Automotive Research Association Of India Tender
Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.
Automotive Research Association Of India - ARAI Tender
Electrical and Electronics
Eprocure
Opening Date3 Oct 2022
Closing Date5 Nov 2022
Tender AmountRefer Documents
Costs
EMD
₹ 2,40,000Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2022_ARAI_716036_1Bid Award Id
ViewTender No
ID-1406-PR-10020128Tender Authority
Automotive Research Association Of India ViewPurchaser Address
-Website
http://https://www.araiindia.com/home
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
22kV, 3C X 300Sq.mm (Earthed)
300
-
-
HT CABLE TERMINATION: Supply and making HT XLPE cable end termination as per IS:13573 using Raychem or Equivalent make heat shrinkable kit (Indoor/ out door) including making holes in gland plates and fixing the same, installation of cable glands, fixing of glands, minor modification on terminals, identifying the cable, cutting , stripping of insulation, separation of cable cores, removing of armour, earthing of armour, crimping of lugs on the conductor, connections of cable, dressing of the core etc., complete with testing and commissioning with all labours, tools and tackles, consumables (Like insulation tape, crimping paste etc..) as per the drawings/ specifications and the direction of Engineer-in-charge. The termination shall be as per manufacturer's Recommendations. Jointer should be certified jointer from manufacturer. Returning of unused cables to store/scrap yard are to be done by contractor.
-
-
-
22kV, 3C X 300Sq.mm Earthed Indoor
10
-
-
22kV, 3C X 300Sq.mm Earthed Outdoor
6
-
-
METERING KIOSK: Supplying, Installation, Testing, and commissioning of outdoor type 22 KV Metering Kiosk with CT PT, Energy meter etc. all as per MSEDCL requirements and Technical Specifications. Scope includes Testing and approval of Metering Kiosk, Energy meter from MSEDCL before dispatch of the unit from Manufactureing Unit, as per their requirement.
2
-
-
22 kV Medium Voltage VCB PANELs
-
-
-
Supply, Installation, Testing, Commissioning, Transportation, handling, unpacking, erection of Outdoor type 22KV VCB Panel with minimum 100mm base frame, trollay and earth switch as per technical data sheet and tender specifications as listed below. Minor civil work, alignment and leveling, at different elevations, spot welding, fixing of bolts, application of touch-up paint and other associated works complete with all labour, tools & tackles, consumables etc.It also includes required fabrication work with proper size Angles / Channels etc for mounting of Switchboards / Panels, Proper alignment, tightening of bus bars with required torque as instructed by Manufacturer / engineer in charge. Any modification / alteration to be carried out in individual shipping section for proper Assembling / alignment is to be done by the Contractor. It also includes Transportation of unpacked wooden crates / covers / Material from work site to scrap yard in the scope of Contractor.
-
-
-
VCB Panel having following :
1
-
-
INCOMER
-
-
-
1 No. 1250A, 22kV,25KA, 3 Phase, 50Hz., metal clad, dead front, 25KA rupturing capacity, Fully Draw out type, Outdoor Vacuum Circuit Breaker (VCB) 1 set of 22kV/√3 /110/√3 50VA CL:0.2s. Potential Transformer with HRC fuses for metering and protection.
1 No. 22kV Energy Monitor Device ( Load Manager)with Ethernet Communication Port.
1 Set of 100/50/5A, CL-0.2S, 10VA Resin cast Current Transformer (for metering) 1 Set of 100/50/5A, CL-5P10, 10VA Resin cast Current Transformer 1 Set of Phase indicating lamps with HRC fuses
1 Nos. digital ammeter with inbuilt selector switch
1 Nos. 0-22 kV digital voltmeter with inbuilt selector switch
1 Nos. Protection relay (Protections - (50/51,50N/51N) having metering & Ethernet Communication Port. 1 set of indicating lamps to indicate OPEN, CLOSE, TRIP, SPRING CHARGED, TRIP CIRCUIT HEALTHY, TEST, CONTROL SUPPLY ON, SERVICE
Surge Arretor and Earth switch and Breaker trolley.
Push button for CLOSE and TRIP & TRIP CIRCUIT HEALTHY, Emergency , 8 window Alarm annunciator with separate hooter, accept and rest push buttons.
-
-
-
OUTGOINGS :
-
-
-
Outgoing - 2 Nos. 1250A, 22kV,25KA, 3 Phase, 50Hz., metal clad, dead front, 25KA rupturing capacity, Fully Draw out type, Vacuum Circuit Breaker (VCB) 2 Nos. 22kV Energy Monitor Device ( Load Manager)with Ethernet Communication Port. 2 Set of 50/5A, CL-0.2S, 15VA Resin cast Current Transformer 2 Set of 50/5A, CL-5P10, 15VA resin cast Current Transformer
2 Set of Phase indicating lamps with HRC fuses
2 Nos. digital ammeter with inbuilt selector switch
2 Nos. 0-22 kV digital voltmeter with inbuilt selector switch
2 Nos. Protection relay (Protections - 32,37,46,46BC,49,50/51N, 50/51P, 50BF, 51V, 59/27, 59N, 64, 67N, 67P, 81, 86,CTS OR eqv. to MiCOM P127) having metering & Ethernet Communication Port. 2 Set of Transformer Auxiliary relays.
2 set of indicating lamps to indicate OPEN, CLOSE, TRIP, SPRING CHARGED, TRIP CIRCUIT HEALTHY, TEST, CONTROL SUPPLY ON, SERVICE
Push button for CLOSE and TRIP & TRIP CIRCUIT HEALTHY, Emergency , 8 window Alarm annunciator with separate hooter, accept and rest push buttons. Control voltage should be considered as 24 V DC Power Supply with suitable rating power pack (30min backup).
Also Panel should having provision for future extension as per SLD.
-
-
-
CIVIL WORK
-
-
-
HUME PIPES
Supplying and laying of NP2 Class RCC Hume pipe below ground level. The rate shall include laying of pipe, making the chase in the brick wall, embedding the pipes. Any specials like nipples, collars shall also be included in this item rate only.
-
-
-
300 mm dia RCC hume pipe
60
-
-
150mm Half round RCC hume pipe
160
-
-
Earthing
-
-
-
Supply, Installation, Testing and connection of Eco Safe Maintenance Free Electrode of 25 mm diameter Low Carbon Steel with 250 micron Molecular Copper Bonded Earthing Rod of 3 Mts Length along with Carbon Based environment friendly back fill Ground Enhancing compound required to fill up the excavated earth with required quanitity. It also includes necessary accessories like nuts and bolts, test link, insulators etc. This item includes 100 mm dia drill in ground, average 8 meter depth in back filled earth and 4 meter depth in vergin earth. It also includes suitable casing for the drill at the backfilled area if required, Installation of earth electrode, connection of earth strip from electrode to test link, testing and connection complete as per code of practice IS:3043 complete. (Electrode type)
22
-
-
Excavation, Supply and construction of masnory chamber for earth pit with Cast Iron Heavy Duty covers, Test Links and all necessary accessories. (OD Size 450Lx 450Wx 300D)
22
-
-
Supply, Laying, Running, Fixing, Jointing of below listed sizes of earth conductor wires / Strips in ground, along with cable trays or on wall with proper readymade clamping, fixing accessories in complete
-
-
-
25 x 3 GI STRIP
200
-
-
25 x 3 COPPER FLAT
200
-
-
Soil Excavation :- Earth work in excavation for Electrical Cable trench of required width & chamber work upto 1.5m in depth in all type of soil including bituminous road surface,concrete blocks,stone soiling,boulder filling using pickaxes or mechanical means including shoring & dewatering by bailing or by normal pumping if required, dressing section to the required grade,camber,side slopes. ( Measurement based on solid volumn of excavated quantities of specified width as per drawing ) complete as directed
84
-
-
Rock Excavation :-Excavation in all kinds and condition of hard rock by chiselling or sledging or any other means including shoring & dewatering by bailing or pumping if required preparing the bed of the trench/ chamber to the required grade,camber, side slopes. ( Measurement based on soild volumn of excavated quantities of specified width as per drawing) complete as directed
56
-
-
Sand Bed :-Providing & laying sand bed of 75mm thick in trench. The sand shall be crush sand Complete as directed.
10
-
-
Soil Filling :- Providing & laying earth work in trench filling with approved murrum or equivalent material available from excavation including spreading in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming & watering,by using mechanical compactor ( Plate or Roller)as approved by engineer so as to attain 95% Standard proctor density,incl. soil testing for compaction etc. complete to required level & slopes as spcified, directed. ( measurement based on soild volumn of filling quantities of specified width as per drawing & levels recorded) .The type of compactor to be used shall be approved by the engineer based on the trial.
105
-
-
Disposal of excess material :-Disposal of unwanted materials from excavation at contractor risk & cost to the location suitable to contractor outside working area.
35
-
-
Manhole of size 1200mm X 1200mm , depth in cm (Cement Morter) 1:4 , RCC coping at top 230mm wide X 80mm thick in cm 1:2:4 with 8mm dia HYSD reinforcement @ 150mm c/c, both way PCC 1:3:6 of 80mm thick bed.Inside plaster of 12mm thick in cm 1:3 finish work with neat cement Heavy duty RCC manhole cover & frame inclusive of excoriation & backfilling etc Complete as directed.
2
-
-
PCC 1:3:6: Providing and laying in position plain cement concrete of specified volume proportion including the cost of centring and shuttering - All work upto plinth level to the required level & thickness, consolidation, curing, dewatering if necessary etc. complete.
19
-
-
RCC M-20 grade Design Mix Work for road crossing- Providing and laying in position machine batched, machine mixed (non tilting with automatic water dispenser arrangement) concrete or by RMC (with prior approval) and machine vibrated, designed mix cement concrete as per IS 456-2000 of specified grade for reinforced cement concrete structural elements, including the cost of centring, shuttering, scaffolding, lifting, pouring, finishing, admixtures in recommended proportions as per IS 9103 to accelerate, retard, setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in -charge to required level / shapes / slopes, curing, all lead, lift, depths etc. complete. (including fixing of Reinforcement steel work if required) For M-20 grade Reinforced Cement Concrete for road crossing as per detail specifications and directions-(Only site batching and mixing be allowed).Curing will be in contractor`s scope
15
-
-
Supply, cutting, welding, grouting, fastening, cleaning and painting (one coat of Zink phosphate primer & two coats of enamel paint)of MS Channels, angles, plate, supporting brackets/structures for cable trays support structure, Switchboards, etc. complete with necessary hardware's.
800
-
-
Supply, Installation, Testing and Commissioning of Power Cable Armoured 4C x 10Sq.mm Al. FR XLPE Cable underground cable
1500
-
-
Miscellaneous items
-
-
-
Supply and fixing of danger boards of appropriate voltage grade, size and style as required by Electrical Inspectorate.
1
-
-
Supply of Rubber checkered mat of size 2000 x 1000 x 12 mm thick, 22000 V grade.
5
-
-
Supply of Standard First aid box complete with all accessories.
1
-
-
Supply of Wooden framed glass fronted shock treatment chart as per IE rules fixed to wall.
1
-
-
Supplying of 4 nos. G.I. bucket round bottom duly painted,13 liters capacity & filled with dry sand on floor mounting stand for keeping 4 nos. of bucket 1500mm in length, 900mm in height made out of 30x30x4mm angle iron welded with 4 hooks & duly painted with one coat of red lead & two coats of sliver paint.
3
-
-
Supplying & Erecting CO2 type fire extinguisher 4.5 KG CAP confirming to IS 217185 & having complete erected with necessary clamps made from 50x6 mm M.S. flat with nuts & bolts grounded in wall complete.
3
-
-
a) Preparation, submission and obtaining all required sanctions including all approvals and completion certificate etc. from MSED Co. Ltd and Electrical Inspector regarding 1300 KVA Contract Demand including all necessary follow-up and co-ordination with respective offices including obtaining necessary sanctions for release of 22KV supply from MSEDCL including obtaining final completion and handing over the completion certificates with stamped drawings to ARAI, including all release order NoC for charging meter testing, Calibration of HT Meters and any other statutory approvals and Sanctions required for charging ,sanction extetnions etc. complete.
All Statutory charges paid by Contractor on behalf of ARAI shall be reimbursed at actuals on submission of original documents. b) Scope also includes, All necessary approvalas required for Road crossing from concern statutary authorities like PMRDA,ZP etc All Statutory charges will be borne by ARAI
1
-
-
Note : The tenderer must obtain for himself on his own expense all such information which may be necessary for the purpose of pricing the tender and for entering into contract and must examine the drawings, the specifications, the site of work and acquaint himself with all local conditions, means of access to work, nature of work and all matters pertaining thereto. All loaidng,umloaidng,shifting,transportation,crane,hydra etc required to complete project in totality is in vendor scope.
-
-
-
HT WORK AT Phalne Village -Necessary grass cutting and asscoiated permssions from local authorities/MSEDCl during installation work is in bidder scope
-
-
-
Supply, Installation, Testing and Commissioning of outdoor type 22KV, 800 Amps, Ring Main Unit MSEDCL Approved 3Way, suitable for MSEDCL network, confirming to inernational standards and complete with fault passage indiactor and other accessories. with 1 ISO+2 Breaker scada compatible motorized.
1
-
-
Providing and constructing RCC foundation for 3 way RMU using cement concrete (1:2:4) including cost of excavation etc complete as per the drawing and specifications complete. (Ref drawing attached)
1
-
-
Supply, Installation, Testing and Commissioning of RSJ 152 x 152 11m long pole, along with all required necessary MS Channels, supports, RCC foundations and material such as aluminium 100sq.mm (DOG) ACSR conductors, Insulator sets, HT Stray Sets-6nos, earthing 4Nos. making cut points on 3 poles. etc. and including all accessories as per MSEDCL standard specifcations and as per site condition in complete suitable for 22KV Supply.
3
-
-
HT CABLE AND ACCESSORIES : Supply, laying, Testing and Commissioning of 22kV grade aluminium conductor, screened, XLPE insulated, round wire GI armoured and PVC extruded inner sheathed and FR outer sheathed cable conforming to IS:7098. Cable laying in existing excavated trench, scope includes unloading, shifting up to site, de-railing, clamping of cables by ready made G.I. spacers, saddles or clamps fabricated out of M.S. strip 3 mm thick. Rate shall be inclusive of all necessary items for Cable Protections, CI Route Markers intervals not exceeding 30 m.
-
-
-
22kV, 3C X 95Sq.mm (Earthed)
100
-
-
HT CABLE TERMINATION: Supply and making HT XLPE cable end termination as per IS:13573 using Raychem or Equivalent make heat shrinkable kit (Indoor/ out door) including making holes in gland plates and fixing the same, installation of cable glands, fixing of glands, minor modification on terminals, identifying the cable, cutting , stripping of insulation, separation of cable cores, removing of armour, earthing of armour, crimping of lugs on the conductor, connections of cable, dressing of the core etc., complete with testing and commissioning with all labours, tools and tackles, consumables (Like insulation tape, crimping paste etc..) as per the drawings/ specifications and the direction of Engineer-in-charge. The termination shall be as per manufacturer's Recommendations. Jointer should be certified jointer from manufacturer. Returning of unused cables to store/scrap yard are to be done by contractor.
-
-
-
22kV, 3C X 95Sq.mm Earthed Indoor
3
-
-
22kV, 3C X 95Sq.mm Earthed Outdoor
3
-
-
Earthing
-
-
-
Earthig Sets for 22KV HT poles GI Wire 8 SWG GI Strip (25 x 3mm). Coal, Salt, including all accessories as per MSEDCL standard specifcations and as per site condition.
6
-
-
Supply, Installation, Testing and Commissioning of Power Cable Armoured 4C x 4Sq.mm Al. FR XLPE Cable underground cable.
500
-
-
Supply, Installation, Testing and Commissioning of Terminations for Power Cable Armoured 4C x 4Sq.mm Al. FR XLPE Cable
2
-
-
Following items are to be disconnected from their positions, clean and handover to MSEDCL and obtaning recipt of the same as per Engineers incharge suggestions.
-
-
-
11m long RSJ Pole, Stray with RCC foundation, Conductors etc. with all required arragements and as per site condition.
1
-
-
Note : The tenderer must obtain for himself on his own expense all such information which may be necessary for the purpose of pricing the tender and for entering into contract and must examine the drawings, the specifications, the site of work and acquaint himself with all local conditions, means of access to work, nature of work and all matters pertaining thereto. All loaidng,umloaidng,shifting,transportation,crane,hydra etc required to complete project in totality is in vendor scope.
-
-
-
TOTAL AMOUNT Rs.
-
-
-
GRAND TOTAL (In words) Rs. ------------------------------------------------------- only )
-
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements