Central Railway Tender

... More
Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.

Central Railway - CR Tender

Works
Electrical Goods and Equipments
Electrical and Electronics
Ireps
Opening Date27 May 2024
Closing Date28 Jun 2024
Tender Amount₹ 14,72,05,130.77 
Notes
Download

Costs

Summary

Provision Of Axle Counter In Water Logged Track Section Of Various Stations Of Bsl Division

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply of PVC Indoor Cable 1x60x0.6mm dia colour coding of insulation of inner core shall be in six colour Viz Blue , Red , Grey ,Green, Brown and Black conforming to IRS 76/89(Amdt 3) or latest. (Inspection by Consignee)

3.5

300675

965545.19

... More
Supply of PVC Indoor Cable 1x 40x0.6mm dia. Colour coding of insulation of inner core shall be in eight colour viz Blue,Red,Grey,Green,Brown,Black, Yellow & white.conforming to IRS 76/89 (Amdt 3) or latest. (Inspection by Consignee)

3.5

197250

633420.35

... More
Supply of PVC indoor cable 1 x 24 x 1 mm dia. Colour coding of insulation of inner Conductor shall 6 be in eight colour viz Blue,Red,Grey,Green,Brown,Black, Yellow & white.conforming to IRS 76/89 (Amdt 3) or latest. (Inspection by Consignee)

8

292637

2147961.31

... More
Supply of Indoor Jumper Wire of various colour as per Railways standard practice of type ATC 1 x 0.6 mm dia.conforming to IRS 76/89 (Amdt 3) or latest. (Inspection by Consignee)

50

8647

396713.7

... More
Supply of Indoor Jumper Wire ATC 1 x 1 mm dia. conforming to IRS 76/89 (Amdt 3) or latest. (Inspection by Consignee)

4

13093

48053.29

... More
Supply of PVC Flexible Copper Cable, Single core, multi strand 1x2.5 sq mm(50 conductor each dia 9 0.25 + /- 0.01) as per specn IRS 694/2010 with latest amendment. If any with insulation thickness of 0.70 mm nominal conductor resistance 7.98 ohms /km and test parameters are as per (S)76/89 (Amdt .3). (Inspection by Consignee)

7

44575

286287.11

... More
Supply of PVC Flexible Copper Cable, Single core, multi strand 1x10 sq mm(80 conductor each dia 10 0.40 + /- 0.01) as per specn IS 694/2010 with latest amendment. If any with insulation thickness of 1.00 mm nominal conductor resistance 1.91 ohms /km and test parameters are as per IRS (S)76/89 (Amdt .3). (Inspection by Consignee)

8

141059

1035375.26

... More
Supply of wire 16/0.2 (blue,red,gray,yellow, brown,black, white as per site engineer instruction) finolex/polycab/ delton make.IRS:S-76/89(Amd.3),BS:4808 Part-2.Wire to be procured from RDSO approved vendor (Inspection by Consignee)

4

6445

23653.77

... More
Sealed maintenance free VRLA Battery/Cell 2 volt,300AH IRS:S-93/96(A)(Amd.1) or latest in set of (55+5) with fittings and accessories. (Inspection by RDSO)

240

5040

1109808

... More
Supply of Transformers 230V/110V-130V Single Phase 2 KVA as per spec IRS S-72/88 (Amd.2)with latest amendments.(Inspection by Consignee)

16

10876

159670.54

... More
Supply of Battery Charger self regulating floor mounting type with 230 V AC Single phase input and output 60V DC,40A as per spec.IRS.S.86/2000(Amd.4)with latest amendment.(Inspection by RITES)

7

130799

840060.88

... More
Supply of Battery Charger self regulating floor mounting type with 230 V AC single phase input and output 110V DC,40A to spec.IRS.S.86/2000(Amd.4)with latest amendments.(Inspection by RITES)

7

93822

602573.02

... More
Supply of Battery Charger self regulating floor mounting type with 230 V AC single phase input and output 24V DC,30A as per spec.IRS.S.86/2000(Amd.4)with latest amendments.(Inspection by Consignee)

7

32092

206115.24

... More
Supply of Automatic Changeover for individual supply Automatic changeover unit of 17 signal/Track/DC circuit supply of 32A, AC/DC consisting of 3TC 44 contactors, LED Lamp,Push button, terminals,VSR,polarity switches. As per Rly.drg-SK-841/1-5 for IPS supply to mannual discrete equipments with P/switch. (Inspection by RITES)

21

29381

566109.59

... More
Relay base plate complete with amophanols,code pins fixing screw etc.suitable for Metal to Metal 18 K-50 mini groups/ECRs of Siemens Make of functional equivalent of other makes. Note: Relay Base plates,are to be procured fom Relay manufacturer (OEM) Manufactures Certificate for procurement and guarantee in this regard should be furnished.The payment to be released only after Manufacturers Certificate is submitted. (Inspection by Consignee)

100

729

66963.74

... More
Supply of Plug In type Relay Metal to Metal type neutral relay mini groups (Non AC Immunised) 19 Siemens make (No. RSSK 30/0011) (Ref. IRS:S46/74 with Amd. 1 & firms specification.).or functional equivalent without base plates.Contact configuration 5F/3B or 6F/2B or 4F/4B to be specified by Engineer incharge. (Inspection by RDSO)

120

7143

786446.5

... More
Supply of INDICATIVE TYPE OF FUSE INSERTS. IRS S:-78-92 A) With holder 1.6 A (System, Rapid or Mainad Make). (Inspection by Consignee)

400

79

29330.64

... More
Supply of INDICATIVE TYPE OF FUSE INSERTS. IRS S:-78-92 B) With holder 0.6 A (System, Rapid or Malnad Make) (Inspection by Consignee) 121Ad 1000.00 Numbers 23.02 23020.00 (-) 8.25 21120.85 22

50

77

3541.09

... More
Supply of INDICATIVE TYPE OF FUSE INSERTS. IRS S:-78-92 E) Without holder 0.6 A (System, Rapid or Malnad Make (Inspection by Consignee)

100

23

2112.09

... More
Resin cored wire as per specification No. IS:1921-1975 with Alloying element percentage as 63% 24 SN (Tin) and / 37% Pb (Lead) with percentage of various impurities not exceeding the values Sb (Antimony) 0.2% maximum , Cu (Copper) 0.1% maximum, As (Arsenic) 0.05% maximum, Fe (Iron) 0.02% maximum & other impurities mainly Al, Zn & Cd shall be limited. The flux shall be free from corrosive action as per clause 5.2 & flux percentage may be used as per requirement. (Inspection by Consignee) 128A 50.00 Numbers 66.15 3307.50 (-) 8.25 3034.63

4

1252

4596.97

... More
Lacing thread rolls, black, wax coated (100 mtrs) (Inspection by Consignee)

50

66

3034.63

... More
Design,fabrication and supply of fuse Auto changeover system for 32 Nos of external non 26 detorating Type fuses of G type fuses from 0.6 A Amp to 4A Amp capacities used in signalling circuits.System shall have 8 cards with monitoring arrangement of 4 fuses in onee card.As per RDSO spec.RDSO/SPN/209/2012 Ver.2.0 or latest amendment if any. (NO. OF MODULES=NUMBER) (Inspection by RDSO)

16

26760

392840.18

... More
Supply of Phenolic 10mm thick sheet, grade P3 in standard size of 1.22X1.22 Mtr as per spec. No IS 2036 of 1995. (Inspection by Consignee)

85

5250

409471.81

... More
Supply of ARA Terminal blocks with links made of PBT Specn No.IRS/75/2006(Rev - 2) with latest amendments and RDSO Drg.No.SA-23741 Alt.4., SA-23745 Alt 5, SA-23746, SA-23748 Alt -4 & SA-23756 Alt-3. (Inspection by RDSO)

24500

72

1632182.04

... More
Supply of cartridge fuse block made of PBT as per RDSO Drg No SA-23748 Alt 4,SA-23749 & Spec No IRS S 75/2006 with latest amendment. Fuse block shall be suitable for round head type voltage fuses. (Inspection by RDSO)

800

162

119597.96

... More
Supply of round head type non detoriating type low voltage cartridge fuse as per Specn No IRS/S/78/92 with latest amendments2A/4A/6A capacity (Inspection by Consignee) 161A 76.00 Numbers 33.41 2539.16 (-) 8.25 2329.68

800

70

51475.42

... More
Supply of Lamp 110V/24W,2 Pin for Loc. (Inspection by Consignee)

207

22

4316.94

... More
Supply of Apparatus Case with godown locks with deatachable handle on both the doors. A) Single Case as per Drg No SK 783-1/2. with latest alteration.(Inspection by RITES) 165A 76.00 Numbers 1078.08 81934.08 (-) 8.25 75174.52

76

16020

1117078.09

... More
Supply of earth electrode assembly as per Drg.No.CR/S&T/SK/815 (Inspection by Consignee)

76

1078

75174.52

... More
Maintenance Free Earth As per RDSO/SPN/197/2008 or latest consisting of :1) Copper bond steel electrod 3 Mtr long 17 mm dia with copper bonding thickness of min.250 micron & UL listed & marked -01 No 2) 36 Earth enhancement compound RDSO Approved in sealed bag of 10Kgs-03 No 3) Copper strip 150x25x6 mm -02 No 4) Copper strip 300x25x6 mm -01 mm 5)35 Sqmm Copper Cable to connect earth electrod to MEEB-15 Mtr Approx. If required , additional earth enhancement compound shall be provided free of cost to ensure earth value below 01 ohm. (Inspection by RDSO)

168

17786

2741584.91

... More
Supply of Electronic timers for DAC reset arrangement 3 sec to 30 sec with 2 NO/2NC contact working voltage 24V/60V DC siemens/ABB/L&T or SELEC(642xA programmable electronic timer switch)make (Inspection by Consignee)

84

2819

217281.91

... More
Supply of Multi strand twin twisted core shielded cable of 28-30/0.2 mm for Axle counter as per IRS 38 spec. 76/89 with latest amendments, if any (PER 100 METERS= METERS(Inspection by Consignee).

30

14963

411864.28

... More
Supply of GI pipe, inner dia. 100mm dia. B-class as per spec. No.IS 1239 PT.1/2004 or latest with sockets and fittings. TATA/JINDAL/ZENITH BIRLA Make. (Inspection by RITES)

2000

1029

1888802.2

... More
Supply of DWC HDPE Pipe with one snap fit coupler and 'O' ring fire resistant, anti rodent,in 6mtr length of size 120 mm outer dia as per RDSO /SPN /204/2011/Ver 1.1 with Amdt 1 or latest. (Inspection by RITES)

3000

321

884736.07

... More
"Supply of RCC pipe half round of size 150mm dia outer and 100 mm dia internal 1 mtr long matching to IS No.458/2003 amendment-1 with Rev.4. (Inspection by Consignee)"

5000

206

945667.25

... More
Supply of Modular Terminal block of 2.5 sqmm 2 IN 2 out type disconnect type terminal along with 42 a s per RDSO Specn.No.RDSO/SPN/189/2004 Rev 3.0. The current capacity of 16 Amps & more,The terminal should have marking at centre to view description from front. The terminals should have latest push -X technology for easy wiring. Material to be procured from RDSO approved firm only preferably of phoenix make. (Inspection by Consignee) 220A 60.00 Numbers 216.73 13003.80 (-) 8.25 11930.99

4000

117

429830.4

... More
Supply of marker card as per customer spec(10x10) (Inspection by Consignee)

20

83

1537.91

... More
Installation of relay rack assembly including IDF pillars if any complete with wall support, scaffolding, ladders, runway for cables,Relay/Relay group base plates, fixing of Tag block etc.The work shall be done as per approved plan, extant practice on C. Railway & instruction of Rly. Engineer at site.

22

1534

30978.53

... More
Installation of Cable Termination Racks Assembly complete including wall supports, scaffolding, Disconnecting links/ARA terminal, 96 way tag block cover & other necessary accessories etc. The work shall be done as per approved plan, extant practice on C. Railways & the instruction of Rly engineer at site.

8

1306

9590.66

... More
"Fixing of Q series relay base plate/metal to metal relay mini group and major group base plate, laying, bunching, lacing, dressing & packeting of 60/40 core PVC indoor cable/flexible wire and termination of 3 60/40 core cable/flexible wire on tagblock/base plate & base plates & soldering. This includes fuse wiring, bus bar looping etc. required for keeping installation ready for circuit wiring work & panel throughing work. The work shall be done as per approved plan, extant practice on C.Rly. & the instruction of Rly. Engineer at site." (Tag Block=NUMBER)

80

626

45955.01

... More
Circuit wiring/jumpering as per circuit diagrams in the relay racks/IDF rack tagblocks. This 4 includespreparation of Jumper sheets by wire man duly checked by firm's site supervisor & wire to wire testing as per circuit diagram. Any wrong jumper done by wireman will not be paid & correction shall be done free of cost.Jumper wires will be issued by Railways. Good quality solder rosin core to be supplied by contractor for soldering of Jumper wires. Soldering of jumper wires (JUMPER=NUMBERS)

24000

12

267983.4

... More
Wiring,Fixing & commissionig of modular of fuse 0.6 to 4 Amp rating alarm system having change over arrangement and potential free contact witing at Datalogger IDF Etc as per instruction of Railway Engineer (Module of 32 nos fuses) (NO OF MODULES=NUMBERS)

16

646

9496.05

... More
Lettering & Numbering of detail and description writing of particulars of terminations & equipments 6 on relay rack, relays, cable termination rack, battery & power equipments, IPS, operating panel, axle counter etc constituting entire system with contractor's own paint and writing material ("Asian/Dulux" make enamel paints to be used). The work shall be done as per extant practice on C.Rly & instruction of Rly engineer at site.

32

368

10818.28

... More
Fabrication and fixing of phenolic laminated/Fibre glass sheet in location box by providing all 7 fixtures as per Railway Drawing including fixing of PVC coated/with PVC pipe covered string rods at the back side for cable support with contractor's own materials. The work shall be done as per drg and arrangement similar to SK 783-1/2. with latest alterations & as per instructions of Rly engineer at site. A) SINGLE CASE Per 44B 24558.00 14.05 345039.90 (-) 8.25 316574.11

76

2251

157013.13

... More
Excavation and Casting of Apparatus Case foundation with contractors Anchor bolts, cement, ballast and other materials.The required Scaffolding Ferma etc for Casting of foundation will have to be brought by the contractor ar his own cost A) Single Case as per Drg No SK 803

76

9887

689421.9

... More
Erection of Apparatus Cases. This includes filling of location foundations and plastering A) Single Case

76

1098

76566.33

... More
Installation of Eqpt. (Relays, resistance, chargers batteries etc.as applicable) & wiring of the same in apparatus Cases as per location diagrams & circuit diagrams, as per Instruction of site incharge and practice. A) Single Case(Inspection by Consignee)

76

1497

104436.02

... More
Installation of earth electrode assenbly as per Drg.No.RE/S&T/SIG/Tender/SK726/85 including earth wire connected through GI wire 8 SWG supported on M.S. flat of size 6mm x 40 mm to earth electrode as 13 per drg. No.CR/S&T/SK-815 for sigg. Equipment such as lever frames, apparatus case, signals, relay racks,block insruments, and etc. as per RE manual. The earth value should be less than 10 Ohms including the lead wire. The value should be measured in presence of Rly. supervisor. It should be documented and painted on earth enclosure made of concrete.( only earth electrode will be supplied by Railway). All other material required for provision of earthing will be brought by the contractor.

76

2528

176287.2

... More
Installation of unit earth as per RDSO/SPN/197/ver I or latest, to construct earthing of

168

5290

815453.01

... More
Supply, fixing & Wiring of mismatch panel dipcting Indication Panel/VDU layout with contractors own material like LEDs for each track section, flexible wire, connecting terminals, buzzer etc. The work shall be done as per extant practice on C. Rly & the instruction of Rly engineer at site.(Inspection by Consignee)

8

50121

367890.42

... More
Excavation of cable trench as per cable route plan,1.0 mt. deep and 300mm wide along side the track in normal soil/strata, conforming to distances as per cable route plan and refilling after cable laying. This work includes covering of cable laid in trench by loose soil for a layer of 50mm thickness after clearing of 16 route,bushes etc.It shall be ensured that top of the cables laid is at a depth of 0.8 m or more If it is less,then the width and depth shall be suitably increased and accordingly proportuonate payment shall be made .In case depth of trench is not achievable due to site conditions,Proportionate payment will be made as per procedure.The work shall be done as per the extant practice on Central Railway and instructions of Railway Engineer at site.Drg No.SK 805

4500

350

1445062.5

... More
Excavation of cable trench as per cable route plan,1.0 mt. deep and 300mm wide along side the track in hard soil, conforming to distances as per cable route plan and refilling after cable laying. This work includes covering of cable laid in trench by loose soil for a layer of 50mm thickness after clearing of route,bushes 17 etc.It shall be ensured that top of the cables laid is at a depth of 0.8 m or more If it is less,then the width and depth shall be suitably increased and accordingly proportuonate payment shall be made .In case depth of trench is not achievable due to site conditions,Proportionate payment will be made as per procedure.The work shall be done as per the extant practice on Central Railway and instructions of Railway Engineer at site.Drg No.SK 805

1600

583

856328.44

... More
Cutting of all types of Roads/ platforms (except concrete type ) for trenching and excavation to depth of 300mmx300mm wide approx. and refilling after laying of RCC/GI/DWC pipe & to restore them to original condition. The work shall be done as per extant practice on C.Rly & instructions of Rly engineer at site.SK-807

250

2916

669011.18

... More
Fixing of GI pipes for crossing the culverts, bridges etc. and concreting of ends with brick masonry at both ends as per the instruction of Rly engineer at site.

2000

69

128394.95

... More
Digging of trench 1.0M deep from rail flange/road level (for LC) and 0.3 mtrs to 0.6 Mtrs wide and 20 back filling after placing of DWC/RCC/GI pipe (Placing of DWC/RCC/GI pipe coverd separately) The ballast disturted be screened and dressed as required by Engineerin-charge or his representatives and road tarred immediately.Drg No.SK 806

800

583

428164.22

... More
Laying of DWC/RCC pipes alongwith collars/RCCHalf round pipe in trenches at places of track and road crossings, platform cuttings etc. 87B 326.00 Kilometre 5197.42 1694358.92 (-) 8.25 1554574.31

3000

56

156479.63

... More
Laying of signalling/Power/Telecom cable of various cores/sizes in trenches.

326

5197

1554574.31

... More
Placing and securing of cable route markers in trenches at the specified interval and at diversions, joints etc along the cable route. The work shall be done as per extant practice on C Railways & the instruction of Rly engineer at site.

450

12

5173.32

... More
Whereever depth of 0.5 m cable trench is not feasible cable shall be protected as under :- Preparation of cement mixture 1:3:6 with contractor's own materials and spreading cement concrete mixture layer of 100 mm thick over the already laid cables in the excavated trench.

160

5329

782377.94

... More
"Fixing of modular terminal/fuse blocks alongwith all accessories with provision of fixing holes on 25 hylam sheets/side angles of Loc Box and fixing by galvanised nuts & bolts. This includes fixing of DIN channel alongwith PVC Comb type 'C' channel (size 2 inch x 2 inch) for cable termination on modular terminal. The PVC channel with cover to be supplied by firm as required. The work shall be done as per the instruction"

4000

19

69913.5

... More
Horizontal boring of cable duct of minimum 2.0 mtr depth along with laying of 120 mm HDPE pipe for track crossing wirh minimum depth reckoned from bottom of the rail/Road crossing with minimum depth 26 reckoned from ground level. The work shall be done as per extent practice & instruction of site engineer.Preparation of site for Horizontal boring shall be carried out in presence of Railway Representative.HDPE will be supplied by Railway. Note:- Contractor shall provide all material required for boring and adequate nos.of labours for proper laying of cable into the bore.Cable shall be laid cautiously so that it should not get damage due to rough handling & pressure on cable.

2400

2610

5748232.92

... More
Laying of RCC half round cement pipe of approximate size (150/300 mm dia X 2 Meter length) inside the trench after laying of cable. Pipes shall be placed as per directives of engineer

5000

36

167214.38

... More
Painting of two coats of synthetic enamel paint over one coat of primer on the following after scraping & cleaning surface wherever necessary with contractor' own supply of paints.Wherever required 28 contractor shall apply coating of epoxy paint also as per instructions of site-in-charge.Epoxy paint will be supplied by Railways. NOTE:- The paint and primer should be from M/s Asian paints Co. Ltd.,. The paints will be primer (IS 5660 of 1970) the Aluminium synthetic black enamel (IS 2932 of 1974) brilliant white and yellow Painting two coats of enamel paint over one coat of primer.A) Apparatus Case Full Size.

76

435

30363.23

... More
Lettering / Numbering of Signals, Point Machine, Track Lead Junction Boxes, Block Joints, Apparatus Cases etc. (each item to be taken as One Unit) This work will be carried out as per the standard practice being followed in Central Railway.

76

56

3949.51

... More
Lettering / Numbering Termination particulars, equipments names etc., legibly and neatly inside location boxes. A) Full Case.

76

263

18375.95

... More
Supply of cable route marker as per RST/C/203 of FRP. (Inspection by Consignee)

450

360

162396

... More
Design of alteration in existing Signalling Circuits & supply of modified signalling circuits including Panel diagram , Route section Plan , Selection Table , Fuse & Negative Tag. Analysis , Contact analysis , Relay Rack Arrangement and wire count sheets etc. in A3 size.Completion circuit shall be plotted in AutoCAD. The 2 contractor shall initially supply 2 sets of circuits duly signed by the circuit designer having substantial experience on design side for making such circuits, complete for approval of Railways. Railways will return one set of circuit to the contractor duly approved with alterations /corrections, if any. The contractor/Railway will commission the station with the based on these approved circuit diagram. The contractor will submit final tracing & CD ( soft copy of Drg.) based on panel testing,break test,square sheet test etc. to Railway for their final approval.complete in all respects along with 4 sets of final .

8

95000

760000

... More
TRMS Datalogging DMM Fine Tipmultimeter make-Rishabh 6016 or similar (Inspection by Consignee)

8

21956

175649.12

... More
Supply of True RMS Multimeter Fluke Make model 289 or similar (Inspection by Consignee)

8

60425

483407.28

... More
Supply of Polyolefin Cable channel with following dimensions, height (internal/external) 155mm/230mm x width 240mm/340mm x length 1000mm with suitable detachable cover having fire protection (Inspection by RITES)

15000

2431

36470550

... More
Laying of RCC Trunking / Ployfin cable channel and capping and sealing after cable laying as per std practice on C.Rly & the instruction of site engineer. (Inspection by Consignee)

15000

70

1059300

... More
Supply of DC-DC converter modules of IPS of various supplies/make.(As per site requirement.) (Inspection by RDSO)

32

13782

441024

... More
Supply of Cabinet with wiring arrangement for DC-DC converter 08 Nos. suitable for Station (Inspection by Consignee)

4

59722

238888

... More
"Supply & testing of precision Cable locator / Route tracer with MXT4 Transmitter & Signal Clamp of 9 make CSCOPE U.K or its equivalent as per enclosed specification. ACCEPTED FIRM'S OFFER MAKE - CSCOPE, U K : MODEL -MXL4 . PURCHASE PROOF FROM OEM/ AUTHORISED DEALER AND OEM'S WARRANTY CERTIFICATE ARE TO BE SUBMITTED ALONG WITH SUPPLY. MATERIAL IS TO BE SUPPIED AS PER TENDER DESCRIPTION AND SPECIFICATIONS ." (Inspection by Consignee)

2

389400

778800

... More
Supply of TELEMETRICS Rechargeable Handheld Telecom TDR Cable Fault Locator 1 year Brand: TELEMETRICS (Detailed description /Specification as per Product # 1 of GeM Contract No. GEMC511687710737935 dt.17/02/2023)(Inspection by Consignee)

1

201665

201665

... More
Chase cutting 500mm deep in hard rocky area as per DRG Ni- CORE/S&T/ALD/SK/579/04 per meter (Inspection by Consignee)

350

303

106249.5

... More
Supply of Bumpless Automatic power source change over Device DC -20V-120V,min 40 A (2 input sources) Model no. PT-RSA-HL-DC-04 or RE-SDSM-40 or similar.(Inspection by Consignee)

16

54516

872256

... More
"Installation of item Automatic changeover unit of signal/ Track /Point supply of 32A, DC consisting of 3TC44 contactors or similar , LED Lamp, Push button terminals, VSR, polarity switches. " (Inspection by Consignee)

37

5325

197057.19

... More
Supply of Digital Clamp ON EARTH Tester ( make: HTC CE8201 or Fluke make ) LCD display Auto ranging Digital Earth Resistance Meter. The tester shall have 02 years of OEM warranty. (Inspection by Consignee)

2

49367

98735

... More
Supply of Drill bit 7.2mm (Inspection by Consignee)

50

125

6250

... More
"Supply of Cycle drill machine hand operated parallel type. " (Inspection by Consignee)

4

9723

38892

... More
"Supply of Battery operated rail core drill along with additional 18 mm TCT rail core drill. Maximum core cutting capacity 36mm, rated speed 250/450ZRPM, Battery type Lion, Battery voltage 50V,Battery pack 18 capacity 4AH,Number of battery supplied - 2No. Charger-1No. Special design pressurized internal spindle cooling to give maximum life of core cutter by avoiding heating.3 sets of 22,13,16,7.2 gauge drills adapters to be provided along with the machine,weight of machine with battery18.5Kg Make:Eibenstok, Bosch, KPT " (Inspection by Consignee)

2

241088

482177.84

... More
"Supply and installation of SMPS based Battery Charger 230V AC Single phase 50HZ supply, output voltage 160V to 190V DC/40A for Point machine operation and suitable to charge 90 cells of VRLA batteries. Make:Statcon or Amara Raja or HBL. (Inspection by RDSO)"

2

278414

556829.72

... More
"Supply of High speed ratchet type drill bit. Size- 13 mm dia. Full length 145 mm flute Excise Duty - length 90 mm as per IS specn. IS: 503 DIN 345 square shank. Make - IT/MIRANDA/ JK, HSN code - 8207"" (Inspection by Consignee)."

11

1550

17050

... More
"Supply of Electric drill machine 13 mm impact CAT No.KPT563 power input 550- W no load speed 1200 RPM drilling capacity 13/25/210 KPT make. (Inspection by Consignee)."

5

7500

37500

... More
"Supply & installation of Network Activity report generation system suitable for A4 size paper make- HP or EPSON or Canon. (Inspection by Consignee)."

4

16500

66000

... More
"Supply of 128 inputs digital tag block.For Up gradation of existing data logger of stations." (Inspection by RDSO)

4

15000

60000

... More
"Supply of Rare plate and 64 Pin Connectors. For Up gradation of existing data logger of stations." (Inspection by Consignee)

8

25000

200000

... More
"Supply of Yard Simulation and Digital input updation Software. " (Inspection by Consignee)

4

25000

100000

... More
Supply of Euro rack (Inspection by Consignee)

4

25000

100000

... More
Supply of Housing Rack . (Inspection by Consignee)

4

35000

140000

... More
Testing and commissioning of 512 digital inputs (Inspection by Consignee)

4

20000

80000

... More
Installation, wiring & Testing/commissioning of Axle counters Reset Box of all types in Cabin/Panel 1 Room and wiring the same to integrate with the axle counter as per the instruction of Railway engineer at site. This includes laying & termination of cable, if any from Panel Room/Axle couter room/Relay room to Reset Box in DWC pipe/existing ladder. Per 75B 168.00 Detection 956.92 160762.56 (-) 8.25 147499.65

8

7665

56263.82

... More
Fixing of track devices ( Transmitter coil and receiver coil ) to the rails , fixing of EJB in the location 4 ,connection of track device to EJB using DWC pipe of suitable length and wiring of EJB ,testing and adjustment of transmitter and receiver to obtained required channel level as per standard practices on C.rly and instructions of Rly Engineer on site Per

168

10748

1805801.76

... More
Wiring and charging of Integrated Power Supply to signalling installation.. This includes connection of MF earth of 1 ohm earth resistance , for IPS and power distribution connection to bus bars and relay racks in 1 the room with contractor's own wiring materials and fabrication and fixing of AC/DC power distribution board made on 10mm thick Phenolic hylam sheets or any standard make with connections suitable for 63 A.Wiring to be done considering site requirement , depending upon the load with suitable wires,lugs & glands as per instructions of Engineer-in-charge. This item also includes supply & fixing of ladder along the wall for carrying power supply wires/cables from IPS room to Relay room/power room and potential free contact wiring at Datalogger IDFetc.

4

31176

114418.78

... More
Supply, checking of installation, testing and commissioning of SMPS based integrated power supply conforming to RDSO Specifications RDSO/SPN/165/2012 Version 3.0 with latest amendments for Panel Interlocked station as per Central Rly. Drg.No.SK-790/1/A with latest ammendments,if any. (Inspection by RDSO)

4

1521582

6086331.44



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.