Bridge And Roof Company India Limited Tender

... More
Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.

Bridge And Roof Company India Limited Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date24 Apr 2025
Closing Soon28 May 2025
Tender Amount₹ 8,58,04,772 
Notes
Download

AI Insights

Class Of Bidder
... View More
The class eligibility requirement to bid or participate in this tender is 'Class-I local supplier' or 'Class-II local supplier'.
Technical Capacity
... View More
The required prior work experience for the bidder includes: - RCM/SITE-IN-CHARGE: 5 years (degree) or 8 years (diploma) of experience in construction - LEAD DISCIPLINE ENGINEERS (ELECTRICAL): 3 years (degree) or 5 years (diploma) of experience in construction - LEAD PLANNING: 3 years (degree) or 5 years (diploma) of experience in planning and scheduling - ENGINEERS (ELECTRICAL): 2 years (degree) or 4 years (diploma) of experience in construction The bidder should have successfully executed similar works of a certain value during the last 7 years. The experience criteria are as follows: - 03 similar completed works each costing not less than ₹ 3.73 Crore - 02 similar completed works each costing not less than ₹ 4.66 Crore - 01 similar completed work costing not less than ₹ 7.46 Crore Substantial completion is based on 80% (value-wise) or more works completed under the contract.

Costs

Summary

Electrical And Instrumentation And It Service Work In Connection With Building 3 - Admin And Misc.buildings For Gail Usar Pdh-pp Project, Maharashtra

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply of 415V, 125A, TPN, indoor draw out type, 25kA (min) for 1 Sec. Al. Bus-barswitch board, double front, free standing floor mounted, bottom cable entry, metalenclosed switchboards suitable for operation at indoor site conditions with followingfeeders complete with meters, alarms, controls, protections etc. as per tenderSpecification 6-51-0018, job specification, hard-ware datasheets, componentdatasheet, other codes and standards attached or referred, including supply of allcommissioning spares, special tools and tackles & documentation, includingtransport, all labor and materials, as per approved drawings, specifications of thistender and directions of Engineer-in- Charge, complete in all respects.

-

-

-

... More
Height 15 u Width 19 Inch

4

18946

75787.2

... More
Type LED ADMIN2 Fixtures.

5

1553

7769.7

... More
Cables with OD above 30 mm but upto 40 mm

500

36

18000

... More
Supply of following indoor drawout type MV switchboard as per EIL specification No. 6 -51-0018, including all labour and materials, as per approved drawings, specificationsof this tender and directions of Engineer-in-Charge.

-

-

-

... More
Supply, installation, connection, testing and commissioning of emergency lighting unit (min. 5W, 100 lumens output) fed by a self- contained battery rated for 2 hours andcharger operating on 240 V AC supply, including all labour and materials, as perapproved drawings, specifications of this tender and directions of Engineer-inCharge.

12

3499

41990.4

... More
Cables with OD upto 20 mm.

50

174

8730

... More
3 Nos. 16/6 A, 6 Pin sockets with 1 Nos. 15A, switch (Flush Mounted Switch + Socket)

500

2274

1137150

... More
5 A, plate type flush/surface mounted switches.

1750

213

374062.5

... More
3 Nos x 4 sq. mm

500

132

66150

... More
24-port CAT-6A Jack Panel (fully loaded with 24 Nos. I/Os)

2

10687

21375

... More
FIRE PROOFING OF CABLES

-

-

-

... More
HAZARDOUS AREA LIGHTING FIXTURES AND ACCESSORIES

-

-

-

... More
Supply of nickel-plated, flame proof IIC double compression type brass cable glands, suitable for out door terminations of armoured PVC cables of following overalldiameter (excluding termination and connection of cables), including all labour and materials, as per approved drawings, specifications of this tender and directions ofEngineer-in-Charge.

-

-

-

... More
GI earth plate as per std. 7-51-0103

60

769

46170

... More
2 Pair x 1.5 sq. mm

100

94

9405

... More
FANS AND EXHAUST FANS

-

-

-

... More
Cables with OD above 20 mm but upto 30 mm.

50

253

12658.5

... More
5 Pair x 0.9 mm dia

500

136

68400

... More
3 C x 2.5 sq. mm

4500

25

115425

... More
Supply of following items as per applicable Indian standards/CEA Guidelines.

-

-

-

... More
Supply and installation of Poles for post top lantern as per std. 7-51-0210 with marshalling box, necessary wires/cable running from marshalling box to the lightingfixtures, cable termination and connection, fixing of cable glands and lugs, , includingall civil works, excavation, foundation, disposal of surplus earth, providing shoring,strutting and dewatering if required and supply of cement, steel, GI pipes, base plates,paint and all sundry materials as required, painting, including all labour and materials,as per approved drawings, specifications of this tender and directions of Engineer-inCharge.

-

-

-

... More
415 V, 125A MCCB incomer as per datasheet B378-999-16-50-DS-1814 along withMechanical Interlock

2

103500

207000

... More
50 x 6 mm

100

270

27072

... More
Supply and laying of (surface type) approved make of black enamelled steel conduit of following diameter and associated fittings from lighting/power panel, telephone, firealarm/plant communication points etc., including supply of G.I. sheet steel junctionboxes with acrylic cover, pull wire, including all labour and materials, as per approveddrawings, specifications of this tender and directions of Engineer-in-Charge.

-

-

-

... More
Type LED ADMIN18 Fixtures.

15

1379

20690.1

... More
Installation, testing and commissioning of IP-55 and IK-10 EV charging station ratedfor 230V, 32A, 7.4kW along with installation on wall/ channel/ column, cabletermination, configuration for access the station including all labor and materialscomplete as per approved drawings, job & standard specification attached with thistender, latest IS and IEC requirements and directions of the engineer-in- charge

3

9832

29497.5

... More
Supply and Laying of PVC channels of size OD 25 mm as per the specifications of this tender and directions of the Engineer-in-Charge.

10000

122

1228500

... More
SUPPLY OF MV CABLES

-

-

-

... More
Floor-standing Network Rack

-

-

-

... More
Horizontal bends for 450 mm wide tray with 1000 mm bending radius.

5

2360

11801.7

... More
Supply and Laying of PVC conduits pipe

-

-

-

... More
I/T/C of UPS System

-

-

-

... More
5/8" dia (16 mm) flexible rope

200

198

39744

... More
Supply Installation, Testing, Training & Commissioning of the following Equipment

-

-

-

... More
Supplying, laying, termination, testing and commissioning of 6 Core 1.5 SQ. MM,unarmoured Armoured, XLPE insulated, tinned copper conductor FRLS cable -Unscreened for Command/ Status/ Sensor

1500

249

374775

... More
Vertical outside bends for 450 mm wide tray with 1000 mm bending radius

5

2284

11421

... More
Type LED RSD-10 Fixtures.

100

1746

174600

... More
Height 42 u Width 19 Inch

4

54549

218196

... More
Circuit wiring with 660 V grade (sizes given below) PVC insulated copper conductorwires in already installed metsec channel including the supply of wires, termination,connection and harnessing of wires etc., including all labour and materials, as perapproved drawings, specifications of this tender and directions of Engineer-in-Charge.

-

-

-

... More
Supply, installation, testing and commissioning of Maintenance free earth pit as per sketch B378SKand job Specification and all necessary materialsincluding excavation of earth pit, filling with earth enhancing compound, back filling,providing necessary brickwork, connections, including all labour and materials, as perapproved drawings, specifications of this tender and directions of EngineerinCharge

100

30555

3055500

... More
25 mm diameter.

1500

58

87885

... More
Supply and laying MS conduit

2500

161

403750

... More
Design, Engineering and Supply of free standing, floor mounted, fixed type Uninterruptable Power Supply (UPS) System suitable for operation at indoor siteconditions along with battery banks (Ni-Cd Battery) and integrated system comprisingstatic rectifiers, battery charger, cell booster suitable for battery AH, accessories forbattery set, IGBTs, static inverters, static switches, manual by pass switch, IsolationTransformer, voltage stabilizer in bypass, isolating and protection devices and allother equipment/ accessories as required for completeness of the system whetherspecifically mentioned herein or not, but necessary for completeness and satisfactoryperformance of the system along with necessary control, metering and protectionequipment conforming to EIL specification 6-51-0017, 6-51-0047 & IS/IEC, etc.Supply of interconnecting cables between all equipments of UPS system (Between UPS,ACDB, Battery, battery charger and all other equipment supplied as a part of this UPS),commissioning spares, special tools & tackles, all labour and materials as perapproved drawings, specifications, job specification, datasheet, instruction to vendoretc. of this tender and directions of Engineer-in-Charge.

-

-

-

... More
Supply, installation, connection, testing and commissioning of following plug - in typesockets for Telephones extensions including supply of sheet boxes with coversconnection of socket and plug, including all labour and materials, as per approveddrawings, specifications of this tender and directions of Engineer-in-Charge

-

-

-

... More
Supply, installation, connection, testing and commissioning of Weather proof IP-55 safe area lighting/power panels along with GI canopy, surface/flush mounting type,wall mounting type in dust tight (with hinged cover) sheet steel enclosure having 4pole incomer and double pole MCB (9 kA type) for outgoing circuit control withcomplete wiring, including cable termination, connection and fixing of cable glands,including all labour and materials, as per approved drawings, specifications of thistender and directions of Engineer-in-Charge.

-

-

-

... More
Supplying, laying, termination, testing and commissioning of signal cables. (2 core 1.5mm2), Armoured, XLPE insulated, tinned copper conductor FRLS cable-screened forSensor/Integration/controller to controller communication

4500

116

525825

... More
Type LED 2 Fixtures.

1000

5534

5534820

... More
Cables with OD above 40 mm but upto 50 mm.

10

436

4365

... More
Supply and installation of push button station supports complete with base plate, foundations bolts, grouting and painting(as per Table-10 of specification 6-79-0020suitable for highly corrosive environment) etc., including all labour and materials, asper approved drawings and directions of Engineer-in-Charge.

-

-

-

... More
2 Winding Dry type transformers. .415 kV / .415 kV 50 kV·A

2

213750

427500

... More
200X40X1.6/3MM

1400

1455

2037420

... More
150 mm NB.

18

3175

57153.6

... More
MISCELLANEOUS CONTROL GEAR

-

-

-

... More
SAFETY EQUIPMENT

-

-

-

... More
CAT-6A I/O, Faceplates, Gang-box

805

1111

894757.5

... More
Hardness Analyzer

2

676561

1353123

... More
For highest systen voltage of 1.2kV

50

1555

77760

... More
Supply and installation of the following, including the supply of necessary clamps, bolts, rawl plugs etc., breaking and making good of walls, if required, mounting,including all labour and materials, complete and as per applicable standards and CEAGuidelines and as per directions of Engineer-in-Charge.

-

-

-

... More
6 A, 5 pin plate type flush/ surface mounting sockets/receptacles

350

290

101745

... More
pH analyzer

2

68827

137655

... More
Supply, installation and connection of following GI earthing strip buried individually at a depth of 500 mm including welding at joints, providing anti-corrosive paint orbitumen and jute covering for welded portion, clamping and necessary hardware forconnecting, excavation and refilling etc., including all labour and materials, as perapproved drawings, specifications of this tender and directions of Engineer-in-Charge

-

-

-

... More
Fault Isolator modules

70

573

40131

... More
5 Nos x 1.5 sq. mm

3500

88

308700

... More
Safety Supervisor As a minimum, he shall possess class XII pass certificate and trained in fire-fighting as well as in safety/occupational health related subjects, with minimum two year of practical experience in construction work environment and should have adequate knowledge of the local language spoken by majority of the workers at the construction site.

6

32000

192000

... More
Current Relay

3

2479

7438.5

... More
7 Nos x 1.5 sq. mm

1500

123

185220

... More
20A, DP MCB unit in moulded case enclosure

5

1658

8293.5

... More
Supply of 1100 V grade, Copper Conductor, Individual pair shielded & Overallshielded, twisted pair/triad, XLPE insulated, Unarmored, FRLS outer-sheathed cablesof following sizes as per EIL standard specification No. 6-51-0052, data sheets,specifications of this tender and directions of Engineer-in-Charge.

-

-

-

... More
EARTH STRIPS

-

-

-

... More
LIGHTING POLES

-

-

-

... More
TELEPHONE SYSTEM

-

-

-

... More
200X200X50X2/3MM (with SS Cover)

50

1931

96579

... More
Rubber hand gloves (11 kV grade).

2

726

1453.5

... More
50 x 6 mm

2500

346

867150

... More
Weight of the Unit upto 100 kg

5

2619

13095

... More
Providing and fixing 1.6mm thick Gl fabricated raceways in partition include providing removable 3mm thick cover with knockout holes and fixing accessories, earthingconnectivity for the complete length, including floor / wall supports, access boxes asper specification and cross over as per site requirement.

-

-

-

... More
5 Pair x 0.9 mm dia

500

119

59850

... More
Termination of XLPE insulated armoured power cables (up to 1100 V grade) and connection of leads excluding the supply of cable glands and lugs but including fixing of cable glands, supply and fixing of PVC shrouds for outdoor terminations,cutting and stripping of cable insulation, crimping the lug on to the conductor,clamping of the cable-cores, marking with wire number, ferrules etc., including alllabour and materials, as per approved drawings, specifications of this tender anddirections of Engineer-in-Charge.

-

-

-

... More
SWITCHBOARDS / UPS / VSD / BATTERY CHARGERS / PANELS

-

-

-

... More
Supply and installation of following galvanised slotted channel trays of 2 mmthickness and 50 mm high for supporting cables, including all labour and materials, asper approved drawings, specifications of this tender and directions of Engineer-inCharge.

-

-

-

... More
Certification of Data Communication System and submission of performance warranty of 20 years through OEM as per the specifications of this tender and directions ofEngineer-in-Charge

1

308700

308700

... More
Installation, testing and commissioning of switch-boards, relay and control panels,annunciation panels, UPS system, battery chargers, distribution boards, cubicles withelectrical equipment, VSD panels, misc .electrical panels etc., including transportationfrom store/yard to site at the place of installation, lifting the panels by deployment oftyre mounted hydraulic trollies, unpacking, assembly, including mounting and wiringof loose parts supplied by equipment vendor, interconnection of shipping sectionsand requisite inter-panel wiring between shipping sections, including supply of allwiring materials, installation on foundations or fixing to wall or steel structures,aligning, levelling, grouting, testing and calibration of relays and meters etc.,including all labour and materials, as per approved drawings, specifications of thistender and directions of Engineer-in-Charge.

-

-

-

... More
Type LED FD-2 Fixtures.

15

15888

238329

... More
Type LED ADMIN10 Fixtures.

5

6826

34134.3

... More
Circuit wiring in hazardous areas using (sizes given below) copper conductor, XLPEinsulated, FRLS outer sleeve armoured cables (third core for earthing) fromlighting/power panel/distribution junction box onwards, excluding the supply ofcables, junction boxes and cable glands but including fixing of cable glands, supplyand fixing of clamps, cable terminations and connections, including all labour andmaterials, as per approved drawings, specifications of this tender and directions ofEngineer-in-Charge.

-

-

-

... More
Weight of the Unit from 101 upto 500 kg.

10

4365

43650

... More
240V, 150 kVA, SPN AC UPS with bypass as per sketch-1 of 6-51-0017

1

4136400

4136400

... More
Design, Engineering, Supply of grid connected rooftop solar photovoltaic powersystem on parking area with minimum generation output of minimum 60 kWp at thepoint of common coupling with Owners switch board in Admin building (Distancebetween admin building and parking area shall be 150m tentatively). Supplied solarsystem shall comprise but not limited to solar PV modules including mounting frames,structures, array foundation, module inter connection etc, Array Junction boxes, Main Junction boxes and Fuse boxes / circuit breakers, Power Conditioning Units (PCU), ACpower evacuation panels with bus bars and circuit breakers, Metering and protection /Isolation systems, (All equipment including PCU and AC evacuation panel shall beoutdoor type), MV Power and Control Cables including end terminations, cable trays,supports & accessories, Galvanized steel conduits & accessories, PVC pipes, ferrules,lugs, glands, terminal blocks, galvanized sheet steel junction boxes, cable fixingclamps, nuts and bolts, Steel materials for field fabrication etc, other accessories forboth AC & DC power as required for interconnection between contractor suppliedequipment, Earthing system for PV Array, DC power system, AC power systemequipment, PCU etc., Lightning protection system, Data acquisition and monitoringsystem with remote monitoring facilities etc. as per EIL standard specification No. 651-0022including all labour and materials, as per approved drawings, specifications,drawingsof this tender and directions of Engineer-in-Charge.

1

2560734

2560734

... More
7 Nos x 2.5 sq. mm

1500

167

251370

... More
16/6 A, 6 pin plate type flush/ surface mounting sockets/receptacles.

500

461

230850

... More
Supply, installation, connection, testing and commissioning of following ratings of 240 V, single phase, sockets/receptacles and metallic outlet boxes as described belowincluding supply of all connected materials, including all labour and materials, as perapproved drawings, specifications of this tender and directions of Engineer-in-Charge.

-

-

-

... More
Supply of following types of FLP (II C) and WP sockets, plugs and handlamps as per EIL specification No. 6-51-0021, including all labours and materials, as per approveddrawings, specifications of this tender and directions of Engineer-in-Charge.

-

-

-

... More
Type LED ADMIN17 Fixtures.

10

84864

848643.3

... More
Hooters.

20

326

6526.8

... More
Weight of the Unit from 501 upto 1000 kg.

10

5674

56745

... More
Type LED ADMIN4 Fixtures.

6

8616

51699.06

... More
PAINTING & MARKING

-

-

-

... More
Supply and installation of dust and vermin proof G.I. sheet steel (1.6 mm thick) junction box WP type suitable for outdoor/indoor installation with number of outgoingways as under, complete with PVC connectors, supply and fixing of cable glands,including supply of required size and number of terminals, including all labour andmaterials, as per approved drawings, specifications of this tender and directions ofEngineer-in-Charge.

-

-

-

... More
Sand buckets with stand (Each with at least 3 sand buckets).

1

2693

2693.25

... More
5 Nos x 2.5 sq. mm

2500

114

286650

... More
3 C x 2.5 sq. mm

500

42

21150

... More
100 mm wide.

3000

406

1218240

... More
Type LED FD-1 Fixtures

15

9777

146664

... More
Type LED ADMIN6 Fixtures.

6

15993

95960.16

... More
240 V, 15 A, 3 pin Plugs for item no. 01EE.1060.30.70

5

3498

17493.3

... More
Fire proofing of cables including supply of all fire proofing paint, including all labour and materials, as per specifications of this tender and directions of Engineer-inCharge.(Actual area of surface painted shall be measured).

10

1088

10886.4

... More
240 V, 800A MCCB incomer with mechanical interlock

2

214884

429768

... More
Type LED IND-2 Fixtures.

300

890

267138

... More
FAJB with 1 nos 6 Pair incoming cable(s) and 6 nos 2 Pair outgoing cable(s)

2

1405

2811.06

... More
4 way.

45

2142

96422.4

... More
125 A, 2 Nos 4 pole incomer MCB isolator and 8 Nos. outgoing double pole MCBs +ELCB (32 A).

1

52704

52704

... More
Installation, testing and commissioning of weatherproof type fire alarm junction box(FAJB) suitable for outdoor installation with Krone/screw type terminals, includingtermination and connections of incoming and outgoing non-jelly cable, excludingsupply of weatherproof double compression cable glands, including all labour andmaterials, as per specifications of this tender and direction of Engineer-in-Charge.

-

-

-

... More
Wall-mounted Network Rack

-

-

-

... More
3 C x 2.5 sq. mm

5500

111

611325

... More
3 Nos x 1.5 sq. mm

2500

61

154350

... More
Temperature Sensor (for HVAC Duct) with all mounting accessories to measure thereturn air temperatures in the CSUs

5

2650

13252.5

... More
Network Active Components

-

-

-

... More
2-m long CAT-6A Patch Cord

805

359

289075.5

... More
63 A, 4 pole incomer MCB isolator and 18 Nos. outgoing single pole MCBs (upto 20A).

10

16813

168139.8

... More
Supply and Laying of PVC conduits as per the specifications of this tender anddirections of the Engineer-in-Charge.

-

-

-

... More
Type LED ST-4 Fixtures.

30

7385

221567.4

... More
Letter painting of tag nos., applicable circuit nos. for identification with red/black/white paint for all outdoor equipment in safe and hazardous areas viz. light fittings, control gear boxes, lighting/power panels, welding receptacles,convenience receptacles, local control stations, fire alarm manual call points, firealarm detectors, motors, field call stations, loud speakers, etc. including supply ofenamel paint, all hardware as required, supply of all labour, materials as per thespecification of this tender and directions of Engineer-in-Charge.

-

-

-

... More
First Aid Boxes.

1

1539

1539

... More
Structured UTP LAN CABLING

-

-

-

... More
Ambient Temp. RH sensor

1

8379

8379

... More
Installation, testing and commissioning of IP-55 and IK-10 EV charging station ratedfor 230V, 16A, 3.3kW along with installation on wall/ channel/ column, cabletermination, configuration for access the station including all labor and materialscomplete as per approved drawings, job & standard specification attached with thistender, latest IS and IEC requirements and directions of the engineer-in- charge

3

9832

29497.5

... More
Cables with OD above 40 mm but upto 50 mm.

300

45

13500

... More
Laying of cables of different voltage grade and types of the following overall diameters in ready trays/trenches/ supported on structure/pull through pipes including supplyand fixing of stainless steel strip number tags, supply and applying of fireproofingpaint to meet OISD requirement and as per IEC-60331 (for 1m length nearterminations), supply and fixing of GI saddles & saddle bars, trefoil clamps (for singlecore cables) etc., including transportation from store/yard to site at the place of installation, unpacking, including all labour and materials, as per approved drawings,specifications of this tender and directions of Engineer-in-Charge

-

-

-

... More
TDJB Surface mounting type, suitable for 1 nos 50 Pair incoming cable(s) and 50nos 2 Pair outgoing cable(s)

1

14904

14904

... More
Each alphabet/character above 4 inch and Upto 8 inch in height/length

2500

61

154350

... More
Cell Booster of adequate rating suitable for battery AH Capacity for UPS

1

238500

238500

... More
1x100% Ni-Cd Battery Bank for 30 Min backup with all accessories & battery isolator

1

4390200

4390200

... More
Supply, Installation, testing and commissioning of Sensor having both Passive Infrared(PIR) technology (occupancy) and smart day light sensing technology having highperformance along with necessary junction box, wiring, fixing arrangements andsupply of all connected materials, including programming at site, complete with alllabor and material as required as per specifications of this tender and directions ofEngineer-in-charge

175

3642

637402.5

... More
240 V, 32 A Feeder with 5kVA 240/240V Isolation Transformer along with 32A HRCFuse on primary side of isolation transformer and 32 A Isolator & semi conductor fuseon secondary side of isolation transformer along with indication lamps

5

80712

403560

... More
Type LED BK-2 Fixtures.

10

1248

12483.9

... More
BMS Server

1

511119

511119

... More
ELECTRICAL WORKS

-

-

-

... More
LIGHTING / POWER PANELS AND DISTRIBUTION BOARDS

-

-

-

... More
Supply of 1100 V grade, Copper Conductor, Individual pair shielded & Overallshielded, twisted pair/triad, XLPE insulated, Armored, FRLS outer-sheathed cables offollowing sizes as per EIL standard specification No. 6-51-0052, data sheets,specifications of this tender and directions of Engineer-in-Charge.

-

-

-

... More
Zener Barrier

2

617

1234.8

... More
SAFE AREA LIGHTING FIXTURES

-

-

-

... More
15 A, plate type flush/surface mounted switches.

450

247

111577.5

... More
Type LED ADMIN7 Fixtures.

150

672

100831.5

... More
5 Nos x 4 sq. mm

500

220

110250

... More
EARTH PLATES

-

-

-

... More
Supply of following FLP/Div.2 lighting fixtures complete with lamps, requisite FLPcable glands, plugs and necessary control gear as per EIL standard specification No. 6-51-0061, data sheet for lighting fixture schedule, including all albour and materials,specifications of this tender and directions of Engineer-in-Charge.

-

-

-

... More
Circuit wiring with 660 V grade, (sizes given below), FRLS PVC insulated copper wires in already laid surface/concealed conduit from lighting panel/power panel onwardsincluding the supply of wires, termination and connection, including all labour andmaterials, as per approved drawings, specifications of this tender and directions ofEngineer-in-Charge.

-

-

-

... More
Equipment Rack - Networking, Server

-

-

-

... More
3.3 kV grade

10

1984

19845

... More
Supply and providing of OFC cable with all required accessories like pig tail, NetworkSwitches, converters, etc.

450

260

117135

... More
Supplying, laying, termination, testing and commissioning of 4 Core 1.5 SQ. MM,unarmoured Armoured, XLPE insulated, tinned copper conductor FRLS cable -Unscreened for Command/Status/Sensor

3500

149

522025

... More
Supply, fabrication and installation of 6 mm thick M.S. chequered plate for covering floor cut- outs/cable trenches etc., including all labour and materials, as per approveddrawings, specifications of this tender and directions of Engineer-in-Charge

-

-

-

... More
240 V, 63 A Feeder with 10kVA 240/240V Isolation Transformer along with 63A HRC Fuse on primary side of isolation transformer and 63 A Isolator & semi conductor fuseon secondary side of isolation transformer along with indication lamps

20

74880

1497600

... More
3/8" dia (10 mm) flexible rope

50

129

6480

... More
Flame proof Level Switch

5

7353

36765

... More
Supply, installation and connection of following GI earthing strip along the cable trenches or cable trays or fixing to walls or structures including welding at joints,providing anti-corrosive paint or bitumen and jute covering for welded portion,clamping and necessary hardware for connecting, etc., including all labour andmaterials, as per approved drawings, specifications of this tender and directions ofEngineer-in-Charge.

-

-

-

... More
63 A, 4 pole incomer MCB isolator and 6 Nos. outgoing 32 A single pole MCBs.

2

21859

43719.84

... More
Installation, connection, testing and commissioning of following types of flame proof/Div.2 lighting fixtures and accessories, including cable termination andconnection, fixing of cable glands, lugs, including supply of necessary hardwares,including transportation from store/yard to site at the place of installation, unpacking,including all labour and materials, as per approved drawings, specifications of thistender and directions of Engineer-in-Charge.

-

-

-

... More
Wiring & ConduitingSupplying, laying, termination, testing and commissioning of signal cables. (2 core 1.5 mm2), Armoured, XLPE insulated, tinned copper conductor FRLS cable- unscreenedfor Command/Status

4000

116

467400

... More
POE Ethernet Switch

-

-

-

... More
Supply and installation of dust and vermin proof G.I. sheet steel (1.6 mm thick) junction box suitable for indoor installation, complete with 15A, 20 terminals, supplyand fixing of cable glands for incoming cable and knock outs for conduit entry foroutgoing circuits, including all labour and materials, as per approved drawings,specifications of this tender and directions of Engineer-in-Charge.

-

-

-

... More
"NOTE:- THE ABOVE RATE SHALL BE INCLUSIVE OF ALL TAXES & DUTIES, ROYALTIES, CESS, FEE, ENVIORMENTAL & POLLUTION, FITNESS & SAFETY CLEARANCE CHARGES (IF ANY), OR ANY OTHER INCIDENTAL CHARGES ETC BUT EXCLUDING GST."

-

-

-

... More
Supply, installation, connection, testing and commissioning of following types of exhaust fans including supply of all necessary supports etc., including fixing of cableglands, lugs with BEE(Bureau of Energy Efficiency) rating of minimum 3 star includingall labour and materials and accessories like mounting frame, fixing bolt, wireguard/louvres etc., as per approved drawings, specifications of this tender and directions of Engineer-in-Charge.

-

-

-

... More
Fire alarm panel.

3

5022

15066

... More
48-port CAT-6A Jack Panel (fully loaded with 48 Nos. I/Os)

19

15390

292410

... More
Supply and Laying of PVC channels as per the specifications of this tender and directions of the Engineer-in-Charge.

-

-

-

... More
Installation, testing and commissioning of miscellaneous surface mounted industrial/FLP control gear such as lighting/power panel, push button stations, motorstarter, communication equipment, junction boxes, panels, plugs, sockets, includingsupply of necessary hardware, touch up painting including supply of paint, includingtransportation from store/yard to site at the place of installation, unpacking,(excluding fixing of cable glands and cable terminations), including all labour andmaterials, as per approved drawings, specifications of this tender and directions ofEngineer-in-Charge.

-

-

-

... More
Air Flow Switch to monitor the fan status & Filter Status

30

2821

84645

... More
Supply, installation, connection, testing and commissioning of following ratings of 240V, single phase switches/MCB units, including outlet boxes and associatedaccessories, including all labour and materials, as per approved drawings,specifications of this tender and directions of Engineer-in-Charge.

-

-

-

... More
3 Nos x 2.5 sq. mm

2400

88

211680

... More
Supply of nickel plated brass single compression cable glands of following overall diameter (excluding termination and connections of cables), including drilling ofsuitable holes in equipments for fixing purposes etc., including all labour andmaterials, as per approved drawings, specifications of this tender and directions ofEngineer-in-Charge.

-

-

-

... More
Type LED ADMIN19 Fixtures

15

1894

28416.15

... More
20 A, 3 pin surface mounted industrial type switch socket with plug and sheet steel painted box.

20

1650

33003

... More
Cables with OD above 40 mm but upto 50 mm.

20

414

8290.8

... More
Ambient Air Quality Sensors

5

25650

128250

... More
Supply, installation, connection, testing and commissioning of safe arealighting/power panels, surface/flush mounting type, wall mounting type in dust tight(with hinged cover) sheet steel enclosure having 4 pole incomer and single pole MCB(9 kA type) for outgoing circuit control with complete wiring, including cabletermination, connection and fixing of cable glands, including all labour and materials,as per approved drawings, specifications of this tender and directions of Engineer-inCharge.

-

-

-

... More
Cables with OD upto 20 mm

200

123

24696

... More
Supply and application/installation of epoxy based insulation coating with breakdown voltage as per IS, suitable for system voltage as marked and shall be suitable forinstallation on concrete flooring of substation in airconditioned/non-airconditionedarea, having smooth finish, including all labour and materials, complete as perapproved drawings, job & standard specification attached with this tender anddirections of the engineer-in- charge

-

-

-

... More
Cables with OD upto 20 mm.

30

342

10260

... More
25 x 3 mm

500

194

97290

... More
Supply of IP-55 and IK-10 EV charging station rated for 230V, 16A, 3.3kW suitable for operating at a temperature of 40degrees and complete with attached socket suitable for bike charging along with lamps for indication, emergency stop pushbutton, earthleakage protection, under voltage protection, access control through RFID/ mobile appand suitable for installation on wall/ channel/ column, capable for cable terminationincluding all labor and materials complete as per approved drawings, job & standardspecification attached with this tender, latest IS and IEC requirements and directionsof the engineer-in- charge

3

78600

235800.45

... More
Supply, installation, testing and commissioning of Network Racks including all labour and materials (including Horizontal and Vertical Cable Managers) of varying sizes, asper approved drawings, specifications of this tender and directions of engineer-incharge

-

-

-

... More
T & RH Sensor (for HVAC Duct) with all mounting accessories to measure the return air temperatures in the AHUs

10

12910

129105

... More
Hooter Acknowledge Box

8

705

5644.8

... More
Cables with OD above 30 mm but upto 40 mm.

50

379

18963

... More
Supply, installation, connection, testing and commissioning of following 415 V, TPN main distribution Board (MDB) wall mounting type, dust and vermin proof with TPNincomer with voltmeter and selector switch and outgoing feeders with suitable knockouts, fixing of cable glands, lugs, terminal connectors, suitable stud for earthing, including all labour and materials, as per approved drawings, specifications of thistender and directions of Engineer-in-Charge.

-

-

-

... More
CAT-6A LSZH-FR

130

15304

1989585

... More
Lead Safety Officer Safety Officer/Engineer should possess following qualification & experience: (i) Recognized degree in any branch of Engg. or Tech. or Architecture with practical experience of working in a building or other construction work in supervisory capacity for a period of not less than two years, or possessing recognized diploma in any branch of Engg. or Tech with practical experience of working in a building or other construction work in supervisory capacity for a period of not less than five years. (ii) Recognized degree or one year diploma in Industrial safety (from any Indian Institutes recognized by AICTE or State Council of Tech. Education of any Indian State/Union territory) with at least one paper in construction safety (as an elective subject). (iii) Preferably have adequate knowledge of the language spoken by majority of the workers at the construction site. Alternately (i) Person possessing Graduation Degree in Science with Physics & Chemistry and degree or one year diploma in Industrial Safety (from any Indian institutes recognized by AICTE or State Council of Tech. Education of any Indian State/ Union Territory) with practical experience of working in a building, plant or other construction works (as Safety Officer, in line with Indian Factories Act, 1948) for a period of not less than five years, may be considered as Safety Officer.

6

65000

390000

... More
40 mm diameter

450

108

48964.5

... More
1 No. twin flat wire

200

34

6840

... More
Level transmitter

2

19152

38304

... More
Cables with OD above 20 mm but upto 30 mm.

50

202

10143

... More
With start and stop (latching type) push buttons.

2

2565

5130

... More
Supply, installation, connection, testing and commissioning of weatherproof power panels for UPS power distribution having following incomer & outgoing feeders,including all labour and materials, as per approved drawings, specifications of thistender and directions of engineer-in-charge.

-

-

-

... More
Weight of the unit above 5 kg. but upto 20 kg.

5

943

4718.7

... More
LAN SYSTEMS

-

-

-

... More
Making through and through cut outs in pockets of size 150 mm dia in the RCCfloor/walls of trenches/buildings of thickness upto 200mm for facilitation cableentries using concrete cutting machines including all labour and materials as perapproved drawings, specifications of this tender and directions of Engineer -in-charge

3

1058

3175.2

... More
32A, double pole incomer MCB isolator and 12 nos outgoing double pole 10A MCBsisolator with 2 nos, 10A semiconducting fuses ,

8

11810

94481.28

... More
Weight of the Unit from 1501 upto 3000 kg.

5

10476

52380

... More
Supply, installation, testing (Penta Scanning) and commissioning of Structured UTP LAN Cabling including all labour and materials (Cable, Conduit, Channel), includingfollowing items as per approved drawings, specifications of this tender and directionsof engineer-in-charge:

-

-

-

... More
Junction box.

5

2332

11664

... More
Total No. of Gigabit UTP Ports 24 No. of POE Ports 24 No. of Fiber Ports 4

4

139622

558489.6

... More
Supply and installation of prefabricated hot dip galvanised steel cable trays, fabricated out of hot rolled sheet steel with rigid welded construction ladder type with a rung asper std. 7-51-0333, of approved make and cable tray fittings, including all labour andmaterials, as per approved drawings, specifications of this tender and directions ofEngineer-in-Charge.

-

-

-

... More
Weight of the unit up to 5 kg.

5

520

2601.9

... More
100 x 12 mm

100

727

72756

... More
63A, double pole incomer MCB isolator and 18 nos outgoing double pole 10A MCBsisolator with 2 nos, 10A semiconducting fuses

5

13442

67214.7

... More
Cables with OD above 50 mm but upto 60 mm.

20

564

11289.6

... More
Lead Electrical Engineer Qualification Criteria: Degree or Diploma in Electrical Engineering with following experience- Degree holders : 10 yrs of construction experience Diploma holders : 13 yrs of construction experience

12

65000

780000

... More
40 A, 4 pole incomer MCB isolator and 12 Nos. outgoing single pole MCBs (upto 20 A).

40

13871

554878.8

... More
INSTRUMENTATION

-

-

-

... More
100mmX50mmX2mm Supply and laying of prefabricated Anodized AluminumPerforated cable tray

400

665

266380

... More
Supply of Industrial, weather proof type Push Button stations as per EIL specification No. 6-51-0014, as per approved drawings, specifications of this tender and directionsof Engineer-in-Charge.

-

-

-

... More
3-way, junction box.

2

360

720

... More
25 x 3 mm

4000

118

473760

... More
Each alphabet/character above 2 inch and Upto 4 inch in height/length

4000

52

211680

... More
Supply and laying of following sizes of G.I. Pipes (medium) in required length fixed on steel, concrete or similar structure, laid in trenches, ready to be buried in concreteincluding cutting, threading, bending and similar works, supply of clamps, small ironstructures, spacers and installation of seats, plugs, bushings etc., small civil works,including all labour and materials, as per approved drawings, specifications of thistender and directions of Engineer-in-Charge

-

-

-

... More
Supply and Laying of PVC conduits of sizes OD 50 mm

8000

245

1965600

... More
JUNCTION BOXES (OUTDOOR / INDOOR TYPE)

-

-

-

... More
TDJB Surface mounting type, suitable for 1 nos 20 Pair incoming cable(s) and 2nos 20 Pair outgoing cable(s)

1

12420

12420

... More
415 V, 63A MCCB feeder as per datasheet B378-999-16-50-DS-1821

6

71208

427248

... More
3 Nos. twin flat wires.

100

51

5130

... More
Connecting individual equipment to the earth strip or earth plate with following sizes of G.I. wire / G.I. wire rope including the supply of G.I. wire /G.I. wire rope, lugs,conductors, connecting to the G.I. strip or earth plate and necessary hardware forconnection, including all labour and materials, as per approved drawings,specifications of this tender and directions of Engineer-in-Charge.

-

-

-

... More
Type LED ADMIN8 Fixtures.

30

3692

110783.7

... More
Supply, installation, mounting, testing and commissioning of Ethernet Edge Switch(s) including all labour and materials, as per approved drawings, specifications of thistender and directions of engineer in charge

-

-

-

... More
3 C x 4 sq. mm

200

30

6080

... More
32A, double pole incomer MCB isolator and 6 nos outgoing double pole 10A MCBsisolator with 2nos, 10A semiconducting fuses

3

9365

28095.66

... More
2.5 sq. mm wires.

5000

52

264600

... More
8 SWG GI Wire.

500

25

12960

... More
Smoke Sensors

5

5677

28386

... More
Cables with OD above 30 mm but upto 40 mm.

20

314

6285.6

... More
450 mm dia., 1 phase, 900 rpm, wall mounting type epoxy painted exhaust fan withlouvres suitable for Gas group IIC, temperature class T3.

3

5950

17852.4

... More
Supply, installation and connection of GI earth plates as per std. 7-51-0103, complete with anchor bolts, including all labour and materials, as per approved drawings,specifications of this tender and directions of Engineer-in-Charge.

-

-

-

... More
Supply and installation of fire proof sealing system as per IEC-60332 including supply and fabrication of steel frames and other accessories (cement, gravel, sand etc.)including drilling, cutting, welding, surface preparation, dressing/ chipping ofconcrete, enlargement etc. including all minor masonry and structural works andrepair of all damages in line with the enclosed job specification and instructions of theEngineer-in-Charge

1

42750

42750

... More
Weight of the Unit from 1001 upto 1500 kg.

5

6984

34920

... More
Float Level Switch

5

6583

32917.5

... More
True RMS Digital Multimeter with Display of up to 3 digits of decimal

1

19665

19665

... More
2 Winding Dry type transformers. .415 kV / .415 kV 50 kV·A

2

11025

22050

... More
Type LED ADMIN12 Fixtures.

60

6276

376612.2

... More
FIRE ALARM SYSTEM

-

-

-

... More
300X300X50X2/3MM (with SS Cover)

25

2610

65268

... More
50 x 50 x 2 mm Supply and laying of prefabricated Anodized Aluminum Perforated cable tray

1500

473

709650

... More
Supply of 1100 V grade, Copper Conductor,XLPE insulated and armoured, cables offollowing sizes as per EIL standard specification No. 6-51-0051, data sheets,specifications of this tender and directions of Engineer-in-Charge.

-

-

-

... More
Central Computer SystemMulticore 3rd Gen XEON Processor, 16GB RAM, RAID-10 Hard Disk with 4TB capacity(SSD+HDD), 27full HD Monitor, Parallel Port & Serial Port, Wired Keyboard Mouse,Windows server 2022 x 64 or Windows 10 x 64, MS Office with Antivirus software

1

116478

116478

... More
100 mm NB.

180

2116

381024

... More
Sensors & Field DevicesSupply, installation, testing and commissioning of the following sensors/ transducers/transmitters

-

-

-

... More
Supply and laying of 900 mm wide safety insulation mats complying to IS-15652, of following grades required for maintenance of electrical equipment in substation,including cutting to required shape in running length, including all labour andmaterials, as per applicable Indian or International standards and CEA Guidelines andas per directions of Engineer-in-Charge.

-

-

-

... More
Installation, termination and connection of following fire alarm panel including Power Pack and battery backup system and all associated items, including transportationfrom store/yard to site at the place of installation, assembling and installation onfoundation or fixing to wall or steel structures, aligning, levelling, grouting,termination and connection of cables, making earth connections etc., including alllabour and materials, as per approved drawings, specifications of this tender anddirections of Engineer-in-Charge

-

-

-

... More
Providing the following personel to BANDR with required experience and qualification for the purpose of BANDR's work on monthly basis. Note: 1. Contractor shall pay the wages, ESI and EPF to the personel mentioned below. 2. Contractor shall be capable to pay the wages as per tender document timely before 10th of every month from his own resources. 3. The contractor shall be liable for any issues arising in relation to EPF, ESI and shall deal with it taking responsibility of the related procedures. 4. The Contractor has to submit the CV/Resume/Bio-data of the peronel to be deployed for BANDR's works and shall deploy the personel only after approval of Engineer-in-Charge. 5. In case, the person employed by the contractor commits any act of omission/commission that amounts to misconduct/indiscipline/ incompetence, the contractor shall be liable to take appropriate disciplinary action against such persons, including their removal from the site of work. 6. The Contractor shall replace immediately any of its personnel found unacceptable to this office because of security risks, incompetence, conflict of interest, improper conduct etc. upon receiving a notice 7. This item is for sole purpose of BANDR's work and not for contractor's work. This item does not relieve the contractor's responsibility to bring the manpower required to execute their own work awarded.

-

-

-

... More
2 Pair x 1.5 sq. mm

7000

145

1017450

... More
Type LED ADMIN1 Fixtures.

15

3753

56308.5

... More
Cables with OD above 50 mm but upto 60 mm

10

567

5674.5

... More
Type LED 3 Fixtures.

150

855

128331

... More
Supplying, laying, termination, testing and commissioning of Cat 6 cable for busconnection- for Integration / controllers

1000

92

92150

... More
FAJB with 1 nos 6 Pair incoming cable(s) and 6 nos 2 Pair outgoing cable(s)

2

9148

18297

... More
415 V, 3 Phase, TPN, 50Hz, 160A, 25kA (1Sec) switchboard with 1 no. 160A incomerMCCB incomer and 10 nos. 63A outgoing MCCB + ELCB feeders. Incomer shall havevoltmeter and ammeter with selector switches and outgoing feeders shall haveammeter with selector switch

1

829350

829350

... More
Water Flow switch

2

5130

10260

... More
Shock hazard charts complete with frame and glass.

1

1154

1154.25

... More
Type LED ADMIN11 Fixtures

60

2811

168663.6

... More
Providing and fixing 2 mm thick G.I. fabricated junction box in raceways includeproviding removable 3mm thick cover with knockout holes and fixing accessories,earthing connectivity for the box, including floor / wall supports, access boxes as perspecification and cross over as per site requirement

-

-

-

... More
Civil QA/QC Officer Qualification Criteria: Degree or Diploma in Engineering with following experience- Degree holders : 10 yrs of construction experience of which minimum 3 years in QA/QC Diploma holders : 13 yrs of construction experience of which minimum 6 years in QA/QC

-

-

-

... More
SoftwareGraphical interface software. The system should be accessible from anywhere on LANor WAN or Ethernet. The Communication protocol shall be one of the IndustryStandard Open Protocols such as BACNet, LONWORKS etc. System should be scalableand should have minimum 2 clients and should fully compliant to the detailedtechnical specifications as per the tender

1

1069605

1069605

... More
Flush Mounting Type

25

521

13041

... More
Break glass type fire alarm boxes

40

661

26460

... More
Supply and Laying of PVC channels

-

-

-

... More
EV Charging Stations

-

-

-

... More
EMERGENCY LIGHTING

-

-

-

... More
2 Nos. twin flat wires.

150

42

6412.5

... More
Type LED ADMIN9 Fixtures

2

25465

50930.82

... More
END TERMINATIONS

-

-

-

... More
SENSORS

-

-

-

... More
Installation, testing and commissioning of Uninterruptable Power Supply (UPS) System along with associated battery banks (Ni-Cd Battery), battery charger, cell booster andall equipment supplied as a part of UPS system as per item 01EE.MA01 along withaccessories of complete equipment, including transportation from store/yard to site atthe place of installation, lifting the panels by deployment of tyre mounted hydraulictrollies, unpacking, assembly, including mounting and wiring of loose parts suppliedby equipment vendor, interconnection of shipping sections and requisite inter-panelwiring between shipping sections, including supply of all wiring materials, installationon foundations or fixing to wall or steel structures, aligning, levelling, grouting,testing and calibration of relays and meters etc., and filling with electrolyte inbatteries, aligning, levelling, grouting, assembly of battery racks, fixing of inter-cellconnectors etc including all labour and materials, as per approved drawings,specifications of this tender and directions of Engineer-in-Charge

1

429534

429534

... More
Installation, Testing and commissioning of grid connected rooftop solar photovoltaicpower system as per complete MR item 01EE.MA03.02, including Earthing system,Lightning protection system, configuration of Data acquisition and monitoring systemwith remote monitoring facilities etc and laying and termination of cable within allequipments supplied as a part of this solar system and from PCU/AC Power evacuationpanel to 415V Main distribution board in admin building (tentative distance of 150m)and all other items as per EIL standard specification No. 6-51-0022 including alllabour and materials, as per approved drawings, specifications, drawings of thistender and directions of Engineer-in-Charge.

1

122863

122863.5

... More
6 mm thick M.S. chequered plate.

15

3572

53581.5

... More
300 mm dia., 1 phase, 900 rpm, wall mounting type epoxy painted exhaust fan with louvres.

100

3702

370215

... More
Certification of Data Communication System

-

-

-

... More
25 mm diameter

2850

126

361665

... More
Supply and installation of 50 mm x 50 mm, (18 SWG) 'METSEC' channel with removable cover, including supply of all connected hardware, supports, all labour and materials,as per approved drawings, specifications of this tender and directions of Engineer-inCharge.

6175

490

3029949

... More
LAYING OF COMMUNICATION / FIRE ALARM CABLES

-

-

-

... More
Water Flowmeter

2

37791

75582

... More
Cables of overall dia. upto 35 mm.

8000

25

200880

... More
SOCKETS / RECEPTACLES AND SWITCHES / MCB UNITS

-

-

-

... More
Supply of weatherproof type fire alarm junction box (FAJB) suitable for outdoorinstallation with Krone/screw type terminals, including supply of weatherproof doublecompression cable glands and weatherproof plugs to block the unused entry includingall labour and materials, as per specifications of this tender and direction of Engineerin-Charge

-

-

-

... More
40 mm diameter

950

245

233073

... More
Type LED SFD-12 Fixtures.

20

1746

34920

... More
100 x 12 mm

100

736

73602

... More
Cables with OD above 50 mm but upto 60 mm.

300

63

18900

... More
415 V, 125A MCCB buscoupler as per datasheet B378-999-16-50-DS-1814

1

108675

108675

... More
Each alphabet/character upto 2 inch in height/length

4000

44

176400

... More
Supply, installation, testing and commissioning of Indoor Telephone Distribution J.B. made out of 2.03 mm (14 gauge) sheet steel, with one anti-rust coat of primer, withtwo finished coats of approved epoxy paint, with Krone type terminals with hingedlockable door, detachable gland plate at the bottom/top complete with terminationand connections of incoming/ outgoing cables, including all labour and materials, asper specifications of this tender and directions of Engineer-in-Charge.

-

-

-

... More
40 A, 4 pole incomer MCB isolator and 6 Nos. outgoing single pole MCBs (upto 20 A).

12

11349

136188

... More
Horizontal and vertical laying/pulling through of communication/fire alarm cables ofthe following overall diameters in ready trays/trenches/conduits or supported onstructures including supplying and fixing of GI saddle and saddle bars, stainless steelstrip number tags, including transportation from store/yard to site at the place ofinstallation, unpacking, including all labour and materials, as per approved drawings,specifications of this tender and directions of Engineer-in-Charge

-

-

-

... More
50 mm NB.

225

1058

238140

... More
CABLE - TRAYS

-

-

-

... More
PLUGS, SOCKETS AND JUNCTION BOXES

-

-

-

... More
WIRING

-

-

-

... More
Multi sensor type detectors

800

476

381024

... More
1-m long CAT-6A Patch Cord

805

278

224071.75

... More
Output/Control Relay Module

20

705

14112

... More
Type LED ADMIN3 Fixtures.

120

7141

856936.8

... More
Design, Engineering, Supply of grid connected rooftop solar photovoltaic power system with minimum generation output of minimum 125 kWp at the point ofcommon coupling with Owners switch board in Admin building. Supplied solar systemshall comprise but not limited to solar PV modules including mounting frames,structures, array foundation, module inter connection etc, Array Junction boxes, MainJunction boxes and Fuse boxes / circuit breakers, Power Conditioning Units (PCU), ACpower evacuation panels with bus bars and circuit breakers, Metering and protection /Isolation systems, MV Power and Control Cables including end terminations, cabletrays, supports & accessories, Galvanized steel conduits & accessories, PVC pipes,ferrules, lugs, glands, terminal blocks, galvanized sheet steel junction boxes, cablefixing clamps, nuts and bolts, Steel materials for field fabrication etc, otheraccessories for both AC & DC power as required for interconnection betweencontractor supplied equipment, Earthing system for PV Array, DC power system, ACpower system equipment, PCU etc., Lightning protection system, Data acquisition andmonitoring system with remote monitoring facilities etc. as per EIL standardspecification No. 6-51-0022 including all labour and materials, as per approveddrawings, specifications, drawings of this tender and directions of Engineer-inCharge.

1

5007420

5007420

... More
Circuit wiring in non-hazardous areas using (size given below), copper conductor,XLPE insulated, FRLS outer sleeve cables (third core for earthing), from lighting/power panel/distribution junction box, excluding the supply of cable, junction boxes andcable glands but including termination and connection, including all labour andmaterials, as per approved drawings, specifications of this tender and directions ofEngineer-in-Charge.

-

-

-

... More
3 C x 4 sq. mm

1000

136

136800

... More
CABLE GLANDS

-

-

-

... More
Type LED HB-1 Fixtures.

20

14841

296820

... More
100 A, incomer MCCB and 8 Nos. 40 A outgoing TPN MCBs

1

54649

54649.8

... More
450 mm wide Straight run cable tray.

200

837

167508

... More
Type LED IND-1 Fixtures.

175

558

97776

... More
Supply of IP-55 and IK-10 EV charging station rated for 230V, 32A, 7.4kW suitable foroperating at a temperature of 40degrees and complete with attached Type-2connector cable of 5m length suitable for car charging along with lamps for indication,emergency stop pushbutton, earth leakage protection, under voltage protection,access control through RFID/ mobile app and suitable for installation on wall/channel/ column, capable for cable termination including all labor and materialscomplete as per approved drawings, job & standard specification attached with thistender, latest IS and IEC requirements and directions of the engineer-in- charge

3

98496

295488

... More
Supply, installation, testing and commissioning of following energy efficient lighting fixtures and connecting to wiring junction box/marshalling box complete with lampsand necessary control gear including supply of all connected materials like flexibleconduit, clamps, supports, chains, anchor fastners, bolts, nuts and washers etc. asrequired, including supply and fixing of cable glands, lugs, including all labour andmaterials, as per approved drawings, data sheet for lighting fixture schedule, EILinstallation standards, specifications of this tender and directions of Engineer-inCharge.

-

-

-

... More
Type LED ADMIN13 Fixtures.

5

6276

31384.35

... More
55" LCD Display Screen (Resolution 1920x1080 Full HD or better) to display AirQuality

1

190440

190440

... More
Cables with OD upto 20 mm.

2000

18

36000

... More
240 V, 15 A, 3 pin socket.

5

6001

30006.45

... More
Type LED FD-9 Fixtures.

25

35443

886095

... More
EARTHING CONNECTION

-

-

-

... More
Supply and laying of (concealed type) PVC conduit of following diameter and associated fittings in brick walls, RCC slabs/ceilings for lighting/ power/telephone,fire alarm/plant communication points etc., including supply of G.I. sheet steeljunction boxes with acrylic cover, pull wire, making cuts and chasis in built up brickwork, RCC slabs/ceilings and making good the same, including all labour andmaterials, as per approved drawings, specifications of this tender and directions ofEngineer-in-Charge.

-

-

-

... More
Electrical Protection suit

1

59850

59850

... More
Type LED ADMIN5 Fixtures

30

6399

191972.7

... More
Installation, Testing and commissioning of grid connected rooftop solar photovoltaicpower system as per complete MR item 01EE.MA03.01 including Earthing system,Lightning protection system, configuration of Data acquisition and monitoring systemwith remote monitoring facilities etc and laying and termination of cable within allequipments supplied as a part of this solar system and from PCU/AC Power evacuationpanel to 415V Main distribution board in admin building and all other items as per EILstandard specification No. 6-51-0022 including all labour and materials, as perapproved drawings, specifications, drawings of this tender and directions of Engineerin-Charge.

1

240255

240255

... More
STRUCTURAL STEEL

-

-

-

... More
Supply and Laying 3C X 2.5 SQ mm Armored Power cable for DDC's , Integrators

500

159

79800

... More
Type LED ADMIN15 Fixtures.

30

18455

553656.6

... More
Lighting poles including supply and connection of wires upto fixtures for safe areas.

10

15876

158760

... More
Tee Joints for 450 mm wide tray with 1000 mm bending radius.

5

3426

17131.5

... More
Wiring with (No. of wires given below) 660 V grade, 0.63 mm dia. annealed tinned copper conductor, PVC insulated twin flat wire as per relevant IS in already laidsurface/concealed conduit from TDJB onwards to telephone sockets including supplyof Wires, termination and connection, including all labour and materials, as perapproved drawings, specifications of this tender and directions of Engineer-in-Charge

-

-

-

... More
Cables with OD above 20 mm but upto 30 mm.

2000

27

54000

... More
G.I. & PVC PIPES

-

-

-

... More
Supply, installation, connection, testing and commissioning of 240 V AC, 1200 mmsweep ceiling fan with regulator (labeled as minimum 3-star by Bureau of EnergyEfficiency)including providing clamp/hook in RCC slab, if necessary, providing, fixing,ceiling, rose, wiring, including all labour and materials, as per approved drawings,specifications of this tender and directions of Engineer-in-Charge.

75

2470

185321.25

... More
Heat detectors

10

238

2381.4

... More
Supply and installation of Lighting Poles for floor mounting as per std. 7-51-0201,including all civil works, excavation, foundation, disposal of surplus earth, providingshoring, strutting and dewatering if required and including supply of cement, steel, GIpipes, base plates, paint and all sundry materials as required, including painting,(excluding supply and installation of control gear box/junction box), but including alllabour and materials, as per approved drawings, specifications of this tender anddirections of Engineer-in-Charge.

-

-

-

... More
Type LED 1 Fixtures.

400

4653

1861236

... More
EARTH ELECTRODES

-

-

-

... More
TRANSFORMERS

-

-

-

... More
Supply and installation of Lighting Poles for floor mounting as per std. 7-51-0201 along with Single overhang circular decorative arms of 1 mtr length one side. TheDecorative arm should support suspended mounting of the LED Drop Down Post Top.The circular arm should be properly welded to the pipe by means of 3 segments. Adecorative embellishment knob at the top of pole and a designer element shall beprovided on the arm for aesthetics and all civil works, excavation, foundation, disposalof surplus earth, providing shoring, strutting and dewatering if required and includingsupply of cement, steel, GI pipes, base plates, paint and all sundry materials as required, including painting, including supply and installation of control gearbox/junction box, cable termination upto lamp via junction box and all labour andmaterials, as per approved drawings, specifications of this tender and directions ofEngineer-in-Charge.

2

19237

38475

... More
Type LED 6 Fixtures.

60

855

51332.4

... More
Installation, testing and commissioning of dry transformer of following rating,including transportation from store/yard to site at the place of installation, unpacking,positioning in place, site assembly of loosely furnished accessories, connection ofauxiliary circuits, including fixing of nuts and bolts etc., including all labour andmaterials, as per approved drawings, specifications of this tender and directions ofEngineer-in-Charge

-

-

-

... More
Diesel Flow Meter flameproof

2

150736

301473

... More
Electrical Engineer Qualification Criteria: Degree in Electrical Engineering with minimum 2 years of relevant experience in construction or Diploma in relevant Engineering Discipline with minimum 4 years of relevant experience in Construction.

12

45000

540000

... More
Supply of dry type transformers with accessories, including nuts and bolts etc., as per EIL standard specification No. 6-51-0042, including all labour and materials, as perapproved drawings, specifications of this tender and directions of Engineer-in-Charge

-

-

-

... More
As per std. 7-51-0307

25

2332

58320

... More
LAYING OF CABLES

-

-

-

... More
Exit signs

60

326

19580.4

... More
CIVIL WORKS/M.S. CHEQUERED PLATE

-

-

-

... More
Type FLP-IIC-12 Fixtures.

20

11568

231363

... More
32A, DP MCB unit in moulded case enclosure for window / split type air conditioner.

5

1598

7994.25

... More
DDC ControllerStandalone and BACnet IP Networkable 32 Bit or more , 32 MB RAM 1GHZ DDCControllers with I/O module as per tentative IO List of Points attached with the tender.The controllers shall be capable of 3 No's of RS485 for Modbus/BACnet MSTPIntegration ,standalone operation with real time clock and historical database. TheDDC's shall be capable of peer to peer communication without help of systeminterface controller or PC. The DDCs shall be with suitable IP 67 enclosure completewith all wiring and accessoriesDDC-Plant RoomDDC-ChillerDDC-Air Handling Units & Fans with BasementDDC-HT & LT PanelDDC-DG

1

6211489

6211489.5

... More
ROOFTOP SOLAR PHOTOVOLTAIC SYSTEM

-

-

-

... More
Flame proof Level transmitter

2

20776

41553

... More
Immersion Temperature Sensor with Well

5

3078

15390

... More
Supply of 240V, 800A, TPN, indoor fixed type, 25kA (min) for 1 Sec. Al. Bus-bar switch board, single front, free standing floor mounted, bottom cable entry, metalenclosed switchboards suitable for operation at indoor site conditions with followingfeeders complete with meters, alarms, controls, protections etc. as per tenderSpecification 6-51-0017, job specification, hard-ware datasheets, componentdatasheet, other codes and standards attached or referred, including supply of allcommissioning spares, special tools and tackles & documentation, includingtransport, all labor and materials, as per approved drawings, specifications of thistender and directions of Engineer-in- Charge, complete in all respects.

-

-

-

... More
Post top lantern.

30

5953

178605

... More
Water Differential Pressure Switch

5

5643

28215

... More
INFORMATION TECHNOLOGY SERVICES

-

-

-

... More
Input/Monitoring relay module

10

705

7056



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.