Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.

Central Railway - CR Tender

Works
Telecommunication Services
Ireps
Opening Date20 Jan 2025
Closing Soon17 Feb 2025
Tender Amount₹ 24,27,57,665.37 
Notes
Download

Costs

Summary

Supply, Installation, Testing & Commissioning Of Indoor Signalling Equipment Including Distributed Type Electronic Interlocking At Kalyan Goods Yard

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
"Modification in existing EI system as per latest TAN, it includes :- Design and modification in existing interface and interlocking circuit of EI system, including modification in VDU,CCIP,MT,Data logger, EI, Relay rack complete wiring conforming to RDSO specification, as per technical requirement & tentative approved signalling plan/diagrams. Required hardware will be 4 provided by railways except the wiring, material (i.e. connectors, interconnecting cable/wires, fuses etc.). The work includes supply of modified ST/LT, interface and logic circuit, CCIP/VDU diagram etc. to suit the approved interlocking plan. It also includes modification in data logger/MT, carrying out FAT, SAT jointly with railways and satisfactory commissioning of the modified EI with full complements as per approved IP and central railway practices. All Plans and wiring diagrams shall be prepared on AUTOCAD and supplied in both soft copy and hard copies(6 sets). Alteration involving modification in more than 11 routes upto 20 routes (Inspection by Consignee)"

2

3060830

6121660.9

... More
"Supply of Relay Rack Assembly complete with scaffolding, fixtures and accessories 5 including MS Bars for fixing of relay plug board, string rods, fuse strips with bracket, 11 Way Bus Bars with cover and mounting brackets, runway for cable/wires, frame, base assembly etc. Siemens type & as per extant practice on C. Rly. Typical part list as per Annexure-II and Rack arrangement as per Sketch no SK-727 and Rack plan as approved by Engineer in charge. (Inspection by Consignee)"

30

39537

1186114.8

... More
"Supply of Data logger for monitoring status of important relays, complete with Processor Module to monitor following inputs as per spec. RDSO/SPN/99/2006 Spec. No.: IRS-S-99/2006 (Amdt-3) with latest amendments including power supply of adequate capacity, battery and fault 6 diagnostic software for failure analysis. Complete data logger & Processor Module(computer) as per Annexure-IV shall be placed in President rack of suitable size to be supplied. This also includes supply of one no composite computer & printer table (work station table- Gorej/Durian/Transteel) for keeping Processor module and one no Godrej/Durian/Transteel make operator chair. 2560 digital and 32 analog inputs (Inspection by RDSO)" 7

5

1237389

6186948.7

... More
"Failure analysis software for 2560 digital inputs (Inspection by Consignee)"

5

115214

576074.3

... More
"Supply of PVC flexible copper cable single core multistrand 1 x 10 Sq.mm (80 8 conductor each diameter 0.40 +/- 0.01) as per IS 694/2010 with latest amendment if any.with insulation thickness of 1.0mm nominal conductor resistance 1.91 ohms/Km and test parameters are as per IRS (S)76/89 (Amd.3). (Inspection by Consignee)"

8

157986

1263891.36

... More
"Supply of PVC flexible copper cable single core multistrand 1 x 16 Sq.mm (126 conductor each diameter 0.40 +/- 0.01) as per IS 2465/1984 & IS:694/2010 with latest amendment if any with insulation thickness of 1.0mm nominal conductor resistance 1.121 ohms/Km and test parameters are as per IRS (S)76/89 (Amd.3). (Inspection by Consignee)"

8

235119

1880957.6

... More
"Supply of PVC flexible copper cable single core multistrand 1 x 25 Sq.mm (196 10 conductor each diameter 0.40 +/- 0.01) as per IS 2465/1984 & IS:694/2010 with latest amendment if any with insulation thickness of 1.2mm nominal conductor resistance 0.780 ohms/Km and test parameters are as per IRS (S)76/89 (Amd.3). (Inspection by Consignee)"

8

365362

2922899.6

... More
"Supply of wire 16/0.2 (Blue, Red, Grey, yellow, Brown, Black, White as per site engineer instruction) finolex/polycab/delton make. IRS S-76/89 (Amd.3), BS: 4808 Part-2. Wire to be procured from RDSO approved vender. (Inspection by Consignee)"

8

7218

57748.72

... More
"Supply of Program switches, snap action, base mounting type along with cover and mounting bracket 63A-7 pole 3 position Siemens (3 LAO-63/7Y) / L&T/HAVELLS type. Drg. No. RST.C.106 (Inspection by Consignee)"

80

10660

852826.4

... More
"Supply of Transformer 230V/110V-130V Single Phase 2 KVA as per spec. IRS S-72/88 (Amd.2) with latest amendments. (Inspection by RDSO)"

30

12532

375988.2

... More
"Supply of Track Feed Transformer 230V/110V-130V Single Phase 3 KVA single phase as per spec. IRS S-72/88 (Amd.2) with latest amendments. (Inspection by RDSO)"

30

15458

463756.8

... More
"Supply of Battery Charger self regulating floor mounting type with 230 V AC single phase input and output 60 V DC, 20A as per spec. IRS.S.86/2000 (Amd.4) with latest amendments. (Inspection by RDSO)"

15

59351

890276.85

... More
"Supply of Battery Charger self regulating floor mounting type with 230 V AC single phase input and output 110 V DC, 20A as per spec. IRS.S.86/2000 (Amd.4) with latest amendments. (Inspection by RDSO)"

15

107649

1614735.75

... More
"Supply of Battery Charger self regulating floor mounting type with 230 V AC single phase input and output 24 V DC, 20A as per spec. IRS.S.86/2000 (Amd.4) with latest amendments. (Inspection by RDSO)"

15

42362

635438.7

... More
"Supply of Rubber Mat 5mm thick for use in signalling installation. (Inspection by Consignee)"

1200

149

179592

... More
"Supply of Low Tension Power Distribution Panel suitable for automatic changeover between 3 in coming supplies of 3 phase having manual bypass arrangement along with inbuilt 19 distribution of power supplies suitable for RRI/PI installations.The panel made up of 14 SWG powder coated sheet shall consist of power contactors, aux. contactors, voltage sensing relays, fuses, MCBs, timers, meters, supply indicators and switches of approved make of suitabe rating.General arrangement & scheme to be approved by Engineer incharge. R-ST-11796/1-5 with latest amendments (150A/250A) DRG NO. SK-870 (Inspection by Consignee)"

5

495588

2477941.7

... More
"Supply of QNA1-K AC immunised relay, 8F-8B, 24VDC along with plug board, retaining clip and connectors conforming to BRS:931A & RDSO letter no.STs/E/Relays/ UEA/PI dated 30.05.97 Annexure-II IRS:S60,IRS:S34 & IRS:S23. (Inspection by RDSO)"

70

4736

331587.9

... More
"Supply of QNA1 AC immunised relay, 8F-8B, 24 VDC along with plug board, retaining clip and connectors confirming to BRS : 931A, IRS:S60, IRS:S34 & IRS:S23 (Inspection by RDSO)"

350

4438

1553629

... More
"Supply of QN1 Non AC immunised neutral relay, 8F-8B, 24 VDC along with plug board, retaining clip and connectors confirming to BRS : 930, IRS:S60, IRS:S34 & IRS:S23 (Inspection by RDSO)"

550

4644

2554299

... More
"Supply of QNN1 Twin neutral line relays, 24 VDC 4F-4B/5F-3B/6F-2B contacts, complete with plug board, retaining clip and connectors BRS : 960. (Inspection by RDSO)"

110

7470

821723.1

... More
"Supply of QSPA1 relay, 24VDC, slow to pick up, 8F-4B, along with plug board, retaining clip and connectors conforming to BRS:933A, IRS : S60, IRS:S34 & IRS:S23 (Inspection by RDSO)"

250

4944

1236180

... More
"Supply of Universal LED Lamp proving relay QECX61 relay, 4F-4B,AC conforming to BRS:941A STS/E/RELAYS/AC LIT LED SIGNAL/09-2002, Amdt.-1 (FOR ALL ASPECT ECR FOR AC LED SIGNAL) (Inspection by RDSO)"

260

4170

1084439.2

... More
"Supply of QCJ1 neutral thermal time Element Relay, 24V DC, 2F-1B contacts complete with plugboard retaining clip & connectors BRS:937A (Inspection by RDSO)"

15

6425

96388.5

... More
"Supply of QBCA1 AC immunised relay, 2FHD 4F-4B,24VDC along with plug board, retaining clip and connectors conforming to BRS:943 POINT CONTACTOR RELAY and IRS S46. & firms specification. (Inspection by RDSO)"

130

5458

709543.9

... More
"Supply of QL1 LATCH relay, 11F-4B or 8F-6B along with plug board, retaining clip and connectors conforming to BRB:935A. (Inspection by RDSO)"

130

5458

709543.9

... More
"Supply of QNNA1- AC immunised relay, 4F-4B,24VDC along with plug board, retaining clip and connectors conforming to BRS:960, IRS:S60, IRS:S34 & IRS:S23. (Inspection by RDSO)"

110

5795

637518.2

... More
"Supply of Key Lock Relay working on 24V DC, AC immunized with different ward combinations (Three ward plates to be supplied with each relay). RDSO/SPN/219/ 2016 Version 1.0 d 1. (Inspection by RDSO)"

80

7521

601752.8

... More
"Supply of Fail Safe Electronic Flasher Device 24V DC or 60V DC as per RDSO spec No.:RDSO/SPN/173/2002 amendment 2 or latest. (Inspection by RDSO)"

15

20121

301815.15

... More
"Supply of Block filter unit as per IRS:S-68/89 and Block bell equipment as per IRS:TC- 44/88 (Amd.1). (Inspection by Consignee)"

4

29199

116797.64

... More
"Supply of Block Bell equipment as per RDSO Drg.No. TCA 15080 and Specn. No. IRS- TC-44/88 (Amd.1) with amendment No.1 Voltage 24 V DC. (Inspection by Consignee)"

4

4238

16952.52

... More
"Supply of Wooden block counter of size 700mm x 700mm W X 900mm H made of teak 34 wood frame and 12mm thick water proof ply with formica finish on top and all four sides having two compartment inside and two doors on opposite sides as per drg no. RST/C/110 (Inspection by Consignee)"

4

16648

66592.32

... More
"Supply of Desk type Electronic Magneto Telephone as per spec No IRS TC-79/2000 (Amd.4) or with latest amendments. (Inspection by Consignee)"

25

3782

94573.5

... More
"Supply of Test Board & Circuit progress board for relay room as per Drg No RST/C/105 A&B. (Inspection by Consignee)"

5

14067

70335.45

... More
"Resin cored wire as per specification No. IS:1921-1975 with Alloying element percentage as 63% SN (Tin) and / 37% Pb (Lead) with percentage of various impurities not exceeding 37 the values Sb (Antimony) 0.2% maximum , Cu (Copper) 0.1% maximum, As (Arsenic) 0.05% maximum, Fe (Iron) 0.02% maximum & other impurities mainly Al, Zn & Cd shall be limited. The flux shall be free from corrosive action as per clause 5.2 & flux percentage may be used as per requirement. (Inspection by Consignee)" 38

30

1402

42086.7

... More
"Lacing thread rolls, black, wax coated (100 mtrs). (Inspection by Consignee)"

200

74

14818

... More
"Fabrication and supply of Board made of White sunmica sheet over 12 mm thick 39 particle/laminated/ wooden board covered with 5 mm thick perspex transparent sheet in aluminium/ steel frame and Painting of SWR/Track insulation plan etc. (Inspection by Consignee)" (Number= Per Square Mtr)

11

8415

92571.82

... More
"Design, fabrication and supply of Fuse Auto Changeover System for 32 Nos. of 40 external non-deteriorating type fuses or 'G' type fuses from 0.6A Amp to 4A Amp capacities used in signalling circuits. System shall have 8 cards with monitoring arrangement of 4 fuses in one card. As per RDSO Spec. RDSO/SPN/209/2012 Ver.2.0 or latest amendment if any. (Inspection by RDSO)" (Number = No. of Modules)

80

29971

2397716.8

... More
"Design, fabrication and supply of Fuse Auto Changeover System for 24 Nos. of 41 external non-deteriorating type or 'G' type fuses from 4 A to 10 Amp capacities generally used for point operaton circuits. System shall have 6 cards with monitoring of 4 fuses in one card. As per RDSO Spec. RDSO/SPN/209/2012 Ver.2.0 or latest amendment if any. (Inspection by RDSO)" (Number = No. of Modules)

50

45374

2268749.5

... More
"Design, fabrication and supply of Fuse Alarm System for monitoring Location fuses [HRC type] of various types with automatic changeover facility along with Audio & Visual indications as per technical specifications given in Annexure. (Inspection by Consignee)" (Number = Per fuse)

30

1766

52990.5

... More
"Supply of Modular terminal block of 2.5 sq.mm 2 IN 2 OUT type disconnect type 43 terminal along with as per RDSO/SPN/189/2004 Rev 3.0. The current capacity of 16 Amps and more. The terminal should have marking at centre to view description from front. Material to be procured from RDSO approved firms only. (Inspection by Consignee)" 44

8000

128

1030960

... More
"Supply of DIN Channel for the terminals 1 Mtrs each. (Inspection by Consignee)" 45

800

238

190784

... More
"Supply of End plates for modular terminal block. (Inspection by Consignee)" 46

800

25

20592

... More
"Supply of End Clamp for modular terminal block. (Inspection by Consignee)" 47

800

18

14800

... More
"Supply of Marker Card as per customer spec. (10x10) (Inspection by Consignee)"

800

92

73776

... More
"Fuse terminal block with LED indication upto 2.5 sq.mm screw type one in one out (suitable for (400 mA, 630mA, 1A. 1.6A, 2A, 4A, 6.3A & 10A) as per RDSO/SPN/189/2004.(without fuse) (Inspection by Consignee)" 49

800

200

160080

... More
"End plate for through terminal block with LED indication. (Inspection by Consignee)"

800

14

11992

... More
"Fuse links of (400 mA, 630mA, 1A. 1.6A, 2A, 4A, 6.3A & 10A) (Inspection by Consignee)" 51

800

47

37976

... More
"Shorting link insulated Grey in colour. (Inspection by Consignee)"

800

16

12984

... More
"Operating tool (operating tool, screw driver & stripper) as per Annexure-VII. (Inspection by Consignee)"

4

9529

38117

... More
"Tool bag complete with Megger as per Annexure-VIII. ADD AC/DC clamp meter, with Hand Held Tool Bag. (Inspection by Consignee)"

4

57453

229812.36

... More
"Supply of Trans-receiver hand held 5 Watt Analog VHF Set along with two sets of OEM 54 approved rechargeable battery including one as spare, quick Battery Charger, Helical Antenna and Belt Clip conforming to RDSO specification no. RDSO/SPN/TC/107/2018 Rev 0.0 with amendment no.1 or later. (Inspection by Consignee)"

30

15100

453001.8

... More
"Supply of VHF 25W transreceiver (synthesised) set complete consisting of Analog Set as per CR specification. (Inspection by Consignee)"

7

26656

186596.62

... More
"Supply of 4.5 Kg CO2 type fire extinguisher alog with all accessaries, extinguisher testig certificate has to be supplied along with - Supply of ISI marked Carbon di Oxide type (BC) fire 56 extinguisher of 4.5 Kg capacity confirming to IS 2878:2004 from seamless cylinder, with IS marked control value, high pressure mtr., Long discharge hose and horn complete with initial gas charged with carrying handle and wall mounting braket etc., as required by Site Engineer. (Inspection by Consignee)"

30

5621

168642.9

... More
"Supply, Installation, Testing & Commissioning of Microprocessor based intelligent, addressable, Fire Alarm Control Panel with LCD display complying to RDSO/SPN/217/2019 Ver 3 or latest modular, 1 loop (minimum 125 detector/devices per loop-expadable to 2 loops) with 320 Character with soft keys for displaying alarm, events and operating functions, Day/Night operation function, Remote maintenance service featgure etc. The panel should be multi-protocol i.e. able to support at least 2 different makes of addressable detectors. The pael should have minimum two relay outputs & 1 Monitored Sounder Output. It should have provision to be connected to repeater panels in future. The pael shall capable to operate on 230 volts AC power supply, automatic battery charger, 24 volts, sealed lead acid maintenance free batteries sufficient for 24 hours normal working and then be capable of operating the system for 30 minutes during emergecy condition. Panel should be VdS Certified. (Inspection by RDSO)"

5

81927

409635.8

... More
"Supply, Installation, Testing & Commissioning of Analogue Addressable Multisensor Detector complying to RDSO/SPN/217/2019 Ver 3 or latest. As per latest VDS approved/Listed. (Inspection by RDSO)"

270

4140

1117889.1

... More
"Supply, Installation, Testing & Commissioning of Manual call points, complying to RDSO/SPN/217/2019 Ver 3 or latest. As per latest VDS approved/Listed. (Inspection by RDSO)"

15

6370

95554.35

... More
"Supply, Installation, Testing & Commissioning of Resettable, Analogue Type Linear Heat Sensing (LHS) Cable complying to RDSO/SPN/217/2019 Ver 3 or latest. As per latest UL or FM or VDS or LPCB approved/Listed. (Inspection by RDSO)"

2000

1723

3447140

... More
"Supply, Installation, Testing & Commissioning of LHS Interface Module with all accessories for single stretch, complying to RDSO/SPN/217/2019 Ver 3 or latest. As per latest UL or FM or VDS or LPCB approved/Listed. (Inspection by RDSO)"

15

163546

2453198.85

... More
"Supply, Installation, Testing & Commissioning of Aspiration (Air Sampling Type) Detection Unit complying to RDSO/SPN/217/2019 Ver 3 or latest. As per latest UL or FM or VDS or LPCB approved/Listed. (Inspection by RDSO)"

15

339271

5089076.1

... More
"Supply, Installation, Testing & Commissioning of CPVC Pipe for Aspiration Detection System complying to RDSO/SPN/217/2019 Ver 3 or latest and shall be listed/approved by UL or FM or VDS or LPCB or tested with appropriate equivalent standard. (Inspection by RDSO)"

2000

1968

3936100

... More
"Supply, Installation, Testing & Commissioning of Analogue Addressable loop powered Monitor Module with inbuilt isolator complying to RDSO/SPN/217/2019 Ver 3 or latest. (Inspection by RDSO)"

15

10659

159895.65

... More
"Supply, Installation, Testing & Commissioning of Analogue Addressable loop powered Control Module complying to RDSO/SPN/217/2019 Ver 3 or latest. (Inspection by RDSO)"

10

10659

106597.1

... More
"Supply,Testing & Commissioning of Hooter cum Strobe complying to the RDSO/SPN/217/2019 Ver 3 or latest. (Inspection by RDSO)"

7

9443

66106.88

... More
"Supply,Testing & Commissioning of 2C 1.5 sq mm twisted shielded armoured copper cable (Per Meter) with accessories complying to the RDSO/SPN/217/ 2019 Ver 3 or latest. (Inspection by RDSO)"

4000

138

552800

... More
"Supply,Testing & Commissioning of Isolator Device to isolate the circuit in case of short circuit, complying to the RDSO/SPN/217/ 2019 Ver 3 or latest. (Inspection by RDSO)"

6

4535

27214.26

... More
"Supply,Testing & Commissioning of Auto Telephone Dialler (GSM) to send the pre- recorded message to multiple mobile numbers, prorammed earlier, complying to the RDSO/SPN/217/ 2019 Ver 3 or latest. (Inspection by RDSO)"

6

11339

68035.8

... More
"CENTRALISED EI Installation, testing & commissioning of EI system complying to RDSO 1 Technical Advisory Note No.STS/E/TAN/3012 Ver.2.0 dated 10.08.2016 and Supply, Installation, testing & commissioning of earthing arrangement for EI as per RDSO specification No. RDSO/SPN/197/2008 at locations/Gumtis/Cabins/EI Huts/Auto Hut of the yard, Earthing of EI equipment, relay racks and Power equipments etc. to be done with Class A Protection, earthing shall be in the form of Perimetric/Ring Earth conforming to RDSO specification and RDSO technical advisory Note for earthing and bonding scheme of EI No. STS/E/TAN/3006 Ver. 1 dt. 02.11.2012 or latest, with earth resistance less than 1 ohm."

2

349496

698992.36

... More
Training of Technician/Engineers/Senior Engineers in installation, for trouble shooting & repairing, commissioning, Testing, Trouble shooting. (Hard copies of training material/course modules to be given to each participant.).

8

55392

443137.84

... More
Installation of Relay Rack Assembly including IDF pillars if any complete with wall 3 supports, scaffolding, ladders, runway for cables, Relay/Relay group base plates, fixing of Tag blocks etc. The work shall be done as per approved plan, extant practice on C. Railways & the instructions of Rly engineer at site.

30

1647

49421.4

... More
Installation, wiring, testing and commissioning of Data logger complete along with 4 accessories with Contractors own wiring & fixing material as per following configuration. (It includes loading of NETWORKING software and networking of data logger. The requisite communication cable/channel for networking will be arranged by Railway. 2560 digital & 32 analog inputs

5

45852

229261.75

... More
Installation of LT Power Panel/Power distribution panel/Auto Changeover Panel, power 5 supply equipments such as Rectifiers Transformers, Battery chargers etc., mounting of Program switches on bakelite sheet of size 300 mm x 300 mm x 8 mm fitted to MS angle (size 25mm x 25mm x 5mm) brackets, wiring as per requirements.Necessary wires to be supplied by Rlys, lugs & glands to be supplied by Contractor.

5

30556

152782.65

... More
Installation and wiring of block instrument. The work of wiring from Telecom DP to 6 block Instrument and block instrument to Relay Room and connection with power supply will be done by the Contractor with Contractor's own wiring & protection material as per instructions of Engineer-in- charge .

4

5878

23513.08

... More
Wiring and charging of Integrated Power Supply to signaling installation. This includes connection of MF Earth of 1 ohm earth resistance for IPS and power distribution connection to bus bars and relay racks in the room with contractor's own wiring materials and fabrication and fixing of AC/DC 7 power distribution board made on 10mm thick Phenolic hylam sheets or any standard make with connections suitable for 63 A.Wiring to be done considering site requirement , depending upon the load with suitable wires,lugs & glands as per instructions of Engineer-in-charge. This item also includes supply & fixing of ladder along the wall for carrying power supply wires/cables from IPS room to Relay room/power room and potential free contact wiring at Datalogger IDF, etc.

5

19314

96570.1

... More
Wiring, fixing & commissioning of modules of fuse 0.6 to 4 Amp. rating alarm system having change over arrangement and potential free contact wiring at Datalogger IDF. etc. as per instructions of Railway Engineer (Module fo 32 nos. fuses) (number=No. of modules)

80

694

55548

... More
Wiring, fixing & commissioning of modules of fuse to 4 to 10 Amp. rating alarm system having change over arrangement and potential free contact wiring at Datalogger IDF. etc. as per instructions of Railway Engineer (Module fo 24nos. fuses) (Number = No. of modules )

50

693

34661.5

... More
Lettering & Numbering of detail and description writing of particulars of terminations & 10 equipments on relay rack, relays, cable termination rack, battery & power equipments, IPS, operating panel, axle counter etc constituting entire system with contractor's own paint and writing material ("Asian/Dulux" make enamel paints to be used). The work shall be done as per extant practice on C.Rly & instruction of Rly engineer at site.(Number = Per RACK )

50

395

19775.5

... More
Fixing of modular terminal/fuse blocks alongwith all accessories with provision of fixing 11 holes on hylam sheets/side angles of Loc Box and fixing by galvanised nuts & bolts. This includes fixing of DIN channel alongwith PVC Comb type 'C' channel (size 2 inch x 2 inch) for cable termination on modular terminal. The PVC channel with cover to be supplied by firm as required. The work shall be done as per the instruction of Rly engineer at site.

8000

20

163600

... More
Installation, testing & commissioning of the 25 W VHF system including the erection of Mast, Antenna, charging of the battery with all Contractor's materials.

7

7642

53496.8

... More
Installation testing and commissioning of Fire Detection, aspiration including flame sensor, LHS cable flame sensor aspiration type smoke sensor as per RDSO SPN No. RDSO/SPN/217/2018 Version 2.0. This includes Control module for the control unit. Monitor module for 13 control unit.LHS Interface should be a microprocessor based start point device that communicates betwwen LHS cable and control unit should be an intelligent device that will monitor LHS cable for continuity and over temperature fire signatures. This also includes Supply, Installation, Testing and commissioning of Integrated Remote Monitoring system Software for complete as per specifications, for integrating, Fire alarm system, VESDA system for monitoring at Division Head Quarter.

6

37253

223518.54

... More
Releasing of Existing Panel, Power Equipments,relays and relay racks, CT racks, 14 Batteries, Block Instts., Ground frame/s, Location Boxes, TLJBs, Signal Posts, Signal Units, Equipment inside the location boxes, Lifting Barrier , rodding runs,etc as applicable including the breaking of foundation etc. as per the instructions of Rly Engineer at site & their transportation to nominated depot.

6

37787

226725.96

... More
"Design, maufacture and supply of Electronic Interlocking (EI) system (Hot Standby) complete {as shown in plan} as per RDSO specification No. RDSO/SPN/192/2005 with latest amendment and RDSO Technical Advisory Note No. STS/E/TAN/3012 dated 28.08.2014 with latest amendments regarding Technical System Application Approval for Electronic Interlocking (EI) installations as per the technical requirements and tentative approved Signalling Plans & Diagrams with OEMs specification. (Inspection by RDSO) Electronic Interlocking (EI) system mainly consisting of Central Processsing Equipment, Interface Equipments, cards and all types of required Interface Relays, EI racks etc. as per requirements, dual operator Industrial Grade PC with VDU panel (55"" LED 2 nos. or bigger) with Redundancy as per the RDSO technical advisory Note No. STS/E/TAN/3007 Version 1 1 dt. 02.112.12 or latest (Hot standby dual VDU Normally one system will be online and other system will be in standby mode), All types required Interface Relays suitable for EI, interconnecting cables and Jumper wires, fuses etc to be supplied by tenderer. It also includes provision of Industrial grade maintenance Terminals (42"" LED or Bigger with UPS minimum 2 hr back up), required power supply DC-DC converters for EI equipments, Housing for EI equipments and enclosures, fuses, screw less disconnecting type terminals, fixture mounting arrangements and accessories necessary to make the EI system functional as per approved signalling plan. And supply of Protocol Convertor for Data logger as per instructiion of engineer-in-charge. The tenderer should furnish complete details of cards/modules/sub-modules connectors, relays etc, for each station. System has 25 % spare ports to accomodate additional input/output and I/O cards for minour alteration in future with provision for accomodating additional 25% of Logical Bit spares/Timer spares in each CIU/Card File Level for facilitating minor alterations."

-

-

150196382.08

... More
"Supply of Essential spares (10% of main equipment / module for EI system) of the input cards/modules as specified by OEM. (Inspection by RDSO)"

-

-

10778647

... More
"Provision of Ring Earth (Maintenance Free Earth) arrangement as per RDSO specification No. RDSO/SPN/197/2008 with latest amendments. This includes supply of all required material as per latest RDSO's guidelines. (Inspection by RDSO)"

5

965250

4826250

... More
Installation, testing and commissioning of Solid State Block proving by Axle Counter for Single line.

2

18136

36272.26

... More
"Supply, Installation, Testing and Commissioning of SMPS based Integrated Power 1 Supply confirming to RDSO specification RDSO/SPN/165/2012 version 3.0 for PI station up to 6 lines as per Central Railway drawing No. R-ST/C/DR/2019 with latest correction if any as per Annexure-I. Scope of supply, checking of installation & commissioning of IPS shall be as per RDSO letter No. STS/E/IPS/Genl dated 03.04.2008 or latest if any. (Inspection by RDSO)"

5

1734394

8671970.6



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.