Central Railway Tender

Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.

Central Railway - CR Tender

Works
Telecommunication Services
Ireps
+1Nashik, Maharashtra
Opening Date23 Dec 2024
Closing Soon15 Jan 2025
Tender Amount₹ 21,91,57,889.55 
Notes
Download

Costs

Summary

Supply, Installation, Testing & Commissioning Of Indoor & Outdoor Signaling Work including Provision Of Electronic Interlocking At Mhasawad & Nandgaon (ph Ii) stations And Leftover Work

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply of PVC Indoor Cable 1 x 24 x 1 mm dia Colour coding of insulation of inner conductor shall be in eight colour viz Blue, Red, Grey, Green, Brown, Black, Yellow & White conforming to IRS 76/89 (Amd.3) or latest. (Inspection by RDSO)

3

292637

1035937.74

... More
Supply of PVC flexible copper cable single core multistrand 1 x 2.5 Sq.mm (50 5 conductor each diameter 0.25 +/- 0.01) as per IS 694/2010 with latest amendment if any.with insulation thickness of 0.70mm nominal conductor resistance 7.98 ohms/Km and test parameters are as per IRS (S)76/89 (Amd.3). (Inspection by RITES)

14

44575

736389.74

... More
Supply of PVC flexible copper cable single core multistrand 1 x 6 Sq.mm (84 conductor 6 each diameter 0.30 +/- 0.01) as per IS 694/2010 with latest amendment if any.with insulation thickness of 0.80mm nominal conductor resistance 3.30 ohms/Km and test parameters are as per IRS (S)76/89 (Amd.3). (Inspection by RITES)

8

91617

864867.41

... More
Supply of PVC flexible copper cable single core multistrand 1 x 10 Sq.mm (80 7 conductor each diameter 0.40 +/- 0.01) as per IS 694/2010 with latest amendment if any.with insulation thickness of 1.0mm nominal conductor resistance 1.91 ohms/Km and test parameters are as per IRS (S)76/89 (Amd.3). (Inspection by RITES)

12

141059

1997399.69

... More
Supply of PVC flexible copper cable single core multistrand 1 x 16 Sq.mm (126 8 conductor each diameter 0.40 +/- 0.01) as per IS 2465/1984 & IS:694/2010 with latest amendment if any with insulation thickness of 1.0mm nominal conductor resistance 1.121 ohms/Km and test parameters are as per IRS (S)76/89 (Amd.3). (Inspection by RITES)

8

209928

1981723.15

... More
Supply of PVC flexible copper cable single core multistrand 1 x 25 Sq.mm (196 9 conductor each diameter 0.40 +/- 0.01) as per IS 2465/1984 & IS:694/2010 with latest amendment if any with insulation thickness of 1.2mm nominal conductor resistance 0.780 ohms/Km and test parameters are as per IRS (S)76/89 (Amd.3). (Inspection by RITES)

4

326216

1539741.74

... More
Supply of low maintenance Lead Acid Secondary Cells 2V 80 AH as per spec. IRS 88/2004 with latest amendments. (Inspection by RDSO)

450

1997

1060491.96

... More
Supply of Transformer 230V/110V-130V Single Phase 2 KVA as per spec. IRS S-72/88 (Amd.2) with latest amendments. (Inspection by RDSO)

20

10876

256691.06

... More
Supply of Battery Charger self regulating floor mounting type with 230 V AC single phase input and output 60 V DC, 20A as per spec. IRS.S.86/2000 (Amd.4) with latest amendments for Axle counter applications(Inspection by RDSO)

6

52992

375188.1

... More
Supply of Battery Charger self regulating floor mounting type with 230 V AC single phase input and output 24 V DC, 10A as per spec. IRS.S.86/2000 (Amd.4) with latest amendments. (Inspection by RDSO)

16

40356

761930.91

... More
Supply of Battery Charger self regulating floor mounting type with 230 V AC single phase input and output 24V DC, 30A as per spec. IRS.S.86/2000 (Amd.1) with latest amendments for Axle counter applications (Amd.4). (Inspection by RDSO)

6

59719

422813.35

... More
Supply of Rubber Mat 10mm thick for use in signalling installation. (Inspection by Consignee)

300

129

45853.62

... More
Supply of Automatic changeover for individual supply. Automatic changeover unit of 16 signal/Track/ DC circuit supply of 32A, AC/DC consisting of 3TC44 contractors, LED Lamp, Push Button, terminals, VSR, polarity switches. As per Rly. Drg.-SK-841/1-5 for IPS supply to mannual discrete equipments with P/switch. (Inspection by RDSO)

28

29381

970767.4

... More
Supply of Switchgear unit consisting of 2/3 pole switch fuse unit along with programme 17 switches, fuses of suitable rating, meters, indications etc. of approved make and as per Central Railway practice. General arrangement to be approved by Engineer incharge. Make Siemens, L&T, or Havells. (Inspection by RDSO)

28

116424

3846648.96

... More
Resin percentage as 63% SN (Tin) and / 37% Pb (Lead) with percentage of various impurities not exceedingcored wire as per specification No. IS:1921-1975 with Alloying element the values Sb (Antimony) 0.2% maximum , Cu (Copper) 0.1% maximum, As (Arsenic) 0.05% maximum, Fe (Iron) 0.02% maximum & other impurities mainly Al, Zn & Cd shall be limited. The flux shall be free from corrosive action as per clause 5.2 & flux percentage may be used as per requirement. (Inspection by Consignee) 19

30

1252

44341.33

... More
Lacing thread rolls, black, wax coated (100 mtrs). (Inspection by Consignee)

150

66

11708.55

... More
Design, fabrication and supply of Fuse Auto Changeover System for 32 Nos. of external non-deteriorating type fuses or 'G' type fuses from 0.6 Amp to 4 Amp capacities used in signalling circuits. System shall have 8 cards with monitoring arrangement of 4 fuses in one card. As per RDSO Spec. RDSO/SPN/209/2012 Ver.2.0 or latest amendment if any. (Inspection by RDSO)

102

2729543

3220861.28

... More
Design, fabrication and supply of Fuse Auto Changeover System for 24 Nos. of external non-deteriorating type or 'G' type fuses from 4 A to 10 Amp capacities generally used for point operaton circuits. System shall have 6 cards with monitoring of 4 fuses in one card. As per RDSO Spec. RDSO/SPN/209/2012 Ver.2.0 or latest amendment if any. (Inspection by RDSO)

6

243080

286834.73

... More
Supply of Main Signal Post 140 mm outer dia 3.6 Mtr Length as per spec No IRS S 6/81 with latest amendments. (Inspection by RDSO)

23

6832

185426.45

... More
Supply of Main Signal Post 140 mm outer dia 4.6 Mtr Length as per spec No IRS S 6/81 with latest amendments. (Inspection by RDSO)

46

6948

377164.58

... More
Supply of Main Signal Post 140 mm outer dia 5.6 Mtr Length as per spec No IRS S 6/81 with latest amendments. (Inspection by RDSO)

6

9233

65372.47

... More
Supply of Shunt Signal Post with Base (GI Pipe of 80 mm Dia of min. 1 meter length.). (Inspection by Consignee)

29

2711

92799.51

... More
Supply of Cast Iron Main signal surface base 140mm as per spec No IRS S-10 and Drg 26 No 2011/M with latest amendments, with CLS Ladder assembly complete for CLS signal 5.5/4.5/3.5 mtrs long as per RDSO Drg. No. SA-23156(Adv), SA-23153 (Adv) & SA-23150 (Adv) Alt. 1 respectively with Latest Amendment as the case may be for CLS unit & signal back staging as per extent C. Rly practice (Inspection by RDSO)

73

9034

778199.1

... More
Supply of Cast iron Shunt signal surface base 80 mm as per spec No.IRS S 10 and Drg No.2011/M with latest amendments, as per RDSO Drg No. SA-23156/Drg.No.RST/11413 as per extent C.Rly practice (Inspection by Consignee)

29

2071

70898.36

... More
Supply of Signal No.plates. as per Drg No RST-11393 / SK-842 (Inspection by Consignee)

102

521

62790.61

... More
OFF set bracket 5-1/2 " to suit 140 mm dia CLS Post with two no. of "U" Bolts with nut & washer complete as per RDSO Drg.No.SA-23080 for Signals & Routes (Inspection by Consignee)

15

999

17695.4

... More
Supply of A/AG/C/P/G/IB Board as per Drg. RST-11444/1(A), RDSO Drg No SA 23460(AG), SA-23461( C), RST-11445. SA 23456(P), SA 23477(G) & SA 23476-77(IB) as applicable respectively with Latest Amendment. (Inspection by Consignee)

32

561

21211.3

... More
Supply of Stop Board as per RST-11791 (STOP BOARD)/ RDSO Drg No.7235/B as per extent C.Rly practice. (Inspection by Consignee)

10

3340

39413.3

... More
Supply of different warning Boards as per Block section limit Board as per RDSO Drg.No. SA 2373 Paint and retroreflective arrangement as per Railways drawing. (Inspection by Consignee)

4

3252

15349.77

... More
Supply of Hand Cuff Locks/ Godrej Navtal lock with Three common keys. (Inspection byConsignee)

230

286

77674.68

... More
Supply of 2 Aspect signal unit in FRP body without lences & transformer as per Drg. No. 34 SA-23003 A/M Alt-S or latest & RDSO Spec. No. RDSO/SPN/194/2006 Rev. 2.0 or latest & complete & to suit LED Signal lamps and suitable for 140 mm post saves pigment finish on the backside of the and inside, white pigment finish inside the 2-aspect unit to avoid any extra paint cost.(Inspection by RITES)

32

30939

1168272.12

... More
Supply of 3 Aspect Signal unit in FRP body without lences & transformer as per Drg. No. 35 SA-23002 A/M Alt-S or latest & RDSO Spec. No. RDSO/SPN/194/2006 Rev. 2.0 or latest complete & to suit LED Signal lamps and suitable for 140mm post saves pigment finish on the backside of the and inside, white pigment finish inside the 3 Aspect unto to avoid any extra paint cost. (Inspection by RITES)

37

31708

1384414.5

... More
Supply of 4-aspect signal unit in FRP body without lences & transformer as per Drg. No. 36 SA-23001 A/M Alt-S or latest RDSO Spen No. RDSO/SPN/194/2006 Rev.2.0 or latest complete & to suit LED Signal lamps and suitable for 140 mm post saves pigment finish on the backside of the and inside, white pigment finish inside the 4-aspect unit to avoid any extra paint cost.(Inspection by RITES)

5

41024

242044.9

... More
Supply of Shunt Signal position light type FRP complete as per RDSO Specification No. 37 RDSO/SPN/194/2006 Ver 2.0 or latest with offset bracket 3-1/2" to be fitted on 140mm post as per drawing No. SA-23840 (Adv) Alt-2 for dependent type complete without signal unit bracket, terminals, lenses, lamp, lamp holder, and to suit LED Signal lamps. (Inspection by RITES)

21

13950

345687.69

... More
Supply of 1-way junction Route Indicator to FRP body without lenses and transformers as per RDSO Drg. No. SA-23401 with latest Alteration & as per RDSO Specification No. RDSO/SPN/194/2006 Rev.2 or latest complete & to suit LED Signal lamps. (Inspection by RITES)

12

35033

496071.53

... More
Supply of 2-way junction Route Indicator in FRP body without lenses and transformers as per RDSO Drg. No. SA-23402 with latest Alteration & as per RDSO specification No. RDSO/SPN/194/2006 Rev.2 or latest complete & to suit LED Signal Lamps. (Inspection by RITES)

5

45194

266648.26

... More
Supply of 3-way junction Route Indicator in FRP body without lenses and transformers as per RDSO Drg. No. SA-23403 with latest Alteration & as per RDSO specification No. RDSO/SPN/194/2006 Rev.2 or latest complete & to suit LED Signal Lamps. (Inspection by RITES)

1

49751

58706.5

... More
Supply of "Calling On" Signal Unit in FRP body without lenses and transformers as per RDSO Specification RDSO/SPN/194/2006/Rev.2.0 or latest complete and to suit LED sigal Lamps. (Inspection by Consignee)

12

8669

122763.66

... More
Supply of Phenolic 10mm thick sheet, grade P3 in standard size of 1.22X1.22 Mtr as per spec. No IS 2036 of 1995. (Inspection by RITES)

170

5250

1053246.29

... More
Supply of ARA Terminal blocks with links made of PBT Specn No.IRS/75/2006(Rev-2) with latest amendments and RDSO Drg.No.SA-23741A Alt.4, SA-23745 Alt.5, SA-23746, SA-23748 Alt.4 & SA-23756A Alt.3. (Inspection by RITES)

51000

72

4369669.8

... More
Supply of cartridge fuse block made of PBT as per RDSO Drg No SA-23748 Alt 4, SA- 23749 & Spec No IRS S 75/2006 with latest amendment. Fuse block shall be suitable for round head type voltage fuses. (Inspection by RDSO)

650

162

124974.98

... More
Supply of round head type non detoriating type low voltage cartridge fuse as per Specn No IRS/S/78/92 with latest amendments 2A/4A/6A capacity (Inspection by Consignee)

1400

70

115854.76

... More
Supply of Tik-tak, piano type switches,5 A (as per IS Specification). (Inspection by Consignee)

200

33

7884.76

... More
Supply of three pole plug and socket 5 Amp (as per IS Specification). (Inspection by Consignee) 48

200

230

54482.96

... More
Supply of Lamp 110V/24W, 2 Pin for Loc. (Inspection by Consignee) 49 105.00 Numbers 16020.05 1682105.25 18.00 1984884.20 49

200

22

5364.28

... More
Supply of Apparatus Case with godown locks with detachable handle on both the doors. - Single Case as per Drg. No.SK 783-1 & 2 with latest alteration. (Inspection by RITES)

-

-

49

... More
Supply of Apparatus Case with godown locks with detachable handle on both the doors. - Half Case as per Drg. No.SK 783-1 & 2 with latest alteration. (Inspection by RITES)

45

12853

682544.21

... More
Supply of earth electrode assembly as per Drg.No. CR/S&T/SK-815 (Inspection by RDSO)

245

1078

311672.93

... More
A CLASS EARTHING- Supply of ESR ALTEC TERRA STREAMER Lightning Arrester with SS adaptor (TSP30, 50 Mtr. Radius) SPN: NFC-17-102-2011. (Inspection by RDSO)

4

62877

296779.63

... More
Supply of Lighting Strike recorder LSC 6 digit shall be weather proof type.It should 53 have 6 digit event count & the capacity to count smallest strike(3 KA).It should be voltage sensing type counter.So that it will register nearly strikes & static discharge due to induction effect as per IS 2309:1989 (Inspection by Consignee)

4

14747

69609.9

... More
Maintenance Free Earth as per RDSO/SPN.197/ 2008 or latest consisting of : 1) Copper 54 bond steel electrode 3 Mtr long 17mm dia with copper bonding thickness of min. 250 micron & UL listed & marked-01 No. 2) Earth enhancement compound RDSO Approved in sealed bag of 10 Kgs - 03 No. 3) Copper strip 150 x 25 x 6mm - 02 No. 4) Copper strip 300 x 25 x 6mm - 01 No. 5) 35 Sqmm Copper Cable to connect earth electrode to MEEB - 15 Mtr Approx. (Inspection by RDSO)

50

17786

1049393.47

... More
Supply of 35 Sq.mm Multistrand Single Core PVC Insulated Copper for connecting earth bus bar to earth electrode. (Inspection by RDSO)

1500

406

719204.1

... More
Supply of Copper Tape 25x6 mm (Bonding ring conductor) mounted on insulated standoff (1 round). (Inspection by Consignee) 57

550

795

516214.6

... More
Supply of 300x25x6 mm Cu Equipotential Bus Bar. (Inspection by Consignee)

65

1334

102382.99

... More
Supply of Microprocessor based universal earth resistance sensing unit 12 channel AC/DC as per RDSO/SPN/256/2002 with latest amendments. (Inspection by RDSO)

12

145626

2062071.95

... More
Supply of Track Lead Juction Boxes as per C.Rly Drg. No.RST 11509 made from fiiber glass alongwith terminal blocks. (Inspection by RITES)

370

1047

457548.07

... More
Supply of B type choke to specn.No.IRS.S.65/83 (Amd.3) with latest amendments. (Inspection by RDSO)

165

3666

713838.34

... More
Supply of adjustable Track Feed Resistance disc type 7.5/15/30 ohms as per RDSO Drg. No. SA 20161-66/M (Adv) with latest amendments (with Phenolic moulded base). (Inspection by RDSO)

150

1288

228000.78

... More
Supply of Track feed battery chargers, 110V AC input 2, 4 to 6 V DC Output to Specn.No.IRS.89/2013 Ver.1.0 with latest amendments. Charger shall be suitable for charging 80 AH battery. (Inspection by RDSO)

150

2430

430163.1

... More
Supply of Channel Pins single groove, galvanised, 7 mm suitable for 4mm dia bonding wire as per spec No. IRS: S 17-75 Revision 3. (Inspection by Consignee)

3500

2

8301.3

... More
Supply of PVC jacketed wire rope for Track Lead connections. PVC jacketed wire rope 64 should be of Galvanised steel wire rope 6 mm dia (6x19 stranded wire with steel core of 6 mm dia) sheathed with PVC 2mm wall thickness, overall thickness being 10 mm. PVC sheath should be made of type 6 compound as per IS 5831 of 1984 Reaffirmed 2001 and steel wire rope as per IS: 2266:2019. Reclaimed or recycled material should not be used. (Inspection by Consignee)

5000

52

308511

... More
Supply of 8 SWG GI wire (4mm dia) suitable for track circuit rail bonding. As per IRS Specification S:13-62 (Inspection by Consignee)

300

86

30734.28

... More
Supply of Hydrometer, Exide make or similar for measuring specific gravity of Battery Graded acid with mounting stand in location Boxes.Consignee inspection under manufacturer certificate. (Inspection by Consignee)

30

283

10040.86

... More
Supply, installation, testing and commissioning of Track Battery Charger Monitoring System for 2V/4V/6V/8V batteries with accessories at nominated stations. General Scheme to be approved by Engineer incharge. (Inspection by Consignee)

150

1667

295060.77

... More
Supply, installation, testing and commissioning of Remote Indication Unit along with all accessories for above item. (Inspection by Consignee)

4

843

3982.17

... More
Supply of Electronic Timers for DAC reset arrangement 3 sec to 30 sec with 2NO/2NC contact working voltage 24V/60V DC. Siemens/ABB/L&T or SELEC (642XA programmable electronic timer switch) make. (Inspection by Consignee)

35

2819

116436.26

... More
Supply of William stretcher nylon insulation set suitable for ground connection as per RDSO drg No T-10367, T-10368, T-10384 as applicable and to the spec IRS S 23 & 40/84 with latest amendements . (Inspection by Consignee)

100

531

62760.66

... More
Supply of Tongue attachment nylon insulation set consisting of one insulating plate as per Drg no: RST-106961 & 3 nos of Ferrules with collars to suite rodding supplied as per RDSO spec & Drg.no: RST-10692 (Inspection by Consignee)

100

338

39919.4

... More
Supply Gauge Tie plate nylon insulation as per RDSO drg No: T- 10372 Alt2, T- 10368, T- 10371 Alt2, T-15083/88/Alt2 & T-11690/Alt2 and to the spec IRS S 23 & 40 with amendement 01 or latest amendements. (Inspection by Consignee)

100

244

28804.98

... More
Supply of Ground connections, complete set suitable for IRS type/appd. point Machine 73 for ordinary turnout with tounge attachment insulation and other insulation as per RDSO Drg. S / 3361 / 62 / 63 (for IRS type point machine) or RDSO Drg No.SA-9151/52 (for Siemens point machine) with latest amendments. However the ground connection shall be procured only after confirmation from Railway engineer as per site condition /type of machine/turnout. (Inspection by RITES)

20

8171

192843.15

... More
Supply of GI pipe, inner dia. 100mm dia. B-class as per spec. No.IS 1239 PT. 1/2004 or latest with sockets and fittings. TATA/JINDAL/ZENITH BIRLA make. (Inspection by RITES)

600

1029

728758.56

... More
Supply of DWC HDPE pipe with one snap fit coupler and 'O' ring fire resistant, anti rodent, in 6 meter length of size 120 mm outer dia as per RDSO/SPN/204/2011 Ver. 1.1 with Amd.1 or latest. (Inspection by RITES)

6000

321

2275724.4

... More
Supply of RCC pipe half round of size 300mm dia outer and 250 mm dia internal 1 mtr long. matching to IS No.458/2003 amendment-1 with Rev.4.(Inspection by RITES)

12000

422

5979060

... More
Supply of RCC pipes half round of size 150mm dia outer and 100 mm dia internal 1 mtr long matching to IS No. 458/2003 amendment-1 with Rev.4. (Inspection by RITES)

7000

206

1702716.4

... More
Supply of Modular terminal block of 2.5 sq.mm 2 in 2 out type disconnect type terminal 78 along with as per RDSO/SPN/189/2004 Rev 3.0. The current capacity of 16 Amps and more. The terminal should have marking at centre to view description from front. Material to be procured from RDSO approved firms only. (Inspection by RITES) 79

20000

117

2764032

... More
Supply of DIN Channel for the terminals 1 Mtrs each. (Inspection by Consignee) 80

200

216

51148.28

... More
Supply of End plates for modular terminal block. (Inspection by Consignee) 81

2000

23

55200.4

... More
Supply of End Clamp for modular terminal block. (Inspection by Consignee)

700

16

13885.06

... More
Tool bag complete with Megger as per Annexure. ADD AC/DC clamp meter, with Hand Held Tool Bag. (Inspection by Consignee)

4

52213

246447.58

... More
Supply of Adhesive Tapes rolls, PVC (18mmx25Mtr) Steel Grip/SCOTCH/ANCHOR. (Inspection by Consignee)

150

33

5929.5

... More
Supply of Trans-receiver hand held 5 Watt Analog VHF Set along with two sets of OEM approved rechargeable battery including one as spare, quick Battery Charger, Helical Antenna and Belt Clip conforming to RDSO specification no. RDSO/SPN/TC/107/2018 Rev 0.0 with amendment no.1 or later. (Inspection by Consignee)

2

13482

31817.99

... More
Supply of VHF 25W transreceiver (synthesised) set complete consisting of Analog Set as per CR specification. (Inspection by Consignee)

2

23800

56169.39

... More
Supply of 4.5 Kg CO2 type fire extinguisher alog with all accessaries, extinguisher testing certificate has to be supplied along with - Supply of ISI marked Carbon di Oxide type (BC) fire 86 extinguisher of 4.5 Kg capacity confirming to IS 2878:2004 from seamless cylinder, with IS marked control value, high pressure mtr., Long discharge hose and horn complete with initial gas charged with carrying handle and wall mounting braket etc., as required by Site Engineer. (Inspection by Consignee)

40

5019

236902.94

... More
Supply of Block proving by Digital Axle Counter as per RDSO/SPN/188/2004 with latest amendments using UFSBI for Single line BPAC working, RDSO SPN RDSO/ S-32016 or latest complete 87 as per RDSO spec. IRS S:105/2012 (Ver.0) or latest. One pair consists of following : Universal Fail Safe Block interface as per RDSO Spec. No.RDSO/SPN/147/2005 (latest amendments)-02 Nos. SM's Panel (RDSO/S/32019 latest amendment) with all accessories complete-02 Nos. Relay rack with due Locking and sealing arrangement duly wired (As per RDSO/S/32020- including relays)-02 Nos. Relays for double line section will be supplied with prewired relay rack. (Inspection by RDSO)

2

950509

2243203.36

... More
"Supply of Single Section Digital Axle Counter (SSDAC) with two detection point with reset arrangement and vital relay box as per RDSO/SPN/177/2012 Ver.03 or latest. Each set consist of the following:- a) High frequency TX coil and RX coil (Each set consist of web mounting type TX coils-2 Nos. RX coils-2 Nos. along with 10 mtr cable-2 sets), b) Track side digital axle counter unit-2 Nos. c) 24V 6F/4B, 1000 ohm ""Q"" type relay box duly wired-2 Nos. d) Clamp with deflector plates and hardware etc-4 Nos. e) Reset Box-2 Nos. f) Mushroom/Location Box suitable for housing Track side equipment(2 Nos). 2) Transportation, Installation, Testing & Commissioning:- Transportation, Installation, Testing & Commissioning of equipment field training (one man day per set) at site or as desired by Site Engineer. These includes:- a) Foundation and erection of Track side Equipment i.e. 88 Mushroom/ Location Box(if required). This includes supply of all associated materials. b) Individual Earthing of all detecton Point for the OEM recommended earth value certified by OEM Site Engineer. This includes supply & installation of maintenance free earth materials and exothermic bonding and other connecting cable etc as per Railway practice (As per RDSO Spec. No. RDSO/SPN/197/2008 or latest. Resetting equipmet to be connected to the EI Ring earth. c) Installation to be carried out by OEM certified Engineer. 3) Tool Kit consisting of :- a) Digital True RMS multi meter of suitable make for aove Digital Axle Counter System with probe set-1 No. b) Train Simulator (High frequency)-1 No. c) Extender Card-1 No. d) Dummy wheel-1 No. e) Different type of spanners suitable for aove Digital Axle Couner- 1 Set. f) Torque wrenches suitable for the above-1 No. g) Screw driver set suitable for the above-1 Set. h) Carrying Bag for Tools-1 No. i) 6 Nos. Electrostatic Discharge Wrist Band for cards/ modules protection. (Inspection by RDSO)"

11

440628

5719364.16

... More
Supply of QNA1-K AC immunised relay, 6F-6B, 24VDC along with plug board, retaining clip and connectors conforming to BRS:931A & RDSO letter no.STs/E/Relays/ UEA/PI dated 30.05.97 Annexure-II IRS:S60, IRS:S34 & IRS:S23. (Inspection by RDSO)

210

4099

1015972.57

... More
Supply of QNA1 AC immunised relay, 8F-8B, 24 VDC along with plug board, retaining clip and connectors confirming to BRS : 931A, IRS:S60, IRS:S34 & IRS:S23 (Inspection by RDSO)

110

3852

500035.03

... More
Supply of QN1 Non AC immunized natural relay 8F-8B,24VDC along with plug board, retaining clip and connectors conforming to BRS:930A,IRS:S60,IRS:S34 & IRS:S23 .(Inspetion by RDSO)

100

4147

489456.92

... More
Supply of QSPA1 relay, 24VDC, slow to pick up, 8F-4B, along with plug board, retaining clip and connectors conforming to BRS:933A, IRS : S60, IRS:S34 & IRS:S23 (Inspection by RDSO)

160

4414

833538.78

... More
Supply of QTA2 AC immunised track relay, 9 Ohm, 2F.1B, along with plug board, retaining clip and connectors conforming to BRS:939A, 966 & Appendix F2, IRS:S34 & IRS:S23 (Inspection by RDSO)

135

3859

614869.33

... More
Supply of QBAT track Relay, AC immunised, 2F-2B contacts, 9 ohms. complete with plug board, retaining clip & connectors as per RDSO / SPN/84 Ver 2.0 or latest. (Inspection by RDSO) 95 4.00 Set 62499.33 249997.32 18.00 294996.84

30

6603

233774.17

... More
Supply of MODEM compatible with existing UFSBI system to work on back up media (either VF channel on OFC P/Mux or 2 Mbps E1 channel from STM or direct dark single mode optic fibre cable upto 30 Km distance). (Inspection by Consignee)

-

-

95

... More
Supply of Automatic media changeover of Modems working on redundant channels for data transmission on OFC/Quad/Microwave Radio. (Inspection by Consignee)

4

32526

153522.72

... More
Supply of Key Lock Relay with different ward combinations (three extra set of ward 97 plate for Point Machine to be supplied with each relay). Siemens Make working on 60V DC/24 DC or functional equivalent without base plates. RDSO/SPN/219/2016 Version 1.0 d 1. (Inspection by Consignee)

47

9145

507233.28

... More
Supply, Installation, Testing & Commissioning of Microprocessor based intelligent, addressable, Fire Alarm Control Panel with LCD display complying to RDSO/SPN/217/2019 Ver 3 or latest modular, 1 loop (minimum 125 detector/devices per loop-expadable to 2 loops) with 320 Character with soft keys for displaying alarm, events and operating functions, Day/Night operation 98 function, Remote maintenance service featgure etc. The panel should be multi-protocol i.e. able to support at least 2 different makes of addressable detectors. The pael should have minimum two relay outputs & 1 Monitored Sounder Output. It should have provision to be connected to repeater panels in future. The pael shall capable to operate o 230 volts AC power supply, automatic battery cjarger, 24 volts, sealed lead acid maintenance free batteries sufficient for 24 hours normal working and then be capable of operating the system for 30 minutes during emergecy condition. Panel should be VdS Certified. (Inspection by RDSO)

2

67218

158635.21

... More
Supply, Installation, Testing & Commissioning of Manual call points, complying to RDSO/SPN/217/2021 Ver 3 or latest. As per latest VDS approved/Listed.( Inspection by RDSO)

23

5226

141849.65

... More
Supply, Installation, Testing & Commissioning of Resettable, Analogue Type Linear Heat Sensing (LHS) Cable complying to RDSO/SPN/217/2021 Ver 3 or latest. As per latest UL or FM or VDS or LPCB approved/Listed.( Inspection by RDSO )

550

1414

917770.37

... More
Supply, Installation, Testing & Commissioning of LHS Interface Module with all accessories for single stretch, complying to RDSO/SPN/217/2021 Ver 3 or latest. As per latest UL or FM or VDS or LPCB approved/Listed.( Inspection by RDSO )

14

134184

2216721.99

... More
Supply, Installation, Testing & Commissioning of Aspiration (Air Sampling Type) Detection Unit complying to RDSO/SPN/217/2021 Ver 3 or latest. As per latest UL or FM or VDS or LPCB approved/Listed.( Inspection by RDSO )

14

278360

4598513.31

... More
Supply, Installation, Testing & Commissioning of CPVC Pipe for Aspiration Detection System complying to RDSO/SPN/217/2021 Ver 3 or latest and shall be listed/approved by UL or FM or VDS or LPCB or tested with appropriate equivalent standard. ( Inspection by consignee )

190

1614

362017.98

... More
Supply, Installation, Testing & Commissioning of Analogue Addressable loop powered Monitor Module with inbuilt isolator complying to RDSO/SPN/217/2021 Ver 3 or latest. ( Inspection by RDSO)

14

8745

144482.43

... More
Supply, Installation, Testing & Commissioning of Analogue Addressable loop powered Control Module complying to RDSO/SPN/217/2021 Ver 3 or latest. ( Inspection by RDSO)

21

8745

216723.65

... More
Suppy,Installation,Testing & Commissioning of Hooter cum Strobe complying to RDSO/SPN/217/2019 Ver 3 or latest (Inspection by RDSO)

8

7748

73144.33

... More
Supply,Testing & Commissioning of 2C 1.5 sq mm twisted shielded armoured copper cable (Per Meter) with accessories complying to the RDSO/SPN/217/2021 Ver 3 or latest. ( Inspection by RDSO)

900

113

120420.18

... More
Supply,Testing & Commissioning of Isolator Device to isolate te circuit in case of short circuit, complying to the RDSO/SPN/217/2021 Ver 3 or latest. ( Inspection by RDSO)

8

3721

35129.92

... More
Supply,Testing & Commissioning of Auto Telephone Dialler (GSM) to send then pre- 109 recorded message to multiple mobile numbers, prorammed earlier, complying to the RDSO/SPN/217/2021 Ver 3 or latest. ( Inspection by RDSO)

4

9303

43912.47

... More
Fail safe Electronic Time delay unit (Plug in type) to operate 24V DC with only one fixed time setting of 30 / 60 / 120 seconds as per RDSO Specification No. IRS-S-61/2000 with Amendment No.3 or Latest. (Inspection by RDSO) 111

4

3971

18745.95

... More
Supply of cable route marker as per RST/C/203 of FRP. (Inspection by Consignee)

350

202

83797.7

... More
"CENTRALISED EI Installation ,testing & commissioning of EI system complying to RDSO Technical Advisory Note No STS/E/TAN/3012 Ver 2.0 dated 10.08.2016 and Supply, Installation ,testing & commissioning of earthing arrangment for EI as per RDSO/SPN/197/2008 at locations 1 /Gumtis/Cabins/EI Huts/Auto Hut of the Yard, Earthing of EI equipment, relay racks and Power equipment etc to be done with Class A protection, Earthing shall be in the form of Perimetric/Ring Earth conforming to RDSO specification and RDSO technical advisory note for earthing and bonding scheme of EI No. STS/E/TAN/3006 Ver.1 Dt. 02.11.2012 or latest, with earth resistance less than 1 ohm. "

1

564158

665707.38

... More
DISTRIBUTED EI:- Installation ,testing & commissioning of EI system complying to RDSO Technical Advisory Note No STS/E/TAN/3012 Ver 2.0 dated 10.08.2016 and Supply, Installation ,testing & commissioning of earthing arrangment for EI as per RDSO/SPN/197/2008 For Yard with " TWO OC", With Class A protection at two locations/Gumtis/Cabins/EI Huts/Auto Hut of the Yard, Earthing of EI equipment, relay racks and Power equipment etc to be done with Class A protection, Earthing shall be in the form of Perimetric/Ring Earth conforming to RDSO specification and RDSO technical advisory note for earthing and bonding scheme of EI No. STS/E/TAN/3006 Ver.1 Dt. 02.11.2012 or latest, with earth resistance less than 1 ohm. Note: This also includes supply of one no. of composite computer table for keeping 04 VDUs & 02 numbers operator chairs. (c) Termination of indoor /PIJF cables relay room, tag block, CT racks as per approved wiring diagram including alterations/ modifications as required at site , soldering, dressing / lacing with thread / bunching ape/belt/buttons. buttons.(d) The 2 tools/equipments/ materials/ simulations boards required for testing shall be supplied / fabricated including replacement of modules/ cards / LED's /equipments going defective during testing. Necessary power supply boards with required capacity plugs, sockets , surge & lightning protection boxes shall be supplied & installed by the contractor. Note - A, B, C, & D class protection shall be provided for all EI Equipment. This will also covered the earthing & necessary protection of EI Equipment as per RDSO specification of EI system and other requirement and pre commissioning check list of EI system. For Class "A" protection separate ring earthing system shall be provided with effective earth resistance should be less than 1 Ohm. 230V shall be arranged by Railways. In case supplies from Power room, Relay rom are required to be extended, then same shall be extended by the contractor with his own materials such as 1x16 sq. mm wires, cables, lugs, RCC /GI pipe, insulated ladders etc.(e) After ST/LT testing ,Factory Acceptance tests(FAT) & square sheet testing should be fault free while submitting to Railways, otherwise suitable necessary action can be taken by Engineer - In -charge.

1

1449068

1709901.07

... More
Training of Technician/ Engineers/ Senior Engineers in installation, for trouble shooting & repairing, Commissioning, Testing, Repairs Troubleshooting. (Hard copies of training material/ course modules to be given to each participant).

5

89414

527544.43

... More
Installation of Cable Termination Racks Assembly complete including wall supports, 4 scaffolding Disconnecting links/ARA terminal, 96 way tag block with tag block cover & other necessary accessories etc. The work shall be done as per approved plan, extant practice on C. Railways & the instruction of Rly engineer at site.

36

1306

55505.64

... More
Fixing of Q series relay base plate/metal to metal relay mini group and major group base plate, laying, bunching, lacing, dressing & packeting of 60/40 core PVC indoor cable/flexible wire 5 and termination of 60/40 core cable/flexible wire on tagblock/base plate & base plates & soldering. This includes fuse wiring, bus bar looping etc. required for keeping installation ready for circuit wiring work & panel throughing work. The work shall be done as per approved plan, extant practice on C.Rly. & the instruction of Rly. Engineer at site. (UNIT NUMBER = TAG BLOCK) 6 4.00 Numbers 21620.16 86480.64 18.00 102047.16 6

36

626

26596.3

... More
Installation, wiring, testing and commissioning of Data logger complete along with accessories with Contractors own wiring & fixing material as per following configuration. (It includes loading of NETWORKING software and networking of data logger. The requisite communication cable/channel for networking will be arranged by Railway. - 1024 digital & 32 analog inputs

-

-

6

... More
Wiring and charging of Integrated Power Supply System to signaling installation. This includes connection of MF Earth of 1 ohm earth resistance for IPS and power distribution connection to bus bars and relay racks in the room with contractor's own wiring materials and fabrication and fixing 7 of AC/DC power distribution board made on 10mm thick Phenolic hylam sheets or any standard make with connections suitable for 63 A.Wiring to be done considering site requirement , depending upon the load with suitable wires,lugs & glands as per instructions of Engineer-in-charge. The item also includes supply & fixing of ladder along the wall for carrying power supply wires/cables from IPS room to Relay room/power room and potential free contact wiring at Datalogger IDF, etc.

5

31176

183943

... More
Lettering & Numbering of detail and description writing of particulars of terminations & equipments on relay rack, relays, cable termination rack, battery & power equipments, IPS, operating 8 panel, axle counter etc constituting entire system with contractor's own paint and writing material ("Asian/Dulux" make enamel paints to be used). This includes supply and fixing of teflon strips 3mm thick and 25 mm wide for each row of relays and cable terminations. The work shall be done as per extant practice on C.Rly & instruction of Rly engineer at site.

36

368

15652.61

... More
Preparation of cable route plan, cable coreage plan, location particulars, Cable termination rack particulars, cable meggering report, earth resistance particulars, Traction bonding diagram, 1/2 wire count sheet and any other drawing in Autocad in A3/A4 size.The contractor shall initially supply 3 sets of circuits complete for approval of Railways. Railways will return one set to the 9 contractor duly approved with alterations/corrections if any. The contractor shall incorporate Railways alterations/corrections in the tracings without any deviation and submit all tracings complete in all respects to the Railways . This includes submission of final cable route plan as per laid cable duly measured at every 30m clearly indicating distance of laid cable from fixed point of reference & indicating all track crossings and tail cables. This also include designing of cable coreage plan based upon I.P in consultation with engineer-in-charge. - For small/medium yards

2

24049

56757.67

... More
Excavation and Casting of Main signal foundation as per Drg No SK 801 with 10 contractor's own materials including cement and anchor bolts of standard size. The required scaffolding Ferma etc for Casting of foundation will have to be brought by the contractor at his own cost.

73

9149

788124.15

... More
Excavation and Casting of Shunt signal foundation as per Drg No SK 802 with 11 contractor's own materials including cement and anchor bolts of standard size. The required scaffolding Ferma etc for Casting of foundation will have to be brought by the contractor at his own cost.

29

2649

90656.31

... More
Erection of CLS Post with Surface base and signal unit on top or on OFF set Bracket, 12 fixing of front and back staging, ladder and guards, signal name plates/boards if any with contractors own brackets and fixing materials. This also includes erection of auxiliary signals like calling on, shunt signal if any. The work shall be done as per instructions of Rly engineer at site.

73

3490

300647.55

... More
Erection of shunt signal with Surface Base, Post, Signal unit and fixing of No.plates. The work shall be done as per instructions of Rly engineer at site. 14

29

481

16474.88

... More
Fixing of Jn.Route Indication 1-Way/2-Way/3-Way on the top of the signal post.

18

763

16220.99

... More
Fixing of Stop Board, Block section limit Board, goods warning board with contractors own material. The work shall be done as per instruction of Rly engineer at site.

10

553

6528.7

... More
Termination of tail cable on Main signal units and wiring with contractor own material, etc. The work shall be done as per instruction of Rly engineer at site.

73

1096

94432.7

... More
Termination of tail cable on Shunt signal units and wiring with contractor own material, etc. The work shall be done as per instruction of Rly engineer at site.

29

356

12190.19

... More
Installation of ON/OFF aspect LED's in signal including termination of tail cable on 18 signal, wiring, fixing of LED units and testing. The work shall be done as per instruction of Railway Engineer at site.

175

545

112674.66

... More
Supply and fixing of Protective screen of expanded metal 12 SWG of size 1200 x 1500 mm on signals as per standard practice.

10

4319

50968.57

... More
Fabrication and fixing of phenolic laminated/Fibre glass sheet in location box by 20 providing all fixtures as per Railway Drawing including fixing of PVC coated/with PVC pipe covered string rods at the back side for cable support with contractor's own materials. The work shall be done as per drg and arrangement similar to SK 783-1&2. with latest alterations & as per instructions of Rly engineer at site. Single Case

105

2251

278989.35

... More
Fabrication and fixing of phenolic laminated/Fibre glass sheet in location box by 21 providing all fixtures as per Railway Drawing including fixing of PVC coated/with PVC pipe covered string rods at the back side for cable support with contractor's own materials. The work shall be done as per drg and arrangement similar to SK 783-1&2. with latest alterations & as per instructions of Rly engineer at site. Half Case

45

1984

105391.82

... More
Fixing of cutting in relay bases & wiring of relays with Contractors own material obtained from approved sources in location box as per the instuctions of Engineer in charge.

130

566

86861.22

... More
Fixing of ARA Terminals and fuse blocks on phenolic laminated sheets and fixing by stainless steel/brass nuts & bolts.This includes provision of two additional holes on the board on either side for cable conductor entry.

52150

732707

864594.85

... More
Termination of cable cores on ARA terminal/fuse blocks in the apparatus Cases/ cable termination rack.This includes all associated works of pulling out the cable from underground. The work shall be done as per location plans and instructions of Rly engineer at site.

56500

597770

705368.6

... More
Excavation and Casting of Apparatus Case foundation with contractors Anchor bolts, cement, ballast and other materials. The required scaffolding Ferma etc for Casting of foundation will have to be brought by the contractor at his own cost. - Single Case as per Drg No . SK-803

105

9887

1225001.78

... More
Excavation and Casting of Apparatus Case foundation with contractors Anchor bolts, cement, ballast and other materials. The required scaffolding Ferma etc for Casting of foundation will have to be brought by the contractor at his own cost. - Half Case as per Drg No . SK-804

45

9693

514747.68

... More
Erection of Apparatus Cases. This includes filling of location foundations and plastering - Single Case

105

1098

136047.16

... More
Erection of Apparatus Cases. This includes filling of location foundations and plastering - Half Case

45

842

44731.44

... More
Installation of Eqpt. (Relays, resistance, chargers batteries etc.as applicable) & wiring of the same in apparatus Cases as per location diagrams & circuit diagrams, as per Instruction of site incharge and practice - Single Case

105

1497

185567.51

... More
Installation of Eqpt. (Relays, resistance, chargers batteries etc.as applicable) & wiring of the same in apparatus Cases as per location diagrams & circuit diagrams, as per Instruction of site incharge and practice - Half Case

45

1017

54044.12

... More
Installation of earth electrode assenbly as per Drg.No.RE/S&T/SIG/Tender/SK726/85 including earth wire connected through GI wire 8 SWG supported on M.S. flat of size 6mm x 40 mm to earth electrode as per drg. No. CR/S&T/SK-815 for sigg. Equipment such as lever frames, apparatus 31 case, signals, relay racks,block insruments, and etc. as per RE manual. The earth value should be less than 10 Ohms including the lead wire. The value should be measured in presence of Rly. supervisor. It should be documented and painted on earth enclosure made of concrete.( only earth electrode will be supplied by Railway). All other material required for provision of earthing will be brought by the contractor.

245

2528

730885.27

... More
Installation & commissioning of A-Class Lighning protection complete include base plate with base mast & accessories. SPN: NFC-17-102-2011 and as per IS 2309:1989.

4

19122

90255.93

... More
Installation of unit Earth as per RDSO/SPN/197/Ver.I or latest, to construct earthing of 33

50

5290

312130.06

... More
Connecting main earth electrode to BRC using 35 sq.mm copper cable.

750

92

81942.15

... More
Installation of 25 x 6 mm copper tape (bonding ring conductors) mounted on insulated standoffs (1 round) 36

150

207

36748.74

... More
Installation of 300 x 25 x6 mm Cu equipotential Bus Bar.

65

441

33852.31

... More
Installation, wiring, testing & commissioning of Microprocessor baased universal earth leakage detector unit 12 channel AC/DC.

12

7411

104940.18

... More
Erection, Fitting and Rail connection of Track Lead Juntion Box on two 38 supports(M.S.angle) with contractor's fixing material and PVC jacketed wire for track lead connection including angles of size 40 x 40 x 5 mm 1200 mm length. This will include drilling of holes for track lead/side connections on rail. The work shall be carried out as per Drg. No. SK-845 or/& instructions of Rly engineer at site.

370

1305

569911.44

... More
"Provision of bonding with contractor's PVC jacketed wire rope for Track Lead connection. PVC jacketed wire rope should be of Galvanised steel wire rope 6mm dia (6 x 19 stranded 39 wire with steel core of 6 mm dia ) sheathed with PVC 2mm wall thickness, overall thickness being 10mm PVC sheath should be made of type 6 compound as per IS 5831 of 1984 Reaffirmed 2001 and steel wire rope as per IS:2266:2019. Reclaimed or recycled material should not be used. This will include drilling of 7.1mm dia holes in rails (4 Nos) and provision of two jumpers for each bond, clipping of bonds etc. with contractors own materials and tools as per instruction of Rly engineer at site."

370

169

74069.19

... More
Provision of bonding with GI wire 4mm dia ( 8 SWG) for track jumper & fish plate joints bonds. This will include drilling of 7.1mm dia holes in rails (4 Nos) and provision of two jumpers for each bond, clipping of bonds etc. with contractors own tools as per instruction of Rly engineer at site.

1200

160

227239.68

... More
"Installation of Axle counter(Digital)/Central Evaluator, wiring from CT rack to Central evaluator, installation and wiring of indoor & outdoor reset box and wiring the power supply including 41 supply of 2 core shielded cable of required size copper conductor as per IRS S 76/89 or IS 694/1977 as applicable with other accessories. NOTE : installation/programming/configuration/commissioning of Axle counter equipment to be carried out in accordance with latest guidelines issued by Railways/RDSO preferably by Authorised representative of OEM."

11

27340

354874.89

... More
"Installation of EJB and Track devices of Digital Axle Counter including digging of trench, drilling of holes,if required on rail , laying of Doubled walled antirodent corrugated pipe, 42 Medium class from track device to location box and making its terminations. ( DWC pipe made up of High density Polyethylene of 60mm outer dia of suitable length and all other accessories as per site requirement to be supllied by firm.) NOTE : Installation/programming/configuration/commissioning of Axle counter equipment to be carried out in accordance with latest guidelines issued by Railways/RDSO preferably by Authorised representative of OEM."

11

15731

204196.3

... More
Fixing of track devices ( Transmitter coil and receiver coil ) to the rails , fixing of EJB in 43 the location ,connection of track device to EJB using DWC pipe of suitable length and wiring of EJB ,testing and adjustment of transmitter and receiver to obtained required channel level as per standard practices on C.Rly. and instructions of Rly Engineer on site . Per 44 13.00 Detection 2890.19 37572.47 18.00 44335.51 Point (DP)

11

13436

174399.67

... More
Installation, wiring & testing / commissioning of Multi Section Digital Axle Counter's Central Unit/Evaluator/Processor for the section /at station including its associated all indoor equipments, indication panel, monitoring console/interface computer and wiring the same to integrate with the relay circuits including supply of required power cable of multi -strand 10 Sq mm or more from power room to Central Evaluator, 2 core shielded cable of required size copper conductor as per IRS (S) 76/89(Amd.3) or IS 694/2010 with latest amendment as applicable with other accessories as per the instructions of Railway Engineer at site and earthing as per OEM's technical requirement and specifications. This also includes laying & termination of cable if any from Panel Room to Axle Counter room /Relay room in DWC pipe with contractor's material / existing ladder.

-

-

44

... More
Installation, wiring & testing / commissioning of Axle Counter's Reset Box of all types in 45 Cabin/Panel room and wiring the same to integrate with the Axle counter as per the instructions of Railway Engineer at site. This includes laying & termination of cable if any form Panel Room/Axle Counter room /Relay room to Reset Box in DWC pipe / existing ladder.

2

7655

18066.67

... More
Installation, Fixing and wiring of track side Electronic Equipment of Axle counters including its battery & charger (if required), foundation and earthing as per OEM's technical 46 requirement and specification associated Relays in apparatus cases, location huts, relay rooms etc., with contractor's wiring material, termination of tail cables on terminals/fuse blocks. Supply and making Axle counter Parameter History Cards, all activities as per standard practice and technical specifications. Per 47 26.00 Detection 956.92 24879.92 18.00 29358.31

26

16824

516181.8

... More
Supply, fixing & wiring of mismatch panel depcting Indication Panel/VDU layout with contractors own material like LEDs for each track section, flexible wire, connecting terminals, buzzer etc. The work shall be done as per extant practice on C.Rly. & instruction of Rly. Enginer at site.

23

50121

1360292.35

... More
"Fixing of point machine on newly laid turnout o n Wooden/MBC sleepers , fixing of ground connections, adjustment and testing with crank handle operations,Removal of ground 49 connection & point machines duly numbered. This will include fixing of bend pipes with welded frame for cable entry to machine. This will also includes necessary adjustment and smithy work, drilling of holes to tounge rails, fitting of insulation for tounge attachment, gauge plate & stretcher bars, cable termination & wiring if required. The work shall be done as per extant practice on C. Rly & the instruction of Rly engineer at site." (UNIT TURN-OUT= TURN OVER)

46

3526

191434.16

... More
Installation, fixing and wiring of Boxes for Key Lock Relays with contractor's wiring and fixing material.The work shall be done as per extant practice on C. Rly & the instruction of Rly engineer at site.

37

3119

136192.57

... More
"Excavation of cable trench as per cable route plan,1.0 mt. deep and 300mm wide along side the track in normal soil/strata, conforming to distances as per cable route plan and refilling after cable laying. This work includes covering of cable laid in trench by loose soil for a layer of 50mm 51 thickness after clearing of route,bushes etc. It shall be ensured that top of the cables laid is at a depth of 0.8m or more. It if is less, then the width and depth shall be suitably increased and accordingly proportionate payment shall be made. In case depth of trench is not achievable due to site conditions proportionate payment will be made as per procedure. The work shall be done as per the extant practice on Central Railway and instructions of Railway Engineer at site. Drg. No. SK 805"

5050

350

2085650

... More
"Excavation of cable trench as per cable route plan,1.0 mt. deep and 300mm wide along side the track in hard soil, conforming to distances as per cable route plan and refilling after cable laying. This work includes covering of cable laid in trench by loose soil for a layer of 50mm 52 thickness after clearing of route,bushes etc. It shall be ensured that top of the cables laid is at a depth of 0.8m or more. If it is less, then the width and depth shall be suitably increased and accordingly proportionate payment shall be made. In case depth of trench is not achievable due to site conditions proportionate payment will be made as per procedure. The work shall be done as per the extant practice on Central Railway and instructions of Railway Engineer at site. Drg. No. SK 805"

300

583

206498.82

... More
"Cutting of all types of Roads/ platforms (except concrete type) for trenching and 53 excavation to depth of 300mmx300mm wide approx. and refilling after laying of RCC/GI /DWC pipe & to restore them to original condition. The work shall be done as per extant practice on C.Rly & instructions of Rly engineer at site. Drg. No. SK 807" 54 600.00 Metre 69.97 41982.00 18.00 49538.76

110

2916

378583.77

... More
Fixing of GI pipes for crossing the culverts, bridges etc. and concreting of ends with brick masonry at both ends as per the instruction of Rly engineer at site.

-

-

54

... More
Digging of trench 1.0 M deep from rail flange/road level (for LC) and 0.3Mtrs. to 0.6 55 Mtrs wide and back filling after placing of DWC/RCC/GI pipe.(Placing of DWC/RCC/GI pipe covered separately. The ballast disturbed be screened and dressed as required by Engineer-in-charge or his representatives and road tarred immediately. Drg. No. SK 806

300

583

206498.82

... More
Laying of DWC/RCC pipes alongwith collars/RCC Half round pipes in trenches at places of track and road crossings, platform cuttings etc. 57

13000

56

872079

... More
Laying of signalling/Power/Telecom cable of various cores/sizes in trenches.

250

5197

1533238.9

... More
Placing and securing of cable route markers in trenches at the specified interval and at diversions, joints etc along the cable route. The work shall be done as per extant practice on C Railways & the instruction of Rly engineer at site.

350

12

5174.89

... More
Wherever depth of 0.5M cable trench is not feasible, cable shall be protected as under:- Preparation of cement mixture 1:3:6 with contractor's own materials and spreading cement concrete mixture layer of 100 mm thick over the already laid cables in the excavated trench.

110

5329

691775.59

... More
Fixing of modular terminal/fuse blocks alongwith all accessories with provision of fixing 60 holes on hylam sheets/side angles of Loc Box and fixing by galvanised nuts & bolts. This includes fixing of DIN channel alongwith PVC Comb type 'C' channel (size 2 inch x 2 inch) for cable termination on modular terminal. The PVC channel with cover to be supplied by firm as required. The work shall be done as per the instruction of Rly engineer at site.

21150

19

475430.85

... More
Termination of cable cores on ARA terminal / Disconnecting link/fuse blocks, in the 61 Apparatus cases/cable termination rack. This includes all assosiated works of pulling out the cable from under underground. The work shall be done as per location plans and instructions of Rly engineer at site.

51000

7

427278

... More
Painting two coats of synthetic enamel paint over one coat of Red Oxide primer after scrapping and cleaning of the surface wherever necessary with contractor own supply of primer and 62 paints over all outdoor gears including lifting barrier, axlecounter, ground frame, point machine, location boxes, signal post, unit, track circuits etc The work shall be done as per extant practice on C Rly & the instructions of Rly engineer at site. (Paints to be used shall confirm to relevant IS spec.). This includes Lettering / Numbering Termination particulars, equipment names etc. legibly and neatly inside and outside surface of units, boxes etc.- for small stations.

2

23283

54947.97

... More
"Painting of two coats of synthetic enamel paint over one coat of primer on the following after scraping & cleaning surface wherever necessary with contractor' own supply of 63 paints.Wherever required contractor shall apply coating of epoxy paint also as per instructions of site- in-charge.Epoxy paint will be supplied by Railways. NOTE:- The paint and primer should be from M/s Asian paints Co. Ltd.,. The paints will be primer (IS 5660 of 1970) the Aluminium synthetic black enamel (IS 2932 of 1974) brilliant white and yellow Painting two coats of enamel paint over one coat of primer. - Apparatus Case Full Size."

105

435

53951.02

... More
"Painting of two coats of synthetic enamel paint over one coat of primer on the following after scraping & cleaning surface wherever necessary with contractor' own supply of 64 paints.Wherever required contractor shall apply coating of epoxy paint also as per instructions of site- in-charge.Epoxy paint will be supplied by Railways. NOTE:- The paint and primer should be from M/s Asian paints Co. Ltd.,. The paints will be primer (IS 5660 of 1970) the Aluminium synthetic black enamel (IS 2932 of 1974) brilliant white and yellow Painting two coats of enamel paint over one coat of primer. - Apparatus case Half Size."

45

326

17363.17

... More
"Painting of two coats of synthetic enamel paint over one coat of primer on the following after scraping & cleaning surface wherever necessary with contractor' own supply of paints.Wherever required contractor shall apply coating of epoxy paint also as per instructions of site- 65 in-charge.Epoxy paint will be supplied by Railways. NOTE:- The paint and primer should be from M/s Asian paints Co. Ltd.,. The paints will be primer (IS 5660 of 1970) the Aluminium synthetic black enamel (IS 2932 of 1974) brilliant white and yellow Painting two coats of enamel paint over one coat of primer. - Main Signal Post with Signal Units, Surface base and complete fittings as per Central Railways standard practice."

73

756

65203.67

... More
"Painting of two coats of synthetic enamel paint over one coat of primer on the following after scraping & cleaning surface wherever necessary with contractor' own supply of paints.Wherever required contractor shall apply coating of epoxy paint also as per instructions of site- 66 in-charge.Epoxy paint will be supplied by Railways. NOTE:- The paint and primer should be from M/s Asian paints Co. Ltd.,. The paints will be primer (IS 5660 of 1970) the Aluminium synthetic black enamel (IS 2932 of 1974) brilliant white and yellow Painting two coats of enamel paint over one coat of primer. - Shunt signal post with signal unit, surface base as per Central Railway's Standard Practice."

29

180

6182.19

... More
"Painting of two coats of synthetic enamel paint over one coat of primer on the following after scraping & cleaning surface wherever necessary with contractor' own supply of 67 paints.Wherever required contractor shall apply coating of epoxy paint also as per instructions of site- in-charge.Epoxy paint will be supplied by Railways. NOTE:- The paint and primer should be from M/s Asian paints Co. Ltd.,. The paints will be primer (IS 5660 of 1970) the Aluminium synthetic black enamel (IS 2932 of 1974) brilliant white and yellow Painting two coats of enamel paint over one coat of primer. - Track lead Junction Box. (Black enamel outside only)"

370

89

38962.18

... More
"Painting of two coats of synthetic enamel paint over one coat of primer on the following after scraping & cleaning surface wherever necessary with contractor' own supply of paints.Wherever required contractor shall apply coating of epoxy paint also as per instructions of site- 68 in-charge.Epoxy paint will be supplied by Railways. NOTE:- The paint and primer should be from M/s Asian paints Co. Ltd.,. The paints will be primer (IS 5660 of 1970) the Aluminium synthetic black enamel (IS 2932 of 1974) brilliant white and yellow Painting two coats of enamel paint over one coat of primer. - Point Machine with ground connections complete (Point Machine with Black enamel only outside and ground connections with Red Oxide)"

64

156

11801.51

... More
"Painting of two coats of synthetic enamel paint over one coat of primer on the following after scraping & cleaning surface wherever necessary with contractor' own supply of 69 paints.Wherever required contractor shall apply coating of epoxy paint also as per instructions of site- in-charge.Epoxy paint will be supplied by Railways. NOTE:- The paint and primer should be from M/s Asian paints Co. Ltd.,. The paints will be primer (IS 5660 of 1970) the Aluminium synthetic black enamel (IS 2932 of 1974) brilliant white and yellow Painting two coats of enamel paint over one coat of primer. - Axle Counter devices."

24

107

3045.82

... More
Lettering / Numbering of Signals, Point Machine, Track Lead Junction Boxes, Block Joints, Apparatus Cases etc. (each item to be taken as One Unit) This work will be carried out as per the standard practice being followed in Central Railway.

566

56

37828.72

... More
Lettering / Numbering Termination particulars, equipments names etc., legibly and neatly inside location boxes. - Full Case.

105

263

32651.37

... More
Lettering / Numbering Termination particulars, equipments names etc., legibly and neatly inside location boxes. - Half Case.

45

150

7966.59

... More
Installation, testing & commissioning of the 25 W VHF system including the erection of Mast, Antenna, charging of the battery with all Contractor's materials.

2

8626

20358.3

... More
Releasing of Existing Panel, Power Equipments,relays and relay racks, CT racks, 74 Batteries, Block Instts., Ground frame/s, Location Boxes, TLJBs, Signal Posts, Signal Units, Equipment inside the location boxes, Lifting Barrier , rodding runs,etc as applicable including the breaking of foundation etc. as per the instructions of Rly Engineer at site & their transportation to nominated depot.

2

40945

96631.07

... More
Releasing of cables from old location boxes and taking it into new location boxes. This includes excavating the earth to release the cables from old location box for taking it into new location. This also includes releasing the old location box and bringing it to nearest station / central cabin. 76 5150.00 Metre 2610.46 13443869.00 18.00 15863765.42 76

15

2197

38890.62

... More
Horizontal boring of cable duct of minimum 2.0 Mtr. depth alongwith laying of 120mm HDPE pipe for track crossing with minimum depth reckoned from the bottom of the rail/road crossing with minimum depth reckoned from ground level. The work shall be done as per extant practice & instructions of site Engineer. Prepration of site for Horizondal boring shall be carried out in presence of Railway Representative. HDPE will be supplied by Railways. Note:- Contractor shall provide all material required for boring and adequate nos. of labours for proper laying of cables into the bore. Cable shall be laid cautiously so that it should not get damage due to rough handling & pressure on cable.

-

-

76

... More
Wiring, Fixing & commissioning of modular of fuse 0.6 to 4 Amp rating alarm system having change over arrangement and potential free contact writing at Datalogger IDF Etc as per instruction of Railway Engineer (Module of 32 nos fuses).

102

65980

77857.27

... More
Wiring, Fixing & commissioning of modular of fuse 4 to 10 Amp rating alarm system having change over arrangement and potential free contact writing at Datalogger IDF Etc as per instruction of Railway Engineer (Module of 24 nos fuses).

6

3874

4572.48

... More
"Preparation of final ammonia prints of diagrams in A-3 size after tracings are approved by Railways, in four sets for final submission with one set of diagram in transparent 79 polythene bag/lamination (only two sheets shall be placed in one polythene bag/laminated each). Every set shall be set in a plastic folder of A3 size and of good quality. The final approved tracings will be handed over to contractor by railway for this purpose and contractor will return back the same after taking out the prints for stations having less than 20 routes. - For major yards and stations having more than 200 routes"

2

55522

131033.1

... More
"Installation & commissioning of Block Proving with Digital Axle Counter as per RDSO specification no. IRS: S-105/2012 using UFSBI & Block panel for Single/Double Line operation. (Unit-one pair Qty. is 1 set)."

4

72794

343590.7

... More
Installation, Testing and commissioning of complete block Equipment., Universal Fail Safe Block Interface (Multiplexer), wiring in relay room, panel room for single line operation system as per technical specification. (UFSBI equipment will be supplied by Railway).

4

19476

91930.45

... More
Charging of 2V Lead Acid Batteries with contractors own battery grade sulphuric acid 82 and distilled water with minimum two charge - discharge cycles, installation of charged batteries in groups & their connection & wiring. The work shall be done as per extant practice of C.Rly & instruction of Engineer-in-charge.Detailed measurements of initial charging shall be recorded jointly by contractor & Rly's site-in-charge. (Unit Numbers = Per 100 VAH)

360

75

32229.58

... More
Installation, testing and commissioning of Earthing arrangement for EI as per RDSO/SPN/197/2008 or latest. Earthing shall be in the form of ring earth confirming to RDSO Drawing 3 issued as per Rly. Board letter's No. 2010/SIG/SGF/EI (Ansaldo) dt 26.06.11 and RDSO Technical Advisory note for Earthing and Bonding scheme of EI No. STS/E/TAN/3006 Ver. 1 made dt 02.11.2012 or latest.. Note - this will also coverer the earthing & necessary protection of EI Equipment, as per detail given in the scope of work and pre commissioning check list of EI system. The earthing schematic shall be got approved from RDSO/ competent authority .

2

99157

198314.18

... More
Maintenance and supervision of EI system installed EI items of SCH C I (for NGN and MWD Station) for one year as per details given in Special Condition of Contract, Technical requirement & SEM. Unit Year= EI/Year

-

-

4

... More
Fabriction finishing erection of VDU wooden console for fixing of VDU (wall mounted type, reset box, block instrument & other accessories related to operation of train for station masteras 5 per instruction of site engineer. NOTE: Semi decagon shape table of require size of hight suitable for comfortable operation of VDU fitted with open/cover shelf/drawer arrangment for fixing of operating VDU / telephone, terminal box/reset box/DLBI/SLBI/UFSBI & other arrangment of any other requirment of S&T/Optg Dept., all the materials and sundry item, for fabriction of console are to be supplied by contractor. (Inspection by Consignee)

2

82902

165804

... More
Supply of Steel Cupboard (plain storwel) size 6' X 3' Godrej Make (Inspection by Consignee)

5

13127

65639.75

... More
Supply of Panel operator/Relay room Chair model PCH - 7001 (Godrej) (Inspection by Consignee)

12

12518

150225.12

... More
Supply of Panel operator/Relay room record table model T - 102 (Godrej) (Inspection by Consignee) 4

6

14757

88544.88

... More
Supply of Chair model PCH - 7003 (Godrej) (Inspection by Consignee)

5

8977

44889.85

... More
Supply of Steel stools Godrej make model No ST2 or equivelant of same make (Inspection by Consignee)

6

2072

12436.98

... More
Supply & installation of 42 U Rack with FAN, make HCL, APW, Rittal, President or similar. (Inspection by Consignee)

3

51511

154534.44

... More
Preparation and supply of interlocking plan on the basis of approved engineering plan. 7 The contractor shall initially supply one print of IP duly signed by the designer and submit for approval of Railway. Railway will return one set of SIP duly approved with alterations/correct if any. The contractor after due corrections will submit 04 prints of SIP for approval, if any, the contractor will submit final tracing, CD and foour copies of IP to the Railway. Up to 50 Route

1

23285

23285.34

... More
Preparation and supply of interlocking plan on the basis of approved engineering plan. 8 The contractor shall initially supply one print of IP duly signed by the designer and submit for approval of Railway. Railway will return one set of SIP duly approved with alterations/correct if any. The contractor after due corrections will submit 04 prints of SIP for approval, if any, the contractor will submit final tracing, CD and foour copies of IP to the Railway. 51 Route to 75 Route

1

32987

32987.57

... More
Arranging labour as and when required by the Engineer incharge, for various works under SSE/Sig/Const/BSL, with contractor's T&P, equipments, etc. as per specifications, special conditions and detailed scope of work as furnished in the tender and as directed by the Engineer 9 incharge. Note ; For the paying quantity, a total of 12 hours duty of a man will be counted as one manday and nothing extra shall be payable for night working. However, in a day, total working hours shall not exceed 12 hours. In case, working hours exceed 12 hours, separate manday shall be counted. Note :- Location shall be identified in advance.100% test check in advance to be done by concerned ADSTE/Const/BSL as a proof of identification and got signed by him.

2000

585

1170400

... More
Providing road breaker /concrete breaker with compressor and jack hammer for railway work such as cutting and dismentilling of road concrete /Bricks pucca structure (RCC/Steel section) including contractor's fuel, driver and all other charges completed as directed by Engg in charge.

70

1483

103845

... More
Supply of Tool Kit for maintainance of Multi Section Digital Axle Counte (MSDAC) 11 consists of service test panel including Meter for testing of track equipments as per manufacturingspecifications. (Tool kit should be suitable for maintainance of MSDAC supplied) (Inspection by Consignee) a Torque wrench with reversible ratchet with 19 mmsocket b Screw driver small No.22 (Taparia) - 1 NO. c Nut driver 13mm - 1No. d Fix spanner 16x17 - 1No. e Fix spanner 10x11 - 1No. f Fix spanner 8x9 - 1No. g Nose plier 1430 (Taparia) - 1No. h Nose plier (Taparia mini)- 1No. i IC cutter MT 10 Multitech - 1No. j Wire stripper 15OP Multitech - 1 No. k Combination plier (Taparia) - 1NO. l Screw driver (Taparia) size-T 20L - 1 No. m Soldering Iron - 1No. n Soldering wire - 1No. o Tool Box with Lock & key p Dummy Wheel q Card Puller r Marking Jig-52 Kg/60Kg s Measuring Card t Fluke Meter 289

2

190868

381737.74

... More
Supply of Earth Resistance tester dual range 10/100 ohms, digital display with complete earth testing kit. Motwane DET20 or similar (Inspection by Consignee)

5

6825

34125

... More
Supply of digital multimeter with AC/DC clamp, three & three forth digit model Meco 3690 Auto or similar other make (Inspection by Consignee)

5

3900

19500

... More
Supply of Insulation resistance tester with3-3/4 digital display suitable for 100 V Kusum Mecco KM01 or Rish Insu MIT 30 (Inspection by Consignee)

5

8482

42412.5

... More
Supply of True RMS Multimeter Fluke Make model 289 or similar. (Inspection by Consignee)

5

78000

390000

... More
Supply of Digital earth clamp tester for measurement of earth resistance. Make - Motwane Model DECT-3/ FLUKE Model-1630/ MECO Model-4680 B/ KYORITSU Model-4200. Generalized Specilication for Portable Drtal Earth Clamp Meter is as under:- SN. Parameters Characteristics l.Resistance measurement range--O.Ol Ohm to l2OO Ohm. 2.Current Measurement Range--0 to 2O A, 3.Display--4 digrts 9999 count LCD, 4.Resolution Range--O.OO1 Ohm to 30 Ohm,5.Accuracy-+/-( I percent+o.ol Ohmlto +/-125 percent +30 Ohml,6.Conductor size -- 23mm approx / 35mm 16 approx,T.Jaw size- 65mm x 32mm, 8.Instruction manual-To be provided, 9.Computer interface - RS 232,US8, lO.Environmental - Working temperature: O deg to 50 deg, Humidity less than 85 percent RH. ll.Memory Storage Facility-99 records 9[illoop resistance with no inductive, external magnetic field-- <50 A/m,9[ii]External Electric Field- < L Y /m, lo.Power Source-6 v DC l4x1.S V AA alkaline batteryl,l2.Single measurement / Sampling time- 0.5 second, l3.Sound and light enunciator - Beep sound, Flashing Symbol, AL Key to turn on - off and setting the sound and light alarm, l4.Over [,oad Indicator- -"OL" on display, l5.Overload Protection - itOA [Continuous],200A[5 sec], 16.Low battery indication- Display Symbol, 1 7. Range Selection-Auto, 18,Single Measurement time-O.S sec (Inspection by Consignee)

2

55264

110528.14

... More
Supply of DC-module along with Dc-Dc converter 110 v to 24-32 V/5 & 12-28 V/5 Amp or any suitable for IPS available at per site requirement 50% each(12-28 & 24-32) (Inspection by RDSO).

20

15283

305667.2

... More
Supply of DC-module along with Dc-Dc converter 110 v to 24-40 V/5Amp (for Axle Counter) or any suitable for IPS available (Inspection by RDSO).

20

15283

305667.2

... More
Fixing of DC-DC converter module and change in internal woring of IPS to suit DC-DC converter ( Note : Unit to treated as DC-DC converter)

40

6457

258302

... More
Installation, Testing and commissioning of Solid state Block proving by Axle Counter for 20 single line. This includes following items:1) Installation, Testing & Commissioning of Station Master's Block Panel - 02 Nos. 2) Installation, Testing & Commssioning of Micropercessor based SSBPAC[D] - 02 Nos. 3) Installation, Testing & Commissioning of Automatic Media changover of modems, Leased line Modem etc. as per instruction of site engineer.

4

87516

350064

... More
Supply & Installation of Modular Power Supply Arrangement for VDU (42"-85") and Industrial PC (Embedded PC) with Input and Output Redundancy Arrangement and Hot Plugable Modules. 01. Insput O-Ring Diod Module with Potential Free-1 No contacts Per

6

250250

1501500



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.