Bridge And Roof Company India Limited Tender

Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.

Bridge And Roof Company India Limited Tender

Works
Energy, Oil and Gas
Electrical Generators And Transformers
Electrical and Electronics
Electrical Works
Eprocure
Opening Date30 Nov 2024
Closing Soon30 Dec 2024
Tender Amount₹ 15,33,32,063 
This is an estimated amount, exact amount may vary.
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply, installation, testing and commissioning of MOV JB

-

-

-

... More
Supply, installation, termination of incoming/outgoing cables , testing & commissioning of FLP type MOV JB suitable for installation in Zone-2, gas group IIA/IIB, T3, 60 terminals suitable for 5 nos. 6PX1.5sq.mm Overall shielded, twisted pair , XLPE insulated and armoured outgoing cables and 2 nos. 12PX1.5sq.mm Overall shielded, twisted pair , XLPE insulated and armoured incoming cables including supply & fixing of flame proof cable glands & lugs, terminal connectors, suitable stud for earthing, including all labour and materials as per attached EIL standard specification, approved drawings, specifications of this tender & directions of Engineer-in-Charge

2

18437

36874

... More
Supply, installation, testing and commissioning of HV switchboard(6.6kV) extension panel at APU Substation.

-

-

-

... More
Supply, transportation, storage, Installation, testing & commissioning of 6.6KV, 3000A, 40KA for 1 sec CU bus bar with HT sleeved, 50Hz HV Switchboard extension panel (OEM MAKE: ABB ) in existing switchboard (HT-201), (1 panel on LHS and 1 panel on RHS) for RG compressors including MFM, MPR and hook up with existing ECS system, protection CTs, protection relays (numerical) along with mapping with existing sytem with breaker status and other signal as per existing philosophy/system architecture (existing scheme dwg. YN1V300013-AZX-MF) , metering including CTs, PTs, MCBs/fuses, selector switches, components, I/O cards, associated wiring etc., as applicable. Supply & mounting of all hardware, components, accessories & material as required for feeders and including panel installation on existing substation floor by making suitable cutout through floor cutting/ core cutting, as applicable including all labour & material complete as per the enclosed specification 6-51-0001, HV switchboard data sheets B650-000-16-50-DS-3001, Scope of work/ job specification (B650-000-16-50-SOW-3001), and other codes and standards attached or referred for following feeders: 6.6kV, 1250A Outgoing motor feeder complete with motor protection relay (DOL motor feeder) suitable for IEC- 61850 protocol. (Separate earthing carriage/ truck shall be supplied (the rates inclusive of packing and transportation) for cable side and bus side earthing for the HV Switchboards. One set of earthing truck for bus side earthing and one set for cable side earthing shall also be provided.)

2

1989611

3979222

... More
Supply, installation, testing and commissioning of extension panel of existing PC-301 at APU substation.

-

-

-

... More
Supply, transportation, storage, Installation, testing & commissioning of 0.415KV, 2500A, 50HZ, 50KA for 1 sec MV Switchboard extension panel in existing switchboard (PC-301), (1 panel on LHS and 1 panel on RHS) including adaptor panel, MFM, and hook up with existing ECS system, protection CTs, protection relays (numerical) along with mapping with existing system with breaker status and other signal as per existing philosophy/system architecture, metering including CTs, PTs, MCBs/fuses, selector switches, components, I/O cards, associated wiring etc., as applicable. Supply & mounting of all hardware, components, accessories & material as required for feeders and including panel installation on existing substation floor by making suitable cutout through floor cutting/ core cutting, as applicable including all labour & material complete as per the enclosed specification 6-51-0018, MV switchboard data sheets B650-000-16-50-DS-3002, Scope of work/ job specification (B650-000-16-50-SOW-3001), and other codes and standards attached or referred for following feeders: 0.415kV, 800A Outgoing breaker feeder complete with metering and protection relay suitable for IEC- 61850 protocol.

2

349055

698110

... More
Installation, testing and commissioning of bus ducts of following ratings between transformer secondary and the switchgear incomer panel, including transportation from store/yard to site at the place of installation, unpacking, making connections and installation of bends, breaking of walls and making good of the same etc., (including structural supports), including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge.

-

-

-

... More
Air Insulated/segregated bus ducts 6.6 V 2500 A 40 kA for 1 second

60

20218

1213080

... More
Supply of push buttons

-

-

-

... More
Supply of FMR push button stations (spring return type with enclosure), Green colour, Explosion proof type Ex-d (suitable for zone-2, gas group: IIA/IIB), Temperature class: T3. with ingress protection of IP:65 complete with mounting accessories like U-clamp, bolts & nuts suitable for mounting in 2'' pipe, tamper proof cover, etc as per EIL standard specification 6-51-0006, approved drawings, tender specification and instructions of Engineer-in- charge.[ push buttons shall be with 2 NO+2NC and the contact rating shall be 1A, 24VDC]

22

4475

98450

... More
Supply of close push button stations ( break the contact when activated and contact shall be momentary type), Red colour, Explosion proof type Ex-d type suitable for zone-2, Gas group IIA/IIB, Temperature class: T3 with ingress protection of IP:65 complete with mounting accessories like U clamp, bolts & nuts suitable for mounting in 2'' pipe, tamper proof cover, etc as per EIL standard specification 6-51-0006, approved drawings, specification and instructions of Engineer-in-charge.[ push buttons shall be with 2 NO+2NC and the contact rating shall be 1A, 24VDC]

5

4618

23090

... More
Supply of emergency push button with break glass( push type with mushroom head, push to shutdown stay put type & push button shall break the contact when activated, rotate to release) , red colour, Explosion proof type Ex-d suitable for Zone-2 GAs group: IIA/IIB), Temperature class: T3. with ingress protection of IP:65 complete with mounting accessories U-clamp, bolts & nuts suitable for mounting in 2'' pipe, protective cover with breakable glass etc as per EIL standard specification 6-51-0006, as per approved drawings, tender specification and instructions of Engineer-in-charge. [ push buttons shall be with 2 NO+2NC and the contact rating shall be 1A, 24VDC]

16

9514

152224

... More
Supply of bus ducts (6.6V, 2500A, 40 kA for 1sec. Bus Duct as per datasheet number (B650- 000-16-50-DS-0041). [Heat run test shall be conducted on the offered bus duct and price for the same shall be included in base price of bus duct.)

-

-

-

... More
Supply of Bus ducts for outdoor installation, including all horizontal an vertical bends , copper flexible etc as required

40

134789

5391560

... More
Supply of Bus ducts for indoor installation, including all horizontal an vertical bends , copper flexible etc as required.

20

127978

2559560

... More
Supply of Switchboard end termination with all accessories such as copper flexible, matching flanges, gaskets, nuts, bolts etc.

4

194173

776692

... More
Supply of Transformer end termination with all accessories such as copper flexible, matching flanges, gaskets, nuts, bolts etc.

4

194173

776692

... More
Supply, installation and connection with CU earth plate.

-

-

-

... More
Supply, installation and connection of CU earth plates ( 380x45x10) size, complete with anchor bolts, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in- Charge.

5

5728

28640

... More
Addition/deletion of drawout type switchboard ( for MCC-306)

-

-

-

... More
Supply of empty panel ( 800A) bus bar for drawout type switchboard (for MCC-306).

1

154479

154479

... More
Installation, testing and commissioning of empty panel ( 800A) bus bar for drawout type switchboard ( for MCC-306).

1

15448

15448

... More
Supply of FVNR-15 feeder as per feeder datasheet B650-000-16-50-DS-3010 SHT-3 and component datasheet B650-000-16-50-DS-3009 for drawout type switchboard.

1

64844

64844

... More
Installation, testing and commissioning of FVNR-15 feeder as per feeder datasheet B650-000-16-50-DS-3010 SHT-3 and component datasheet B650-000-16-50-DS-3009 for drawout type switchboard.

1

6489

6489

... More
Supply of FVNR-30 feeder as per feeder datasheet B650-000-16-50-DS-3010 SHT-5 and component datasheet B650-000-16-50-DS-3009 for drawout type switchboard

1

81061

81061

... More
Installation, testing and commissioning of FVNR-30 feeder as per feeder datasheet B650-000-16-50-DS-3010 SHT-5 and component datasheet B650-000-16-50-DS- 3009 for drawout type switchboard.

1

8109

8109

... More
Supply of FVNR-60 feeder as per feeder datasheet B650-000-16-50-DS-3010 SHT-7 and component datasheet B650-000-16-50-DS-3009 for drawout type switchboard

1

97270

97270

... More
Installation, testing and commissioning of FVNR-60 feeder as per feeder datasheet B650-000-16-50-DS-3010 SHT-7 and component datasheet B650-000-16-50-DS-3009 for drawout type switchboard

1

9729

9729

... More
Supply of FVNR-100 feeder as per feeder datasheet B650-000-16-50-DS-3010 SHT- 8 and component datasheet B650-000-16-50-DS-3009 for drawout type switchboard

1

118884

118884

... More
Installation, testing and commissioning of FVNR-100 feeder as per feeder datasheet B650-000-16-50-DS-3010 SHT- 8 and component datasheet B650-000-16-50-DS-3009 for drawout type switchboard.

1

11895

11895

... More
Supply of FVNR-150 feeder as per feeder datasheet B650-000-16-50-DS-3010 SHT- 9 and component datasheet B650-000-16-50-DS-3009 for drawout type switchboard.

1

134252

134252

... More
Installation, testing and commissioning of FVNR-150 feeder as per feeder datasheet B650-000-16-50-DS-3010 SHT- 9 and component datasheet B650-000-16-50-DS-3009 for drawout type switchboard.

1

13425

13425

... More
Supply of SFU-63 feeder as per feeder datasheet B650-000-16-50-DS-3010 SHT- 6 and component datasheet B650-000-16-50-DS-3009 for drawout type switchboard

1

27119

27119

... More
Installation, testing and commissioning of SFU-63 feeder as per feeder datasheet B650-000-16-50-DS-3010 SHT- 6 and component datasheet B650-000-16-50-DS-3009 for drawout type switchboard

1

2712

2712

... More
Supply of SFC-63 feeder as per feeder datasheet B650-000-16-50-DS-3010 SHT- 4 and component datasheet B650-000-16-50-DS-3009 for drawout type switchboard

1

25338

25338

... More
Installation, testing and commissioning of SFC-63 feeder as per feeder datasheet B650-000-16-50-DS-3010 SHT- 4 and component datasheet B650-000-16-50-DS-3009 for drawout type switchboard

1

2533

2533

... More
Supply of SFC-100 feeder as per feeder datasheet B650-000-16-50-DS-3010 SHT- 10 and component datasheet B650-000-16-50-DS-3009 for drawout type switchboard

1

44393

44393

... More
Installation, testing and commissioning of SFC-100 feeder as per feeder datasheet B650-000-16-50-DS-3010 SHT- 10 and component datasheet B650-000-16-50-DS-3009 for drawout type switchboard

1

4439

4439

... More
Supply of SFC-250 feeder as per feeder datasheet B650-000-16-50-DS-3010 SHT- 11 and component datasheet B650-000-16-50-DS-3009 for drawout type switchboard

1

68155

68155

... More
Installation, testing and commissioning of SFC-250 feeder as per feeder datasheet B650-000-16-50-DS-3010 SHT- 11 and component datasheet B650-000-16-50-DS-3009 for drawout type switchboard

1

6820

6820

... More
Miscellaneous

-

-

-

... More
Disconnection, dismantling of existing OLTC at LPG -1 & LPG-2 substation, transportation of the same to Owner's warehouse/store within the plant premises for a distance of upto 2 km including all labour and materials, as per the job specifications, EIL standard specifications and as per directions of site engineer-in charge.

4

4475

17900

... More
Disconnection, dismantling of existing excitation panel for synchronous motor at LPG -1 substation, transportation of the same to Owner's warehouse/store within the plant premises for a distance of upto 2 km including all labour and materials, as per the job specifications, EIL standard specifications and as per directions of site engineer-in charge.

5

8950

44750

... More
Disconnection/Dismantling of existing CTs in existing 6.6KV switchboard including Installation, testing and commissioning of new indoor type switchboard mounted CTs with two cores: Core1: 150/1A (Class: 1, Burden: 15VA), Core 2: 150/5A (class: 5P10 Burden: 15VA). excluding supply of CTs, including supply of all mounting accessories, wiring material, terminal box, hook-up with terminal box, modifications if any required for mounting the same in existing switchboard including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge.

3

3491

10473

... More
Supply of indoor type switchboard mounted CTs with two cores: Core1: 150/1A (6.6kV, Class: 1, Burden: 15VA), Core 2: 150/5A (6.6kV, class: 5P10, Burden: 15VA) as per specification including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in- Charge

3

22984

68952

... More
Dismantling of existing cable trays( upto 750mm) and associated supports in substation, pipe-rack , cable- rack including transportation of same to owner's warehouse/assigned area within plant premises for a distance of 2km including all labour and material as per specifications/standard s of this tender and as per directions of Engineer-in-charge.

200

170

34000

... More
Disconnection and dismantling of existing HV cables for motors (power, control and space heater cables), including transportation of same to owner's warehouse/assigned area within plant premises for a distance of 2km including all labour , materials , as per specifications of this tender and as per directions of Engineer-in-Charge.

30

2238

67140

... More
Disconnection and dismantling of cables for MV motors (power, control and space heater cables), including transportation of same to owner's warehouse/assigned area within plant premises for a distance of 2km including including all labour and materials, as per specifications of this tender and as per directions of Engineer-in-Charge.

40

1790

71600

... More
Identification of already laid existing unused power & control cables inside cable cellar of LPG-I and LPG-2 substation and disconnection & removal of cables of different voltage grades and types up to a maximum OD of 40mm from existing trays / trenches / pipes supported on structure, based on their size (sq.mm) & voltage grade wise and transpiration of same to owner's store as per direction of engineer in charge.

200

36

7200

... More
Identification of already laid existing unused power & control cables inside cable cellar of LPG-I and LPG-2 substation and disconnection & removal of cables of different voltage grades and types above OD of 40mm from existing trays / trenches / pipes supported on structure, based on their size (sq.mm) & voltage grade wise and transpiration of same to owner's store as per direction of engineer in charge.

200

90

18000

... More
Disconnection, dismantling and removal of existing transformer including disconnection of HV and LV sides, NGR, associated bus ducts, de- compounding and cleaning of cable boxes etc., including transporting to owner's store, including all labour and materials, as per specifications of this tender and as per directions of Engineer-in-Charge .

-

-

-

... More
Existing transformer rated for 22 kV / 6.9 kV, 21000 kVA

2

42961

85922

... More
relocation of existing MCP

-

-

-

... More
Disconnection, dismantling, removal of existing field MCP (make : Siemens, model: MSM-K-WP), and subsequent relocation of the same including construction of new foundation (as required) for installation of existing MCP structural support upto distance of 50m (including disconnection, and re-routing of associated fire alarm cables and supply of fire alarm cables (2px1.5 sq.mm cable ) and junction boxes as required, re-connection of same complete in all respect ), as per scope of work/Job spec. document no. B650-000-16-50-SOW-3001 as per directions of Engineer in charge including all labour and materials, as per specifications of this tender.

5

2112

10560

... More
Relocation of field FCS

-

-

-

... More
Disconnection, dismantling, removal of existing field FCS (make : Neumann model: MDK Series) and loudspeakers, and subsequent relocation of the same including construction of new foundation (as required) for installation of existing FCS structural support upto distance of 50m (including disconnection, and re-routing of associated cables and supply of PA system cables (5p x0.9 mm dia cable ) and junction boxes (as required) ,re-connection of same complete in all respect), as per scope of work/Job spec. document no. B650-000-16-50-SOW-3001 as per directions of Engineer in charge including all labour and materials, as per specifications of this tender

5

130305

651525

... More
relocation of telephones

-

-

-

... More
Disconnection, dismantling, removal of existing field telephones (make : resistel), and subsequent relocation of the same including construction of new foundation (as required) for installation of existing telephones structural support upto distance of 50m (including disconnection, and re-routing of associated telephone cables and supply of telephone cables (2px0.9 mm dia jelly filled cable ) and junction boxes as required, re-connection of same complete in all respect), as per scope of work/Job spec. document no. B650-000-16-50- SOW-3001 as per directions of Engineer in charge including all labour and materials, as per specifications of this tender.

5

11188

55940

... More
TRANSFORMERS

-

-

-

... More
Installation of transformers of the following ratings excluding the construction of foundation, including transportation from store/yard to site at the place of installation, unpacking, positioning in place, site assembly of loosely furnished accessories, including connection of auxiliary circuits, topping up with oil and testing of oil with contractor's own test equipment, including fixing of nuts and bolts etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge.

-

-

-

... More
2 Winding ONAN/ONAF outdoor transformer with OLTC. 22 kV / 6.6 kV 21 MV·A

4

53701

214804

... More
Filtration of transformer oil by stream line filter machine provided by the contractor for improving the insulation strength of oil to the required strength, including all labour and materials, specifications of this tender and directions of Engineer-in-Charge. (Excluding the supply of oil).

-

-

-

... More
Filtration of transformer oil with dissolved gas analysis test.

3400

27

91800

... More
Filtration of transformer oil without dissolved gas analysis test.

34000

18

612000

... More
Supply of transformer oil conforming to IS-335 in non-returnable 220 litre drums for topping up various transformers. The oil shall be tested prior to filling up and improved by filtering, if required, including all labour and materials, specifications of this tender and directions of Engineer-in-Charge.

-

-

-

... More
No. of Drums.

4

20943

83772

... More
Testing and commissioning of transformers of the following rating including all labour and materials, as per specifications of this tender and directions of Engineer-in-Charge.

-

-

-

... More
2 Winding ONAN/ONAF outdoor transformer with OLTC. 22 kV / 6.9 kV 21 MV·A

4

53701

214804

... More
SWITCHBOARDS / UPS / VSD / BATTERY CHARGERS / PANELS

-

-

-

... More
Installation, testing and commissioning of switch-boards, relay and control panels, annunciation panels, UPS system, battery chargers, distribution boards, cubicles with electrical equipment, VSD panels, misc. electrical panels etc., including transportation from store/yard to site at the place of installation, unpacking, assembly, including mounting and wiring of loose parts supplied by equipment vendor, interconnection of shipping sections and requisite inter- panel wiring between shipping sections, including supply of all wiring materials, installation on foundations or fixing to wall or steel structures, aligning, levelling, grouting, testing and calibration of relays and meters etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge.

-

-

-

... More
Weight of the Unit upto 100 kg.

1

2685

2685

... More
Weight of the Unit from 101 upto 500 kg.

3

3133

9399

... More
Weight of the Unit from 501 upto 1000 kg.

2

4475

8950

... More
Weight of the Unit from 1001 upto 1500 kg.

4

5370

21480

... More
Weight of the Unit from 1501 upto 3000 kg.

2

11188

22376

... More
Weight of the Unit from 3001 upto 5000 kg.

1

15663

15663

... More
Supply of following indoor drawout type MV switchboard as per EIL specification No. 6-51-0018, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in- Charge.

-

-

-

... More
Drawout type MV switchboards. 415 V 800 A 50 kA for 1 second

1

2388938

2388938

... More
Installation, testing and commissioning of following drawout type MV switch boards, including transportation from store/yard to site at the place of installation, proper storage, assembly of sections, installation on concrete trenches/foundation, mounting and wiring of loose parts supplied by the equipment vendor, aligning, levelling, testing, calibration of meters/relays and all other accessories, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge.

-

-

-

... More
Drawout type MV switchboards. 415 V 800 A 50 kA for 1 second

1

238896

238896

... More
MISCELLANEOUS CONTROL GEAR

-

-

-

... More
Installation, testing and commissioning of miscellaneous surface mounted industrial/FLP control gear such as lighting/power panel, push button stations, motor starter, communication equipment, junction boxes, panels, plugs, sockets, including supply of necessary hardware, touch up painting including supply of paint, including transportation from store/yard to site at the place of installation, unpacking, (excluding fixing of cable glands and cable terminations), including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge.

-

-

-

... More
Weight of the unit up to 5 kg.

2

492

984

... More
Weight of the unit above 5 kg. but upto 20 kg.

60

895

53700

... More
Weight of the unit above 20 kg. but upto 100 kg.

2

1790

3580

... More
Supply of Industrial, weather proof type Push Button stations as per EIL specification No. 6-51-0014, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge.

-

-

-

... More
With stop (latching type) push button.

4

2327

9308

... More
Supply of flameproof and weather proof type Push Button station as per EIL standard specification No. 6-51-0006 as per approved drawings, specifications of this tender and directions of Engineer-in-Charge.

-

-

-

... More
With start, stop push buttons and one Three position selector switch and ammeter.

8

9935

79480

... More
PLUGS, SOCKETS AND JUNCTION BOXES

-

-

-

... More
Supply of weatherproof metal clad 415V, TPN, industrial type socket and plug with heavy duty interlocking switch, with adequately sized cable adaptor box for incoming and outgoing cable terminations, including supply of double compression brass nickel plated cable glands, tinned copper lugs, including all labours and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge.

-

-

-

... More
63 A, 415 V, 5 pin sockets along with associated 5 pin plugs.

4

19126

76504

... More
Supply of following types of FLP(II A/II B) and WP sockets, plugs and handlamps as per EIL specification No. 6-51-0021, including all labours and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge.

-

-

-

... More
63 A, 415 V, 5 pin socket.

6

16379

98274

... More
63 A, 415 V, 5 pin Plugs for item no. 01EE.1060.20.10

6

5728

34368

... More
32 A, 415 V, 4 pin socket.

2

14741

29482

... More
32 A, 415 V, 4 pin Plugs for item no. 01EE.1060.20.50

2

5155

10310

... More
240 V, 15 A, 3 pin socket.

45

4565

205425

... More
240 V, 15 A, 3 pin Plugs for item no. 01EE.1060.20.70

45

2685

120825

... More
Supply, installation, cable termination, connection, testing and commissioning of following types of FLP and WP junction boxes, as per EIL specification No. 6-51-0061, including all labours and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge.

-

-

-

... More
FLP (IIA/IIB) and WP DC JB with 15 A, 16 terminals suitable for 1 No. incoming and 6 Nos. outgoing cable entries complete with FLP cable glands for incoming and outgoing cables and 3 Nos. blocking plugs.

4

6892

27568

... More
FLP(II A/II B) and WP 4 way JB complete with 4 Nos. FLP cable glands and 2 Nos. blocking plug suitable for cables upto 3 x 2.5 sq. mm YWY / XWY cable.

130

14786

1922180

... More
Supply, installation, cable termination, connection, testing and commissioning of following types of FLP and WP junction boxes, suitable for gas group IIA/IIB, temperature class T3, as per EIL specification No. 6-51-0061, including suitably sized busbars with current rating equal to the largest cable current rating, glands, lugs, earthing terminals, canopy etc, including all labours and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge.

-

-

-

... More
Suitable for 415V system with 1 Run(s) of 3 core 95 mm² incoming cable(s) and 1 Run(s) of 3 core 50 mm² outgoing cable(s)

2

14266

28532

... More
Suitable for 415V system with 1 Run(s) of 3 core 95 mm² incoming cable(s) and 1 Run(s) of 3 core 16 mm² outgoing cable(s)

3

11877

35631

... More
Suitable for 415V system with 1 Run(s) of 3 core 35 mm² incoming cable(s) and 1 Run(s) of 3 core 16 mm² outgoing cable(s)

2

16558

33116

... More
Suitable for 415V system with 2 Run(s) of 3 core 185 mm² incoming cable(s) and 1 Run(s) of 3 core 95 mm² outgoing cable(s)

4

18795

75180

... More
Suitable for 415V system with 3 Run(s) of 3 core 300 mm² incoming cable(s) and 1 Run(s) of 3 core 240 mm² outgoing cable(s)

2

35800

71600

... More
Suitable for 415V system with 2 Run(s) of 3 core 240 mm² incoming cable(s) and 1 Run(s) of 3 core 185 mm² outgoing cable(s)

2

26850

53700

... More
NEUTRAL GROUNDING RESISTOR

-

-

-

... More
Installation, testing and commissioning of outdoor type following neutral grounding resistor consisting of cast iron/stainless steel grid resistor with/without neutral CT including connection of one end of resistor with transformer neutral and the other end of the resistor to the earthing grid, including transportation from store/yard to site at the place of installation, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge.

-

-

-

... More
NGR rated for 6.6 kV 600 A

4

18912

75648

... More
CANOPIES

-

-

-

... More
Supply, fabrication and installation of FRP canopies for outdoor electrical miscellaneous equipments such as lighting/power panels and distribution junction boxes, local panels , PB stations etc. to render them weather proof including supply of necessary hardware for fixing and clamping with the equipment, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge.

-

-

-

... More
Lighting Panel/Power panel/distribution junctions boxes.

15

2864

42960

... More
Manual call points/field call stations.

6

2864

17184

... More
Push button stations.

12

2864

34368

... More
FLP receptacles.

6

2864

17184

... More
ANCHOR FASTENERS

-

-

-

... More
Supply, drilling in RCC and fixing of metallic anchor fasteners for supporting of cable trays and miscellaneous electrical switchgear of following sizes, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge.

-

-

-

... More
3/16" BSW.

10

72

720

... More
5/16" BSW.

10

81

810

... More
1/4" BSW.

10

81

810

... More
3/8" BSW.

10

107

1070

... More
5/8" BSW.

10

134

1340

... More
1/2" BSW.

10

125

1250

... More
TESTING AND COMMISSIONING OF MOTORS

-

-

-

... More
Testing and commissioning of MV motors of following ratings and checking of all interface connections, change of grease, wherever required, including supply of approved type of grease, no load/full load running of motor, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge.

-

-

-

... More
Upto 5.5 kW.

10

1343

13430

... More
Above 5.5 kW but upto 11 kW.

5

1790

8950

... More
Above 11 kW but upto 22 kW.

5

2685

13425

... More
Above 22 kW but upto 45 kW.

5

3133

15665

... More
Above 45 kW but upto 75 kW.

2

4923

9846

... More
Above 75 kW but upto 125 kW.

2

6713

13426

... More
Above 125 kW but upto 160 kW.

1

8503

8503

... More
Testing and commissioning of HV motors of following ratings and checking of all interface connections, change of grease in bearings, wherever required, including supply of approved type of grease, no load/full load running of motor, including all labour and materials, as per specifications of this tender and directions of Engineer-in-Charge.

-

-

-

... More
Above 400 kW but upto 800 kW.

2

12530

25060

... More
Above 800 kW but upto 1200 kW.

6

15663

93978

... More
Above 1200 kW but upto 2000 kW.

3

22375

67125

... More
Above 2000 kW but upto 3000 kW.

1

23718

23718

... More
Testing and commissioning of safe area/ FLP motor operated valve actuators with integral starter of different sizes, checking of all interface connections, local/remote controls, settings of limit and torque switches, no load/full load running, including all labour and materials, as per specifications of this tender and directions of Engineer-in-Charge.

-

-

-

... More
Safe area/FLP motor operated valve actuators.

10

2685

26850

... More
Testing and commissioning of 415V, TPN, Lube Oil Heaters of following ratings, checking of all interface connections, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in- Charge

-

-

-

... More
Upto 5.5 kW

2

1566

3132

... More
Above 5.5 kW and upto 11 kW

2

1960

3920

... More
Above 11 kW and upto 22kW

2

2936

5872

... More
DISMANTLING AND DISCONNECTION OF ELECTRICAL EQUIPMENTS.

-

-

-

... More
Disconnection of following existing motors (power, control and space heater cables), including all labour and materials, as per specifications of this tender and as per directions of Engineer-in-Charge.

-

-

-

... More
Existing MV motors.

20

1343

26860

... More
Existing HV motors.

10

1790

17900

... More
Disconnection of power, control and space heater cables from existing switchboards/panels/misc. electrical equipment, including all labour and materials, as per specifications of this tender and as per directions of Engineer- in-Charge.

-

-

-

... More
disconnection and dismantling of Cables from existing switchboards/panels/misc. electrical equipment.

50

2238

111900

... More
Cables from existing switchboards/panels/misc. electrical equipment.

50

2238

111900

... More
SAFETY EQUIPMENT

-

-

-

... More
Supply and installation of the following, including the supply of necessary clamps, bolts, rawl plugs etc., breaking and making good of walls, if required, mounting, including all labour and materials, complete and as per applicable standards and CEA Guidelines and as per directions of Engineer-in-Charge.

-

-

-

... More
Shock hazard charts complete with frame and glass.

2

1208

2416

... More
First Aid Boxes.

2

1611

3222

... More
6.8 kg capacity CO2 type fire extinguishers.

2

9666

19332

... More
Sand buckets with stand (Each with at least 3 sand buckets).

2

2819

5638

... More
Supply and laying of 900 mm wide safety insulation mats complying to IS-15652, of following grades required for maintenance of electrical equipment in substation, including cutting to required shape in running length, including all labour and materials, as per applicable Indian or International standards and CEA Guidelines and as per directions of Engineer-in-Charge.

-

-

-

... More
3.3 kV grade.

20

2014

40280

... More
33 kV grade.

10

2819

28190

... More
Supply of following items as per applicable Indian standards/CEA Guidelines.

-

-

-

... More
Rubber hand gloves (11 kV grade).

2

761

1522

... More
Enamelled caution boards.

5

385

1925

... More
Discharge rod with earthing facility (upto 11 kV grade).

2

1906

3812

... More
HV fuse puller handle.

2

644

1288

... More
SUPPLY OF SPARES / LAMPS

-

-

-

... More
MV HRC Fuses

-

-

-

2

90

180

2

125

250

2

179

358

... More
100 A.

2

313

626

... More
160 A.

2

510

1020

... More
250 A.

2

609

1218

... More
315 A.

2

644

1288

... More
400 A.

2

725

1450

... More
CCOE APPROVAL

-

-

-

... More
Obtaining approval from CCoE(Chief Controller of Explosives)for imported equipment such as motors, local control panels, junction boxes & misc. equipment, etc. based on the type test certificates made available from the equipment/sub vendor supplier including submission of application to statutory authorities, necessary fee, all test certificates, equipment drawings in required volume, interaction with the authority, perusal of approval and obtaining necessary approval certificate before the energisation of equipment as per specification of this tender and direction of Engineer in charge.

1

134252

134252

... More
SUPPLY OF MV CABLES

-

-

-

... More
Supply of 1100 V grade, Copper Conductor,XLPE insulated and armoured, cables of following sizes as per EIL standard specification No. 6-51-0051, data sheets, specifications of this tender and directions of Engineer-in-Charge.

-

-

-

... More
2 C x 16 sq. mm

400

313

125200

... More
3 C x 2.5 sq. mm

12000

107

1284000

... More
3 C x 4 sq. mm

8810

143

1259830

... More
4 C x 10 sq. mm

2680

412

1104160

... More
3 C x 16 sq. mm

2800

443

1240400

... More
Supply of 1100 V grade, Aluminium Conductor, XLPE insulated and armoured, cables of following sizes as per EIL standard specification No. 6-51-0051, data sheets, specifications of this tender and directions of Engineer-in-Charge.

-

-

-

... More
3.5 C x 25 sq. mm

3000

152

456000

... More
2 C x 35 sq. mm

710

116

82360

... More
3 C x 35 sq. mm

1500

161

241500

... More
3.5 C x 35 sq. mm

450

188

84600

... More
2 C x 50 sq. mm

400

143

57200

... More
3 C x 50 sq. mm

50

197

9850

... More
3.5 C x 50 sq. mm

1340

224

300160

... More
2 C x 70 sq. mm

2130

190

404700

... More
3 C x 70 sq. mm

950

286

271700

... More
3.5 C x 70 sq. mm

3860

295

1138700

... More
2 C x 95 sq. mm

3800

242

919600

... More
3 C x 95 sq. mm

2700

331

893700

... More
3.5 C x 95 sq. mm

3440

376

1293440

... More
3.5 C x 120 sq. mm

1500

492

738000

... More
3 C x 185 sq. mm

4790

662

3170980

... More
3 C x 240 sq. mm

2200

823

1810600

... More
3 C x 300 sq. mm

2880

1036

2983680

... More
3.5 C x 300 sq. mm

300

1169

350700

... More
Supply of 1100 V grade, Copper Conductor, Individual pair shielded & Overall shielded, twisted pair/triad, XLPE insulated, Armored, FRLS outer-sheathed cables of following sizes as per EIL standard specification No. 6-51-0052, data sheets, specifications of this tender and directions of Engineer-in-Charge.

-

-

-

... More
2 Pair x 2.5 sq. mm

5650

179

1011350

... More
4 Pair x 2.5 sq. mm

40660

286

11628760

... More
6 Pair x 2.5 sq. mm

12060

394

4751640

... More
12 Pair x 2.5 sq. mm

2056

725

1490600

... More
SUPPLY OF HV CABLES (MULTI CORE)

-

-

-

... More
Supply of 6.6 kV (UE) grade, Al/Cu Conductor, XLPE insulated and armoured cables of following sizes as per EIL standard specification No. 6-51-0051, data sheets, specifications of this tender and directions of Engineer-in-Charge.

-

-

-

... More
3 C x 240 sq. mm, Al

6500

1181

7676500

... More
LAYING OF CABLES

-

-

-

... More
Laying of cables of different voltage grade and types of the following overall diameters in ready trays/trenches/ supported on structure/pull through pipes including supply and fixing of stainless steel strip number tags, supply and applying of fireproofing paint to meet OISD requirement (for 1m length near terminations), supply and fixing of GI saddles & saddle bars, trefoil clamps (for single core cables) etc., including transportation from store/yard to site at the place of installation, unpacking, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in- Charge

-

-

-

... More
Cables with OD upto 20 mm.

27400

18

493200

... More
Cables with OD above 20 mm but upto 30 mm.

12000

27

324000

... More
Cables with OD above 30 mm but upto 40 mm.

4500

36

162000

... More
Cables with OD above 40 mm but upto 50 mm.

14290

45

643050

... More
Cables with OD above 50 mm but upto 60 mm.

4680

63

294840

... More
Cables with OD above 60 mm but upto 80 mm.

100

81

8100

... More
Laying of cables (using cable pulling by motorized winch with torque limits) of different voltage grade and types of the following overall diameters in ready trays/trenches/supported on structure/pull through pipes including supply and fixing of stainless steel strip number tags, supply and fixing of GI saddles & saddle bars, trefoil clamps (for single core cables) etc., including transportation from store/yard to site at the place of installation, unpacking, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge

-

-

-

... More
Cables with OD above 60 mm but upto 80 mm.

6500

81

526500

... More
END TERMINATIONS

-

-

-

... More
Supply of Unearthed grade H.V. termination kits of (indoor/outdoor type) as per EIL standard specification No. 6-51-0051, excluding cable glands and lugs, as per approved drawings and as per specifications of this tender and directions of Engineer-in-Charge.

-

-

-

... More
3 Core cable Indoor termination kit for 6.6 kV 240 mm²

12

7232

86784

... More
3 Core cable Outdoor termination kit for 6.6 kV 240 mm²

12

7608

91296

... More
Termination of Unearthed grade HV cables and connection of leads including fixing of cable glands, supply and fixing of PVC shrouds for outdoor terminations, cutting and stripping of cable insulation, crimping the lug onto the conductor, restoration of the insulation, clamping of cable cores and earthing of armour, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. (Excluding supply of termination kits and cable glands).

-

-

-

... More
3 Core cable termination kit for 6.6 kV 240 mm²

24

5370

128880

... More
Termination of XLPE insulated armoured power cables (up to 1100 V grade) and connection of leads excluding the supply of cable glands and lugs but including fixing of cable glands, supply and fixing of PVC shrouds for outdoor terminations, cutting and stripping of cable insulation, crimping the lug on to the conductor, clamping of the cable-cores, marking with wire number, ferrules etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge.

-

-

-

... More
Cables with OD upto 20 mm.

200

179

35800

... More
Cables with OD above 20 mm but upto 30 mm.

150

260

39000

... More
Cables with OD above 30 mm but upto 40 mm.

100

322

32200

... More
Cables with OD above 40 mm but upto 50 mm.

40

448

17920

... More
Cables with OD above 50 mm but upto 60 mm.

20

582

11640

... More
Cables with OD above 60 mm but upto 80 mm.

10

895

8950

... More
Termination of communication, fire alarm & control paired cables and connection of leads excluding the supply of cable glands and lugs but including fixing of cable glands, supply and fixing of PVC shrouds for outdoor terminations, cutting, stripping of cable insulation, crimping the lug on to the conductor, clamping of the cable- cores, marking with wire number, ferrules etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge.

-

-

-

... More
All sizes from 1P to 4P and upto 2.5 sq. mm

350

224

78400

... More
All sizes from 5P to 10P and upto 2.5 sq. mm

100

269

26900

... More
All sizes from 11P to 15P and upto 2.5 sq. mm

50

358

17900

... More
Fire proofing of cables including supply of all fire proofing paint, including all labour and materials, as per IEC-60331, specifications of this tender and directions of Engineer-in- Charge. (Actual area of surface painted shall be measured).

50

1128

56400

... More
STRAIGHT THROUGH JOINTS

-

-

-

... More
Supply and Making of heat shrinkable type straight through joints for 1100 volt grade power cables as per EIL standard specification No. 6-51-0051, including cutting, stripping of cable insulation complete with supply of compression / crimping type ferrules, plastic mould and epoxy resin compound etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge.

-

-

-

... More
Cables with OD upto 20 mm.

30

1853

55590

... More
Cables with OD above 20 mm but upto 30 mm.

10

2819

28190

... More
Cables with OD above 30 mm but upto 40 mm.

10

4028

40280

... More
Cables with OD above 40 mm but upto 50 mm.

5

5800

29000

... More
Cables with OD above 50 mm but upto 60 mm.

5

7250

36250

... More
Supply and Making of heat shrinkable type straight through joints for communication, fire alarm & control paired cables, including cutting, stripping of cable insulation complete with supply of compression / crimping type ferrules, plastic mould and epoxy resin compound etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge.

-

-

-

... More
All sizes from 2 to 7 cores and upto 2.5 sq. mm.

10

1790

17900

... More
G.I. & PVC PIPES

-

-

-

... More
Supply and laying of following sizes of G.I. Pipes (medium) in required length fixed on steel, concrete or similar structure, laid in trenches, ready to be buried in concrete including cutting, threading, bending and similar works, supply of clamps, small iron structures, spacers and installation of seats, plugs, bushings etc., small civil works, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in- Charge.

-

-

-

... More
50 mm NB.

370

609

225330

... More
100 mm NB.

650

1513

983450

... More
150 mm NB.

350

2273

795550

... More
Supply and laying of following sizes of PVC Pipes in required length fixed on steel, concrete or similar structure, laid in trenches, ready to be buried in concrete including cutting, threading, supply of bends and similar works, supply of clamps, small iron structures, spacers and installation of seats, plugs, bushings etc., small civil works, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer- in-Charge.

-

-

-

... More
50 mm NB.

30

197

5910

... More
100 mm NB.

30

716

21480

... More
150 mm NB.

30

1486

44580

... More
STRUCTURAL STEEL

-

-

-

... More
Supply, fabrication, galvanising and installation of base frames, supports for switchgear, and brackets for miscellaneous electrical equipments, cable and cable tray supports out of rolled MS sections, pipes, plates etc. including welding, bolting, rivetting, supply of necessary anchor bolts and grouting etc., including breaking walls, floors etc. for structures as required including supply of all GI hardware materials, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in- Charge. (Any item weighing up to 1 kg. or less shall neither be measured nor paid).

5500

98

539000

... More
Supply and installation of push button station supports complete with base plate, foundations bolts, grouting and painting(as per Table-10 of specification 6-79-0020 suitable for highly corrosive environment) etc., including all labour and materials, as per approved drawings and directions of Engineer-in- Charge.

-

-

-

... More
As per std. 7-51-0306

50

2417

120850

... More
As per std. 7-51-0307

20

2417

48340

... More
CABLE - TRAYS

-

-

-

... More
Supply and installation of prefabricated ladder type Fibre reinforced plastic(FRP) cable trays of approved make with a rung and cable tray fittings similar to trays as per std.7-51-0333, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in- charge

-

-

-

... More
300 mm wide Straight run cable tray.

300

1011

303300

... More
600 mm wide Straight run cable tray.

150

1047

157050

... More
750 mm wide Straight run cable tray.

2500

1468

3670000

... More
Horizontal bends for 300 mm wide tray with 1000 mm bending radius.

5

3526

17630

... More
Horizontal bends for 600 mm wide tray with 1000 mm bending radius.

6

3222

19332

... More
Horizontal bends for 750 mm wide tray with 1000 mm bending radius.

50

4538

226900

... More
Vertical outside bends for 300 mm wide tray with 1000 mm bending radius.

3

3526

10578

... More
Vertical outside bends for 600 mm wide tray with 1000 mm bending radius.

6

3222

19332

... More
Vertical outside bends for 750 mm wide tray with 1000 mm bending radius.

40

4538

181520

... More
Vertical inside bends for 300 mm wide tray with 1000 mm bending radius.

3

3526

10578

... More
Vertical inside bends for 600 mm wide tray with 1000 mm bending radius.

6

3061

18366

... More
Vertical inside bends for 750 mm wide tray with 1000 mm bending radius.

40

4430

177200

... More
Tee Joints for 300 mm wide tray with 1000 mm bending radius.

2

3222

6444

... More
Tee Joints for 600 mm wide tray with 1000 mm bending radius.

2

3508

7016

... More
Tee Joints for 750 mm wide tray with 1000 mm bending radius.

20

3625

72500

... More
Reducers 750 - 300 RHS

2

2658

5316

... More
Reducers 750 - 300 LHS

2

3329

6658

... More
Reducers 600 - 300 RHS

2

2417

4834

... More
Reducers 600 - 300 LHS

2

2417

4834

... More
Reducers 750 - 600 RHS

2

2819

5638

... More
Reducers 750 - 600 LHS

2

2819

5638

... More
Supply and installation of following prefabricated slotted type FRP cable trays of approved make with a rung and cable tray fittings including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-charge

-

-

-

... More
60 mm wide.

3000

251

753000

... More
100 mm wide.

1100

510

561000

... More
150 mm wide.

500

644

322000

... More
Supply and Installation of FRP covers for cable trays meeting all material requirements, including all labour and materials as per approved drawings, specifications of this tender and directions of Engineer-in-charge

470

1208

567760

... More
CABLE GLANDS

-

-

-

... More
Supply of nickel-plated, flame proof IIA/IIB double compression type brass cable glands, suitable for out door terminations of armoured PVC cables of following overall diameter (excluding termination and connection of cables), including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge.

-

-

-

... More
Cables with OD upto 20 mm.

50

340

17000

... More
Cables with OD above 20 mm but upto 30 mm.

50

600

30000

... More
Cables with OD above 30 mm but upto 40 mm.

40

761

30440

... More
Cables with OD above 40 mm but upto 50 mm.

20

1334

26680

... More
Cables with OD above 50 mm but upto 60 mm.

10

1522

15220

... More
Cables with OD above 60 mm but upto 80 mm.

10

2059

20590

... More
Supply of nickel plated brass single compression cable glands of following overall diameter (excluding termination and connections of cables), including drilling of suitable holes in equipments for fixing purposes etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge.

-

-

-

... More
Cables with OD upto 20 mm.

50

125

6250

... More
Cables with OD above 20 mm but upto 30 mm.

50

206

10300

... More
Cables with OD above 30 mm but upto 40 mm.

40

385

15400

... More
Cables with OD above 40 mm but upto 50 mm.

20

421

8420

... More
Cables with OD above 50 mm but upto 60 mm.

10

573

5730

... More
Cables with OD above 60 mm but upto 80 mm.

10

913

9130

... More
Supply and fixing of FLP(IIA/IIB) blocking plugs for blocking unused cable entries with following diameter in outdoor electrical equipment including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge.

-

-

-

... More
Cables with OD up to 20 mm

20

260

5200

... More
Cables with OD above 20 mm but upto 30 mm

20

367

7340

... More
Cables with OD above 30 mm but upto 40 mm

20

483

9660

... More
Cables with OD above 40 mm but upto 50 mm

10

662

6620

... More
Cables with OD above 50 mm but upto 60 mm

10

806

8060

... More
Cables with OD above 60 mm but upto 80 mm

10

1047

10470

... More
MARKERS

-

-

-

... More
Supply and installation of cable markers as per std. 7-51-0301, for underground cable runs with 14 SWG enamelled steel plate with white lettering on jade green background inclusive of providing and fixing supports, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge.

100

1208

120800

... More
Supply and installation of earth pit markers for directly buried GI pipe electrodes as per std. 7-51-0101 with 14 SWG enamelled steel plate engraved with white letters BURIED, EARTH ELECTRODE on JADE green background complete with support and foundation, including all labour and materials, as per approved drawings, specifications of this tender and direction of Engineer- in-Charge.

50

1208

60400

... More
CABLE LUGS

-

-

-

... More
Supply of crimping type long barrel tinned copper lugs with circular/sector shaped barrel for following conductor sizes, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge.

-

-

-

... More
All sizes upto 10 sq. mm

30

18

540

... More
All sizes from 16 to 35 sq. mm

30

27

810

... More
All sizes from 50 to 185 sq. mm

20

188

3760

... More
All sizes from 240 to 400 sq. mm

20

385

7700

... More
Supply of crimping type long barrel aluminium lugs with circular/sector shaped barrel for following conductor sizes, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge.

-

-

-

... More
All sizes upto 10 sq. mm

30

18

540

... More
All sizes from 16 to 35 sq. mm

30

18

540

... More
All sizes from 50 to 185 sq. mm

20

107

2140

... More
All sizes from 240 to 400 sq. mm

10

143

1430

... More
Supply of crimping type long barrel Bimetallic lugs with Al barrel & tinned Cu palm with circular/sector shaped barrel for following conductor sizes, as per approved drawings, specifications of this tender and directions of Engineer-in- Charge.

-

-

-

... More
All sizes upto 10 sq. mm

30

18

540

... More
All sizes from 16 to 35 sq. mm

20

27

540

... More
All sizes from 50 to 185 sq. mm

30

206

6180

... More
All sizes from 240 to 400 sq. mm

10

412

4120

... More
Supply of crimping type long barrel Bimetallic lugs with tinned Cu barrel & Al palm with circular/sector shaped barrel for following conductor sizes, as per approved drawings, specifications of this tender and directions of Engineer-in- Charge.

-

-

-

... More
All sizes upto 10 sq. mm

30

18

540

... More
All sizes from 16 to 35 sq. mm

30

45

1350

... More
All sizes from 50 to 185 sq. mm

10

107

1070

... More
All sizes from 240 to 400 sq. mm

10

143

1430

... More
INTERFACE BOX

-

-

-

... More
Supply, installation, testing and commissioning of interface box made out of 2.03 mm (14 gauge) sheet steel, with one anti-rust coat of primer, with two finished coats of approved epoxy paint, with following No. of Clamp type terminals suitable for 2.5 sq. mm copper conductor with hinged lockable door, detachable gland plate at the bottom/top complete with termination and connections of incoming/ outgoing cables, including all labour and materials, as per specifications of this tender and directions of Engineer-in-Charge.

-

-

-

... More
With 400 Terminals with overall dimensions 1250 x 1250 x 500 mm.

1

45109

45109

... More
FIRE PROOFING OF CABLES

-

-

-

... More
Fire proofing of cables including supply of all fire proofing paint, including all labour and materials, as per specifications of this tender and directions of Engineer-in-Charge. (Actual area of surface painted shall be measured).

30

1128

33840

... More
ADAPTORS / REDUCERS / NIPPLES ETC.

-

-

-

... More
Supply and fixing nickel-plated brass adaptors/ reducers for cable glands of following sizes including all labour and materials complete as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. Adaptors shall have male part threaded as per Eqpt. threads and the other end to receive glands having E.T. thread.

-

-

-

... More
Eqpt. Thread 3/4" PF (J.I.S.)-E.T. Thread 3/4"ET

5

403

2015

... More
Eqpt. Thread 1" PF (J.I.S.) - E.T. Thread 3/4"ET

5

403

2015

... More
Eqpt. Thread 1" PF (J.I.S.) -E.T. Thread 1"ET

5

528

2640

... More
Eqpt. Thread 1-1/2" PF (J.I.S.)- E.T. Thread 1-1/4"ET

2

609

1218

... More
Eqpt. Thread 1-1/2" PF (J.I.S.)- E.T. Thread 1-1/2"ET

2

689

1378

... More
Eqpt. Thread 2" PF (J.I.S.) -E.T. Thread 1-1/2"ET

2

1011

2022

... More
Supply and installation of GI reducers/enlargers of following sizes for cable glands of following sizes including all labour and materials complete as per approved drawings, specifications of this tender and directions of Engineer-in- Charge. Adaptors shall have male part threaded as per Eqpt. threads and the other end to receive glands having E.T. thread.

-

-

-

... More
Eqpt. Thread PG 13.5(DIN) - E.T. Thread 3/4" ET

2

519

1038

... More
Eqpt. Thread PG 16 (DIN) -E.T. Thread 3/4" ET

2

635

1270

... More
Eqpt. Thread PG 21 (DIN) -E.T. Thread 1"ET

2

635

1270

... More
Eqpt. Thread PG 29 (DIN) -E.T. Thread 1-1/2" ET

2

707

1414

... More
Eqpt. Thread 1" ET (IS) -E.T. Thread 3/4" ET

2

367

734

... More
Eqpt. Thread 1-1/2" ET (IS) -E.T. Thread 1" ET

2

528

1056

... More
Eqpt. Thread 1-1/2" ET (IS) -E.T. Thread 1-1/2" ET

2

564

1128

... More
Eqpt. Thread 2" ET (IS) -E.T. Thread 1-1/2" ET

2

806

1612

... More
Supply and fixing FLP(IIA/IIB), weatherproof, nickel-plated brass adaptors/reducers for cable glands of following sizes including all labour and materials complete as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. Adaptors shall have male part threaded as per Eqpt. threads and the other end to receive glands having E.T. thread.

-

-

-

... More
Eqpt. Thread 3/4" PF (J.I.S.)-E.T. Thread 3/4"ET

2

528

1056

... More
Eqpt. Thread 1" PF (J.I.S.) -E.T. Thread 3/4"ET

2

644

1288

... More
Eqpt. Thread 1" PF (J.I.S.) -E.T. Thread 1"ET

2

644

1288

... More
Eqpt. Thread 1-1/2" PF (J.I.S.)- E.T. Thread 1-1/4"ET

2

967

1934

... More
Eqpt. Thread 1-1/2" PF (J.I.S.)- E.T. Thread 1-1/2"ET

2

1047

2094

... More
Eqpt. Thread 2" PF (J.I.S.) -E.T. Thread 1-1/2"ET

2

1172

2344

... More
Supply and installation of FLP(IIA/IIB) GI reducers/ enlargers of following sizes for cable glands of following sizes including all labour and materials complete as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. Adaptors shall have male part threaded as per Eqpt. threads and the other end to receive glands having E.T. thread.

-

-

-

... More
Eqpt. Thread PG 13.5(DIN) - E.T. Thread 3/4" ET

2

519

1038

... More
Eqpt. Thread PG 16 (DIN) -E.T. Thread 3/4" ET

2

635

1270

... More
Eqpt. Thread PG 21 (DIN) -E.T. Thread 1"ET

2

635

1270

... More
Eqpt. Thread PG 29 (DIN) -E.T. Thread 1-1/2" ET

2

1155

2310

... More
Eqpt. Thread 1" ET (IS) -E.T. Thread 3/4" ET

2

609

1218

... More
Eqpt. Thread 1-1/2" ET (IS) -E.T. Thread 1" ET

2

770

1540

... More
Eqpt. Thread 1-1/2" ET (IS) -E.T. Thread 1-1/2" ET

2

850

1700

... More
Eqpt. Thread 2" ET (IS) -E.T. Thread 1-1/2" ET

2

1011

2022

... More
Supply and fixing of 100 mm, 1/2" GI nipples with 1/2" conduit threaded on one side and ¿" NPT on the other side to solenoid valve and in explosion proof terminal box including drawing of cable through the same, all labour and materials complete as per approved drawings, specifications of this tender and directions of Engineer-in-Charge.

2

806

1612

... More
LIGHTING POLES

-

-

-

... More
Supply and installation of Lighting Poles for floor mounting as per std. 7-51-0201, including all civil works, excavation, foundation, disposal of surplus earth, providing shoring, strutting and dewatering if required and including supply of cement, steel, GI pipes, base plates, paint and all sundry materials as required, including painting, (excluding supply and installation of control gear box/junction box), but including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge.

-

-

-

... More
Lighting poles for hazardous areas.

25

15707

392675

... More
Supply and installation of platform Lighting pole as per std. 7-51-0202, including all welding, structural works, paint and all sundry materials as required, including painting, (excluding supply and installation of control gear box/junction box), but including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge.

-

-

-

... More
Lighting poles for hazardous areas.

20

6041

120820

... More
Supply and installation of Flood Light Pole (two) as per std. 7-51-0205 (sheet 2 of 2) (excluding the supply and installation of control gear box/ junction boxes), including all civil works, excavation, foundation, disposal of surplus earth, providing shoring, strutting and dewatering if required and including supply of cement, steel, GI pipes, base plates, paint and all sundry materials as required, including painting, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in- Charge.

-

-

-

... More
Flood light poles for hazardous areas.

2

32220

64440

... More
HAZARDOUS AREA LIGHTING FIXTURES AND ACCESSORIES

-

-

-

... More
Installation, connection, testing and commissioning of following types of flame proof/Div.2 lighting fixtures and accessories, including cable termination and connection, fixing of cable glands, lugs, including supply of necessary hardwares, including transportation from store/yard to site at the place of installation, unpacking, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge.

-

-

-

... More
Well glass type pole mounting type for Ground Level.

30

448

13440

... More
Well glass type pole mounting type for Platform.

20

448

8960

... More
Well glass type bracket mounted.

195

448

87360

... More
Well glass type ceiling mounted.

250

448

112000

... More
3-way, junction box.

10

358

3580

... More
4-way, junction box.

130

448

58240

... More
FLP double obstruction aviation fixture.

2

2685

5370

... More
Supply of following FLP/Div.2 lighting fixtures complete with lamps, requisite FLP cable glands, plugs and necessary control gear as per EIL standard specification No. 6-51-0061, data sheet for lighting fixture schedule, including all albour and materials, specifications of this tender and directions of Engineer in-Charge.

-

-

-

... More
Type LED DC IIA/IIB Fixtures.

20

3732

74640

... More
Type LED FLP-5a fixtures.

60

8359

501540

... More
Type LED FLP-5b fixtures.

110

5844

642840

... More
Type FLP-LED-4 Fixtures.

240

7357

1765680

... More
Type FLP-LED-7 Fixtures.

55

7357

404635

... More
Type FLP-LED-9 Fixtures.

10

7966

79660

... More
Type FLP-LED-12 Fixtures.

2

8306

16612

... More
Supply and installation of Type-`A' clamps(for bracket mounted lighting fixtures) including bolt (MOC SS304) for fixing the fixture to the clamp as per EIL std.no.7-51-0221, including supply and fixing of anchor fasteners, nuts and bolts, washers etc. as per approved drawings, specifications of this tender and directions of Engineer-in-Charge.

215

689

148135

... More
Supply and installation of Type-`B' clamps(for ceiling mounted lighting fixtures) including bolt (MOC SS304) for fixing the fixture to the clamps per EIL std.no.7-51-0221, including supply and fixing of anchor fastners,nuts and bolts,washers as per approved drawings, specifications of this tender and directions of Engineer-in-Charge.

255

689

175695

... More
Supply and installation of adapters for Platform and ground pole mounted lighting fixtures as per EIL std.no.7-51-0221, approved drawings, specifications of this tender and directions of Engineer-in-Charge.

50

465

23250

... More
LIGHTING / POWER PANELS AND DISTRIBUTION BOARDS

-

-

-

... More
Supply, installation, connection, testing and commissioning of flame proof weather proof lighting/power panels (for gas group IIA/IIB) as per EIL std. spec. 6-51-0008, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge.

-

-

-

... More
40 A, 4 pole incomer MCB isolator and 6 Nos. outgoing double pole MCBs (upto 20 A).

1

55983

55983

... More
40 A, 4 pole incomer MCB isolator and 12 Nos. outgoing double pole MCBs (upto 20 A).

1

60413

60413

... More
40 A, 4 pole incomer MCB isolator and ELCB and 6 Nos. outgoing double pole MCBs (upto 20 A).

8

60816

486528

... More
40 A, 4 pole incomer MCB isolator and ELCB and 12 Nos. outgoing double pole MCBs (upto 20 A).

10

70079

700790

... More
Supply, installation, connection, testing and commissioning of safe area lighting/power panels, surface/flush mounting type, wall mounting type in dust tight (with hinged cover) sheet steel enclosure having 4 pole incomer and single pole MCB (9 kA type) for outgoing circuit control with complete wiring, including cable termination, connection and fixing of cable glands, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge.

-

-

-

... More
40 A, 4 pole incomer MCB isolator and ELCB and 12 Nos. outgoing single pole MCBs (upto 20 A).

1

22957

22957

... More
WIRING

-

-

-

... More
Circuit wiring in hazardous areas using (sizes given below) copper conductor, XLPE insulated, FRLS outer sleeve armoured cables (third core for earthing) from lighting/power panel/distribution junction box onwards, excluding the supply of cables, junction boxes and cable glands but including fixing of cable glands, supply and fixing of clamps, cable terminations and connections, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge.

-

-

-

... More
3 C x 2.5 sq. mm

12000

45

540000

... More
SOIL RESISTIVITY

-

-

-

... More
Measurement of soil resistivity in accordance with IS:3043, including all labour and materials, as per approved drawings, specifications of this tender and at locations as per directions of Engineer-in-Charge.

1

7608

7608

... More
EARTH ELECTRODES

-

-

-

... More
Supply, Installation, Testing and Commissioning of maintenance free Chemical earth electrode complete with earth pit and all necessary materials including excavation of earth pit, filling with maintenance free chemical for ease of operation and maintenance, back filling, providing necessary brick work, connections, including all labour and materials as per approved drawings, specifications of this tender and directions of engineer-in-charge

60

19422

1165320

... More
EARTH STRIPS

-

-

-

... More
Supply, installation and connection of following GI earthing strip along the cable trenches or cable trays or fixing to walls or structures including welding at joints, providing anti-corrosive paint or bitumen and jute covering for welded portion, clamping and necessary hardware for connecting, etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge.

-

-

-

... More
75 x 10 mm

50

609

30450

... More
50 x 6 mm

2000

358

716000

... More
40 x 5 mm

50

206

10300

... More
25 x 3 mm

1500

161

241500

... More
Supply, installation and connection of following GI earthing strip buried individually at a depth of 500 mm including welding at joints, providing anti- corrosive paint or bitumen and jute covering for welded portion, clamping and necessary hardware for connecting, excavation and refilling etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge.

-

-

-

... More
75 x 10 mm

50

627

31350

... More
50 x 6 mm

100

412

41200

... More
25 x 3 mm

50

233

11650

... More
EARTHING CONNECTION

-

-

-

... More
Connecting individual equipment to the earth strip or earth plate with following sizes of G.I. wire / G.I. wire rope including the supply of G.I. wire /G.I. wire rope, lugs, conductors, connecting to the G.I. strip or earth plate and necessary hardware for connection, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in- Charge.

-

-

-

... More
3/8" dia (10 mm) flexible rope.

150

134

20100

... More
5/8" dia (16 mm) flexible rope.

120

206

24720

... More
8 SWG GI Wire.

100

27

2700

... More
Supply and installation of 5 m long, 25 sq. mm (168/0.01772") insulated single core copper flexible conductor with crimped type lug at one end and approved crocodile clip at other end, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge.

-

-

-

... More
5 m long, 25 sq. mm (168/0.01772") insulated single core Cu flexible conductor.

5

2014

10070

... More
Supply and installation of 25 sq. mm (168/0.01772") copper flexibles of following length with copper lugs crimped on both sides for earthing of pipeline vessels, equipments (non electrical) as per std. 7- 51-0112, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge.

-

-

-

... More
300 mm

40

448

17920

... More
500 mm

40

528

21120

... More
1500 mm

20

967

19340

... More
EARTH PLATES

-

-

-

... More
Supply, installation and connection of GI earth plates as per std. 7-51-0103, complete with anchor bolts, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge.

-

-

-

... More
GI earth plate as per std. 7-51-0103.

50

886

44300

... More
CABLES FOR NGR CONNECTION

-

-

-

... More
Connecting neutral of the transformer/Generator through following single core PVC/XLPE insulated cable to NGR including supply of Al/Cu conductor, PVC/XLPE insulated, unarmoured and PVC sheathed cables, clamps, necessary supports, all hardware, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in- Charge.

-

-

-

... More
6.6 kV 185 mm² XLPE insulated Aluminium conductor cable for NGR connection

40

1226

49040

... More
EARTHING CONNECTORS

-

-

-

... More
Supply and installation of MS ear of width 50 mm and thickness 5 mm for earthing of process vessels, steel structures, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge.

-

-

-

... More
Minimum 75mm to maximum 300 mm long

5

770

3850

... More
CIVIL WORKS/M.S. CHEQUERED PLATE

-

-

-

... More
Supply and laying of 40 mm size gravel in one layer of 100/150 mm thick including dressing of soil surface and laying the aggregate in uniform layer and density, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge ( Aggregate will be measured in boxes of size 1.5 m x 1.5 m x 0.5 m which shall be taken as 1 cubic metre, the boxes are to be furnished by the contractor free of cost for measuring purposes).

-

-

-

... More
40 mm size gravel.

12

1495

17940

... More
Supply and spreading of approved fine river sand/stone dust in cable trenches, including all labour and materials, specifications of this tender and directions of Engineer-in-Charge.

-

-

-

... More
Fine river sand.

400

1405

562000

... More
Supply and spreading of approved FLY ASH BRICKS - TYPE-5 of 75 mm thickness in cable trenches for cable protection, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. (Actual area of laid brick surfaces shall be measured).

-

-

-

... More
Bricks.

100

510

51000

... More
Providing and laying plain cement concrete for all depths below and up to a plinth level in foundations including tamping, ramming, vibrating, curing, shuttering etc. all as specified in any shape, position, thickness and finishing the top surface rough or smooth as specified and directed, including supply of all materials and all complete for concrete of M-15 grade with 20 mm and down size graded crushed stone aggregates, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge.

-

-

-

... More
Plain cement concrete.

50

5818

290900

... More
Supply, fabrication and installation of 6 mm thick M.S. chequered plate for covering floor cut- outs/cable trenches etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge.

-

-

-

... More
6 mm thick M.S. chequered plate.

15

3625

54375

... More
Making through and through cut outs in pockets of following shape and size in the RCC floor/ walls of trenches/ buildings of thickness above 200 mm and upto 400 mm for facilitating cable/ duct entries, using concrete cutting machines and making cut out good using plastering and painting including all material and labour as per approved drawings, specification of this tender and directions of Engineer-in-charge.

-

-

-

... More
Circular Cut Out of diameter 150 mm

2

922

1844

... More
Rectangular Cut Out of length 200 mm width 200 mm

2

2238

4476

... More
Making through and through cut outs in pockets of following shape and size in the brick work of buildings of thickness upto 350 mm for facilitating cable/ duct entries, using concrete cutting machines and making cut out good using plastering and painting including all material and labour as per approved drawings, specification of this tender and directions of Engineer-in-charge.

-

-

-

... More
Circular Cut Out of diameter 150 mm

2

743

1486

... More
Rectangular Cut Out of length 200 mm width 200 mm

2

1477

2954

... More
PAINTING & MARKING

-

-

-

... More
Letter painting and marking of all buses of switchboards, all incomers, bus couplers, outgoings with details of Tag No, feeder rating in KW/Amp, sending end source, in the front of the panels and bus bar, panel nos.etc. on the rear side of the panels for all switchboards, all other substation equipment viz.transformers, capacitors, neutral grounding resistors, VFD panels, other panels, etc for equipment housed in electrical substations including supply of all material such as stickers, enamel paints, stencil, etc including supply of all labour, materials as per the specification of this tender and directions of Engineer-in-Charge.

-

-

-

... More
Each alphabet/character upto 2 inch in height/length

1000

54

54000

... More
Each alphabet/character above 2 inch and Upto 4 inch in height/length

1000

63

63000

... More
Each alphabet/character above 4 inch and Upto 8 inch in height/length

500

72

36000

... More
Each alphabet/character above 8 inch and Upto 12 inch in height/length

500

81

40500

... More
Letter painting of tag nos., applicable circuit nos. for identification with red/black/white paint for all outdoor equipment in safe and hazardous areas viz. light fittings, control gear boxes, lighting/power panels, welding receptacles, convenience receptacles, local control stations, fire alarm manual call points, fire alarm detectors, motors, field call stations, loud speakers, etc. including supply of enamel paint, all hardware as required, supply of all labour, materials as per the specification of this tender and directions of Engineer-in-Charge.

-

-

-

... More
Each alphabet/character upto 2 inch in height/length

1000

45

45000

... More
Each alphabet/character above 2 inch and Upto 4 inch in height/length

1000

54

54000

... More
Each alphabet/character above 4 inch and Upto 8 inch in height/length

500

63

31500

... More
Each alphabet/character above 8 inch and Upto 12 inch in height/length

500

72

36000

... More
INSTRUMENTATION

-

-

-

... More
PRESSURE GAUGES AND ACCESSORIES (Excl. supply of Impulse pipe/Tubing materials)

-

-

-

... More
Installation of Line mounted or Remote mounted or Local Gauge Board mounted Pressure gauge/ Pressure gauge with Pulsation Dampener/ Syphon/ Over-range Protector (direct/ surface mounted/ diaphragm seal type) inclusive of mounting of instrument, supply and erection of supports/tray, mounting on support (if support required) , laying of capillary on tray, fabrication and installation of manifolds/ impulse lines with supports as per standards indicated below, hydraulic testing and painting of supports but exclusive of Supply of Instrument, Gauge Board, Yoke, Piping material and Calibration.

-

-

-

... More
In Stainless Steel as per Standard 7-52-1207

18

5773

103914

... More
In Carbon Steel as per Standard 7-52-0432/1112

16

3356

53696

... More
PRESSURE GAUGES AND ACCESSORIES (Incl. supply of Impulse pipe/Tubing material)

-

-

-

... More
Installation of Line mounted or Remote mounted or Local Gauge Board mounted Pressure gauge/ Pressure gauge with Pulsation Dampener/ Syphon/ Overrange Protector (direct/ surface mounted/ diaphragm seal type) inclusive of mounting of instrument, supply of piping and tubing materials such as valves, fittings, pipes, tubes, compression fittings, as per specification, supply and erection of supports, mounting on support, (if support required), laying of capillary on supports, fabrication and installation of manifolds/ impulse lines with supports as per standards indicated below, hydraulic testing and painting of supports but exclusive of Supply of Instrument, Gauge Board, Yoke, and Calibration.

-

-

-

... More
In Carbon Steel as per Standard 7-52-1281

2

4144

8288

... More
In Carbon Steel as per Standard 7-52-0432/1112

19

3186

60534

... More
In Stainless Steel as per Standard 7-52-1207

24

5477

131448

... More
PRESSURE INSTRUMENTS (Excl. supply Impulse pipe/Tubing materials)

-

-

-

... More
Installation of Pressure Transmitters/ Pressure Switches (with or without Pulsation Dampener, Over-range Protector)/ Diaphragm seal type Pressure Transmitters/ Diaphragm seal type Pressure Switches including mounting on Yoke/ Surface, supply of supports for capillary, supply and erection of supports for impulse lines wherever required, fabrication and installation of manifolds/ impulse lines with supports as per Standard indicated below, laying of capillary on supports, hydraulic testing and painting of supports but exclusive of Supply of Instrument, Piping/tubing materials, all Electrical/ Pneumatic connections, Yoke and Calibration.

-

-

-

... More
In Stainless Steel as per Standard 7-52-1258

99

9648

955152

... More
In Carbon Steel as per Standard 7-52-2129

71

7787

552877

... More
PRESS.INSTRUMENTS (Incl. supply of Impulse pipe/Tubing material)

-

-

-

... More
Installation of Pressure Transmitters/ Pressure Switches (with or without Pulsation Dampener, Overrange Protector)/ Diaphragm seal type Pressure Transmitters/ Diaphragm seal type Pressure Switches including mounting on Yoke/ Surface, supply of piping & tubing materials such as valves, fittings, pipes, tubes, compression fittings as per specifications enclosed, supply of supports for capillary, supply and erection of supports for impulse lines wherever required, fabrication and installation of manifolds/ impulse lines with supports as per Standard indicated below, laying of capillary on supports, hydraulic testing and painting of supports but exclusive of Supply of Instrument, all Electrical/ Pneumatic connections, Yoke and Calibration.

-

-

-

... More
In Stainless Steel as per Standard 7-52-1199

4

13819

55276

... More
In Stainless Steel as per Standard 7-52-1258

19

9648

183312

... More
In Carbon Steel as per Standard 7-52-1211

11

11725

128975

... More
In Carbon Steel as per Standard 7-52-2129

10

7787

77870

... More
In Stainless Steel as per Standard 7-52-2110

2

8565

17130

... More
DIFFERENTIAL PRESSURE INSTRUMENTS (Excl. supply of Impulse pipe/Tubing materials)

-

-

-

... More
Installation of Differential Pressure Transmitters (including one side capillary type)/ Differential Pressure Switch(including one side capillary type)/ Diaphragm seal type DP Transmitters/ Diaphragm seal type DP Switch including mounting on Yoke/ Surface, supply and erection of supports for impulse lines wherever required, fabrication and installation of manifolds/ impulse lines with supports as per Standard indicated below, supply and fabricating of supports for capillary, laying of capillary on supports, painting, installation of flushing connection, hydraulic testing of impulse lines as per standard indicated below but exclusive of Supply of Instrument, Piping material, all Electrical/ Pneumatic connections, Yoke and Calibration.

-

-

-

... More
In Carbon Steel as per Standard 7-52-1235

6

27835

167010

... More
In Stainless Steel as per Standard 7-52-1200

9

34315

308835

... More
DIFFERENTIAL PRESSURE INSTRUMENTS (Incl. supply of Impulse pipe/Tubing materials)

-

-

-

... More
Installation of Differential Pressure Transmitters (including one side capillary type)/ Differential Pressure Switch(including one side capillary type)/ Diaphragm seal type DP Transmitters/ Diaphragm seal type DP Switch including mounting on Yoke/ Surface, supply of piping & tubing materials such as valves, fittings, pipes, tubes, compression fittings as per specifications enclosed, ,supply and erection of supports for impulse lines wherever required, fabrication and installation of manifolds/ impulse lines with supports as per Standard indicated below, supply and fabricating of supports for capillary, laying of capillary on supports, painting, installation of flushing connection, hydraulic testing of impulse lines as per standard indicated below but exclusive of Supply of Instrument, all Electrical/ Pneumatic connections, Yoke and Calibration.

-

-

-

... More
In Stainless Steel as per Standard 7-52-1259

4

34315

137260

... More
DIFFERENTIAL PRESSURE (FLOW) TRANSMITTERS (Incl. supply of Impulse pipe/Tubing material)

-

-

-

... More
Installation of Differential pressure(with or without integral manifold)/ Diaphragm Seal Type Differential Pressure flow instruments including Mounting on Yoke, supply of piping & tubing materials such as valves, fittings, pipes, tubes, compressive fittings as per specifications enclosed, supply of supports for impulse lines/ manifolds/ capillary, fabrication and Installation of manifolds/ impulse lines with supports as per Standard indicated below, laying of capillary on supports, hydraulic testing and painting of supports but exclusive of Supply of Instruments, all Electrical/ Pneumatic connections, Yoke and Calibration.

-

-

-

... More
In Carbon Steel as per Standard 7-52-1379

21

26582

558222

... More
In Carbon Steel as per Standard 7-52-1357

24

32847

788328

... More
In Carbon Steel as per Standard 7-52-1344

2

39112

78224

... More
In Stainless Steel as per Standard 7-52-1355

2

39953

79906

... More
THERMAL MASS FLOWMETERS

-

-

-

... More
Installation of Thermal mass flow meter In-line/ Online type including removal and re-installation for line testing. Installation of Yoke/ Instrument (if required), filters and plug valve with related tubing inside the electrical tracing/heater box for Thermal Mass flowmeter including mounting/laying of electrical tracing lines/box on wall or Yoke (if required), testing and supporting inside the box, termination of interconnection cables, but exclusive of Supply of Instrument, Yoke, filter, box, plug valves, all electrical/pneumatic connections and Calibration.

-

-

-

... More
Thermal Mass flowmeters

1

5880

5880

... More
SPECIAL LEVEL/ GUIDED WAVE / ECCLIPSE TYPE RADAR LEVEL INSTRUMENTS

-

-

-

... More
Installation of Guided Wave/ Ecclipse type radar level instruments with or without controllers including installation of instruments on nozzles, changing of head orientation wherever required, fabrication and installation of primary piping, drain valve / vent valve assembly as per standard and hydraulic testing of instrument but exclusive of supply of instruments, piping materials, all electrical/ pneumatic connections and calibration.

-

-

-

... More
In Carbon Steel as per Standard 7-52-1526

20

6713

134260

... More
In Stainless Steel as per Standard 7-52-1526

86

6713

577318

... More
MAGNETIC LEVEL GAUGES

-

-

-

... More
Installation of Magnetic Level Gauges on Vessel/ Piping/ Stand pipes with minor modification wherever required, providing intermediate supports wherever necessary fabrication and installation of drain valve/ vent valve assembly as per Standard Nos. indicated below, hydraulic testing of gauge, exclusive of Supply of Instruments, Piping materials and Calibration.

-

-

-

... More
In Carbon Steel as per Standard 7-52-1526A

16

4475

71600

... More
In Stainless Steel as per Standard 7-52-1526A

14

4475

62650

... More
RADAR LEVEL INSTRUMENTS

-

-

-

... More
Installation of radar sensor and antenna, flanged type connection on equipment nozzle/ rail mounting with/without still well, but exclusive of supply of instruments. Installation of electronics units (total system for indication, transmission, marshalling etc. for one tank), including mounting on Yoke, supply of angle tray with supports, fabrication and erection of supports and laying of cable up to instrument/probe with clamps, termination of cables at both ends, but exclusive of supply of Instruments, supply of yokes and Calibration.

-

-

-

... More
Installation of radar type of level instruments

4

6131

24524

... More
DISMANTLING OF EXISTING INSTRUMENTS

-

-

-

... More
Disconnection, Dismantling, removal of existing instruments with associated accessories presently installed on the equipment, associated piping, connecting stairs, structures/ stairways/ operating platforms, etc., which are getting dismantled/ modified and transportation of the same to stores as per tender specifications, approved drawings, and instruction of Engineer-in- charge. This also includes removal of impulse lines/ lead lines/ purge gas lines/ purge oil lines with pipe fittings, tubes, tube fittings, accessories, supports, trays, cables, cable glands, etc.,

-

-

-

... More
Instruments

9

2515

22635

... More
TEMPERATURE INSTRUMENTS

-

-

-

... More
Installation of Temperature Indicators/ Gauges (Filled system/ Bimetallic) RTD/ Thermocouple/ Temperature Switches/ Temperature transmitters with flanged thermowell inclusive of installation of machined/ built-up thermowells on the nozzle and installation of Instruments, Electrical/ Pneumatic connection but exclusive of Supply of Instruments/ Elements/ Thermowell, and Calibration.

-

-

-

... More
Temperature Indicator/ Gauges (Filled System) with thermowell on flanged wells

4

1056

4224

... More
Temperature Indicator/ Gauges (Bimetallic Type) with thermowell on flanged wells

60

1056

63360

... More
TEMPERATURE TRANSMITTERS (REMOTE MOUNTED)

-

-

-

... More
Thermocouple/ RTD element with thermowell, along with Temperature Transmitter remote mounted. Installation of transmitter including mounting on yoke, fabrication and erection of supports with clamps and laying of extension/RTD cable upto thermocouple, termination of cables at both ends, painting of supports but exclusive of Supply of Instruments, Cable, Yoke and Calibration.

-

-

-

... More
Temperature Transmitter and RTD with flanged well

144

1960

282240

... More
DETECTOR SYSTEMS

-

-

-

... More
Installation of Fire and Gas detectors/monitors, beacon lights and hooters including earthing of Fire and Gas detector, supply of supports but exclusive of Supply of Detectors, Yoke and Calibration.

-

-

-

... More
LEL Detectors

37

1575

58275

... More
H2S Detectors

28

1575

44100

... More
Beacon Lights

12

1298

15576

... More
Hooters

8

1298

10384

... More
Flame Detector

9

1575

14175

... More
MISCELLANEOUS ITEMS AND DEVICES

-

-

-

... More
Mounting of Miscellaneous instrument items as listed below on Yoke; fabrication and erection of Supports and including installation of instrument items, painting of supports but exclusive of Supply of Instrument items, Piping/ Tubing material / Calibration and supply and erection of Yoke support.

-

-

-

... More
Pressure Switch

1

1029

1029

... More
Level Switch

20

1029

20580

... More
Key Phasor/Axial Displacement/ Temperature/ Vibration probe/ Vibration Switches for Vibration Monitoring System complete with cable laying and other accessories like junction boxes

10

1495

14950

... More
Electronic Local Indicator.

8

1056

8448

... More
LOCAL PANELS/ CABINETS/ GAUGE BOARDS

-

-

-

... More
Installation of local panels in field (Pressurized/ Non-pressurized/ Flame- proof) /PLC cabinets/ marshalling cabinets / Radiation Pyrometer monitor / Gas monitor panels/ local gauge board inside control room with or without instruments of following sizes including supply, fabrication, painting and installation of base frames and installation of panel but exclusive of pneumatic/ electrical connections, supplying of local panels/ local gauge boards.

-

-

-

... More
Size 2200x1200x800mm 2200x800x600mm

30

15135

454050

... More
CALIBRATION/ TESTING

-

-

-

... More
Cleaning, adjusting stroke/ positioner, stroke speed checking of Control and On-off (Shutdown) valves. Providing equipments, necessary test jig, Instrument Air, Nitrogen Cylinders, test reports, all consumable and loop testing. Excludes flow calibration

-

-

-

... More
Control Valves

31

1530

47430

... More
On-off valves (SDV/ ROV)

32

1244

39808

... More
Cleaning, set pressure tests of Pressure Relief and Thermal Relief Valves. Providing equipment, necessary test jig, Instrument Air, Nitrogen Cylinders, test reports, all consumable. Excludes flow calibration.

-

-

-

... More
Sizes upto 3/4" x 1" threaded

4

689

2756

... More
Inlet Sizes upto 2" flanged, rating 150# to 2500#

14

1495

20930

... More
Inlet Sizes 2-1/2" 3" 4" flanged, rating 150# to 1500#

24

1960

47040

... More
Inlet Size 6" flanged, rating 150# to 600#

4

2980

11920

... More
Inlet Size 8" flanged, rating 150# to 300#

6

4940

29640

... More
Cleaning, calibration of the instruments listed below including removal of instrument from reinstalled locations like panels, enclosures, racks, field etc., and fixing them back in respective places, providing equipments, necessary test jig, Instrument Air, Nitrogen Cylinders, test reports, all consumable, except for special imported test equipments for electronic instruments to be supplied by owner if available.

-

-

-

... More
Pressure switches

1

591

591

... More
Pressure gauges

79

609

48111

... More
Pressure transmitters

217

958

207886

... More
Temperature Transmitters

144

1056

152064

... More
Differential Pressure Transmitters for Flow, Level and D.P.

100

1056

105600

... More
Special Level Instruments/ Guided Wave / Ecclipse type Radar level instruments

106

1530

162180

... More
Level switches external/ internal float

20

1495

29900

... More
Tank Level Instrument (Radar type)

12

1495

17940

... More
Position Transmitter

2

689

1378

... More
LEL Detectors

37

1056

39072

... More
H2S Detectors

28

1056

29568

... More
UV/IR Flame Detector

9

1029

9261

... More
Cleaning, checking and functional tests for flowmeters. Providing equipments, necessary test jig, Instrument Air, test reports, all consumable, except for special imported test equipments for electronic instruments to be supplied by owner if available. Excludes flow calibration.

-

-

-

... More
Thermal Mass flowmeters

1

2980

2980

... More
Ultrasonic flowmeters

30

3070

92100

... More
LOOP CHECKING

-

-

-

... More
Loop checking (excluding calibration/ testing) of the instruments listed below including verifying the functional performance of all elements comprising the loop, thereby ensuring proper interconnections and operation, with all other specifications inline with clause 4.13 of Standard specification for Erection tender 6-52-0060.

-

-

-

... More
Loop Powered Transmitter

8

385

3080

... More
Differential Pressure Transmitters for Flow, Level and D.P.

100

385

38500

... More
Special Level Instruments/ Guided Wave Radar level instruments

106

385

40810

... More
Temperature Transmitters

144

385

55440

... More
Pressure transmitters

217

385

83545

... More
Tank Level Instruments (Radar type)

4

385

1540

... More
Electronic Local Indicator

8

385

3080

... More
Gas Detectors

45

385

17325

... More
Speed / Vibration Transmitter

2

385

770

... More
Hooter / Beacon

16

385

6160

... More
Flame detectors (UVIR, Heat, Smoke)

9

385

3465

... More
Loop checking (excluding calibration/ testing) of the flowmeters listed below including verifying the functional performance of all elements comprising the loop, thereby ensuring proper interconnections and operation, with all other specifications inline with clause 4.13 of Standard specification for Erection tender 6-52-0060.

-

-

-

... More
Thermal Mass flowmeters

1

385

385

... More
Ultrasonic flowmeters

30

385

11550

... More
SUPPLY ITEMS

-

-

-

... More
Supply of Instrument items as per specifications enclosed elsewhere in the Tender.

-

-

-

... More
RTD Cable, IS

500

313

156500

... More
Thermal Mass flowmeter

1

26850

26850

... More
Multi Cable transit frames complete with all insert blocks and stay plates of size 6 + 6 x 10

2

179002

358004

... More
Supply of 6 Way air manifold of SS along with its piping , tubing, valves and associated fittings as per Installation Standard 7-52-1905

10

11519

115190

... More
Power cable size 2C x 4 mm²

1000

3464

3464000

... More
Control Cable as per Standard Specification 6-52-0046, Size 12P X 2.5 mm2, IS, Fire Safe

7000

474

3318000

... More
Control Cable as per Standard Specification 6-52-0046, Size 1P X 1.5 mm2, IS, Fire Safe

1500

81

121500

... More
Multi Cable transit frames complete with all insert blocks and stay plates of size 6 + 6 x 4

1

161102

161102

... More
Signal Cable as per Standard Specification 6-52-0046 size, 1P X 1.5 mm2, IS, FRLS

10000

63

630000

... More
Signal Cable as per Standard Specification 6-52-0046, Size 12P X 1.5 mm2 , IS, FRLS

45000

385

17325000

... More
Control Cable as per Standard Specification 6-52-0046, Size 12P X 1.5 mm2 , NIS, FRLS

18000

385

6930000

... More
Control cables as per Standard Specification 6-52-0046 size 1P X 1.5 mm2 , NIS, FRLS

5000

81

405000

... More
Supply of Junction boxes of various types and specifications

-

-

-

... More
Junction Box, Weatherproof type for 12 Pair Cable

55

9263

509465

... More
Junction Box, Weatherproof + Flameproof (Gas Groups -IIA/IIB) type for 12 Pair Cable

20

13855

277100

... More
Supply of Cable glands of various types and specifications

-

-

-

... More
Double compression type Cable gland, weatherproof + Flameproof (Gas Group IIA/IIB) type,Ni plated Brass material with PVC shroud, 1 1/2" NPTM

100

680

68000

... More
Double compression type Cable gland, weatherproof + Flameproof (Gas Group IIA/IIB) type,Ni plated Brass material with PVC shroud, 1" NPTM

27

331

8937

... More
Double compression type Cable gland, weatherproof + Flameproof (Gas Group IIA/IIB) type,Ni plated Brass material with PVC shroud, 1/2" NPTM

1000

152

152000

... More
Double compression type Cable gland, weatherproof + Flameproof (Gas Group IIA/IIB) type,Ni plated Brass material with PVC shroud, 3/4" NPTM

60

215

12900

... More
Double compression type Cable gland, weatherproof + Flameproof (Gas Group IIA/IIB) type, Ni plated Brass material with PVC shroud, 1 1/2" ET with check nut

100

465

46500

... More
Double compression type Cable gland, weatherproof + Flameproof (Gas Group IIA/IIB) type, Ni plated Brass material with PVC shroud, 1" ET with check nut

27

152

4104

... More
JUNCTION BOX INSTALLATION

-

-

-

... More
Installation of weatherproof junction boxes including supply, fabrication and installation of supports, installation of junction boxes, supply of 14 SWG GI wire (max. length 10 m per Junction Box), laying and connection, screwing plugs for unused entries and painting but exclusive of supply of junction boxes and glands/ fittings.

-

-

-

... More
For cable size 12Px0.5/1.0/1.5/2.5 mm² Signal/Alarm/ Control

100

3884

388400

... More
Installation of weatherproof and flameproof junction boxes including supply, fabrication and installation of supports, installation of junction boxes, supply of 14 SWG GI wire (max. length 10 m per Junction Box), laying and connection, screwing plugs for unused entries and painting but exclusive of supply of junction boxes and glands/ fittings.

-

-

-

... More
For cable size 12P x 0.5/1.0/1.5/2.5 mm²/16 AWG Signal/FF/Alarm/ Control

50

3884

194200

... More
For cable size 8T x 1.5/ 2.5 mm² RTD/ Gas Detector

20

4484

89680

... More
Installation of Multi Cable transit frames complete with all insert blocks, stay plates, unused blocks with cables piece inserted, end packing etc. on wall for Cable entry including necessary civil works, welding, supply and installation of additional steel plate for unused portion of cutouts, fixing of frames, pulling cables to blocks and installation of blocks on frames as per manufacturer's recommendation.

-

-

-

... More
6 + 6 x 10

2

20218

40436

... More
6 + 6 x 4

1

17847

17847

... More
LAYING OF CABLES

-

-

-

... More
Laying of instrumentation cables for signal, alarm, shutdown, control and signal cable on ducts, main trays, perforated trays, angle trays, trenches (including opening of cable duct covers if required through IRCs {Instrument Road Crossings}) including clamping, glanding the cables, termination at both ends including shield/ drain/ communication wire, providing and fixing identifying tags and megger testing but exclusive of supply of cables and erection of ducts, main tray, perforated tray/ angle trays and preparation of cable trench.

-

-

-

... More
Signal/ Alarm/ Control Cables of cable sizes 12C / 6P x 1.5 / 2.5 mm²

90000

36

3240000

... More
Signal / Alarm / Control Cables of cable sizes 1P x 1.5 / 2.5 mm²

20000

27

540000

... More
Laying of thermocouple/ RTD/ LEL Detector/ H2S Detector cables on ducts, main trays, perforated trays, angle trays, trenches (including through IRCs {Instrument Road Crossings}) including opening of cable duct covers if required clamping, glanding the cables, termination at both ends including shield/ drain/communication wire providing and fixing of identifying tags and megger testing but exclusive of supply of multi cables and erection of ducts, main tray, perforated tray/angle tray and preparation of cable trench.

-

-

-

... More
8 Triad/ Quad x 1.5 mm² RTD/ LEL Cable

7000

36

252000

... More
1 Triad/ Quad x 1.5 mm² RTD/ LEL Cable

2000

27

54000

... More
Laying of power cables on ducts, main trays, perforated trays, angle trays, trenches (including through IRCs) including opening of cable duct covers if required clamping, glanding the cables, termination at both ends including shield/ drain/ communication wire providing and fixing of identifying tags and megger testing but exclusive of supply of multi cables and erection of ducts, main tray, perforated tray/ angle tray and preparation of cable trench

-

-

-

... More
For cable size 2C x 2.5 mm²

4000

27

108000

... More
EARTHING

-

-

-

... More
Supply, laying and termination of both ends of earthing cables from earth grid pit to the DCS/ Local panels/ Barrier earth bus bars in trays/ conduits/ trenches as required.

-

-

-

... More
At both ends of earth grid/ Instruments of GI wire (12 AWG) in trays and conduits as required excluding earth-pit preparation and electrode installation.

200

54

10800

... More
PIPING / TUBING / FABRICATION WORK

-

-

-

... More
Erection of SS Air distribution manifold and fittings including supply/ fabrication/ erection of supports, pneumatic testing and painting of supports but exclusive of supply of SS Air distribution manifold and fittings

-

-

-

... More
Installation of 6-way Air Manifold (1/2") as per Standard 7-52-1905

6

2291

13746

... More
Tubing Hook-up of Control valves/ Pneumatic Transmitters etc. with air filter regulator / positioner / solenoid valves / Current to Pneumatic converters etc. as per Standards

-

-

-

... More
7-52-0207/1915 (Control valve and Solenoid Valve) including supply of erection items

28

1772

49616

... More
7-52-0212/1920 (Control valve with Smart Positioners) including supply of erection items

18

1584

28512

... More
STRUCTURAL

-

-

-

... More
Supply, Fabrication, and Erection of Galvanised Iron angle/channel trays and its supports as per drawing.

-

-

-

... More
Trays of 50 X 50 X 6mm angle

500

564

282000

... More
Supply and erection of FRP ladder tray and its supports as per specifications including bends, tees and elbows including supply and installation of supports

-

-

-

... More
Run of ladder tray 600mm width

1000

1880

1880000

... More
Supply and erection of prefabricated FRP perforated trays with covers as per specifications enclosed elsewhere in tender document and its support including tees, bends and elbows

-

-

-

... More
tray of 150mm (W) x 40mm (H)

900

985

886500

... More
tray of 300mm (W) x 40mm (H)

2200

1146

2521200

... More
tray of 100 mm (W) X 30 mm (H)

600

627

376200

... More
tray of 60 mm (W) X 20 mm (H)

3000

448

1344000

... More
CANOPY FOR INSTRUMENTS AND JUNCTION BOXES

-

-

-

... More
Supply of Prefabricated FRP canopies along with mounting accessories for local instruments, Transmitters, Junction Box etc. for mounting on the stanchion and alignment as per standard 7-52-0105

-

-

-

... More
FRP Canopy For Junction Box - Front Side Open

100

3831

383100

... More
FRP Canopy (All sides closed) - Field Instruments

400

2560

1024000

... More
GENERAL SITE WORK

-

-

-

... More
Supply of Yoke supports for transmitters/ preamplifiers (wherever applicable) including supply, fabrication and erection of instrument yoke of all types and painting of yoke supports but exclusive of mounting of Instrument on supports.

-

-

-

... More
4" Yoke supports

10

3133

31330

... More
2" Yoke supports as per standard 7-52-0101

500

2425

1212500

... More
Identification of instrument items wherever required including supply of approved colour of paint/ paints (Fluorescent), painting of tag number (approx 25-50 mm high) on instrument item like transmitter, switches, level gauges, control valves etc. as specified by Engineer-in-Charge.

-

-

-

... More
Identification of instrument items

1000

304

304000

... More
Contractor to provide & mobilise following Manpower as per the instructions of B AND R Engineer in- charge. However, 2 weeks' notice shall be given for mobilisation and 1 day notice Shall be given for demobilisation. Note that quoted rate of manpower deployment shall be inclusive of required PPEs and facilities required for functioning at site. (1 Man-Month should be considered as 30 man-days.

-

-

-

... More
Lead Safety Officer

10

51000

510000

... More
QA/QC Officer

10

42500

425000

... More
Electrical Engineer

12

42500

510000

... More
Instrumentation Engineer

12

42500

510000

... More
"NOTE:- THE ABOVE RATE SHALL BE INCLUSIVE OF ALL TAXES & DUTIES, ROYALTIES, CESS, FEE, ENVIORMENTAL & POLLUTION, FITNESS & SAFETY CLEARANCE CHARGES (IF ANY), OR ANY OTHER INCIDENTAL CHARGES ETC BUT EXCLUDING GST."

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.