Central Railway Tender

... More
Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.

Central Railway Tender

Works
Ireps
Opening Date16 Apr 2025
Closing Date13 May 2025
Tender Amount₹ 89,91,439.37 
Notes
Download

Costs

Summary

Signal And Telecommunication Work In Connection With Requirement Of Modifications In Circuit For Removing Operational Constraints At Miraj Station Of Pune Division.

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply of PVC Indoor Cable 1x60x0.6mm dia Colour coding of insulation of inner core shall be in six colour viz Blue, Red, Grey, Green, Brown & Black conforming to IRS 76/89 (Amd.3) or latest. (Inspection by Consignee)

0.5

-

172963.76

... More
Supply of PVC Indoor Cable 1x40x0.6mm dia Colour coding of insulation of inner core shall be in eight colour viz Blue, Red, Grey, Green, Brown, Black, Yellow & White conforming to IRS 76/89 or latest. (Inspection by Consignee)

0.5

-

113468.29

... More
Supply of Indoor Jumper Wire of various colour as per Railways standard practice of type ATC 1 x 0.6 mm dia.conforming to IRS 76/89 (Amd.3) or latest. (Inspection by Consignee)

10

9745

97451.1

... More
Supply of Indoor Jumper Wire ATC 1 x 1 mm dia. conforming to IRS 76/89 (Amd.3) or latest. (Inspection by Consignee)

0.2

-

3017.77

... More
Supply of PVC flexible copper cable single core multistrand 1 x 16 Sq.mm (126 8 conductor each diameter 0.40 +/- 0.01) as per IS 2465/1984 & IS:694/2010 with latest amendment if any with insulation thickness of 1.0mm nominal conductor resistance 1.121 ohms/Km and test parameters are as per IRS (S)76/89 (Amd.3). (Inspection by Consignee)

0.5

-

120761.26

... More
Supply of wire 16/0.2 (Blue, Red, Grey, yellow, Brown, Black, White as per site engineer instruction) finolex/polycab/delton make. IRS S-76/89 (Amd.3), BS: 4808 Part-2. Wire to be procured from RDSO approved vender. (Inspection by Consignee)

2

7415

14830.34

... More
Supply of Rubber Mat 5mm thick for use in signalling installation. (Inspection by Consignee)

50

149

7451.5

... More
Relay base plate complete with amphanols, code pins, fixing screws etc.suitable for 11 Metal to Metal K-50 mini groups/ECRs of Siemens Make or functional equivalent of other makes. Note : Relay base plates, are to be procured from Relay manufacturer(OEM). Manufacturer's Certificate for procurement and guarantee in this regard should be furnished. The payment to be released only after Manufacturer's Certificate is submitted. (Inspection by Consignee)

60

717

43044

... More
Major Relay Group Base Plates, complete with fedlisters (20 No per base plate), guide 12 rails and other accessories suitable for major group of Siemens make or functional equivalent of other makes. Note : Relay base plates, are to be procured from Relay manufacturer(OEM). Manufacturer's Certificate for procurement and guarantee in this regard should be furnished. The payment to be released only after Manufacturer's Certificate is submitted. (Inspection by Consignee)

2

15462

30924.46

... More
Base plates for Siemens Point chain group or its functional equivalent. Note : Relay 13 base plates, are to be procured from Relay manufacturer(OEM). Manufacturer's Certificate for procurement and guarantee in this regard should be furnished. The payment to be released only after Manufacturer's Certificate is submitted. (Inspection by Consignee)

2

9445

18890.08

... More
Supply of Shunt Signal Group Siemens make [No. A-RT-RG-A065] or functional equivalent without base plates (suitable for LED Signal). (Inspection by RDSO)

2

66131

132262.06

... More
Supply of Point Group RRI, Siemens (No.RSSK 3515/19) or functional equivalent without base plates. (Inspection by RDSO)

2

97124

194249.14

... More
Supply of Point Chain Group Siemens make (No. RSSK 3515/3)or functional equivalent without base plates. (Inspection by RDSO)

1

37347

37347.33

... More
Supply of Time Element Relay (Clock work type) AG timer Siemens Make (No RSSK 30/0052) or GIC make or functional equivalent. (Inspection by Consignee)

10

8920

89205.8

... More
Supply of Plug In type Relay Metal to Metal type neutral relay mini groups (Non AC 18 Immunised) Siemens make (No. RSSK 30/0011) (Ref. IRS:S46/74 with Amd. 1 & firms specification) or functional equivalent without base plates.Contact configuration 5F/3B or 6F/2B or 4F/4B to be specified by Engineer incharge. (Inspection by RDSO)

25

7021

175529

... More
Supply of Plug In type Relay Metal to Metal type neutral relay mini groups (AC 19 Immunised-1) Siemens make (No. RSSK 30/0078-1) (Ref. IRS:S46/74 with Amd. 1 & firms specification).or functional equivalent without base plates.Contact configuration 5F/3B or 6F/2B or 4F/4B to be specified by Engineer incharge. (Inspection by RDSO)

10

8538

85386.7

... More
Supply of Plug In type Relay Interlocked Siemens make (No. RSSK 30/0012) or functional equivalant (Ref. IRS:S46/74 with Amd. 1 & firms specification). Contact configuration 4F/4B. (Inspection by RDSO)

10

8016

80165.5

... More
Supply of Metal-To-Metal Universal LED type ECR Siemens make (type A-RT-RG-A064) or functional equivalent without base plate, should be suitable for working with LED based signal lighting unit. IRS:S:46 & STS/E/RELAYS/AC LIT LED SIGNAL/09-2002 Amd.1. (Inspection by RDSO)

15

6838

102580.35

... More
Supply of QNA1 AC immunised relay, 8F-8B, 24 VDC along with plug board, retaining clip and connectors confirming to BRS : 931A, IRS:S60, IRS:S34 & IRS:S23 (Inspection by RDSO)

-

-

22

... More
Supply of QSPA1 relay, 24VDC, slow to pick up, 8F-4B, along with plug board, retaining clip and connectors conforming to BRS:933A, IRS : S60, IRS:S34 & IRS:S23 (Inspection by RDSO)

15

5079

76190.7

... More
Supply of QTA2 AC immunised track relay, 9 Ohm, 2F.1B, along with plug board, retaining clip and connectors conforming to BRS:939A, 966 & Appendix F2, IRS:S34 & IRS:S23 (Inspection by RDSO)

15

4440

66610.95

... More
Supply of QBAT track Relay, AC immunised, 2F-2B contacts, 9 ohms. complete with plug board, retaining clip & connectors as per RDSO / SPN/84 Ver 2.0 or latest. (Inspection by RDSO)

10

7597

75976.6

... More
Supply of Domino units with cover plate as per approved panel diagram, each of size 54 x 34mm completely wired up similar to Siemens make. Each domino units should have all the 15 contact terminals wired up. (Inspection by Consignee)

60

1719

103197

... More
Supply of INDICATIVE TYPE OF FUSE INSERTS. IRS S:78-92 (a) With holder 1.6 A (System, Rapid or Malnad make). (Inspection by Consignee)

50

91

4597.5

... More
Supply of INDICATIVE TYPE OF FUSE INSERTS. IRS S:78-92 (b) With holder 0.6 A (System, Rapid or Malnad make). (Inspection by Consignee)

50

88

4440

... More
Supply of INDICATIVE TYPE OF FUSE INSERTS. IRS S:78-92 (c) With holder 6 A/10A ( D- Type Bharat Linder, L&T or HEVELLS Make). (Inspection by Consignee)

50

311

15566

... More
Supply of INDICATIVE TYPE OF FUSE INSERTS. IRS S:78-92 (d) Without holder 1.6 A (System, Rapid or Malnad Make). (Inspection by Consignee)

50

26

1324

... More
Supply of INDICATIVE TYPE OF FUSE INSERTS. IRS S:78-92 (e) Without holder 0.6 A (System, Rapid or Malnad Make). (Inspection by Consignee)

50

26

1324

... More
Supply of INDICATIVE TYPE OF FUSE INSERTS. IRS S:78-92 (f) Without holder 6A/10A (D-type Bharat Linder, L&T or HEVELLS Make). (Inspection by Consignee)

50

110

5505.5

... More
Resin cored wire as per specification No. IS:1921-1975 with Alloying element percentage as 63% SN (Tin) and / 37% Pb (Lead) with percentage of various impurities not exceeding 33 the values Sb (Antimony) 0.2% maximum , Cu (Copper) 0.1% maximum, As (Arsenic) 0.05% maximum, Fe (Iron) 0.02% maximum & other impurities mainly Al, Zn & Cd shall be limited. The flux shall be free from corrosive action as per clause 5.2 & flux percentage may be used as per requirement. (Inspection by Consignee)

25

1441

36027.25

... More
Lacing thread rolls, black, wax coated (100 mtrs). (Inspection by Consignee)

-

-

34

... More
Supply of Shunt Signal Post with Base (GI Pipe of 80 mm Dia of min. 1 meter length.). (Inspection by Consignee)

5

3119

15599.9

... More
Supply of Cast iron Shunt signal surface base 80 mm as per spec No.IRS S 10 and Drg No.2011/M with latest amendments, as per RDSO Drg No. SA-23156/Drg.No.RST/11413 as per extent C.Rly practice (Inspection by Consignee)

-

-

38

... More
Supply of Signal No.plates. as per Drg No RST-11393 / SK-842 (Inspection by Consignee)

15

600

9003

... More
Supply of Stop Board/IB Board as per RST-11791 (STOP BOARD)/ RDSO Drg No.7235/B as per extent C.Rly practice. (Inspection by Consignee)

10

3433

34337.8

... More
Supply of Hand Cuff Locks/ Godrej Navtal lock with Three common keys. (Inspection by Consignee)

50

329

16464

... More
Supply and Fixing of RE Protective Screens of expanded metal 12 SWG of size 1200 x 1500 mm on signals as per extant practice & as per instruction of Rly engineer at site. DRG.No.SK- 844. (Inspection by Consignee)

1

6013

6013.96

... More
Supply of Phenolic 10mm thick sheet, grade P3 in standard size of 1.22X1.22 Mtr as per spec. No IS 2036 of 1995. (Inspection by Consignee)

12

5506

66079.44

... More
Supply of ARA Terminal blocks with links made of PBT Specn No.IRS/75/2006(Rev-2) with latest amendments and RDSO Drg.No.SA-23741A Alt.4, SA-23745 Alt.5, SA-23746, SA-23748 Alt.4 & SA-23756A Alt.3. (Inspection by RDSO)

1500

76

114225

... More
Supply of cartridge fuse block made of PBT as per RDSO Drg No SA-23748 Alt 4, SA- 23749 & Spec No IRS S 75/2006 with latest amendment. Fuse block shall be suitable for round head type voltage fuses. (Inspection by RDSO)

200

170

34178

... More
Supply of round head type non detoriating type low voltage cartridge fuse as per Specn No IRS/S/78/92 with latest amendments 2A/4A/6A capacity (Inspection by RDSO)

100

73

7355

... More
Supply of Tik-tak, piano type switches,5 A (as per IS Specification). (Inspection by Consignee)

8

35

280.32

... More
Supply of three pole plug and socket 5 Amp (as per IS Specification).(Inspection by Consignee)

8

242

1936.96

... More
Supply of Lamp 110V/24W, 2 Pin for Loc. (Inspection by Consignee)

-

-

49

... More
Supply of Apparatus Case with godown locks with detachable handle on both the doors. a) Single Case asper Drg. No.SK 783-1 & 2 with latest alteration. (Inspection by Consignee)

5

16801

84007.85

... More
Supply of Apparatus Case with godown locks with detachable handle on both the doors. b) Half Case as per Drg. No.SK 783-1 & 2 with latest alteration. (Inspection by Consignee)

2

13481

26962.02

... More
Supply of earth electrode assembly as per Drg. No. CR/S&T/SK-815 (Inspection by Consignee)

12

1214

14578.56

... More
Maintenance Free Earth as per RDSO/SPN.197/ 2008 or latest consisting of : 1) Copper 53 bond steel electrode 3 Mtr long 17mm dia with copper bonding thickness of min. 250 micron & UL listed & marked-01 No.2) Earth enhancement compound RDSO Approved in sealed bag of 10Kgs - 03 No. 3) Copper strip 150 x 25x 6mm - 02 No. 4) Copper strip 300 x25 x 6mm - 01 No. 5) 35 Sqmm Copper Cable to connect earth electrode to MEEB - 15 Mtr Approx.(Inspection by RDSO)

5

20463

102315.85

... More
Supply of Copper Tape 25x6 mm(Bonding ring conductor) mounted on insulated standoff (1 round).(Inspection by Consignee)

50

915

45755.5

... More
Supply of Microprocessor based universal earth resistance sensing unit 12 channel AC/DC as per RDSO/SPN/256/2002 with latest amendments. (Inspection by RDSO)

5

167818

839091.45

... More
Supply of Track Lead Junction Boxes as per C.Rly Drg. No.RST 11509made from fiber glass along with terminal blocks. (Inspection by Consignee)

-

-

56

... More
Supply of adjustable Track Feed Resistance disc type 7.5/15/30 ohms as per RDSO Drg. No. SA 20161-66/M(Adv) with latest amendments (with Phenolic moulded base). (Inspection by Consignee)

20

1482

29640.2

... More
Supply of Track feed battery chargers,110V AC input 2, 4 to 6 V DC Output to Specn.No.IRS.89/2013 Ver.1.0 with latest amendments. Charger shall be suitable for charging 80 AH battery.(Inspection by RDSO)

20

2796

55921.2

... More
Supply of Channel Pins single groove, galvanised, 7 mm suitable for 4mmdia bonding wire as per spec No. IRS:S 17-75 Revision 3. (Inspection by Consignee)

10000

2

23100

... More
Supply of PVC jacketed wire rope for Track Lead connections. PVC jacketed wire rope 60 should be of Galvanised steel wire rope 6 mm dia (6x19stranded wire with steel core of 6 mm dia) sheathed with PVC 2mm wall thickness, overall thickness being 10mm. PVC sheath should be made of type 6 compound as per IS 5831 of1984 Reaffirmed 2001 and steel wire rope as per IS: 2266:2019.Reclaimed or recycled material shouldnot be used. (Inspection by Consignee)

6000

59

359640

... More
Supply of 8 SWG GI wire (4mm dia)suitable for track circuit rail bonding. As per IRS Specification S:13@ 45>46@ (Inspection by Consignee)

150

99

14983.5

... More
Supply of Hydrometer, Exide make or similar for measuring specific gravity of Battery Graded acid with mounting stand in location Boxes.Consignee inspection under manufacturer certificate. (Inspection by Consignee)

10

326

3263.3

... More
Supply of William stretcher nylon insulation set suitable for ground connection as per RDSO drg No T-10367, T-10368, T-10384 as applicable and to the spec IRS S 23 & 40/84 with latest amendements . (Inspection by Consignee)

50

611

30596

... More
Supply of Tongue attachment nylon insulation set consisting of one insulating plate as per Drg no: RST-106961 & 3 nos of Ferrules with collars to suite rodding supplied as per RDSO spec & Drg.no: RST-10692 (Inspection by Consignee)

50

389

19460.5

... More
Supply Gauge Tie plate nylon insulation as per RDSO drg No: T- 10372 Alt2, T- 10368, T- 10371 Alt2, T-15083/88/Alt2 & T-11690/Alt2 and to the spec IRS S 23 & 40 with amendement 01 or latest amendements. (Inspection by Consignee)

50

280

14042.5

... More
Supply of GI bend pipe, 'B' class, 50mm dia for cable entry in point machines, alongwith required fixing arrangements as per standard practice on Central Railway. As per Drg No. RST.11835. (Inspection by Consignee)

50

290

14541

... More
Supply of GI pipe, inner dia. 100mm dia. B-class as per spec. No.IS 1239 PT. 1/2004 or latest with sockets and fittings. TATA/JINDAL/ZENITH BIRLA make. (Inspection by Consignee)

120

1079

129544.8

... More
Supply of DWC HDPE pipe with one snap fit coupler and 'O' ring fire resistant, anti rodent, in 6 meter length of size 120 mm outer dia as per RDSO/SPN/204/2011 Ver. 1.1 with Amd.1 or latest. (Inspection by Consignee)

120

337

40453.2

... More
Supply of RCC pipes half round of size 150mm dia outer and 100 mm dia internal 1 mtr long matching to IS No. 458/2003 amendment-1 with Rev.4. (Inspection by Consignee)

200

232

46460

... More
Supply of Modular terminal block of 2.5 sq.mm 2 in 2 out type disconnect type 70 terminal along with as per RDSO/SPN/189/2004 Rev 3.0. The current capacity of 16 Amps and more. The terminal should have marking at centre to view description from front. Material to be procured from RDSO approved firms only. (Inspection by RDSO)

1500

131

197970

... More
Supply of DIN Channel for the terminals 1 Mtrs each. (Inspection by Consignee)

-

-

71

... More
Supply of End plates for modular terminal block. (Inspection by Consignee)

-

-

72

... More
Supply of End Clamp for modular terminal block. (Inspection by Consignee)

-

-

73

... More
Supply of Marker Card as per customer spec. (10x10) (Inspection by Consignee)

-

-

74

... More
Fuse terminal block with LED indication upto 2.5 sq.mm screw type one in one out (suitable for (400 mA, 630mA, 1A. 1.6A, 2A, 4A, 6.3A & 10A) as per RDSO/SPN/189/2004.(without fuse) (Inspection by Consignee)

100

209

20922

... More
End plate for through terminal block with LED indication. (Inspection by Consignee)

-

-

76

... More
Fuse links of (400 mA, 630mA, 1A. 1.6A, 2A, 4A, 6.3A & 10A) (Inspection by Consignee)

-

-

77

... More
Shorting link isulated Grey in colour. (Inspection by Consignee)

-

-

78

... More
Operating tool (operating tool, screw driver & stripper) as per item no.3.1 of Chapter- III. (Inspection by Consignee)

1

9963

9963.56

... More
Supply of VHF 25W transreceiver (synthesised) set complete consisting of Analog Set as per CR specification. (Inspection by Consignee)

2

27382

54765.16

... More
Supply of 4.5 Kg CO2 type fire extinguisher alog with all accessaries, extinguisher testig certificate has to be supplied along with - Supply of ISI marked Carbon di Oxide type (BC) fire 81 extinguisher of 4.5 Kg capacity confirming to IS 2878:2004 from seamless cylinder, with IS marked control value, high pressure mtr., Long discharge hose and horn complete with initial gas charged with carrying handle and wall mounting braket etc., as required by Site Engineer. (Inspection by Consignee)

20

5774

115490.2

... More
Supply of Permanently Lubricated HDPE Telecom duct of size 50/42 mm and 82 accessories as per latest Specification TEC GR No. GR/TX/CDS-008/03/March 11 with latest amendment" for OFC cable of size 24 fibre armoured in length of 1000 mtrs/roll. Duct to be supplied from TEC approved sources. (Inspection by Consignee)

0.5

-

42023.78

... More
Installation of Relay Rack Assembly including IDF pillars if any complete with wall 1 supports, scaffolding, ladders, runway for cables, Relay/Relay group base plates, fixing of Tag blocks etc. The work shall be done as per approved plan, extant practice on C. Railways & the instructions of Rly engineer at site. (Inspection by Consignee)

2

1768

3537.2

... More
Installation of Cable Termination Racks Assembly complete including wall supports, 2 scaffolding Disconnecting links/ARA terminal, 96 way tag block cover & other necessary accessories etc. The work shall be done as per approved plan, extant practice on C. Railways & the instruction of Rly engineer at site. (Inspection by Consignee)

2

1355

2711.64

... More
Termination of cable cores on ARA terminal/disconnecting links in the cable 3 termination rack. This includes all assosiated works of pulling out the cable from under ground, peeling off insulation, dressing of cable core supported on sting rod with contractors own material. The work shall be done as per instructions of Rly engineer at site. (Inspection by Consignee)

3000

13

39420

... More
Circuit wiring/jumpering as per circuit diagrams in the relay racks/IDF rack tagblocks. This includes preparation of Jumper sheets by wire man duly checked by firm's site supervisor & wire to wire testing as per circuit diagram. Any wrong jumper done by wireman will not be paid & correction shall be done free of cost. Jumper wires will be issued by Railways. Good quality solder rosin core to be supplied by contractor for soldering of Jumper wires. Soldering of jumper wires to be done after completion of testing by Railways. (Inspection by Consignee) [Unit to be read as - Jumper].

-

-

5

... More
Lettering & Numbering of detail and description writing of particulars of terminations & 11 equipments on relay rack, relays, cable termination rack, battery & power equipments, IPS, operating panel, axle counter etc constituting entire system with contractor's own paint and writing material ("Asian/Dulux" make enamel paints to be used). The work shall be done as per extant practice on C.Rly & instruction of Rly engineer at site. (Inspection by Consignee)

20

387

7751.8

... More
Preparation of cable route plan, cable coreage plan, location particulars, Cable termination rack particulars, cable meggering report, earth resistance particulars, Traction bonding diagram, 1/2 wire count sheet and any other drawing in Autocad in A3/A4 size.The contractor shall initially supply 3 sets of circuits complete for approval of Railways. Railways will return one set to the 12 contractor duly approved with alterations/corrections if any. The contractor shall incorporate Railways alterations/corrections in the tracings without any deviation and submit all tracings complete in all respects to the Railways . This includes submission of final cable route plan as per laid cable duly measured at every 30m clearly indicating distance of laid cable from fixed point of reference & indicating all track crossings and tail cables. This also include designing of cable coreage plan based upon I.P in consultation with engineer-in-charge. (i) For big yards (> 100 routes) (Inspection by Consignee)

1

58842

58842.92

... More
Preparation of cable route plan, cable coreage plan, location particulars, Cable termination rack particulars, cable meggering report, earth resistance particulars, Traction bonding diagram, 1/2 wire count sheet and any other drawing in Autocad in A3/A4 size.The contractor shall initially supply 3 sets of circuits complete for approval of Railways. Railways will return one set to the contractor duly approved with alterations/corrections if any. The contractor shall incorporate Railways alterations/corrections in the tracings without any deviation and submit all tracings complete in all respects to the Railways . This includes submission of final cable route plan as per laid cable duly measured at every 30m clearly indicating distance of laid cable from fixed point of reference & indicating all track crossings and tail cables. This also include designing of cable coreage plan based upon I.P in consultation with engineer-in-charge. (ii) For small/medium yards (<= 100 routes) (Inspection by Consignee)

-

-

13

... More
Design and supply of Detailed Signalling Circuits including Panel diagram(if required) , Route section Plan , Selection Table , Fuse & Negative Tag. Analysis , Contact analysis , Relay Rack Arrangement and wire count sheets etc. in A3 size.Completion circuit shall be plotted in AutoCAD. The contractor shall initially supply 2 sets of circuits duly signed by the circuit designer having substantial experience on design side for making such circuits, complete for approval of Railways. Railways will 14 return one set of circuit to the contractor duly approved with alterations /corrections, if any. The contractor shall incorporate Railway's alterations/corrections in the original tracings & CD without any deviation and submit two copies of the modified circuits. Original tracings so modified & final CD complete in all respects alongwith 6 sets of final approved circuits (out of which one set shall be supplied in transparent bags. Only two sheets of circuits shall be placed in one bag each ) shall be submitted to the Railways in case there are no further alteration suggested by Railways. This also includes modification in yard. (i) for stations having Routes <= 50 (Inspection by Consignee)

1

110643

110643.82

... More
Design and supply of Detailed Signalling Circuits including Panel diagram(if required) , Route section Plan , Selection Table , Fuse & Negative Tag. Analysis , Contact analysis , Relay Rack Arrangement and wire count sheets etc. in A3 size.Completion circuit shall be plotted in AutoCAD. The contractor shall initially supply 2 sets of circuits duly signed by the circuit designer having substantial experience on design side for making such circuits, complete for approval of Railways. Railways will 15 return one set of circuit to the contractor duly approved with alterations /corrections, if any. The contractor shall incorporate Railway's alterations/corrections in the original tracings & CD without any deviation and submit two copies of the modified circuits. Original tracings so modified & final CD complete in all respects alongwith 6 sets of final approved circuits (out of which one set shall be supplied in transparent bags. Only two sheets of circuits shall be placed in one bag each ) shall be submitted to the Railways in case there are no further alteration suggested by Railways. This also includes modification in yard. (ii) for major yards and stations having more than 200 routes (Inspection by Consignee)

1

1288556

1288556.77

... More
Excavation and Casting of Main signal foundation as per Drg No SK 801 with 16 contractor's own materials including cement and anchor bolts of standard size. The required scaffolding Ferma etc for Casting of foundation will have to be brought by the contractor at his own cost. (Inspection by Consignee)

5

10526

52631.55

... More
Excavation and Casting of Shunt signal foundation as per Drg No SK 802 with 17 contractor's own materials including cement and anchor bolts of standard size. The required scaffolding Ferma etc for Casting of foundation will have to be brought by the contractor at his own cost. (Inspection by Consignee)

5

3047

15239.65

... More
Erection of CLS Post with Surface base and signal unit on top or on OFF set Bracket, 18 fixing of front and back staging, ladder and guards, signal name plates/boards if any with contractors own brackets and fixing materials. This also includes erection of auxiliary signals like calling on, shunt signal if any. The work shall be done as per instructions of Rly engineer at site. (Inspection by Consignee)

5

4015

20077.5

... More
Erection of shunt signal with Surface Base, Post, Signal unit and fixing of No.plates. The work shall be done as per instructions of Rly engineer at site. (Inspection by Consignee)

5

553

2769.5

... More
Fixing of Jn.Route Indication 1-Way/2-Way/3-Way on the top of the signal post. (Inspection by Consignee)

4

878

3514.56

... More
Fixing of Stop Board, Block section limit Board, goods warning board with contractors own material. The work shall be done as per instruction of Rly engineer at site. (Inspection by Consignee)

10

636

6365.5

... More
Termination of tail cable on Shunt signal units and wiring with contractor own material, fixing of lenses etc. The work shall be done as per instruction of Rly engineer at site. (Inspection by Consignee)

-

-

22

... More
Supply and fixing of Protective screen of expanded metal 12 SWG of size 1200 x 1500 mm on signals as per standard practice. (Inspection by Consignee)

3

4969

14908.32

... More
Fabrication and fixing of phenolic laminated/Fibre glass sheet in location box by 24 providing all fixtures as per Railway Drawing including fixing of PVC coated/with PVC pipe covered string rods at the back side for cable support with contractor's own materials. The work shall be done as per drg and arrangement similar to SK 783-1&2. with latest alterations & as per instructions of Rly engineer at site. (a) Single Case (Inspection by Consignee)

5

2361

11807.9

... More
Fabrication and fixing of phenolic laminated/Fibre glass sheet in location box by 25 providing all fixtures as per Railway Drawing including fixing of PVC coated/with PVC pipe covered string rods at the back side for cable support with contractor's own materials. The work shall be done as per drg and arrangement similar to SK 783-1&2. with latest alterations & as per instructions of Rly engineer at site. (b) Half Case (Inspection by Consignee)

2

2081

4163.22

... More
Excavation and Casting of Apparatus Case foundation with contractors Anchor bolts, 28 cement, ballast and other materials. The required scaffolding Ferma etc for Casting of foundation will have to be brought by the contractor at his own cost. (i) Single Case as per Drg No . SK-803 (Inspection by Consignee)

5

10369

51846.75

... More
Excavation and Casting of Apparatus Case foundation with contractors Anchor bolts, 29 cement, ballast and other materials. The required scaffolding Ferma etc for Casting of foundation will have to be brought by the contractor at his own cost. (ii) Half Case as per Drg No . SK-804 (Inspection by Consignee)

2

10166

20333.68

... More
Erection of Apparatus Cases. This includes filling of location foundations and plastering (i) Single Case (Inspection by Consignee)

5

1151

5758.05

... More
Erection of Apparatus Cases. This includes filling of location foundations and plastering (ii) Half Case (Inspection by Consignee)

2

883

1766.98

... More
Installation of Eqpt. (Relays, resistance, chargers batteries etc.as applicable) & wiring of the same in apparatus Cases as per location diagrams & circuit diagrams, as per Instruction of site incharge and practice. (i) Single Case (Inspection by Consignee)

5

1687

8438.9

... More
Installation of Eqpt. (Relays, resistance, chargers batteries etc.as applicable) & wiring of the same in apparatus Cases as per location diagrams & circuit diagrams, as per Instruction of site incharge and practice. (ii) Half Case (Inspection by Consignee)

2

1146

2293.88

... More
Installation of earth electrode assenbly as per Drg.No.RE/S&T/SIG/Tender/SK726/85 including earth wire connected through GI wire 8 SWG supported on M.S. flat of size 6mm x 40 mm to earth electrode as per drg. No. CR/S&T/SK-815 for sigg. Equipment such as lever frames, apparatus 34 case, signals, relay racks,block insruments, and etc. as per RE manual. The earth value should be less than 10 Ohms including the lead wire. The value should be measured in presence of Rly. supervisor. It should be documented and painted on earth enclosure made of concrete.( only earth electrode will be supplied by Railway). All other material required for provision of earthing will be brought by the contractor. (Inspection by Consignee)

12

2908

34903.56

... More
Installation, wiring, testing & commissioning of Microprocessor baased universal earth leakage detector unit 12 channel AC/DC. (Inspection by Consignee)

-

-

35

... More
Erection, Fitting and Rail connection of Track Lead Juntion Box on two 36 supports(M.S.angle) with contractor's fixing material and PVC jacketed wire for track lead connection including angles of size 40 x 40 x 5 mm 1200 mm length. This will include drilling of holes for track lead/side connections on rail. The work shall be carried out as per Drg. No. SK-845 or/& instructions of Rly engineer at site. (Inspection by Consignee)

50

1501

75089.5

... More
Provision of bonding with contractor's PVC jacketed wire rope for Track Lead connection. PVC jacketed wire rope should be of Galvanised steel wire rope 6mm dia (6 x 19 stranded wire with steel core of 6 mm dia ) sheathed with PVC 2mm wall thickness, overall thickness being 37 10mm PVC sheath should be made of type 6 compound as per IS 5831 of 1984 Reaffirmed 2001 and steel wire rope as per IS:2266:2019. Reclaimed or recycled material should not be used. This will include drilling of 7.1mm dia holes in rails (4 Nos) and provision of two jumpers for each bond, clipping of bonds etc. with contractors own materials and tools as per instruction of Rly engineer at site. (Inspection by Consignee)

200

195

39038

... More
Provision of bonding with GI wire 4mm dia ( 8 SWG) for track jumper & fish plate joints 38 bonds. This will include drilling of 7.1mm dia holes in rails (4 Nos) and provision of two jumpers for each bond, clipping of bonds etc. with contractors own tools as per instruction of Rly engineer at site. (Inspection by Consignee)

200

184

36928

... More
Excavation of cable trench as per cable route plan,1.0 mt. deep and 300mm wide along side the track in normal soil/strata, conforming to distances as per cable route plan and refilling after cable laying. This work includes covering of cable laid in trench by loose soil for a layer of 50mm 39 thickness after clearing of route,bushes etc. It shall be ensured that top of the cables laid is at a depth of 0.8m or more. It if is less, then the width and depth shall be suitably increased and accordingly proportionate payment shall be made. In case depth of trench is not achievable due to site conditions proportionate payment will be made as per procedure. The work shall be done as per the extant practice on Central Railway and instructions of Railway Engineer at site. Drg. No. SK 805 (Inspection by Consignee)

500

367

183535

... More
Excavation of cable trench as per cable route plan,1.0 mt. deep and 300mm wide along side the track in hard soil, conforming to distances as per cable route plan and refilling after cable laying. This work includes covering of cable laid in trench by loose soil for a layer of 50mm 40 thickness after clearing of route,bushes etc. It shall be ensured that top of the cables laid is at a depth of 0.8m or more. If it is less, then the width and depth shall be suitably increased and accordingly proportionate payment shall be made. In case depth of trench is not achievable due to site conditions proportionate payment will be maden as per procedure. The work shall be done as per the extant practice on Central Railway and instructions of Railway Engineer at site. Drg. No. SK 805 (Inspection by Consignee)

450

611

275305.5

... More
Cutting of all types of Roads/ platforms (ecxcept concrete type) for trenching and 41 excavation to depth of 300mmx300mm wide approx. and refilling after laying of RCC/GI /DWC pipe & to restore them to original condition. The work shall be done as per extant practice on C.Rly & instructions of Rly engineer at site. Drg. No. SK 807 (Inspection by Consignee)

18

3058

55061.28

... More
Fixing of GI pipes for crossing the culverts, bridges etc. and concreting of ends with brick masonry at both ends as per the instruction of Rly engineer at site. (Inspection by Consignee)

120

73

8805.6

... More
Digging of trench 1.0 M deep from rail flange/road level (for LC) and 0.3Mtrs. to 0.6 43 Mtrs wide and back filling after placing of DWC/RCC/GI pipe.(Placing of DWC/RCC/GI pipe coverd separately. The ballast disturbed be screened and dressed as required by Engineer-in-charge or his representatives and road tarred immediately. Drg. No. SK 806 (Inspection by Consignee)

30

671

20133.6

... More
Laying of DWC/RCC pipes alongwith collars/RCC Half round pipes in trenches at places of track and road crossings, platform cuttings etc. (Inspection by Consignee)

120

59

7154.4

... More
Laying of signalling/Power/Telecom cable of various cores/sizes in trenches. (Inspection by Consignee)

20

5450

109019.4

... More
Wherever depth of 0.5M cable trench is not feasible, cable shall be protected as under:- Preparation of cement mixture 1:3:6 with contractor's own materials and spreading cement concrete mixture layer of 100 mm thick over the already laid cables in the excavated trench. (Inspection by Consignee)

-

-

46

... More
Fixing of modular terminal/fuse blocks alongwith all accessories with provision of fixing 47 holes on hylam sheets/side angles of Loc Box and fixing by galvanised nuts & bolts. This includes fixing of DIN channel alongwith PVC Comb type 'C' channel (size 2 inch x 2 inch) for cable termination on modular terminal. The PVC channel with cover to be supplied by firm as required. The work shall be done as per the instruction of Rly engineer at site. (Inspection by Consignee)

1500

21

32880

... More
Termination of cable cores on ARA terminal / Disconnecting link/fuse blocks, in the 48 Apparatus cases/cable termination rack. This includes all assosiated works of pulling out the cable from under underground. The work shall be done as per location plans and instructions of Rly engineer at site. (Inspection by Consignee)

3000

8

24510

... More
Laying of GI pipes in on bridges/culverts/concrete drawin/mountain ridges etc. with 49 suitable GI bend shall be provided where there is turning of pipe as per the instruction of Site engineer. GI clamps at every 2m as shown in the drawing to be fixed. Suitable holes to be made in the pipe before laying as per the instruction of the site engineer 10mm dia Drg. No. SK 808. (Inspection by Consignee)

120

129

15493.2

... More
Making an entrance for new cable in old existing location, Casting concreting and curing of foundation and restoring it to old position by perfect masonry/concreting work. Contractor will ensure that cable entered in Location Box is properly protected. (Inspection by Consignee)

15

531

7970.55

... More
Laying of RCC half round cement pipe of appprox. Size (150/300mm dia X 2 mtr. length) inside the trench after laying of cable. Pipes shall be placed as per directives of site engineer. (Inspection by Consignee)

200

41

8214

... More
Painting of two coats of synthetic enamel paint over one coat of primer on the following after scraping & cleaning surface wherever necessary with contractor' own supply of 52 paints.Wherever required contractor shall apply coating of epoxy paint also as per instructions of site- in-charge.Epoxy paint will be supplied by Railways. NOTE:- The paint and primer should be from M/s Asian paints Co. Ltd.,. The paints will be primer (IS 5660 of 1970) the Aluminium synthetic black enamel (IS 2932 of 1974) brilliant white and yellow Painting two coats of enamel paint over one coat of primer. (i)Apparatus Case Full Size. (Inspection by Consignee)

5

456

2283.4

... More
Painting of two coats of synthetic enamel paint over one coat of primer on the following after scraping & cleaning surface wherever necessary with contractor' own supply of 53 paints.Wherever required contractor shall apply coating of epoxy paint also as per instructions of site- in-charge.Epoxy paint will be supplied by Railways. NOTE:- The paint and primer should be from M/s Asian paints Co. Ltd.,. The paints will be primer (IS 5660 of 1970) the Aluminium synthetic black enamel (IS 2932 of 1974) brilliant white and yellow Painting two coats of enamel paint over one coat of primer. (ii) Apparatus case Half Size. (Inspection by Consignee)

2

342

685.88

... More
Painting of two coats of synthetic enamel paint over one coat of primer on the following after scraping & cleaning surface wherever necessary with contractor' own supply of paints.Wherever required contractor shall apply coating of epoxy paint also as per instructions of site- 54 in-charge.Epoxy paint will be supplied by Railways. NOTE:- The paint and primer should be from M/s Asian paints Co. Ltd.,. The paints will be primer (IS 5660 of 1970) the Aluminium synthetic black enamel (IS 2932 of 1974) brilliant white and yellow Painting two coats of enamel paint over one coat of primer. (iii) Shunt signal post with signal unit, surface base as per Central Railway's Standard Practice. (Inspection by Consignee)

5

207

1039.25

... More
Painting of two coats of synthetic enamel paint over one coat of primer on the following after scraping & cleaning surface wherever necessary with contractor' own supply of 55 paints.Wherever required contractor shall apply coating of epoxy paint also as per instructions of site- in-charge.Epoxy paint will be supplied by Railways. NOTE:- The paint and primer should be from M/s Asian paints Co. Ltd.,. The paints will be primer (IS 5660 of 1970) the Aluminium synthetic black enamel (IS 2932 of 1974) brilliant white and yellow Painting two coats of enamel paint over one coat of primer. (iv) Track lead Junction Box. (Black enamel outside only) (Inspection by Consignee)

50

102

5133.5

... More
Lettering / Numbering of Signals, Point Machine, Track Lead Junction Boxes, Block Joints, Apparatus Cases etc. (each item to be taken as One Unit) This work will be carried out as per the standard practice being followed in Central Railway. (Inspection by Consignee)

100

65

6517

... More
Lettering / Numbering Termination particulars, equipments names etc., legibly and neatly inside location boxes. (i) Full Case. (Inspection by Consignee)

5

276

1381.95

... More
Lettering / Numbering Termination particulars, equipments names etc., legibly and neatly inside location boxes. (ii) Half Case. (Inspection by Consignee)

2

157

314.7

... More
Installation, testing & commissioning of the 25 W VHF system including the erection of Mast, Antenna, charging of the battery with all Contractor's materials. (Inspection by Consignee)

2

9924

19849.34

... More
Laying of HDPE duct in trench and its protective work as per direction of site engineer. (Inspection by Consignee)

0.5

-

2732.3

... More
Supply of AC and DC low current clamp meter with range 1mA to 100 A; make GTC CM 100 or similar model from make Fluke, Rishab, Motwane or similar. (Inspection by Consignee)

1

30511

30511.28

... More
Supply of Stencil type LED Route Indicator indicating 1 to 9 nos. (In the event of failure of any of the LED Segment, ECR will drop). (Inspection by Consignee)

1

91299

91299.82

... More
Supply of insulation L bracket for IRS point machine consisting for insulation plate 1 no., ferrules 02 nos, washer 04 nos. material nylon -66 (for safety work). (Inspection by Consignee)

50

388

19445

... More
Supply of Nylon Insulations for TWS Point Machines consist of plate to RDSO Drg.No.S3404 - 02 Nos., Stretcher bar bush RDSO Drg.No.S23199 - 12 Nos., Flat washer RDSO 4 Drg.No.S8640 - 12 Nos. Throw Rod bush RDSO Drg.No.S3436 - 01 No., Flat washer RDSO Drg.No.S8640/2 - 02 Nos. Lock rod bush RDSO Drg.No.S22179 - 02 Nos. Washer RDSO Drg.No.S6840/1 - 04 Nos. Detection rod bush RDSO Drg.No.S23199 - 02 Nos. Flat washer RDSO Drg.No.S6840 - 04 Nos. and MS Flat washers suitable to RDSO No.S8640 - 16 Nos., Suitable to RDSO Drg.No.S8640/1 - 04 Nos., Suitable for RDSO Drg.No.S4680/02 - 04 Nos. (Inspection by Consignee)

200

427

85512

... More
Providing Road Breaker/concreate breaker/ boulder or rock breaker with compressor & 5 Jack Hammer for Railway work such as cutting & dismentalling of road concrete/Brick pucca structure(RCC/Steel section) including contractors fuel, driver and all other charges. (Inspection by Consignee)

100

1707

170796



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.