Automotive Research Association Of India Tender

Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.

Automotive Research Association Of India - ARAI Tender

Works
Electrical and Electronics
Eprocure
Opening Date5 Sep 2024
Closing Date12 Oct 2024
Tender AmountRefer Documents 
Notes
Download

Costs

Summary

Electrical Installation And Allied Works For Cylinder Testing Facility At Arai

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
PANELS

-

-

-

... More
Supply Installation, testing and commissioning & loading, unloading & shifting of following Panels. Panels shall be fabricated out of 16/14 swg CRCA sheet steel, with necessory structural supports in form of structural steel sections. Panels shall be floor mounted.The panel shall be compartmental type with suitable size of bus bar and separate cable and busbarchambers. The cable chambers shall be free from any live open connections. Multifuction meters for all incoming feeders, Indication lamps for all incoming and outgoing feeders for phase identifications and for indication of Switch status.

-

-

-

... More
FORM (AS PER IEC STANDARDS PROTOTYPE DESIGN BY OEM)

-

-

-

... More
14 SWG CRCA

-

-

-

... More
ALUMINIUM BUS

-

-

-

... More
CURRENT DENSITY :- 0.8 AMP/1 SQ. MM.

-

-

-

... More
ALL CABLES- TOP CABLE ENTRIES

-

-

-

... More
All panels Switchgear will be provided with lockout tagout (LOTO)arrangement.

-

-

-

... More
INDICATIONS POSITION

-

-

-

... More
R/Y/B/ON/OFF/TRIP/SRV/DCH/TEST/SC/TCH INDICATION FOR ACB FEEDERS

-

-

-

... More
FOR ALL INCOMERS PHASE INDICATION WITH SWITCH POSITION.

-

-

-

... More
FOR ALL OUTGOINGS FOR SWITCH WITH SWITCH POSITION.

-

-

-

... More
PROTECTIONS:

-

-

-

... More
SINGLE PHASING PREVENTER ON INCOMING BUS FOR PHASE IN BALANCE AND SINGLE PHASE PREVENTIONS

-

-

-

... More
SURGE PROTECTION DEVICES

-

-

-

... More
METERING

-

-

-

... More
MFM as per SLD FOR INCOMING & OUTGOING FEEDER BREAKERS (WITH RS485 PORT SUITABLE FOR EMS & REMOTE MONITORING)

-

-

-

... More
ALL PROTECTION AND SENSING CTS SHOULD BE OF RESIN CAST TYPE

-

-

-

... More
MAIN DISTRIBUTION PANEL

1

-

-

... More
PANEL SHALL BE INDOOR TYPE AND AS PER IEC 61439, 1-2 LATEST STANDARDS. PANEL SHOULD BE SUPPLIED DIRECTLY FROM OEM'S ONLY I.E SUGGESTED MAKE ,LEGRAND,MITSUBHISHI, SCHNEIDER, ABB, L&T, SIEMENS ETC. BLOCKSET FOR SCHNEIDER AND NOT PRISMASET.

-

-

-

... More
PANEL SHOULD BE DESIGNED FOR 40 KA FAULT RATING

-

-

-

... More
25% VACANT COMPARTMENT PROVISION TO BE MADE FOR FUTURE LOAD EXPANSIONS.

-

-

-

... More
3 RESIN CAST CTS SHOULD BE PROVIDED FOR RTPFC IN MAIN PANEL SUGGESTED MAKE:- AE/NEWTEKE ETC.

-

-

-

... More
All below mentioned switchgears Qty Incoming & outgoing feeders must be considered for In each individual LT Panel.

-

-

-

... More
MAIN INCOMER

-

-

-

... More
2500 A FP ACB FOR INCOMER

-

-

-

... More
EDO TYPE MICROPROCESSOR BASED WITH LSIG PROTECTION.

-

-

-

... More
RACKING HANDLE, RACKING INTERLOCK, SAFTY SHUTTER, DOOR SEALING FRAME,READY TO CLOSED SHUNT TRIP COIL (230V), UNDER VOLTAGE COIL (415V), TRIP SIGNAL SWITCH, AUX. CONTACTS ( AS REQUIRED).

-

-

-

... More
KWH METER WITH RS485 PORT SUITABLE FOR EMS AND REMOTE MONITORNG (SUIBTALE CT'S WITH REQUIRED VA RATINGS SHOULD BE CONSIDERED) (SUIBTALE CT'S WITH REQUIRED VA RATINGS SHOULD BE CONSIDERED)

-

-

-

... More
OUTGOING

-

-

-

... More
800 A TP MCCB FOR 450 KVAR POWER FACTOR CORRECTION PANEL

-

-

-

... More
3 POLE MCCB LSIG PROTECTION WITH MICROPROCESSOR BASED RELEASE WITH ADJUSTABLE OVERLOAD & SHORT CKT PROTECTION

-

-

-

... More
800 A TP MCCB FOR UTILITY LOAD PANEL

-

-

-

... More
3 POLE MCCB LSIG PROTECTION WITH MICROPROCESSOR BASED RELEASE WITH ADJUSTABLE OVERLOAD & SHORT CKT PROTECTION

-

-

-

... More
KWH METER WITH RS485 PORT SUITABLE FOR EMS AND REMOTE MONITORNG (SUIBTALE CT'S WITH REQUIRED VA RATINGS SHOULD BE CONSIDERED)

-

-

-

... More
125 A TP MCCB FOR OFFICE BUILDING LOAD

-

-

-

... More
3 POLE MCCB LSIG PROTECTION WITH MICROPROCESSOR BASED RELEASE WITH ADJUSTABLE OVERLOAD & SHORT CKT PROTECTION

-

-

-

... More
KWH METER WITH RS485 PORT SUITABLE FOR EMS AND REMOTE MONITORNG (SUIBTALE CT'S WITH REQUIRED VA RATINGS SHOULD BE CONSIDERED)

-

-

-

... More
160 A TP MCCB FOR BONFIRE & DROP TEST FACILITY

-

-

-

... More
3 POLE MCCB LSIG PROTECTION WITH MICROPROCESSOR BASED RELEASE WITH ADJUSTABLE OVERLOAD & SHORT CKT PROTECTION

-

-

-

... More
KWH METER WITH RS485 PORT SUITABLE FOR EMS AND REMOTE MONITORNG (SUIBTALE CT'S WITH REQUIRED VA RATINGS SHOULD BE CONSIDERED)

-

-

-

... More
40 A TP MCCB FOR CORROSION CHAMBER FACILITY

-

-

-

... More
3 POLE MCCB LSIG PROTECTION WITH MICROPROCESSOR BASED RELEASE WITH ADJUSTABLE OVERLOAD & SHORT CKT PROTECTION

-

-

-

... More
KWH METER WITH RS485 PORT SUITABLE FOR EMS AND REMOTE MONITORNG (SUIBTALE CT'S WITH REQUIRED VA RATINGS SHOULD BE CONSIDERED)

-

-

-

... More
63 A TP MCCB FOR CYLINDER MATERIAL TEST FACILITY (VST + IMPACT & UTM MACHINES)

-

-

-

... More
3 POLE MCCB LSIG PROTECTION WITH MICROPROCESSOR BASED RELEASE WITH ADJUSTABLE OVERLOAD & SHORT CKT PROTECTION

-

-

-

... More
KWH METER WITH RS485 PORT SUITABLE FOR EMS AND REMOTE MONITORNG (SUIBTALE CT'S WITH REQUIRED VA RATINGS SHOULD BE CONSIDERED)

-

-

-

... More
125 A TP MCCB FOR TEMP. CYCLIC CHAMBER 01

-

-

-

... More
3 POLE MCCB LSIG PROTECTION WITH MICROPROCESSOR BASED RELEASE WITH ADJUSTABLE OVERLOAD & SHORT CKT PROTECTION

-

-

-

... More
KWH METER WITH RS485 PORT SUITABLE FOR EMS AND REMOTE MONITORNG (SUIBTALE CT'S WITH REQUIRED VA RATINGS SHOULD BE CONSIDERED)

-

-

-

... More
125 A TP MCCB FOR TEMP. CYCLIC CHAMBER 02

-

-

-

... More
3 POLE MCCB LSIG PROTECTION WITH MICROPROCESSOR BASED RELEASE WITH ADJUSTABLE OVERLOAD & SHORT CKT PROTECTION

-

-

-

... More
KWH METER WITH RS485 PORT SUITABLE FOR EMS AND REMOTE MONITORNG (SUIBTALE CT'S WITH REQUIRED VA RATINGS SHOULD BE CONSIDERED)

-

-

-

... More
200 A TP MCCB FOR HYD. CYCLIC PR. RIG 01

-

-

-

... More
3 POLE MCCB LSIG PROTECTION WITH MICROPROCESSOR BASED RELEASE WITH ADJUSTABLE OVERLOAD & SHORT CKT PROTECTION

-

-

-

... More
KWH METER WITH RS485 PORT SUITABLE FOR EMS AND REMOTE MONITORNG (SUIBTALE CT'S WITH REQUIRED VA RATINGS SHOULD BE CONSIDERED)

-

-

-

... More
200 A TP MCCB FOR HYD. CYCLIC PR. RIG 02

-

-

-

... More
3 POLE MCCB LSIG PROTECTION WITH MICROPROCESSOR BASED RELEASE WITH ADJUSTABLE OVERLOAD & SHORT CKT PROTECTION

-

-

-

... More
KWH METER WITH RS485 PORT SUITABLE FOR EMS AND REMOTE MONITORNG (SUIBTALE CT'S WITH REQUIRED VA RATINGS SHOULD BE CONSIDERED)

-

-

-

... More
125 A TP MCCB FOR HYD VOL EXP + HYD. BURST RIG + ULTRASONIC M/C + CONTROL RM

-

-

-

... More
3 POLE MCCB LSIG PROTECTION WITH MICROPROCESSOR BASED RELEASE WITH ADJUSTABLE OVERLOAD & SHORT CKT PROTECTION

-

-

-

... More
KWH METER WITH RS485 PORT SUITABLE FOR EMS AND REMOTE MONITORNG (SUIBTALE CT'S WITH REQUIRED VA RATINGS SHOULD BE CONSIDERED)

-

-

-

... More
160 A TP MCCB FOR NATURAL GAS PRESSURE CYCLIC TEST RIG SECTION LOAD

-

-

-

... More
3 POLE MCCB LSIG PROTECTION WITH MICROPROCESSOR BASED RELEASE WITH ADJUSTABLE OVERLOAD & SHORT CKT PROTECTION

-

-

-

... More
KWH METER WITH RS485 PORT SUITABLE FOR EMS AND REMOTE MONITORNG (SUIBTALE CT'S WITH REQUIRED VA RATINGS SHOULD BE CONSIDERED)

-

-

-

... More
160 A TP MCCB FOR NATURAL GAS PERMEATION TEST RIG SECTION LOAD

-

-

-

... More
3 POLE MCCB LSIG PROTECTION WITH MICROPROCESSOR BASED RELEASE WITH ADJUSTABLE OVERLOAD & SHORT CKT PROTECTION

-

-

-

... More
KWH METER WITH RS485 PORT SUITABLE FOR EMS AND REMOTE MONITORNG (SUIBTALE CT'S WITH REQUIRED VA RATINGS SHOULD BE CONSIDERED)

-

-

-

... More
125 A TP MCCB FOR CYLINDER PREPARATION AREA

-

-

-

... More
3 POLE MCCB LSIG PROTECTION WITH MICROPROCESSOR BASED RELEASE WITH ADJUSTABLE OVERLOAD & SHORT CKT PROTECTION

-

-

-

... More
KWH METER WITH RS485 PORT SUITABLE FOR EMS AND REMOTE MONITORNG (SUIBTALE CT'S WITH REQUIRED VA RATINGS SHOULD BE CONSIDERED)

-

-

-

... More
63 A TP MCCB FOR DEGASSING AREA

-

-

-

... More
3 POLE MCCB LSIG PROTECTION WITH MICROPROCESSOR BASED RELEASE WITH ADJUSTABLE OVERLOAD & SHORT CKT PROTECTION

-

-

-

... More
KWH METER WITH RS485 PORT SUITABLE FOR EMS AND REMOTE MONITORNG (SUIBTALE CT'S WITH REQUIRED VA RATINGS SHOULD BE CONSIDERED)

-

-

-

... More
800 A TP MCCB FOR SPARE

-

-

-

... More
3 POLE MCCB LSIG PROTECTION WITH MICROPROCESSOR BASED RELEASE WITH ADJUSTABLE OVERLOAD & SHORT CKT PROTECTION

-

-

-

... More
200 A TP MCCB FOR SPARE

-

-

-

... More
3 POLE MCCB LSIG PROTECTION WITH MICROPROCESSOR BASED RELEASE WITH ADJUSTABLE OVERLOAD & SHORT CKT PROTECTION

-

-

-

... More
160 A TP MCCB FOR SPARE

-

-

-

... More
3 POLE MCCB LSIG PROTECTION WITH MICROPROCESSOR BASED RELEASE WITH ADJUSTABLE OVERLOAD & SHORT CKT PROTECTION

-

-

-

... More
125 A TP MCCB FOR SPARE

-

-

-

... More
3 POLE MCCB LSIG PROTECTION WITH MICROPROCESSOR BASED RELEASE WITH ADJUSTABLE OVERLOAD & SHORT CKT PROTECTION

-

-

-

... More
40 A TP MCCB FOR SPARE

-

-

-

... More
3 POLE MCCB LSIG PROTECTION WITH MICROPROCESSOR BASED RELEASE WITH ADJUSTABLE OVERLOAD & SHORT CKT PROTECTION

-

-

-

... More
UTILITY LOAD DISTRIBUTION PANEL

1

-

-

... More
PANEL SHALL BE INDOOR TYPE AND AS PER IEC 61439, 1-2 LATEST STANDARDS. PANEL SHOULD BE SUPPLIED DIRECTLY FROM OEM'S ONLY I.E SCHNEIDER, ABB, L&T, SIEMENS ETC. BLOCKSET FOR SCHNEIDER AND NOT PRISMASET.

-

-

-

... More
PANEL SHOULD BE DESIGNED FOR 25 KA FAULT RATING

-

-

-

... More
All below mentioned switchgears Qty Incoming & outgoing feeders must be considered for In each individual LT Panel.

-

-

-

... More
MAIN INCOMER

-

-

-

... More
800 A TP MCCB FOR UTILITY LOAD PANEL

-

-

-

... More
3 POLE MCCB LSIG PROTECTION WITH MICROPROCESSOR BASED RELEASE WITH ADJUSTABLE OVERLOAD & SHORT CKT PROTECTION

-

-

-

... More
OUTGOING

-

-

-

... More
160 A TP MCCB FOR COMPRESSOR 01

-

-

-

... More
3 POLE MCCB LSIG PROTECTION WITH MICROPROCESSOR BASED RELEASE WITH ADJUSTABLE OVERLOAD & SHORT CKT PROTECTION

-

-

-

... More
160 A TP MCCB FOR COMPRESSOR 02

-

-

-

... More
3 POLE MCCB LSIG PROTECTION WITH MICROPROCESSOR BASED RELEASE WITH ADJUSTABLE OVERLOAD & SHORT CKT PROTECTION

-

-

-

... More
160 A TP MCCB FOR COMPRESSOR 03

-

-

-

... More
3 POLE MCCB LSIG PROTECTION WITH MICROPROCESSOR BASED RELEASE WITH ADJUSTABLE OVERLOAD & SHORT CKT PROTECTION

-

-

-

... More
160 A TP MCCB FOR AUXILLARY DB 01

-

-

-

... More
3 POLE MCCB LSIG PROTECTION WITH MICROPROCESSOR BASED RELEASE WITH ADJUSTABLE OVERLOAD & SHORT CKT PROTECTION

-

-

-

... More
160 A TP MCCB FOR AUXILLARY DB 02

-

-

-

... More
3 POLE MCCB LSIG PROTECTION WITH MICROPROCESSOR BASED RELEASE WITH ADJUSTABLE OVERLOAD & SHORT CKT PROTECTION

-

-

-

... More
80 A TP MCCB FOR AC OUTDOOR UNIT

-

-

-

... More
3 POLE MCCB LSIG PROTECTION WITH MICROPROCESSOR BASED RELEASE WITH ADJUSTABLE OVERLOAD & SHORT CKT PROTECTION

-

-

-

... More
63 A TP MCCB FOR 10T CRANE

-

-

-

... More
3 POLE MCCB LSIG PROTECTION WITH MICROPROCESSOR BASED RELEASE WITH ADJUSTABLE OVERLOAD & SHORT CKT PROTECTION

-

-

-

... More
63 A TP MCCB FOR AIR WASHER SYSTEM

-

-

-

... More
3 POLE MCCB LSIG PROTECTION WITH MICROPROCESSOR BASED RELEASE WITH ADJUSTABLE OVERLOAD & SHORT CKT PROTECTION

-

-

-

... More
63 A TP MCCB FOR ETP PLANT

-

-

-

... More
3 POLE MCCB LSIG PROTECTION WITH MICROPROCESSOR BASED RELEASE WITH ADJUSTABLE OVERLOAD & SHORT CKT PROTECTION

-

-

-

... More
100 A TP MCCB FOR VENTILATION SYSTEM

-

-

-

... More
3 POLE MCCB LSIG PROTECTION WITH MICROPROCESSOR BASED RELEASE WITH ADJUSTABLE OVERLOAD & SHORT CKT PROTECTION

-

-

-

... More
160 A TP MCCB FOR SHED LIGHTING & RAW POWER LOADS

-

-

-

... More
3 POLE MCCB LSIG PROTECTION WITH MICROPROCESSOR BASED RELEASE WITH ADJUSTABLE OVERLOAD & SHORT CKT PROTECTION

-

-

-

... More
125 A TP MCCB FOR 40 + 40 KVA UPS LOAD

-

-

-

... More
3 POLE MCCB LSIG PROTECTION WITH MICROPROCESSOR BASED RELEASE WITH ADJUSTABLE OVERLOAD & SHORT CKT PROTECTION

-

-

-

... More
160 A TP MCCB FOR SPARE

-

-

-

... More
3 POLE MCCB LSIG PROTECTION WITH MICROPROCESSOR BASED RELEASE WITH ADJUSTABLE OVERLOAD & SHORT CKT PROTECTION

-

-

-

... More
125 A TP MCCB FOR SPARE

-

-

-

... More
3 POLE MCCB LSIG PROTECTION WITH MICROPROCESSOR BASED RELEASE WITH ADJUSTABLE OVERLOAD & SHORT CKT PROTECTION

-

-

-

... More
63 A TP MCCB FOR SPARE

-

-

-

... More
3 POLE MCCB LSIG PROTECTION WITH MICROPROCESSOR BASED RELEASE WITH ADJUSTABLE OVERLOAD & SHORT CKT PROTECTION

-

-

-

... More
63 A TP MCCB FOR SPARE

-

-

-

... More
3 POLE MCCB LSIG PROTECTION WITH MICROPROCESSOR BASED RELEASE WITH ADJUSTABLE OVERLOAD & SHORT CKT PROTECTION

-

-

-

... More
25 A TP MCCB FOR SPARE

-

-

-

... More
3 POLE MCCB LSIG PROTECTION WITH MICROPROCESSOR BASED RELEASE WITH ADJUSTABLE OVERLOAD & SHORT CKT PROTECTION

-

-

-

... More
LIGHTING & RAW POWER DISTRIBUTION PANEL

1

-

-

... More
PANEL SHOULD BE WALL MOUNTED

-

-

-

... More
PANEL SHOULD BE DESIGNED FOR 10 KA FAULT RATING

-

-

-

... More
All below mentioned switchgears Qty Incoming & outgoing feeders must be considered for In each individual LT Panel.

-

-

-

... More
MAIN INCOMER

-

-

-

... More
160 A TP MCCB FOR SHED LIGHTING & RAW POWER LOADS

-

-

-

... More
3 POLE MCCB LSIG PROTECTION WITH MICROPROCESSOR BASED RELEASE WITH ADJUSTABLE OVERLOAD & SHORT CKT PROTECTION

-

-

-

... More
OUTGOING

-

-

-

... More
40 A TP MCB FOR RAW POWER DB, C CURVE 10 KA

-

-

-

... More
10 A TP MCB FOR HVLS 01, C CURVE 10 KA

-

-

-

... More
10 A TP MCB FOR HVLS 02, C CURVE 10 KA

-

-

-

... More
10 A TP MCB FOR HVLS 03, C CURVE 10 KA

-

-

-

... More
40 A DP MCB FOR LIGHTING DB 01, C CURVE 10 KA

-

-

-

... More
40 A DP MCB FOR LIGHTING DB 02, C CURVE 10 KA

-

-

-

... More
40 A DP MCB FOR LIGHTING DB 03, C CURVE 10 KA

-

-

-

... More
40 A TP MCB FOR SPARE, C CURVE 10 KA

-

-

-

... More
10 A TP MCB FOR SPARE, C CURVE 10 KA

-

-

-

... More
40 A DP MCB FOR SPARE, C CURVE 10 KA

-

-

-

... More
EXTERNAL AREA LIGHTING COMPARTMENT

-

-

-

... More
SUBINCOMER

-

-

-

... More
32 A TP MCCB FOR SPARE

-

-

-

... More
3 POLE MCCB LSIG PROTECTION WITH MICROPROCESSOR BASED RELEASE WITH ADJUSTABLE OVERLOAD & SHORT CKT PROTECTION

-

-

-

... More
AC3 CONTACTOR IN SERIES FOR AUTO ON & OFF OPERATION

-

-

-

... More
ASTRONOMICAL TIMER WITH AUTO & MANUAL OPERATION

-

-

-

... More
SPP & SPD IN PROTECTION

-

-

-

... More
OUTGOINGS OF SUBINCOMER

-

-

-

... More
16 A TP MCB FOR HIGH MAST 01

-

-

-

... More
16 A TP MCB FOR HIGH MAST 02

-

-

-

... More
16 A TP MCB FOR HIGH MAST 03

-

-

-

... More
16 A TP MCB FOR SPARE

-

-

-

... More
16 A DP MCB FOR FLOODLIGHTING CKT. 01

-

-

-

... More
16 A DP MCB FOR FLOODLIGHTING CKT. 02

-

-

-

... More
16 A DP MCB FOR SPARE

-

-

-

... More
LOCAL ISOLATOR PANELS (MCCB)

-

-

-

... More
PANEL SHALL BE INDOOR TYPE WITH STAND OF 900 MM HIGH. PANEL BOX SHOULD HAVE EARTHING TERMINAL TO CONNECT EARTHING STRIP

-

-

-

... More
ALL LOCAL ISOLATORS SHOULD BE SUITABLE FOR IP 42 RATING (INDOOR APPLICATION)

-

-

-

... More
PANEL CONTENTS

-

-

-

... More
SWITCH POSITION INDICATION

-

-

-

... More
DOOR INTERLOCK

-

-

-

... More
SURGE PROTECTION DEVICE

-

-

-

... More
125 A TP MCCB FOR TEMP. CYCLIC CHAMBER 01

1

-

-

... More
125 A TP MCCB FOR TEMP. CYCLIC CHAMBER 02

1

-

-

... More
200 A TP MCCB FOR HYD. CYCLIC PR. RIG 01

1

-

-

... More
200 A TP MCCB FOR HYD. CYCLIC PR. RIG 02

1

-

-

... More
160 A TP MCCB FOR NATURAL GAS PRESSURE CYCLIC TEST RIG SECTION LOAD

1

-

-

... More
160 A TP MCCB FOR NATURAL GAS PERMEATION TEST RIG SECTION LOAD

1

-

-

... More
125 A FP MCCB FOR 2 NOS. OF 40 KVA UPS (IN PARALLEL OPERATION)

1

-

-

... More
BONFIRE & DROP TEST FACILITY PANEL

1

-

-

... More
PANEL SHOULD BE WALL MOUNTED

-

-

-

... More
PANEL SHOULD BE DESIGNED FOR 10 KA FAULT RATING

-

-

-

... More
PHASE AND SWITCH POSITION INDICATION LAMP FOR INCOMER

-

-

-

... More
KWH METER WITH RS485 PORT SUITABLE FOR EMS AND REMOTE MONITORNG (SUIBTALE CT'S WITH REQUIRED VA RATINGS SHOULD BE CONSIDERED)

-

-

-

... More
MAIN INCOMER

-

-

-

... More
160 A TP MCCB FOR BONFIRE & DROP TEST FACILITY

-

-

-

... More
3 POLE MCCB LSIG PROTECTION WITH MICROPROCESSOR BASED RELEASE WITH ADJUSTABLE OVERLOAD & SHORT CKT PROTECTION

-

-

-

... More
OUTGOING

-

-

-

... More
63 A TP MCB FOR AIR WASHER, C CURVE 10 KA

-

-

-

... More
63 A TP MCB FOR CRANE, C CURVE 10 KA

-

-

-

... More
32 A TP MCB FOR DROP RIG, C CURVE 10 KA

-

-

-

... More
16 A TP MCB FOR BONFIRE SYSTEM, C CURVE 10 KA

-

-

-

... More
32 A TP MCB FOR BONFIRE SYSTEM, C CURVE 10 KA

-

-

-

... More
32 A DP MCB FOR LIGHTING DB, C CURVE 10 KA

-

-

-

... More
32 A DP MCB FOR SPARE, C CURVE 10 KA

-

-

-

... More
63 A TP MCB FOR SPARE, C CURVE 10 KA

-

-

-

... More
16 A TP MCB FOR SPARE, C CURVE 10 KA

-

-

-

... More
UPS DISTRIBUTION PANEL

1

-

-

... More
PANEL SHOULD BE WALL MOUNTED

-

-

-

... More
PANEL SHOULD BE DESIGNED FOR 10 KA FAULT RATING

-

-

-

... More
MAIN INCOMER

-

-

-

... More
125 A TP MCCB FOR 40 + 40 KVA UPS LOAD

-

-

-

... More
3 POLE MCCB LSIG PROTECTION WITH MICROPROCESSOR BASED RELEASE WITH ADJUSTABLE OVERLOAD & SHORT CKT PROTECTION

-

-

-

... More
OUTGOING

-

-

-

... More
40 A TP MCB FOR SHED UPS DISTRIBUTION DB 01, C CURVE 10 KA

-

-

-

... More
40 A TP MCB FOR SHED UPS DISTRIBUTION DB 02, C CURVE 10 KA

-

-

-

... More
25 A TP MCB FOR BONFIRE & DROP FACILITY UNIT, C CURVE 10 KA

-

-

-

... More
25 A TP MCB FOR OFFICE AREA UPS LOAD DISTRIBUTION, C CURVE 10 KA

-

-

-

... More
40 A TP MCB FOR SPARE , C CURVE 10 KA

-

-

-

... More
25 A TP MCB FOR SPARE , C CURVE 10 KA

-

-

-

... More
450 KVAR (EFFECTIVE @ 415V) REAL TIME POWER FACTOR CORRECTION PANEL

1

-

-

... More
PANEL SHOULD HAVE GAS FLOODING SYSTEM.

-

-

-

... More
INCOMER

-

-

-

... More
800 A TP MCCB FOR 450 KVAR POWER FACTOR CORRECTION PANEL

-

-

-

... More
3 POLE MCCB LSIG PROTECTION WITH MICROPROCESSOR BASED RELEASE WITH ADJUSTABLE OVERLOAD & SHORT CKT PROTECTION

-

-

-

... More
OUTGOING

-

-

-

... More
The RTPFC Relay with 3 CT Sesing

-

-

-

... More
The Switching of Capacitors should be done with the Thyristors.

-

-

-

... More
"APP" Type Capacitors should be used. With suitable voltage (480 volts)

-

-

-

... More
7 % Detuned Reactors should added in a circuit to neutralise the Harmonics generated in a circuit

-

-

-

... More
Select Stages in such a way that the Minimum Stage should be 5 kVAR and Maximum should be of 100 kVAR (Preferable stages will be 8 Stages)

-

-

-

... More
Adequoate Ventilation should be arranged while designing the General Arrangement of Panel. Proper Lowers and Exhaust fans of required CFM should be used.

-

-

-

... More
TOTAL OF SECTION PANELS

-

-

-

... More
READYMADE DISTRIBUTION BOARD

-

-

-

... More
Supply, installation, testing, tagging, (Circuit numbering) and commissioning of following double door readymade recessed type MCB, DB, fabricated out of CRCA sheet and painted with powdercoating process OR made out of scratch proof polycarbonate body, and concealed in wall or on surface with necessary frame complete as required. DB's should be, - IP42 RATED - Double Door - Powder coated metal doors and enclosure - Phase copper bus bars, Neutral and earth bar with tapped holes, - Necessary cable boxes for incoming / outgoing conduits and cables. - 1/3 phase distribution Suitable for Flush and surface mounted - DB's shall be as per IEC 61439-3.

-

-

-

... More
SHED LIGHTING DB (LDB 01 - 04)

4

-

-

... More
12 WAY SPN MCB DB

-

-

-

... More
INCOMER

-

-

-

... More
40 A DP RCCB, 100 MA SENSITIVITY

-

-

-

... More
OUTGOING

-

-

-

... More
10 A SP MCB, 10 KA C CURVE - 08 NOS

-

-

-

... More
SHED EMERGENCY LIGHTING DB (ELDB 01 - 03)

3

-

-

... More
08 WAY SPN MCB DB

-

-

-

... More
INCOMER

-

-

-

... More
16 A DP RCCB, 100 MA SENSITIVITY

-

-

-

... More
OUTGOING

-

-

-

... More
10 A SP MCB, 10 KA C CURVE - 04 NOS

-

-

-

... More
AUXILLARY SUPPLY DB'S

2

-

-

... More
12 WAY DPX MCCB DB

-

-

-

... More
INCOMER

-

-

-

... More
160 A TP MCCB, 16 KA

-

-

-

... More
OUTGOING

-

-

-

... More
32 A TP MCB, 10 KA C CURVE - 10 NOS.

-

-

-

... More
CYLINDER MATERIAL TEST SET UP DB

1

-

-

... More
06 WAY VTPN MCB DB

-

-

-

... More
INCOMER

-

-

-

... More
63 A TP MCB, 10 KA C CURVE

-

-

-

... More
OUTGOING

-

-

-

... More
32 A TP MCB, 10 KA C CURVE FOR VST

-

-

-

... More
16 A TP MCB, 10 KA C CURVE FOR IMPACT RIG

-

-

-

... More
16 A TP MCB, 10 KA C CURVE FOR UTM (600KN)

-

-

-

... More
32 A TP MCB, 10 KA C CURVE FOR UTM (50KN)

-

-

-

... More
32 A TP MCB FOR SPARE

-

-

-

... More
HYD RIG, ULTRASONIC MACHINE & CONTROL ROOM

1

-

-

... More
04 WAY DPX MCCB DB

-

-

-

... More
INCOMER

-

-

-

... More
125 A TP MCCB FOR HYD VOL EXP + HYD. BURST RIG + ULTRASONIC M/C + CONTROL RM

-

-

-

... More
OUTGOING

-

-

-

... More
32 A SP MCB, 10 KA C CURVE FOR HYDROSTATIC BURST RIG

-

-

-

... More
32 A SP MCB, 10 KA C CURVE FOR HYDRAULIC VOLUME EXPANSION RIG

-

-

-

... More
32 A SP MCB, 10 KA C CURVE FOR CONTROL ROOM

-

-

-

... More
63 A TP MCB, 10 KA C CURVE FOR ULTRASONIC MACHINE

-

-

-

... More
63 A TP MCB, 10 KA C CURVE FOR SPARE

-

-

-

... More
32 A SP MCB, 10 KA C CURVE FOR SPARE

-

-

-

... More
OFFICE BUILDING LOAD DB

1

-

-

... More
04 WAY DPX MCCB DB

-

-

-

... More
INCOMER

-

-

-

... More
125 A TP MCCB FOR OFFICE BUILDING LOAD

-

-

-

... More
OUTGOING

-

-

-

... More
40 A TP MCB, 10 KA C CURVE FOR LIGHTING & RAW POWER DB

-

-

-

... More
63 A TP MCB, 10 KA C CURVE FOR OUTDOOR UNIT

-

-

-

... More
40 A TP MCB, 10 KA C CURVE FOR SPARE

-

-

-

... More
40 A TP MCB, 10 KA C CURVE FOR SPARE

-

-

-

... More
OFFICE AREA LIGHTING & RAW POWER DB

1

-

-

... More
06 WAY VTPN MCB DB

-

-

-

... More
INCOMER

-

-

-

... More
40 A TP MCB, 10 KA C CURVE FOR LIGHTING & RAW POWER DB

-

-

-

... More
OUTGOING

-

-

-

... More
16 A SP MCB, 10 KA C CURVE FOR LIGHTING CKT 01

-

-

-

... More
16 A SP MCB, 10 KA C CURVE FOR LIGHTING CKT 02

-

-

-

... More
16 A SP MCB, 10 KA C CURVE FOR LIGHTING CKT 03

-

-

-

... More
25 A SP MCB, 10 KA C CURVE FOR RAW POWER CKT. 01

-

-

-

... More
25 A SP MCB, 10 KA C CURVE FOR RAW POWER CKT. 02

-

-

-

... More
25 A SP MCB, 10 KA C CURVE FOR RAW POWER CKT. 03

-

-

-

... More
25 A SP MCB, 10 KA C CURVE FOR RAW POWER CKT. 04

-

-

-

... More
16 A SP MCB, 10 KA C CURVE FOR CASSETTE SUPPLY CKT. 01

-

-

-

... More
16 A SP MCB, 10 KA C CURVE FOR CASSETTE SUPPLY CKT. 02

-

-

-

... More
16 A SP MCB, 10 KA C CURVE FOR CASSETTE SUPPLY CKT. 03

-

-

-

... More
16 A SP MCB, 10 KA C CURVE FOR SPARE

-

-

-

... More
16 A SP MCB, 10 KA C CURVE FOR SPARE

-

-

-

... More
25 A SP MCB, 10 KA C CURVE FOR SPARE

-

-

-

... More
25 A SP MCB, 10 KA C CURVE FOR SPARE

-

-

-

... More
BONFIRE FACILITY UPS LOAD

1

-

-

... More
12 WAY SPN MCB DB

-

-

-

... More
INCOMER

-

-

-

... More
25 A TP MCB FOR BONFIRE & DROP FACILITY UNIT, C CURVE 10 KA

-

-

-

... More
OUTGOING

-

-

-

... More
20 A SP MCB, 10 KA C CURVE FOR UPS CKT. 01

-

-

-

... More
20 A SP MCB, 10 KA C CURVE FOR UPS CKT. 01

-

-

-

... More
20 A SP MCB, 10 KA C CURVE FOR UPS CKT. 01

-

-

-

... More
25 A SP MCB, 10 KA C CURVE FOR SERVER / NETWORK RACK SUPPLY

-

-

-

... More
25 A SP MCB, 10 KA C CURVE FOR SPARE

-

-

-

... More
25 A SP MCB, 10 KA C CURVE FOR SPARE

-

-

-

... More
OFFICE AREA UPS POWER DB

1

-

-

... More
12 WAY SPN MCB DB

-

-

-

... More
INCOMER

-

-

-

... More
25 A TP MCB FOR OFFICE AREA UPS LOAD DISTRIBUTION, C CURVE 10 KA

-

-

-

... More
OUTGOING

-

-

-

... More
25 A SP MCB, 10 KA C CURVE FOR UPS CKT. 01

-

-

-

... More
25 A SP MCB, 10 KA C CURVE FOR UPS CKT. 02

-

-

-

... More
25 A SP MCB, 10 KA C CURVE FOR UPS CKT. 03

-

-

-

... More
25 A SP MCB, 10 KA C CURVE FOR SERVER / NETWORK RACK SUPPLY

-

-

-

... More
25 A SP MCB, 10 KA C CURVE FOR SPARE

-

-

-

... More
25 A SP MCB, 10 KA C CURVE FOR SPARE

-

-

-

... More
SHED AREA RAW POWER DB

1

-

-

... More
04 WAY VTPN MCB DB

-

-

-

... More
INCOMER

-

-

-

... More
40 A TP MCB FOR RAW POWER DB, C CURVE 10 KA

-

-

-

... More
OUTGOING

-

-

-

... More
25 A SP MCB, 10 KA C CURVE FOR RAW POWER CKT 01

-

-

-

... More
25 A SP MCB, 10 KA C CURVE FOR RAW POWER CKT 02

-

-

-

... More
25 A SP MCB, 10 KA C CURVE FOR RAW POWER CKT 03

-

-

-

... More
25 A SP MCB, 10 KA C CURVE FOR RAW POWER CKT 04

-

-

-

... More
25 A SP MCB, 10 KA C CURVE FOR RAW POWER CKT. 05

-

-

-

... More
25 A SP MCB, 10 KA C CURVE FOR RAW POWER CKT. 06

-

-

-

... More
25 A SP MCB, 10 KA C CURVE FOR RAW POWER CKT. 07

-

-

-

... More
25 A SP MCB, 10 KA C CURVE FOR SPARE

-

-

-

... More
25 A SP MCB, 10 KA C CURVE FOR SPARE

-

-

-

... More
25 A SP MCB, 10 KA C CURVE FOR SPARE

-

-

-

... More
25 A SP MCB, 10 KA C CURVE FOR SPARE

-

-

-

... More
MCB ENCLOSURE WITH MCB

-

-

-

... More
4 MODULE DB BOX POWDER COATED

-

-

-

... More
40 A FP MCB, C CURVE 10 KA FOR CORROSION CHAMBER FACILITY

1

-

-

... More
2 MODULE DB BOX POWDER COATED

-

-

-

... More
16 A SP MCB, C CURVE 10 KA FOR CANOPY LIGHT CONTROL

2

-

-

... More
16 A SP MCB, C CURVE 10 KA FOR BELOW MEZZANINE LIGHTING

2

-

-

... More
16 A SP MCB, C CURVE 10 KA FOR TOILET

1

-

-

... More
AIR CIRCULATORS

3

-

-

... More
2 MODULE DB BOX WITH 4 CORE 2.5 SQ.MM CU AR. CABLE LOOP IN LOOP OUT PROVISION

-

-

-

... More
INCOMER

-

-

-

... More
10 A SP MCB, C CURVE 10 KA

-

-

-

... More
Supply & installation of 100mm x 100mm x 50mm deep 16 SWG M.S. poweder coated junction box with 14 SWG cover with 4 way 15 connector.( for storge shed lighting )

62

-

-

... More
Supply, fixing, testing, of good quality industrial sockets with MCB's or ELCB of different ratings in readymade IP 20 metal enclosure. Box should be suitable to terminate cables / wires easily, complete as required.

-

-

-

... More
32A TP MCB INCOMER with 32A 3Ø, 3P+N+E, + 16A 1Ø, P+N+E, SocketSocket (with Interlock) 16A SPMCB in a Readymade Box. (Auxillary Sockets)

15

-

-

... More
63A TP MCB INCOMER with 63A 3Ø, 3P+N+E, + 25A 1Ø, P+N+E, SocketSocket (with Interlock) 25A SPMCB in a Readymade Box. (Auxillary Sockets)

-

-

-

... More
TOTAL OF SECTION READYMADE DISTRIBUTION BOARD

-

-

-

... More
CABLES AND END TERMINATION

-

-

-

... More
Supply, testing, tagging, laying and commissioning following sizes of 1100 Volt grade, XLPE / PVC insulated multistrand Al. / Cu. Conductor armoured / unarmoured cables (As Per IS 1554 & IS 7098) in readymade RCC trench, in provided PVC pipe, RCC pipe hume pipe, on cable trays / ladders etc. as. required complete with clamps for fixing tagging etc.

-

-

-

... More
3.5 CORE 400 SQ. MM AL XLPE ARM CABLE

-

-

-

... More
3.5 CORE 300 SQ. MM AL XLPE ARM CABLE

1863

-

-

... More
3.5 CORE 240 SQ. MM AL XLPE ARM CABLE

-

-

-

... More
3.5 CORE 185 SQ. MM AL XLPE ARM CABLE

121

-

-

... More
3.5 CORE 150 SQ. MM AL XLPE ARM CABLE

150

-

-

... More
3.5 CORE 120 SQ. MM AL XLPE ARM CABLE

460

-

-

... More
3.5 CORE 95 SQ. MM AL XLPE ARM CABLE

414

-

-

... More
3.5 CORE 70 SQ. MM AL XLPE ARM CABLE

167

-

-

... More
3.5 CORE 50 SQ. MM AL XLPE ARM CABLE

-

-

-

... More
3.5 CORE 35 SQ. MM AL XLPE ARM CABLE

-

-

-

... More
4 CORE 25 SQ. MM AL XLPE ARM CABLE

-

-

-

... More
4 CORE 16 SQ. MM AL XLPE ARM CABLE

64

-

-

... More
4 CORE 10 SQ. MM CU XLPE ARM CABLE

512

-

-

... More
4 CORE 6 SQ. MM CU XLPE ARM CABLE

879

-

-

... More
4 CORE 4 SQ. MM CU XLPE ARM CABLE

754

-

-

... More
4 CORE 2.5 SQ. MM CU XLPE ARM CABLE

230

-

-

... More
3 CORE 6 SQ. MM CU PVC ARM CABLE

29

-

-

... More
3 CORE 4 SQ. MM CU PVC ARM CABLE

299

-

-

... More
3 CORE 2.5 SQ. MM CU PVC ARM CABLE

1058

-

-

... More
3 CORE 1.5 SQ. MM CU PVC ARM CABLE

-

-

-

... More
4 CORE 25 SQ. MM CU FLEXIBLE CABLE

-

-

-

... More
4 CORE 16 SQ. MM CU FLEXIBLE CABLE

-

-

-

... More
4 CORE 6 SQ. MM CU FLEXIBLE CABLE

-

-

-

... More
4 CORE 4 SQ. MM CU FLEXIBLE CABLE

-

-

-

... More
4 CORE 2.5 SQ. MM CU FLEXIBLE CABLE

-

-

-

... More
3 CORE 4 SQ. MM CU FLEXIBLE CABLE

-

-

-

... More
3 CORE 2.5 SQ. MM CU FLEXIBLE CABLE

-

-

-

... More
3 CORE 1.5 SQ. MM CU FLEXIBLE CABLE

-

-

-

... More
1 CORE 25 SQ. MM CU FLEXIBLE CABLE.

-

-

-

... More
1 CORE 10 SQ. MM CU FLEXIBLE CABLE.

-

-

-

... More
3.5 CORE 70 SQ. MM CU UNARMOURED CABLE

-

-

-

... More
3.5 CORE 50 SQ. MM CU UNARMOURED CABLE

-

-

-

... More
16 CORE 2.5 SQ. MM CU XLPE ARM CABLE

-

-

-

... More
Supply and providing LV cable end termination for below listed cable with Aluminum/copper/bimetallic lugs as required , flange type brass cable glands (Double compression type), PVC glands for flexible cables with tapping, crimping, etc.

-

-

-

... More
3.5 CORE 400 SQ. MM AL XLPE ARM CABLE

-

-

-

... More
3.5 CORE 300 SQ. MM AL XLPE ARM CABLE

18

-

-

... More
3.5 CORE 240 SQ. MM AL XLPE ARM CABLE

-

-

-

... More
3.5 CORE 185 SQ. MM AL XLPE ARM CABLE

18

-

-

... More
3.5 CORE 150 SQ. MM AL XLPE ARM CABLE

4

-

-

... More
3.5 CORE 120 SQ. MM AL XLPE ARM CABLE

6

-

-

... More
3.5 CORE 95 SQ. MM AL XLPE ARM CABLE

22

-

-

... More
3.5 CORE 70 SQ. MM AL XLPE ARM CABLE

6

-

-

... More
3.5 CORE 50 SQ. MM AL XLPE ARM CABLE

-

-

-

... More
3.5 CORE 35 SQ. MM AL XLPE ARM CABLE

-

-

-

... More
4 CORE 25 SQ. MM AL XLPE ARM CABLE

-

-

-

... More
4 CORE 16 SQ. MM AL XLPE ARM CABLE

2

-

-

... More
4 CORE 10 SQ. MM CU XLPE ARM CABLE

22

-

-

... More
4 CORE 6 SQ. MM CU XLPE ARM CABLE

40

-

-

... More
4 CORE 4 SQ. MM CU XLPE ARM CABLE

16

-

-

... More
4 CORE 2.5 SQ. MM CU XLPE ARM CABLE

12

-

-

... More
3 CORE 4 SQ. MM CU PVC ARM CABLE

12

-

-

... More
3 CORE 2.5 SQ. MM CU PVC ARM CABLE

116

-

-

... More
3 CORE 1.5 SQ. MM CU PVC ARM CABLE

-

-

-

... More
4 CORE 25 SQ. MM CU FLEXIBLE CABLE

-

-

-

... More
4 CORE 16 SQ. MM CU FLEXIBLE CABLE

-

-

-

... More
4 CORE 6 SQ. MM CU FLEXIBLE CABLE

-

-

-

... More
4 CORE 4 SQ. MM CU FLEXIBLE CABLE

-

-

-

... More
4 CORE 2.5 SQ. MM CU FLEXIBLE CABLE

-

-

-

... More
3 CORE 6 SQ. MM CU PVC ARM CABLE

-

-

-

... More
3 CORE 4 SQ. MM CU FLEXIBLE CABLE

-

-

-

... More
3 CORE 2.5 SQ. MM CU FLEXIBLE CABLE

-

-

-

... More
3 CORE 1.5 SQ. MM CU FLEXIBLE CABLE

-

-

-

... More
1 CORE 25 SQ. MM CU FLEXIBLE CABLE.

-

-

-

... More
1 CORE 10 SQ. MM CU FLEXIBLE CABLE.

-

-

-

... More
3.5 CORE 70 SQ. MM CU UNARMOURED CABLE

-

-

-

... More
3.5 CORE 50 SQ. MM CU UNARMOURED CABLE

-

-

-

... More
16 CORE 2.5 SQ. MM CU XLPE ARM CABLE

-

-

-

... More
TOTAL OF SECTION CABLES AND END TERMINATION

-

-

-

... More
CABLE TRAY

-

-

-

... More
Supply, Providing and fixing of perforated /ladder Cable tray with horizontal & vertical Bends, reducers, Tee's, cross over member and other accessories as required and supporting system for suspension from ceiling & fixing at walls/coloumn with Hot Dip Galvanized Armstruct type. The tray shall be made of minimum 1.5 mm thick sheet steel hot dip galvanised. (Rate shall be inclusive of cost for primary & secondary supporting arrangement as per standards, site conditions and Connection of 10 sqmm copper flexible wire to earth terminals at coupling of cable trays ).

-

-

-

... More
Cable Trays with Earthing: Shall be with Strip earthing as specified in each size of cable tray. Bolted on both sides of the cable tray with provision for jointing the adjoining pieces by means of a additional Piece of strip with holes provided at all ends for the same. Also extra Holes for Tapping. The jointing portion shall be atleast 100 mm il length & shall be raised/away from Main side frame of the Tray to enable Bolting for Jointing & Tappings. The Running meter lengths of cable Trays Shall include all types of standard Joints,"+" "U"; "T”; "L" Horizontal, vertical, Bends etc.Straight, Left hand, Right Hand reducers etc. Horizontal, vertical inside & vertical outside elbows complete with all necessary Hardwares like Nuts Bolts, Plain & Spring washers.

-

-

-

... More
CABLE LADDER

-

-

-

... More
consider 2 mm thickness all ladders trays.

-

-

-

... More
100 X 50 GI LADDER TRAY

-

-

-

... More
150 X 50 GI LADDER TRAY

-

-

-

... More
200 X 50 GI LADDER TRAY

-

-

-

... More
300 X 75 GI LADDER TRAY

-

-

-

... More
600 X 100 GI LADDER TRAY

-

-

-

... More
900 X 100 GI LADDER TRAY

90

-

-

... More
CABLE TRAYS - PERFORATED TYPE

-

-

-

... More
Consider 2 mm thickness for all trays.

-

-

-

... More
50 X 50 mm GI perforated cable tray

609

-

-

... More
100 X 50 mm GI perforated cable tray

150

-

-

... More
150 X 50 mm GI perforated cable tray

150

-

-

... More
200 X 50 mm GI perforated cable tray

-

-

-

... More
300 X 75 mm GI perforated cable tray

25

-

-

... More
450 X 75 mm GI perforated cable tray

-

-

-

... More
600 X 100 mm GI perforated cable tray

-

-

-

... More
900 X 100 mm GI perforated cable tray

-

-

-

... More
CABLE TRAYS COVER

-

-

-

... More
Consider 1.6 mm thickness for all trays covers.

-

-

-

... More
50 x 15 mm GI tray cover

180

-

-

... More
100 x 15 mm GI tray cover

150

-

-

... More
150 x 15 mm GI tray cover

-

-

-

... More
200 x 15 mm GI tray cover

-

-

-

... More
300 X 20 mm GI tray cover

25

-

-

... More
450 X 20 mm GI tray cover

-

-

-

... More
600 X 20 mm GI tray cover

-

-

-

... More
900 X 25 mm GI tray cover

-

-

-

... More
Supply & laying of AL. extruded raceways of various sizes as detailed below including Cutting / chasing of floor and remaking of floor with proper fiinishing for Power & Data cables for work stations.

-

-

-

... More
50 X 38 mm

-

-

-

... More
100 X 38 mm

-

-

-

... More
150 X 38 mm

-

-

-

... More
200 X 38 mm

-

-

-

... More
300 X 38 mm

-

-

-

... More
Supply, installation, testing and commissioning of G.I. readymade type -JUNCTION BOX - 2 MM THICK

-

-

-

... More
75 x75 x 65 mm

-

-

-

... More
150 x 150 x 65 mm

-

-

-

... More
225 x 225 x 65 mm

-

-

-

... More
300 x 300 x 65 mm

-

-

-

... More
Supply, transport, unloading, shifting & Fabrication of steel sections and erection of MS base frames, MS angle channels, flat, MS C-Channel, MS Z-Channel etc for supporting various items of equipment such as various panels/local machine switches / proper cable laying in trenches / addition support for proper cable termination/ MS Fabricated cable trays/ junction boxes/ light fittings, DB etc. The scope include welding, bolting, chipping , grouting etc. The all MS steel assembly should be fabricated in the contractors shop and then HOT- Dip galvanisation of total assembly shall be done. Rate shall include total process of Galvanization and all allied costs. The scope is inclusive of minor civil work as required, supply of GI hardware materials, consumables, tools & tackles and necessary labour.

-

-

-

... More
TOTAL OF SECTION CABLE TRAY

-

-

-

... More
LIGHT FITTINGS

-

-

-

... More
Supply , Installation Testing & commissioning of following type of light fixtures as per drawings and specifications with all other accessories such as supporting rods/ropes/chains / frames, anchor fasteners, necessary hardware etc.(EXCEPT HIGH BAY FITTING) The rate shall include for fittings along with wires, down rods etc. complete with all accessories to complete the installation as required. All fittings should have warrantee of Five years & warrantee cards of all the fittings duly filled with stamp are to be submitted along with Final bill. It will be contractors responsibility to store provide light fitting. Suport the for light fitting from perlin rafter etc with the help of clamp, chain or any other supporting accessories will be in contractors scope.

-

-

-

... More
TYPE OF LED FITTING - SMD TYPE MAKES OF LED • PHILIPS- LUMILED • OSRAM • NICHIA • CREE • SAMSUNG KOREA

-

-

-

... More
LUMINARY WILL BE PROVIDED WITH FOLLOWING PROTECTION • Output over voltage & under voltage Protection • Over temperature • Output over current and short circuit Auto Recovery • Input high voltage cut off Auto Recovery

-

-

-

... More
INDOOR LIGHTING

-

-

-

... More
Supply, Installation ,Testing & Commissioning of 36W LED FULL GLOW SQUARE LIGHT FITTINGS (SUITABLE FOR 600 X 600 Grid CEILING) LUMEN OUTPUT OF LED FITTING - 4200 LUMEN COLOR TEMPERATURE 5500 - 6000 K BEAM ANGLE - 120 DEGREE IP RATING OF LIGHT FITTING - IP 20 AND ABOVE IK RATING- IK 08 AND ABOVE SURGE PROTECTION 2 KV AND ABOVE POWER FACTOR 0.95 TOTAL HARMONIC DISTORTION (THD) 10% COLOUR RENDERING INDEX (CRI) 80

69

-

-

... More
Supply, Installation ,Testing & Commissioning of 40 W LED WELLGLASS FITTING TEMPERATURE 5500 - 6000 K IP RATING OF LIGHT FITTING - IP 65 IK RATING- IK 10 AND ABOVE SURGE PROTECTION 2 KV AND ABOVE POWER FACTOR 0.95 TOTAL HARMONIC DISTORTION (THD) 7% COLOUR RENDERING INDEX (CRI) 80

-

-

-

... More
Supply, Installation ,Testing & Commissioning of 120W LED FLOOD LIGHT FITTING. COLOR TEMPERATURE 5500 - 6000 K IP RATING OF LIGHT FITTING - IP 65 IK RATING- IK 10 AND ABOVE SURGE PROTECTION 2 KV AND ABOVE POWER FACTOR 0.95 TOTAL HARMONIC DISTORTION (THD) 7% COLOUR RENDERING INDEX (CRI) 80

26

-

-

... More
Supply, Installation ,Testing & Commissioning of 28 W LED LINEAR LIGHT FITTINGS INDUSTRIAL GRADE- 1200 MM LENGHT LUMEN OUTPUT OF LED FITTING - 2000 LUMEN COLOR TEMPERATURE 5500 - 6000 K IP RATING OF LIGHT FITTING - IP 65 AND ABOVE IK RATING- IK 08 AND ABOVE SURGE PROTECTION 2 KV AND ABOVE POWER FACTOR 0.95 TOTAL HARMONIC DISTORTION (THD) 10% COLOUR RENDERING INDEX (CRI) 80

-

-

-

... More
Supply, Installation ,Testing & Commissioning of 158 W LED HIGH BAY LIGHT FITTING Suggested Make : Philips BY616P LED250S 5700 NB PSU GR COLOR TEMPERATURE 5500 - 6000 K LUMEN OUTPUT OF LED FITTING - 25000 LUMEN BEAM ANGLE - NARROW BEAM IP RATING OF LIGHT FITTING - IP 65 IK RATING- IK 10 AND ABOVE SURGE PROTECTION 2 KV AND ABOVE POWER FACTOR 0.95 TOTAL HARMONIC DISTORTION (THD) 7% COLOUR RENDERING INDEX (CRI) 80

52

-

-

... More
Supply, Installation ,Testing & Commissioning of 12-18 W LED SURFACE/RECESSED MOUNTED DOWN LIGHT FITTINGS WITH - 150 MM DIA LUMEN OUTPUT OF LED FITTING - 2000 LUMEN COLOR TEMPERATURE 5500 - 6000 K IP RATING OF LIGHT FITTING - IP 65 AND ABOVE IK RATING- IK 08 AND ABOVE SURGE PROTECTION 2 KV AND ABOVE POWER FACTOR 0.95 TOTAL HARMONIC DISTORTION (THD) 10% COLOUR RENDERING INDEX (CRI) 80

26

-

-

... More
Supply, Installation ,Testing & Commissioning of 15-18 W LED Skirting Light Fitting suibtable for installation in outdoor conditions. Scope will also consist of concealed box and termination etc complete.

-

-

-

... More
Supply, Installation ,Testing & Commissioning of 5 Meter High Pole with Bracket on Top, suitable for mounting of Floodhlights. Pole should be hot deep galvanized, with base plate and connection box inside pole with MCB Din Rail and Connector suitable for armoured cable connection.

-

-

-

... More
Supply, Installation ,Testing & Commissioning of 8-10 W LED MIRROR LIGHT FITTING

4

-

-

... More
Supply, Installation ,Testing & Commissioning of 09 W LED SURFACE/RECESSED MOUNTED SQUARE / ROUND LUMINAIRE.

-

-

-

... More
Supply, installation, testing & commissioning of 1200 mm sweep ceiling fan with BLDC Motor & upto 600mm length down rod with canopies.

-

-

-

... More
Supply installation, testing & commissioning of 200 mm sweep exhaust fans with frame & bird protection louvers including all hardware etc. complete as required.

8

-

-

... More
Supply, installation, testing & commissioning of 250mm exhuast fan with frame and bird protection louvers including all hardware etc. complete as required.

-

-

-

... More
Supply, installation, testing & commissioning of heavy duty Single Phase 750mm Air Circulator (Column Mounted) with frame & including all hardware etc. complete as required.

-

-

-

... More
Supply, installation, testing & commissioning of 28/36 Watt Flameproof Battern Light Fitting with Flameproof End Terminations required

2

-

-

... More
Supply, installation, testing & commissioning of EMERGENCY EXIT LIGHT SIGNAGE BOARD & SIGNAGE BOARD FOR STAIRCASE. Fittings should have battery back up for 30 Minutes : Suggsted Make - Prolite

20

-

-

... More
OUTDOOR LIGHTING

-

-

-

... More
Supply, installation ,Testing & Commissioning of 8 mtr. tubular poles SP 22 or equivalent complete including excavation of pole pit in all types of strata except hard rock & 1000 x 450 x 450 mm foundation, couping 2 Nos. 40 mm dia. 1500 mm long GI. pipes bend to shape in foundation for cable entry, cable loop box with 15 A, 4 way connector, 16 A SP MCB, earthing of pole with 8 SWG wire, painting with Primer + 2 coat of paint & bottom with black paint & balance with silver paint.

-

-

-

... More
SINGLE BRACKET

-

-

-

... More
Supply, installation, testing & commissioning of 12M high mast shaft in two sections suitable for 50 m/sec wind speed, with raising lowering system comprising, head frame, luminaries carriage suitable to install 20 nos luminaries in symmetrical arrangement, double drum winch, 6mm diameter SS wire rope, required cable, connector, external power tool electrical motor / winch motor, manual handle, junction box, aviation lamp, lightning protecton rod & including all required accessories. Supply of foundation bolts manufactured from special steel along with nuts, washers, anchor plates and templates including foundation drawing & all required accessories.

3

-

-

... More
Supply, installation, testing & commissioning of following MV panel boards compartmental cubicle type freestanding with appropriate cable entries, front operating, front maintained wherever required complete with base frame etc. as required and as per IS 8623 specifications. Panel has to be fabricated out of 14 / 16 SWG CRCA sheet, and surface treated with phosphating seven tank process and duly powder coated with RAL 7032 or any approved color.

3

-

-

... More
Outdoor stand mounted High-mast Panel with 32A TPN MCB as incomer and single dial time switch with 32A FP contactor for the automatic switching of luminaries and 25A TPN MCB for power tool control including raise-lower push button. (1 set for each high mast)

-

-

-

... More
Supply, installation, testing & commissioning of flood light fixture on Canopies / PEB Cladding at 5 & 8 Mtrs. Height with necessary controlgear, lamp, hardware etc. including cable connection box.

-

-

-

... More
Supply, Installation ,Testing & Commissioning of 200 W LED FLOOD LIGHT FITTING COLOR TEMPERATURE 5500 - 6000 K IP RATING OF LIGHT FITTING - IP 65 IK RATING- IK 10 AND ABOVE SURGE PROTECTION 2 KV AND ABOVE POWER FACTOR 0.95 TOTAL HARMONIC DISTORTION (THD) 7% COLOUR RENDERING INDEX (CRI) 80

18

-

-

... More
TOTAL OF SECTION LIGHT FITTINGS

-

-

-

... More
POINT WIRING

-

-

-

... More
Supply , Installation, Testing and Commissioning of following items with suitable accessories and supports ,accessories, labor etc. for wiring for lights, ceiling fans, exhaust fans, 6A sockets. Rate shall include GI conduit and its accessories in concealed / open conduit /Casing & capping & above false ceiling using pull/junction boxes, light outlet boxes, G.I.Switch outlet boxes, switch plates, 6A/16A one or two way switches, including testing and commissioning complete. The rate for point wiring shall include wiring from first switch point and then looping between the points. The rate shall also include the cost of providing 1no. 1.0 Sqmm PVC insulated copper conductor wire to connect all lights, switches sockets etc.

-

-

-

... More
Primary or One way light points, using 25 mm Dia GI conduit and multi strand FRLS copper conductor wire 1.5 sq. mm. size for phase neutral and earth. point controlled by modular switches (Average Point Length 7 meter). Ceiling flexible PVC / GI conduit shall be included at the drop of light fixture.

48

-

-

... More
Secondary or light point in group, using 25 mm Dia GI conduit and multi strand FRLS copper conductor wire 1.5 sq. mm. size for phase neutral and earth. point controlled by modular switches (Average Point Length 5 meter). Ceiling flexible PVC / GI conduit shall be included at the drop of light fixture.

51

-

-

... More
One way fan points, using 25 mm Dia GI conduit and multi strand FRLS copper conductor wire 1.5 sq. mm. size for phase neutral and earth. Point controlled by modular switches The rate shall also include cost of 300 W electronic fan speed controller in this item only. (Average Point Length 7.5 meter). Rate shall exclude the cost of ceiling fan in this item.

-

-

-

... More
Exhaust points, using 25 mm Dia GI conduit and multi strand FRLS copper conductor wire 1.5 sq. mm. size for phase neutral and earth. Point controlled by modular switches. (Average Point Length 7.5 meter). Rate shall be inclusive of fixing of exhause fan with required accessories.

8

-

-

... More
MCB CONTROL - Primary or One way light points, 25 mm Dia GI conduit andmulti strand FRLS copper conductor wire 1.5 sq. mm. size for phase neutral and earth. Primary light point means extending the wiring till the light fixture with ceiling rose & complete accessories (wiring from the DB to first light is covered under circuit mains) Ceiling flexible GI conduit shall be included at the drop of light fixture. (Average Point Length 7 meter)

-

-

-

... More
MCB CONTROL - Secondary or light point in group, using 25 mm Dia GI conduit and multi strand FRLS copper conductor wire 1.5 sq. mm. size for phase neutral and earth. Secondary light point means extention of light outlet from existing primary point with ceiling rose & complete accessories. Same to be controlled by the existing MCB in DB .Ceiling flexible GI conduit shall be included at the drop of light fixture. (Consider Average length of 5 Mtrs.)

-

-

-

... More
Supply , Installation, Testing and Commissioning of Lighting Occupancy sensor below false ceiling used in office areas and toilet with manual override. .

-

-

-

... More
SOCKET OUTLETS (EXCLUDE WIRING)

-

-

-

... More
Supply and installation of Modular socket for the facility. Please note The color of face plate shall be WHITE for rawpower & BLACK for UPS. Vendor shall quote accordingly.

-

-

-

... More
Supply, Installation of testing and commissioning of modular Single phase 6/16 Amps multi pin flush type socket outlets controlled by 16 A modular switch .The assembly shall be flush mounted in the partition/ wall. (RP)

40

-

-

... More
Supply, Installation of testing and commissioning of on board 6A plug point controlled by 6A modular switch.

10

-

-

... More
Supply, Installation of testing and commissioning of modular Single phase 20 Amps multi pin flush type socket outlets controlled by 20 A modular switch.The assembly shall be flush mounted in the partition/ wall. (RP)

-

-

-

... More
Supply, Installation of testing and commissioning of modular Single phase 6/16 Amps multi pin flush type socket outlets controlled by 6 A modular switch .The assembly shall be flush mounted in the moduler furniture (RP). Kindly consider 16A Switch with indicator for the same.

-

-

-

... More
Supply, Installation of testing and commissioning of modular Single phase 2 nos. Of 6/16 Amps multi pin flush type socket outlets controlled by 2 no.s of 6 A modular switch .The assembly shall be flush mounted in in the partition/ wall. (RP). Kindly consider 16A Switch with indicator for the same.

40

-

-

... More
Supply, Installation of testing and commissioning of 3 NOS. modular Single phase 6/16 Amps multi pin flush type socket outlets controlled by 10 A modular Switch.The assembly shall be flush mounted in the partition/ wall. (UP). Kindly consider 16A Switch with indicator for the same.

40

-

-

... More
Supply, Installation of testing and commissioning of 1 NOS. modular Single phase 6/16 Amps multi pin flush type socket outlets controlled by 6 A modular Switch.The assembly shall be flush mounted in the moduler furniture (UP)

-

-

-

... More
TOTAL OF SECTION POINT WIRING

-

-

-

... More
CIRCUIT MAINS AND POWER WIRING

-

-

-

... More
Supply and drawing of circuit Mains for the point wiring for areas controlled by 6/16 Amps switches and power wiring using 1100V grade PVC insulated multi strand copper conductor wire drawn into GI conduit pipes in concealed / open conduit system with necessary fixing accessories like bends, collars, junction boxes, clamps, spacers, etc., complete. Wiring shall be as per specifications.

-

-

-

... More
2 Runs of 1.5 sqmm + 1 Run of 1.5 sqmm multi strand FRLS copper conductor wire in Existing Raceways/Cabletrays/Conduits. ( Rate Shall exclude Raceways/Cabletrays/Conduits) (For Lighting, Emergency Lighting Ciruit Mains, Modular Sockets Wiring)

450

-

-

... More
2 Runs of 2.5 sqmm + 1 Run of 2.5 sqmm multi strand FRLS copper conductor wire in Existing Raceways/Cabletrays/Conduits. ( Rate Shall exclude Raceways/Cabletrays/Conduits) (For Lighting, Emergency Lighting Ciruit Mains, Modular Sockets Wiring)

550

-

-

... More
2 Runs of 4 sqmm + 1 Run of 4 sqmm multi strand FRLS copper conductor wire in Existing Raceways/Cabletrays/Conduits. ( Rate Shall exclude Raceway / cabletrays)

825

-

-

... More
2 Runs of 6 Sqmm + 1 Run of 6 Sqmm multi strand PVC insulated copper conductor wire in Existing Raceway / cabletrays/ PVC / GI conduit. ( Rate Shall exclude Raceway / cabletrays)

-

-

-

... More
4 Runs of 2.5 sqmm + 1 Run of 2.5 sqmm multi strand FRLS copper conductor wire in Existing Raceways/Cabletrays/Conduits. ( Rate Shall exclude Raceways/Cabletrays/Conduits)

-

-

-

... More
4 Runs of 4 sqmm + 1 Run of 4 sqmm multi strand FRLS copper conductor wire in Existing Raceways/Cabletrays/Conduits. ( Rate Shall exclude Raceway / cabletrays)

-

-

-

... More
Supply and laying of multistranded FRLS copper conductor 3 core x 1.5 sq.mm sheathed flexible cable laid in 25 mm GI conduit / Raceways / Perforated cable trays (P, N & E) with complete all accessories, wiring terminations etc. as per standards & specifications. (Rate shall be excluding of GI conduit / Raceways/ Perforated cable trays)

-

-

-

... More
Supply and laying of multistranded FRLS copper conductor 3 core x 2.5 sq.mm flexible sheathed cable laid in 25 mm GI conduit / Raceways/ Perforated cable trays (P, N & E) with complete all accessories, wiring terminations etc. as per standards & specifications. (Rate shall be excluding of GI conduit / Raceways/ Perforated cable trays)

-

-

-

... More
Supply, installation, testing and commissioning of 25 mm Dia GI conduit for laying wires and cables mentioned in above sections including cost of junction boxes, bends, elbows, sockets, tees etc. laying in slab, cutting chasis and making good or surface mounted including all fixing hardware.

1095

-

-

... More
Supply, installation, testing and commissioning of MMS -32 mm Dia GI conduit for laying wires and cables mentioned in above sections including cost of junction boxes, bends, elbows, sockets, tees etc. laying in slab, cutting chasis and making good or surface mounted including all fixing hardware.

-

-

-

... More
Supply, installation, testing and commissioning of MMS -50 mm Dia GI conduit for laying wires and cables mentioned in above sections including cost of junction boxes, bends, elbows, sockets, tees etc. laying in slab, cutting chasis and making good or surface mounted including all fixing hardware.

-

-

-

... More
Supply, installation, testing and commissioning of 19 mm casing & capping for laying wires and cables mentioned in above sections including cost required accessories . laying on wall/ partitions, surface mounted including all fixing hardware.

-

-

-

... More
Supply, installation, testing and commissioning of 25 mm casing & capping for laying wires and cables mentioned in above sections including cost required accessories . laying on wall/ partitions, surface mounted including all fixing hardware.

-

-

-

... More
Supply, installation, testing and commissioning of PVC Armored Flexibles Conduit 19mm/25mm

-

-

-

... More
TOTAL OF SECTION CIRCUIT MAINS AND POWER WIRING

-

-

-

... More
EARTHING STATIONS

-

-

-

... More
Supply, installation, testing and commissioning of Indelec / OBO / Jef / Actord make eco safe maintenance free electrode of 25 mm diameter low carbon steel with 250 micron molecular copper bonded earthing rod of 3 mtrs. length along with carbon based environment friendly back fill ground enhancing compound required to fill up the excavated earth with required quanitity. It also includes necessary accessories like nuts and bolts, test link, insulators etc. This item includes 100 mm dia drill in ground, average 8 meter depth in back filled earth and 4 meter depth in vergin earth (total average 12 meters depth drill). It also includes suitable casing for the drill upto the backfilled area, installation of earth electrode, supply, installation and connection of earth strip from electrode to test link inclusive of inside the borewell earthing strip upto 9 meter, testing and connection complete as per code of practice IS:3043 complete. (Electrode type) Earthing Instruction Board to be supplied with Earthing for in perodic maintenance date and showing ohm value of particular earth pit

-

-

-

... More
LT PANEL & EQUIPOTENTIAL EARTHING

4

-

-

... More
SCADA EARTHINGS

8

-

-

... More
HIGH MAST EARTHING

3

-

-

... More
UPS EARTHING

4

-

-

... More
LIGHTNING PROTECTION

4

-

-

... More
BONFIRE SHED

2

-

-

... More
OFFICE BUILDING

4

-

-

... More
Supply, tagging, laying or fixing, testing of GI / Cu earthing strip / wire in ground All joints shall have SS nut bolts or with Brazzing

-

-

-

... More
50 X 6 GI EARTHING STRIP

440

-

-

... More
25 X 6 GI EARTHING STRIP

390

-

-

... More
25 X 3 CU EARTHING STRIP

480

-

-

... More
Supply , laying,fixing of suitable section of copper conductor, FRLS WIRE for DBS and Equipmemt. With proper ring type lug at both end.

-

-

-

... More
16 sq. mm. PVC insulated copper wire(Green colour)

225

-

-

... More
10 sq. mm. PVC insulated copper wire.(Green colour)

-

-

-

... More
6 sq. mm. PVC insulated copper wire. (Green colour)

-

-

-

... More
4 sq. mm. PVC insulated copper wire. (Green colour)

-

-

-

... More
Busbar of 0.5 Mtr length made out of 50 x 6 mm GI strip with drill holes of M8 at 25mm interval mounted on insulators with Enclosure.

2

-

-

... More
Busbar of 0.5 Mtr length made out of 25 x 3 mm Cu. strip with drill holes of M8 at 25mm interval mounted on insulators with Enclosure.

2

-

-

... More
TOTAL OF SECTION EARTHING STATIONS

-

-

-

... More
SAFETY DEVICES

-

-

-

... More
Supply , Laying & Fixing of 1.1 kV 12 mm thick Rubber mat of 2 mtr x 1 mtr

15

-

-

... More
Supply , Laying & Fixing of 11 KV 12 mm thick Rubber mat of 2 mtr x 1 mtr

2

-

-

... More
Supply, installation, testing and commissioning of Safety chart

2

-

-

... More
Supply, installation, testing and commissioning of First Aid Kit

2

-

-

... More
Supply of Wooden framed glass fronted shock treatment chart as per IE rules fixed to wall.

2

-

-

... More
Supply & Fixing of Main SLD Laminated with Wooden framed glass SLD must be from Main source up to DB outgoing SLD with as built drawings. This item also includes to provide 4 Nos of hardcopy of as built drawing & 3 Nos of softcopy of as built drawing of all SLD, Lighting,IPS, Switch sockets & whole project SLD in single line diagram acceptable to Engineer Incharge.

2

-

-

... More
TOTAL OF SECTION LIASONING & APPROVALS

-

-

-

... More
LIGHTENING PROTECTION SYSTEM

-

-

-

... More
Supply, Installation, Testing and Commissioning of Conventional Lightning Protection System complying regulations of MSEDCL and CEIG Norms & specifications

-

-

-

... More
Supply, Installation, Testing and Commissioning of FRANKLIN ROD TYPE AIR TERMINAL, lightening protection system. Full electrical continuity between the tip and the earth point. The basic construction includes brass holder and termination arrangement for conductor, 2.5 mtr long copper hollow pipe, brass spindle at top, with 5 spikes bolted to the spindle. Scope should be consist of all supporting this air termination to PEB with required bolting arrangements and fabrication work.

2

-

-

... More
Supply, Installation, Testing and Commissioning of Disconnection link for testing of earth conductivity.

2

-

-

... More
Supply, Installation, Testing and Commissioning of Supporting arrangement for AIR TERMINAL

2

-

-

... More
Supply, Installation, Testing and Commissioning of Test Clamp to connect the down conductor to the earth termination and disconnect the down conductor from the earth termination for regular checks of the earth termination resistance value.

2

-

-

... More
TOTAL OF SECTION LIGHTENING PROTECTION SYSTEM

-

-

-

... More
CIVIL RELATED WORK

-

-

-

... More
Supply & Laying of of ISI standard HDPE / SN4 pipe including cost of conveyance from stores to site of work, cost of jointing material, labour, giving hydraulic testing etc. complete as directed by Engineer-in-charge. crush Sand bedding 75 mm shall be provided below Pipe.

-

-

-

... More
50 mm dia HDPE/SN4 Pipe

-

-

-

... More
100 mm dia HDPE/SN4 Pipe

-

-

-

... More
150 mm dia HDPE/SN4 Pipe

300

-

-

... More
300 mm dia HDPE/SN4 Pipe

600

-

-

... More
Providing and constructing B.B. masonary chamber as per structural design provided by structural consultant with providing and fixing heavy duty Perforated RCC manhole frame and SFRC cover in etc.complete as directed by Engineer-in-charge.

-

-

-

... More
Manholes Size 0.30M X 0.450M - depth 0.8mtr

-

-

-

... More
Manholes Size 0.60M X 0.60M depth 0.8mtr

17

-

-

... More
Manholes Size 0.90M X 0.60M - Depth 0.8m

22

-

-

... More
Soil Excavation :- Earth work in excavation for Electrical Cable trench of required width & chamber work upto 0.8m in depth in all type of soil including ,stone soiling,boulder filling using pickaxes or mechanical means including shoring & dewatering by bailing or by normal pumping if required, dressing section to the required grade,camber,side slopes. ( Measurement based on solid volumn of excavated quantities of specified width as per drawing ) complete as directed

450

-

-

... More
Rock Excavation :-Excavation in all kinds and condition of hard rock up to 0.8 mtr by chiselling or sledging or any other means including shoring & dewatering by bailing or pumping if required preparing the bed of the trench/ chamber to the required grade,camber, side slopes. ( Measurement based on soild volumn of excavated quantities of specified width as per drawing) complete as directed

20

-

-

... More
Sand Bed :-Providing & laying sand bed of 75mm thick in trench. The sand shall be river sand/gravel with size 1 to 10 mm only. Complete as directed.

47

-

-

... More
Soil Filling :- Providing & laying earth work in trench filling with approved murrum or equivalent material available from excavation including spreading in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming & watering,by using mechanical compactor ( Plate or Roller)as approved by engineer so as to attain 95% Standard proctor density,incl. soil testing for compaction etc. complete to required level & slopes as spcified, directed. ( measurement based on soild volumn of filling quantities of specified width as per drawing & levels recorded) .The type of compactor to be used shall be approved by the engineer based on the trial.

305.5

-

-

... More
Disposal of excess material :-Disposal of unwanted materials from excavation at contractor risk & cost to the location suitable to contractor outside working area.

70.5

-

-

... More
PCC 1:3:6: Providing and laying in position plain cement concrete of specified volume proportion including the cost of centring and shuttering - All work upto plinth level to the required level & thickness, consolidation, curing, dewatering if necessary etc. complete.

3

-

-

... More
RCC M-20 grade Design Mix Work for road crossing- Providing and laying in position machine batched, machine mixed (non tilting with automatic water dispenser arrangement) concrete or by RMC (with prior approval) and machine vibrated, designed mix cement concrete as per IS 456-2000 of specified grade for reinforced cement concrete structural elements, including the cost of centring, shuttering, scaffolding, lifting, pouring, finishing, admixtures in recommended proportions as per IS 9103 to accelerate, retard, setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in -charge to required level / shapes / slopes, curing, all lead, lift, depths etc. complete. (including fixing of Reinforcement steel work if required) For M-20 grade Reinforced Cement Concrete for road crossing as per detail specifications and directions-(Only site batching and mixing be allowed).Curing will be in contractor`s scope. The scope also includes providing TMT bars in foundation. Special Notes : 1) Equipment foundations should be as per OEM recommendation.

50

-

-

... More
TOTAL OF SECTION CIVIL RELATED WORK

-

-

-

... More
LIASONING WORK

-

-

-

... More
Liason Work with CEIG ,MIDC with Drawing Approval and precommisioning visit required if any. All statutory compliances including Approvals, Permissions, Sanctions etc. from Electrical Inspectorate office and or any other respective Agencies / Bodies to run the Functions inside and outside the buildings for which they are constructed. All LT Electrical work & Lifts All Statutory charges paid by Contractor on behalf of ARAI shall be reimbursed at actuals on submission of original documents.

1

-

-

... More
TOTAL OF SECTION LIASONING WORK

-

-

-

... More
SUMMARY OF ALL SECTIONS

-

-

-

... More
SOURCES

-

-

-

... More
PANELS

-

-

-

... More
READYMADE DISTRIBUTION BOARD

-

-

-

... More
CABLES AND END TERMINATION

-

-

-

... More
CABLE TRAY

-

-

-

... More
LIGHT FITTINGS

-

-

-

... More
POINT WIRING

-

-

-

... More
CIRCUIT MAINS AND POWER WIRING

-

-

-

... More
EARTHING STATIONS

-

-

-

... More
SAFETY DEVICES

-

-

-

... More
LIGHTENING PROTECTION SYSTEM

-

-

-

... More
CIVIL RELATED WORK

-

-

-

... More
LIASONING WORK

-

-

-

... More
TOTAL AMOUNT OF WORK

-

-

-

... More
GST (AT ACTUAL)

-

-

-

... More
GRAND TOTAL AMOUNT INCLUDING TAX

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.