Central Railway Tender

Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.

Central Railway - CR Tender

Works
Electrical and Electronics
Electrical Works
Ireps
Opening Date21 Jan 2025
Closing Date14 Feb 2025
Tender Amount₹ 5,66,19,353.49 
Notes
Download

Costs

Summary

Supply, Installation, Testing And Commissioning Of Outdoor Signalling Equipment At Panvel In Connection With Work Of Panvel Kalamboli Coaching Terminus I In Mumbai Division Of Central Railway

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply of QTA2 AC immunised track relay, 9 Ohm, 2F.1B, along with plug board, retaining clip and connectors conforming to BRS:939A, 966 & Appendix F2, IRS:S34 & IRS:S23 (Inspection by Consignee)

115

4323

497145

... More
Supply of QBAT track Relay, AC immunised, 2F-2B contacts, 9 ohms. complete with plug board, retaining clip & connectors as per RDSO / SPN/84 Ver 2.0 or latest. (Inspection by Consignee)

10

7396

73962.4

... More
Supply of Main Signal Post 140 mm outer dia 4.6 Mtr Length as per spec No IRS S 6/81 with latest amendments. (Inspection by Consignee)

15

7782

116734.8

... More
Supply of Main Signal Post 140 mm outer dia 5.6 Mtr Length as per spec No IRS S 6/81 with latest amendments. (Inspection by Consignee)

20

10341

206828.2

... More
Supply of Shunt Signal Post with Base (GI Pipe of 80 mm Dia of min. 1 meter length.). (Inspection by Consignee)

25

3037

75931.75

... More
Supply of Cast Iron Main signal surface base 140mm as per spec No IRS S-10 and Drg 9 No 2011/M with latest amendments, with CLS Ladder assembly complete for CLS signal 5.5/4.5/3.5 mtrs long as per RDSO Drg. No. SA-23156(Adv), SA-23153 (Adv) & SA-23150 (Adv) Alt. 1 respectively with Latest Amendment as the case may be for CLS unit & signal back staging as per extent C. Rly practice (Inspection by Consignee)

35

10118

354137.35

... More
Supply of Cast iron Shunt signal surface base 80 mm as per spec No.IRS S 10 and Drg No.2011/M with latest amendments, as per RDSO Drg No. SA-23156/Drg.No.RST/11413 as per extent C.Rly practice (Inspection by Consignee)

25

2320

58011.5

... More
Supply of Signal No.plates. as per Drg No RST-11393 / SK-842 (Inspection by Consignee)

60

584

35057.4

... More
OFF set bracket 5-1/2 " to suit 140 mm dia CLS Post with two no. of "U" Bolts with nut & washer complete as per RDSO Drg.No.SA-23080 for Signals & Routes (Inspection by Consignee)

20

1119

22394.2

... More
OFF set bracket 3-1/2' for signals & routes. Drawing No. SA 23840 (Adv) Alt-2 as per extent C. Rly practice. (Inspection by Consignee)

20

5930

118605.8

... More
Supply of A/AG/C/P/G/IB Board as per Drg. RST-11444/1(A), RDSO Drg No SA 23460(AG), SA-23461(C), RST-11445. SA 23456(P), SA 23477(G) & SA 23476-77(IB) as applicable respectively with Latest Amendment.

10

629

6291.5

... More
Supply of Stop Board/IB Board as per RST-11791 (STOP BOARD)/ RDSO Drg No.7235/B as per extent C.Rly practice. (Inspection by Consignee)

10

3740

37409.2

... More
Supply of different warning Boards as per Goods Warning Board (SK-784). RDSO Drg N o . SA 2380 (Adv), SA 2370/M, Block section limit Board RDSO Drg.No. SA 2373 Paint and retroreflective arrangement as per Railways drawing. (Inspection by Consignee)

4

3642

14569.28

... More
Supply of Hand Cuff Locks/ Godrej Navtal lock with Three common keys. (Inspection by Consignee)

150

320

48081

... More
Supply of "2 Aspect" Signal Unit in FRP body without lenses and transformers as per 18 RDSO Specification RDSO/SPN/194/2006/Rev.2.0 or latest complete and to suit LED signal Lamps and suitable for 140 mm dia post Saves pigment finish on the back side of the and inside. White Pigment finish inside the 2 aspect unit to avoid any extra paint cost. (Inspection by RDSO)

25

34652

866303.5

... More
Supply of "3 Aspect" Signal Unit in FRP body without lenses and transformers as per 19 RDSO Specification RDSO/SPN/194/2006/Rev.2.0 or latest complete and to suit LED signal Lamps and suitable for 140 mm dia post Saves pigment finish on the back side of the and inside. White Pigment finish inside the 4 aspect unit to avoid any extra paint cost. (Inspection by Consignee)

6

35514

213084.42

... More
Supply of Shunt Signal Position Light Type FRP complete as per RDSO Specification 20 No.RDSO/SPN/ 194/2006/Rev.2.0 or latest with Off set bracket 3-1/2" to be fitted on 140 mm post drawing No. SA 23840(Adv) Alt-2 for dependent type complete with signal unit bracket, terminals etc without lenses, lamp, lamp holder, and to suit LED Signal lamps. (Inspection by Consignee)

6

15624

93745.8

... More
Supply of 1 way Junction Route Indicator in FRP body without lenses and transformers as per RDSO Specification RDSO/SPN/194/2006/Rev.2.0 or latest complete and to suit LED signal Lamps. (Inspection by Consignee)

5

39237

196186.5

... More
Supply of 2 way Junction Route Indicator in FRP body without lenses and transformers as per RDSO Specification RDSO/SPN/194/2006/Rev.2.0 or latest complete and to suit LED signal Lamps. (Inspection by Consignee)

10

49763

497638.4

... More
Supply of 3 way Junction Route Indicator in FRP body without lenses and transformers as per RDSO Specification RDSO/SPN/194/2006/Rev.2.0 or latest complete and to suit LED signal Lamps. (Inspection by Consignee)

-

-

23

... More
Supply of "Calling On" Signal Unit in FRP body without lenses and transformers as per RDSO Specification RDSO/SPN/194/2006/Rev.2.0 or latest complete and to suit LED sigal Lamps. (Inspection by Consignee)

10

9710

97101.2

... More
Supply of Phenolic 10mm thick sheet, grade P3 in standard size of 1.22X1.22 Mtr as per spec. No IS 2036 of 1995. (Inspection by RITES)

150

5880

882081

... More
Supply of ARA Terminal blocks with links made of PBT Specn No.IRS/75/2006(Rev-2) with latest amendments and RDSO Drg.No.SA-23741A Alt.4, SA-23745 Alt.5, SA-23746, SA-23748 Alt.4 & SA-23756A Alt.3. (Inspection by RDSO)

20000

81

1626400

... More
Supply of cartridge fuse block made of PBT as per RDSO Drg No SA-23748 Alt 4, SA- 23749 & Spec No IRS S 75/2006 with latest amendment. Fuse block shall be suitable for round head type voltage fuses. (Inspection by Consignee)

150

182

27373.5

... More
Supply of Tik-tak, piano type switches,5 A (as per IS Specification). (Inspection by Consignee)

150

37

5613

... More
Supply of three pole plug and socket 5 Amp (as per IS Specification). (Inspection by Consignee) 30

150

258

38784

... More
Supply of Lamp 110V/24W, 2 Pin for Loc. (Inspection by Consignee)

150

25

3819

... More
Supply of Apparatus Case with godown locks with detachable handle on both the doors.{ Note: Separate Locking arrangement from outside alongwith handle to be provided}

-

-

2602717.75

... More
Supply of earth electrode assembly as per Drg.No. CR/S&T/SK-815 (Inspection by Consignee)

200

1207

241490

... More
Supply of Microprocessor based universal earth resistance sensing unit 12 channel AC/DC as per RDSO/SPN/256/2002 with latest amendments. (Inspection by RDSO)

8

163101

1304813.92

... More
Supply of Track Lead Juction Boxes as per C.Rly Drg. No.RST 11509 made from fiiber glass alongwith terminal blocks. (Inspection by Consignee)

300

1173

352122

... More
Supply of B type choke to specn.No.IRS.S.65/83 (Amd.3) with latest amendments. (Inspection by RITES)

125

4106

513288.75

... More
Supply of adjustable Track Feed Resistance disc type 7.5/15/30 ohms as per RDSO Drg. No. SA 20161-66/M (Adv) with latest amendments (with Phenolic moulded base). (Inspection by Consignee)

125

1442

180340

... More
Supply of Track feed battery chargers, 110V AC input 2, 4 to 6 V DC Output to Specn.No.IRS.89/2013 Ver.1.0 with latest amendments. Charger shall be suitable for charging 80 AH battery. (Inspection by RDSO)

125

2721

340242.5

... More
Supply of Channel Pins single groove, galvanised, 7 mm suitable for 4mm dia bonding wire as per spec No. IRS: S 17-75 Revision 3. (Inspection by Consignee)

10000

2

22500

... More
Supply of PVC jacketed wire rope for Track Lead connections. PVC jacketed wire rope 39 should be of Galvanised steel wire rope 6 mm dia (6x19 stranded wire with steel core of 6 mm dia) sheathed with PVC 2mm wall thickness, overall thickness being 10 mm. PVC sheath should be made of type 6 compound as per IS 5831 of 1984 Reaffirmed 2001 and steel wire rope as per IS: 2266:2019. Reclaimed or recycled material should not be used. (Inspection by Consignee)

5000

58

292800

... More
Supply of 8 SWG GI wire (4mm dia) suitable for track circuit rail bonding. As per IRS Specification S:13@45>46@ (Inspection by Consignee)

10

97

972.4

... More
Supply of Hydrometer, Exide make or similar for measuring specific gravity of Battery Graded acid with mounting stand in location Boxes.Consignee inspection under manufacturer certificate. (Inspection by Consignee)

25

317

7942

... More
Supply, installation, testing and commissioning of Track Battery Charger Monitoring System for 2V/4V/6V/8V batteries with accessories at nominated stations. General Scheme to be approved by Engineer incharge. (Inspection by Consignee)

50

1867

93352.5

... More
Supply, installation, testing and commissioning of Remote Indication Unit along with all accessories for above item.

50

944

47246

... More
Supply of Electronic Timers for DAC reset arrangement 3 sec to 30 sec with 2NO/2NC contact working voltage 24V/60V DC. Siemens/ABB/L&T or SELEC (642XA programmable electronic timer switch) make. (Inspection by Consignee)

125

3157

394698.75

... More
Supply of Multi strand twin twisted core shielded cable of 28-30/0.2 mm for Axle counter as per IRS spec. 76/89 with latest amedments, if any. (Inspection by RITES) Numbers = Per 100 Meters

500

16758

8379435

... More
Supply of William stretcher nylon insulation set suitable for ground connection as per RDSO drg No T-10367, T-10368, T-10384 as applicable and to the spec IRS S 23 & 40/84 with latest amendements. (Inspection by Consignee)

90

595

53612.1

... More
Supply of Tongue attachment nylon insulation set consisting of one insulating plate as per Drg no: RST-106961 & 3 nos of Ferrules with collars to suite rodding supplied as per RDSO spec & Drg.no: RST-10692 (Inspection by Consignee)

90

378

34101

... More
Supply Gauge Tie plate nylon insulation as per RDSO drg No: T- 10372 Alt2, T- 10368, T- 10371 Alt2, T-15083/88/Alt2 & T-11690/Alt2 and to the spec IRS S 23 & 40 with amendement 01 or latest amendements. (Inspection by Consignee)

90

273

24606

... More
Supply of Ground connections, complete set suitable for IRS type/appd. point Machine for ordinary turnout with tounge attachment insulation and other insulation as per RDSO Drg. 49 S/3361@ 47>47?40@for IRS type point machine) or RDSO Drg No.SA-9151/52 (for Siemens point machine) with latest amendements. However the ground connection shall be procured only after confirmation from Railway engineer as per site condition /type of machine/turnout. (Inspection by RDSO)

80

9151

732150.4

... More
Supply of Ground connections,complete set suitable for IRS type/appd. point Machine 50 for derail switch with tounge attachment insulation as per RDSO Drg. S/3361@47>47?40@for IRS type point machine) or RDSO Drg No. SA 9151/52 with latest amendements. However the ground connection shall be procured only after confirmation from Railway engineer as per latest site condition /type ofmachine/turnout. (Inspection by Consignee)

10

7999

79994.7

... More
Supply of GI bend pipe, 'B' class, 50mm dia for cable entry in point machines, alongwith required fixing arrangements as per standard practice on Central Railway. As per Drg No. RST.11835. (Inspection by Consignee)

90

283

25479.9

... More
Supply of Point Machine Raised Bracket FRP make with cover as per Drg No.SK-846. (Inspection by Consignee)

90

984

88579.8

... More
Supply of GI pipe, inner dia. 100mm dia. B-class as per spec. No.IS 1239 PT. 1/2004 or latest with sockets and fittings. TATA/JINDAL/ZENITH BIRLA make. (Inspection by Consignee)

100

1152

115284

... More
Fabrication and supply of Board made of White sunmica sheet over 12 mm thick 54 particle/laminated/ wooden board covered with 5 mm thick perspex transparent sheet in aluminium/ steel frame and Painting of SWR/Track insulation plan etc. (Inspection by Consignee) Numbers = per Sq mtr.

5

9910

49554.4

... More
Supply of RCC pipes half round of size 150mm dia outer and 100 mm dia internal 1 mtr long matching to IS No. 458/2003 amendment-1 with Rev.4. (Inspection by Consignee)

500

238

119085

... More
Supply of RCC pipes half round of size 300mm dia outer and 250 mm dia internal 1 mtr long matching to IS No. 458/2003 amendment-1 with Rev.4. (Inspection by Consignee)

-

-

56

... More
Supply of Modular terminal block of 2.5 sq.mm 2 IN 2 OUT type disconnect type 57 terminal along with as per RDSO/SPN/189/2004 Rev 3.0. The current capacity of 16 Amps and more. The terminal should have marking at centre to view description from front. Material to be procured from RDSO approved firms only. (Inspection by RDSO) 58

8000

128

1030960

... More
Supply of DIN Channel for the terminals 1 Mtrs each. (Inspection by Consignee) 59

800

238

190784

... More
Supply of End plates for modular terminal block. (Inspection by Consignee) 60

800

25

20592

... More
Supply of End Clamp for modular terminal block. (Inspection by Consignee) 61

800

18

14800

... More
Supply of Marker Card as per customer spec. (10x10) (Inspection by Consignee)

800

92

73776

... More
Fuse terminal block with LED indication upto 2.5 sq.mm screw type one in one out (suitable for (400 mA, 630mA, 1A. 1.6A, 2A, 4A, 6.3A & 10A) as per RDSO/SPN/189/2004.(without fuse) (Inspection by Consignee) 63

800

200

160080

... More
End plate for through terminal block with LED indication. (Inspection by Consignee) 64

80

14

1199.2

... More
Fuse links of (400 mA, 630mA, 1A. 1.6A, 2A, 4A, 6.3A & 10A) (Inspection by Consignee) 65

800

47

37976

... More
Shorting link insulated Grey in colour. (Inspection by Consignee)

800

16

12984

... More
Operating tool (operating tool, screw driver & stripper) as per Annexure-VII. (Inspection by Consignee)

8

9529

76234

... More
Tool bag complete with Megger as per Annexure-VIII. ADD AC/DC clamp meter, with Hand Held Tool Bag. (Inspection by Consignee)

8

57453

459624.72

... More
Supply of Permanently Lubricated HDPE Telecom duct of size 50/42 mm and 68 accessories as per latest Specification TEC GR No. GR/TX/CDS-008/03/March 11 with latest amendment" for OFC cable of size 24 fibre armoured in length of 1000 mtrs/roll. Duct to be supplied from TEC approved sources. (Inspection by Consignee)

2

73040

146080.2

... More
Installation of Cable Termination Racks Assembly complete including wall supports, 1 scaffolding, Disconnecting links/ARA terminal, 96 way tag block with tag cover & other necessary accessories etc. The work shall be done as per approved plan, extant practice on C. Railways & the instruction of Rly engineer at site.

2

1205

2411.74

... More
Termination of cable cores on ARA terminal/disconnecting links in the cable termination 2 rack. This includes all assosiated works of pulling out the cable from under ground, peeling off insulation, dressing of cable core supported on sting rod with contractors own material. The work shall be done as per instructions of Rly engineer at site.

2500

9

24400

... More
Preparation of cable route plan, cable coreage plan, location particulars, Cable termination rack particulars, cable meggering report, earth resistance particulars, Traction bonding diagram, 1/2 wire count sheet and any other drawing in Autocad in A3/A4 size.The contractor shall initially supply 3 sets of circuits complete for approval of Railways. Railways will return one set to the 3 contractor duly approved with alterations/corrections if any. The contractor shall incorporate Railways alterations/corrections in the tracings without any deviation and submit all tracings complete in all respects to the Railways . This includes submission of final cable route plan as per laid cable duly measured at every 30m clearly indicating distance of laid cable from fixed point of reference & indicating all track crossings and tail cables. This also include designing of cable coreage plan based upon I.P in consultation with engineer-in-charge. For big yards (>100 routes)

1

60648

60648.01

... More
Excavation and Casting of Main signal foundation as per Drg No SK 801 with 4 contractor's own materials including cement and anchor bolts of standard size. The required scaffolding Ferma etc for Casting of foundation will have to be brought by the contractor at his own cost.

40

8443

337749.6

... More
Excavation and Casting of Shunt signal foundation as per Drg No SK 802 with 5 contractor's own materials including cement and anchor bolts of standard size. The required scaffolding Ferma etc for Casting of foundation will have to be brought by the contractor at his own cost.

25

2444

61123

... More
Erection of CLS Post with Surface base and signal unit on top or on OFF set Bracket, 6 fixing of front and back staging, ladder and guards, signal name plates/boards if any with contractors own brackets and fixing materials. This also includes erection of auxiliary signals like calling on, shunt signal if any. The work shall be done as per instructions of Rly engineer at site.

40

3221

128842.4

... More
Erection of shunt signal with Surface Base, Post, Signal unit and fixing of No.plates. The work shall be done as per instructions of Rly engineer at site. 8

25

444

11107.75

... More
Fixing of Jn.Route Indication 1-Way/2-Way/3-Way on the top of the signal post.

20

704

14096

... More
Fixing of Stop Board, Block section limit Board, goods warning board with contractors own material. The work shall be done as per instruction of Rly engineer at site.

10

510

5106.1

... More
Termination of tail cable on Main signal units and wiring with contractor own material etc. The work shall be done as per instruction of Rly engineer at site.

40

1011

40468.8

... More
Termination of tail cable on Shunt signal units and wiring with contractor own material etc. The work shall be done as per instruction of Rly engineer at site.

25

328

8219

... More
Installation of ON/OFF aspect LED's in signal including termination of tail cable on signal, wiring, fixing of LED units and testing. The work shall be done as per instruction of Railway Engineer at site.

40

503

20142.4

... More
Fabrication and fixing of phenolic laminated/Fibre glass sheet in location box by 13 providing all fixtures as per Railway Drawing including fixing of PVC coated/with PVC pipe covered string rods at the back side for cable support with contractor's own materials. The work shall be done as per drg and arrangement similar to SK 783-1&2. with latest alterations & as per instructions of Rly engineer at site.

-

-

305552.75

... More
Fixing of cutting in relay bases & wiring of relays with Contractors own material obtained from approved sources in location box as per the instuctions of Engineer in charge.

55

522

28741.35

... More
Excavation and Casting of Apparatus Case foundation with contractors Anchor bolts, cement, ballast and other materials. The required scaffolding Ferma etc for Casting of foundation will have to be brought by the contractor at his own cost. 18

-

-

1364224.5

... More
Erection of Apparatus Cases. This includes filling of location foundations and plastering

-

-

146106

... More
Installation of Eqpt. (Relays, resistance, chargers batteries etc.as applicable) & wiring of the same in apparatus Cases as per location diagrams & circuit diagrams, as per Instruction of site incharge and practice.

-

-

196259.75

... More
Installation of earth electrode assenbly as per Drg.No.RE/S&T/SIG/Tender/SK726/85 including earth wire connected through GI wire 8 SWG supported on M.S. flat of size 6mm x 40 mm to 20 earth electrode as per drg. No. CR/S&T/SK-815 for sigg. Equipment such as lever frames, apparatuscase, signals, relay racks,block insruments, and etc. as per RE manual. The earth value should be less than 10 Ohms including the lead wire. The value should be measured in presence of Rly. supervisor. It should be documented and painted on earth enclosure made of concrete.( only earth electrode will be supplied by Railway). All other material required for provision of earthing will be brought by the contractor.

200

2333

466634

... More
Installation, wiring, testing & commissioning of Microprocessor based universal earth leakage detector unit 12 channel AC/DC.

8

8172

65377.76

... More
Erection, Fitting and Rail connection of Track Lead Juntion Box on two 22 supports(M.S.angle) with contractor's fixing material and PVC jacketed wire for track lead connection including angles of size 40 x 40 x 5 mm 1200 mm length. This will include drilling of holes for track lead/side connections on rail. The work shall be carried out as per Drg. No. SK-845 or/& instructions of Rly engineer at site.

400

1204

481868

... More
Provision of bonding with GI wire 4mm dia ( 8 SWG) for track jumper & fish plate joints bonds. This will include drilling of 7.1mm dia holes in rails (4 Nos) and provision of two jumpers for each bond, clipping of bonds etc. with contractors own tools as per instruction of Rly engineer at site.

150

148

22216.5

... More
Drilling of holes of 16 mm dia as per instructions of Rly site incharge in rails using contractors own drilling equipments. Power supply for operating drilling equipments to be arranged by contractor.

300

38

11520

... More
"Installation of Axle counter(Digital)/Central Evaluator, wiring from CT rack to Central evaluator, installation and wiring of indoor & outdoor reset box and wiring the power supply including 25 supply of 2 core shielded cable of required size copper conductor as per IRS S 76/89 or IS 694/1977 as applicable with other accessories. NOTE : Installation/programming/configuration/commissioning of Axle counter equipment to be carried out in accordance with latest guidelines issued by Railways/RDSO preferably by Authorised representative of OEM."

20

25231

504633.2

... More
"Installation of EJB and Track devices of Digital Axle Counter including digging of trench, drilling of hoels,if required on rail , laying of Doubled walled antirodent corrugated pipe, 26 Medium class from track device to location box and making its terminations. ( DWC pipe made up of High density Polyethylene of 60mm outer dia of suitable length and all other accessories as per site requirement to be supllied by firm.) NOTE : Installation/programming/configuration/commissioning of Axle counter equipment to be carried out in accordance with latest guidelines issued by Railways/RDSO preferably by Authorised representative of OEM."

100

14518

1451839

... More
Fixing of track devices ( Transmitter coil and receiver coil ) to the rails , fixing of EJB in 27 the location ,connection of track device to EJB using DWC pipe of suitable length and wiring of EJB ,testing and adjustment of transmitter and receiver to obtained required channel level as per standard practices on C.Rly. and instructions of Rly Engineer on site Per

100

12399

1239984

... More
Installation, wiring & testing / commissioning of Axle Counter's Reset Box of all types in 29 Cabin/Panel room and wiring the same to integrate with the Axle counter as per the instructions of Railway Engineer at site . This includes laying & termination of cable if any form Panel Room/Axle Counter room /Relay room to Reset Box in DWC pipe / existing ladder.

1

7064

7064.98

... More
Installation, Fixing and wiring of track side Electronic Equipment of Axle counters including its battery& charger (if required), foundation and earthing as per OEM's technical requirement and specification associated Relays in apparatus cases, location huts, relay rooms etc., with contractor's wiring material, termination of tail cables on terminals/fuse blocks. Supply and making Axle counter Parameter History Cards, all activities as per standard practice and technical specifications.

100

15527

1552718

... More
Installation of complete assembly of track device/double rail contact unit for entry or exist with conductors all material including drilling of required sizes holes on rails for fixing these, taking the cable lead through anti-rodent, anti-oxidnat & non-flame propagating type Double walled 31 corrugated (DWC) pipe as pr RDSO/SPN/204/2011 Ver.1.1 with Amd.1 or latest from track device to location box and terminating it on terminals including digging of trench under track and upto location/Track side unit and all other accessories as per site requirement for laying of transmitter and receiver cable with suitable wire embeded rubber pipe with clamp for protecting these cables at DP end. Numbers= Per track device/double rail contact Per

20

11135

222719.8

... More
Supply, fixing & wiring of mismatch panel depcting Indication Panel/VDU layout with 33 contractors own material like LEDs for each track section, flexible wire, connecting terminals, buzzer etc. The work shall be done as per extant practice on C.Rly. & instruction of Rly. Enginer at site. Numbers = Per Sations

1

46255

46255.96

... More
Fixing of point machine on newly laid turnout o n Wooden/MBC sleepers , fixing of ground connections, adjustment and testing with crank handle operations,Removal of ground 34 connection & point machines duly numbered. This will include fixing of bend pipes with welded frame for cable entry to machine. This will also includes necessary adjustment and smithy work, drilling of holes to tounge rails, fitting of insulation for tounge attachment, gauge plate & stretcher bars, cable termination & wiring if required. The work shall be done as per extant practice on C. Rly & the instruction of Rly engineer at site. (Number = Per T/O)

10

3254

32548

... More
Installation, fixing and wiring of Boxes for Key Lock Relays with contractor's wiring and fixing material.The work shall be done as per extant practice on C. Rly & the instruction of Rly engineer at site.

10

2878

28788.3

... More
"Excavation of cable trench as per cable route plan,1.0 mt. deep and 300mm wide along side the track in normal soil/strata, conforming to distances as per cable route plan and refilling after cable laying. This work includes covering of cable laid in trench by loose soil for a layer of 50mm 36 thickness after clearing of route,bushes etc. It shall be ensured that top of the cables laid is at a depth of 0.8m or more. It if is less, then the width and depth shall be suitably increased and accordingly proportionate payment shall be made. In case depth of trench is not achievable due to site conditions proportionate payment will be made as per procedure. The work shall be done as per the extant practice on Central Railway and instructions of Railway Engineer at site. Drg. No. SK 805"

600

323

193806

... More
"Excavation of cable trench as per cable route plan,1 mt. deep and 300mm wide along side the track in hard soil, conforming to distances as per cable route plan and refilling after cable laying. This work includes covering of cable laid in trench by loose soil for a layer of 50mm thickness 37 after clearing of route,bushes etc. It shall be ensured that top of the cables laid is at a depth of 0.8m or more. If it is less, then the width and depth shall be suitably increased and accordingly proportionate payment shall be made. In case depth of trench is not achievable due to site conditions proportionate payment will be made as per procedure. The work shall be done as per the extant practice on Central Railway and instructions of Railway Engineer at site. Drg. No. SK 805"

150

538

80751

... More
"Cutting of all types of Roads/ platforms (ecxcept concrete type) for trenching and 38 excavation to depth of 300mmx300mm wide approx. and refilling after laying of RCC/GI /DWC pipe & to restore them to original condition. The work shall be done as per extant practice on C.Rly & instructions of Rly engineer at site. Drg. No. SK 807"

50

2691

134587

... More
Fixing of GI pipes for crossing the culverts, bridges etc. and concreting of ends with brick masonry at both ends as per the instruction of Rly engineer at site.

300

64

19374

... More
Digging of trench1.0 M. deep from rail flange/road level (for LC) and 0.3Mtrs. to .6 Mtrs wide and back filling after placing of DWC/RCC/GI pipe.(placing of DWC/RCC/GI pipe covered separately). The ballast disturbed be screened and dressed as required by Engineer-in-charge or his representatives and road tarred immediately. Drg. No. SK 806

-

-

40

... More
Laying of DWC/RCC pipes alongwith collars/RCC Half round pipes in trenches at places of track and road crossings, platform cuttings etc. 42

2500

52

131150

... More
Laying of signalling/Power/Telecom cable of various cores/sizes in trenches.

500

4796

2398295

... More
Placing and securing of cable route markers in trenches at the specified interval and at diversions, joints etc along the cable route. The work shall be done as per extant practice on C Railways & the instruction of Rly engineer at site.

250

11

2890

... More
"Wherever depth of 0.5M cable trench is not feasible, cable shall be protected as under:- Preparation of cement mixture 1:3:6 with contractor's own materials and spreading cement concrete mixture layer of 100 mm thick over the already laid cables in the excavated trench."

100

4918

491854

... More
Fixing of modular terminal/fuse blocks alongwith all accessories with provision of fixing 45 holes on hylam sheets/side angles of Loc Box and fixing by galvanised nuts & bolts. This includes fixing of DIN channel alongwith PVC Comb type 'C' channel (size 2 inch x 2 inch) for cable termination on modular terminal. The PVC channel with cover to be supplied by firm as required. The work shall be done as per the instruction of Rly engineer at site.

8000

17

140640

... More
Termination of cable cores on ARA terminal / Disconnecting link/fuse blocks, in the 46 Apparatus cases/cable termination rack. This includes all assosiated works of pulling out the cable from under ground. The work shall be done as per location plan and instructions of Rly engineer at site.

8000

6

52400

... More
Laying of GI pipes in on bridges/culverts/concrete drain/mountain ridges etc. with 47 suitable GI bend shall be provided where there is turning of pipe as per the instruction of Site engineer. GI clamps at every 2m as shown in the drawing to be fixed. Suitable holes to be made in the pipe before laying as per the instruction of the site engineer 10mm dia Drg. No. SK 808.

100

132

13247

... More
Laying of GI pipes inside the excavated trench in rocky area /less depth area as per 48 instructioin of Site engineer. GI clamps at every 2m as shown in the drawing to be fixed. Suitable GI Bend/Coupling and holes to be made in the pipe before laying as per the instruction of the site engineer

100

67

6757

... More
REMOVAL OF PSC/Wooden SLEEPERS coming in the way of/route of cable trenching, signal/location foundation/Track crossing etc. These obstruction will be removed by contractor for ensuring proper execution of related works.

200

129

25998

... More
REMOVAL of Redundant/old railscoming in the way of/route of cable trenching, signal/location foundation/Track crossing etc. These obstruction will be removed by contractor for ensuring proper execution of related works.

200

130

26086

... More
Termination of Tail cable inside the point machine through bend pipe. This includes preparatory works of pulling the cables, and peeling out the insulation, dressing and lacing after 51 termination etc., pulling of tail cable as per circuit requirement inside point machine through bend pipe, termination of cables on terminal blocks as per instruction of site supervisor. The cable shall be entered in such a way that, armouring shall protect the cable near sharp edge of entry point and armouring shall be clamped between pipe fixing bracket and body of point machine.

90

356

32046.3

... More
Shifting of existing Full Location Boxes coming in the alignment of doubling. The work includes loosing & removal of soil around location boxes by excavating soil around foundation, making of pit for shifting of location box horizontally opposite to railway track up to 0.5 to 1.0 mtr. This 52 includes loosing of existing cable coils without any damage. The excavated soil shall be back filled after shifting of Locaion Boxes. Location box along with its foundation shall be shifted by push method with the help of jacks or by crane by contractors own expenditure under instructions of engineer in- charge at site. Any minor repairs in foundation due to patching shall also be carried out by contracor as per instruction of Engineer incharge. The work may affect train working hence the work shall be done as per margin only or during traffic block only.

10

5027

50275.5

... More
Shifting of existing Half Location Boxes coming in the alignment of doubling. The work includes losing & removal of soil around location boxes by excavating soil around foundation, making of pit for shifting of location box horizontally opposite to railway track up to 0.5 to 1.0 mtr. This 53 includes loosing of existing cable coils without any damage. The excavated soil shall be back filled after shifting of Locaion Boxes. Location box along with its foundation shall be shifted by push method with the help of jacks or by crane by contractors own expenditure under instructions of engineer in- charge at site. Any minor repairs in foundation due to patching shall also be carried out by contracor as per instruction of Engineer incharge. The work may affect train working hence the work shall be done as per margin only or during traffic block only.

5

4049

20245.8

... More
Transferring of signalling/Telecom cables from existing location box to New location box. The work include breaking/dismantling of existing foundation of locations, excavating and removing /segregating coils of this cables which may be of about 10 mtr in length .These cables are then to be disconnected and removed from the existing locations one by one as per the instructions and under the supervision of railway staff present at site. The cable is then to be inserted and 54 terminated in new location box. The item includes neatly dressing of cables marking wiring tree etc. The material required for dressing /lacing will be arranged by contractor at its won cost. The work is required to be done systematically and with due precaution during the night block of 2.00-2.30 hrs each or within the time that may be allowed. The excavation work to be done carefully without damaging the cables to avoid undue failures. (Termination charges will be given separately) Note: Proportionate payment will be made if cable is of other length. 2/6/12/19/24/30 core signalling cable/4 or 6 Quad/PIJF/Any Signalling/Telecom Cable(One no. unit= One cable of 10 m length).

5

435

2178.45

... More
Laying of RCC half round cement pipe of appprox. Size (150/300mm dia X 2 mtr. length) inside the trench after laying of cable. Pipes shall be placed as per directives of site engineer.

2500

33

84100

... More
Painting two coats of synthetic enamel paint over one coat of Red Oxide primer after scrapping and cleaning of the surface wherever necessary with contractor own supply of primer and 56 paints over all outdoor gears including lifting barrier, axlecounter, ground frame, point machine, location boxes, signal post, unit, track circuits etc The work shall be done as per extant practice on C Rly & the instructions of Rly engineer at site. (Paints to be used shall conform to relevant IS spec.). This includes Lettering / Numbering Termination particulars, equipment names etc. legibly and neatly inside and outside surface of units, boxes etc.- for small stations.

1

21487

21487.45

... More
Painting two coats of synthetic enamel paint over one coat of Red Oxide primer after scrapping and cleaning of the surface wherever necessary with contractor own supply of primer and 57 paints over all outdoor gears including lifting barrier, axlecounter, ground frame, point machine, location boxes, signal post, unit, track circuits etc The work shall be done as per extant practice on C Rly & the instructions of Rly engineer at site. (Paints to be used shall conform to relevant IS spec.). This includes Lettering / Numbering Termination particulars, equipment names etc. legibly and neatly inside and outside surface of units, boxes etc.- for Big stations

1

53654

53654.78

... More
Painting two coats of enamel paint over one coat of Red Oxide primer on the following items after scrapping and cleaning of the surface wherever necessary. Primer and Paints both of any 58 reputed make are to be supplied by Contractor. The work shall be done as per instructions of rly engineer at site and extant practice on C Rly on location boxes, signal posts, TLJB. This includes lettering/Numbering of signals,TLJB & Block joints if any, apparatus Cases , gate booms , etc , Description writing , legibly and neatly inside location boxes , relay hut,gate lodge etc. - for LC Gate (Unit: Number = LOT/Gate)

1

6030

6030.58

... More
"Painting of two coats of synthetic enamel paint over one coat of primer on the following after scraping & cleaning surface wherever necessary with contractor' own supply of 59 paints.Wherever required contractor shall apply coating of epoxy paint also as per instructions of site- in-charge.Epoxy paint will be supplied by Railways. NOTE:- The paint and primer should be from M/s Asian paints Co. Ltd.,. The paints will be primer (IS 5660 of 1970) the Aluminium synthetic black enamel (IS 2932 of 1974) brilliant white and yellow Painting two coats of enamel paint over one coat of primer."

-

-

145737.6

... More
Lettering / Numbering of Signals, Point Machine, Track Lead Junction Boxes, Block Joints, Apparatus Cases etc. (each item to be taken as One Unit) This work will be carried out as per the standard practice being followed in Central Railway.

300

52

15681

... More
Lettering / Numbering Termination particulars, equipments names etc., legibly and neatly inside location boxes.

-

-

33861.5

... More
Releasing of Existing Panel, Power Equipments,relays and relay racks, CT racks, Batteries, Block Instts., Ground frame/s, Location Boxes, TLJBs, Signal Posts, Signal Units, Equipment inside the location boxes, Lifting Barrier , rodding runs,etc as applicable including the breaking of foundation etc. as per the instructions of Rly Engineer at site & their transportation to nominated depot. 63

1

37787

37787.66

... More
Laying of HDPE duct in trench and its protective work as per direction of site engineer.

2

5612

11225.98

... More
Blowing/Drawing of OFC cable in HDPE/DWC duct and protective work, as per direction of site engineer.

2

11926

23853.36

... More
Splicing (Jointing 2x24 F OFC) and testing of 24 fibre OF Cable and making the splice joint as per direction of site engineer with contractors own splicing machine and tools. Splice loss of each fibre should be less than or equal to 0.05db splice reflectence should be better than 60db.

2

5762

11524.16

... More
Supply of cable route marker as per RST/C/203A of FRP. (Inspection RITES)

200

311

62362

... More
Supply of Tool kit for Digital Axle Counter as per Annexure DAC toolkit . (Inspection RITES)

1

142621

142621.45

... More
Fabrication, supply and installation of wiring tree set for use in point machine (both for point operation and NKR/RKR) as per drawing approved by railways. (Inspection Consignee)

10

655

6550.9



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.