Central Railway Tender

Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.

Central Railway - CR Tender

Works
Telecommunication Services
Ireps
Opening Date3 Jan 2025
Closing Date27 Jan 2025
Tender Amount₹ 2,59,86,026.1 
Notes
Download

Costs

Summary

Signaling Work Related To Additional Loop Line Of At Moorsa Station Between Tadali- ghughus Section Of Nagpur Division.

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply of Transformer 230V/110V-130V Single phase 1 KVA as per spec. IRS S-72/88 (Amd.2) with latest amendments. (Inspection Agency- Consignee)

4

7019

28079.52

... More
Supply of Battery charger self regulating floor mounting type with 230 V AC single phase input and output 60 V DC, 10 A as per spec.IRS.S.86/2000 (Amd.4) with latest amendments. (Inspection Agency- RDSO)

2

42362

84724.68

... More
Supply of Battery charger self regulating floor mounting type with 230 V AC singlephase input and output 110 V DC, 20 A as per spec.IRS.S.86/2000 (Amd.4) with latest amendments. (Inspection Agency-RDSO)

2

75001

150002.92

... More
Supply of Battery charger self regulating floor mounting type with 230 V AC single phase input and output 24 V DC, 20 A as per spec.IRS.S.86/2000 (Amd.4) with latest amendments. (Inspection Agency- RDSO)

4

30236

120945.16

... More
Supply of Rubber Mat 5mm thick for use in signaling installation. (Inspection Agency- Consignee)

100

103

10355

... More
Supply of Automatic changeover for individual supply. Automatic changeover unit of 9 signal / Track / DC circuit supply of 32A, AC/DC consisting of 3TC44 contractors, LED Lamp, Push button, terminals, VSR, polarity switches. As per Rly. Drg.-SK-841/1-5 for IPS supply to manual discrete equipments with P/switch. (Inspection Agency- Consignee)

12

23487

281851.68

... More
Supply of QNA1 AC immunized relay, 8F-8B, 24 VDC along with plug, board, retaining clip and connectors conforming to BRS:931A, IRS:S60, IRS:S34 & IRS:S23 (Inspection Agency- RDSO)

10

3384

33844.4

... More
Supply of QSPA1 relay, 24 V DC Slow to pick up, 8F- 4B along with plug, board, retaining clip and connectors conforming to BRS:933A, IRS:S60, IRS:S34 & IRS:S23 (Inspection Agency- RDSO)

10

3878

38787

... More
Supply of QTA2 AC immunized track relay, 9 Ohm, 2F.1B, along with plug, board, retaining clip and connectors conforming to BRS:939A, 966 & Appendix F2, IRS:S34 & IRS:S23 (Inspection Agency- RDSO)

10

3391

33910.1

... More
Supply of QBCA1 AC immunized relay, 2FHD 4F-4B, 24VDC along with plug board, retaining clip and connectors conforming to BRS:943 POINT CONTACTOR RELAY. And IRS S46. & firms specification. (Inspection Agency- RDSO)

10

3786

37865.7

... More
Supply of QL1 LATCH relay, 11F-4B or 8F-6B along with plug board, retaining clip and connectors conforming to BRB:935A. (Inspection Agency- RDSO)

10

3786

37865.7

... More
Supply of Key Lock Relay working on 24V DC, AC immunized with different ward combinations (Three ward plates to be supplied with each relay). RDSO/SPN/219/2016 Version 1.0 d 1 (Inspection Agency- Consignee)

3

5218

15655.23

... More
Resin cored wire as per specification No.IS:1921-1975 with Alloying element percentage as 63% SN (Tin) nd / 37% pb (Lead) with percentage of various impurities not exceeding 16 the values Sb (Antimony 0.2% maximum, Cu (Copper) 0.1% maximum, As (Arsenic) 0.05% maximum, Fe (Iron) 0.02% maximum & other impurities mainly AI, Zn & Cd shall be limited. The flux shall be free from corrosive action as per clause 5.2 & flux percentage may be used as per requirement. (Inspection Agency- Consignee) 17

5

1100

5502.25

... More
Lacing thread rolls, black, wax coated (100 mtrs) (Inspection Agency- Consignee)

50

58

2906

... More
Design, fabrication and supply of fuse Auto changeover system for 32 No's external 18 non detorating type fuses or 'G' type fuses from 0.6A Amp to 4A Amp capacities used in signaling circuits. System shall have 8 cards with monitoring arrangement of 4 fuses in one card. As per RDSO spec. RDSO/SPN/209/2012 Ver.2.0 or latest amendment if any. (Inspection Agency- RDSO) (Unit 1 Number = No. of Module)

4

23509

94039.8

... More
Supply of Signal No.Plates. As per Drg No RST-11393/ SK-842 (Inspection Agency- Consignee)

20

458

9166.6

... More
Supply of Hand Cuff Locks / Godrej Navtal lock with Three common keys. (Inspection Agency- Consignee)

20

251

5028.8

... More
Supply of "2 aspect" Signal Unit in FRP body without lenses and transformers as per 21 RDSO Specification RDSO/SPN/194/2006/Rev.2.0 or latest complete and to suit LED signal Lamps and suitable for 140 mm dia post saves pigment finish on the back side of the and inside. white pigment finish inside the 2 aspect unit to avoid any extra paint cost. (Inspection Agency- RITES)

4

27181

108726.12

... More
Supply of "3 aspect" Signal Unit in FRP body without lenses and transformers as per RDSO Specification RDSO/SPN/194/2006/Rev.2.0 or latest complete and to suit LED signal Lamps and suitable for 140 mm dia post saves pigment finish on the back side of the and inside. white pigment finish inside the 4 aspect unit to avoid any extra paint cost. (Inspection Agency- RITES)

-

-

22

... More
Supply of Shunt Signal Position Light Type FRP complete as per RDSO Specification 23 RDSO/SPN/194/2006/Rev.2.0 or latest with Off set bracket 3-1/2" to be fitted on 140 mm post drawing No.SA23840(Adv) Alt-2 for dependent type complete with signal unit bracket, terminals etc without lenses, lamp, lamp holder, and to suit LED signal lamps. (Inspection Agency- RITES)

5

12255

61279.4

... More
Supply of 2 way junction Route Indicator in FRP body without lenses and transformers as per RDSO Specification RDSO/SPN/194/2006/Rev. 2.0 or latest complete and to suit LED signal Lamps. (Inspection Agency- RITES)

2

35518

71037.88

... More
Supply and Fixing of RE Protective Screens of expanded metal 12 SWG of size 1200 x 1500 mm on signals as per extent practice & as per instruction of Rly engineer at site DRG - No.SK- 844. (Inspection Agency- Consignee)

2

4592

9184.7

... More
Supply of ARA Terminal blocks with links made of PBT Specn No.IRS/75/2006 (Rev - 2) with latest amendments and RDSO Drg.No.SA-23741A Alt.4., SA-23745 Alt.5, SA-23746, SA-23748 Alt.4, & SA-23756 Alt.3. (Inspection Agency- RDSO)

2000

63

127580

... More
Supply of cartridge fuse block made of PBT as per RDSO Drg No SA-23748 Alt 4, SA- 23749 & Spec No.IRS S 75/2006 with latest amendment. Fuse block shall be suitable for found head type voltage fuses. (Inspection Agency- RDSO)

50

143

7157.5

... More
Supply of round head type non detoriating type low voltage cartridge fuse as per specn No. IRS/S/78/92 with latest amendments - 2A/4A/6A capacity (Inspection Agency- RDSO)

100

61

6161

... More
Supply of three pole plug and socket 5 Amp (as per IS Specification). (Inspection Agency- Consignee) 30

10

202

2028.2

... More
Supply of Lamp 110V / 24W, 2 pin for Loc. (Inspection Agency- Consignee)

100

18

1817

... More
Maintenance Free Earth as per RDSO/SPN/197/2008 or latest consisting of : 1) Copper 31 bond steel electrode 3 Mtr long 17mm dia with copper bonding thickness of min. 250micron & UL listed & marked-01 No. (2) Earth enhancement compound RDSO Approved in sealed bag of 10 kgs - 03 No. (3) Copper strip 150 x 25 x 6mm - 02 No (4) Copper Strip 300 x 25 x 6mm- 01 No (5) 35 Sqmm Copper Cable to connect earth electrode to MEEB - 15Mtr Approx. (Inspection Agency- RDSO)

60

15626

937561.2

... More
Supply of Microprocessor based universal earth resistance sensing unit 12 channel AC/DC. As per RDSO/SPN/256/2002 with latest amendments. (Inspection Agency- RDSO)

10

116413

1164138.6

... More
Supply of Track feed battery chargers, 110V AC input 2, 4 to 6 V DC Output to Specn. No.IRS.89/2013 Ver.1.0 with latest amendments. Charger shall be suitable for charging 80 AH battery. (Inspection Agency- Consignee)

10

1942

19427.8

... More
Supply of Channel Pins single groove, galvanized, 7 mm suitable for 4mm dia bonding wire as per spec No. IRS: S 17-75 Revision 3. (Inspection Agency- Consignee)

1000

1

1770

... More
Supply of PVC jacketed wire rope for track lead connections. PVC jacketed wire rope 35 should be of Galvanised steel wire rope 6mm dia (6x19 stranded wire with steel core of 6 mm dia) sheathed with PVC 2mm wall thickness, overall thickness being 10 mm. PVC sheath should be made of type 6 compound as per IS 5831 of 1984 Reaffirmed 2001 and steel wire rope as per IS: 2266:2019. Reclaimed for recycled material should not be used. (Inspection Agency- Consignee)

2000

45

91880

... More
Supply of 8 SWG GI wire (4mm dia) suitable for track circuit rail bonding. As per IRS Specification S:13@45>46@ (Inspection Agency- Consignee)

5000

76

381400

... More
Supply of RCC pipes half round of size 150mm dia outer and 100 mm dia internal 1 mtr long matching to IS No.458/2003 amendment-1 with Rev.4. (Inspection Agency- Consignee)

200

181

36220

... More
Supply of RCC pipes half round of size 300 mm dia outer and 250 mm dia internal 1 mtr long matching to IS No.458/2003 amendment-1 with Rev.4. (Inspection Agency- Consignee)

-

-

38

... More
Supply of modular terminal block of 2.5 sq. mm 2 IN 2 OUT type disconnect type 39 terminal along with as per RDSO SPN/189/2004 Rev 3.0. The current capacity of 16 Amps and more. The terminal should have marking at centre to view description from front. Material to be procured from RDSO approved firms only. (Inspection Agency- RDSO) 40

1500

102

154335

... More
Supply of DIN Channel for the terminals 1 Mtrs each (Inspection Agency- Consignee) 41

18

190

3427.38

... More
Supply of End plates for modular terminal block (Inspection Agency- RDSO) 42

36

20

739.8

... More
Supply of End Clamp for modular terminal block (Inspection Agency- RDSO) 43

36

14

531.36

... More
Supply of Marker Card as per customer spec (10x10) (Inspection Agency- Consignee)

18

73

1325.34

... More
Supply of Paints as per relevant IS specification preferably Asian / Apcolie/ Dulux make in different colour in one kg/2 kg pack

100

310

31018

... More
Supply of 4.5 kg CPO2 type fire extinguisher along with all accesarious, exinguisher testing certificate has to be supplied along with - Supply of ISI marked CarbondiOxide type (BC) fire 45 extinguisher of 4.5 Kg capacity confirming to IS 2878: 2004 from seamless cylinder, with IS marked control value, high pressure mtr., Long discharge hose and horn complete with initial gas charged with carrying handle and wall mounting braket etc. as required by site Engineer. (Inspection Agency- Consignee)

10

4012

40122.9

... More
Installation of Relay Rack Assembly including IDF pillars if any complete with wall 1 supports, scaffolding, ladders, runway for cables, Relay/Relay group base plates, fixing of Tag blocks etc. The work shall be done as per approved plan, extant practice on C.Railways & the instructions of Rly engineer at site.

1

1348

1348.32

... More
Charging of 2V Lead Acid Batteries with contractors own battery grade sulphuric acid 2 and distilled water with minimum two charge - discharge cycles, installation of charged batteries in groups & their connection & wiring. The work shall be done as per extant practice of C.Rly & instruction of Engineer-in-charge. Detailed measurements of initial charging shall be recorded jointly by contractor & Rly's site-in-charge.(Unit 1 Number = Per 100 VAH)

48

66

3199.2

... More
Installation of LT Power panel/power distribution panel/Auto Changeover Panel, power 3 supply equipments such as Rectifiers Transformers, Battery chargers etc., mounting of program switches on Bakelite sheet of size 300 mm x 300 mm x 8 fitted to MS angle (size 25mm x 25mm x 5mm) brackets, wiring as per requirements. Necessary wires to be supplied by Rlys, lugs & glands to be supplied by contractor. (Unit 1 Number = 1 LOT)

1

21142

21142.1

... More
Wiring, fixing & commissioning of modules of fuse 0.6 to 4 Amp rating alarm system having change over arrangement and potential free contact wiring at Data logger IDF. Etc as per instructions of Railway Engineer. (Module of 32 nos fuses) (Unit 1 Number = No. of Module)

4

568

2273.2

... More
Lettering & Numbering of detail and description writing of particulars of terminations & 5 equipments on relay rack, relays, cable termination rack, battery & power equipment, IPS, operating panel, axle counter etc constituting entire system with contractor's own paint and writing material ("Asian/Dulux" make enamel paints to be used). The work shall be done as per extant practice on C.Rly & instruction of Rly engineer at site. (Unit 1 Number = Per Rack)

2

323

647.44

... More
Preparation of cable route plan, cable coreage plan, location particulars, cable 6 termination rack particulars, cable meggering report, earth resistance particulars, Traction bonding diagram, 1/2 wire count sheet and any other drawing in Autocad in A3/A4 size. The contractor shall initially supply 3 sets of circuits complete for approval of Railways. Railways will return one set to the contractor duly approved with alteration/corrections if any. The contractor shall incorporate Railways alterations/corrections in the tracings without any deviation and submit all tracings complete in all respects to the Railways. This includes submission of final cable route plan as per laid cable duly measured at every 30m clearly indicating distance of laid cable from fixed point of reference & indicating all track crossings and tail cables. This also include designing of cable coreage plan based upon I.P. in consultation with engineer-in-charge. For small/medium yards (<=100 routes) (Unit 1 Number = Lot)

1

21128

21128.78

... More
Excavation and Casting of main signal foundation as per Drg No SK 801 with 7 contractor's own materials including cement and anchor bolts of standard size. The required scaffolding Ferma etc for casting of foundation will have to be brought by the contractor at his own cost.

5

8038

40190.3

... More
Excavation and Casting of Shunt signal foundation as per Drg No SK 802 with 8 contractor's own materials including cement and anchor bolts of standard size. The required scaffolding Ferma etc for casting of foundation will have to be brought by the contractor at his own cost.

3

2117

6353.37

... More
Erection of CLS post with surface base and signal unit on top or on OFF set Bracket, 9 fixing of front and back staging, ladder and guards, signal name plates/boards if any with contractors own brackets and fixing materials. This also includes erection of auxiliary signals like calling on, shunt signal if any. The work shall be done as per instructions of Rly engineer at site.

5

3066

15331.5

... More
Erection of shunt signal with surface base, post, signal unit and fixing of No. plates. The work shall be done as per instructions of Rly engineer at site. 11

3

384

1154.58

... More
Fixing of Jn. Route Indication 1-way/2-way/3-way on the top of the signal post.

2

670

1341.88

... More
Fixing of stop Board, Block section limit Board, goods warning board with contractors own material. The work shall be done as per instruction of Rly engineer at site.

1

442

442.29

... More
Termination of tail cable on Main signal units and wiring with contractor own material etc. The work shall be done as per instruction of Rly engineer at site.

5

963

4815.6

... More
Termination of tail cable on Shunt signal units and wiring with contractor own material etc. The work shall be done as per instruction of Rly engineer at site.

5

312

1564.85

... More
Installation on ON/OFF aspect LED's in signal including termination of tail cable on signal, wiring fixing of LED units and testing. The work shall be done as per instruction of Railway engineer at site.

20

479

9587.4

... More
Fabrication and fixing of phenolic laminated/Fiber glass sheet in location box by 16 providing all fixtures as per Railway Drawing including fixing of PVC coated/with PVC pipe covered string rods at the back side for cable support with contractor's own materials. The work shall be done as per Drg and arrangement similar to SK 783- 1& 2. with latest alterations & as per instructions of Rly engineer at site.

-

-

28500.95

... More
Fixing of cutting in relay bases & wiring of relays with Contractors own material obtained from approved sources in location box as per the instructions of Engineer in charge.

10

497

4974.7

... More
Fixing of ARA Terminals and fuse blocks on phenolic laminated sheets and fixing by stainless steel/brass nuts & bolts. This includes provision of two additional holes on the board on either side for cable conductor entry. (Unit 1 Number = Per Conductor)

2050

12

25297

... More
Termination of cable cores on ARA terminal/fuse blocks in the apparatus cases/ cable 19 termination rack. This includes all associated works of pulling out the cable from underground. The work shall be done as per location plans and instructions of Rly engineer at site. (Unit 1 Number = Per Conductor)

4100

9

38130

... More
Excavation and Casting of Apparatus case foundation with contractors Anchor bolts, cement, ballast and other materials. The required scaffolding ferma etc for Casting of foundation will have to be brought by the contractor at his own cost. 21

-

-

129443.95

... More
Erection of Apparatus cases. This includes filling of location foundations and plastering.

-

-

13347.2

... More
Installation of Eqpt. (Relays, resistance, chargers batteries etc. as applicable) & wiring of the same in apparatus cases as per location diagrams & circuit diagrams, as per Instruction of site incharge and practice.

-

-

17628.8

... More
Installation of earth electrode assembly as perDrg.No.RE/S&T/SIG/Tender/SK726/85 including earth wire connected through GI wire 8 SWG supported on M.S. flat of size 6mm x 40 mm to earth electrode as per drg. No.CR/S&T/SK-815 for sigg. Equipment such as lever frames, apparatus 23 case, signals, relay racks, block instruments, and etc. as per RE manual. The earth value should be less than 10 Ohms including the lead wire. The value should be measured in presence of Rly. supervisor. It should be documented and painted on earth enclosure made of concrete.( only earth electrode will be supplied by Railway). All other material required for provision of earthing will be brought by the contractor.

10

2221

22210.8

... More
Installation of unit earth as per RDSO/SPN/197/ver. I or latest, to construct earthing of

60

4647

278866.8

... More
Installation, wiring, testing and commissioning of Microprocessor based universal earth leakage detector unit 12 channel AC/DC.

10

5924

59243.8

... More
Erection, Fitting and Rail connection of Track Lead junction Box on two supports 26 (M.S.angle) with contractor's fixing material and PVC jacketed wire for track lead connection including angles of size 40x40x5mm 1200mm length. This will include drilling of holes for track led/side connections of rail. The work shall be carried out as per Drg. No.SK-845 or / & instructions of Rly engineer at site.

15

1146

17202

... More
Provision of bounding with contractor's PVC jacketed wire rope for Track Lead connections. PVC jacketed wire rope should be of Galvanized steel wire rope 6 mm dia (6x19 stranded wire with steel core of 6mm dia) sheathed with PVC 2mm wall thickness, overall thickness being 10 27 mm. PVC sheath should be made of type 6 compound as per IS 5831 of 1984 Reaffirmed 2001 and steel wire rope as Per IS:2266:2019. Reclaimed or recycled material should not be used. This will include drilling of 7.1mm dia holes in rails (4 Nos) and provision of two jumpers for each bond, clipping of bonds etc. with contractors own materials and tools as per instruction of Rly engineer at site.

100

169

16965

... More
Provision of bounding with GI wire 4mm dia (8 SWG) for track jumper & fish plate joints bonds. This will include drilling of 7.1mm dia holes in rails (4 Nos) and provision of two jumpers for each bond, clipping of bonds etc. with contractors own tools as per instruction of Rly engineer at site.

200

140

28198

... More
Installation of Axle counter (Digital)/Central Evaluator, wiring from CT rack to central evaluator, installation and wiring of indoor & outdoor reset box and wiring the power supply including 29 supply of 2 core shielded cable of required size copper conductor as per IRS S 76/89 or IS694/1977 as applicable with other accessories. NOTE: Installation/programming/configuration/commissioning of Axle counter equipment to be carried out in accordance with latest guidelines issued by Railway/RDSO preferably by Authorized representative of OEM.

6

24019

144116.46

... More
Installation of EJB and Track devices of Digital Axle counter including digging of trench, drilling of holes, if required on rail, lying of Doubled walled antirodent corrugated pipe, Medium class 30 from track device to location box and making its terminations. (DWC pipe made up of High density polyethlene of 60mm outer dia of suitable length and all other accessories as per site requirement to be supplied by firm.) NOTE: Installation/programming/configuration/commissioning of Axle counter equipment to be carried out in accordance with latest guidelines issued by Railway/RDSO preferably by Authorized representative of OEM.

30

13820

414625.8

... More
Installation of complete assembly of deflectors on either side of Track Device/Double Rail contract Unit including drilling of required sizes holes on rails for fixing these. (Unit 1 Number = Per DP)

-

-

31

... More
Supply, fixing & Wiring of mismatch panel depicting Indication panel/VDU layout with 32 contractors own material like LEDs for each track section, flexible wire, connecting terminals, buzzer etc. The work shall be done as per extant practice on C.Rly & the instruction of Rly engineer at site. (Unit 1 Number = Per Station)

1

50121

50121.31

... More
Refixing of electrical point machine, ground connection during phase working (Non 33 interlocked working) after removing the existing fitting if any, adjustment if necessary, cable termination, wiring, testing and commissioning of electrically operated point, fixing and connecting point indicator on derail switch if necessary. The work shall be done as per extant practice on C.Rly & the instruction of Rly engineer at site. (Unit 1 Number = Per Turnout)

4

3637

14551.56

... More
Fixing of point machine on newly laid turnout on Wooden/MBC sleepers, fixing of ground connections, adjustment and testing with crank handle operations, Removal of ground 34 connection & point machines duly numbered. The will include fixing of bend pipes with welded frame for cable entry to machine. This will also includes necessary adjustment and smithy work, drilling of holes to tounge rails, fitting of insulation for tounge attachment, gauge plate & stretcher bars, cable termination & wiring if required. The work shall be done as per extant practice on C.Rly & the instruction of Rly engineer at site. (Unit 1 Number = Per Turnout)

6

2819

16915.92

... More
Excavation of cable trench as per cable route plan, 1.0 mt. deep and 300mm wide along side thew track in normal soil/strata, conforming to distances as per cable route plan and refilling after cable laying. This work includes covering of cable laid to trench by loose soil for a layer 35 of 50mm thickness after clearing of route, bushes etc. It shall be ensured that top of the cables laid is at a depth of 0.8 m or more. If it is less, then the width and depth shall be suitably increased and accordingly proportionate payment shall be made. In case depth of trench is not achievable due to site conditions, proportionate payment will be made as per procedure. The work shall be done as per extant practice on C.Rly & the instruction of Railway engineer at site. Drg No SK 805

600

307

184494

... More
Excavation of cable trench as per cable route plan, 1.0 mt. deep and 300mm wide along side the track in hard soil, conforming to distances as per cable route plan and refilling after cable laying. This work includes covering of cable laid to trench by loose soil for a layer of 50mm 36 thickness after clearing of route, bushes etc. It shall be ensured that top of the cables laid is at a depth of 0.8 m or more. If it is less, then the width and depth shall be suitably increased and accordingly proportionate payment shall be made. In case depth of trench is not achievable due to site conditions, proportionate payment will be made as per procedure. The work shall be done as per extant practice on C.Rly & the instruction of Railway engineer at site. Drg No SK 805.

60

512

30748.8

... More
Cutting of all types of Roads/platforms (except concrete type) for trenching and 37 excavation to depth of 300mmx300mm wide approx. and refilling after laying of RCC/GI/DWC pipe & to restore them to original condition. The work shall be done as per extant practice on C.Rly & the instruction of Railway engineer at site. Drg No SK 807

9

2562

23061.69

... More
Fixing of GI pipes for crossing the culverts, bridges etc. and concreting of ends with brick masonry at both ends as per the instruction of Rly engineer at site.

24

61

1475.28

... More
Digging of trench 1.0 M deep from rail flange/road level (for LC) and, 0.3 Mtr to 0.6 39 Mtrs wide and back filling after placing of DWC/RCC/GI pipe. (Placing of DWC/RCC/GI pipe covered separately). The ballast disturbed be screened and dressed as required by Engineer-in-charge or his representatives and road tarred immediately. Drg No SK 806

40

512

20499.2

... More
Laying of DWC/RCC pipes along with collars / RCC Half round pipes in trenches at places of track and road crossings, platform cutting etc. 41

50

45

2272.5

... More
Laying of signaling/Power/Telecom cable of various cores/sizes in trenches.

40

4566

182645.6

... More
Jointing o 4 / 6 quad cable with Heat shrinkable straight through jointing kit for 4/6 quad cable.

2

3129

6259.06

... More
Wherever depth of 0.5 m cable trench is not feasible, cable shall be protected as under: Preparation of cement mixture 1:3:6 with contractor's own materials and spreading cement 43 concrete mixture layer of 100 mm thick over the already laid cables in the excavated trench.

10

4682

46822.3

... More
Fixing of modular terminal/fuse blocks along with all accessories with provision of 44 fixing holes on hylam sheets/side angles of Loc Box and fixing by galvanized nuts & bolts. This includes fixing on DIN channel along with PVC Comb type 'C' channel (size 2 inch x 2 inch) for cable termination of modular terminal. The PVC channel with cover to be supplied by firm as required. The work shall be done as per the instruction of Rly engineer at site.

1500

16

25110

... More
Termination of cable cores on ARA terminal/Disconnecting link/fuse blocks, in the 45 apparatus Cases/ cable termination rack. This includes all associated works of pulling out the cable from underground. The work shall be done as per location plans and instructions of Rly engineer at site.

3000

6

18720

... More
Laying of GI pipes in on bridges/culverts/concrete drain/ mountain ridges etc. with 46 suitable GI bend shall be provided where there is turning of pipe as per instructions of the site engineer. GI Clamps at every 2 m as shown in the drawing to be fixed. suitable holes to be made in the pipe before laying as per instructions of the site engineer. 100 mm dia. Drg No SK 808

12

126

1513.32

... More
Laying of GI pipes inside the excavated trench in rocky area/less depth area as per 47 instructions of the site engineer. GI Clamps t every 2 m as shown in the drawing to be fixed. Suitable GI Bend/Coupling and holes to be made in the pipe before laying as per instructions of the site engineer.

12

64

771.84

... More
Releasing of cables from old location boxes and taking it into new location boxes. This 48 includes excavating the earth to release the cables. From old location box for taking it into new location. This also includes releasing the old location box and bringing it to nearest station/central cabin. Location (old) will be released only after ensuring all working cables have been shifted in New location. (Unit 1 Number = Per Location)

5

1824

9120.55

... More
REMOVAL OF PSC/Wooden SLEEPERS coming in the way of/route of cable trenching, signal/Location foundation/Track Crossing etc. These obstruction will be removed by contractor for ensuring proper execution of related works.

10

123

1237.6

... More
REMOVAL OF Redundant/Old Rails coming in the way of/route of cable trenching, signal/Location foundation/Track Crossing etc. These obstruction will be removed by contractor for ensuring proper execution of related works.

10

124

1241.6

... More
FIXING OF "C" Channel Clamps on Girders. Along with proper coupling of GI/DWC pipes. 51 The work will be executed as per instruction of site in-charge and site in-charge may take decision as per site condition. All the fixtures, nut bolts, tolls required to fix the channel will be provided by Contractor. proper safety equipment like Helmet, Reteroreflective jacket and whistle, flag is to be made available during execution of work.

4

310

1240.24

... More
Making an entrance for new cable in old existing location, Casting concreting and curing of foundation and restoring it to old position by perfect masonry/concreting work. Contractor will ensure that cable entered in Location Box is properly protected.

5

405

2028.8

... More
Horizontal boring of cable duct of minimum 2.0 Mtr depth along with laying of 120mm HDPE pipe for track crossing with minimum depth reckoned from bottom of the rail/Road crossing with 53 minimum depth reckoned from ground level. The work shall be done as per extant practice & instructions of site engineer. Preparation of site for Horizontal Boring shall be carried out in presence of Representative. HDPE will be supplied by Railway. Note:- Contractor shall provide all material required for boring and adequate nos. of labours for proper laying of cables into the bore. Cable shall be laid cautiously so that it should not get damage due to rough handling & pressure on cable.

300

2293

688020

... More
Termination of Tail cable inside the point machine through bend pipe this includes preparatory work of pulling the cables, and peeling out the insulation, dressing and lacing after 54 termination etc., pulling of tail cable as per circuit requirement inside point machine through bend pipe, termination of cables on terminal blocks as per instruction of site supervisor the cable shall be entered in such a way that, armouring shall protect the cable near sharp edge of entry point and armouring shall be clamped between pipe fixing bracket and boy of point machine.

8

308

2467.36

... More
Patching work in old location box consisting 1) Digging of pit, cleaning of earth from all 55 sides, breaking of seal of location boxes removal of sand from location, marking of new cable holes. 2) insertion cable from ground 3) making place for cable termination in old location, shifting ARA, fuse etc after removal and termination including fixing of ARA. 4) Termination of cable in old location. 5) Filling of sand and plastering to all sides upto 50 mm below ground level.

2

5517

11034.32

... More
Shifting of existing full location boxes coming in the alignment of doubling. The work includes losing & removal of soil around loction boxes by excavating soil around foundation, making of pit for shifting of location box horizontally opposite to railway track up to 0.5 to 1.0 mtr. This 56 includes loosing of existing cable coils without any damage. The excavated soil shall be back filled after shifting of Location Boxes. Location box along with its foundation shall be shifted by push method with the help of jacks or by crane by contractors own expenditure under instructions of engineer in-charge at site. Any minor repairs in foundation due to patching shall also be carried out by contractor as per instruction of Engineer incharge. The work may affect train working hence the work shall be done as per margin only or during traffic block only.

2

4786

9572

... More
Shifting of existing Half location boxes coming in the alignment of doubling. The work includes losing & removal of soil around loction boxes by excavating soil around foundation, making of pit for shifting of location box horizontally opposite to railway track up to 0.5 to 1.0 mtr. This 57 includes loosing of existing cable coils without any damage. The excavated soil shall be back filled after shifting of Location Boxes. Location box along with its foundation shall be shifted by push method with the help of jacks or by crane by contractors own expenditure under instructions of engineer in-charge at site. Any minor repairs in foundation due to patching shall also be carried out by contractor as per instruction of Engineer incharge. The work may affect train working hence the work shall be done as per margin only or during traffic block only.

2

3854

7709.26

... More
Laying of RCC half round cement pipe of approximate size (150/300 mm dia X 2 Meter length) inside the trench after laying of cable. Pipes shall be placed as per directives of engineer.

1200

32

38424

... More
Painting two coats of synthetic enamel paint over one coat of primeron the following after scrapping and cleaning of the surface wherever necessary with contractor own supply of paints. 59 Wherever required contractor shall apply coating of epoxy paint also as per insructions of site-in- charge. Epoxy will be supplied by Railways. NOTE:- The paint and primer should be from M/s Asian paints Co. Ltd.,. The paints will be primer (IS 5660 of 1970) the Aluminium synthetic block enamel (IS 2932 of 1974) brilliant white and yellow Painting two coats of enamel paint over one coat of primer.

-

-

12321.4

... More
Lettering / Numbering of Signals, Point Machine, Track Lead junction Boxes, Block joints, Apparatus Cases etc.(each item to be taken as One Unit) This work will be carried out as per the standard practice being followed in Central Railway.

55

49

2736.8

... More
Lettering / Numbering Termination particulars, equipments names etc., legibly and neatly inside location boxes.

-

-

2974.25

... More
Dismantling/Releasing of the existing outdoor signaling items such as CLS unit with posts alongwith base, lever frames (5 levers set), battery box with equipments, location box with 62 equipments, block instruments, point machines, mechanical point, AFTC/DAC, Relay rack, CT Rack alongwith Relay rack. IDF with all accessories. All these unit will be counted as one no. along with their accessories. This includes the cost of transportation of released material from site to Railway scrap Depot.(Unit 1 Number = per signl/per point/Loc.Box/Relay Rack)

6

1294

7764.48

... More
Transportation of signaling material/equipments including loading and unloading in 63 10MT vehicle, anywhere to anywhere, and stacking at destination as per instructions of SSE in-charge as per inventory. For carrying heavy materials like cable drums, DG set, Electrical lifting barrier pedstal, IPS, Batteries, Point machine etc. (Unit 1 Number = Per Ton/Per Km

2000

47

94720

... More
Supply and fixing of cable route marker of concrete Make as per Drawing Attached. (Inspection Agency- Consignee)

20

303

6067.6

... More
Providing Road breaker/Concrete Breaker with compressor and jack hammer for railway work such as cutting and dismantling of road concrete/ Bricks pucca structure (RCC/Steel section) including contractor's fuel, driver and all other charges completed as directed by Engg in charge. (Unit 1 Number = Per Hour)

-

-

2

... More
Hiring of Road Crane of 25MT capacity including necessary fuel, oil and operator etc. 3 complete as directed by engineer in-charge. The contractor shall be responsible for arranging al types of permits required for movement of the Crane. Payment shall be made for actual working hours at site. (Unit 1 Number = Hour)

4

1051

4207.92

... More
Supply of True RMS Industrial Logging Multimeter with trend capture as per specification attached Make: Fluke 289 or similar. (Inspection Agency- Consignee)

1

61089

61089.36

... More
Supply and installation of Modular Power Supply Arrangement for VDU (42 Inch - 85 Inch) and Industrial PC (Embedded PC) with Input and Output Redundancy Arrangement and Hot gable Modules. Consisting of: 1. Input O-Ring Diode Module with Potential Free-1 No contacts (PFC) for 5 two 110VDC Sources from IPS and Single 110VDC bus. 2. Isolated Inverters (Master/Slave) -2 Nos. Input: 110VDC, Output: 120VAC/220VAC 500VA 3. Isolated DC-DC Converters-2 Nos. Input:110VDC, Output:24VDC/10A. 4. 3U SS Rack with back Panel Mother Board/ Front Panel Power Connectors Inverter Auto Change Over Switch and all required over Switch and all required protection circuits as per RDSO specifications. (Inspection Agency- Consignee)

2

183941

367883.88

... More
Supply, installation , wiring and commissioning of bumpless power supply auto 6 changeover device complete along with accessories using contractor's own wiring and fixing materials as per following configurations: 1. Power supply - AC/DC 2. Voltage 24 V- 150V 3. Current upto 45A. Note: It should be compatible for MSDAC. (Inspection Agency- Consignee) 7

4

47164

188658.4

... More
Upgradation of Data logger

-

-

45329.48

... More
Preparation of station Working Rules, CRS minor sanction papers as practice in 8 Railways for Yards/LC Gate/IBH based on approved SIP &RCC .The firm has to submit one set for corrections &approval and after making desired corrections as advised by Rly. The firm will submit one set for signing & then 05 set xerox copies with Spiral Binding. (Unit 1 Number = Per Station)

1

8613

8613.59

... More
Supply of 120mm HDPE pipe for laying in Horizontal Boring. (Inspection Agency- Consignee)

500

716

358455

... More
Supply of Axle Counter Cable Conductor's Earth Resistance sensing unit, Microcontroller based for 12 nos. conductors with metering facility for one conductor at a time. (Inspection Agency- Consignee)

4

48377

193510.48

... More
Installation of Axle Counter Cable Conductor's Earth Resistance sensing unit, Microcontroller based for 12 nos. conductors without cable (Cable by railway)

4

6919

27678.76

... More
DC-DC converter modules of IPS of various supplies/make.(As per site requirement.) (Inspection Agency- RDSO)

34

16344

555713

... More
Supply of Cabinet with wiring arrangement for DC-DC converter, 08 Nos. suitable for Station IPS. (Inspection Agency- Consignee)

5

59722

298610

... More
Supply of Electronic Interlocking Parts for modification in existing Electronic Interlocking at MOORSA station. EI Make: Westrace Siemens.

-

-

3139600

... More
Supply of Digital Axle Counter Multi Section Type complete system including the central evaluator and final track section clearance relay for each section, Reset box, LV Boxes Track side electronic unit with detection point complete assembly including mushroom with protection cover & fixing arrangement for each detection point, clamps deflector for either side of each detection points, monitoring console etc. with all other accessaries fully wired and fully equiped for 5 DP and 4 Track Section as per RDSO Specification No. RDSO/SPN/176/2013 (VER3) or latest. The equipment must also include the following: a) system must have remote monitoring and remote diagnostic feature. b.)Diagnostic PC (Desktop)-1no./SET (As per attached Annexure-D) d.) Surge Protection Devices, c) Coil Length 5/10/15 meters each as per site requirement. (Inspection Agency- RDSO)

6

1689684

10138104.24



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.