Central Railway Tender
... More
Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.
Central Railway Tender
Ireps
Opening Date29 Jan 2025
Closing Date27 Feb 2025
Tender Amount₹ 6,54,94,983.45
AI Insights
Technical
Technical
Financial
Technical Capacity
... View More
The required prior work experience for the bidder includes successfully completing or substantially completing any one of the following categories of work(s) during the last 7 years: (i) Three similar works each costing not less than the amount equal to 30% of advertised value of each component of tender, (ii) Two similar works each costing not less than the amount equal to 40% of advertised value of each component of tender, (iii) One similar work each costing not less than the amount equal to 60% of advertised value of each component of tender. For a Joint Venture (JV), each non-lead member must have satisfactorily completed or substantially completed during the last 7 years, one similar single work for a minimum of 1/3 (approximately 33.33%) of the advertised value of the tender. In case of works with composite components, each non-lead member of the JV must have technical capacity of minimum 1/3 (approximately 33.33%) of the cost of any component of work mentioned in the technical eligibility criteria.
Costs
EMD
₹ 4,77,500Document Cost
Refer DocumentsTender Fee
Refer Documents
Summary
Replacement Of Old Aged Quad And Ofc Cable In Lonavla-pune-daund Section Of Pune Division.
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
CR-PA-SNT-WKS-T-2025-03-PUNE DIVISION-S AND T/CENTRAL RLYTender No
CR-PA-SNT-WKS-T-2025-03Tender Authority
Central Railway ViewPurchaser Address
-Website
http://ireps.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
... More
Supply of Thermo shrink Cable Jointing kit (Reinforced) TSF-2 type generally 3 conforming to RDSO specification RDSO/SPN/TC/57/2015 Rev 1 with modified kit contents as per CSTE's Specification No.CR/SPN/TC/57(A)/2015 Dt. 06.01.2015 (Table-A) to be suitable for jointing both 10/20/50 pair PIJF and 4/6 Quad cables along with sub-kit (Table-B) for armour continuity. (Inspection by Consignee).
70
2991
209437.9
... More
Laying of signalling/Power/Telecom cable of various cores/sizes in trenches.
90
5197
467767.8
... More
Wherever depth of 0.5M cable trench is not feasible, cable shall be protected as under:- Preparation of cement mixture 1:3:6 with contractor's own materials and spreading cement concrete mixture layer of 100 mm thick over the already laid cables in the excavated trench.
120
5329
639546
... More
Preparation of final bulit up cable laid plan on auto cad for the section. This includes supply of necessary documents ontracing paper along withfive prints of cable routeplan, jointing schedule, cable hut wiring diagram, emergency socket, manholes etc. The contractor shall also do the preparation of cable route plan, cable corage plan, location particulars, cable termination, cable 2 meggering report, earth resistance particulars, and any other drawing in AutoCAD in A3/A4 size.The contractor shall essentially supply two set of cable route plan complete for approval of Railway. Railway will return one set to contractor duly approved with alteration, correction if any. Contractor shall incorporate Railway altereation/correction in the tracing without any deviation and submit all tracings completed in all respect to the Railway. This include submission of final cable route plan ( Five copies ) as per laid cable duly measured at every 30meters clearly indicating distance of laid cable from fixed point of reference and indicating all track crossing and joint location.
70
1664
116484.2
... More
Supply and installation of RFID based Electronic cable/ pipe marker 22.5 cms dia 1.5m depth range, 10 Digit Hexadecimal ID code 101.4khz frequency. Make: Stanlay, 3M or eqivalent. Inspection -Supply by Rites, Execution by Consignee.
400
3404
1361880
... More
Supply and Placing of Polyolefin Cable channel of size, Width 240/340 mm, Height 8 155/230 internal/external, length 1 m produced of polyolefin with Fire protection class k-1 in accordance with DIN-53438 Part II for laying Signalling/Telecom cables, channel attachable to each other with male-female swallow tail connectors and having suitable detachable cover. Inspection - Supply by Rites, Execution by Consignee.
11000
3201
35218370
... More
Excavation of cable trench as per cable route plan,1.0 mt. deep and 300mm wide along side the track in hard soil, conforming to distances as per cable route plan and refilling after cable laying. This work includes covering of cable laid in trench by loose soil for a layer of 50mm 2 thickness after clearing of route, bushes etc. It shall be ensured that top of the cables laid is at a depth of 0.8m or more. If it is less, then the width and depth shall be suitably increased and accordingly proportionate payment shall be made. In case depth of trench is not achievable due to site conditions proportionate payment will be made as per procedure. The work shall be done as per the extant practice on Central Railway and instructions of Railway Engineer at site.
6000
583
3499980
... More
Supply of HDPE Telecom Duct, solid permanently lubricated as per RDSO specification RDSO/SPN/TC/45/2013 Rev.2.0 or latest in the roll of 1000 mtrs. (Inspection by RDSO).
130
73053
9496900.4
... More
Laying of GI pipes in on bridges/culverts/concrete drawin/mountain ridges etc. with 8 suitable GI bend shall be provided where there is turning of pipe as per the instruction of Site engineer. GI clamps at every 2m as shown in the drawing to be fixed. Suitable holes to be made in the pipe before laying as per the instruction of the site engineer 10mm dia.
500
143
71770
... More
Blowing/Drawing of OFC cable in HDPE/DWC duct and protective work, as per direction of site engineer.
130
13042
1695482.1
... More
Laying of DWC/RCC pipes alongwith collars/RCC Half round pipes in trenches at places of track and road crossings, platform cuttings etc. 6
500
56
28425
... More
Horizontal boring of cable duct of minimum 2.0 Mtr. depth alongwith laying of 120mm HDPE pipe for track crossing with minimum depth reckoned from the bottom of the rail/road crossing with minimum depth reckoned from ground level. The work shall be done as per extant practice & 11 instructions of site Engineer. Prepration of site for Horizondal boring shall be carried out in presence of Railway Representative. HDPE will be supplied by Railways. Note:- Contractor shall provide all material required for boring and adequate nos. of labours for proper laying of cables into the bore. Cable shall be laid cautiously so that it should not get damage due to rough handling & pressure on cable. 12
1000
2610
2610460
... More
Making of Thermoshrink straighht through/derivation/ transformer /PIJF cable joint for underground jelly filled cable 6quad/4quad/20 pair, 10 pair etc. PIJF cable as per the instruction of Rly engineer at site.
70
1516
106173.2
... More
Supply and installation of RFID marker locator, 8000 marker records, built in GPS module, 1.5m depth range 4x20 digits LCD display with all accessories and bag to carry. Make: Stanlay, 3M or eqivalent. Inspection -Supply by Rites, Execution by Consignee.
1
412147
412147.65
... More
Cutting of rock using hand compressor & making chase as per cable route plan ofdepth ranging from 0. 4 m to 0. 2 m deep, 300 mm wide along the side of track and restoring it to the original shape.
500
1510
755160
... More
Excavation of cable trench as per cable route plan,1.0 mt. deep and 300mm wide along side the track in normal soil/strata, conforming to distances as per cable route plan and refilling after cable laying. This work includes covering of cable laid in trench by loose soil for a layer of 50mm 1 thickness after clearing of route, bushes etc. It shall be ensured that top of the cables laid is at a depth of 0.8m or more. It if is less, then the width and depth shall be suitably increased and accordingly proportionate payment shall be made. In case depth of trench is not achievable due to site conditions proportionate payment will be made as per procedure. The work shall be done as per the extant practice on Central Railway and instructions of Railway Engineer at site.
12000
350
4200000
... More
Supply of DWC HDPE pipe with one snap fit coupler and 'O' ring fire resistant, anti rodent, in 6 meter length of size 120 mm outer dia as per RDSO/SPN/204/2011 Ver. 1.1 with Amd.1 or latest. (Inspection by Consignee).
500
321
160715
... More
Splicing/ dropping/termination of each fiber/pigtail in LIU/IO box/terminal joint through fusion splicing for termination of OFC cables. The fibers terminated shall be tested and test report (hard copy and soft copy) shall be submitted to the Railways site in-charge for records. each fiber shall be properly marked with necessary ferrules/tags, as per following specification: i) The optical fibre cables shall be entered in to the rack through cable entry and using the cable guides. ii) The loosened ends of the fibres and pigtails shall be properly prepared for termination in to the already 5 fixed LIU. iii) Each of the fibre shall be spliced with a pigtail by the method of fusion splicing using a Fusion Splicing Machine of standard reputed make. The splicing shall be done carefully by a skillful person. iv) The splices shall be carefully placed and well secured in the splice trays of the LIU. v) Each fiber / pigtail shall be properly marked with necessary ferrules/tags. vi) The extra length of the fibers / pigtails shall be coiled and placed and secured with cable ties. vii) The optical connectors of the pigtails shall be placed into the patch panel as per the numbering of fibers. viii) All of the terminated fibers shall be tested with OTDR and test report (Hard copy and Soft copy) shall be submitted to the Railways site In-charge for records.
1920
133
256665.6
... More
Laying of HDPE duct in trench and its protective work as per direction of site engineer.
130
6137
797936.1
... More
Laying of GI pipes inside the excavated trench in rocky area /less depth area as per 9 instructioin of Site engineer. GI clamps at every 2m as shown in the drawing to be fixed. Suitable GI Bend/Coupling and holes to be made in the pipe before laying as per the instruction of the site engineer.
200
73
14642
... More
Digging of trench 1.0 M deep from rail flange/road level (for LC) and 0.3Mtrs. to 0.6 4 Mtrs wide and back filling after placing of DWC/RCC/GI pipe.(Placing of DWC/RCC/GI pipe coverd separately. The ballast disturbed be screened and dressed as required by Engineer-in-charge or his representatives and road tarred immediately.
500
583
291665
Evaluation Notes How It Works ?