Airports Authority Of India Tender
... More
Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.
Airports Authority Of India - AAI Tender
Electrical and Electronics
Electrical Works
GEM
Opening Date22 Jan 2025
Closing Date13 Feb 2025
Tender Amount₹ 1,17,71,713
Costs
EMD
₹ 1,99,521Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
GEM/2025/B/5832947Tender No
GEM/2025/B/5832947Tender Authority
Airports Authority Of India ViewPurchaser Address
-Website
http://bidplus.gem.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Inspection servicing overhauling repair testing setting of existing 11 KV switchgear having 06 Nos. 800A rating VCB by the OEM or their authorised service providers as per OEM's standard recommendations, practices including providing all conumables, submitting test reports, complete checking & testing of all control wiring, attending unlimited breakdown, complaint call & ensure serviceability etc. as per direction of Engineer-In-Charge.
2
-
-
... More
Inspection servicing overhauling repair testing setting of existing 1.1 KV grade upto 2500 Amps rating LT Air Circuit Breakers (ACB) of different makes like ABB, L&T, Schneider, Siemens etc. by any OEM of LTACB or their authorised service provider as per OEM's standard recommendations, practices including providing all conumables, submitting test reports, complete checking & testing of all control wiring, attending unlimited breakdown, complaint call & ensure serviceability etc. as per direction of Engineer-In-Charge.
86
-
-
... More
Calibration of various types of electromagenetic /static /numerical relays installed in existing 11 KV VCB panels, LT panels by secondary current injection method including inspection, servicing, testing, repairs, settings, tripping test of circuit breaker, secondary circuit checking, rectification (if required), attending unlimited breakdown, complaint and submission of test reports as per standard practice and direction of Engeneer-In-Charge.
02 or 03 overcurrent + 01 earth fault relay
18
-
-
... More
Earth fault relay
12
-
-
... More
Inspection and maintenance of 1500 KVA Dry type 11 KV/433 volt Distribution transformers by OEM or their authorised service providers as per OEM's standard recommendations, practices including cleaning by vacuume cleaner / blower, tightnings of HV and LV side cable terminals, control connections, earth connections, checking and testing of all protective, field protection relays connected with the transformer, insulation resistance checking, attending unlimited breakdown, complaint call, submission of report etc. complete as per direction of Engeneer-In-Charge.
6
-
-
... More
Replacement including supply of front cover of LT air circuit breaker of different makes like ABB, Schneider, L&T, Siemens etc. suitable for site .
5
-
-
... More
Replacement testing commissioning including supply of following coils suitable for existing unserviceable LT ACB of different make like ABB, L&T, Schneider, Siemens etc. to make it serviceable upto the satisfaction of Engineer-In-Chargeas as when required.
Closing coil
-
-
-
... More
Tripping Coil
-
-
-
... More
Under voltage release coil
-
-
-
... More
Spring Charging motor
-
-
-
... More
Arc Chute
-
-
-
... More
Circuit Breaker Auxiliary Contact
-
-
-
... More
Solenoid Coil
3
-
-
... More
Replacement testing commissioning including supply of 400A rating following model contactor suitable for the site including wiring, interconnection, all required retrofitting accessories etc. to ensure smooth operation of the associated switchgear up to the satisfaction of Engineer-In-Charge and dismantling of the existing contactor, shifting it to AAI store etc. complete as required.
Make: ABB, Model A260-30 or equivalent.
-
-
-
... More
Replacement testing commissioning including supply of 10 HP, 10m-24.5m head range, 2130 LPM- 840 LPM discharge capacity, 415V 3-ph 50Hz dewatering pump with driving motor, impeller, coupler, starter panel etc. including suitable foundation on MS angle frame, connection with existing suction and discharge line by providing required reducers, flanges, gaskets, nuts, bolts, interconnection etc. and dismantling of existing pump, shifting it to AAI store complete as per site requirement and as directed by Engineer-In-Charge.
Make: Kirloskar, Model: SP-4LA+ or equivalent.
-
-
-
... More
Replacement testing commissioning including supply of 5 HP, 10m-18m head range, 17 LPS- 3.5 LPS discharge capacity, 415V 3-ph 50Hz dewatering pump with driving motor, impeller, coupler, starter panel etc. including suitable foundation on MS angle frame, connection with existing suction and discharge line by providing required reducers, flanges, gaskets, nuts, bolts, interconnection etc. and dismantling of existing pump, shifting it to AAI store complete as per site requirement and as directed by Engineer-In-Charge.
Make: Kirloskar, Model: SP-3L+M or equivalent.
-
-
-
... More
Replacement testing commissioning including supply of 3 HP, 9m-23m head range, 9 LPS- 2 LPS discharge capacity, 415V 3-ph 50Hz dewatering pump with driving motor, impeller, coupler, starter panel etc. including suitable foundation on MS angle frame, connection with existing suction and discharge line by providing required reducers, flanges, gaskets, nuts, bolts, interconnection etc. and dismantling of existing pump, shifting it to AAI store complete as per site requirement and as directed by Engineer-In-Charge.
Make: Kirloskar, Model: SP-2HM or equivalent.
-
-
-
... More
Replacement testing commissioning including supply of 2HP 1-ph 230V 50Hz dewatering submerssible pump including connection, discharge pipe line of suitable size etc. complete as required.
Make: KSB, Model: AMAPORTER503 SE or equivalent.
-
-
-
... More
Replacement testing commissioning including supply of following digital meter by replacing existing meter including connection, making suitable cutout and/or fixing metal blanking plate if necessary etc. complete as required as per the direction of Engineer-In-Charge.
Digital multifunction meter of 415 V, 50 Hz, 3 Phase, 5A, class 1.0
Make Schneider Conzerv, Model No. EM6400NG+ or Equivalent.
5
-
-
... More
Digital voltmeter 415V 3-phase class 0.5
-
-
-
... More
Digital ammeter class 0.5, 1/5A, 3-phase
-
-
-
... More
Replacement testing commissioning including supply of extended rotating mechanism of different make, rating for following switchgears as and when required including panel cutting & making hole (if required), screw, nut etc. to ensure smooth operation of the switchgears under closed condition of the panel door complete as required.
(i)MCCB
-
-
-
... More
(ii) ACB
2
-
-
... More
Replacement testing commissioning including supply of suitable type TNC (Trip-Nutral-Close) handle (2 trip + 2close) in existing LT, HT panel including wiring, expert manpower, tools etc. to operate the ACB/VCB through the TNC handle complete as required.
-
-
-
... More
Replacement testing commissioning including supply of voltage monitoring relay (VMR) at existing panel as and when required & ensure smooth operation of associated ACB upto the satisfaction of Engineer-In-Charge. Make: PROTON, Model: VMR 3P or equivalent.
-
-
-
... More
Replacement setting testing commissioning including supply of 800SQ-A-230 analog time switches etc. complete as required.
-
-
-
... More
Replacement testing commissioning including supply of follwing MCCB Ics=Icu on the existing LT panel including making whole, fixing screw, nut, bolts, adjusting interconnecting links with busbar, cable if required, dismentalling of existing MCCB and handing over the same to AAI store etc. complete as per site requirement & directed by Engineer-In-Charge on as and when required basis.
63 Amp 4 Pole MCCB, Breaking capacity 36 kA
-
-
-
... More
125 Amp 4 Pole MCCB, Breaking capacity 36 kA
-
-
-
... More
160 Amp 4 Pole MCCB, Breaking capacity 36 kA
-
-
-
... More
250 Amp 3 Pole MCCB, Breaking capacity 36 kA
-
-
-
... More
250 Amp 4 Pole MCCB, Breaking capacity 36 kA
-
-
-
... More
400 Amp 3 Pole MCCB, Breaking capacity 36 kA
-
-
-
... More
400 Amp 4 Pole MCCB, Breaking capacity 36 kA
-
-
-
... More
Replacement testing commissioning including supply of CGI14C relay or better model in existing 11kV switchgear panel by dismantiling existing protective relay and handing over to AAI including proper wiring, primary injection, submission of test report, training to AAI staffs etc. complete as per the site requirement and as directed by Engineer-In-Charge.
-
-
-
... More
Replacement laying including supply of XLPE insulated & PVC sheathed following size aluminium conductor , armoured cable of 1.1 KV grade confirming to IS- 7098 ( Part-I) with up to date ammendements etc. complete as & when required & directed by Engineer-In-Charge.
4 C x 25 sq.mm.
-
-
-
... More
Fabrication and supply of stainless steel board with suitable SS stand of overall height of 4 ft (approx.) showing encrypted message in black color "WORK IN PROGRESS, SORRY FOR INCONVINIENCE" or as directed by Engineer-In-Charge including transportation etc. complete as required.
-
-
-
... More
Replacement testing commissioning including supply of DOL starter for 3-ph 5HP dewatering pump motor set including connection, fixing on wall with screws, nuts, washer etc. complete as required and dismantling of existing starter, shifting it to AAI store.
-
-
-
... More
Replacement testing commissioning including supply of Star-Delta starter for 3-ph 12.5HP dewatering pump motor set including connection, fixing on wall with screws, nuts, washer etc. complete as required and dismantling of existing starter, shifting it to AAI store.
-
-
-
... More
Replacement testing commissioning including supply of Panel cooling fans of reputed make working on 230V 50 Hz AC supply, having durablility & long life as and when required up to the satisfaction of Engineer-In-Charge.
-
-
-
... More
Replacement testing commissioning including supply of 750mm sweep, 1500 rpm appx heavy duty air circulator Pedestal Fans (wall/floor mounted) working on 230V 50 Hz AC supply as and when required up to the satisfaction of Engineer-In-Charge.
-
-
-
... More
Calibration of various types of Current Tranformers/Potential transformers installed in existing 11 KV VCB panels, LT panels by primary current/voltage injection method including inspection, servicing, testing, repairs, settings, polarity testing, insulation testing, rectification (if required), attending unlimited breakdown, complaint and submission of test reports as per standard practice and direction of Engeneer-In-Charge.
20
-
-
... More
Carrying out Fogging/spray treatment for mosquitoes/pests in power house through mechanical fogging methods as & when directed by Engineer-In-Charge.
8
-
-
... More
Annual maintenance of NASU Make CCRs (2 Nos. 7.5 KW, 2 Nos. 4 KW) i/c repairing of defective CCRs by identifying the fault, repairing of defective PCB's and other components and service the same, i/c calibration of CCRs and complete checking, servicing on as & when required basis by carrying out OEM Visit & submission of necessary reports etc. (1 Visit includes servicing & repair of all 4 Nos. CCRs)
2
-
-
... More
Note:- All quoted Rates must be inclusive of GST
-
-
-