Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.

Central Railway - CR Tender

Works
Electrical Goods and Equipments
Telecommunication Services
Electrical and Electronics
Ireps
Opening Date30 Jan 2025
Closing Date24 Feb 2025
Tender Amount₹ 16,56,48,262.08 
Notes
Download

Costs

Summary

I) Provision Of Indoor & Outdoor Signaling Work Including Supply Of Materials, Installation, Testing & Commissioning For Electronic Interlocking At Ballarshah

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply of tag blocks 200/160/120 way with polycarbonate cover as per IRS S 77-2006. (Rev.1) RDSO DRG. No.SA 24751, SA 24752 & SA 24753. Requirement of each type shall be specified by Engineer-in-charge. (Insp Agency- RITES)

10

1669

16695.6

... More
Supply of Main cable Termination rack complete with scaffolding, fixtures & 5 accessories including square bars for mounting 8-way terminal blocs, ladder, string rods, frame, base assembly, insulators, J bolt , nut/bolts & fasteners, backelite sheet, etc. Siemens type and as per extant practice of Central Railway. Typical part list as per Annexure-III and rack arrangement shall be as per sketch No.SK-727 with latest alterations. (Insp Agency- RITES)

12

35876

430520.64

... More
Supply of Data logger for monitoring status of important relays, complete with processor Module to monitor following inputs as per spec. RDSO/SPN/99/2006 Spec.No: IRS:S-99/2006 6 (Amdt-3) with latest amlendments including power supply of adequate capacity, battery and fault diagnostic software for failure analysis. Complete data logger & Processor Module (computer) as per Annexure-IV shall be placed in President rack of suitable size to be supplied. This also includes supply of one no composite computer & printer table (work station table-Godrej/Durian/Transteel) for keeping processor module and one no Godrej/Durian/Transteel make operator chair. (Insp Agency- RDSO)

-

-

2964005.25

... More
Supply of PVC Indoor cable 1x60x0.6mm dia colour coding of insulation of inner core shall be in six colour viz Blue, Red, Grey, Brown & Black conforming to IRS 76/89 (Amd.3) or latest. (Insp Agency- RDSO)

4

354797

1419189.84

... More
Supply of PVC Indoor cable 1x40x0.6mm dia colour coding of insulation of inner core shall be in eight colour viz Blue, Red, Grey, Green, Brown, Black, Yellow & White conforming to IRS 76/89 (Amd.3) or latest. (Insp Agency- RDSO)

4

232755

931021.88

... More
Supply of PVC indoor cable 1x24x1 mm dia. Colour coding of insulation of Inner conductor shall be in eight colour viz, Blue, Red, Grey, Green, Brown, Black, Yellow & white confirming to IRS 76/89 (Amd. 3) or latest. (Insp Agency- RDSO)

3

345312

1035937.74

... More
Supply of Indoor Jumper wire of various colour as per Railways standard practice of type ATC 1x0.6 mm dia. Conforming to IRS/76/89 (Amd.3) of latest. (Insp Agency- RDSO)

12

10204

122451.6

... More
Supply of Indoor Jumper wire ATC 1x1 mm dia. Conforming to IRS/76/89 (Amd.3) of latest.

5

15450

77251.9

... More
Supply of PVC flexible copper cable single core, multistrand 1 x 2.5 Sq.mm (50 12 conductor each diameter 0.25 +/- 0.01) as per IS 694/2010. with latest amendment if any with insulation thickness of 0.70mm nominal conductor resistance 7.98 ohms/km and test parameters are as per IRS (S) 76/89 (Amd.3). (Insp Agency- RDSO)

10

52599

525992.7

... More
Supply of PVC flexible copper cable single core, multistrand 1 x 6 Sq.mm (84 conductor 13 each diameter 0.30 +/- 0.01) as per IS 694/2010. with latest amendment if any with insulation thickness of 0.80mm nominal conductor resistance 3.30 ohms/km and test parameters are as per IRS (S) 76/89 (Amd.3). (Insp Agency- RDSO)

12

108108

1297301.16

... More
Supply of PVC flexible copper cable single core, multistrand 1 x 10 Sq.mm (80 14 conductor each diameter 0.40 +/- 0.01) as per IS 694/2010. with latest amendment if any with insulation thickness of 1.0mm nominal conductor resistance 1.91 ohms/km and test parameters are as per IRS (S) 76/89 (Amd.3). (Insp Agency- RDSO)

10

166449

1664499.7

... More
Supply of PVC flexible copper cable single core, multistrand 1x16 Sq.mm (126 15 conductor each diameter 0.40 +/- 0.01) as per IS 2465/1984 & IS: 694/2010. with latest amendment if any with insulation thickness of 1.0mm nominal conductor resistance 1.121 ohms/km and test parameters are as per IRS (S) 76/89 (Amd.3). (Insp Agency- RDSO)

5

247715

1238576.95

... More
Supply of PVC flexible copper cable single core, multistrand 1 x 25 Sq.mm (196 16 conductor each diameter 0.40 +/- 0.01) as per IS 2465/1984 & IS: 694/2010. with latest amendment if any with insulation thickness of 1.2mm nominal conductor resistance 0.780 ohms/km and test parameters are as per IRS (S) 76/89 (Amd.3). (Insp Agency- RDSO)

5

384935

1924677.15

... More
Supply of wire 16/0.2 (blue, red, gray, yellow, brown, black, white as per site engineer instruction) finolex/polycab/delton make. IRS:S-76/89 (Amd.3), BS: 4808 Part-2. Wire to be procured from RDSO approved vender. (Insp Agency- Consignee)

20

7605

152106

... More
Supply of low maintenance Lead Acid secondary cells 2V 80AH as per spec. IRS 88/2004 with latest amendments. (Insp Agency- RDSO)

360

2356

848394

... More
Sealed maintenance free VRLA Battery/Cell 2 volt, 300AH IRS: S-93/96 (A) (Amd.1) or latest. Note: Batteries to be supplied in set of 60 cells (stackable) in combination of 55+5 cells for SMPS based IPS. (Insp Agency- RDSO)

180

5947

1070496

... More
Supply of Automatic changeover for individual supply. Automatic changeover unit of 20 signal / Track / DC circuit supply of 32A, AC/DC consisting of 3TC44 contractors, LED Lamp, Push button, terminals, VSR, polarity switches. As per Rly. Drg.-SK-841/1-5 for IPS supply to manual discrete equipments with P/switch. (Insp Agency- RITES)

60

34670

2080215.6

... More
Supply of 63 A rating, 4 pole change-over switch disconnector with dual shaft position & staggered terminals with sheet steel enclosure and extended handle of Siemens/L & T / HAVELLS/LEGRAND make. (Insp Agency- Consignee)

10

8973

89734.8

... More
"Relay base plate complete with amphanols, code pins, fixing screws etc. suitable for 22 Metal to Metal K-50 mini groups/ECRs of Siemens Make or functional equivalent of other makes. Note : Relay Base plates, are to be procured from Relay manufacturer (OEM). Manufacturer's Certificate for procurement and guarantee in this regard should be furnished. The payment to be released only after Manufacturer's Certificate is submitted.(Insp Agency- Consignee)"

100

861

86122

... More
"Major Relay Group Base Plates, complete with fedlisters (20 No per base plate), guide 23 rails and other accessories suitable for major group of siemens make or functional equivalent of other makes. Note : Relay Base plates, are to be procured from Relay manufacturer (OEM). Manufacturer's Certificate for procurement and guarantee in this regard should be furnished. The payment to be released only after Manufacturer's Certificate is submitted. (Insp Agency- Consignee)"

10

15858

158587

... More
Supply of signal group 2 aspect without base plate siemens make (No.A-RT-RG-A066) or functional equivalent and should be suitable for working with LED based signal lighting unit. (Insp Agency- RDSO)

4

61105

244421.36

... More
Supply of signal group 3 aspect without base plate siemens make (No.A-RT-RG-A067) or functional equivalent and should be suitable for working with LED based signal lighting unit. (Insp Agency- RDSO)

-

-

25

... More
Supply of Shunt signal group siemens make (No.A-RT-RG-A065) or functional equivalent without base plates (suitable for LED signal) (Insp Agency- RDSO)

2

67826

135653.4

... More
Supply of Route Group siemens make (No.RSSK 31/0002) or functional equivalent without base plates. (Insp Agency- RDSO)

2

69649

139299.34

... More
Supply of Point Group RRI, siemens make (No.RSSK 3515/19) or functional equivalent without base plates. (Insp Agency- RDSO)

4

107916

431664.76

... More
Supply of Time Element Relay (Clock work type) AG timer siemens make (No.RSSK 30/0052) or GIC make or functional equivalent. (Insp Agency- Consignee)

15

9196

137947.05

... More
Supply of Key Lock Relay with different ward combinations (Three extra set of ward plate for point Machine to be supplied with each relay). siemens make working on 60V DC/24 DC or functional equivalent without base plates. RDSO/SPN/219/2016 version 1.0 d 1

10

10792

107922

... More
Supply of Plug In type Relay Metal to Metal type neutral relay mini groups ( AC 31 Immunised-1) Siemens make (No.RSSK 30/0078-1) (Ref.IRS:S46/74 with Amd.1 & firms specification). or functional equivalent without base plates. Contact configuration 5F/3B or 6F/2B or 4F/4B to be specified by Engineer incharge. (Insp Agency- RDSO)

50

10250

512525.5

... More
Supply of Plug In type Relay Interlocked Siemens make (No.RSSK 30/0012 ) or functional equivalent (Ref. IRS:S46/74 with Amd.1 & firms specification). Contact configuration 4F/4B.

40

8907

356291.2

... More
Supply of Metal - To - Metal universal LED type ECR Siemens make (type A-RT-RG- A064) or functional equivalent without base plates, should be suitable for working with LED based signal lighting unit. IRS:S:46 & STS/E/RELAYS/AC LIT LED SIGNAL/09-2002 Amd.1 (Insp Agency- RDSO)

10

8169

81692.7

... More
Supply of QNA1 AC immunised relay, 8F-8B, 24 VDC along with plug, board, retaining clip and connectors conforming to BRS:931A, IRS:S60, IRS:S34 & IRS:S23 (Insp Agency- RDSO)

140

4545

636407.8

... More
Supply of QN1 Non AC immunised neutral relay, 8F-8B, 24 VDC along with plug, board, retaining clip and connectors conforming to BRS:930, IRS:S60, IRS:S34 & IRS:S23 (Insp Agency- RDSO)

30

4755

142678.2

... More
Supply of QSPA1 relay, 24 V DC Slow to pick up, 8F- 4B along with plug, board, retaining clip and connectors conforming to BRS:933A, IRS:S60, IRS:S34 & IRS:S23 (Insp Agency- RDSO)

40

5209

208384.8

... More
Supply of QTA2 AC immunised track relay, 9 Ohm, 2F.1B, along with plug, board, retaining clip and connectors conforming to BRS:939A, 966 & Appendix F2, IRS:S34 & IRS:S23 (Insp Agency- RDSO)

140

4554

637642.6

... More
Supply of QBAT track Relay, AC immunised, 2F-2B, contacts, 9 ohms. Complete with plug, board, retaining clip and connectors as per RDSO/SPN/84 Ver 2.0 or latest. (Insp Agency- RDSO)

24

7792

187019.28

... More
Supply of QNA1K relay 1000 ohm, 6F/6B 24V DC as per BRS :931A, IRS:S60, IRSS354 & IRS:S23 and RDSO Spec. STS/E/Relays/UEA (PI) dtd.30.05.1997 Annexure II (Insp Agency- RDSO)

20

4894

97891.4

... More
Supply of Block filter unit as per IRS:S-68/89 and Block bell equipment as per IRS:TC- 44/88 (Amd. 1). (Insp Agency- RDSO)

2

29902

59804.22

... More
Supply of Block Bell equipment as per RDSO Drg. No.TCA 15080 and Specn. No IRS-TC- 44/88 (Amd.1) with amendment No. 1 Voltage 24 V DC. (Insp Agency- RDSO)

2

4340

8680.24

... More
Supply of Domino units with cover plate as per approved panel diagram, each of size 42 54 x 34mm completely wired up similar to siemens make. Each domino units should have all the 15 contact terminals wired up. (Insp Agency-Consignee)

150

1911

286659

... More
Panel Indication bulbs (Double LED type) working voltage 24V - Colour - Red/Yellow/Green. (Insp Agency-Consignee) 44

100

52

5272

... More
Supply of INDICATIVE TYPE OF FUSE INSERTS. IRS S:-78-92 (Insp Agency-Consignee)

-

-

123607

... More
Supply of PPTC Fuse GP 60-185 UL-94 certification (1.6 Amps) for internal / external current. Make: LITTLEFUSE, FUZETEC, TYCO, BOURN, RAYCHEM etc. (Insp Agency-Consignee)

150

11

1795.5

... More
Supply of PPTC Fuse GP 60-400 UL-94 certification (12V/4A) TF, TR Circuit. Make: LITTLEFUSE, FUZETEC, TYCO, BOURN, RAYCHEM etc. (Insp Agency-Consignee)

150

10

1515

... More
Supply of PPTC Fuse GP 30-100 (12V/1.4A) TPR Circuit. Make: LITTLEFUSE, FUZETEC, TYCO, BOURN, RAYCHEM etc. (Insp Agency-Consignee)

150

10

1515

... More
Supply of PPTC Fuse GP 250-185 UL-94 certification (24V/4A)110V AC for track chargers. Make: LITTLEFUSE, FUZETEC, TYCO, BOURN, RAYCHEM etc. (Insp Agency-Consignee)

150

10

1515

... More
Resin cored wire as per specification No.IS:1921-1975 with Alloying element percentage as 63% SN (Tin) and / 37% pb (Lead) with percentage of various impurities not exceeding 49 the values Sb (Antimony 0.2% maximum, Cu (Copper) 0.1% maximum, As (Arsenic) 0.05% maximum, Fe (Iron) 0.02% maximum & other impurities mainly AI, Zn & Cd shall be limited. The flux shall be free from corrosive action as per clause 5.2 & flux percentage may be used as per requirement. (Insp Agency-Consignee) 50

100

1478

147804

... More
Lacing thread rolls, black, wax coated (100 mtrs) (Insp Agency-Consignee)

50

78

3903

... More
Design, fabrication and supply of fuse Auto changeover system for 32 No's external 51 non detorating type fuses or 'G' type fuses from 0.6A Amp to 4A Amp capacities used in signaling circuits. System shall have 8 cards with monitoring arrangement of 4 fuses in one card. As per RDSO sepc. RDSO/SPN/209/2012 Ver.2.0 or latest amendment if any. (Insp Agency-RDSO)

44

31577

1389391.08

... More
Design, fabrication and supply of fuse Auto changeover system for 24 No's external 52 non detorating type fuses or 'G' type fuses from 4 A to 10 Amp capacities generally used for point operation circuits. System shall have 6 cards with monitoring arrangement of 4 fuses in one card. As per RDSO sepc. RDSO/SPN/209/2012 Ver.2.0 or latest amendment if any. (Insp Agency-RDSO) (Note: Unit to be treated as Number of Modules)

12

47805

573669.48

... More
Supply of Shunt signal post with Base (GI Pipe of 80 mm Dia of min. 1 meter length.) (Insp Agency-Consignee)

24

3199

76799.52

... More
Supply of Cast Iron Main signal surface base 140mm as per spec No IRS: S-10 and Drg 54 No 2011/M with latest amendments, with CLS Ladder assembly complete for CLS signal 5.5/4.5/3.5 mtrs long as per Rno. SA 23156 (Adv), SA 23153 (Adv) & SA 23150 (Adv) Alt.1 respectively with Latest Amendment as the case may be for CLS unit & signal back staging as per extent C.Rly practice. (Insp Agency-Consignee)

14

10660

149243.64

... More
Supply of Cast Iron Shunt signal surface base 80 mm as per spec No IRS: S-10 and Drg No 2011/M with latest amendments, as per RDSO Drg. No.SA- 23156/ Drg. No.RST/11413 as per extent C. Rly practice. (Insp Agency-Consignee) 56

24

2444

58674.48

... More
Supply of Signal No. Plates. As per Drg No RST-11393/ SK-842 (Insp Agency-Consignee)

120

615

73870.8

... More
OFF set bracket 5-1/2" to suit 140 mm dia CLS Post with two no. of "U" Bolts with nut & washer complete as per RDSO Drg No SA-23080 for signals & Routes. (Insp Agency-Consignee)

8

1179

9437.52

... More
Supply of A/AG/C/P/G/IB Board as per Drg. RST-11444/1(A), RDSO Drg No SA- 23460(AG), SA-23461(C) , RST-11445, SA 23456(P), SA 232477(G) & SA 23476-77 (IB) as applicable respectively with Latest Amendment. (Insp Agency-Consignee)

12

662

7954.2

... More
Supply of Stop Board / IB Board as per RST-11791 (STOP BOARD)/ RDSO Drg No 7235/B as per extent C.Rly practice. (Insp Agency-Consignee)

6

3941

23647.98

... More
Supply of Hand Cuff Locks / Godrej Navtal lock with Three common keys. (Insp Agency- Consignee)

250

337

84430

... More
Supply of "2 aspect" Signal Unit in FRP body without lenses and transformers as per 61 RDSO Specification RDSO/SPN/194/2006/Rev.2.0 or latest complete and to suit LED signal Lamps and suitable for 140 mm dia post saves pigment finish on the back side of the and inside. white pigment finish inside the 2 aspect unit to avoid any extra paint cost. (Insp Agency-RITES)

30

36508

1095255

... More
Supply of "3 aspect" Signal Unit in FRP body without lenses and transformers as per 62 RDSO Specification RDSO/SPN/194/2006/Rev.2.0 or latest complete and to suit LED signal Lamps and suitable for 140 mm dia post saves pigment finish on the back side of the and inside. white pigment finish inside the 4 aspect unit to avoid any extra paint cost. (Insp Agency-RITES)

20

37416

748332.2

... More
Supply of "4 aspect" Signal Unit in FRP body without lenses and transformers as per 63 RDSO Specification RDSO/SPN/194/2006/Rev.2.0 or latest complete and to suit LED signal Lamps and suitable for 140 mm dia post saves pigment finish on the back side of the and inside. white pigment finish inside the 4 aspect unit to avoid any extra paint cost. (Insp Agency-RITES)

4

48408

193635.92

... More
Supply of Shunt Signal Position Light Type FRP complete as per RDSO Specification 64 RDSO/SPN/194/2006/Rev.2.0 or latest with Off set bracket 3-1/2" to be fitted on 140 mm post drawingNo.SA23840(Adv) Alt-2 for dependent type complete with signal unit bracket, terminals etc without lenses, lamp, lamp holder, and to suit LED signal lamps.(Inspection Agency - Consignee)

24

16461

395071.68

... More
Supply of 2 way junction Route Indicator in FRP body without lenses and transformers as per RDSO Specification RDSO/SPN/194/2006/Rev. 2.0 or latest complete and to suit LED signal Lamps (Insp Agency-RITES)

12

52429

629157.12

... More
Supply of 3 way junction Route Indicator in FRP body without lenses and transformers as per RDSO Specification RDSO/SPN/194/2006/Rev. 2.0 or latest complete and to suit LED signal Lamps (Insp Agency-RITES)

4

53329

213318.6

... More
Supply of 4/5 way junction Route Indicator in FRP body without lenses and transformers as per RDSO Specification RDSO/SPN/194/2006/Rev. 2.0 or latest complete and to suit LED signal Lamps (Insp Agency-RITES)

4

58706

234826

... More
Supply of "Calling On" Signal Unit in FRP body without lenses and transformers as per RDSO Specification RDSO/SPN/194/2006/Rev. 2.0 or latest complete and to suit LED signal Lamps . (Insp Agency- Consignee)

6

10230

61381.86

... More
Supply and Fixing of RE Protective Screens of expanded metal 12 SWG of size 1200 x 1500 mm on signals as per extent practice & as per instruction of Rly engineer at site DRG - No.SK- 844. (Insp Agency- Consignee)

10

6168

61681.6

... More
Supply of Phenolic 10mm thick sheet, grade P3 in standard size of 1.22x1.22 Mtr as per spec. No. IS 2036 of 1995. (Insp Agency- RITES)

200

6195

1239114

... More
Supply of ARA Terminal blocks wih links made of PBT Specn No.IRS/75/2006 (Rev - 2) with latest amendments and RDSO Drg.No.SA-23741A Alt.4., SA-23745 Alt.5, SA-23746, SA-23748 Alt.4, & SA-23756 Alt.3. (Insp Agency- RDSO)

24000

85

2056320

... More
Supply of cartridge fuse block made of PBT as per RDSO Drg No SA-23748 Alt 4, SA- 23749 & Spec No.IRS S 75/2006 with latest amendment. Fuse block shall be suitable for found head type voltage fuses. (Insp Agency- RDSO)

240

192

46144.8

... More
Supply of round head type non detorating type low voltage cartridge fuse as per specn No. IRS/S/78/92 with latest amendments - 2A/4A/6A capacity (Insp Agency- RDSO)

240

82

19860

... More
Supply of Tik-tak, piano type switches, 5 A (as per IS Specification). (Insp Agency- Consignee)

240

39

9460.8

... More
Supply of three pole plug and socket 5 Amp (as per IS Specification). (Insp Agency- Consignee) 76

-

-

75

... More
Supply of Lamp 110V / 24W, 2 pin for Loc. (Insp Agency- Consignee)

240

26

6436.8

... More
Supply of Apparatus case with godown locks with detachable handle on both the doors. (Insp Agency- RITES)

-

-

4312717.8

... More
Supply of earth electrode assembly as per Drg.No.CR/S&T/SK-815 (Insp Agency- Consignee)

250

1272

318032.5

... More
Maintenance Free Earth as per RDSO/SPN/197/2008 or latest consisting of : 1) Copper 79 bond steel electrode 3 Mtr long 17mm dia with copper bonding thickness of min. 250micron & UL listed & marked-01 No. (2) Earth enhancement compound RDSO Approved in sealed bag of 10 kgs - 03 No. (3) Copper strip 150 x 25 x 6mm - 02 No (4) Copper Strip 300 x 25 x 6mm- 01 No (5) 35 Sqmm Copper Cable to connect earth electrode to MEEB - 15Mtr Approx. (Insp Agency- RDSO)

34

20987

713587.58

... More
Supply of Microprocessor based universal earth resistance sensing unit 12 channel AC/DC. As per RDSO/SPN/256/2002 with latest amendments. (Insp Agency- RDSO)

3

171839

515517.99

... More
Supply of Track Lead junction Boxes as per C.Rly Drg.No. RST 11509 made from fiber glass along with terminal blocks.(Insp Agency- RITES)

400

1236

494648

... More
Supply of B type choke to specn.No.IRS.S.65/83 (Amd.3 ) with latest amendments.(Insp Agency- RDSO)

160

4326

692206.4

... More
Supply of adjustable Track Feed Resistance disc type 7.5/15/30 ohms as per RDSO Drg. No. SA 20161-66/M (Adv) with latest amendments ( with phenolic moulded base). (Insp Agency- RDSO)

160

1520

243201.6

... More
Supply of Track feed battery chargers, 110V AC input 2, 4 to 6 V DC Output to Specn. No.IRS.89/2013 Ver.1.0 with latest amendments. Charger shall be suitable for charging 80 AH battery. (Insp Agency- RDSO)

160

2867

458840

... More
Supply of Channel Pins single groove, galvanised, 7 mm suitable for 4mm dia bonding wire as per spec No. IRS: S 17-75 Revision 3.(Insp Agency- Consignee)

12000

2

28440

... More
Supply of PVC jacketed wire rope for track lead connections. PVC jacketed wire rope 86 should be of Galvanised steel wire rope 6mm dia (6x19 stranded wire with steel core of 6 mm dia) sheathed with PVC 2mm wall thickness, overall thickness being 10 mm. PVC sheath should be made of type 6 compound as per IS 5831 of 1984 Reaffirmed 2001 and steel wire rope as per IS: 2266:2019. Reclaimed for recycled material should not be used. (Insp Agency- Consignee)

12000

61

740400

... More
Supply of 8 SWG GI wire (4mm dia) suitable for track circuit rail bonding. As per IRS Specification S:13@45>46@ (Insp Agency- Consignee)

1000

102

102450

... More
Supply, Installation, testing and commissioning of track battery charger monitoring system for 2V/4V/6V/8V batteries with accessories at nominated stations. General scheme to be approved by Engineer-in-charge.(Insp Agency- Consignee) Per

160

1967

314731.2

... More
Supply of Digital Axle counter Multi section type complete system including the central Evaluator and final track clearance relay for each section, Reset boxes, LV boxes, All track side units with detection point complete assembly & fixing arrangement foreach detection point, clamps deflector for either side of each detection points, monitoring console for monitoring all the DPs at a time installed at a station/RH/IBH etc. with all other accessories fully wired and fully equipped as per RDSO specification No. RDSO/SPN/176/2013 (ver.3) or latest and manufacturers specification. The equipment must also include the following: a) System must have remote monitoring and health diagnostics feature as per RDSO specification. b) Surge protection device, c)20% spare slots for the both detection heads and track section in the evaluator for future and emergency provision. Each set also consisting of a)Double rail contact of standard length of cable as per site requirement and mounting accessories - Equal to no. of DP. b) Deflectors to safe guard Rail contact will be TWICE the no. of DPs. c) Protecting tube from DP to railhead as per requirement. d) Diagnostic PC asper specification and other accessories (as per Annexure-VI) e) Pre-wired cabinet/rack - No. as per site requirement. f) 6 nos. Electrostatic Discharge Wrist Band for cards/modules protection. (Insp Agency- RDSO)

-

-

89

... More
Supply of William stretcher nylon insulation set suitable for ground connection as per RDSO drg No T-10367, T-10368, T-10384 as applicable and to the spec IRS S 23 & 40/84 with latest amendments. (Insp Agency- Consignee)

2

627

1255.22

... More
Supply of Tongue attachment nylon insulation set consisting of one insulating plate as per Drg no: RST-106961 & 3 nos of Ferrules with collars to suite rodding supplied as per RDSO spec & Drg.no: RST-10692 (Insp Agency- Consignee)

2

399

798.38

... More
Supply Gauge Tie Plate nylon insulation as per RDSO drg No: T-10372Alt2, T-10368, T- 10371Alt2, T-15083/88/Alt2 & T-11690/Alt2 and to the spec IRS S 23 & 40 with amendment 01 or latest amendments. (Insp Agency- Consignee)

2

288

576.1

... More
Supply of GI bend pipe, B class, 50mm dia for cable entry in point machine along with required fixing arrangements as per standard practice on Central Railway. As per Drg No. RST.11835. (Insp Agency- Consignee)

40

298

11931.2

... More
Supply of GI pipe, inner dia. 100mm dia. B-class as per spec. No.IS 1239 PT. 1/2004 or latest with sockets and fittings. TATA/JINDAL/ZENITH BIRLA make. (Insp Agency- RITES)

300

1214

364380

... More
Supply of DWC HDPE pipe with one snap fit coupler and 'O' ring fire resistant, anti rodent, in 6 meter length of size 120 mm outer dia as per RDSO/SPN/204/2011 Ver 1.1 with Amd.1 or latest. (Insp Agency- RITES)

1500

379

568935

... More
Supply of RCC Trunking with capping. Size 250mm x 200mm Drg. No. RST/C/291/A (Insp. Agency- RITES)

4000

1030

4123960

... More
Supply of RCC pipes half round of size 300 mm dia outer and 250 mm dia internal 1 mtr long matching to IS No.458/2003 amendment-1 with Rev.4. (Insp. Agency- RITES)

3000

498

1494780

... More
Supply of modular terminal block of 2.5 sq. mm 2 IN 2 OUT type disconnect type 98 terminal along with as per RDSO SPN/189/2004 Rev 3.0. The current capacity of 16 Amps and more. The terminal should have marking at center to view description from front. Material to be procured from RDSO approved firms only. (Insp. Agency- RDSO) 99

6000

138

829200

... More
Supply of DIN Channel for the terminals 1 Mtrs each (Insp. Agency- Consignee) 100

60

255

15344.4

... More
Supply of End plates for modular terminal block (Insp. Agency- Consignee) 101

1000

27

27600

... More
Supply of End Clamp for modular terminal block (Insp. Agency- Consignee)

1000

19

19840

... More
Electronic LC gate telephone system as per Specification RDSO/SPN/TC-51/2011 Revision -3.0 ( With Voice logging facility) (Insp. agency- Consignee)

-

-

476664.3

... More
Supply of VHF 25W trans receiver (synthesized) set complete consisting of Analog set as per CR specification. (Insp. agency- Consignee)

2

28084

56169.4

... More
Supply, Installation, Testing & Commissioning of Microprocessor based intelligent, addressable, Fire Alarm control Panel with LCD display complying to RDSO/SPN/217/2021 Ver 3 or latest modular, 1 loop (minimum 125 detector/devices per loop-expandable to 2 loops) with 320 104 Character with soft keys for displaying alarm, events and operating functions, Day/Night operationfunction, Remote maintenance service feature etc. The panel should be multi-protocol i.e. able to support at least 2 different makes of addressable detectors. The panel should have minimum two relay outputs & 1 Monitored Sounder Output. It should have provision to be connected to repeater panels in future. The panel shall capable to operate on 230 volts AC power supply, automatic battery charger, 24 volts, sealed lead acid maintenance free batteries sufficient for 24 hours normal working and then be capable of operating the system for 30 minutes during emergency condition. Panel should be Vds Certified. (Insp. agency- RDSO)

1

79317

79317.61

... More
Supply, Installation, Testing & Commissioning of Analogue Addressable Multi sensor Detector complying to RDSO/SPN/217/2021 Ver 3 or latest As per latest VDS approved/Listed. (Insp. agency- RDSO)

80

4008

320676

... More
Supply, Installation, Testing & Commissioning of Manual call points, complying to RDSO/SPN/217/2021 Ver 3 or latest As per latest VDS approved/Listed. (Insp. agency- RDSO)

6

6167

37004.28

... More
Supply, Installation, Testing & Commissioning of Resettable, Analogue Type Liner Heat Sensing (LHS) Cable complying to RDSO/SPN/217/2021 Ver 3 or latest As per latest UL or FM of LPCB approved/Listed. (Insp. agency- RDSO)

250

1668

417167.5

... More
Supply, Installation, Testing & Commissioning of LHS Interface Module with all accessories for single stretch, complying to RDSO/SPN/217/2021 Ver 3 or latest As per latest UL or FM of VDS of LPCB approved/Listed. (Insp. agency- RDSO)

1

158337

158337.29

... More
Supply, Installation, Testing & Commissioning of Aspiration (Air Sampling Type) Detection unit complying to RDSO/SPN/217/2021 Ver 3 or latest As per latest UL or FM of VDS of LPCB approved/Listed. (Insp. agency- RDSO)

1

328465

328465.24

... More
Supply, Installation, Testing & Commissioning of CPVC pipe for Aspiration Detection system complying to RDSO/SPN/217/2021 Ver 3 or latest. And shall be listed/approved by UL or FM or VDS or LPCB or tested with appropriate equivalent standard. (Insp. agency-Consignee)

200

1905

381072

... More
Supply, Installation, Testing & Commissioning of Analogue Addressable loop powered Monitor Module with inbuilt isolator complying to RDSO/SPN/217/2021 Ver 3 or latest. (Insp. agency- RDSO)

4

10320

41280.68

... More
Supply, Installation, Testing & Commissioning of Analogue Addressable loop powered Control Module complying to RDSO/SPN/217/2021 Ver 3 or latest. (Insp. agency- RDSO)

3

10320

30960.51

... More
Su p p ly , Testing & Commissioning of Hooter cum strobe complying to RDSO/SPN/217/2021 Ver 3 or latest. (Insp. agency- RDSO)

3

9143

27429.12

... More
Supply, Testing & Commissioning of 2C 1.5 sq mm twisted shielded armoured copper cable (Per Meter) with accessories complying to the RDSO/SPN/217/2021 Ver 3 or latest. (Insp. agency- Consignee)

500

133

66900

... More
Supply, Testing & Commissioning of Isolator Device to isolate the circuit in case of short circuit, complying to the RDSO/SPN/217/2021 Ver 3 or latest. (Insp. agency- RDSO)

1

4391

4391.24

... More
Supply of 24 fibre straight Joint closure (SJC) complete with all accessories as per RDSO 116 Spec. No. RDSO/SPN/TC/68/2007, Rev.0 Amendment No.1.1 or latest amendments and as per or TEC Spec. G/OJC/02/02 Sept 2003 or latest of Raychem make model FOSC 400 B4 24F or TVS ICS make model 1500-L1 83-XX or Birla VXL make model VT-200 or 3M make model 2179 CD. (Insp. agency- Consignee)

30

4032

120963.6

... More
Installation, testing & commissioning of EI system complying to RDSO Technical Advisory Note No STS/E/TAN/3012 Ver 2.0 dated 10.08.2016 and supply, Installation, testing & 1 commissioning of earthing arrangement for EI as per RDSO/SPN/197/2008 For yard with "TWO OC". With A protection at two locations/Gumtis/Cabins/EI Huts/Auto Hut of the yard, Earthing of EI equipment, relay racks and power equipment etc to be done with Class A protection, Earthing shall be in the form of perimetric/Ring Earth conforming to RDSO specification and RDSO technical advisory note for earthing and bonding scheme of EI No. STS/E/TAN/3006 Ver.1 Dt. 02.11.2012 or latest, with earth resistance less than 1 ohm.

1

1709901

1709901.07

... More
Training of Technician / Engineers/ Senior Engineer in installation, for trouble shooting & repairing, commissioning, Testing, Repairs Troubleshooting. (Hard copies of training material/ course modules to be given to each participant).

1

105508

105508.89

... More
Installation of Relay Rack Assembly including TDF pillars if any complete with wall 3 supports, scaffolding, ladders, runway for cables, Relay/Relay group base plates, fixing of Tag blocks etc. The work shall be done as per approved plan, extant practice on C. Railways & the instructions of Rly engineer at site.

4

1810

7243.92

... More
Installation of Cable Termination Rack Assembly complete including wall supports, 4 scaffolding, Disconnecting links/ARA terminal, 96 way tag block with tag block cover & other necessary accessories etc. The work shall be done as per approved plan, extant practice on C. Railways & the instructions of Rly engineer at site.

12

1541

18501.84

... More
Termination of cable cores on ARA terminal/disconnecting links in the cable termination 5 rack. This includes all associated works of pulling out the cable from under ground, peeling off insulation, dressing of Cable core supported on sting rods with contractors own material. The work shall be done as per instructions of Rly engineer at site.

8064

13

108702.72

... More
Installation, wiring, testing and commissioning of Data logger complete along with 6 accessories with contractors own wiring & fixing material as per following configuration. (It includes loading of NETWORKING software and networking of data logger. The requisite communication cable/channel for networking will be arranged by Railway.

-

-

109650.68

... More
Charging of 2V Lead Acid Batteries with contractors own battery grade sulphuric acid 7 and distilled water with minimum two charge - discharge cycles, installation of charged batteries in groups & their connection & wiring. The work shall be done as per extant practice of C.Rly & instruction of Engineer-in-charge. Detailed measurements of initial charging shall be recorded jointly by contractor & Rly's site-in-charge. (Note :Unit to be treated as Per 100 VAH)

300

89

26859

... More
Fixing of Q series relay base plate/metal to metal relay mini group and major group base plate, laying, bunching, lacing, dressing & packeting of 60/40 core cable/flexible wire on tag 8 block/base plate & base plates & soldering. This includes fuse wiring, bus bar looping etc. required for keeping installation ready for circuit wiring work & panel throughing work. The work shall be done as per approved plan, extant practice on C.Rly & the instruction of Rly. Engineer at site. (Note :Unit to be treated as Tag Block)

10

738

7387.9

... More
Circuit wiring/jumpering as per circuit diagrams in the relay racks/IDF rack tag blocks. This includes preparation of jumper sheets by wire man duly checked by firm's site supervisor & wire 9 to wire testing as per circuit diagram. Any wrong jumper done by wireman will not be paid & correction shall be done free of cost. Jumper wires will be issued by Railways. Good quality solder rosin core to be supplied by contractor for soldering of jumper wires. Soldering of jumper wires to be done after completion of testing by Railways. (Note : Unit to be treated as Jumper)

3000

14

43080

... More
Plugging of relays, provision for temporary relays for NI working if any, laying of temporary cables for mock panel and wiring of Mock panel. Panel through testing of PI/RRI as per 10 selection table, control table etc. This also includes alteration if any in panel wiring, laying & termination of indoor cables from panel to IDF/CT rack of relay room. Contractor shall depute supervisor & wiremen technically qualified to carryout panel through testing as per approved design. Technical knowledge of contractor's staff will be judged by Railways Engineer in-charge before permitting them to do the testing. (Note: Unit to be treated as Route)

100

431

43175

... More
Relay Contact break test of indoor relay wiring. Contractor shall depute Engineer, 11 Supervisor & wiremen technically qualified to carryout contact break testing as per approved circuitdiagrams. Firm Engineer to sign circuit diagrams for break testing after carrying out the test in presence of Railway's site supervisor/Engineer. (Note : Unit to be treated as A3 Size circuit Per Sheet)

150

387

58114.5

... More
Installation and wiring of block instrument. The work of wiring from Telecom DP to 13 block Instrument and block instrument to Relay Room and connection with power supply will be done by the contractor with contractor's own wiring & protection material as per instructions of Engineer-in- charge.

2

11196

22393.48

... More
Installation, testing and commissioning of Automatic Media Changeover of modems working on redundant channels for data transmission on OFC / Quad (Unit - one pair Qty 1 set)

1

31567

31567.4

... More
Installation & commissioning Block proving with Digital Axle counter as per RDSO specification no. IRS:S-105/2012 using UFSBI & Block panel for single/ Double Line operation. (Unit - one pair Qty is 1 set)

1

85897

85897.68

... More
Installation of control and other communication equipment like control phone/magneto phones/auto phones etc in panel Room as per instructions of engineer-in-charge.

2

13013

26027.48

... More
Installation, wiring & Testing of Control cum Indication panel, & test board etc as applicable / as per instructions of Engineer-in-charge. This includes laying & termination of cable, if any from panel Room to Relay Room as per instruction of site in-charge.

1

19397

19397.16

... More
Wiring and Charging of Integrated power supply to signaling installation. This includes connection of MF Earth of 1 ohm earth resistance for IPS and power distribution connection to bus bars and relay racks in the room with contractor's own wiring materials and fabrication and fixing of AC/DC 18 power distribution board made on 10mm thick phenolic hylam sheets or any standard make with connections suitable for 63 A. Wiring to be done considering site requirement, depending upon the load with suitable wires, lugs & glands as per instructions of Engineer-in-charge. This item also includes supply & fixing of ladder along the wall for carrying power supply wires/cables from IPS room to Relay room/power room and potential free contact wiring at Datalogger IDF etc.

3

36788

110365.8

... More
Wiring, fixing & commissioning of modules of fuse 0.6 to 4 Amp rating alarm system 19 having change over arrangement and potential free contact wiring at Datalogger IDF. Etc as per instructions of Railway Engineer. (Module of 32 nos fuses) (Note: Unit to be treated as Number of Modules)

44

763

33585.64

... More
Wiring, fixing & commissioning of modules of fuse 4 to 10 Amp rating alarm system 20 having change over arrangement and potential free contact wiring at Datalogger IDF. Etc as per instructions of Railway Engineer. (Module of 24 nos fuses) (Note : Unit to be treated as Number of Modules)

12

762

9144.96

... More
Lettering & Numbering of detail and description writing of particulars of terminations & 21 equipment on relay rack, relays, cable termination rack, battery & power equipment, IPS, operating panel, axle counter etc constituting entire system with contractor's own paint and writing material ("Asian/Dulux" make enamel paints to be used). The work shall be done as per extant practice on C.Rly & instruction of Rly engineer at site. (Note: Unit to be treated as Per Rack)

16

434

6956.64

... More
Preparation of cable route plan, cable coreage plan, location particulars, cable termination rack particulars, cable meggering report, earth resistance particulars, Traction bonding diagram, 1/2 wire count sheet and any other drawing in Autocad in A3/A4 size. The contractor shall initially supply 3 sets of circuits complete for approval of Railways. Railways will return one set to the 22 contractor duly approved with alteration/corrections if any. The contractor shall incorporate Railways alterations/corrections in the tracings without any deviation and submit all tracings complete in all respects to the Railways. This includes submission of final cable route plan as per laid cable duly measured at every 30m clearly indicating distance of laid cable from fixed point of reference & indicating all track crossings and tail cables. This also include designing of cable coreage plan based upon I.P. in consultation with engineer-in-charge.

-

-

155089.84

... More
Excavation and Casting of main signal foundation as per Drg No SK 801 with 23 contractor's own materials including cement and anchor bolts of standard size. The required scaffolding Ferma etc for casting of foundation will have to be brought by the contractor at his own cost.

50

10796

539811

... More
Excavation and Casting of Shunt signal foundation as per Drg No SK 802 with 24 contractor's own materials including cement and anchor bolts of standard size. The required scaffolding Ferma etc for casting of foundation will have to be brought by the contractor at his own cost.

24

3126

75025.92

... More
Erection of CLS post with surface base and signal unit on top or on OFF set Bracket, 25 fixing of front and back staging, ladder and guards, signal name plates/boards if any with contractors own brackets and fixing materials. This also includes erection of auxiliary signals like calling on, shunt signal if any. The work shall be done as per instructions of Rly engineer at site.

50

4118

205923

... More
Erection of shunt signal with surface base, post, signal unit and fixing of No. plates. The work shall be done as per instructions of Rly engineer at site. 27

24

568

13634.4

... More
Fixing of Jn. Route Indication 1-way/2-way/3-way on the top of the signal post.

20

901

18023.4

... More
Fixing of stop Board, Block section limit Board, goods warning board with contractors own material. The work shall be done as per instruction of Rly engineer at site.

18

652

11751.66

... More
Termination of tail cable on Main signal units and wiring with contractor own material etc. The work shall be done as per instruction of Rly engineer at site.

50

1293

64680

... More
Termination of tail cable on Shunt signal units and wiring with contractor own material etc. The work shall be done as per instruction of Rly engineer at site.

24

420

10088.4

... More
Installation on ON/OFF aspect LED's in signal including termination of tail cable on signal, wiring fixing of LED units and testing. The work shall be done as per instruction of Railway engineer at site.

420

643

270421.2

... More
Fabrication and fixing of phenolic laminated/Fibre glass sheet in location box by 32 providing all fixtures as per Railway Drawing including fixing of PVC coated/with PVC pipe covered string rods at the back side for cable support with contractor's own materials. The work shall be done as per drg and arrangement similar to SK 783- 1& 2. with latest alterations & as per instructions of Rly engineer at site.

-

-

618789.6

... More
Fixing of cutting in relay bases & wiring of relays with Contractors own material obtained from approved sources in location box as per the instructions of Engineer in charge.

420

668

280627.2

... More
Fixing of ARA Terminals and fuse blocks on phenolic laminated sheets and fixing by stainless steel/brass nuts & bolts. This includes provision of two additional holes on the board on either side for cable conductor entry.

24000

397920

397920

... More
Termination of cable cores on ARA terminal/fuse blocks in the apparatus cases/ cable termination rack. This includes all associated works of pulling out the cable from underground. The work shall be done as per location plans and instructions of Rly engineer at site.

24000

299520

299520

... More
Excavation and Casting of Apparatus case foundation with contractors Anchor bolts, cement, ballast and other materials. The required scaffolding ferma etc for Casting of foundation will have to be brought by the contractor at his own cost. 37

-

-

2786332.8

... More
Erection of Apparatus cases. This includes filling of location foundations and plastering.

-

-

292866

... More
Installation of Eqpt. (Relays, resistance, chargersbatteries etc. as applicable) & wiring of the same inapparatus cases as per location diagrams & circuitdiagrams, as per Instruction of site incharge andpractice.

-

-

390174.6

... More
Installation of earth electrode assembly as perDrg.No.RE/S&T/SIG/Tender/SK726/85 including earth wire connected through GI wire 8 SWG supported on M.S. flat of size 6mm x 40 mm to earth electrode as per drg. No.CR/S&T/SK-815 for sigg. Equipment such as lever frames, apparatus case, signals, relay racks, block instruments, and etc. as per RE manual. The earth value should be less than 10 Ohms including the lead wire. The value should be measured in presence of Rly. supervisor. It should be documented and painted on earth enclosure made of concrete.( only earth electrode will be supplied by Railway). All other material required for provision of earthing will be brought by the contractor.

250

2983

745802.5

... More
Installation of unit earth as per RDSO/SPN/197/ver I or latest, to construct earthing of

34

6242

212248.4

... More
Installation, wiring, testing and commissioning of Microprocessor based universal earth leakage detector unit 12 channel AC/DC.

3

8745

26235.06

... More
Erection, Fitting and Rail connection of Track Lead junction Box on two supports (M. S. 42 angle) with contractor's fixing material and PVC jacketed wire for track lead connection including angles of size 40x40x5mm 1200mm length. This will include drilling of holes for track led/side connections of rail. The work shall be carried out as per Drg. No.SK-845 or / & instructions of Rly engineer at site.

400

1540

616120

... More
Provision of bonding with contractor's PVC jacketed wire rope for Track Lead connections. PVC jacketed wire rope should be of Galvanised steel wire rope 6 mm dia (6x19 stranded 43 wire with steel core of 6mm dia) sheathed with PVC 2mm wall thickness, overall thickness being 10 mm. PVC sheath should be made of type 6 compound as per IS 5831 of 1984 Reaffirmed 2001 and steel wire rope as Per IS:2266:2019. Reclaimed or recycled material should not be used. This will include drilling of 7.1mm dia holes in rails (4 Nos) and provision of two jumpers for each bond, clipping of bonds etc. with contractors own materials and tools as per instruction of Rly engineer at site.

12000

200

2402280

... More
Provision of bonding with GI wire 4mm dia (8 SWG) for track jumper & fish plate joints bonds. This will include drilling of 7.1mm dia holes in rails (4 Nos) and provision of two jumpers for each bond, clipping of bonds etc. with contractors own tools as per instruction of Rly engineer at site.

1000

189

189370

... More
Installation of Axle counter (Digital)/Central Evaluator, wiring from CT rack to central evaluator, installation and wiring of indoor & outdoor reset box and wiring the power supply including 45 supply of 2 core shielded cable of required size copper conductor as per IRS S 76/89 or IS694/1977 as applicable with other accessories. NOTE: Installation/programming/configuration/commissioning of Axle counter equipment to be carried out in accordance with latest guidelines issued by Railway/RDSO preferably by Authorized representative of OEM.

4

32261

129045.4

... More
Installation of EJB and Track devices of Digital Axle counter including digging of trench, drilling of holes, if required on rail, lying of Doubled walled anti-rodent corrugated pipe, Medium class 46 from track device to location box and making its terminations. (DWC pipe made up of High density polyethylene of 60mm outer dia of suitable length and all other accessories as per site requirement to be supplied by firm.) NOTE: Installation/programming/configuration/commissioning of Axle counter equipment to be carried out in accordance with latest guidelines issued by Railway/RDSO preferably by Authorized representative of OEM.

4

18563

74253.2

... More
Fixing of track devices (Transmitter coil and receiver coil) to the rails, fixing of EJB in 47 the location connection of track device to EJB using DWC pipe of suitable length and wiring of EJB, testing and adjustment of transmitter and receiver to obtained required channel level as per standard practices on C.rly and instruction of Rly Engineer on site. Per

4

15854

63418.08

... More
Installation, wiring & /commissioning of Multi section Digital Axle counters's central unit/Evaluator/Processor for the section/at station including its associated all indoor equipments, Indication panel, monitoring console/interface computer and wiring the same to integrate with the relay circuits including supply required power cable of multistrand 10 sq.mm or more from power room to central evaluator, 2 core shielded cable of required size copper conductor as per as per IRS (S)76/89(Amd.3). or IS 694/2010. with latest amendment as applicable with other accessories as per the instruction of Rly engineer at site and earthing as per OEM's technical requirement and specifications. This also includes laying & termination of cable, if any from panel Room to Axle couter room/Relay room in DWC pipe with contractor's material/existing ladder.

-

-

48

... More
Installation, wiring & Testing / commissioning of Axle counters Reset Box of all types in 49 cabin/Panel Room and wiring the same to integrate with the axle counter as per instructions of Railway Engineer at site. This includes laying & termination of cable, if any from panel Room/Axle counter room/ Relay Room to Reset Box in DWC pipe/existing ladder.

2

9033

18066.68

... More
Installation, fixing and wiring of Track side Electronic Equipment of Axle counters including its battery & charger (if required), foundation and earthing as per OEM's technical 50 requirement and specification associated Relays in apparatus cases, location huts, relay rooms etc., with contractor's wiring material, termination of tail cables on terminals/fuse blocks, supply and making axle counter parameter history cards, all activities as per standard practice and technical specifications.

4

19853

79412.6

... More
Installation of complete assembly of track device/double rail contact unit for entry or exit with conductors all material including drilling of required sizes holes on rails for fixing these, taking the cable lead through anti-rodent, anti-oxidant & non-flame propagating type Double walled 51 corrugated (DWC) pipe as per RDSO/SPN/204/2011 Ver 1.1 with Amd.1 or latest from track device to location box and terminating it on terminals including digging of trench under track and up to location/Track side unit and all other accessories as pr site requirement for laying of transmitter and receiver cable with suitable wire embedded rubber pipe with clamp for protecting these cables at DP end. (Note : Unit to be treated as Per Track Device/ Double Rail contact) Per

4

14238

56954.16

... More
Refixing of electrical point machine, ground connection during phase working (Non 53 interlocked working) after removing the existing fitting if any, adjustment if necessary, cable termination, wiring, testing and commissioning of electrically operated point, fixing and connecting point indicator on derail switch if necessary. The work shall be done as per extant practice on C.Rly & the instruction of Rly engineer at site. (Note: Unit to be treated as Per Turnout)

40

5369

214796.4

... More
Fixing of point machine on newly laid turnout on Wooden/MBC sleepers, fixing of ground connections, adjustment and testing with crank handle operations, Removal of ground 54 connection & point machines duly numbered. The will include fixing of bend pipes with welded frame for cable entry to machine. This will also includes necessary adjustment and smithy work, drilling of holes to tounge rails, fitting of insulation for tounge attachment, gauge plate & stretcher bars, cable termination & wiring if required. The work shall be done as per extant practice on C.Rly & the instruction of Rly engineer at site. (Note: Unit to be treated as Per Turnout)

40

4161

166464.4

... More
Installation, fixing and wiring of Boxes for key Lock Relays with contractor's wiring & fixing material. The work shall be done as per extant practice on C.Rly & the instruction of site engineer.

3

3680

11042.64

... More
Excavation of cable trench as per cable route plan, 1.0 mt. deep and 300mm wide along side thew track in normal soil/strata, conforming to distances as per cable route plan and refilling after cable laying. This work includes covering of cable laid to trench by loose soil for a layer 56 of 50mm thickness after clearing of route, bushes etc. It shall be ensured that top of the cables laid is at a depth of 0.8 m or more. If it is less, then the width and depth shall be suitably increased and accordingly proportionate payment shall be made. In case depth of trench is not achievable due to site conditions, proportionate payment will be made as per procedure. The work shall be done as per extant practice on C.Rly & the instruction of Railway engineer at site. Drg No SK 805. (Note : Unit to be treated as Cubic Metre)

1800

413

743400

... More
Excavation of cable trench as per cable route plan, 1.0 mt. deep and 300mm wide along side the track in hard soil, conforming to distances as per cable route plan and refilling after 57 cable laying. This work includes covering of cable laid to trench by loose soil for a layer of 50mm thickness after clearing of route, bushes etc. It shall be ensured that top of the cables laid is at a depth of 0.8 m or more. If it is less, then the width and depth shall be suitably increased and accordingly proportionate payment shall be made. In case depth of trench is not achievable due to site conditions, proportionate payment will be made as per procedure. The work shall be done as per extant practice on C.Rly & the instruction of Railway engineer at site. Drg No SK 805 (Note: Unit to be treated as Cubic Meter)

400

688

275332

... More
Cutting of all types of Roads/platforms (except concrete type) for trenching and 58 excavation to depth of 300mmx300mm wide approx. and refilling after laying of RCC/GI/DWC pipe & to restore them to original condition. The work shall be done as per extant practice on C.Rly & the instruction of Railway engineer at site. Drg No SK 807 (Note: Unit to be treated as Cubic Metre)

15

3441

51625.05

... More
Digging of trench 1.0 M deep from rail flange/road level (for LC) and, 0.3 Mtr to 0.6 59 Mtrs wide and back filling after placing of DWC/RCC/GI pipe. (Placing of DWC/RCC/GI pipe coverd separately). The ballast disturbed be screened and dressed as required by Engineer-in-charge or his representatives and road tarred immediately. Drg No SK 806. (Note: Unit to be treated as Cubic Meter)

120

688

82599.6

... More
Laying of DWC/RCC pipes along with collars / RCC Half round pipes in trenches at places of track and road crossings, platform cutting etc. 61

4500

67

301860

... More
Laying of signaling/Power/Telecom cable of various cores/sizes in trenches.

400

6132

2453184

... More
Laying of RCC Trunking and capping and sealing after cable laying as per std practice on C.Rly & the instruction of site engineer.

4000

83

334120

... More
Provision of brick masonary duct as per Rly.Drg.No.PA/N/CN/STD/19 (modified) after cutting of platform/excavating the earth for the duct with contractor's own materials and restoring the excavated earth to its original condition.

100

2401

240112

... More
"Whereever depth of 0.5 m cable treanch is not feasible, cable shall be protected as 64 under:- Preparation of cement mixture 1:3:6 with contractor's own materials and spreading cement concrete mixture layer of 100 mm thick over the already laid cables in the excavated trench." (Note: Unit to be treated as Cubic Meter)

40

6288

251554.8

... More
Fixing of modular terminal/fuse blocks along with all accessories with provision of fixing 65 holes on hylam sheets/side angles of Loc Box and fixing by galvanized nuts & bolts. This includes fixing on DIN channel along with PVC Comb type 'C' channel (size 2 inch x 2 inch) for cable termination of modular terminal. The PVC channel with cover to be supplied by firm as required. The work shall be done as per the instruction of Rly engineer at site.

6000

22

134880

... More
Termination of cable cores on ARA terminal/Disconnecting link/fuse blocks, in the 66 apparatus Cases/ cable termination rack. This includes all associated works of pulling out the cable from underground. The work shall be done as per location plans and instructions of Rly engineer at site.

24000

8

201120

... More
Laying of GI pipes in on bridges/culverts/concrete drain/ mountain ridges etc. with 67 suitable GI bend shall be provided where there is turning of pipe as per instructions of the site engineer. GI Clamps at every 2 m as shown in the drawing to be fixed. suitable holes to be made in the pipe before laying as per instructions of the site engineer. 100 mm dia. Drg No SK 808

300

169

50814

... More
Horizontal boring of cable duct of minimum 2.0 Mtr depth along with laying of 120mm HDPE pipe for track crossing with minimum depth reckoned from bottom of the rail/Road crossing with minimum depth reckoned from ground level. The work shall be done as per extant practice & 68 instructions of site engineer. Preparation of site for Horizontal Boring shall be carried out in presence o f Railway Representative. HDPE will be supplied by Railway. Note:- Contractor shall provide all material required for boring and adequate nos. of labours for proper laying of cables into the bore. Cable shall be laid cautiously so that it should not get damage due to rough handling & pressure on cable.

3000

3080

9241020

... More
Horizontal boring of cable duct of minimum 2.0 Mtr depth along with laying of 120mm 69 HDPE pipe for Other location with minimum depth reckoned from the ground level. The work shall be done as per extant practice & instructions of site engineer. Preparation of site for Horizontal Boring shall be carried out in presence of Railway Representative. HDPE will be supplied by Railway. Note:- Contractor shall provide all material required for boring and adequate nos. of labours for proper laying of cables into the bore. Cable shall be laid cautiously so that it should not get damage due to rough handling & pressure on cable.

-

-

2475245

... More
Termination of Tail cable inside the point machine through bend pipe this includes preporatory work of pulling the cables, and peeling out the insulation, dressing and lacing after 70 termination etc., pulling of tail cable as per circuit requirement inside point machine through bend pipe, termination of cables on terminal blocks as per instruction of site supervisor the cable shall be entered in such a way that, armouring shall protect the cable near sharp edge of entry point and armouring shall be clamped between pipe fixing bracket and boy of point machine.

80

455

36421.6

... More
Laying of RCC half round cement pipe of approximate size (150/300 mm dia X 2 Meter length) inside the trench after laying of cable. Pipes shall be placed as per directives of engineer.

3000

43

129030

... More
Painting two coats of synthetic enamel paint over one coat of primeron the following after scrapping and cleaning of the surface wherever necessary with contractor own supply of paints. 72 Wherever required contractor shall apply coating of epoxy paint also as per insructions of site-in- charge. Epoxy will be supplied by Railways. NOTE:- The paint and primer should be from M/s Asian paints Co. Ltd.,. The paints will be primer (IS 5660 of 1970) the Aluminium synthetic block enamel (IS 2932 of 1974) brilliant white and yellow Painting two coats of enamel paint over one coat of primer.

-

-

218845.13

... More
Lettering / Numbering Termination particulars, equipment names etc., legibly and neatly inside location boxes.

-

-

66597

... More
Installation testing & commissioning of the 25 W VHF system including the erection of mast, antenna, charging of the battery with all contractor's materials.

2

10179

20358.3

... More
Releasing of lever frame, old location boxes, signal posts, equipment inside the 75 location boxes, lifting barrier, rodding run, cranks, compensators, relays and relay racks, power equipments etc as applicable including breaking of foundation etc as per the instruction of Rly engineer at site & their transportation to SSE in-charge at nominated depot.

1

76066

76066.76

... More
Loading, un-loading & transportation of material from the stores of SSE(SIG) depot or any other nominated place & vice-versa. (Note : Unit to be treated as Per Ton/Per Km)

10000

5

59900

... More
Jointing of 4 / 6 quad cable with Heat shrinkable straight through jointing kit for 4/6 quad cable. 78

40

4203

168135.2

... More
Laying of HDPE duct in trench and its protective work as per direction of site engineer.

30

7242

217284

... More
Blowing/Drawing of OFC cable in HDPE/DWC duct and protective work, as per direction of site engineer.

30

15389

461692.8

... More
Splicing (Jointing 2X24 F OFC) and testing of 24 fibre OF Cable and making the splice joint as per direction of site engineer with contractors own splicing machine & tools. Splice loss of each fibre should be less than or equal to 0.05db splice reflectance should be better than 60 db.

25

7435

185879.5

... More
Design, manufacture & supply of HOT stand-by Architecture Electronic Interlocking(EI)system complete as per RDSO SPN No.RDSO/SPN/192/2019 or Ver.2.0 with latest 1 ammendment, as per technical requirement & tentative approved Signalling Plans & Diagrams. Electronic interlocking (EI)system mainly consisting of central processing equipment, interface equipment /relays etc. as per requirements, Dual operator Industrial Grade VDU Panel (55"LED or more) with Redundancy (HOT stand-by dual VDU normally one system on line and other system in stand-by mode) All interfacing relays suitable for EI, interconnecting cables & Jumper wires, Industrial grade maintenance Terminals (32"LED with UPS minimum 1 hr back up), required power supply converters for EI equipments, protocol Converter for Data Logger, Housing for EI equipment & relay racks,fuses ,screw less disconnecting type terminals, fixture mounting arrangements & accesories necessary to make the EI system functional as per approved signaling plan. The tenderer should furnish complete details of cards/modules/sub-modules connectors etc. for each station. Supply of 15% essential spares of the EI equipments subject to minimum one of each type mainly consisting of processor,cards/ module, interface relay etc. Item wise detailed break up with unit and quantity to be provided in separate annexure. (Inspection Agency -RDSO)

-

-

62665495.15

... More
Transporting and supply and installation of concrete(RCC) route indicators at intervals 2 of 50 meters as per technical specification. They should be standard RCC with Letters on one side "CR" and other side "S&T cables" as per drawing SK 12/10 of RVNL SC. In case of Telecom quad cable joint locations, it shall be painted with RED colour.(Insp Agency - Consignee)

200

1180

236188

... More
Providing Road Breaker/concreate breaker/ boulder or rock breaker with compressor & 3 Jack Hammer for Railway work such as cutting & dismantling of road concrete/Brick pucca structure (RCC/Steel section)including contractors fuel, driver and all other charges.(NOTE : Unit to be treated as Per Hours)

20

1474

29489

... More
Supply of HDPE Pipe 110mm PN6PW100 (Insp Agency- Consignee) (NOTE : Unit to be treated as Per Meter)

4000

595

2382680

... More
Supply of 19" (approx) covered racks, Vero President/Rittel make or similar having size of approximately2.2 Mtr. Height x 600mm width x 600mm depth (size may varies according to site requirement) and duly approved by the engineer in charge of the work. The rack shall be complete 5 with all fittings for housing KLCR equipment, Reset Boxes, Crank Handle, Wago Terminals , other Misc Indication Panel Equipments like runway ladders etc. (fan and power supply arrangement etc.) completely wired and equipped with LEDs and push Buttons for all KLCRs as per technical specification and other stipulations of tender document. It should be possible to lock all the equipment. Before supply the sample of the same shall be approved by engineer in charge (Insp. agency- Consignee)

2

45735

91471.46

... More
Supply of Multi Lamp Route Indicator (LED Single Digit) from 1 to 9 with white LED (without housing); details- Single digit LED route indicator capable of displaying 1 to 9, visibility of 400 6 m in clear day light, option for white colors chromaticity as per BS-1376 standard, LED's with junction temperature > 100 degree C, lamp proving compatible with normal bulb type multi lamp route indicator, retrofits the existing conventional multi lamp type route indicators, input operating voltage 110V AC +-20%, uniform intensity over entire operating range operating temperature -10 degree C to +60 degree C. (Inspection agency: Consignee)

4

56663

226652.4

... More
Supply, installation, wiring and commissioning of bumpless power supply auto 7 changeover device complete along with accessories using contractor's own wiring and fixing materials as per following configurations: 1. Power supply -AC/DC 2. Voltage 24V -150V 3. Current upto 45A. Note: it should be compatible for MSDAC.(Insp Agency - Consignee)

12

36895

442748.4

... More
Steel cupboard (plain storwel) size 6' x 3' Godrej Make or similar .(Insp Agency - Consignee)

2

9211

18423.92

... More
Supply of Panel Operator/Relay room chair Model PCH-7001 Godrej make or similar. (Insp Agency - Consignee)

4

8784

35137.96

... More
Supply of Panel Operator/Relay room record table T-102 Godrej make or similar. (Insp Agency - Consignee) 11

4

10355

41421.64

... More
Supply of chair model PCH-7003 Godrej make or similar.(Insp Agency - Consignee)

8

6299

50399.2

... More
Supply of steel stools Godrej make Model No. ST2 or equivalent.(Insp Agency - Consignee)

12

1454

17454.24

... More
Supply of high availability single section Digital Axle Counter system complete with dual sensor as per RDSO/SPN/177/2012 (version 3.0) or latest consisting of - Track side High availability Digital Axle Counter Unit DACF-720P -2Nos. High frequency Tx coil and Rxcoil (AD-711) 13 (each set consists of web mounting type 2 Nos. Tx coil and 2No Rx coil) -02set Vital relay Box VR722- 2nos .duly wired with following relays a) Vital relay QN1K, 24V 6F-6B -2Nos . b) Reset relay QN1K, 24V 6F-6B -1Nos. c) PR relay QNN1 , 24V 6F-2B(dual)-1Nos. Clamp with deflector plates & hard ware, 4Nos. Reset box model no 259A-2no . Surge Voltage protection Device Mounted on Din Rail-2nos. (Inspection Agency - RDSO)

4

814050

3256200

... More
Radio detection Precision Pipe and Cable locator / Route tracer. Brand: Radio detection Make -RD8200G or similar (Inspection By consignee)

1

501735

501735

... More
Supply of SOT-18 Branching CARD with minimum 02 nos optical & 02 electrical SFP 15 MODULES compatible to work with TEJAS STM1 & STM4 TJ1400 As per TEC Spec No.GR/TX/SDH-010/03 Jan 11 Firm's Offer - SOT18 Card with optical S1.1 SFP(04 nos per card) compatible with TJ1400 model equipment Make/Brand - TEJAS SOT18 Card with optical S1.1 SFP or similar (Inspection by Consignee)

5

75097

375486.4

... More
Supply of Fibre distribution management system (As per RDSO/Spec IRS-TC-37/2000 16 Ver-3 with latest amendment or latest) Birla 3 M / TVS R&M make rack mounting type suitable for 48 fibers with 48 pig tails, SC/PC connectors splicing tray etc. Confirming to TEC Spec No GR/FDM-01/01 Dec-99 or latest (Insp. agency- Consignee)

15

18000

270014.7

... More
Installation of Fibre distribution management system with all installation material, splicing and termination of OF cable 2X24 F (with all contractors tools & material).

15

2555

38330.25

... More
Supply of LC to SC Single Mode Simplex/Duplex Fibre Optic Patch Cable 5m length. (Insp. agency- Consignee)

100

201

20178

... More
Supply of Switch Board indoor cable, Delton/Finolex/Bhansali make ((Insp. agency- Consignee) 20

-

-

75440

... More
Supply of Industrial Casing Capping 1x1 inch. (Insp. agency- Consignee)

1000

92

92340

... More
Fixing of Industrial Casing Capping and Laying of tele/data cable in same casing (Insp. agency- Consignee)

1000

15

15570

... More
Supply of composite rack 19" of standard reputed make with fixing arrangement for mounting 2 wire DTMF way side equipment.(Insp Consignee)

5

11260

56301.45

... More
Supply of Cat-6 cable with identifications marking on cable at regular interval of make D- Link, Opt link, Dig link, Baton, Network, Krone or similar. (Inspection by Consignee)

1500

16

25230

... More
Supply of programmable primary Digital Drop/ Insert multiplexer with conference facility as per technical specifications IRS T-68-04 with amendment no.1 or latest as on the date of opening of tender wired complete with power supply, control and basic./common accessories cards remote control supervision facility and all others accessories, installation material, connecting cables(minimum 5 m length) with suitable connectors for taking out the MUXs out put for all the 24 channels, technical manuals etc also 91) the MUX shall be equipped for 5 Nos of 4 w/2W E & M Cards interface card four circuits(16 circuits). 2) 1 No of 2 W Exchange interface card four circuits (4 circuits). 3) 01 Nos of Hot line/ subscriber loop interface cards for four circuits (8 Circuits). 4) 1 Nos of 64 kbps co directional data card for four circuit (CCITT G 703) 4 circuits( 5) The PD mux should be RDSO approved on the day of tender opening). Mux should be compatible with existing system. Combination of card will be decide by rely site engineer (PD MUX compatible as existing system ,PUNCOM VT-100). (Insp. agency- Consignee)

5

108608

543043.6

... More
Installation, wiring, testing and commissioning of PDMUX, surge and lightning protection arrangement with all accessories in already provided in racks. This includes connecting primary Mux equipment with all interface cards to the 48V bus including supply of wires and connectors, termination of VF interface circuits to the Krone type MDF at both mux and cable ends including taking cable over runway or a wall and installation and wiring of U link panel in the rack. More than one primary multiplexers etc. may have to be installed at some stations. This work also includes transportation of materials from stores. supplied by Railways for installation. All other miscellaneous materials including PVC conduits/Casing and capping, required no of U link panel etc. should be supplied by the contractor. adject combination of card combination will be decide by site engineer

-

-

25

... More
Earthing of armour of PIJF /6 Quad Cable, the earth to be extended from the earth electrode to the armouring of cable and Telecom equipment like battery charger, Control Equipment etc.

60

515

30909

... More
Fabrication of EC Socket Assembly and Erection of Fabricated Assembly at Location as per instructions of Site Engineer In Charge. This includes supply and cutting of perforated GI Pipe (50 mm dia min) of suitable length with fittings, bend pipe and welding of the bend pipe and MS Plate with GI Pipe, fixing of Socket Box, transportation of material to site, digging of pit and erection of whole assembly, its foundation by brick masonry as per drawing with contractor's own material. Termination 27 of Derivation Cable on strip inside the socket box as per Drawing No. Dy.CSTE/C/Tele/SK/90/06. GI Pipe of IS 1239 of 1992. Note: One sample of Fabricated Assembly should be approved by Site Engineer before bulk Supply. This includes wiring of 1T VF Transformer inside EC Socket Box as per instructions of Railway Engineer AND Painting of EC Socket Assembly (includes All Posts, Sockets, Pipes, Plates) by applying one coat of Red Oxide as base colour. Painting of the assembly in Zebra Patterns of Black and Silver Colour strips of 100 mm width. This includes Supply of required Paints of reputed company with ISI mark. The various Paints should be approved by Site Engineer before commencement of work. Note :- Samples of the fabricated post to be got approved from Rly. Engineer I/C before bulk supply.

20

5026

100536

... More
Fixing of the EC Socket Complete with termination of derivation cable on strip inside the EC Box duly mounted on good quality Teak wood/hylum board at S.M. building/ Cabin & wherever necessary as per instruction of Engineer in charge.

20

754

15094

... More
Supply of Isolation derivation Transformer of various types as per exact requirement of Rly Engineer In charge. (Insp. agency- Consignee)

-

-

43791

... More
Supply of cable termination Panel as per Drg no- SK/CSTE(C)\97\26, fitted with 12 Nos. of 32 way U link feed Panel along with U links complete and mounting arrangement for isolation transformers. (Insp. agency- Consignee)

4

28313

113252.12

... More
Installation of cable termination Panel as per Drg no- SK/CSTE(C)\97\26, mounting of Isolation transformer, termination of U/G cable on U Link panel, supply of wiring material and wiring of circuitry as instruction of engineer in charge.

4

5235

20940.92

... More
Supply of LC Gate Telephone system as per Specification No RDSO/SPN/TC/51/2011 (Rev-3) Amendment-1 or latest with voice logging facility. (Insp. agency- RITES)

-

-

40733

... More
Hilti PD-E Laser Meter Kit Measurement Range 0-200 m, or similar Fluke make or Bosch make. (Insp. agency- Consignee)

5

63998

319992.4

... More
Deployment of Manpower like un-skilled Labour for to work in emergencies or as required during cable shifting, finding the existing cable route, shifting & placing of materials in depot etc.

400

561

224504

... More
Deployment of Manpower like skilled Labour for supervision & technical support in emergencies or as required during cable shifting, finding the existing cable route etc.

400

620

248216

... More
Desk type 2 wire/12 way DTMF Selective Telephone as per RDSO Specification No. IRS- TC 80/2000 With amendment no. 03 or latest. MAKE:EPSILON (Insp. agency- Consignee)

20

2212

44250

... More
Supply of insulation mat (Rubber Mat) for electrical purpose 2.5 mm thick size 2m x 1 m suitable for 3.3 KV to 11 KV (Class B) conforming to IS 15652-2006. (Insp. Agency - Consignee)

180

1354

243849.6



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.