1995. (Inspection by RITES)

50

4817

240866

... More
Supply of ARA Terminal blocks with links made of PBT Specn No.IRS/75/2006(Rev - 2) with latest amendments and RDSO Drg.No.SA-23741 Alt.4., SA-23745 Alt 5, SA-23746, SA-23748 Alt - 4 & SA-23756 Alt-3. (Inspection by RDSO)

8000

66

532960

... More
Supply of cartridge fuse block made of PBT as per RDSO Drg No SA-23748 Alt 4,SA- 23749 & Spec No IRS S 75/2006 with latest amendment. Fuse block shall be suitable for round head type voltage fuses. (Inspection by RDSO)

100

149

14950

... More
Supply of round head type non detoriating type low voltage cartridge fuse as per Specn No IRS/S/78/92 with latest amendments 2A/4A/6A capacity (Inspection by RDSO)

100

64

6434

... More
Supply of Tik-tak, piano type switches,5 A (As per IS specification). (Inspection by CONSIGNEE)

-

-

57

... More
Supply of three pole plug and socket 5 Amp(As per IS specification).(Inspection by CONSIGNEE)

40

211

8472.4

... More
Supply of Apparatus Case with godown locks with deatachable handle on both the doors. Single Case as per Drg No SK 783-1&2. with latest alteration. (Inspection by RITES)

34

14698

499745.6

... More
Supply of Apparatus Case with godown locks with deatachable handle on both the doors. HalfCase as per Drg No SK 783-1&2. with latest alteration.(Inspection by RITES)

6

11793

70760.94

... More
Supply of Lamp 110V/24W,2 Pin for Loc. (Inspection by CONSIGNEE)

-

-

61

... More
Supply of earth electrode assembly as per Drg.No.CR/S&T/SK/815 (Inspection by RITES)

50

989

49457

... More
Supply of B type choke to specn.No.IRS.S.65/83 (Amdt -3) with latest amendments. (Inspection by RDSO)

20

3363

67277.6

... More
Supply of adjustable Track Feed Resistance disc type 7.5/15/30 ohms as per RDSO Drg. No. SA 20161-66/M (Adv) with latest amendments (with Phenolic moulded base). (Inspection by RDSO)

20

1181

23637.4

... More
Supply of Track feed battery chargers, 110V AC input 2, 4 to 6 V DC Output to Specn.No.IRS.89/2013/Ver 1.0 with latest amendments. Charger shall be suitable for charging 80 AH battery. (Inspection by RDSO)

20

2229

44596

... More
Supply of Channel Pins single groove, galvanised, 7 mm suitable for 4mm dia bonding wire as per spec No IRS S 17-75 Revision 3 . (Inspection by CONSIGNEE)

3000

1

5520

... More
Supply of PVC jacketed wire rope for Track Lead connections. PVC jacketed wire rope 67 should be of Galvanised steel wire rope 6 mm dia (6x19 stranded wire with steel core of 6 mm dia) sheathed with PVC 2mm wall thickness, overall thickness being 10 mm. PVC sheath should be made of type 6 compound as per IS 5831 of 1984 Reaffirmed 2001 and steel wire rope as per IS:2266:2019. Reclaimed or recycled material should not be used. (Inspection by RITES)

3000

47

143940

... More
Supply of 8 SWG GI wire (4mm dia) suitable for track circuit rail bonding .As per IRS specification S:13- 62 (Inspection by CONSIGNEE)

160

79

12745.6

... More
Supply of Hydrometer, Exide make or similar for measuring specific gravity of Battery Graded acid with mounting stand in location Boxes.Consignee inspection under manufacturer certificate. (Inspection by CONSIGNEE)

5

260

1301.2

... More
Supply of Pre-wired Crank Handle cum key lock relay box(of metal) along with LEDs,with approved type push buttons,8-way terminal strips,string rod, etc as per Drawing No.RST.C.114 (Inspection by RITES)

4

9604

38416.04

... More
Supply of William stretcher nylon insulation set suitable for ground connection as per RDSO drg No T-10367, T-10368, T-10384 as applicable and to the spec IRS S 23 & 40/84 with latest amendements .(Inspection by RITES)

12

487

5855.88

... More
Supply of Tongue attachment nylon insulation set consisting of one insulating plate as per Drg no: RST-106961 & 3 nos of Ferrules with collars to suite rodding supplied as per RDSO spec & Drg.no: RST-10692 (Inspection by RITES)

8

310

2483.12

... More
Supply Gauge Tie plate nylon insulation as per RDSO drg No: T- 10372Alt2, T-10368, T- 10371Alt2, T-15083/88/Alt2 & T-11690/Alt2 and to the spec IRS S 23 & 40 with latest amendements 01 or latest amandments .(Inspection by RITES)

8

223

1791.76

... More
Supply of Ground connections, complete set suitable for IRS type/appd. point Machine 74 for ordinary turnout with tounge attachment insulation and other insulation as per RDSO Drg. S/3361@ 47>47?40@for IRS type point machine) or RDSO Drg No.SA-9151/52 (for Siemens point machine) with latest amendements . However the ground connection shall be procured only after confirmation from Railway engineer as per site condition /type of machine/turnout. (Inspection by RITES)

8

7497

59977.52

... More
Supply of GI pipe, inner dia. 100mm dia. B-class as per spec. No.IS 1239 PT. 1/2004 or latest with sockets and fittings. TATA/JINDAL/ZENITH BIRLA Make. (Inspection by RITES)

360

944

339984

... More
Supply of DWC HDPE Pipe with one snap fit coupler and 'O' ring fire resistant, anti rodent,in 6mtr length of size 120 mm outer dia as per RDSO /SPN /204/2011/Ver 1.1 with Amdt 1 or latest. (Inspection by RITES)

360

294

106167.6

... More
Supply of thermo shrink Jointing kit (Reinforced) TSF-2 type generally conforming to 77 R D S O Specification No.RDSO/SPN/TC/57/2015 Rev 1 with modified kit contents as per CSTE Specification No.CR/SPN/TC/57 (A)/2015 dtd 06.01.2015(Table -A) to be suitable for jointing both 10/20/50 pair PIJF and 4/6 Quad cables alongwith sub-kit(Table-B) for armour continuity. (Inspection by CONSIGNEE)

10

2745

27451.3

... More
Supply, installation, testing and commissioning of remote indication unit along with all accessories for above item. (Inspection by RITES)

4

1529

6117.92

... More
Supply of 2 aspect signal unit in FRP body without lenses and transformers as per 79 RDSO Specification RDSO/SPN/194/2006/Rev 2.0 or latest complete to suit LED signals lamps and suitable for 140 mm dia post saves pigment finish on the back side of the and inside . White pigment finish inside the 2 aspect unit to avoid any extra paint cost. (Inspection by RITES)

6

28386

170321.46

... More
Supply of 3 aspect signal unit in FRP body without lenses and transformers as per 80 RDSO Specification RDSO/SPN/194/2006/Rev 2.0 or latest complete to suit LED signals lamps and suitable for 140 mm dia post saves pigment finish on the back side of the and inside . White pigment finish inside the 4 aspect unit to avoid any extra paint cost. (Inspection by RITES)

6

29093

174558

... More
Supply of Shunt signal position light type FRP complete as per RDSO spn no 81 RDSO/SPN/194/2006/Rev 2.0 or latest with off set bracket 3-1/2" to be fitted on 140 mm post drawing No. SA 23840 (Adv) Alt-2 for dependent type complete with signal unit bracket, terminals etc without lenses,lamp, lamp holder, and to suit LED signal lamp. (Inspection by RITES)

10

12799

127993.7

... More
Supply of One way Junction route indicator in FRP body without lenses and transformers as per RDSO spn RDSO/SPN/194/2006/Rev.2 .0 or latest complete and to suit LED signal lamp. (Inspection by RITES)

2

32143

64286.1

... More
Supply of two way Junction route indicator in FRP body without lenses and transformers as per RDSO spn RDSO/SPN/194/2006/Rev.2 .0 or latest complete and to suit LED signal lamp. (Inspection by RITES)

2

40766

81532.72

... More
Supply of three way Junction route indicator in FRP body without lenses and transformers as per RDSO spn RDSO/SPN/194/2006/Rev.2 .0 or latest complete and to suit LED signal lamp. (Inspection by RITES)

1

41466

41466.06

... More
Supply of "Calling ON" signal unit in FRP body without lenses and transformers as per RDSO Specification RDSO/SPN/194/2006/Rev.2 .0 or latest complete and to suit LED signal lamp. (Inspection by RITES)

4

7954

31818

... More
Supply of Adhesive Tapes rolls,PVC(18 mm x25 Mtr) Steel Grip/SCOTCH/ANCHOR (Inspection by CONSIGNEE)

10

30

307.4

... More
Supply of PPTC Fuse GP 60-185 UL-94 certifcaton(1.6 Amps) for internal/external current .Make:LITTLEFUSE,FUZETEC,TYCO,BOURN,RAYCHEM etc (Inspection by CONSIGNEE)

200

9

1860

... More
Supply of PPTC Fuse GP 60-400 UL-94 certifcaion (12V/4A)TF,TR Circuit) Make:LITTLEFUSE,FUZETEC,TYCO,BOURN,RAYCHEM etc (Inspection by CONSIGNEE)

80

7

628

... More
Supply of PPTC Fuse GP 250-185UL-94 Certifcaion (24V/4A)TPR Circuit) .Make:LITTLEFUSE,FUZETEC,TYCO,BOURN,RAYCHEM etc (Inspection by CONSIGNEE)

60

7

471

... More
Supply of Modular Terminal block of 2.5 sqmm 2 IN 2 out type disconnect type terminal 91 along with as per RDSO Specn.No.RDSO/SPN/189/2004 Rev 3.0. The current capacity of 16 Amps & more,The terminal should have marking at centre to view description from front.Material to be procured from RDSO approved firm only. (Inspection by RITES)

1400

107

150444

... More
Supply of End clamp for modular terminal block (Inspection by CONSIGNEE)

-

-

92

... More
Supply of End plates for modular terminal block (Inspection by CONSIGNEE)

-

-

93

... More
Supply of DIN channel for the terminals 1 Mtr each (Inspection by CONSIGNEE)

-

-

94

... More
Supply of marker card as per customer spec(10x10) (Inspection by CONSIGNEE)

-

-

95

... More
Supply of Electronic timers for DAC reset arrangement 3 sec to 30 sec with 2 NO/2NC contact working voltage 24V/60V DC siemens/ABB/L&T or SELEC(642xA programmable electronic timer switch)make (Inspection by RITES)

25

2586

64667.25

... More
Maintenance Free Earth As per RDSO/SPN/197/2008 or latest consisting of :1) Copper 97 bond steel electrode 3 Mtr long 17 mm dia with copper bonding thickness of min.250 micron & UL listed & marked -01 No 2) Earth enhancement compound RDSO Approved in sealed bag of 10Kgs-03 No 3) Copper strip 150x25x6 mm -02 No 4) Copper strip 300x25x6 mm -01 No 5)35 Sqmm Copper Cable to connect earth electrod to MEEB-15 Mtr Approx. (Inspection by RDSO)

30

16318

489568.8

... More
"Supply of RCC pipe half round of size 150mm dia outer and 100 mm dia internal 1 mtr long matching to IS No.458/2003 amendment-1 with Rev.4. (Inspection by RITES) "

5000

189

945650

... More
Supply of INDICATIVE TYPE OF FUSE INSERTS. IRS S:-78-92 With holder 6 A/10A ( D- Type Bharat Linder , L&T or HEVELLS Make). (Inspection by CONSIGNEE)

10

248

2482.7

... More
Supply of Track Lead Juction Boxes as per C.Rly Drg. No.RST 11509 made from fiiber glass alongwith terminal. (Inspection by RITES)

60

961

57691.2

... More
Installation of relay rack assembly including IDF pillars if any complete with wall 1 support, scaffolding, ladders, runway for cables,Relay/Relay group base plates, fixing of Tag block etc.The work shall be done as per approved plan, extant practice on C. Railway & instruction of Rly. Engineer at site.

6

1408

8448.66

... More
Installation of Cable Termination Racks Assembly complete including wall supports, 2 scaffolding, Disconnecting links/ARA terminal, 96 way tag block with tagblock cover & other necessary accessories etc. The work shall be done as per approved plan, extant practice on C. Railways & the instruction of Rly engineer at site.

2

1198

2397.66

... More
Termination of cable cores on ARA terminal/ fuse blocks,in the apparatus Cases/ cable termination rack.This includes all associated works of pulling out the cable from underground. The work shall be done as per location plans and instructions of Rly engineer at site.

8000

6

52080

... More
"Fixing of Q series relay base plate/metal to metal relay mini group and major group base plate, laying, bunching, lacing, dressing & packeting of 60/40 core PVC indoor cable/flexible wire and termination of 60/40 core cable/flexible wire on tagblock/base plate & base plates & soldering. This includes fuse wiring, bus bar looping etc. required for keeping installation ready for circuit wiring work & panel throughing work. The work shall be done as per approved plan, extant practice on C.Rly. & the instruction of Rly. Engineer at site. " UNIT 1 TAG BLOCK =1 NO

-

-

4

... More
"Circuit wiring/jumpering as per circuit diagrams in the relay racks/IDF rack tagblocks. This includes preparation of Jumper sheets by wire man duly checked by firm's site supervisor & wire 5 to wire testing as per circuit diagram. Any wrong jumper done by wireman will not be paid & correction shall be done free of cost. Jumper wires will be issued by Railways. Good quality solder rosin core to be supplied by contractor for soldering of Jumper wires. Soldering of jumper wires to be done after completion of testing by Railways. "

8000

11

89360

... More
"Relay Contact break test of indoor relay wiring.Contractor shall depute Engineer, 7 Supervisor & wiremen technically qualified to carryout contact break testing as per approved circuit diagrams. Firm Engineer to sign circuit diagrams for break testing after carrying out the test in presence of Railway's site supervisor/Engineer. " UNIT 1 CKT SHEET = 1 NO.

100

301

30124

... More
Installation, wiring, testing and commissioning of Data logger complete along with 9 accessories with Contractors own wiring & fixing material as per following configuration. (It includes loading of NETWORKING software and networking of data logger. The requisite communication cable/channel for networking will be arranged by Railway. 1024 digital & 32 analog inputs

1

19836

19836.5

... More
Charging of 2V Lead Acid Batteries with contractors own battery grade sulphuric acid 10 and distilled water with minimum two charge - discharge cycles, installation of charged batteries in groups & their connection & wiring. The work shall be done as per extant practice of C.Rly & instruction of Engineer-in-charge.Detailed measurements of initial charging shall be recorded jointly by contractor & Rly's site-in-charge. UNIT PER 100 VAh = 1 NO.

120

69

8353.2

... More
Supply and installation of 20 pair CT box

-

-

11

... More
Installation,fixing and wiring of Boxes for Key Lock Relays with contractors wiring & fixing material.The work shall be done as per extent practice on C.Rly & the instruction of site engineer.

4

2862

11448.16

... More
"Lettering & Numbering of detail and description writing of particulars of terminations 13 & equipments on relay rack, relays, cable termination rack, battery & power equipments, IPS, operating panel, axle counter etc constituting entire system with contractor's own paint and writing material (""Asian/Dulux"" make enamel paints to be used). The work shall be done as per extant practice on C.Rly & instruction of Rly engineer at site. UNIT 1 PER RECK = 1 NO. "

8

338

2704.56

... More
Preparation of cable route plan, cable coreage plan, location particulars, Cable termination rack particulars, cable meggering report, earth resistance particulars, Traction bonding diagram, 1/2 wire count sheet and any other drawing in Autocad in A3/A4 size. The contractor shall intially supply 3 sets of circuits complete for approval of Railway. Railways will return one set to the 14 contractor duly approved with alterations/corrections if any. The contractor shall incorporate Railways alterations/corrections in the tracings without any deviation and submit all tracings complete in all respects to the Railways . This includes submission of final cable route plan as per laid cable duly measured at every 30m clearly indicating distance of laid cable from fixed point of reference & indicating all track crossings and tail cables. This also include designing of cable coreage plan based upon I.P in consultation with engineer-in-charge.

1

22065

22065.75

... More
Excavation and Casting of main signal foundation as per Drg No SK 801 with 15 contractor's own materials including cement and anchor bolts of standard size. The required scaffolding Ferma etc for Casting of foundation will have to be brought by the contractor at his own cost.

12

8394

100734.24

... More
Excavation and Casting of Shunt Signal foundation as per Drg.No.SK 802 with 16 Contractor 's own materials including Cement and Anchor Bolts of Standard Size. The required scaffolding, Ferma etc for Casting of foundation will have to be brought by the Contractor at his own cost.

10

2430

24306.6

... More
Erection of CLS Post with Surface base and signal unit on top or on OFF set Bracket, 17 fixing of front and back staging, ladder and guards, signal name plates/boards if any with contractors own brackets and fixing materials. This also includes erection of auxiliary signals like calling on, shunt signal if any. The work shall be done as per instructions of Rly engineer at site.

12

3202

38427.36

... More
Erection of shunt signal with Surface Base, Post, Signal unit and fixing of No.plates. The work shall be done as per instructions of Rly engineer at site.

10

441

4417.2

... More
Fixing of Jn.Route Indication 1-Way/2-Way/3-Way on the top of the signal post.

-

-

19

... More
Fixing of Stop Board, Block section limit Board, goods warning board with contractors own material. The work shall be done as per instruction of Rly. engineer at site.

4

507

2030.52

... More
"Termination of tail cable on Main signal units and wiring with contractor own material, etc. The work shall be done as per instruction of Rly engineer at site."

12

1005

12069.96

... More
"Termination of tail cable on Shunt signal units and wiring with contractor own material, fixing of lenses etc. The work shall be done as per instruction of Rly engineer at site."

10

326

3268.4

... More
Fabrication and fixing of phenolic laminated/Fibre glass sheet in location box by 23 providing all fixtures as per Railway Drawing including fixing of PVC coated/with PVC pipe covered string rods at the back side for cable support with contractor's own materials. The work shall be done as per drg and arrangement similar to SK 783-1/2. with latest alterations & as per instructions of Rly engineer at site. Single Case

34

2065

70242.64

... More
Fabrication and fixing of phenolic laminated/Fibre glass sheet in location box by 24 providing all fixtures as per Railway Drawing including fixing of PVC coated/with PVC pipe covered string rods at the back side for cable support with contractor's own materials. The work shall be done as per drg and arrangement similar to SK 783-1/2. with latest alterations & as per instructions of Rly engineer at site. HALF CASE

6

1821

10926.24

... More
Fixing of cutting in relay bases & wiring of relays with Contractors own material obtained from approved sources in location box as per the instuctions of Engineer in charge.

30

519

15585.9

... More
Fixing of ARA Terminalsand fuse blocks on phenolic laminated sheets and fixing by stainless steel/brass nuts & bolts.This includes provision of two additional holes on the board on either side for cable conductor entry.

8000

12

103120

... More
Termination of cable cores on ARA terminal/ fuse blocks,in the apparatus Cases/ cable 27 termination rack.This includes all associated works of pulling out the cable from underground. The work shall be done as per location plans and instructions of Rly engineer at site. UNIT 1 PER CONDUCTER = 1 NO

12000

9

116520

... More
Excavation and Casting of Apparatus Case foundation with contractors Anchor bolts, cement, ballast and other materials.The required Scaffolding Ferma etc for Casting of foundation will have to be brought by the contractor at his own cost Single Case as per Drg No SK 803

34

9071

308425.56

... More
Excavation and Casting of Apparatus Case foundation with contractors Anchor bolts, cement, ballast and other materials.The required Scaffolding Ferma etc for Casting of foundation will have to be brought by the contractor at his own cost HALF Case as per Drg No SK 804

6

8894

53365.08

... More
Erection of Apparatus Cases. This includes filling of location foundations and plastering Single Case

-

-

30

... More
Erection of Apparatus Cases. This includes filling of location foundations and plastering Half Case

6

772

4637.4

... More
Installation of Eqpt. (Relays, resistance, chargers batteries etc.as applicable) & wiring of the same in apparatus Cases as per location diagrams & circuit diagrams, as per Instruction of site incharge and practice. Single Case

34

1374

46721.44

... More
Installation of Eqpt. (Relays, resistance, chargers batteries etc.as applicable) & wiring of the same in apparatus Cases as per location diagrams & circuit diagrams, as per Instruction of site incharge and practice. HALF Case

6

933

5602.86

... More
Erection, Fitting and Rail connection of Track Lead Juntion Box on two 34 supports(M.S.angle) with contractor's fixing material and PVC jacketed wire for track lead connection including angles of size 40 x 40 x 5 mm 1200 mm length. This will include drilling of holes for track lead/side connections on rail. The work shall be done as per Drg. No.SK-845 or/ & instructions of Rly engineer at site.

60

1197

71859

... More
Provision of bonding with contractor's PVC jacketed wire rope for Track Lead connections.PVC jacketed wire rope should be of Galvanised steel wire rope 6mm dia (6 x 19 stranded 35 wire with steel core of 6 mm dia ) sheathed with PVC 2mm wall thickness, overall thickness being 10mm PVC sheath should be made of type 6 compound as per IS 5831 of 1984 Reaffirmed 2001 and steel wire rope as per IS:2266:2019.Reclaimed or recycled material should not be used .This will include drilling of 7.1mm dia holes in rails (4 Nos) and provision of two jumpers for each bond, clipping of bonds etc. with contractors own materials and tools as per instruction of Rly engineer at site.

300

155

46695

... More
Provision of bonding with GI wire 4mm dia ( 8 SWG) for track jumper & fish plate joints bonds. This will include drilling of 7.1mm dia holes in rails (4 Nos) and provision of two jumpers for each bond, clipping of bonds etc. with contractors own tools as per instruction of Rly engineer at site.

100

147

14724

... More
"Fixing of point machine on newly laid turnout on Wooden/MBC sleepers , fixing of ground connections, adjustment and testing with crank handle operations,Removal of ground 37 connection & point machines duly numbered. This will include fixing of bend pipes with welded frame for cable entry to machine. This will also includes necessary adjustment and smithy work, drilling of holes to tounge rails, fitting of insulation for tounge attachment, gauge plate & stretcher bars, cable termination & wiring if required. The work shall be done as per extant practice on C. Rly & the instruction of Rly engineer at site." UNIT 1 PER T/OUT = 1 NO.

4

3235

12943.32

... More
Excavation of cable trench as per cable route plan,1.0 mt. deep and 300mm wide along side the track in normal soil/strata, conforming to distances as per cable route plan and refilling after cable laying. This work includes covering of cable laid in trench by loose soil for a layer of 50mm 38 thickness after clearing of route,bushes etc.It shall be ensured that top of the cables laid is at a depth of 0.8 m or more If it is less,then the width and depth shall be suitably increased and accordingly proportionate payment shall be made .In case depth of trench is not achievable due to site conditions,Proportionate payment will be made as per procedure.The work shall be done as per the extant practice on Central Railway and instructions of Railway Engineer at site.Drg No.SK 805

1200

321

385356

... More
Excavation of cable trench as per cable route plan,1.0 mt. deep and 300mm wide along side the track in hard soil, conforming to distances as per cable route plan and refilling after cable laying. This work includes covering of cable laid in trench by loose soil for a layer of 50mm 39 thickness after clearing of route,bushes etc.It shall be ensured that top of the cables laid is at a depth of 0.8 m or more If it is less,then the width and depth shall be suitably increased and accordingly proportionate payment shall be made .In case depth of trench is not achievable due to site conditions,Proportionate payment will be made as per procedure.The work shall be done as per the extant practice on Central Railway and instructions of Railway Engineer at site.Drg No.SK 805

400

535

214084

... More
Cutting of all types of Roads/ platforms (except concrete type ) for trenching and 40 excavation to depth of 300mmx300mm wide approx. and refilling after laying of RCC/GI/DWC pipe & to restore them to original condition. The work shall be done as per extant practice on C.Rly & instructions of Rly engineer at site.SK-807

20

2676

53520.8

... More
Fixing of GI pipes for crossing the culverts, bridges etc. and concreting of ends with brick masonry at both ends as per the instruction of Rly engineer at site.

360

64

23112

... More
Digging of trench 1.0M deep from rail flange/road level (for LC) and 0.3 mtrs to 0.6 42 Mtrs wide and back filling after placing of DWC/RCC/GI pipe (Placing of DWC/RCC/GI pipe coverd separately) The ballast disturbed be screened and dressed as required by Engineerin-charge or his representatives and road tarred immediately.Drg No.SK 806

100

535

53521

... More
Laying of DWC/RCC pipes alongwith collars/RCCHalf round pipe in trenches at places of track and road crossings, platform cuttings etc.

360

52

18777.6

... More
Laying of signalling/Power/Telecom cable of various cores/sizes in trenches.

-

-

44

... More
Placing and securing of cable route markers in trenches at the specified interval and at diversions, joints etc along the cable route. The work shall be done as per extant practice on C Railways & the instruction of Rly engineer at site.

100

11

1150

... More
Jointing of 4 / 6 quad cable with Heat Shrinkable straight through Jointing Kit for 4 / 6 quad cable.

10

3268

32683.1

... More
Whereever depth of 0.5 m cable trench is not feasible cable shall be protected as under :- Preparation of cement mixture 1:3:6 with contractor's own materials and spreading cement concrete mixture layer of 100 mm thick over the already laid cables in the excavated trench.

50

4889

244493

... More
Painting two coats of synthetic enamel paint over one coat of Red Oxide primer after scrapping and cleaning of the surface wherever necessary with contractor own supply of primer and 48 paints over all outdoor gears including lifting barrier, axlecounter, ground frame, point machine, location boxes, signal post, unit, track circuits etc The work shall be done as per extant practice on C Rly & the instructions of Rly engineer at site. (Paints to be used shall conform to relevant IS spec.). This includes Lettering / Numbering Termination particulars, equipment names etc. legibly and neatly inside and outside surface of units, boxes etc.- for Big stations

1

53342

53342

... More
Releasing of Existing Panel, Power Equipments,relays and relay racks, CT racks, 49 Batteries, Block Instts., Ground frame/s, Location Boxes, TLJBs, Signal Posts, Signal Units, Equipment inside the location boxes, Lifting Barrier , rodding runs,etc as applicable including the breaking of foundation etc. as per the instructions of Rly Engineer at site & their transportation to nominated depot.

1

37567

37567.38

... More
Installation of earth electrode assenbly as per Drg.No.RE/S&T/SIG/Tender/SK726/85 including earth wire connected through GI wire 8 SWG supported on M.S. flat of size 6mm x 40 mm to earth electrode as per drg. No.CR/S&T/SK-815 for sigg. Equipment such as lever frames, apparatus 50 case, signals, relay racks,block insruments, and etc. as per RE manual. The earth value should be less than 10 Ohms including the lead wire. The value should be measured in presence of Rly. supervisor. It should be documented and painted on earth enclosure made of concrete.( only earth electrode will be supplied by Railway). All other material required for provision of earthing will be brought by the contractor.

50

2319

115978.5

... More
"Patching work in old location box consisting 1) Digging of pit , cleaning of earth from 51 all sides ,breaking of seal of location boxes removal of sand from location , marking of new cable holes 2) insertion cable from ground 3)making place for cable termination in old location ,shifting ARA , fuse etc after removal and termination including fixing of ARA. 4)Termination of cable in old location. 5) Filling of sand and plastering to all sides upto 50 mm below ground level."

10

5761

57618.2

... More
Horizontal boring of cable duct of minimum 2.0 mtr depth along with laying of 120 mm HDPE pipe for track crossing wirh minimum depth reckoned from bottom of the rail/Road crossing with 52 minimum depth reckoned from ground level. The work shall be done as per extent practice & instruction of site engineer.Preparation of site for Horizontal boring shall be carried out in presence of Railway Representative.HDPE will be supplied by Railway. Note:- Contractor shall provide all material required for boring and adequate nos.of labours for proper laying of cable into the bore.Cable shall be laid cautiously so that it should not get damage due to rough handling & pressure on cable.

300

2395

718530

... More
"Installation of complete assembly of track device/double rail contact unit for entry or exit with conductors all material including drilling of required sizes holes on rails for fixing these, taking the cable lead through anti-rodent, anti-oxidant & non-flame propagating type Double walled corrugated (DWC) pipe as per RDSO/SPN/204/2011 Ver 1.1 with Amd.1 or latest from track device to location box and terminating it on terminals including digging of trench under track and up to location/Track side unit and all other accessories as per site requirement for laying of transmitter and receiver cable with suitable wire embeded rubber pipe with clamp for protecting these cables at DP end." UNIT 1 Per track device/double rail contact =1 NO

-

-

53

... More
"Installation, wiring & Testing/commissioning of Axle counters Reset Box of all types in 54 Cabin/Panel Room and wiring the same to integrate with the axle counter as per the instruction of Railway engineer at site. This includes laying & termination of cable, if any from Panel Room/Axle couter room/Relay room to Reset Box in DWC pipe/existing ladder. "

1

7023

7023.8

... More
Supply, fixing & Wiring of mismatch panel dipcting Indication Panel/VDU layout with 55 contractors own material like LEDs for each track section, flexible wire, connecting terminals, buzzer etc. The work shall be done as per extant practice on C. Rly & the instruction of Rly engineer at site. UNIT 1 PER STATION = 1 NO.

1

45986

45986.3

... More
"Installation of unit earth as per RDSO/SPN/197/ver I or latest, to construct earthing of

30

4853

145616.7

... More
Laying of RCC half round cement pipe of approximate size (150/300 mm dia X 2 Meter length) inside the trench after laying of cable. Pipes shall be placed as per directives of engineer

5000

33

167200

... More
"Shifting of existing Full Location Boxes coming in the alignment of doubling. The work includes losing & removal of soil around location boxes by excavating soil around foundation, making of pit for shifting of location box horizontally opposite to railway track up to 0.5 to 1.0 mtr. This 58 includes loosing of existing cable coils without any damage. The excavated soil shall be back filled after shifting of Locaion Boxes. Location box along with its foundation shall be shifted by push method with the help of jacks or by crane by contractors own expenditure under instructions of engineer in- charge at site. Any minor repairs in foundation due to patching shall also be carried out by contractor as per instruction of Engineer incharge.The work may affect train working hence the work shall be done as per margin only or during traffic block only."

10

4998

49982.4

... More
"Shifting of existing Half Location Boxes coming in the alignment of doubling. The work includes losing & removal of soil around location boxes by excavating soil around foundation, making of pit for shifting of location box horizontally opposite to railway track up to 0.5 to 1.0 mtr. This 59 includes loosing of existing cable coils without any damage. The excavated soil shall be back filled after shifting of Locaion Boxes. Location box along with its foundation shall be shifted by push method with the help of jacks or by crane by contractors own expenditure under instructions of engineer in- charge at site. Any minor repairs in foundation due to patching shall also be carried out by contractor as per instruction of Engineer incharge. The work may affect train working hence the work shall be done as per margin only or during traffic block only."

5

4025

20127.8

... More
"Transferring of signalling/Telecom cables from existing Location box to New location box. The work include breaking/dismantling of existing foundation of locations, excavating and removing /segregating coils of this cables which may be of about 10 mtr in length .These cables are then to be disconnected and removed from the existing locations one by one as per the instructions and under the supervision of railway staff present at site. The cable is then to be inserted and 60 terminated in new location box. The item includes neatly dressing of cables marking wiring tree etc. The material required for dressing /lacing will be arranged by contractor at its won cost. The work is required to be done systematically and with due precaution during the night block of 2.00-2.30 hrs each or within the time that may be allowed. The excavation work to be done carefully without damaging the cables to avoid undue failures. (Termination charges will be given separately) Note: Proportionate payment will be made if cable is of other length. 2/6/12/19/24/30 core signalling cable/4 or 6 Quad/PIJF/Any Signalling/Telecom Cable(One no. unit= One cable of 10 m length)"

15

433

6497.25

... More
"Location strenthening of full case with wiremesh and concrete mixture as per drawing of full location "

10

6901

69015.1

... More
"Location strenthening of Half case with wiremesh and concrete mixture as per drawing of Half location "

-

-

62

... More
Supply of Revolving chair Godrej Make Model No. PCH 7001 or similar (Inspection by CONSIGNEE)

2

14680

29360

... More
Loading, un-loading & transportation of material from the Stores of SSE(SIG) depot or any other nominated place & vice-versa. ( Unit Per Ton Per Km.= 1 lot)

10000

4

46600

... More
Design for alterations to existing signalling circuits and supply of modified signaling circuits includuing panel digram,route seection plan, selection table, fuse and negetive tag block 3 analysis, contact analysis, relay rack arrengment and 1/2 wire count sheet etc for RRI the contractor shall initially supply three sets of circuits complete for approval of railway ,railway will return one set to contractor duly approved with alterations / corrections if any, the contractor shall incorporate railways alteration /correction in tracing without any deviation and submit all tracing complete in all respect to railways . he shall ensure that each

1

85000

85000

... More
"Electric Point Machine Non-Trailable type confirming to RDSO Specification No. IRS: S- 24/2002 amendment No. 1 or latest with following further information. A) 220MM throw with 4 Interlocking for operation of point in Railway yard as per RDSO Drg. No.S- 11000. B) Type of Ground connection with Nylon insulation confirming RDSO Drg. No. S- 3454 & clamp point lock confirming to RDSO Drg. No. 3395 for 60 Kg Thick web switch. C) AC immunitylevel of Motor for Electric Point Machine should be of 400V (r.m.s) 50HZ. The external colour of Electric motor shall be painted with Red colour."(Inspection by RDSO)

5

112690

563450

... More
Supply of cable route marker as per RST/C/203 of FRP.(Inspection by Consignee)

-

-

5

... More
"Supply of Electric Point Machine IRS type, 110V DC, Non-trail able, 143 mm stroke as 6 per DRG. no. RDSO/S-10800 complete as per specification no. IRS: S-24/2002 with latest amendment with complete accessories viz. slides for lock & detector, cable termination box, telescopic pipes, tool kit with every 8 point machine" (Inspection by RDSO)

4

93000

372000



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.