Central Railway Tender

... More
Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.

Central Railway - CR Tender

Works
Civil And Construction
Civil Works Others
Electrical Cables And Wires
Electrical and Electronics
Ireps
Opening Date16 Apr 2025
Closing Date8 May 2025
Tender Amount₹ 5,80,20,649.2 
Notes
Download

Costs

Summary

S&t Work In Connection With Safety Fencing Along The Track And Provision Of

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
"Supply of cartridge fuse block made of PBT as per RDSO Drg No SA-23748 Alt 4,SA- 23749 & Spec No IRS S 75/2006 with latest Amendment. Fuse block shall be suitable for round head type voltage fuses." (Inspection By RDSO)

150

162

22424.62

... More
Supply of round head type non detoriating type low voltage cartridge fuse as per Specn No IRS/S/78/92 with latest amendments2A/4A/6A capacity (Inspection By RDSO)

150

70

9651.64

... More
Supply of Tik-tak, piano type switches,5 A (As per IS specification). (Inspection By Consignee) 163A 80.00 Numbers 22.73 1818.40 (-) 8.25 1668.38

80

33

2452.29

... More
Supply of Lamp 110V/24W,2 Pin for Loc. (Inspection By Consignee) 164Aa 40.00 Numbers 16020.05 640802.00 (-) 8.25 587935.83

40

-

7

... More
Supply of Apparatus Case with godown locks with deatachable handle on both the doors. A) Single Case as per Drg No SK 783-1&2. with latest alteration. (Inspection by RITES)

-

-

8

... More
Supply of Apparatus Case with godown locks with deatachable handle on both the doors. B) Half Case as per Drg No SK 783-1&2. with latest alteration. (Inspection by RITES)

40

12853

471739.6

... More
Supply of earth electrode assembly as per Drg.No.CR/S&T/SK/815 (Inspection By Consignee)

80

1078

79131.07

... More
SUPPLY OF Maintenance Free Earth As per RDSO/SPN/197/2008 or latest consisting of :1) Copper bond steel electrod 3 Mtr long 17 mm dia with copper bonding thickness of min.250 micron 11 & UL listed & marked -01 No 2) Earth enhancement compound RDSO Approved in sealed bag of 10Kgs-03 No 3) Copper strip 150x25x6 mm -02 No 4) Copper strip 300x25x6 mm -01 mm 5)35 Sqmm Copper Cable to connect earth electrod to MEEB-15 Mtr Approx. If required , additional earth enhancement compound shall be provided free of cost to ensure earth value below 01 ohm. (Inspection By RDSO)

40

17786

652758.31

... More
Supply of 8 SWG GI wire (4mm dia) suitable for track circuit rail bonding .As per IRS specification S:13-62 (Inspection by Consignee)

400

86

31862.94

... More
Supply of Hydrometer, Exide make or similar for measuring specific gravity of Battery Graded acid with mounting stand in location Boxes.Consignee inspection under manufacturer certificate.(Inspection by Consignee)

200

283

52047.94

... More
Supply of GI pipe, inner dia. 100mm dia. B-class as per spec. No.IS 1239 PT.1/2004 or latest with sockets and fittings. TATA/JINDAL/ZENITH BIRLA Make.(Inspection By RITES)

42

1029

39664.85

... More
Supply of DWC HDPE Pipe with one snap fit coupler and 'O' ring fire resistant, anti rodent,in 6mtr length of size 120 mm outer dia as per RDSO /SPN /204/2011/Ver 1.1 with Amdt 1 or latest. (Inspection By RITES)

42

321

12386.31

... More
"Supply of RCC pipe half round of size 150mm dia outer and 100 mm dia internal 1 mtr long matching to IS No.458/2003 amendment-1 with Rev.4." (Inspection By RITES)

600

206

113480.07

... More
Supply of Modular Terminal block of 2.5 sq mm 2 IN 2 out type disconnect type 17 terminal along with as per RDSO Specn. No. RDSO/SPN/189/2004 Rev 3.0. The current capacity of 16 Amps & more, The terminal should have marking at centre to view description from front. The terminals should have latest push -X technology for easy wiring. Material to be procured from RDSO approved firm only preferably of phoenix make.(Inspection By RITES) 220A 6.00 Numbers 216.73 1300.38 (-) 8.25 1193.10

6

117

64474.56

... More
Supply of DIN channel for the above terminals 1 Mtr each (Inspection By Consignee) 221A 50.00 Numbers 23.39 1169.50 (-) 8.25 1073.02

50

-

18

... More
Supply of End plates for modular terminal block (Inspection By Consignee) 222A 50.00 Numbers 16.81 840.50 (-) 8.25 771.16

50

-

19

... More
Supply of End clamp for modular terminal block (Inspection By Consignee)

-

-

20

... More
"Tool bag complete with Megger as per Annexure -VIII. ADD AC /DC clamp meter, with Hand Held Tool Bag. (Inspection by Consignee)"

6

52213

287435.15

... More
Supply of thermo shrink Jointing kit (Reinforced) TSF-2 type generally conforming to 22 RDSO Specification No. RDSO/SPN/TC/57/2015 Rev 1 with modified kit contents as per CSTE Specification No.CR/SPN/TC/57 (A)/2015 dtd 06.01.2015(Table -A) to be suitable for jointing both 10/20/50 pair PIJF and 4/6 Quad cables along with sub-kit(Table-B) for armour continuity. (Inspection by RITES)

200

2991

549026.49

... More
Supply of Indoor Jumper Wire of various colour as per Railways standard practice of type ATC 1 x 0.6 mm dia.conforming to IRS 76/89 (Amdt 3) or latest. (Inspection By RITES)

2

8647

19370.87

... More
Supply of PVC Flexible Copper Cable, Single core, multi strand 1x2.5 sq mm(50 2 conductor each dia 0.25 + /- 0.01) as per specn IRS 694/2010 with latest amendment. If any with insulation thickness of 0.70 mm nominal conductor resistance 7.98 ohms /km and test parameters are as per (S)76/89 (Amdt .3). (Inspection By RITES)

2

44575

99849.46

... More
Supply of wire 16/0.2(blue,red,gray,yellow,brown,black,white as per site engineer instruction)finolex/polycab/delton make.IRS:S-76/89(Amd.3),BS:4808 Part-2.Wire to be procured from RDSO approved vendor (Inspection By RITES)

6

6445

43311.54

... More
Supply of Phenolic 10mm thick sheet, grade P3 in standard size of 1.22X1.22 Mtr as per spec. No IS 2036 of 1995. (Inspection By RITES)

18

5250

105849.68

... More
Supply of ARA Terminal blocks with links made of PBT Specn No.IRS/75/2006(Rev - 2) with latest amendments and RDSO Drg.No.SA-23741 Alt.4., SA-23745 Alt 5, SA-23746, SA-23748 Alt - 4 & SA-23756 Alt-3. (Inspection By RDSO)

5400

72

439145.28

... More
Supply of Apparatus Case with godown locks with deatachable handle on both the doors. A) Single Case as per Drg No SK 783-1/2. with latest alteration. (Inspection By RITES)

18

16020

322964.21

... More
Supply of earth electrode assembly as per Drg.No.CR/S&T/SK/815 (Inspection By Consignee)

18

1078

21734.09

... More
SUPPLY OF Maintenance Free Earth As per RDSO/SPN/197/2008 or latest consisting of :1)Copper bond steel electrod 3 Mtr long 17 mm dia with copper bonding thickness of min.250 micron 8 & UL listed & marked -01 No 2) Earth enhancement compound RDSO Approved in sealed bag of 10Kgs-03 No 3) Copper strip 150x25x6 mm -02 No 4) Copper strip 300x25x6 mm -01 mm 5)35 Sqmm Copper Cable to connect earth electrod to MEEB-15 Mtr Approx. If required , additional earth enhancement compound shall be provided free of cost to ensure earth value below 01 ohm. (Inspection By RDSO)

18

17786

358572.41

... More
Supply of GI pipe, inner dia. 100mm dia. B-class as per spec. No.IS 1239 PT.1/2004 or latest with sockets and fittings. TATA/JINDAL/ZENITH BIRLA Make. (Inspection By RITES)

162

1029

186759.82

... More
Supply of DWC HDPE Pipe with one snap fit coupler and 'O' ring fire resistant, anti rodent,in 6mtr length of size 120 mm outer dia as per RDSO /SPN /204/2011/Ver 1.1 with Amdt 1 or latest. (Inspection By RITES)

102

321

36720.16

... More
Supply of RCC pipe half round of size 300mm dia outer and 250 mm dia internal 1 mtr long. matching to IS No.458/2003 amendment-1 with Rev.4. (Inspection by RITES)

1500

422

709380

... More
"Supply of Permanently Lubricated HDPE Telecom duct of size 50/42 mm and 1 accessories as per latest Specification TEC GR No. GR/TX/CDS-008/03/March 11 with latest amendment" for OFC cable of size 24 fibre armoured in length of 1000 mtrs/roll. Duct to be supplied from TEC approved sources." (Inspection by RITES)

62900

73

4594845

... More
Supply of DWC HDPE Pipe with one snap fit coupler and 'O' ring fire resistant, anti rodent,in 6mtr length of size 120 mm outer dia as per RDSO /SPN /204/2011/Ver 1.1 with Amdt 1 or latest. (Inspection by RITES)

1032

321

331715.76

... More
Supply of thermo shrink Jointing kit (Reinforced) for quad cable conforming to RDSO Specification No. IRS: TC 77-2012 with ammendment 3 or later. (Inspection by RITES)

126

2991

376988.22

... More
Fabrication and fixing of phenolic laminated/Fibre glass sheet in location box by 1 providing all fixtures as per Railway Drawing including fixing of PVC coated/with PVC pipe covered string rods at the back side for cable support with contractor's own materials. The work shall be done as per drg and arrangement similar to SK 783-1/2. with latest alterations & as per instructions of Rly engineer at site. A) Single Case

40

2251

82638.49

... More
Fabrication and fixing of phenolic laminated/Fibre glass sheet in location box by 2 providing all fixtures as per Railway Drawing including fixing of PVC coated/with PVC pipe covered string rods at the back side for cable support with contractor's own materials. The work shall be done as per drg and arrangement similar to SK 783-1/2. with latest alterations & as per instructions of Rly engineer at site. B) Half Case Per44B 8000.00 14.05 112400.00 (-) 8.25 103127.00

40

1984

72841.43

... More
Excavation and Casting of Apparatus Case foundation with contractors Anchor bolts, cement, ballast and other materials.The required Scaffolding Ferma etc for Casting of foundation will have to be brought by the contractor at his own cost. A)Single Case as per Drg No SK 803

40

9887

362853.63

... More
Excavation and Casting of Apparatus Case foundation with contractors Anchor bolts, cement, ballast and other materials.The required Scaffolding Ferma etc for Casting of foundation will have to be brought by the contractor at his own cost. B) Half Case as per Drg No SK 804

40

9693

355767.23

... More
Erection of Apparatus Cases. This includes filling of location foundations and plastering . A) Single Case

40

1098

40298.07

... More
Erection of Apparatus Cases. This includes filling of location foundations and plastering . B) Half Case

40

842

30916.08

... More
Installation of Eqpt. (Relays, resistance, chargers batteries etc.as applicable) & wiring of the same in apparatus Cases as per location diagrams & circuit diagrams, as per Instruction of site incharge and practice. A) Single Case

40

1497

54966.32

... More
Installation of Eqpt. (Relays, resistance, chargers batteries etc.as applicable) & wiring of the same in apparatus Cases as per location diagrams & circuit diagrams, as per Instruction of site incharge and practice. B) Half Case

40

1017

37352.53

... More
Installation of earth electrode assenbly as per Drg.No.RE/S&T/SIG/Tender/SK726/85 including earth wire connected through GI wire 8 SWG supported on M.S. flat of size 6mm x 40 mm to earth electrode as per drg. No.CR/S&T/SK-815 for sigg. Equipment such as lever frames, apparatus 10 case, signals, relay racks,block insruments, and etc. as per RE manual. The earth value should be less than 10 Ohms including the lead wire. The value should be measured in presence of Rly. supervisor. It should be documented and painted on earth enclosure made of concrete.( only earth electrode will be supplied by Railway). All other material required for provision of earthing will be brought by the contractor.

80

2528

185565.48

... More
Installation of unit earth as per RDSO/SPN/197/ver I or latest, to construct earthing of

40

5290

194155.48

... More
Excavation of cable trench as per cable route plan,1.0 mt. deep and 300mm wide along side the track in normal soil/strata, conforming to distances as per cable route plan and refilling after cable laying. This work includes covering of cable laid in trench by loose soil for a layer of 50mm 12 thickness after clearing of route,bushes etc.It shall be ensured that top of the cables laid is at a depth of 0.8 m or more If it is less,then the width and depth shall be suitably increased and accordingly proportuonate payment shall be made .In case depth of trench is not achievable due to site conditions,Proportionate payment will be made as per procedure.The work shall be done as per the extant practice on Central Railway and instructions of Railway Engineer at site.Drg No.SK 805

300

350

96337.5

... More
Excavation of cable trench as per cable route plan,1.0 mt. deep and 300mm wide along side the track in hard soil, conforming to distances as per cable route plan and refilling after 13 cable laying. This work includes covering of cable laid in trench by loose soil for a layer of 50mm thickness after clearing of route,bushes etc.It shall be ensured that top of the cables laid is at a depth of 0.8 m or more If it is less,then the width and depth shall be suitably increased and accordingly proportuonate payment shall be made .In case depth of trench is not achievable due to site conditions,Proportionate payment will be made as per procedure.The work shall be done as per the extant practice on Central Railway and instructions of Railway Engineer at site.Drg No.SK 805

60

583

32112.32

... More
Cutting of all types of Roads/ platforms (except concrete type ) for trenching and 14 excavation to depth of 300mmx300mm wide approx. and refilling after laying of RCC/GI/DWC pipe & to restore them to original condition. The work shall be done as per extant practice on C.Rly & instructions of Rly engineer at site.SK-807

8

2916

21408.36

... More
Digging of trench 1.0M deep from rail flange/road level (for LC) and 0.3 mtrs to 0.6 15 Mtrs wide and back filling after placing of DWC/RCC/GI pipe (Placing of DWC/RCC/GI pipe covered separately) The ballast disturted be screened and dressed as required by Engineer in-charge or his representatives and road tarred immediately. Drg No.SK 806 87B 492.00 Kilometre 5197.42 2557130.64 (-) 8.25 2346167.36

12

583

6422.46

... More
Laying of signalling/Power/Telecom cable of various cores/sizes in trenches.

-

-

16

... More
Whereever depth of 0.5 m cable trench is not feasible cable shall be protected as under :- Preparation of cement mixture 1:3:6 with contractor's own materials and spreading cement concrete mixture layer of 100 mm thick over the already laid cables in the excavated trench.

100

5329

488986.21

... More
"Fixing of modular terminal/fuse blocks alongwith all accessories with provision of 18 fixing holes on hylam sheets/side angles of Loc Box and fixing by galvanised nuts & bolts. This includes fixing of DIN channel alongwith PVC Comb type 'C' channel (size 2 inch x 2 inch) for cable termination on modular terminal. The PVC channel with cover to be supplied by firm as required. The work shall be done as per the instruction"

600

19

10487.02

... More
"Termination of cable cores on ARA terminal/Disconnecting link/fuse blocks, in the 19 apparatus Cases/ cable termination rack. This includes all associated works of pulling out the cable from underground. The work shall be done as per location plans and instructions of Rly engineer at site."

14000

7

91199.5

... More
Laying of GI pipes in on bridges/culverts/concrete drain/ mountain ridges etc. with 20 suitable GI bend shall be provided where there is turning of pipe as per instructions of the site engineer. GI Clamps at every 2 m as shown in the drawing to be fixed. Suitable holes to be made in the pipe before laying as per instructions of the site engineer. 100 mm dia. Drg No SK 808

42

143

5531.31

... More
"Making of thermo shrink straight through/derivation/ transformer /PIJF cable joint for underground jelly filled cable 6 quad/4 quad/20 pair 10 pair etc. PIJF cable as per the instruction of Rly engineer at site."

30

1516

41748.82

... More
Horizontal boring of cable duct of minimum 2.0 mtr depth along with laying of 120 mm HDPE pipe for track crossing wirh minimum depth reckoned from bottom of the rail/Road crossing with 22 minimum depth reckoned from ground level. The work shall be done as per extent practice & instruction of site engineer.Preparation of site for Horizontal boring shall be carried out in presence of Railway Representative.HDPE will be supplied by Railway. Note:- Contractor shall provide all material required for boring and adequate nos.of labours for proper laying of cable into the bore.Cable shall be laid cautiously so that it should not get damage due to rough handling & pressure on cable.

3000

2610

7185291.15

... More
"Horizontal boring of cable duct of minimum 2.0 Mtr depth along with laying of 120mm HDPE pipe for Other locations with minimium depth reckoned from the ground level, The work shall be done as per extant practice & instructions of site engineer. Preparation of site for Horizontal Boring 23 shall be carried out in presence of Railway Representative. HDPE will be supplied by Railways. Note:- Contactor shall provide all material required for boring and adequate nos. of labours for proper laying of cables into the bore. Cable shall be laid cautiously so that it should not get damage due to rough handling & pressure on cable. B) BORING beyond 150 mtrs. Preparation of site for Horizontal Boring shall be carried out in presence of Railway Representative,"

1000

2366

2171116.95

... More
Shifting of existing Full Location Boxes coming in the alignment of doubling. The work 24 includes losing & removal of soil around location boxes by excavating soil around foundation, making of pit for shifting of location box horizontally opposite to railway track up to 0.5 to 1.0 mtr. This includes loosing of existing cable coils without any damage. The excavated soil shall be back filled after shifting of Locaion Boxes. Location box along with its foundation shall be shifted by push method with the help of jacks or by crane by contractors own expenditure under instructions of engineer in- charge at site. Any minor repairs in foundation due to patching shall also be carried out by contractor as per instruction of Engineer incharge. The work may affect train working hence the work shall be done as per margin only or during traffic block only.

30

5447

149947.12

... More
Shifting of existing Half Location Boxes coming in the alignment of doubling. The work includes losing & removal of soil around location boxes by excavating soil around foundation, making of pit for shifting of location box horizontally opposite to railway track up to 0.5 to 1.0 mtr. This 25 includes loosing of existing cable coils without any damage. The excavated soil shall be back filled after shifting of Locaion Boxes. Location box along with its foundation shall be shifted by push method with the help of jacks or by crane by contractors own expenditure under instructions of engineer in- charge at site. Any minor repairs in foundation due to patching shall also be carried out by contractor as per instruction of Engineer incharge. The work may affect train working hence the work shall be done as per margin only or during traffic block only.

5

4387

20127.79

... More
Laying of RCC half round cement pipe of approximate size (150/300 mm dia X 2 Meter length) inside the trench after laying of cable. Pipes shall be placed as per directives of engineer

600

36

20065.72

... More
"Painting of two coats of synthetic enamel paint over one coat of primer on the following after scraping & cleaning surface wherever necessary with contractor' own supply of 27 paints.Wherever required contractor shall apply coating of epoxy paint also as per instructions of site- in-charge.Epoxy paint will be supplied by Railways. NOTE:- The paint and primer should be from M/s Asian paints Co. Ltd.,. The paints will be primer (IS 5660 of 1970) the Aluminium synthetic black enamel (IS 2932 of 1974) brilliant white and yellow Painting two coats of enamel paint over one coat of primer. A) Apparatus Case Full Size."

40

435

15980.65

... More
"Painting of two coats of synthetic enamel paint over one coat of primer on the following after scraping & cleaning surface wherever necessary with contractor' own supply of 28 paints.Wherever required contractor shall apply coating of epoxy paint also as per instructions of site- in-charge.Epoxy paint will be supplied by Railways. NOTE:- The paint and primer should be from M/s Asian paints Co. Ltd.,. The paints will be primer (IS 5660 of 1970) the Aluminium synthetic black enamel (IS 2932 of 1974) brilliant white and yellow Painting two coats of enamel paint over one coat of primer. B) Apparatus case Half Size."

40

326

12000.53

... More
Lettering / Numbering of Signals, Point Machine, Track Lead Junction Boxes, Block Joints, Apparatus Cases etc. (each item to be taken as One Unit) This work will be carried out as per the standard practice being followed in Central Railway.

80

56

4157.38

... More
Lettering / Numbering Termination particulars, equipment names etc., legibly and neatly inside location boxes. A) Full Case.

40

263

9671.55

... More
Lettering / Numbering Termination particulars, equipment names etc., legibly and neatly inside location boxes. B) Half Case.

40

150

5506.1

... More
Fabrication and fixing of phenolic laminated/Fibre glass sheet in location box by 1 providing all fixtures as per Railway Drawing including fixing of PVC coated/with PVC pipe covered string rods at the back side for cable support with contractor's own materials. The work shall be done as per drg and arrangement similar to SK 783-1/2. with latest alterations & as per instructions of Rly engineer at site. A) Single Case Per44B 5400.00 14.05 75870.00 12.00 84974.40

18

2251

45394.88

... More
Excavation and Casting of Apparatus Case foundation with contractors Anchor bolts, cement, ballast and other materials.The required Scaffolding Ferma etc for Casting of foundation will have to be brought by the contractor at his own cost, A) Single Case as per Drg No SK 803

18

9887

199322.32

... More
Erection of Apparatus Cases. This includes filling of location foundations and plastering. A) Single Case

18

1098

22136.49

... More
Installation of Eqpt. (Relays, resistance, chargers batteries etc.as applicable) & wiring of the same in apparatus Cases as per location diagrams & circuit diagrams, as per Instruction of site incharge and practice. A) Single Case

18

1497

30194.04

... More
Installation of earth electrode assenbly as per Drg.No.RE/S&T/SIG/Tender/SK726/85 including earth wire connected through GI wire 8 SWG supported on M.S. flat of size 6mm x 40 mm to earth electrode as per drg. No.CR/S&T/SK-815 for sigg. Equipment such as lever frames, apparatus 6 case, signals, relay racks,block insruments, and etc. as per RE manual. The earth value should be less than 10 Ohms including the lead wire. The value should be measured in presence of Rly. supervisor. It should be documented and painted on earth enclosure made of concrete.( only earth electrode will be supplied by Railway). All other material required for provision of earthing will be brought by the contractor.

18

2528

50967.3

... More
Installation of unit earth as per RDSO/SPN/197/ver I or latest, to construct earthing of

18

5290

106653.25

... More
Excavation of cable trench as per cable route plan,1.0 mt. deep and 300mm wide along side the track in normal soil/strata, conforming to distances as per cable route plan and refilling after cable laying. This work includes covering of cable laid in trench by loose soil for a layer of 50mm 8 thickness after clearing of route,bushes etc.It shall be ensured that top of the cables laid is at a depth of 0.8 m or more If it is less,then the width and depth shall be suitably increased and accordingly proportuonate payment shall be made .In case depth of trench is not achievable due to site conditions,Proportionate payment will be made as per procedure.The work shall be done as per the extant practice on Central Railway and instructions of Railway Engineer at site.Drg No.SK 805

450

350

176400

... More
Excavation of cable trench as per cable route plan,1.0 mt. deep and 300mm wide along side the track in hard soil, conforming to distances as per cable route plan and refilling after cable laying. This work includes covering of cable laid in trench by loose soil for a layer of 50mm 9 thickness after clearing of route,bushes etc.It shall be ensured that top of the cables laid is at a depth of 0.8 m or more If it is less,then the width and depth shall be suitably increased and accordingly proportuonate payment shall be made .In case depth of trench is not achievable due to site conditions,Proportionate payment will be made as per procedure.The work shall be done as per the extant practice on Central Railway and instructions of Railway Engineer at site.Drg No.SK 805

72

583

47039.73

... More
Cutting of all types of Roads/ platforms (except concrete type ) for trenching and 10 excavation to depth of 300mmx300mm wide approx. and refilling after laying of RCC/GI/DWC pipe & to restore them to original condition. The work shall be done as per extant practice on C.Rly & instructions of Rly engineer at site.SK-807

15

2916

49000.06

... More
Digging of trench 1.0M deep from rail flange/road level (for LC) and 0.3 mtrs to 0.6 11 Mtrs wide and back filling after placing of DWC/RCC/GI pipe (Placing of DWC/RCC/GI pipe coverd separately) The ballast disturted be screened and dressed as required by Engineerin-charge or his representatives and road tarred immediately.Drg No.SK 806

60

583

39199.78

... More
Laying of DWC/RCC pipes alongwith collars/RCCHalf round pipe in trenches at places of track and road crossings, platform cuttings etc. 87B 25.00 Kilometre 5197.42 129935.50 12.00 145527.76

264

56

16809.41

... More
Laying of signalling/Power/Telecom cable of various cores/sizes in trenches.

-

-

13

... More
Whereever depth of 0.5 m cable trench is not feasible cable shall be protected as under :- Preparation of cement mixture 1:3:6 with contractor's own materials and spreading cement concrete mixture layer of 100 mm thick over the already laid cables in the excavated trench.

27

5329

161165.59

... More
Termination of cable cores on ARA terminal/Disconnecting link/fuse blocks, in the apparatus Cases/ cable termination rack. This includes all associated works of pulling out the cable from underground. The work shall be done as per location plans and instructions of Rly engineer at site.

5400

7

42940.8

... More
"Releasing of cables from old location boxes and taking it into new location boxes. This 16 includes excavating the earth to release the cables from old location box for taking it into new location. This also includes releasing the old location box and bringing it to nearest station / central cabin. Location(old) will be released only after ensuring all working cables have been shifted in New location." (PER LOCATION=NUMBERS)

10

2076

23254.56

... More
"Shifting of existing Full Location Boxes coming in the alignment of doubling. The work includes losing & removal of soil around location boxes by excavating soil around foundation, making of pit for shifting of location box horizontally opposite to railway track up to 0.5 to 1.0 mtr. This 17 includes loosing of existing cable coils without any damage. The excavated soil shall be back filled after shifting of Locaion Boxes. Location box along with its foundation shall be shifted by push method with the help of jacks or by crane by contractors own expenditure under instructions of engineer in- charge at site. Any minor repairs in foundation due to patching shall also be carried out by contractor as per instruction of Engineer incharge.The work may affect train working hence the work shall be done as per margin only or during traffic block only."

15

5447

91520.86

... More
"Shifting of existing Half Location Boxes coming in the alignment of doubling. The work includes losing & removal of soil around location boxes by excavating soil around foundation, making of pit for shifting of location box horizontally opposite to railway track up to 0.5 to 1.0 mtr. This 18 includes loosing of existing cable coils without any damage. The excavated soil shall be back filled after shifting of Locaion Boxes. Location box along with its foundation shall be shifted by push method with the help of jacks or by crane by contractors own expenditure under instructions of engineer in- charge at site. Any minor repairs in foundation due to patching shall also be carried out by contractor as per instruction of Engineer incharge. The work may affect train working hence the work shall be done as per margin only or during traffic block only."

5

4387

24570.17

... More
Laying of RCC half round cement pipe of approximate size (150/300 mm dia X 2 Meter length) inside the trench after laying of cable. Pipes shall be placed as per directives of engineer

1500

36

61236

... More
Painting of two coats of synthetic enamel paint over one coat of primer on the following after scraping & cleaning surface wherever necessary with contractor' own supply of paints. 20 Wherever required contractor shall apply coating of epoxy paint also as per instructions of site-in- charge. Epoxy paint will be supplied by Railways. NOTE:- The paint and primer should be from M/s Asian paints Co. Ltd.,. The paints will be primer (IS 5660 of 1970) the Aluminum synthetic black enamel (IS 2932 of 1974) brilliant white and yellow Painting two coats of enamel paint over one coat of primer. A) Apparatus Case Full Size.

18

435

8778.47

... More
Lettering / Numbering Termination particulars, equipments names etc., legibly and neatly inside location boxes. A) Full Case.

18

263

5312.76

... More
Excavation of cable trench as per cable route plan,1.2 mt. deep and 300mm wide along side the track in hard soil, conforming to distances as per cable route plan and refilling after cable laying. This work includes covering of cable laid in trench by loose soil for a layer of 50mm 1 thickness after clearing of route,bushes etc.It shall be ensured that top of the cables laid is at a depth of 0.8 m or more If it is less,then the width and depth shall be suitably increased and accordingly proportionate payment shall be made .In case depth of trench is not achievable due to site conditions, Proportionate payment will be made as per procedure. The work shall be done as per the extant practice on Central Railway and instructions of Railway Engineer at site.Drg No.SK 805

58400

209

12263416

... More
Excavation of cable trench as per cable route plan,1.0 mt. deep and 300mm wide along side the track in normal soil/strata, conforming to distances as per cable route plan and refilling after cable laying. This work includes covering of cable laid in trench by loose soil for a layer of 50mm thickness after clearing of route,bushes etc.It shall be ensured that top of the cables laid is at a depth of 0.8 m or more If it is less,then the width and depth shall be suitably increased and accordingly proportionate payment shall be made .In case depth of trench is not achievable due to site conditions,Proportionate payment will be made as per procedure.The work shall be done as per the extant practice on Central Railway and instructions of Railway Engineer at site.Drg No.SK 805

-

-

2

... More
"Laying of signalling/Power/Telecom cable of various cores/sizes in trenches."

-

-

3

... More
Laying of HDPE duct in trench and its protective work as per direction of site engineer.

-

-

4

... More
Blowing/Drawing of OFC cable in HDPE/DWC duct and protective work, as per direction of site engineer.

62900

13

820216

... More
Laying of DWC/RCC pipes alongwith collars/RCCHalf round pipe in trenches at places of track and road crossings, platform cuttings etc.

1032

56

58669.2

... More
Making of thermoshrink straight through/derivation/ transformer /PIJF cable joint for underground jelly filled cable 6 quad/4 quad/20 pair 10 pair etc. PIJF cable as per the instruction of Rly engineer at site.

98

1516

148642.48

... More
Where-ever depth of 0.5 m cable trench is not feasible cable shall be protected as under :- Preparation of cement mixture 1:3:6 with contractor's own materials and spreading cement concrete mixture layer of 100 mm thick over the already laid cables in the excavated trench

1000

5700

5700000

... More
Cutting of all types of Roads/ platforms (except concrete type ) for trenching and 9 excavation to depth of 300mmx300mm wide approx. and refilling after laying of RCC/GI/DWC pipe & to restore them to original condition. The work shall be done as per extant practice on C.Rly & instructions of Rly engineer at site.SK-807

2000

262

525000

... More
Supply of True RMS Multimeter Fluke Make model 289 or similar (Inspection by RDSO)

-

-

1

... More
Supply of cable fault locator (Inspection by RITES)

-

-

2

... More
TRMS Datalogging DMM Fine Tipmultimeter make-Rishabh 6016 or similar (Inspection By RITES)

6

21956

131736.84

... More
Supply of AC/DC clamp on Ammeter make-Amprobe LH41A (Inspection by Consignee)

-

-

4

... More
Supply of Insulation resistance tester with3-3/4 digital display suitable for 100 V make Motwane D2K-M or Rish Insu MIT 30 . (Inspection by Consignee)

6

8213

49280.4

... More
Bumpless Automatic power source changeover device DC-20-150V, 45A(2 input sources) Model no. PT-RSA-HL-DC-03. (Inspection By RITES)

15

54516

817740

... More
Installation of item Automatic changeover unit of signal/ Track /Point supply of 32A, DC consisting of 3TC44 contactors or similar , LED Lamp, Push button terminals, VSR, polarity switches. (Inspection By RITES)

15

5325

79888.05

... More
"Transporting and supply and installation of concrete ( RCC) route indicator at interval 8 of 50 Mtrs. As per technical specification .They should be of standard RCC with letter one side C.R. and the other side ""S&T cable'' as per drawing SK12/10 of RVNL/SC in case of telecom quad cable joint location . It shall be printed with red colour. (Inspection by Consignee)"

100

1100

110000

... More
Chase cutting 500mm deep in hard rocky area as per DRG Ni- CORE/S&T/ALD/SK/579/04 per meter. (Inspection by Consignee)

1000

303

303570

... More
Supply & testing of precision Cable locator / Route tracer with MXT4 Transmitter & 10 Signal Clamp of make CSCOPE U.K or its equivalent as per enclosed specification. ACCEPTED FIRM'S OFFER MAKE - CSCOPE, UK : MODEL -MXL4 . PURCHASE PROOF FROM OEM/ AUTHORISED DEALER AND OEM'S WARRANTY CERTIFICATE ARE TO BE SUBMITTED ALONG WITH SUPPLY. MATERIAL IS TO BE SUPPIED AS PER TENDER DESCRIPTION AND SPECIFICATIONS . (Inspection By RITES)

5

389400

1947000

... More
Supply of TELEMETRICS Rechargeable Handheld Telecom TDR Cable Fault Locator 1 year Brand: TELEMETRICS (Detailed Description/Specification as per Product # 1 of GeM Contract No. GEMC511687710737935 dt.17/02/2023) (Inspection by RITES)

5

201665

1008325

... More
Deployment of Manpowerlike unskilled Labour to work in emeigmcies o r as enquired during cable shifting, finding the existing cable route, shifting & placing of materials in depot etc.

600

558

335040

... More
Deployment of Manpowerlike skilled Labour t o work i n emeigmcies o r as enquired during cable shifting, finding the existing cable route, shifting & placing of materials in depot etc.

300

617

185211

... More
Supply of ISI marked HDPE Pipe Nominal diameter 110mm ,Material grade : PE 100, colour : Black, Length of pipe should be 6 meters each . Make : Capital, Kasta, Kissan, Finolex, Samarath or Similar. (Inspection By RITES)

900

179

161253

... More
Supply of VDU Pannel 42" for EI system as per TS. Make: Samsung, Sony, LG or superior. (Inspection by RITES)

15

29999

449985

... More
Supply of cable route marker as per RST/C/203 of FRP. (Inspection by Consignee)

-

-

16

... More
Supply of True RMS Multimeter Fluke Make model 289 or similar (Inspection by RDSO)

-

-

1

... More
Chase cutting 500mm deep in hard rocky area as per DRG Ni- CORE/S&T/ALD/SK/579/04 per meter (Inspection by Consignee)

500

303

151785

... More
Transporting and supply and installation of concrete ( RCC) route indicator at interval 3 of 50 Mtrs. As per technical specification .They should be of standard RCC with letter one side C.R. and the other side "S&T cable'' as per drawing SK12/10 of RVNL/SC in case of telecom quad cable joint location . It shall be printed with red colour. (Inspection by Consignee)

10

1100

11000

... More
Supply of 48 fibre OFC Splice enclosure FIBRE OPTIC FIBRE SPLICE STRAIGHT JOINT 1 ENCLOSURE ( SJC ) complete with all accessories as per RDSO/SPN/TC/68/2014, rev. 3 or specs for 24 fiber ofc cable with later amendment. Accepted Make / Brand - Micro Engineering. (Proportionate rate has been taken)(Inspection by RITES)

30

3795

113855.7

... More
"Supply of 24 fibre straight joint closure (SJC) complete with all accessories as per 2 RDSO Spec. No.RDSO/SPN/TC/68/2007, Rev.0 Amendment No.1.1 or latest ammendments and as per or TEC Spec.G/OIJC/02/02 Sept 2003 or latest of Raychem make model FOSC 400 B4 24F or TVS ICS make model 1500-L1 83-XX or Birla VXL make model VT-200 or 3M make model 2179 CD." (Inspection by RITES)

36

3417

123013.8

... More
Splicing/Dropping/Termination of each fiber/pigtail in LIU/IO BOX/TERMINAL JOINTS 3 through fusion splicing for termination of OFC cables. The Fibers terminated shall be tested and test report (Hard copy and Soft copy ) shall be submitted to the Railways site In-charge for records. Each fiber shall be properly marked with necessary ferrules/tags, (For One fiber rate is 115.63 so for one joint ( 2x48) rate will be 11100.48) (Proportionate rate has been taken) (Inspection by RITES)

25

6849

171248.75

... More
"Splicing (Jointing 2X24 F OFC ) and testing of 24 fibre OF Cable and making the splice joint as per direction of site engineer with contractors own splicing machine & tools. Splice loss of each fibre should be less than or equal to 0.05db splice reflectance should be better than 60 db." (Inspection by RITES)

18

6301

113418

... More
Supply of OFC splicing machine with all related accessories and power supply backup arrangement of reputed make. (Inspection by RITES)

5

235000

1175000

... More
Supply of UNIWAY 24 decibel Single ModeOptical Time Domain Reflectometer(OTDR) (Inspection by RITES)

5

66640

333200

... More
"Supply of Optical Power Meter optical light source & visual fault locator 10mw optical 7 power meter fiber optical power meter with laser optical power meter with vfl visual fault optical power meter with vfl visual fault locator fiber optic cable tester optical laser source optical light source meter" (Inspection by RITES)

5

18000

90000



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.