Central Railway Tender

Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.

Central Railway - CR Tender

Works
Telecommunication Services
Ireps
Opening Date26 Dec 2024
Closing Date21 Jan 2025
Tender Amount₹ 28,54,41,840.28 
Notes
Download

Costs

Summary

Supply, Installation, Testing & Commissioning Of Indoor & Outdoor Signaling Work Including Provision Of Electronic Interlocking At Jalgaon Station & Jalgaon-bhadli Automatic Block Section With Modification / Alteration In Existing Electronic Interlocking At Bhadli Station And Jalgaon-bhadli Automatic Block Section Including Utility Shifting In Connection With Jalgaon-bhadli 5th Line Work In Bhusawal Division Of Central Railway

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply of Data logger for monitoring status of important relays, complete with Processor Module to monitor following inputs as per spec. RDSO/SPN/99/2006 Spec. No.: IRS-S-99/2006 4 (Amdt-3) with latest amendments including power supply of adequate capacity, battery and faultdiagnostic software for failure analysis. Complete data logger & Processor Module(computer) as per Annexure shall be placed in President rack of suitable size to be supplied. This also includes supply of one no composite computer & printer table (work station table- Gorej/Durian/Transteel) for keeping Processor module and one no Godrej/Durian/Transteel make operator chair. - 1024 digital and 32 analog inputs (Inspection by RDSO)

7

718998

5938929.67

... More
Supply of PVC Indoor Cable 1 x 24 x 1 mm dia Colour coding of insulation of inner conductor shall be in eight colour viz Blue, Red, Grey, Green, Brown, Black, Yellow & White conforming to IRS 76/89 (Amd.3) or latest. (Inspection by RDSO)

7

292637

2417188.06

... More
Supply of Indoor Jumper Wire ATC 1 x 1 mm dia. conforming to IRS 76/89 (Amd.3) or latest. (Inspection by Consignee)

16

13093

247206.04

... More
Supply of PVC flexible copper cable single core multistrand 1 x 2.5 Sq.mm (50 7 conductor each diameter 0.25 +/- 0.01) as per IS 694/2010 with latest amendment if any.with insulation thickness of 0.70mm nominal conductor resistance 7.98 ohms/Km and test parameters are as per IRS (S)76/89 (Amd.3). (Inspection by RITES)

16

44575

841588.27

... More
Supply of PVC flexible copper cable single core multistrand 1 x 6 Sq.mm (84 conductor 8 each diameter 0.30 +/- 0.01) as per IS 694/2010 with latest amendment if any.with insulation thickness of 0.80mm nominal conductor resistance 3.30 ohms/Km and test parameters are as per IRS (S)76/89 (Amd.3). (Inspection by RITES)

14

91617

1513517.96

... More
Supply of PVC flexible copper cable single core multistrand 1 x 10 Sq.mm (80 9 conductor each diameter 0.40 +/- 0.01) as per IS 694/2010 with latest amendment if any.with insulation thickness of 1.0mm nominal conductor resistance 1.91 ohms/Km and test parameters are as per IRS (S)76/89 (Amd.3). (Inspection by RITES)

21

141059

3495449.45

... More
Supply of PVC flexible copper cable single core multistrand 1 x 16 Sq.mm (126 10 conductor each diameter 0.40 +/- 0.01) as per IS 2465/1984 & IS:694/2010 with latest amendment if any with insulation thickness of 1.0mm nominal conductor resistance 1.121 ohms/Km and test parameters are as per IRS (S)76/89 (Amd.3). (Inspection by RITES)

16

209928

3963446.3

... More
Supply of PVC flexible copper cable single core multistrand 1 x 25 Sq.mm (196 11 conductor each diameter 0.40 +/- 0.01) as per IS 2465/1984 & IS:694/2010 with latest amendment if any with insulation thickness of 1.2mm nominal conductor resistance 0.780 ohms/Km and test parameters are as per IRS (S)76/89 (Amd.3). (Inspection by RITES)

10

326216

3849354.35

... More
Supply of wire 16/0.2 (Blue, Red, Grey, yellow, Brown, Black, White as per site engineer instruction) finolex/polycab/delton make. IRS S-76/89 (Amd.3), BS: 4808 Part-2. Wire to be procured from RDSO approved vender. (Inspection by Consignee)

26

6445

197737.82

... More
Supply of low maintenance Lead Acid Secondary Cells 2V 80 AH as per spec. IRS 88/2004 with latest amendments. (Inspection by RDSO)

420

1997

989792.5

... More
Supply of Program switches, snap action, base mounting type along with cover and mounting bracket 63A-7 pole 3 position Siemens type (3 LAO-63/7Y) / L&T/HAVELLS type. Drg. No. RST.C.106 (Inspection by Consignee)

16

9226

174201.8

... More
Supply of Transformer 230V/110V-130V Single Phase 2 KVA as per spec. IRS S-72/88 (Amd.2) with latest amendments. (Inspection by RDSO)

29

10876

372202.04

... More
Supply of Battery Charger self regulating floor mounting type with 230 V AC single phase input and output 60 V DC, 20A as per spec. IRS.S.86/2000 (Amd.4) with latest amendments for Axle counter applications(Inspection by RDSO)

12

52992

750376.21

... More
Supply of Battery Charger self regulating floor mounting type with 230 V AC single phase input and output 24 V DC, 10A as per spec. IRS.S.86/2000 (Amd.4) with latest amendments. (Inspection by RDSO)

20

40356

952413.64

... More
Supply of Battery Charger self regulating floor mounting type with 230 V AC single phase input and output 24V DC, 20A as per spec. IRS.S.86/2000 with latest amendments for Axle counter applications (Amd.4). (Inspection by RDSO)

8

36438

343976.32

... More
Supply of Rubber Mat 10mm thick for use in signalling installation. (Inspection by Consignee)

700

129

106991.78

... More
Supply of Automatic changeover for individual supply. Automatic changeover unit of 20 signal/Track/ DC circuit supply of 32A, AC/DC consisting of 3TC44 contractors, LED Lamp, Push Button, terminals, VSR, polarity switches. As per Rly. Drg.-SK-841/1-5 for IPS supply to mannual discrete equipments with P/switch. (Inspection by RDSO)

49

29381

1698842.96

... More
Supply of Switchgear unit consisting of 2/3 pole switch fuse unit along with programme 21 switches, fuses of suitable rating, meters, indications etc. of approved make and as per Central Railway practice. General arrangement to be approved by Engineer incharge. Make Siemens, L&T, or Havells. (Inspection by RDSO)

49

116424

6731635.68

... More
Resin cored wire as per specification No. IS:1921-1975 with Alloying element percentage as 63% SN (Tin) and / 37% Pb (Lead) with percentage of various impurities not exceeding 22 the values Sb (Antimony) 0.2% maximum , Cu (Copper) 0.1% maximum, As (Arsenic) 0.05% maximum, Fe (Iron) 0.02% maximum & other impurities mainly Al, Zn & Cd shall be limited. The flux shall be free from corrosive action as per clause 5.2 & flux percentage may be used as per requirement. (Inspection by Consignee) 23

130

1252

192145.77

... More
Lacing thread rolls, black, wax coated (100 mtrs). (Inspection by Consignee)

350

66

27319.95

... More
Fabrication and supply of Board made of White sunmica sheet over 12 mm thick particle/laminated/ wooden board covered with 5 mm thick perspex transparent sheet in aluminium/ steel frame and Painting of SWR/Track insulation plan etc. (Inspection by Consignee)

4

7303

34472.61

... More
Design, fabrication and supply of Fuse Auto Changeover System for 32 Nos. of external non-deteriorating type fuses or 'G' type fuses from 0.6 Amp to 4 Amp capacities used in signalling circuits. System shall have 8 cards with monitoring arrangement of 4 fuses in one card. As per RDSO Spec. RDSO/SPN/209/2012 Ver.2.0 or latest amendment if any. (Inspection by RDSO)

160

4281636

5052331.42

... More
Design, fabrication and supply of Fuse Auto Changeover System for 24 Nos. of external non-deteriorating type or 'G' type fuses from 4 A to 10 Amp capacities generally used for point operaton circuits. System shall have 6 cards with monitoring of 4 fuses in one card. As per RDSO Spec. RDSO/SPN/209/2012 Ver.2.0 or latest amendment if any. (Inspection by RDSO)

12

486160

573669.46

... More
Supply of Main Signal Post 140 mm outer dia 3.6 Mtr Length as per spec No IRS S 6/81 with latest amendments. (Inspection by RITES)

22

6832

177364.43

... More
Supply of Main Signal Post 140 mm outer dia 4.6 Mtr Length as per spec No IRS S 6/81 with latest amendments. (Inspection by RITES)

40

6948

327969.2

... More
Supply of Main Signal Post 140 mm outer dia 5.6 Mtr Length as per spec No IRS S 6/81 with latest amendments. (Inspection by RITES)

15

9233

163431.18

... More
Supply of Shunt Signal Post with Base (GI Pipe of 80 mm Dia of min. 1 meter length.). (Inspection by RITES)

45

2711

143999.23

... More
Supply of Cast Iron Main signal surface base 140mm as per spec No IRS S-10 and Drg 31 No 2011/M with latest amendments, with CLS Ladder assembly complete for CLS signal 5.5/4.5/3.5 mtrs long as per RDSO Drg. No. SA-23156(Adv), SA-23153 (Adv) & SA-23150 (Adv) Alt. 1 respectively with Latest Amendment as the case may be for CLS unit & signal back staging as per extent C. Rly practice (Inspection by RITES)

82

9034

874141.45

... More
Supply of Cast iron Shunt signal surface base 80 mm as per spec No.IRS S 10 and Drg 32 No.2011/M with latest amendments, as per RDSO Drg No. SA-23156/Drg.No.RST/11413 as per extent C.Rly practice (Inspection by Consignee)

45

2071

110014.7

... More
Supply of Signal No.plates. as per Drg No RST-11393 / SK-842 (Inspection by Consignee)

90

521

55403.48

... More
OFF set bracket 5-1/2 " to suit 140 mm dia CLS Post with two no. of "U" Bolts with nut & washer complete as per RDSO Drg.No.SA-23080 for Signals & Routes (Inspection by Consignee)

30

999

35390.8

... More
Supply of A/AG/C/P/G/IB Board as per Drg. RST-11444/1(A), RDSO Drg No SA 23460(AG), SA-23461( C), RST-11445. SA 23456(P), SA 23477(G) & SA 23476-77(IB) as applicable respectively with Latest Amendment. (Inspection by Consignee)

55

561

36456.93

... More
Supply of Stop Board as per RST-11791 (STOP BOARD)/ RDSO Drg No.7235/B as per extent C.Rly practice. (Inspection by Consignee)

11

3340

43354.63

... More
Supply of different warning Boards as per Block section limit Board RDSO Drg.No. SA 2373 Paint and retroreflective arrangement as per Railways drawing. (Inspection by Consignee)

9

3252

34536.98

... More
Supply of Hand Cuff Locks/ Godrej Navtal lock with Three common keys. (Inspection by Consignee)

340

286

114823.44

... More
Supply of 2 Aspect signal unit in FRP body without lences & transformer as per Drg. No. 39 SA-23003 A/M Alt-S or latest & RDSO Spec. No. RDSO/SPN/194/2006 Rev. 2.0 or latest & complete & to suit LED Signal lamps and suitable for 140 mm post saves pigment finish on the backside of the and inside, white pigment finish inside the 2-aspect unit to avoid any extra paint cost. (Inspection by RITES)

28

30939

1022238.11

... More
Supply of 3 Aspect Signal unit in FRP body without lences & transformer as per Drg. No. 40 SA-23002 A/M Alt-S or latest & RDSO Spec. No. RDSO/SPN/194/2006 Rev. 2.0 or latest complete & to suit LED Signal lamps and suitable for 140mm post saves pigment finish on the backside of the and inside, white pigment finish inside the 3 Aspect unto to avoid any extra paint cost. (Inspection by RITES)

13

31708

486415.91

... More
Supply of 4-aspect signal unit in FRP body without lences & transformer as per Drg. No. 41 SA-23001 A/M Alt-S or latest RDSO Spen No. RDSO/SPN/194/2006 Rev.2.0 or latest complete & to suit LED Signal lamps and suitable for 140 mm post saves pigment finish on the backside of the and inside, white pigment finish inside the 4-aspect unit to avoid any extra paint cost. (Inspection by RITES)

28

41024

1355451.46

... More
Supply of Shunt Signal position light type FRP complete as per RDSO Specification No. 42 RDSO/SPN/194/2006 Ver 2.0 or latest with offset bracket 3-1/2" to be fitted on 140mm post as per drawing No. SA-23840 (Adv) Alt-2 for dependent type complete without signal unit bracket, terminals, lenses, lamp, lamp holder, and to suit LED Signal lamps. (Inspection by RITES)

45

13950

740759.34

... More
Supply of 1-way junction Route Indicator to FRP body without lenses and transformers as per RDSO Drg. No. SA-23401 with latest Alteration & as per RDSO Specification No. RDSO/SPN/194/2006 Rev.2 or latest complete & to suit LED Signal lamps. (Inspection by RITES)

8

35033

330714.35

... More
Supply of 2-way junction Route indicator in FRP body without lenses and transformers as Per RDSO Drg. No. SA-23402 with latest Alteration & as per RDSO Specification No. RDSO/SPN/ 194/2006 Rev. 2 or of latest complete & to suit LED Signal Lamps. (Inspection by RITES)

12

44432

629157.12

... More
Supply of 3-way junction Route Indicator in FRP body without lenses and transformers as per RDSO Drg. No. SA-23403 with latest Alteration & as per RDSO specification No. RDSO/SPN/194/2006 Rev.2 or latest complete & to suit LED Signal Lamps. (Inspection by RITES)

3

45194

159988.95

... More
Supply of 4-way junction Route Indicator in FRP body without lenses and transformers as per RDSO Drg. No. SA-23404 with latest Alteration & as per RDSO specification No. RDSO/SPN/194/2006 Rev.2 or latest complete & to suit LED Signal Lamps. (Inspection by RITES)

2

49751

117413

... More
Supply of "Calling On" Signal Unit in FRP body without lenses and transformers as per RDSO Specification RDSO/SPN/194/2006/Rev.2.0 or latest complete and to suit LED sigal Lamps. (Inspection by Consignee) 48 220.00 Numbers 5250.48 1155105.60 18.00 1363024.61

50

8669

511515.25

... More
Supply of Phenolic 10mm thick sheet, grade P3 in standard size of 1.22X1.22 Mtr as per spec. No IS 2036 of 1995. (Inspection by RITES)

-

-

48

... More
Supply of ARA Terminal blocks with links made of PBT Specn No.IRS/75/2006(Rev-2) with latest amendments and RDSO Drg.No.SA-23741A Alt.4, SA-23745 Alt.5, SA-23746, SA-23748 Alt.4 & SA-23756A Alt.3. (Inspection by RITES)

66000

72

5654866.8

... More
Supply of cartridge fuse block made of PBT as per RDSO Drg No SA-23748 Alt 4, SA- 23749 & Spec No IRS S 75/2006 with latest amendment. Fuse block shall be suitable for round head type voltage fuses. (Inspection by RDSO)

800

162

153815.36

... More
Supply of round head type non detoriating type low voltage cartridge fuse as per Specn No IRS/S/78/92 with latest amendments 2A/4A/6A capacity (Inspection by Consignee)

1700

70

140680.78

... More
Supply of Tik-tak, piano type switches,5 A (as per IS Specification). (Inspection by Consignee)

290

33

11432.9

... More
Supply of three pole plug and socket 5 Amp (as per IS Specification). (Inspection by Consignee) 54

290

230

79000.29

... More
Supply of Lamp 110V/24W, 2 Pin for Loc. (Inspection by Consignee)

450

22

12069.63

... More
Supply of Apparatus Case with godown locks with detachable handle on both the doors. - Single Case as per Drg. No.SK 783-1 & 2 with latest alteration. (Inspection by RITES)

170

16020

3213622.03

... More
Supply of Apparatus Case with godown locks with detachable handle on both the doors. - Half Case as per Drg. No.SK 783-1 & 2 with latest alteration. (Inspection by RITES)

85

12853

1289250.18

... More
Supply of earth electrode assembly as per Drg.No. CR/S&T/SK-815 (Inspection by RDSO)

360

1078

457968.38

... More
A CLASS EARTHING- Supply of ESR ALTEC TERRA STREAMER Lightning Arrester with SS adaptor (TSP30, 50 Mtr. Radius) SPN: NFC-17-102-2011. (Inspection by RDSO)

6

62877

445169.44

... More
Supply of Lighting Strike recorder LSC 6 digit shall be weather proof type.It should 59 have 6 digit event count & the capacity to count smallest strike(3 KA).It should be voltage sensing type counter.So that it will register nearly strikes & static discharge due to induction effect as per IS 2309:1989 (Inspection by Consignee)

7

14747

121817.32

... More
Maintenance Free Earth as per RDSO/SPN.197/ 2008 or latest consisting of : 1) Copper 60 bond steel electrode 3 Mtr long 17mm dia with copper bonding thickness of min. 250 micron & UL listed & marked-01 No. 2) Earth enhancement compound RDSO Approved in sealed bag of 10 Kgs - 03 No. 3) Copper strip 150 x 25 x 6mm - 02 No. 4) Copper strip 300 x 25 x 6mm - 01 No. 5) 35 Sqmm Copper Cable to connect earth electrode to MEEB - 15 Mtr Approx. (Inspection by RDSO)

58

17786

1217296.43

... More
Supply of 35 Sq.mm Multistrand Single Core PVC Insulated Copper for connecting earth bus bar to earth electrode. (Inspection by RDSO)

1600

406

767151.04

... More
Supply of Copper Tape 25x6 mm (Bonding ring conductor) mounted on insulated standoff (1 round). (Inspection by Consignee) 63

255

795

239335.86

... More
Supply of 300x25x6 mm Cu Equipotential Bus Bar. (Inspection by Consignee)

35

1334

55129.31

... More
Supply of Microprocessor based universal earth resistance sensing unit 12 channel AC/DC as per RDSO/SPN/256/2002 with latest amendments. (Inspection by RDSO)

26

145626

4467822.55

... More
Supply of Track Lead Juction Boxes as per C.Rly Drg. No.RST 11509 made from fiiber glass alongwith terminal blocks. (Inspection by RITES)

290

1047

358618.76

... More
Supply of B type choke to specn.No.IRS.S.65/83 (Amd.3) with latest amendments. (Inspection by RDSO)

160

3666

692206.88

... More
Supply of adjustable Track Feed Resistance disc type 7.5/15/30 ohms as per RDSO Drg. No. SA 20161-66/M (Adv) with latest amendments (with Phenolic moulded base). (Inspection by RDSO)

155

1288

235600.81

... More
Supply of Track feed battery chargers, 110V AC input 2, 4 to 6 V DC Output to Specn.No.IRS.89/2013 Ver.1.0 with latest amendments. Charger shall be suitable for charging 80 AH battery. (Inspection by RDSO)

145

2430

415824.33

... More
Supply of Channel Pins single groove, galvanised, 7 mm suitable for 4mm dia bonding wire as per spec No. IRS: S 17-75 Revision 3. (Inspection by Consignee)

6000

2

14230.8

... More
Supply of PVC jacketed wire rope for Track Lead connections. PVC jacketed wire rope 70 should be of Galvanised steel wire rope 6 mm dia (6x19 stranded wire with steel core of 6 mm dia) sheathed with PVC 2mm wall thickness, overall thickness being 10 mm. PVC sheath should be made of type 6 compound as per IS 5831 of 1984 Reaffirmed 2001 and steel wire rope as per IS: 2266:2019. Reclaimed or recycled material should not be used. (Inspection by Consignee)

3000

52

185106.6

... More
Supply of 8 SWG GI wire (4mm dia) suitable for track circuit rail bonding. As per IRS Specification S:13@45>46@ (Inspection by Consignee)

300

86

30734.28

... More
Supply of Hydrometer, Exide make or similar for measuring specific gravity of Battery Graded acid with mounting stand in location Boxes.Consignee inspection under manufacturer certificate. (Inspection by Consignee)

40

283

13387.81

... More
Supply, installation, testing and commissioning of Track Battery Charger Monitoring System for 2V/4V/6V/8V batteries with accessories at nominated stations. General Scheme to be approved by Engineer incharge. (Inspection by Consignee)

155

1667

304896.13

... More
Supply, installation, testing and commissioning of Remote Indication Unit along with all accessories for above item. (Inspection by Consignee)

8

843

7964.34

... More
Supply of Electronic Timers for DAC reset arrangement 3 sec to 30 sec with 2NO/2NC contact working voltage 24V/60V DC. Siemens/ABB/L&T or SELEC (642XA programmable electronic timer switch) make. (Inspection by RDSO)

240

2819

798420.1

... More
Supply of Pre-wired Crank Handle cum key lock relay box (of metal) alongwith LEDs, with approved type push buttons, 8-way terminal strips, string rod, etc. as per Drawing No.RST.C.114 (Inspection by Consignee)

3

10467

37055.27

... More
Supply of William stretcher nylon insulation set suitable for ground connection as per RDSO drg No T-10367, T-10368, T-10384 as applicable and to the spec IRS S 23 & 40/84 with latest amendements . (Inspection by Consignee)

120

531

75312.79

... More
Supply of Tongue attachment nylon insulation set consisting of one insulating plate as per Drg no: RST-106961 & 3 nos of Ferrules with collars to suite rodding supplied as per RDSO spec & Drg.no: RST-10692 (Inspection by Consignee)

120

338

47903.28

... More
Supply Gauge Tie plate nylon insulation as per RDSO drg No: T- 10372 Alt2, T- 10368, T- 10371 Alt2, T-15083/88/Alt2 & T-11690/Alt2 and to the spec IRS S 23 & 40 with amendement 01 or latest amendements. (Inspection by Consignee)

120

244

34565.98

... More
Supply of Ground connections, complete set suitable for IRS type/appd. point Machine for ordinary turnout with tounge attachment insulation and other insulation as per RDSO Drg. 80 S/3361@47>47?40@for IRS type point machine) or RDSO Drg No.SA-9151/52 (for Siemens point machine) with latest amendements. However the ground connection shall be procured only after confirmation from Railway engineer as per site condition /type of machine/turnout. (Inspection by RITES)

37

8171

356759.83

... More
Supply of GI pipe, inner dia. 100mm dia. B-class as per spec. No.IS 1239 PT. 1/2004 or latest with sockets and fittings. TATA/JINDAL/ZENITH BIRLA make. (Inspection by RITES) 82 10000.00 Metre 321.43 3214300.00 18.00 3792874.00 82

1600

1029

1943356.16

... More
Supply of DWC HDPE pipe with one snap fit coupler and 'O' ring fire resistant, anti rodent, in 6 meter length of size 120 mm outer dia as per RDSO/SPN/204/2011 Ver. 1.1 with Amd.1 or latest. (Inspection by RITES)

-

-

82

... More
Supply of RCC pipe half round of size 300mm dia outer and 250 mm dia internal 1 mtr long. matching to IS No.458/2003 amendment-1 with Rev.4. (Inspection by RITES)

12000

422

5979060

... More
Supply of RCC pipes half round of size 150mm dia outer and 100 mm dia internal 1 mtr long matching to IS No. 458/2003 amendment-1 with Rev.4. (Inspection by RITES)

2500

206

608113

... More
Supply of Modular terminal block of 2.5 sq.mm 2 in 2 out type disconnect type terminal 85 along with as per RDSO/SPN/189/2004 Rev 3.0. The current capacity of 16 Amps and more. The terminal should have marking at centre to view description from front. Material to be procured from RDSO approved firms only. (Inspection by RITES) 86

21500

117

2971334.4

... More
Supply of DIN Channel for the terminals 1 Mtrs each. (Inspection by Consignee) 87

350

216

89509.49

... More
Supply of End plates for modular terminal block. (Inspection by Consignee) 88

2100

23

57960.42

... More
Supply of End Clamp for modular terminal block. (Inspection by Consignee)

2100

16

41655.18

... More
Tool bag complete with Megger as per Annexure. ADD AC/DC clamp meter, with Hand Held Tool Bag. (Inspection by Consignee)

7

52213

431283.26

... More
Supply of Adhesive Tapes rolls, PVC (18mmx25Mtr) Steel Grip/SCOTCH/ANCHOR. (Inspection by Consignee)

210

33

8301.3

... More
Supply of Trans-receiver hand held 5 Watt Analog VHF Set along with two sets of OEM 91 approved rechargeable battery including one as spare, quick Battery Charger, Helical Antenna and Belt Clip conforming to RDSO specification no. RDSO/SPN/TC/107/2018 Rev 0.0 with amendment no.1 or later. (Inspection by Consignee)

21

13482

334088.92

... More
Supply of VHF 25W transreceiver (synthesised) set complete consisting of Analog Set as per CR specification. (Inspection by Consignee)

3

23800

84254.09

... More
Supply of 4.5 Kg CO2 type fire extinguisher alog with all accessaries, extinguisher testing certificate has to be supplied along with - Supply of ISI marked Carbon di Oxide type (BC) fire 93 extinguisher of 4.5 Kg capacity confirming to IS 2878:2004 from seamless cylinder, with IS marked control value, high pressure mtr., Long discharge hose and horn complete with initial gas charged with carrying handle and wall mounting braket etc., as required by Site Engineer. (Inspection by Consignee)

70

5019

414580.14

... More
Supply of Block proving by Digital Axle Counter as per RDSO/SPN/188/2004 with latest amendments using UFSBI for Single line BPAC working, RDSO SPN RDSO/ S-32016 or latest complete 94 as per RDSO spec. IRS S:105/2012 (Ver.0) or latest. One pair consists of following : Universal Fail Safe Block interface as per RDSO Spec. No.RDSO/SPN/147/2005 (latest amendments)-02 Nos. SM's Panel (RDSO/S/32019 latest amendment) with all accessories complete-02 Nos. Relay rack with due Locking and sealing arrangement duly wired (As per RDSO/S/32020- including relays)-02 Nos. Relays for double line section will be supplied with prewired relay rack. (Inspection by RDSO)

3

950509

3364805.05

... More
Supply of Block proving with Digital Axle Counter using UFSBI for Double line BPAC working, RDSO SPN RDSO/S-32012 Ver.1.0 or latest complete as per RDSO Spec.IRS S:105/2012 (Ver.0) or latest. One pair consists of following: Universal Fail Safe Block interface as per RDSO Spec. 95 No.RDSO/SPN/147/ 2005 (latest amendments) - 02 Nos. SM's Panel (RDSO/S/32017 Tentative) with all accessories complete-02 Nos. Relay rack with due Locking and sealing arrangement duly wired (As per RDSO/S/32018-Tentative)- 02 Nos Block Telephone with Accessories as per RDSO Specn No. RDSO/SPN/191/2006. Relays for double line section will be supplied with prewired relay rack. (Inspection by RDSO)

1

1320153

1557780.69

... More
"Supply of Single Section Digital Axle Counter (SSDAC) with two detection point with reset arrangement and vital relay box as per RDSO/SPN/177/2012 Ver.03 or latest. Each set consist of the following:- a) High frequency TX coil and RX coil (Each set consist of web mounting type TX coils-2 Nos. RX coils-2 Nos. along with 10 mtr cable-2 sets), b) Track side digital axle counter unit-2 Nos. c) 24V 6F/4B, 1000 ohm ""Q"" type relay box duly wired-2 Nos. d) Clamp with deflector plates and hardware etc-4 Nos. e) Reset Box-2 Nos. f) Mushroom/Location Box suitable for housing Track side 96 equipment(2 Nos). 2) Transportation, Installation, Testing & Commissioning:- Transportation, Installation, Testing & Commissioning of equipment field training (one man day per set) at site or as desired by Site Engineer. These includes:- a) Foundation and erection of Track side Equipment i.e. Mushroom/ Location Box(if required). This includes supply of all associated materials. b) Individual Earthing of all detecton Point for the OEM recommended earth value certified by OEM Site Engineer. This includes supply & installation of maintenance free earth materials and exothermic bonding and other connecting cable etc as per Railway practice (As per RDSO Spec. No. RDSO/SPN/197/2008 or latest. Resetting equipmet to be connected to the EI Ring earth. c) Installation to be carried out by OEM certified Engineer. 3) Tool Kit consisting of :- a) Digital True RMS multi meter of suitable make for aove Digital Axle Counter System with probe set-1 No. b) Train Simulator (High frequency)-1 No. c) Extender Card-1 No. d) Dummy wheel-1 No. e) Different type of spanners suitable for aove Digital Axle Couner- 1 Set. f) Torque wrenches suitable for the above-1 No. g) Screw driver set suitable for the above-1 Set. h) Carrying Bag for Tools-1 No. i) 6 Nos. Electrostatic Discharge Wrist Band for cards/ modules protection. (Inspection by RDSO)"

14

440628

7279190.75

... More
Supply of QNA1-K AC immunised relay, 8F-8B, 24VDC along with plug board, retaining clip and connectors conforming to BRS:931A & RDSO letter no.STs/E/Relays/ UEA/PI dated 30.05.97 Annexure-II IRS:S60, IRS:S34 & IRS:S23. (Inspection by RDSO)

340

4099

1644907.96

... More
Supply of QNA1 AC immunised relay, 8F-8B, 24 VDC along with plug board, retaining clip and connectors confirming to BRS : 931A, IRS:S60, IRS:S34 & IRS:S23 (Inspection by RDSO)

160

3852

727323.68

... More
Supply of QN1 Non AC immunized natural relay 8F-8B,24VDC along with plug board, retaining clip and connectors conforming to BRS:930A,IRS:S60,IRS:S34 & IRS:S23 .(Inspetion by RDSO)

195

4147

954440.99

... More
Supply of QSPA1 relay, 24VDC, slow to pick up, 8F-4B, along with plug board, retaining clip and connectors conforming to BRS:933A, IRS : S60, IRS:S34 & IRS:S23 (Inspection by RDSO)

175

4414

911683.05

... More
Supply of QTA2 AC immunised track relay, 9 Ohm, 2F.1B, along with plug board, retaining clip and connectors conforming to BRS:939A, 966 & Appendix F2, IRS:S34 & IRS:S23 (Inspection by RDSO)

160

3859

728734.02

... More
Supply of QBAT track Relay, AC immunised, 2F-2B contacts, 9 ohms. complete with plug board, retaining clip & connectors as per RDSO / SPN/84 Ver 2.0 or latest. (Inspection by RDSO)

35

6603

272736.53

... More
Supply of MODEM compatible with existing UFSBI system to work on back up media (either VF channel on OFC P/Mux or 2 Mbps E1 channel from STM or direct dark single mode optic fibre cable upto 30 Km distance). (Inspection by Consignee)

4

62499

294996.84

... More
Supply of Automatic media changeover of Modems working on redundant channels for data transmission on OFC/Quad/Microwave Radio. (Inspection by Consignee)

4

32526

153522.72

... More
Supply of Modems for UFSBI (For use with secondary media and OFC/Quad). (Inspection by Consignee)

4

65026

306923.81

... More
Supply of Key Lock Relay with different ward combinations (three extra set of ward plate for Point Machine to be supplied with each relay). Siemens Make working on 60V DC/24 DC or functional equivalent without base plates. RDSO/SPN/219/2016 Version 1.0 d 1. (Inspection by RDSO) 107 6.00 Numbers 67218.31 403309.86 18.00 475905.63

60

9145

647531.84

... More
Supply, Installation, Testing & Commissioning of Manual call points, complying to RDSO/SPN/217/2021 Ver 3 or latest. As per latest VDS approved/Listed.( Inspection by RDSO)

20

5226

123347.52

... More
Supply, Installation, Testing & Commissioning of Resettable, Analogue Type Linear Heat Sensing (LHS) Cable complying to RDSO/SPN/217/2021 Ver 3 or latest. As per latest UL or FM or VDS or LPCB approved/Listed.( Inspection by RDSO )

770

1414

1284878.52

... More
Supply, Installation, Testing & Commissioning of LHS Interface Module with all accessories for single stretch, complying to RDSO/SPN/217/2021 Ver 3 or latest. As per latest UL or FM or VDS or LPCB approved/Listed.( Inspection by RDSO )

17

134184

2691733.85

... More
Supply, Installation, Testing & Commissioning of Aspiration (Air Sampling Type) Detection Unit complying to RDSO/SPN/217/2021 Ver 3 or latest. As per latest UL or FM or VDS or LPCB approved/Listed.( Inspection by RDSO )

16

278360

5255443.79

... More
Supply, Installation, Testing & Commissioning of CPVC Pipe for Aspiration Detection System complying to RDSO/SPN/217/2021 Ver 3 or latest and shall be listed/approved by UL or FM or VDS or LPCB or tested with appropriate equivalent standard. ( Inspection by consignee )

450

1614

857411.01

... More
Supply, Installation, Testing & Commissioning of Analogue Addressable loop powered Monitor Module with inbuilt isolator complying to RDSO/SPN/217/2021 Ver 3 or latest. ( Inspection by RDSO)

17

8745

175442.95

... More
Supply, Installation, Testing & Commissioning of Analogue Addressable loop powered Control Module complying to RDSO/SPN/217/2021 Ver 3 or latest. ( Inspection by RDSO)

19

8745

196083.3

... More
Suppy,Installation,Testing & Commissioning of Hooter cum Strobe complying to RDSO/SPN/217/2019 Ver 3 or latest (Inspection by RDSO)

14

7748

128002.58

... More
Supply,Testing & Commissioning of 2C 1.5 sq mm twisted shielded armoured copper cable (Per Meter) with accessories complying to the RDSO/SPN/217/2021 Ver 3 or latest. ( Inspection by RDSO)

1000

113

133800.2

... More
Supply,Testing & Commissioning of Isolator Device to isolate te circuit in case of short circuit, complying to the RDSO/SPN/217/2021 Ver 3 or latest. ( Inspection by RDSO)

9

3721

39521.16

... More
Supply,Testing & Commissioning of Auto Telephone Dialler (GSM) to send then pre- recorded message to multiple mobile numbers, prorammed earlier, complying to the RDSO/SPN/217/2021 Ver 3 or latest. ( Inspection by RDSO)

7

9303

76846.83

... More
Fail safe Electronic Time delay unit (Plug in type) to operate 24V DC with only one fixed time setting of 30@47<47@120 seconds as per RDSO Specification No. IRS-S-61/2000 with Amendment No.3 or Latest. (Inspection by RDSO) 120

21

3971

98416.25

... More
Supply of cable route marker as per RST/C/203 of FRP. (Inspection by Consignee)

550

202

131682.1

... More
"Design, maufacture and Supply of Electronic Interlocking (EI)system (Hot Standby) architecture complete as per RDSO specification No.RDSO/SPN/192/2019 Ver 2.0 / RDSO/SPN/203/2011 ver 1.0 with latest amendment or latest version or latest specifications. RDSO Technical Advisory Note No. STS/E/TAN/3012 Ver 2.0 dated 10.08.2016 or latest regarding Technical System Application Approval for Electronic Interlocking (EI) installations, STS/SSI/General dated 07.12.2018 TSAA as per the technical requirements and tentative approved Signalling Plans & Diagrams with OEMs specification. Electronic Interlocking (EI) system mainly consisting of Central Processsing Equipment, Interface Equipments and all types of required Relays, EI racks etc. as per requirements, dual operator Industrial Grade Embeded PC (as per Cl 5.3.2 of RDSO specification or 121 latest) with VDU panel (52"" LED 2 nos. or bigger) with Redundancy as per the RDSO technical advisory Note No. STS/E/TAN/3007 Version 1 dt. 02.112.12 or latest (Hot standby dual VDU Normally one system will be online and other system will be in standby mode), All types of required Relays suitable for EI, interconnecting cables and Jumper wires. It also includes provision of Industrial grade maintenance Terminals (as per Cl 5.3.2 and 7.2 of RDSO specification or latest) (42"" LED or Bigger with UPS minimum 2 hr back up), required power Supply DC-DC converters for EI equipments, Housing for EI equipments and enclosures, fuses, screw less disconnecting type terminals, fixture mounting arrangements and accessories necessary to make the EI system functional as per approved signalling plan. It does not include supply of Datalogger, however Protocol Convertor for Data logger to be supplied. The tenderer should furnish complete details of cards/modules/submodules connectors, relays etc, for each station. For system ""A & B segregation between the DC-DC converters should be made so that in case of failure only one system is affected. The system design shall incorporate details of approved SIP and its subsequent alteration/ modicication till its commissioning. It included supply of essential spares for El modules at 10%- Essential spares of the El equipments subject to minimum one of each type mainly consisting of processor, cards/module, interface relay etc. Item wise detailed breakup with unit and quantity to be provided in separate annexure. For 03 Huts (For 20 to 50 Routes)" (Inspection by RDSO)

30

627204

22203025.49

... More
"CENTRALISED EI Installation ,testing & commissioning of EI system complying to RDSO Technical Advisory Note No STS/E/TAN/3012 Ver 2.0 dated 10.08.2016 and Supply, Installation ,testing & commissioning of earthing arrangment for EI as per RDSO/SPN/197/2008 at locations 1 /Gumtis/Cabins/EI Huts/Auto Hut of the Yard, Earthing of EI equipment, relay racks and Power equipment etc to be done with Class A protection, Earthing shall be in the form of Perimetric/Ring Earth conforming to RDSO specification and RDSO technical advisory note for earthing and bonding scheme of EI No. STS/E/TAN/3006 Ver.1 Dt. 02.11.2012 or latest, with earth resistance less than 1 ohm. "

3

564158

1997122.15

... More
DISTRIBUTED EI:- Installation ,testing & commissioning of EI system complying to RDSO Technical Advisory Note No STS/E/TAN/3012 Ver 2.0 dated 10.08.2016 and Supply, Installation ,testing & commissioning of earthing arrangment for EI as per RDSO/SPN/197/2008 For Yard with " TWO OC", 2 With Class A protection at two locations/Gumtis/Cabins/EI Huts/Auto Hut of the Yard, Earthing of EI equipment, relay racks and Power equipment etc to be done with Class A protection, Earthing shall be in the form of Perimetric/Ring Earth conforming to RDSO specification and RDSO technical advisory note for earthing and bonding scheme of EI No. STS/E/TAN/3006 Ver.1 Dt. 02.11.2012 or latest, with earth resistance less than 1 ohm.

1

1449068

1709901.07

... More
Installation of Cable Termination Racks Assembly complete including wall supports, 3 scaffolding Disconnecting links/ARA terminal, 96 way tag block with tag block cover & other necessary accessories etc. The work shall be done as per approved plan, extant practice on C. Railways & the instruction of Rly engineer at site.

44

1306

67840.23

... More
Installation, wiring, testing and commissioning of Data logger complete along with 4 accessories with Contractors own wiring & fixing material as per following configuration. (It includes loading of NETWORKING software and networking of data logger. The requisite communication cable/channel for networking will be arranged by Railway. - 1024 digital & 32 analog inputs

7

21620

178582.52

... More
Wiring and charging of Integrated Power Supply System to signaling installation. This includes connection of MF Earth of 1 ohm earth resistance for IPS and power distribution connection to bus bars and relay racks in the room with contractor's own wiring materials and fabrication and fixing of AC/DC power distribution board made on 10mm thick Phenolic hylam sheets or any standard make with connections suitable for 63 A.Wiring to be done considering site requirement , depending upon the load with suitable wires,lugs & glands as per instructions of Engineer-in-charge. The item also includes supply & fixing of ladder along the wall for carrying power supply wires/cables from IPS room to Relay room/power room and potential free contact wiring at Datalogger IDF, etc.

7

31176

257520.2

... More
Lettering & Numbering of detail and description writing of particulars of terminations & equipments on relay rack, relays, cable termination rack, battery & power equipments, IPS, operating 6 panel, axle counter etc constituting entire system with contractor's own paint and writing material ("Asian/Dulux" make enamel paints to be used). This includes supply and fixing of teflon strips 3mm thick and 25 mm wide for each row of relays and cable terminations. The work shall be done as per extant practice on C.Rly & instruction of Rly engineer at site.

41

368

17826.58

... More
Preparation of cable route plan, cable coreage plan, location particulars, Cable termination rack particulars, cable meggering report, earth resistance particulars, Traction bonding diagram, 1/2 wire count sheet and any other drawing in Autocad in A3/A4 size.The contractor shall initially supply 3 sets of circuits complete for approval of Railways. Railways will return one set to the 7 contractor duly approved with alterations/corrections if any. The contractor shall incorporate Railways alterations/corrections in the tracings without any deviation and submit all tracings complete in all respects to the Railways . This includes submission of final cable route plan as per laid cable duly measured at every 30m clearly indicating distance of laid cable from fixed point of reference & indicating all track crossings and tail cables. This also include designing of cable coreage plan based upon I.P in consultation with engineer-in-charge. - For small/medium yards

3

24049

85136.5

... More
Excavation and Casting of Main signal foundation as per Drg No SK 801 with 8 contractor's own materials including cement and anchor bolts of standard size. The required scaffolding Ferma etc for Casting of foundation will have to be brought by the contractor at his own cost.

77

9149

831309.03

... More
Excavation and Casting of Shunt signal foundation as per Drg No SK 802 with 9 contractor's own materials including cement and anchor bolts of standard size. The required scaffolding Ferma etc for Casting of foundation will have to be brought by the contractor at his own cost.

25

2649

78151.99

... More
Erection of CLS Post with Surface base and signal unit on top or on OFF set Bracket, 10 fixing of front and back staging, ladder and guards, signal name plates/boards if any with contractors own brackets and fixing materials. This also includes erection of auxiliary signals like calling on, shunt signal if any. The work shall be done as per instructions of Rly engineer at site.

77

3490

317121.39

... More
Erection of shunt signal with Surface Base, Post, Signal unit and fixing of No.plates. The work shall be done as per instructions of Rly engineer at site. 12

25

481

14202.48

... More
Fixing of Jn.Route Indication 1-Way/2-Way/3-Way on the top of the signal post.

25

763

22529.15

... More
Fixing of Stop Board, Block section limit Board, goods warning board with contractors own material. The work shall be done as per instruction of Rly engineer at site.

11

553

7181.57

... More
Termination of tail cable on Main signal units and wiring with contractor own material, etc. The work shall be done as per instruction of Rly engineer at site.

77

1096

99607.09

... More
Termination of tail cable on Shunt signal units and wiring with contractor own material, etc. The work shall be done as per instruction of Rly engineer at site.

25

356

10508.78

... More
Installation of ON/OFF aspect LED's in signal including termination of tail cable on signal, wiring, fixing of LED units and testing. The work shall be done as per instruction of Railway Engineer at site.

225

545

144867.42

... More
Supply and fixing of Protective screen of expanded metal 12 SWG of size 1200 x 1500 mm on signals as per standard practice.

10

4319

50968.57

... More
Fabrication providing all fixtures as per Railway Drawing including fixing of PVC coated/with PVC pipe coveredand fixing of phenolic laminated/Fibre glass sheet in location box by string rods at the back side for cable support with contractor's own materials. The work shall be done as per drg and arrangement similar to SK 783-1&2. with latest alterations & as per instructions of Rly engineer at site. Single Case

170

2251

451697.04

... More
Fabrication and fixing of phenolic laminated/Fibre glass sheet in location box by 19 providing all fixtures as per Railway Drawing including fixing of PVC coated/with PVC pipe covered string rods at the back side for cable support with contractor's own materials. The work shall be done as per drg and arrangement similar to SK 783-1&2. with latest alterations & as per instructions of Rly engineer at site. Half Case

165

1984

386436.67

... More
Fixing of cutting in relay bases & wiring of relays with Contractors own material obtained from approved sources in location box as per the instuctions of Engineer in charge.

220

566

146995.9

... More
Fixing of ARA Terminals and fuse blocks on phenolic laminated sheets and fixing by stainless steel/brass nuts & bolts.This includes provision of two additional holes on the board on either side for cable conductor entry.

66000

927300

1094214

... More
Termination of cable cores on ARA terminal/fuse blocks in the apparatus Cases/ cable termination rack.This includes all associated works of pulling out the cable from underground. The work shall be done as per location plans and instructions of Rly engineer at site.

73000

772340

911361.2

... More
Excavation and Casting of Apparatus Case foundation with contractors Anchor bolts, cement, ballast and other materials. The required scaffolding Ferma etc for Casting of foundation will have to be brought by the contractor at his own cost. - Single Case as per Drg No . SK-803

170

9887

1983336.21

... More
Excavation and Casting of Apparatus Case foundation with contractors Anchor bolts, cement, ballast and other materials. The required scaffolding Ferma etc for Casting of foundation will have to be brought by the contractor at his own cost. - Half Case as per Drg No . SK-804

165

9693

1887408.17

... More
Erection of Apparatus Cases. This includes filling of location foundations and plastering - Single Case

170

1098

220266.82

... More
Erection of Apparatus Cases. This includes filling of location foundations and plastering - Half Case

165

842

164015.28

... More
Installation of Eqpt. (Relays, resistance, chargers batteries etc.as applicable) & wiring of the same in apparatus Cases as per location diagrams & circuit diagrams, as per Instruction of site incharge and practice - Single Case

170

1497

300442.63

... More
Installation of Eqpt. (Relays, resistance, chargers batteries etc.as applicable) & wiring of the same in apparatus Cases as per location diagrams & circuit diagrams, as per Instruction of site incharge and practice - Half Case

165

1017

198161.77

... More
Installation of earth electrode assenbly as per Drg.No.RE/S&T/SIG/Tender/SK726/85 including earth wire connected through GI wire 8 SWG supported on M.S. flat of size 6mm x 40 mm to earth electrode as per drg. No. CR/S&T/SK-815 for sigg. Equipment such as lever frames, apparatus 29 case, signals, relay racks,block insruments, and etc. as per RE manual. The earth value should be less than 10 Ohms including the lead wire. The value should be measured in presence of Rly. supervisor. It should be documented and painted on earth enclosure made of concrete.( only earth electrode will be supplied by Railway). All other material required for provision of earthing will be brought by the contractor.

360

2528

1073953.87

... More
Installation & commissioning of A-Class Lighning protection complete include base plate with base mast & accessories. SPN: NFC-17-102-2011 and as per IS 2309:1989. 31 58.00 Set 5290.34 306839.72 18.00 362070.87

6

19122

135383.9

... More
Installation of unit Earth as per RDSO/SPN/197/Ver.I or latest, to construct earthing of

-

-

31

... More
Connecting main earth electrode to BRC using 35 sq.mm copper cable.

1600

92

174809.92

... More
Installation of 25 x 6 mm copper tape (bonding ring conductors) mounted on insulated standoffs (1 round) 34

90

207

22049.24

... More
Installation of 300 x 25 x6 mm Cu equipotential Bus Bar.

35

441

18228.17

... More
Installation, wiring, testing & commissioning of Microprocessor baased universal earth leakage detector unit 12 channel AC/DC.

26

7411

227370.4

... More
Erection, Fitting and Rail connection of Track Lead Juntion Box on two 36 supports(M.S.angle) with contractor's fixing material and PVC jacketed wire for track lead connection including angles of size 40 x 40 x 5 mm 1200 mm length. This will include drilling of holes for track lead/side connections on rail. The work shall be carried out as per Drg. No. SK-845 or/& instructions of Rly engineer at site.

290

1305

446687.35

... More
"Provision of bonding with contractor's PVC jacketed wire rope for Track Lead connection. PVC jacketed wire rope should be of Galvanised steel wire rope 6mm dia (6 x 19 stranded 37 wire with steel core of 6 mm dia ) sheathed with PVC 2mm wall thickness, overall thickness being 10mm PVC sheath should be made of type 6 compound as per IS 5831 of 1984 Reaffirmed 2001 and steel wire rope as per IS:2266:2019. Reclaimed or recycled material should not be used. This will include drilling of 7.1mm dia holes in rails (4 Nos) and provision of two jumpers for each bond, clipping of bonds etc. with contractors own materials and tools as per instruction of Rly engineer at site."

290

169

58054.23

... More
Provision of bonding with GI wire 4mm dia ( 8 SWG) for track jumper & fish plate joints bonds. This will include drilling of 7.1mm dia holes in rails (4 Nos) and provision of two jumpers for each bond, clipping of bonds etc. with contractors own tools as per instruction of Rly engineer at site.

1040

160

196941.06

... More
"Installation of Axle counter(Digital)/Central Evaluator, wiring from CT rack to Central evaluator, installation and wiring of indoor & outdoor reset box and wiring the power supply including 39 supply of 2 core shielded cable of required size copper conductor as per IRS S 76/89 or IS 694/1977 as applicable with other accessories. NOTE : installation/programming/configuration/commissioning of Axle counter equipment to be carried out in accordance with latest guidelines issued by Railways/RDSO preferably by Authorised representative of OEM."

23

27340

742011.13

... More
"Installation of EJB and Track devices of Digital Axle Counter including digging of trench, drilling of holes,if required on rail , laying of Doubled walled antirodent corrugated pipe, 40 Medium class from track device to location box and making its terminations. ( DWC pipe made up of High density Polyethylene of 60mm outer dia of suitable length and all other accessories as per site requirement to be supllied by firm.) NOTE : Installation/programming/configuration/commissioning of Axle counter equipment to be carried out in accordance with latest guidelines issued by Railways/RDSO preferably by Authorised representative of OEM."

26

15731

482645.79

... More
Fixing of track devices ( Transmitter coil and receiver coil ) to the rails , fixing of EJB in 41 the location ,connection of track device to EJB using DWC pipe of suitable length and wiring of EJB ,testing and adjustment of transmitter and receiver to obtained required channel level as per standard practices on C.Rly. and instructions of Rly Engineer on site . Per 42 70.00 Detection 2890.19 202313.30 18.00 238729.69 Point (DP)

26

13436

412217.4

... More
Installation, wiring & testing / commissioning of Multi Section Digital Axle Counter's Central Unit/Evaluator/Processor for the section /at station including its associated all indoor equipments, indication panel, monitoring console/interface computer and wiring the same to integrate with the relay circuits including supply of required power cable of multi -strand 10 Sq mm or more from power room to Central Evaluator, 2 core shielded cable of required size copper conductor as per IRS (S) 76/89(Amd.3) or IS 694/2010 with latest amendment as applicable with other accessories as per the instructions of Railway Engineer at site and earthing as per OEM's technical requirement and specifications. This also includes laying & termination of cable if any from Panel Room to Axle Counter room /Relay room in DWC pipe with contractor's material / existing ladder.

-

-

42

... More
Installation, wiring & testing / commissioning of Axle Counter's Reset Box of all types in 43 Cabin/Panel room and wiring the same to integrate with the Axle counter as per the instructions of Railway Engineer at site. This includes laying & termination of cable if any form Panel Room/Axle Counter room /Relay room to Reset Box in DWC pipe / existing ladder.

5

7655

45166.68

... More
Installation, Fixing and wiring of track side Electronic Equipment of Axle counters including its battery & charger (if required), foundation and earthing as per OEM's technical 44 requirement and specification associated Relays in apparatus cases, location huts, relay rooms etc., with contractor's wiring material, termination of tail cables on terminals/fuse blocks. Supply and making Axle counter Parameter History Cards, all activities as per standard practice and technical specifications. Per 45 60.00 Detection 956.92 57415.20 18.00 67749.94

26

16824

516181.8

... More
Supply, fixing & wiring of mismatch panel depcting Indication Panel/VDU layout with contractors own material like LEDs for each track section, flexible wire, connecting terminals, buzzer etc. The work shall be done as per extant practice on C.Rly. & instruction of Rly. Enginer at site.

3

50121

177429.44

... More
"Fixing of point machine on newly laid turnout o n Wooden/MBC sleepers , fixing of ground connections, adjustment and testing with crank handle operations,Removal of ground 47 connection & point machines duly numbered. This will include fixing of bend pipes with welded frame for cable entry to machine. This will also includes necessary adjustment and smithy work, drilling of holes to tounge rails, fitting of insulation for tounge attachment, gauge plate & stretcher bars, cable termination & wiring if required. The work shall be done as per extant practice on C. Rly & the instruction of Rly engineer at site."

37

3526

153979.65

... More
Installation, fixing and wiring of Boxes for Key Lock Relays with contractor's wiring and fixing material.The work shall be done as per extant practice on C. Rly & the instruction of Rly engineer at site.

18

3119

66255.84

... More
"Excavation of cable trench as per cable route plan,1.0 mt. deep and 300mm wide along side the track in normal soil/strata, conforming to distances as per cable route plan and refilling after cable laying. This work includes covering of cable laid in trench by loose soil for a layer of 50mm 49 thickness after clearing of route,bushes etc. It shall be ensured that top of the cables laid is at a depth of 0.8m or more. It if is less, then the width and depth shall be suitably increased and accordingly proportionate payment shall be made. In case depth of trench is not achievable due to site conditions proportionate payment will be made as per procedure. The work shall be done as per the extant practice on Central Railway and instructions of Railway Engineer at site. Drg. No. SK 805"

7500

350

3097500

... More
"Excavation of cable trench as per cable route plan,1.0 mt. deep and 300mm wide along side the track in hard soil, conforming to distances as per cable route plan and refilling after cable laying. This work includes covering of cable laid in trench by loose soil for a layer of 50mm 50 thickness after clearing of route,bushes etc. It shall be ensured that top of the cables laid is at a depth of 0.8m or more. If it is less, then the width and depth shall be suitably increased and accordingly proportionate payment shall be made. In case depth of trench is not achievable due to site conditions proportionate payment will be made as per procedure. The work shall be done as per the extant practice on Central Railway and instructions of Railway Engineer at site. Drg. No. SK 805"

600

583

412997.64

... More
"Cutting of all types of Roads/ platforms (except concrete type) for trenching and 51 excavation to depth of 300mmx300mm wide approx. and refilling after laying of RCC/GI /DWC pipe & to restore them to original condition. The work shall be done as per extant practice on C.Rly & instructions of Rly engineer at site. Drg. No. SK 807" 52 1600.00 Metre 69.97 111952.00 18.00 132103.36

200

2916

688334.12

... More
Fixing of GI pipes for crossing the culverts, bridges etc. and concreting of ends with brick masonry at both ends as per the instruction of Rly engineer at site.

-

-

52

... More
Digging of trench 1.0 M deep from rail flange/road level (for LC) and 0.3Mtrs. to 0.6 53 Mtrs wide and back filling after placing of DWC/RCC/GI pipe.(Placing of DWC/RCC/GI pipe covered separately. The ballast disturbed be screened and dressed as required by Engineer-in-charge or his representatives and road tarred immediately. Drg. No. SK 806

440

583

302864.94

... More
Laying of DWC/RCC pipes alongwith collars/RCC Half round pipes in trenches at places of track and road crossings, platform cuttings etc. 55

37000

56

2482071

... More
Laying of signalling/Power/Telecom cable of various cores/sizes in trenches.

580

5197

3557114.25

... More
Placing and securing of cable route markers in trenches at the specified interval and at diversions, joints etc along the cable route. The work shall be done as per extant practice on C Railways & the instruction of Rly engineer at site.

550

12

8131.97

... More
Wherever depth of 0.5M cable trench is not feasible, cable shall be protected as under:- Preparation of cement mixture 1:3:6 with contractor's own materials and spreading cement concrete mixture layer of 100 mm thick over the already laid cables in the excavated trench.

180

5329

1131996.42

... More
Fixing of modular terminal/fuse blocks alongwith all accessories with provision of fixing 58 holes on hylam sheets/side angles of Loc Box and fixing by galvanised nuts & bolts. This includes fixing of DIN channel alongwith PVC Comb type 'C' channel (size 2 inch x 2 inch) for cable termination on modular terminal. The PVC channel with cover to be supplied by firm as required. The work shall be done as per the instruction of Rly engineer at site.

22500

19

505777.5

... More
Termination of cable cores on ARA terminal / Disconnecting link/fuse blocks, in the 59 Apparatus cases/cable termination rack. This includes all assosiated works of pulling out the cable from under underground. The work shall be done as per location plans and instructions of Rly engineer at site.

56500

7

473357

... More
Transferring of signalling/Telecom cables from existing location box to New location box. The work include breaking/dismantling of existing foundation of locations, excavating and removing /segregating coils of this cables which may be of about 10 mtr in length .These cables are then to be disconnected and removed from the existing locations one by one as per the instructions and under the supervision of railway staff present at site. The cable is then to be inserted and 60 terminated in new location box. The item includes neatly dressing of cables marking wiring tree etc. The material required for dressing /lacing will be arranged by contractor at its own cost. The work is required to be done systematically and with due precaution during the night block of 2.00-2.30 hrs each or within the time that may be allowed. The excavation work to be done carefully without damaging the cables to avoid undue failures. (Termination charges will be given separately) Note: Proportionate payment will be made if cable is of other length. 2/6/12/19/24/30 core signalling cable/4 or 6 Quad/PIJF/Any Signalling/Telecom Cable(One no. unit= One cable of 10 m length).

30

472

16712.34

... More
Painting two coats of synthetic enamel paint over one coat of Red Oxide primer after scrapping and cleaning of the surface wherever necessary with contractor own supply of primer and 61 paints over all outdoor gears including lifting barrier, axlecounter, ground frame, point machine, location boxes, signal post, unit, track circuits etc The work shall be done as per extant practice on C Rly & the instructions of Rly engineer at site. (Paints to be used shall confirm to relevant IS spec.). This includes Lettering / Numbering Termination particulars, equipment names etc. legibly and neatly inside and outside surface of units, boxes etc.- for small stations.

3

23283

82421.96

... More
"Painting of two coats of synthetic enamel paint over one coat of primer on the following after scraping & cleaning surface wherever necessary with contractor' own supply of 62 paints.Wherever required contractor shall apply coating of epoxy paint also as per instructions of site- in-charge.Epoxy paint will be supplied by Railways. NOTE:- The paint and primer should be from M/s Asian paints Co. Ltd.,. The paints will be primer (IS 5660 of 1970) the Aluminium synthetic black enamel (IS 2932 of 1974) brilliant white and yellow Painting two coats of enamel paint over one coat of primer. - Apparatus Case Full Size."

170

435

87349.26

... More
"Painting of two coats of synthetic enamel paint over one coat of primer on the following after scraping & cleaning surface wherever necessary with contractor' own supply of paints.Wherever required contractor shall apply coating of epoxy paint also as per instructions of site- in-charge.Epoxy paint will be supplied by Railways. NOTE:- The paint and primer should be from M/s Asian paints Co. Ltd.,. The paints will be primer (IS 5660 of 1970) the Aluminium synthetic black enamel (IS 2932 of 1974) brilliant white and yellow Painting two coats of enamel paint over one coat of primer. - Apparatus case Half Size."

115

326

44372.54

... More
"Painting of two coats of synthetic enamel paint over one coat of primer on the following after scraping & cleaning surface wherever necessary with contractor' own supply of paints.Wherever required contractor shall apply coating of epoxy paint also as per instructions of site- 64 in-charge.Epoxy paint will be supplied by Railways. NOTE:- The paint and primer should be from M/s Asian paints Co. Ltd.,. The paints will be primer (IS 5660 of 1970) the Aluminium synthetic black enamel (IS 2932 of 1974) brilliant white and yellow Painting two coats of enamel paint over one coat of primer. - Main Signal Post with Signal Units, Surface base and complete fittings as per Central Railways standard practice."

80

756

71456.08

... More
"Painting of two coats of synthetic enamel paint over one coat of primer on the following after scraping & cleaning surface wherever necessary with contractor' own supply of paints.Wherever required contractor shall apply coating of epoxy paint also as per instructions of site- 65 in-charge.Epoxy paint will be supplied by Railways. NOTE:- The paint and primer should be from M/s Asian paints Co. Ltd.,. The paints will be primer (IS 5660 of 1970) the Aluminium synthetic black enamel (IS 2932 of 1974) brilliant white and yellow Painting two coats of enamel paint over one coat of primer. - Shunt signal post with signal unit, surface base as per Central Railway's Standard Practice."

30

180

6395.36

... More
"Painting of two coats of synthetic enamel paint over one coat of primer on the following after scraping & cleaning surface wherever necessary with contractor' own supply of 66 paints.Wherever required contractor shall apply coating of epoxy paint also as per instructions of site- in-charge.Epoxy paint will be supplied by Railways. NOTE:- The paint and primer should be from M/s Asian paints Co. Ltd.,. The paints will be primer (IS 5660 of 1970) the Aluminium synthetic black enamel (IS 2932 of 1974) brilliant white and yellow Painting two coats of enamel paint over one coat of primer. - Track lead Junction Box. (Black enamel outside only)"

300

89

31590.96

... More
"Painting of two coats of synthetic enamel paint over one coat of primer on the following after scraping & cleaning surface wherever necessary with contractor' own supply of paints.Wherever required contractor shall apply coating of epoxy paint also as per instructions of site- 67 in-charge.Epoxy paint will be supplied by Railways. NOTE:- The paint and primer should be from M/s Asian paints Co. Ltd.,. The paints will be primer (IS 5660 of 1970) the Aluminium synthetic black enamel (IS 2932 of 1974) brilliant white and yellow Painting two coats of enamel paint over one coat of primer. - Point Machine with ground connections complete (Point Machine with Black enamel only outside and ground connections with Red Oxide)"

102

156

18808.66

... More
"Painting of two coats of synthetic enamel paint over one coat of primer on the following after scraping & cleaning surface wherever necessary with contractor' own supply of 68 paints.Wherever required contractor shall apply coating of epoxy paint also as per instructions of site- in-charge.Epoxy paint will be supplied by Railways. NOTE:- The paint and primer should be from M/s Asian paints Co. Ltd.,. The paints will be primer (IS 5660 of 1970) the Aluminium synthetic black enamel (IS 2932 of 1974) brilliant white and yellow Painting two coats of enamel paint over one coat of primer. - Axle Counter devices."

70

107

8883.63

... More
Lettering / Numbering of Signals, Point Machine, Track Lead Junction Boxes, Block Joints, Apparatus Cases etc. (each item to be taken as One Unit) This work will be carried out as per the standard practice being followed in Central Railway.

962

56

64295.46

... More
Lettering / Numbering Termination particulars, equipments names etc., legibly and neatly inside location boxes. - Full Case.

170

263

52864.12

... More
Lettering / Numbering Termination particulars, equipments names etc., legibly and neatly inside location boxes. - Half Case.

115

150

20359.07

... More
Installation, testing & commissioning of the 25 W VHF system including the erection of Mast, Antenna, charging of the battery with all Contractor's materials.

3

8626

30537.46

... More
Dismantling/Releasing of the existing outdoor signalling items such as CLS unit withposts alongwith base, lever frames (5 levers set), battery box with equipments, location box with equipments, block instruments, point machines, mechanical point, AFTC/DAC, Relay rack, CT Rack alongwith Relay rack. IDF with all accessories. All these unit will be counted as one no. along with their accessories. This includes the cost of transportation of released material from site to Railway Scrap Depot.

325

1177

451575.09

... More
Releasing of cables from old location boxes and taking it into new location boxes. This includes excavating the earth to release the cables from old location box for taking it into new location. This also includes releasing the old location box and bringing it to nearest station / central cabin.

35

2197

90744.77

... More
Transportation of signaling material/equipments including loading and unloading in 75 10MT vehicle, anywhere to anywhere, and stacking at destination as per instructions of SSE in-charge as per inventory. For carrying heavy materials like cable drums, DG set, Electrical Lifting barrier pedestal, IPS, Batteries, Point machine etc.

3500

53

222607

... More
Loading, un-loading & transportation of material from the Stores of SSE (Sig) depot or any other nominated place & vice-versa.

1000

5

5994.4

... More
Horizontal boring of cable duct of minimum 2.0 Mtr. depth alongwith laying of 120mm HDPE pipe for track crossing with minimum depth reckoned from the bottom of the rail/road crossing with minimum depth reckoned from ground level. The work shall be done as per extant practice & 77 instructions of site Engineer. Prepration of site for Horizondal boring shall be carried out in presence of Railway Representative. HDPE will be supplied by Railways. Note:- Contractor shall provide all material required for boring and adequate nos. of labours for proper laying of cables into the bore. Cable shall be laid cautiously so that it should not get damage due to rough handling & pressure on cable.

5800

2610

17865988.24

... More
"Design and supply of Detailed Signalling Circuits including Panel diagram(if required) , Route section Plan , Selection Table , Fuse & Negative Tag. Analysis , Contact analysis , Relay Rack Arrangement and wire count sheets etc. in A3 size.Completion circuit shall be plotted in AutoCAD. The contractor shall initially supply 2 sets of circuits duly signed by the circuit designer having substantial experience on design side for making such circuits, complete for approval of Railways. Railways will 78 return one set of circuit to the contractor duly approved with alterations /corrections, if any. The contractor shall incorporate Railway's alterations/corrections in the original tracings & CD without any deviation and submit two copies of the modified circuits. Original tracings so modified & final CD complete in all respects alongwith 6 sets of final approved circuits (out of which one set shall be supplied in transparent bags. Only two sheets of circuits shall be placed in one bag each ) shall be submitted to the Railways in case there are no further alteration suggested by Railways. This also includes modification in yard. - for major yards and stations having more than 200 routes"

1

1091997

1288556.77

... More
Design and supply of Detailed Signalling Circuits including Panel diagram(if required) , Route section Plan , Selection Table , Fuse & Negative Tag. Analysis , Contact analysis , Relay Rack Arrangement and wire count sheets etc. in A3 size.Completion circuit shall be plotted in AutoCAD. The contractor shall initially supply 2 sets of circuits duly signed by the circuit designer having substantial experience on design side for making such circuits, complete for approval of Railways. Railways will 79 return one set of circuit to the contractor duly approved with alterations /corrections, if any. The contractor shall incorporate Railway's alterations/corrections in the original tracings & CD without any deviation and submit two copies of the modified circuits. Original tracings so modified & final CD complete in all respects alongwith 6 sets of final approved circuits (out of which one set shall be supplied in transparent bags. Only two sheets of circuits shall be placed in one bag each ) shall be submitted to the Railways in case there are no further alteration suggested by Railways. This also includes modification in yard. - for stations having <50 routes

4

120592

569197.64

... More
"Preparation of final ammonia prints of diagrams in A-3 size after tracings are approved by Railways, in four sets for final submission with one set of diagram in transparent 80 polythene bag/lamination (only two sheets shall be placed in one polythene bag/laminated each). Every set shall be set in a plastic folder of A3 size and of good quality. The final approved tracings will be handed over to contractor by railway for this purpose and contractor will return back the same after taking out the prints for stations having less than 20 routes. - For major yards and stations having more than 200 routes"

5

55522

327582.75

... More
"Installation & commissioning of Block Proving with Digital Axle Counter as per RDSOspecification no. IRS: S-105/2012 using UFSBI & Block panel for Single/Double Line operation. (Unit-one pair Qty. 1 set)."

3

72794

257693.03

... More
Installation, Testing and commissioning of complete block Equipment., Universal Fail Safe Block Interface (Multiplexer), wiring in relay room, panel room for single line operation system as per technical specification. (UFSBI equipment will be supplied by Railway).

3

19476

68947.84

... More
Charging of 2V Lead Acid Batteries with contractors own battery grade sulphuric acid 83 and distilled water with minimum two charge - discharge cycles, installation of charged batteries in groups & their connection & wiring. The work shall be done as per extant practice of C.Rly & instruction of Engineer-in-charge.Detailed measurements of initial charging shall be recorded jointly by contractor & Rly's site-in-charge.

360

75

32229.58

... More
Wiring,Fixing & commissionig of modular of fuse 0.6 to 4 Amp rating alarm system having change over arrangement and potential free contact witing at Datalogger IDF Etc as per instruction of Railway Engineer (Module of 32 nos fuses)

160

103499

122129.06

... More
Wiring,Fixing & commissionig of modular of fuse 4 to 10 Amp rating alarm system having change over arrangement and potential free contact witing at Datalogger IDF Etc as per instruction of Railway Engineer (Module of 24 nos fuses)

12

7749

9144.95

... More
Installation, testing and commissioning of Automatic Media Changeover of modems working on redundant channels for data transmission on OFC / Quad(Unit - one Pair Qty 1 Set)

49

26752

1546802.37

... More
Distributed Architecture - Design, manufacture and supply of Hot standby Distributed Architecture Electronic Interlocking (EI) system complete as per RDSO specification No. RDSO/SPN/192/2019 ver-2 with latest amendment and RDSO Technical Advisory Note No. STS/E/TAN/ 3012 dt 10.08.16 or latest regarding technical system application approval for Electronic Interlocking installation as per technical requirement & tentative approved signalling Plans & Diagrams. Electronic Interlocking (EI) System mainly consisting of Central Processing Equipment, Interface equipment/Relays suitable for RE Etc. as per requirement, Modems, software & other interface cards, Interconnecting cables, Dual (Embeded Industrial grade fanless PCs of rugged & reliable type with suitable compact flash disc memory space) VDU panels(72" LED with minimum resolution 1920 * 1080 ) with redundancy (Hot standby dual VDU Normally one system online & other system will be in standby mode). All interfacing Relays (compatible to RE)(for all relays plus 20% spare) suitable for EI, interconnecting cable and jumper wires, Industrial grade maintenance Terminal (55" LED or bigger with UPS minimum 02 hrs back up), required power supply DC-DC converters for EI equipments which are not the part of IPS, Housing of EI Equipment & Enclosures, fuses, screw less disconnecting type terminals fixtures mounting arrangements and accessories necessary to make the EI system functional as per approved ( or tentative approved) signalling plan. Supply of protocol converter for datalogger as per Engineer in charge, the tenderer should furnish the complete details of cards modules, sub modules connectors, relays etc. for complete EI system with OC. system has 25% spare ports to accommodate additional input/ output and I/O cards for minor alterations in future with provision for accommodating additional 25% of logics bits spares/ timer spare in each CIU/ Card file level for facilitating / minor alterations. For system A & B segregation between DC/DC converters should be made so that in case of failure only one system is affected. the system design shall incorporate details of approved SIP and its subsequent/ alterations/ modification till its commissioning of EI which is shown in Red colour in the attached copy of tentative SIP with TWO number of OC. The tenderer must furnish complete details of cards / modules / sub modules connectors etc. for complete EI system (Appx Bit. 952) Jalgaon Station (Inspection by RDSO) Housing of EI Equipment & Enclosures, fuses, screw less disconnecting type terminals fixtures mounting arrangements and accessories necessary to make the EI system functional as per approved ( or tentative approved) signalling plan. Supply of protocol converter for datalogger as per Engineer in charge, the tenderer should furnish the complete details of cards modules, sub modules connectors, relays etc. for complete EI system with TWO OC system has 25% spare ports to accommodate additional input/ output and I/O cards for minor alterations in future with provision for accommodating additional 25% of logics bits spares/ timer spare in each CIU/ Card file level for facilitating / minor alterations. For system A & B segregation between DC/DC converters should be made so that in case of failure only one system is affected. the system design shall incorporate details of approved SIP and its subsequent/ alterations/ modification till its commissioning of EI for signalling gears of NGN Station as Annexure with two number of OC for approximate 1293 Bits. (Inspection by RDSO)

-

-

1

... More
Installation, testing and commissioning of Earthing arrangement for EI as per RDSO/SPN/197/2008 or latest. Earthing shall be in the form of ring earth confirming to RDSO Drawing 2 issued as per Rly. Board letter's No. 2010/SIG/SGF/EI (Ansaldo) dt 26.06.11 and RDSO Technical Advisory note for Earthing and Bonding scheme of EI No. STS/E/TAN/3006 Ver. 1 made dt 02.11.2012 or latest.. Note - this will also coverer the earthing & necessary protection of EI Equipment, as per detail given in the scope of work and pre commissioning check list of EI system. The earthing schematic shall be got approved from RDSO/ competent authority .

3

99157

297471.27

... More
Maintenance and supervision of EI system installed EI items of SCH C I (for Jalgaon Station and JL-BDI ABS Section) for one year as per details given in Special Condition of Contract, Technical requirement & SEM. Unit Year= EI/Year

1

396371

396371.69

... More
Fabriction finishing erection of VDU wooden console for fixing of VDU (wall mounted type, reset box, block instrument & other accessories related to operation of train for station masteras 4 per instruction of site engineer. NOTE: Semi decagon shape table of require size of hight suitable for comfortable operation of VDU fitted with open/cover shelf/drawer arrangment for fixing of operating VDU / telephone, terminal box/reset box/DLBI/SLBI/UFSBI & other arrangment of any other requirment of S&T/Optg Dept., all the materials and sundry item, for fabriction of console are to be supplied by contractor. (Inspection by Consignee)

1

82902

82902

... More
Supply of Steel Cupboard (plain storwel) size 6' X 3' Godrej Make (Inspection by Consignee)

6

13127

78767.7

... More
Supply of Panel operator/Relay room Chair model PCH - 7001 (Godrej) (Inspection by Consignee)

13

12518

162743.88

... More
Supply of Panel operator/Relay room record table model T - 102 (Godrej) (Inspection by Consignee) 4

6

14757

88544.88

... More
Supply of Chair model PCH - 7003 (Godrej) (Inspection by Consignee)

6

8977

53867.82

... More
Supply of Steel stools Godrej make model No ST2 or equivalent of same make (Inspection by Consignee)

9

2072

18655.47

... More
Supply & installation of 42 U Rack with FAN, make HCL, APW, Rittal, President or similar. (Inspection by Consignee)

7

51511

360580.36

... More
Preparation and supply of interlocking plan on the basis of approved engineering plan. 7 The contractor shall initially supply one print of IP duly signed by the designer and submit for approval of Railway. Railway will return one set of SIP duly approved with alterations/correct if any. The contractor after due corrections will submit 04 prints of SIP for approval, if any, the contractor will submit final tracing, CD and foour copies of IP to the Railway. Up to 50 Route

1

23285

23285.34

... More
Preparation and supply of interlocking plan on the basis of approved engineering plan. 8 The contractor shall initially supply one print of IP duly signed by the designer and submit for approval of Railway. Railway will return one set of SIP duly approved with alterations/correct if any. The contractor after due corrections will submit 04 prints of SIP for approval, if any, the contractor will submit final tracing, CD and foour copies of IP to the Railway. 51 Route to 75 Route

2

32987

65975.14

... More
Providing road breaker /concrete breaker with compressor and jack hammer for railway work such as cutting and dismentilling of road concrete /Bricks pucca structure (RCC/Steel section) including contractor's fuel, driver and all other charges completed as directed by Engg in charge.

100

1483

148350

... More
Supply of Tool Kit for maintenance of Multi Section Digital Axle Counter (MSDAC) consists of service test panel including Meter for testing of track equipments as per manufacturing specifications. (Tool kit should be suitable for maintenance of MSDAC supplied) (Inspection by Consignee) a) Torque wrench with reversible ratchet with 19 mm socket b) Screwdriver small No. 22 10 (Taparia) - 1 NO. c) Nut driver 13mm - 1 No. d) Fix spanner 16x17 - 1 No. e) Fix spanner 10x11 - 1 No. f) Fix spanner 8x9 - 1 No. g) Nose plier 1430 (Taparia) - 1 No. h) Nose plier (Taparia mini)- 1 No. i) IC cutter MT 10 Multitech - 1 No. j) Wire stripper 15OP Multitech - 1 No. k) Combination plier (Taparia) - 1 NO. l) Screw driver (Taparia) size-T 20L - 1 No. m) Soldering Iron - 1 No. n) Soldering wire - 1 No. o) Tool Box with Lock & key p) Dummy Wheel q) Card Puller r) Marking Jig-52 Kg/60Kg s) Measuring Card t) Fluke Meter 289.

2

190868

381737.74

... More
Supply of Earth Resistance tester dual range 10/100 ohms, digital display with complete earth testing kit. Motwane DET20 or similar (Inspection by Consignee)

6

6825

40950

... More
Supply of digital multimeter with AC/DC clamp, three & three forth digit model Meco 3690 Auto or similar other make (Inspection by Consignee)

6

3900

23400

... More
Supply of Insulation resistance tester with3-3/4 digital display suitable for 100 V Kusum Mecco KM01 or Rish Insu MIT 30 (Inspection by Consignee)

6

8482

50895

... More
Supply of True RMS Multimeter Fluke Make model 289 or similar. (Inspection by Consignee)

6

78000

468000

... More
Supply of Digital earth clamp tester for measurement of earth resistance. Make - 15 Motwane Model DECT-3/ FLUKE Model-1630/ MECO Model-4680 B/ KYORITSU Model-4200. Generalized Specilication for Portable Drtal Earth Clamp Meter is as under:- SN. Parameters Characteristics l.Resistance measurement range--O.Ol Ohm to l2OO Ohm. 2.Current Measurement Range--0 to 2O A, 3.Display--4 digrts 9999 count LCD, 4.Resolution Range--O.OO1 Ohm to 30 Ohm,5.Accuracy-+/-( I percent+o.ol Ohmlto +/-125 percent +30 Ohml,6.Conductor size -- 23mm approx / 35mm approx,T.Jaw size- 65mm x 32mm, 8.Instruction manual-To be provided, 9.Computer interface - RS 232,US8, lO.Environmental - Working temperature: O deg to 50 deg, Humidity less than 85 percent RH. ll.Memory Storage Facility-99 records 9[illoop resistance with no inductive, external magnetic field-- <50 A/m,9[ii]External Electric Field- < L Y /m, lo.Power Source-6 v DC l4x1.S V AA alkaline batteryl,l2.Single measurement / Sampling time- 0.5 second, l3.Sound and light enunciator - Beep sound, Flashing Symbol, AL Key to turn on - off and setting the sound and light alarm, l4.Over [,oad Indicator- -"OL" on display, l5.Overload Protection - itOA [Continuous],200A[5 sec], 16.Low battery indication- Display Symbol, 1 7. Range Selection-Auto, 18,Single Measurement time-O.S sec (Inspection by Consignee)

3

55264

165792.21

... More
Supply of DC-module along with Dc-Dc converter 110 v to 24-32 V/5 & 12-28 V/5 Amp or any suitable for IPS available at per site requirement 50% each(12-28 & 24-32) (Inspection by RDSO).

30

15283

458500.8

... More
Supply of DC-module along with Dc-Dc converter 110 v to 24-40 V/5Amp (for Axle Counter) or any suitable for IPS available (Inspection by RDSO).

30

15283

458500.8

... More
Fixing of DC-DC converter module and change in internal woring of IPS to suit DC-DC converter ( Note : Unit to treated as DC-DC converter)

60

6457

387453

... More
Installation, Testing and commissioning of Solid state Block proving by Axle Counter for 19 single line. This includes following items:1) Installation, Testing & Commissioning of Station Master's Block Panel - 02 Nos. 2) Installation, Testing & Commssioning of Micropercessor based SSBPAC[D] - 02 Nos. 3) Installation, Testing & Commissioning of Automatic Media changeover of modems, Leased line Modem etc. as per instruction of site engineer.

2

87516

175032

... More
Supply & Installation of Modular Power Supply Arrangement for VDU (42"-85") and Industrial PC (Embedded PC) with Input and Output Redundancy Arrangement and Hot Plugable Modules. 01. Insput O-Ring Diod Module with Potential Free-1 No contacts Per

3

250250

750750



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.