Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.

Automotive Research Association Of India - ARAI Tender

Works
Eprocure
Opening Date28 Nov 2024
Closing Date18 Dec 2024
Tender AmountRefer Documents 
Notes
Download

Costs

Summary

Supply,installation,testing And Commissioning Of Hvac System For Cylinder Test

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply, Installation, Testing & Commissioning of VRV/ VRF Indoor Units of following types complete with Evaporator Cooling Coil, Blower with Blower Motor, Electronic Expansion Valve, Drain Pump, Inbuilt Controller for communication with the main microprocessor in the out door unit, Corded and Cordless Remote Controller Facility, Necessary Refrigerant Piping with necessary interlocks. Cordless remote shall be include with the IDU.

-

-

-

... More
Ceiling Mount Cassette type machines ( 4 way Type)

-

-

-

... More
Min 2 TR, Air flow min 950 CFM

2

-

-

... More
Min 3 TR, Air flow min 1400 CFM

3

-

-

... More
Supply, Installation, Testing & Commissioning of Copper Refnet Joints for the VRV/ VRF Indoor Units as per the site layout requirements and as per the manufacturers design standard requirements.

4

-

-

... More
Supply, Installation, Testing & Commissioning of Outdoor Units Stands fabricated out of Mild Steel (MS) 'C' Channel Section for VRV/ VRF (18 HP) of minimum 75mm x 50mm x 5mm thick size complete with minimum 300mm long legs made of the same 'C' channel with 8mm thick MS Plate at the bottom of the legs. The MS Plate should be minimum 150mm x 150mm. 2 Layered 10mm thick Ribbed Rubber Pads with 24 Gauge GI Shim in-between shall be installed below the Condenser Stand Legs.

-

-

-

... More
Min. 16 HP

1

-

-

... More
Supply, Installation, Testing & Commissioning of Control Cabling of recommended size by OEM between VRV/ VRF Indoor & Outdoor Units. The Control Cable used shall be minimum Sheathed multistrand cable, properly protected in a GI Conduit with proper Junctions, end Flexible connections of 300mm for final connections with the Indoor Units with proper Glands etc.,

40

-

-

... More
SITC of GI ladder type cable tray 200 mm wide with GI Cover for supporting refrigerant piping, cabling in shafts / terrace, complete with supports.

40

-

-

... More
Supply cabling with 3-pin top o f 16 Amps& flexible conduit to connect IDU power supply. Cables & accessories to be ISI marked. Average 1.8 m long.

5

-

-

... More
Cable of respective size recommended by OEM from Isolator to ODU with earthing & terminations. This cable should be armoud with proper cladding and gland termination.

-

-

-

... More
Min. 14 HP

6

-

-

... More
Supply, installation, testing and commissioning of refrigerant Suction & liquid piping using eddy current free Copper pipes and fittings like elbows, couplers, tee joints, brass fittings, "U" loops, expansion loops etc. Supports consisting of GI box / "C" sections & female anchor fasteners with full threaded GI rods, insulation of pipes using 13 mm thick elastomeric closed cell Nitrile Rubber insulation material having class "O" for fire properties, structural clamps with hard PVC pipe sleeves under the clamps to protect insulation at supports, tagging to enable tracing connectivity to respective units as per shop drawings to be generated by contractor and approved by consultant. Submission of test reports in approved format forms a part of this item scope. Making up of any leakages occurring during testing / commissioning / first calendar year from handing over, including supply, labour, consumables, refrigerant, top up, oil top up and incidental expenses also forms a part of the scope covered under this item.

110

-

-

... More
Supply, Installation, Testing & Commissioning of PVC - SCHEDULE 40 Drain Piping complete with proper fittings (Elbows, Bends, Tees etc.,) properly installed using GI Slotted Channel / GI Split Clamp Supports. All joints to be properly sealed using SOLVENT CEMENT and allowing a resting period of 24 Hrs for every sealed joint to ensure proper fusion. (Finolex / Equivalent Make Only). The Drain Piping should be properly Insulated with 9mm/10mm thick Nitrile Rubber Insulation.

-

-

-

-

-

-

80

-

-

36

-

-

... More
SITC of underdeck insulation with 30mm Nitride rubber with class O Fire alongwith aluminum foil on outer side of insulation. The insulation shall be stuck into slab using bitumins as adhesive and clamped/screwed using GI wire and . The clamping shall be done at each corner and Centre of the sheet.

195

-

-

... More
SITC of inverter type Cassette AC with indoor & Outdoor, copper condenser, Green gas, L Type Outdoor stand, cordless remote and including drilling/core cutting, filling of gap etc. all hardware/fittings required for its installation with following sizes.

-

-

-

... More
Min 3TR

3

-

-

... More
Min 2.5TR

3

-

-

... More
Min 2TR

1

-

-

... More
Supply, Installation, Testing & Commissioning of Power Cabling of recommended size by OEM between Indoor & Outdoor Units. The Cable should be properly protected in a GI Conduit with proper Junctions, end Flexible connections of 300mm for final connections with the Indoor Units with proper Glands etc.,

70

-

-

... More
Ventilation System

-

-

-

... More
SITC of 25 mm thick Double skin Air Washer Unit complete with intake louvers, 20 micron washable filters with mounting frame, 300 mm thick cellulose pad sections 304 Water sump with spray pump- 02Nos ( 01R+01S) & piping, 4 pass drift eliminator, Min 2Nos DIDW blower with IE3 Motor, outlet Flexible connection, Outdoor type provision, Anti Vibration Pad, Water Drain & Inlet valve etc.

-

-

-

... More
Min Capacity 45000 CFM With 80 MMWC SP

1

-

-

... More
SITC of Inline Cabinet fan for Fresh air with capacity of 9000CFM with inlet fan , 20MM WC alogwith all hardware like tie rod, anchor fastener, MS Supporting if any on the wall

1

-

-

... More
SITC of wall mounted Electrical Control Panel for fresh air Unit with 2mm MS CRC Sheet, Inlet filters, Cooling fans, 02 Nos Earthing Provision, All switch gear, Relay, Pushbutton, Indicators, On/Off switch with LOTO Provisions, Volt Meter, Ampere Meter etc.

1

-

-

... More
SITC of Factory made GI Rectangular/Circular ducting with MS Chanel/Angle supporting, flange gasket. Earthing link, 2 Coat primer and 02coat enamel paint with necessary accessories required for installation at site.

-

-

-

... More
24 Gauge

-

-

-

... More
22 Gauge

650

-

-

... More
20 Gauge

40

-

-

... More
SITC of Acoustic Insulation with 40mm thick insulation from inside the duct for outside duct exposed outside the building.

81

-

-

... More
SITC of nitrile rubber 13 mm Insulation With UV Coating for outside exposed ducting, 26swg Aluminum cladding complete with hardware etc.

81

-

-

... More
SITC of Volume Control damper for Airwasher ducting of GI Construction at outlet of air washer.

3

-

-

... More
SITC of Aluminum powder coated Jet Diffuser with damper. Sound level should be below 60Dba inside the lab area.

30

-

-

... More
SITC of Canvass connection for Airwasher, fans & ducting alongwith Hardware etc.

2

-

-

... More
SITC of Electrical Control Panel for Air washer Units with 2mm MS CRC Sheet, MS Stand, Inlet filters, Cooling fans, 02 Nos Earthing Provision, All switch gear, Relay, Pushbutton, Indicators, On/Off switch with LOTO Provisions, Volt Meter, Ampere Meter etc.

1

-

-

... More
SITC of Armoud Copper Cabling with earthing as per the OEM recommended size for AHU panel to AHU along with earthing cable, Glands, Lug etc.

60

-

-

... More
SITC of 2mm GI Perforated cable tray with Cover, Earthing link, MS Support with complete installation at site of size 150x50 etc.

60

-

-

... More
SITC of Exhaust fan with capacity of 500cfm, 20mm WC alongwith cowl piece, bird net, MS Frame etc

3

-

-

... More
SITC of electrical panel for 03 nos fan along with ON/OFF push button, indication lamp, cabling from panel to fans, earthing, inlet filter, cooling fan etc.

1

-

-

... More
Design, Supply, Installation, testing & Commissioning of High Volume Low speed fan for the Shed 01 area of 55x20Mtr- 03Nos fan & Shed-02 Size 20x13- 01NMos fan. Min Size of each fan shall be 24 Feet Major Scope: Fan hanging frame for upper and lower side, Direct Drive Fan Motor, Hub & Fan Blade, Guy Wire, Control panel with VFD, All switch gear in the panel for fan, Cables, Cable tray with cover, Earthing cables. The scope shall be includes all hardware for its installation. ARAI Shall provide the electrical connection to equipment control panel only.

-

-

-

... More
24 Feet Diameter Fan

4

-

-

-

-

-

... More
L1 to be evaluated on basic cost

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.